8 AARTLETT ENGINEERING CALCULATION Calculation Number:
ENG-HB-003 Revision Number:
0 Calculation
Title:
Humboldt Bav Soil Derived Concentration Guideline Levels r
Preparer:,
Date 2 1/Z//-
,/,Z Ir, 12-5~c~ I-Bartlett Nuclear Inc.
60 Industrial Park Road Plymouth, MA 02360
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 1.0 PURPOSE The purpose of this calculation is to develop derived concentration guideline levels (DCGLs) for assessing soil at the Pacific Gas & Electric (PGE) Humboldt Bay nuclear power site. This calculation is a deliverable product specified in the scope of work section in Contract No. GTO12 3500895165.
2.0 APPLICABILITY This calculation addresses only the development of DCGLs for surface soils at the PGE Humboldt Bay site.
3.0 REFERENCES
3.1 ENG-HB-001, RESRAD Input Parameter Sensitivity Analysis - Humboldt Bay 3.2 ANL/EAIS-8, Data Collection Handbook to Support Modeling the Impacts of Radioactive Material in Soil; U.S. Department of Energy - Argonne National Laboratory, April 1993.
3.3 NUREG/CR-5512, Volume 1, Residual Radioactive Contamination from Decommissioning: Technical Basis for Translating Contamination Levels to Annual Total Effective Dose Equivalent, Final Report, U.S. Nuclear Regulatory Commission, October 1992.
3.4 ANL/EAD-4, User's Manual for RESRAD Version 6, U.S. Department of Energy -
Argone National Laboratory, July, 2001.
3.5 NUREG/CR-6697, Development of Probabilistic RESRAD 6.0 and RESRAD-BUILD 3.0 Computer Codes, U.S. Nuclear Regulatory Commission, December 2000.
3.6 Procedure ENG-AP-02, Verification of Software Operability 3.7 NUREG/CR-6676, Probabilistic Dose Analysis Using Parameter Distributions Developed for RESRAD and RESRAD-Build Codes, May 2000 (ANL/EAD/TM-89) 3.8 HBPP-TBD-001, Site-Specific Suite of Radionuclides, 8/2007.
3.9 Humboldt Bay SAFSTOR Environmental Report, July 1984..
3.10 Humboldt Bay Power Plant License Termination Plan, Chapter 6, Compliance with the Radiological Criteria for License Termination, draft 11/2010 3.11 Humboldt Bay Power Plant Historical Site Assessment, 9/2008 4.0 METHOD OF CALCULATION The operability of the RESRAD Version 6.5 code was verified on each computer used for code executions in accordance with Bartlett Engineering procedure ENG-AP- 02, Verification of Software Operability [ref. 3.5]. The RESRAD User's manual [ref. 3.3] provided guidance for code operation and execution.
The RESRAD code has undergone extensive review, benchmarking, verification, and validation. Details on reviews, benchmarking, verification, and W) BARTLETT Page 2
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 validation for the RESRAD code are summarized in Sections 5.1-5.4 of RESRAD User's manual [ref. 3.3].
The RESidual RADioactivity (RESRAD) model and computer code was developed at Argonne National Laboratory (ANL) as a multifunctional tool to assist in developing radiological criteria for unrestricted release and assessing the dose or risk associated with residual radioactive material. The RESRAD computer code is a pathway analysis model designed to evaluate the potential radiological dose associated with residual radioactive material for a defined receptor scenario. The RESRAD software allows the user to evaluate radiation exposure through several pathways: direct external radiation, inhalation, ingestion of plants, meat, milk, aquatic foods, and drinking water, inadvertent ingestion of contaminated soil, and radon exposure.
In the previous Bartlett Engineering Calculation ENG-HB-001 (ref. 3.1), the probabilistic modules in RESRAD Ver. 6.5 were used to perform a sensitivity analysis to identify parameters that have the greatest impact on dose. The results from these RESRAD Ver. 6.5 Uncertainty Analysis output reports were used to determine which stochastic parameters were sensitive based on an absolute value of the PRCC exceeding the sensitivity threshold (0.25).
The RESRAD Ver. 6.5 Interactive Report was than used to identify the 25th or 75th percentile values for the sensitive parameters shown in Table 1.
The values summarized in Table 2, which include reasonably conservative values for the identified sensitive RESRAD parameters, were used as input in separate executions of the RESRAD code for each of the radionuclides of concern (ROCs) at the Humboldt Bay site. The probabilistic module of RESRAD software was used to compute a "peak of the mean" (POM) dose. The POM dose for each ROC was used to determine the DCGL value that corresponded to the NRC dose criteria established in 10CFR20.1403 (i.e., 25 mrem/y). The DCGL value for each ROC was calculated as follows:
DCGL(pCi/g) = 25 mrem/y divided by POM dose (mrem/y per pCi/g).
5.0 ASSUMPTIONS AND INPUT 5.1 Assumptions 5.1.1. Radionuclides of Concern (ROC). Twenty-two ROCs are identified for the Humboldt Bay [refs. 3.8 and 3.10]: Am-241, C-14, Cm243/244/245/246, Co-60, Cs-137, Eu-152, Eu-154, H-3, 1-129, Nb-94, Ni-59, Ni-63, Np-237, Pu-238/239/240/241, Sr-90, and Tc-99.
5.1.2. Resident Farmer Scenario: The dose model used to perform the sensitivity analyses is based upon the Resident Farmer Scenario defined in NUREG/CR-5512 Volume 3 (Ref. 3.2). The average member of the critical group is the resident farmer that lives on the plant site, grows all or a portion of his / her diet onsite, and drinks water from a groundwater source onsite. The pathways used to estimate human radiation exposure resulting from residual radioactivity in the soil for this scenario includes the following:
0 Direct external radiation exposure pathway; Inhalation exposure pathway;
- Ingestion exposure pathway:
- plant foods grown in the soil material containing residual radioactivity, B A RT L E TT Page 3
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0
- meat and milk from livestock fed with fodder grown in soil containing residual radioactivity and watercontaining residual radioactivity,
- drinking water containing residual radioactivity from a well, and
- aquatic food from a pond containing residual radioactivity; Inadvertent ingestion of contaminated soil 5.1.3. Conceptual Model: The conceptual hydrological model for this resident farmer scenario has three geological strata: 1) a contaminated zone, 2) an unsaturated zone, and 3) a saturated zone. The contaminated zone is assumed to be uncovered, equivalent in size to the largest contiguous Class 1 and 2 area at the Humboldt Bay site (see Figure 2), and variable in thickness.
The unsaturated zone is initially uncontaminated and also variable in thickness. The groundwater in the saturated zone is assumed initially uncontaminated.
5.2 Input The bases and derivations for input listed below have been documented in Reference 3.1 and are only summarized here. For additional details, refer to Reference 3.1.
5.2.1. Contaminated zone: The thickness of the contaminated zone was determined from characterization soil sample data that showed plant-related radioactivity was detected in surface soil samples (6 inches or less in depth) to a sub-surface depth of approximately 12 feet. A site-specific uniform distribution was developed and used in the sensitivity analysis (Ref. 3.1). The thickness of the contaminated zone was identified as a sensitive RESRAD input parameter for most ROCs (Ref. 3.1).
Therefore, to increase conservatism and to account for the uncertainty in the thickness of the contaminated zone, the 7 5th percentile value from the site-specific distribution (provided in Table 1) is used as input for developing DCGLs.
"Clay loam" was selected from the soil type as a reasonably representative soil type for the contaminated zone (refer to ENG-HB-001 [ref. 3.1] for a detailed description of the approach). The "clay loam" soil classification was used as the basis for selecting input for other soil type-dependent parameters, such as hydraulic conductivity and the RESRAD soil-b parameter.
5.2.2. Unsaturated zone: A uniform distribution was established based groundwater well data showing on a minimum thickness equal to 0 inches and a maximum thickness equal to 26.5 feet (details are provided in ENG-HB-001 [ref. 3.1]).
"Clay loam" was selected from the soil type as reasonably representative soil type for the unsaturated zone. The "clay loam" soil classification was used as the basis for selecting input for other soil type-dependent parameters, such as effective porosity, hydraulic conductivity, and the RESRAD soil-b parameter.
5.2.3. Saturated zone: "Silty clay loam" was selected as reasonably representative soil type for the saturated zone. The "silty clay loam" soil classification was used as the basis for selecting input for other soil type-dependent parameters, such as effective porosity, hydraulic conductivity, and the RESRAD soil-b parameter.
VBARTLETT Page 4
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 5.2.4. The value of the Lower Elk River Watershed [from the Humboldt Bay Power Plant FSAR], 2.52E+07 M2, was used as input for the RESRAD parameter "Watershed Area for Nearby Streams and Ponds."
5.2.5. Input values for annual precipitation and evapo-transpiration were obtained from the SAFSTOR Environmental Report [ref 3.9].
NOAA recorded average wind speed data obtained from the National Climate Data Center website were used as the basis for wind speed.
5.2.6. Calculations for input values for the following RESRAD parameters are provided in ENG-HB-001 [ref. 3.1]:
Area of the Contaminated Zone and length parallel to the aquifer Contaminated zone erosion rate Field capacity for the contaminated, unsaturated, and saturated zones Hydraulic conductivity in the unsaturated zone Runoff Coefficient Fraction of Time Spent Indoors and Fraction of Time Spent Outdoor Irrigation Rate and Well Pumping Rate Inhalation Rate Soil Ingestion Rate Drinking Water Intake 5.2.7. Table 2 summarizes the parameter name, type, priority, treatment, values/distribution and the reference source that provides the bases for each input parameter.
6.0 RESULTS 6.1 RESRAD 6.5 was executed for each ROCs using the input values provided in Table
- 2. Table 3 summarizes the POM dose for each ROC. Selected pages from the RESRAD 6.5 Summary and Uncertainty Reports from each code execution are provided in Appendix A.
6.2 The DCGL for each ROC was calculated from POM dose using the following relationship:
DCGL(pCi/g) = 25 mrem/y divided by POM (mrem/y per pCi/g) 6.3 Table 3 provides the DCGL corresponding to an annual dose equal to 25 mrem under the resident farmer scenario.
6.4 For practical application, the DCGL values were rounded down to 2 significant digits. Table 4 presents the rounded DCGL values.
WYBARTLETT Page 5
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Table 1: RESRAD-Generated Percentile Values for Sensitive Input Parameters (copy of Table 4 in Reference 3.1)
RESRAD Percentile Valuea Sensitive Input Parameter Affected Nuclide 2 5 th 7 5 th Thickness of contaminated zone (m)
Am-241, C-14, Cm-243/244/245/246, 2.67E+00 Co-60, Cs-1 37, H-3, 1-129, Ni-59, Ni-63, Np-237, Pu-238/239/240/241, Sr-90, Tc-99 Depth of roots (m)
Am-241, C-14, Cm-243/244/245/246, 1.22E+00 Co-60, Cs-137, H-3, 1-129, Ni-59, Ni-63, Np-237, Pu-238/239/240/241, Sr-90, Tc-99 External shielding factor Cm-243, Co-60, Cs-1 37, Eu-152, Eu-3.98E-01 154, Nb-94 Thickness of evasion layer (m)
C-14 4.27E-01 Plant transfer factor Am-241 (the plant transfer factor was 1.83E-03 (pCi/g plant per pCi/g soil) also found sensitive for the Am-241 as a daughter product for Pu-241)
Cm-243/244/245/246 1.83E-03 Co-60 1.46E-01 Cs-1 37 7.82E-02 1-129 3.67E-02 Ni-59/63 9.12E-02 Np-237 3.67E-02 Pu-238/239/240 1.83E-03 Sr-90 5.90E-01 Tc-99 9.16E+00 Meat transfer factor (pCi/kg per pCi/d)
Co-60 5.86E-02 Cs-137 6.52E-02 1-129 5.23E-02 Milk transfer factor (pCi/I per pCi/d)
Cs-1 37 1.39E-02 1-129 1.39E-02 Ni-59/63 3.21 E-02 Kd in contaminated zone (cm 3/g)
Am-241 (as daughter product for Pu-1.20E+04 241)
Eu-1 52 7.22E+03 H-3 4.30E-02 Nb-94 3.56E+03 Tc-99 4.28E+00 a The 751h percentile value was selected when the absolute value of the PRCC for a given parameter was >0.25 and PRCC had a positive value. The 25th percentile value was selected when the absolute value of the PRCC value for a given parameter was >_0.25 and the PRCC had a negative value. Refer to Reference 3.1 for additional details.
OW8ARTLETT Page 6
Bartlett Engineering.
Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Table 2: Summary of Values for RESRAD Input Parameters Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersd 1
2 3
4 Mean/
____Median Soil Concentrations Basic radiation dose limit (mrem/y) 3 D
25 100CFR 20.1402
[NR NR NR N
Initial principal radionuclide (pCi/g)
P 2
D 1
Unit Value NR NR NR NR Distribution coefficients (applied to contaminated, unsaturated, and saturated zones unless otherwise noted) (cm"/g)
Ac-227 (daughter for Cm-243 and P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 6.72 3.22 0.001 0.999 825 Pu-239)
Am-241 (also daughter for Cm-245 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 7.28 3.15 0.001 0.999 1445 and Pu-241)
D 1.20E+04 7 51h percentile value -
applied to Am-241 as daugther for Pu-241 in contaminated zone Am-243 (daughter for Cm-243)
P 1
S Truncated lognormal-n NUREG/CR-6697, Att. C 7.28 3.15 0.001 0.999 1445 C-14 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 2.4 3.22 0.001 0.999 11 Cm-243 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 8.82 1.82 0.001 0.999 6761 Cm-244 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 8.82 1.82 0.001 0.999 6761 Cm-245 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 8.82 1.82 0.001 0.999 6761 Cm-246 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 8.82 1.82 0.001 0.999 6761 Co-60 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 5.46 2.53 0.001 0.999 235 Cs-I 37 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 6.1 2.33 0.001 0.999 446 Eu-i 52 P
1 D
7.22E+03 7 5 h percentile value applied to contaminated zone only.
Truncated lognormal-n NUREG/CR-6697, Att. C; 6.72 3.22 0.001 0.999 825 distribution applied to saturated and I_
junsaturated zones.
Eu-154 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 6.72 3.22 0.001 0.999 825 Gd-152 (daughter for Eu-152)
P 1
S Truncated lognormal-n NUREG/CR-6697, Att. C 6.72 3.22 0.001 0.999 825 (0 BARTLETT Page 7
Bartlett Engineering.
Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersd 1
2 3
4 Mean/
Median H-3 P
1 S
4.30E-02 2 5" percentile value applied to contaminated zone only.
Truncated lognormal-n NUREG/CR-6697, Att. C;
-2.81 0.5 0.001 0.999 0.06 distribution applied to saturated and unsaturated zones.25th percentile value 1-129 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 1.52 2.19 0.001 0.999 4.6 Nb-94 P
1 D
3.56E+03 7 5h percentile value applied to contaminated zone only.
Truncated lognormal-n NUREG/CR-6697, Att. C; 5.94 3.22 0.001 0.999 380 distribution applied to saturated and unsaturated zones.
Ni-59 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 6.05 1.46 0.001 0.999 424 Ni-63 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 6.05 1.46 0.001 0.999 424 Np-237 (also daughter for Am-241, P
1 S
Truncated lognormal-n NUREG/CR-6697, Att, C 2.84 2.25 0.001 0.999 17 Cm-245, and Pu-241)
Pa-231 (daughter for Cm-243 and P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 5.94 3.22 0.001 0.999 380 Pu-239)
Po-210 (daughter for Cm-246)
P 1
S Truncated lognormal-n NUREG/CR-6697, Att. C 5.20 1.68 0.001 0.999 181 Pb-210 (daughter for Cm-246 and P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 7.78 2.76 0.001 0.999 2392 Pu-238)
Pu-238 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 6.86 1.89 0.001 0.999 953 Pu-239 (also daughter for Cm-243)
P 1
S Truncated lognormal-n NUREG/CR-6697, Att. C 6.86 1.89 0.001 0.999 953 Pu-240 (also daughter for Cm-244)
P 1
S Truncated lognormal-n NUREG/CR-6697, Att. C 6.86 1.89 0.001 0.999 953 Pu-241 (also daughter for Cm-245)
P 1
S Truncated lognormal-n NUREG/CR-6697, Att. C 6.86 1.89 0.001 0.999 953 Pu-242 (daughter for Cm-246)
P 1
S Truncated lognormal-n NUREG/CR-6697, Att. C 6.86 1.89 0.001 0.999 953 Ra-226 (daughter for Cm-246 and P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 8.17 1.7 0.001 0.999 3533 Pu-238)
Ra-228 (daughter for Cm-244 and P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 8.17 1.7 0.001 0.999 3533 Pu-240)
I I
I I
I I
I I
Sr-90 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 3.45 2.12 0.001 0.999 32 BARTLETT Page 8
Bartlett Engineering.
Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersd 1
2 3
4 Mean/
Median Tc-99 p
1 D
4.28E+00 7 5 h percentile value applied to contaminated zone only.
Truncated lognormal-n NUREG/CR-6697, Att. C;
-0.67 3.16 0.001 0.999 0.51 distribution applied to saturated and unsaturated zones.
Th-228 (daughter for Cm-244 and P
1 S
Truncated lognormal-n NUREG/CR-6697, Aft. C 8.68 3.62 0.001 0.999 5884 Pu-240)
Th-229 (daughter for Am-241, Cm-P 1
S Truncated lognormal-n NUREG/CR-6697, Att. C 8.68 3.62 0.001 0.999 5884 245, Np-237, and Pu-241)
Th-230 (daughter for Cm-246 and P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 8.68 3.62 0.001 0.999 5884 Pu-238)
Th-232 (daughter for Cm-244 and P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C 8.68 3.62 0.001 0.999 5884 Pu-240)
U-233 (daughter for Am-241, Cm-P 1
S Truncated lognormal-n NUREG/CR-6697, Att. C 4.84 3.13 0.001 0.999 126 245, Np-237, and Pu-241)
U-234 (daughter for Cm-246 and Pu-P 1
S Truncated lognormal-n NUREG/CR-6697, Aft. C 4.84 3.13 0.001 0.999 126 238)
U-235 (daughter for Cm-243 and Pu-P 1
S Truncated lognormal-n NUREG/CR-6697, Aft. C 4.84 3.13 0.001 0.999 126 239)
U-236 (daughter for Cm-244 and Pu-P 1
S Truncated lognormal-n NUREG/CR-6697, Aft. C 4.84 3.13 0.001 0.999 126 240)
U-238 (daughter for Cm-246)
P 1
S Truncated lognormal-n NUREG/CR-6697, Att. C 4.84 3.13 0.001 0.999 126 Initial concentration of radionuclides P
3 D
0 Ground water initially NR NR NR NR present in groundwater (pCi/I) uncontaminated for this
_________________________________scenario Calculation Times I
sceari I_
I I
Time since placement of material (y)
P J
3 D
0 1NR NR NR NR Time for calculations (y)
P 3
D 0,1,3,10,30,100,300,1000 RESRAD Default NR NR NR NR Contaminated Zone Area of contaminated zone (M2
)
P 2
D 30,000 Site-specific: largest NR NR NR NR contiguous class 1/class 2 area (rounded to I_
nearest thousands)
II.BART LETT Page 9
Bartlett Engineering.
Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersd 1
2 3
4 Mean/
Median Thickness of contaminated zone (m)
P 2
D 2.67 7 51h percentile value -
applied to all ROCs except those listed below.
Site-specific distribution S
Uniform applied to Eu-152, Eu-0 154, and Nb-94 0.15 3.51 1.83 Length parallel to aquifer flow (m)
P 2
D 195 Site-specific - diameter of NR NR NR NR circle with an area of 30,000 m2 Contaminated fraction below water P
2 D
0 Ground water initially NR NR NR NR table uncontaminated for this scenario Cover and Contaminated Zone Hydrological Data Cover depth (m)
P 2
D 0
Site-specific - no cover NR NR NR NR assumed Density of contaminated zone (g/cm 3)
P 1
S Bounded Normal NUREG 6697 dist for site 1.5635 0.2385 0.827 2.3 1.5635 soil type - clay loam Contaminated zone erosion rate P
2 D
2.2E-3 Calculated value based NR NR NR NR (m/y) on site-specific slope of 6%
Contaminated zone total porosity P
2 S
Bounded Normal NUREG 6697 dist for site 0.41 0.09 0.1319 0.6881 0.41 soil type - clay loam Contaminated zone field capacity P
3 D
0.095 Calculated site-specific NR NR NR NR 0.095 value (ref. 3.1)
Contaminated zone hydraulic P
2 S
Bounded Log Normal n NUREG 6697 dist for site 1.36 2.17 0.00478 3190 3.90 conductivity (m/y) soil type - clay loam Contaminated zone b parameter P
2 S
Bounded Log Normal n NU REG 6697 dist for site 1.73 0.323 2.08 15.3 5.6 soil type - clay loam Humidity in air (g/m3)
P 3
D 8.2 Regional value for NR NR NR NR northern CA as represented by San Francisco Evapotranspiration coefficient P
2 S
Uniform NUREG/CR-6697 Att. C 0.5 0.75 NR NR 0.625 Average annual wind speed (m/s)
P 2
D 3.04 Site-specific value (from NR NR NR NR NCDC website) elBARTLETT Page 10
Bartlett Engineering.
Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parameters8 1
2 3
4 Mean/
I
_Median Precipitation (m/y)
P 2
D 0.91 Site-specific value from NR NR NR NR HB SAFSTOR Environmental Report, section 4.1.1 Irrigation (m/y)
B 3
S Uniform NUREG/CR-6697, Att C 0.36 0.76 NR NR 0.56 methodology Irrigation mode B
3 D
Overhead Overhead irrigation is NR NR NR NR common practice in U. S.
