MONTHYEARML12251A1222012-09-0707 September 2012 Acceptance Review E-mail - Relief Request C-2 for the Reactor Pressure Vessel Leak-Off Flange, Third 10-Year Inservice Inspection Interval Project stage: Acceptance Review ML12345A1882012-12-10010 December 2012 Request for Additional Information E-mail - Relief Request C-2 for the Reactor Pressure Vessel Leak-Off Flange, Third 10-Year Inservice Inspection Interval Project stage: RAI ML13025A2612013-01-0909 January 2013 Enclosure to TXX-13003 Drawings for Response to RAI Question 2 Project stage: Response to RAI CP-201300002, Response to Request for Additional Information for Unit 1 Relief Request No. C-22013-01-0909 January 2013 Response to Request for Additional Information for Unit 1 Relief Request No. C-2 Project stage: Response to RAI ML13046A3852013-03-19019 March 2013 Relief Request C-2 for the Reactor Pressure Vessel Flange Leak-Off Piping, Third 10-Year Inservice Inspection Interval Project stage: Other CP-201301199, Relief Request No. C-3 for the Unit 2 Reactor Pressure Vessel leak-off Flange (Second ISI Interval Start Date: August 3, 2004; Second ISI Interval End Date: August 2, 20142013-10-31031 October 2013 Relief Request No. C-3 for the Unit 2 Reactor Pressure Vessel leak-off Flange (Second ISI Interval Start Date: August 3, 2004; Second ISI Interval End Date: August 2, 2014 Project stage: Request ML13350A6302013-12-16016 December 2013 NRR E-mail Capture - Acceptance Review for Relief Request C-3 for Comanche Peak Unit 2, - TAC No. MF2997 Project stage: Acceptance Review ML14007A0002014-01-0303 January 2014 NRR E-mail Capture - Request for Additional Information (RAI) - Relief Request (RR) C-3 - TAC No. MF2997 Project stage: RAI CP-201400070, Response to Request for Additional Information for Relief Request No. C-3 for Unit 2 Reactor Pressure Vessel Leak-off Flange (Second ISI Interval Start Date: August 3, 2004; Second ISI Interval End Date August 2, 2014)2014-01-23023 January 2014 Response to Request for Additional Information for Relief Request No. C-3 for Unit 2 Reactor Pressure Vessel Leak-off Flange (Second ISI Interval Start Date: August 3, 2004; Second ISI Interval End Date August 2, 2014) Project stage: Response to RAI ML14030A4662014-01-30030 January 2014 NRR E-mail Capture - Follow-up Request for Additional Information for Relief Request C-3 - TAC MF2997 Project stage: RAI CP-201400144, Clarification to Response to Request for Additional Information for Relief Request No. C-3 for Unit 2 Reactor Pressure Vessel Leak-Off Flange (Second ISI Interval Start Date: August 3, 2004; Second ISI Interval End.2014-02-11011 February 2014 Clarification to Response to Request for Additional Information for Relief Request No. C-3 for Unit 2 Reactor Pressure Vessel Leak-Off Flange (Second ISI Interval Start Date: August 3, 2004; Second ISI Interval End. Project stage: Supplement ML14084A2912014-04-0404 April 2014 Relief Request No. C-3 for Reactor Pressure Vessel Leak-Off Flange for the Second 10-Year Inservice Inspection Interval Project stage: Other CP-201500157, Relief Request No. 2C3-1 for the Reactor Pressure Vessel Leak-Off Flange (Third ISI Interval Start Date: August 3, 2014; Third ISI Interval End Date: August 2, 2023)2015-02-24024 February 2015 Relief Request No. 2C3-1 for the Reactor Pressure Vessel Leak-Off Flange (Third ISI Interval Start Date: August 3, 2014; Third ISI Interval End Date: August 2, 2023) Project stage: Request 2013-03-19
[Table View] |
|
---|
Category:E-Mail
MONTHYEARML24025A0172024-01-22022 January 2024 NRC Request for Concurrence with Endangered Species Act Determinations for Comanche Peak License Renewal, Issuance of Draft Supplemental Environmental Impact Statement, and Opportunity for Public Comment ML24019A0742024-01-19019 January 2024 NRR E-mail Capture - Comanche Peak - Draft Request for Additional Information - License Amendment Request to Extend the Allowed Outage Time for an Inoperable Emergency Diesel Generator ML24008A2492023-12-18018 December 2023 Texas Shpo Response for Comanche Peak Deis Review and Comment ML23311A2202023-11-20020 November 2023 NRC to Fws, NRC Request for Concurrence with Endangered Species Act