UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 May 1, 2014 LICENSEE: Exelon Generation Company, LLC FACILITY: Braidwood Station, Units 1 and 2
SUBJECT:
SUMMARY
OF TELEPHONE CONFERENCE CALL HELD ON APRIL 16,2014, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND EXELON GENERATION COMPANY, LLC, CONCERNING REQUESTS FOR ADDITIONAL INFORMATION PERTAINING TO THE BRAIDWOOD STATION LICENSE RENEWAL APPLICATION ENVIRONMENTAL REPORT (TAG NOS. MF1832, MF1833, MF1792, AND MF1793)
The U.S. Nuclear Regulatory Commission and representatives of Exelon Generation Company, LLC, held a telephone conference call on April 16, 2014, to discuss (a) clarification needed for the staff to respond to Illinois Environmental Protection Agency comments regarding Clean Water Act Section 401 certification for the Braidwood Station (Braidwood), Units 1 and 2, license renewal, and (b) updated Table 9.1-1 and 9.1-2 of the Braidwood License Renewal Environmental Report. The telephone conference call clarified the possible need for follow-up RAis. provides a listing of the participants and Enclosure 2 contains a brief description of the discussion and response for the items.
The applicant had an opportunity to comment on this summary.
11::~,
Project Branch 2 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-456 and 50-457
Enclosures:
- 1. List of Participants
- 2. List of Discussion Items cc w/encls: See next page
May 1, 2014 LICENSEE: Exelon Generation Company, LLC FACILITY: Braidwood Station, Units 1 and 2
SUBJECT:
SUMMARY
OF TELEPHONE CONFERENCE CALL HELD ON APRIL 16, 2014, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND EXELON GENERATION COMPANY, LLC, CONCERNING REQUESTS FOR ADDITIONAL INFORMATION PERTAINING TO THE BRAIDWOOD STATION LICENSE RENEWAL APPLICATION ENVIRONMENTAL REPORT (TAC NOS. MF1832, MF1833, MF1792, AND MF1793)
The U.S. Nuclear Regulatory Commission and representatives of Exelon Generation Company, LLC, held a telephone conference call on April16, 2014, to discuss (a) clarification needed for the staff to respond to Illinois Environmental Protection Agency comments regarding Clean Water Act Section 401 certification for the Braidwood Station (Braidwood), Units 1 and 2, license renewal and (b) updated Table 9.1-1 and 9.1-2 of the Braidwood License Renewal Environmental Report. The telephone conference call clarified the possible need for follow-up RAis. provides a listing of the participants and Enclosure 2 contains a brief description of the discussion and response for the items.
The applicant had an opportunity to comment on this summary.
IRA!
Tam Tran, Project Manager Project Branch 2 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-456 and 50-457
Enclosures:
1 List of Participants 2 List of Discussion Items cc w/encls: ListServ DISTRIBUTION: See next page ADAMS Accessi on No* .. ML14114A671 *concurred via email OFFICE LA:DLR:RPB2 PM:DLR:RPB2 BC:DLR:RPB2 PM:DLR:RPB NAME YEdmonds nran BWittick nran DATE 4125114 4125114 4130114 511114 OFFICIAL RECORD COPY
TELEPHONE CONFERENCE CALL REGARDING REQUESTS FOR ADDITIONAL INFORMATION BRAIDWOOD STATION, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION ENVIRONMENTAL REPORT LIST OF PARTICIPANTS APRIL 16, 2014 PARTICIPANTS AFFILIATIONS Tam Tran Nuclear Regulatory Commission (NRC)
William Ford NRC Kevin Folk NRC Nancy Martinez NRC Nancy Ranek Exelon Generation Company, LLC (Exelon)
Albert Fulvio Exelon ENCLOSURE 1
TELEPHONE CONFERNCE CALL REGARDING REQUESTS FOR ADDITIONAL INFORMATION BRAIDWOOD STATION, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION ENVIRONMENTAL REPORT APRIL 16, 2014 The U.S. Nuclear Regulatory Commission {NRC) staff and representatives of Exelon Generation Company, LLC, held a telephone conference call on April16, 2014, to discuss and clarify the two items described below.
- Clarification needed for the staff to respond to Illinois Environmental Protection Agency comment regarding Clean Water Act Section 401 Discussion: The staff explained that Exelon should follow up with Illinois Environmental Protection Agency (I EPA) to obtain proof of water quality certification under Section 401 of the Clean Water Act for the Braidwood Station (Braidwood), Units 1 and 2, license renewal. The I EPA comment can be found in the NRC's Agencywide Documents Access and Management Systems (ADAMS) under ADAMS Accession No. ML13207A105. Exelon indicaled lhal1t understood the clarification needed.
- Updated Table 9.1-1 and 9.1-2 of the Braidwood License Renewal Environmental Report Discussion: Exelon clarified that an updated Table 9.1-1 and 9.1-2 will be submitted as a supplement to the Braidwood License Renewal Environmental Report.
ENCLOSURE 2
SUBJECT:
SUMMARY
OF TELEPHONE CONFERENCE CALL HELD ON APRIL 16,2014, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND EXELON GENERATION COMPANY, LLC, CONCERNING REQUESTS FOR ADDITIONAL INFORMATION PERTAINING TO THE BRAIDWOOD STATION LICENSE RENEWAL APPLICATION ENVIRONMENTAL REPORT (TAC NOS. MF1832, MF1833, MF1792, AND MF1793)
DISTRIBUTION EMAIL:
PUBLIC RidsNrrDir Resource RidsNrrDirRpb1 Resource RidsNrrDirRpb2 Resource RidsOgcMaiiCenter RidsNrrPMBraidwood Resource IT ran BWittick LRobinson JDaily DMclntyre, OPA EDuncan, Rill JBenjamin, Rill AGarmoe, Rill JMcGhee, Rill JRobbins, Rill VMitlyng, Rill PChandrathil, Rill