MONTHYEARML13155A4222013-05-29029 May 2013 Environmental Report, Part 1 Project stage: Request ML13155A4232013-05-29029 May 2013 Environmental Report, Part 2 Project stage: Request ML13154A2182013-05-29029 May 2013 License Renewal Boundary Drawings Project stage: Other ML13175A0722013-07-31031 July 2013 Noi, Federal Register Notice Project stage: Request ML13184A1102013-08-0505 August 2013 Notice of Intent to Prepare an Environmental Impact Statement and Conduct Scoping Process for License Renewal for the Byron Station Unit Nos. 1 and 2 (Tac Nos. MF1834 and MF1835) Project stage: Other ML13227A2492013-08-16016 August 2013 License Renewal Process and Environmental Scooping Meeting Project stage: Meeting ML13266A1832013-08-20020 August 2013 Public Scoping Meeting for the Byron Nuclear Station License Renewal Application Transcript - Afternoon Session Project stage: Meeting ML13266A1822013-08-20020 August 2013 Public Scoping Meeting for the Byron Nuclear Station License Renewal Application Transcript - Evening Session Project stage: Meeting ML13275A0402013-08-20020 August 2013 License Renewal Process and Environmental Scoping Meeting Slides Project stage: Meeting ML13261A1642013-08-21021 August 2013 0821NRC-154-Evening Project stage: Request ML13248A2712013-08-21021 August 2013 Comment (3) by Sue Rezin Supporting Extension of Braidwood Nuclear Generating Station License Project stage: Request ML13247A0092013-08-27027 August 2013 Comment (1) of Nancy Schultz Voots & Lawrence M. Walsh on Behalf of the County Board Will County, Illinois Supporting of the Renewal of the Operating License of the Exelon Generation Braidwood Nuclear Generating Station Project stage: Request ML13263A2192013-08-28028 August 2013 Comment (2) of Tom Zimmer Opposing Braidwood Nuclear Plant License Extension for 20 Years Due to Environmental and Health Issue Hazardous Project stage: Request ML13269A3692013-09-0404 September 2013 Comment (00004) of Anne E. Haaker, on Behalf of Il, Historic Preservation Agency, on License Renewal for Braidwood Station Project stage: Other ML13247A5412013-09-0505 September 2013 0821NRC2-154-Afternoon Project stage: Request ML13241A4442013-09-0606 September 2013 Open House-Agenda-Websites Handout Project stage: Request ML13231A0602013-09-10010 September 2013 Environmental Site Audit Regarding Byron Station, Units 1 and 2 Project stage: Other ML13274A2392013-09-16016 September 2013 Comment (6) of Kent Collier on Behalf of Kickapoo Tribe of Oklahoma Supporting the Renewal Application of Braidwood Station, Units 1 & 2 License Project stage: Other ML13263A2212013-09-16016 September 2013 Comment (1) of Kim P. Gouker on Behalf of Ogle County, Illinois Supporting the License Renewal Application of the Byron Power Generating Station Project stage: Other ML13269A3732013-09-24024 September 2013 Comment (00005) of Shawn Cirton, on Behalf of Us Fish and Wildlife Service, on Notice of Intent to Prepare an Environmental Impact Statement for Exelon Generation Company, LLC, License Renewal Application for Braidwood Station, Units 1 and Project stage: Request ML13246A4342013-09-27027 September 2013 Meeting Summary of Public Scoping Meetings Conducted Related to the Review of the Braidwood Station, Unit 1 and 2, License Renewal Application Project stage: Meeting ML13277A3052013-09-27027 September 2013 Comment (00007) of David Kraft on Behalf of Nuclear Energy Information Service on Generic Environmental Impact Statement for License Renewal Application for Braidwood