CY-BY-1 70-301 Revision 8 Level 3 - Information Use OFFSITE DOSE CALCULATION MANUAL FOR BYRON STATION UNITS 1 AND 2 REVISION 8 JUNE, 2012

CY-BY-1 70-301 Revision 8 ODCM TABLE OF CONTENTS PART I - RADIOLOGICAL EFFLUENTS 1.0 D E FIN IT IO N S.......................................................................................

1.1-1 3.11 RADIOLOGICAL EFFLUENTS AND RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM...................................

1.3-1 3.13 METEOROLOGICAL MONITORING PROGRAM................................

1.3-2 4.0 B A S E S...................................................................................

............. 1.4-1 5.0 ADMINISTRATIVE REQUIREMENTS..................................................

1.5-1 PART II - ODCM

1.0 INTRODUCTION

- ODCM GENERAL INFORMATION......................

11.1-1 1.1 Structure of the ODCM.............................................................

11.1-1 1.2 R egulations...............................................................................

11.1-2 1.2.1 Code of Federal Regulations..........................................

11.1-2 1.2.2 Radiological Effluent Technical Standards.....................

11.1-5 1.2.3 Offsite Dose Calculation Manual....................................

11.1-5 1.2.4 Overlapping Requirements.............................................

11.1-5 1.2.5 Dose Receiver Methodology..........................................

11.1-6 1.3 Offsite Dose Calculation Parameters......................................

11.1-10 1.4 R eferences..............................................................................

11.1-10 2.0 INSTRUMENTATION AND SYSTEMS................................................

11.2-1 2.1 Liquid Effluent System Description...........................................

11.2-1 2.1.1 Release Tanks...............................................................

11.2-1 2.1.2 Turbine Building Fire and Oil Sump...............................

11.2-1 2.1.3 Condensate Polisher Sump............................................

11.2-1 2.2 Liquid Effluent Radiation Monitors............................................

11.2-2 2.2.1 Liquid Radwaste Effluent Monitor...................................

11.2-2 2.2.2 Station Blowdown Monitor..............................................

11.2-2 2.2.3 Reactor Containment Fan Cooler (RCFC) and Essential Service Water (SX) Outlet Line Monitor.......... 11.2-2 2.2.4 Turbine Building Fire and Oil Sump Monitor................... 11.2-2 2.2.5 Condensate Polisher Sump Monitor...............................

11.2-2 2.2.6 Component Cooling Water Monitors..............................

11.2-2 2.3 Liquid Radiation Effluent Monitors Alarm and Trip S etpo ints...................................................................................

11.2 -3 2.3.1 Station Blowdown Monitor..............................................

11.2-3 2.3.2 Liquid Radwaste Effluent Monitor...................................

11.2-3 2.3.3 Other Liquid Effluent Monitors........................................

11.2-5 2.3.4 Conversion Factors........................................................

11.2-6 Page 1 of 7

CY-BY-170-301 Revision 8 PART II - ODCM 2.3.5 Allocation of Effluent from Common Release P o ints.............................................................................

11.2 -6 2.3.6 Solidification of Wastes/Process Control P rogram.........................................................................

11.2-6 2.4 Gaseous Effluent System Description.......................................

11.2-6 2.4.1 Waste Gas Holdup System............................................

11.2-6 2.4.2 Ventilation Exhaust Treatment System..........................

11.2-6 2.5 Gaseous Effluent Radiation Monitors........................................

11.2-7 2.5.1 Auxiliary Building Vent Effluent Monitors........................

11.2-7 2.5.2 Containment Purge Effluent Monitors............................

11.2-7 2.5.3 Waste Gas Decay Tank Monitors...................................

11.2-8 2.5.4 Gland Steam and Condenser Air Ejector M o nito rs.........................................................................

11.2 -8 2.5.5 Radwaste Building Ventilation Monitor...........................

11.2-8 2.6 Gaseous Effluent Monitor Alarm and Trip Setpoints................. 11.2-8 2.6.1 Auxiliary Building Vent Effluent Monitors........................

11.2-8 2.6.2 Containment Purge Effluent Monitors............................

11.2-9 2.6.3 Waste Gas Decay Tank Effluent Monitors......................

11.2-9 2.6.4 Gaseous Effluent Release Limits...................................

11.2-9 2.6.5 Release Mixture...........................................................

11.2-10 2.6.6 Conversion Factors......................................................

11.2-10 2.6.7 HVAC Dilution Flow Rates...........................................

11.2-10 2.6.8 Allocation of Effluents from Common Release P o ints...........................................................................

11.2 -10 2.6.9 Dose Projections for Batch Releases...........................

11.2-10 3.0 LIQUID EFFLUENTS...........................................................................

11.3-1 3.1 Liquid Effluent Releases - General Information........................

11.3-1 3.2 Liquid Effluent Concentrations..................................................

11.3-2 3.3 Liquid Effluent Dose Calculation Requirements........................

11.3-4 3.4 Dose Methodology....................................................................

11.3-4 3.5 Site Specific Dose Factors and Bioaccumulation Facto rs......................................................................................

11.3-7 4.0 GASEOUS EFFLUENTS.....................................................................

11.4-1 4.1 Gaseous Effluents - General Information.................................

11.4-1 4.2 Gaseous Effluents - Dose and Dose Rate Calculation Requirements............................................................................

11.4-2 4.2.1 Instantaneous Dose Rates.............................................

11.4-2 4.2.2 Time Averaged Dose from Noble Gas...........................

11.4-5 4.2.3 Time Averaged Dose from Non-Noble Gas Radionuclides.................................................................

11.4-9 Page 2 of 7

CY-BY-1 70-301 Revision 8 PART II - ODCM 5.0 TOTAL DOSE......................................................................................

11.5-1 5.1 Total Dose Calculation Requirements.......................................

11.5-1 5.1.1 Total Effective Dose Equivalent Limits, 10CFR20 and 40CFR190...............................................................

11.5-1 5.1.2 ISFSI.............................................................................

11.5-1 5.1.3 Total Dose Calculation Methodology..............................

11.5-2 5.2 Onsite Radwaste and Rad Material Storage Facilities.............. 11,5-2 5.2.1 Process W aste Storage Facilities...................................

11.5-2 5.2.2 DAW Storage Facilities..................................................

11.5-2 5.2.3 Replaced Steam Generator Storage Facilities............... 11.5-3 5.2.4 ISFSI Facilities...............................................................

11.5-3 5.3 Methodology.............................................................................

11.5-3 5.4 Total Dose................................................................................

11.5-4 5.5 Compliance to Total Dose Limits..............................................

11.5-4 5.5.1 Total Effective Dose Equivalent Limit - 10CFR20 Compliance....................................................................

11.5-4 5.5.2 Dose to a Member of the Public in the Unrestricted Area...........................................................

11.5-4 5.5.3 Dose to a Member of the Public in the Restricted Area...........................................................................

11.5-5 5.5.4 Total Dose Due to the Uranium Fuel Cycle (40CFR190)...................................................................

11.5-5 5.6 W hen Compliance Assessment is Required.............................

11.5-6 6.0 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM..........................................................................................

11.6-1 Page 3 of 7

CY-BY-1 70-301 Revision 8 ODCM TABLE OF CONTENTS LIST OF TABLES PART I - RADIOLOGICAL EFFLUENTS Table 1-a Frequency Notations...............................................................

1.1-4 Table 1-b Compliance Matrix...................................................................

1.1-5 PART II - ODCM Table 1-1 Regulatory Dose Limit Matrix.................................................

11.1-7 Table 1-2 Dose Assessment Receivers.................................................

11.1-8 Table 1-3 Miscellaneous Dose Assessment Factors:

Environmental Parameters...................................................

11.1-17 Table 1-4 Stable Element Transfer Data..............................................

11.1-18 Table 2-1 Liquid Radioactive Effluent Monitors....................................

11.2-11 Table 2-2 Gaseous Radioactive Effluent Monitors...............................

11.2-12 Table 2-3 Assumed Composition of the Byron Station Noble Gas E ff luent.................................................................................

11.2 -13 Table 2-4 Assumed Composition of the Byron Station Liquid E ff lue nt.................................................................................

11.2 -14 Table 3-1 Site Specific Potable Water Dose Factors for Adult Age G ro up.....................................................................................

11.3-9 Table 3-2 Site Specific Potable Water Dose Factors for Teen Age G ro up...................................................................................

11.3 -11 Table 3-3 Site Specific Potable Water Dose Factors for Child Age G ro up...................................................................................

11.3 -13 Table 3-4 Site Specific Potable Water Dose Factors for Infant Age G ro up...................................................................................

11.3 -15 Table 3-5 Site Specific Fish Ingestion Dose Factors for Adult Age G ro up...................................................................................

11.3-17 Table 3-6 Site Specific Fish Ingestion Dose Factors for Teen Age G ro up...................................................................................

11.3 -19 Table 3-7 Site Specific Fish Ingestion Dose Factors for Child Age G ro up...................................................................................

11.3-2 1 Table 3-8 Bioaccumulation Factors (BFj) to be used in the Absence of Site-Specific Data..............................................

11.3-23 Table 4-1 X/Q and D/Q Maxima at or Beyond the Unrestricted Area Boundary.....................................................................

11.4-20 Table 4-2 X/Q and D/Q Maxima at or Beyond the Restricted Area B oundary..............................................................................

11.4-2 1 Table 4-3 Maximum Offsite Gamma-X/Q..............................................

11.4-22 Table 4-4 X/Q and D/Q at the Nearest Resident Locations within 5 m iles.....................................................................................

11.4 -23 Page 4 of 7

CY-BY-1 70-301 Revision 8 ODCM TABLE OF CONTENTS LIST OF TABLES PART II - ODCM Table 4-5 X/Q and D/Q at the Nearest Cow Milk Locations within 5 m iles.....................................................................................

11.4 -24 Table 4-6 X/Q and D/Q at the Nearest Cow Meat Locations within 5 m iles..................................................................................

11.4 -25 Table 4-7 Ground Plane Dose Factors.................................................

11.4-26 Table 4-8 External Dose Factors for Standing on Contaminated G ro und.................................................................................

11.4 -2 8 Table 4-9 Adult Inhalation Dose Factors..............................................

11.4-31 Table 4-10 Teen Inhalation Dose Factors..............................................

11.4-33 Table 4-11 Child Inhalation Dose Factors..............................................

11.4-35 Table 4-12 Infant Inhalation Dose Factors.............................................

11.4-37 Table 4-13 Adult Vegetation Dose Factors.............................................

11.4-39 Table 4-14 Teen Vegetation Dose Factors.............................................

11.4-41 Table 4-15 Child Vegetation Dose Factors.............................................

11.4-43 Table 4-16 Adult Grass-Cow-Milk Dose Factors....................................

11.4-45 Table 4-17 Teen Grass-Cow-Milk Dose Factors....................................

11.4-47 Table 4-18 Child Grass-Cow-Milk Dose Factors....................................

11.4-49 Table 4-19 Infant Grass-Cow-Milk Dose Factors....................................

11.4-51 Table 4-20 Adult Grass-Goat-Milk Dose Factors....................................

11.4-53 Table 4-21 Teen Grass-Goat-Milk Dose Factors....................................

11.4-55 Table 4-22 Child Grass-Goat-Milk Dose Factors....................................

11.4-57 Table 4-23 Infant Grass-Goat-Milk Dose Factors...................................

11.4-59 Table 4-24 Adult Grass-Cow-Meat Dose Factors...................................

11.4-61 Table 4-25 Teen Grass-Cow-Meat Dose Factors...................................

11.4-63 Table 4-26 Child Grass-Cow-Meat Dose Factors...................................

11.4-65 Table 4-27 Byron Station Characteristics...............................................

11.4-67 Table 4-28 Dose Factors for Noble Gases.............................................

11.4-68 Table 6-1 Radiological Environmental Monitoring Program................ 11.6-2 Table 6-2 Latitude/Longitude Positions of REMP samples................... 11.6-15 Page 5 of 7

CY-BY-170-301 Revision 8 ODCM TABLE OF CONTENTS LIST OF FIGURES PART I - RADIOLOGICAL EFFLUENTS NONE PART II - ODCM Figure 1-1 Figure 1-2 Figure 1-3 Figure 2-1 Figure 2-2 Figure 2-3 Figure 6-1 Figure 6-2 Figure 6-3 Figure 6-4 Radiation Exposure Pathways to Humans........................

11.1-9 Removed - See Figure 6-1............................................................

Restricted Area Boundary....................................................

11.1-20 Simplified HVAC & Gaseous Effluent Flow Diagram............ 11.2-15 Simplified Liquid Radwaste Processing Diagram................. 11.2-17 Liquid Release Flow Path.....................................................

11.2-18 Onsite Air Sampling Locations and Unrestricted Area B ounda ry..............................................................................

11.6-11 Offsite Air Sampling Locations.............................................

11.6-12 Inner Ring & Outer Ring Dosimeter Locations.....................

11.6-13 Ingestion & Waterborne Exposure Pathway Sample Locatio ns..............................................................................

11.6-14 I

Page 6 of 7

CY-BY-170-301 Revision 8 PAGE INTENTIONALLY LEFT BLANK Page 7 of 7

CY-BY-1 70-3011 Revision 8 RADIOLOGICAL EFFLUENTS FOR BYRON STATION UNITS 1 AND 2 REVISION 8 JUNE, 2012

CY-BY-170-301 Revision 8 1.0 DEFINITIONS 1.1 ACTIONS shall be that part of a Requirement that prescribes Required Actions to be taken under designated Conditions within specified Completion Times.

1.2 CHANNEL CALIBRATION shall be the adjustment, as necessary, of the channel so that it responds within the required range and accuracy to known inputs. The CHANNEL CALIBRATION shall encompass the entire channel, including the required sensor, alarm, interlock, display, and trip functions. Calibration of instrument channels with Resistance Temperature Detector (RTD) or thermocouple sensors may consist of an in place qualitative assessment of sensor behavior and normal calibration of the remaining adjustable devices in the channel. The CHANNEL CALIBRATION may be performed by means of any series of sequential, overlapping calibrations or total channel steps so that the entire channel is calibrated.

1.3 CHANNEL CHECK shall be the quantitative assessment, by observation, of channel behavior during operation. This determination shall include, where possible, comparison of the channel indication and status to other indications or status derived from independent instrument channels measuring the same parameter.

1.4 CHANNEL OPERATIONAL TEST (COT) shall be the injection of a simulated or actual signal into the channel as close to the sensor as practicable to verify the OPERABILITY of required alarm, interlock, display and trip functions. The COT shall include adjustments, as necessary, of the required alarm, interlock, and trip setpoints so that the setpoints are within the required range and accuracy.

1.5 DOSE EQUIVALENT 1-131 shall be that concentration of 1-131 (microcuries/gram) that alone would produce the same thyroid dose as the quantity and isotopic mixture of 1-131, 1-132, 1-133, 1-134, and 1-135 actually present. The dose conversion factors used for this calculation shall be those listed in Table III of TID-14844, AEC, 1962. "Calculation of Distance Factors for Power and Test Reactor Sites," or those listed in Table E-7 of Regulatory Guide 1.109, Rev. 1, NRC, 1977, or ICRP 30, Supplement to Part 1, pages 192-212, Table Titled, "Committed Dose Equivalent in Target Organs or Tissues per Intake of Unit Activity, or Federal Guidance Report 11, "Limiting Values of Radionuclide Intake and Air Concentration and Dose Conversion Factors for Inhalation, Submersion and Ingestion," 1989, (Table 2.1, Exposure-to-Dose Conversion Factors for Inhalation).

1.6 FREQUENCY - Table 1-a provides the definitions of various frequencies for which surveillances, sampling, etc., are performed unless defined otherwise. The 25% variance shall not be applied to Operability Action statements. The bases to Surveillance Requirement 3.0.2 provide clarifications to this requirement.

1.7 IMMEDIATELY - When "immediately" is used as a completion time the Required Action should be pursued without delay and in a controlled manner.

1.8 MEMBER(S) OF THE PUBLIC shall include all persons who are not occupationally associated with the plant. This category does not include employees of the licensee, its contractors or vendors and persons who enter the site to service equipment or to make deliveries. This category does include persons who use portions of the site for recreational, occupational, or other purposes not associated with the plant.

1.9 MODE shall correspond to any one inclusive combination of core reactivity condition, power level, average reactor coolant temperature, and reactor vessel head closure bolt tensioning specified in TRM Table T1.1-1 with fuel in the reactor vessel.

Page 1.1-1

CY-BY-170-301 Revision 8 1.10 OCCUPATIONAL DOSE means the dose received by an individual in the course of employment in which the individual's assigned duties involve exposure to radiation and/or to radioactive material from licensed and unlicensed sources of radiation, whether in the possession of the licensee or other person. Occupational dose does not include dose from background radiation, as a patient from medical practices, from voluntary participation in medical research programs, or as a member of the public.

1.11 A system, subsystem, train, component, or device shall be OPERABLE or have OPERABILITY when it is capable of performing its specified safety functions(s) and when all necessary attendant instrumentation, controls, normal or emergency electrical power, cooling and seal water, lubrication, and other auxiliary equipment that are required for the system, subsystem, train, component, or device to perform its specified safety function(s) are also capable of performing their related support function(s).

1.12 PROCESS CONTROL PROGRAM (PCP) shall contain the current formulas, sampling, analyses, tests, and determinations to be made to ensure that processing and packaging of solid radioactive wastes based on demonstrated processing of actual or simulated wet solid wastes will be accomplished in such a way as to assure compliance with 10 CFR Parts 20, 61, and 71, State regulations, burial ground requirements and other requirements governing the disposal of solid radioactive waste.

1.13 PURGEIPURGING shall be any controlled process of discharging air or gas from a confinement to maintain temperature, pressure, humidity, concentration or other operating condition, in such a manner that replacement air or gas is required to purify the confinement.

1.14 RATED THERMAL POWER shall be a total core heat transfer rate to the reactor coolant of 3586.6 MWT. (3645 MWT following NRC approval of License Amendment Request submitted under Exelon letter RS-1 1-099 and implementation of power uprate per Byron Unit 1 EC 378382 and Unit 2 EC 378383) 1.15 RADIOLOGICAL EFFLUENTS (RE) are in accordance with Byron Technical Requirements Manual (TRM) and the Code of Federal Regulations.

1.16 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM (REMP) are in accordance with Byron Technical Requirements Manual (TRM) and the Code of Federal Regulations.

1.17 SITE BOUNDARY shall be that line beyond which, the land is neither owned, nor leased, nor otherwise controlled by the licensee.

1.18 SOLIDIFICATION shall be the conversion of wet wastes into a form that meets shipping and burial ground requirements.

1.19 SOURCE CHECK shall be the qualitative assessment of channel response when the channel sensor is exposed to a source of increased radioactivity.

1.20 THERMAL POWER shall be the total reactor core heat transfer rate to the reactor coolant.

1.21 TLCO-TECHNICAL LIMITING CONDITION FOR OPERATION Limiting Condition for Operation as listed in the TRM.

1.22 TECHNICAL REQUIREMENTS MANUAL (TRM) Chapter 3.11 contains the Radiological Effluents (RE). Chapter 3.12 contains the Radiological Environmental Monitoring Program (REMP).

1.23 UNRESTRICTED AREA means an area, access to which is neither limited nor controlled by the licensee.

Page 1. 1-2

CY-BY-1 70-301 Revision 8 1.24 VENTILATION EXHAUST TREATMENT SYSTEM shall be any system designed and installed to reduce gaseous radioiodine or radioactive material in particulate form in effluents by passing ventilation or vent exhaust gases through charcoal adsorbers and/or HEPA filters for the purpose of removing iodines or particulates from the gaseous exhaust stream prior to the release to the environment. Such a system is not considered to have any effect on noble gas effluents.

Engineered Safety Features Atmospheric Cleanup Systems are not considered VENTILATION EXHAUST TREATMENT SYSTEM components.

1.25 VENTING shall be any controlled process of discharging air or gas from a confinement to maintain temperature, pressure, humidity, concentration or other operating condition, in such a manner that replacement air or gas is not provided or required during VENTING. Vent, used in system names, does not imply a VENTING process.

1.26 WASTE GAS HOLDUP SYSTEM shall be any system designed and installed to reduce radioactive gaseous effluents by collecting Reactor Coolant System off-gases from the Reactor Coolant System and providing for delay or holdup for the purpose of reducing the total radioactivity prior to release to the environment.

1.27 Definitions Peculiar to Estimating Dose to Members of the Public using the OFFSITE DOSE CALCULATION MANUAL (ODCM) Computer Program.

a.

ACTUAL - ACTUAL refers to using known release data to project the dose to members of the public for the previous time period. This data is stored in the database and used to demonstrate compliance with the reporting requirements of the ODCM.

b.

PROJECTED - PROJECTED refers to using known release data from the previous time period or estimated release data to forecast a future dose to members of the public. This data is not incorporated into the database.

Page 1. 1-3

CY-BY-170-301 I Revision 8 Table 1-a FREQUENCY NOTATIONS*

Notation Frequency S - Shiftly D - Daily W - Weekly B-Biweekly M - Monthly Q - Quarterly SA - Semiannually A - Annually R - Refuel Cycle S/U - Startup N.A.

P - Prior At least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> At least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> At least once per 7 days At least once every 14 days At least once per 31 days At least once per 92 days At least once per 184 days At least once per 366 days At least once per 18 months Prior to each reactor startup Not applicable Prior to each radioactive release

  • Each frequency requirement shall be performed within the specified time interval with the maximum allowable extension not to exceed 25% of the frequency interval. The 25% variance shall not be applied to Operability Action statements. The bases to TSR 3.0.b provide clarifications to this requirement. These frequency notations do not apply to the Radiological Environmental Monitoring Program as described in TRM 3.12.

Page 1. 1-4

CY-BY-1 70-301 Revision 8 Table 1-b COMPLIANCE MATRIX ODCMTehia Regulation Dose Component Limit On TRM Technical Equation Specification 10 CFR 50

1. Gamma air dose and beta air dose due to 4-4 3.11.g 5.5.4.h Appendix I airborne radioactivity in effluent plume.

4-5

a. Total body and skin dose due to airborne 4-6 N/A N/A radioactivity in effluent plume are 4-7 reported only if certain gamma and beta air dose crtera are exceeded.
2. Dose for all organs and all four age groups 4-8 3.11.h 5.5.4.i due to iodines and particulates in effluent plume. All pathways are considered.
3. Dose for all organs and all four age groups 3-3 3.1 1.d 5.5.4.d due to radioactivity in liquid effluents.

10 CFR 20

1. Total Dose, totaling all external dose 5-2 N/A 5.5.4.c components (direct, ground and plume shine) and internal dose (all pathways, both airborne and liquid-borne).

40 CFR 190

1. Total body dose due to direct dose, 5-1 3.1 1.k 5.5.4.j (now by ground and plume shine from all sources at a reference, station.

also part of 10 CFR 20)

2. Organ doses to an adult due to all 3-3 pathways.

4-8 Technical

1. "Instantaneous" total body, skin and organ 4-1 3.1 1.f 5.5.4.g Specifications dose rates to a child due to radioactivity in 4-2 airborne effluents. For the organ dose, only 4-3 inhalation is considered.
2. "Instantaneous" concentration limits for liquid effluents.

3-1 3.11.c 5.5.4.b Technical

1. Radioactive Effluent Release Report N/A N/A 5.6.3 Specifications I Page 1. 1-5

CY-BY-1 70-301 Revision 8 Table 1-b Page 2 of 2 COMPLIANCE MATRIX Regulation Component Limit ODCM TRM Technical Equation Specification 10CFR50 Appendix I

1. Implement Environmental Monitoring Program.

N/A 3.12.a N/A Section IV.B.2 10CFR50 Appendix I

1. Land Use Census N/A 3.12.b N/A Section IV.B.3 10CFR50 Appendix I
1. Interlaboratory Comparison Program N/A 3.12.c N/A Section IV.B.2 10CFR50 Appendix I Section IV.B.2
1. Annual Radiological Environmental Operating N/A N/A 5.6.2 and Technical Report Specifications I I

I I

Page 1. 1-6

CY-BY-170-301 Revision 8 NOTE:

2.0 through 3.10 Not Used 3.11 Radiological Effluents and Radiological Environmental Monitoring Program NOTE:

SEE TRM Chapter 3.11 for Radiological Effluents (RE) and TRM Chapter 3.12 for Radiological Environmental Monitoring Program (REMP).

Page 1.3-1

CY-BY-1 70-301 Revision 8 3.13 METEOROLOGICAL MONITORING PROGRAM 3.13.1 METEOROLOGICAL MONITORING Meteorological parameters are measured in the vicinity of each nuclear power station in order to provide data for calculating radiation doses due to airborne effluent radioactivity. Some nuclear power stations' Technical Specifications state applicable requirements (typically under the subheading, "Meteorological Instrumentation,"

in the instrumentation section). Regulatory guidance is given in Regulatory Guide 1.23 (Reference 5). Wind speed, wind direction and the temperature gradient are measured using instruments at two or more elevations on a meteorological tower at each Exelon Nuclear station. The elevations are chosen to provide meteorological data representative of the elevations of the airborne releases from the station. The Annual Radiological Environmental Operating Report includes a summary of meteorological data collected over the reporting year.

3.13.2 METEOROLOGICAL CONTRACTOR The meteorological contractor operates and maintains the meteorological tower instrumentation at each nuclear power station. The contractor collects and analyzes the data and issues periodic reports. The contractor prepares the meteorological data summary required for the Annual Radiological Environmental Operating Report (AREOR).

Page 1.3-2

CY-BY-1 70-301 Revision 8 4.0 BASES 4.1 RADIOACTIVE LIQUID EFFLUENT MONITORING INSTRUMENTATION (TRM 3.11.a)

The radioactive liquid effluent instrumentation is provided to monitor and control, as applicable, the releases of radioactive materials in liquid effluents during actual or potential releases of liquid effluents. The alarm/trip setpoints for these instruments shall be calculated and adjusted in accordance with the methodology and parameters in the ODCM to ensure that the alarm/trip will occur prior to exceeding 10 times the EFFLUENT CONCENTRATION values specified in Appendix B, Table 2, Column 2 to 10 CFR 20. The OPERABILITY and use of this instrumentation is consistent with the requirements of General Design Criteria 60, 63 and 64 of Appendix A to 10 CFR Part 50. The purpose of tank level indicating devices is to assure the detection and control of leaks that if not controlled could potentially result in the transport of radioactive materials to UNRESTRICTED AREAS.

4.2 RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION (TRM 3.1 1.b)

The radioactive gaseous effluent instrumentation is provided to monitor and control, as applicable, the releases of radioactive materials in gaseous effluents during actual or potential releases of gaseous effluents. The alarm/trip setpoints for these instruments shall be calculated and adjusted in accordance with the methodology and parameters in the ODCM to ensure that the alarm/trip will occur prior to exceeding the limits of 10 CFR Part 20. The OPERABILITY and use of this instrumentation is consistent with the requirements of General Design Criteria 60, 63 and 64 of Appendix A to 10 CFR Part 50.

4.3 CONCENTRATION LIMITS FOR EFFLUENTS (TRM 3.11.c)

This Control is provided to ensure that the concentration of radioactive materials released in liquid waste effluents to UNRESTRICTED AREAS will be less than 10 times the EFFLUENT CONCENTRATION values specified in Appendix B, Table 2, Column 2 to 10 CFR 20. The Control provides operational flexibility for releasing liquid effluents in concentrations to follow the Section II.A and II.C design objectives of Appendix I to 10 CFR Part 50. This limitation provides reasonable assurance that the levels of radioactive materials in bodies of water in UNRESTRICTED AREAS will result in exposures within (1) the Section II.A design objectives of Appendix 1, 10 CFR Part 50, to a MEMBER OF THE PUBLIC and (2) the restrictions authorized by 10 CFR Part 20.1301(e). The concentration limit for the dissolved or entrained noble gases is based upon the assumption that Xe-1 33 is the controlling radionuclide and its EFFLUENT CONCENTRATION in air (submersion) was converted to an equivalent concentration in water. This control does not affect the requirement to comply with the annual limitations of 10 CFR Part 20.1301 (a).

This Control applies to the release of radioactive materials in liquid effluents from all units at the site.

The required detection capabilities for radioactive materials in liquid waste samples are tabulated in terms of the lower limits of detection (LLDs). Detailed discussion of the LLD and other detection limits can be found in Currie, L.A., "Lower Limit of Detection: Definition and Elaboration of a Proposed Position for Radiological Effluent and Environmental Measurements," NUREG/CR-4007 (September 1984), and in the HASL Procedures Manual, HASL-300 (revised annually).

Page 1.4-1

CY-BY-170-301 Revision 8 4.4 DOSE FROM LIQUID EFFLUENTS (TRM 3.114.d This Control is provided to implement the requirements of Sections II.A, III.A and IV.A of Appendix I, 10 CFR Part 50. The Control statement implements the guides set forth in Section II.A of Appendix I. The Action statements provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I to assure that the releases of radioactive material in liquid effluents will be kept "as low as is reasonably achievable." Also, for fresh water sites with drinking water supplies that can be potentially affected by plant operations, there is reasonable assurance that the operation of the facility will not result in radionuclide concentrations in the finished drinking water that are in excess of the requirements of 40 CFR Part 141. The dose calculation methodology and parameters in the ODCM implement the requirements in Section IIl.A of Appendix I that conformance with the guides of Appendix I be shown by calculational procedures based on models and data, such that the actual exposure of a MEMBER OF THE PUBLIC through appropriate pathways is unlikely to be substantially underestimated.

The equations specified in the ODCM for calculating the doses due to the actual release rates of radioactive materials in liquid effluents are consistent with the methodology provided in Regulatory Guide 1.109, "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I," Revision 1, October 1977 and Regulatory Guide 1.113, "Estimating Aquatic Dispersion of Effluents from Accidental and Routine Reactor Releases for the Purpose of Implementing Appendix I," April 1977.

This Control applies to the release of liquid effluents from each reactor at the site. For units with shared radwaste treatment systems, the liquid effluents from the shared system are proportioned among the units sharing that system.

4.5 LIQUID RADWASTE TREATMENT SYSTEM (TRM 3.11.e)

The OPERABILITY of the Liquid Radwaste Treatment System ensures that this system will be available for use whenever liquid effluents require treatment prior to release to the environment. The requirement that the appropriate portions of this system be used, when specified, provides assurance that the releases of radioactive materials in liquid effluents will be kept "as low as is reasonably achievable". This Control implements the requirements of 10 CFR Part 50.36a, General Design Criterion 60 of Appendix A to 10 CFR Part 50 and the design objective given in Section II.D of Appendix I to 10 CFR part 50. The specified limits governing the use of appropriate portions of the liquid radwaste treatment system were specified as a suitable fraction of the dose design objectives set forth in Section II.A of Appendix I, 10 CFR Part 50, for liquid effluents.

This Control applies to the release of liquid effluents from each reactor at the site. For units with shared radwaste treatment systems, the liquid effluents from the shared system are proportioned among the units sharing that system.

Page 1.4-2

CY-BY-1 70-301 Revision 8 4.6 DOSE RATE FOR GASEOUS EFFLUENT (TRM 3.11.f)

This Control provides reasonable assurance that radioactive material discharged in gaseous effluents will not result in the exposure of a MEMBER OF THE PUBLIC in an UNRESTRICTED AREA, either at or beyond the SITE BOUNDARY in excess of the design objectives of Appendix I to 10 CFR Part 50. This Control is provided to ensure that gaseous effluents from all units on the site will be appropriately controlled. It provides operational flexibility for releasing gaseous effluents to satisfy the Section II.A and II.C design objectives of Appendix I to 10 CFR Part 50. For MEMBERS OF THE PUBLIC who may at times be within the SITE BOUNDARY, the occupancy of that MEMBER OF THE PUBLIC will usually be sufficiently low to compensate for the reduced atmospheric dispersion of gaseous effluents relative to that for the SITE BOUNDARY. Examples of calculations for such MEMBERS OF THE PUBLIC, with the appropriate occupancy factors, shall be given in the ODCM. The specified release rate limits restrict, at all times, the corresponding dose rates above background to a MEMBER OF THE PUBLIC at or beyond the SITE BOUNDARY to less than or equal to 500 mrem/year to the total body or to less than or equal to 3000 mrem/year to the skin. These release rate limits also restrict, at all times, the corresponding thyroid dose rate above background to a child via the inhalation pathway to less than or equal to 1500 mrem/year. This Control does not affect the requirement to comply with the annual limitations of 10 CFR 20.1301(a).

This Control applies to the release of gaseous effluents from all units at the site.

The required detection capabilities for radioactive materials in gaseous waste samples are tabulated in terms of the lower limits of detection (LLDs). Detailed discussion of the LLD and other detection limits can be found in Currie, L.A., "Lower Limit of Detection: Definition and Elaboration of a Proposed Position for Radiological Effluent and Environmental Measurements," NUREG/CR-4007 (September 1984), and in the HASL Procedures Manual, HASL-300 (revised annually).

4.7 DOSE - NOBLE GASES (TRM 3.11.q)

This Control is provided to implement the requirements of Sections lI.B, III.A and IV.A of Appendix I, 10 CFR Part 50. The Control statements implement the guides set forth in Section II.B of Appendix I. The Action statements provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I to assure that the releases of radioactive material in gaseous effluents will be kept "as low as is reasonably achievable." The Surveillance Requirements implement the requirements in Section III.A of Appendix I that conformance with the guides of Appendix I be shown by calculational procedures based on models and data such that the actual exposure of a MEMBER OF THE PUBLIC through appropriate pathways is unlikely to be substantially underestimated.

The dose calculation methodology and parameters established in the ODCM for calculating the doses due to the actual release rates of radioactive noble gases in gaseous effluents are consistent with the methodology provided in Regulatory Guide 1.109, "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I," Revision 1, October 1977 and Regulatory Guide 1.111, "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water Cooled Reactors,"

Revision 1, July 1977. The ODCM equations provided for determining the air doses at and beyond the SITE BOUNDARY are based upon the historical average atmospheric conditions.

This Control applies to the release of gaseous effluents from each reactor at the site. For units with shared radwaste treatment systems, the gaseous effluents from the shared system are proportioned among the units sharing that system.

Page 1.4-3

CY-BY-1 70-301 Revision 8 4.8 DOSE-IODINE-131, TRITIUM, AND RADIOACTIVE MATERIAL IN PARTICULATE FORM (TRM 3.11.h)

This Control is provided to implement the requirements of Sections II.C, III.A and IV.A of Appendix 1, 10 CFR Part 50. The Controls are the guides set forth in Section II.C of Appendix I. The Action statements provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I to assure that the releases of radioactive materials in gaseous effluents will be kept "as low as is reasonably achievable." The ODCM calculational methods specified in the Surveillance Requirements implement the requirements in Section III.A of Appendix I that conformance with the guides of Appendix I be shown by calculational procedures based on models and data, such that the actual exposure of a MEMBER OF THE PUBLIC through appropriate pathways is unlikely to be substantially underestimated.

The ODCM calculational methodology and parameters for calculating the doses due to the actual release rates of the subject materials are consistent with the methodology provided in Regulatory Guide 1.109, "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I," Revision 1, October 1977 and Regulatory Guide 1.111, 'Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water-Cooled Reactors," Revision 1, July 1977. These equations also provide for determining the actual doses based upon the historical average atmospheric conditions. The release rate controls for Iodine-131, Tritium, and radionuclides in particulate form with half-lives greater than 8 days are dependent upon the existing radionuclide pathways to man, in the areas at and beyond the SITE BOUNDARY. The pathways that were examined in the development of these calculations were: 1) individual inhalation of airborne radionuclides, 2) deposition of radionuclides onto green leafy vegetation with subsequent consumption by man, 3) deposition onto grassy areas where milk animals and meat producing animals graze with consumption of the milk and meat by man, and 4) deposition on the ground with subsequent exposure of man.

This Control applies to the release of gaseous effluents from each reactor at the site. For units with shared radwaste treatment systems, the gaseous effluents from the shared systems are proportioned among the units sharing that system.

4.9 GASEOUS RADWASTE TREATMENT SYSTEM (TRM 3.11.i)

The OPERABILITY of the Gaseous Radwaste Treatment System ensures that the system will be available for use whenever gaseous effluents require treatment prior to release of the environment. The requirement that the appropriate portions of these systems be used, when specified, provides reasonable assurance that the release of radioactive materials in gaseous effluents will be kept "as low as is reasonably achievable." This Control implements the requirements of 10 CFR Part 50.36a, General Design Criterion 60 of Appendix A to 10 CFR Part 50, and the design objectives given in Section II.D of Appendix I to 10 CFR Part 50.

The specified limits governing the use of appropriate portions of the systems were specified as a suitable fraction of the dose design objectives set forth in Sections Il.B and II.C of Appendix I, 10 CFR Part 50, for gaseous effluents.

This Control applies to the release of gaseous effluents from each reactor at the site. For units with shared radwaste treatment systems, the gaseous effluents from the shared systems are proportioned among the units sharing that system.

Page 1.4-4

CY-BY-1 70-301 Revision 8 4.10 TOTAL DOSE (TRM 3.11.k)

This Control is provided to meet the dose limitations of 40 CFR Part 190 that have been incorporated into 10 CFR Part 20.1301 (d). The Control requires the preparation and submittal of a Special Report whenever the calculated doses due to releases of radioactivity and to radiation from uranium fuel cycle sources exceed 25 mrems to the total body or any organ, except the thyroid, which shall be limited to less than or equal to 75 mrems.

For sites containing up to 4 reactors, it is highly unlikely that the resultant dose to a MEMBER OF THE PUBLIC will exceed the dose limits of 40 CFR Part 190 if the individual reactors remain within twice the dose design objectives of Appendix I, and if direct radiation doses from the reactor units and outside storage tanks, etc., are kept small. The Special Report will describe a course of action that should result in the limitation of the annual dose to a MEMBER OF THE PUBLIC to within the 40 CFR Part 190 limits.

For the purposes of the Special Report, it may be assumed that the dose commitment to the MEMBER OF THE PUBLIC from other uranium fuel cycle sources is negligible, with the exception that dose contributions from other nuclear fuel cycle facilities at the same site or within a radius of 8 km must be considered. If the dose to any MEMBER OF THE PUBLIC is estimated to exceed the requirements of 40 CFR Part 190, submittal of the Special Report within 30 days with a request for a variance (provided the release conditions resulting in violation of 40 CFR Part 190 have not already been corrected), in accordance with the provisions of 40 CFR Part 190.11 and 10 CFR Part 20.2203(a)(4), is considered to be a timely request and fulfills the requirements of 40 CFR Part 190 until NRC staff action is completed.

Demonstration of compliance with the limits of 40 CFR Part 190 or with the design objectives of Appendix I to 10 CFR Part 50 will be considered to demonstrate compliance with the 0.1 rem limit of 10 CFR Part 20.1301.

4.11 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM (TRM 3.12)

The Radiological Environmental Monitoring Program required by this Control provides representative measurements of radiation and of radioactive materials in those exposure pathways and for those radionuclides that lead to the highest potential radiation exposures of MEMBERS OF THE PUBLIC resulting from the station operation.

This monitoring program implementsSection IV.B.2 of Appendix I to 10 CFR Part 50 and thereby supplements the Radiological Effluent Monitoring Program by verifying that the measurable concentrations of radioactive materials and levels of radiation are not higher than expected on the basis of the effluent measurements and the modeling of the environmental exposure pathways. Isotopes identified in REMP are compared to those identified in the applicable Annual Effluent Report. Program changes may be initiated based on these operational experiences.

The required detection capabilities for environmental sample analyses are tabulated in terms of the lower limits of detection (LLDs). The LLDs required by Table T3.12.a-3 are considered optimum for routine environmental measurements in industrial laboratories. It should be recognized that the LLD is defined as an _a qr (before the fact) limit representing the capability of a measurement system and not as an a posteriori (after the fact) limit for a particular measurement.

Detailed discussion of the LLD and other detection limits can be found in Currie, L.A., "Lower Limit of Detection: Definition and Elaboration of a Proposed Position for Radiological Effluent and Environmental Measurements," NUREG/CR-4007 (September 1984), and in the HASL Procedures Manual, HASL-300 (revised annually).

Page 1.4-5

CY-BY-1 70-301 Revision 8 4.12 LAND USE CENSUS (TRM 3.12.b)

This Control is provided to ensure that changes in the use of areas at and beyond the SITE BOUNDARY are identified and that modifications to the Radiological Environmental Monitoring Program are made if required by the results of this census. The best information from the door-to-door survey, from aerial survey or from consulting with local agricultural authorities shall be used. This census satisfies the requirements of Section IV.B.3 of Appendix I to 10 CFR Part 50. Restricting the census to gardens of greater than 50 m2 provides assurance that significant exposure pathways via leafy vegetables will be identified and monitored since a garden of this size is the minimum required to produce the quantity (26 kg/year) of leafy vegetables assumed in Regulatory Guide 1.109 for consumption by a child. To determine this minimum garden size, the following assumptions were made: 1) 20% of the garden was used for growing broad leaf vegetation (i.e., similar to lettuce and cabbage), and 2) a vegetation yield of 2 kg/m2.

4.13 INTERLABORATORY COMPARISON PROGRAM (TRM 3.12.c)

The requirement for participation in an approved Interlaboratory Comparison Program is provided to ensure that independent checks on the precision and accuracy of the measurements of radioactive material in environmental sample matrices are performed as part of the quality assurance program for environmental monitoring in order to demonstrate that the results are reasonably valid for the purposes of Section IV.B.2 of Appendix I to 10 CFR Part 50.

Page 1.4-6

CY-BY-1 70-301 Revision 8 5.0 ADMINISTRATIVE REQUIREMENTS 5.1 Annual Radiological Environmental Operating Report*

Routine Annual Radiological Environmental Operating Report covering the operation of the Unit(s) during the previous calendar year shall be submitted prior to May 15 of each year.

The Annual Radiological Environmental Operating Report shall include summaries, interpretations, and an analysis of trends of the results of the radiological environmental surveillance activities for the report period, including a comparison with operational controls as appropriate, and with previous environmental surveillance reports, and an assessment of the observed impacts of the plant operation on the environment.

The Annual Radiological Environmental Operating Report shall include the results of all radiological environmental samples and of all environmental radiation measurements taken during the period pursuant to the locations specified in the tables and figures in Part II Section 6 of the ODCM, as well as summarized and tabulated results of these analyses and measurements in the format of the table in the Radiological Assessment Branch Technical Position, Revision 1, November 1979. In the event that some individual results are not available for inclusion with the report, the report shall be submitted noting and explaining the reasons for the missing results. The missing data shall be submitted as soon as possible in a supplementary report.

The reports shall also include the following: a summary description of the Radiological Environmental Monitoring Program; legible maps covering all sampling locations keyed to a table giving distances and directions from the midpoint between the two units; reasons for not conducting the Radiological Environmental Monitoring Program as required by TLCO 3.12.a, a Table of Missed Samples and a Table of Sample Anomalies for all deviations from the sampling schedule of TRM Table T3.12.a-1; discussion of environmental sample measurements that exceed the reporting levels of TRM Table T3.12.a-2 but are not the result of plant effluents, discussion of all analyses in which the LLD required by TRM Table T3.12.a-3 was not achievable; result of the Land Use Census required by TRM TLCO 3.12.b; and the results of the licensee participation in an Interlaboratory Comparison Program and the corrective actions being taken if the specified program is not being performed as required by TRM TLCO 3.12.c.

The Annual Radiological Environmental Operating Report shall also include an annual summary of hourly meteorological data collected over the applicable year. This annual summary may be either in the form of an hour-by-hour listing on magnetic tape of wind speed, wind direction, atmospheric stability, and precipitation (if measured), or in the form of joint frequency distributions of wind speed, wind direction, and atmospheric stability. In lieu of submission with the Annual Radiological Environmental Operating Report, the licensee has the option of retaining this summary of required meteorological data on site in a file that shall be provided to the NRC upon request.

The Annual Radiological Environmental Operating Report shall also include an assessment of the radiation doses due to the radioactive liquid and gaseous effluents released from the Unit or Station during the previous calendar year. This report shall also include an assessment of the radiation doses to the most likely exposed MEMBER OF THE PUBLIC from reactor releases and other near-by uranium fuel cycle sources including doses from primary effluent pathways and direct radiation, for the previous calendar year. The assessment of radiation doses shall be performed in accordance with the methodology and parameters in the ODCM, and in compliance with 10CFR20 and 40 CFR Part 190, "Environmental Radiation Protection Standards for Nuclear Power Operation."

  • A single submittal may be made for a multiple unit station.

Page 1.5-1

CY-BY-1 70-301 Revision 8 5.2 Annual Radioactive Effluent Release Report-Routine Annual Radioactive Effluent Release Reports covering the operation of the unit during the previous calendar year of operation shall be submitted prior to May 1 of the following year.

The Annual Radioactive Effluent Release Reports shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the unit as outlined in Regulatory Guide 1.21, "Measuring Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants," Revision 1, June 1974, with data summarized on a quarterly basis following the format of Appendix B thereof.

For solid wastes, the format for Table 3 in Appendix B of the report shall be supplemented with three additional categories: class of solid wastes (as defined by 10 CFR Part 61), type of container (e.g.,

LSA, Type A, Type B, Large Quantity), and SOLIDIFICATION agent or absorbent (e.g., cement, urea formaldehyde).

The Annual Radioactive Effluent Release Reports shall include a list and description of unplanned releases from the site to UNRESTRICTED AREAS of radioactive materials in gaseous and liquid effluents made during the reporting period.

The Annual Radioactive Effluent Release Reports shall include any changes made during the reporting period to the PCP as well as any major changes to Liquid, Gaseous or Solid Radwaste Treatment Systems, pursuant to Part I Section 5.3.

The Annual Radioactive Effluent Release Reports shall also include the following: an explanation as to why the inoperability of liquid or gaseous effluent monitoring instrumentation was not corrected within the time specified in TRM TLCO 3.11.a or TLCO 3.11.b, respectively; and description of the events leading to liquid holdup tanks or gas storage tanks exceeding the limits of TS 5.5.12.

    • A single submittal may be made for a multiple unit station. The submittal should combine those sections that are common to all units at the station; however, for units with separate radwaste systems, the submittal shall specify the releases of radioactive material from each unit.

Page 1.5-2

CY-BY-1 70-301 Revision 8 5.3 ODCM 5.3.1 The ODCM shall be submitted to the Commission following proper approval through station processes.

5.3.2 Licensee-initiated changes to the ODCM:

a.

Shall be documented and records of reviews performed shall be retained as required by UFSAR Chapter 17. This documentation shall contain:

1.

Sufficient information to support the change together with the appropriate analyses or evaluations justifying the changes(s); and

2.

A determination that the change will maintain the level of radioactive effluent control required by 10 CFR Part 20, 40 CFR Part 190, 10 CFR 50.36a, and Appendix I to 10 CFR Part 50 and not adversely impact the accuracy or reliability of effluent, dose, or setpoint calculations.

b.

Shall become effective after review and acceptance by the Independent Technical Review and PORC and the approval of the Plant Manager on the date specified by the Independent Technical Review and PORC.

c.

Shall be submitted to the Commission in the form of the complete, legible copy of the entire ODCM, or updated pages if the Commission retains a controlled copy. If an entire copy of the ODCM is submitted, it shall be submitted as a part of or concurrent with the Annual Radioactive Effluent Release Report for the period of the report in which any change to the ODCM was made effective. Each change shall be identified by markings in the margin of the affected pages, clearly indicating the area of the page that was changed and shall indicate the date (eg. month/year) the change was implemented.

Page 1.5-3

CY-BY-170-301 Revision 8 5.4 Major Changes to Liquid and Gaseous Radwaste Treatment Systems***

Licensee-initiated major changes to the Radwaste Treatment Systems (liquid and gaseous):

a.

Shall be reported to the Commission in the Annual Radioactive Effluent Release Report for the period in which the evaluation was reviewed by the Independent Technical Review and PORC.

The discussion of each change shall contain:

1)

A summary of the evaluation that led to the determination that the change could be made in accordance with 10 CFR 50.59;

2)

Sufficient detailed information to totally support the reason for the change without benefit of additional and supplemental information;

3)

A detailed description of the equipment, components, and processes involved and the interfaces with other plant systems.

4)

An evaluation of the change which shows the predicted releases of radioactive materials in liquid and gaseous effluents that differ from those previously predicted in the License application and amendments thereto;

5)

An evaluation of the change, which shows the expected maximum exposures to a MEMBER OF THE PUBLIC in the UNRESTRICTED AREA and to the general population that differ from those previously estimated in the License application and amendments thereto;

6)

A comparison of the predicted releases of radioactive materials, in liquid and gaseous effluents, to the actual releases for the period prior to when the changes are to be made;

7)

An estimate of the exposure to plant operating personnel as a result of the change; and

8)

Documentation of the fact that the change was reviewed and found acceptable by the Independent Technical Review and PORC.

b.

Shall become effective upon review and acceptance by the Independent Technical Review and PORC.

  • '*Licensees may choose to submit the information called for in this standard as part of the annual FSAR update.

Page 1.5-4

CY-BY-1 70-301 Revision 8 PAGE INTENTIONALLY LEFT BLANK Page 1.5-5

CY-BY-1 70-301 Revision 8

1.0 INTRODUCTION

- ODCM GENERAL INFORMATION The Offsite Dose Calculation Manual (ODCM) presents a discussion of the following:

The basic concepts applied in calculating offsite doses from plant effluents.

The regulations and requirements for the ODCM and related programs.

The methodology and parameters for the offsite dose calculations to assess impact on the environment and compliance with regulations.

The methodology detailed in this manual is intended for the calculation of radiation doses during routine (i.e., non-accident) conditions. The calculations are normally performed using a computer program. Manual calculations may be performed in lieu of the computer program.

The dose effects of airborne radioactivity releases predominately depend on meteorological conditions (wind speed, wind direction, and atmospheric stability). For airborne effluents, the dose calculations prescribed in this manual are based on historical average atmospheric conditions. This methodology is appropriate for estimating annual average dose effects and is stipulated in the Bases Section of the Radiological Effluents (RE).

1.1 Structure of the ODCM Part I of the ODCM is considered to be the Radiological Effluents (RE), and contains the former Radiological Effluent Technical Specifications that have been removed from the Technical Specifications. Part I is organized as follows:

  • Definitions
  • Radiological Effluents and Radiological Environmental Monitoring Program
  • Meteorological Monitoring Program
  • Bases
  • Administrative Requirements Page 11.1-1

CY-BY-170-301 Revision 8 Part II of the ODCM is considered to be the Offsite Dose Calculation Manual (ODCM), and contains methods, equations, assumptions, and parameters for calculation of radiation doses from plant effluents. Part II is organized as follows:

Introduction Instrumentation and Systems

  • Liquid Effluents
  • Gaseous Effluents
  • Total Dose Radiological Environmental Monitoring Program 1.2 Regulations This section serves to illustrate the regulations and requirements that define and are applicable to the ODCM. Any information provided in the ODCM concerning specific regulations are not a substitute for the regulations as found in the Code of Federal Regulations (CFR) or Technical Specifications.

1.2.1 Code of Federal Regulations Various sections of the Code of Federal Regulations (CFR) require nuclear power stations to be designed and operated in a manner that limits the radiation exposure to members of the public. These sections specify limits on offsite radiation doses and on effluent radioactivity concentrations and they also require releases of radioactivity to be "As Low As Reasonably Achievable". These requirements are contained in 10CFR20, 10CFR50 and 40CFR190. In addition, 40CFR141 imposes limits on the concentration of radioactivity in drinking water provided by the operators of public water systems.

  • 10CFR20, Standards for Protection Against Radiation This revision of the ODCM addresses the requirements of 10CFR20. The 10CFR20 dose limits are summarized in Table 1 - 1.

0 Design Criteria (Appendix A of 1 OCFR50)

Section 50.36 of 10CFR50 requires that an application for an operating license include proposed Technical Specifications. Final Technical Specifications for each station are developed through negotiation between the applicant and the NRC. The Technical Specifications are then issued as a part of the operating license, and the licensee is required to operate the facility in accordance with them.

Section 50.34 of 10CFR50 states that an application for a license must state the principal design criteria of the facility. Minimum requirements are contained in Appendix A of 10CFR50.

ALARA Provisions (Appendix I of 10CFR50)

Page 11.1-2

CY-BY-170-301 Revision 8 Sections 50.34a and 50.36a of 1 0CFR50 require that the nuclear plant design and the station RECS have provisions to keep levels of radioactive materials in effluents to unrestricted areas "As Low As Reasonably Achievable" (ALARA).

Although 10CFR50 does not impose specific limits on releases, Appendix I of 10CFR50 does provide numerical design objectives and suggested limiting conditions for operation. According to Section I of Appendix I of 10CFR50, design objectives and limiting conditions for operation, conforming to the guidelines of Appendix I "shall be deemed a conclusive showing of compliance with the "As Low As Reasonably Achievable" requirements of 10CFR50.34a and 50.36a."

An applicant must use calculations to demonstrate conformance with the design objective dose limits of Appendix I. The calculations are to be based on models and data such that the actual radiation exposure of an individual is "unlikely to be substantially underestimated" (see 1 OCFR50 Appendix I,Section III.A.1).

The guidelines in Appendix I call for an investigation, corrective action and a report to the NRC whenever the calculated dose due to the radioactivity released in a calendar quarter exceeds one-half of an annual design objective.

The guidelines also require a surveillance program to monitor releases, monitor the environment and identify changes in land use.

  • 40CFR190, Environmental Radiation Protection Standards for Nuclear Power Operations Under an agreement between the NRC and the EPA, the NRC stipulated to its licensees in Generic Letter 79-041 that "Compliance with Radiological Effluent Technical Specifications (RETS), NUREG-0472 (Rev.2) for PWR's, implements the LWR provisions to meet 40CFR190". (See References 49 and 103.)

The regulations of 40CFR1 90 limit radiation doses received by members of the public as a result of operations that are part of the uranium fuel cycle.

Operations must be conducted in such a manner as to provide reasonable assurance that the annual dose equivalent to any member of the public due to radiation and to planned discharges of radioactive materials does not exceed the following limits:

o 25 mrem to the total body o 75 mrem to the thyroid o 25 mrem to any other organ An important difference between the design objectives of 1 OCFR50 and the limits of 40CFR190 is that 10CFR50 addresses only doses due to radioactive effluents. 40CFR190 limits doses due to effluents and to radiation sources maintained on site. See Section 1.2.4 for further discussion of the differences between the requirements of 10CFR50 Appendix I and 40CFR190.

Page 11.1-3

CY-BY-170-301 Revision 8 40CFR141, National Primary Drinking Water Regulations The following radioactivity limits for community water systems were established in the July, 1976 Edition of 40CFR141:

o Combined Ra-226 and Ra-228: < 5 pCi/L.

o Gross alpha (particle activity including Ra-226 but excluding radon and uranium): < 15 pCi/L.

o The average annual concentration of beta particle and photon radioactivity from man-made radionuclides in drinking water shall not produce an annual dose equivalent to the total body or any internal organ greater than 4 mrem/yr.

The regulations specify procedures for determining the values of annual average radionuclide concentration that produce an annual dose equivalent of 4 mrem. Radiochemical analysis methods are also specified. The responsibility for monitoring radioactivity in a community water system falls on the supplier of the water. The Byron Station has requirements related to 40CFR141 in the RECS.

10CFR72, Licensing Requirements for the Independent Storage of Spent Nuclear Fuel, High-Level Radioactive Waste, and Reactor-Related Greater Than Class C Waste 10CFR72.104 states that annual dose to any real individual located beyond the controlled area must not exceed the following:

o 25 mrem to the total body o 75 mrem to the thyroid o 25 mrem to any other critical organ as a result of planned discharges of radioactive material to the environment, direct radiation from ISFSI operation, and other radiation from uranium fuel cycle operation (40CFR1 90). These requirements are consistent with the requirements of 40CFR 190.

Page 11.1-4

CY-BY-170-301 Revision 8 1.2.2 Radiological Effluent Technical Standards The Radiological Effluent Technical Standards (RETS) were formerly a subset of the Technical Specifications. They implement provisions of the Code of Federal Regulations aimed at limiting offsite radiation dose. The NRC published Standard RETS for PWRs (Reference 2) as guidance to assist in the development of technical specifications. These documents have undergone frequent minor revisions to reflect changes in plant design and evolving regulatory concerns. The RETS have been removed from the Technical Specifications and placed in the TRM as the Radiological Effluents (RE) (see Reference 90). The RE are similar but not identical to the guidance of the Standard Radiological Effluent Technical Specifications.