Runoff coefficient P
2 D
0.5 Site-specific value; NR NR NR NR NUREG/CR-6697, Att. C section 4.2 methodology Watershed area for nearby stream or P
3 D
2.52E+07 Site-specific value from NR NR NR NR pond (M2)
(HB SAFSTOR Environmental Report)
I Accuracy for water/soil computations 3
D 1.OOE-03 RESRAD Default NR NR NR NR Saturated Zone Hydrological Data Density of saturated zone (g/cm 3)
P 1
S Bounded Normal NUREG 6697 dist for site 1.5105 0.1855 0.937 2.084 1.5105 soil type - silty clay loam Saturated zone total porosity P
1 S
Bounded Normal NUREG 6697 dist for site 0.43 0.0699 0.214 0.646 0.43 soil type - silty clay loam Saturated zone effective porosity P
1 S
Bounded Normal NUREG 6697 dist for site 0.342 0.0705 0.124 0.56 0.342 soil type - silty clay loam Saturated zone field capacity P
3 D
0.088 Calculated site-specific NR NR NR NR 0.088 value (ref. 3.1)
Saturated zone hydraulic conductivity P
1 S
Bounded Log Normal n NUREG 6697 dist for site 0.362 1.59 0.0106 195 1.44 (m/y) soil type - silty clay loam Saturated zone hydraulic gradient P
2 D
0.002 Site-specific value NR NR NR NR determined using method described in NUREG/CR-6697, App. C (calculated in ref. 3.1)
Saturated zone b parameter P
2 S
Bounded NUREG 6697 dist for site 1.96 0.265 3.02 15.5 7.1 Log Normal n soil type - silty clay loam Water table drop rate (m/y)
P 3
D 1.OOE-03 RESRAD User Manual NR NR NR NR Well pump intake depth (m below P
2 S
Triangular NUREG/CR-6697, Att. C 6
10 30 10 water table)
Model: Nondispersion (ND) or Mass-P 3
D ND ND model recommended NR NR NR NR Balance (MB) for contaminant areas >
il 000 m 2 BARTLETT Page 11
Bartlett Engineering.
Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersd 1
2 3
4 Mean/
I
_Median Well pumping rate (m3/y)
P 2
S Uniform Min, Max, median value 1173 1973 1573 based on site irrigation and area and calculated according to NUREG/CR-6697, Att. C section 3.10 method. (calculated in ref. 3.1)
Unsaturated Zone Hydrological Data Number of unsaturated zone strata P
3 D
1 Site-specific value NR NR NR NR Unsat. zone thickness (m)
P 2
S Uniform Site-specific distribution 0.00 8.08 4.04 base on thickness of CZ and groundwater elevations Unsat. zone soil density (g/cm 3)
P 1
S Bounded Normal NUREG 6697 dist for site 1.5635 0.2385 0.827 2.3 1.5635 soil type - clay loam Unsat. zone total porosity P
2 S
Bounded Normal NUREG 6697 dist for site 0.41 0.09 0.1319 0.6881 -
0.41 soil type - clay loam Unsat. zone effective porosity P
1 S
Bounded Normal NUREG 6697 dist for site 0.315 0.0905 0.0349 0:594 0.315 soil type - clay loam Unsat. zone field capacity P
3 D
0.095 Site-specific value NR NR NR NR 0.095 (calculated in ref. 3.1)
Unsat. zone hydraulic conductivity P
1 S
Bounded Log Normal n NUREG 6697 dist for site 1.36 2.17 0.00478 3190 3.90 (m/y) soil type - clay loam Unsat. zone soil-specific b parameter P
2 S
Bounded NUREG 6697 dist for site 1.73 0.323 2.08 15.3 5.6 Log Normal n soil type - clay loam Occupancy Inhalation rate (m3/y)
B 3
D 8400 NUREG/CR-6697, Att C NR NR NR NR Mass loading for inhalation (g/m 3)
P 2
S Continuous linear NUREG/CR-6697, Att. C 2.33E-05 Exposure duration B
3 D
30 User's Manual for NR NR NR NR RESRAD Version 6; parameter value not used
,in dose calculation Iindoor dust filtration factor P
2S Uniform INUREG/CR-6697, Att. C 10.15 1
0.95 0.5 BARTLIETT Page 12
Bartlett Engineering.
Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersd 1
2 3
4 Mean/
Median Shielding factor, external gamma P
2 D
3.98E-01 7 5"h percentile value -
applied for Cm-243, Co-60, Cs-137, Eu-152, Eu-154, and Nb-94 NUREG/CR-6697, Att. C Bounded lognormal-n
- applied to all ROCs
-1.3 0.59 0,044 1
0.2725 except those listed above S
Fraction of time spent indoors B
3 D
0.6571 NUREG/CR-5512, Vol. 3 NR NR NR NR Table 6.87 Fraction of time spent outdoors (on B
3 D
0.1181 NUREG/CR-5512, Vol. 3 NR NR NR NR site)
Table 6.87 (outdoors +
gardening)
Shape factor flag, external gamma P
3 D
Circular Circular contaminated NR NR NR NR zone assumed for modeling purposes Ingestion, Dietary.
Fruits, vegetables, grain consumption B
2 D
112 NUREG/CR-5512, Vol. 3 NR NR NR NR (kg/y)
(other vegetables + fruits
+ grain)
Leafy vegetable consumption (kg/y)
B 3
D 21.4 NUREG/CR-5512, Vol. 3 NR NR NR NR Milk consumption (L/y)
B 2
D 233 NUREG/CR-5512, Vol. 3 NR NR NR NR Meat and poultry consumption (kg/y)
B 3
D 65.1 NUREG/CR5512, Vol. 3 NR NR NR NR (beef + poultry)
Fish consumption (kg/y)
B 3
D 20.6 NUREG/CR-5512, Vol. 3 NR NR NR NR Other seafood consumption (kg/y)
B 3
D 0.9 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Soil ingestion rate (g/y)
B 2
D 18.26 NUREG/CR-5512, Vol. 3 NR NR NR NR Drinking water intake (L/y)
B 2
D 511 NUREG/CR-5512, Vol. 3 NR NR NR NR Table 6.87 Contamination fraction of drinking P
3 0
1 All water assumed NR NR NR NR water contaminated Contamination fraction of household P
3 NA water (if used)
I I
I Contamination fraction of livestock P
3 0
1 All water assumed NR NR NR NR water
.contaminated I
BARTLETT Page 13
Bartlett Engineering.
Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersd 1
2 3
4 Mean/
Median Contamination fraction of irrigation P
3 D
1 AIII water assumed NR NR NR NR water contaminate Contamination fraction of aquatic P
2 D
1 NUREG/CR-5512, Vol. 3 NR NR NR NR food I
I II
_III__
_I Contamination fraction of plant food P
3 D
1 NUREG/CR-5512, Vol. 3 NR NR NR NR Contamination fraction of meat P
3 D
1 NUREG/CR-5512, Vol. 3 NR NR NR NR Contamination fraction of milk P
3 D
1 NUREG/CR-5512, Vol. 3 NR NR NR NR Ingestion, Non-Dietary Livestock fodder intake for meat M
3 D
27.1 NUREG/CR5512, Vol. 3 NR NR NR NR (kg/day)
Table 6.87, beef cattle +
poultry + layer hen Livestock fodder intake for milk M
3 D
63.2 NUREG/CR5512, Vol. 3 NR NR NR NR (kg/day)
Table 6.87, forage + grain
+ hay Livestock water intake for meat M
3 D
50.6 NUREG/CR5512, Vol. 3 NR NR NR NR (L/day)
Table 6.87, beef cattle +
poultry + layer hen Livestock water intake for milk M
3 D
60 NUREG/CR5512, Vol. 3 NR NR NR NR (L/day)
Table 6.87 Livestock soil intake (kg/day)
M 3
D 0.5 User's Manual for NR NR NR NR RESRAD Version 6, Appendix L Mass loading for foliar deposition P
3 D
4.OOE-04 NUREG/CR-5512, Vol. 3 NR NR NR NR (g/m
- 3)
Table 6.87, gardening Depth of soil mixing layer (m)
P 2
S Triangular NUREG/CR-6697, Att. C 0
0.15 0.6 0.23 Depth of roots (in)
P 1
D 1.22E+00 2 5th percentile value (Ref. 3.1) - applied to all ROCs except those listed below.
S Uniform NUREG/CR-6697, Att. C 0.3 4.0 2.15
- applied for Eu-152, Eu-154, and Nb-94 Drinking water fraction from ground P
3 D
1 All water assumed to be NR NR NR NR water supplied from groundwater Household water fraction from P
3 NA ground water (if used)
(0 BARTLETT Page 14
Bartlett Engineering.
Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersd 1
2 3
4 Mean/
Median Livestock water fraction from ground P
3 D
All water assumed to be NR NR NR NR water supplied from I_ _
_groundwater I
Irrigation fraction from ground water P
3 D
All water assumed to be NR NR NR NR supplied from
_groundwater Wet weight crop yield for Non-Leafy P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C 0.56 0.48 0.001 0.999 1.75 (kg /M2)
Wet weight crop yield for Leafy P
3 D
2.88921 NUREG/CR-5512, Vol. 3 NR NR NR NR (kg/m2)
Table 6.87 Wet weight crop yield for Fodder P
3 D
1.8868 NUREG/CR-5512, Vol. 3 NR NR NR NR (kg/m2)
Table 6.87 Growing Season for Non-Leafy (y)
P 3
D 0.246 NUREG/CR-5512, Vol. 3 NR NR NR NR Table 6.87 Growing Season for Leafy (y)
P 3
D 0.123 NUREG/CR-5512, Vol. 3 NR NR NR NR Table 6.87 Growing Season for Fodder (y)
P 3
D 0.082 NUREG/CR-5512, Vol. 3 NR NR NR NR Table 6.87 Translocation Factor for Non-Leafy P
3 D
0.1 NUREG/CR-5512, Vol. 3 NR NR NR NR Table 6.87 Translocation Factor for Leafy P
3 D
1 NUREG/CR-5512, Vol. 3 NR NR NR NR Table 6.87 Translocation Factor for Fodder P
3 D
1 NUREG/CR-5512, Vol. 3 NR NR NR NR Table 6.87 Weathering Removal Constant for P
2 S
Triangular NUREG/CR-6697, Att. C 5.1 18 84 33 Vegetation (l/y)
Wet Foliar Interception Fraction for P
3 D
0.35 NUREG/CR-5512, Vol. 3 NR NR NR NR Non-Leafy Table 6.87 Wet Foliar Interception Fraction for P
2 S
Triangular NUREG/CR-6697, Att. C 0.06 0.67 0.95 0.58 Leafy Wet Foliar Interception Fraction for P
3 D
0.35 NUREG/CR-5512, Vol. 3 NR NR NR NR Fodder Table 6.87 Dry Foliar Interception Fraction for P
3 D
0.35 NUREG/CR-5512, Vol. 3 NR NR NR NR Non-Leafy Table 6.87 Dry Foliar Interception Fraction for P
3 D
0.35 NUREG/CR-5512, Vol. 3 NR NR NR NR Leafy Dry Foliar Interception Fraction for P
3 D
0.35 NUREG/CR-5512, Vol. 3 NR NR NR NR SFodder IStorage times of contaminated foodstuffs (days):
BARTLETT Page 15
Bartlett Engineering.
Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersa 1
2 3
4 Mean/
Median Fruits, non-leafy vegetables, and B
3 D
14 NUREG/CR-5512, Vol. 3 NR NR NR NR grain Table 6.87 Leafy vegetables B
3 D
1 NUREG/CR-5512, Vol. 3 NR NR NR NR Table 6.87 Milk B
3 D
1 NUREG/CR-5512, Vol. 3 NR NR NR NR Table 6.87 Meat and poultry B
3 D
20 NUREG/CR-5512, Vol. 3 NR NR NR NR Table 6.87 (holdup period for beef)
Fish B
3 D
7 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Crustacea and mollusks B
3 0
7 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Well water B
3 0
1 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Surface water B
3 D
1 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Livestock fodder B
3 0
45 User's Manual for NR NR NR NR RESRAD Version 6,
]Appendix D Special Radionuclides (C-14)
C-12 concentration in water (g/cm 3)
P 3
D 2.OOE-05 User's Manual for NR NR NR NR RESRAD Version 6, Appendix L C-12 concentration in contaminated P
3 D
3.00E-02 User's Manual for NR NR NR NR soil (g/g)
RESRAD Version 6, Appendix L Fraction of vegetation carbon from P
3 D
2.OOE-02 User's Manual for NR NR NR NR soil RESRAD Version 6, Appendix L I
Fraction of vegetation carbon from P
3 D
9.80E-01 User's Manual for NR NR NR NR air RESRAD Version 6, Appendix L C-14 evasion layer thickness in soil P
2 0
4.27E-01 7 51h percentile value (IN)
BARTLETT Page 16
Bartlett Engineering.
Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersd 1
2 3
4 Mean/
Median C-14 evasion flux rate from soil P
3 D
7.00E-07 User's Manual for NR NR NR NR (1/sec)
RESRAD Version 6, Appendix L C-12 evasion flux rate from soil P
3 D
1.00E-10 User's Manual for NR NR NR NR (1 /sec)
RESRAD Version 6, Appendix L Fraction of grain in beef cattle feed B
3 D
0.2500 NUREG/CR-6697, Att. B NR NR NR NR Fraction of grain in milk cow feed B
3 D
0.1000 NUREG/CR-6697, Att. B NR NR NR NR Dose Conversion Factors (Inhalation mrem/pCi)
Ac-227 M
3 D
6.72E+00 FGR11 (RESRAD Dose NR NR NR NR Conversion Library)
Am-241 M
3 D
4.44E-01 FGR11 NR NR NR NR Am-243 M
3 D
4.40E-01 FGR11 NR NR NR NR C-14 M
3 D
2.09E-06 FGR11 NR NR NR NR Cm-243 M
3 D
3.07E-01 FGRI1 NR NR NR NR Cm-244 M
3 D
2.48E-01 FGR11 NR NR NR NR Cm-245 M
3 D
4.55E-01 FGR11 NR NR NR NR Cm-246 M
3 D
4.51 E-01 FGR11 NR NR NR NR Co-60 M
3 D
2.19E-04 FGR11 NR NR NR NR Cs-137 M
3 D
3.19E-05 FGR11 NR NR NR NR Eu-152 M
3 D
2.21E-04 FGR11 NR NR NR NR Eu-154 M
3 D
2.86E-04 FGR11 NR NR NR NR Gd-152 M
3 D
2.43E-01 FGR11 NR NR NR NR H-3 M
3 D
6.40E-08 FGR11 NR NR NR NR 1-129 M
3 D
1.74E-04 FGR11 NR NR NR NR Nb-94 M
3 D
4.14E-04 FGR11 NR NR NR NR Ni-59 M
3 D
2.70E-06 FGR11 NR NR NR NR Ni-63 M
3 D
6.29E-06 FGR11 NR NR NR NR Np-237 M
3 D
5.40E-01 FGR11 NR NR NR NR Pa-231 M
3 D
1.28E+00 FGR11 NR NR NR NR Pb-210 M
3 D
1.38E-02 FGR11 NR NR NR NR Po-210 M
3 D
9.40E-03 FGR11 NR NR NR NR 10BARTLETT Page 17
Bartlett Engineering.
Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersd 1
2 3
4 Mean/
M
.9E0 R
NR N
R Median Pu-238 M
3 D
3.92E-01 FGR11 NR NR NR NR Pu-239 M
3 D
4.29E-01 FGR11 NR NR NR NR Pu-240 M
3 D
4.29E-01 FGR11 NR NR NR NR Pu-241 M
.5-3FGR11 NP NR NR NR Pu-242 M
3 D
4.11_E-01 FGR11 NR NR NR NR Ra-226 M
3 D
8.59E-03 FGR1_1 NR NR NR NR Ra-228 M
3 D
5.08E-03 FGR1_1 NR NR NR NR Sr-90 M
3 D
1.31 E-03 FGR1 1 NR NR NR NR Tc-99 M
3 D
8.32E-06 FGR1_1 NR NR NR NR Th-228 M
3 D
3.43E-01 FGR11 NR NR NR NR Th-229 M
3 D
2.17E+00 FGR1 1 NR NR NR NR Th-230 M
3 D
3.26E-01 FGR1 1 NR NR NR NR Th232 M
3 D
1.64e+00 FGR1 1 NR NR NR NR U-233 M
3 D
1.35E-01 FGR11 NR NR NR NR U-234 M
3 D
1.32E-01 FGR1 1 NR NR NR NR U-235 M
3 D
1.23E-01 FGR11 NR NR NR NR U-236 M
3 D
1.25E-01 FGR11 NR NR NR NR U-238 M
3 D
1.18E-01 FGR11 NR NR NR NR Dose Conversion Factors (Ingestion mrem/pCi)
Ac-227 M
3 D
1.48E-02 FGR31 (RESRAD Dose NR NR NR NR Conversion Library)
Am-241 M
3 D
3.64E-03 FGR11 NR NR NR NR Am-243 M
3 D
3.62E-03 FGR1 1 NR NR NR NR C-14 M
3 D
2.09E-06 FGR1 1 NR NR NR NR Cm-243 M
3 D
2.51E-03 FGR11 NR NR NR NR Cm-244 M
3 D
2.02E-03 FGR1 1 NR NR NR NR Cm-245 M
3 D *3.74E-03 FGR1 1 NR NR NR NR Cm-246 M
3 D
3.70E-03 FGR1 1 NR NR NR NR Co-60 M
3 D
2.69E-05 FGR11 NR NR NR NR Cs-137 M
3 D
5.OOE-05 FGR11 NR NR NR NR Eu-152 M
3 D
6.48E-06 FGR11 NR NR NR NR Eu-154 M
3 D
9.55E-06 FGR11 NR NR NR NR (e BARTLETT Page 18
Bartlett Engineering.
Humboldt Bav Soil DCGLs ENG-HB-003 Rev. 0 Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersd 1
2 3
4 Mean/
Median Gd-152 M
3 D
1.61 E-04 FGR11 NR NR NR NR H-3 M
3 D
6.40E-08 FGR11 NR NR NR NR 1-129 M
3 D
2.76E-04 FGR11 NR NR NR NR Nb-94 M
3 D
7.14E-06 FGR11 NR NR NR NR Ni-59 M
3 D
2.10E-07 FGR11 NR NR NR NR Ni-63 M
3 D
5.77E-07 FGR11 NR NR NR NR Np-237 M
3 D
4.44E-03 FGR11 NR NR NR NR Pa-231 M
3 D
1.06E-02 FGR11 NR NR NR NR Pb-210 M
3 D
5.38E-03 FGR11 NR NR NR NR Po-210 M
3 D
1.90E-03 FGR11 NR NR NR NR Pu-238 M
3 D
3.20E-03 FGR11 NR NR NR NR Pu-239 M
3 D
3.54E-03 FGR11 NR NR NR NR Pu-240 M
3 D
3.54E-03 FGR11 NR NR NR NR Pu-241 M
3 D
6.84E-05 FGR11 NR NR NR NR Pu-242 M
3 D
3.36E-03 FGR11 NR NR NR NR Ra-226 M
3 D
1.32E-03 FGR11 NR NR NR NR Ra-228 M
3 D
1.44E-03 FGR11 NR NR NR NR Sr-90 M
3 D
1.53E-04 FGR11 NR NR NR NR Tc-99 M
3 D
1.46E-06 FGR11 NR NR NR NR Th-228 M
3 D
3.96E-04 FGRI1 NR NR NR NR Th-229 M
3 D
4.03E-03 FGR11 NR NR NR NR Th-230 M
3 D
5.48E-04 FGR11 NR NR NR NR Th-232 M
3 D
2.73E-03 FGR11 NR NR NR NR U-233 M
3 D
2.89E-04 FGR11 NR NR NR NR U-234 M
3 D
2.83E-04 FGR11 NR NR NR NR U-235 M
3 D
2.67E-04 FGR11 NR NR NR NR U-236 M
3 D
2.69E-04 FGR11 NR NR NR NR U-238 M
3 D
2.55E-04 FGR1 1 NR NR NR NR Plant Transfer Factors (pCi/g plant)/(pCi/g soil)
Ac-227 P
1 S
Truncated Iognormal-n NUREG/CR-6697, Att. C
-6.91 1.1 0.001 0.999 1.0E-03 Am-241 P
1 D
1.83E-03 7 5 th percentile value Am-243 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.91 0.9 0.001 0.999 1.0E-03 V,
BA RTLE:TT Page 19
Bartlett Engineering.
Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0
°d Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersd 1
2 3
4 Mean/
Median C-14 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-0.36 0.9 0.001 0.999 7.OE-01 Cm-243 P
1 S
1.83E-03 7 51h percentile value Cm -244 P
1 D
1.83E-03 7 5th percentile value Cm-245 P
1 D
1.83E-03 75th percentile value Cm-246 P
1 D
1.83E-03 7 51h percentile value Co-60 P
1 D
1.46E-01 7 51h percentile value Cs-137 P
1 D
7,82E-01 7 5th percentile value Eu-152 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.21 1.1 0.001 0.999 2.0E-03 Eu-154 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.21 1.1 0.001 0.999 2.0E-03 Gd-152 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.21 1.1 0.001 0.999 2.0E-03 H-3 P
1 S
Truncated Iognormal-n NUREG/CR-6697, Att. C 1.57 1.1 0.001 0.999 4.8E+00 1-129 P
1 D
3.67E-02 75th percentile value Nb-94 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-4.61 1.1 0.001 0.999 1.OE-02 Ni-59 P
1 D
9.12E-02 751h percentile value Ni-63 P
1 D
9.12E-02 751h percentile value Np-237 P
1 D
3.67E-02 75th percentile value Pa-231 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-4.61 1.1 0.001 0.999 1.0E-02 Pb-210 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-5.52 0.9 0.001 0.999 4.0E-03 Po-210 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.90 0.9 0.001 0.999 1.0E-03 Pu-238 P
1 D
1.83E-03 751h percentile value Pu-239 P
1 D
1.83E-03 75th percentile value Pu-240 P
1 D
1.83E-03 751h percentile value Pu-241 P
1 D
1.83E-03 7 5 1h percentile value Pu-242 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.91 0.9 0.001 0.999 1.0E-03 Ra-226 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-3.22 0.9 0.001 0.999 4.0E-02 Ra-228 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-3.22 0.9 0.001 0.999 4.0E-02 Sr-90 P
1 D
5.90E-01 7 5 th percentile value Tc-99 P
1 D
.9.16E+00 7 5 1h percentile value Th-228 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.91 0.9 0.001 0.999 1.0E-03 Th-229 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.91 0.9 0.001 0.999 1.0E-03 Th-230 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.91 0.9 0.001 0.999 1.0E-03 Th-232 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.91 0.9 0.001 0.999 1.0E-03 B A BARTLETT Page 20
Bartlett Engineering.
Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersd 1
2 3
4 Mean/
Median U-233 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.21 0.9 0.001 0.999 2.OE-03 U-234 P
1 S
Truncated lognormal-n NUREG/CR-6697, Art. C
-6.21 0.9 0.001 0.999 2.0E-03 U-235 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.21 0.9 0.001 0.999 2.OE-03 U-236 P
1 S
Truncated lognormal-n NUREG/CR-6697, Art. C
-6.21 0.9 0.001 0.999 2.OE-03 U-238 P
1 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.21 0.9 0.001 0.999 2.0E-03 Meat Transfer Factors (pCi/kg)I(pCi/d)
Ac-227 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-10.82 1.0 0.001 0.999 2.OE-05 Am-241 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-9.90 0.2 0.001 0.999 5.OE-05 Am-243 P
2 S
Truncated Iognormal-n NUREG/CR-6697, Att. C
-9.90 0.2 0.001 0.999 5.OE-05 C-14 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-3.47 1.0 0.001 0.999 3.1 E-02 Cm-243 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-10.82 1.0 0.001 0.999 2.OE-05 Cm-244 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-10.82 1.0 0.001 0.999 2.OE-05 Cm-245 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-10.82 1.0 0.001 0.999 2.OE-05 Cm-246 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-10.82 1.0 0.001 0.999 2.OE-05 Co-60 P
2 D
5.86E-02 75h percentile value Cs-137 P
2 D
6.52E-02 75__h percentile value Eu-152 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.21 1.0 0.001 0.999 2.OE-03 Eu-1 54 P
2 S
Truncated lognorrnal-n NUREG/CR-6697, Att. C
-6.21 1.0 0.001 0.999 2.OE-03 Gd-152 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.21 1.0 0.001 0.999 2.OE-03 H-3 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-4.42 1.0 0.001 0.999 1.2E-02 1-129 P
2 D
5.23E-02 7 51h percentile value Nb-94 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-13.82 0.9 0.001 0.999 1.OE-06 Ni-59 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-5.30 0.9 0.001 0.999 5.OE-03 Ni-63 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-5.30 0.9 0.001 0.999 5.OE-03 Np-237 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.91 0.7 0.001 0.999 1.OE-03 Pa-231 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-12.21 1.0 0.001 0.999 5.OE-06 Po-210 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-5.30 0.7 0.001 0.999 5.OE-03 Pb-210 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-7.13 0.7 0.001 0.999 8.OE-04 Pu-238 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-9.21 0.2 0.001 0.999 1.OE-04 Pu-239 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-9.21 0.2 0.001 0.999 1.OE-04 Pu-240 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-9.21 0.2 0.001 0.999 1.OE-04 Pu-241 P
2 S
Truncated Iognormal-n NUREG/CR-6697, Att. C
-9.21 0.2 0.001 0.999 1M.E-04 BARTLETT Page 21
Bartlett Engineering.
Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersd 1
2 3
4 Mean/
Median Pu-242 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-9.21 0.2 0.001 0.999 1.OE-04 Ra-226 P
2 S
Truncated Iognormal-n NUREG/CR-6697, Att. C
-6.91 0.7 0.001 0.999 1.0E-03 Ra-228 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.91 0.7 0.001 0.999 1.OE-03 Sr-90 P
2 S
Truncated Iognormal-n NUREG/CR-6697, Att. C
-4.61 0.4 0.001 0.999 1.OE-02 Tc-99 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-9.21 0.7 0.001 0.999 1.OE-04 Th-228 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-9.21 1.0 0.001 0.999 1.OE-04 Th-229 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-9.21 1.0 0.001 0.999 1.OE-04 Th-230 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-9.21 1.0 0.001 0.999 1.OE-04 Th-232 P
2 S
Truncated Iognormal-n NUREG/CR-6697, Att. C
-9.21 1.0 0.001 0.999 1.OE-04 U-233 P
2 S
Truncated Iognormal-n NUREG/CR-6697, Att. C
-7.13 0.7 0.001 0.999 8.OE-04 U-234 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-7.13 0.7 0.001 0.999 8.OE-04 U-235 P
2 S
Truncated Iognormal-n NUREG/CR-6697, Att. C
-7.13 0.7 0.001 0.999 8.OE-04 U-236 P
2 S
Truncated Iognormal-n NUREG/CR-6697, Att. C
-7.13 0.7 0.001 0.999 8.OE-04 U-238 P
2 S
Truncated Iognormal-n NUREG/CR-6697, Att. C
-7.13 0.7 0.001 0.999 8.OE-04 Milk Transfer Factors (pCi/L)/(pCi/d)
Ae-227 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-13.12 0.9 0.001 0.999 2.OE-06 Am-241 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-13.12 0.7 0.001 0.999 2.OE-06 Am-243 P
2 S
Truncated Iognormal-n NUREG/CR-6697, Att. C
-13.12 0.7 0.001 0.999 2.OE-06 C-14 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-4.4 0.9 0.001 0.999 1.2E-02 Cm-243 P
2 S
Truncated Iognormal-n NUREG/CR-6697, Att. C
-13.12 0.9 0.001 0.999 2.OE-06 Cm-244 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-13.12 0.9 0.001 0.999 2.OE-06 Cm-245 P
2 S
Truncated Iognormal-n NUREG/CR-6697, Att. C
-13.12 0.9 0.001 0.999 2.OE-06 Cm-246 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-13.12 0.9 0.001 0.999 2.OE-06 Co-60 P
2 S
Truncated Iognormal-n NUREG/CR-6697, Att. C
-6.21 0.7 0.001 0.999 2.OE-03 Cs-1 37 P
2 D
1.39E-02 7 5th percentile value Eu-1 52 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-9.72 0.9 0.001 0.999 6.OE-05 Eu-1 54 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-9.72 0.9 0.001 0.999 6.OE-05 Gd-152 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-9.72 0.9 0.001 0.999 6.OE-05 H-3 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-4.6 0.9 0.001 0.999 1.OE-02 1-129 P
2 D
1.39E-02 7 51h percentile value Nb-94 P
2 S
Truncated iognormal-n NUREG/CR-6697, Att. C
-13.12 0.7 0.001 0.999 2.OE-06 OF BARTLETT Page 22
Bartlett Engineering.
Humboldt Bav Soil DCGLs ENG-HB-003 Rev. 0 Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersd 1
2 3
4 Mean/
I
_Median Ni-59 P
2 D
3.21 E-02 7 51h percentile value Ni-63 P
2 D
3.21 E-02 7 51h percentile value Np-237 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-11.51 0.7 0.001 0.999 1.0E-05 '
Pa-231 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-12.21 0.9 0.001 0.999 5.0E-06 Po-210 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-7.82 0.7 0.001 0999-
-4.0E-04 Pb-210 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-8.11 0.9 0.001 0.999 3.0E-04 Pu-238 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-13.82 0.5 0.001 0.999 1.OE-06 Pu-239 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-13.82 0.5 0.001 0.999 1.OE-06 Pu-240 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-13.82 0.5 0.001 0.999 1.aE-06 Pu-241 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-13.82 0.5 0.001 0.999 1.OE-06 Pu-242 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-13.82 0.5 0.001 0.999 1.OE-06 Ra-226 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.91 0.5 0.001 0.999 1.OE-03 Ra-228 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.91 0.5 0.001 0.999 1.OE-03 Sr-90 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.21 0.5 0.001 0.999 2.OE-03 Tc-99 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-6.91 0.7 0.001 0.999 1.OE-03 Th-228 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-12.21 0.9 0.001 0.999 5.OE-06 Th-229 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-12.21 0.9 0.001 0.999 5.OE-06 Th-230 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-12.21 0.9 0.001 0.999 5.OE-06 Th-232 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-12.21 0.9 0.001 0.999 5.OE-06 U-233 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-7.82 0.6 0.001 0.999 4.OE-04 U-234 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-7.82 0.6 0.001 0.999 4.OE-04 U-235 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-7.82 0.6 0.001 0.999 4.OE-04 U-236 P
2 S
Truncated lognormal-n NUREG/CR-6697, Att. C
-7.82 0.6 0.001 0.999 4.OE-04 U-238 P
S Truncated lognormal-n NUREG/CR-6697, Att. C
-7.82 0.6 0.001 0.999 4.OE-04 Bioaccumulation Factors for Fish ((pCi/kg)/(pCi/L))
Ac-227 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 2.7 1.1 1.5E+01 Am-241 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 3.4 1.1 3.OE+01 Am-243 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 3.4 1.1 3.OE+01 C-14 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 10.8 1.1 4.9E+04 Cm-243 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 3.4 1.1 3.OE+01 Cm-244 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 3.4 1.1 3.OE+01 Cm-245 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 3.4 1.1 3.OE+01 BARTLETT Page 23
Bartlett Engineering.
Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersd 1
2 3
4 Mean/
Median Cm-246 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 3.4 1.1 3.OE+01 Co-60 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 5.7 1.1 3.OE+02 Cs-137 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 7.6 0.7 2.0E+03 Eu-152 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 3.9 1.1 4.9E+01 Eu-1 54 P
2 S
Lognormal-n NUREG/CR-6697, Aft. C 3.9 1.1 4.9E+01 Gd-152 P
2 S
Lognormal-n NUREG/CR-6697, Aft. C 3.2 1.1 2.5E+01 H-3 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 0
0.1 1.0E+00 1-129 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 3.7 1.1 4.0E+01 Nb-94 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 5.7 1.1 3.0E+02 Ni-59 P
2 S
Lognormal-n NUREG/CR-6697, Aft. C 4.6 1.1 9.9E+01 Ni-63 P
2 S
Lognormal-n NUREG/CR-6697, Alt. C 4.6 1.1 9.9E+01 Np-237 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 3.4 1.1 3.0E+01 Pa-231 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 2.3 1.1 9.9E+00 Po-210 P
2 S
Lognormal-n NUREG/CR-6697, Aft. C 4.6 1.1 1.0E+01 Pb-210 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 5.7 1.1 3.0E+02 Pu-238 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 3.4 1.1 3.0E+01 Pu-239 P
2 S
Lognormal-n NUREG/CR-6697, Alt. C 3.4 1.1 3.0E+01 Pu-240 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 3.4 1.1 3.0E+01 Pu-241 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 3.4 1.1 3.OE+01 Pu-242 P
2 S
Lognormal-n NUREG/CR-6697, Alt. C 3.4 1.1 3.OE+01 Ra-226 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 3.9 1.1 4.9E+01 Ra-228 P
2 S
Lognormal-n NUREG/CR-6697, Alt. C 3.9 1.1 4.9E+01 Sr-90 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 4.1 1.1 6.OE+01 Tc-99 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 3
1.1 2.0E+01 Th-228 P
2 S
Lognormal-n NUREG/CR-6697, Alt. C 4.6 1.1 9.9E+01 Th-229 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 4.6 1.1 9.9E+01 Th-230 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 4.6 1.1 9.9E+01 Th-232 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 4.6 1.1 9.9E+01 U-233 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 2.3 1.1 1.0E+01 U-234 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 2.3 1.1 1.OE+01 U-235 P
2 S
Lognormal-n NUREG/CR-6697, Alt. C 2.3 1.1 1.0E+01 U-236 P
2 S
Lognormal-n NUREG/CR-6697, Alt. C 2.3 1.1 1.0E+01 BARTLETT Page 24
Bartlett Engineering.
Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersd 1
2 3
4 Mean/
Median U-238 P
2 S
Lognormal-n NUREG/CR-6697, Att. C 2.3 1.1 1.0E+01 Bioaccumulation Factors for Crustacea/ Mollusks ((pCi/kg)/(pCi/L))
Ac-227 P
3 D
1.OOE+03 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Am-241 P
3 D
1.OOE+03 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Am-243 P
3 D
1.OOE+03 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D C-14 P
3 D
9.1OE+03 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Cm-243 P
3 0
1.OOE+03 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Cm-244 P
3 0
1.OOE+03 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Cm-245 P
3 D
1.OOE+03 User's Manual for NR.
NR NR NR RESRAD Version 6, Appendix D Cm-246 P
3 D
1.OOE+03 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Co-60 P
3 D
2.OOE+02 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Cs-137 P
3 0
1.OOE+02 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Eu-152 P
3 0
1.OOE+03 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Eu-154 P
3 0
1.OOE+03 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Gd-152 P
3 D
1.OOE+03 User's Manual for NR NR NR NR RESRAD Version 6, 1
1 lAppendix D (gN 9ART"LETT Page 25
Bartlett Engineering.
Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersd 1
2 3
4 Mean/
Median H-3 p
3 D
1.OOE+00 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D 1-129 P
3 D
5.0OE+00 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Nb-94 p
3 D
1.OOE+02 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Ni-59 P
3 D
1.OOE+02 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Ni-63 p
3 D
1.OOE+02 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Np-237 p
3 D
4.OOE+02 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Pa-231 p
3 D
1.10E+02 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Pb-210 p
3 D
1.OOE+02 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Po-210 p
3 D
2.OOE+04 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Pu-238 p
3 0
1.OOE+02 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Pu-239 p
3 D
1.OOE+02 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Pu-240 p
3 D
1.OOE+02 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Pu-241 p
3 0
1.OOE+02 User's Manual for NR NR NR NR RESRAD Version 6, I
I I
Appendix D Pu-242 P
3D1.00E+02 User's Manual for NR NRNR NR RESRAD Version 6, iAppendix D e BARTLETT Page 26
Bartlett Engineering.
Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersd 1
2 3
4 Mean/
Median Ra-226 P
3 D
2.50E+02 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Ra-228 P
3 D
2.50E+02 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Sr-90 P
3 D
1.OOE+02 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Tc-99 P
3 D
5.OOE+00 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Th-228 P
3 D
5.OOE+02 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Th-229 P
3 D
5.OOE+02 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Th-230 P
3 D
5.OOE+02 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D Th-232 P
3 0
5.OOE+02 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D U-233 P
3 0
6.OOE+01 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D U-234 P
3 0
6.OOE+01 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D U-235 P
3 D
6.OOE+01 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D U-236 P
3 0
6.OOE+01 User's Manual for NR NR NR NR RESRAD Version 6, Appendix D U-238 P
3 0
6.OOE+01 User's Manual for NR NR NR NR RESRAD Version 6, 1
lAppendix D Graphics Parameters Number of points 1
32 RESRAD Default NR NR NR NR
'&%BARTLETT Page 27
Bartlett Engineering.
Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersd 1
2 3
4 Mean/
Median Spacing log RESRAD Default NR NR NR NR Time integration parameters Maximum number of points for dose 17 RESRAD Default NR NR NR NR Table 1 Notes:
a b
C d
P = physical, B = behavioral, M = metabolic; (see NUREG/CR-6697, Attachment B, Table 4.)
1 = high-priority parameter, 2 = medium-priority parameter; 3 = low-priority parameter (see NUREG/CR-6697, Attachment B, Table 4.1)
D = deterministic, S = stochastic Distributions Statistical Parameters:
Lognormal-n: 1= mean, 2 = standard deviation Bounded lognormal-n: 1=mean, 2 = standard deviation, 3 = minimum, 4 = maximum Truncated lognormal-n: 1 = mean, 2 = standard deviation, 3 = lower quantile, 4 = upper quantile Bounded normal: 1 = mean, 2 = standard deviation, 3 = minimum, 4 = maximum Triangular: 1 = minimum, 2 = mode, 3 = maximum Uniform: 1 = minimum, 2 = maximum BARTLETT Page 28
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Table 3: RESRAD 6.5 Generated POM Doses and DCGL Values by ROC POM Dose DCGL ROC (mrem/y)
(pCi/g)
Am-241 9.68E-01 2.58E+01 C-14 3.97E+00 6.30E+00 Cm-243 8.61 E-01 2.90E+01 Cm-244 5.20E-01 4.81 E+01 Cm-245 1.41 E+00 1.78E+01 Cm-246 9.70E-01 2.58E+01 Co-60 6.55E+00 3.82E+00 Cs-137 3.15E+00 7.93E+00 Eu-152 2.48E+00 1.01 E+01 Eu-154 2.66E+00 9.40E+00 H-3 3.65E-02 6.86E+02 1-129 5.17E+00 4.83E+00 Nb-94 3.51 E+00 7.13E+00 Ni-59 1.27E-02 1.97E+03 Ni-63 3.45E-02 7.24E+02 Np-237 2.25E+01 1.11E+00 Pu238 8.43E-01 2.97E+01 Pu239 9.36E-01 2.67E+01 Pu240 9.36E-01 2.67E+01 Pu241 2.90E-02 8.61 E+02 Sr-90 1.66E+01 1.51 E+00 Tc-99 2.02E+00 1.24E+01 L
BARTLETT Page 29
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Table 4: Soil DCGLI Values by Radionuclide DCGL ROC (pCi/g)
Am-241 2.5E+01 C-14 6.3E+00 Cm-243 2.9E+01 Cm-244 4.8E+01 Cm-245 1.7E+01 Cm-246 2.5E+01 Co-60 3.8E+00 Cs -137 7.9E+00 Eu-152 1.OE+01 Eu-154 9.4E+00 H-3 6.8E+02 1-129 4.8E+00 Nb-94 7.1 E+00 Ni-59 1.9E+03 Ni-63 7.2E+02 Np-237 1.1 E+00 Pu238 2.9E+01 Pu239 2.6E+01 Pu240 2.6E+01 Pu241 8.6E+02 Sr-90 1.5E+00 Tc-99 1.2E+01 BARTLETT Page 30
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Appendix A Selected Pages from RESRAD Code Executions BARTLETT Page 31
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 Am-241 Results:
- IRESRAD, Version 6.5 T" Limit - 30 days 11/26/2011 12:36 Page I
Summary.
HR soil DCGL.Am241 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\AM241LDCGL\\HB SOIL DCGLAM241.RAD Table of Contents Part I:
Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary...
2 Site-Specific Parameter Summary............................
4 Summary of Pathway Selections..............................
8 Contaminated Zone and Total Dose Summary...................
9 Total Dose Components Time = 0.000E+0O.....................................
10 Time = 1.000E+00.....................................
11 Time = 3.000E+00.....................................
12 Time = 1.OOOE+01....................................
13 Time = 3.000E+01.....................................
14 Time = 1.000E+02.....................................
15 Time = 3.OOOE+02.....................................
16 Time = 1.000E+03....................................
17 Dose/Source Ratios Summed Over All Pathways...............
18 Single Radionuclide Soil Guidelines.......................
18 Dose Per Nuclide Summed Over All Pathways.................
19 Soil Concentration Per Nuclide............................
19 1RESRAD, Version 6.5 To Limit = 30 days 11/26/2011 12:36 Page 2
Summary : HE soil DCGLAm241 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILIS\\AM241LDCGL\\HB SOIL DCGLAM241.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: HR DCGLs Plus FGR 12 & FGR 11 0
3 Current Base 3
Parameter Menu P
.arm r
value#
C ase*
Name A-1 I DCFs for external ground radiation, (mrem/yr)/(pCi/g)
A-1 AC-225 (Source:
FGR 12) 6.371E-02 6.371E-02 DCFi(
1)
A-1I Am-241 (Source: FGR 12) 4.372E-02 4.372E-02 DCFi(
2)
A-i At-217 (Source: FGR 12) 1.773E-03 1.773E-03 DCF1(
3)
A-i Bi-213 (Source:
FGR 12) 7.660E-01 7.660r-01 DCF1(
4)
A-i Fr-221 (Source:
FGR 12) 1.536E-01 1.536E-01 3 DCFi(
5)
A-i Np-237 (Source: FGR 12) 7.790E-02 7.790E-02 DCF1(
6)
A-I Pa-233 (Source: FGR 12) 1.020E+00 1.020E+00 DCF1(
7)
A-1 Pb-209 (Source:
FGR 12) 7.734E-04 7.734E-04 DCFi(
8)
A-1 Po-213 (Source: FGR 12)
O.O00E+00 0.OOOE+00 DCF1(
9)
A-1 Ra-225 (Source: FGR 12) 1.102E-02 1.102E-02 DCF1( 10)
A-I Th-229 (Source: FGR 12) 3.213E-01 3.213E-01 DCF1( 11)
A-I Tl-209 (Source:
FGR 12) 1.293E+01 1.293E+01 DCFi(
12)
A-1 u-233 (Source: FGR 12) 1.397E-03 1.397E-03 DCF1( 13)
B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Am-241 4.440E-01 4.440E-01 DCF2(
1)
B-I Np-237+D 5.400E-01 5.400E-01 DCF2(
2)
B-I h-229+D 2.169E+00 2.150E+00 DCF2(
3)
B-I u-233 1.350E-01 1.350E-01 DCF2(
4)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Am-241 3.640E-03 3.640E-03 DCF3(
1)
D-1 Np-237+D 4.444E-03 4.440E-03 DCF3(
2)
D-1 Th-229+D 4.027E-03 3.530E-03 DCF3(
3) o-1 u-233 2.890E-04 2.890E-04 DCF3(
4)
D-34 Food transfer factors:
D-34 Am-241 plant/soil concentration ratio, dimensionless 1.830E-03 1.000E-03 RTF(
1,1)
D-34 Am-241 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.000E-O5 5.OOOE-050- RTF(
1,2)
D-34 Am-241 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.000E-06 2.000E-06 RTF(
1,3)
D-34 D-34 Np-237+D plant/soil concentration ratio, dimensionless 3.670E-02 2.000E-02 RTF(
2,1)
D-34 3 Np-237+D beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-03 1.000E-03 RTF(
2,2)
D-34 Np-237+D milk/livestock-intake ratio, (pCi/L)/(pCi/d) 5.000E-06 5.000E-06 RTF(
2,3)
D-34 3
D-34 Th-229+D
, plant/soil concentration ratio, dimensionless 1.000E-03 1.O00E-03 RTF(
3,1)
D-34 Th-229+D beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-04 1.000E-04 RTF(
3,2)
D-34 Th-229+D milk/livestock-intake ratio, (pCi/L)/(pci/d) 5.000E-06 5.000E-06 RTF(
3,3)
D-34 D-34 I u-233
, plant/soil concentration ratio, dimensionless 2.500E-03 2.500E-03 RTF(
4,1)
D-34 u-233 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 3.400E-04 3.400E-04 RTF(
4,2)
D-34 u-233 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 6.000E-04 6.000E-04 RTF(
4,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Am-241
, fish 3.000E+01 3.0OOE+01 BIOFAC(
1,1)
D-5 Am-241
- crustacea and mollusks 1.000E+03 1.000E+03 BIOFAC(
1,2)
D-5 3
o-5 Np-237+D
, fish 3.000E+01 3.0OOE+01 BIOFAC(
2,1)
D-5 Np-237+D
, crustacea and mollusks 4.000E+02 4.000E+02 BIOFAC(
2,2)
IRESRAD, Version 6.5 To Limit = 30 days 11/26/2011 12:36 Page 3
Summary : HB soil DCGLAm241 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\AM24L.DCGL\\HB SOIL DCGLAM241.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)
Dose Library: HR DCGLs Plus FGR 12 & FGR 11 0
3 Current I
Base Parameter Menu 3 Parameter value#
I Cast* 3*Name D-5
- Th-229+D
, fish 1.000E+02 I 1.0OOE+02 3 BIOFAC(
3,1)
D-5 3 Th-229+D
, crustacea and mollusks 5.OO0E+02 5.000E+02 BIOFAC(
3,2)
D-5 I
D-5 I u-233
, fish 1.000E+01 1.OOOE+01 3 BIOFAC(
4,1)
D-S u-233
, crustacea and mollusks 6.000E+01 6.000E+O1 BIOFAC(
4,2)
- For DCF1(xxx) only, factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Default.Lib W/o Associate Nuclide contributions.