Station, Units 1 and 2 Project stage: Request ML13277A3062013-09-27027 September 2013 Comment (2) of David Kraft on Behalf of Neis Re Supplement to NRCs Generic Environmental Impact Statement for License Renewal for the Byron Nuclear Power Station Project stage: Supplement ML13270A0692013-10-0404 October 2013 Audit Report Project stage: Other ML13240A2342013-10-0404 October 2013 8/10/2013 - Summary of Public Scoping Meetings Conducted Related to the Review of the Byron Nuclear Station, License Renewal Application(Tac Nos. MF1790 and MF1791) Project stage: Meeting ML13270A1162013-10-29029 October 2013 License Renewal Environmental Site Audit Re Byron and Braidwood Stations - Severe Accident Mitigation Alternative (TAC Nos. MF1834/1835, MF1790/1791, MF1832/1833, and MF1792/1793) Project stage: Other ML13270A1262013-11-0707 November 2013 License Renewal Environmental Site Audit Regarding Braidwood Station (TAC Nos. ME1832/1833, MF1792/1793) Project stage: Other ML13318A2382013-12-0303 December 2013 Summary of Site Audit Related to the Review of the License Renewal Application for Braidwood Station, Units 1 and 2 (TAC Nos. MF1832, MF1833, and MF1792, MF1793 Project stage: Approval ML13312A3172013-12-13013 December 2013 Audit Trip Report SAMA Project stage: Other ML13354B9372013-12-20020 December 2013 RAI Braidwood Nuclear Station Project stage: RAI ML13350A5122013-12-20020 December 2013 Request for Additional Information for the Review of the Braidwood Nuclear Stations License Renewal Application - Environmental Audit Project stage: RAI ML13318A2082014-01-0606 January 2014 Request for Additional Information for the Review of the Byron and Braidwood Application - Severe Accident Mitigation Alternative Review (TAC Nos. MF1790, MF1791, MF1792, & MF1793) Project stage: RAI ML14013A3392014-01-13013 January 2014 Environmental RAIs - 1 Supplemental Request Project stage: RAI ML14007A2402014-01-23023 January 2014 SAMA RAI Conference Call Summary Project stage: RAI RS-14-033, Response to NRC Requests for Additional Information for the Severe Accident Mitigation Alternatives Review, Dated January 6, 2014 License Renewal Application2014-02-0404 February 2014 Response to NRC Requests for Additional Information for the Severe Accident Mitigation Alternatives Review, Dated January 6, 2014 License Renewal Application Project stage: Response to RAI ML14050A1012014-03-0404 March 2014 Summary of Telephone Conference Call Held on February 12, 2014, Between the U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC, Concerning Requests for Additional Information Pertaining to the Braidwood Station License Re Project stage: RAI ML13281A5372014-04-0303 April 2014 Issuance of Environmental Scoping Summary Report Associated with the Staffs Review of the Application by Exelon Generation Company, LLC, for Renewal of the Operating Licenses for Braidwood Station, Units 1 and 2, (TAC No. MF1832, MF1833, Mf Project stage: Approval ML14092A3562014-04-15015 April 2014 Summary of Telephone Conference Call Held on March 31, 2014 Between the U.S. NRC and Exelon Generation Company, LLC, Concerning Requests for Additional Information Pertaining to the Braidwood Station, License Renewal Application Project stage: RAI ML14085A1102014-04-30030 April 2014 Summary of Telephone Conference Call Held on March 24, 2014 Between the U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC, Concerning Requests for Additional Information Pertaining to the Braidwood Station, License Renew Project stage: RAI