1.2.3 Offsite Dose Calculation Manual The NRC in Generic Letter 89-01 defines the ODCM as follows (not verbatim) (see Reference 90):

The Offsite Dose Calculation Manual (ODCM) shall contain the methodology and parameters used in the calculation of offsite doses resulting from radioactive gaseous and liquid effluents, in the calculation of gaseous and liquid effluent monitoring Alarm/Trip Setpoints, and in the conduct of the Radiological Environmental Monitoring Program. The ODCM shall also contain (1) the Radioactive Effluent Controls and Radiological Environmental Monitoring Programs and (2) descriptions of the Information that should be included in the Annual Radiological Environmental Operating and Annual Radioactive Effluent Release Reports.

Additional requirements for the content of the ODCM are contained throughout the text of the RECS.

1.2.4 Overlapping Requirements In 10CFR20, 10CFR50 and 40CFR190, there are overlapping requirements regarding offsite radiation dose and dose commitment to the total body. In 10CFR20.1301, the total effective dose equivalent (TEDE) to a member of the public is limited to 100 mrem per calendar year. In addition, Appendix I to 1 OCFR50 establishes design objectives on annual total body dose or dose commitment of 3 mrem per reactor for liquid effluents and 5 mrem per reactor for gaseous effluents (see 10CFR50 Appendix I, Sections II.A and II.B.2(a)). Finally, 40CFR190 limits annual total body dose or dose commitment to a member of the public to 25 mrem due to all uranium fuel cycle operations.

Page 11.1-5

CY-BY-1 70-301 Revision 8 While these dose limits/design objectives appear to overlap, they are different and each is addressed separately by the RE. Calculations are made and reports are generated to demonstrate compliance to all regulations. Refer to Table 1 - 1 and Table 1 - 2 for additional information regarding instantaneous effluent limits, design objectives and regulatory compliance.

1.2.5 Dose Receiver Methodology Table 1 - 2 lists the location of the dose recipient and occupancy factors, if applicable. Dose is assessed at the location in the unrestricted area where the combination of existing pathways and receptor age groups indicates the maximum potential exposures. The dose calculation methodology is consistent with the methodology of Regulatory Guide 1.109 (Reference 6) and NUREG 0133 (Reference 14). Dose is therefore calculated to a maximum individual. The maximum individual is characterized as "maximum" with regard to food consumption, occupancy and other usage of the area in the vicinity of the plant site. Such a "maximum individual" represents reasonable deviation from the average for the population in general. In all physiological and metabolic respects, the maximum individual is assumed to have those characteristics that represent averages for their corresponding age group. Thus, the dose calculated is very conservative compared to the "average" (or typical) dose recipient who does not go out of the way to maximize radioactivity uptakes and exposure.

Page 11.1-6

CY-BY-170-301 Revision 8 Table 1 - 1 Regulatory Dose Limit Matrix TRM REGULATION DOSE TYPE DOSE LIMIT(s)

Section Airborne Releases:

(quarterly)

(annual) 1 0CFR50 App. I1 Gamma Dose to Air due to Noble Gas 5 mrad 10 mrad 3.11.g Radionuclides (per reactor unit)

Beta Dose to Air Due to Noble Gas 10 mrad 20 mrad 3.1 i.g Radionuclides (per reactor unit)

Organ Dose Due to Specified Non-Noble 7.5 mrem 15 mrem 3.11.h Gas Radionuclides (per reactor unit)

Total Body and Skin Total Body 2.5 mrem 5 mrem N/A Dose (if air dose is exceeded)

Skin 7.5 mrem 15 mrem N/A Technical Specifications Total Body Dose Rate Due to Noble Gas 500 mrern/yr 3.11.f Radionuclides (instantaneous limit, per site)

Skin Dose Rate Due to Noble Gas 3,000 mrem/yr 3.11.f Radionuclides (instantaneous limit, per site)

Organ Dose Rate Due to Specified Non-1,500 mrem/yr 3.11.f Noble Gas Radionuclides (instantaneous limit, per site)

Liquid Releases:

(quarterly)

(annual) 10CFR50 App. I' Whole (Total) Body Dose 1.5 mrem 3 mrem 3.11.d (per reactor unit)

Organ Dose (per reactor unit) 5 mrem 10 mrem 3.11.d Technical Specifications The concentration of radioactivity in liquid Ten times the values effluents released to unrestricted areas listed in 10CFR20 3.11.c Appendix B; Table 2, Column 2, and note 5 below for Noble Gases Total Doses 1:

ODCM Section II 10 CFR 20.1301 (a)(1)

Total Effective Dose Equivalent 4 100 mrem/yr 5.5 10CFR20.1301 (d)

Total Body Dose 25 mrem/yr 5.5 And 40CFR190 Thyroid Dose 75 mrem/yr 5.5 Other Organ Dose 25 mrem/yr 5.5 Other Limits 2:

40CFR141 Total Body Dose Due to Drinking Water 4 mrem/yr 3.4 From Public Water Systems Organ Dose Due to Drinking Water From 4 mrem/yr 3.4 Public Water Systems 1 These doses are calculated considering all sources of radiation and radioactivity in effluents.

2 These limits are not directly applicable to nuclear power stations. They are applicable to the owners or operators of public water systems. However, the Byron RECS requires assessment of compliance with these limits.

3 Note that 10CFR50 provides design objectives, not limits.

4 Compliance with 10CFR20.1301(a)(1) is demonstrated by compliance with 40CFR190. Note that it may be necessary to address dose from on-site activity by members of the public as well.

5 Kr-85m, Kr-85, Kr-87, Kr-88, Ar-41, Xe-131m, Xe-133m, Xe-133, Xe-135m and Xe-135 allowable concentration is 2E-4 pCi/ml computed from Equation 17 of ICRP Publication 2 adjusted for infinite cloud submersion in water, and R = 0.01 rem/wk, Pw = 1.0 g/cm3, and Pw/Pt = 1.0.

Page 11.1-7

CY-BY-170-301 Revision 8 Table 1 - 2 Dose Assessment Receivers Location; Occupancy if Dose Component or Pathway Different than 100%

"Instantaneous" dose rates from Unrestricted area boundary location that airborne radioactivity results in the maximum dose rate "Instantaneous" concentration limits in Point where liquid effluents enter the liquid effluents unrestricted area Annual average concentration limits for Point where liquid effluents enter the liquid effluents unrestricted area Direct dose from contained sources Receiver spends part of this time in the controlled area and the remainder at his residence or fishing nearby; occupancy factor is considered and is site-specific.

Direct dose from airborne plume Receiver is at the unrestricted area boundary location that results in the maximum dose.

Dose due to radioiodines, tritium and Receiver is at the location in the particulates with half-lives greater than unrestricted area where the combination of 8 days for inhalation, ingestion of existing pathways and receptor age groups vegetation, milk and meat, and ground indicates the highest potential exposures.

plane exposure pathways.

Ingestion dose from drinking water The drinking water pathway is considered as an additive dose component in this assessment only if the public water supply serves the community immediately adjacent to the plant.

Ingestion dose from eating fish The receiver eats fish from the receiving body of water Total Organ Doses Summation of ingestion/inhalation doses Total Dose Summation of above data (Note it may also be necessary to address dose from on-site activity by members of the public.)

Figure 1 - 1 illustrates some of the potential radiation exposure pathways to humans due to routine operation of a nuclear power station.

Page 11.1-8

CY-BY-170-301 Revision 8 Figure 1 - 1 Radiation Exposure Pathways to Humans Page 11.1-9

CY-BY-1 70-301 Revision 8 1.3 Offsite Dose Calculation Parameters This section contains offsite dose calculation parameter factors, or values not specific only to one of the gas, liquid, or total dose chapters. Additional parameters are provided in the Sections 2, 4 and 5 of the ODCM.

10CFR50 Dose Commitment Factors With the exception of H-3, the dose commitment factors for 1 OCFR50 related calculations are exactly those provided in Regulatory Guide 1.109 (Reference 6).

The following table lists the parameters and the corresponding data tables in the RG 1.109:

PATHWAY ADULT TEENAGER CHILD INFANT Inhalation RG 1.109:

RG 1.109:

RG 1.109:

RG 1.109:

Table E-7 Table E-8 Table E-9 Table E-10 Ingestion RG 1.109:

RG 1.109:

RG 1.109:

RG 1.109:

Table E-11 Table E-12 Table E-13 Table E-14 These tables are contained in Regulatory Guide 1.109 (Reference 6). Each table (E-7 through E-14) provides dose factors for seven organs for each of 73 radionuclides, and Table E-5 lists Miscellaneous Dose Assessment Factors -

Consumption Parameters. For radionuclides not found in these tables, dose factors will be derived from ICRP 2 (Reference 50) or NUREG-0172 (Reference 51). The values for H-3 are taken from NUREG-4013 (Reference 107).

1.4 REFERENCES

The references listed below were transferred from the previous ODCM revision that was common to all former Commonwealth Edison nuclear stations. The references not applicable to Byron have been deleted, however the numbering has been preserved for ease of reference management throughout the ODCM document; therefore, reference numbering is not sequential.

2.

U.S. Nuclear Regulatory Commission, Standard Radiological Effluent Technical Specifications for Pressurized Water Reactors, NUREG-0472, Rev. 3, Draft, January 1983 (frequently revised).

4.

U.S. Nuclear Regulatory Commission, Measuring, Evaluating, and Reportinaq Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants, Regulatory Guide 1.21. Revision 1, June 1974.

Page 11.1-10

CY-BY-1 70-301 Revision 8

5.

U.S. Nuclear Regulatory Commission, Onsite Meteorological Programs, Regulatory Guide 1.23, Safety Guide 23, February 17, 1972.

6.

U.S. Nuclear Regulatory Commission, Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50 Appendix I, Regulatory Guide 1.109, Rev. 1, October 1977.

7.

U.S. Nuclear Regulatory Commission, Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Liaqht-Water-Cooled Reactors, Regulatory Guide 1.111, Rev. 1, July 1977.

8.

U.S. Nuclear Regulatory Commission, Calculation of Releases of Radioactive Materials in Gaseous and Liguid Effluents from Light-Water-Cooled Power Reactors, Regulatory Guide 1.112, Rev. 0-R, April 1976; reissued May 1977.

9.

U.S. Nuclear Regulatory Commission, Estimating Aquatic Dispersion of Effluents from Accidental and Routine Reactor Releases for the Purpose of Implementing Appendix I, Regulatory Guide 1.113, Rev. 1, April 1977.

10.

U.S. Nuclear Regulatory Commission, Programs for Monitoring Radioactivity in the Environs of Nuclear Power Plants, Regulatory Guide 4.1, Rev. 1, April 1975.

11.

U.S. Nuclear Regulatory Commission, Preparation of Environmental Reports for Nuclear Power Stations, Regulatory Guide 4.2, Rev. 2, July 1976.

12.

U.S. Nuclear Regulatory Commission, Environmental Technical Specifications for Nuclear Power Plants, Regulatory Guide 4.8, Rev. 1, December 1975. (See also the related Radiological Assessment Branch Technical Position, Rev. 1, November 1979.)

13.

U.S. Nuclear Regulatory Commission, Quality Assurance for Radiological Monitoring Programs (Normal Operations)--Effluent Streams and the Environment, Regulatory Guide 4.15, Rev. 1, February 1979.

14.

U.S. Nuclear Regulatory Commission, Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants, edited by J. S. Boegli et al. NUREG-01 33, October 1978.

15.

U.S. Nuclear Regulatory Commission, XOQDOQ: Computer Pro-gram for the Meteorological Evaluation of Routine Effluent Releases at Nuclear Power Stations, J. F.

Sagendorf et al. NUREG/CR-2919, PNL-4380, September 1982.

16.

U.S. Nuclear Regulatory Commission, Radiological Assessment, edited by J. E. Till and H. R. Meyer, NUREG/CR-3332, ORNL-5968, September 1983.

17.

U.S. Nuclear Regulatory Commission, Standard Review Plan, NUREG-0800, July 1981.

18.

U.S. Atomic Energy Commission, Meteorology and Atomic Energy 1968, edited by D. H.

Slade, TID-21940, July 1968.

Page 11.1-11

CY-BY-170-301 Revision 8

19.

U.S. Atomic Energy Commission, Plume Rise, G. A. Briggs, TID-25075, 1969.

20.

U.S. Atomic Energy Commission, The Potential Radiological Implications of Nuclear Facilities in the Upper Mississippi River Basin in the Year 2000, WASH 1209, January 1973.

21.

U.S. Atomic Energy Commission, HASL Procedures Manual, Health and Safety Laboratory, HASL-300 (revised annually).

22.

U.S. Department of Energy, Models and Parameters for Environmental Radiological Assessments, edited by C. W. Miller, DOE/TIC-1 1468, 1984.

23.

U.S. Department of Energy, Atmospheric Science and Power Production, edited by D.

Randerson, DOE/TIC-27601, 1984.

24.

U.S. Environmental Protection Agency, Workbook of Atmospheric Dispersion Estimates, D. B. Turner, Office of Air Programs Publication No. AP-26, 1970.

25.

U.S. Environmental Protection Agency, 40CFR190 Environmental Radiation Protection Requirements for Normal Operations of Activities in the Uranium Fuel Cycle, Final Environmental Statement, EPA 520/4-76-016, November 1, 1976.

26.

U.S. Environmental Protection Agency, Environmental Analysis of the Uranium Fuel Cycle, EPA-520/9-73-003-C, November 1973.

27.

American Society of Mechanical Engineers, Recommended Guide for the Prediction of the Dispersion of Airborne Effluents, 1973.

28.

Eisenbud, M., Environmental Radioactivity, 3rd Edition, (Academic Press, Orlando, FL, 1987).

29.

Glasstone, S., and Jordan, W. H., Nuclear Power and Its Environmental Effects (American Nuclear Society, LaGrange Park, IL, 1980).

30.

International Atomic Energy Agency, Generic Models and Parameters for Assessing the Environmental Transfer of Radionuclides from Routine Releases, Safety Series, No. 57, 1982.

31.

National Council on Radiation Protection and Measurements, Radiological Assessment:

Predictingq the Transport, Bioaccumulation, and Uptake by Man of Radionuclides Released to the Environment, NCRP Report No. 76, March 15, 1984.

32.

American National Standards Institute, Guide to Sampling Airborne Radioactive Materials in Nuclear Facilities, ANSI N13.1-1969, February 19, 1969.

Page 11.1-12

CY-BY-170-301 Revision 8

33.

Institute of Electrical and Electronics Engineers, Specification and Performance of On-Site Instrumentation for Continuously Monitoring Radioactivity in Effluents, ANSI N13.10-1974, September 19, 1974.

34.

American National Standards Institute, Testing and Procedural Specifications for Thermoluminescence Dosimetry (Environmental Applications), ANSI N545-1975, August 20, 1975.

35.

American Nuclear Insurers, Effluent Monitoring, ANI/MAELU Engineering Inspection Criteria for Nuclear Liability Insurance, Section 5.1, Rev. 2, October 24, 1986.

36.

American Nuclear Insurers, Environmental Monitoring, ANI/MAELU Engineering Inspection Criteria for Nuclear Liability Insurance, Section 5.2, Rev. 1, March 23, 1987.

37.

American Nuclear Insurers, Environmental Monitoring Progqrams, ANI/MAELU Information Bulletin 86-1, June 9, 1986.

38.

Cember, H., Introduction to Health Physics, 2nd Edition (Pergamon Press, Elmsford, NY 1983).

41.

U.S. Nuclear Regulatory Commission, Branch Technical Position, Radiological Assessment Branch, Revision 1, November 1979. (This is a branch position on Regulatory Guide 4.8.)

43.

U.S. Nuclear Regulatory Commission, Calculation of Releases of Radioactive Materials in Gaseous and Liguid Effluents from Pressurized Water Reactors (PWR-GALE Code),

NUREG-0017, April 1976.

49.

U.S. Nuclear Regulatory Commission, Methods for Demonstrating LWR Compliance with the EPA Uranium Fuel Cycle Standard (40 CFR Part 190), NUREG-0543, February 1980.

50.

International Commission on Radiological Protection, Report of Committee Two on Permissible Dose for Internal Radiation, Recommendations of the International Commission on Radiological Protection, ICRP Publication 2, 1959.

51.

U.S. Nuclear Regulatory Commission, A-ge-Specific Radiation Dose Commitment Factors for a One-Year Chronic Intake, Battelle Pacific Northwest Laboratories, NUREG-0172, 1977.

52.

W. C. Ng, Transfer Coefficients for Prediction of the Dose to Man via the Forage-Cow-Milk Pathway from Radionuclides Released to the Biosphere, UCRL-51939.

53.

E. C. Eimutis and M. G. Konicek, Derivations of Continuous Functions for the Lateral and Vertical Atmospheric Dispersion Coefficients, Atmospheric Environment 6, 859 (1972).

54.

D. C. Kocher, Editor, Nuclear Decay Data for Radionuclides Occurring in Routine Releases from Nuclear Fuel Cycle Facilities, ORNL/NUREG/TM-102, August 1977.

Page 11.1-13

CY-BY-170-301 Revision 8

55.

R. L. Heath, Gamma-Ray Spectrum Catalog, Aerojet Nuclear Co., ANCR-1000-2, third or subsequent edition.

56.

S. E. Thompson, Concentration Factors of Chemical Elements in Edible Aquatic Organisms, UCRL-50564, Rev. 1, 1972.

57.

U.S. Nuclear Regulatory Commission, Instruction Concerning Risks from Occupational Radiation Exposure, Regulatory Guide 8.29, July 1981.

58.

Dresden Nuclear Power Station, Radioactive Waste and Environmental Monitoring, Annual Report 1987, March 1988.

59.

Reserved reference number

70.

D.C. Kocher, Radioactivity Decay Data Tables, DOE/TIC-1 1026, 1981.

71.

J. C. Courtney, A Handbook of Radiation Shielding Data, ANS/SD-76/14, July 1976.

75.

Sargent & Lundy, METWRSUM, S&L Program Number 09.5.187-1.0.

76.

Sargent & Lundy, Comments on CECo ODCM and List of S&L Calculations, Internal Office Memorandum, P. N. Derezotes to G. R. Davidson, November 23, 1988.

77.

Sargent & Lundy, AZAP, A Computer Program to Calculate Annual Average Offsite Doses from Routine Releases of Radionuclides in Gaseous Effluents and Postaccident X/Q Values, S&L Program Number 09.8.054-1.7.

78.

National Oceanic and Atmospheric Administration, A Program for Evaluating Atmospheric Dispersion from a Nuclear Power Station, J. F. Sagendorf, NOAA Technical Memorandum ERL ARL-42, Air Resources Laboratory, Idaho Falls, Idaho, May 1974.

79.

G. P. Lahti, R. S. Hubner, and J. C. Golden, Assessment of Gamma-Ray Exposures Due to Finite Plumes, Health Physics 41, 319 (1981).

80.

National Council of Radiation Protection and Measurements, Ionizing Radiation Exposure of the Population of the United States, NCRP Report No. 93, September 1, 1987.

82.

W. R. Van Pelt (Environmental Analysts, Inc.), Letter to J. Golden (CoinEd) dated January 3, 1972.

84.

U.S. Nuclear Regulatory Commission, Draft Generic Environmental Impact Statement on Uranium Milling, NUREG-0511, April 1979.

85.

U.S. Environmental Protection Agency, Environmental Analysis of the Uranium Fuel Cycle, Part I - Fuel Supply, EPA-520/9-73-003-B, October 1973.

Page 11.1-14

CY-BY-1 70-301 Revision 8

86.

U.S. Nuclear Regulatory Commission, Final Generic Environmental Statement on the Use of Recycle Plutonium in Mixed Oxide Fuel in Light Water Cooled Reactors, NUREG-0002, August 1976.

87.

U.S. Nuclear Regulatory Commission, Demographic Statistics Pertaining to Nuclear Power Reactor Sites, NUREG-0348, Draft, December 1977.

88.

Nuclear News 31, Number 10, Page 69 (August 1988).

89.

General Electric Company, Irradiated Fuel Storage at Morris Operation, Operating Experience Report, January 1972 through December 1982, K. J. Eger, NEDO-20969B.

90.

U.S. Nuclear Regulatory Commission, Generic Letter 89-01, "Guidance For The Implementation of Programmatic Controls For RETS In The Administrative Controls Section of Technical Specifications and the Relocation of Procedural Details of Current RETS to the Offsite Dose Calculation Manual or Process Control Progqram", January 1989.

92.

NRC Safety Evaluation Report (SER)/Idaho Notional Engineering Laboratory Technical Evaluation Report (TER) of the Commonwealth Edison Offsite Dose Calculation Manual (ODCM), Revision O.A, December 2,1991.

95.

U.S. Nuclear Regulatory Commission, Standards for Protection Against Radiation (1 OCFR20).

96.

U.S. Nuclear Regulatory Commission, Licensing of Production and Utilization Facilities (1 OCFR50).

97.

Federal Register, Vol. 57, No. 169, Monday, August 31, 1992, page 39358.

98.

Miller, Charles W., Models and Parameters for Environmental Radiological Assessments, U.S. Dept. of Energy, DE8102754, 1984, pages 32, 33, 48, and 49.

99.

Kocher, D. C., "Dose-Rate Conversion Factors For External Exposure To Photons and Electrons", Health Physics Vol. 45, No. 3 (September), pp. 665-686, 1983.

100.

U.S. Department of Health, Education and Welfare Public Health Service, Radiological Health Handbook, January 1970.

101.

ODCM Bases and Reference Document, rev.0, November, 1998.

103.

U.S. Nuclear Regulatory Commission, Generic Letter 79-041, September 17, 1979.

104.

Federal Register, Vol. 56, No. 98, Tuesday, May 21, 1991, page 23374, column 3.

105.

U.S. Nuclear Regulatory Commission, Offsite Dose Calculation Manual Guidance:

Standard Radiological Effluent Controls for Pressurized Water Reactors, NUREG-1301, April 1991.

Page 11.1-15

CY-BY-170-301 Revision 8 107.

U.S. Nuclear Regulatory Commission, LADTAP II - Technical Reference and Users Guide, NUREG-4013, April 1986.

108.

Holtec Report No. HI-2084113, Dose Versus Distance from a HI-STORM 100S Version B Containing the MPC-32 for Byron/Braidwood. Holtec International, 8/14/08.

109.

Exelon Letter RS-1 1-099, Request For License Amendment Regarding-Measurement Uncertainly Recapture (MUR) Power Uprate, June 23, 2011.

Page 11.1-16

CY-BY-1 70-301 Revision 8 Table 1 - 3 Miscellaneous Dose Assessment Factors: Environmental Parameters Parameter Value Comment Equation Basisa f___

0.76 4-11,4-12 A

fL 1.0 4-11,4-12 A

fp 1.0 4-13,4-15 A

fs 1.0 4-13,4-15 A

tb 262,800 30 years 4-9 C

hrs tf 48 hrs Cow Milk Pathway 4-13 A

tf 480 hrs Cow Meat Pathway 4-15 A

th 1440 hrs 60 days for produce 4-11 A

th 2160 hrs 90 days for produce 4-13,4-15 A

tL 24 hrs 1 day for leafy vegetables 4-11 A

QF 50 4-13, 4-14, 4-15, B

Kg/day 4-16 r

1.0 For lodines 4-11, 4-13, 4-15 A

r 0.2 For Particulates 4-11, 4-13, 4-15 A

Yp 0.7 4-13,4-15 A

Kg/m2 Ys 2.0 4-13,4-15 A

Kg/m2 Y,

2.0 4-11 A

Kg/m 2

xw 0.0021 4-11,4-13, 4-15 A

hr-1 H

8 gm/m5 Absolute Atmospheric Humidity 4-12, 4-14, 4-16 D

aBasis key:

A:

Reference 6, Table E-15.

B:

Reference 6, Table E-3.

C:

The parameter tb is taken as the midpoint of plant operating life (based upon an assumed 60 year plant operating lifetime).

D:

Reference 14, Section 5.3.1.3.

Page 11.1-17

CY-BY-170-301 Revision 8 Table 1 - 4 Stable Element Transfer Data Element H

Be C

F Na Mg Al P

Cl Ar K

Ca Sc Ti V

Cr Mn Fe Co Ni Cu Zn Ga Ge As Se Br Kr Rb Sr Y

Zr Nb Mo Tc Ru Rh Pd Cd In Sn Sb Ag Te I

Xe Cs Ba La Ce Pr Nd Ff Meat (d/kcq) 1.2E-02 1.5E-03 3.1 E-02 2.9E-03 3.OE-02 1.5E-03 1.5E-02 4.6E-02 2.9E-03 NA 1.8E-02 1.6E-03 2.4E-03 3.4E-02 2.8E-01 2.4E-03 8.OE-04 4.OE-02 1.3E-02 5.3E-02 8.OE-03 3.OE-02 1.5E-02 9.1 E-04 1.7E-02 7.7E-02 2.9E-03 NA 3.1 E-02 6.OE-04 4.6E-03 3.4E-02 2.8E-01 8.OE-03 4.OE-01 4.OE-01 1.5E-03 5.3E-02 3.OE-02 1.5E-02 9.1 E-04 5.OE-03 1.7E-02 7.7E-02 2.9E-03 NA 4.OE-03 3.2E-03 2.OE-04 1.2E-03 4.7E-03 3.3E-03 FM(COw)

Milk (d/L) 1.OE-02 3.2E-03 1.2E-02 1.4E-02 4.OE-02 3.2E-03 1.3E-03 2.5E-02 1.4E-02 NA 7.2E-03 1.1E-02 7.5E-06 5.OE-06 1.3E-03 2.2E-03 2.5E-04 1.2E-03 1.OE-03 6.7E-03 1.4E-02 3.9E-02 1.3E-03 9.9E-05 5.OE-04 1.OE-03 2.2E-02 NA 3.OE-02 8.OE-04 1.OE-05 5.OE-06 2.5E-03 7.5E-03 2.5E-02 1.OE-06 1.OE-02 6.7E-03 2.OE-02 1.3E-03 9.9E-05 2.OE-05 5.OE-02 1.OE-03 6.OE-03 NA 1.2E-02 4.OE-04 5.OE-06 1.OE-04 5.OE-06 5.OE-06 Reference 6

Footnote 1 6

Footnote 2 6

Footnote 1 Footnote 3 6

Footnote 2 NA 16 16 Footnote 4 Footnote 5 Footnote 6 6

6 6

6 6

6 6

Footnote 3 Footnote 7 Footnote 8 Footnote 9 Ft Footnote 2 ;FM from Ref. 16 NA 6

6 6

6 6

6 6

6 6

Footnote 10 Footnote 11 Footnote 3 Footnote 7 98 6

6 6

NA 6

6 6

6 6

6 Page 11.1-18

CY-BY-1 70-301 Revision 8 Table 1 - 4 (Cont'd)

Stable Element Transfer Data Ff FM (Cow)

Element Meat (d/kq)

Milk (d/L)

Reference Pm 2.9E-04 2.OE-05 16 Sm 2.9E-04 2.OE-05 16 Eu 2.9E-04 2.OE-05 16 Gd 2.9E-04 2.OE-05 16 Dy 2.9E-04 2.OE-05 16 Er 2.9E-04 2.OE-05 16 Tm 2.9E-04 2.OE-05 16 Yb 2.9E-04 2.OE-05 16 Lu 2.9E-04 2.OE-05 16 Hf 3.4E-02 5.OE-06 Footnote 5 Ta 2.8E-01 1.3E-03 FM - Ref.16; Ff -Footnote 6 W

1.3E-03 5.OE-04 6

Re 1.OE-01 1.3E-03 FM - Ref.16; Ff -Footnote 12 Os 2.2E-01 6.OE-04 Footnote 13 Ir 7.3E-03 5.5E-03 Footnote 14 Pt 5.3E-02 6.7E-03 Footnote 10 Au 1.3E-02 3.2E-02 Footnote 15 Hg 3.OE-02 9.7E-06 Fm - Ref.16; F1 -Footnote 11 TI 1.5E-02 1.3E-03 FM - Ref.16; Ff -Footnote 3 Pb 9.1 E-04 9.9E-05 98 Bi 1 7E-02 5.OE-04 98 Ra 5.5E-04 5.9E-04 98 Th 1.6E-06 5.OE-06 98 U

1.6E-06 1.2E-04 98 Np 2.OE-04 5.OE-06 6

Am 1.6E-06 2.OE-05 98 Notes:

1.

NA = It is assumed that noble gases are not deposited on the ground.

2.

Elements listed are those considered for 1 OCFR20 assessment and compliance.

Footnotes:

There are numerous Ff and FM values that were not found in published literature. In these cases, the periodic table was used in conjunction with published values. The periodic table was used based on a general assumption that elements have similar characteristics when in the same column of the periodic table. The values of elements in the same column of the periodic table, excluding atomic numbers 58-71 and 90-103, were averaged then assigned to elements missing values located in the same column of the periodic table. This method was used for all columns where there were missing values except column 3A, where there was no data, hence, the average of column 2B and 4A were used.

1.

Values obtained by averaging Reference 6 values of Ca, Sr, Ba and Ra.

2.

Ff value obtained by assigning the Reference 6 value for I. FM value obtained by averaging I (Ref. 6) and Br (Ref. 16).

3.

Ff values obtained by averaging Zn (Ref.6) and Pb (Ref. 98); there were no values for elements in the same column; an average is taken between values of columns 2B and 4A on the periodic table. FM values obtained by using the value for TI from Reference 16.

4.

Values obtained by averaging Reference 6 values of Y and La.

5.

Values obtained by assigning the Reference 6 value for Zr.

6.

Ft values obtained from Ref. 6 value for Nb. Fm values obtained by averaging values for Nb (Ref.6) and Ta (Ref. 16).

7.

Values obtained from the Reference 6 values for Pb.

8.

Values obtained from the Reference 6 values for Bi.

9.

Values obtained from the Reference 6 values for Te.

10.

Values obtained from the Reference 6 values for Ni.

11.

F1 values obtained from Ref. 6 values for Zn. Fm values obtained by averaging the Reference 6 values for Zn and Hg.

12.

Values obtained by averaging Reference 6 values for Mn, Tc, Nd and Reference 98 value for U.

13.

Values obtained by averaging Reference 6 values from Fe and Ru.

14.

Values obtained by averaging Reference 6 values from Co and Rh.

15.

Values obtained by averaging Reference 6 values from Cu and Ag.

Page 1I 1-19

CY-BY-170-301 Revision 8 Qwmn Chrc PAW Futtwe Process Radwaste Storage Building DAW Building (Warehouse #3)

Future DAW & 48 Pack Locations Restricted Ame Boundary ISFSI Pad m

nM4ie WLE _

I OFFSITE DOSE CALCULATION MANUAL BYRON STATION FIGURE 1-3 RESTRICTED AREA BOUNDARY Page 11.1-20

CY-BY-170-301 Revision 8 2.0 INSTRUMENTATION AND SYSTEMS 2.1 Liquid Effluents System Description A simplified liquid release flowpath diagram is provided in Figure 2-3.

A simplified liquid radwaste processing diagram is provided in Figure 2-2.

The liquid radwaste treatment system is designed and installed to reduce radioactive liquid effluents by collecting the liquids, providing for retention or holdup, and providing for treatment by demineralizer for the purpose of reducing the total radioactivity prior to release to the environment. The system is described in Chapter 11 of the Byron Updated Final Safety Analysis Report.

2.1.1 Release Tanks There are two radwaste release tanks (OWXOIT and OWX26T 30,000-gallon capacity each) that receive liquid waste before discharge to the Rock River.

2.1.2 Turbine Building Fire and Oil Sump The turbine building fire and oil sump receives water from selected turbine building sumps, the tendon tunnel sumps, and the diesel fuel oil storage sumps, all of which are normally non-radioactive but potentially contaminated. The effluent from this sump is monitored, and if radioactive contamination exceeds a predetermined level pump operation is automatically terminated. The water may then be sent to the liquid radwaste treatment system.

2.1.3 Condensate Polisher Sump The condensate polisher sump receives wastewater from the condensate polisher system, which is normally non-radioactive but potentially contaminated. The effluent from this sump is monitored and if radioactive contamination exceeds a predetermined level sump discharge is terminated and major condensate polisher inputs to the sump are automatically isolated. The water may then be sent to the liquid radwaste treatment system.

Page 11.2-1

CY-BY-1 70-301 Revision 8 2.2 Liquid Effluent Radiation Monitors Pertinent information on the Liquid Radioactive Effluent Monitors and associated control devices are shown in Table 2-1; additional information is provided in the Byron UFSAR Chapter 11.

2.2.1 Liquid Radwaste Effluent Monitor Monitor ORE-PRO01 is used to monitor all releases from the release tanks. On high alarm, the monitor automatically initiates closure of valves OWX-353 and OWX-869 to terminate the release.

2.2.2 Station Blowdown Monitor Monitor ORE-PR010 continuously monitors the circulating water blowdown. No control device is initiated by this channel.

2.2.3 Reactor Containment Fan Cooler (RCFC) and Essential Service Water (SX) Outlet Line Monitors.

Monitors 1RE-PR002, 2RE-PROO2, 1RE-PR003, and 2RE-PRO03 continuously monitor the RCFC and SX outlet lines. No control device is initiated by these channels.

2.2.4 Turbine Building Fire and Oil Sump Monitor Monitor ORE-PRO05 continuously monitors the fire and oil sump discharge. On high alarm the monitor automatically initiates an interlock to trip the discharge pumps, close valve 0OD030, and terminate the release.

2.2.5 Condensate Polisher Sump Monitor Monitor ORE-PRO41 continuously monitors the condensate polisher sump discharge. On high alarm, the monitor automatically initiates an interlock to trip the discharge pumps and terminate the release.

2.2.6 Component Cooling Water Monitors Monitors ORE-PRO09 (common), 1 RE-PRO09 (Unit 1), and 2RE-PRO09 (Unit 2) continuously monitor the component cooling water heat exchanger outlets. On high alarm ORE-PRO09 initiates closure of both component cooling water surge tank (CCWST) vents, 1 RE-PRO09 initiates closure of the Unit 1 CCWST vent, and 2RE-PRO09 initiates closure of the Unit 2 CCWST vent.

Page 11.2-2

CY-BY-170-301 Revision 8 2.3 Liquid Radiation Effluent Monitors Alarm and Trip Setpoints Alarm and trip setpoints of liquid effluent monitors at the principal release points are established to ensure that the limits of TRM Section 3.11.a are not exceeded in the unrestricted area.

Setpoint calculations normally consist of identified release mixtures, dilution factors, conversion factors (detector sensitivity), maximum release flow rates, and conservatism factors.

2.3.1 Station Blowdown Monitor During release, the monitor setpoint is found by solving equation 2-1 P <_ Cfw + (1.50 x CT) X (J,,,/J(FCW + F,,X))

(2-1)

P Release Setpoint

[lCi/ml]

1.50 Factor to account for minor fluctuations in count rate cCW Concentration of activity in the circulating water blowdown at the time of discharge ("Background reading")

[pCi/ml]

C Analyzed activity in the release tank (excluding tritium)[gCi/ml]

F*

Circulating Water Blowdown Rate

[gpm]

Frmax Maximum Release Tank Discharge Flow Rate

[gpm]

The flow rate from the radwaste discharge tank The release mixture used for the setpoint determination is the radionuclide mix identified in the release tank grab sample isotopic analysis.

2.3.2 Liquid Radwaste Effluent Monitor During release, the setpoint is established at 1.5 times the analyzed tank activity plus the background reading. However, per procedure, the maximum discharge flow rate is limited to a value that will result in less than 50% of 1 0*ECL at the discharge point. (See Section 2.3.2.1)

Page 11.2-3

CY-BY-1 70-301 Revision 8 2.3.2.1 Radwaste Tank Discharge Flow Rate Prior to each batch release, a grab sample is obtained.

The results of the analysis of the waste sample determine the discharge rate of each batch as follows:

F r 0.5( Fd',/Z(Ci /1O*ECL i))

(2-2)

The summation is over radionuclides i.

Fmax Maximum Permitted Discharge Flow Rate

[gpm]

The maximum permitted flow rate from the radwaste discharge tank based on radiological limits (not chemistry limits which may be more restrictive) d Fact Circulating Water Blowdown Rate

[gpm]

Ci Concentration of Radionuclide i in the Release Tank

[gCi/ml]

The concentration of radioactivity in the radwaste discharge tank based on measurements of a sample drawn from the tank.

ECL, Effluent Concentration Limit

[ACi/ml]

The concentration of radionuclide i given in Appendix B, Table 2, Column 2 to 10CFR20.1001 - 20.2402.

10 Multiplier 2.3.2.2 Release Mixture The release mixture used for the setpoint determination is the radionuclide mix identified in the release tank grab sample isotopic analysis.

2.3.2.3 Liquid Dilution Flow Rates Dilution flow rates are obtained from the main control board in the control room. If this information is unavailable, releases may continue for up to 30 days provided the dilution flow rates are estimated every 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> during the release, in accordance with TRM Table T 3.11.a-1.

Page 11.2-4

CY-BY-170-301 Revision 8 2.3.2.4 Projected Concentrations for Releases After determining F__ from Equation 2-2, RE compliance is verified using Equations 2-3 and 2-4.

CT =

+ Fact (2-3)

YX( C'] / 10

  • ECL i 1:< 1 (2-4)

The summation is over radionuclides i.

Ci Concentration of Radionuclide i in the Unrestricted Area[gCi/mL]

The calculated concentration of radionuclide i in the unrestricted area as determined by Equation 2-3.

CT Concentration of Radionuclide i in the Release Tank

[gCi/mL]

The concentration of radioactivity in the radwaste discharge tank based on measurements of a sample drawn from the tank.

ECLi Effluent Concentration Limit

[pCi/ml]

The concentration of radionuclide i given In Appendix B, Table 2, Column 2 to 10CFR20.1001 - 20.2402.

10 Multiplier Fni.x Maximum Release Tank Discharge Flow Rate

[gpm]

Fact Circulating Water Blowdown Rate

[gpm]

2.3.3 Other Liquid Effluent Monitors For all other liquid effluent monitors, including ORE-PRO01 and ORE-PRO10 when not batch releasing, setpoints are determined such that the concentration limits do not exceed 10 times the ECL value given in Appendix B, Table 2, Column 2 to 10CFR20.1001 - 20.2402 in the unrestricted area. Release mixtures are based on a representative isotopic mixture of the waste stream or inputs to the waste stream, or defaulted to the mix listed in Table 2-4.

Page 11.2-5

CY-BY-1 70-301 Revision 8 2.3.4 Conversion Factors The readouts for the liquid effluent monitors are in giCVml. The cpm to iiCi/ml conversion is determined for each monitor.

2.3.5 Allocation of Effluents from Common Release Points Radioactive liquid effluents released from either release tank (OWX01T or OWX26T) are comprised of contributions from both units. Under normal operating conditions, it is difficult to apportion the radioactivity between the units. Consequently, allocation is made evenly between units.

2.3.6 Solidification Of Waste/Process Control Program The process control program (PCP) contains the sampling, analysis, and formulation determination by which solidification of radioactive wastes from liquid systems is ensured.

2.4 Gaseous Effluents System Description A simplified HVAC and gaseous effluent flow diagram is provided in Figure 2-1. The principal release points for potentially radioactive airborne effluents are the two auxiliary building vent stacks (designated Stack 1 and Stack 2 in Figure 2-1). In the classification scheme of Section 4.1.4, each is classified as a vent release point. Engineered safety features atmospheric cleanup systems are not considered to be ventilation exhaust treatment system components.

2.4.1 Waste Gas Holdup System The waste gas holdup system is designed and installed to reduce radioactive gaseous effluents by collecting reactor coolant system off-gases from the reactor coolant system and providing for delay or holdup to reduce the total radioactivity by radioactive decay prior to release to the environment.

2.4.2 Ventilation Exhaust Treatment System Ventilation exhaust treatment systems are designed and installed to reduce gaseous radioiodine or radioactive material in particulate form in gaseous effluents by passing ventilation or vent exhaust gases through charcoal adsorbers and/or HEPA filters prior to release to the environment. Such a system is not considered to have any effect on noble gas effluents. The ventilation exhaust treatment systems are shown in Figure 2-1.

Engineered safety features atmospheric cleanup systems are not considered to be ventilation exhaust treatment system components.

Page 11.2-6

CY-BY-170-301 Revision 8 2.5 Gaseous Effluent Radiation Monitors Pertinent information on the Gaseous Effluent Radiation Monitors and associated control devices are shown in Table 2-2, additional information is provided in Byron UFSAR Chapter 11.

2.5.1 Auxiliary Building Vent Effluent Monitors Monitors 1 RE-PR028 (Unit 1) and 2RE-PR028 (Unit 2) continuously monitor the final effluent from the auxiliary building vent stacks.

Both vent stack monitors feature automatic noble gas monitoring, isokinetic sampling, grab sampling, and sampling for iodine, particulate, and tritium.

These monitors perform no automatic isolation or control functions.

2.5.2 Containment Purge Effluent Monitors Monitors 1 RE-PRO01 (Unit 1) and 2RE-PRO01 (Unit 2) continuously monitor the effluent from the Unit 1 and Unit 2 containments, respectively. When airborne radioactivity in the containment purge effluent stream exceeds a specified level station personnel will follow established procedures to terminate the release by manually activating the containment purge valves. Additionally, the auxiliary building vent effluent monitors provide an independent, redundant means of monitoring the containment purge effluent.

These monitors perform no automatic isolation or control functions.

Monitors 1 RE-AR01 1, 2RE-AR01 1, 1 RE-AR012 and 2RE-AR01 2 continuously monitor the containment atmosphere for radioactive gas and particulates. On high alarm during a containment purge, these monitors will automatically terminate the purge.

Page 11.2-7

CY-BY-1 70-301 Revision 8 2.5.3 Waste Gas Decay Tank Monitors Monitors ORE-PRO02A and ORE-PRO02B continuously monitor the noble gas activity released from the gas decay tanks.

On high alarm, the monitors automatically initiate closure of the valve OGW104 thus terminating the release.

2.5.4 Gland Steam and Condenser Air Ejector Monitors Monitors 1 RE-PR027 and 2RE-PR027 continuously monitor the condenser air ejector gas from Units 1 and 2, respectively. This monitor performs no automatic isolation or control functions.

2.5.5 Radwaste Building Ventilation Monitor Monitor ORE-PR026 continuously monitors radioactivity in the radwaste building ventilation system. On high alarm, ORE-PR026 initiates isolation of the radwaste building ventilation system.

2.5.5.1 Miscellaneous Ventilation Monitors Monitor ORE-PRO03 continuously monitors radioactivity in the ventilation exhaust from the laboratory fume hoods. This monitor performs no automatic isolation or control functions.

2.6 Gaseous Effluent Monitor Alarm and Trip Setpoints 2.6.1 Auxiliary Building Vent Effluent Monitors The setpoints for the low range noble gas channel are conservatively established at 2.5% of the maximum permissible release rate for the high alarm and 0.25% of the maximum release rate for the alert alarm.

The setpoints for the high range noble gas channel are conservatively established at 50% of the maximum permissible release rate for the high alarm and 5% of the maximum release rate for the alert alarm.

The setpoint methodology must ensure simultaneous releases do not exceed the off-site dose rate limits set forth in TRM3.1 1. Setpoints can be adjusted based upon operational requirements with the restriction that the sum of the percentages between the Unit 1 and Unit 2 noble gas channels does not exceed 90% of the maximum permissible release rate.

Page 11.2-8

CY-BY-1 70-301 Revision 8 2.6.2 Containment Purge Effluent Monitors Under normal conditions when the containment atmosphere monitor gas detector is operational, the setpoints are established at 1.25 times the containment noble gas activity during purge based on a grab sample obtained from the rad monitor.

When the containment atmosphere monitor gas detector is not operational, the setpoints are established at 1.5 times the containment noble gas activity during purge to prevent a spurious alarm based on a grab sample that may not be as representative of the containment atmosphere as monitored by the containment purge rad monitor during non-release periods.

2.6.3 Waste Gas Decay Tank Effluent Monitors The setpoints are established at 1.25 times the analyzed waste gas tank activity during release.

2.6.4 Gaseous Effluent Release Limits Alarm and trip setpoints of gaseous effluent monitors are established to ensure that the release rate limits of TRM Section 3.11.f are not exceeded. The release limits are found by solving Equations 2-5 and 2-6 for the total allowed release rate of vent releases, Qt.

(x/Q)T,,K, fl <500 mrem/yr (2-5)

Qt_,f{L, (z/Q), + (1.11)M,(X/Q)T 1< 3000 mrem/yr (2-6)

The summations are over noble gas radionuclides i.

fl Fractional Radionuclide Composition The release rate of noble gas radionuclide i divided by the total release rate of all noble gas radionuclides.

Qv Total Allowed Release Rate, Vent Release

[jiCi/sec]

The total allowed release rate of all noble gas radionuclides released as vent releases.

The remaining parameters in Equation 2-5 have the same definitions as in Equation 4-1 of Part II Section 4. The remaining parameters in Equation 2-6 have the same definition as in Equation 4-2 of Part II Section 4.

Page 11.2-9

CY-BY-170-301 Revision 8 Equation 2-5 is based on Equation 4-1 of Section 4 and the RE restriction on whole body dose rate (500 mrem/yr) due to noble gases released in gaseous effluents (see Part II Section 4.2.1.1). Equation 2-6 is based on Equation 4-2 of Section 4 and the RE restriction on skin dose rate (3000 mrem/yr) due to noble gases released in gaseous effluents (see Part II Section 4.2.1.2).

Since the solution to Equation 2-6 is more conservative than the solution to Equation 2-5, the value of Equation 2-6 (1.02 x 107.tCi/sec) is used as the limiting noble gas release rate. During evolutions involving releases from the containment or waste gas decay tanks, the total station release rate is procedurally limited such that the maximum permissible release rate is not exceeded.

2.6.5 Release Mixture In the determination of alarm and trip setpoints, the radioactivity mixture in exhaust air is assumed to have the radionuclide composition of Table 2-3.

2.6.6 Conversion Factors.

The response curves used to determine the monitor count rates are based on the sensitivity to Xe-i133 for conservatism.

2.6.7 HVAC Dilution Flow Rates The plant vent stack flow rates are obtained from the RM-1 1 (or equivalent) console in the control room. If the values cannot be obtained from RM-1 1 (or equivalent), flow rates can be estimated from the operating fan combinations.

2.6.8 Allocation of Effluents from Common Release Points Radioactive gaseous effluents released from the auxiliary building, miscellaneous ventilation systems and the gas decay tanks are comprised of contributions from both units. Consequently, allocation is made evenly between units.

2.6.9 Dose Projections for Batch Releases The 10CFR20 dose limits have been converted into a station administrative release rate limit using the methodology in the ODCM.

Compliance is verified prior to each release. Doses are calculated after purging the containment or venting the waste gas decay tanks.

Per procedure, representative samples are obtained and analyzed, and the doses calculated on a monthly basis to verify compliance with 10CFR50.

Page 11.2-10

CY-BY-170-301 Revision 8 Table 2-1 Liquid Radioactive Effluent Monitors Alarm I

ISetpoint Channel Monitor Description Sampling Locations Effluent Control Functions Used Radwaste Release Common release point from Radwaste I

ORE-PR001 Tank Monitor Release Tanks OWX01T, OWX26T Radwaste release termination Yes Station Blowdown I

ORE-PR010 Monitor

.Circulating Water Blowdown None No 1RE-PRO02 Reactor Containment 2RE-PRO02 Fan Cooler and 1 RE-PRO03 Essential Service Water 2RE-PRO03 Outlet Line Monitors RCFC and SX outlet lines None No Turbine Building Fire Terminates release from ORE-PRO05 and Oil Sump Monitor Fire and Oil Sump discharge Fire and Oil Sump Yes Condensate Polisher Terminates release from ORE-PRO41 I

Sump Monitor Condensate Poisher Sump dischareg Condensate Polisher Sump Yes ORE-PRO09: CCW Heat Exchangers, ORE-PRO09: Closes both CCW surge common discharge tank vents 1 RE-PRO09: Unit 1 CCW Heat Exchanger 1 RE-PRO09: Closes Unit 1 CCW ORE-PRO09 discharge surge tank vent 1 RE-PRO09 Component Cooling 2RE-PR009: Unit 2 CCW Heat Exchanger 2RE-PRO09: Closes Unit 2 CCW 2RE-PRO09 Water (CCW) Monitors discharge surge tank vent Yes Page 11.2-11

CY-BY-1 70-301 Revision 8 Table 2-2 Gaseous Radioactive Effluent Monitors Alarm Setpoint Channel I Monitor Description Sampling Locations Effluent Control Functions i

Used Final effluent from auxiliary building vent stack IRE-PR028 Auxiliary Building Vent from Unit 1 (1RE-PR028) and 2RE-PR028 i

Effluent Monitors from Unit 2 (2RE-PR028)

None Yes 1RE-PRO01 Containment Purge Effluent from Unit 1 Containment (1RE-PRO01) 2E-PRO1 Effluent Monitors luet from Unit 2 Containment 2RE-PRO01)

None 1RE-AR011 T Unit 1 Containment (1RE-AROl1, 1RE-AR012) 2RE-AR01 1 Reactor Containment Unit 2 Containment (2RE-AR01 1, 2RE-AR01 2) 1RE-AR012 Particulate and Gas Note: not effluent monitors, but have effluent 2RE-AR01 2 Monitors control functions Terminate containment purge Yes ORE-PRO02A Waste Gas Decay Tank Closes valve OGW104, ORE-PRO02B Monitors Release line from Waste Gas Decay Tanks terminates release Yes Gland Steam and Condenser Air Ejector (CAE) gas from Unit 1 1 RE-PR027 Condenser Air Ejector (1 RE-PR027) and 2RE-PR027 I

Monitors CAE gas from Unit 2 (2RE-PR027)

None No I

Radwaste Building Isolates Radwaste Building ORE-PR026 Ventilation Radwaste Building Ventilation System ventilation system Yes Laboratory Fume Hood ORE-PRO03 Exhaust Monitor Common line from laboratory fume hoods None No Page 11.2-12

CY-BY-170-301 Revision 8 Table 2-3 Assumed Composition of the Byron Station Noble Gas Effluent Isotope Percent of Effluent Ar-41 0.89 Kr-85m 0.18 Kr-85 24.9 Kr-87 0.04 Kr-88 0.28 Xe-1 31 m 1.42 Xe-133m 0.57 Xe-133 71.1 Xe-135 0.53 Xe-138 0.04 Page 11.2-13

CY-BY-1 70-301 Revision 8 Table 2-4 Assumed Composition of the Byron Station Liquid Effluent Isotope Concentration Isotope Concentration (uCVmi)

(uCi/mi)

H-3 1.16E-05 Ag-110m 1.70E-11 Cr-51 2.39E-12 Te-127 5.40E-13 Mn-54 3.86E-11 Te-129m 1.78E-12 Fe-55 2.08E-12 Te-129 1.1 6E-12 Fe-59 1.35E-12 Te-131 m 1.27E-12 Co-58 1.74E-10 Te-132 2.39E-1 1 Co-60 3.40E-10 1-130 4.24E-12 Br-83 6.59E-13 1-131 3.09E-09 Rb-86 1.81 E-12 1-132 6.95E-11 Sr-89 5.02E-13 1-133 1.43E-09 Zr-95 5.40E-11 1-135 1.66E-10 Nb-95 7.72E-1 1 Cs-1 34 1.08E-09 Mo-99 7.72E-11 Cs-136 2.66E-10 Tc-99m 8.88E-1 1 Cs-1 37 1.35E-09 Ru-103 5.40E-12 Ce-144 2.01E-10 Ru-1 06 9.26E-1 1 Np-239 8.88E-1 3 Page 11.2-14

AUXILLARY CY-BY-1 70-301 Revision 8 N+O C, *0 p-9 ELEV. 20O0-I *

  • l*-ABOVE GRADE STATE OF S'T III M A IN IL L N O IS T I S T=

H PURGE STACK MONITOR E

-1r"-

ITOR H

MINI PURGE 4.000 PR,.8 2RE-PR028

+.oo F

43;900

-I H G H POST LOCA PURGE N

0 PR030 2RE-PR030 (Nom 2)

PRO01 CONTAINMENT UNIT 2 N

0 F

43,900 PROW Stack Stack 1

2 HH p-t~3 135,900-4 5*,400 1 25,400 U

I, C H Only Dudng diSChargf; I

ORE-PR02 II 135,900 H

G H~1,000 oRE-PR025 H

G H

H 9,230 ORE-PRO0S 9,000 Figure 2-1 SIMPLIFIED HVAC AND GASEOUS EFFLUENT FLOW DIAGRAM (SHEET 1 OF 2)

Page 11.2-15

CY-BY-170-301 Revision 8 UNIT 1 CON DENSOR FL 2,500 DURING UNIT 1 STARTUP HOGGING PUMP----.J------------

GLAND STEAM 1,400 H

1,432 L

F 0

6,000 (NOTE 3) 4 P

2

-r IH G

G H

TURBINE BUILDING OFFGAS FILTER UNIT

-i GENERAL AREA I(ELEVATION 451 FEET)

UNIT 2 CONDENSOR 2,500 DURING UNIT 2 STARTUP HOGGING PUMP GLAND STEAM 1,400 1

CONDENSER M

2RE-PRO27 STEAM JET AIR 32 EJECTOR STACK I

STACK 2

H 1,432 F

0 SOLID RADWASTE F AL ORE-PP DRUMMING STATION ý _

2ý0JR&PRO14 3,100 4 ---------------------

VOLUME REDUCTION r - - - -(ýý 4

H G

G H

L -

[ý ORE-PRO40 LEGEND NOTES NORMAL OR FREQUENT FLOW PATH OCCASIONAL FLOW PATH A

CONTAIMENT ATMOSPHERE RADIATION MONITOR C

CHARCOAL FILTER F

REFUELING G

NOBLE GAS RADIATION MONITOR H

HEPA FILTER M

THREE-CHANNEL RADIATION MONITOR FOR PARTICULATE, IODINE, AND NOBLE GAS (OFFLINE)

N NORMAL OPERATION P

PARTICULATE MONITOR (OFFLINE)

R HYDROGEN RECOMBINER S

NORMAL RANGE STACK RADIATION MONITOR (PARTICULATE, IODINE, AND NOBLE GAS)

W WIDE-RANGE STACK NOBLE GAS RADIATION MONITOR

1. USED INTERMITTENTLY To VENT CONTAINMENT DURING NORMAL OPERATION
2. USED ONLY DURING POST ACCIDENT OPERATION
3. FILTER UNIT OPERATES ONLY WHEN HIGH RADIATION IS DETECTED IN OFFGAS SYSTEM EFFLUENT DISCHARGE OFFSITE DOSE CALCULATION MANUAL BYRON STATION Figure 2-1 SIMPLIFIED HVAC AND GASEOUS EFFLUENT FLOW DIAGRAM (SHEET 2 OF 2)

Page 11.2-16

CY-BY-1 70-301 Revision 8 UNIT 1 UNIT 1 BLOWDOWN 1LOWDOWN SLOWDOWN MIXED BED DEMINERALIZER PR.U R

DEMINERALIZER AFTER FILTER STEAM 1

SLOWDOWN

-P CONDENS GENERATOR CONDENSE!Rj STORAGE 1 BLOW DO WN UNIT 2 UNIT 2 BLOWDOWN 3LOWDOWN LOWDOWN SLOWDOWN MIXED BED DEMINERALIZERMOIR UNIT 2 P

A DEMINERALIZER AFTER FILTER TANS(

TO UNIT 2 UTEAM 2NIT

CONDENS, STEAM R

LOWDOWN RELEASE TANK rSTORAGE 1 GENERATOR 1CONDENSER SLOW DOWN Figure 2-2 Simplified Liquid Radwaste Processing Diagram Page 11.2-17

CY-BY-170-301 Revision 8 IRE-PR002 LEGEND L

Liquid Radwaste Monitor Natural DraftCooling Tower

~

Essential ServiceWater CoolingT ower Figure 2-3 Liquid Release Flow Path Page 11.2-18

CY-BY-1 70-301 Revision 8 3.0 LIQUID EFFLUENTS 3.1 Liquid Effluent Releases - General Information 3.1.1 The design objectives of 10CFR50, Appendix I and RE provide the following limits on the dose to a member of the public from radioactive materials in liquid effluents released from each reactor unit to restricted area boundaries:

" During any calendar quarter, less than or equal to 1.5 mrem to the total body and less than or equal to 5 mrem to any organ.

" During any calendar year, less than or equal to 3 mrem to the total body and less than or equal to 10 mrem to any organ.

3.1.2 The organ doses due to radioactivity in liquid effluents are also used as part of the 40CFR190 compliance and are included in the combination of doses to determine the total dose used to demonstrate 10CFR20 compliance. (See Section 5.0, Total Dose) 3.1.3 Dose assessments for 10CFR50 Appendix I compliance are made for four age groups (adult, teenager, child, infant) using NUREG 0133 (Reference 14) methodology and Regulatory Guide 1.109 (Reference 6) dose conversion factors.

3.1.4 To limit the consequences of tank overflow, Technical Specification 5.5.12 limits the quantity of radioactivity that may be stored in unprotected outdoor tanks to 10 Curies.