t EBARTLETT Page 32
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 IRESRAD, Version 6.5 T< Limit = 30 days 11/26/2011 12:36 Page 4
Summary : HR soil DCGL_Am241 File C:\\RESRAD.FAMILY\\RESRAD\\6.S\\USERFILES\\Am24LDCGL\\HB SOIL DCGLAM241.RAD Site-Specific Parameter Summary 0
3 Menu 3Parameter ROll Area of contaminated zone (m**2)
ROll Thickness of contaminated zone (m)
ROll Fraction of contamination that is submerged R011 Length parallel to aquifer flow (m)
ROll Basic radiation dose limit (mrem/yr)
RO11 Time since placement of material (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
Roll Times for calculations (yr)
R012 Initial principal radionuclide (pCi/g):
Am-241 R012 Concentration in groundwater CpCi/L):
Am-241 R013 Cover depth (m)
R013 Density of cover material (g/cm 0*3)
R013 Cover depth erosion rate (m/yr)
R013 Density of contaminated zone (g/cm**3)
R013 Contaminated zone erosion rate (m/yr)
R013 Contaminated zone total porosity R013 Contaminated zone field capacity R013 Contaminated zone hydraulic conductivity (m/yr)
R013 Contaminated zone b parameter R013 Average annual wind speed (m/sec)
R013 Humidity in air (g/m**3)
ROl3 Evapotranspi ration coefficient R013 Precipitation (m/yr)
R013 Irrigation (m/yr) eOI3 Irrigation mode R013 Runoff coefficient R013 watershed area for nearby stream or pond (m**2)
ROl3 Accuracy for water/soil computations R014 Density of saturated zone (g/c m*3)
R014 Saturated zone total porosity R014 Saturated zone effective porosity R014 Saturated zone field capacity R014 Saturated zone hydraulic conductivity (m/yr)
R014 Saturated zone hydraulic gradient R014 Saturated zone b parameter R014 water table drop rate (m/yr)
R014 well pump intake depth (m below water table)
R014 Model: Nondispersion (ND) or Mass-Balance (MB)
R014 well pumping rate (m**3/yr) user u
a Used by RESRAD I Parameter Input 3.Default C..If different from user input).
Name 3.OOOE+04 1.OOOE+04 2.670E+00 2.OOOE+O0 O.OOOE+00 O.OOOE+O0 1.950E+02 l.O00E+02 2.500E+01 3.OOOE+O1 O.OOOE+O0 O.OOOE+00 1.OOOE+O0 l.O00E+03 3.0OOE+O0 3.00OE+O0 1.O00E+O l.OOOE+01 3.OOOE+Ol 3.OOOE+01 l.O00E+02 l.OOOE+02 3.OOOE+02 3.OOOE+02 l.O00E+03 1.O00OE+03 not used O.O00OE+0O not used O.OOOE+O0 3 1.OOOE+O0 O.OOOE+O0 not used O.OOOE+00 O.OOOE+OO O.OOOE+O0 not used 1.500E+00 not used 1.OOOE-O3 1.564E+00 1.SOOE+O0 2.200E-03 1.OOOE-03 4.100E-01 4.OOOE-01 3 9.500E-02 2.OOOE-01 3.900E+00 1.000E+O1 5.600E+O0 5.300E+00 3.040E+00 2.OOOE+00 not used 8.OOOE+00 6.250E-01 5.OOOE-Ol 9.100E-Ol 1.OOOE+O0 5.600E-01 2.ODOE-Ol overhead overhead 5.000E-Ol 2.OOOE-Ol 2.520E+07 l.OOOE+06 l.OOOE-03 l.O00E-03 1.510E+O0 1.500E+O0 4.300E-01 4.OOOE-Ol I 3.420E-01 2.OOOE-Ol 8.80OE-02 2.OOOE-0l I 2.880E+01 1.OOOE+02 2.OOOE-03 2.OOOE-02 7.100E+O0 5.300E+00 l.O00E-03 1.OOOE-03 l.OOOE+01 l.OOE+O1 ND NO 1.573E+03 2.500E+02 IRESRAD, Version 6.5 T' Limit = 30 days 11/26/2011 12:36 Page 5
Summary : HE soil DCGL_Am241 File
- C:\\RESRAILFAMILY\\RESRAD\\6.5\\USERFILES\\Am241LDCGL\\HB SOIL DCGLAM241.RAD Site-Specific Parameter Summary (continued) 0 User I
menu Parameter input Default Cif R015 Number of unsaturated zone strata 1
1 R015 Unsat. zone 1, thickness (m) 4.040E+00 4.OOOE+00 RO5 Unsat. zone 1, soil density (g/cm**3) 1.564E+00 1.500E+00 R015 Unsat. zone 1, total porosity 4.100E-01 4.OOOE-01 ROI5 Unsat. zone 1, effective porosity 3.150E-01 2.OOOE-01 R0I5 Unsat.
zone 1, field capacity 9.500E-02 2.OOOE-01 R015 Unsat. zone 1, soil-specific b parameter 3.600E+00 5.300E+00 RO15 Unsat. zone 1, hydraulic conductivity (m/yr) 3.900E+00 1.000E+1O1 R016 Distribution coefficients for Am-241 R016 Contaminated zone (cm'"3/g) 1.445E+03 2.OOOE+01 R016 Unsaturated zone 1 (cm**3/g) 1.445E+03 2.000E+Ol R016 Saturated zone (cm**3/g) 1.445E+03 2.OOOE+OI R016 Leach rate (/yr)
O.O00E+00 O.OOOE+00 R016 solubility constant O.OOOE+O0 O.OOOE+00 R016 Distribution coefficients for daughter Np-237 R016 Contaminated zone (cm**3/g) 1.700E+01 3-1.OOOE+00 R016 Unsaturated zone 1 (cm**3/g) 1.700E+01 '-1.00OE+00 R016 Saturated zone (cm**3/g) 1.700E+01 '-I.OOOE+OO R016 Leach rate (/yr)
O.OOOE+00 O.OOOE+OO R016 Solubility constant O.OOOE+00 O.OOOE+OO R016 Distribution coefficients for daughter Th-229 R016 Contaminated zone (cm**3/g) 5.884E+03 6.OOOE+04 RO16 Unsaturated zone 1 (cm**3/g) 3 5.884E+03 6.OOOE+04 R016 Saturated zone (cm**3/g)
I 5.884E+03 3 6.OOOE+04 R016 Leach rate (/yr)
O..000E+O0 O.O00E+OO R0I6 Solubility constant O.O0OE+O0 O.O00oE+OO R016 Distribution coefficients for daughter U-233 R016 Contaminated zone (cm*3/g) 1.260E+02 5.000E+01 R016 Unsaturated zone I (cm**3/g) 1.260E+02 5.000E+01 R016 Saturated zone (cmt*3/g) 1.260E+02 5.OOOE+O1 R016 Leach rate C/yr)
O.OOOE+O0 O.OOOE+00 R016 Solubility constant O.OO00E+04 O.OOOE+00 R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 R017 Mass loading for inhalation (g/m**3) 1.OOOE-04 1.OOOE-04 R017 Exposure duration 3.OOOE+01 3.OOOE+01 R017 Shielding factor, inhalation 5.S00E-01 4.OOOE-01 R017 Shielding factor, external ganma 2.725E-01 7.OOOE-01 R017 Fraction of time spent indoors 6.571E-01 5.OOOE-01 1BARTLETT AREA THICKO SUBMFRACT 3 LCZPAQ 3 BRDL
' TI 3 T(
2) 3 T(
3)
T( 4)
T( 5)
T( 6) 3 T(
7) 3 T(
8)
T(
9)
T(10) 3 Sl~l)
W1( 1)
SwiC(1)
COVERO 3 DENSCV VCV 3 DENSCZ I VCZ TPCZ FCCZ HCCZ BCZ WIND HUMID EVAPTR PRECIP RI IDITCH RUNOFF WAREA EPS 3 DENSAQ TPSZ EPSZ
' FCSZ 3 HCSZ HGWT BSZ 3VW'T 3 DWIBWT MODEL 3UW Parameter Name NS HM1 DENSUZ(1)
TPUZ(1)
EPUZ(1)
FCUZ(1)
BUZ(1) 3 HCUZ(1)
DCNUCCC 1)
DCNUCU( 1,1) 3 DCNUCSC 1)
ALEACHC 1)
SOLUBK( 1)
DCNUCCC 2)
DCNUCU( 2,1)
DCNUCSC 2) 3 ALEACHC 2)
SOLUBK( 2)
DCNUCcC 3)
DCNUCU( 3,1) 3 DCNUCSC 3) 3 ALEACHC 3)
- SOLUBK( 3) 3 DCNUCC( 4)
DCNUCU( 4,1) 3 DCNUCSC 4) 3 ALEACHC 4)
SOLUBK( 4)
INHALR MLINH ED SHF3 SHF1 FiNn used by RESRAD different from user input) 6.309E-05 not used 5.294E-03 not used 1.550E-05 not used 7.224E-04 not used Page 33
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 RO17 Fraction of time spent outdoors (on site) 1.181E-01 I 2.500E-01 3 RO17 3 Shape factor flag, external gamma
' I.OOOE+O0 1
I.OOOE+O0
>0 shows circular AREA.
- IRESRAD, version 6.5 Ts Limit = 30 days 11/26/2011 12:36 Page 6
Summary : HB soil DCGL_Am241 File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\Am24LDCGL\\HB SOIL DCGLAm241.RAD
- FOTD FS Site-Specific Parameter Summary (continued)
SUser Menu Parameter...................
input 3.Def* a u (I....
f..
R017 Radii of shape factor array (used if FS = -1):
3 RO17 Outer annular radius (m),
ring 1:
not used 5.000E+01 R017 Outer annular radius (m),
ring 2:
not used I 7.071E+01 R017 Outer annular radius (m),
ring 3:
not used "O.O00E+O0 R017 Outer annular radius (m),
ring 4:
not used O.OO0E+O0 RO17 Outer annular radius (m),
ring 5:
not used O.00OE+O0 R017 Outer annular radius (m),
ring 6:
not used O.000E+O0 R017 Outer annular radius (m),
ring 7:
not used O.OOOE+OO R017 Outer annular radius (m),
ring 8:
not used O.OOOE+00 ROll Outer annular radius (m),
ring 9:
not used O.000E+OO R017 Outer annular radius (m),
ring 10:
not used O.000E+OO R017 Outer annular radius (m),
ring 11:
not used 0.OOOE+OO R017 Outer annular radius (m),
ring 12:
3 not used O.OOOE+OO ROll Fractions of annular areas within AREA:
3 R017 Ring 1
not used 1.OOOE+OO R017 '
Ring 2
not used 2.732E-01 R017 Ring 3 not used O.OOOE+0O R017 Ring 4
not used O.OOOE+00 R017 Ring 5
not used O.OOOE+00 R017 Ring 6
not used O.OOOE+O0 R017 Ring 7
not used 0.0OOE+O0 R017 Ring 8
not used O.0OOE+O0 ROl7 Ring 9
not used O.OOOE+OO R017 Ring 10 3 not used O.OOOE+00 R017 Ring 11 not used 3O.OOOE-.O0 R017 Ring 12
' not used O.OOOE+-iOI R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 R018 Leafy vegetable consumption (kg/yr) 3 2.140E+01 1.400E+01 R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 RO8 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 3 RO18 Fish consumption (kg/yr) 2.060E+01 5.400E+O0 R018 Other seafood consumption (kg/yr) 9.00OE-01 9.OOOE-01 R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01l ROI8 Drinking water intake (L/yr) 4.785E+02 5.100E+02 R018 Contamination fraction of drinking water 1.000E+00 1.000E+O0 RO18 Contamination fraction of household water not used 1.OOOE+OO R018 Contamination fraction of livestock water 1.O00E+00 1.OOOE+OO R018 Contamination fraction of irrigation water 1.OOOE+00 1.OOE+O0 RO18 Contamination fraction of aquatic food 1.OOOE+OO 5.OOOE-01I R018 Contamination fraction of plant food 1.000E+00
-1l R018 Contamination fraction of meat 1.000E+00 3-1 R018 Contamination fraction of milk 1.00OE+0O
_-1 R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.SOOE+01 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 R019 Livestock water intake for milk (L/day) 6.000E+01
.1600E+02 R019 Livestock soil intake (kg/day) 5.00OE-01
.5000E-01 1RESRAD, version 6.5 TF" Limit = 30 days 11/26/2011 12:36 Page 7
Summary : HR soil DCGLAm241 File
- C:\\RESRADOFAMILY\\RESRAD\\6.5\\USERFILES\\Am241LDCGL\\HB SOIL DCGL_Am241.RAD Site-Specific Parameter Summary (continued) 0 user 3
3 Menu 3Parameter 3
Input
'Default 3(If R019 Mass loading for foliar deposition (g/m*3) 4.000E-04 1.OOOE-04 R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 R019 Depth of roots (m) 1.220E+00 9.O00E-01 R019 Drinking water fraction from ground water 1.000E+00 1.000E+000 R019 Household water fraction from ground water not used 1.OO0E+0O R019 Livestock water fraction from ground water 1.00OE+00 1.OOOE+00 R019 Irrigation fraction from ground water I.OOOE+OO 1.OO0E+0O R19B wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.OOOE-01 R19B Wet weight crop yield for Leafy (kg/m**2))
2.889E+00 1.500E+00 R19B wet weight crop yield for Fodder (kg/m**2) 1.887E+00 I1.100E+00 R198 Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 R19B Growing Season for Leafy (years) 1.230E-Ol 2.500E-01 R19B Growing Season for Fodder (years) 8.200E-02 8.OOOE-02 R19B 3ranslocation Factor for Non-Leafy
" 1.000E-01 1.OOOE-01 R19B Translocation Factor for Leafy
'1.OOE+0O 1.00+/-OE+0 R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 RI9B ' Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 R19B Dry Foliar Interception Fraction for Fodder 3.50OE-01 2.500E-01 R19B Wet Eoliar Interception Fraction for Non-Leafy 3.500E-01 2.50OE-01 R19B Wet Foliar Interception Fraction for Leafy I 5.800E-01 2.500E-01 R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01I R19B weathering Removal Constant for vegetation 3.300E+01 2.OOOE+01 C14 C-12 concentration in water (g/cm**3) not used 2.00OE-05 C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 C14 Fraction of vegetation carbon from soil not used 2.000E-02 c14
' Fraction of vegetation carbon from air not used 9.80OE-01 C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 C14 C-12 evasion flux rate from soil (1/set) not used 1.000E-10 C14 Fraction of grain in beef cattle feed not used 8.000E-01 C14 Fraction of grain in milk cow feed not used 2.000E-01 STOR storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 STOR Leafy vegetables 1.00E+O0 1.000E+00 STOR Milk 1.00OE+O0 1.000E+O0 STOR Meat and poultry 2.000E+01 2.00OE+O1 STOR Fish 7.000E+00 7.OOOE+0O STOR Crustacea and mollusks 7.OOOE+0O 7.000E+00 qTOR 3 well watmr I O0OEr.O IflOr&AO used by RESRAD
.diffe~rent. from.u~ser.i~nput)
AAAA.AAArAAAAAAAAAA Parameter RAD_SHAPE( 1)
RADSHAPE(
2)
RADSHAPE(
3)
RADSHAPE(
4)
RADSHAPE(
5)
RAD.SHAPE(
6) 3RADSHAPE(
7)
RADSHAPE(
8)
RADSHAPE(
9)
RADSHAPE(10)
RADSHAPE(11)
RADSHAPE(12) 3 FRACA( 1)
FRACA( 2)
FRACA( 3) 3 FRACA( 4) 3 FRACA( 5)
FRACA( 6)
FRACA( 7)
FRACA( 8)
FRACA( 9)
FRACA(IO)
FRACA(11)
FRACA(12)
DIET(I)
DIET(2)
DIET(3)
DIET(4)
DIET(5) 3 DIET(6)
SOIL
' DWI FDW FHHW FLW FIRW FR9 PFPLANT FMEAT FMILK LFI5 LFI6 LWI5 SLWlI6 3 LSI Parameter Name MLFD 3DM DROOT FGWDW FGWHH FGWLW FGWIR YV(1)
Yv(2)
Yv(3)
' TE(3) 3 TIV(1)
TIV(2)
TIV(3)
RDRY(1)
RDRY(2)
RDRY(3)
RWET(1)
RWET(2)
RWET(3)
WLAM C12WTR "C12CZ CSOIL CAIR DMC EVSN REVSN AVFG4 AVFG5 3 STOtT(1)
STORLT(2)
STORLT(3)
STORST (4)
STOLT(5)
STOLT(6)
CTflR T(7"1 used by RESRAD different from user input) tBARTLETT Page 34) teA RL ETTPage 34
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 STOR Surface water 1.00OE+00 1.OOOE+00 a
STORT(8)
STOR Livestock fodder 4.500E+01 4.5E1 STORT(9)
R021 Thickness of building foundation (m)
I not used 1.S00E-Ol FLOOR1 R021 Bulk density of building foundation (g/cm**3) 3 not used 2.400E+00 a 3 DENSFL R021 Total porosity of the cover material 3 not used 4.000E-O1 a 3 TPCV R021 a Total porosity of the building foundation 3 not used 3
a TPFL 1RESRAD, version 6.5 Tý, Limit = 30 days 11/26/2011 12:36 Page 8
Summary HB soil DCGL.Am241 File C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\AM241LDCGL\\HB SOIL DCGL.AM241.RAD Site-Specific Parameter Summary (continued) 0 1
User u
ffUsed by RESRAD Parameter Menu Parameter 3
Input Default
- (If different from user input) I Name
-a A...
A.A....Aa e
..u
,.A A.A A A R021 volumetric water content of the cover material not used S.OOOE-02 a PH20CV R021 Volumetric water content of the foundation not used 3.OOOE-02 PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.OOOE-06 DIFCV R021 in foundation material not used 3.OOOE-07 DIFFL R021 in contaminated zone soil not used 2.OOOE-06 a a-DIFCZ R021 Radon vertical dimension of mixing (m) not used a 2.OOOE+O0 HMIX R021 Average building air exchange rate (1/hr) not used
,SOOQE-01 I
REXG R021 Height of the building (room)
(m) not used 2.5OOE+00 HRM R021 Building interior area factor not used 0.OOOE+00 a FAI R021 Building depth below ground surface (m) not used a~I.0OOE+00 3 DMFL R021 Emanating power of Rn-222 gas not used a 2.500E-01 I EMANA(1)
R021 Emanating power of Rn-220 gas not used a 1.5QQE-Ol 3 EMANA(2)
TITL I Number of graphical time points 32 a
NPTS TITL Maximum number of integration points for dose 17 LYMAX TITL 3 Maximum number of integration points for risk 1 i 3
KYMAX Summary of Pathway Selections PathwayUser Selection
...u................
1--
external gamma a
active 2
inhalation (w/o radon)a active 3-- plant ingestion active 4
meat ingestion active 5
milk ingestion active 6
aquatic foods active 7
drinking water active 8 -- soil ingestion active 9 --
radon suppressed Find peak pathway doses active IRESRAD, version 6.5 Tx Limit = 30 days 11/26/2011 12:36 Page 9
Summary : HB soil DCGLAm241 File
- C:\\RESRAOFAMILY\\RESRAD\\6.5\\USERFILES\\A4241LDCGL\\HB SOIL DCGLAM241.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pci/g Area:
30000.00 square meters Am-241 1.OOOE+OO Thickness:
2.67 meters Cover Depth:
0.00 meters IRESRAD, version 6.5 Tx< Limit = 30 days 11/26/2011 12:36 Page 1
Probabilistic results summary : HB soil DCGLAm241 File : C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\AM241LDCGL\\HB SOIL DCGLAM241.RAD Table of Contents Part vI: Uncertainty Analysis ORESRAD Uncertainty Analysis Results Probabilistic Input...
2 Total Dose............................................
4 Total Risk...
5 Dose vs Pathway:
Ground External...................
6 Dose vs Pathway:
Inhalation (w/o Radon) 7 Dose vs Pathway:
Radon (Water Ind.)
8 Dose vs Pathway:
Plant (Water Ind.)................
9 Dose vs Pathway:
Meat (Water Ind.)
10 Dose vs Pathway:
Milk (water Ind.)................
.11 Dose vs Pathway:
Soil Ingestion.....................
12 Dose vs Pathway:
Water Ingestion...................
13 Dose vs Pathway:
Fish Ingestion.....
14 Dose vs Pathway:
Radon (water Dep.).................
15 Dose vs Pathway:
Plant (water Dep.)
16 Dose vs Pathway:
Meat (Water Dep.)
17 Dose vs Pathway:
Milk (water Dep.)
18 cumulative Probability Summary.......................