ML13337A5032014-04-30030 April 2014 Issuance of Environmental Scoping Summary Report Associated with the Staffs Review of the Application by Exelon Generation Company, LLC, for Renewal for Braidwood Station, Units 1 and 2 Project stage: Approval ML14114A6712014-05-0101 May 2014 Summary of Telephone Conference Call Held on April 16, 2014, Between the U.S. Nuclear Regulatory Commission & Exelon Generation Company, LLC, Concerning Requests for Additional Information Pertaining to the Braidwood Station, License Renewa Project stage: RAI ML14104B1312014-05-0505 May 2014 Schedule Revision for Environmental Review of Byron and Braidwood Nuclear Stations License Renewal Application - Environmental Review Schedule Project stage: Approval ML14041A3342014-05-28028 May 2014 Issuance of Environmental Scoping Summary Report Associated with the Staffs Review of the Byron Nuclear Station, Units 1 and 2, License Renewal Application Project stage: Approval ML14296A1762014-10-30030 October 2014 Safety Evaluation Report with Open Items Related to the License Renewal of Byron Station, Units 1 and 2, and Braidwood Station, Units 1 and 2 Project stage: Approval ML14220A3822014-11-0505 November 2014 Illinois Environmental Protection Agency Letters on Clean Water Act Section 401 Certification and NRC Review of the Byron and Braidwood License Renewal Application Project stage: Approval ML14338A1242014-12-23023 December 2014 Notice of Availability of the Draft Plant Specific Supplement 54 to the Generic Environmental Impact Statement for License Renewal of Nuclear Plants Regarding Byron, Units 1 and 2, Project stage: Draft Other ML14338A1282014-12-23023 December 2014 FRN for Notice of Availability of the Supplement 54 to the GEIS for License Renewal of Nuclear Plant Regarding Byron, Units 1 and 2 Project stage: Other ML14351A1612014-12-24024 December 2014 Notice of Availability of the Draft Plant-Specific Supplement 54 to the Generic Environmental Impact Statement for License Renewal of Nuclear Plants Regarding Byron, Units 1 and 2, Project stage: Draft Other ML14357A0422014-12-31031 December 2014 NUREG-1437 - Supp 54, Draft Generic Environmental Impact Statement for License Renewal of Nuclear Plants Regarding Byron Station, Units 1 and 2. Project stage: Draft Other ML15008A4422015-01-29029 January 2015 Schedule Revision for the Review of the Byron and Braidwood Stations, Units 1 and 2, License Renewal Application Project stage: Approval 2013-09-04
[Table View] |
Text
Mr. Michael P. Gallagher UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 December 13, 2013 Vice President Nuclear Licensing Projects Exelon Generating Company, LLC 200 Exelon Way Kennett Square, PA 19348
SUBJECT:
AUDIT REPORT REGARDING THE BYRON AND BRAIDWOOD STATIONS, LICENSE RENEWAL APPLICATION (TAC NOS. MF1834, MF1835, MF1790, MF1791, MF1792, MF1793, MF1832, AND MF1833) - SAMA
Dear Mr. Gallagher:
By letter dated May 29, 2013, Exelon Generating Company, LLC (Exelon), submitted an application pursuant to Title 10 of the Code of Federal Regulations Part 54 (10 CFR Part 54), to renew the operating license for Byron and Braidwood Station for review by the U.S. Nuclear Regulatory Commission (NRC or the staff). On November 6, 2013, the NRC audit team completed the regulatory audit of Severe Accident Mitigation Alternatives (SAMA) analysis used in the license renewal application. The audit report is enclosed.
If you have any questions, please contact Tam Tran at 301-415-3617 or by e-mail at Tam. Tran@nrc.gov.