Unprotected tanks are tanks that are not surrounded by liners, dikes, or walls capable of holding the tank contents and that do not have tank overflows and surrounding area drains connected to the liquid radwaste treatment system.

The specific objective is to provide assurance that in the event of an uncontrolled release of a tank's contents, the resulting radioactivity concentrations beyond the unrestricted area boundary, at the nearest potable water supply and at the nearest surface water supply, will be less than the limits of 1 OCFR20 Appendix B, Table 2; Column 2.

3.1.5 Cases in which normally non-radioactive liquid streams (such as the Service Water) are found to contain radioactive material are non-routine and will be treated on a case specific basis if and when this occurs. Since the station has sufficient capacity to delay a liquid release for reasonable periods of time, it is expected that Page 11.3-1

CY-BY-170-301 Revision 8 planned releases will not take place under these circumstances.

Therefore, the liquid release setpoint calculations need not and do not contain provisions for treating multiple simultaneous release pathways.

3.1.6 Radioactive liquid effluents released from either release tank (OWX01 T or OWX26T) are comprised of contributions from both units. Under normal operating conditions, it is difficult to apportion the radioactivity between the units. Consequently, allocation is made evenly between units.

3.2 Liquid Effluent Concentrations 3.2.1 One method of demonstrating compliance to the requirements of 10CFR20.1301 is to demonstrate that the annual average concentrations of radioactive material released in gaseous and liquid effluents do not exceed the values specified in 10CFR20 Appendix B, Table 2, Column 2. (See 10CFR 20.1302(b)(2).)

However, as noted in Section 5.5, this mode of 10CFR20.1301 compliance has not been elected.

As a means of assuring that annual concentration limits will not be exceeded, and as a matter of policy assuring that doses by the liquid pathway will be ALARA; RE provides the following restriction:

"The concentration of radioactive material released in liquid effluents to unrestricted areas shall be limited to ten times the concentration values in Appendix B, Table 2, Column 2 to 10CFR20.1001-20.2402."

This also meets the requirement of Station Technical Specifications and RE.

3.2.2 According to the footnotes to 10CFR20 Appendix B, Table 2, Column 2, if a radionuclide mix of known composition is released, the concentrations must be such that where the summation is over radionuclide i.

CI Radioactivity Concentration in Liquid Effluents to the Unrestricted Area [QCi/ml]

Page 11.3-2

CY-BY-1 70-301 Revision 8 Concentration of radionuclide i in liquid released to the unrestricted area.

ECL, Effluent Concentration Limit in Liquid Effluents Released to the Unrestricted Area [gCi/ml]

The allowable annual average concentration of radionuclide i in liquid effluents released to the unrestricted area. This concentration is specified in 10CFR20 Appendix B, Table 2, Column 2. Concentrations for noble gases are different and are specified in the stations' Technical Specifications and RE.

10 Multiplier to meet the requirements of Technical Specifications.

If either the identity or concentration of any radionuclide in the mixture is not known, special rules apply. These are given in the footnotes in 10CFR20 Appendix B, Table 2, Column 2.

3.2.3 When radioactivity is released to the unrestricted area with liquid discharge from a tank (e.g., a radwaste discharge tank), the concentration of a radionuclide in the effluent is calculated as follows:

Waste Flow (3-2)

Dilution Flow C1 Concentration of radionuclide i in liquid released to the unrestricted area. [gCi/ml]

Cit Concentration in the Discharge Tank

[RCi/mI]

Measured concentration of radionuclide I in the discharge tank.

The RE and Technical Specifications require a specified sampling and analysis program to assure that liquid radioactivity concentrations at the point of release are maintained within the required limits. To comply with this provision, samples are analyzed in accordance with the radioactive liquid waste (or effluent) sampling and analysis program in the TRM 3.11.c. Radioactivity concentrations in tank effluents are determined in accordance with Equation 3-2. Comparison with the Effluent Concentration Limit is made using Equation 3-1.

Page 11.3-3

CY-BY-170-301 Revision 8 3.3 Liquid Effluent Dose Calculation Requirements 3.3.1 RE require determination of cumulative and projected dose contributions from liquid effluents for the current calendar quarter and the current calendar year at least once per 31 days. (See TRM Chapter 3.11.)

For a release attributable to a processing or effluent system shared by more than one reactor unit, the dose due to an individual unit is obtained by proportioning the effluents among the units sharing the system. The allocation procedure is specified in section 3.1.6.

3.3.2 Operability and Use of the Liquid Radwaste Treatment System The design objectives of 10CFR50, Appendix I, RE and Technical Specifications require that the liquid radwaste treatment system be operable and that appropriate portions be used to reduce releases of radioactivity when projected doses due to the liquid effluent from each reactor unit to restricted area boundaries exceed either of the following (see TRM Chapter 3.11, RE);

  • 0.06 mrem to the total body in a 31-day period.
  • 0.2 mrem to any organ in a 31-day period.

3.4 Dose Methodology 3.4.1 Liquid Effluent Dose Method: General The dose from radioactive materials in liquid effluents considers the contributions for consumption of fish and potable water. All of these pathways are considered in the dose assessment unless demonstrated not to be present. While the adult is normally considered the maximum individual, the methodology provides for dose to be calculated for all four age groups. The dose to each organ (and to the total body) is calculated by the following expression:

Dq

= F At AC, (3-3) p I

The summation is over exposure pathways p and radionuclides i.

al Organ and Total Body Dose Due to Liquid Effluents [mrem]

Page 11.3-4

CY-BY-170-301 Revision 8 Dose to organ j (including total body) of age group a due to radioactivity in liquid effluents.

F Near Field Average Dilution Factor [dimensionless]

Dilution in the near field averaged over the period of interest.

Defined as:

F =

Waste Flow (3-4)

Dilution Flow x Z Waste Flow Liquid Radioactive Waste Flow [gpm]

The average flow during disposal from the discharge structure release point into the receiving water body.

Dilution Flow Dilution Water Flow During Period of Interest [gpm]

Z Discharge Structure Mixing Factor [dimensionless]

Site-specific factor to account for the mixing effect of the discharge structure. The factor addresses the dilution that occurs in the near field between the discharge structure and the body of water containing the fish in the liquid ingestion pathway (See section 3.5.5.2).

At Duration of Release [hrs]

C1 Average Radionuclide Concentration [gCVml]

Average concentration of radionuclide I, in the undiluted liquid effluent during time period At.

Aalp, Site-Specific Liquid Dose Factor [(mrem/hr)/(ptCi/ml)]

Site-specific dose factor for age group a, nuclide i, liquid pathway p and organ j. The pathways included are potable water and fish ingestion. Aaipj is defined for these pathways in the following sections. Values for Aaipj are provided in Part II Section 3.5 of this ODCM.

Page 11.3-5

CY-BY-170-301 Revision 8 3.4.2 Potable Water Pathway The site-specific potable water pathway dose factor is calculated by the following expression:

A.,(PW)j = ko OFL.,!

(3-5)

Where:

Aal(PW)l Site-Specific Dose Factor for Potable Water Pathway

[(mrem/hr)/(gCi/ml)]

Site-specific potable water ingestion dose factor for age group a, nuclide i and organ j.

ko Conversion Constant (1.14E05) [(yr-pCi-ml)/(hr-gCi-I)]

Units constant to convert years to hours, pCi to jiCi and liters to ml.

UaW Potable Water Consumption Rate [I/yr]

Potable water consumption rate for age group a. Taken from Table E-5 of Regulatory Guide 1.109.

Dw Potable Water Dilution Factor [dimensionless]

Dilution factor from the near field area within one-quarter mile of the release point to the potable water intake (See section 3.5.5.1).

DFLa 81 Ingestion Dose Conversion Factor [mrem/pCi]

Ingestion dose conversion factor for age group a, nuclide i and organ j. Converts pCi ingested to mrem. Taken from Tables E-1 1 though E-14 of Regulatory Guide 1.109. The value for H-3 is taken from NUREG 4013 (Reference 107).

Page 11.3-6

CY-BY-170-301 Revision 8 3.4.3 Fish Ingestion Pathway The site-specific fish ingestion pathway dose factor is calculated by the following expression:

Aal(Flsh)l = koU.BFDFL 1,1 (36)

Where:

Aai(Fish)j Site-Specific Dose Factor for Fish Ingestion Pathway

[(i mrem/h r)/(gjC i/m I)]

Site-specific fish ingestion dose factor for age group a, nuclide i and organ j.

UaF Fish Consumption Rate

[kg/yr]

Fish consumption rate for age group a. Taken from Table E-5 of Regulatory Guide 1.109.

BF, Bioaccumulation Factor

[(pCi/kg)/(pCi/I)]

Bioaccumulation factor for nuclide i in fresh water fish.

Taken from Table 3-8.

All other terms have been previously defined.

3.4.4 Offsite doses due to projected releases of radioactive materials in liquid effluents are calculated using Equation 3-3. Projected radionuclide release concentrations are used in place of measured concentrations, CQ.

3.5 Site Specific Dose Factors and Bioaccumulation Factors 3.5.1 There are no public potable water intakes on the Rock River downstream of the station.

3.5.2 There is no irrigation occurring on the Rock River downstream of the station.

3.5.3 Recreation includes one or more of the following: boating, water-skiing, swimming, and sport fishing.

Page 11.3-7

CY-BY-1 70-301 Revision 8 3.5.4 According to Section 2.4.1.2 and Figure 2.4-5 of the Byron Environmental Report, there are four downstream dams on the Rock River within approximately 50 miles of the station one at Oregon, one at Dixon and two at Sterling.

3.5.5 Water and Fish Ingestion Parameters 3.5.5.1 DW= 10 (potable water dilution factor, dimensionless) 3.5.5.2 Z = 32 (discharge structure mixing factor, dimensionless) 3.5.6 Site-specific dose factors for potable water consumption are shown in Table 3-1 for adult, Table 3-2 for teen, Table 3-3 for child, and Table 3-4 for infant age groups. These tables include dose factors for the bone, liver, total body, thyroid, kidney, lung, and GI (lower large intestines).

3.5.7 Site-specific dose factors for fish ingestion are shown in Table 3-5 for adult, Table 3-6 for teen, and Table 3-7 for child age groups.

These tables include dose factors for the bone, liver, total body, thyroid, kidney, lung, and GI (lower large intestines).

Page 11.3-8

CY-BY-170-301 I Revision 8 Table 3-1 Site Specific Potable Water Dose Factors for Adult Age Group Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI H-3 O.OOE+00 4.98E-01 4.98E-01 4.98E-01 4.98E-01 4.98E-01 4.98E-01 Na-24 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+O1 1.41E+O1 1.41E+O1 Cr-51 O.OOE+00 O.OOE+00 2.21E-02 1.32E-02 4.88E-03 2.94E-02 5.57E+00 Mn-54 O.OOE+00 3.80E+O1 7.26E+00 0.00E+00 1.13E+01 O.OOE+00 1.17E+02 Mn-56 O.OOE+00 9.57E-01 1.70E-01 0.00E+00 1.22E+00 O.OOE+00 3.05E+01 Fe-55 2.29E+01 1.58E+01 3.69E+00 O.OOE+00 O.OOE+0O 8.82E+00 9.07E+00 Fe-59 3.61E+01 8.49E+01 3.25E+01 O.OOE+00 O.OOE+00 2.37E+O1 2.83E+02 Co-58 O.OOE+00 6.20E+00 1.39E+01 O.OOE+00 O.OOE+00 O.OOE+00 1.26E+02 Co-60 O.OOE+00 1.78E+01 3.93E+01 O.OOE+00 O.OOE+00 O.OOE+00 3.35E+02 Ni-63 1.08E+03 7.50E+01 3.63E+01 O.OOE+00 O.OOE+00 O.OOE+00 1.56E+01 Ni-65 4.39E+00 5.71E-01 2.60E-01 O.OOE+00 O.OOE+00 O.OOE+00 1.45E+01 Cu-64 O.OOE+00 6.93E-01 3.25E-01 O.OOE+00 1.75E+00 O.OOE+00 5.91E+01 Zn-65 4.03E+01 1.28E+02 5.79E+01 O.OOE+00 8.57E+0O1 O.OOE+00 8.07E+01 Zn-69 8.57E-02 1.64E-01 1.14E-02 O.OOE+00 1.07E-01 O.OOE+00 2.46E-02 Br-83 O.OOE+00 O.OOE+00 3.35E-01 O.OOE+00 O.OOE+00 O.OOE+00 4.82E-01 Br-84 O.OOE+00 O.OOE+00 4.34E-01 O.OOE+00 O.OOE+00 O.OOE+00 3.40E-06 Br-85 O.OOE+00 O.OOE+00 1.78E-02 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-86 O.OOE+00 1.76E+02 8.18E+O1 O.OOE+00 O.OOE+00 O.OOE+00 3.46E+O1 Rb-88 O.OOE+00 5.03E-01 2.67E-01 O.OOE+00 O.OOE+00 O.OOE+00 6.96E-12 Rb-89 O.OOE+00 3.34E-01 2.35E-01 O.OOE+00 O.OOE+00 O.OOE+00 1.94E-14 Sr-89 2.56E+03 O.OOE+00 7.36E+01 O.OOE+00 O.OOE+00 O.OOE+00 4.11E+02 Sr-90 7.25E+04 O.OOE+00 1.46E+03 O.OOE+00 O.OOE+00 O.OOE+00 1.82E+03 Sr-91 4.72E+01 O.OOE+00 1.91E+00 O.OOE+00 O.OOE+00 O.OOE+00 2.25E+02 Sr-92 1.79E+01 O.OOE+00 7.74E-01 O.OOE+00 O.OOE+00 O.OOE+00 3.55E+02 Y-90 8.01E-02 O.OOE+00 2.15E-03 O.OOE+00 O.OOE+00 O.OOE+00 8.49E+02 Y-91M 7.56E-04 O.OOE+00 2.93E-05 O.OOE+00 O.OOE+00 O.OOE+00 2.22E-03 Y-91 1.17E+00 O.OOE+00 3.14E-02 O.OOE+00 O.OOE+00 O.OOE+00 6.46E+02 Y-92 7.03E-03 O.OOE+00 2.06E-04 O.OOE+00 O.OOE+00 O.OOE+00 1.23E+02 Y-93 2.23E-02 O.OOE+00 6.16E-04 O.OOE+00 O.OOE+00 O.OOE+00 7.07E+02 Zr-95 2.53E-01 8.1 IE-02 5.49E-02 O.OOE+00 1.27E-01 O.OOE+00 2.57E+02 Zr-97 1.40E-02 2.82E-03 1.29E-03 O.OOE+00 4.26E-03 O.OOE+00 8.74E+02 Nb-95 5.18E-02 2.88E-02 1.55E-02 O.OOE+00 2.85E-02 O.OOE+00 1.75E+02 Mo-99 O.OOE+00 3.59E+01 6.82E+00 0.OOE+00 8.12E+01 O.OOE+00 8.31E+O1 Tc-99M 2.06E-03 5.81E-03 7.40E-02 O.OOE+00 8.82E-02 2.85E-03 3.44E+00 Tc-101 2.11E-03 3.05E-03 2.99E-02 O.OOE+00 5.48E-02 1.56E-03 9.15E-15 Ru-103 1.54E+00 O.OOE+00 6.63E-01 O.OOE+00 5.88E+00 O.OOE+00 1.80E+02 Ru-105 1.28E-01 O.OOE+00 5.06E-02 O.OOE+00 1.66E+00 O.OOE+00 7.84E+01 Ru-106 2.29E+01 O.OOE+00 2.90E+00 O.OOE+00 4.42E+01 O.OOE+00 1.48E+03 Ag-lIOM 1.33E+00 1.23E+00 7.32E-01 O.OOE+00 2.42E+00 O.OOE+00 5.03E+i02 Te-125M 2.23E+011 8.08E+00 2.99E+00 6.71E+00 9.07E+01 O.OOE+00 8.90E+01 Page 11.3-9

CY-BY-170-301 Revision 8 Table 3-1 (continued)

Site Specific Potable Water Dose Factors for Adult Age Group Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-127M 5.63E+01 2.01E+0I1 6.87E+00 1.44E+01 2.29E+02 0.OOE+00 1.89E+02 Te-127 9.15E-01 3.29E-01 1.98E-01 6.78E-01 3.73E+00 O.OOE+00 7.22E+01 Te-129M 9.57E+01 3.57E+01 1.51E+01 3.29E+01 3.99E+02 0.OOE+00 4.82E+02 Te-129 2.61E-01 9.82E-02 6.37E-02 2.01E-01 1.1OE+00 O.OOE+00 1.97E-01 Te-131M 1.44E+01 7.04E+00 5.87E+00 1.12E+01 7.13E+01 O.OOE+00 6.99E+02 Te-131 1.64E-01 6.85E-02 5.18E-02 1.35E-01 7.18E-01 0.OOE+00 2.32E-02 Te-132 2.1OE+O1 1.36E+01 1.27E+01 1.50E+01 1.31E+02 0.OOE+00 6.42E+02 1-130 6.29E+00 1.86E+01 7.32E+00 1.57E+03 2.90E+O1 O.OOE+00 1.60E+01 1-131 3.46E+01 4.95E+01 2.84E+01 1.62E+04 8.49E+01 O.OOE+00 1.31E+01 1-132 1.69E+00 4.52E+00 1.58E+00 1.58E+02 7.20E+00 O.OOE+00 8.49E-01 1-133 1.18E+01 2.06E+01 6.27E+00 3.02E+03 3.59E+01 O.00E+00 1.85E+01 1-134 8.82E-01 2.40E+00 8.57E-01 4.15E+O1 3.81EE+00' O.OOE+00 2.09E-03 1-135 3.69E+00 9.65E1+00 3.56E+00 6.37E+02 1.55E+01 O.OOE+00 1.09E+01 Cs-134 5.18E+02 1.23E+03 1.OIE+03 O.OOE+00 3.99E+02 1.32E+02 2.16E+01 Cs-136 5.42E+0O1 2.14E+02 1.54E+02 0.OOE+00 1.19E+02 1.63E+01 2.43E+01 Cs-137 6.63E+02 9.07E+02 5.94E+02 O.OOE+00 3.08E+02 1.02E+02 1.76E+01 Cs-138 4.59E-01 9.07E-01 4.49E-01 0.OOE+00 6.67E-01 6.58E-02 3.87E-06 Ba-139 8.07E-01 5.75E-04 2.36E-02 O.OOE+00 5.38E-04 3.26E-04 1.43E+00 Ba-140 1.69E+02 2.12E-01 1.I1E+01 0.OOE+00 7.22E-02 1.22E-01 3.48E+02 Ba-141 3.92E-01 2.96E-04 1.32E-02 O.OOE+00 2.75E-04 1.68E-04 1.85E-10 Ba-142 1.77E-01 1.82E-04 1.12E-02 O.OOE+00 1.54E-04 1.03E-04 2.50E-19 La-140 2.08E-02 1.05E-02 2.77E-03 O.OOE+00 O.OOE+00 O.OOE+00 7.70E+02 La-142 1.07E-03 4.84E-04 1.21E-04 0.OOE+00 O.OOE+00 0.OOE+00 3.54E+00 Ce-141 7.79E-02 5.27E-02 5.98E-03 0.OOE+00 2.45E-02 O.OOE+00 2.01E E+02 Ce-143 1.37E-02 1.02E+01 1.12E-03 O.OOE+00 4.47E-03 O.OOE+00 3.79E+02 Ce-144 4.06E+00 1.70E+00 2.18E-01 O.OOE+00 1.O1E+00 0.00E+00 1.37E+03 Pr-143 7.66E-02 3.07E-02 3.79E-03 0.OOE+00 1.77E-02 0.OOE+00 3.35E+02 Pr-144 2.50E-04 1.04E-04 1.27E-05 O.OOE+00 5.87E-05 O.OOE+00 3.60E-1 1 Nd-147 5.23E-02 6.05E-02 3.62E-03 0.00E+0O 3.54E-02 0.OOE+00 2.90E+02 W-187 8.57E-01 7.17E-01 2.50E-01 0.OOE+00 0.OOE+00 O.OOE+00 2.35E+02 Np-239 9.90E-03 9.74E-04 5.37E-04 O.OOE+00 3.04E-03 O.OOE+00 2.OOE+02 Notes:

1)

Units are mrem/hr per aCi/ml.

Page 11.3-10

CY-BY-170-301 I Revision 8 Table 3-2 Site Specific Potable Water Dose Factors for Teen Age Group Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI H-3 O.OOE+00 3.51E-01 3.51E-01 3.51E-01 3.51E-01 3.51E-01 3.51E-01 Na-24 1.34E+01 1.34E+01 1.34E+O1 1.34E+0O1 1.34E+01 1.34E+01 1.34E+01 Cr-51 O.OOE+00 O.OOE+00 2.09E-02 1.16E-02 4.59E-03 2.99E-02 3.52E+00 Mn-54 O.OOE+00 3.43E+01 6.80E+00 O.OOE+00 1.02E+01 O.OOE+00 7.03E+O1 Mn-56 O.OOE+00 9.19E-01 1.63E-01 O.OOE+00 1.16E+00 O.OOE+00 6.05E+01 Fe-55 2.20E+01 1.56E+01 3.63E+00 0.00E+00 O.OOE+00 9.88E+00 6.74E+00 Fe-59 3.41E+01 7.97E+01 3.08E+01 O.OOE+00 O.OOE+00 2.51E+O1 1.88E+02 Co-58 O.OOE+00 5.65E+00 1.30E+01 O.OOE+00 O.OOE+00 O.OOE+00 7.79E+01 Co-60 O.OOE+00 1.63E+01 3.68E+01 O.OOE+00 O.OOE+00 O.OOE+00 2.13E+02 Ni-63 1.03E+03 7.27E+01 3.49E+01 O.OOE+00 O.OOE+00 O.OOE+00 1.16E+O1 Ni-65 4.35E+00 5.56E-01 2.53E-01 O.OOE+00 O.OOE+00 O.OOE+00 3.02E+01 Cu-64 O.OOE+00 6.69E-01 3.15E-01 O.OOE+00 1.69E+00 O.OOE+00 5.19E+01 Zn-65 3.35E+O1 1.16E+02 5.42E+01 O.OOE+00 7.44E+01 O.OOE+00 4.92E+01 Zn-69 8.55E-02 1.63E-01 1.14E-02 O.OOE+00 1.06E-01 O.OOE+00 3.OOE-01 Br-83 O.OOE+00 O.OOE+00 3.34E-01 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-84 O.OOE+00 O.OOE+00 4.20E-01 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-85 O.OOE+00 O.OOE+00 1.77E-02 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-86 O.OOE+00 1.73E+02 8.14E+01 O.OOE+00 O.OOE+00 O.OOE+00 2.56E+O1 Rb-88 O.OOE+00 4.95E-01 2.64E-01 O.OOE+00 O.OOE+00 O.OOE+00 4.24E-08 Rb-89 O.OOE+00 3.20E-01 2.26E-01 O.OOE+00 O.OOE+00 O.OOE+00 4.90E-10 Sr-89 2.56E+03 O.OOE+00 7.33E+01 O.OOE+00 O.OOE+00 O.OOE+00 3.05E+02 Sr-90 5.93E+04 0.OOE+00 1.19E+03 O.OOE+00 O.OOE+00 O.OOE+00 1.35E+03 Sr-91 4.69E+01 O.OOE+00 1.87E+00 O.OOE+00 O.OOE+00 O.OOE+00 2.13E+02 Sr-92 1.77E+01 O.OOE+00 7.56E-01 O.OOE+00 O.OOE+00 O.OOE+00 4.52E+02 Y-90 7.97E-02 O.OOE+00 2.15E-03 O.OOE+00 O.OOE+00 O.OOE+00 6.57E+02 Y-91M 7.50E-04 O.OOE+00 2.87E-05 O.OOE+00 O.OOE+00 O.OOE+00 3.54E-02 Y-91 1.17E+00 O.OOE+00 3.13E-02 O.OOE+00 O.OOE+00 O.OOE+00 4.79E+02 Y-92 7.03E-03 O.OOE+00 2.03E-04 O.OOE+00 O.OOE+00 O.OOE+00 1.93E+02 Y-93 2.23E-02 O.OOE+00 6.10E-04 O.OOE+00 O.OOE+00 O.OOE+00 6.80E+02 Zr-95 2.40E-01 7.56E-02 5.20E-02 O.OOE+00 I.IIE-01 O.OOE+00 1.74E+02 Zr-97 1.38E-02 2.73E-03 1.26E-03 O.OOE+00 4.13E-03 O.OOE+00 7.38E+02 Nb-95 4.78E-02 2.65E-02 1.46E-02 O.OOE+00 2.57E-02 O.OOE+00 1.13E+02 Mo-99 O.OOE+00 3.5 1E+O1 6.69E+00 O.OOE+00 8.02E+01 O.OOE+00 6.28E+01 Tc-99M 1.93E-03 5.38E-03 6.98E-02 O.OOE+00 8.02E-02 2.99E-03 3.53E+00 Tc-101 2.09E-03 2.98E-03 2.92E-02 O.OOE+00 5.38E-02 1.81E-03 5.09E-10 Ru-103 1.48E+00 O.OOE+00 6.34E-01 O.OOE+00 5.23E+00 O.OOE+00 1.24E+02 Ru-105 1.27E-01 O.OOE+00 4.92E-02 O.OOE+00 1.60E+00 O.OOE+00 1.02E+02 Ru-106 2.28E+01 O.OOE+O0 2.87E+00 O.OOE+00 4.40E+01 O.OOE+00 1.09E+03 Ag-ll0M 1.19E+00 1.13E+00 6.86E-01 O.OOE+00 2.15E+00 O.OOE+00 3.17E+02 Te-125M 2.23E+01 8.02E+00 2.98E1+00 6.22E+00 O.OOE+00 O.OOE+00 6.57E+01 Page 11.3-11

CY-BY-1 70-301 Revision 8 Table 3-2 (continued)

Site Specific Potable Water Dose Factors for Teen Age Group Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-127M 5.62E+01 1.99E+01 6.69E+00 1.34E+01 2.28E+02 0.OOE+00 1.40E+02 Te-127 9.19E-01 3.26E-01 1.98E-01 6.34E-01 3.72E+00 O.OOE+00 7.09E+01 Te-129M 9.48E+01 3.52E+01 1.50E+01 3.06E+01 3.97E+02 0.OOE+00 3.56E+02 Te-129 2.60E-01 9.71E-02 6.34E-02 1.86E-01 1.09E+00 O.OOE+00 1.42E+00 Te-131M 1.42E+01 6.80E+00 5.67E+00 1.02E+01 7.09E+01 O.OOE+00 5.46E+02 Te-131 1.62E-01 6.69E-02 5.07E-02 1.25E-01 7.09E-01 0.OOE+00 1.33E-02 Te-132 2.03E+01 1.28E+01 1.21E+01 1.35E+01 1.23E+02 0.OOE+00 4.07E+02 1-130 5.99E+00 1.73E+01 6.92E+00 1.41E+03 2.67E+01 O.OOE+00 1.33E+01 1-131 3.40E+01 4.76E+01 2.56E+01 1.39E+04 8.20E+01 O.OOE+00 9.42E+00 1-132 1.62E+00 4.24E+00 1.52E+00 1.43E+02 6.69E+00 0.OOE+00 1.85E+00 1-133 1.17E+01 1.98E+01 6.05E+00 2.77E+03 3.48E+01 0.OOE+00 1.50E+01 1-134 8.49E-01 2.25E+00 8.08E-01 3.75E+01 3.55E+00 O.OOE+00 2.97E-02 1-135 3.55E+00 9.13E+00 3.38E+00 5.87E+02 1.44E+01 O.OOE+00 1.01E+01 Cs-134 4.87E+02 1.15E+03 5.31E+02 O.OOE+00 3.64E+02 1.39E+02 1.42E+01 Cs-136 4.99E+01 1.97E+02 1.32E+02 O.OOE+00 1.07E+02 1.69E+01 1.58E+01 Cs-137 6.51E E+02 8.66E+02 3.02E+02 O.OOE+00 2.95E+02 1.15E+02 1.23E+01 Cs-138 4.51E-01 8.66E-01 4.33E-01 0.OOE+00 6.40E-01 7.44E-02 3.93E-04 Ba-139 8.08E-01 5.69E-04 2.35E-02 O.OOE+00 5.36E-04 3.92E-04 7.21E+00 Ba-140 1.65E+02 2.02E-01 1.06E+01 O.OOE+00 6.86E-02 1.36E-01 2.55E+02 Ba-141 3.90E-01 2.91E-04 1.30E-02 0.OOE+00 2.70E-04 1.99E-04 8.31E-07 Ba-142 1.74E-01 1.74E-04 1.07E-02 0.OOE+00 1.47E-04 1.16E-04 5.34E-13 La-140 2.02E-02 9.94E-03 2.65E-03 0.OOE+00 O.OOE+00 O.OOE+00 5.71E+02 La-142 1.04E-03 4.62E-04 1.15E-04 0.OOE+00 O.OOE+0O 0.OOE+00 1.41E+01 Ce-141 7.73E-02 5.16E-02 5.93E-03 O.OOE+00 2.43E-02 O.OOE+00 1.48E+02 Ce-143 1.37E-02 9.94E+00 1.11E-03 0.OOE+00 4.46E-03 0.OOE+00 2.99E+02 Ce-144 4.05E+00 1.67E+00 2.17E-01 0.OOE+00 1.OOE+00 0.OOE+00 1.02E+03 Pr-143 7.62E-02 3.04E-02 3.79E-03 0.OOE+00 1.77E-02 0.OOE+00 2.51E+02 Pr-144 2.50E-04 1.02E-04 1.27E-05 0.OOE+00 5.87E-05 0.OOE+00 2.76E-07 Nd-147 5.45E-02 5.93E-02 3.55E-03 0.OOE+00 3.48E-02 O.OOE+00 2.14E+02 W-187 8.49E-01 6.92E-01 2.42E-01 0.OOE+00 O.OOE+00 0.OOE+00 1.87E+02 Np-239 1.02E-02 9.65E-04 5.36E-04 0.OOE+00 3.03E-03 O.OOE+00 1.55E+02 Notes:

1)

Units are mrem/hr per tCi/ml.

Page 11.3-12

CY-BY-1 70-3011 Revision 8 Table 3-3 Site Specific Potable Water Dose Factors for Child Age Group Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI H-3 0.00E+00 6.74E-01 6.74E-01 6.74E-01 6.74E-01 6.74E-01 6.74E-01 Na-24 3.37E+01 3.37E+01 3.37E+01 3.37E1+01 3.37E+01 3.37E+01 3.37E+01 Cr-51 0.00E+00 O.OOE+00 5.17E-02 2.87E-02 7.85E-03 5.24E-02 2.74E+00 Mn-54 O.OOE+00 6.22E+01 1.66E+01 O.OOE+00 1.74E+01 O.OOE+00 5.22E+0O1 Mn-56 O.OOE+00 1.94E+00 4.38E-01 O.OOE+00 2.35E+00 O.OOE+00 2.81EE+02 Fe-55 6.69E+01 3.55E+01 1.1OE+O1 O.OOE+00 O.OOE+00 2.01E+0I1 6.57E+00 Fe-59 9.59E+01 1.55E+02 7.73E+01 O.OOE+00 O.OOE+00 4.50E+01 1.62E+02 Co-58 O.OOE+00 1.05E+01 3.20E+01 O.OOE+00 O.OOE+00 O.OOE+00 6.1OE+O1 Co-60 O.OOE+00 3.08E+01 9.07E+O1 O.OOE+00 O.OOE+00 O.OOE+00 1.70E+02 Ni-63 3.13E+03 1.67E+02 1.06E+02 O.OOE+00 O.OOE+00 O.OOE+00 1.13E+01 Ni-65 1.29E+01 1.22E+00 7.09E-01 O.OOE+00 O.OOE+00 O.OOE+00 1.49E+02 Cu-64 O.OOE+00 1.42E+00 8.60E-01 O.OOE+00 3.44E+00 O.OOE+00 6.69E+01 Zn-65 7.97E+01 2.12E+02 1.32E+02 O.OOE+00 1.34E+02 O.OOE+00 3.73E+01 Zn-69 2.55E-01 3.68E-01 3.40E-02 O.OOE+00 2.23E-01 O.OOE+00 2.32E+01 Br-83 O.OOE+00 O.OOE+00 9.94E-01 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-84 O.OOE+00 O.OOE+00 1.15E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-85 O.OOE+00 O.OOE+00 5.30E-02 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-86 O.OOE+00 3.90E+02 2.40E+02 O.OOE+00 O.OOE+00 O.OOE+00 2.5 1E+O1 Rb-88 O.OOE+00 1.10E+00 7.67E-01 O.OOE+00 O.OOE+00 O.OOE+00 5.42E-02 Rb-89 0.00E+00 6.80E-01 6.05E-01 O.OOE+00 O.OOE+00 O.OOE+00 5.93E-03 Sr-89 7.67E+03 O.OOE+00 2.19E+02 O.OOE+00 O.OOE+00 O.OOE+00 2.97E+02 Sr-90 1.49E+05 O.OOE+00 2.99E+03 O.OOE+00 O.OOE+00 O.OOE+00 1.33E+03 Sr-91 1.40E+02 O.OOE+00 5.27E+00 O.OOE+00 O.OOE+00 O.OOE+00 3.08E+02 Sr-92 5.25E+O1 O.OOE+00 2.1OE+00 O.OOE+00 O.OOE+00 O.OOE+00 9.94E+02 Y-90 2.39E-01 O.OOE+00 6.40E-03 O.OOE+00 O.OOE+00 O.OOE+00 6.80E+02 Y-91M 2.22E-03 O.OOE+00 8.08E-05 O.OOE+00 O.OOE+00 O.OOE+00 4.35E+00 Y-91 3.50E+00 O.OOE+00 9.36E-02 O.OOE+00 O.OOE+00 O.OOE+00 4.66E+02 Y-92 2.09E-02 O.OOE+00 5.99E-04 O.OOE+00 O.OOE+00 O.OOE+00 6.05E+02 Y-93 6.63E-02 O.OOE+00 1.82E-03 O.OOE+00 O.OOE+00 O.OOE+00 9.88E+02 Zr-95 6.74E-01 1.48E-01 1.32E-01 O.OOE+00 2.12E-01 O.OOE+00 1.55E+02 Zr-97 4.06E-02 5.87E-03 3.47E-03 O.OOE+00 8.43E-03 O.OOE+00 8.90E+02 Nb-95 1.31E-01 5.09E-02 3.64E-02 O.OOE+00 4.78E-02 O.OOE+00 9.42E+01 Mo-99 O.OOE+00 7.73E+01 1.91E+O1 O.OOE+00 1.65E+02 O.OOE+00 6.40E+01 Tc-99M 5.37E-03 1.05E-02 1.74E-01 O.OOE+00 1.53E-01 5.34E-03 5.99E+00 Tc-101 6.22E-03 6.51E-03 8.26E-02 O.OOE+00 1.11E-01 3.44E-03 2.07E-02 Ru-103 4.25E+00 O.OOE+00 1.63E+00 O.OOE+00 1.07E+01 O.OOE+00 1. 1OE+02 Ru-105 3.75E-01 O.OOE+00 1.36E-01 O.OOE+00 3.30E+00 O.OOE+00 2.45E+02 Ru-106 6.80E+01 O.OOE+00 8.49E+00 O.OOE+00 9.19E+01 O.OOE+00 1.06E+03 Ag-lIOM 3.13E+00 2.12E+00 1.69E+00 0.00E+00 3.94E+00 O.OOE+00 2.52E+02 Te-125M 6.63E+01 1.80E+01 8.84E+00 1.86E+01 O.OOE+00 O.OOE+00 6.40E+01 Page 11.3-13

CY-BY-170-301 Revision 8 Table 3-3 (continued)

Site Specific Potable Water Dose Factors for Child Age Group Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-127M 1.68E+02 4.52E+01 1.99E+01 4.02E+01 4.79E+02 O.OOE+00 1.36E+02 Te-127 2.74E+00 7.38E-01 5.87E-01 1.90E+00 7.79E+00 O.OOE+00 1.07E+02 Te-129M 2.83E+02 7.91E+-i01 4.40E+O1 9.13E+01 8.31E E+02 O.OOE+00 3.45E+02 Te-129 7.79E-01 2.17E-01 1.85E-01 5.56E-01 2.28E+00 O.OOE+00 4.85E+I01 Te-131M 4.19E+01 1.45E+01 1.54E+01 2.98E+01 1.40E+02 O.OOE+00 5.87E+02 Te-131 4.83E-01 1.47E-01 1.44E-01 3.69E-01 1.46E+00 0.OOE+00 2.53E+00 Te-132 5.87E+01 2.60E+01 3.14E+01 3.78E+01 2.41E+02 O.OOE+00 2.62E+02 1-130 1.70E+01 3.43E+01 1.77E+01 3.78E+03 5.13E+01 0.OOE+00 1.60E+01 1-131 1.OOE+02 1.O1E+02 5.72E+01 3.33E+04 1.65E+02 0.OOE+00 8.95E+00 1-132 4.65E+00 8.55E+00 3.93E+00 3.97E+02 1.31E+01 O.OOE+00 1.OIE+01 1-133 3.44E+01 4.26E+01 1.61E+01 7.91E+03 7.09E+01 O.OOE+00 1.72E+01 1-134 2.44E+00 4.52E+00 2.08E+00 1.04E+02 6.92E+00 O.OOE+00 3.OOE+00 1-135 1.02E+01 1.83E+01 8.66E+00 1.62E+03 2.81E+01 O.OOE+00 1.40E+01 Cs-134 1.36E+03 2.23E+03 4.71E+02 O.OOE+00 6.92E+02 2.48E+02 1.20E+01 Cs-136 1.37E+02 3.76E+02 2.43E+02 O.OOE+00 2.OOE+02 2.98E+01 1.32E+01 Cs-137 1.90E+03 1.82E+03 2.69E+02 O.OOE+00 5.93E+02 2.13E+02 1.14E+01 Cs-138 1.33E+00 1.84E+00 1.17E+00 O.OOE+00 1.30E+00 1.40E-01 8.49E-01 Ba-139 2.41E E+00 1.28E-03 6.98E-02 0.OOE+00 1.12E-03 7.56E-04 1.39E+02 Ba-140 4.83E+02 4.23E-01 2.82E+01 0.OOE+00 1.38E-01 2.52E-01 2.45E+02 Ba-141 1.16E+00 6.51E-04 3.78E-02 O.OOE+00 5.63E-04 3.83E-03 6.63E-01 Ba-142 5.08E-01 3.66E-04 2.84E-02 0.OOE+00 2.96E-04 2.15E-04 6.63E-03 La-140 5.87E-02 2.05E-02 6.92E-03 0.OOE+00 O.OOE+00 O.OOE+00 5.72E+02 La-142 3.05E-03 9.71E-04 3.04E-04 0.OOE+00 O.OOE+00 0.OOE+00 1.92E+02 Ce-141 2.31E-01 1.15E-01 1.71E-02 O.OOE+00 5.05E-02 O.OOE+00 1.44E+02 Ce-143 4.06E-02 2.20E+01 3.19E-03 0.OOE+00 9.24E-03 O.OOE+00 3.23E+02 Ce-144 1.21E+01 3.79E+00 6.45E-01 O.OOE+00 2.1OE+00 O.OOE+00 9.88E+02 Pr-143 2.28E-01 6.86E-02 1.13E-02 O.OOE+00 3.72E-02 0.OOE+00 2.47E+02 Pr-144 7.50E-04 2.32E-04 3.77E-05 O.OOE+00 1.23E-04 O.OOE+00 4.99E-01 Nd-147 1.62E-01 1.31E-01 1.02E-02 O.OOE+00 7.21E-02 O.OOE+00 2.08E+02 W-187 2.49E+00 1.48E+00 6.63E-01 O.OOE+00 0.OOE+00 O.OOE+00 2.08E+02 Np-239 3.05E-02 2.19E-03 1.54E-03 0.00E+00 6.34E-03 O.OOE+00 1.62E+02 Notes:

1)

Units are mrem/hr per jiCi/mI.

Page 11.3-14

CY-BY-170-301 1 Revision 8 Table 3-4 Site Specific Potable Water Dose Factors for Infant Age Group Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI H-3 O.OOE+00 6.62E-01 6.62E-01 6.62E-01 6.62E-01 6.62E-01 6.62E-01 Na-24 3.80E+01 3.80E+O1 3.80E+01 3.80E+01 3.80E+01 3.80E+01 3.80E+O1 Cr-51 O.OOE+00 O.OOE+00 5.30E-02 3.46E-02 7.56E-03 6.73E-02 1.55E+00 Mn-54 O.OOE+00 7.49E+01 1.70E+01 O.OOE+00 1.66E+01 0.00E+00 2.75E+01 Mn-56 O.OOE+00 3.08E+00 5.30E-01 O.OOE+00 2.64E+00 O.OOE+00 2.80E+02 Fe-55 5.23E+01 3.38E+01 9.03E+00 O.OOE+00 O.OOE+00 1.65E+01 4.29E+00 Fe-59 1.16E+02 2.02E+02 7.98E+01 O.OOE+00 O.OOE+00 5.98E+O1 9.67E+01 Co-58 O.OOE+00 1.35E+01 3.38E+01 O.OOE+00 O.OOE+00 O.OOE+00 3.37E+01 Co-60 0.00E+00 4.06E+01 9.59E+01 O.OOE+00 O.OOE+00 O.OOE+00 9.67E+01 Ni-63 2.39E+03 1.47E+02 8.28E+01 O.OOE+00 O.OOE+00 O.OOE+00 7.34E+00 Ni-65 1.77E+01 2.OOE+00 9.1OE-01 O.OOE+00 O.OOE+00 O.OOE+00 1.52E+02 Cu-64 0.00E+00 2.29E+00 1.06E+00 O.OOE+00 3.87E+00 O.OOE+00 4.70E+01 Zn-65 6.92E+01 2.37E+02 1.09E+02 O.OOE+00 1.15E+02 O.OOE+00 2.01E+02 Zn-69 3.51E-01 6.32E-01 4.70E-021 O.OOE+00 2.63E-01 O.OOE+00 5.15E+01 Br-83 O.OOE+00 O.OOE+00 1.37E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-84 O.OOE+00 O.OOE+00 1.44E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-85 O.OOE+00 O.OOE+00 7.30E-02 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-86 O.OOE+00i 6.40E+02 3.16E+02 O.OOE+00 O.OOE+00 O.OOE+00 1.64E+01 Rb-88 O.OOE+00 1.87E+00 1.03E+001 O.OOE+00 O.OOE+00 O.OOE+00 1.82E+00 Rb-89 O.OOE+00 1.08E+00 7.41E-01 O.OOE+00 O.OOE+00 O.OOE+00 3.66E-01 Sr-89 9.44E+03 0.003E+00 2.71E+02 O.OOE+00 O.OOE+00 O.OOE+00 1.94E+02 Sr-90 1.06E+05 O.OOE+00 2.16E+03 O.OOE+00 O.OOE+00 O.OOE+00 8.69E+02 Sr-91 1.88E+02 0.00E+00 6.8 1E+00 O.OOE+00 O.OOE+00 O.OOE+00 2.23E+02 Sr-92 7.22E+01 O.OOE+00 2.68E+00 O.OOE+00 O.OOE+00 O.OOE+00 7.79E+02 Y-90 3.27E-01 O.OOE+00 8.77E-03 O.OOE+00 O.OOE+00 O.OOE+00 4.5 1E+02 Y-91M 3.05E-03 O.OOE+00 1.04E-04 O.OOE+00 O.OOE+00 0.00E+00 1.02E+01 Y-91 4.25E+00 O.OOE+00 1.13E-01 O.OOE+00 O.OOE+00 O.OOE+00 3.05E+02 Y-92 2.88E-02 O.OOE+00 8.09E-04 O.OOE+00 O.OOE+00 O.OOE+00 5.49E+02 Y-93 9.14E-02 O.OOE+00 2.49E-03 O.OOE+00 O.OOE+00 O.OOE+00 7.22E+02 Zr-95 7.75E-01 1.89E-01 1.34E-01 O.OOE+00 2.04E-01 O.OOE+00 9.41E+O1 Zr-97 5.57E-02 9.56E-03 4.36E-03 O.OOE+00 9.63E-03 O.OOE+00 6.09E+02 Nb-95 1.58E-01 6.51E-02 3.76E-02 O.OOE+00 4.66E-02 O.OOE+00 5.49E+01 Mo-99 O.OOE+00 1.28E+02 2.49E+01 O.OOE+00 1.91E+02 O.OOE+00 4.21E+O1 Tc-99M 7.22E-03 1.49E-02 1.92E-01 O.OOE+00 1.60E-01 7.79E-03 4.33E+00 Tc-101 8.54E-03 1.08E-02 1.06E-01 O.OOE+00 1.28E-01 5.87E-03 1.83E+00 Ru-103 5.57E+00 O.OOE+00 1.86E+00 O.OOE+00 1.16E+O1 O.OOE+00 6.77E+01 Ru-105 5.12E-01 O.OOE+0 1.72E-01 O.OOE+00 3.76E+00 O.OOE+00 2.04E+02 Ru-106 9.07E+01 O.OOE+00 1.13E+O1 O.OOE+00 1.07E+02 O.OOE+00 6.88E+02 Ag-ll0M 3.75E+00 2.73E+00 1.8 1E+00 O.OOE+00 3.91E+00 O.OOE+00 1.42E+02 Te-125M 8.77E+01 2.93E+01 1.19E+01 2.95E1+01 O.OOE+00 O.OOE+00 4.18E+O1 Page 11.3-15

CY-BY-170-301 Revision 8 Table 3-4 (continued)

Site Specific Potable Water Dose Factors for Infant Age Group Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-127M 2.20E+02 7.30E+01 2.66E+01 6.36E+01 5.42E+02 O.OOE+00 8.88E+I01 Te-127 3.76E+00 1.26E+00 8.09E-01 3.06E+00 9.18E+00 0.OOE+00 7.90E+01 Te-129M 3.76E+02 1.29E+02 5.79E+I01 1.44E+02 9.41E+02 O.OOE+00 2.25E+02 Te-129 1.07E+00 3.68E-01 2.49E-01 8.95E-01 2.66E+00 0.OOE+00 8.54E+01 Te-131M 5.72E+O1 2.30E+01 1.90E+01 4.66E+01 1.58E+02 0.OOE+00 3.87E+02 Te-131 6.62E-01 2.45E-01 1.86E-01 5.91E-01 1.69E+00 0.OOE+00 2.67E+01 Te-132 7.82E+01 3.87E+01 3.62E+01 5.72E+01 2.42E+02 0.OOE+00 1.43E+02 1-130 2.26E+01 4.97E+01 1.99E+01 5.57E+03 5.45E+01 O.OOE+00 1.06E+01 1-131 1.35E+02 1.59E+02 7.OOE+01 5.23E+04 1.86E+02 0.OOE+00 5.68E+00 1-132 6.24E+00 1.27E+01 4.51E+00 5.94E+02 1.41E+01 O.OOE+00 1.03E+01 1-133 4.70E+01 6.85E+01 2.01E+01 1.25E+04 8.05E+01 O.OOE+00 1.16E+01 1-134 3.27E+00 6.70E+00 2.38E+00 1.56E+02 7.49E+00 O.OOE+00 6.92E+00 1-135 1.37E+01 2.72E+01 9.93E+00 2.44E+03 3.04E+01 O.OOE+00 9.86E+00 Cs-134 1.42E+03 2.64E+03 2.67E+02 O.OOE+00 6.81E+02 2.79E+02 7.19E+00 Cs-136 1.73E+02 5.08E+02 1.90E+02 0.OOE+00 2.02E+02 4.14E+01 7.71E E+00 Cs-137 1.96E+03 2.30E+03 1.63E+02 0.OOE+00 6.17E+02 2.50E+02 7.19E+00 Cs-138 1.81E E+00 2.94E+00 1.43E+00 O.OOE+00 1.47E+00 2.29E-01 4.70E+00 Ba-139 3.31E E+00 2.20E-03 9.59E-02 O.OOE+00 1.32E-03 1.33E-03 2.1OE+02 Ba-140 6.43E+02 6.43E-01 3.31E-+i01 0.OOE+00 1.53E-01 3.95E-01 1.58E+02 Ba-141 1.60E+00 1.09E-03 5.04E-02 O.OOE+00 6.58E-04 6.66E-04 1.95E+011 Ba-142 6.92E-01 5.76E-04 3.41E-02 0.OOE+00 3.31E-04 3.48E-04 2.86E+00 La-140 7.94E-02 3.13E-02 8.05E-03 O.OOE+00 O.OOE+00 O.OOE+00 3.68E+02 La-142 4.14E-03 1.52E-03 3.64E-04 0.OOE+00 0.OOE+00 O.OOE+00 2.58E+02 Ce-141 2.96E-01 1.81E-01 2.13E-02 O.OOE+00 5.57E-02 O.OOE+00 9.33E+01 Ce-143 5.57E-02 3.69E+01 4.21E-03 0.OOE+00 1.08E-02 O.OOE+00 2.16E+02 Ce-144 1.12E+O1 4.59E+00 6.28E-01 0.OOE+00 1.85E+00 O.OOE+00 6.43E+02 Pr-143 3.06E-01 1.14E-01 1.52E-02 O.OOE+00 4.25E-02 O.OOE+00 1.61E+02 Pr-144 1.03E-03 3.99E-04 5.19E-05 O.OOE+00 1.44E-04 O.OOE+00 1.85E+01 Nd-147 2.08E-01 2.14E-01 1.31E-02 0.OOE+00 8.24E-02 0.OOE+00 1.35E+02 W-187 3.40E+00 2.36E+00 8.16E-01 0.OOE+00 O.OOE+00 0.OOE+00 1.39E+02 Np-239 4.18E-02 3.74E-03 2.11E-03 O.OOE+00 7.45E-03 0.OOE+00 1.08E+02 Notes:

1)

Units are mrem/hr per g.Ci/ml.

Page 11.3-16

CY-BY-170-301I Revision 8 Table 3-5 Site Specific Fish Ingestion Dose Factors for Adult Age Group Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI H-3 O.OOE+O0 1.29E-01 1.29E-01 1.29E-01 1.29E-01 1.29E-01 1.29E-01 Na-24 4.07E+02 4.07E+02 4.07E+02 4.07E+02 4.07E+02 4.07E+02 4.07E+02 Cr-51 O.OOE+O0 O.OOE+00 1.27E+00 7.61E-01 2.81E-0I 1.69E+00 3.20E+02 Mn-54 O.OOE+00 4.38E+03 8.35E+02 O.OOE+O0 1.30E+03 O.OOE+00 1.34E+04 Mn-56 O.00E+00 1.10E+02I 1.95E+01 O.OOE+00 1.40E+02 O.OOE+00 3.5 1E+03 Fe-55 6.58E+02 4.55E+02 1.06E+02 O.OOE+00 O.OOE+00 2.54E+02 2.61E+02 Fe-59 1.04E+03 2.44E+03 9.36E+02 O.OOE+00 O.OOE+00 6.82E+02 8.14E+03 Co-58 O.OOE+00 8.92E+OI 2.OOE+02 O.OOE+00 0.00E+00 O.OOE+00 1.81E+03 Co-60 O.OOE+0 2.56E+02 5.65E+02 O.OOE+00 O.OOE+00 O.OOE+00 4.8 1E+03 Ni-63 3.11E+04 2.16E+03 1.04E+03 O.OOE+00 O.OOE+00 O.OOE+00 4.50E+02 Ni-65 1.26E+02 1.64E+01 7.49E+00 O.OOE+00 O.OOE+00 O.OOE+00 4.17E+02 Cu-64 O.OOE+00 9.97E+00 4.68E+00 0.00E+00 2.5 1E+0O1 O.OOE+00 8.50E+02 Zn-65 2.32E+04 7.37E+04 3.33E+04 O.OOE+00 4.93E+04 O.OOE+00 4.64E+04 Zn-69 4.93E+01 9.43E+01 6.56E+00 O.OOE+00 6.13E+01 O.OOE+00 1.42E+01 Br-83 O.OOE+00 O.OOE+0O 4.04E+01 O.OOE+00 O.OOE+00 O.OOE+00 5.82E+O1 Br-84 O.OOE+00 O.OOE+00 5.24E+01 O.OOE+00 O.OOE+00 O.OOE+00 4.11E-04 Br-85 O.OOE+00 O.OOE+0 2.15E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.00E+0 Rb-86 O.OOE+00 1.01E+05 4.7 1E+04 O.OOE+00 O.OOE+00 O.OOE+00 1.99E+04 Rb-88 O.OOE+00 2.90E+02 1.54E+02 O.OOE+00 O.OOE+00 O.OOE+00 4.OOE-09 Rb-89 O.OOE+00 1.92E+02 1.35E+02 O.OOE+00 O.OOE+00 O.OOE+00 1.12E-I1 Sr-89 2.21E+04 O.OOE+00 6.35E+02 O.OOE+00 O.OOE+00 O.OOE+00 3.55E+03 Sr-90 6.26E+05 O.OOE+00 1.26E+04 O.OOE+00 O.OOE+00 O.OOE+00 1.57E+04 Sr-91 4.07E+02 O.OOE+00 1.64E+01 O.OOE+00 O.OOE+00 O.OOE+00 1.94E+03 Sr-92 1.54E+02 O.OOE+00 6.68E+00 O.OOE+00 O.OOE+0 O.OOE+00 3.06E+03 Y-90 5.76E-01 O.OOE+00 1.54E-02 O.OOE+0O O.OOE+0O O.OOE+00 6.1OE+03 Y-91M 5.44E-03 O.OOE+00 2.11 E-04 O.OOE+0 O.OOE+00 O.OOE+00 1.60E-02 Y-91 8.44E+00 O.OOE+00 2.26E-01 O.OOE+0 O.OOE+0O O.OOE+00 4.64E+03 Y-92 5.06E-02 O.OOE+00 1.48E-03 O.OOE+0 O.OOE+00 O.OOE+00 8.86E+02 Y-93 1.60E-01 0,00E+00 4.43E-03 O.OOE+0 O.OOE+00 O.OOE+00 5.09E+03 Zr-95 2.40E-01 7.70E-02 5.21E-02 O.OOE+0 1.21E-01 O.OOE+00 2.44E+02 Zr-97 1.33E-02 2.68E-03 1.22E-03 O.OOE+00 4.04E-03 O.OOE+00 8.30E+02 Nb-95 4.47E+02 2.48E+02 1.34E+02 O.OOE+00 2.46E+02 O.OOE+00 1.5 1E+06 Mo-99 O.OOE+00 1,03E+02 1.96E+O I O.OOE+00 2.34E+02 O.OOE+00 2.39E+02 Tc-99M 8.87E-03 2.51E-02 3.19E-01 O.OOE+00 3.81E-01 1.23E-02 1.48E+01 Tc-101 9.12E-03 1.31E-02 1.29E-01 O.OOE+00 2.37E-01 6.72E-03 3.95E-14 Ru-103 4.43E+00 O.OOE+00 1.91E+00 O.OOE+00 1.69E+01 O.OOE+00 5.17E+02 Ru-105 3.69E-01 O.OOE+00 1.46E-01 O.OOE+00 4.76E+00 O.OOE+00 2.26E+02 Ru-106 6.58E+01 O.OOE+00 8.33E+00 O.OOE+00 1.27E+02 O.OOE+00 4.26E+03 Ag-iIOM 8.81E-01 8.15E-01 4.84E-01 O.OOE+00 1.60E+00 O.OOE+00 3.33E+02 Te-125M 2.57E+03 9.30E+02 3.44E+02 7.72E+02 1.04E+04 O.OOE+00 1.02E+04 Page 11.3-17

CY-BY-170-301 Revision 8 Table 3-5 (continued)

Site Specific Fish Ingestion Dose Factors for Adult Age Group Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-127M 6.48E+03 2.32E+03 7.90E+02 1.66E+03 2.63E+04 O.OOE+00 2.17E+04 Te-127 1.05E+02 3.78E+01 2.28E+01 7.80E+01 4.29E+02 O.OOE+00 8.3 1E+03 Te-I 29M

1. 1OE+04 4.1 1E+03 1.74E+03 3.78E+03 4.60E+04 0.OOE+00 5.54E+04 Te-129 3.01E+O1 1.13E+01 7.33E+00 2.31E+01 1.26E+02 0.OOE+00 2.27E+01 Te-131M 1.66E+03 8.1OE+02 6.75E+02 1.28E+03 8.21E+03 O.OOE+00 8.04E+04 Te-131 1.89E+01 7.88E+00 5.96E+00 1.55E+01 8.26E+O1 0.003E+00 2.67E+00 Te-132 2.41E+03 1.56E+03 1.47E+03 1.72E+03 1.50E+04 0.OOE+00 7.38E+04 1-130 2.71E+01 8.01E+01 3.16E+O1 6.79E+03 1.25E+02 0.OOE+00 6.89E+01 1-131 1.49E+02 2.14E+02 1.22E+02 7.OOE+04 3.66E+02 O.OOE+00 5.64E+01 1-132 7.29E+00 1.95E+01 6.82E+00 6.82E+02 3.1 IE+0O1 O.OOE+00 3.66E+00 1-133 5.1OE+01 8.87E+01 2.70E+01 1.30E+04 1.55E+02 O.OOE+00 7.97E+01 1-134 3.81E+00 1.03E+01 3.70E+00 1.79E+02 1.64E+O1 O.OOE+00 9.01E-03 1-135 1.59E+01 4.17E+01 1.54E+01 2.75E+03 6.68E+01 O.OOE+00 4.70E+O1 Cs-134 2.98E+05 7.09E+05 5.79E+05 0.OOE+00 2.29E+05 7.61E+04 1.24E+04 Cs-136 3.12E+04 1.23E+05 8.86E+04 O.OOE+00 6.85E+04 9.38E+03 1.40E+04 Cs-137 3.82E+05 5.22E+05 3.42E+05 O.OOE+00 1.77E+05 5.89E+04 1.01E+04 Cs-138 2.64E+02 5.22E+02 2.59E+02 O.OOE+00 3.84E+02 3.79E+01 2.23E-03 Ba-139 9.29E-01 6.62E-04 2.72E-02 O.OOE+00 6.19E-04 3.75E-04 1.65E+00 Ba-140 1.94E+02 2.44E-01 1.27E+01 0.OOE+00 8.30E-02 1.40E-01 4.OOE+02 Ba-141 4.51E-01 3.41E-04 1.52E-02 0.OOE+00 3.17E-04 1.93E-04 2.13E-10 Ba-142 2.04E-01 2.10E-04 1.28E-02 0.OOE+00 1.77E-04 1.19E-04 2.87E-19 La-140 1.50E-01 7.54E-02 1.99E-02 0.OOE+00 0.OOE+00 0.OOE+00 5.54E+03 La-142 7.66E-03 3.48E-03 8.68E-04 O.OOE+00 O.OOE+00 0.OOE+00 2.54E+01 Ce-141 2.24E-02 1.52E-02 1.72E-03 O.OOE+00 7.04E-03 0.00E+00 5.79E+01 Ce-143 3.95E-03 2.92E+00 3.23E-04 O.OOE+00 1.29E-03 0.OOE+00 1.09E+02 Ce-144 1.17E+00 4.88E-01 6.27E-02 O.OOE+00 2.90E-01 O.OOE+00 3.95E+02 Pr-143 5.51E-01 2.21E-01 2.73E-02 0.OOE+00 1.27E-01 0.OOE+00 2.41E+03 Pr-144 1.80E-03 7.48E-04 9.16E-05 0.OOE+00 4.22E-04 0.OOE+00 2.59E-10 Nd-147 3.76E-01 4.35E-01 2.60E-02 O.OOE+00 2.54E-01 O.OOE+00 2.09E+03 W-187 2.96E+02 2.47E+02 8.65E+01 O.OOE+001 0.OOE+00 0.OOE+00 8.10E+04 Np-239 2.85E-02 2.80E-03 1.54E-03 O.OOE+00 8.74E-03 O.OOE+00 5.75E+02 Notes:
1)

Units are mremn/hr per.tCi/ml.