Determinations for Comanche Peak License Renewal, Issuance of Draft Supplemental Environmental Impact Statement, and Opportunity for Public Comment (Consultation Code: 2023 ML23255A2882023-09-12012 September 2023 NRR E-mail Capture - Comanche Peak - Acceptance of Request for Exemption from 10 CFR 50.71(e)(4) Final Safety Analysis Update Schedule ML23256A1492023-09-11011 September 2023 Email from Mark Yoo (NRC) to Ken Peters (Vistra) - Comanche Peak LRA - Request for Additional Information - Set 4 ML23226A0072023-08-11011 August 2023 NRR E-mail Capture - Comanche Peak 1 and 2 Audit Plan - License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors ML23188A0442023-07-0707 July 2023 Email from Mark Yoo (NRC) to Ken Peters (Vistra) - Comanche Peak LRA - Request for Additional Information - Set 3 ML23181A0722023-06-29029 June 2023 NRR E-mail Capture - Comanche Peak - Acceptance of License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors ML23181A0202023-06-29029 June 2023 Email from Mark Yoo (NRC) to Ken Peters (Vistra) - Comanche Peak LRA - Request for Additional Information - Set 2 ML23172A0152023-06-20020 June 2023 NRR E-mail Capture - Re Comanche Peak - Acceptance of License Amendment Request Regarding General Design Criterion 5 of Appendix a to 10 CFR Part 50 and Regulatory Guide 1.81 ML23167A0222023-06-14014 June 2023 Email: Request for Additional Information (RAI) Letter for the Review of the Comanche Peak Initial License Renewal Application, Set 1 ML23145A2332023-05-25025 May 2023 Email from Mark Yoo (NRC) to Ken Peters (Vistra) - Comanche Peak LRA - Request for Confirmation of Information - Set 2 ML23143A1382023-05-23023 May 2023 Email from Mark Yoo (NRC) to Ken Peters (Vistra) - Comanche Peak LRA - Request for Confirmation of Information - Set 1 ML23139A0802023-05-18018 May 2023 NRR E-mail Capture - Comanche Peak Draft Supplemental Information Request - License Amendment Request Regarding General Design Criterion 5 of Appendix a to 10 CFR Part 50 and Regulatory Guide 1.81 ML23138A1522023-05-18018 May 2023 Lr Docs - (External_Sender) Comanche Peak Nuclear Power Plants ML23135A9132023-05-15015 May 2023 NRR E-mail Capture - Comanche Peak - Draft Supplemental Information Request - License Amendment Request to 10 CFR 50.69 ML23131A2932023-05-11011 May 2023 Lr Docs - License Renewal for Comanche Peak Nuclear Power Plant, Units 1 and 2 ML23128A1612023-05-0808 May 2023 NRR E-mail Capture - Comanche Peak Nuclear Power Plant, Units 1 and 2, Beaver Valley Power Station, Unit Nos. 1 and 2, Davis-Besse Nuclear Power Station, Unit 1, and Perry Nuclear Power Plant, Unit No. 1 - Acceptance of Requested Licensing ML23110A7122023-04-20020 April 2023 NRR E-mail Capture - Comanche Peak - Verbal Authorization of Proposed Alternative RV-1 (L-2023-LLR-0019) ML23103A4682023-04-11011 April 2023 NRR E-mail Capture - Comanche Peak Request for Additional Information - License Amendment Request to Apply the Westinghouse Full Spectrum Loss of Coolant Accident Evaluation Model ML23086B9852023-03-27027 March 2023 NRR E-mail Capture - Comanche Peak Draft Request for Additional Information - Request to Apply the Westinghouse Full Spectrum Loss of Coolant Accident Evaluation Model ML23061A1612023-03-0202 March 2023 E-mail from David Griggs Regarding Submission to NRC Electronic Information Exchange on 03/01/2023 for Citizens for Fair Utility Regulation in Comanche Peak Proceeding ML23032A3842023-02-0101 February 2023 LRA On-Site Audit Needs List ML23214A0192023-01-30030 January 2023 (External_Sender) Request to Broaden Extended Deadline to the General Public (with Attachments) - C3 ML23214A0202023-01-29029 January 2023 (External_Sender) Requesting a Deadline Extension on NRC-2002-0183, Comanche Peak License Renewal - C2 ML23214A0182023-01-26026 January 2023 (External Sender) NRC-2022-0183-0003 (with Attachment) - C6 ML23214A0162023-01-24024 January 2023 (External Sender) EPA Scoping Comment Letter for the Comanche Peak Nuclear Power Plant License Renewal (with Attachment) - C8 ML23214A0142023-01-23023 January 2023 (External Sender) Docket NRC-2022-0183 Comanche Peak Nuclear Power Plant Renewal (with Attachment) - C1 ML23214A0172023-01-17017 