Sincerely,
~
... 1~
Tam Tran, Project Manager Projects Branch 2 Division of License Renewal Office of Nuclear Reactor Regulations Docket Nos. 50-454, 50-455, 50-456, and 50-457
Enclosure:
As stated cc w/encl: See next page
ML13312A317
- concurrence by email OFFICE PM:RPB1 :DLR LA:DLR BC:AADB:DRA BC:RPB2:DLR PM:RPB2:DLR NAME TTran YEdmonds JDozier*
DDrucker TTran DATE 12/13/13 12/13/13 12/12/13 12/13/13 12/13/13
SUBJECT:
AUDIT REPORT REGARDING THE BYRON AND BRAIDWOOD STATIONS, LICENSE RENEWAL APPLICATION (TAC NOS. MF1834, MF1835, MF1790, MF1791, MF1792, MF1793, MF1832, AND MF1833) - SAMA DISTRIBUTION:
HARD COPY:
DLR RF E-MAIL:
PUBLIC RidsNrrDir Resource RidsNrrDirRpb1 Resource RidsNrrDirRpb2 Resource RidsNrrDirRerb Resource RidsNrrDirRarb Resource RidsNrrDirRasb Resource NRR_DLR_RERB Distribution tam. tran@ nrc.gov lois. james@ nrc.gov john.daily@ nrc.gov lindsay. robinson@ nrc.qov david. wrona@ nrc.gov brian. wittick@ nrc.gov mitzi. young@ nrc.gov anita.ghosh@ nrc.gov christine.england@ nrc.gov Nancy. ranek@ exeloncorp.com
Docket Nos:
License Nos:
Licensee:
Facility:
Location:
Dates:
Approved By:
U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION DIVISION OF RISK ASSESSMENT 50-454, 50-455, 50-456, and 50-457 NPF-37, NPF-66, NPF-72, and NPF-77 Exelon Generation Company, LLC Byron and Braidwood Stations Exelon Offices Kennett Square, Pennsylvania November 4-6, 2013 Jerry Dozier, Chief Accident and Dose Branch (AADB)
Division of Risk Assessment Office of Nuclear Reactor Regulation ENCLOSURE
AUDIT REPORT Subject Bryon/Braidwood Station License Renewal Application Severe Accident Mitigating Alternatives (SAMA) Analysis When November 4, 2013 10:30 am to 5 pm November 5, 2013 8:30 am to 5 pm November 6, 2013 8:30 am to1 :30 pm Location Exelon Generating Company offices, Kennett Square, Pennsylvania Participants John Parillo Bob Schmidt Steve Short*
Bruce Schmidt*
Chris Wilson AI Fulvio**
Nancy Ranek Greg Krueger**
Don Macleod Eric Thornsbury Alex Duval**
Jeff Gabor**
Michael Koenemann NRC NRC/PNNL NRC/PNNL NRC/PNNL Exelon/License Renewal Exelon/License Renewal Exelon/License Renewal Exelon/ Corporate PRA ERIN Engineering ERIN Engineering ERIN Engineering ERIN Engineering DTE Energy (Fermi - Observer)
- Participated part time via conference call.
Documents Reviewed "Byron/Braidwood Self-Assessment", BB PRA-016, Rev. 2, October 17, 2012 "Seismic Walkdown Report In Response to the 50.54(f) Information Request Regarding Fukushima Near-Term Task Force Recommendation 2.3: Seismic for the Byron Station, Unit 1 ".
Appendix G. Report Number 1200108.20-R-001. Rev. 1. Correspondence No.: RS-12-161.
"Braidwood Fire Modeling Report", Rev. 4, January 15, 2009 "Byron Fire Modeling Analysis", Rev. 0, September 22, 2009
Discussion After a welcome and introductions the schedule, plans and logistics for the audit were discussed. The purpose of the audit was to provide the opportunity for the NRC staff and the Exelon staff involved in the SAMA review and preparation to discuss various issues raised by the NRC staff during its initial review of the Byron and Braidwood license renewal application.
The goal of the audit was for the NRC staff to provide an initial identification of the issues for which further information will be needed and to assist Exelon in understanding the specific information desired by the NRC staff. The discussions covered the following general topics all relative to the SAMA analysis:
- 1. the Level 1 internal Events Probabilistic Risk Assessment (PRA)
- 2. the Level 2 PRA accident phenomenology model
- 3. the treatment of external events
- 4. the Level 3 PRA consequences analysis
- 5. the identification and screening of potential SAMAs
- 6. the cost benefit analysis of SAMAs
- 7. potential lower cost alternative SA MAs The RAis as a result of the Byron and Braidwood SAMA audit and review, will be issued in a separate letter.