Page 11.3-18

CY-BY-170-301 I Revision 8 Table 3-6 Site Specific Fish Ingestion Dose Factors for Teen Age Group Nuclide Bone Liver T Body Thyroid Kidney Luna GI-LLI H-3 O.OOE+00 9.92E-02 9.92E-02 9.92E-02 9.92E-02 9.92E-02 9.92E-02 Na-24 4.20E+02 4.20E+02 4.20E+02 4.20E+02 4.20E+02 4.20E+02 4.20E+02 Cr-51 O.OOE+00 O.OOE+00 1.31E E+00 7.30E-01 2.88E-01 1.88E+00 2.21E E+02 Mn-54 O.OOE+00 4.30E+03 8.54E+02 O.OOE+00 1.28E+03 O.OOE+00 8.83E+03 Mn-56 O.OOE+00 1.15E+02 2.05E+01 O.OOE+00 1.46E+02 O.OOE+00 7.59E+03 Fe-55 6.89E+02 4.89E+02 1.14E+02 O.OOE+00 O.OOE+00 3.10E+02 2.12E+02 Fe-59 1.07E+03 2.50E+03 9.65E+02 O.OOE+00 O.OOE+00 7.88E+02 5.91E+03 Co-58 O.OOE+00 8.86E+01 2.04E+02 O.OOE+00 O.OOE+00 O.OOE+00 1.22E+03 Co-60 O.OOE+00 2.56E+02 5.77E+02 O.OOE+00 O.OOE+00 O.OOE+00 3.34E+03 Ni-63 3.23E+04 2.28E+03 1.09E+03 O.OOE+00 O.OOE+00 O.OOE+00 3.63E+02 Ni-65 1.37E+02 1.75E+01 7.95E+00 O.OOE+00 O.OOE+00 O.OOE+00 9.47E+02 Cu-64 O.OOE+00 1.05E+01 4.93E+001 O.OOE+00 2.65E+01 O.OOE+00 8.14E+02 Zn-65 2.1OE+04 7.30E+04 3.40E+04 O.OOE+00 4.67E+04 O.OOE+00 3.09E+04 Zn-69 5.36E+01 1.02E+02 7.15E+00 O.OOE+00 6.68E+01 O.OOE+00 1.88E+02 Br-83 O.OOE+00 O.OOE+00 4.40E+01 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-84 O.OOE+00 O.OOE+00 5.53E+01 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-85 O.OOE+00 O.OOE+00 2.34E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-86 O.OOE+00 1.09E+05 5.11E+04 O.OOE+00 O.OOE+00 O.OOE+00 1.61E+04 Rb-88 O.OOE+00 3.1 IE+02 1.66E+02 O.OOE+00 O.OOE+00 O.OOE+O0 2.66E-05 Rb-89 O.OOE+00 2.01E+02 1.42E+02 O.OOE+00 O.OOE+00 O.OOE+00 3.08E-07 Sr-89 2.41E+04 O.OOE+00 6.89E+02 O.OOE+00 O.OOE+00 O.OOE+00 2.87E+03 Sr-90 5.58E+05 O.OOE+00 1. 12E+04 O.OOE+00 O.OOE+00 O.OOE+00 1.27E+04 Sr-91 4.42E+02 O.OOE+00 1.76E+01 O.OOE+00 O.OOE+00 O.OOE+00 2.OOE+03 Sr-92 1.67E+02 O.OOE+00 7.11E+00 O.OOE+00 O.OOE+00 O.OOE+00 4.25E+03 Y-90 6.25E-01 O.OOE+00 1.68E-02 O.OOE+00 O.OOE+00 O.OOE+00 5.15E+03 Y-91M 5.88E-03 O.OOE+00 2.25E-04 O.OOE+00 O.OOE+00 O.OOE+00 2.78E-01 Y-91 9.17E+00 O.OOE+00 2.46E-01 O.OOE+00 O.OOE+00 O.OOE+00 3.76E+03 Y-92 5.52E-02 O.OOE+00 1.60E-03 O.OOE+00 O.OOE+00 O.OOE+00 1.51E+03 Y-93 1.75E-01 O.OOE+00 4.79E-03 O.OOE+00 O.OOE+00 O.OOE+00 5.34E+03 Zr-95 2.48E-01 7.82E-02 5.38E-02 O.OOE+00 1.15E-01 O.OOE+00 1.81E E+02 Zr-97 1.43E-02 2.82E-03 1.30E-03 O.OOE+00 4.28E-03 O.OOE+00 7.64E+02 Nb-95 4.50E+02 2.50E+02 1.37E+02 O.OOE+00 2.42E+02 O.OOE+00 1.07E+06 Mo-99 O.OOE+00 1.1OE+02 2.1OE+O1 O.OOE+00 2.52E+02 O.OOE+00 1.97E+02 Tc-99M 9.08E-03 2.53E-02 3.28E-01 O.OOE+00 3.78E-01 1.4 1E-02 1.66E+01 Tc-101 9.85E-03 1.40E-02 1.38E-01 O.OOE+00 2.53E-01 8.54E-03 2.39E-09 Ru-103 4.65E+00 O.OOE+00 1.99E+00 O.OOE+00 1.64E+O1 O.OOE+00 3.89E+02 Ru-105 3.98E-01 O.OOE+00 1.54E-01 O.OOE+00 5.02E+00 O.OOE+00 3.21E+02 Ru-106 7.15E+01 O.OOE+00 9.01E+00 O.OOE+00 1.38E+02 O.OOE+00 3.43E+03 Ag-IIOM 8.60E-01 8.14E-01 4.95E-01 O.OOE+00 1.55E+00 O.OOE+00 2.29E+02 Te-125M 2.79E+03 1.01E+03 3.74E+02 7.81E+02 O.OOE+00 O.OOE+00 8.24E+03 Page 11.3-19

CY-BY-170-301 I Revision 8 Table 3-6 (continued)

Site Specific Fish Ingestion Dose Factors for Teen Age Group Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-127M 7.06E+03 2.50E+03 8.39E+02 1.68E+03 2.86E+04 O.OOE+00 1.76E+04 Te-127 1.15E+02 4.09E+01 2.48E+01 7.95E+01 4.67E+02 O.OOE+00 8.90E+03 Te-129M 1.19E+04 4.41E1+03 1.88E+03 3.84E+03 4.98E+04 0.OOE+00 4.47E+04 Te-129 3.27E+O1 1.22E+01 7.95E+00 2.33E+01 1.37E+02 0.OOE+00 1.79E+02 Te-131M 1.78E+03 8.54E+02 7.12E+02 1.28E+03 8.90E+03 0.OOE+00 6.85E+04 Te-131 2.04E+01 8.39E+00 6.36E+00 1.57E+01 8.90E+01 0.OOE+00 1.67E+00 Te-132 2.55E+03 1.61E+03 1.52E+03 1.70E+03 1.55E+04 0.OOE+00 5.11E+04 1-130 2.82E+01 8.15E+01 3.26E+O1 6.65E+03 1.26E+02 O.OOE+00 6.27E+01 1-131 1.60E+02 2.24E+02 1.20E+02 6.54E+04 3.86E+02 O.OOE+00 4.43E+01 1-132 7.63E+00 2.OOE+01 7.17E+00 6.73E+02 3.15E+01 0.OOE+00 8.70E+00 1-133 5.50E+01 9.33E+01 2.85E+01 1.30E+04 1.64E+02 0.OOE+00 7.06E+01 1-134 3.99E+00 1.06E+01 3.80E+00 1.76E+02 1.67E+01 0.OOE+00 1.40E-01 1-135 1.67E+01 4.30E+01 1.59E+01 2.76E+03 6.79E+01 0.OOE+00 4.76E+01 Cs-134 3.05E+05 7.19E+05 3.33E+05 0.OOE+00 2.28E+05 8.72E+04 8.94E+03 Cs-136 3.13E+04 1.23E+05 8.28E+04 O.OOE+00 6.71E+04 1.06E+04 9.92E+03 Cs-137 4.09E+05 5.44E+05 1.89E+05 0.OOE+00 1.85E+05 7.19E+04 7.73E+03 Cs-138 2.83E+02 5.44E+02 2.72E+02 O.OOE+00 4.01E+02 4.67E+01 2.47E-01 Ba-139 1.01E+00 7.14E-04 2.95E-02 0.OOE+00 6.73E-04 4.92E-04 9.05E+00 Ba-140 2.07E+02 2.54E-01 1.34E+01 O.OOE+00 8.61E-02 1.71E-01 3.20E+02 Ba-141 4.90E-01 3.66E-04 1.63E-02 0.OOE+00 3.39E-04 2.50E-04 1.04E-06 Ba-142 2.18E-01I 2.18E-04 1.34E-02 O.OOE+00 1.85E-04 1.45E-04 6.70E-13 La-140 1.59E-01 7.80E-02 2.07E-02 0.OOE+00 O.OOE+00 O.OOE+00 4.48E+03 La-142 8.16E-03 3.63E-03 9.03E-04 O.OOE+00 0.OOE+0 0.OOE+00 1.1OE+02 Ce-141 2.43E-02 1.62E-02 1.86E-03 0.OOE+00 7.62E-03 O.OOE+00 4.63E+01 Ce-143 4.29E-03 3.12E+00 3.48E-04 0.OOE+00 1.40E-03 O.OOE+00 9.38E+01 Ce-144 1.27E+00 5.25E-01 6.82E-02 O.OOE+00 3.14E-01 0.OOE+00 3.19E+02 Pr-143 5.97E-01 2.38E-01 2.97E-02 O.OOE+00 1.39E-01 O.OOE+00 1.97E+03 Pr-144 1.96E-03 8.03E-04 9.94E-05 0.OOE+00 4.61E-04 O.OOE+00 2.16E-06 Nd-147 4.28E-01 4.65E-01 2.79E-02 O.OOE+00 2.73E-01 O.OOE+00 1.68E+03 W-187 3.20E+02 2.60E+02 9.13E+01 O.OOE+00 O.OOE+00 O.OOE+00 7.05E+04 Np-239 3.21E-02 3.03E-03 1.68E-03 0.OOE+00 9.50E-03 O.OOE+00 4.87E+02 Notes:

1)

Units are mrem/hr per tCi/ml.

Page 11.3-20

CY-BY-170-301I Revision 8 Table 3-7 Site Specific Fish Ingestion Dose Factors for Child Age Group Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI H-3 O.OOE+00 8.21E-02 8.21E-02 8.21E-02 8.21E-02 8.21E-02 8.21E-02 Na-24 4.56E+02 4.56E+02 4.56E+02 4.56E+02 4.56E+02 4.56E+02 4.56E+02 Cr-51 O.OOE+00 O.OOE+00 1.40E+00 7.77E-01 2.12E-01 1.42E+00 7.43E+01 Mn-54 O.OOE+00 3.37E+03 8.97E+02 O.OOE+00 9.44E+02 O.OOE+00 2.83E+03 Mn-56 O.OOE+00 1.05E+02 2.37E+01 O.OOE+00 1.27E+02 O.OOE+00 1.52E+04 Fe-55 9.05E+02 4.80E+02 1.49E+02 O.OOE+00 O.OOE+00 2.71E+02 8.89E+O1 Fe-59 1.30E+03 2.1OE+03 1.05E+03 O.OOE+O0 O.OOE+00 6.09E+02 2.19E+03 Co-58 O.OOE+00 7.08E+01 2.17E+02 0.00E+00 O.OOE+00 O.OOE+00 4.13E+02 Co-60 O.OOE+00 2.08E+02 6.14E+02 O.OOE+00 O.OOE+00 O.OOE+00 1.15E+03 Ni-63 4.23E+04 2.27E+03 1.44E+03 O.OOE+00 O.OOE+00 O.OOE+00 1.53E+02 Ni-65 1.75E+02 1.64E+01 9.60E+00 O.OOE+00 O.OOE+00 O.OOE+0O 2.01E+03 Cu-64 O.OOE+00 9.64E+00 5.82E+00 O.OOE+00 2.33E+01 O.OOE+00 4.52E+02 Zn-65 2.16E+04 5.74E+04 3.57E+04 O.OOE+00 3.62E+04 O.OOE+00 1.01E+04 Zn-69 6.89E+01 9.96E+01 9.20E+00 O.OOE+00 6.04E+01 O.OOE+00 6.28E+03 Br-83 O.OOE+00 O.OOE+00 5.65E+01 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-84 O.OOE+00 O.OOE+00 6.54E+01 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-85 O.OOE+00 O.OOE+00 3.01E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-86 O.OOE+00 1.05E+05 6.48E+04 O.OOE+00 O.OOE+00 O.OOE+00 6.78E+03 Rb-88 O.OOE+00 2.99E+02 2.08E+02 O.OOE+00 O.OOE+O0 O.OOE+00 1.47E+01 Rb-89 0.00E+00 1.84E+02 1.64E+02 O.OOE+00 O.OOE+00 O.OOE+00 1.60E+00 Sr-89 3.11E+04 O.OOE+00 8.90E+02 O.OOE+00 O.OOE+00 O.OOE+00 1.21E+03 Sr-90 6.04E+05 O.OOE+00 1.22E+04 O.OOE+00 O.OOE+00 O.OOE+00 5.40E+03 Sr-91 5.66E+02 O.OOE+00 2.14E+01 O.OOE+00 O.OOE+00 O.OOE+00 1.25E+03 Sr-92 2.13E+02 O.OOE+00 8.54E+00 O.OOE+00 O.OOE+00 O.OOE+00 4.04E+03 Y-90 8.08E-01 O.OOE+00 2.16E-02 O.OOE+00 O.OOE+00 O.OOE+00 2.30E+03 Y-91M 7.51E-03 O.OOE+00 2.73E-04 O.OOE+00 O.OOE+00 O.OOE+00 1.47E+01 Y-91 1.18E+O1 O.OOE+00 3.17E-01 O.OOE+00 O.OOE+00 O.OOE+00 1.58E+03 Y-92 7.08E-02 O.OOE+00 2.03E-03 O.OOE+00 O.OOE+00 O.OOE+00 2.05E+03 Y-93 2.24E-01 O.OOE+00 6.16E-03 O.OOE+00 O.OOE+00 O.OOE+00 3.34E+03 Zr-95 3.O1E-01 6.62E-02 5.89E-02 O.OOE+00 9.47E-02 O.OOE+00 6.90E+01 Zr-97 1.81E-02 2.62E-03 1.55E-03 O.OOE+00 3.76E-03 O.OOE+00 3.97E+02 Nb-95 5.31E+02 2.07E+02 1.48E+02 O.OOE+00 1.94E+02 O.OOE+00 3.82E+05 Mo-99 O.OOE+00 1.05E+02 2.59E+O1 O.OOE+00 2.23E+02 O.OOE+00 8.65E+01 Tc-99M 1.09E-02 2.14E-02 3.54E-01 O.OOE+00 3.1OE-01 1.08E-02 1.22E+01 Tc-101 1.26E-02 1.32E-02 1.68E-01 O.OOE+00 2.25E-01 6.99E-03 4.20E-02 Ru-103 5.75E+00 O.OOE+00 2.21E+00 O.OOE+00 1.45E+01 O.OOE+00 1.49E+02 Ru-105 5.07E-01 O.OOE+00 1.84E-01 O.OOE+00 4.46E+00 O.OOE+00 3.3 1E+02 Ru-106 9.20E+01 0.00E+00 1.15E+O1 O.OOE+00 1.24E+02 O.OOE+OO 1.43E+03 Ag-IIOM 9.75E-01 6.59E-01 5.26E-01 O.OOE+00 1.23E+00 O.OOE+00 7.83E+01 Te-125M 3.59E+03 9.72E+02 4.78E+02 1.01E+03 O.OOE+00 O.OOE+00 3.46E+03 Page 11.3-21

CY-BY-1 70-301 Revision 8 Table 3-7 (continued)

Site Specific Fish Ingestion Dose Factors for Child Age Group Nuclide Bone Liver T Body Thyroid Kidney Lune GI-LLI Te-127M 9.09E+03 2.45E+03 1.08E+03 2.17E+03 2.59E+04 O.OOE+001 7.36E+03 Te-127 1.48E+02 4.OOE+01 3.18E+O1 1.03E+02 4.22E+02 O.OOE+00 5.79E+03 Te-129M 1.53E+04 4.28E+03 2.38E+03 4.94E+03 4.50E+04 O.OOE+00 1.87E+04 Te-129 4.22E+O1 1.18E+-01 1.OOE+01 3.01E+01 1.23E+02 O.OOE+00 2.62E+03 Te-131M 2.27E+03 7.83E+02 8.34E+02 1.61E+03 7.58E+03 0.OOE+00 3.18E+04 Te-131 2.61E+01 7.96E+00 7.77E+00 2.OOE+01 7.90E+01 O.OOE+00 1.37E+02 Te-132 3.18E+03 1.41E+03 1.70E+03 2.05E+03 1.31E+04 O.OOE+00 1.42E+04 1-130 3.45E+01 6.96E+01 3.59E+O1 7.67E+03 1.04E+02 O.OOE+00 3.26E+O1 1-131 2.03E+02 2.04E+02 1.16E+02 6.75E+04 3.35E+02 O.OOE+00 1.82E+01 1-132 9.44E+00 1.73E+01 7.98E+00 8.05E+02 2.65E+01 O.OOE+00 2.04E+01 1-133 6.99E+01 8.64E+01 3.27E+0O1 1.60E+04 1.44E+02 O.OOE+00 3.48E+01 1-134 4.94E+00 9.18E+00 4.22E+00 2.11E+02 1.40E+01 O.OOE+00 6.09E+00 1-135 2.06E+01 3.72E+01 1.76E+I01 3.29E+03 5.70E+01 O.OOE+00 2.83E+01 Cs-134 3.68E+05 6.04E+05 1.27E+05 O.OOE+00 1.87E+05 6.72E+04 3.26E+03 Cs-136 3.70E+04 1.02E+05 6.58E+04 O.OOE+00 5.41E+04 8.07E+03 3.57E+03 Cs-137 5.14E+05 4.92E+05 7.27E+04 0.OOE+00 1.60E+05 5.77E+04 3.08E+03 Cs-138 3.59E+02 4.99E+02 3.16E+02 O.OOE+00 3.5 1E+02 3.78E+01 2.30E+02 Ba-139 1.30E+00 6.95E-04 3.78E-02 O.OOE+00 6.07E-04 4.09E-04 7.52E+01 Ba-140 2.61E+02 2.29E-01 1.53E+01 0.OOE+00 7.46E-02 1.37E-01 1.32E+02 Ba-141 6.29E-01 3.52E-04 2.05E-02 O.OOE+00 3.05E-04 2.07E-03 3.59E-01 Ba-142 2.75E-01 1.98E-04 1.54E-02 O.OOE+00 1.60E-04 1.16E-04 3.59E-03 La-140 1.99E-01 6.94E-02 2.34E-02 0.OOE+00 O.OOE+00 O.OOE+00 1.94E+03 La-142 1.03E-02 3.28E-03 1.03E-03 O.OOE+00 O.OOE+00 O.OOE+00 6.51E+02 Ce-141 3.12E-02 1.56E-02 2.31E-03 0.OOE+00 6.83E-03 O.OOE+00 1.94E+01 Ce-143 5.50E-03 2.98E+00 4.32E-04 O.OOE+00 1.25E-03 0.OOE+00 4.37E+01 Ce-144 1.64E+00 5.13E-01 8.73E-02 0.OOE+00 2.84E-01 O.OOE+00 1.34E+02 Pr-143 7.73E-01 2.32E-01 3.83E-02 0.OOE+00 1.26E-01 0.OOE+00 8.34E+02 Pr-144 2.54E-03 7.85E-04 1.28E-04 O.OOE+00 4.15E-04 0.OOE+00 1.69E+00 Nd-147 5.49E-01 4.44E-01 3.44E-02 0.OOE+00 2.44E-01 0.OOE+00 7.04E+02 W-187 4.05E+02 2.40E+02 1.08E+02 0.OOE+00 O.OOE+00 0.OOE+00 3.37E+04 Np-239 4.13E-02 2.97E-03 2.08E-03 0.OOE+00 8.57E-03 O.OOE+00 2.19E+02 Notes:

1) 2)

Units are mrem/hr per gCi/ml.

The infant age group is assumed to receive no dose through the fish ingestion pathway; therefore, no dose factors are supplied.

Page 11.3-22

CY-BY-170-301I Revision 8 Table 3-8 Bloaccumulation Factors (BFI) to be Used in the Absence of Site-Specific Data Element BF for Freshwater Fish Reference (pCi/kg per pCi/L)

H 9.OE-01 6

Be 2.8E+01 Footnote 2 C

4.6E+03 6

F 2.2E+02 Footnote 16 Na 1.OE+02 6

Mg 2.8E+01 Footnote 2 Al 2.2E+03 Footnote 13 P

1.OE+05 6

Cl 2.2E+02 Footnote 16 Ar NA NA K

1.OE+03 Footnote 1 Ca 2.8E+01 Footnote 2 Sc 2.5E+01 Footnote 3 Ti 3.3E+00 Footnote 4 V

3.OE+04 Footnote 5 Cr 2.OE+02 6

Mn 4.OE+02 6

Fe 1.OE+02 6

Co 5.OE+01 6

Ni 1.0E+02 6

Cu 5.OE+01 6

Zn 2.OE+03 6

Ga 2.2E+03 Footnote 13 Ge 2.4E+03 Footnote 12 As 3.3E+04 Footnote 14 Se 4.OE+02 Footnote 15 Br 4.2E+02 6

Kr NA NA Rb 2.OE+03 6

Sr 3.OE+01 6

Y 2.5E+01 6

Zr 3.3E+00 6

Nb 3.OE+04 6

Mo 1.OE+01 6

Tc 1.5E+01 6

Ru 1.OE+01 6

Rh 1.OE+01 6

Pd 1.OE+02 Footnote 9 Page 11.3-23

CY-BY-170-301 Revision 8 Table 3-8 (cont.)

Bioaccumulation Factors (BFI) to be Used in the Absence of Site-Specific Data Cd 2.OE+03 Footnote 11 In 2.2E+03 Footnote 13 Sn 2.4E+03 Footnote 12 Sb 1.OE+00 98 Ag 2.3E+00 56 Te 4.OE+02 6

I 1.5E+01 6

Xe NA NA Cs 2.OE+03 6

Ba 4.OE+00 6

La 2.5E+01 6

Ce 1.OE+00 6

Pr 2.5E+01 6

Nd 2.5E+01 6

Pm 3.OE+01 98 Sm 3.OE+01 Footnote 3 Eu 1.OE+02 Footnote 3 Gd 2.6E+01 Footnote 3 Dy 2.2E+03 Footnote 3 Er 3.3E+04 Footnote 3 Tm 4.0E+02 Footnote 3 Yb 2.2E+02 Footnote 3 Lu 2.5E+01 Footnote 3 Hf 3.3E+00 Footnote 4 Ta 3.OE+04 Footnote 5 W

1.2E+03 6

Re 2.1 E+02 Footnote 6 Os 5.5E+01 Footnote 7 Ir 3.OE+01 Footnote 8 Pt 1.OE+02 Footnote 9 Au 2.6E+01 Footnote 10 Hg 2.0E+03 Footnote 11 TI 2.2E+03 Footnote 13 Pb 3.OE+02 98 Bi 2.OE+01 98 Ra 5.OE+01 98 Th 3.OE+01 98 U

1.OE+01 98 Np 1.OE+01 6

Am 3.OE+01 98 Page 11.3-24

CY-BY-1 70-301 Revision 8 Footnotes:

NA = It is assumed that noble gases are not accumulated.

In Reference 6, see Table A-1 in the ODCM Training and Reference Material.

A number of bioaccumulation factors could not be found in literature. In this case, the periodic table was used in conjunction with published element values. This method was used for periodic table columns except where there were no values for column 3A so the average of columns 2B and 4A was assigned.

1.

Value is the average of Reference 6 values in literature for H, Na, Rb and Cs.

2.

Value is the average of Ref. 6 values in literature for Sr, Ba and Ref. 98 values for Ra.

3.

Value is the same as the Reference 6 value used for Y.

4.

Value is the same as the Reference 6 value used for Zr.

5.

Value is the same as the Reference 6 value used for Nb.

6.

Value is the average of Reference 6 values in literature for Mn and Tc.

7.

Value is the average of Reference 6 values in literature for Fe and Ru.

8.

Value is the average of Reference 6 values in literature for Co and Rh.

9.

Value is the same as the Reference 6 value used for Ni.

10.

Value is the average of Reference 6 values in literature for Cu and Reference 56 value for Ag.

11.

Value used is the same as the Reference 6 value used for Zn.

12.

Value is the average of Reference 6 value in literature for C and Reference 98 value for Pb.

13.

Value is the average of columns 2B and 4A, where column 2B is the "Reference 6 value for Zn" and column 4A is the average of "Reference 6 value for C and Reference 98 value for Pb".

14.

Value is the average of Ref. 6 value found in literature for P and the Ref. 98 values for Bi and Sb.

15.

Value is the same as the Reference 6 value used for Te.

16.

Value is the average of Reference 6 values found in literature for Br and I.

Page 11.3-25

CY-BY-170-301 Revision 8 4.0 GASEOUS EFFLUENTS 4.1 Gaseous Effluents - General Information This section reviews the offsite radiological limits applicable to the nuclear power stations and presents in detail the equations and procedures used to assess compliance with these limits. This calculational approach uses the methodology of NUREG-0133 (Reference 14), and incorporates certain simplifications such as the use of average meteorology.

4.1.1 Pre-calculated atmospheric transport parameters are based on historical average atmospheric conditions. These historical meteorological conditions have resulted in the dispersion parameters shown in Table 4-1, Table 4-2 and Table 4-8.

4.1.2 The equations and parameters of this section are for use in calculating offsite radiation doses during routine operating conditions. They are not for use in calculating doses due to non-routine releases (e.g., accident releases).

4.1.3 An overview of the required compliance is given in Table 1-1. The dose components are itemized and referenced, and an indication of their regulatory application is noted. Additionally, the locations of dose receivers for each dose component are given in Table 1-2.

4.1.4 Airborne Release Point Classifications The pattern of dispersion of airborne releases is dependent on the height of the release point relative to adjacent structures. Each release point is classified as one of the following three height-dependent types:

" Stack (or Elevated) Release Point (denoted by the letter S or subscript s)

  • Ground Level Release Point (denoted by the letter G or subscript g)
  • Vent (or Mixed Mode) Release Point (denoted by the letter V or subscript v) 4.1.5 Operability and Use of Gaseous Effluent Treatment Systems 1 OCFR50 Appendix I and ODCM Part I require that the ventilation exhaust treatment system and the waste gas holdup system be used when projected offsite doses in 31 days, due to gaseous effluent releases, from each reactor unit, exceed any of the following limits:
  • 0.2 mrad to air from gamma radiation.
  • 0.4 mrad to air from beta radiation.
  • 0.3 mrem to any organ of a member of the public.

Page 11.4-1

CY-BY-170-301 Revision 8 The station must project doses due to gaseous releases from the site at least once per 31 days. The calculational methods shown in sections 4.2.2 and 4.2.3 are used for this dose projection.

4.1.6 For a release attributable to a processing or effluent system shared by more than one reactor unit, the dose due to an individual unit is obtained by proportioning the effluents among the units sharing the system.

4.2 Gaseous Effluents - Dose and Dose Rate Calculation Requirements 4.2.1 Instantaneous Dose Rates 4.2.1.1 Noble Gas: Total Body Dose Rate ODCM Part I limits the total body dose rate due to noble gases in gaseous effluents released from a site to areas at and beyond the site boundary to less than or equal to 500 mrem/yr at all times.

The total body dose rate due to noble gases released in gaseous effluents is calculated by the following expression:

D6T

= *K, {(X/(2), 0,. + (X/Q)l,O,v + (X/0)7 01}

(4-1)

The summation is over noble gas radionuclides i.

Since Byron does not have an elevated release point, the Q0s term is not used.

6TO Total Body Dose Rate [mrem/yr]

Dose rate to the total body due to gamma radiation from noble gas radionuclides released in gaseous effluents.

Qis, QIv, QIg Release Rate [gCi/sec]

Measured release rate of radionuclide I from a stack, vent or ground level release point, respectively.

KI Gamma Total Body Dose Conversion Factor [(mrem/yr)/(pCi/m 3)]

Gamma total body dose factor due to gamma emissions for noble gas radionuclide i. K values are taken from Table 4-28 Relative Concentration Factor [sec/m 3]

Page 11.4-2

CY-BY-170-301 Revision 8 (XIO)s (X/Q)v Radioactivity concentration based on semi-infinite cloud methodology at a (XIQ)g specified location per unit of radioactivity release rate for a stack, vent, or ground level release, respectively. See Table 4-1.

To comply with this specification, the effluent radiation monitor has a setpoint corresponding to an offsite total body dose rate at or below the limit (see Part II Section 2.6). In addition, compliance is assessed by calculating offsite total body dose rate based on periodic samples obtained per station procedures.

4.2.1.2 Noble Gas: Skin Dose Rate ODCM Part I limits the skin dose rate due to noble gases in gaseous effluents released from a site to areas at and beyond the site boundary to less than or equal to a dose rate of 3000 mrem/yr at all times. (See TRM 3.11.f)

The skin dose rate due to noble gases released in gaseous effluents is calculated by the following expression:

ISK ="{L,[ (z/Q)IO,B +(X/O),,ON +(X/Q)0Qg]

(4-2)

+ (1.11) M, [ (w/O)y a,. +(X/a))

1,, +(Z/Q)*Qig]

(

The summation is over noble gas radionuclides i.

6SK Skin Dose Rate [mrem/yr]

Dose rate to skin due to beta and gamma radiation from noble gas radionuclides released in gaseous effluents.

Ll Skin Dose Conversion Factor [(mrem/yr)/(pCi/m 3)]

Skin dose factor due to gamma emissions for noble gas radionuclide i. L values are taken from Table 4-28 M1 Gamma Air Dose Conversion Factor [(mrad/yr)/(AiCi/m 3)]

Gamma air dose rate factor per unit of radioactivity release rate for radionuclide i.

See Table 4-28 for Gamma Air Dose conversion factors (From Table B-1 of Regulatory Guide 1.109).

Since Byron does not have an elevated release point, the Qjs term is not used.

To comply with this specification, gaseous effluent radiation monitors have setpoints corresponding to an offsite skin dose rate at or below the limit (see Part II Section Page 11.4-3

CY-BY-1 70-301 Revision 8 2.6). In addition, compliance is assessed by calculating offsite skin dose rate based on periodic samples obtained per station procedures.

4.2.1.3 Non-Noble Gas Radionuclides: Organ Dose Rate ODCM Part I limits the dose rate to any organ, due to radioactive materials in gaseous effluents released from a site to areas at and beyond the site boundary, to less than or equal to a dose rate of 1500 mrem/yr (See TRM 3.11.f)

Typically the child is considered to be the limiting receptor in calculating dose rate to organs due to inhalation of non-noble gas radionuclides in gaseous effluents.

The dose rate to any child organ due to inhalation is calculated by the following expression:

. NNG D(Ch,,d),(,nha,)j = TR(chld)I(nha,) i(X/O)s O

+(X/O).O),

+ (X/O)g 0,g}

(4-3)

The summation is over non-noble gas radionuclides i.

. NNG D(ch,,d),(,nha,)J Inhalation Dose Rate [mrem/yr]

Dose rate to the child age group from radionuclide i, via the inhalation pathway to organ j due to non-noble gas radionuclides.

R(Chlld)i(Inhal)j Inhalation Dose Factor [(mrem/yr)/(gCi/m 3)]

Inhalation dose factor for child age group for radionuclide i, and organ j.

Inhalation dose factors for non-noble gas radionuclides (child) are shown in Table 4-11 Since Byron does not have an elevated release point, the Q% term is not used.

ODCM Part I requires the dose rate due to non-noble gas radioactive materials in airborne effluents be determined to be within the above limit in accordance with a sampling and analysis program specified in TRM Table T3.11.f-1.

The child organ dose rate due to inhalation is calculated in each sector at the location of the highest offsite x/Q (see Table 4-1). The result for the sector with the highest organ inhalation dose rate is compared to the limit.

Page 11.4-4

CY-BY-1 70-301 Revision 8 4.2.2 Time Averaged Dose from Noble Gas 4.2.2.1 Gamma Air Dose ODCM and TRM limits the gamma air dose due to noble gas effluents released from each reactor unit to areas at and beyond the unrestricted area boundary to the following:

Less than or equal to 5 mrad per calendar quarter.

" Less than or equal to 10 mrad per calendar year.

The gamma air dose due to noble gases released in gaseous effluents is calculated by the following expression:

D, =(3.17E-8)ZM,{ X/Q). A, +(X/Q) A,, +}(X/O)gAg (4-4)

I The summation is over noble gas radionuclides i.

Df Gamma Air Dose [mrad]

Dose to air due to gamma radiation from noble gas radionuclides released in gaseous effluents.

3.17E-8 Conversion Constant (seconds to years) [yr/sec]

MI Gamma Air Dose Conversion Factor [(mrad/yr)/(p.Ci/m 3)]

Gamma air dose rate factor per unit of radioactivity release rate for radionuclide i.

See Table 4-28 for Gamma Air Dose conversion factors (From Table B-1 of Regulatory Guide 1.109).

(X/Q).', (X/Q)y, (X/Q)a Gamma-,/Q Factor [sec/m 3]

Radioactivity concentration based on finite cloud methodology at a specific location per unit of radioactivity release rate from a stack, vent or ground level release, respectively. See Table 4-3 for Gamma-X/Q Factors.

Als, Aiv, Aig Cumulative Radionuclide Release [gCi]

Measured cumulative release of radionuclide I over the time period of interest from a stack, vent, or ground level release point, respectively.

Since Byron does not have an elevated release point, the Ais term is not used.

Page 11.4-5

CY-BY-170-301 I Revision 8 TRM 3.11.g requires determination of cumulative and projected gamma air dose contributions due to noble gases for the current calendar quarter and the current calendar year at least once per 31 days.

Gamma air dose is calculated for the sector with the highest offsite (X/Q)Y and is compared with the Part I limits on gamma air dose.

For a release attributable to a processing or effluent system shared by more than one reactor unit, the dose due to an individual unit is obtained by proportioning the effluents among the units sharing the system.

4.2.2.2 Beta Air Dose TRM Chapter 3.11 limits beta air dose due to noble gases in gaseous effluents released from each reactor unit to areas at and beyond the unrestricted area boundary to the following:

Less than or equal to 10 mrad per calendar quarter.

" Less than or equal to 20 mrad per calendar year.

The beta air dose due to noble gases released in gaseous effluents is calculated by the following expression:

Do= (3.17E-8)E { N[(X/O),, A, + (X/1 A,, + (X/Q* AgJ 1 (4-5)

The summation is over noble gas radionuclides i.

Do Beta Dose [mrad]

Dose to air due to beta radiation from noble gas radionuclides released in gaseous effluents.

3.17E-8 Conversion Constant (seconds to years)

[yr/sec]

N, Beta Air Dose Conversion Factor [(mrad/yr)/(gCi/m 3)]

Beta air dose rate per unit of radioactivity concentration for radionuclide i. See Table 4-28 for Beta Air Dose conversion factors (From Table B-1 of Regulatory Guide 1.109).

Page 11.4-6

CY-BY-170-301 Revision 8 (XIQ)s Relative Concentration Factor [sec/m 3]

(X/Q)v (X,/O)g Radioactivity concentration based on semi-infinite cloud methodology at a specified location per unit of radioactivity release rate for a stack, vent, or ground level release, respectively. See Table 4-1.

Ala, Aiv, Aig Cumulative Radionuclide Release [gCi]

Measured cumulative release of radionuclide i over the time period of interest from a stack, vent, or ground level release point, respectively.

Since Byron does not have an elevated release point, the Ais term is not used.

TRM 3.11.g requires determination of cumulative and projected beta air dose contributions due to noble gases for the current calendar quarter and the current calendar year at least once per 31 days.

Beta air dose is calculated for the sector with the highest offsite (XIQ) and is compared with the ODCM Part I limit on beta air dose.

For a release attributable to a processing or effluent system shared by more than one reactor unit, the dose due to an individual unit is obtained by proportioning the effluents among the units sharing the system.

4.2.2.3 Whole Body Dose The total body dose, to any receiver is due, in part, to gamma radiation emitted from radioactivity in airborne effluents. This component is added to others to demonstrate compliance to the requirements of 40CFR190 and 10CFR20.

The total body dose component due to gamma radiation from noble gases released in gaseous effluents is calculated by the following expression:

DT8 = (3.17E -8)

'K, I(X/0)' fA,. + (X/Q)yA,, + (XIO)fA,9 (4-6)

The summation is over noble gas radionuclides i.

DTD Total Body Dose [mrem]

Dose to the total body due to gamma radiation from noble gas radionuclides released in gaseous effluents.

3.17E-8 Conversion Constant (seconds to years) [yr/sec]

K, Gamma Total Body Dose Conversion Factor [(mrem/yr)/(pCi/m 3)]

Page 11.4-7

CY-BY-170-301 Revision 8 Gamma total body dose factor due to gamma emissions for noble gas radionuclide i released from a stack, vent or ground level release point, respectively. See Table 4-28 for Gamma total body dose conversion factors. (From Table B-1 of Regulatory Guide 1.109)

Als, A1v, Aig Cumulative Radionuclide Release [RCi]

Measured cumulative release of radionuclide i over the time period of interest from a stack, vent, or ground level release point, respectively.

The total body dose is also calculated for the 40CFR1 90 and 1 OCFR20 compliance assessments. In some cases, the total body dose may be required in 1 OCFR50 Appendix I assessments (See Part II Table 1-1).

4.2.2.4 Skin Dose There is no regulatory requirement to evaluate skin dose. However, this component is evaluated for reference as there is skin dose design objective contained in 1 OCFR50 Appendix I. Note that in the unlikely event that beta air dose guideline is exceeded, then the skin dose will require evaluation.

The part of skin dose due to noble gases released in gaseous effluents is calculated by the following expression:

DsK = (3.17E-8) T{L,[ (X/o). A1. + (z/0), A1, + (X/Q)g Ag]

(4-7)

+ (1.1 1)M, [ (z/G)y A,. + (X/Qy) A,, + (X/Q)O A, 9] }

The summation is over noble gas radionuclides i.

DSK Skin Dose [mrem]

Dose to the skin due to beta and gamma radiation from noble gas radionuclides released in gaseous effluents.

L, Beta Skin Dose Conversion Factor

[(mrem/yr)/(gCi/m 3)]

Beta skin dose rate per unit of radioactivity concentration for radionuclide

i. Taken from Table 4-28.

1.11 Conversion Constant (rads in air to rem in tissue) [mrem/mrad]

All other terms have been previously defined.

Page 11.4-8

CY-BY-1 70-301 Revision 8 The skin dose is calculated for reference only.

4.2.3 Time Averaged Dose from Non-Noble Gas Radionuclides TRM 3.11 provides the following limits, based on 10CFR50 Appendix I, on the dose to a member of the public from specified non-noble gas radionuclides in gaseous effluents released from each reactor unit to areas at and beyond the unrestricted area boundary:

Less than or equal to 7.5 mrem to any organ during any calendar quarter Less than or equal to 15 mrem to any organ during any calendar year The individual dose components are also required as part of the 40CFR190 assessments and combined as part of the 10CFR20 assessment (Part II Table 1-1).

The dose due to radionuclides deposited on the ground is considered to be a component of the deep dose equivalent for 10CFR20 compliance and an organ (and total body) dose component for 1 OCFR50 Appendix I and 40CFR1 90 compliance.

The dose is calculated for releases in the time period under consideration.

Specifically, the dose is calculated as follows:

DNNG = (3.17E8)_.[WR,piA,. +WVR,pjA j + W8R aipjAi]

(4-8) p I

The summation is over pathways p and non-noble gas radionuclides i.

al Dose Due to Non-Noble Gas Radionuclides [mrem]

Dose due to non-noble gases (radioiodines, tritium and particulates) to age group a, and to organ j.

3.17E-8 Conversion Constant (seconds to years) [yr/sec]

WS, Wv, Wg Relative Concentration Factor Radioactive concentration at a specific location per unit of radioactivity release rate or concentration for stack, vent or ground level release, respectively.

Ws, Wv, or Wg = (X/Q)s, (x/Q)v or (X/Q)g for immersion, inhalation and all tritium pathways.

Ws, Wv, or Wg = (D/Q)9, (D/Q), or (D/Q)g for ground plain and all ingestion pathways.

Page 11.4-9

CY-BY-170-301 Revision 8 (xIQ)s, (x/Q)v, (xIQ)g Relative Concentration Factor [sec/m 3]

Radioactivity concentration based on semi-infinite cloud model at a specified location per unit of radioactivity release rate for a stack, vent, or ground level release, respectively. See Table 4-1 through Table 4-6.

(D/0)8, (D/Q)v, (D/Q)g Relative Deposition Factor [1/M 2]

Radioactivity concentration at a specified location per unit of radioactivity release concentration for a stack, vent, or ground level release, respectively. See Table 4-1 through Table 4-6.

Ralpj Site-Specific Dose Factor [(M 2 mrem/yr)/(giCi/sec)]

or

[(mrem/yr)/(g.Ci/m 3)]

Site-specific dose factor for age group a, nuclide i, pathway p and organ j.

Pathways included are ground plane exposure, inhalation, vegetation ingestion, milk ingestion and meat ingestion. Values of Raipj are provided in Table 4-7 and Table 4-9 through Table 4-26.

Als, Av, Aig Cumulative Radionuclide Release [gCi]

Measured cumulative release of radionuclide i over the time period of interest from a stack, vent, or ground level release point, respectively.

Since Byron does not have an elevated release point, the stack terms for A4., W., (xIQ).,

and (D/Q). are not used.

TRM 3.11.h requires cumulative and projected dose contributions for the current calendar quarter and the current calendar year for the specified non-noble gas radionuclides in airborne effluents to be determined at least once per 31 days.

To comply with this specification, Byron Station obtains and analyzes samples in accordance with the radioactive gaseous waste or gaseous effluent sampling and analysis program (TRM 3.11.f-1). In accordance with NUREG 0133 (Reference 14),

dose due to non-noble gases is assessed at the location in the unrestricted area where the combination of existing pathways and receptor age groups indicates the maximum potential exposure. The inhalation and ground plane exposure pathways are considered to exist at all locations. The food ingestion pathways at a specific location are considered based on their existence as determined by land use census. The values used for (X/Q) and (D/Q) are shown in Table 4-1 through Table 4-6 and correspond to the applicable pathway location.

For a release attributable to a processing or effluent system shared by more than one reactor, the dose due to an individual unit is obtained by proportioning the effluents among the units sharing the system.

Page 11.4-10

CY-BY-170-301 Revision 8 The dose evaluated is also included as part of the 10CFR20 and 40CFR190 assessment (See Part II Section 5).

4.2.3.1 Ground Plane The site-specific dose factor for ground deposition of radioactivity is considered to be a total body dose component and is calculated by the following expression:

R aI(GP)J [D/Q] = K'K" (0.7)DFG, [1 - e-tb

( )

1 X,

.I(49 R,,(Gp)j[D/Q]

Ground Plane Deposition Dose Factor [(M 2 mrem/yr)/(giCi/sec)]

Site-specific ground plane dose factor for age group a, nuclide i and organ

j. The ground plane dose is calculated using (D/Q).

K' Conversion Constant (1 E6 pCi per lCi) [pCi/gCi]

K" Conversion Constant (8760 hr/yr) [hr/yr]

0.7 Shielding Factor; a factor that accounts for dimensionless shielding due to occupancy of structures.

DFGi Ground Plane Dose Conversion Factor [(mrem/hr)/(pCi/M 2)]

Dose rate to the total body per unit of surface radioactivity concentration due to standing on ground uniformly contaminated with radionuclide i. Ground Plane Dose Conversion Factors are shown in Table 4-8.

Note that ground plane dose conversion factors are only given for the total body and no age group. Doses to other organs are assumed to be equal to the total body dose. All age groups are assumed to receive the same dose.

XI Radiological Decay Constant [hr"1]

Radiological decay constant for radionuclide i.

tb Time Period of Ground Deposition [hr]

Time period during which the radioactivity on the ground is assumed to have been deposited (see Part II Table 1-3).

The ground plane exposure pathway is considered to exist at all locations.

Page 11.4-11

CY-BY-170-301 Revision 8 4.2.3.2 Inhalation The site-specific dose factor for inhalation is calculated by the following expression:

R a(,nhal)j [ýjO] = K'BR. DFA.,j (4-10)

Ra(Ina,)jl[Z/Q]

Inhalation Pathway Dose Factor [(mrem/yr)/(gCi/m 3)]

Site-specific inhalation dose factor for age group a, nuclide i and organ j. The inhalation dose is calculated using (X/Q).

K' Conversion Constant (1 E6 pCi per IiCi) [pCi/gCi]

BRa Individual Air Inhalation Rate [m3/yr]

The air intake rate for individuals in age group a. See Table E-5 of Regulatory Guide 1.109.

DFAaij Inhalation Dose Conversion Factor [mrem/pCi]

Dose commitment to an individual in age group a to organ j per unit of activity of radionuclide i inhaled. Taken from Tables E-7 through E-10 of Regulatory Guide 1.109. The value for H-3 is taken from NUREG 4013 (Reference 107).

The inhalation exposure pathway is considered to exist at all locations.

4.2.3.3 Ingestion: Vegetation Food ingestion pathway doses are calculated at locations indicated by the land use census survey. If no real pathway exists within 5 miles of the station, the cow-milk pathway is assumed to be located at 5 miles. Food pathway calculations are not made for sectors in which the offsite regions near the station are over bodies of water.

The dose factor for consumption of vegetables is calculated by the following expression:

R,(v.0)0 [D/01 = K'[ y ( r),] (DFL,,,)[UfLfe-t" + Uf e-'t]

(4-11)

Rai(veg)j [D/Q]

Vegetation Ingestion Pathway Dose Factor

[(M2 mrem/yr)/(gCi/sec)]

Page 11.4-12

CY-BY-170-301 Revision 8 Site-specific vegetation ingestion dose factor for age group a, nuclide i and organ j. With the exception of H-3 and C-14 the vegetation dose is calculated using (D/Q).

K' Conversion Constant (1 E6 pCi per gCi) [pCi/gCi]

r Vegetation Retention Factor [dimensionless]

YV Agricultural Productivity Yield [kg/ M2]

Radiological Decay Constant [1/sec]

Radiological decay constant for radionuclide i XW Weathering Decay Constant [1/sec]

Removal constant for physical loss of activity by weathering. See ODCM Part II Table 1-3.

DFLaij Ingestion Dose Conversion Factor [mrem/pCi]

Ingestion dose conversion factor for age group a, nuclide I and organ j.

Converts pCi ingested to mrem. Taken from Tables E-1 1 though E-14 of Regulatory Guide 1.109. The value for H-3 is taken from NUREG 4013 (Reference 107).

UaL Consumption Rate for Fresh Leafy Vegetation [kg/yr]

Consumption rate for fresh leafy vegetation for age group a.

UaS Consumption Rate for Stored Vegetation

[kg/yr]

Consumption rate for stored vegetation for age group a.

fL Local Leafy Vegetation Fraction [dimensionless]

Fraction of the annual intake of fresh leafy vegetation that is grown locally.

fg Local Stored Vegetation Fraction [dimensionless]

Fraction of the annual intake of stored vegetation that is grown locally.

tL Environmental Transport Time - Fresh Vegetation [sec]

Average time between harvest of leafy vegetation and its consumption.

Page 11.4-13

CY-BY-170-301 Revision 8 th Environmental Transport Time - Stored Vegetation [sec]

Average time between harvest of stored vegetation and its consumption.

The tritium dose from the vegetation pathway must be considered separately as the transport mechanism is based on airborne concentration rather than ground deposition.

The dose factor for the tritium vegetation pathway is:

Ra(H - 3xveg)j[/aQ] = K'... (U fL + Usf,)DFLO(H-3)j[O.75(O.51H)]

(4-12)

R a(H-3Xvegj [*/QA Tritium Vegetation Ingestion Pathway Dose Factor[(m rem/yr)/( IACi/m3)]

Site-specific tritium vegetation ingestion dose factor for age group a and organ J. The tritium vegetation dose is calculated using [IxQ]

K.'

Conversion Constant (1 E3 gm per Kg) [gm/Kg]

H Absolute Atmospheric Humidity [gm/m3]

0.75 Water Fraction [dimensionless]

The fraction of total vegetation that is water.

0.5 Specific Activity Ratio [dimensionless]

The Carbon-14 dose from the vegetation pathway must be considered separately as the transport mechanism is based on airborne concentration rather than ground deposition.

The dose factor for the Carbon-14 vegetation pathway is:

Rv [zlQ]= K'K (ULfL +USf)(DFL )

[011 0.16 (4-12a)

Page 11.4-14

CY-BY-1 70-301 Revision 8 K'

a constant of unit conversion, 1 E 6 pCVuCi K"

gm/kg ua Leafy veg consumption rate adult (kg/yr) fL Fraction of annual intake of fresh, leafy vegetation grown locally Us Stored veg consumption rate adult (kg/yr) fg Fraction of annual intake of stored vegetation grown locally (DFL.)a Ingestion Dose Factors p

The fractional equilibrium ratio (4400 hrs/8760 hrs). The ratio of the total annual release time (for C-14) atmospheric releases to the total annual time during which photosynthesis occurs (taken to be 4400 hrs),

under the condition that the value of p should never exceed unity. For continuous C-14 releases, p is taken to be unity.

0.11 The fraction of total plant mass that is natural carbon (dimensionless) 0.16 The concentration of natural carbon in the atmosphere (gm/m 3) 4.2.3.4 Ingestion Milk The dose factor for consumption of milk is calculated by the following expressions:

R(Mk][D/] -

(F UA.m)

Vs..

[f 8

- tfifje-lthl(-3 Ra(M~k)l[

] - K' 11 +. Fm (r)l(DFL"ii [f" +

y "Pt

(.413)

RaI(MIk)l[D/Q]

Milk Ingestion Pathway Dose Factor

[(M2 mrem/yr)/(gCi/sec)]

Site-specific milk ingestion dose factor for age group a, nuclide i and organ j. With the exception of H-3 and C-14 the milk dose factor is calculated using (D/Q).

K' Conversion Constant (1 E6 pCi per IaCi) [pCi/p.Ci]

OF Feed Consumption [Kg/da]

Amount of feed consumed by milk animal each day. See ODCM Part II Table 1-3.

Uam Milk Consumption Rate [I/yr]

Milk consumption rate for age group a.

Fm Stable Element Transfer Coefficient for Milk [da/I]

Page 11.4-15

CY-BY-170-301 Revision 8 Fraction of animal's daily intake of a particular chemical element that appears in each liter of milk (pCi/I in milk per pCi/da ingested by animal). See ODCM Part II Table 1-4.

fp Pasture Time Fraction [dimensionless]

Fraction of year that animal is on pasture.

fs Pasture Grass Fraction [dimensionless]

Fraction of animal feed that is pasture grass while animal is on pasture.

Yp Agricultural Productivity Yield - Pasture Grass [kg/m 2]

The agricultural productivity by unit area of pasture feed grass.

Ys Agricultural Productivity Yield - Stored Feed [kg/m 2]

The agricultural productivity by unit area of stored feed.

th Environmental Transport Time - Stored Feed [sec]

Average time between harvest to consumption of stored feed by milk animal.

tf Environmental Transport Time - Pasture to Consumption

[sec]

Average time from pasture, to milk animal, to milk, to consumption.

All other terms have been previously defined.

The tritium dose from the milk pathway must be considered separately as the transport mechanism is based on airborne concentration rather than ground deposition. The dose factor for the tritium milk pathway is:

Ra(H-3XM1k)j[x/Q] = K'K-Fm QFUam DFL.(H-3)j [0.75(0.5/H)I (4-14)

R a(H-3)(mill.j [xj(

Tritium Milk Ingestion Pathway Dose Factor

[(m rem/yr)/(Ci/m3)]

Site-specific tritium milk ingestion dose factor for age group a and organ j.

The tritium milk dose is calculated using [X!Q]

K"'

Conversion Constant (1 E3 gm per Kg) [gm/Kg]

H Absolute Atmospheric Humidity [gm/m3]

Page 11.4-16

CY-BY-1 70-301 Revision 8 0.75 Water Fraction [dimensionless]

The fraction of total feed that is water.

0.5 Specific Activity Ratio [dimensionless]

The Carbon-14 dose from the milk pathway must be considered separately as the transport mechanism is based on airborne concentration rather than ground deposition.

The dose factor for the Carbon-14 milk pathway is:

Ric [zIQ]= K'K'" pFmQFUo, (DFL, )J [0.11 /0.16]

(4-14a)

K' a unit of conversion, 1.0E6 pCi/uCi K'"

gm/kg p

The fractional equilibrium ratio (4400 hrs/8760 hrs). The ratio of the total annual release time (for C-

14) atmospheric releases to the total annual time during which photosynthesis occurs (taken to be 4400 hrs), under the condition that the value of p should never exceed unity. For continuous C-14 releases, p is taken to be unity.

F, Stable Element Transfer Data Q;

Milk cow feed consumption rate (kg/day wet)

U, Cow milk consumption rate adult (Vyr)

(DFL)a Ingestion Dose Factors 0.11 The fraction of total plant mass that is natural carbon (dimensionless) 0.16 The concentration of natural carbon in the atmosphere (gm/m 3) 4.2.3.5 Ingestion: Meat The dose factor for consumption of meat is calculated by the following expression:

R,(Mat=)j[D/QI=K, F(UI) F((F L,)fpf. -, (1 -fpf.)e -"'h eX,,, (4-15) ai 10 K'A,+X (DFL., I P

~

1.