19 Summary of dose at graphical times, reptition I.....
20 Peak of the mean dose at graphical times.............
21 Correlation and Regression coefficients (if any).....
22
- IRESRAD, version 6.5 T1" Limit = 30 days 11/26/2011 12:36 Page 2
Probabilistic results summanry : HB soil DCGL_Am241 File : C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\Am241LDCGL\\HB SOIL DCGLAM241.RAD probabilistic Input ONumber of Sample Runs: 2000 Number Name Distribution Parameters 1
DENSCZ BOUNDED NORMAL 1.5635
.2385
.827 2.3 2
TPCZ BOUNDED NORMAL
.41
.09
.1319
.6881 3
HCCZ BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 4
BCZ BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 5
EVAPTR UNIFORM
.5
.75 6
RI UNIFORM
.36
.76 7
DENSAQ BOUNDED NORMAL 1.5105
.1855
.937 2.084 8
TPSZ BOUNDED NORMAL
.43
.0699
.214
.646 9
EPSZ BOUNDED NORMAL
.342
.0705
.124
.56 10 HCSZ BOUNDED LOGNORMAL-N.362 1.59
.0106 195 11 BSZ BOUNDED LOGNORMAL-N 1.96
.265 3.02 15.5 t
BARTLETT Page 35
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 12 DWIBWT TRIANGULAR 6
10 30 13 Uw UNIFORM 1173 1973 14 H(1)
UNIFORM 0
8.08 1s DENSUZ(1)
BOUNDED NORMAL 1.5635
.2385
.827 16 TPUZ(1)
BOUNDED NORMAL
.41
.09
.1319 17 EPUZ(1)
BOUNDED NORMAL
.315
.0905
.0349 18 HCUZ(1)
BOUNDED LOGNORMAL-N 1.36 2.17
.00478 19 BUZ(1)
BOUNDED LOGNORMAL-N 1.73
.323 2.08 20 MLINH CONTINUOUS LINEAR 8
0 0
.00003
.8119
.00004
.9495
.00006
.9937
.000076
.9983
.0001 21 SHF3 UNIFORM
.15
.95 22 SHF1 BOUNDED LOGNORMAL-N -1.3
.59
.044 23 DM TRIANGULAR 0
.15
.6 24 Yv(1)
TRUNCATED LOGNORMAL-N.56
.48
.001 25 WLAM TRIANGULAR 5.1 18 84 26 RWET(2)
TRIANGULAR
.06
.67
.95 27 DCACTC(1)
TRUNCATED LOGNORMAL-N 7.28 3.15
.001 28 DCACTU1(1)
TRUNCATED LOGNORMAL-N 7.28 3.15
.001 29 DCACTS(1)
TRUNCATED LOGNORMAL-N 7.28 3.15
.001 30 DCACTC(2)
TRUNCATED LOGNORMAL-N 2.84 2.25
.001 31 DCACTU1(2)
TRUNCATED LOGNORMAL-N 2.84 2.25
.001 32 DCACTS(2)
TRUNCATED LOGNORMAL-N 2.84 2.25
.001 33 DCACTC(3)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001 34 DCACTU1(3)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001 35 DCACTS(3)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001 36 DCACTC(4)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001 37 DCACTU1(4)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001 38 DCACTS(4)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001 39 BRTF(9S,2)
TRUNCATED LOGNORMAL-N -9.9
.2
.001 40 BRTF(9S,3)
TRUNCATED LOGNORMAL-N -13.12
.7
.001 41 BBIO(95,1)
LOGNORMAL-N 3.4 1.1 42 BRTF(93,1)
TRUNCATED LOGNORMAL-N -3.91
.9
.001 43 BRTF(93,2)
TRUNCATED LOGNORMAL-N -6.91
.7
.001 44 BRTF(93,3)
TRUNCATED LOGNORMAL-N -11.51
.7
.001 45 BBIO(93,1)
LOGNORMAL-N 3.4 1.1 46 BRTF(90,1)
TRUNCATED LOGNORMAL-N -6.91
.9
.001 47 BRTF(90,2)
TRUNCATED LOGNORMAL-N -9.21 1
.001 48 BRTF(90,3)
TRUNCATED LOGNORMAL-N -12.21
.9
.001
- 1RESRAD, Version 6.5 T<c Limit -
30 days 11/26/2011 12:36 Page 3
Probabilistic results summary : HB soil DCGLAm241 File : C:\\RESRADFANILY\\RESRAD\\6.5\\USERFILES\\AM241LDCGL\\HB SOIL DCGL.AM241.RAD 2.3
.6881
.594 3190 15.3
.000008 1
1
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.0151
.000016
.1365 Probabilistic Input (cont.)
Number Name Distribution Parameters 49 BBIO(90,1)
LOGNORMAL-N 4.6 1.1 so BRTF(92,1)
TRUNCATED LOGNORMAL-N -6.21
.9
.001
.999 51 BRTF(92,2)
TRUNCATED LOGNORMAL-N
-7.13
.7
.001
.999 52 BRTF(92,3)
TRUNCATED LOGNORMAL-N -7.82
.6
.001
.999 53 BBio(92 1)
LOGNORMAL-N 2.3 1.1 fitlitt liflillittilffittitfif ftftflifillifftlifliti liitifiiilfflififilltlifilifffiffififffi IRESRAD1 Version 6.5 Tm Limit = 30 days 11/26/2011 12:36 Page 21 Probabilistic results summary : HB soil DCGLAm241 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\AM241LDCGL\\HB SOIL DCGL.AM241.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1
0.OOOE+00 9.682E-01 tBARTLETT Page 36
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 C-14 Results:
IRESRAD, Version 6.5 Tc Limit = 30 days 11/26/2011 14:02 Page 1
Summary : HB soil DCGLC14 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\C14_DCGL\\HB SOIL DCGLC14-1.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines f~ifffiftlfliffil IfIffifIfitfltlliffftlllillifffitf~
Dose Conversion Factor (and Related) Parameter Summary...
2 Site-Specific Parameter Summary..........................
3 Summary of Pathway Selections............................
7 Contaminated Zone and Total Dose Summary...................
8 Total Dose Components Time = O.O00E+0O......................................
9 Time = 1.000E+00.....................................
10 Time = 3.0O0E+OO.....................................
11 Time = 1.OOOE+O1......................................
12 Time = 3.OOOE+01.....................................
13 Time = 1.000E+02.....................................
14 Time = 3.OOOE+02......................................
15 Time = 1.OOOE+03..
16 Dose/Source Ratios Summed Over All Pathways...............
17 Single Radionuclide soil Guidelines.......................
17 Dose Per Nuclide Summed Over All Pathways................
18 Soil Concentration Per Nuclide...........................
18 IRESRAD, version 6.5 Tn Limit = 30 days 11/26/2011 14:02 Page 2
Summary : HB soil DCGLC14 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\C14JDCGL\\HB SOIL DCGL_C14-1.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: FGR 12 & FGR 11 0
3 3
Current 3
Base Parameter Menu' Parameter value#
I Case* '
Name A-i DCF's for external ground radiation, (mrem/yr)/(pCi/g)
A-I C-14 (Source:
FGR 12) 1.345E-05 1.345E-05 DCF1(
1)
B-1 Dose conversion factors for inhalation, mrem/pCi:
B-I C-14(p)
(Class: ORGANIC) 2.090E-06 2.090E-06 DCF2(
1)
B-i C-14(g)
(Class: CO2) 2.350E-08 2.350E-08 C14GInhDCF D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 C-14 2.090E-06 2.090E-06 DCF3(
1)
D-34 Food transfer factors:
D-34 C-14
, plant/soil concentration ratio, dimensionless 5.500E+00 5.500E+00 RTF(
1,1)
D-34 C-14 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 3.100E-02 3.100E-02 RTF(
1,2)
D-34 C-14 milk/livestock-intake ratio, (pCi/L)/(pci/d) 1.200E-02 1.200E-02 RTF(
1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 C-14
, fish 5.000E+04 5.OOOE+04 BIOFAC(
1,1)
D-5 C-14 crustacea and mollusks 9.100E+03 I 9.100E+03 3 BIOFAC(
1 2)
- For DCF1(xxx) only, factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Default.Lib w/o Associate Nuclide contributions.
1RESRAD, Version 6.5 T,, Limit = 30 days 11/26/2011 14:02 Page 3
Summary : HB soil DCGL_C14 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\C14_DCGL\\HB SOIL DCGLC14-1.RAD 0
Menu Parameter ROll Area of contaminated zone (m**2)
R011 Thickness of contaminated zone (m)
ROll Fraction of contamination that is submer R011 Length parallel to aquifer flow (m)
R011 Basic radiation dose limit (mrem/yr)
RO11 3 Time since placement of material Cyr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
RO11 Times for calculations (yr)
ROll Times for calculations (yr)
R011 Times for calculations (yr)
R012 Initial principal radionuclide (pCi/g):
R012 Concentration in groundwater (pCi/L):
R013 Cover depth (m)
R013 Density of cover material (g/cm**3)
R013 Cover depth erosion rate (m/yr)
R013 Density of contaminated zone (g/cm**3)
R013 Contaminated zone erosion rate (m/yr)
R013 Contaminated zone total porosity R013 Contaminated zone field capacity R013 Contaminated zone hydraulic conductivity R013 Contaminated zone b parameter R013 Average annual wind speed (m/sec)
R013 Humidity in air (g/m**3)
R013 Evapotranspiration coefficient R013 Precipitation (m/yr)
R013 Irrigation (m/yr)
ROl3 Irrigation mode ROl3 Runoff coefficient R013 watershed area for nearby stream or pond R013 Accuracy for water/soil computations R014 Density of saturated zone (g/cm**3)
R014 Saturated zone total porosity R014 Saturated zone effective porosity R014 Saturated zone field capacity Site-Specific Parameter Summary user 3
3 used by RESRAD Parameter
- 3. input 3, Default 3.(If different from user input)
Name 3.000E+04 1.00E6+04 *---
AREA 2.670E+00 2.000E+00 '
THICKO ged O.OOOE+00 O.000E+00 SUBMFRACT 1.950E+02 1.O00E+02 I LCZPAQ 2.500E+01 3.OO0E+O1 BRDL O.O00E+OO 'O.O0E+O0 TI 1.000E+00 1.O00E+O0 T( 2) 3.O0OE+00 3.000E+00 T( 3) 1.OOOE+01 3 1.OO0E+01 T( 4) 3.000E+01 3.OOOE+0l T( 5) 1.OOOEO+02 1.OOE+2 T( 6) 33.OOOE+02 I.00E+2 T( 7) 1.OOOE+03 '1.000+
T( 8) not used 0.O000E+00 T( 9) not used 0.OO0E+O0 T(10)
C-14 1.OOOE+00 O.000E+00 SI(1)
C-14 not used O.000E+O0 WI( 1)
SO.O00E+0O0 O.OOE+O0 COVERO not used 1.500E+00 DENSCV not used 1.000E-03 I VCv 3 1.564E+00 1.500E+00 DENSCZ 2.200E-03 1.OOOE-03 VCZ 4.100E-01 4.000E-01 TPCZ 9.500E-02 2.000E-01 FCCZ (m/yr) 3.900E+00 1.000E+01 HCCZ 5.600E+00 5.300E+00 BCZ 3.040E+00 2.0OOE+00 WIND not used 8.000E+00 HUMID 6.250E-01 5.O00E-01 EVAPTR 9.100E-01 3 1.000E+00 3 PRECIP 5.600E-01 2.000E-01 RI overhead overhead IITCH 5.O00E-01 2.000E-01 RUNOFF (m**2) 2.520E+07 1.000E+06 3 WAREA 1.OOOE-03 1.006E-03 EPS 1.510E+00 1.500E+00 DENSAQ 4.300E-01 4.000E-01 TPSZ 3.420E-01 2.000E-01 EPSZ 8.800E-02 2.OOOE-01 FCSZ iAA t
BARTLETT Page 37
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R014 I Saturated zone hydraulic conductivity (m/yr) 2.880E+01 1.OOOE+02 HCSZ R014 3 Saturated zone hydraulic gradient 2.OOOE-03 2
2.OOOE-02 HGWT R014 3 Saturated zone b parameter 7.100E+00 3 5.300E+00 BSZ R014 3 Water table drop rate (m/yr)
S 1.OOOE-03 I 1.000E-03
-a-VW-R014 a well pump intake depth (m below water table) 1.0O0E+01 a 1.000E+01 DWIBWT R014 I Model: Nondispersion (ND) or Mass-Balance (MB) 3 NO a NO MODEL R014 3 well pumping rate (m**3/yr) s 1.573E+03 I 2.500E+02 UW IRESRAD, Version 6.5 To Limit = 30 days 11/26/2011 14:02 Page 4
Summary : HB soil DCGL_C14 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\uSERFILES\\C14_DCGL\\HB SOIL DCGLC14-1.RAD Site-Specific Parameter Summary (continued) 0 a
1 User ffUsed by RESRAD Parameter menu Parameter a
Input 3Default a (If different from user input)
Name M ~ ~ ~~u R015 Number of unsaturated zone strata 1
1 3 NS R015 Unsat. zone 1, thickness (m) a 4.040E+00 4.000E+00
~--
H(1)
R015 Unsat. zone 1, soil density (g/cm**3) a 1.564E+00 a 1.500E+00 DENSUZ(1)
R015 Unsat. zone 1, total porosity 4.100E-01 a 4.000E-01 TPUZ(1)
R015 Unsat. zone 1, effective porosity I 3.150E-01 2.000E-01 3 EPUZ(1)
RO15 Unsat. zone 1, field capacity a 9.500E-02 a 2.0OOE-01 a FCUZ(1)
R015 Unsat. zone 1, soil-specific b parameter 5.600E+00 a 5.300E+00 BUZ(1)
R015 Unsat. zone 1, hydraulic conductivity (m/yr) 3.900E+00 1.00OE+01 a HCUZ(1)
R016 Distribution coefficients for C-14 R016 a Contaminated zone (cm**3/g) 1.100E+01 0.000E+00 a DCNUCC( 1)
R016 a unsaturated zone 1 (cm**3/g) a 1.100E+01 a 0.000E+0O a-DCNUCU( 1,1)
RO6I Saturated zone (cm**3/g) a 1.10OE+01 0.000E+00 a-aDCNUCS(
1)
R016 Leach rate (/yr) a 0.000E+00 0.000E+00 a 8.124E-03 a ALEACH( 1)
R016 a Solubility constant O.000E+00 0.000E+00 a not used SOLUBK( 1)
R017 a Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 INHALR R017 Mass loading for inhalation (g/m**3) 1.000E-04 1.000E-04 a-a MLINH R017 a Exposure duration a 3.000E+01 a 3.O0OE+01 ED ROl7 a Shielding factor, inhalation 5.500E-01 a 4.000E-01 SHF3 R017 shielding factor, external gamma 2.725E-01 7.000E-01 a-a SHF1 R017 a Fraction of time spent indoors I 6.571E-01 5.00OE-01 a-FIND R017 a Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 a-a FOTD R017 3 Shape factor flag, external gamma 1.000E+00 1.0O0E+00
>0 shows circular AREA.
FS R017 I Radii of shape factor array (used if FS
-1):
R017 a Outer annular radius (m),
ring 1:
a not used 5.O00E+01 RADSHAPE( 1)
R017 I Outer annular radius (m),
ring 2:
not used a 7.071E+01 a RAD.SHAPE( 2)
R017 a Outer annular radius (m),
ring 3:
not used a 0.0006+00 RAD.SHAPE( 3)
R017 a Outer annular radius (m),
ring 4:
a not used 0.000E+0O RAD.SHAPE(
4)
R017 a Outer annular radius (m),
ring 5:
not used a 0.O00E+00 a RAD.SHAPE( 5)
R017 Outer annular radius (m),
ring 6:
' not used a 0.000E+00 RADSHAPE( 6)
R017 Outer annular radius (m),
ring 7:
a not used a 0.000E+00 RADSHAPE(
7)
R017 Outer annular radius (m),
ring 8:
a not used a 0.O00E+00 RAD.SHAPE( 8)
R017 Outer annular radius (m),
ring 9:
not used 0.000E+OO a RAD.SHAPE( 9)
R017 Outer annular radius (m),
ring 10:
a not used a 0.000E+00 a 3 RAD.SHAPE(10)
R017 Outer annular radius (m),
ring 11:
a not used a 0.O00E+00 3
RAD.SHAPE(11)
R017 Outer annular radius (m),
ring 12:
a not used a 0.000E+00 a RAD.SHAPE(12)
IRESRAD, Version 6.5 T" Limit = 30 days 11/26/2011 14:02 Page 5
Summary : HB soil DCGLC14 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\C14.DCGL\\HB SOIL DCGLC14-1.RAD Site-Specif 0
Menu aParameter R017 Fractions of annular areas within AREA:
R017 Ring 1
ROll Ring 2
R017 Ring 3
R017 Ring 4
R017 a Ring 5
R017 a Ring 6
R017 Ring 7
R017 a Ring 8
R017 3 Ring 9
R017 Ring 10 R017 Ring 11 R017 Ring 12 R018 a Fruits, vegetables and grain consumption (kg/y R018 a Leafy vegetable consumption (kg/yr)
R018 a Milk consumption (L/yr)
R018 a Meat and poultry consumption (kg/yr)
R018 a Fish consumption (kg/yr)
R018 Other seafood consumption (kg/yr)
R018 a Soil ingestion rate (g/yr)
R018 a Drinking water intake (L/yr)
R018 3 Contamination fraction of drinking water RO18 a Contamination fraction of household water R018 a Contamination fraction of livestock water RO18 a Contamination fraction of irrigation water R018 a Contamination fraction of aquatic food R018 Contamination fraction of plant food R018 a Contamination fraction of meat R018 Contamination fraction of milk R019 Livestock fodder intake for meat (kg/day)
R019 Livestock fodder intake for milk (kg/day)
R019 3 Livestock water intake for meat (L/day)
R019 a Livestock water intake for milk (L/day)
R019 Livestock soil intake (kg/day)
R019 a Mass loading for foliar deposition (g/m**3)
R019 Depth of soil mixing layer (m)
R019 a Depth of roots (m)
R019 Drinking water fraction from ground water R019*
Household water fraction from ground water R019 a Livestock water fraction from ground water R019 a Irrigation fraction from groun water R19B Wet weight crop yield for Non-Leafy (kg/m**2)
R19B Wet weight crop yield for Leafy (kg/m**2)
R19B Wet weight crop yield for Fodder (kg/m**2)
R19B Growing Season for Non-Leafy (years)
R19B Growing Season for Leafy (years)
(fB6ARTLETT ic Parameter Summary (continued)
User a
a Input Default
.:(f not used 1.000E+00 not used 2.732E-01 not used
.0000E+0a not used 0.000E+00 not used a 0.OOOE+00 not used 0.OOOE+00 not used 0.000+00a a not used 0.OO0E+OO not used 0.O000E+00
- not used 0.000E+00 not used a O.OOOE+00 a not used O.OOOE+00 r) a 1.120E+02 a 1.600E+02 2.140E+01 1.400E+01 a 2.330E+02 9.200E+01 6.510E+01 6.300E+01 a a 2.060E+01 a 5.400E+00 a 9.00OE-01 a 9.000E-01 a 1.826E+01 a 3.650E+01 a 4.785E+02 a 5.100E+02 1.000E+00 1.00OE+00 not used a 1.OOOE+00 a
- 1.0006E+00 1.000E+00 a 1.000E+00 a 1.000E+00 a 1.0006E+0 5.000E-01 a a I.O006+/-00 '--1 1.0OOE+OO '-1 1.000E+00 :-1 2.710E+01 I 6.800E+01 6.320E+01 a 5.500E+01 5.060E+01 a 5.000E+01 6.000E+01 a 1.600E+02 a 5.000E-01 a 5.000E-01 a 4.000E-04 I 1.000E-04 a 2.300E-01 a 1.500E-01 a 1.220E+00 9.000E-01 1.000E+00 a 1.000E+00 a not used a 1.000E+00 a 1.O00E+00 a 1.O00E+O0
- 1.000E+00 1.0006E+0 1.750E+00 7.000E-01 2.889E+00 1.500E+00 a 1.887E+00 1.100E+00 2.460E-01 a 1.700E-01 a a 1.230E-1 3 2.S00E-01 a
used by RESRAD different from user input) aX XX ra..