January 2023 (External Sender) NRC License Extension? No! ML23214A0132023-01-17017 January 2023 (External Sender) Docket Id NRC-2022-0183, Request for Extension of License for Comanche Peak, Comment for Environmental Scoping - C9 ML23214A0122023-01-13013 January 2023 (External Sender) Correction to Comment Submitted 01-13-23 - C11 ML22362A0992022-12-28028 December 2022 NRR E-mail Capture - Comanche Peak - Acceptance of License Amendment Request to Apply Westinghouse Fsloca Evaluation Model ML22362A0972022-12-28028 December 2022 NRR E-mail Capture - Comanche Peak - Acceptance of License Amendment Request to Adopt WCAP-17661-P-A, Revision 1, Improved RAOC and CAOC Fq Surveillance Technical Specifications, ML22325A2742022-11-21021 November 2022 NRR E-mail Capture - Comanche Peak - Request for Additional Information - Proposed Alternative P-1 Regarding IST of Safeguards Building Sump Pumps ML22318A3102022-11-10010 November 2022 NRR E-mail Capture - Comanche Peak - Draft Request for Additional Information - Proposed Alternative P-1 Regarding IST of Safeguards Building Sump Pumps ML22237A2842022-08-25025 August 2022 CPNPP 2022 EP Program Inspection RFI Hjs 08252022 ML22230B1092022-08-17017 August 2022 NRR E-mail Capture - Comanche Peak Unit 2 - Request for Additional Information - 2RE19 Inspection Summary Report for Steam Generator Tubing ML22229A0792022-08-17017 August 2022 NRR E-mail Capture - Comanche Peak - Acceptance of Requested Licensing Action - Proposed Alternative P-1 Regarding IST of Safeguards Building Sump Pumps ML22220A1942022-08-0808 August 2022 NRR E-mail Capture - Comanche Peak Unit 2 - Draft Request for Additional Information - 2RE19 Inspection Summary Report for Steam Generator Tubing ML22133A0472022-05-13013 May 2022 July 2022 Emergency Preparedness Exercise Inspection - Request for Information ML22083A0262022-03-23023 March 2022 NRR E-mail Capture - Comanche Peak - Request for Additional Information - Request to Adopt TSTF 505 Revision 2 ML22031A2122022-01-31031 January 2022 NRR E-mail Capture - Comanche Peak - Acceptance of Requested Licensing Action - Proposed Alternative to Extend the Snubber Inservice Program Third Interval ML21300A1342021-10-27027 October 2021 NRR E-mail Capture - Comanche Peak Units 1 and 2 - License Amendment Request to Adopt TSTF-505 - Audit Plan Update and Audit Questions (L-2021-LLA-0085) ML21286A7912021-10-13013 October 2021 NRR E-mail Capture - Comanche Peak - Request for Additional Information - Request to Adopt TSTF-577 Revision 1 ML21272A2002021-09-29029 September 2021 NRR E-mail Capture - Comanche Peak Unit 2 - Upcoming Steam Generator Tube Inservice Inspection (L-2021-NFO-0013) ML21270A1632021-09-27027 September 2021 NRR E-mail Capture - Comanche Peak - Acceptance of Quality Assurance Program Change Request Regarding Internal Audit Frequency ML21253A2242021-09-0909 September 2021 Request for Information Occupational Radiation Safety Inspection (71124.01, 71124.02, and 71151) from 10/18-22/2021 ML21252A0062021-08-26026 August 2021 NRR E-mail Capture - Comanche Peak - Acceptance of License Amendment Request Regarding Adoption of TSTF-577, Revised Frequencies for Steam Generator Tube Inspections 2024-01-22
[Table view] |
Text
NRR-PMDAPEm Resource From: Singal, Balwant Sent: Friday, January 03, 2014 7:59 AM To: Hope, Timothy' (Timothy.Hope@luminant.com)'
Cc: Jack.Hicks@luminant.com' (Jack.Hicks@luminant.com)'
Subject:
Request for Additional Information (RAI) - Relief Request (RR) C TAC No. MF2997 Attachments: MF2997-RAIs.docx
- Tim, By letter dated October 31, 2013 (Agencywide Documents Access and Management Systems (ADAMS) Accession No. ML13312A121), Luminant Generation Company LLC (the licensee) submitted for the U.S. Nuclear Regulatory Commission (NRC) approval relief request (RR) C-3 for Comanche Peak Nuclear Power Plant (CPNPP), Unit 2. The licensee proposed an alternative to a certain requirement of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code),Section XI. RR C-3 relates to the inservice inspection (ISI) requirement of IWC-5220 of the ASME Code,Section XI, for the system leakage test of the reactor pressure vessel (RPV) flange leak-off piping.