R aI(Meat)j [D/Q]

Meat Ingestion Pathway Dose Factor

[(M2 mrem/yr)/(pCi/sec)]

Site-specific meat ingestion dose factor for age group a, nuclide i and organ j. With the exception of H-3 and C-14 the meat dose factor is calculated using (D/Q).

Uaf Meat Consumption Rate [kg/yr]

Page 11.4-17

CY-BY-170-301 Revision 8 Meat consumption rate for age group a.

Ff Stable Element Transfer Coefficient for Meat [da/Kg]

Fraction of animal's daily intake of a particular chemical element that appears in each Kg of meat (pCi/Kg in meat per pCi/da ingested by animal). See ODCM Part II Table 1-4.

th Environmental Transport Time - Stored Feed [sec]

Average time between harvest to consumption of stored feed by meat animal.

tf Environmental Transport Time - Pasture to Consumption [sec]

Average time from pasture, to meat animal, to meat, to consumption.

All other terms have been previously defined.

The tritium dose from the meat pathway must be considered separately as the transport mechanism is based on airborne concentration rather than ground deposition. The dose factor for the tritium meat pathway is:

R a(H-3)(Mearj [Lx Q] = K' K" Ff QF Uaf (DF)a(H-3)j [0.75(0.5/H)]

(4-16)

R a(H-3)(Meatj [I/Q]

Tritium Meat Ingestion Pathway Dose Factor (mrem/yr)/(jtci/m3)]

Site-specific tritium meat ingestion dose factor for age group a and organ j. The tritium meat dose is calculated using z/Q.

K"'

Conversion Constant (1 E3 gm per Kg) [gm/Kg]

H Absolute Atmospheric Humidity [gm/m3]

0.75 Water Fraction [dimensionless]

The fraction of total feed that is water.

0.5 Specific Activity Ratio [dimensionless]

All other terms have been previously defined.

The Carbon-14 dose from the meat pathway must be considered separately as the transport mechanism is based on airborne concentration rather than ground deposition.

The dose factor for the Carbon-14 meat pathway is:

Page 11.4-18

CY-BY-170-301 Revision 8 R [IQ K'K'p F QF Uap (DFL )a [0.11/0.16]

(4.,6a)

K' a unit of conversion, 1.0E6 pCi/uCi K'"

gm/kg p

The fractional equilibrium ratio (4400 hrs/8760 hrs). The ratio of the total annual release time (for C-14) atmospheric releases to the total annual time during which photosynthesis occurs (taken to be 4400 hrs), under the condition that the value of p should never exceed unity. For continuous C-14 releases, p is taken to be unity.

Ft Days/kg for each stable element Or Milk cow feed consumption rate (kg/day wet)

Uo Meat consumption rate adult (kg/yr)

(DFL4)

Ingestion Dose Factors 0.11 the fraction of total plant mass that is natural carbon (dimensionless) 0.16 the concentration of natural carbon in the atmosphere (gm/m 3)

Page 11.4-19

CY-BY-1 70-301 Revision 8 Table 4-1 X/Q and D/Q Maxima at or Beyond the Unrestricted Area Boundary Downwind Nixed Nods(Vent) Release Grourud Level ReLease Direction Radius X/O Radius 0/0 Radius X/O 0/0 (raters) (aec/0/31) Coatera)

(1/MM)

(meters) (Csec/m")

(11/m')

I 1865.

1.981-O?

1675.

1.983-09 1875.

8.6761-07 4.6711E-09 iE 1629.

1.671E-07 1629.

1.921E-09 1329.

7.53111-07

.2712-09 ME 1585.

1.530N-07 1565.

1.8211-09 155.

7.r761-OT 4.3611-09 E

1E 1234.

1.351-07 1234.

1.764E-09 1234.

8.1011-07 5.036E-09 E

122T.

1.611-07 122?.

2.335E-09 122T.

1.1431-06 6.Z261-09 ESE 991.

2.519E-O7 991.

3.540E-09 991.

1.692M-06 9.696-09 SE 1006.

3.0201-07 1006.

3.ST76-09 1006.

2.4801-06 1.1181-01 351 800.

4.4976-07 600.

3.7611-09 600.

4.1511E-06 1.4201-06 9

945.

2.249E-07 945.

2.7921-09 945.

1.9461-06 9.164-09 SSW 97M.

1.476E-07 975.

1.9701-09 915.

1.30S1-06 6.6M11-09 Sia 1067.

1.148E-OT 106?.

I.766-09 1067.

9.279E-07 5.3161-09 WiS 1212.

1.1991-07 1212.

1.9031-09 1212.

T.649-07 5.002E-09 4

1189.

1.7rM8-07 1189.

1.870E-09 1189.

9.3411-07 5.3301-09 1227.

1.2051-07 1227.

1.2921-09 1227.

6.5431-0O 3.745E-09 MW 1128.

1.6861-07 1128.

1.719E-09 1128.

8.801E-07 4.984E-09 uWN 1044.

3.0447-07 1044.

3.2231-09 1044.

1.4321-06 8.871e-09 Byron Site Neteorotog8alt Data 1/75 - 12/78 Note:

Based on "Irrigation from the Rock River" letter from G.P. Lahti (Sargent and Lundy) to J.C. Golden (NSEP), June 4, 1990 and the formulas in Reg. Guide 1.109.

X/Q is used for beta skin, and inhalation dose pathways. See Sections 4.2.1, 4.2.2 and 4.2.3.2.

D/Q is used for produce and leafy vegetable pathways. See Section 4.2.3.

The ground level release data are provided for reference purposes only. Routine dose calculations are performed using mixed mode data.

Radius is the approximate distance from the midpoint between gaseous effluent release points to the location of the highest X/Q or D/Q at or beyond the unrestricted area boundary (UAB).

Page 11.4-20

CY-BY-170-301 Revision 8 Table 4-2 X/Q and D/Q Maxima at or Beyond the Restricted Area Boundary Do-

-Ind Nixed N (odsVent)

Reteas 6e-.ed Level eleahs Direction Radius X/4 Radius v/i Rialis X/4 D/0 (isters) (e*

)~5 (atr)

(1/m")

(aster) (se/*

), I 1 2)

N M7. 6.3571-07 7M7.

7.0041-DO M7. 3.2M-06 !:.036E-08 538.

6.T778-O7 538.

1.0461-05 538.

5.01611-06.1931-08 a

528.

6.803E-07 528.

17012-09 526.

4.3VI-06 ;..646U-0 ENE 474.

5.3413-07 474.

5.9471-09 474.

4.01141-06 V.346-08 E

468.

6.698E-07 466.

7.930E-09 468.

5.359E-06 L.93060-ESE 480.

7.3M7-07 480.

1.9636-09 460.

9.434E-06 X.144E-1 0

SE 427.

1.12U1-06 427.

1-06311-0111 4V7.

11.02411-05 1.3521-06

$811 410.

1.3491-06 410.

6.7441-09 410.

1.301E-05 i6.044E-08 S

25.

1.4411-06 295.

1.1711-08

95.

1.3911-05 9.7107-08 SuS 2"9.

9.32E-P7

29.

.2931[-09

29.

9.376E-06 i).19?1-E0 am 451.

3.9491-07 451.

5.0651-09 451.

3.666E-06 '.0951-08 VM 386.

6.0911-07 356.

7.4251-09 386.

4.699-06 3S.08SE-08 V

379.

1.041E-06 379.

8.116E-09 379.

6.009E-06 3:.271-03 UN 365.

7.4543-07 365.

6.0811-09 365.

4.32E-06 W.57OE-03 NV 445.

T.3941-07 44S.

6.1171-09 445.

4.0681-06 1.1906-01 MUm 45M. 6.1239-07 458.

6,1773-09 65W.

2.9100-0 1.11741-68 Byron Sit@ Neteorutsglcal Data 1/73-1I/v7 Note:

Based on "Irrigation from the Rock River" letter from G.P. Lahti (Sargent and Lundy) to J.C. Golden (NSEP), June 4, 1990 and the formulas in Reg. Guide 1.109.

The ground level release data are provided for reference purposes only. Routine dose calculations are performed using mixed mode data.

Radius is the approximate distance from the midpoint between gaseous effluent release points to the location of the highest X/Q or DIQ at or beyond the restricted area boundary (RAB).

Page 11.4-21

CY-BY-170-301 Revision 8 Table 4-3 Maximum Offsite Gamma-X/Q Downwind Direction N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW Radius (meters) 1875 1829 1585 1234 1227 991 1006 800 945 975 1067 1212 1189 1227 1128 1044 Ground Gamma-XIQ (sec/m**3) 4.80E-07 4.16E-07 4.34E-07 4.83E-07 6.10E-07 8.73E-07 1.24E-06 1.83E-06 9.68E-07 6.69E-07 4.84E-07 4.19E-07 5.07E-07 3.54E-07 4.6 1E-07 7.43E-07 Vent Gamma-X/Q (sec/m**3) 1.46E-07 1.36E-07 1.31 E-07 1.27E-07 1.50E-07 2.13E-07 2.45E-07 3.02E-07 1.85E-07 1.34E-07 1.08E-07 1.11 E-07 1.39E-07 9.70E-08 1.29E-07 2.15E-07 Page 11.4-22

CY-BY-170-301 Revision 8 Table 4-4 X/Q and D/Q at the Nearest Resident Locations within 5 miles Mixed Mode (Vent)

Location Description Direction Distance Ground Level Release Release X/Q D/Q X/Q D/Q Miles meters sec/m 3 m"2 sec/m 3 m"2 NEAREST RESIDENCE N

2.67 4300 3.70E-07 9.80E-10 6.30E-08 3.80E-10 NEAREST RESIDENCE NNE 0.99 1600 1.50E-06 5.30E-09 8.30E-08 1.70E-09 NEAREST RESIDENCE NE 1.18 1900 1.OOE-06 3.40E-09 6.60E-08 1.10E-09 NEAREST RESIDENCE ENE 1.30 2100 8.20E-07 2.20E-09 4.60E-08 7.30E-10 NEAREST RESIDENCE E

1.30 2100 1.20E-06 2.80E-09 5.90E-08 9.40E-10 NEAREST RESIDENCE ESE 1.43 2300 9.10E-07 2.1OE-09 5.10E-08 7.10E-10 NEAREST RESIDENCE SE 0.75 1200 3.60E-06 7.40E-09 6.90E-08 2.00E-09 NEAREST RESIDENCE SSE 0.62 1000 3.80E-06 8.1OE-09 5.40E-08 1.60E-09 NEAREST RESIDENCE S

0.50 800 3.40E-06 1.20E-08 8.40E-08 2.40E-09 NEAREST RESIDENCE SSW 0.62 1000 1.70E-06 6.80E-09 6.40E-08 1.90E-09 NEAREST RESIDENCE SW 0.75 1200 7.80E-07 3.10E-09 3.50E-08 8.80E-10 NEAREST RESIDENCE WSW 1.68 2700 3.30E-07 1.40E-09 5.40E-08 6.50E-10 NEAREST RESIDENCE W

1.68 2700 5.50E-07 1.40E-09 5.20E-08 4.10E-10 NEAREST RESIDENCE WNW 0.75 1200 1.70E-06 5.20E-09 4.60E-08 1.OOE-09 NEAREST RESIDENCE NW 0.99 1600 1.1OE-06 3.30E-09 4.30E-08 7.30E-10 NEAREST RESIDENCE NNW 1.30 2100 8.50E-07 2.90E-09 6.20E-08 7.90E-10 Page 11.4-23

CY-BY-170-301 Revision 8 Table 4-5 X/Q and D/Q at the Nearest Cow Milk Locations within 5 miles Mixed Mode (Vent)

Location Description Direction Distance Ground Level Release Release X/Q D/Q XIQ D/Q miles meters sec/m 3 m 2 sec/m3 m"2 COW MILK N

4.97 8000 1.50E-07 3.20E-10 4.20E-08 1.40E-10 COW MILK NNE 4.97 8000 1.30E-07 3.10E-10 3.90E-08 1.60E-10 COW MILK NE 1.86 3000 5.OOE-07 1.50E-09 6.70E-08 6.20E-10 COW MILK ENE 4.97 8000 1.1OE-07 2.OOE-10 2.90E-08 1.10E-10 COW MILK E

4.97 8000 1.60E-07 2.70E-10 3.90E-08 1.40E-10 COW MILK ESE 4.97 8000 1.40E-07 2.30E-10 3.50E-08 1.20E-10 COW MILK SE 4.97 8000 2.OOE-07 2.70E-10 3.80E-08 1.40E-10 COW MILK SSE 4.97 8000 1.50E-07 2.20E-10 3.10E-08 1.20E-10 COW MILK S

4.78 7700 9.10E-08 2.40E-10 2.90E-08 1.50E-10 COW MILK SSW 4.97 8000 6.10E-08 1.80E-10 2.20E-08 1.20E-10 COW MILK SW 4.97 8000 3.90E-08 1.LOE-10 1.50E-08 7.10E-11 COW MILK WSW 4.97 8000 6.30E-08 2o10E-10 2.50E-08 1.30E-10 COW MILK W

2.49 4000 3.00E-07 7.20E-10 4.90E-08 2.60E-10 COW MILK WNW 3.29 5300 1.70E-07 4.OOE-10 3.40E-08 1.50E-10 COW MILK NW 2.98 4800 2.1OE-07 4.90E-10 3.70E-08 1.80E-10 COW MILK NNW 4.97 8000 1.1OE-07 2.70E-10 3.50E-08 1.20E-10 Page 11.4-24

CY-BY-1 70-301 Revision 8 Table 4-6 X/Q and D/Q at the Nearest Cow Meat Locations within 5 miles Mixed Mode (Vent)

Location Description Direction Distance Ground Level Release Release X/Q D/Q I/Q D/Q miles meters sec/m 3 m"2 sec/m 3 m"2 COW MEAT N

2.98 4800 3.1OE-07 8.10E-10 6,00E-08 3.20E-10 COW MEAT NNE 1.49 2400 7.70E-07 2.60E-09 7.60E-08 9.90E-10 COW MEAT NE 3.42 5500 2.OOE-07 5.30E-10 5120E-08 2.70E-10 COW MEAT ENE 2.30 3700 3.40E-07 8.10E-10 4.30E-08 3.50E-10 COW MEAT E

2.24 3600 5.00E-07 1.10E-09 5.80E-08 4.70E-10 COW MEAT ESE 1.49 2400 8.50E-07 2.OOE-09 5.10E-08 6.80E-10 COW MEAT SE 1.68 2700 9.80E-07 1.80E-09 5.90E-08 6.90E-10 COW MEAT SSE 3.17 5100 2.90E-07 4.90E-10 4.1OE-08 2.40E-10 COW MEAT S

0.56 900 2.80E-06 9.90E-09 7.70E-08

2. 1OE-09 COW MEAT SSW 2.17 3500 2.1OE-07 8.OOE-10 4.OOE-08 4.30E-10 COW MEAT SW 3.17 5100 7.60E-08 2.50E-10 2.1OE-08 1.50E-10 COW MEAT WSW 1.68 2700 3.30E-07 1.40E-09 5.40E-08 6.50E-10 COW MEAT W

1.68 2700 5.50E-07 1.40E-09 5.20E-08 4.10E-10 COW MEAT WNW 3.29 5300 1.70E-07 4.OOE-10 3.40E-08 1.50E-10 COW MEAT NW 3.79 6100 1.50E-07 3.20E-10 3.30E-08 1.30E-10 COW MEAT NNW 1.37 2200 7.90E-07 2.70E-09 6.20E-08 7.50E-10 Page 11.4-25

CY-BY-170-301 Revision 8 Table 4-7 Ground Plane Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI H-3 0.00E+00 0.00E+00 O.OOE+0O 0.00E+00 0.00E+00 0.00E+00 0.00E+00 C-14 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Na-24 1.20E+07 1.20E+07 1.20E+07 1.20E+07 1.20E+07 1.20E+07 1.20E+07 Cr-51 4.65E+06 4.65E+06 4.65E+06 4.65E+06 4.65E+06 4.65E+06 4.65E+06 Mn-54 1.38E+09 1.38E+09 1.38E+09 1.38E+09 1.38E+09 1.38E+09 1.38E+09 Mn-56 9.03E+05 9.03E+05 9.03E+05 9.03E+05 9.03E+05 9.03E+05 9.03E+05 Fe-55 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 Fe-59 2.73E+08 2.73E+08 2.73E+08 2.73E+08 2.73E+08 2.73E+08 2.73E+08 Co-58 3.80E+08 3.80E+08 3.80E+08 3.80E+08 3.80E+08 3.80E+08 3.80E+08 Co-60 2.45E+10 2.45E+10 2.45E+10 2.45E+10 2.45E+10 2.45E+10 2.45E+10 Ni-63 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Ni-65 2.97E+05 2.97E+05 2.97E+05 2.97E+05 2.97E+05 2.97E+05 2.97E+05 Cu-64 6.05E+05 6.05E+05 6.05E+05 6.05E+05 6.05E+05 6.05E+05 6.05E+05 Zn-65 7.46E+08 7.46E+08 7.46E+08 7.46E+08 7.46E+08 7.46E+08 7.46E+08 Zn-69 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Br-83 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 Br-84 2.03E+05 2.03E+05 2.03E+05 2.03E+05 2.03E+05 2.03E+05 2.03E+05 Br-85 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Rb-86 9.01E+06 9.01E+06 9.01E+06 9.01E+06 9.01E+06 9.01E+06 9.01E+06 Rb-88 3.31E+04 3.31E+04 3.31E E+04 3.31E+04 3.31E+04 3.31E E+04 3.31E+04 Rb-89 1.23E+05 1.23E+05 1.23E+05 1.23E+05 1.23E+05 1.23E+05 1.23E+05 Sr-89 2.16E+04 2.16E+04 2.16E+04 2.16E+04 2.16E+04 2.16E+04 2.16E+04 Sr-90 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 Sr-91 2.14E+06 2.14E+06 2.14E+06 2.14E+06 2.14E+06 2.14E+06 2.14E+06 Sr-92 7.76E+05 7.76E+05 7.76E+05 7.76E+05 7.76E+05 7.76E+05 7.76E+05 Y-90 4.50E+03 4.50E+03 4.50E+03 4.50E+03 4.50E+03 4.50E+03 4.50E+03 Y-91M I.OOE+05 1.OOE+05 1.OOE+05 1.OOE+05 I.OOE+05 I.OOE+05 1.OOE+05 Y-91 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 Y-92 1.80E+05 1.80E+05 1.80E+05 1.80E+05 1.80E+05 1.80E+05 1.80E+05 Y-93 1.83E+05 1.83E+05 1.83E+05 1.83E+05 1.83E+05 1.83E+05 1.83E+05 Zr-95 2.45E+08 2.45E+08 2.45E+08 2.45E+08 2.45E+08 2.45E+08 2.45E+08 Zr-97 2.96E+06 2.96E+06 2.96E+06 2.96E+06 2.96E+06 2.96E+06 2.96E+06 Nb-95 1.37E+08 1.37E+08 1.37E+08 1.37E+08 1.37E+08 1.37E+08 1.37E+08 Mo-99 3.99E+06 3.99E+06 3.99E+06 3.99E+06 3.99E+06 3.99E+06 3.99E+06 Tc-99M 1.84E+05 1.84E+05 1.84E+05 1.84E+05 1.84E+05 1.84E+05 1.84E+05 Tc-101 2.03E+04 2.03E+04 2.03E+04 2.03E+04 2.03E+04 2.03E+04 2.03E+04 Ru-103 1.08E+08 1.08E+08 1.08E+08 1.08E+08 1.08E+08 1.08E+08 1.08E+08 Ru-105 6.36E+05 6.36E+05 6.36E+05 6.36E+05 6.36E+05 6.36E+05 6.36E+05 Ru-106 4.22E+08 4.22E+08 4.22E+08 4.22E+08 4.22E+08 4.22E+08 4.22E+08 Ag-lOMI 3.45E+09 3.45E+09 3.45E+09 3.45E+09 3.45E+09 3.45E+09 3.45E+09 Page 11.4-26

CY-BY-1 70-301 Revision 8 Table 4-7 (Continued)

Ground Plane Dose Factors (same for all age groups)

Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-125M 1.56E+06 1.56E+06 1.56E+06 1.56E+06 1.56E+06 1.56E+06 1.56E+06 Te-127M 9.16E+04 9.16E+04 9.16E+04 9.16E+04 9.16E+04 9.16E+04 9.16E+04 Te-127 2.99E+03 2.99E+03 2.99E+03 2.99E+03 2.99E+03 2.99E+03 2.99E+03 Te-129M 1.98E+07 1.98E+07 1.98E1+07 1.98E+07 1.98E+07 1.98E+07 1.98E+07 Te-129 2.62E+04 2.62E+04 2.62E+04 2.62E+04 2.62E+04 2.62E+04 2.62E+04 Te-131M 8.02E+06 8.02E+06 8.02E+06 8.02E+06 8.02E+06 8.02E+06 8.02E+06 Te-131 2.92E+04 2.92E+04 2.92E+04 2.92E+04 2.92E+04 2.92E+04 2.92E+04 Te-132 4.22E+06 4.22E+06 4.22E+06 4.22E+06 4.22E+06 4.22E+06 4.22E+06 1-130 5.50E+06 5.50E+06 5.50E+06 5.50E+06 5.50E+06 5.50E+06 5.50E+06 1-131 1.72E+07 1.72E+07 1.72E+07 1.72E+07 1.72E+07 1.72E+07 1.72E+07 1-132 1.25E+06 1.25E+06 1.25E+06 1.25E+06 1.25E+06 1.25E+06 1.25E+06 1-133 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.45E+06 1-134 4.46E+05 4.46E+05 4.46E+05 4.46E+05 4.46E+05 4.46E+05 4.46E+05 1-135 2.53E+06 2.53E+06 2.53E+06 2.53E+06 2.53E+06 2.53E+06 2.53E+06 Cs-134 6.94E+09 6.94E+09 6.94E+09 6.94E+09 6.94E+09 6.94E+09 6.94E+09 Cs-136 1.50E+08 1.50E+08 1.50E+08 1.50E+08 1.50E+08 1.50E+08 1.50E+08 Cs-137 1.76E+10 1.76E+10 1.76E+10 1.76E+10 1.76E+10 1.76E+10 1.76E+10 Cs-138 3.59E+05 3.59E+05 3.59E+05 3.59E+05 3.59E+05 3.59E+05 3.59E+05 Ba-139 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 Ba-140 2.05E+07 2.05E+07 2.05E+07 2.05E+07 2.05E+07 2.05E+07 2.05E+07 Ba-141 4.17E+04 4.17E+04 4.17E+04 4.17E+04 4.17E+04 4.17E+04 4.17E+04 Ba-142 4.44E+04 4.44E+04 4.44E+04 4.44E+04 4.44E+04 4.44E+04 4.44E+04 La-140 1.92E+07 1.92E+07 1.92E+07 1.92E+07 1.92E+07 1.92E+07 1.92E+07 La-142 7.60E+05 7.60E+05 7.60E+05 7.60E+05 7.60E+05 7.60E+05 7.60E+05 Ce-141 1.37E+07 1.37E+07 1.37E+07 1.37E+07 1.37E+07 1.37E+07 1.37E+07 Ce-143 2.31E+06 2.31E+06 2.31E+06 2.31E E+06 2.31E+06 2.31E+06 2.31E+06 Ce-144 6.96E+07 6.96E+07 6.96E+07 6.96E+07 6.96E+07 6.96E+07 6.96E+07 Pr-143 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Pr-144 1.84E+03 1.84E+03 1.84E+03 1.84E+03 1.84E+03 1.84E+03 1.84E+03 Nd-147 8.48E+06 8.48E+06 8.48E+06 8.48E+06 8.48E+06 8.48E+06 8.48E+06 W-187 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.35E+06 Np-239 1.71E+06 1.71E+06 1.71E+06 1.71E+06 1.71E+06 1.71E+06 1.71E+06 Notes:

1) Units are m2 mremryr per I.tCi/sec.
2) All age groups are assumed to receive the same dose.

Page 11.4-27

CY-BY-1 70-301 Revision 8 Table 4-8 External Dose Factors for Standing on Contaminated Ground DFGii (mrem/hr per pCi/ M2)

Whole Body Whole Body Element Dose Factor Reference Element Dose Factor Reference H-3 0.00E+00 6

Be-7 5.95E-10 99 C-14 0.00E+00 6

F-18 1.19E-08 99 Na-22 2.42E-08 99 Na-24 2.50E-08 6

Mg-27 1.14E-08 99 Mg-28 1.48E-08 99 AI-26 2.95E-08 99 AI-28 2.00E-08 99 P-32 0.00E+00 6

CI-38 1.70E-08 99 Ar-41 1.39E-08 99 K-40 2.22E-09 99 K-42 4.64E-09 99 K-43 1.19E-08 99 Ca-47 1.14E-08 99 Sc-44 2.50E-08 99 Sc-46m 1.21 E-09 99 Sc-46 2.24E-08 99 Sc-47 1.46E-09 99 Ti-44 1.95E-09 99 V-48 3.21E-08 99 Cr-51 2.20E-10 6

Mn-52m 2.79E-08 99 Mn-52 3.80E-08 99 Mn-54 5.80E-09 6

Mn-56 1.1OE-08 6

Fe-52 9.12E-09 99 Fe-55 0.00E+00 6

Fe-59 8.00E-09 6

Co-57 1.65E-09 99 Co-58 7.OOE-09 6

Co-60 1.70E-08 6

Ni-63 0.00E+00 6

Ni-65 3.70E-09 6

Cu-64 1.50E-09 6

Cu-67 1.52E-09 99 Cu-68 8.60E-09' Zn-65 4.OOE-09 6

Zn-69m 5.06E-09 99 Zn-69 0.00E+00 6

Ga-66 2.70E-08 99 Ga-67 1.89E-09 99 Ga-68 1.24E-08 99 Ga-72 3.00E-08 99 Ge-77 1.34E-08 99 As-72 2.23E-08 99 As-73 1.16E-10 99 As-74 9.41E-09 99 As-76 6.46E-09 99 As-77 1.79E-10 99 Se-73 1.38E-08 99 Se-75 4.98E-09 99 Br-77 3.84E-09 99 Br-80 2.01 E-09 99 Br-82 3.00E-08 99 Br-83 6.40E-11 6

Br-84 1.20E-08 6

Br-85 0.00E+00 6

Kr-79 3.07E-09 99 Kr-81 1.59E-10 99 Kr-83m 1.42E-11 99 Kr-85m 2.24E-09 99 Kr-85 1.35E-10 99 Kr-87 1.03E-08 99 Kr-88 2.07E-08 99 Kr-90 1.56E-08 99 Rb-84 1.07E-08 99 Rb-86 6.30E-10 6

Rb-87 0.OOE+00 99 Rb-88 3.50E-09 6

Rb-89 1.50E-08 6

Sr-85 6.16E-09 99 Sr-87m 3.92E-09 99 Sr-89 5.60E-13 6

Sr-90 1.84E-11 99 Sr-91 7.10E-09 6

Sr-92 9.00E-09 6

Y-86 4.00E-08 99 Y-87 5.53E-09 99 Y-88 2.88E-08 99 Y-90 2.20E-12 6

Y-91m 3.80E-09 6

Y-91 2.40E-11 6

Y-92 1.60E-09 6

Y-93 5.70E-10 6

Zr-95 5.00E-09 6

Zr-97 5.50E-09 6

Nb-94 1.84E-08 99 Nb-95 5.10E-09 6

Nb-97m 8.57E-09 99 Nb-97 8.48E-09 99 Mo-99 1.90E-09 6

Tc-99m 9.60E-10 6

Tc-101 2.70E-09 6

Tc-104 1.83E-081 Ru-97 2.99E-09 99 Ru-103 3.60E-09 6

Ru-105 4.50E-09 6

Rui/Rh-106 5.76E-093 6, 99 Pc-109 3.80E-10 99 Cc-109 1.12E-10 99 In-11l 5.11 E-09 99 In-115m 2.01 E-09 99 In-116 0.00E+002 Sn-113 1.15E-09 99 Sn-117m 1.96E-08 99 Sn-119m 7.05E-11 99 Sb-117 0.00E+002 Sb-122 2.71E-09' Sb-124 1.16E-08' Sb-125 4.56E-09 99 Sb-126 7.13E-10 99 Ag-108m 1.92E-08 99 Ag-108 1.14E-09 99 Ag-110m 1.80E-08 6

Ag-111 6.75E-10 99 Te-121m 2.65E-09 99 Te-121 6.75E-09 99 Te-123m 1.88E-09 99 Te-125m 3.50E-11 6

Page 11.4-28

CY-BY-1 70-301 Revision 8 Table 4-8 (cont.)

External Dose Factors for Standing on Contaminated Ground DFG, (mrem/hr oer DCi/M2)

Element Te-125 Te-127 Te-129 Te-131 Te-134 1-124 1-130 1-133 1-135 Xe-129m Xe-133m Xe-135m Xe-137 Cs-129 Cs-134 Cs-137/Ba-137m Cs-139 Ba-133m Ba-I35m Ba-137 Ba-La-140 Ba-142 Ce-139 Ce-143 Pr-142 Nc-147 Pm-145 Pm-148 Sm-153 Eu-154 Gc-153 Er-169 Tmi-170 Yb-175 Hf-181 Ta-183 Re-188 Ir-194 Pt-i 97 Au-195 Au-199 Hg-203 TI-206 Pb-203 Pb-212 Bi-206 Bi-214 Th-232 Np-239 Whole Body Dose Factor 0.OOE+002 1.OOE-1 1 7.IOE-10 2.20E-09 1.05E-08 1.23E-08 1.40E-08 3.70E-09 1.20E-08 5.57E-10 4.81E-10 5.23E-09 4.26E-09 3.39E-09 1.20E-08 1.14E-08 4

5.15E-09 8.10E-10 7.26E-10 0.OOE+002 1.71 E-086 7.90E-09 2.04E-09 2.20E-09 1.84E-09 1.OOE-09 3.38E-10 7.22E-09 8.95E-10 1.41 E-08 1.46E-09 6.12E-14 3.41 E-10 4.94E-10 6.67E-09 2.93E-09' 1.89E-09 2.31 E-09 3.57E-10 1.14E-09 1.18E-09 2.89E-09 O.OOE+00 2 3.88E-09 1.91 E-09 3.74E-08 1.71 E-08 8.14E-12 9.50E-10 Reference 6

6 6

99 99 6

6 6

99 99 99 99 99 6

6,99 99 99 99 6

6 99 6

99 6

99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 6

Element Te-127m Te-129m Te-131m Te-1-132 1-123 1-125 1-131 1-134 Xe-127 Xe-131m Xe-133 Xe-135 Xe-138 Cs-132 Cs-t36 Cs-138 Ba-131 Ba-133 Ba-137m Ba-139 Ba-141 La-142 Ce-141 Ce-Pr-144 Pr-143 Nc-149 Pm-148m Pm-149 Eu-152 Eu-155 Dy-157 Er-171 Yb-169 Lu-1i77 Ta-182 W-187 Os-191 Pt-195m Au-195m Au-198 Hg-197 TI-201 TI-208 Pb-210 Pb-214 Bi-207 Ra-226 U-238 Am-241 Whole Body Dose Factor 1.10E-12 7.70E-10 8.40E-09 3.40E-09W 2.12E-09 2.89E-10 2.80E-09 1.60E-08 3.44E-09 2.13E-10 5.91 E-10 3.36E-09 1.30E-08 8.40E-09 1.50E-08 2.10E-08 5.74E-09 4.85E-09 7.17E-09 2.40E-09 4.30E-09 1.50E-08 5.50E-10 5.20E-107 0.00E+00 5.32E-09 2.35E-08 5.32E-10 1.30E-08 8.27E-10 4.39E-09 5.11 E-09 4.12E-09 4.60E-10 1.42E-08 3.10E-09 9.83E-10 9.79E-10 2.54E-09 5.19E-09 9.33E-10 1.24E-09 3.58E-08 3.57E-11 3.18E-09.

1.77E-08 8.78E-11 7.98E-12 3.48E-10 Reference 6

6 6

6 99 99 6

6 99 99 99 99 99 99 6

6 99 99 99 6

6 6

6 6

6 99 99 99 99 99 99 99 99 99 99 6

99 99 99 99 99 99 99 99 99 99 99 99 99 1 Value derived by comparing the percentage and MeV of the nuclide's gammas and then comparing to Cesium-137, as a value was not available in the literature.

2 0.0 due to low yield and short half-life. A value was not available in the literature.

3 Value is the sum of Ru-106 (1.50E-9) and Rh-106 (4.26E-9). The Rh-106 value is from Reference 99 and the Ru-106 value is from Reference 6.

4 Value is the sum of Cs-137 (4.20E-9) and Ba-137m (7.17E-9). The values are from references 6 and 99, respectively.

Page 11.4-29

CY-BY-170-301 Revision 8 Table 4-8 (cont.)

External Dose Factors for Standing on Contaminated Ground DFGij (mrem/hr per pCi/m 2) 5 Value is the sum of Te-132 (1.70E-9) and 1-132 (1.70E-9).

6 Value is the sum of Ba-140 (2.10E-9) and La-140 (1.50E-8) from reference 6. In Reference 6, see Table E-6.

7 Value is the sum of Ce-144 (3.20E-10) and Pr-144 (2.OOE-10) from reference 6.

Note:

Dose assessments for 10CFR20 and 40CFR190 compliance are made for an adult only.

Dose assessments for 10CFR50 Appendix are made using dose factors of Regulatory Guide 1.109 (Reference 6) for all age groups.

Page 11.4-30

CY-BY-1 70-301 Revision 8 Table 4-9 Adult Inhalation Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI H-3 O.OOE+00 7.18E+02 7.18E+02 7.18E+02 7.18E+02 7.18E+02 7.18E+02 C-14 1.82E+04 3.41E+03 3.41E+03 3.41E+03 3.41E+03 3.41E+03 3.41E+03 Na-24 1.02E+04 1.02E+04 1.02E+04 1.02E+04 1.02E+04 1.02E+04 1.02E+04 Cr-51 O.OOE+00 O.OOE+00 1.00E+02 5.95E+01 2.28E+01 1.44E+04 3.32E+03 Mn-54 0.OOE+00 3.96E+04 6.30E+03 O.OOE+00 9.84E+03 1.40E+06 7.74E+04 Mn-56 O.OOE+00 1.24E+00 1.83E-01 O.OOE+00 1.30E+00 9.44E+03 2.02E+04 Fe-55 2.46E+04 1.70E+04 3.94E+03 O.OOE+00 O.OOE+00 7.21E+04 6.03E+03 Fe-59 1.18E+04 2.78E+04 1.06E+04 O.OOE+00 O.OOE+00 1.02E+06 1.88E+05 Co-58 O.OOE+00 1.58E+03 2.07E+03 O.OOE+00 O.OOE+00 9.28E+05 1.06E+05 Co-60 0.OOE+00 1. 15E+04 1.48E+04 O.OOE+00 O.OOE+00 5.97E+06 2.85E+05 Ni-63 4.32E+05 3.14E+04 1.45E+04 O.OOE+00 O.OOE+00 1.78E+05 1.34E+04 Ni-65 1.54E+00 2.1OE-01 9.12E-02 O.OOE+00 O.OOE+00 5.60E+03 1.23E+04 Cu-64 O.OOE+00 1.46E+00 6.15E-01 O.OOE+00 4.62E+00 6.78E+03 4.90E+04 Zn-65 3.24E+04 1.03E+05 4.66E+04 O.OOE+00 6.90E+04 8.64E+05 5.34E+04 Zn-69 3.38E-02 6.51E-02 4.52E-03 O.OOE+00 4.22E-02 9.20E+02 1.63E+01 Br-83 O.OOE+00 O.OOE+00 2.41E+02 O.OOE+00 O.OOE+00 O.OOE+00 2.32E+02 Br-84 O.OOE+00 O.OOE+00 3.13E+02 O.OOE+00 O.OOE+00 O.OOE+00 1.64E-03 Br-85 O.OOE+O0 O.OOE+00 1.28E+01 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+0O Rb-86 O.OOE+00 1.35E+05 5.90E+04 O.OOE+00 O.OOE+00 O.OOE+00 1.66E+04 Rb-88 0.OOE+00 3.87E+02 1.93E+02 O.OOE+00 O.OOE+00 O.OOE+00 3.34E-09 Rb-89 O.OOE+00 2.56E+02 1.70E+02 O.OOE+00 O.OOE+00 O.OOE+00 9.28E-12 Sr-89 3.04E+05 O.OOE+00 8.72E+03 O.OOE+00 O.OOE+00 1.40E+06 3.50E+05 Sr-90 2.87E+07 O.OOE+00 5.77E+05 O.OOE+00 O.OOE+00 9.60E+06 7.22E+05 Sr-91 6.19E+01 O.OOE+00 2.50E+00 O.OOE+00 O.OOE+00 3.65E+04 1.91E+05 Sr-92 6.74E+00 O.OOE+00 2.91E-01 O.OOE+00 O.OOE+00 1.65E+04 4.30E+04 Y-90 2.09E+03 O.OOE+00 5.61E+O1 O.OOE+00 O.OOE+00 1.70E+05 5.06E+05 Y-91M 2.61E-01 O.OOE+00 1.02E-02 O.OOE+00 O.OOE+00 1.92E+03 1.33E+00 Y-91 4.62E+05 O.OOE+00 1.24E+04 O.OOE+00 O.OOE+00 1.70E+06 3.85E+05 Y-92 1.03E+01 O.OOE+00 3.02E-01 O.OOE+00 O.OOE+00 1.57E+04 7.35E+04 Y-93 9.44E+01 O.OOE+00 2.6 1E+00 O.OOE+00 O.OOE+00 4.85E+04 4.22E+05 Zr-95 1.07E+05 3.44E+04 2.33E+04 O.OOE+00 5.42E+04 1.77E+06 1.50E+05 Zr-97 9.68E+01 1.96E+01 9.04E+00 O.OOE+00 2.97E+01 7.87E+04 5.23E+05 Nb-95 1.41E+04 7.82E+03 4.21E+03 O.OOE+00 7.74E+03 5.05E+05 1.04E+05 Mo-99 O.OOE+00 1.21E+02 2.30E+O1 O.OOE+00 2.91E+02 9.12E+04 2.48E+05 Tc-99M 1.03E-03 2.9 IE-03 3.70E-02 O.OOE+00 4.42E-02 7.64E+02 4.16E+03 Tc-101 4.18E-05 6.02E-05 5.90E-04 O.OOE+00 1.08E-03 3.99E+02 1.09E-1 1 Ru-103 1.53E+03 O.OOE+00 6.58E+02 O.OOE+00 5.83E+03 5.05E+05 1.10E+05 Ru-105 7.90E-01 O.OOE+00 3.1 IE-01 O.OOE+0O 1.02E+00 1.10E+04 4.82E+04 Ru-106 6.91E+04 O.OOE+00 8.72E+03 O.OOE+00 1.34E+05 9.36E+06 9.12E+05 Ag-11OM 1.08E+04 1.00E+04 5.94E+03 O.OOE+00 1.97E+04 4.63E+06 3.02E+05 Page 11.4-31

CY-BY-1 70-301 Revision 8 Table 4-9 (Continued)

Adult Inhalation Dose Factors Liver T Body Thyroid Kidney Nuclide Bone Lung GI-LLI Te-125M 3.42E+03 1.58E+03 4.67E+02 1.05E+03 1.24E+04 3.14E+05 7.06E+04 Te-127M 1.26E+04 5.77E+03 1.57E+03 3.29E+03 4.58E+04 9.60E+05 1.50E+05 Te-127 1.40E+00 6.42E-01 3.10E-01 1.06E+00 5.10E+00 6.51E+03 5.74E+04 Te-129M 9.76E+03 4.67E+03 1.58E+03 3.44E+03 3.66E+04 1.16E+06 3.83E+05 Te-129 4.98E-02 2.39E-02 1.24E-02 3.90E-02 1.87E-01 1.94E+03 1.57E+02 Te-131M 6.99E+01 4.36E+01 2.90E+01 5.50E+01 3.09E+02 1.46E+05 5.56E+05 Te-131 1.11E-02 5.95E-03 3.59E-03 9.36E-03 4.37E-02 1.39E+03 1.84E+01 Te-132 2.60E+02 2.15E+02 1.62E+02 1.90E+02 1.46E+03 2.88E+05 5.10E+05 1-130 4.58E+03 1.34E+04 5.28E+03 1.14E+06 2.09E+04 0.OOE+00 7.69E+03 1-131 2.52E+04 3.58E+04 2.05E+04 1.19E+07 6.13E+04 0.OOE+00 6.28E+03 1-132 1.16E+03 3.26E+03 1.16E+03 1.14E+05 5.18E+03 0.OOE+00 4.06E+02 1-133 8.64E+03 1.48E+04 4.52E+03 2.15E+06 2.58E+04 O.OOE+00 8.88E+03 1-134 6.44E+02 1.73E+03 6.15E+02 2.98E+04 2.75E+03 0.OOE+00 1.01E+00 1-135 2.68E+03 6.98E+03 2.57E+03 4.48E+05 1.1IE+04 0.OOE+00 5.25E+03 Cs-134 3.73E+05 8.48E+05 7.28E+05 O.OOE+00 2.87E+05 9.76E+04 1.04E+04 Cs-136 3.90E+04 1.46E+05 1.10OE+05 0.OOE+00 8.56E+04 1.20E+04 1.17E+04 Cs-137 4.78E+05 6.21E+05 4.28E+05 0.OOE+00 2.22E+05 7.52E+04 8.40E+03 Cs-138 3.31E+02 6.21E+02 3.24E+02 0.OOE+00 4.80E+02 4.86E+01 1.86E-03 Ba-139 9.36E-01 6.66E-04 2.74E-02 O.OOE+00 6.22E-04 3.76E+03 8.96E+02 Ba-140 3.90E+04 4.90E+01 2.57E+03 0.OOE+00 1.67E+01 1.27E+06 2.18E+05 Ba-141 1.OOE-01 7.53E-05 3.36E-03 O.OOE+00 7.OOE-05 1.94E+03 1.16E-07 Ba-142 2.63E-02 2.70E-05 1.66E-03 O.OOE+00 2.29E-05 1.19E+03 1.57E-16 La-140 3.44E+02 1.74E+02 4.58E+01 0.OOE+00 0.OOE+00 1.36E+05 4.58E+05 La-142 6.83E-01 3.10E-01 7.72E-02 0.OOE+00 0.OOE+00 6.33E+03 2.11E+03 Ce-141 1.99E+04 1.35E+04 1.53E+03 0.OOE+00 6.26E+03 3.62E+05 1.20E+05 Ce-143 1.86E+02 1.38E+02 1.53E+01 O.OOE+00 6.08E+01 7.98E+04 2.26E+05 Ce-144 3.43E+06 1.43E+06 1.84E+05 O.OOE+00 8.48E+05 7.78E+06 8.16E+05 Pr-143 9.36E+03 3.75E+03 4.64E+02 O.OOE+00 2.16E+03 2.81E+05 2.OOE+05 Pr-144 3.01E-02 1.25E-02 1.53E-03 0.OOE+00 7.05E-03 1.02E+03 2.15E-08 Nd-147 5.27E+03 6.10E+03 3.65E+02 O.OOE+00 3.56E+03 2.21E+05 1.73E+05 W-187 8.48E+00 7.08E+00 2.48E+00 0.OOE+00 0.OOE+00 2.90E+04 1.55E+05 Np-239 2.30E+02 2.03E+02 1.24E+01 0.OOE+00 7.OOE+01 3.76E+04 1.19E+05 Notes:

1)

Units are mrem/yr per gtCi/m3.

Page 11.4-32

CY-BY-170-301 Revision 8 Table 4-10 Teen Inhalation Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI H-3 O.OOE+00 7.25E+02 7.25E+02 7.25E+02 7.25E+02 7.25E+02 7.25E+02 C-14 2.60E+04 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 Na-24 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 Cr-51 O.OOE+00 O.OOE+00 1.35E+02 7.50E+01 3.07E+01 2. 10E+04 3.00E+03 Mn-54 0.OOE+00 5.11E+04 8.40E1+03 0.OOE+00 1.27E+04 1.98E+06 6.68E+04 Mn-56 0.00E+00 1.70E+00 2.52E-01 0.OOE+00 1.79E+00 1.52E+04 5.74E+04 Fe-55 3.34E+04 2.38E+04 5.54E+03 0.OOE+00 0.OOE+00 1.24E+05 6.39E+03 Fe-59 1.59E+04 3.70E+04 1.43E+04 0.OOE+00 0.OOE+00 1.53E+06 1.78E+05 Co-58 0.00E+00 2.07E+03 2.78E+03 0.OOE+00 0.OOE+00 1.34E+06 9.52E+04 Co-60 0.00E+00 1.51E+04 1.98E+04 0.00E+00 0.OOE+00 8.72E+06 2.59E+05 Ni-63 5.80E+05 4.34E+04 1.98E+04 0.OOE+00 0.00E+00 3.07E+05 1.42E+04 Ni-65 2.18E+00 2.93E-01 1.27E-01 0.OOE+00 0.00E+00 9.36E+03 3.67E+04 Cu-64 0.00E+00 2.03E+00 8.48E-01 0.00E+00 6.41E+00 1.111E+04 6.14E+04 Zn-65 3.86E+04 1.34E+05 6.24E+04 0.00E+00 8.64E+04 1.24E+06 4.66E+04 Zn-69 4.83E-02 9.20E-02 6.46E-03 0.00E+00 6.02E-02 1.58E+03 2.85E+02 Br-83 0.OOE+00 O.OOE+00 3.44E+02 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 Br-84 0.OOE+00 0.OOE+00 4.33E+02 0.OOE+00 0.00E+0010.00E+00 0.00E+00 Br-85 0.00E+00 0.OOE+00 1.83E+01 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 Rb-86 0.OOE+00 1.90E+05 8.40E+04 0.00E+00 0.OOE+00 0.OOE+00 1.77E+04 Rb-88 0.OOE+00 5.46E+02 2.72E+02 0.00E+00 0.OOE+00 0.OOE+00 2.92E-05 Rb-89 0.OOE+00 3.52E+02 2.33E+02 0.00E+00 0.OOE+00 0.00E+00 3.38E-07 Sr-89 4.34E+05 0.00E+00 1.25E+04 0.00E+00 0.OOE+00 2.42E+06 3.71E+05 Sr-90 3.31E+07 0.OOE+00 6.66E+05 0.001E+00 0.00E+00 1.65E+07 7.65E+05 Sr-91 8.80E+01 0.00E+00 3.5 1E+00 0.OOE+00 0.00E+00 6.07E+04 2.59E+05 Sr-92 9.52E+00 0.00E+00 4.06E-01 0.00E+00 0.OOE+00 2.74E+04 1.1913+05 Y-90 2.98E+03 0.00E+00 8.OOE+01 0.OOE+00 0.OOE+00 2.93E+05 5.59E+05 Y-91M 3.70E-01 0.00E+00 1.42E-02 0.00E+00 0.OOE+00 3.20E+03 3.02E+01 Y-91 6.61E+05 0.00E+00 1.77E+040.001E+00 0.OOE+00 2.94E+06 4.09E+05 Y-92 1.47E+01 0.00E+00 4.29E-01 0.OOE+00 0.OOE+00 2.68E+04 1.65E+05 Y-93 1.35E+02 0.00E+00 3.72E+00 0.OOE+00 0.00E+00 8.32E+04 5.79E+05 Zr-95 1.46E+05 4.58E+04 3.15E+04 0.OOE+00 6.74E+04 2.69E+06 1.49E+05 Zr-97 1.38E+02 2.72E+01 1.26E+01 0.OOE+00 4.12E+01 1.30E+05 6.30E+05 Nb-95 1.86E+04 1.03E+04 5.66E+03 0.OOE+00 1.00E+04 7.511E+05 9.68E+04 Mo-99 0.OOE+00 1.6913+02 3.22E+01 0.OOE+00 4.111E+02 1.54E+05 2.69E+05 Tc-99M 1.38E-03 3.86E-03 4.99E-02 0.00E+00 5.76E-02 1.15E+03 6.13E+03 Tc-101 5.92E-05 8.40E-05 8.24E-04 0.00E+00 1.52E-03 6.67E+02 8.7213-07 Ru-103 2.10E+03 0.00E+00 8.96E+02 0.00E+00 7.43E+03 7.83E+05 1.09E+05 Ru-105 1.12E+00 0.OOE+00 4.34E-01 0.OOE+00 1.41E+00 1.82E+04 9.04E+04 Ru-106 9.84E+04 0.00E+00 1.24E+04 0.OOE+00 1.90E+05 1.6 1E+07 9.60E+05 Ag-110M 1.38E+04 1.31E+04 7.99E+03 0.OOE+00 2.50E+04 6.75E+06 2.73E+05 Page 11.4-33

CY-BY-170-301 Revision 8 Table 4-10 (Continued)

Teen Inhalation Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-125M 4.88E+03 2.24E+03 6.67E+02 1.40E+03 0.OOE+00 5.36E+05 7.50E+04 Te-127M 1.80E+04 8.16E+03 2.18E+03 4.38E+03 6.54E+04 1.66E+06 1.59E+05 Te-127 2.01E+00 9.12E-01 4.4213-01 1.42E+00 7.28E+00 1.12E+04 8.08E+04 Te-129M 1.39E+04 6.58E+03 2.2513+03 4.58E+03 5.19E+04 1.98E+06 4.05E+05 Te-129 7.10E-02 3.38E-02 1.76E-02 5.18E-02 2.66E-01 3.30E+03 1.62E+03 Te-131M 9.84E+01 6.01E+01 4.02E+01 7.25E+01 4.3913+02 2.38E+05 6.21E+05 Te-131 1.58E-02 8.32E-03 5.04E-03 1.24E-02 6.18E-02 2.34E+03 1.51E+01 Te-132 3.60E+02 2.90E+02 2.19E+02 2.46E+02 1.95E+03 4.49E+05 4.63E+05 1-130 6.24E+03 1.79E+04 7.17E+03 1.49E+06 2.75E+04 0.00E+00 9.12E+03 1-131 3.54E+04 4.91E+04 2.64E+04 1.46E+07 8.40E+04 0.00E+00 6.49E+03 1-132 1.59E+03 4.38E+03 1.58E+03 1.51E+05 6.92E+03 0.OOE+00 1.27E+03 1-133 1.22E+04 2.05E+04 6.22E+03 2.92E+06 3.59E+04 0.00E+00 1.03E+04 1-134 8.88E+02 2.32E+03 8.40E+02 3.9513+04 3.66E+03 0.OOE+00 2.04E+01 1-135 3.70E+03 9.44E+03 3.49E+03 6.21E+05 1.49E+04 0.00E+00 6.95E+03 Cs-134 5.02E+05 1.13E+06 5.49E+05 0.00E+00 3.75E+05 1.46E+05 9.76E+03 Cs-136 5.15E+04 1.94E+05 1.37E+05 0.OOE+00 1.1013+05 1.78E+04 1.09E+04 Cs-137 6.70E+05 8.48E+05 3.111E+05 0.00E+00 3.04E+05 1.21E+05 8.48E+03 Cs-138 4.66E+02 8.56E+02 4.46E+02 0.OOE+00 6.62E+02 7.87E+01 2.70E-01 Ba-139 1.3413+00 9.44E-04 3.90E-02 O.OOE+00 8.8813-04 6.46E+03 6.45E+03 Ba-140 5.47E+04 6.70E+01 3.52E+03 0.00E+00 2.28E+01 2.03E+06 2.29E+05 Ba-141 1.42E-01 1.06E-04 4.74E-03 0.OOE+00 9.84E-05 3.29E+03 7.46E-04 Ba-142 3.70E-02 3.70E-05 2.27E-03 0.OOE+00 3.14E-05 1.91E+03 4.79E-10 La-140 4.79E+02 2.36E+02 6.26E+01 0.OOE+00 0.00E+00 2.14E+05 4.87E+05 La-142 9.60E-01 4.25E-01 1.06E-01 O.OOE+00 O.OOE+00 1.02E+04 1.20E+04 Ce-141 2.84E+04 1.90E+04 2.17E+03 O.OOE+00 8.88E+03 6.14E+05 1.26E+05 Ce-143 2.66E+02 1.94E+02 2.16E+01 0.OOE+00 8.64E+01 1.30E+05 2.55E+05 Ce-144 4.89E+06 2.02E+06 2.62E+05 0.00E+00 1.21E+06 1.34E+07 8.64E+05 Pr-143 1.34E+04 5.31E+03 6.62E+02 0.00E+00 3.09E+03 4.83E+05 2.14E+05 Pr-144 4.30E-02 1.76E-02 2.18E-03 0.00E+00 1.0IE-02 1.75E+03 2.35E-04 Nd-147 7.8613+03 8.56E+03 5.13E+02 0.OOE+00 5.02E+03 3.72E+05 1.82E+05 W-187 1.20E+01 9.76E+00 3.43E+00 O.00E+00 O.OOE+00 4.74E+04 1.77E+05

=Np-239 3.38E+02 2.88E+02 1.77E+01 0.00E+00 1.00E+02 6.49E+04 1.32E+05 Notes:

1)

Units are mren/yr per gtCi/m 3.