SXAA
_A.AAAAA Parameter S Name FRACA(
1) a FRACA(
2)
FRACA(
3)
FRACA(
4)
FRACA(
5)
FRACA(
6)
FRACA(
7)
FRACA(
8)
FRACA(
9)
FRACA(10)
FRACA(11)
FRACA(12)
DIET(1)
DIET(2)
DIET(3)
DIET(4)
DIET(S)
DIET(6) a SOIL DWl FDW FHHW a FLW a FIRW a FR9 FPLANT FMEAT FMILK LFI5 a LFI6 a LWIS a LWI6 a LSI a MLFD a DM 3 DROOT a FGWDW I FGWHH I FGWLW a FGWIR a YV(1) a Yv(2) 3YV(3) a TE(1) 3 TF 0)
Page 38
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 R19B C
Growing Season for Fodder (years) 8.200E-02 I 8.OOOE-02 TE(3) 1RESRAD, Version 6.5 T< Limit = 30 days 11/26/2011 14:02 Page 6
Summary : HB soil DCGL_C14 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\C14_DCGL\\HB SOIL DCGLC14-1.RAD Site-Specific Parameter Summary (continued) 0 3
User S
a used by RESRAD 3
Parameter Menu 3 Parameter Inpu...'...aDefault (if different from user inpqut)
Name R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 TIV(1)
R19e Translocation Factor for Leafy 1.O00E+00 1.000E+00 a-a TIv(2)
RI9B Translocation Factor for Fodder 1.OooE+O0 I.000E+00 TIV(3)
Ri9e Dry Foliar Interception Fraction for Non-Leafy a 3.SOOE-01 a 2.500E-01 RDRY(1)
R19i a Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 RDRY(2)
R19i Dry Foliar Interception Fraction for Fodder a 3.50OE-01 a 2.500E-01 a 3 RDRY(3)
RI9B wet Foliar Interception Fraction for Non-Leafy a 3.SOOE-01 2.500E-01 RWET(1)
RI9B wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 RWET(2)
R19B wet Foliar Interception Fraction for Fodder 3.500E-01 a 2.500E-01 a-- RWET(3)
R19B a weathering Removal Constant for vegetation a 3.300E+01 3 2.OOOE+01 a WLAM C14 C-12 concentration in water (g/cm**3) a 2.OOOE-05 2.OOOE-05 a-a C12WTR C14 C-12 concentration in contaminated soil (g/g) 3.000E-02 3.OOOE-02 c12CZ C14 Fraction of vegetation carbon from soil 2.000E-02 2.000E-02 a-a CSOIL C14 a Fraction of vegetation carbon from air a 9.800E-01 a 9.800E-01 CAIR C14 a C-14 evasion layer thickness in soil (m) a 4.270E-01 a 3.OOOE-01 DMC C14 a C-14 evasion flux rate from soil (1/sec) a 7.000E-07 7.OOOE-07 EVSN C14 a C-12 evasion flux rate from soil (1/sec) a 1.0006-10 1,00E-_10 a-REVSN C14 a Fraction of grain in beef cattle feed a 2.SooE-01 a 8.OOOE-01 a-AVFG4 C14 a Fraction of grain in milk cow feed a 1.000E-01 a 2.OQOE-01 a-a AVFGS STOR a Storage times of contaminated foodstuffs (days):
a a
STOR a Fruits, non-leafy vegetables, and grain a 1.400E+01 a 1.400E+01 a-a STORT(1)
STOR a Leafy vegetables a 1.00OE+00 1.OOOE+00 a-a STORT(2)
STOR Milk 1.000E+00 1.OOOE+00
-STOa T(3)
STOR Meat and poultry 2.000E+01 a 2.000E+01 STORT(4)
STOR a Fish a 7.000E+00 a 7.OOOE+00 aSTORT(5)
STOR a Crustacea and mollusks 7.000E+00 a 7.OOOE+00 a-STORST(6)
STOR a Well water a 1.OOOE+00 1.OOOE+00 a-a STOLT(7)
STOR Surface water 1.000I+00 1.OOOE+00 a SEORL-T(8)
STOR a Livestock fodder a 4.500E+01 a 4.500E+01 a-STOET(9)
R021 Thickness of buildino foundation (m) a not used a 1.500E-01 FLOOR1 R021 Bulk density of buil aing foundation (g/cm**3) not used a 2.400E+00 DENSFL R021 Total porosity of the cover material not used a 4.000E-01 a TPCV R021 Total porosity of the building foundation not used a 1.000E-01 TPFL R021 volumetric water content of the cover material not used a 5.000E-02 PH2OCV R021 volumetric water content of the foundation not used a 3.000E-02 a PH2OFL R021 Diffusion coefficient for radon gas (m/set):
a R021 a in cover material not used a 2.000E-06 a DIFCV R021 a in foundation material not used 3.000E-07 a DIFFL R021 a in contaminated zone soil not used a 2.000E-06 a DIFCZ R021 a Radon vertical dimension of mixing (m) not used a 2.000E+00 aHMIX R021 a Average building air exchange rate (1/hr) not used a S.000E-01 REXG R021 a Height of the building (room)
(m) not used 2.500E+00 a-HRM R021 Building interior area factor not used 0.000E+00 FAI R021 Building depth below ground surface (mi) not used 3-1.0 0 0E+00 a DMFL R021 a Emanating power of Rn-222 gas not used a 2.500E-01 aEMANA(1)
R021 Emanating power of Rn-220 gas not used a 1.500E-01 EMANA(2)
TITL a Number of graphical time points 32 a
NPTS IRESRAD, Version 6.5 T-Limit = 30 days 11/26/2011 14:02 Page 7
Summary : HB soil DCGL_C14 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\C1l4DCGL\\HB SOIL DCGLC14-1.RAD Site-Specific Parameter Summary (continued) 0 3
user a
used by RESRAD Parameter Menu a.
Parameter a..
Input
.Default (I*.
f different from user input)
Name TITL Maximum number of integration points for dose 17 a
a a LYMAX TITL a Maximum number of integration points for risk k
1 aa KYMAX Summary of Pathway selections
.Pathway a
user Selection X...........
- l.
1-- external gamma 3
active 2
inhalation (w/o radon)'
active 3-- plant ingestion active 4
meat ingestion active 5
milk ingestion active 6-- aquatic foods active 7
drinking water active 8
soil ingestion active 9 --
radon suppressed Find peak pathway doses active
- 1RESRAD, Version 6.5 T.' Limit = 30 days 11/26/2011 14:02 Page 8
Summary : HB soil DCGLC14 File
- C:\\RESRADSFAMILY\\RESRAD\\6.5\\USERFILES\\C14_DCGL\\HB SOIL DCGLC14-1.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area:
30000.00 square meters C-14 1.000E+00 Thickness:
2.67 meters Cover Depth:
0.00 meters IRESRAD, Version 6.5 Tv Limit = 30 days 11/26/2011 14:02 Page 1
Probabilistic results summary : HB soil DCGL_C14 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\C14_DCGL\\HB SOIL DCGLC14-1.RAD Table of Contents Part VI: Uncertainty Analysis ORESRAD Uncertainty Analysis Results Probabilistic Input..
2 Total Dose..
3 Total Risk..
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Dose vs Pathway:
Ground External...................
5 Dose vs Pathway:
Inhalation (w/o Radon)............
6 Dose vs Pathway:
Radon (Water Ind.)................
7 Dose vs Pathway:
Plant (water Ind.)................
8 Dose vs Pathway:
Meat (water Ind.)................
9 Dose vs Pathway:
Milk (water Ind.)................
10 Dose vs Pathway:
Soil Ingestion...................
11 Dose vs Pathway:
Water Ingestion...................
12 Dose VS Pathway:
Fish Ingestion....................
13 Dose vs Pathway:
Radon (Water Dep.).................
14 Dose VS Pathway:
Plant (Water Dep.).................
15 Dose vs Pathway:
Meat (Water Dep.)
16 Dose vs Pathway:
Milk (Water Dep.)
17 cumulative Probability Summary.......................
18 summary of dose at graphical times, reptition 1.....
19 Peak of the mean dose at graphical times.............
20 correlation and Regression coefficients (if any).....
21
- 1RESRAD, version 6.5 Ta Limit = 30 days
.11/26/2011 14:02 Page 2
Probabilistic results summary : HB soil DCGLC14 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\C14_DCGL\\HB SOIL DCGLSC14-1.RAD Probabilistic Input ONumber of Sample Runs: 2000 Number 1
2 3
45 6
7 8
9 10 11 12 13 14 15 16 17 18 19 20
.00003 21 22 23 24 25 26 27 28 29 30 31 32 33 ftttt3 Name Distribution DENSCZ BOUNDED NORMAL DPCZ BOUNDED NORMAL HCCZ BOUNDED LOGNORMAL-N BCZ BOUNDED LOGNORPAL-N EVAPTR UNIFORM RI UNIFORM DENSAQ BOUNDED NORMAL TPSZ BOUNDED NORMAL EPSZ BOUNDED NORMAL ECSZ BOUNDED LOGNORMAL-N BSZ BOUNDED LOGNORMAL-N DWlBWT TRIANGULAR UW UNIFORM H(1)
UNIFORM DENSUZ(1)
BOUNDED NORMAL TPUZ(1)
BOUNDED NORMAL EPUZ(1)
BOUNDED NORMAL HCUZ(1)
BOUNDED LOGNORMAL-N BUZ(1)
BOUNDED LOGNORMAL-N MLINR CONTINUOUS LINEAR
.8119
.00004
.9495
.00006
.9937 SHF3 UNIFORM SHF1 BOUNDED LOGNORMAL-N DM TRIANGULAR Yv(1)
TRUNCATED LOGNORMAL-N WLAM TRIANGULAR RWET(2)
TRIANGULAR DCACTC(1)
TRUNCATED LOGNORMAL-N DCACTUC(1)
TRUNCATED LOGNORMAL-N DCACTS(1)
TRUNCATED LOGNORMAL-N BRTF(6,1)
TRUNCATED LOGNORMAL-N BRTF(6,2)
TRUNCATED LOGNORMAL-N BRTF(6,3)
TRUNCATED LOGNORMAL-N BBIO(6 1)
LOGNORMAL-N tftiftt ilititttitffft ttffftt fttttttttttMt Parameters 1.5635
.2385
.827 2.3
.41
.09
.1319
.6881 1.36 2.17
.00478 3190 1.73
.323 2.08 15.3
.5
.75
.36
.76 1.5105
.1855
.937 2.084
.43
.0699
.214
.646
.342
.0705
.124
.56
.362 1.59
.0106 195 1.96
.265 3.02 15.5 6
10 30 1173 1973 0
8.08 1.5635
.2385
.827 2.3
.41
.09
.1319
.6881
.315
.0905
.0349
.594 1.36 2.17
.00478 3190 1.73
.323 2.08 15.3 8
0 0
.000008
.0151
.000016
.1365
.000076
.9983
.0001 1
.15
.95
-1.3
.59
.044 1
0
.15
.6
.56
.48
.001
.999 5.1 18 84
.06
.67
.95 2.4 3.22
.001
.999 2.4 3.22
.001
.999 2.4 3.22
.001
.999
-. 36
.9
.001
.999
-4.47 1
.001
.999
-4.4
.9
.001
.999 10.8 1.1 ftttItttIt ttt+/-+/-t+/-
t1+/-tittit+/-3ftttf t
IRESRAD, Version 6.5 T-Limit = 30 days 11/26/2011 14:02 Page 20 Probabilistic results summary : HB soil DCGLCI4 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\C14_DCGL\\HB SOIL DCGLC14-1.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1
O.OOOE+00 3.968E+00 t
BARTLETT Page 40
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 Cm-243 Results:
1RESRAD, version 6.5 T-Limit = 30 days 11/28/2011 09:51 Page 1
Summary HB soil DCGL_Cm243 File C:\\RESRA0DFAMILY\\RESRAD\\6.5\\USERFILES\\CM243 DCGL\\HR SOIL DCGOL.CM243.RAD Table of Contents Part 1: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary...
2 Site-Specific Parameter Summary..........................
4 Summary of Pathway Selections..............................
8 Contaminated Zone and Total Dose Summary.................
9 Total Dose Components Time = 0.O0E+O0......................................
10 Time = 1.000E+00.....................................
11 Time= 3.OOOE+/-0O....................................... 12 Time = 1.000E+01....................................
13 Time = 3. O E+O1....................................
14 Time = 1.OOOE+02......................................
15 Time 3.OOOE+02....................................
16 Time = 1.000E+03 17 Dose/source Ratios Summed over All Pathways..................
18 single Radionuclide Soil Guidelines.........................
18 Dose Per Nuclide Summed over All Pathways 19 Soil Concentration Per Nuclide...........................
20
- iRESRAD,
'Version 6.5 Tu Limit = 30 days..
/28/2011 09:51 Page 2
Summary :rB soil DCOLs1m243 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\CM243 DCGL\\HB SOIL DCGL_CM243.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: HB DCGLS Plus FGR 12 & FGR 11 O
33Crrent 3
Base 3Parameter menu 3 Parameter value#
a Case*m Nam A-1 DCF's for external ground radiation, (mrem/yr)/(pCi/g)
A-1I AC-227 (Source: FGR 12) 4.951E-04 4.951E-04 DCF1(
1)
A-i Am-243 (Source: FOR 12) 31.420E-O1 a1.420E-01 DCP1(
2)
A-1 Bi-211 (Source: FGR 12) 12559E-01 2.559E-01 DCF1(
3)
A-1 Cm-243 (Source:
FGR 12) 5.829E-01 5.829E-01 IDCF(
4)
A-1 Fr-223 (Source:
FGR 12) 1.980E-01 1.980E-01 DCF1(
5)
A-1 Np-239 (Source:
FGR 12) 7.529E-01 7.529E-01 DCFi(
6)
A-1 Pa-231 (Source:
FGR 12) 1.906E-0i 1.906E-01 DCF1(
7)
A-1 Pb-211 (Source: FGR 12) 3.064E-01 3.064E-01 DCF1(
8)
A-I Po-211 (Source: FGR 12) 4.764E-02 4.764E-02 DCF1(
9)
A-1 Po-215 (Source:
FGR 12) 1.016E-03 1.016E-03 DCFI( 10)
A-1 Pu-239 (Source: FGR 12) 2.952E-04 2.952E-04 a DCFi( 11)
A-1 Ra-223 (Source:
FGR 12) 6.034E-01 6.034E-01 DCF1( 12)
A-1 Rn-219 (Source: FGR 12) 3.083E-01 3.083E-01 DCFi( 13)
A-i Th-227 (Source: FGR 12)
S.212E-01 5.212E-01 DCF1( 14)
A-i Th-231 (Source:
FGR 12) 3.643E-02 3.643E-02 DCFI(
15)
A-I Tl-207 (Source: FGR 12) 1.980E-02 I i.980E-02 DCF1( 16)
A-1 u-235 (Source:
FGR 12) 7.211E-01 7.211E-01 DCFi( 17)
B-i Dose conversion factors for inhalation, mrem/pCi:
B-i AC-227+D 6.724E+00 6.700E+00 DCF2(
1)
B-i Am-243+D 4.400E-01 '4.400E-0i DCF2( 2)
B-1 Cm-243 3.070E-01 3.070E-01 DCF2(
3)
B-1 Pa-231 1.280E+00 1.280E+00 DCF2(
5)
B-I Pu-239 4.290E-01 4.290E-00 DCF2(
6)
B-1 u-235+D 1.230E-01 1.230E-01 DCF2(
7)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 AC-227+D 1.480E-02 I1.410E-02 DCF3(
1)
D-1 I Am-243+D 33.623E-03 I3.620E-03 'DCF3(
2)
D-1 Cm-243 32.510E-03 2.510E-03 DCF3(
3)
D-1 Pa-231 1.060E-02 1.060E-02 DCF3(
5)
D-1 Pu-239 3 3.540E-03 13.540-03 DCF3(
6)
D-1 u-235+D 2.673E-04 I 2.660E-04 DCF3(
7)
D-34 Food transfer factors:
3 D-34 3 AC-227+D
, plant/soil concentration ratio, dimensionless 2.500E-03 2.500E-03 RTF(
1,1)
D-34 3Ac-227+D ee f/livestock-intake ratio, (pci/kg)/(pCi/d) 32.0OE0DB-O 2.00E05-OS RTF(
1,2)
D-34 AC-227+D milk/livestock-intake ratio, (pCi/L) /(pci/d) 2.OOOE-05 2.000E-OS RTF(
1,3)
D-34 3 D-34 Am-243+D
,lant/soil concentration ratio, dimensionless 1.830E-03 1.0005-03 3 RTF(
2.1)
D-34 Am-243+D eef/laivestock-intake ratio, (pCi/kg)/(pCi/d)
.OOOE-0S 1.000E-03 RTF(
2,2)
D-34 Am-243+D milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.OOOE-06 2.000E-06 RTF(
2,3)
D-34 3
3 3
D-34 Cm-243
,lant/soil concentration ratio, dimensionless i.830E-03 1.0005-03 RTF(
3,1)
D-34 Cm-243 eef/laivestock-intake ratio, (pci/k)/(pci/d) 2.OOOE-0S 2.O00E-05 RTF(
3,2)
D-34 Cm-243 milk/livestock-intake ratio, (pCi/kg/(pci/d) 2.OOOE-06 2.OOOE-06 RTF(
3,3)
D-343 IRESRAD, Version 6.5 T-Limit = 30 days 11/28/2011 09:51 Page 3
Summary
- HB soil DCGL-Cm243 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM243 DCGL\\HB SOIL DCGLCM243.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)
Dose Library: HB DCGLs Plus FGR 12 & FGR 11 0
current
- Base Parameter menu 'sParameter value#
Case Nam D-34 Pa-231
, plant/soil concentration ratio, dimensionless 1.000E-02 1.000E-02 RTF(
5,1)
D-34 3 Pa-231 beef/livestock-intake ratio, (pCi/kg)/(pCi/d)
S.O00E-03 5.OOO-03 RTF(
5,2)
D-34 Pa-231 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 5.OOOE-06 5.OOOE-06 RTF(
5,3)
D-343 D-34 Pu-239
, plant/soil concentration ratio, dimensionless 1.830E-03 1.OOOE-03 RTF(
6,1)
D-34 Pu-239 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-04 1.000E-04 RTF(
6,2)
D-34 Pu-239 milk/livestock-intake ratio, (pCi/L /(pCi/d) 1.OOOE-06 1.000E-06 RTF(
6,3)
D-34 3 D-34 3 U-235+0
, plant/soil concentration ratio, dimensionless 2.500E-03 2.500E-03 RTF(
7,1)
D-34 3 u-235+D beef/livestock-intake ratio, (pCi/kg)/(pci/d) 3.400E-04 3.400E-04 RTF(
7,2)
D-34 U-235+D milk/livestock-intake ratio, (pci/L) /(pCi/d) 6.000E-04 6.000E-04 RTF(
7,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Ac-227+D
, fish 1.500E+01 1.500E+01 BIOFAC(
1,1) t DART L Ef Page 41
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 D-5 AC-227+D crustacea and mollusks 1.O00E+03 1.000E+03 BIOFAC(
1,2)
D-5 D-5 Am-243+D fish 3.000E+01 3.000E+O1 BIOFAC(
2,1)
D-5 Am-243+D crustacea and mollusks 1.O00E+03 1.OOOE+03 BIOFAC(
2,2)
D-5 D-5 Cm-243 fish 3.0OOE+O1 3.OOOE+01 BIOFAC(
3,1)
D-5 Cm-243 crustacea and mollusks 1.OOOE+03 l.OOOE+03 BIOFAC(
3,2)
D-5I D-5 Pa-231
, fish 1.OOOE+01 1.OOOE+01 BIOFAC(
5,1)
D-5 Pa-231
, crustacea and mol.lusks 1.100E+02 1.100E+02 BIOFAC(
5,2)
D-5 D-5 Pu-239
, fish 3.000E+01 3.OOOE+01 BIOFAC(
6,1)
D-5 Pu-239
, crustacea and mollusks 1.000E+02 1.OOOE+02 BIOFAC(
6,2)
D-53 D-5 u-235+D
, fish 1.000E+Ol 1.000E+Oi BIOFAC(
7,1)
D-5 u-235+Dc
.crustacea and mollusks 6.00OE+03 6.000tE+Oi 3BIOFAC(
7 2)
- For DCFl(xxx) only, factors are for infinite depth & area.
See ETFG table. in Ground Pathway of Detailed Report.
- Base Case means Default.Lib w/o Associate Nuclide contributions.
- IRESRAD, Version 6.5 T. Limit = 30 days 11/28/2011 09:51 Page 4
Summary :-HB soil DCGLCm243 File C:\\RESRAD-FAMILY\\RESRAD\\6.5\\USERFILES\\CM243 DCGL\\HB SOIL DCGLCM243.RAD 0
Menu
.Para eter R011 Area of contaminated zone (m**2)
ROll Thickness of contaminated zone (m)
R011 Fraction of contamination that is submer R011 Length parallel to aquifer flow (m)
R011 Basic radiation dose limit (mrem/yr)
R011 Time since placement of material (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
RO11 Times for calculations (yr)
R011 Times for calculations (yr)
ROll Times for calculations (yr)
ROll Times for calculations (yr)
ROll Times for calculations (yr)
R011 Times for calculations (yr)
R012 Initial principal radionuclide (pCi/g):
R012 Concentration in groundwater (pCi/L):
R013 Cover depth (m)
R013 Density of cover material (g/cm**3)
R013 Cover depth erosion rate (m/yr)
R013 Density of contaminated zone (g/cm**3)
R013 Contaminated zone erosion rate (m/yr)
R013 Contaminated zone total porosity R013 Contaminated zone field capacity R013 I Contaminated zone hydraulic conductivity R013 Contaminated zone b parameter R013 Average annual wind speed (m/sec)
R013 Humidity in air (g/m**3)
R013 Evapotranspiration coefficient R013 Precipitation (m/yr)
R013 Irrigation (m/yr)
R013 Irrigation mode R013 Runoff coefficient ROl3 watershed area for nearby stream or pond R013 Accuracy for water/soil computations R014 Density of saturated zone (g/cm**3)
RO14 Saturated zone total porosity R014 Saturated zone effective porosity R014 Saturated zone field capacity R014 Saturated zone hydraulic conductivity (m R014 Saturated zone hydraulic gradient R014 Saturated zone b parameter R014 water table drop rate (m/yr)
R014 well pump intake depth (m below water ta R014 Model: Nondispersion (ND) or Mass-Balanc R014 well pumping rate (m**3/yr)
Site-Specific Parameter Summary User 3
Used by RESRAD Parameter
". Input 3.Default 3( If different from user input)
Name "3.0OE+04 1.OOOE+04 AREA 2.670E+00 2.OOOE+oO THICKO ged O.000E+00 O.OOOE+00 SUBMFRACT 1.950E+02 I 1.000E+02 LCZPAQ 2.500E+01 3.OOOE+01 BRDL O.000E+OO O.OOOE+/-O0 TI I.OOE+OO 3.OOOE+OO T( 2) 3.00OE+O0 3.OOOE+O0 T( 3) 1.000E+01 1.OOOE+01 T( 4) 3.OOOE+01 3.000E+O1 T( 5) 3.000E+02 1.OOOE+02 T( 6) 3.000E+02 3.OO0E+02 T(
7) 1.000E+03
.OOOE+03 T( 8) not used O.OOOE+00 T( 9) not used O.OO0E+OO T(IO)
Cm-243 1.OOOE+O0 O.000E+OO S1(3)
Cm-243 not used O.OOOE+OO wl( 3)
O.OOOE+OO O.OOOE+O0 COVERO not used 1.500E+O0 3 DENSCV not used 1.OOOE-03 VCV 1.564E+00 1.500E+O0 DENSCZ 2.200E-03 1.OOOE-03 VCZ 4.100E-01 4.OOOE-01 TPCZ 9.500E-02 2.OOOE-01 FCCZ (m/yr) 3.900E+00 1.000E+01 HCCZ 5.600E+00 5.300E+00 BCZ 3.040E+00 2.000E+O0 WIND not used 8.000E+00 HUMID 6.250E-01 5.000E_-O EVAPTR 9.100E-01 1.000E+00 PRECIP 5.600E-01 2.OOOE-01 RI overhead overhead IDITCH 5.000E-01 2.OOOE-0 RUNOFF (m**2) 2.520E+07 1.OOOE+06 WAREA 1.O00E-03 1.OOOE-03 EPS 1.510E+00 1.500E+00 DENSAQ 4.300E-01 4.000E-01 TPSZ 3.420E-01 3 2.000E-01 EPSZ 8.800E-02 2.000E-01 FCSZ
/yr) 2.880E+01 1.000E+02 HCSZ 2.000E-03 2.000E-02 HGw-r 7.1OOE+00 5.300E+00 3--
BSZ 1.00OE-03 I1.O00E-03 WT ble)
I1.00E+01 1.000E+01 DWIBWT e (MB) 3 NO ND 3 MODEL 1.573E+03 2.500E+02 UW IRESRAD, Version 6.5 T. Limit = 30 days 11/28/2011 09:51 Page 5
Summary : HB soil DCGLCm243 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM243 DCGL\\HB SOIL DCGLCM243.RAD 0