The NRC staff issued the Draft RAIs on December 24, 2013. The NRC staff was informed by you via e-mail on January 2, 2014 that a clarification call is not needed. You are requested to provide your response to the attached RAIs within 30 days from the date of this e-mail. Please treat the attached RAI as a formal request.
Thanks.
Balwant K. Singal Senior Project Manager (Comanche Peak and STP)
Nuclear Regulatory Commission Division of Operating Reactor Licensing Balwant.Singal@nrc.gov Tel: (301) 415-3016 Fax: (301) 415-1222 1
Hearing Identifier: NRR_PMDA Email Number: 986 Mail Envelope Properties (192BB59294514E41B5305C3C82867608013DE93B7F4F)
Subject:
Request for Additional Information (RAI) - Relief Request (RR) C TAC No.
MF2997 Sent Date: 1/3/2014 7:59:24 AM Received Date: 1/3/2014 7:59:00 AM From: Singal, Balwant Created By: Balwant.Singal@nrc.gov Recipients:
"Jack.Hicks@luminant.com' (Jack.Hicks@luminant.com)'" <Jack.Hicks@luminant.com>
Tracking Status: None
"Hope, Timothy' (Timothy.Hope@luminant.com)'" <Timothy.Hope@luminant.com>
Tracking Status: None Post Office: HQCLSTR02.nrc.gov Files Size Date & Time MESSAGE 1283 1/3/2014 7:59:00 AM MF2997-RAIs.docx 70434 Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date:
Recipients Received: ZZZ
REQUEST FOR ADDITIONAL INFORMATION REQUEST FOR ALTERNATIVE C-3 REGARDING SYSTEM LEAKAGE TEST OF REACTOR PRESSURE VESSEL FLANGE LEAK-OFF PIPING LUMINANT GENERATION COMPANY LLC COMANCHE PEAK NUCLEAR POWER PLANT, UNIT 2 DOCKET NUMBER 50-446 By letter dated October 31, 2013 (Agencywide Documents Access and Management Systems (ADAMS) Accession No. ML13312A121), Luminant Generation Company LLC (the licensee) submitted for the U.S. Nuclear Regulatory Commission (NRC) approval relief request (RR) C-3.
The licensee proposed an alternative to a certain requirement of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code),Section XI. RR C-3 relates to the inservice inspection (ISI) requirement of IWC-5220 of the ASME Code,Section XI, for the system leakage test of the reactor pressure vessel (RPV) flange leak-off piping. The licensee submitted the request for the Comanche Peak Nuclear Power Plant (CPNPP), Unit 2.
The NRC staff requests the following additional information.
- 1. The NRC requires deviations from the ASME Code,Section XI, be pre-approved in accordance with Title 10 of the Code of Federal Regulations (10 CFR) 50.55a(a)(3)(ii).
The licensee submitted RR C-3 for the second 10-year ISI interval which commenced on August 3, 2004, and will end on August 2, 2014. The RPV flange leak-off piping is subject to a system leakage test each inspection period in accordance with the ASME Code,Section XI. Please discuss whether the system leakage tests have been performed in accordance with the ASME Code,Section XI, IWC-5220, in the previous inspection period(s) of the second 10-year ISI interval. If the answer is No, please discuss the reason(s) for not obtaining the NRC prior-authorization for deviation from the requirement in the previous inspection period(s) of the second 10-year ISI interval. If the answer is Yes, please discuss why the required test cannot be performed in the current inspection period of the second 10-year ISI interval.
- 2. Could the subject piping be pressurized and inspected at the beginning of a refueling outage before removing the RPV head? Please discuss the hardship and potential personnel radiation exposure for performing the system leakage test in accordance with the ASME Code,Section XI, IWC-5220. The NRC staff notes that the licensee addressed this question in the Request for Additional Information response dated January 9, 2013 (ADAMS Accession No. ML130250339) for the CPNPP, Unit 1, as a supplement to the request for RR C-2 dated August 23, 2012 (ADAMS Accession No. ML12250A670). Please state if the licensees response for CPNPP, Unit 1 be applicable to CPNPP, Unit 2?