Page 11.4-34

CY-BY-170-301 Revision 8 Table 4-11 Child Inhalation Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lun2 GI-LLI H-3 O.OOE+00 6.40E+02 6.40E+02 6.40EE+02 6.40E+02 6.40E+02 6.40E+02 C-14 3.59E+04 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 Na-24 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 Cr-51 O.OOE+00 O.OOE+00 1.54E+02 8.55E+01 2.43E+01 1.70E+04 1.08E+03 Mn-54 O.OOE+00 4.29E+04 9.5 1E+03 O.OOE+00 1.OOE+04 1.58E+06 2.29E+04 Mn-56 O.OOE+00 1.66E+00 3.12E-01 O.OOE+00 1.67E+00 1.31E+04 1.23E+05 Fe-55 4.74E+04 2.52E+04 7.77E+03 O.OOE+00 O.OOE+00 1.1 IE+05 2.87E+03 Fe-59 2.07E+04 3.34E+04 1.67E+04 O.OOE+00 O.OOE+00 1.27E+06 7.07E+04 Co-58 O.OOE+00 1.77E+03 3.16E+03 O.OOE+00 O.OOE+00 1.1 1E+06 3.44E+04 Co-60 0.OOE+00 1.31E+04 2.26E+04 O.OOE+00 0.OOE+00 7.07E+06 9.62E+04 Ni-63 8.21E+05 4.63E+04 2.80E+04 O.OOE+00 O.OOE+00 2.75E+05 6.33E+03 Ni-65 2.99E+00 2.96E-01 1.64E-01 O.OOE+00 O.OOE+00 8.18E+03 8.40E+04 Cu-64 O.OOE+00 1.99E+00 1.07E+00 O.OOE+00 6.03E+00 9.58E+03 3.67E+04 Zn-65 4.26E+04 1.13E+05 7.03E+04 O.OOE+00 7.14E+04 9.95E+05 1.63E+04 Zn-69 6.70E-02 9.66E-02 8.92E-03 O.OOE+00 5.85E-02 1.42E+03 1.02E+04 Br-83 O.OOE+00 O.OOE+00 4.74E+02 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 Br-84 O.OOE+00 O.OOE+00 5.48E+02 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-85 O.OOE+00 O.OOE+00 2.53E+01 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-86 O.OOE+00 1.98E+05 1.14E+05 O.OOE+00 O.OOE+00 0.00E+00 7.99E+03 Rb-88 O.OOE+00 5.62E+02 3.66E+02 O.OOE+00 O.OOE+00 O.OOE+00 1.72E+01 Rb-89 O.OOE+00 3.45E+02 2.90E+02 O.OOE+00 O.OOE+0O O.OOE+00 1.89E+00 Sr-89 5.99E+05 O.OOE+00 1.72E+04 O.OOE+00 O.OOE+00 2.16E+06 1.67E+05 Sr-90 3.85E+07 O.OOE+00 7.66E+05 O.OOE+00 O.OOE+0O 1.48E+07 3.43E+05 Sr-91 1.2 1E+02 O.OOE+00 4.59E+00 O.OOE+00 O.OOE+00 5.33E+04 1.74E+05 Sr-92 1.31E+01 O.OOE+00 5.25E-01 O.OOE+00 O.OOE+00 2.40E+04 2.42E+05 Y-90 4.11 E+03 O.OOE+00 1.11E+02 O.OOE+0O O.OOE+00 2.62E+05 2.68E+05 Y-91M 5.07E-01 O.OOE+0O 1.84E-02 O.OOE+00 O.OOE+00 2.81E+03 1.72E+03 Y-91 9.14E+05 O.OOE+0O 2.44E+04 O.OOE+00 O.OOE+00 2.63E+06 1.84E+05 Y-92 2.04E+01 O.OOE+00 5.81E-01 O.OOE+00 0.OOE+00 2.39E+04 2.39E+05 Y-93 1.86E+02 O.OOE+00 5.1 IE+00 O.OOE+00 0.OOE+00 7.44E+04 3.89E+05 Zr-95 1.90E+05 4.18E+04 3.70E+04 O.OOE+00 5.96E+04 2.23E+06 6.11E+04 Zr-97 1.88E+02 2.72E+01 1.60E+O1 O.OOE+00 3.89E+01 1.13E+05 3.51E+05 Nb-95 2.35E+04 9.18E+03 6.55E+03 O.OOE+00 8.62E+03 6.14E+05 3.70E+04 Mo-99 O.OOE+00 1.72E+02 4.26E+01 O.OOE+00 3.92E+02 1.35E+05 1.27E+05 Tc-99M 1.78E-03 3.48E-03 5.77E-02 O.OOE+00 5.07E-02 9.51E+02 4.81E+03 Tc-101 8.10E-05 8.51E-05 1.08E-03 O.OOE+00 1.45E-03 5.85E+02 1.63E+01 Ru-103 2.79E+03 O.OOE+00 1.07E+03 O.OOE+00 7.03E+03 6.62E+05 4.48E+04 Ru-105 1.53E+00 O.OOE+00 5.55E-01 O.OOE+00 1.34E+00 1.59E+04 9.95E+04 Ru-106 1.36E+05 O.OOE+00 1.69E+04 O.OOE+00 1.84E+05 1.43E+07 4.29E+05 Ag-I1OM 1.69E+04 1.14E+04 9.14E+03 0.OOE+00 2.12E+04 5.48E+06 1.OOE+05 Page 11.4-35

CY-BY-1 70-301 Revision 8 Table 4-11 (Continued)

Child Inhalation Dose Factors Nuclide Bone Liver T Bodv Thyroid Kidney Lung GI-LLI Te-125M 6.73E+03 2.33E+03 9.14E+02 1.92EE+03 0.OOE+O0 4.77E-i05 3.38E+04 Te-127M 2.49E+04 8.55E+03 3.02E+03 6.07E+03 6.36E+04 1.48E+06 7.14E+04 Te-127 2.77E+00 9.51E-01 6.11E-01 1.96E+00 7.07E+00 1.00E+04 5.62E+04 Te-129M 1.92E+04 6.85E+03 3.04E+03 6.33E+03 5.03E+04 1.76E+06 1.82E+05 Te-129 9.77E-02 3.50E-02 2.38E-02 7.14E-021 2.57E-01 2.93E+03 2.55E+04 Te-131M 1.34E+02 5.92E+01 5.07E+01 9.77E+01 4.OOE+02 2.06E+05 3.08E+05 Te-131 2.17E-02 8.44E-03 6.59E-03 1.70E-02 5.88E-02 2.05E+03 1.33E+03 Te-132 4.81E+02 2.72E+02 2.63E+02 3.17E+02 1.77E+03 3.77E+05 1.38E+05 1-130 8.18E+03 1.64E+04 8.44E+03 1.85E+06 2.45E+04 O.OOE+00 5.11E+03 1-131 4.81E+04 4.81E+04 2.73E+04 1.62E+07 7.88E+04 O.OOE+00 2.84E+03 1-132 2.12E+03 4.07E+03 1.88E+03 1.94E+05 6.25E+03 O.OOE+00 3.20E+03 1-133 1.66E+04 2.03E+04 7.70E+03 3.85E+06 3.38E+04 O.OOE+00 5.48E+03 1-134 1.17E+03 2.16E+03 9.95E+02 5.07E+04 3.30E+03 0.OOE+00 9.55E+02 1-135 4.92E+03 8.73E+03 4.14E+03 7.92E+05 1.34E+04 O.OOE+O0 4.44E+03 Cs-134 6.51E+05 1.01E+06 2.25E+05 O.OOE+00 3.30E+05 1.21E+05 3.85E+03 Cs-136 6.51E+04 1.71E+05 1.16E+05 0.OOE+00 9.55E+04 1.45E+04 4.18E+03 Cs-137 9.07E+05 8.25E+05 1.28E+05 O.OOE+00 2.82E+05 1.04E+05 3.62E+03 Cs-138 6.33E+02 8.40E+02 5.55E+02 O.OOE+00 6.22E+02 6.81E+01 2.70E+02 Ba-139 11.84E+00 9.84E-04 5.37E-02 O.OOE+00 8.62E-04 5.77E+03 5.77E+04 Ba-140 7.40E+04 6.48E+01 4.33E+03 O.OOE+00 2.11E+01 1.74E+06 1.02E+05 Ba-141 1.96E-01 1.09E-04 6.36E-03 O.OOE+00 9.47E-05 2.92E+03 2.75E+02 Ba-142 5.OOE-02 3.60E-05 2.79E-03 O.OOE+00 2.91E-05 1.64E+03 2.74E+00 La-140 6.44E+02 2.25E+02 7.55E+01 O.OOE+00 O.OOE+00 1.83E+05 2.26E+05 La-142 1.30E+00 4.11E-01 1.29E-01 O.OOE+00 O.OOE+00 8.70E+03 7.59E+04 Ce-141 3.92E+04 1.95E+04 2.90E+03 O.OOE+00 8.55E+03 5.44E+05 5.66E+04 Ce-143 3.66E+02 1.99E+02 2.87E+O1 0.OOE+00 8.36E+O1 1.15E+05 1.27E+05 Ce-144 6.77E+06 2.12E+06 3.61E+05 O.OOE+00 1.17E+06 1.20E+07 3.89E+05 Pr-143 1.85E+04 5.55E+03 9.14E+02 O.OOE+00 3.OOE+03 4.33E+05 9.73E+04 Pr-144 5.96E-02 1.85E-02 3.OOE-03 0.OOE+00 9.77E-03 1.57E+03 1.97E+02 Nd-147 1.08E+04 8.73E+03 6.81E+02 O.OOE+00 4.81E+03 3.28E+05 8.21E+04 W-187 1.63E+01 9.66E+00 4.33E+00 0.OOE+00 0.OOE+00 4.11E+04 9.110E+04 Np-239 4.66E+02 3.01E+02 2.35E+01 0.OOE+00 9.73E+01 5.81E+04 6.40E+04 Notes:

1)

Units are mrem/yr per gCi/m3.

Page 11.4-36

CY-BY-170-301 Revision 8 Table 4-12 Infant Inhalation Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI H-3 O.OOE+00 3.68E+02 3.68E+02 3.68E+02 3.68E+02 3.68E-+02 3.68E+02 C-14 2.65E+04 5.31E+03 5.31E E+03 5.31E+03 5.31E+03 5.31E+03 5.31E E+03 Na-24 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 Cr-51 O.OOE+00 O.OOE+00 8.95E+01 5.75E+01 1.32E+01 1.28E+04 3.57E+02 Mn-54 0.OOE+00 2.53E+04 4.98E+03 O.OOE+00 4.98E+03 1.OOE+06 7.06E+03 Mn-56 O.OOE+00 1.54E+00 2.21E-01 O.OOE+00 1.10E+00 1.25E+04 7.17E+04 Fe-55 1.97E+04 1.17E+04 3.33E+03 O.OOE+00 O.OOE+00 8.69E+04 1.09E+03 Fe-59 1.36E+04 2.35E+04 9.48E+03 O.OOE+00 O.OOE+00 1.02E+06 2.48E+04 Co-58 O.OOE+00 1.22E+03 1.82E+03 O.OOE+00 O.OOE+00 7.77E+05 1.1 1E+04 Co-60 O.OOE+00 8.02E+03 1.18E+04 O.OOE+00 O.OOE+00 4.5 1E+06 3.19E+04 Ni-63 3.39E+05 2.04E+04 1.16E+04 O.OOE+00 O.OOE+00 2.09E+05 2.42E+03 Ni-65 2.39E+00 2.84E-01 1.23E-01 O.OOE+00 O.OOE+00 8.12E+03 5.01E+04 Cu-64 O.OOE+00 1.88E+00 7.74E-01 O.OOE+00 3.98E+00 9.30E+03 1.50E+04 Zn-65 1.93E+04 6.26E+04 3.11E+04 O.OOE+00 3.25E+04 6.47E+05 5.14E+04 Zn-69 5.39E-02 9.67E-02 7.18E-03 O.OOE+00 4.02E-02 1.47E+03 1.32E+04 Br-83 O.OOE+00 O.OOE+00 3.81E+02 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-84 O.OOE+00 O.OOE+00 4.OOE+02 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-85 0.OOE+00 O.OOE+00 2.04E+01 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 Rb-86 O.OOE+00 1.90E+05 8.82E+04 O.OOE+00 O.OOE+00 O.OOE+00 3.04E+03 Rb-88 O.OOE+00 5.57E+02 2.87E+02 O.OOE+00 O.OOE+00 O.OOE+00 3.39E+02 Rb-89 O.OOE+00 3.2 IE+02 2.06E+02 O.OOE+00 O.OOE+00 O.OOE+00 6.82E+O1 Sr-89 3.98E+05 O.OOE+00 1.14E+04 O.OOE+0 O.OOE+00 2.03E+06 6.40E+04 Sr-90 1.55E+07 O.OOE+00 3.12E+05 0.OOE+00 O.OOE+00 1.12E+07 1.31E+05 Sr-91 9.56E+01 O.OOE+00 3.46E+00 O.OOE+00 O.OOE+00 5.26E+04 7.34E+04 Sr-92 1.05E+01 O.OOE+00 3.91E-01 O.OOE+0 O.OOE+00 2.38E+04 1.40E+05 Y-90 3.29E+03 O.OOE+00 8.82E+01 O.OOE+0 O.OOE+00 2.69E+05 1.04E+05 Y-91M 4.07E-01 O.OOE+00 1.39E-02 O.OOE+0 O.OOE+00 2.79E+03 2.35E+03 Y-91 5.88E+05 O.OOE+00 1.57E+04 O.OOE+00 O.OOE+00 2.45E+06 7.03E+04 Y-92 1.64E+01 O.OOE+00 4.61E-01 O.OOE+00 0.OOE+00 2.45E+04 1.27E+05 Y-93 1.50E+02 O.OOE+00 4.07E+00 O.OOE+00 O.OOE+00 7.64E+04 1.67E+05 Zr-95

1. 15E+05 2.79E+04 2.03E+04 O.OOE+00 3.11E+04 1.75E+06 2.17E+04 Zr-97 1.50E+02 2.56E+01 1.17E+01 O.OOE+00 2.59E+01 1.10E+05 1.40E+05 Nb-95 1.57E+04 6.43E+03 3.78E+03 O.OOE+00 4.72E+03 4.79E+05 1.27E+04 Mo-99 O.OOE+0 1.65E+02 3.23E+01 O.OOE+00 2.65E+02 1.35E+05 4.87E+04 Tc-99M 1.40E-03 2.88E-03 3.72E-02 O.OOE+00 3.11E-02 8.11E+02 2.03E+03 Tc-101 6.5 1E-05 8.23E-05 8.12E-04 O.OOE+00 9.79E-04 5.84E+02 8.44E+02 Ru-103 2.02E+03 O.OOE+00 6.79E+02 O.OOE+00 4.24E+03 5.52E+05 1.61E+04 Ru-105 1.22E+00 O.OOE+00 4. IOE-01 O.OOE+00 8.99E-01 1.57E+04 4.84E+04 Ru-106 8.68E+04 O.OOE+00 1.09E+04 O.OOE+00 1.07E+05 1.16E+07 1.64E+05 Ag-110M 9.98E+03 7.22E+03 5.OOE+03 0.OOE+00 1.09E+04 3.67E+06 3.30E+04 Page 11.4-37

CY-BY-1 70-301 Revision 8 Table 4-12 (Continued)

Infant Inhalation Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-125M 4.76E+03 1.99E+03 6.58E+02 1.62E+03 O.OOE+00 4.47E+05 1.29E+04 Te-127M 1.67E+04 6.90E+03 2.07E+03 4.87E+03 3.75E+04 1.3 1E+06 2.73E+04 Te-127 2.23E+00 9.53E-01 4.89E-01 1.85E+00 4.86E+00 1.03E+04 2.44E+04 Te-129M 1.41E+04 6.09E+03 2.23E+03 5.47E+03 3.18E+04 1.68E+06 6.90E+04 Te-129 7.88E-02 3.47E-02 1.88E-02 6.75E-02 1.75E-01 3.OOE+03 2.63E+04 Te-131M 1.07E+02 5.50E+01 3.63E+01 8.93E+01 2.65E+02 1.99E+05 1.19E+05 Te-131 1.74E-02 8.22E-03 5.OOE-03 1.58E-02 3.99E-02 2.06E+03 8.22E+03 Te-132 3.72E+02 2.37E+02 1.76E+02 2.79E+02 1.03E+03 3.40E+05 4.41E+04 1-130 6.36E+03 1.39E+04 5.57E+03 1.60E+06 1.53E+04 O.OOE+00 1.99E+03 1-131 3.79E+04 4.44E+04 1.96E+04 1.48E+07 5.18E+04 0.OOE+00 1.06E+03 1-132 1.69E+03 3.54E+03 1.26E+03 1.69E+05 3.95E+03 0.OOE+00 1.90E+03 1-133 1.32E+04 1.92E+04 5.60E+03 3.56E+06 2.24E+04 0.OOE+00 2.16E+03 1-134 9.21E+02 1.88E+03 6.65E+02 4.45E+04 2.09E+03 0.OOE+00 1.29E+03 1-135 3.86E+03 7.60E+03 2.77E+03 6.96E+05 8.47E+03 O.OOE+00 1.83E+03 Cs-134 3.96E+05 7.03E+05 7.45E+04 0.OOE+00 1.90E+05 7.97E+04 1.33E+03 Cs-136 4.83E+04 1.35E+05 5.29E+04 0.OOE+00 5.64E+04 1.18E+04 1.43E+03 Cs-137 5.49E+05 6.12E+05 4.55E+04 0.OOE+00 1.72E+05 7.13E+04 1.33E+03 Cs-138 5.05E+02 7.81E+02 3.98E+02 0.OOE+00 4.10E+02 6.54E+01 8.76E+02 Ba-139 1.48E+00 9.84E-04 4.30E-02 O.OOE+00 5.92E-04 5.95E+03 5.10E+04 Ba-140 5.60E+04 5.60E+01 2.90E+03 O.OOE+00 1.34E+01 1.60E+06 3.84E+04 Ba-141 1.57E-01 1.08E-04 4.97E-03 0.OOE+00 6.50E-05 2.97E+03 4.75E+03 Ba-142 3.98E-02 3.30E-05 1.96E-03 O.OOE+00 1.90E-05 1.55E+03 6.93E+02 La-140 5.05E+02 2.OOE+02 5.15E+01 0.OOE+00 0.OOE+00 1.68E+05 8.48E+04 La-142 1.03E+00 3.77E-01 9.04E-02 0.OOE+00 0.OOE+00 8.22E+03 5.95E+04 Ce-141 2.77E+04 1.67E+04 1.99E+03 0.OOE+00 5.25E+03 5.17E+05 2.16E+04 Ce-143 2.93E+02 1.93E+02 2.21E+01 0.OOE+00 5.64E+01 1.16E+05 4.97E+04 Ce-144 3.19E+06 1.21E+06 1.76E+05 0.OOE+00 5.38E+05 9.84E+06 1.48E+05 Pr-143 1.40E+04 5.24E+03 6.99E+02 0.OOE+00 1.97E+03 4.33E+05 3.72E+04 Pr-144 4.79E-02 1.85E-02 2.41E-03 O.OOE+00 6.72E-03 1.61E+03 4.28E+03 Nd-147 7.94E+03 8.13E+03 5.OOE+02 0.OOE+00 3.15E+03 3.22E+05 3.12E+04 W-187 1.30E+01 9.02E+00 3.12E+00 0.OOE+00 0.OOE+00 3.96E+04 3.56E+04 Np-239 3.71E+02 2.98E+02 1.88E+01 0.OOE+00 6.62E+01 5.95E+04 2.49E+04 Notes:

1)

Units are mren/yr per ptCi/m 3.

Page 11.4-38

CY-BY-1 70-301 Revision 8 Table 4-13 Adult Vegetation Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI H-3 0.00E+00 1.29E+03 1.29E+03 1.29E+03 1.29E+03 1.29E+03 1.29E+03 C-14 8.97E+05 1.79E+05 1.79E+05 1.79E+05 1.79E+05 1.79E+05 1.79E+05 Na-24 2.69E+05 2.69E+05 2.69E+05 2.69E+05 2.69E+05 2.69E+05 2.69E+05 Cr-51 0.OOE+00 0.OOE+00 4.64E+04 2.77E+04 1.02E+04 6.15E+04 1.17E+07 Mn-54 0.OOE+00 3.13E+08 5.97E+07 0.OOE+00 9.31E+07 0.OOE+00 9.58E+08 Mn-56 0.00E+00 1.54E+01 2.73E+00 0.OOE+00 1.95E+01 0.00E+00 4.91E+02 Fe-55 2.10E+08 1.45E+08 3.38E+07 0.00E+00 0.00E+00 8.08E+07 8.3 IE+07 Fe-59 1.26E+08 2.96E+08 1.13E+08 0.00E+00 0.OOE+00 8.27E+07 9.87E+08 Co-58 0.OOE+00 3.08E+07 6.90E+07 0.OOE+00 0.00E+00 0.OOE+00 6.24E+08 Co-60 0.OOE+00 1.67E+08 3.69E+08 0.OOE+00 0.OOE+00 0.00E+00 3.14E+09 Ni-63 1.04E+10 7.21E+08 3.49E+08 0.OOE+00 0.OOE+00 0.OOE+00 1.50E+08 Ni-65 5.97E+01 7.75E+00 3.54E+00 0.00E+00 0.OOE+00 0.00E+00 1.97E+02 Cu-64 0.OOE+0O 9.09E+03 4.27E+03 0.00E+00 2.29E+04 0.00E+00 7.75E+05 Zn-65 3.17E+08 1.01E+09 4.56E+08 0.OOE+00 6.75E+08 0.00E+00 6.36E+08 Zn-69 4.95E-06 9.48E-06 6.59E-07 0.OOE+00 6.16E-06 0.00E+00 1.42E-06 Br-83 0.00E+00 0.00E+00 3.OOE+00 O.OOE+00 0.00E+00 0.00E+00 4.32E+00 Br-84 O.OOE+00 0.00E+00 2.20E-11 0.OOE+00 0.OOE+00 0.OOE+00 1.72E-16 Br-85 0.00E+00 0.OOE+00 0.OOE+0 0.OOE+0 0.001E+0010.00E+00 0.00E+00 Rb-86 0.00E+00 2.20E+08 1.03E+08 0.00E+00 0.OOE+00 0.OOE+00 4.34E+07 Rb-88 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 Rb-89 0.OOE+0 0.001E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.001E+00 Sr-89 9.95E+09 0.00E+00 2.86E+08 0.00E+00 0.00E+00 0.00E+00 1.60E+09 Sr-90 6.95E+11 0.001E+00 1.40E+10 0.00E+00 0.OOE+00 0.00E+00 1.75E+10 Sr-91 3.01E+05 0.OOE+00 1.22E+04 0.00E+00 0.OOE+00 0.OOE+00 1.43E+06 Sr-92 4.12E+02 0.00E+00 1.78E+01 0.OOE+00 0.OOE+00 0.00E+00 8.17E+03 Y-90 1.33E+04 0.OOE+00 3.57E+02 0.OOE+00 0.00E+00 0.OOE+00 1.41E+08 Y-91M 4.93E-09 0.00E+00 1.91E-10 0.OOE+00 0.OOE+00 0.00E+00 1.45E-08 Y-91 5.12E+06 0.OOE+00 1.37E+05 0.00E+00 0.00E+00 0.OOE+00 2.82E+09 Y-92 8.95E-01 0.00E+00 2.62E-02 0.OOE+00 0.OOE+00 0.OOE+00 1.57E+04 Y-93 1.67E+02 0.OOE+00 4.62E+00 0.00E+00 0.00E+00 0.OOE+00 5.31E+06 Zr-95 1.18E+06 3.77E+05 2.55E+05 0.00E+00 5.92E+05 0.00E+00 1.20E+09 Zr-97 3.35E+02 6.77E+01 3.09E+01 0.OOE+00 1.02E+02 0.00E+00 2.10E+07 Nb-95 1.43E+05 7.95E+04 4.27E+04 0.OOE+00 7.86E+04 0.00E+00 4.83E+08 Mo-99 0.00E+00 6.14E+06 1.17E+06 0.OOE+00 1.39E+07 0.00E+00 1.42E+07 Tc-99M 3.06E+00 8.64E+00 1.103E+02 0.00E+00 1.3 1E+02 4.23E+00 5.11E+03 Tc-101 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 Ru-103 4.77E+06 0.00E+00 2.05E+06 0.OOE+00 1.82E+07 0.OOE+00 5.57E+08 Ru-105 5.27E+01 0.00E+00 2.08E+01 0.00E+00 6.81E+02 0.00E+00 3.23E+04 Ru-106 1.93E+08 0.OOE+00 2.44E+07 0.00E+00 3.72E+08 0.00E+00 1.25E+10 Ag-i 10M 1.05E+07 9.75E+06 5.79E+06 0.00E+00 1.92E+07 O.OOE+00 3.98E+09 Page 11.4-39

CY-BY-170-301 Revision 8 Table 4-13 (Continued)

Adult Vegetation Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-125M 9.67E+07 3.50E+07 1.30E+07 2.91E+07 3.93E+08 O.OOE+00 3.86E+08 Te-127M 3.49E+08 1.25E+08 4.26E+07 8.92E+07 1.42E+09 0.OOE+00 1.17E+09 Te-127 5.68E+03 2.04E+03 1.23E+03 4.21E13+03 2.31E+04 0.OOE+00 4.48E+05 Te-129M 2.51E+08 9.37E+07 3.97E+07 8.62E+07 1.05E+09 0.OOE+00 1.26E+09 Te-129 7.14E-04 2.68E-04 1.74E-04 5.48E-04 3.OOE-03 0.OOE+00 5.39E-04 Te-131M 9.09E+05 4.45E+05 3.711E+05 7.04E+05 4.50E+06 0.OOE+00 4.41E+07 Te-131 1.26E-15 5.26E-16 3.97E-16 1.03E-15 5.51E-15 0.OOE+00 1.78E-16 Te-132 4.28E+06 2.77E+06 2.60E+06 3.06E1+06 2.67E+07 0.OOE+00 1.3 1E+08 1-130 3.89E+05 1.15E+06 4.52E+05 9.72E+07 1.79E+06 0.OOE+00 9.87E+05 1-131 8.07E+07 1.15E+08 6.62E+07 3.78E+10 1.98E+08 O.OOE+00 3.05E+07 1-132 5.58E+01 1.49E+02 5.22E+01 5.22E+03 2.38E+02 O.OOE+00 2.80E+01 1-133 2.08E+06 3.62E+06 1.1OE+06 5.32E+08 6.3 IE+06 0.OOE+00 3.25E+06 1-134 8.55E-05 2.32E-04 8.31E-05 4.02E-03 3.69E-04 0.OOE+00 2.02E-07 1-135 3.87E+04 1.01E+05 3.74E+04 6.68E+06 1.62E1+05 O.OOE+00 1.14E+05 Cs-134 4.67E+09 1.11E+10 9.08E+09 O.OOE+00 3.59E+09 1.19E+09 1.94E+08 Cs-136 4.25E+07 1.68E+08 1.21E+08 O.OOE+00 9.33E+07 1.28E+07 1.90E+07 Cs-137 6.36E+09 8.70E+09 5.70E+09 O.OOE+00 2.95E+09 9.81E+08 1.68E+08 Cs-138 3.32E-11 6.56E-11 3.25E-11 0.OOE+00 4.82E-11 4.76E-12 2.80E-16 Ba-139 2.71E-02 1.93E-05 7.92E-04 O.OOE+00 1.80E-05 1.09E-05 4.80E-02 Ba-140 1.29E+08 1.61E+05 8.42E+06 0.OOE+00 5.49E+04 9.24E+04 2.65E+08 Ba-141 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 Ba-142 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 La-140 1.98E+03 9.97E+02 2.63E+02 0.00E+00 0.OOE+00 0.OOE+00 7.32E+07 La-142 1.94E-04 8.83E-05 2.20E-05 0.OOE+00 O.OOE+00 0.OOE+00 6.45E-01 Ce-141 1.97E+05 1.33E+05 1.51E+04 0.00E+00 6.19E+04 0.OOE+00 5.09E+08 Ce-143 9.94E+02 7.35E+05 8.13E+01 0.OOE+00 3.24E+02 0.OOE+00 2.75E+07 Ce-144 3.29E+07 1.38E+07 1.77E+06 O.OOE+00 8.16E+06 0.00E+00 1.1 1E+10 Pr-143 6.27E+04 2.5 1E+04 3.1 1E+03 O.OOE+00 1.45E+04 0.OOE+00 2.75E+08 Pr-144 0.OOE+0O 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Nd-147 3.37E+04 3.90E+04 2.33E+03 0.00E+02 2.28E+0410.OOE+00 1.87E+08 W-187 3.79E+04 3.17E+04 1.11 E+04 0.OOE+00 0.OOE+00 0.OOE+00 1.04E+07 Np-239 1.42E+03 1.40E+02 7.72E+0110.OOE+00 4.37E+020.OOE+0012.87E+07 Notes:

1) 2)

Units are m2 mrem/yr per gCi/sec.

For H-3 and C-14, the units are mrern/yr per pCi/m3.

Page 11.4-40

CY-BY-170-301 Revision 8 Table 4-14 Teen Vegetation Dose Factors Nuclide Bone Liver T Body Thyroid Kidney LunE GI-LLI H-3 0.OOE+00 1.47E+03 1.47E+03 1.47E+03 1.47E+03 1.47E-+03 1.47E+03 C-14 1.45E+06 2.91E+05 2.91E+05 2.91E+05 2.91E+05 2.91E+05 2.91E+05 Na-24 2.39E+05 2.39E+05 2.39E+05 2.39E+05 2.39E+05 2.39E+05 2.39E+05 Cr-51 O.OOE+0 O.OOE+00 6.16E+04 3.42E+04 1.35E+04 8.79E+04 1.03E+07 Mn-54 0.OOE+00 4.54E+08 9.01E+07 O.OOE+00 1.36E+08 O.OOE+00 9.32E+08 Mn-56 0.OOE+00 1.39E+01 2.47E+0 0.OOE+00 1.76E+01 0.OOE+00 9.13E+02 Fe-55 3.26E+08 2.3 IE+08 5.39E+07 0.OOE+00 O.OOE+00 1.47E+08 I.OOE+08 Fe-59 1.79E+08 4.18E+08 1.61E+08 O.OOE+00 0.OOE+00 1.32E+08 9.89E+08 Co-58 0.OOE+00 4.37E+07 1.O0E+08 0.OOE+00 O.OOE+00 0.OOE+00 6.02E+08 Co-60 0.OOE+0O 2.49E+08 5.60E+08 0.OOE+00 O.OOE+00 O.OOE+00 3.24E+09 Ni-63 1.61E+10 1.13E+09 5.45E+08 O.OOE+00 O.OOE+00 0.OOE+00 1.81E+08 Ni-65 5.55E+01 7.1OE+00 3.23E+00 0.OOE+00 O.OOE+00 0.OOE+00 3.85E+02 Cu-64 0.OOE+00 8.24E+03 3.87E+03 O.OOE+00 2.08E+04 0.OOE+00 6.39E+05 Zn-65 14.24E+08 1.47E+09 6.86E+08 O.OOE+00 9.41E+08 0.OOE+00 6.23E+08 Zn-69 4.64E-06 8.84E-06 6.19E-07 O.OOE+00 5.78E-06 0.OOE+00 1.63E-05 Br-83 0.OOE+00 0.OOE+00 2.8 1E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-84 O.OOE+00 O.OOE+00 2.OOE-1 1 0.OOE+0O 0.OOE+00 0.OOE+00 0.OOE+00 Br-85 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 Rb-86 0.OOE+00 2.75E+08 1.29E+08 0.OOE+0O 0.OOE+00 0.OOE+00 4.06E+07 Rb-88 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-89 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+0 O.OOE+00 Sr-89 1.5 IE+10 0.OOE+00 4.33E+08 O.OOE+00 O.OOE+00 O.OOE+00 1.80E+09 Sr-90 9.22E+11 0.OOE+O0 1.84E+10 0.OOE+00 0.OOE+00 O.OOE+00 2.11E+10 Sr-91 2.81E+05 O.OOE+00 1.12E+04 0.OOE+00 0.OOE+00 O.OOE+00 1.27E+06 Sr-92 3.84E+02 0.OOE+00 1.64E+01 O.OOE+00 O.OOE+00 0.OOE+00 9.78E+03 Y-90 1.24E+04 0.OOE+00 3.35E+02 O.OOE+00 0.OOE+00 0.OOE+00 1.02E+08 Y-91M 4.59E-09 0.OOE+00 1.75E-10 0.OOE+00 O.OOE+00 0.OOE+00 2.17E-07 Y-91 7.84E+06 O.OOE+00 2. 1OE+05 O.OOE+00 0.OOE+00 0.OOE+00 3.2 1E+09 Y-92 8.41E-01 0.OOE+00 2.43E-02 0.OOE+00 0.OOE+00 O.OOE+00 2.31E+04 Y-93 1.57E+02 O.OOE+00 4.30E+00 0.OOE+00 0.OOE+00 0.OOE+00 4.80E+06 Zr-95 1.72E+06 5.44E+05 3.74E+05 O.OOE+00 7.99E+05 0.OOE+00 1.26E+09 Zr-97 3.10E+02 6.14E+01 2.83E+01 O.OOE+00 9.31E+01 0.OOE+00 1.66E+07 Nb-95 1.93E+05 1.07E+05 5.90E+04 O.OOE+00 1.04E+05 0.OOE+00 4.58E+08 Mo-99

0.OOE+00 5.63E+06 1.07E+06 0.OOE+00 1.29E+07 0.OOE+00 1.01E+07 Tc-99M 2.70E+00 7.52E+00 9.75E+01 0.OOE+00 1.12E+02 4.17E+00 4.94E+03 Tc-101 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 Ru-103 6.82E+06 O.OOE+00 2.91E+06 0.OOE+00 2.40E+07 O.OOE+00 5.69E+08 Ru-105 4.90E+01 0.OOE+00 1.90E+01 O.OOE+00 6.18E+02 0.OOE+00 3.95E+04 Ru-106 3.09E+08 0.OOE+00 3.90E+07 0.OOE+00 5.97E+08 0.OOE+00 1.48E+10 Ag-ILOM 1.52E+07 1.44E+07 8.73E+06 0.OOE+00 2.74E+07 0.OOE+00 4.03E+09 Page 11.4-41

CY-BY-170-301 Revision 8 Table 4-14 (Continued)

Teen Vegetation Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-125M 1.49E+08 5.35E+07 1.99E+07 4.15E+07 0.OOE+00 0.OOE+00 4.38E+08 Te-127M 5.5 1E+08 1.96E+08 6.56E+07 1.3 1E+08 2.24E+09 0.OOE+00 1.37E+09 Te-127 5.36E+03 1.90E+03 1.15E+03 3.70E+03 2.17E+04 0.OOE+00 4.14E+05 Te-129M 3.61E+08 1.34E+08 5.72E+07 1.17E+08 1.51E+09 0.OOE+00 1.36E+09 Te-129 6.68E-04 2.49E-04 1.63E-04 4.77E-04 2.80E-03 0.OOE+00 3.65E-03 Te-131M 8.42E+05 4.04E+05 3.37E+05 6.07E+05 4.21E+06 0.OOE+00 3.24E+07 Te-131 1.17E-15 4.82E-16 3.66E-16 9.01E-16 5.1IE-15 0.OOE+00 9.60E-17 Te-132 3.89E+06 2.46E+06 2.32E+06 2.60E+06 2.36E+07 0.OOE+00 7.81E+07 1-130 3.47E+05 1.01E+06 4.01E+05 8.20E+07 1.55E+06 0.OOE+00 7.73E+05 1-131 7.68E+07 1.08E+08 5.78E+07 3.14E+10 1.85E+08 0.OOE+00 2.13E+07 1-132 5.03E+01 1.32E+02 4.72E+01 4.43E+03 2.07E+02 0.OOE+00 5.73E+01 1-133 1.93E+06 3.28E+06 1.OOE+06 4.58E+08 5.75E+06 0.OOE+00 2.48E+06 1-134 7.73E-05 2.05E-04 7.36E-05 3.41E-03 3.23E-04 0.00E+00 2.70E-06 1-135 3.49E+04 8.99E+04 3.33E+04 5.78E+06 1.42E+05 O.OOE+00 9.97E+04 Cs-134 7.1OE+09 1.67E+10 7.75E+09 0.00E+00 5.3 1E+09 2.03E+09 2.08E+08 Cs-136 4.35E+07 1.71E+08 1.15E+08 O.OOE+00 9.3 IE+07 1.47E+07 1.38E+07 Cs-137 1.01E+10 1.35E+10 4.69E+09 O.OOE+00 4.59E+09 1.78E+09 1.92E+08 Cs-138 3.07E-11 5.89E-11 2.94E-11 0.OOE+00 4.35E-11 5.06E-12 2.67E-14 Ba-139 2.55E-02 1.79E-05 7.42E-04 O.OOE+00 1.69E-05 1.23E-05 2.27E-01 Ba-140 1.38E+08 1.69E+05 8.90E+06 0.OOE+00 5.74E+04 1.14E+05 2.13E+08 Ba-141 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 Ba-142 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 La-140 1.81E+03 8.88E+02 2.36E+02 0.OOE+00 0.OOE+00 O.OOE+00 5.1OE+07 La-142 1.78E-04 7.92E-05 1.97E-05 0.OOE+00 0.OOE+00 0.OOE+00 2.41E+00 Ce-141 2.83E+05 1.89E+05 2.17E+04 O.OOE+00 8.89E+04 0.OOE+00 5.40E+08 Ce-143 9.29E+02 6.76E+05 7.55E+01 0.OOE+00 3.03E+02 O.OOE+00 2.03E+07 Ce-144 5.27E+07 2.18E+07 2.83E+06 0.OOE+00 1.30E+07 O.OOE+00 1.33E+10 Pr-143 7.01E+04 2.80E+04 3.49E+03 0.OOE+00 1.63E+04 0.OOE+00 2.3 1E+08 Pr-144 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Nd-147 3.67E+04 4.OOE+04 2.39E+03 0.OOE+00 2.35E+04 0.OOE+00 1.44E+08 W-187 3.53E+04 2.87E+04 1.0 IE+04 0.OOE+00 0.OOE+00 0.OOE+00 7.78E+06 Np-239 1.38E+03 1.30E+02 7.24E+01 0.OOE+00 4.09E+02 0.OOE+00 2.10E+07 Notes:

1) 2)

Units are m2 mrem/yr per jtCi/sec.

For H-3 and C-14, the units are mrem/yr per tCi/m3.

Page 11.4-42

CY-BY-170-301 Revision 8 Table 4-15 Child Vegetation Dose Factors Liver T Body Thyroid Kidney Lung GI-LLI Nuclide Bone H-3 0.OOE+00 2.29E+03 2.29E+03 2.29E+03 2.29E+03 2.29E+03 2.29E+03 C-14 3.50E+06 7.01E+05 7.01E+05 7.01E+05 7.01E+05 7.01E+05 7.01E+05 Na-24 3.73E+05 3.73E+05 3.73E+05 3.73E+05 3.73E+05 3.73E+05 3.73E+05 Cr-51 0.00E+00 0.00E+00 1.17E+05 6.49E+04 1.77E+04 1.18E+05 6.20E+06 Mn-54 0.00E+00 6.65E+08 1.77E+08 0.00E+00 1.86E+08 0.00E+00 5.58E+08 Mn-56 0.00E+00 1.82E+01 4.10E+00 0.00E+00 2.20E+01 0.OOE+00 2.63E+03 Fe-55 8.01E+08 4.25E+08 1.32E+08 0.00E+00 O.OOE+00 2.40E+08 7.87E+07 Fe-59 3.97E+08 6.42E+08 3.20E+08 0.00E+00 0.00E+00 1.86E+08 6.69E+08 Co-58 0.OOE+00 6.45E+07 1.97E+08 0.OOE+00 0.OOE+00 0.00E+00 3.76E+08 Co-60 0.OOE+00 3.78E+08 1.12E+09 0.00E+00 0.00E+00 0.00E+00 2.1OE+09 Ni-63 3.95E+10 2.11 1+09 1.34E+09 0.OOE+00 0.OOE+00 0.OOE+00 1.42E+08 Ni-65 1.02E+02 9.59E+00 5.60E+00 0.00E+00 0.OOE+00 0.OOE+00 1.188E+03 Cu-64 0.OOE+00 1.09E+04 6.56E+03 O.OOE+00 2.62E+04 O.OOE+00 5.10E+05 Zn-65 8.12E+08 2.16E+09 1.35E+09 0.00E+00 1.36E+09 0.00E+00 3.80E+08 Zn-69 8.56E-06 1.24E-05 1.14E-06 0.OOE+00 7.50E-06 0.OOE+00 7.80E-04 Br-83 0.OOE+00 0.OOE+00 5.18E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Br-84 0.00E+00 0.OOE+00 3.39E-11 O.OOE+00 0.00E+00 0.00E+00 0.00E+00 Br-85 0.00E+00 O.OOE+00 0.00E+00 O.OOE+00 0.OOE+00 0.00E+00 0.00E+00 Rb-86 0.OOE+00 4.54E+08 2.79E+08 0.OOE+00 0.00E+00 0.00E+00 2.92E+07 Rb-88 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 Rb-89 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+O0 O.OOE+00 0.00E+00 Sr-89 3.59E+10 0.00E+00 1.03E+09 0.OOE+00 0.00E+00 0.00E+00 1.39E+09 Sr-90 1.87E+12 0.OOE+00 3.77E+10 0.00E+00 0.OOE+00 0.OOE+00 1.67E+10 Sr-91 5.17E+05 0.00E+00 1.95E+04 0.00E+00 0.00E+00 0.00E+00 1.14E+06 Sr-92 7.04E+02 0.OOE+00 2.82E+01 0.00E+O0 0.00E+00 0.00E+00 1.33E+04 Y-90 2.3 IE+04 0.OOE+00 6.18E+02 0.00E+00 0.00E+00 0.00E+00 6.57E+07 Y-91M 8.42E-09 0.00E+00 3.06E-10 0.00E+00 0.OOE+00 0.OOE+00 1.65E-05 Y-91 1.87E+07 0.00E+00 4.99E+05 0.00E+00 O.OOE+00 0.00E+00 2.49E+09 Y-92 1.55E+00 O.OOE+00 4.43E-02 0.OOE+00 0.00E+00 0.00E+00 4.47E+04 Y-93 2.89E+02 0.00E+00 7.94E+00 0.00E+00 0.00E+00 0.OOE+00 4.311E+06 Zr-95 3.86E+06 8.50E+05 7.56E+05 0.00E+00 1.22E+06 0.OOE+00 8.86E+08 Zr-97 5.67E+02 8.19E+01 4.83E+01 0.00E+00 1.18E+02 0.OOE+00 1.24E+07 Nb-95 4.12E+05 1.611E+05 1.15E+05 0.OOE+00 1.5 11E+05 0.OOE+00 2.97E+08 Mo-99 0.OOE+00 7.69E+06 1.90E+06 0.OOE+00 1.64E+07 0.00E+00 6.36E+06 Tc-99M 4.64E+00 9.10E+00 1.51E+02 0.OOE+00 1.32E+02 4.62E+00 5.18E+03 Tc-101 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Ru-103 1.53E+07 0.00E+00 5.89E+06 0.OOE+00 3.86E+07 0.00E+00 3.96E+08 Ru-l105 8.97E+01 0.00E+00 3.25E+01 0.00E+00 7.89E+02 0.00E+00 5.86E+04 Ru-106 7.45E+08 0.00E+00 9.30E+07 0.00E+00 1.01E+09 0.OOE+00 1.16E+10 Ag-IIOM 3.21E+07 2.17E+07 1.74E+07 0.00E+00 4.04E+07 0.OOE+00 2.58E+09 Page 11.4-43

CY-BY-170-301 Revision 8 Table 4-15 (Continued)

Child Vegetation Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-125M 3.5 IE+08 9.52E+07 4.68E+07 9.86E+07 O.OOE+0O O.OOE+00 3.39E+08 Te-127M 1.32E+09 3.56E+08 1.57E+08 3.16E+08 3.77E+09 O.OOE+00 1.07E+09 Te-127 9.89E+03 2.67E+03 2.12E+03 6.84E+03 2.81E+04 O.OOE+00 3.86E+05 Te-129M 8.40E+08 2.35E+08 1.30E+08 2.71E+08 2.47E+09 O.OOE+00 1.02E+009 Te-129 1.24E-03 3.45E-04 2.94E-04 8.83E-04 3.62E-03 0.OOE+00 7.70E-02 Te-131M 1.54E+06 5.32E+05 5.66E+05 1.09E+06 5.15E+06 O.OOE+00 2.16E+07 Te-131 2.15E-15 6.57E-16 6.41E-16 1.65E-15 6.51E-15 0.00E+00 1.13E-14 Te-132 6.97E+06 3.09E+06 3.73E+06 4.49E+06 2.86E+07 0.OOE+00 3.11E+07 1-130 6.IOE+05 1.23E+06 6.35E+05 1.36E+08 1.84E+06 0.OOE+00 5.76E+05 1-131 1.43E+08 1.44E+08 8.17E+07 4.75E+10 2.36E+08 O.OOE+0O 1.28E+07 1-132 8.93E+01 1.64E+02 7.54E+01 7.61E+03 2.51E+02 O.OOE+00 1.93E+02 1-133 3.52E+06 4.36E+06 1.65E+06 8.09E+08 7.26E+06 0.OOE+00 1.76E+06 1-134 1.37E-04 2.55E-04 1.17E-04 5.86E-03 3.90E-04 0.OOE+00 1.69E-04 1-135 6.20E+04 1.12E+05 5.28E+04 9.89E+06 1.71E+05 O.OOE+O0 8.51E+04 Cs-134 1.60E+10 2.63E+10 5.55E+09 O.OOE+00 8.16E+09 2.93E+09 1.42E+08 Cs-136 8.18E+07 2.25E+08 1.46E+08 O.OOE+00 1.20E+08 1.79E+07 7.90E+06 Cs-137 12.39E+10 2.29E+10 3.38E+09 O.OOE+00 7.46E+09 2.68E+09 1.43E+08 Cs-138 5.58E-11 7.75E-11 4.92E-11 0.OOE+00 5.45E-11 5.87E-12 3.57E-11 Ba-139 4.69E-02 2.51E-05 1.36E-03 O.OOE+00 2.19E-05 1.47E-05 2.71E+00 Ba-140 2.77E+08 2.43E+05 1.62E+07 O.OOE+00 7.90E+04 1.45E+05 1.40E+08 Ba-141 0.00E+00 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 Ba-142 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 La-140 3.25E+03 1.13E+03 3.82E+02 0.OOE+00 O.OOE+00 O.OOE+00 3.16E+07 La-142 3.23E-04 1.03E-04 3.22E-05 0.OOE+00 0.OOE+00 O.OOE+00 2.04E+01 Ce-141 6.55E+05 3.27E+05 4.85E+04 0.OOE+00 1.43E+05 0.OOE+00 4.08E+08 Ce-143 1.7 IE+03 9.28E+05 1.34E+02 0.OOE+00 3.89E+02 O.OOE+0O 1.36E+07 Ce-144 1.27E+08 3.98E+07 6.78E+06 O.OOE+00 2.21E+07 O.OOE+00 1.04E+10 Pr-143 1.46E+05 4.38E+04 7.24E+03 O.OOE+00 2.37E+04 O.OOE+00 1.57E+08 Pr-144 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Nd-147 7.27E+04 5.89E+04 4.56E+03 0.OOE+00 3.23E+04 0.OOE+00 9.33E+07 W-187 6.41E+04 3.80E+04 1.70E+04 O.OOE+00 0.OOE+00 O.OOE+00 5.34E+06 Np-239 2.55E+03 1.83E+02 1.29E+02 0.OOE+00 5.30E+02 O.OOE+00 1.36E+07 Notes:

1) 2)

3)

Units are m2 mrem/yr per gtCi/sec.

For H-3 and C-14, the units are mrem/yr per ptCi/m 3.

The infant age group is assumed to receive no dose through the vegetation ingestion pathway therefore no dose factors are supplied.

Page 11.4-44

CY-BY-1 70-301 Revision 8 Table 4-16 Adult Grass-Cow-Milk Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Luna GI-LLI H-3 0.OOE+00 4.35E+02 4.35E+02 4.35E+02 4.35E+02 4.35E+02 4.35E+02 C-14 3.63E+05 7.26E+04 7.26E+04 7.26E+04 7.26E+04 7.26E+04 7.26E+04 Na-24 2.46E+06 2,46E+06 2.46E+06 2.46E+06 2.46E+06 2.46E+06 2.46E+06 Cr-51 0.00E+00 0.00E+00 2.86E+04 1.71E+04 6.29E+03 3.79E+04 7.18E+06 Mn-54 0.00E+00 8.41E+06 1.6 IE+06 0.OOE+00 2.50E+06 0.OOE+00 2.58E+07 Mn-56 0.00E+00 4.13E-03 7.32E-04 0.OOE+00 5.24E-03 0.00E+00 1.32E-01 Fe-55 2.5 1E+07 1.74E+07 4.05E+06 0.00E+00 0.00E+00 9.68E+06 9.95E+06 Fe-59 2.97E+07 6.98E+07 2.67E+07 0.OOE+00 0.OOE+00 1.95E+07 2.33E+08 Co-58 0.OOE+00 4.72E+06 1.06E+07 0.OOE+00 0.00E+00 0.003E+00 9.56E+07 Co-60 0.00E+00 1.64E+07 3.62E+07 0.00E+00 0.00E+00 0.00E+00 3.08E+08 Ni-63 6.73E+09 4.66E+08 2.26E+08 0.00E+00 0.OOE+00 0.00E+00 9.73E+07 Ni-65 3.70E-01 4.81E-02 2.19E-02 0.OOE+00 0.00E+00 0.00E+00 1.22E+00 Cu-64 0.OOE+00 2.36E+04 1.11E+04 0.OOE+00 5.95E+04 0.OOE+00 2.01E+06 Zn-65 1.37E+09 4.36E+09 1.97E+09 0.00E+00 2.92E+09 0.00E+00 2.75E+09 Zn-69 2.01E-12 3.84E-12 2.67E-13 0.00E+00 2.50E-12 0.00E+00 5.78E-13 Br-83 0.00E+00 0.00E+00 9.65E-02 0.00E+0010.00E+00 0.00E+00 1.39E-01 Br-84 O.00E+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Br-85 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 Rb-86 0.00E+00 2.60E+09 1.21E+09 0.OOE+00 0.OOE+00 0.00E+00 5.12E+08 Rb-88 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 Rb-89 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 Sr-89 1.45E+09 0.OOE+00 4.16E+07 0.00E+00 0.00E+00 0.OOE+00 2.33E+08 Sr-90 5.38E+10 0.00E+00 1.08E+09 0.00E+00 0.00E+00 0.00E+00 1.35E+09 Sr-91 2.87E+04 0.00E+00 1.16E+03 0.00E+00 0.00E+00 0.00E+00 1.37E+05 Sr-92 4.84E-01 0.00E+00 2.09E-02 0.00E+00 0.00E+00 0.OOE+00 9.58E+00 Y-90 7.103E+01 0.OOE+00 1.90E+00 0.00E+00 0.00E+00 0.00E+00 7.52E+05 Y-91M 6.42E-20 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 1.89E-19 Y-91 8.59E+03 0.00E+00 2.30E+02 0.00E+00 0.00E+00 0.00E+00 4.73E+06 Y-92 5.57E-05 0.00E+00 1.63E-06 0.00E+00 0.00E+00 0.00E+00 9.75E-01 Y-93 2.22E-01 0.001E+00 6.12E-03 0.00E+0010.00E+00 0.00E+00 7.03E+03 Zr-95 9.44E+02 3.03E+02 2.05E+02 0.00E+00 4.75E+02 0.00E+00 9.59E+05 Zr-97 4.32E-01 8.72E-02 3.99E-02 0.00E+00 1.32E-01 0.00E+00 2.70E+04 Nb-95 8.26E+04 4.60E+04 2.47E+04 0.00E+00 4.54E+04 0.00E+00 2.79E+08 Mo-99 0.00E+00 2.47E+07 4.70E+06 0.00E+00 5.60E+07 0.00E+00 5.73E+07 Tc-99M 3.3 1E+00 9.35E+00 1.19E+02 0.00E+00 1.42E+02 4.58E+00 5.53E+03 Tc-11 0.001E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 Ru-103 1.02E+03 0.OOE+00 4.39E+02 0.00E+00 3.88E+03 0.OOE+00 1.19E+05 Ru-105 8.51E-04 0.00E+00 3.36E-04 0.00E+00 1.10E-02 0.00E+00 5.20E-01 Ru-106 2.04E+04 0.00E+00 2.58E+03 0.00E+00 3.94E+04 0.OOE+00 1.32E+06 Ag-IIOM 5.82E+07 5.39E+07 3.20E+07 0.OOE+00 1.06E+08 0.00E+00 2.20E+10 Page 11.4-45

CY-BY-1 70-301 Revision 8 Table 4-16 (Continued)

Adult Grass-Cow-Milk Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lune GI-LLI Te-125M 1.63E+07 5.91E+06 2.18E+06 4.90E+06 6.63E+07 0.00E+00 6.51E+07 Te-127M 4.58E+07 1.64E+07 5.58E+06 1.17E+07 1.86E+08 0.00E+00 1.54E+08 Te-127 6.66E+02 2.39E+02 1.44E+02 4.94E+02 2.71E+03 0.00E+00 5.26E+04 Te-129M 6.02E+07 2.24E+07 9.52E+06 2.07E+07 2.51E+08 0.00E+00 3.03E+08 Te-129 2.8313-10 1.06E-10 6.88E-11 2.17E-10 1.19E-09 0.00E+00 2.13E-10 Te-131M 3.61 E+05 1.76E+05 1.47E+05 2.79E+05 1.79E+06 0.00E+00 1.75E+07 Te-131 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+0O 0.00E+00 0.001E+00 0.00E+00 Te-132 2.39E+06 1.55E+06 1.45E+06 1.71E+06 1.49E+07 0.00E+00 7.32E+07 1-130 4.18E+05 1.23E+06 4.86E+05 1.04E+08 1.92E+06 0.00E+00 1.06E+06 1-131 12.96E+08 4.23E+08 2.43E+08 1.39E+11 7.26E+08 0.00E+00 1.12E+08 1-132 1.65E-01 4.40E-01 1.54E-01 1.54E+01 7.02E-01 0.00E+00 8.27E-02 1-133 3.88E+06 6.74E+06 2.06E+06 9.91E+08 1.18E+07 0.00E+00 6.06E+06 1-134 1.89E-12 5.13E-12 1.83E-12 8.89E-11 8.16E-120.001E+00 4.47E-15 1-135 1.29E+04 3.38E+04 1.2513+04 2.23E+06 5.42E+04 0.00E+00 3.82E+04 Cs-134 5.65E+09 1.35E+10 1.10E+10 0.00E+00 4.35E+09 1.45E+09 2.35E+08 Cs-136 2.63E+08 1.04E+09 7.46E+08 0.00E+00 5.77E+08 7.91E+07 1.18E+08 Cs-137 7.38E+09 1.01E+10 6.61E+09 0.00E+00 3.43E+09 1.14E+09 1.95E+08 Cs-138 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 Ba-139 4.43E-08 3.1613-11 1.30E-090.00E+00 2.95E-11 1.79E-11 7.86E-08 Ba-140 2.69E+07 3.38E+04 1.76E+06 0.00E+00 1.15E+04 1.93E+04 5.54E+07 Ba-141 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Ba-142 0.00E+00 0.00E+00 0.003E+00 0.00E+00 0.OOE+00 0.001E+00 O.00E+00 La-140 4.52E+00 2.28E+00 6.0213-01 0.001E+00 0.00E+00 0.00E+00 1.67E+05 La-142 1.89E-11 8.59E-12 2.14E-12 0.00E+00 0.00E+00 0.00E+00 6.28E-08 Ce-141 4.84E+03 3.28E+03 3.72E+02 0.003E+00 1.52E+03 0.00E+00 1.25E+07 Ce-143 4.15E+01 3.07E+04 3.39E+00 0.00E+00 1.35E+01 0.00E+00 1.15E+06 Ce-144 3.58E+05 1.50E+05 1.92E+04 0.00E+00 8.87E+04 0.00E+00 1.211E+08 Pr-143 1.58E+02 6.34E+01 7.83E+00 0.00E+00 3.66E+01 0.0013+00 6.92E+05 Pr-144 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Nd-147 9.48E+01 1.10E+02 6.5613+00 0.00E+00 6.41E+01 0.00E+00 5.26E+05 W-187 6.511E+03 5.44E+03 1.90E+03 0.00E1+00 0.00E+00 0.00E+00 1.78E+06 Np-239 3.67E+00 3.61E-01 1.99E-01 0.003E+00 1.12E+00 0.0013+00 7.401+04 Notes:

1) 2)

Units are m 2 mrem/yr per gCi/sec.

For H-3 and C-14, the units are mremn/yr per tCi/m3.