3 Menu P.aramet...........
R015 ' Number of unsaturated zone strata R015 3 Unsat. zone 1, thickness (m)
R015 ' Unsat. zone 1, soil density (g/cm**
R015 3 Unsat. zone 1, total porosity ROS I Unsat. zone 1, effective porosity RO15 I Unsat. zone 1, field capacity R015 3 Unsat. zone 1, soil-specific b par R015 Unsat. zone 1, hydraulic conductivi R016 Distribution coefficients for Cm-2 R016 Contaminated zone (cm**3/g)
R016 Unsaturated zone I (cm*3/g)
R016 Saturated zone (cm**3/g)
R016 Leach rate (/yr)
R016 Solubility constant R016 3 Distribution coefficients for daugi R016 Contaminated zone (cm**3/g)
R016 Unsaturated zone 1 (cm**3/g)
R016 Saturated zone (cm**3/g)
R016 Leach rate (/yr)
R016 Solubility constant R016 Distribution coefficients for daugi R016 Contaminated zone (cm**3/g)
R016 Unsaturated zone 1 (cm**3/g)
(eBARTLETT Site-Specific Parameter Summary (continued)
User used by RESRAD Parameter Input e
Default 3.(If different from user input) 3 Name i 1 NS I 4.040E+00 I 4.000E+O0 H(I)
'3) 1.564E+00 1.500E+00 DENSUZ(1) 4.1OOE-01 4.000E-01 TPUZ(1) 3.150E-01 2.OOOE-Ol EPUZ(1) 9.5OOE-02 2.OOOE-01 FCUZ(1) ameter 5.600E+00 5.300E+00 BUZ(1) ity (m/yr) 3.900E+00 1.000E+O1 HCUZ(1) 43 3
3 6.761E+03 '-1.O00E+00 3
DCNUCC( 3) 6.761E+03 '-I.OOOE+0O DCNUCU( 3,:
6.761E+03 '-1.0006+00 DCNUCS(
3)
O.O00E+O0 0.006E+00 1.349E-05 ALEACH( 3) 3OO00E+00 O.O006E+00 not used SOLUBK(
3) hter AC-227 8.250E+02 2.000E+01 DCNUCC( 1) 8.250E+02 3 2.000E+01 DCNUCU( 1,:
8.250E+02 3 2.OOOE+01 DCNUCS( 1)
O.OOOE+00 O.OOOE+O0 1.105E-04 ALEACH( 1) 3O.00E+00 O.OOOE+00 not used SOLUBK( 1) hter Am-243 1.445E+03 2.OOOE+01 DCNUCC( 2) 1.445E+03 2.000F+01 DCNUCU( 2.
5AA 1) i)
Page 42
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R016 Saturated zone (cm**3/g) 1.445E+03 2.000E+01 DCNUCS( 2)
R016 Leach rate (/yr)
O.OOOE+O0 O.OOOE+00 6.309E-05 ALEACH( 2)
R016 Solubility constant O.00E+O0 O.OOOE+00 not used SOLUBK( 2)
R016 Distribution coefficients for daughter Pa-231 R016 Contaminated zone (cm**3/g) 3.860E+02 5.OOOE+O1 DCNUCC( 5)
R016 Unsaturated zone 1 (cm**3/g) 3.800E+02 5.OOOE+01 DCNUCU( 5,1)
R016 Saturated zone (cm**3/g) 3.800E+02 5.000E+01 DCNUCS( 5)
R016 Leach rate (/yr)
O.OOOE+00 0.000E+00 2.398E-04 ALEACH( 5)
R016 Solubility constant O.OOOE+00 O.OOOE+00 not used SOLUBK( 5)
R016 Distribution coefficients for daughter Pu-239 R016 Contaminated zone (cm**3/g) 9.530E+02 2.000E+03 DCNUCC( 6)
R016 Unsaturated zone 1 (cm**3/g) 9.530E+02 2.000E+03 3 DCNUCU( 6.1)
RO16 Saturated zone (cm**3/g) 9.530E+02 2.OOOE+03 '-DCNUCS(
6)
R016 Leach rate (/yr)
O.OOOE+0O0 0.000E+00 9.565E-05 ALEACH( 6)
R016 Solubility constant O.O00E+0O O.O00E+00 not used SOLUBK( 6)
RO16 Distribution coefficients for daughter u-235 R016 Contaminated zone (cm**3/g) 1.260E+02 5.000E+O1 DCNUCC( 7)
R016 Unsaturated zone 1 (cm**3/g) 1.260E+02 S.OOOE+01 3 DCNUCU( 7,1)
R016 Saturated zone (cm**3/g) 1.260E+02 5.OOOE+01 DCNUCS( 7)
R016 Leach rate (/yr)
O.O0E+O0 OO00E+00 7.224E-04 ALEACH( 7)
R016 Solubility constant O.O00E+O0 O.O00E+00 not used SOLURK( 7)
IRESRAD, Version 6.5 Tv Limit = 30 days 11/28/2011 09:51 Page 6
Summary HB soil DCGLCm243 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM243 DCGL\\HB SOIL DCGLSCM243.RAD Site-Specific Parameter Summary (continued) 0 3
3 User 3
used by RESRAD 3 Parameter Menu P arame**er I nput 3 Default 3.(if different from user input)
Name R017 inhalation rate (m**3/yr) 8.400E+03 8.400E+03 INHALR R017 Mass loading for inhalation (g/m**3) 1.000E-04 1.000E-04 MLINH R017 Exposure duration 3.OOOE+01 3.000E+01 ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 SHF3 R017 Shielding factor, external gamma 3.980E-01 7.000E-01 3 SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 3 FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+0O
>0 shows circular AREA.
FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m),
ring 1
not used 5.000E+01 RADSHAPE(
1)
R017 Outer annular radius (m),
ring 2:
not used 7.071E+01 3 RADSHAPE(
2)
R017 Outer annular radius (m),
ring 3
not used O.OOOE+00 RADSHAPE(
3)
R017 Outer annular radius (m),
ring 4:
not used 0.000E+00 RADSHAPE( 4)
R017 Outer annular radius (m),
ring 5
not used 0.000E+00 RADSHAPE(
5)
R017 Outer annular radius (m),
ring 6:
not used O.000E+00 RADSHAPE( 6)
R017 Outer annular radius (m),
ring 7
not used 0.00OE+00 1---
RADSHAPE(
7)
R017 Outer annular radius (m),
ring 8:
not used 0.000E+00 RADSHAPE(
8)
R017 Outer annular radius (m),
ring 9:
not used 0.000E+00 RADSHAPE(
9)
R017 Outer annular radius (m),
ring 10:
not used 3 O.OOOE+00 RADSHAPE(1O)
R017 outer annular radius (m),
ring 11:
not used O.OOOE+00 RADSHAPE(11)
R017 Outer annular radius (m),
ring 12:
not used O.OOOE+00 RADSHAPE(12)
R017 Fractions of annular areas within AREA:
3 R017 Ring 1
not used 1.000E+00 FRACA( 1)
R017 Ring 2
not used 2.732E-01 PRACA( 2)
R017 Ring 3
not used 0.00E+00 FRACA( 3)
R017 Ring 4
not used 0.000E+00 FRACA( 4)
R017 Ring 5
not used O.000E+00 FwACA( 5)
R017 Ring 6
not used 0.000E+00 FRACA( 6)
R017 Ring 7
not used 0.000E+00 FRACA( 7)
R017 Ring 8
not used O.000E+00
'-FRACA(
8)
R017 Ring 9
not used 0,000E+00 FRACA( 9)
R017 Ring 10 not used O.000E+00 FRACA(10)
R017 Ring 11 not used 0.000E+00--
FRACA(11)
R017 3 Ring 12 not used 0.000E+00 FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 DIET(l)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 3--
DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 DIET(S)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.00aE-01 DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 DWI R018 Contamination fraction of drinking water 31.00E+00 31,00E+00 FDW R018 Contamination fraction of household water not used 31.0aE+00 FHHW R018 Contamination fraction of livestock water 1.0E+00 I 1.000E+00 FLW R018 Contamination fraction of irrigation water 31.00E+00 1.000E+00 FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 FR9 R018 Contamination fraction of plant food 31.0aE+00
-1 FPLANT IRESwAD, Version 6.5 T. Limit = 30 days 11/28/2011 09:51 Page 7
Summary
- HB soil DCGLCm243 File
- C:\\RESRAD.FAMILY\\RESRAD\\6.5\\USERFILES\\CM243 DCGL\\HB SOIL DCGLCM243.RAD Site-Specific Parameter Summary (continued) 0 User used by RESRAD Parameter Menu 3 Parameter........................................
I np.u.
p.
.... Default (If different from user input) '
Name R018 Contamination fraction of meat 1.000E+00 3-1 FMEAT R018w Contamination fraction of milk 1.0a0E+00 FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 3 6.800E+01 LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.00E+01 LW15 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 LW16 R019 Livestock soil intake (kg/day) 5.000E-01 5.00aE-01 LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 MLFD R019 Depth of soil mixing layer (i) 2.300E-01 IM.500E-a1 DM R019 Depth of roots (i) 1.220E+00 I9.0aE-01 DROOT R019I Drinking water fraction from ground water 3 1.aa0E+O0 1.aaaE+O0 FGWDW R019 Household water fraction from ground water not used I1.aoE+00 FGWHH R019w Livestock water fraction from ground water 1.000E+00 1.0OaE+00 FGWLW R019 Irrigation fraction from ground water 1.0a0E+00 1.0300E+00 FGWIR R19B Wet weight crop yield for Non-Leafy (kg/M**2) 1.750E+00 7.000E-01 YV(1)
R19B Wet weight crop yield for Leafy (kg/m*
t
- 2) 2.889E+00 3 1.500E+00 Yv(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 ' 1.100E+00 Yv(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 TE(1)
R1aB Growinn Season for Leafy (vearsl 1.230E-01 2.SOOE-O1 TE(2) t BARTLETT Page 43
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 TE(3)
R19B Translocation Factor for Non-Leafy 1.O00E-01 1.000E-01 a TIV(1)
R19B Translocation Factor for Leafy 1.O00E+00 1.000E+00 TIV(2)
R19B Translocation Factor for Fodder 1.O00E+00 1.O00E+00 a-TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 a-RDRY(1)
R19b Dry Foliar Interception Fraction for Leafy 3.500E-01 2.50OE-01 RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 a 2.500E-01 3 RWET(1)
R19B wet Foliar Interception Fraction for Leafy 5.800E-01 a 2.500E-01 RWET(2)
RI9B Wet Foliar Interception Fraction for Fodder 3.500E-01 a 2.500E-01 RWET(3)
R19B weathering Removal Constant for Vegetation a 3.300E+01 2.000E+01 WLAM C14 C-12 concentration in water (g/cm**3) not used 2.OOOE-05 C12WTR C14 a C-12 concentration in contaminated soil (g/g) not used 3.000-E02 3 C12CZ C14 Fraction of vegetation carbon from soil not used 2.OOOE-02 CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 a CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.OOOE-01 DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 EVSN C14 C-12 evasion flux rate from soil (1/set) not used 1.000E-1O a REVSN C14 Fraction of grain in beef cattle feed not used 8.00OE-01 AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 AVFGS STOR Storage times of contaminated foodstuffs (days):
a STOR Fruits, non-leafy vegetables, and grain a 1.400E+01 1.400E+01 STORT(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 aSTORT(2)
STOR Milk 1.000E+00 1.0OOE+00 STORT(3)
STOR a Meat and poultry 2.000E+01 2.OOOE+Oi STORT(4)
STOR Fish 7.000E+00 a 7.OOOE+00 STOILT(5)
STOR Crustacea and mollusks 7.OOOE+00 7.OOOE+0O STORT(6)
IRESRAD, Version 6.5 T< Limit = 30 days 11/28/2011 09:51 Page 8
Summary : HB soil DCGLCm243 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM243 DCGL\\HB SOIL DCGLCM243.RAD Site-Specific Parameter Summary (continued) 0 3
User 3
Used by RESRAD a Parameter Menu Par Fameter....................
Input a
Default 3.(If different..from user input)
Name STOR a Well water 1.000E+00 1.OOOE+00 STORT(7)
STOR Surface water 1.000E+00 1.OOOE+00 a-STORT(8)
STOR Livestock fodder 4.500E+01 4.5OOE+01 STORT(9)
R021 Thickness of building foundation (m) not used I.SOOE-01 a-FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used a 2.400E+00 DENSFL R021 Total porosity of the cover material not used 4.OOOE-01 TPCV R021 a Total porosity of the building foundation not used 1.000E-01 TPFL RO21 volumetric water content of the cover material not used 5.000E-02 a Pa20CV R021 volumetric water content of the foundation a not used 3.OOOE-02 PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
3 a
R021 in cover material not used a 2.000E-06 a DIFa V R021 in foundation material not used a 3.OOOE-07 DIFFL R021 in contaminated zone soil not used 2.OOOE-06 a DIFCZ R021 a Radon vertical dimension of mixing (m) not used a 2.000E+00 HMIX R021 Average building air exchange rate (1/hr) not used a 5.000E-01 REXG R021 Height of the building (room)
(m) not used 2.500E+00 HRM R021 a Bui d ding interior area factor not used a 0.000E+00 FAI R021 Building depth below ground surface (m) not used a-1.OOOE+00 DMFL R021 a Emanating power of Rn-222 gas not used 3 2.500E-01 EMANA(1)
R021 a Emanating power of Rn-220 gas a not used 1.500E-01 a-EMANA(2)
TITL Number of graphical time points 32 NPTS TITL Maximum number of integration points for dose 17
- 3.
LYMAX TITL a Maximum number of integration points for risk 1
a I
KYMAX Summary of Pathway Selections
.Pathay a
user selection
....... e t...
-- external gamma active 2
inhalation (w/o radon) 3 active 3 --
plant ingestion active 4
meat ingestion a
active 5
milk ingestion active 6
aquatic foods active 7 -- drinking water active 8
soil ingestion active 9 --
radon suppressed Find peak pathway doses a
active IRESRAD, version 6.5 T" Limit = 30 days 11/28/2011 09:51 Page 9
Summary : HB soil DCGL.Cm243 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM243 DCGL\\HB SOIL DCGL.CM243.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area:
30000.00 square meters Cm-243 1.00OE+0O Thickness:
2.67 meters Cover Depth:
0.00 meters
- IRESRAD, Version 6.5 To Limit = 30 days 11/28/2011 09:51 Page 1
probabilistic results summary : HB soil DCGL_Cm243 File : C:\\RESRADFAnILY\\RESRAD\\6.5\\USERFILES\\CM243 DCGL\\HB SOIL DCGLCM243.RAD Table of Contents Part VI: Uncertainty Analysis ttIttflttfftitfitiftilitfifft ORESRAD Uncertainty Analysis Results Probabilistic Input..
2 Total Dose..
4 Total Risk...
5 Dose vs Pathway:
Ground External...................
6 Dose vs Pathway:
Inhalation (w/o Radon)..............
7 Dose vs Pathway:
Radon (water Ind.)..................
8 Dose vs Pathway:
Plant (water Ind.)..................
9 Dose vs Pathway:
Meat (water Ind.)
10 Dose vs Pathway:
Milk (water Ind.).................
11 Dose vs Pathway:
Soil Ingestion.....................
12 Dose vs Pathway:
Water Ingestion....................
13 WBARTLETT Page 44
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Dose vs Pathway:
Fish Ingestion.....................
14 Dose vs Pathway:
Radon (water Dep.)
15 Dose vs Pathway:
Plant (Water Dep.)
16 Dose vs Pathway:
Meat (Water Dep.)
17 Dose vs Pathway:
Milk (water Dep.)
18 Cumulative Probability Summary.......................
19 summary of dose at graphical times, reptition 1...
20 Peak of the mean dose at graphical times.............
21 Correlation and Regression coefficients (if any).....
22 IRESRAD, version 6.5 T" Limit = 30 days 11/28/2011 09:51 Page 2
Probabilistic results summary : HB soil DCGLCm243 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM243 DCGL\\HB SOIL DCGLCM243.RAD Probabilistic Input ONumber of Sample Runs: 2000 Number Name Distribution Parameters AA4W AAAAAAAAAAW A
XXXXXXXXXXXXXXXX xxxxxxxxxxxxxxAx 1
DENSCZ BOUNDED NORMAL 1.5635
.2385
.4 2
TPCZ BOUNDED NORMAL
.41
.09 3
HCCZ BOUNDED LOGNORMAL-N 1.36 2.17
.(
4 BCZ BOUNDED LOGNORMAL-N 1.73
.323 2
5 EVAPTR UNIFORM
.5
.75 6
RI UNIFORM
.36
.76 7
OENSAQ BOUNDED NORMAL 1.5105
.1855 8
TPSZ BOUNDED NORMAL
.43
.0699 9
EPSZ BOUNDED NORMAL
.342
.0705 10 HCSZ BOUNDED LOGNORMAL-N.362 1.59
.(
11 NSZ BOUNDED LOGNORMAL-N 1.96
.265 3
12 DWIBWT TRIANGULAR 6
10 34 13 UW UNIFORM 1173 1973 14
"(1)
UNIFORM 0
8.08 15 DENSUZ(1)
BOUNDED NORMAL 1.5635
.2385
.1 16 TPUZ(1)
BOUNDED NORMAL
.41
.09 17 EPUZ(1)
BOUNDED NORMAL
.315
.0905
.(
18 HCUZ(1)
BOUNDED LOGNORMAL-N 1.36 2.17
.(
19 BUZ(1)
BOUNDED LOGNORMAL-N 1.73
.323 2
20 MLINH CONTINUOUS LINEAR 8
0 0
.00003
.8119
.00004
.9495
.00006
.9937
.000076
.9983 21 SHF3 UNIFORM
.15
.95 22 DM TRIANGULAR 0
.15
.4 23 yW(1)
TRUNCATED LOGNORMAL-N.56
.48
.(
24 WLAM TRIANGULAR 5.1 18 8
25 RWET(2)
TRIANGULAR
.06
.67 26 DCACTC(3)
TRUNCATED LOGNORMAL-N 8.82 1.82
.(
27 DCACTU1(3)
TRUNCATED LOGNORMAL-N 8.82 1.82
.(
28 DCACTS(3)
TRUNCATED LOGNORMAL-N 8.82 1.82
.4 29 DCACTC(1)
TRUNCATED LOGNORMAL-N 6.72 3.22
.4 30 DCACTUI(1)
TRUNCATED LOGNORMAL-N 6.72 3.22
.4 31 DCACTS(1)
TRUNCATED LOGNORMAL-N 6.72 3.22
.4 32 DCACTC(2)
TRUNCATED LOGNORMAL-N 7.28 3.15
.4 33 DCACTU1(2)
TRUNCATED LOGNORMAL-N 7.28 3.15
.(
34 DCACTS(2)
TRUNCATED LOGNORMAL-N 7.28 3.15
.4 35 DCACTC(5)
TRUNCATED LOGNORMAL-N 5.94 3.22
.4 36 DCACTUl(5)
TRUNCATED LOGNORMAL-N 5.94 3.22
.(
37 DCACTS(5)
TRUNCATED LOGNORMAL-N 5.94 3.22
.(
38 DCACTC(6)
TRUNCATED LOGNORMAL-N 6.86 1.89
.4 39 DCACTU1(6)
TRUNCATED LOGNORMAL-N 6.86 1.89
,(
40 DCACTS(6)
TRUNCATED LOGNORMAL-N 6.86 1.89
.4 41 DCACTC(7)
TRUNCATED LOGNORMAL-N 4.84 3.13
.4 42 DCACTU1(7)
TRUNCATED LOGNORMAL-N 4.84 3.13
.(
43 DCACTS(7)
TRUNCATED LOGNORMAL-N 4.84 3.13
.4 44 BRTF(96,2)
TRUNCATED LOGNORMAL-N -10.82 1
.(
45 BRTF(96,3)
TRUNCATED LOGNORMAL-N -13.12
.9
.(
46 BBIO(96,1)
LOGNORMAL-N 3.4 1.1 47 BRTF(89,I)
TRUNCATED LOGNORMAL-N -6.91 1.1
.(
48 BRTF(89,2)
TRUNCATED LOGNORMAL-N -10.82 1
.(
IRESRAD, version 6.5 T" Limit = 30 days 11/28/2011 09:51 Page Probabilistic results summary : HB soil DCGL.Cm243 File : C:\\RESRADIFAMILY\\RESRAD\\6.5\\USERFILES\\CM243 DCGL\\HB SOIL DCGLCM243.RAD Probabilistic Input (cont.)