Page 11.4-46

CY-BY-1 70-301 Revision 8 Table 4-17 Teen Grass-Cow-Milk Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lun2 GI-LLI H-3 0.00E+00 5.66E+02 5.66E+02 5.66E+02 5.66E+02 5.66E1+02 5.66E+02 C-14 6.70E+05 1.34E+05 1.34E+05 1.34E+05 1.34E+05 1.34E+05 1.34E+05 Na-24 4.29E+06 4.29E+06 4.29E+06 4.29E+06 4.29E+06 4.29E+06 4.29E+06 Cr-51 0.00E+00 0.OOE+00 4.99E+04 2.77E+04 1.09E+04 7.12E+04 8.38E+06 Mn-54 0.OOE+00 1.40E+07 2.78E+06 0.OOE+00 4.18E+06 0.OOE+00 2.87E+07 Mn-56 0.OOE+00 7.32E-03 1.30E-03 0.00E+00 9.27E-03 0.00E+00 4.82E-01 Fe-55 4.45E+07 3.16E+07 7.36E+06 0.00E+00 0.00E+00 2.OOE+07 1.37E+07 Fe-59 5.18E+07 1.211E+08 4.67E+07 0.00E+00 0.00E+00 3.811E+07 2.86E+08 Co-58 0.OOE+00 7.94E+06 1.83E+07 0.00E+00 0.OOE+00 0.OOE+00 1.09E+08 Co-60 0.00E+00 2.78E+07 6.26E+07 0.00E+00 0.00E+00 0.00E+00 3.62E+08 Ni-63 1.18E+10 8.35E+08 4.01E+08 0.00E+00 0.OOE+00 0.00E+00 1.33E+08 Ni-65 6.78E-01 8.66E-02 3.94E-02 0.00E+00 0.OOE+00 0.OOE+00 4.70E+00 Cu-64 0.00E+00 4.211E+04 1.98E+040.OOE+00 1.06E+05 0.00E+00 3.26E+06 Zn-65 2.111E+09 7.31E+09 3.41E+090.001E+0014.68E+09 0.00E+00 3.10E+09 Zn-69 3.70E-12 7.05E-12 4.94E-13 0.00E+00 4.61E-12 0.00E+00 1.30E-11 Br-83 0.00E+00 0.00E+00 1.78E-01 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Br-84 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 Br-85 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.003E+00 0.00E+00 Rb-86 0.00E+00 4.73E+09 2.22E+09 0.00E+00 0.00E+00 0.00E+00 7.0 1E+08 Rb-88 0.00E+00 0.00E+000.001E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Rb-89 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Sr-89 2.67E+09 0.00E+00 7.66E+07 0.00E+00 0.00E+00 0.00E+00 3.18E+08 Sr-90 8.13E+10 0.00E+00 1.63E+09 0.00E+00 0.00E+00 0.00E+00 1.86E+09 Sr-91 5.27E+04 0.00E+00 2.101E+03 0.00E+00 0.00E+00 0.00E+00 2.39E+05 Sr-92 8.85E-01 0.001E+00 3.77E-02 0.00E+00 0.00E+00 0.OOE+00 2.26E+01 Y-90 1.30E+02 0.00E+00 3.5 1 E+00 0.00E+00 0.00E+00 0.00E+00 1.08E+06 Y-91M 1.18E-19 0.00E+000.001E+00 0.00E+00 0.00E+00 0.OOE+00 5.55E-18 Y-91 1.58E+04 0.00E+00 4.24E+02 0.00E+00 0.00E+0 0.001E+00 6.48E+06 Y-92 1.03E-04 0.00E+00 2.98E-06 0.00E+00 0.00E+00 0.00E+00 2.82E+00 Y-93 4.09E-01 0.00E+00 1. 12E-02 0.00E+0010.00E+00 0.00E+00 1.25E+04 Zr-95 1.65E+03 5.21E+02 3.58E+02 0.00E+00 7.65E+02 0.00E+00 1.20E+06 Zr-97 7.87E-01 1.56E-01 7.17E-02 0.00E+00 2.36E-01 0.00E+00 4.22E+04 Nb-95 1.41E+05 7.82E+04 4.30E+04 0.00E+00 7.58E+04 0.00E+00 3.34E+08 Mo-99 0.00E+00 4.46E+07 8.511E+06 0.00E+00 1.02E+08 0.00E+00 8.00E+07 Tc-99M 5.74E+00 1.60E+01 2.07E+02 0.00E+00 2.39E+02 8.89E+00 1.05E+04 Tc-101 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Ru-103 1.81E+03 0.00E+00 7.74E+02 0.003E+006.38E+03 0.00E+00 1.51E+05 Ru-105 1.55E-03 0.00E+00 6.03E-04 0.00E+00 1.96E-02 0.00E+00 1.25E+00 Ru-106 3.75E+04 0.00E+00 4.73E+03 0.00E+00 7.24E+04 0.00E+00 1.80E+06 Ag-110M 9.63E+07 9.111E+07 5.54E+07 0.00E+00 1.74E+08 0.00E+00 2.56E+10 Page 11.4-47

CY-BY-1 70-301 Revision 8 Table 4-17 (Continued)

Teen Grass-Cow-Milk Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-125M 3.01E+07 1.08E+07 4.02E+06 8.40E+06 O.OOE+00 0.OOE+00 8.87E+07 Te-127M 8.44E+07 2.99E+07 1.OOE+07 2.O1E+07 3.42E+08 0.OOE+00 2.10E+08 Te-127 1.24E+03 4.38E+02 2.66E+02 8.52E+02 5.OOE+03 0.OOE+00 9.54E+04 Te-129M 1.1OE+08 4.09E+07 1.74E+07 3.55E+07 4.61E+08 0.OOE+00 4.13E+08 Te-129 5.20E-10 1.94E-10 1.27E-10 3.72E-10 2.18E-09 0.OOE+00 2.84E-09 Te-131M 6.57E+05 3.15E+05 2.63E+05 4.74E+05 3.28E+06 0.OOE+00 2.53E+07 Te-131 0.OOE+O0 0.OOE+00 0.OOE+O0 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+0C Te-132 4.27E+06 2.7 1 E+06 2.55E+06 2.85E+06 2.60E+07 0.OOE+00 8.57E+07 1-130 7.35E+05 2.13E+06 8.49E+05 1.73E+08 3.27E+06 0.OOE+00 1.63E+06 1-131 5.37E+08 7.52E+08 4.04E+08 2.19E+1 1 1.29E+09 O.OOE+00 1.49E+08 1-132 2.92E-01 7.64E-01 2.74E-01 2.57E+01 1.20E+00 0.OOE+O0 3.33E-01 1-133 7.08E+06 1.20E+07 3.66E+06 1.68E+09 2.11E+07 O.OOE+00 9.09E+06 1-134 3.35E-12 8.89E-12 3.19E-12 1.48E-10 1.40E-1 0.OOE+00 1.17E-13 1-135 2.29E+04 5.91E1+04 2.19E+04 3.80E+06 9.33E+04 0.OOE+00 6.54E+04 Cs-134 9.82E+09 2.31E+10 1.07E+10 0.OOE+00 7.34E+09 2.80E+09 2.87E+08 Cs-136 4.47E+08 1.76E+09 1.18E+09 O.OOE+00 9.58E+08 1.51E E+08 1.42E+08 Cs-137 1.34E+10 1.78E+10 6.20E+09 0.00E+00 6.06E+09 2.35E+09 2.53E+08 Cs-138 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+0O Ba-139 8.20E-08 5.77E-11 2.39E-09 0.OOE+00 5.44E-11 3.98E-11 7.31E-07 Ba-140 4.85E+07 5.95E+04 3.13E+06 O.OOE+00 2.02E+04 4.OOE+04 7.49E+07 Ba-141 0.00E+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 Ba-142 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 La-140 8.12E+00 3.99E+00 1.06E+00 0.OOE+00 O.OOE+00 O.OOE+00 2.29E+05 La-142 3.41E-11 1.51E-11 3.77E-12 0.OOE+00 0.OOE+00 0.OOE+00 4.61E-07 Ce-141 8.88E+03 5.93E+03 6.81E+02 O.OOE+00 2.79E+03 O.OOE+00 1.70E+07 Ce-143 7.62E+01 5.55E+04 6.20E+00 0.OOE+00 2.49E+O1 0.OOE+00 1.67E+06 Ce-144 6.58E+05 2.72E+05 3.54E+04 0.OOE+00 1.63E+05 0.OOE+00 1.66E+08 Pr-143 2.90E+02 1.16E+02 1.44E+01 0.OOE+00 6.74E+01 0.OOE+00 9.55E+05 Pr-144 0.00E+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 Nd-147 1.82E+02 1.98E+02 1.19E+O1 O.OOE+00 1.17E+02 0.OOE+00 7.16E+05 W-187 1.19E+04 9.71E+03 3.40E+03 0.OOE+00 0.OOE+0 0.O0E+00 2.63 E+06 Np-239 7.001E+001 6.60E-01 3.67E-01 O.OOE+00 2.07E+00 0.OOE+00 1.06E+05 Notes:

1) 2)

Units are m2 mrem/yr per g.Ci/sec.

For H-3 and C-14, the units are mrem/yr per JiCi/m3.

Page 11.4-48

CY-BY-1 70-301 Revision 8 Table 4-18 Child Grass-Cow-Milk Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI H-3 O.OOE+00 8.97E+02 8.97E+02 8.97E+02 8.97E+02 8.97E+02 8.97E+02 C-14 1.65E+06 3.29E+05 3.29E+05 3.29E+05 3.29E+05 3.29E+05 3.29E+05 Na-24 8.93E+06 8.93E+06 8.93E+06 8.93E+06 8.93E+06 8.93E+06 8.93E+06 Cr-51 O.OOE+00 O.OOE+O0 1.02E+05 5.65E+04 1.54E+04:1.03E+05 5.39E+06 Mn-54 0.00E+00 2.10E+07 5.59E+06 O.OOE+00 5.88E+06 O.OOE+00 1.76E+07 Mn-56 O.OOE+00 1.28E-02 2.88E-03 O.OOE+00 1.54E-02 O.OOE+00 1.85E+00 Fe-55 1.12E+08 5.93E+07 1.84E+07 O.OOE+00 O.OOE+00 3.35E+07 1.1OE+07 Fe-59 1.20E+08 1.94E+08 9.69E+07 O.OOE+00 0.OOE+00 5.64E+07 2.02E+08 Co-58 O.OOE+00 1.21E+07 3.71E+07 O.OOE+00 O.OOE+00 O.OOE+00 7.08E+07 Co-60 O.OOE+00 4.32E+07 1.27E+08 O.OOE+00 O.OOE+00 O.OOE+00 2.39E+08 Ni-63 2.96E+10 1.59E+09 1.OIE+09 O.OOE+00 O.OOE+00 O.OOE+00 1.07E+08 Ni-65 1.66E+00 1.56E-01 9.11E-02 O.OOE+00 O.OOE+00 O.OOE+00 1.91E+01 Cu-64 O.OOE+O0 7.39E+04 4.47E+04 O.OOE+00 1.79E+05 0.OOE+00 3.47E+06 Zn-65 4.13E+09 1.1OE+10 6.85E+09 O.OOE+00 6.94E+09 O.OOE+00 1.93E+09 Zn-69 9.1OE-12 1.32E-11 1.22E-12 O.OOE+00 7.98E-12 O.OOE+00 8.29E-10 Br-83 O.OOE+00 O.OOE+00 4.37E-01 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-84 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-85 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 Rb-86 O.OOE+00 8.78E+09 5.40E+09 O.OOE+00 O.OOE+00 O.OOE+00 5.65E+08 Rb-88 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-89 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Sr-89 6.62E+09 O.OOE+00 1.89E+08 O.OOE+00 O.OOE+00 O.OOE+00 2.56E+08 Sr-90 1.68E+1 I O.OOE+00 3.3 8E+09 O.OOE+00 O.OOE+00 O.OOE+00 1.5 1E+09 Sr-91 1.29E+05 O.OOE+00 4.88E+03 O.OOE+00 O.OOE+00 O.OOE+00 2.86E+05 Sr-92 2.16E+00 O.OOE+00 8.67E-02 O.OOE+00 O.OOE+00 O.OOE+00 4.09E+O1 Y-90 3.23E+02 O.OOE+00 8.64E+00 O.OOE+00 O.OOE+00 O.OOE+00 9.19E+05 Y-91M 2.87E-19 O.OOE+00 1.04E-20 O.OOE+00 0.OOE+00 O.OOE+00 5.62E-16 Y-91 3.90E+04 O.OOE+00 1.04E+03 O.OOE+00 O.OOE+00 O.OOE+00 5.20E+06 Y-92 2.53E-04 O.OOE+00 7.23E-06 O.OOE+00 O.OOE+00 O.OOE+00 7.30E+00 Y-93 1.OOE+00 O.OOE+00 2.75E-02 O.OOE+00 O.OOE+00 O.OOE+00 1.50E+04 Zr-95 3.83E+03 8.43E+02 7.50E+02 O.OOE+00 1.21E+03 O.OOE+00 8.79E+05 Zr-97 1.91E+00 2.77E-01 1.63E-01 O.OOE+00 3.97E-01 O.OOE+00 4.19E+04 Nb-95 3.18E+05 1.24E+05 8.85E+04 O.OOE+00 1.16E+05 O.OOE+00 2.29E+08 Mo-99 O.OOE+00 8.12E+07 2.0IE+07 O.OOE+00 1.73E+08 O.OOE+00 6.72E+07 Tc-99M 1.32E+01 2.58E+01 4.28E+02 O.OOE+00 3.75E+02 1.31E+01 1.47E+04 Tc-101 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Ru-103 4.28E+03 O.OOE+00 1.65E+03 O.OOE+00 1.08E+04 O.OOE+00 1.1 IE+05 Ru-105 3.79E-03 O.OOE+00 1.38E-03 O.OOE+00 3.33E-02 O.00E+00 2.48E+00 Ru-106 9.24E+04 O.OOE+00 1.15E+04 O.OOE+00 1.25E+05 O.OOE+00 1.44E+06 Ag-I1OM 2.09E+08 1.41E+08 1.13E+08 0.OOE+00 2.63E+08 O.OOE+00 1.68E+10 Page 11.4-49

CY-BY-170-301 Revision 8 Table 4-18 (Continued)

Child Grass-Cow-Milk Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-125M 7.38E+07 2.00E+07 9.84E+06 2.0713+07 0.0013+00 0.00E-+00 7.12E+07 Te-127M 2.08E+08 5.60E+07 2.47E+07 4.97E+07 5.93E+08 0.OOE+00 1.68E+08 Te-127 3.04E+03 8.1913+02 6.5 11E+02 2.103E+03 8.64E+03 0.OOE+00 1.19E+05 Te-129M 2.7 1E+08 7.58E+07 4.21E+07 8.75E+07 7.97E+08 0.00E+00 3.3 IE+08 Te-129 1.28E-09 3.58E-10 3.05E-10 9.16E-10 3.75E-09 0.00E+00 7.99E-08 Te-131M 1.60E+06 5.53E+05 5.88E+05 1.14E+06 5.35E+06 0.00E+00 2.24E+07 Te-131 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Te-132 1.02E+07 4.52E+06 5.46E+06 6.58E+06 4.19E+07 0.00E+00 4.55E+07 1-130 1.72E+06 3.47E+06 1.79E+06 3.82E+08 5.19E+06 0.00E+00 1.62E+06 1-131 11.30E+09 1.311E+09 7.45E+08 4.33E+11 2.15E+09 0.00E+00 1.17E+08 1-132 6.91E-01 1.27E+00 5.84E-01 5.89E+01 1.94E+00 0.OOE+00 1.49E+00 1-133 1.72E+07 2.13E+07 8.05E+06 3.95E+09 3.55E+07 0.OOE+00 8.57E+06 1-134 7.94E-12 1.47E-11 6.79E-12 3.39E-10 2.26E-11 O.OOE+00 9.78E-12 1-135 5.43E+04 9.78E+04 4.62E+04 8.66E+06 1.50E+05 0.OOE+00 7.45E+04 Cs-134 2.26E+10 3.72E+10 7.84E+09 0.00E+00 1.15E+10 4.13E+09 2.OOE+08 Cs-136 1.01E+09 2.77E+09 1.80E+09 0.00E+00 1.48E+09 2.20E+08 9.75E+07 Cs-137 3.22E+10 3.09E+10 4.55E+09 0.OOE+00 I.01E+10 3.62E+09 1.93E+08 Cs-138 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Ba-139 2.01E-07 1.08E-10 5.84E-09 0.OOE+00 9.39E-11 6.33E-11 1.16E-05 Ba-140 1.17E+08 1.03E+05 6.84E+06 0.OOE+00 3.34E+04 6.12E+04 5.94E+07 Ba-141 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 Ba-142 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 La-140 11.95E+01 6.80E+00 2.29E+00 0.00E+00 0.OOE+00 0.OOE+00 1.90E+05 La-142 8.24E-I1 2.63E-I1 8.22E-12 0.00E+00 0.00E+00 0.00E+00 5.20E-06 Ce-141 2.19E+04 1.09E+04 1.62E+03 0.OOE+00 4.78E+03 0.OOE+00 1.36E+07 Ce-143 1.87E+02 1.01E+05 1.47E+01 0.00E+O0 4.26E+01 0.OOE+00 1.49E+06 Ce-144 1.62E+06 5.09E+05 8.66E+04 0.00E+00 2.82E+05 0.00E+00 1.33E+08 Pr-143 7.18E+02 2.16E+02 3.57E+01 0.OOE+00 1.17E+02 0.OOE+00 7.75E+05 Pr-144 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 Nd-147 4.48E+02 3.63E+02 2.81E+01 O.OOE+00 1.99E+02 0.00E+00 5.75E+05 W-187 2.89E+04 1.71E+04 7.67E+03 0.00E+00 0.OOE+00 0.00E+00 2.40E+06 Np-239 1.72E+01 1.24E+00 8.69E-01 0.00E+00 3.58E+00 0.OOE+00 9.15E+04 Notes:

1) 2)

Units are m2 mrem/yr per giCi/sec.

For H-3 and C-14, the units are mrem/yr per jiCi/m3.

Page 11.4-50

CY-BY-170-301 Revision 8 Table 4-19 Infant Grass-Cow-Milk Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI H-3 O.OOE+00 1.36E+03 1.36E+03 1.36E+03 1.36E+03 1.36E+03 1.36E+03 C-14 3.23E+06 6.89E+05 6.89E+05 6.89E+05 6.89E+05 6.89E+05 6.89E+05 Na-24 1.56E+07 1.56E+07 1.56E+07 1.56E+07 1.56E+07 1.56E+07 1.56E+07 Cr-51 O.OOE+00 O.OOE+00 1.61E+05 1.05E+05 2.30E+04 2.05E+05 4.70E+06 Mn-54 0.00E+00 3.90E+07 8.84E+06 O.OOE+00 8.64E+06 O.OOE+O0 1.43E+07 Mn-56 O.OOE+00 3.13E-02 5.39E-03 O.OOE+00 2.69E-02 O.OOE+00 2.84E+00 Fe-55 1.35E+08 8.73E+07 2.33E+07 O.OOE+00 O.OOE+00 4.27E+07 1.1 1E+07 Fe-59 2.24E+08 3.92E+08 1.54E+08 O.OOE+00 O.OOE+00 1.16E+08 1.87E+08 Co-58 O.OOE+00 2.43E+07 6.05E+07 O.OOE+00 O.OOE+00 O.OOE+00 6.04E+07 Co-60 O.OOE+00 8.82E+07 2.08E+08 O.OOE+00 0.OOE+00 O.OOE+00 2.10E+08 Ni-63 3.49E+10 2.16E+09 1.21E+09 O.OOE+00 O.OOE+00 O.OOE+00 1.07E+08 Ni-65 3.51E+00 3.97E-01 1.81E-01 O.OOE+00 O.OOE+00 O.OOE+00 3.02E+01 Cu-64 O.OOE+00 1.84E+05 8.5 1E+04 O.OOE+00 3.11 E+05 O.OOE+00 3.77E+06 Zn-65 5.55E+09 1.90E+10 8.78E+09 O.OOE+00 9.23E+09 O.OOE+00 1.61E+10 Zn-69 1.94E-11 3.49E-11 2.60E-12 O.OOE+00 1.45E-11 O.OOE+00 2.85E-09 Br-83 O.OOE+00 O.OOE+00 9.27E-01 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-84 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-85 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 Rb-86 O.OOE+00 2.23E+10 1.1OE+10 O.OOE+00 O.OOE+00 O.OOE+00 5.70E+08 Rb-88 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-89 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Sr-89 1.26E+10 O.OOE+00 3.61E+08 O.OOE+00 O.OOE+00 O.OOE+00 2.59E+08 Sr-90 1.86E+1 1 O.OOE+00 3.77E+09 O.OOE+00 O.OOE+00 O.OOE+00 1.52E+09 Sr-91 2.70E+05 O.OOE+00 9.76E+03 O.OOE+00 0.OOE+00 O.OOE+00 3.19E+05 Sr-92 4.60E+00 O.OOE+00 1.7 1E-01 O.OOE+00 O.OOE+00 O.OOE+00 4.96E+O1 Y-90 6.82E+02 O.OOE+00 1.83E+01 O.OOE+00 O.OOE+00 O.OOE+00 9.42E+05 Y-91M 6.09E-19 O.OOE+00 2.07E-20 O.OOE+00 O.OOE+00 O.OOE+00 2.03E-15 Y-91 7.33E+04 O.OOE+00 1.95E+03 O.OOE+00 O.OOE+00 O.OOE+00 5.25E+06 Y-92 5.37E-04 O.OOE+00 1.5 IE-05 O.OOE+00 0.OOE+00 O.OOE+00 1.02E+01 Y-93 2.14E+00 O.OOE+00 5.83E-02 O.OOE+00 O.OOE+00 O.OOE+00 1.69E+04 Zr-95 6.8 1E+03 1.66E+03 1.18E+03 O.OOE+00 1.79E+03 O.OOE+00 8.26E+05 Zr-97 4.05E+00 6.96E-01 3.18E-01 O.OOE+00 7.01E-01 O.OOE+00 4.44E+04 Nb-95 5.94E+05 2.45E+05 1.41E+05 O.OOE+00 1.75E+05 O.OOE+00 2.07E+08 Mo-99 O.OOE+00 2.08E+08 4.05E+07 O.OOE+00 3.IOE+08 O.OOE+00 6.84E+07 Tc-99M 2.74E+01 5.65E+01 7.27E+02 O.OOE+00 6.08E+02 2.95E+01 1.64E+04 Tc-101 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Ru-103 8.67E+03 O.OOE+00 2.90E+03 O.OOE+00 1.80E+04 0.OOE+00 i.05E+05 Ru-105 8.OOE-03 O.OOE+00 2.69E-03 O.OOE+O0 5.88E-02 O.OOE+00 3.18E+00 Ru-106 1.90E+05 O.OOE+00 2.38E+04 O.OOE+00 2.25E+05 O.OOE+00 1.44E+06 Ag-I IOM 3.86E+08 2.82E+08 1.86E+08 O.OOE+00 4.03E+08 O.OOE+00 1.46E+10 Page 11.4-51

CY-BY-1 70-301 Revision 8 Table 4-19 (Continued)

Infant Grass-Cow-Milk Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-125M 1.51E+08 5.04E+07 2.04E+07 5.08E+07 0.OOE+00 O.OOE+00 7.19E+07 Te-127M 4.21E+08 1.40E+08 5.10OE+07 1.22E+08 1.04E+09 0.OOE+00 1.70E+08 Te-127 6.45E+03 2.16E+03 1.39E+03 5.25E+03 1.57E+04 0.OOE+00 1.35E+05 Te-129M 5.57E+08 1.91E+08 8.58E+07 2.14E+08 1.39E+09 0.OOE+00 3.33E+08 Te-129 2.72E-09 9.38E-10 6.35E-10 2.28E-09 6.77E-09 0.OOE+00 2.17E-07 Te-131M 3.37E+06 1.36E+06 1.12E+06 2.75E+06 9.35E+06 O.OOE+00 2.29E+07 Te-131 O.OOE+00 O.OOE+00 O.OOE+0 0.003E+00 0.OOE+00 O.OOE+00 0.OOE+00 Te-132 2.1OE+07 1.04E+07 9.71E+06 1.54E+07 6.5 1EE+07 O.OOE+00 3.85E+07 1-130 3.53E+06 7.77E+06 3.12E+06 8.71EE+08 8.53E+06 O.OOE+00 1.67E+06 1-131 2.72E+09 3.20E+09 1.41E+09 1.05E+12 3.74E+09 O.OOE+00 1.14E+08 1-132 1.43E+00 2.91E+00 1.04E+00 1.36E+02 3.25E+00 O.OOE+00 2.36E+00 1-133 3.63E+07 5.29E+07 1.55E+07 9.62E+09 6.22E+07 O.OOE+00 8.95E+06 1-134 1.65E-11 3.37E-11 1.20E-11 7.87E-10 3.77E-11 0.OOE+00 3.49E-11 1-135 1.13E+05 2.25E+05 8.19E+04 2.01E+07 2.50E+05 O.OOE+00 8.13E+04 Cs-134 3.65E+10 6.80E+10 6.87E+09 0.OOE+00 1.75E+10 7.18E+09 1.85E+08 Cs-136 1.97E+09 5.80E+09 2.16E+09 O.OOE+00 2.3 1E+09 4.72E+08 8.80E+07 Cs-137 5.15E+10 6.02E+10 4.27E+09 O.OOE+00 1.62E+10 6.55E+09 1.88E+08 Cs-138 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Ba-139 4.29E-07 2.84E-10 1.24E-08 0.OOE+00 1.71E-10 1.72E-10 2.72E-05 Ba-140 2.41E+08 2.41E+05 1.24E+07 0.OOE+00 5.72E+04 1.48E+05 5.92E+07 Ba-141 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 Ba-142 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 La-140 4.06E+01 1.60E+01 4.12E+00 O.OOE+00 O.OOE+00 O.OOE+00 1.88E+05 La-142 1.73E-10 6.35E-11 1.52E-11 0.OOE+00 0.OOE+00 O.OOE+00 1.08E-05 Ce-141 4.34E+04 2.64E+04 3.11E+03 0.OOE+00 8.15E+03 0.OOE+00 1.37E+07 Ce-143 3.96E+02 2.63E+05 3.OOE+01 0.OOE+00 7.65E+01 O.OOE+00 1.53E+06 Ce-144 2.33E+06 9.52E+05 1.30E+05 O.OOE+00 3.85E+05 O.OOE+00 1.33E+08 Pr-143 1.49E+03 5.56E+02 7.37E+01 O.OOE+00 2.07E+02 O.OOE+00 7.84E+05 Pr-144 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Nd-147 8.88E+02 9.12E+02 5.59E+01 O.OOE+00 3.51E+02 0.OOE+00 5.78E+05 W-187 6.08E+04 4.23E+04 1.46E+04 0.OOE+00 0.OOE+00 O.OOE+00 2.48E+06 Np-239 3.64E+01 3.26E+00 1.84E+00 0.OOE+00 6.50E+00 0.OOE+00 9.42E+04 Notes:

1) 2)

Units are m2 mrem/yr per gCi/sec.

For H-3 and C-14, the units are mrem/yr per pCi/m3.

Page 11.4-52

CY-BY-1 70-301 Revision 8 Table 4-20 Adult Grass-Goat-Milk Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Luna GI-LLI H-3 O.OOE+00 8.88E+02 8.88E+02 8.88E+02 8.88E+02 8.88E+02 8.88E+02 C-14 3.63E+05 7.26E+04 7.26E+04 7.26E+04 7.26E+04 7.26E+04 7.26E+04 Na-24 2.95E+05 2.95E+05 2.95E+05 2.95E+05 2.95E+05 2.95E+05 2.95E+05 Cr-51 O.OOE+00 0.OOE+00 3.43E+03 2.05E+03 7.55E+02 4.55E+03 8.62E+05 Mn-54 O.OOE+00 1.01E+06 1.93E+05 0.OOE+0013.OOE+05 0.OOE+00 3.09E+06 Mn-56 O.OOE+00 4.95E-04 8.79E-05 O.OOE+00 6.29E-04 O.OOE+00 1.58E-02 Fe-55 3.26E+05 2.26E+05 5.26E+04 O.OOE+00 0.OOE+00 1.26E+05 1.29E+05 Fe-59 3.86E+05 9.07E+05 3.48E+05 0.OOE+00 O.OOE+00 2.53E+05 3.02E+06 Co-58 0.OOE+00 5.66E+05 1.27E+06 0.OOE+00 0.OOE+00 O.OOE+00 1.15E+07 Co-60 0.OOE+00 1.97E+06 4.34E+06 0.OOE+00 O.OOE+00 0.OOE+00 3.70E+07 Ni-63 8.07E+08 5.60E+07 2.7 1E+07 0.OOE+00 O.OOE+00 0.OOE+00 1.17E+07 Ni-65 4.44E-02 5.77E-03 2.63E-03 0.OOE+00 O.OOE+00 0.OOE+00 1.46E-01 Cu-64 0.OOE+00 2.63E+03 1.23E+03 0.OOE+00 6.63E+03 0.OOE+00 2.24E+05 Zn-65 1.65E+08 5.24E+08 2.37E+08 0.OOE+00 3.50E+08 0.OOE+00 3.30E+08 Zn-69 2.41E-13 4.61E-13 3.21E-14 O.OOE+00 3.OOE-13 0.OOE+00 6.93E-14 Br-83 0.OOE+00 O.OOE+00 1. 16E-02 O.OOE+00 O.OOE+00 0.OOE+00 1.67E-02 Br-84 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 Br-85 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 Rb-86 O.OOE+00 3.12E+08 1.45E+08 0.OOE+00 0.OOE+00 O.OOE+00 6.15E+07 Rb-88 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-89 0.OOE+0 0.OOE+00 0.OOE+0O 0.OOE+00 0.OOE+0O 0.OOE+0O 0.OOE+00 Sr-89 3.05E+09 O.OOE+00 8.74E+07 O.OOE+0O10.OOE+00 0.OOE+00 4.88E+08 Sr-90

1. 13E+1 1 0.OOE+0O 2.27E+09 O.OOE+0 O.OOE+0 0.OOE+00 2.84E+09 Sr-91 6.03E+04 O.OOE+00 2.44E+03 0.OOE+0O 0.OOE+00 O.OOE+00 2.87E+05 Sr-92 1.02E+00 O.OOE+00 4.39E-02 0.OOE+00 0.OOE+00 O.OOE+00 2.01E+01 Y-90 8.52E+0 0.OOE+00 2.28E-01 O.OOE+00 0.OOE+00 0.OOE+00 9.03E+04 Y-91M 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 2.26E-20 Y-91 1.03E+03 O.OOE+00 2.76E+01 O.OOE+00 O.OOE+00 0.OOE+00 5.67E+05 Y-92 6.68E-06 0.OOE+00 1.95E-07 0.OOE+0O 0.OOE+00 0.OOE+00 1.17E-01 Y-93 2.66E-02 0.OOE+0O 7.34E-04 0.OOE+00 0.OOE+00 0.OOE+00 8.43E+02 Zr-95 1.13E+02 3.63E+01 2.46E+01 O.OOE+00 5.70E+01 0.OOE+00 1.15E+05 Zr-97 5.19E-02 1.05E-02 4.79E-03 0.OOE+00 1.58E-02 0.OOE+00 3.24E+03 Nb-95 9.92E+03 5.52E+03 2.97E+03 O.OOE+00 5.45E+03 O.OOE+00 3.35E+07 Mo-99 0.OOE+00 2.97E+06 5.65E+05 O.OOE+00 6.72E+06 O.OOE+00 6.88E+06 Tc-99M 3.97E-01 1.12E+00 1.43E+01 0.OOE+00 1.70E+01 5.50E-01 6.64E+02 Tc-101 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Ru-103 1.22E+02 0.OOE+00 5.26E+01 0.OOE+00 4.66E+02 0.OOE+00 1.43E+04 Ru-105 1.02E-04 O.OOE+00 4.03E-05 O.OOE+00 1.32E-03 O.OOE+00 6.25E-02 Ru-106 2.45E+03 O.OOE+00 3.10E+02 O.OOE+00 4.73E+03 0.OOE+00 1.58E+05 Ag-110M 6.99E+06 6.46E+06 3.84E+06 0.OOE+00 1.27E+07 0.OOE+00 2.64E+09 Page 11.4-53

CY-BY-1 70-301 Revision 8 Table 4-20 (Continued)

Adult Grass-Goat-Milk Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-125M 1.96E+06 7.09E+05 2.62E+05 5.88E+05 7.95E+06 0.OOE+00 7.81E+06 Te-127M 5.49E+06 1.96E+06 6.69E+05 1.40E+06 2.23E+07 0.OOE+00 1.84E+07 Te-127 8.OOE+01 2.87E+01 1.73E+01 5.92E+01 3.26E+02 0.OOE+00 6.31E+03 Te-129M 7.22E+06 2.69E+06 1.14E+06 2.48E+06 3.01E+07 O.OOE+00 3.64E+07 Te-129 3.39E-11 1.27E-11 8.26E-12 2.60E-11 1.43E-100.OOE+00 2.56E-11 Te-131M 4.33E+04 2.12E+04 1.76E+04 3.35E+04 2.14E+05 O.OOE+00 2.10E+06 Te-131 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 Te-132 2.87E+05 1.86E+05 1.74E+05 2.05E+05 1.79E+06 O.OOE+00 8.78E+06 1-130 5.01E+05 1.48E+06 5.84E+05 1.25E+08 2.31E+06 0.OOE+00 1.27E+06 1-131 3.55E+08 5.08E+08 2.9 1E+08 1.67E+11 8.7 1EE+08 O.OOE+00 1.34E+08 1-132 1.98E-01 5.29E-01 1.85E-01 1.85E+01 8.42E-01 O.OOE+00 9.93E-02 1-133 4.65E+06 8.09E+06 2.47E+06 1.19E+09 1.41E+07 O.OOE+0O 7.27E+06 1-134 2.27E-12 6.15E-12 2.20E-12 1.07E-10 9.79E-12 0.OOE+00 5.36E-15 1-135 1.55E1+04 4.06E+04 1.50E+04 2.68E+06 6.51E+04 0.OOE+00 4.58E+04 Cs-134 1.70E+10 4.04E+10 3.30E+10 O.OOE+00 1.31E+10 4.34E+09 7.06E+08 Cs-136 7.88E+08 3.1 1E+09 2.24E+09 0.OOE+00 1.73E+09 2.37E+08 3.53E+08 Cs-137 2.21E+10 3.03E+10 1.98E+10 O.OOE+00 1.03E+10 3.42E+09 5.86E+08 Cs-138 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 Ba-139 5.32E-09 3.79E-12 1.56E-10 0.OOE+00 3.54E-12 2.15E-12 9.44E-09 Ba-140 3.23E+06 4.05E+03 2.11E+05 0.OOE+00 1.38E+03 2.32E+03 6.64E+06 Ba-141 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 0.OOE+00 Ba-142 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 La-140 5.43E-01 2.74E-01 7.23E-02 0.OOE+00 0.OOE+00 O.OOE+00 2.01E+04 La-142 2.27E-12 1.03E-12 2.57E-13 O.OOE+0O 0.OOE+00 O.OOE+00 7.53E-09 Ce-141 5.81E+02 3.93E+02 4.46E+01 O.OOE+00 1.83E+02 O.OOE+00 1.50E+06 Ce-143 4.98E+00 3.68E+03 4.07E-01 O.OOE+00 1.62E+00 O.OOE+00 1.38E+05 Ce-144 4.29E+04 1.79E+04 2.30E+03 O.OOE+00 1.06E+04 0.OOE+00 1.45E+07 Pr-143 1.90E+01 7.60E+00 9.40E-01 0.OOE+00 4.39E+00 O.OOE+00 8.3 1E+04 Pr-144 0.00E+00 0.OOE+00 0.OOE+00 O.OOE+0 0.OOE+00 O.OOE+0O 0.OOE+00 Nd-147 1.14E+01 1.32E+01 7.87E-01 0.OOE+00 7.69E+00 O.OOE+00 6.31E+04 W-187 7.82E+02 6.53E+02 2.28E+02 0.OOE+00 0.00E+00 0.00E+O0 2.14E+05 Np-239 4.40E-01 4.33E-02 2.39E-02 0.OOE+00 1.35E-01 0.OOE+00 8.88E+03 Notes:

1) 2)

Units are m2 mrem/yr per ptCi/sec.

For H-3 and C-14, the units are mrem/yr per jtCi/m3.

Page 11.4-54

CY-BY-170-301 Revision 8 Table 4-21 Teen Grass-Goat-Milk Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI H-3 0.OOE+00 1.16E+03 1.16E+03 1.16E+03 1.16E+03 1.16E-+03 1.16E+03 C-14 6.70E+05 1.34E+05 1.34E+05 1.34E+05 1.34E+05 1.34E+05 1.34E+05 Na-24 5.15E+05 5.15E+05 5.15E+05 5.15E+05 5.15E+05 5.15E+05 5.15E+05 Cr-51 O.OOE+00 0.OOE+00 5.99E+03 3.33E+03 1.31E+03 8.55E+03 1.O0E+06 Mn-54 O.OOE+00 1.68E+06 3.34E+05 O.OOE+00 5.02E+05 O.OOE+00 3.45E+06 Mn-56 O.OOE+00 8.78E-04 1.56E-04 0.OOE+00 1.1 IE-03 0.OOE+00 5.78E-02 Fe-55 5.79E+05 4.1 LE+05 9.57E+04 0.OOE+00 O.OOE+00 2.60E+05 1.78E+05 Fe-59 6.74E+05 1.57E+06 6.07E+05 O.OOE+00 0.OOE+00 4.96E+05 3.72E+06 Co-58 0.OOE+00 9.53E+05 2.20E+06 0.OOE+0O O.OOE+00 0.OOE+00 1.3 1E+07 Co-60 0.OOE+00 3.34E+06 7.52E+06 O.OOE+00 O.OOE+00 0.OOE+00 4.35E+07 Ni-63 1.42E+09 1.OOE+08 4.81E+07 O.OOE+00 0.OOE+00 O.OOE+00 1.59E+07 Ni-65 8.13E-02 1.04E-02 4.73E-03 O.OOE+00 O.OOE+00 O.OOE+00 5.63E-01 Cu-64 0.OOE+00 4.69E+03 2.20E+03 0.OOE+00 1. 19E+04 0.OOE+00 3.64E+05 Zn-65 2.53E+08 8.78E+08 4.09E+08 O.OOE+00 5.62E+08 O.OOE+00 3.72E+08 Zn-69 4.44E-13 8.46E-13 5.92E-14 O.OOE+00 5.53E-13 0.OOE+00 1.56E-12 Br-83 O.OOE+00 O.OOE+00 2.13E-02 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 Br-84 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 Br-85 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 Rb-86 O.OOE+00 5.68E+08 2.67E+08 O.OOE+00 0.OOE+00 0.OOE+00 8.41E+07 Rb-88 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+0 0.OOE+00 0.OOE+00 0.OOE+00 Rb-89 O.OOE+00 0.OOE+0 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Sr-89 5.61E+09 0.OOE+00 1.61E+08 0.OOE+00 O.OOE+00 O.OOE+0 6.69E+08 Sr-90 1.71E+ 1 0.OOE+00 3.4 1E+09 0.OOE+00 0.OOE+00 O.OOE+00 3.90E+09 Sr-91 1.11E+05 O.OOE+00 4.41E+03 0.OOE+00 O.OOE+00 O.OOE+00 5.02E+05 Sr-92 1.86E+0O 0.OOE+00 7.92E-02 0.OOE+00 0.OOE+00 0.OOE+00 4.74E+O 1 Y-90 1.56E+01 O.OOE+00 4.21E-01 0.OOE+00 O.OOE+00 0.OOE+00 1.29E+05 Y-91M 1.41E-20 0.OOE+0O 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 6.66E-19 Y-91 1.90E+03 O.OOE+00 5.08E+01 0.OOE+00 0.OOE+00 O.OOE+00 7.77E+05 Y-92 1.23E-05 0.OOE+0 3.57E-07 O.OOE+00 O.OOE+00 O.OOE+00 3.39E-01 Y-93 4.90E-02 O.OOE+00 1.34E-03 0.OOE+00 0.OOE+00 0.OOE+00 1.50E+03 Zr-95 1.98E+02 6.25E+01 4.30E+01 0.OOE+00 9.18E+01 0.OOE+00 1.44E+05 Zr-97 9.44E-02 1.87E-02 8.61E-03 O.OOE+00 2.83E-02 O.OOE+00 5.06E+03 Nb-95 1.69E+04 9.38E+03 5.16E+03 O.OOE+00 9.09E+03 O.OOE+00 4.01E+07 Mo-99 O.OOE+00 5.36E+06 1.02E+06 O.OOE+00 l.23E+07 O.OOE+00 9.59E+06 Tc-99M 6.89E-01 1.92E+00 2.49E+01 O.OOE+00 2.86E+01 1.07E+00 1.26E+03 Tc-101 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 Ru-103 2.17E+02 0.OOE+00 9.29E+01 O.OOE+00 7.66E+02 0.OOE+00 1.81E+04 Ru-105 1.86E-04 O.OOE+00 7.24E-05 O.OOE+00 2.35E-03 O.OOE+00 1.51E-01 Ru-106 4.50E+03 O.OOE-K)0 5.67E+02 0.OOE+00 8.68E+03 O.OOE+00 2.16E+05 Ag-110M 1.16E+07 1.09E+07 6.65E+06 0.OOE+00 2.09E+07 0.OOE+00 3.07E+09 Page 11.4-55

CY-BY-170-301 Revision 8 Table 4-21 (Continued)

Teen Grass-Goat-Milk Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-125M 3.61E+06 1.30E+06 4.82E+05 1.OIE+06 0.00E+00 O.00E+00 1.06E+07 Te-127M 1.0 IE+07 3.59E+06 1.20E+06 2.41E+06 4.10E+07 O.OOE+00 2.52E+07 Te-127 1.48E+02 5.25E+01 3.19E+01 1.02E+02 6.OOE+02 0.00E+00 1.14E+04 Te-129M 1.32E+07 4.90E+06 2.09E+06 4.26E+06 5.53E+07 0.00E+00 4.96E+07 Te-129 6.24E-11 2.33E-11 1.52E-11 4.46E-11 2.62E-100.OOE+00 3.41E-10 Te-131M 7.88E+04 3.78E+04 3.15E+04 5.68E+04 3.94E+05 0.00E+00 3.03E+06 Te-131 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Te-132 5.13E+05 3.25E+05 3.06E+05 3.42E+05 3.12E+06 0.00E+00 1.03E+07 1-130 8.82E+05 2.55E+06 1.02E+06 2.08E+08 3.93E+06 0.00E+00 1.96E+06 1-131 6.45E+08 9.02E+08 4.85E+08 2.63E+ 11 1.55E+09 0.00E+00 1.78E+08 1-132 3.50E-01 9.17E-01 3.29E-01 3.09E+01 1.44E+00 0.00E+00 3.99E-01 1-133 8.50E+06 1.44E+07 4.40E+06 2.01E+09 2.53E+07 0.00E+00 1.09E+07 1-134 4.03E-12 1.07E-11 3.83E-12 1.78E-10 1.68E-11 0.00E+00 1.41E-13 1-135 2.75E+04 7.09E+04 2.63E+04 4.56E+06 1.12E+05 0.00E+00 7.85E+04 Cs-134 2.94E+10 6.93E+10 3.22E+10 0.00E+00 2.20E+10 8.41E+09 8.62E+08 Cs-136 1.34E+09 5.28E+09 3.54E+09 0.00E+00 2.87E+09 4.53E+08 4.25E+08 Cs-137 4.02E+10 5.34E+10 1.86E+10 0.00E+00 1.8213+10 7.06E+09 7.60E+08 Cs-138 0.00E+00 0.00E+00 0.00E+00 0.00E+0010.00E+00 0.00E+00 0.00E+00 Ba-139 9.84E-09 6.92E-12 2.87E-10 0.00E+00 6.53E-12 4.77E-12 8.78E-08 Ba-140 5.82E+06 7.14E+03 3.75E+05 0.00E+00 2.42E+03 4.80E+03 8.98E+06 Ba-141 0.001E+00 0.001+00.OOE+00 0.001+000.001E+00 0.00E+00 0.00E+00 Ba-142 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 La-140 9.75E-01 4.79E-01 1.27E-01 0.00E+00 0.00E+00 0.00E+00 2.75E+04 La-142 4.09E-12 1.82E-12 4.53E-13 0.00E+00 0.OOE+00 0.00E+00 5.53E-08 Ce-141 1.07E+03 7.12E+02 8.17E+01 0.00E+00 3.35E+02 0.00E+00 2.04E+06 Ce-143 9.15E+00 6.66E+03 7.44E-01 0.001E+00 2.99E+00 0.OOE+00 2.OOE+05 Ce-144 7.90E+04 3.27E+04 4.24E+03 0.00E+00 1.95E+04 0.00E+00 1.99E+07 Pr-143 3.48E+01 1.39E+01 1.73E+00 0.00E+00 8.08E+00 0.00E+00 1.15E+05 Pr-144 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Nd-147 2.19E+01 2.38E+01 1.43E+00 0.00E+00 1.40E+01 0.00E+00 8.59E+04 W-187 1.43E+03 1.17E+03 4.08E+02 0.00E+000.001+00 0.001E+00 3.15E+05 Np-239 8.40E-01 7.921E-02 4.401-02 0.003+00 2.49-01 0.001E+00 1.27E+04 Notes:

1) 2)

Units are m2 mrem/yr per tCi/sec.

For H-3 and C-14, the units are mrem/yr per pCi/m3.

Page 11.4-56

CY-BY-1 70-301 Revision 8 Table 4-22 Child Grass-Goat-Milk Dose Factors Nuclide Bone Liver T Bod, Thyroid Kidney Lung GI-LLI H-3 O.OOE+00 1.83E+03 1.83E+03 1.83E+03 1.83E+03 1.83E+03 1.83E+03 C-14 1.65E+06 3.29E+05 3.29E+05 3.29E+05 3.29E+05 3.29E+05 3.29E+05 Na-24 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 Cr-51 O.OOE+00 O.OOE+00 1.22E+04 6.78E+03 1.85E+03 1.24E+04 6.47E+05 Mn-54 0.OOE+00 2.52E+06 6.70E+05 O.OOE+00 7.06E+05 O.OOE+00 2.1 1E+06 Mn-56 O.OOE+00 1.53E-03 3.46E-04 O.OOE+00 1.85E-03 O.OOE+00 2.22E-01 Fe-55 1.45E+06 7.71E+05 2.39E+05 O.OOE+00 O.OOE+00 4.36E+05 1.43E+05 Fe-59 1.56E+06 2.53E+06 1.26E+06 O.OOE+00 O.OOE+00 7.33E+05 2.63E+06 Co-58 O.OOE+00 1.46E+06 4.46E+06 O.OOE+00 O.OOE+00 O.OOE+00 8.49E+06 Co-60 0.OOE+00 5.18E+06 1.53E+07 O.OOE+00 O.OOE+00 O.OOE+00 2.87E+07 Ni-63 3.56E+09 1.90E+08 1.21E+08 O.OOE+00 0.OOE+00 O.OOE+O0 1.28E+07 Ni-65 1.99E-01 1.87E-02 1.09E-02 O.OOE+00 O.OOE+00 O.OOE+00 2.29E+00 Cu-64 O.OOE+00 8.24E+03 4.98E+03 O.OOE+00 1.99E+04 0.OOE+00 3.87E+05 Zn-65 4.96E+08 1.32E+09 8.22E+08 O.OOE+00 8.33E+08 O.OOE+00 2.32E+08 Zn-69 1.09E-12 1.58E-12 1.46E-13 0.OOE+00 9.57E-13 0.OOE+00 9.95E-11 Br-83 O.OOE+00 O.OOE+00 5.24E-02 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+0O Br-84 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+0(O Br-85 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+OO Rb-86 0.OOE+00 1.05E+09 6.48E+08 O.OOE+00 O.OOE+00 O.OOE+00 6.78E+07 Rb-88 O.OOE+00 O.00E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-89 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Sr-89 1.39E+10 O.OOE+00 3.97E+08 O.OOE+00 O.OOE+00 O.OOE+00 5.38E+08 Sr-90 3.53E+1 1 O.OOE+00 7.11 E+09 O.OOE+00 O.OOE+00 O.OOE+00 3.16E+09 Sr-91 2.72E+05 O.OOE+00 1.03E+04 O.OOE+00 O.OOE+00 O.OOE+00 6.OOE+05 Sr-92 4.54E+00 O.OOE+00 1.82E-01 O.OOE+00 O.OOE+00 O.OOE+00 8.60E+01 Y-90 3.87E+O1 O.OOE+00 1.04E+00 O.OOE+0( O.OOE+00 O.OOE+00 1.1OE+05 Y-91M 3.45E-20 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 6.75E-17 Y-91 4.68E+03 O.OOE+00 1.25E+02 O.OOE+00 O.OOE+0 O.OOE+00 6.24E+05 Y-92 3.03E-05 O.OOE+00 8.67E-07 O.OOE+00 O.OOE+00 O.OOE+00 8.75E-01 Y-93 1.20E-01 O.OOE+00 3.31E-03 O.OOE+00 O.OOE+00 O.OOE+00 1.80E+03 Zr-95 4.60E+02 1.OlE+02 9.OOE+01 O.OOE+00 1.45E+02 O.OOE+00 1.05E+05 Zr-97 2.30E-01 3.32E-02 1.96E-02 O.OOE+00 4.77E-02 O.OOE+0O 5.03E+03 Nb-95 3.82E+04 1.49E+04 1.06E+04 O.OOE+00 1.40E+04 O.OOE+00 2.75E+07 Mo-99 O.OOE+00 9.75E+06 2.41E+06 O.OOE+00 2.08E+07 O.OOE+00 8.06E+06 Tc-99M 1.58E+00 3.10E+00 5.14E+01 O.OOE+00 4.50E+01 1.57E+00 1.76E+03 Tc-101 O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Ru-103 15.14E+02 O.OOE+O0 1.97E+02 O.OOE+O0 1.29E+03 O.OOE+00 1.33E+04 Ru-105 4.55E-04 O.OOE+00 1.65E-04 O.OOE+00 4.OOE-03 O.OOE+00 2.97E-01 Ru-106 1.1 IE+04 O.OOE+00 1.38E+03 O.OOE+00 1.50E+04 O.OOE+00 1.72E+05 Ag-IIOM 2.51E+07 1.69E+07 1.35E+07 O.OOE+00 3.15E+07 O.OOE+00 2.01E+09 Page 11.4-57

CY-BY-170-301 Revision 8 Table 4-22 (Continued)

Child Grass-Goat-Milk Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-125M 8.86E+06 2.40E+06 1.18E+06 2.49E+06 0.00E+00.OOE+0O0 8.55E+06 Te-127M 2.50E+07 6.72E+06 2.96E+06 5.97E+06 7.12E+07 0.OOE+00 2.02E+07 Te-127 3.64E+02 9.83E+01 7.82E+01 2.52E+02 1.04E+03 0.OOE+00 1.42E+04 Te-129M 3.26E+07 9.09E+06 5.05E+06 1.05E+07 9.56E+07 0.OOE+00 3.97E+07 Te-129 1.54E-10 4.30E-l1 3.66E-11 1.1OE-10 4.51E-100.OOE+00 9.59E-09 Te-131M 1.92E+05 6.63E+04 7.06E+04 1.36E+05 6.42E+05 0.OOE+00 2.69E+06 Te-131 O.OOE+0O 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.O0E+00 Te-132 1.22E+06 5.42E+05 6.55E+05 7.89E+05 5.03E+06 0.OOE+00 5.46E+06 1-130 2.06E+06 4.17E+06 2.15E+06 4.59E+08 6.23E+06 0.OOE+00 1.95E+06 1-131 1.56E+09 1.57E+09 8.94E+08 5.20E+11 2.58E+09 O.OOE+00 1.40E+08 1-132 8.29E-01 1.52E+00 7.OOE-01 7.07E+01 2.33E+00 0.OOE+00 1.79E+00 1-133 2.06E+07 2.55E+07 9.66E+06 4.74E+09 4.25E+07 O.OOE+00 1.03E+07 1-134 9.53E-12 1.77E-11 8.14E-12 4.07E-10 2.71E-11 0.OOE+00 1.17E-11 1-135 6.52E+04 1.17E+05 5.55E+04 1.04E+07 1.80E+05 0.OOE+00 8.94E+04 Cs-134 6.79E+10 1.1 IE+I I 2.35E+10 0.OOE+O0 3.45E+10 1.24E+10 6.01EE+08 Cs-136 13.03E+09 8.32E+09 5.39E+09 0.OOE+00 4.43E+09 6.61E+08 2.92E+08 Cs-137 9.67E+10 9.26E+10 1.37E+10 0.OOE+00 3.02E+10 1.09E+10 5.80E+08 Cs-138 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 Ba-139 2.42E-08 1.29E-11 7.OIE-100.OOE+00 1.13E-11 7.59E-12 1.40E-06 Ba-140 1.41E+07 1.23E+04 8.21E+05 O.OOE+00 4.01E+03 7.34E+03 7.12E+06 Ba-141 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.00E+00 Ba-142 O.OOE+00 O.OOE+00 O.OOE+00O0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 La-140 2.33E+00 8.16E-01 2.75E-01 O.OOE+00 0.OOE+00 0.OOE+00 2.27E+04 La-142 9.88E-12 3.15E-12 9.87E-13 O.OOE+00 0.OOE+00 O.OOE+00 6.24E-07 Ce-141 2.62E+03 1.31E+03 1.94E+02 0.00E+00 5.74E+02 0.OOE+00 1.63E+06 Ce-143 2.25E+01 1.22E+04 1.76E+00 0.OOE+0O 5.1IE+00 0.OOE+00 1.78E+05 Ce-144 1.95E+05 6.11E+04 1.04E+04 O.OOE+00 3.38E+04 O.OOE+00 1.59E+07 Pr-143 8.62E+01 2.59E+01 4.28E+00 0.OOE+00 1.40E+01 O.OOE+00 9.30E+04 Pr-144 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+O0 O.OOE+00 0.OOE+00 O.OOE+00 Nd-147 5.37E+01 4.35E+01 3.37E+00 0.OOE+00 2.39E+01 0.OOE+00 6.89E+04 W-187 3.47E+03 2.05E+03 9.2 IE+02 0.OOE+00 0.OOE+00 0.OOE+00 2.88E+05 Np-239 2.07E+00 1.48E-01 1.04E-01 O.OOE+00 4.29E-01 0.OOE+O0 1.IOE+04 Notes:

1) 2)

Units are m2 mrem/yr per ICi/sec.

For H-3 and C-14, the units are mrem/yr per tCi/m3.

Page 11.4-58

CY-BY-1 70-301 Revision 8 Table 4-23 Infant Grass-Goat-Milk Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI H-3 O.OOE+00 2.78E+03 2.78E+03 2.78E+03 2.78E+03 2.78E+03 2.78E+03 C-14 3.23E+06 6.89E+05 6.89E+05 6.89E+05 6.89E+05 6.89E+05 6.89E+05 Na-24 1.87E+06 1.87E+06 1.87E+06 1.87E+06 1.87E+06 1.87E+06 1.87E+06 Cr-51 O.OOE+00 O.OOE+00 1.93E+04 1.26E+04 2.76E+03 2.46E+04 5.64E+05 Mn-54 0.OOE+00 4.68E+06 1.06E+06 O.OOE+00 1.04E+06 O.OOE+00 1.72E+06 Mn-56 O.OOE+00 3.75E-03 6.47E-04 O.OOE+00 3.22E-03 O.OOE+00 3.41E-01 Fe-55 1.76E+06 1.13E+06 3.03E+05 O.OOE+00 O.OOE+00 5.55E+05 1.44E+05 Fe-59 2.92E+06 5.09E+06 2.01E+06 O.OOE+00 O.OOE+00 1.51E+06 2.43E+06 Co-58 O.OOE+00 2.9 1E+06 7.26E+06 O.OOE+00 O.OOE+00 O.OOE+00 7.25E+06 Co-60 O.OOE+00 1.06E+07 2.50E+07 O.OOE+00 O.OOE+00 O.OOE+00 2.52E+07 Ni-63 4.19E+09 2.59E+08 1.45E+08 O.OOE+00 O.OOE+00 0.00E+00 1.29E+07 Ni-65 4.21E-01 4.77E-02 2.17E-02 0.OOE+00 0.OOE+00 0.OOE+00 3.63E+00 Cu-64 O.OOE+00 2.05E+04 9.48E+03 O.OOE+00 3.46E+04 O.OOE+00 4.20E+05 Zn-65 6.66E+08 2.28E+09 1.05E+09 O.OOE+00 1.1IE+09 O.OOE+00 1.93E+09 Zn-69 2.33E-12 4.19E-12 3.12E-13 O.OOE+00 1.74E-12 O.OOE+00 3.42E-10 Br-83 O.OOE+O0 0.OOE+00 1.11E-01 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Br-84 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 Br-85 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 Rb-86 O.OOE+00 2.67E+09 1.32E+09 O.OOE+00 O.OOE+00 O.OOE+00 6.84E+07 Rb-88 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-89 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+0 0.OOE+00 O.OOE+0O O.OOE+00 Sr-89 2.64E+10 O.OOE+00 7.58E+08 O.OOE+00 O.OOE+00 O.OOE+00 5.43E+08 Sr-90 3.91E+1 1 O.OOE+00 7.92E+09 O.OOE+00 O.OOE+00 O.OOE+00 3.19E+09 Sr-91 5.66E+05 O.OOE+00 2.05E+04 O.OOE+00 O.OOE+00 O.OOE+00 6.70E+05 Sr-92 9.65E+00 O.OOE+00 3.59E-01 O.OOE+00 O.OOE+00 O.OOE+00 1.04E+02 Y-90 8.19E+O l O.OOE+00 2.20E+00 O.OOE+00 O.OOE+00 O.OOE+00 1.13 E+05 Y-91M 7.3 1E-20 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 2.44E-16 Y-91 8.79E+03 O.OOE+00 2.34E+02 O.OOE+00 O.OOE+00 O.OOE+00 6.30E+05 Y-92 6.44E-05 O.00E+00 1.81E-06 O.OOE+00 O.OOE+00 O.OOE+O0 1.23E+00 Y-93 2.57E-01 O.OOE+00 6.99E-03 O.OOE+00 O.OOE+00 O.OOE+O0 2.03E+03 Zr-95 8.17E+02 1.99E+02 1.41E+02 O.OOE+00 2.15E+02 O.OOE+00 9.91E+04 Zr-97 4.87E-01 8.35E-02 3.81E-02 0.OOE+00 8.42E-02 0.OOE+00 5.33E+03 Nb-95 7.13E+04 2.94E+04 1.70E+04 O.OOE+00 2.IOE+04 O.0OE+00 2.48E+07 Mo-99 O.OOE+00 2.49E+07 4.86E+06 O.OOE+00 3.72E+07 O.OOE+00 8.21E+06 Tc-99M 3.29E+00 6.78E+00 8.73E+01 O.OOE+00 7.29E+01 3.54E+00 1.97E+03 Tc-101 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 Ru-103 1.04E+03 O.OOE+00 3.48E+02 O.OOE+00 2.16E+03 O.OOE+00 1.27E+04 Ru-105 9.60E-04 O.OOE+00 3.23E-04 0.00E+00 7.06E-03 O.OOE+00 3.82E-01 Ru-106 2.28E+04 O.OOE+00 2.85E+03 O.OOE+00 2.70E+04 O.OOE+00 1.73E+05 Ag-110M 4.63E+07 3.38E+07 2.24E+07 O.OOE+00 4.84E+07 O.OOE+00 1.75E+09 Page 11.4-59

CY-BY-170-301 Revision 8 Table 4-23 (Continued)

Infant Grass-Goat-Milk Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-125M 1.81E+07 6.05E+06 2.45E+06 6.09E+06 0.00E+00 0.00E+00 8.6213+06 Te-127M 5.05E+07 1.68E+07 6.12E+06 1.46E+07 1.24E+08 0.00E+00 2.04E+07 Te-127 7.74E+02 2.59E+02 1.66E+02 6.30E+02 1.89E+03 0.00E+00 1.63E+04 Te-129M 6.68E+07 2.29E+07 1.03E+07 2.57E+07 1.67E+08 0.OOE+00 3.99E+07 Te-129 3.26E-10 1.13E-10 7.62E-11 2.74E-10 8.13E-100.00E+00 2.61E-08 Te-131M 4.05E+05 1.63E+05 1.35E+05 3.30E+05 1.12E+06 0.00E+00 2.74E+06 Te-131 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+0O 0.OOE+00 Te-132 2.52E+06 1.25E+06 1.17E+06 1.84E+06 7.8 IE+06 0.OOE+00 4.62E+06 1-130 4.24E+06 9.32E+06 3.74E+06 1.04E+09 1.02E+07 0.OOE+00 2.00E+06 1-131 3.26E+09 3.85E+09 1.69E+09 1.26E+12 4.49E+09 0.OOE+00 1.37E+08 1-132 1.72E+0130 3.49E+00 1.24E+00 1.64E+02 3.90E+00 0.00E+00 2.83E+00 1-133 4.36E+07 6.35E+07 1.86E+07 1.15E+10 7.46E+07 0.00E+00 1.07E+07 1-134 1.98E-11 4.05E-11 1.44E-11 9.44E-10 4.53E-11 0.00E+00 4.19E-11 1-135 1.36E+05 2.70E+05 9.83E+04 2.42E+07 3.01E+05 0.00E+00 9.76E+04 Cs-134 1.09E+11 2.04E+11 2.06E+10 0.OOE+00 5.25E+10 2.15E+10 5.54E+08 Cs-136 5.91E+09 1.74E+10 6.49E+09 0.OOE+00 6.93E+09 1.42E+09 2.64E+08 Cs-137 1.54E+11 1.81E+l1 1.28E+10 0.OOE+00 4.85E+10 1.96E+10 5.65E+08 Cs-138 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.001E+00 0.00E+00 Ba-139 5.1413-08 3.41E-11 1.49E-090.00E+00 2.05E-11 2.07E-11 3.26E-06 Ba-140 2.89E+07 2.89E+04 1.49E+06 0.00E+00 6.87E+03 1.78E+04 7.111E+06 Ba-141 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+0010.00E+00 0.00E+00 0.00E+00 Ba-142 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 La-140 4.88E+00 1.92E+00 4.95E-01 0.00E+00 0.00E+00 0.00E+00 2.26E+04 La-142 2.08E-11 7.62E-12 1.82E-120.00E+000.00E+000.00E+00 1.29E-06 Ce-141 5.20E+03 3.17E+03 3.73E+02 0.OOE+00 9.78E+02 0.00E+00 1.64E+06 Ce-143 4.75E+01 3.15E+04 3.60E+00 0.00E+00 9.19E+00 0.00E+00 1.84E+05 Ce-144 2.79E+05 1.14E+05 1.56E+04 0.00E+00 4.62E+04 0.00E+00 1.60E+07 Pr-143 1.78E+02 6.67E+01 8.84E+00 0.00E+00 2.48E+01 0.00E+00 9.41E+04 Pr-144 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 Nd-147 1.07E+02 1.09E+02 6.70E+00 0.OOE+00 4.22E+01 0.00E+00 6.93E+04 W-187 7.29E+03 5.07E+03 1.75E+03 0.OOE+00 0.00E+00 0.00E+00 2.98E+05 Np-239 4.37E+00 3.91E-01 2.21E-01 0.00E+00 7.80E-01 0.00E+00 1.13E+04 Notes:

1) 2)

Units are m2 mrern/yr per gCi/sec.

For H-3 and C-14, the units are mren/yr per tCi/m3.

Page 11.4-60

CY-BY-1 70-301 Revision 8 Table 4-24 Adult Grass-Cow-Meat Dose Factors Nuclide Bone Liver T Body Thyroid Kidnev Lunp-GI-LLI H-3 0.OOE+00 1.85E+02 1.85E+02 1.85E+02 1.85E+02 1.85E+02 1.85E+02 C-14 3.33E+05 6.66E+04 6.66E+04 6.66E+04 6.66E+04 6.66E+04 6.66E+04 Na-24 1.45E-03 1.45E-03 1.45E-03 1.45E-03 1.45E-03 1.45E-03 1.45E-03 Cr-51 O.OOE+00 O.OOE+00 7.04E+03 4.21E+03 1.55E+03 9.34E+03 1.77E+06 Mn-54 0.OOE+00 9.18E+06 1.75E+06 O.OOE+00 2.73E+06 O.OOE+00 2.81E+07 Mn-56 0.OOE+0O 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+0O Fe-55 2.93E+08 2.03E+08 4.72E+07 0.OOE+00 0.OOE+00 1.13E+08 1.16E+08 Fe-59 2.65E+08 6.24E+08 2.39E+08 O.OOE+00 0.OOE+00 1.74E+08 2.08E+09 Co-58 0.OOE+00 1.82E+07 4.09E+07 0.OOE+00 O.OOE+00 0.OOE+00 3.70E+08 Co-60 O.OOE+00 7.52E+07 1.66E+08 0.OOE+00 O.OOE+00 0.OOE+00 1.41E+09 Ni-63 1.89E+10 1.3 LE+09 6.33E+08 O.OOE+00 O.OOE+00 O.OOE+00 2.73E+08 Ni-65 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 Cu-64 O.OOE+00 2.52E-07 1.18E-07 O.OOE+00 6.36E-07 0.OOE+00 2.15E-05 Zn-65 3.56E+08 1.13E+09 5.12E+08 0.OOE+00 7.57E+08 0.OOE+00 7.13E+08 Zn-69 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 Br-83 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Br-84 0.OOE+0O 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-85 O.OOE+0O 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-86 0.OOE+00 4.88E+08 2.28E+08 O.OOE+00 O.OOE+00 O.OOE+00 9.63E+07 Rb-88 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 Rb-89 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 Sr-89 3.01E+08 0.OOE+00 8.65E+06 O.OOE+00 O.OOE+00 0.OOE+00 4.83E+07 Sr-90 1.43E+10 0.OOE+00 2.87E+08 0.OOE+00 O.OOE+00 O.OOE+00 3.59E+08 Sr-91 1.43E-10 O.OOE+00 5.79E-12 O.OOE+00 0.OOE+00 O.OOE+00 6.83E-10 Sr-92 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+0O 0.OOE+00 Y-90 1.08E+02 O.OOE+00 2.91E+00 0.OOE+00 0.OOE+00 0.OOE+00 1.15E+06 Y-91M 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Y-91 1.13E+06 O.OOE+00 3.03E+04 0.OOE+00 0.OOE+0O O.OOE+00 6.23E+08 Y-92 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+0O 0.OOE+00 0.OOE+00 Y-93 4.39E-12 0.OOE+00 1.21E-13 O.OOE+00 O.OOE+00 0.OOE+00 1.39E-07 Zr-95 1.87E+06 6.01E+05 4.07E+05 O.OOE+00 9.43E+05 O.OOE+O0 1.91E+09 Zr-97 2.04E-05 4.12E-06 1.88E-06 0.OOE+00 6.22E-06 O.OOE+00 1.28E+00 Nb-95 2.30E+06 1.28E+06 6.89E+05 0.OOE+00 1.27E+06 0.OOE+00 7.78E+09 Mo-99 0.OOE+00 9.93E+04 1.89E+04 O.OOE+00 2.25E+05 0.OOE+00 2.30E+05 Tc-99M 0.OOE+00 1.22E-20 1.56E-19 O.OOE+00 1.85E-19 O.OOE+00 7.23E-18 Tc-101 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 Ru-103 1.05E+08 0.OOE+00 4.53E+07 O.OOE+00 4.01E+08 O.OOE+00 1.23E+10 Ru-105 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 Ru-106 2.80E+09 O.OOE+00 3.54E+08 0.OOE+00 5.40E+09 0.OOE+00 1.8 1E+I 1 Ag-110M 6.68E+06 6.18E+06 3.67E+06 0.OOE+00 1.22E+07 0.OOE+00 2.52E+09 Page 11.4-61

CY-BY-1 70-301 Revision 8 Table 4-24 (Continued)

Adult Grass-Cow-Meat Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lunu GI-LLI Te-125M 3.59E+08 1.30E+08 4.81E+07 1.08E+08 1.46E+09 0.OOE+00 1.43E+09 Te-127M 1.12E+09 3.99E+08 1.36E+08 2.85E+08 4.53E+09 O.OOE+00 3.74E+09 Te-127 2.50E-10 8.98E-11 5.41E-11 1.85E-10 1.02E-090.OOE+00 1.97E-08 Te-129M 1.13E+09 4.23E+08 1.79E+08 3.89E+08 4.73E+09 0.OOE+00 5.7 lE+09 Te-129 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+0O 0.OOE+00 0.OOE+00 Te-131M 4.49E+02 2.20E+02 1.83E+02 3.48E+02 2.23E+03 O.OOE+00 2.18E+04 Te-131 O.OOE+00 O.OOE+0 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Te-132 1.40E+06 9.03E+05 8.48E+05 9.98E+05 8.70E+06 O.OOE+00 4.27E+07 1-130 2.03E-06 5.98E-06 2.36E-06 5.07E-04 9.33E-06 O.OOE+00 5.15E-06 1-131 1.07E+07 1.54E+07 8.80E+06 5.03E+09 2.63E+07 0.OOE+00 4.05E+06 1-132 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 1-133 3.70E-01 6.43E-01 1.96E-01 9.45E+01 1.12E+00 0.OOE+00 5.78E-01 1-134 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 1-135 4.66E-17 1.22E-16 4.50E-17 8.04E-15 1.95E-16 O.OOE+00 1.38E-16 Cs-134 6.58E+08 1.57E+09 1.28E+09 0.OOE+00 5.07E+08 1.68E+08 2.74E+07 Cs-136 1.20E+07 4.73E+07 3.40E+07 0.OOE+00 2.63E+07 3.61E+06 5.37E+06 Cs-137 8.72E+08 1.19E+09 7.81E+08 0.OOE+00 4.05E+08 1.35E+08 2.31E+07 Cs-138 O.OOE+00 O.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 Ba-139 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 Ba-140 2.88E+07 3.611E+04 1.88E+06 0.OOE+00 1.23E+04 2.07E+04 5.92E+07 Ba-141 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 Ba-142 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 La-140 3.76E-02 1.90E-02 5.01E-03 0.OOE+00 0.OOE+00 O.OOE+00 1.39E+03 La-142 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 Ce-141 1.40E+04 9.49E+03 1.08E+03 O.OOE+00 4.41E+03 0.OOE+00 3.63E+07 Ce-143 1.99E-02 1.47E+01 1.63E-03 0.OOE+00 6.47E-03 O.OOE+00 5.49E+02 Ce-144 1.46E+06 6.09E+05 7.83E+04 0.OOE+00 3.61E+05 O.OOE+00 4.93E+08 Pr-143 2.IOE+04 8.42E+03 1.04E+03 O.OOE+00 4.86E+03 0.OOE+00 9.20E+07 Pr-144 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 Nd-147 7.21E+03 8.33E+03 4.98E+02 0.OOE+00 4.87E+03 O.OOE+00 4.OOE+07 W-187 2.07E-02 1.73E-02 6.04E-03 0.OOE+00 O.OOE+00 0.OOE+00 5.66E+00 Np-239 2.57E-01 2.53E-02 1.40E-02 0.OOE+00 7.90E-02 0.OOE+00 5.19E+03 Notes:

1) 2)

Units are m2 mrem/yr per gCi/sec.

For H-3 and C-14, the units are mren/yr per tCi/m3.

Page 11.4-62

CY-BY-1 70-301 Revision 8 Table 4-25 Teen Grass-Cow-Meat Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI H-3 O.OOE+00 1.1OE+02 1.10E+)02 1.1OE+02 1.10E*02 1.1OE+02 1.1OE+02 C-14 2.81E+05 5.62E+04 5.62E+04 5.62E+04 5.62E+04 5.62E+04 5.62E+04 Na-24 1.16E-03 1.16E-03 1.16E-03 1.16E-03 1.16E-03 1.16E-03 1.16E-03 Cr-51 O.OOE+00 O.OOE+00 5.63E+03 3.13E+03 1.23E+03 8.04E+03 9.46E+05 Mn-54 0.OOE+00 7.OOE+06 1.39E+06 O.OOE+00 2.09E+06 O.OOE+00 1.44E+07 Mn-56 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+0O Fe-55 2.38E+08 1.69E+08 3.94E+07 O.OOE+00 O.OOE+00 1.07E+08 7.3 1E+07 Fe-59 2.12E+08 4.95E+08 1.91E+08 O.OOE+00 O.OOE+00 1.56E+08 1.17E+09 Co-58 0.00E+00 1.41E+07 3.24E+07 O.OOE+00 O.OOE+00 O.OOE+00 1.94E+08 Co-60 O.OOE+00 5.83E+07 1.3 IE+08 O.OOE+00 O.OOE+00 O.OOE+00 7.60E+08 Ni-63 1.52E+10 1.07E+09 5.15E+08 O.OOE+00 O.OOE+00 O.OOE+00 1.71E+08 Ni-65 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Cu-64 0.00E+00 2.06E-07 9.68E-08 O.OOE+00 5.2 IE-07 O.OOE+00 1.60E-05 Zn-65 2.50E+08 8.69E+08 4.05E+08 O.OOE+00 5.56E+08 O.OOE+00 3.68E+08 Zn-69 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-83 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-84 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-85 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 Rb-86 O.OOE+00 4.08E+08 1.91E+08 O.OOE+00 O.OOE+00 O.OOE+00 6.03E+07 Rb-88 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-89 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Sr-89 2.54E+08 O.OOE+00 7.28E+06 O.OOE+00 0.OOE+00 O.OOE+00 3.03E+07 Sr-90 9.89E+09 O.OOE+00 1.98E+08 O.OOE+00 O.OOE+00 O.OOE+00 2.26E+08 Sr-91 1.21E-10 O.OOE+00 4.80E-12 O.OOE+00 O.OOE+00 O.OOE+00 5.47E-10 Sr-92 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Y-90 9.13E+O1 O.OOE+00 2.46E+00 O.OOE+00 O.OOE+00 O.OOE+00 7.53E+05 Y-91M O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Y-91 9.54E+05 O.OOE+00 2.56E+04 O.OOE+00 O.OOE+00 O.OOE+00 3.91E+08 Y-92 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Y-93 3.71E-12 O.OOE+00 1.02E-13 O.OOE+00 O.OOE+00 O.OOE+0 1.13E-07 Zr-95 1.50E+06 4.74E+05 3.26E+05 O.OOE+00 6.96E+05 O.OOE+0O 1.09E+09 Zr-97 1.70E-05 3.37E-06 1.55E-06 0.OOE+00 5.1OE-06 0.OOE+0 9.11E-01 Nb-95 1.80E+06 9.98E+05 5.49E+05 O.OOE+00 9.67E+05 O.OOE+0O 4.27E+09 Mo-99 O.OOE+00 8.21E+04 1.57E+04 O.OOE+00 1.88E+05 O.OOE+00 1.47E+05 Tc-99M O.OOE+00 O.OOE+00 1.24E-19 O.OOE+00 1.43E-19 O.OOE+00 6.29E-18 Tc-101 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+00 O.OOE+0O Ru-103 8.56E+07 O.OOE+00 3.66E+07 O.OOE+00 3.02E+08 O.OOE+00 7.15E+09 Ru-105 O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Ru-106 2.36E+09 O.OOE+00 2.97E+08 O.OOE+00 4.55E+09 O.OOE+00 1.13E+i1I Ag-11OM 5.06E+06 4.79E+06 2.9 1E+06 O.OOE+00 9.13E+06 0.00E+00 1.35E+09 Page 11.4-63

CY-BY-1 70-301 Revision 8 Table 4-25 (Continued)

Teen Grass-Cow-Meat Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-125M 3.03E+08 1.09E+08 4.06E+07 8.47IE+07 0.OOE+00 O.OOE+00 8.95E+08 Te-127M 9.41E+08 3.34E+08 1.12E+08 2.24E+08 3.82E+09 0.OOE+00 2.35E+09 Te-127 2.12E-10 7.53E-11 4.57E-11 1.46E-10 8.60E-100.OOE+00 1.64E-08 Te-129M 9.49E+08 3.52E+08 1.50E+08 3.06E+08 3.97E+09 O.OOE+00 3.56E+09 Te-129 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 Te-131M 3.75E+02 1.80E+02 1.50E+02 2.70E+02 1.87E+03 0.OOE+00 1.44E+04 Te-131 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Te-132 1.14E+06 7.24E+05 6.81E+05 7.63E+05 6.94E+06 O.OOE+00 2.29E+07 1-130 1.63E-06 4.72E-06 1.88E-06 3.85E-04 7.27E-06 0.OOE+00 3.63E-06 1-131 8.92E+06 1.25E+07 6.71E+06 3.64E+09 2.15E+07 O.OOE+00 2.47E+06 1-132 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 1-133 3.09E-01 5.25E-01 1.60E-01 7.32E+01 9.20E-01 O.OOE+00 3.97E-01 1-134 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 1-135 3.79E-17 9.75E-17 3.61E-17 6.27E-15 1.54E-16 O.OOE+00 1.08E-16 Cs-134 5.23E+08 1.23E+09 5.71E+08 O.OOE+00 3.91E+08 1.49E+08 1.53E+07 Cs-136 9.34E+06 3.68E+07 2.47E+07 O.OOE+00 2.OOE+07 3.15E+06 2.96E+06 Cs-137 7.24E+08 9.63E+08 3.36E+08 0.OOE+00 3.28E+08 1.27E+08 1.37E+07 Cs-138 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 Ba-139 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 Ba-140 2.38E+07 2.91E+04 1.53E+06 O.OOE+00 9.88E+03 1.96E+04 3.67E+07 Ba-141 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 Ba-142 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00O0.OOE+00 0.00E+00 La-140 3.09E-02 1.52E-02 4.04E-03 O.OOE+00 0.OOE+0O O.OOE+00 8.73E+02 La-142 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 Ce-141 1.18E+04 7.87E+03 9.04E+02 0.OOE+00 3.70E+03 O.OOE+00 2.25E+07 Ce-143 1.67E-02 1.22E+01 1.36E-03 0.OOE+00 5.46E-03 0.OOE+00 3.66E+02 Ce-144 1.23E+06 5.08E+05 6.60E+04 0.OOE+00 3.04E+05 O.OOE+00 3.09E+08 Pr-143 1.77E+04 7.05E+03 8.79E+02 0.OOE+00 4.10E+03 O.OOE+00 5.81E+07 Pr-144 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 Nd-147 6.35E+03 6.90E+03 4.14E+02 0.OOE+00 4.05E+03 0.OOE+00 2.49E+07 W-187 1.73E-02 1.41E-02 4.94E-03 0.OOE+00 O.OOE+00 0.OOE+00 3.82E+00 Np-239 2.25E-01 2.12E-02 1.18E-02 0.OOE+00 6.66E-02 O.OOE+00 3.41E+03 Notes:

1) 2)

Units are m2 mrem/yr per tCi/sec.

For H-3 and C-14, the units are mrem/yr per pCi/m3.

Page 11.4-64

CY-BY-170-301 Revision 8 Table 4-26 Child Grass-Cow-Meat Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lun2 GI-LLI H-3 O.OOE+00 1.34E+02 1.34E+02 1.34E+02 1.34E+02 1.34E-+02 1.34E+02 C-14 5.29E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 Na-24 1.84E-03 1.84E-03 1.84E-03 1.84E-03 1.84E-03 1.84E-03 1.84E-03 Cr-51 O.OOE+00 0.OOE+00 8.78E+03 4.87E+03 1.33E+03 8.90E+03 4.66E+05 Mn-54 0.00E+00 8.01E+06 2.13E+06 O.OOE+00 2.25E+06 O.OOE+00 6.72E+06 Mn-56 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+0O Fe-55 4.57E+08 2.42E+08 7.51E+07 O.OOE+00 O.OOE+00 1.37E+08 4.49E+07 Fe-59 3.76E+08 6.08E+08 3.03E+08 O.OOE+00 O.OOE+00 1.76E+08 6.34E+08 Co-58 O.OOE+00 1.64E+07 5.03E+07 O.OOE+00 O.OOE+00 O.OOE+00 9.59E+07 Co-60 0.OOE+00 6.93E+07 2.04E+08 O.OOE+00 O.OOE+00 O.OOE+00 3.84E+08 Ni-63 2.91E+10 1.56E+09 9.91E+08 O.OOE+00 O.OOE+00 O.OOE+00 1.05E+08 Ni-65 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Cu-64 O.OOE+00 2.77E-07 1.67E-07 O.OOE+00 6.68E-0710.OOE+00 1.30E-05 Zn-65 3.75E+08 1.OOE+09 6.22E+08 O.OOE+00 6.30E+08 O.OOE+00 1.76E+08 Zn-69 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-83 O.OOE+O0 O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 Br-84 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 Br-85 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-86 O.OOE+00 5.78E+08 3.55E+08 O.OOE+00 O.OOE+00 O.OOE+00 3.72E+07 Rb-88 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 Rb-89 O.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 Sr-89 4.81E+08 O.OOE+00 1.37E+07 O.OOE+00 O.OOE+00 O.OOE+00 1.86E+07 Sr-90 1.57E+10 0.00E+00 3.15E+08 O.OOE+00 O.OOE+00 O.OOE+00 1.40E+08 Sr-91 2.26E-10 O.OOE+00 8.54E-12 O.OOE+00 O.OOE+00 O.OOE+00 5.OOE-10 Sr-92 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 Y-90 1.73E+02 O.OOE+00 4.62E+00 O.OOE+00 O.OOE+00 O.OOE+00 4.92E+05 Y-91M O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Y-91 1.80E+06 O.OOE+00 4.82E+04 O.OOE+00 O.OOE+00 O.OOE+00 2.40E+08 Y-92 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 Y-93 6.97E-12 O.OOE+00 1.91E-13 O.OOE+00 O.OOE+00 O.OOE+00 1.04E-07 Zr-95 2.67E+06 5.86E+05 5.22E+05 O.OOE+00 8.39E+05 O.OOE+00 6.11E+08 Zr-97 3.16E-05 4.57E-06 2.70E-06 O.OOE+00 6.56E-06 O.OOE+00 6.93E-01 Nb-95 3.11E+06 1.21E+06 8.64E+05 O.OOE+00 1.14E+06 0.OOE+00 2.24E+09 Mo-99 O.OOE+00 1. 14E+05 2.82E+04 O.OOE+00 2.44E+05 O.OOE+00 9.44E+04 Tc-99M O.OOE+00 1.18E-20 1.96E-19 O.OOE+00 1.72E-19 O.OOE+00 6.72E-18 Tc-101 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Ru-103 1.55E+08 O.OOE+00 5.95E+07 O.OOE+00 3.90E+08 O.OOE+00 4.OOE+09 Ru-105 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 Ru-106 4.44E+09 O.OOE+00 5.54E+08 O.OOE+00 5.99E+09 0.OOE+00 6.90E+10 Ag-i 10M 8.39E+06 5.67E+06 4.53E+06 O.OOE+00 1.06E+07 0.OOE+00 6.74E+08 Page 11.4-65

CY-BY-1 70-301 Revision 8 Table 4-26 (Continued)

Child Grass-Cow-Meat Dose Factors Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Te-125M 5.70E+08 1.54E+08 7.59E+07 1.60E+08 0.OOE+00 0.OOE+00 5.50E+08 Te-127M 1.77E+09 4.78E+08-2.1 1E+08 4.24E+08 5.06E+09 O.OOE+00 1.44E+09 Te-127 3.99E-10 1.08E-10 8.56E-11 2.76E-10 1.14E-090.OOE+00 1.56E-08 Te-129M 1.79E+09 5.OOE+08 2.78E+08 5.77E+08 5.25E+09 0.OOE+00 2.18E+09 Te-129 0.OOE+0O 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+0O Te-131M 6.97E+02 2.41E+02 2.57E+02 4.96E+02 2.33E+03 0.00E+00 9.78E+03 Te-131 O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 O.OOE+00 0.00E+00 O.OOE+0O Te-132 2.09E+06 9.23E+05 1.12E+06 1.34E+06 8.57E+06 0.OOE+00 9.30E+06 1-130 2.92E-06 5.89E-06 3.04E-06 6.49E-04 8.81E-06 O.OOE+00 2.76E-06 1-131 1.65E+07 1.66E+07 9.45E+06 5.50E+09 2.73E+07 0.OOE+00 1.48E+06 1-132 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 1-133 5.75E-01 7.1OE-01 2.69E-01 1.32E+02 1.18E+00O0.OOE+00 2.86E-01 1-134 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+0O 1-135 6.86E-17 1.23E-16 5.84E-17 1.09E-14 1.89E-16 O.OOE+00 9.40E-17 Cs-134 9.22E+08 1.51E+09 3.19E+08 O.OOE+00 4.69E+08 1.68E+08 8.16E+06 Cs-136 1.61E+07 4.43E+07 2.87E+07 O.OOE+00 2.36E+07 3.52E+06 1.56E+06 Cs-137 1.33E+09 1.28E+09 1.88E+08 O.OOE+00 4.16E+08 1.50E+08 7.99E+06 Cs-138 O.OOE+00 0.00E+00O0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 Ba-139 0.OOE+00 0.00E+00 O.OOE+00 O.OOE+0 0.0OOE+-0 0.OOE+00 0.OOE+00 Ba-140 4.39E+07 3.84E+04 2.56E+06 O.OOE+00 1.25E+04 2.29E+04 2.22E+07 Ba-141 O.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 Ba-142 O.OOE+00 O.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+O0 0.00EE+00 La-140 5.66E-02 1.98E-02 6.67E-03 0.OOE+00 O.OOE+00 O.OOE+00 5.52E+02 La-142 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 Ce-141 2.22E+04 1.11E+04 1.64E+03 0.OOE+00 4.85E+03 O.OOE+00 1.38E+07 Ce-143 3.14E-02 1.70E+01 2.46E-03 0.OOE+00 7.14E-03 O.OOE+00 2.49E+02 Ce-144 2.32E+06 7.26E+05 1.24E+05 0.OOE+00 4.02E+05 0.OOE+00 1.89E+08 Pr-143 3.34E+04 1.OOE+04 1.66E+03 0.OOE+00 5.44E+03 O.OOE+0O 3.61E+07 Pr-144 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+0O 0.OOE+00 0.00E+00 Nd-147 1.19E+04 9.65E+03 7.47E+02 O.OOE+00 5.29E+03 0.OOE+00 1.53E+07 W-187 3.21E-02 1.90E-02 8.52E-03 0.OOE+00 O.OOE+00 0.OOE+00 2.67E+00 Np-239 4.23E-01 3.04E-02 2.14E-02 0.OOE+00 8.79E-02 0.OOE+00 2.25E+03 Notes:

1) 2)

3)

Units are m2 mren/yr per gCi/sec.

For H-3 and C-14, the units are mrem/yr per RLCi/m 3.

The infant age group is assumed to receive no dose through the meat ingestion pathway therefore no dose factors are supplied.

Page 11.4-66

CY-BY-1 70-301 Revision 8 Table 4-27 Byron Station Characteristics LOCATION: 3.7 miles SSW of Byron, Illinois Characteristics of Elevated Release Point:

Not applicable (NA)

1)

Release Height =

m

2)

Diameter = _.m

3)

Exit Speed

=

ms 1

4)

Heat Content Kcal s1 Characteristics of Vent Stack Release Point

1)

Release Height = 60.66 ma

2)

Diameter = 2.80 m

3)

Exit Speed

= 13.00 msla Characteristics of Ground Level Point

1)

Release Height = 0 m

2)

Building Factor (D) =

60.6 ma Meteorological Data A 250 ft Tower is Located 1036 m SW of vent stack release point Tower Data Used in Calculations Wind Speed Differential Release Point and Direction Temperature Elevated (NA)

(NA)

Vent 250 ft 250-30 ft Ground 30 ft 250-30 ft a Used in calculating the meteorological and dose factors in Table 4-1 and Table 4-4.

Page 11.4-67

CY-BY-170-301 Revision 8 Table 4-28 Dose Factors for Noble Gases Nuclide Kr-83m Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Kr-90 Xe-1 31m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Xe-i 38 Ar-41 Beta Air Dose Factor Ni (mrad/yr Per uCi/m 3) 2.88E+02 1.97E+03 1.95E+03 1.03E+04 2.93E+03 1.06E+04 7.83E+03 1.11 E+03 1.48E+03 1.05E+03 7.39E+02 2.46E+03 1.27E+04 4.75E+03 3.28E+03 Beta Skin Dose Factor L4 (mrem/yr per uCi/m 3)

Gamma Air Dose Factor Mi (mrad/yr per uCi/m 3)

Gamma Total Body Dose Factor Ki (mrem/yr per uCi/m 3) 1.46E+03 1.34E+03 9.73E+03 2.37E+03 1.01 E+04 7.29E+03 4.76E+02 9.94E+02 3.06E+02 7.11 E+02 1.86E+03 1.22E+04 4.13E+03 2.69E+03 1.93E+01 1.23E+03 1.72E+01 6.17E+03 1.52E+04 1.73E+04 1.63E+04 1.56E+02 3.27E+02 3.53E+02 3.36E+03 1.92E+03 1.51E+03 9.21 E+03 9.30E+03 7.56E-02 1.17E+03 1.61 E+01 5.92E+03 1.47E+04 1.66E+04 1.56E+04 9.15E+01 2.51 E+02 2.94E+02 3.12E+03 1.81 E+03 1.42E+03 8.83E+03 8.84E+03 Source: Table B-1 of US NRC Regulatory Guide 1.109 Page 11.4-68

CY-BY-170-301 Revision 8 5.0 TOTAL DOSE 5.1 Total Dose Calculation Requirements 5.1.1 Total Effective Dose Equivalent Limits; 10CFR20 and 40CFR190 The Byron Station is required to determine the total dose to a member of the public due to all uranium fuel cycle sources in order to assess compliance with 40CFR190 as part of demonstrating compliance with 10CFR20.

The total dose for the uranium fuel cycle is the sum of doses due to radioactivity in airborne and liquid effluents and the doses due to direct radiation from contained sources at the nuclear power station. When evaluation of total dose is required for a station, the following contributions are summed:

Doses due to airborne and liquid effluents from the station.

  • Doses due to liquid effluents from nuclear power stations upstream.

Doses due to any onsite radioactive waste storage facilities, if applicable.

Doses due to ISFSI 10CFR20 requires compliance to dose limits expressed as "Total Effective Dose Equivalent" (TEDE). Although annual dose limits in 1 OCFR20 are now expressed in terms of TEDEs, 40CFR1 90 limits remain stated as organ dose. The NRC continues to require 10CFR50 Appendix I and 40CFR190 doses to be reported in terms of organ dose and not TEDE. Due to the fact that organ dose limits set forth in 40CFR190 are substantially lower than those of 10CFR20 (25 mrem/yr vs. 100 mrem/yr), the NRC has stated that demonstration of compliance with the dose limits in 40CFR190 will be deemed as demonstration of compliance with the dose limits of 10CFR20 for most facilities (Reference 104). In addition to compliance with 40CFR190, it may be necessary for a nuclear power plant to address dose from on-site activity by members of the public.

5.1.2. ISFSI 10CFR72.104 dose limits are the same as those specified by 40CFR1 90.

Page 11.5-1

CY-BY-170-301 Revision 8 ISFSI dose contribution is in the form of direct radiation as no liquid or gas releases are expected to occur. The 10CFR72.212 report prepared in accordance with ISFSI requirements assumes a certain array of casks exists on the pad. The dose contribution from this array of casks in combination with historical uranium fuel cycle operations prior to ISFSI operations was analyzed to be within the 40CFR190 and 10CFR72.104 limits, and is documented in Holtec Report No. HI-2084113, Dose Versus Distance from a HI-STORM 100S version B containing the MPC-32 for Byron/Braidwood.

If the dose limits of 40CFR190 or 10CFR72.104 are exceeded, a special report to the NRC as well as an appropriate request for exemption/variance is required to be submitted to the NRC.

The requirement that the dose limits of 10CFR72.104 apply to "any real individual" is controlled for ISFSI activities in the ISFSI 72.212 report. Therefore, for the purposes of analyzing dose from the ISFSI, the member of the public as defined in 40CFR1 90 is the same as the "real individual" identified in the 72.212 report.

5.1.3. Total Dose Calculation Methodology In addition to the total body, skin and single organ dose assessments previously described, an additional assessment is required. The additional assessment addresses radiation dose due to radioactivity contained within the nuclear power station and its structures.

Pressurized water reactors have the potential to affect off-site doses from contained sources of radioactivity, primarily due to gamma rays associated with radioactive material contained in onsite radwaste and radioactive material storage facilities.

5.2 Onsite Radwaste and Rad Material Storage Facilities A 10CFR50.59 analysis is required for radwaste storage facilities.

5.2.1 Process Waste Storage Facilities Interim Radwaste Storage Facility (IRSF) structure

  • Concrete vaults containing radwaste liners 5.2.2 DAW Storage Facilities Dry Active Waste (DAW) facilities (may include Butler buildings/warehouses)

" Seavans or other temporary warehouses Page 11.5-2

CY-BY-170-301 Revision 8 5.2.3 Replaced Steam Generator Storage Facilities 5.2.4 ISFSI Facilities 9 Independent spent fuel storage installation facilities.

5.3 Methodology The external total body dose is comprised of the following parts:

1)

Total body dose due to noble gas radionuclides in gaseous effluents (Section 4.2.2.3),

2)

Dose due to other contained sources and

3)

Total body dose due to radioactivity deposited on the ground (Section 4.2.3.1).

The external total body dose due to radioactivity deposited on the ground is accounted for in the determination of the non-noble gas dose and is considered in section 5.4.

The total external total body dose, D-x, is given by:

D== DTB +D sF (5-1)

D Ex Total External Total Body Dose

[mrem]

Total external total body dose due to irradiation by external sources at the location of interest.

DTB Noble Gas Total Body Dose

[mrem]

External total body dose due to gamma radiation from noble gas radionuclides released in gaseous effluents at the location of interest. See Section 4.2.2.3.

DOSF Dose From On-Site Storage Facilities

[mrem]

External total body dose due to gamma radiation from on-site storage facilities at the location of interest. See Section 5.2.

Page 11.5-3

CY-BY-170-301 Revision 8 5.4 Total Dose The total dose, DT~t, in the unrestricted area to a member of the public due to plant operations is given by:

DTot =D 1q r

+aNNG (5-2) where:

DTo Total Dose To Member of Public

[mrem]

Total off-site dose to a member of public due to plant operations.

D EX Total External Total Body Dose

[mrem]

Total body dose due to external exposure to noble gases, N-16 skyshine and on-site storage facilities.

D Liq Liquid Effluent Dose (mrem]

Dose due to liquid effluents to age group a and organ 1. The age group and organ with the highest dose from liquid effluents is used.

DaNG Non-Noble Gaseous Effluent Dose

[mrem]

Dose due to non-noble gaseous effluents to age group a and organ 1. The age group and organ with the highest dose from non-noble gas effluents is used.

5.5 COMPLIANCE TO TOTAL DOSE LIMITS 5.5.1 Total Effective Dose Equivalent Limit - 10CFR20 Compliance Each station's RE limits the Total Effective Dose Equivalent (TEDE) to an annual limit of 100 mrem, as required by 10CFR20.1301 (a)(1). Demonstration of compliance with the limits of 40CFR190 (per Section 4.2.2) will be considered to demonstrate compliance with the 100 mrem/year limit.

5.5.2 Dose to a Member of the Public in the Unrestricted Area The NRC has stated that demonstration of compliance with the limits of 40CFR1 90 or with the design objectives of Appendix I to 10CFR50 will be deemed to demonstrate compliance with the limits of 10CFR20.1301(a)(1). Power reactors that comply with Appendix Page 11.5-4

CY-BY-1 70-301 Revision 8 I may also have to demonstrate that they are within the 25 mrem limit of 40CFR1 90 (See Reference 104).

5.5.3 Dose to a Member of the Public in the Restricted Area In August of 1995, a revision to 1 OCFR20 was implemented that changed the definition of a member of the public. As a result, for each nuclear station, estimated doses were calculated for a member of the public who enters the site boundary, but is not authorized for unescorted access to the protected area of the site and does not enter any radiologically posted areas on the site.

Realistic assumptions were made for occupancy times and locations visited while within the site boundary.

These evaluations indicate that the doses estimated for these members of the public are well within the 10CFR20 limits. These dose evaluations will be performed annually and if necessary, a model will be developed and included in the ODCM.

Evaluation of the 40CFR190 dose is used to demonstrate compliance to 1 OCFR20 and satisfy station TRM and Technical Specifications (see ODCM Part I).

5.5.4 Total Dose due to the Uranium Fuel Cycle (40CFR190)

RE and 40CFR190 limit the annual (calendar year) dose or dose commitment to any member of the public due to releases of radioactivity and to radiation from uranium fuel cycle sources to the following:

Less than or equal to 25 mrem to the total body.

Less than or equal to 25 mrem to any organ except the thyroid.

Less than or equal to 75 mrem to the thyroid.

Total Dose Components This requirement includes the total dose from operations at the nuclear power station. This includes doses due to radioactive effluents (airborne and liquid) and dose due to direct radiation from non-effluent sources (e.g., sources contained in systems on site). It also includes dose due to plants under consideration, neighboring plants and dose due to other facilities in the uranium fuel cycle.

Page 11.5-5

CY-BY-170-301 Revision 8 The operations comprising the uranium fuel cycle are specified in 40CFR190.02(b). The following are included to the extent that they directly support the production of electrical power for public use utilizing nuclear energy:

Milling of uranium ore.

Chemical conversion of uranium.

Isotopic enrichment of uranium.

Fabrication of uranium fuel.

Generation of electricity by a light-watered-cooled nuclear power plant using uranium fuel.

Reprocessing of spent uranium fuel.

Excluded are:

Mining operations.

Operations at waste disposal sites.

Transportation of any radioactive material in support of these operations.

The re-use of recovered non-uranium special nuclear and by-product materials from the cycle.

5.6 When Compliance Assessment is Required Compliance with the 40CFR1 90 regulations is now required as part of demonstration of compliance to 1 OCFR20 regulations per 1 OCFR20.1301 (d).

The dose due to the uranium fuel cycle is determined by equation 5-2 Page 11.5-6

CY-BY-1 70-301 Revision 8 6.0 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM The radiological environmental monitoring program for the environs around Byron Station is given in Table 6-1.

Figures 6-1 through 6-4 show sampling and monitoring locations.

Page II 6-1

CY-BY-1 70-301 Revision 8 Table 6-1 Radiological Environmental Monitoring Program Exposure Pathway and/or Sample Sampling or Collection Frequency

1. Airborne Sampling or Monitoring Locations
a.

Indicators-Near Field BY-21 Radioiodine and Particulates Continuous sampler operation with particulate sample collection weekly, or more frequently if required by dust loading, and radioiodine canister collection weekly.

BY-22 BY-23 BY-24 Type or Frequency of Analysis Radioiodine Canister:

1-131 analysis weekly on near field and control samples.1 Particulate Sampler:

Gross beta analysis following weekly filter change and gamma isotopic analysis 3

quarterly on composite filters by location on near field and control samples.

b.

Indicators-Far Field BY-01, Byron BY-04, Paynes Pt.

BY-06, Oregon

c.

Controls BY-08, Leaf River Page II 6-2

CY-BY-1 70-301 Revision 8 I Table 6-1 (Cont.)

Radiological Environmental Monitoring Program Exposure Pathway and/or Sample

2. Direct Radiation Sampling or Collection Frequency Type or Frequency of Analysis Sampling or Monitoring Locations
a.

Indicators-Inner Ring Quarterly Gamma Dose Quarterly BY-101-1 BY-101-2 BY-102-1 BY-102-2 BY-1 03-1 BY-103-2 BY-103-3 BY-104-1 BY-104-2 BY-1 04-3 BY-105-1 BY-105-2 BY-1 06-1 BY-106-2 BY-107-1 BY-107-2 BY-107-3 BY-108-1 BY-108-2 BY-109-1 BY-109-2 BY-110-1 BY-1 10-2 BY-111-3 BY-111-4 BY-1 12-3 BY-1 12-4 Page II 6-3

CY-BY-1 70-301 Revision 8 Table 6-1 (Cont.)

Radiological Environmental Monitoring Program Exposure Pathway and/or Sample

2. Direct Radiation Sampling or Collection Frequency Type or Frequency of Analysis Samplinq or Monitoring Locations Indicators-Inner Ring (cont'd)

(cont'd)

BY-113-1 BY-113-2 BY-1 14-1 BY-1 14-2 BY-115-1 BY-1 15-2 BY-116-1 BY-116-2 BY-116-3

b.

Indicators-Outer Ring Quarterly Gamma Dose Quarterly BY-201-3 BY-201-4 BY-202-1 BY-202-2 BY-203-1 BY-203-2 BY-204-1 BY-204-2 BY-205-1 BY-205-2 BY-206-1 BY-206-2 BY-207-1 BY-207-2 Page II 6-4

CY-BY-1 70-301 Revision 8 Table 6-1 (Cont.)

Radiological Environmental Monitoring Program Exposure Pathway and/or Sample

2. Direct Radiation Sampling or Monitoring Locations Indicators-Outer Ring (cont'd)

Sampling or Collection Frequency Type of Frequency of Analysis (cont'd)

BY-208-1 BY-208-2 BY-209-1 BY-209-4 BY-210-3 BY-210-4 BY-211-1 BY-211-4 BY-212-1 BY-212-4 BY-213-1 BY-213-4 BY-214-1 BY-214-4 BY-215-1 BY-215-4 BY-216-1 BY-216-2

c.

Indicators-Other Quarterly Gamma Dose Quarterly BY-01 -1 BY-01 -2 BY-04-1 BY-04-2 BY-24-1 BY-24-2 BY-06-1 BY-06-2 BY-21-1 Page II 6-5

CY-BY-170-301 Revision 8 Exposure Pathway and/or Sam ple

2. Direct Radiation (cont'd)

Table 6-1 (Cont)

Radiological Environmental Monitoring Program Sampling or Sampling or Monitoring Locations Collection Frequency Indicators-Other (cont'd)

BY-21-2 BY-22-1 BY-22-2 BY-23-1 BY-23-2

d.

Control BY-08-1 BY-08-2

e.

Special Interest BY-301 -1 BY-302-1 BY-309-1 BY-309-2 BY-309-3 BY-309-4 BY-314-1 Type of Frequency of Analysis Page II 6-6

CY-BY-170-301 Revision 8 I Table 6-1 (Cont.)

Radiological Environmental Monitoring Program Exposure Pathway and/or Sample Sampling or Monitorinq Locations Sampling or Collection Frequency

3. Waterborne Ground/Well Type or Frequency of Analysis Gamma isotopic3 and tritium analysis quarterly.
a.

Indicators Quarterly BY-14-1, 3200 German Church Rd BY-18-1, Calhoun Well BY-32, Wolford Well BY-35, Vancko Well BY-36, Blanchard Well BY-37, Alexander Well Drinking Surface There is no drinking water pathway within 6.2 mi downstream of the station.

a.

Indicators BY-12, Oregon Pool of Rock River, Downstream of Discharge Weekly grab samples.

Gross beta and.9amma isotopic analysis on monthly composite; tritium analysis on quarterly composite.

b.

Control BY-29, Byron, Upstream of Intake

a.

Indicators BY-12, Oregon Pool of Rock River, Downstream of Discharge Sediment Semiannually Gamma isotopic 3 analysis semiannually.

b.

Control BY-34, Rock River Upstream of discharge Page II 6-7

CY-BY-1 70-301 Revision 8 Table 6-1 (Cont.)

Radiological Environmental Monitoring Program Exposure Pathway and/or Sample

4. Ingestion Milk Sampling or Monitoring Locations
a.

Indicators BY-20-1 R. Snodgrass,Dairy Farm BY-30-1 Ebert Farm

b.

Controls BY-26-1, Dennis Herbert's Dairy

a.

Indicator Sampling or Collection Frequencv Biweekly: May through October; monthly:

November through April.

Type or Frequency of Analysis Gamma isotopic 3 and 1-131 analysis 4 on each sample.

Fish BY-31, Rock River in vicinity of Discharge Two times annually

b.

Control Gamma isotopic 3 analysis on edible portions.

BY-29, Byron, Upstream of Intake Food Products

a.

Indicators Annually Gamma isotopic 3 analysis on each sample.

Two samples from each of the four major quadrants within 6.2 miles of the station.

Page II 6-8

CY-BY-170-301 Revision 8 Table 6-1 (Cont.)

Radiological Environmental Monitoring Program Exposure Pathway and/or Sample Sampling or Collection Frequency SamDlina or Monitorina Locations Food Products (cont'd)

b.

Control Annually Type of Frequency of Analysis Gamma Isotopic 3 analysis on each sample.

Two samples within 9.3 to 18.6 miles of the station.

Sample locations for food products may vary based on availability and therefore are not required to be identified here but shall be taken.

Page UI 6-9

CY-BY-1 70-301 Revision 8 Table 6-1 (Cont'd)

Radiological Environmental Monitoring Program 1Far field samples are not required to be analyzed, unless the respective near field sample results are inconsistent with previous measurements and radioactivity is confirmed as having its origin in airborne effluents from the station, or at the discretion of the Chemistry Manager.

2Airborne particulate sample filters shall be analyzed for gross beta radioactivity 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or more after sampling to allow for radon and thoron daughter decay. If gross beta activity in air particulate samples is greater than ten times the yearly mean of control samples, gamma isotopic analysis shall be performed on the individual samples.

3Gamma isotopic analysis means the identification and quantification of gamma-emitting radionuclides that may be attributable to the effluents from the station.41-131 analysis means the analytical separation and counting procedure are specific for this radionuclide.

Page II 6-10

CY-BY-170-301 Revision 8 REFEREN; UNITED STATES GEOLOGIC SURVEY STILLMAN VALLEY QUADRANGLE, OR TOPOGRAPHIC. 7.5 MINUTES SERIES 197l 0

112 1,M 0

1/2 1 MILE AR SAMPUNG LOCAllON OFFSITE OOSE CALCULATION MANUAL BYRON STATION FIGURE 6-1 ONSITE AIR SAMPLING LOCATIONS and Unrestricted Area Boundary Page II 6-11

CY-BY-1 70-301 Revision 8 OFPS1TE DOSE CALCULATION MANUAL SAMR SDOMUNG ULCAUIM U

M!ON T*MA1I OFFSITE DOSE CALCULATION MANUAL BYRON STATION FIGURE 6-2 OFFSITE AIR SAMPLING LOCATIONS Page 116-12

CY-BY-1 70-301 Revision 8 e Dosimeter Location OFFSITE DOSE CALCULATION MANUAL BYRON STATION FIGURE 6-3 INNER RING AND OUTER RING DOSIMETER LOCATIONS Page II 6-13

CY-BY-170-301 Revision 8 0

0 F ISH MILK SEDIMENT WATER BYRON STATION PLANT LIQUID DISCHARGE OFFSITE DOSE CALCULATION MANUAL BYRON STATION FIGURE 6-4 INGESTION AND WATERBORNE EXPOSURE PATHWAY SAMPLE LOCATIONS Page 116-14

CY-BY-1 70-301 Revision 8 Latitude/Longitude Positions of REMP Samples Table 6-2 Sampling Location Latitude Longitude Distance Distance Direction Sector Compass (deg)

(deg)

(kmn)

(mi)

(deg)

Desig Dr J Release (Reference) Point Vent Stack 142.07472 1 -89.282641 N/A N/A J N/A IN/AJ N/A Air Samp ing Stations BY-01 42.11762

-89.27993 4.77 2.96 3

A N

BY-04 42.01867

-89.22213 7.98 4.96 142 G

SE BY-06 42.01577

-89.33010 7.63 4.74 211 K

SSW BY-08 42.12668

-89.39918 11.20 6.96 301 P

WNW BY-21 42.07908

-89.28213 0.49 0.30 5

A N

BY-22 42.07168

-89.27693 0.58 0.36 125 G

SE BY-23 42.06585

-89.28230 0.98 0.61 178 J

S BY-24 42.06790

-89.29278 1.13 0.70 228 L

SW Surface Water BY-12 42.017 E-89.32603 7.33 4.55 I 209 I

K SSW BY-29 42.11773

-89.27990 4.78 2.97 3

A N

Sediment BY-12 42.0177i

-89.32603 7.33 4.55 209 K

SSw BY-34 42.09355

-89.32638 4.18 2.60 300 P

WNW Fish BY-29 42.11773

-89.27990 4.78 2.97 3

A N

BY-31 42.09353

-89.32623 4.16 2.58 300 P

WNW Milk BY-20-1 42.05898

-89.37455 7.80 4.85 257 M

WSW BY-26-1 42.25968

-89.27630 20.60 12.80 1

A N

BY-30-1 42.14778

-89.31617 8.58 5.33 341 R

NNW Well Water BY-14-1 42.06102

-89.27753 1.58 0.98 164 H

SSE BY-18-1 42.06578

-89.29051 1.19 0.74 213 K

SSW BY-32 42.07527

-89.31863 3.00 1.86 271 N

W BY-35 42.08097

-89.31802 3.01 1.87 283 P

WNW BY-36 42.01867

-89.29600 1.35 0.84 305 Q

NW BY-37 42.08225

-89.31928 3.14 1.95 285 P

WNW Vegetation BY-Control Varies by Varies by year Varies by Varies by Varies by year Varies by Varies by year Year year year year BY-Quad I Varies by Varies by year Varies by Varies by Varies by year Varies by Varies by year year year year year BY-Quad 2 Varies by Varies by year Varies by Varies by Varies by year Varies by Varies by year year year year year BY-Quad 3 Varies by Varies by year Varies by Varies by Varies by year Varies by Varies by year year year year year BY-Quad 4 Varies by Varies by year Varies by Varies by Varies by year Varies by Varies by I__ year I

year year year year Page 116-15

CY-BY-170-301 Revision 8 Latitude/Longitude Positions of REMP Samples Table 6-2 Dosimeter Locations Sampling Location Latitude Longitude Distance Distance Direction Sector Sector (deg)

(deg)

(km)

(mi)

(deg)

From Stack Inner Ring BY-101-1 42.07908

-89.28243 0.48 0.30 2

A N

BY-101-2 42.07912

-89.28188 0.49 0.30 8

A N

BY-102-1 42.08757

-89.27522 1.56 0.97 23 B

NNE BY-102-2 42.08752

-89.27438 1.58 0.98 26 B

NNE BY-103-1 42.09068

-89.25822 2.69 1.67 49 C

NE BY-103-2 42.09020

-89.25802 2.67 1.66 50 C

NE BY-103-3 42.07893

-89.27692 0.67 0.42 45 C

NE BY-104-1 42.08345

-89.25798 2.26 1.40 65 D

ENE BY-104-2 42.08303

-89.25797 2.24 1.39 66 D

ENE BY-104-3 42.07720

-89.27717 0.53 0.33 59 D

ENE BY-105-1 42.07462

-89.25777 2.06 1.28 59 E

E BY-105-2 42.07598

-89.25760 2.08 1.29 90 E

E BY-106-1 42.06822

-89.25770 2.19 1.36 109 F

ESE BY-106-2 42.06770

-89.25758 2.22 1.38 111 F

ESE BY-107-1 42.05870

-89.26647 2.23 1.39 143 G

SE BY-107-2 42.05873

-89.26580 2.26 1.40 142 G

SE BY-107-3 42.07027

-89.27730 0.66 0.41 138 G

SE BY-108-1 42.06588

-89.27790 1.06 0.66 158 H

SSE BY-108-2 42.06578

-89.27920 1.03 0.64 164 H

SSE BY-109-1 42.06580

-89.28417 1.00 0.62 187 J

S BY-109-2 42.06583

-89.28427 1.00 0.62 188 J

S BY-110-1 42.06578

-89.28738 1.07 0.66 201 K

SSW BY-110-2 42.06577

-89.28793 1.08 0.67 204 K

SSW BY-111-3 42.06573

-89.29173 1.25 0.78 217 L

SW Page 116-16

CY-BY-1 70-301 Revision 8 Latitude/Longitude Positions of REMP Samples Table 6-2 Dosimeter Locations Inner Ring BY-111-4 42.06565

-89.29363 1.36 0.85 222 L

SW BY-112-3 42.06967

-89.29660 1.28 0.80 244 M

WSW BY-112-4 42.07010

-89.29653 1.26 0.78 246 M

WSW BY-1 13-1 42.07385

-89.29670 1.16 0.72 265 N

W BY-113-2 42.07432

-89.29662 1.15 0.71 268 N

W BY-114-1 42.07955

-89.29665 1.27 0.79 295 P

WNW BY-114-2 42.08000

-89.29673 1.30 0.81 297 P

WNW BY-115-1 42.08433

-89.27905 1.60 0.99 312 Q

NW BY-115-2 42.08473

-89.29702 1.63 1.01 313 Q

NW BY-116-1 42.09185

-89.29697 2.24 1.39 328 R

NNW BY-1 16-2 42.09227

-89.29705 2.28 1.42 329 R

NNW BY-116-3 42.08702

-89.28810 1.44 0.89 342 R

NNW Page 116-17

CY-BY-1 70-301 Revision 8 Latitude/Longitude Positions of REMP Samples Table 6-2 Dosimeter Locations Continued I

Outer Ring BY-201-3 42.13811

-89.28378 7.04 4.37 359 A

N BY-201-4 42.01381

-89.28316 7.04 4.37 360 A

N BY-202-1 42.13623

-89.25798 7.13 4.43 17 B

NNE BY-202-2 42.14157

-89.25817 7.70 4.78 15 B

NNE BY-203-1 42.12840

-89.22405 7.69 4.78 39 C

NE BY-203-2 42.12258

-89.21855 7.51 4.67 45 C

NE BY-204-1 42.10407

-89.21380 6.57 4.08 60 D

ENE BY-204-2 42.09472

-89.20980 6.43 4.00 70 D

ENE BY-205-1 42.08028

-89.20923 6.11 3.80 84 E

E BY-205-2 42.07587

-89.20907 6.09 3.78 89 E

E BY-206-1 42.05707

-89.20862 6.44 4.00 108 F

ESE BY-206-2 42.04622

-89.20870 6.89 4.28 117 F

ESE BY-207-1 42.02793

-89.23200 6.68 4.15 141 G

SE BY-207-2 42.03008

-89.23523 6.32 3.93 142 G

SE BY-208-1 42.02425

-89.24565 6.39 3.97 151 H

SSE BY-208-2 42.02340

-89.25740 6.07 3.77 160 H

SSE BY-209-1 42.01717

-89.27887 6.40 3.98 177 J

S BY-209-4 42.01657

-89.27917 6.47 4.02 177 J

S BY-210-3 42.02180

-89.31012 6.30 3.91 201 K

SSW BY-210-4 42.02180

-89.31083 6.32 3.93 202 K

SSW BY-211-1 42.02658

-89.35338 7.93 4.93 228 L

SW BY-211-4 42.02645

-89.35278 7.90 4.91 227 L

SW Page 116-18

CY-BY-1 70-301 Revision 8 Latitude/Longitude Positions of REMP Samples Table 6-2 Dosimeter Locations Continued I

Outer Ring BY-212-1 42.04847

-89.36643 7.52 4.67 247 M

WSW BY-212-4 42.04888

-89.36672 7.52 4.67 248 M

WSW BY-213-1 42.07263

-89.37440 7.59 4.72 268 N

w BY-213-4 42.07183

-89.37440 7.60 4.72 268 N

w BY-214-1 42.09397

-89.36945 7.49 4.65 287 P

WNW BY-214-4 42.09397

-89.36890 7.45 4.63 287 P

WNW BY-215-1 42.11618

-89.34107 6.68 4.15 314 Q

NW BY-215-4 42.11710

-89.34100 6.74 4.19 314 Q

NW BY-216-1 42.13058

-89.32910 7.30 4.54 328 R

NNW BY-216-2 42.13847

-89.31702 7.63 4.74 338 R

NNW Special Interest BY-301-1 42.07830

-89.28338 0.40 0.25 352 A

N BY-302-1 42.00762

-89.28165 0.19 0.12 27 B

NNE BY-309-1 42.06995

-89.28268 0.53 0.33 183 J

S BY-309-2 42.06887

-89.28200 0.65 0.40 175 J

S BY-309-3 42.06865

-89.28358 0.68 0.42 186 J

S BY-309-4 42.06850

-89.28472 0.71 0.44 194 K

SSW BY-314-1 42.07593

-89.28742 0.41 0.25 289 P

WNw Page 116-19