827 2.3 1319
.6881 00478 3190
.08 15.3 937 2.084 214
.646 124
.56 0106 195
.02 15.5 0
827 1319 0349 00478
.08
.0001 6
001 4
95 001 001 001 001 001 001 001 001 001 001 001 001 001 001 001 001 001 001 001 001 001 001 3
2.3
.6881
.594 3190 15.3
.000008 1
.0151
.000016
.1365
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999 Number Name 49 BRTF(89,3) 50 BBIO(89,1) 51 BRTF(95,1) 52 BRTF(95,2) 53 BRTF(95,3) 54 BBIO(95,1) 55 BRTF(91,1) 56 BRTF(91,2) 57 BRTF(91,3) 58 BBIO(91,1) 59 BRTF(94,1) 60 BRTF(94,2) 61 BRTF(94,3) 62 BBIO(94,1) 63 BRTF(92,1) 64 BRTF(92,2) 65 BRTF(92,3) 66 BBIO(92 1)
Ittt3 ttItttittittttniitttti Distribution Parameters TRUNCATED LOGNORMAL-N -13.12
.9
.001
.999 LOGNORMAL-N 2.7 1.1 TRUNCATED LOGNORMAL-N -6.91
.9
.001
.999 TRUNCATED LOGNORMAL-N
-9.9
.2
.001
.999 TRUNCATED LOGNORMAL-N -13.12
.7
.001
.999 LOGNORMAL-N 3.4 1.1 TRUNCATED LOGNORMAL-N
-4.61 1.1
.001
.999 TRUNCATED LOGNORMAL-N -12.21 1
.001
.999 TRUNCATED LOGNORMAL-N -12.21
.9
.001
.999 LOGNORMAL-N 2.3 1.1 TRUNCATED LOGNORMAL-N
-6.91
.9
.001
.999 TRUNCATED LOGNORMAL-N -9.21
.2
.001
.999 TRUNCATED LOGNORMAL-N -13.82
.5
.001
.999 LOGNORMAL-N 3.4 1.1 TRUNCATED LOGNORMAL-N
-6.21
.9
.001
.999 TRUNCATED LOGNORMAL-N -7.13
.7
.001
.999 TRUNCATED LOGNORMAL-N -7.82
.6
.001
.999 LOGNORMAL-N 2.3 1.1 ItltitGN iMLit-N 11t 2.1113 11.1111111111111111 1RESRAD 1 Version 6.5 Ta Limit = 30 days 11/28/2011 09:51 Page 21 Probabilistic results summary : HB soil DCGLCm243 File : C:\\RESRAD.FAMILY\\RESRAD\\6.5\\USERFILES\\CM243 DCGL\\HB SOIL DCGLCM243.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1
0.OOOE+00 8.611E-01 Q10BARTLETT Page 45
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 Cm-244 Results:
IRESRAD, Version 6.5 T1< Limit = 30 days 11/28/2011 17:38 Page 1
Summary HR soil DCGLCm244 File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM244 DCGL\\HB SOIL DCGL_CM244.RAD Table of Contents Part I: Mixture Sums and Sinqle Radionuclide Guidelines ffffltlttiffifilffff11ifftt Ifffti11ffff1ltif*i1ffi1ifft Dose Conversion Factor (and Related) Parameter Summary...
2 Site-Specific Parameter Summary............................
4 Summary of Pathway Selections..............................
8 Contaminated zone and Total Dose Summary...................
9 Total Dose Components Time.= O.000E+00......................................
10 Time = 1.OOOE+00.....................................
11 Time = 3.OOOE+00.....................................
12 Time = 1.OOOE+01.....................................
13 Time = 3.OOOE+01.....................................
14 Time = 1.OOOE+02..
15 Time = 3.OOOE+02..
16 Time = i.OOOE+03....................................
17 Dose/Source Ratios Summed Over All Pathways..............
18 Single Radionuclide Soil Guidelines......................
18 Dose Per Nuclide Summed Over All Pathways.................
19 Soil Concentration Per Nuclide...........................
19 IRESBAD, Version 6.5 T. Limit = 30 days 11/28/2011 17:38 Page 2
Summary : HR soil DCGLCm244 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM244 DCGL\\HB SOIL DCGLCM244.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: HB DCGLs Plus FGR 12 & FGR 11 0
3 3 current a
Base a Parameter Menu 3 Parameter 3
Value#
.Case*.
a Name A-1 DCFs for external ground radiation, (mrem/yr)/(pCi/g)
A-1 AC-228 (Source: FGR 12) 5.978E+00 5.978E+00 DCFi(
1)
A-1 Bi-212 (Source: FGR 12) 1.171E+00 1.171E+00 DCF1(
2)
A-1 Cm-244 (Source:
FGR 12) 1.259E-04 1.259E-04 DCFi(
3)
A-1 Pb-212 (Source:
FGR 12) 7.043E-01 7.043E-01 DCF1(
4)
A-1 a Po-212 (Source: FGR 12) 0.O00E+00 O.OOOE+00 DCF1(
5)
A-1 a Po-216 (Source: FGR 12) 1.042E-04 1.042E-04 DCFI(
6)
A-1 a Pu-240 (Source:
FGR 12) 1.467E-04 a 1.467E-04 a DCFI(
7)
A-1 Ra-224 (Source:
FGR 12) 5.119E-02 a 5.119E-02 a DCFI(
8)
A-1 a Ra-228 (Source:
FGR 12) 0.0000E+0a 0.O000E+00 DCFI(
9)
A-1 a Rn-220 (Source: FGR 12) a 2.298E-03 a 2.298E-03 DCF1( 10)
A-1 a Th-228 (Source: FGR 12) 7.940E-03 a 7.940E-03 DCFI( 11)
A-1 a Th-232 (Source:
FGR 12) 5.212E-04 a 5.212E-04 a DCFi( 12)
A-1 Tl-208 (Source:
FGR 12) 2.298E+01 a 2.298E+01 a DCFI( 13)
A-1 u-236 (Source: FGR 12) 2.148E-04 2.148E-04 DCFI( 14)
B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Cm-244 a 2.480E-01 2.480E-01 DCF2(
1)
B-1 a Pu-240 4.290E-01 4.290E-01 DCF2(
4)
B-1 Ra-228+D 5.078E-03 4.770E-03 DCF2(
6)
B-1 Th-228+D 3.454E-01 3.420E-01 a DCF2(
7)
B-i Th-232 1.640E+00 1.640E+00 a DCF2(
8)
B-1 u-236 1.250E-01 1.250E-01 DCF2(
9)
D-i Dose conversion factors for ingestion, mrem/pCi:
a D-1 Cm-244 2.020E-03 2.020E-03 DCF3(
1)
D-1 Pu-240 3.540E-03 a 3.540E-03 DCF3(
4)
D-1 Ra-228+D 1.442E-03 1.440E-03 DCF3(
6)
D-1 Th-228+D 8.086E-04 3.960E-04 DCF3(
7)
D-1 Th-232 2.730E-03 2.730E-03 DCF3(
8)
D-1 u-236 2.690E-04 2.690E-04 DCF3(
9)
D-34 Food transfer factors:
D-34 Cm-244 plant/soil concentration ratio, dimensionless 1.830E-03 i.OOOE-03 RTF(
1,1)
D-34 Cm-244 beef/livestock-intake ratio, (pci/kg)/(pCi/d) 2.000E-05 a 2.OOOE-0S RTF(
1,2)
D-34 a Cm-244 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.000E-06 2.OOOE-06 RTF(
1,3)
D-34 a D-34 Pu-240 plant/soil concentration ratio, dimensionless 1.830E-03 a 1.OOE-03 RTF(
4,1)
D-34 Pu-240 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-04 a 1.OOOE-04 RTF(
4,2)
D-34 a Pu-240 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.000E-06 a 1.000E-06 RTF(
4,3)
D-34 a D-34 Ra-228+D
,plant/soil concentration ratio, dimensionless 4.000E-02 a 4.000E-02 a RTF(
6,1)
D-34 a Ra-228+D beef/livestock-intake ratio, (pCi/kg)/(pci/d) 1.000E-03 a 1.000E-03 a RTF(
6,2)
D-34 Ra-228+D milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.000E-03 a 1.000E-03 RTF(
6,3)
D-34 a
D-34 Th-228+D
, olant/soil concentration ratio, dimensionless 1.000E-03 a 1.000E-03 a RTF(
7,1)
D-34 a Th-228+D beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-04 a 1.000E-04 RTF(
7,2)
D-34 Th-228+D milk/livestock-intake ratio, (pCi/L)/(pCi/d) 5.000E-06 5.OOOE-06 RTF(
7,3)
D-34 IRESRAD, Version 6.5 T< Limit = 30 days 11/28/2011 17:38 Page 3
Summary : HB soil DCGL_Cm244 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM244 DCGL\\HB SOIL DCGLCM244.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)
Dose Library: HB DCGLS Plus FGR 12 & FGR 11 0
3 Current I
Base Parameter Menu a parametervalue#
a Caset 3
Name D-34 a Th-232
, plant/soil concentration ratio, dimensionless I.OOOE-03 1.O000E-03 a RTF(
8,1)
D-34 a Th-232 beef/livestock-intake ratio, (pCi/kg)/(pCi/d)
O1.OOE-04.000E-04 RTF(
8,2)
D-34 a Th-232 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 5.OOOE-06 5.000E-06 RTF(
8,3)
D-34 a
D-34 a u-236
, plant/soil concentration ratio, dimensionless a 2.500E-03 a 2.500E-03 RTF(
9,1)
D-34 u-236 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 3.400E-04 3.400E-04 RTF(
9,2)
D-34 u-236 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 6.000E-04 6.000E-04 RTF(
9,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Cm-244
, fish 3.000E+01 3.OOOE+01 BIOFAC(
1,1)
D-5 a Cm-244
, crustacea and mollusks 1.000E+03 1.000E+03 BIOFAC(
1,2)
D-5 a
o-5 a Pu-240
, fish 3.000E+01 3.000E+01 BIOFAC(
4,1) tI BARTLETT Page 46
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 D-5 Pu-240
, crustacea and mollusks 1.O00E+02 1.O0OE+02 BIOFAC(
4,2)
D-5 D-5 Ra-228+D
, fish 5.000E+01 5.000E+01 BIOFAC(
6,1)
D-5 Ra-228+D
, crustacea and mollusks 2.50OE+02 2.50OE+02 BIOFAC(
6,2)
D-5 D-5 Th-228+D
, fish 1.OOOE+02
' 1.OOOE+02 BIOFAC(
7.1)
D-5 Th-228+D
, crustacea and mollusks 5.OOOE+02 5.OOOE+02 BIOFAC(
7,2)
D-5 D-5 Th-232
, fish 1.O00E+02
' 1.OOOE+02 BIOFAC(
8,1)
D-5 Th-232
, crustacea and mollusks 5.OOOE+02 5.OO0E+02 BIOFAC(
8,2)
D-5 D-5 U-236
, fish 1.OooE+01 1.OOOE+01 BIOFAC(
9,1)
D-5 u-236
. crustacea and mollusks 6.O0OE+O1 6.OOOE+01 BIOFAC(
9 2)
- For DCFl(Xxx) only, factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Default.Lib W/o Associate Nuclide contributions.
1RESRAD, version 6.5 T'c Limit = 30 days 11/28/2011 17:38 Page 4
Summary : HB soil DCGLCm244 File C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\CM244 DCGL\\HB SOIL DCGLCM244.RAD 0
menu Parameter ROll Area of contaminated zone (m**2)
ROll Thickness of contaminated zone (m)
R011 Fraction of contamination that is submer ROll Length parallel to aquifer flow (m)
R011 Basic radiation dose limit (mrem/yr)
ROll Time since placement of material (yr)
ROll Times for calculations (yr)
ROll Times for calculations (yr)
ROll Times for calculations (yr)
ROll Times for calculations (yr)
ROll Times for calculations (yr)
ROll Times for calculations (yr)
ROll Times for calculations (yr)
ROll Times for calculations (yr)
R011 Times for calculations (yr)
R012 Initial principal radionuclide (pci/g):
R012 Concentration in groundwater CpCi/L):
ROll Cover depth (m)
ROll Density of cover material (g/cm**3)
ROll Cover depth erosion rate (m/yr)
R013 Density of contaminated zone (g/cm**3)
R013 Contaminated zone erosion rate (m/yr)
ROll Contaminated zone total porosity R013 Contaminated zone field capacity R013 Contaminated zone hydraulic conductivity R013 Contaminated zone b parameter R013 Average annual wind speed (m/sec)
ROll Humidity in air (g/m**3)
R013 Evapotranspiration coefficient R013 Precipitation (m/yr)
R013 Irrigation (m/yr)
R013 Irrigation mode R013 Runoff coefficient RO13 watershed area for nearby stream or pond R013 Accuracy for water/soil computations R014 Density of saturated zone (g/cm**3)
R014 Saturated zone total porosity R014 Saturated zone effective porosity R014 Saturated zone field capacity RO4 Saturated zone hydraulic conductivity (m.
R014 3 Saturated zone hydraulic gradient R014 3 Saturated zone b parameter R014 Water table drop rate (m/yr)
R014 well pump intake depth (m below water ta R014 Model: Nondispersion (ND) or Mass-Balanc R014 well pumping rate (m**3/yr)
Site-specific Parameter Summary User I
used by RESRAD Parameter 3 Input 3Default 3(If different from user input) 3 Name
- " u *.......D a ]....*.*
.4.* e r n....
3.OOOE+04 1.000E+04 AREA 2.670E+00 2.OOOE+O0 THICKO ged O.OOOE+00 O.OOOE+OO SUBMFRACT 1.9SOE+02 31.000E+02 LCZPAQ 2.SO0E+O1 3.OOOE+O3 BRDL O.OOO+00 O.O0OOE+OO TI I.OOOE+00 1.OOOE+O0 T(
2) 3.OOOE+O0 3.OOE+O0 T( 3) 1.OOOE+O1 1.000E+01 T(
4) 3.OOOE+01 3.OOOE+OI T( 5) 3IOOOE+02 1.00OE+02 T(
6) 3.OOOE+02 3.OOOE+02 T( 7)
I.OOOE+03 1.OOOE+03 T( 8) not used 0.O0OE+O0 T(
9) not used O.OOOE+0O T(1O)
Cm-244 l.OOOE+O0 O.OOOE+OO S1(1)
Cm-244 not used O.OOE+OO wl(
1)
O.OOOE+00 O.OOE+OO COVERO not used 1.500E+OO DENSCV not used 1.OOOE-03 vCV 1.564E+00 1.SOOE+O0 DENSCZ 2.200E-03 l.OOOE-03 VCZ 4.10OE-O1 4.OOOE-O1 TPCZ 9.500E-02 2.OOOE-O1 FCCZ (m/yr) 3.900E+00 1.OOOE+01 HCCZ S.600E+00 5.300E+O0 BCZ 3.040E+00 2.OOOE+O0 WIND not used 8.0OOE+O0 HUMID 6.250E-01 5.OOOE-O1 EVAPTR 9.100E-01 1.OOOE+O0 PRECIP 5.600E-01 2.OOOE-Ol RI overhead overhead IDITCH 3 S.OOOE-01 2.OOOE-OI RUNOFF (m**2) 3 2.520E+07 3 1.OOOE+06 3 WAREA 1.0OOE-03 1.0OOE-03 EPS
' 1.510E+00 : 1.500E+00 DENSAQ 4.300E-O1 4.OOOE-01 TPSZ 3 3.420E-01 2.00OE-O1 EPSZ 8.800E-02 2.OOOE-01 FCSZ
/yr) 2.880E+01 1.OOOE+02 HCSZ 2.OOOE-03 2.OOOE-02 HGWT 7.1OOE+O0 5.300E+O0 BSZ 1.OOOE-03 1.OOOE-03 VwT ble) 1.OOOE+01 1.000E+O1 DWIB*T e (MB)
ND ND MODEL 1.573E+03 2.500E+02 Uw uAAA 1RESRAD, Version 6.5 T-Limit = 30 days 11/28/2011 17:38 Page 5
Summary : HB soil DCGLCm244 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM244 DCGL\\HB SOIL DCGLCM244.RAD Site-Specific Parameter Summary (continued) 3 menu Parameter R015 Number of unsaturated zone strata R015 Unsat. zone 1, thickness (m)
R015 Unsat. zone 1, soil density (g/cm**3)
R015 Unsat. zone 1, total porosity R015 Unsat. zone 1, effective porosity R015 unsat. zone 1, field capacity R015 Unsat. zone 1, soil-specific b parameter R01S Unsat. zone 1, hydraulic conductivity (m/yr)
RO16 Distribution coefficients for Cm-244 R016 3 Contaminated zone (cm**3/g)
R016 unsaturated zone I (cm**3/g)
R016 Saturated zone (cm**3/g)
R016 Leach rate (/yr)
R016 solubility constant R016 Distribution coefficients for daughter Pu-240 ROI6 Contaminated zone (cm *3/g)
R016 Unsaturated zone 1 Ccmm3/g**
R016 Saturated zone (cm m 3/g)
R016 Leach rate (/yr)
ROI6 solubility constant R016 Distribution coefficients for daughter Ra-228 R016 Contaminated zone (cmc*3/g)
R016 Unsaturated zone I (cm**3/g)
R016 Saturated zone (cm**3/g)
R016 Leach rate (/yr)
R016 solubility constant t
BARTLETT input 3Default 3(if different from user input) 3 Name
- X~iSXXXAXkAXXX~XXXXAXXXWXXXXX~
AAAA AAAmAAAAAXXWAAAAAAAAXX 31
.1 3
4.040E+00 4.OO0E+003 3 1.564E+00 1.5OOE+00 3 4.100E-01 4.OOOE-01 I 3.150E-01 2.OOOE-01 9.500E-02 2.OOOE-Ol 5.600E+00 5.300E+00 3.900E+00 l.OooE+Ol 6.761E+03 '-I.OOOE+O0 6.761E+03 '-1.O00E+O0 6.761E+03 3 -l.OOOE+O0 O.OOOE+0O O.0OOE+OO O.OOOE+OO O.OOOE+-O 3 9.530E+02 2.OOOE+03 9.530E+02 2.OOOE+03 9.530E+02 2.OOOE+03 O.OOOE+OO O.0OOE+O0 O.OOOE+00 O0.0OE+O0 :
3.533E+03 7.000E+O1 3.533E+03 I 7.OOOE+O1 3 3.533E+03 7.00OE+OI 0.OOOE+00 O.O0OE+0O O.OOOE+0O ' 0.O0OE+00 1.349E-05 not used 9.565E-05 not used 2.581E-05 not used NS SH(1)
DENSUZ(1)
TPUZ(l)
EPUZ(1)
FCUZ(1)
BUZ(1)
HCUZ(l)
DCNUCC( 1)
DCNUCU( 1,1)
DCNUCS( 1)
ALEACH( 1)
SOLUBK(
1)
DCNUCC( 4)
DCNUCU( 4,1)
DCNUCS( 4)
ALEACH( 4)
SOLUBK( 4) 3 DCNUCC( 6)
DCNUCU( 6,1)
DCNUCS( 6)
ALEACH( 6)
SOLUBK( 6)
Page 47
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R016 Distribution coefficients for daughter Th-228 R016 a Contaminated zone (cm**3/g) 3-NaN 6.OODE+04 I R016 unsaturated zone 1 (cm**3/g) a-NaN 6.OOE+04 R016 Saturated zone (cm**3/g) a-NaN 6.OE+04 R016 Leach rate (/yr) 5 -NaN a 0.DOE+00 R016 solubility constant 5.DOOE+DO O.O0011+O0 RD16 Distribution coefficients for daughter Th-232 a
a R016 Contaminated zone (cn**3/g) a 5.884E+03 6.00oE+04 RO16 unsaturated zone 1 (cm**3/g) 5.884E+03 6.000E+04 R016 Saturated zone (cm**3/g) a 5.884E+03 6.000E+04 R016 Leach rate (/yr)
O.OooE+O0 a0.000E+O0 a
R016 a solubility constant O.a000E+00
.O.000E10a R016 a Distribution coefficients for daughter U-236 a
a RO16 Contaminated zone (cm**3/o) 1.260E+02 5.O00OE+O1 R016 a unsaturated zone 1 (cm**3/g) a 1.260E+02 a 5.OD0E+O1 R016 a Saturated zone (cm**3/g) a 1.260E+02 a 5.O00E+O1 R016 Leach rate C/yr) a O.OOOE+O0 a.O00E+Oa R016 a Solubility constant O.O00E+O0 a O.OOOE+O0 1RESRAD, Version 6.5 To Limit = 30 days 11/28/2011 17:38 Page 6
Summary HB soil DCGLCm244 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM244 DCGL\\HB SOIL DCGLCM244.RAD Sol.
Kd =-NAN
- 1. 550E-05 not used 7.224E-04 not used 3
used 3
3 3
3 3
3 3
DCNUCC( 7)
DCNUCU( 7,1)
DCNUCS(
7)
ALEACH(
7)
SOLUBK( 7)
DCNUCC(
8)
DCNUCU( 8,1)
DCNUCS(
8)
ALEACH(
8)
SOLUBK(
8)
DCNUCC( 9)
DCNUCU( 9,1)
DCNUCS( 9)
ALEACH( 9)
SOLUBK( 9) 0 a
menu a Pa3ee R017 a Inhalation rate (m**3/yr)
R017 a Mass loading for inhalation (g/m**
ROl7 a Exposure duration R017 a Shielding factor, inhalation R017 Shielding factor, external gamma R017 Fraction of time spent indoors ROl7 Fraction of time spent outdoors (o ROl7 a Shape factor flag, external gamma ROl7 Radii of shape factor array (used R017 Outer annular radius (m),
ring R017 Outer annular radius (m),
ring R017 Outer annular radius (m),
ring R017 a Outer annular radius (m),
ring R017 a Outer annular radius (m),
ring ROll a Outer annular radius (m),
ring R017 Outer annular radius (m),
ring R017 Outer annular radius (m),
ring R017 Outer annular radius (m),
ring ROl7 outer annular radius (m),
ring 1 R017 a outer annular radius (m),
ring 1 R017 Outer annular radius (m),
ring 1 ROl7 Fractions of annular areas within ROl7 Ring 1
ROl7 Ring 2
ROl7 Ring 3
R017 Ring 4
ROl7 Ring 6
R017 Ring 7
R017 3 Ring 7
RO17 Ring 8
RO17 Ring 9
ROl7 Ring 10 ROl7 Ring 11 ROl7 Ring 12 R018 Fruits, vegetables and grain consui RO8 Leafy vegetable consumption (kg/yr R018 a Milk consumption (L/yr)
ROl a Meat and poultry consumption (kg/y R018 a Fish consumption (kg/yr)
R018 a other seafood consumption (kg/yr)
R018 a Soil ingestion rate Cg/yr)
R018 a Drinking water intake (L/yr)
R018 Contamination fraction.of drinking R018 a Contamination fraction of househol R018 a Contamination fraction of livestoc R018 a Contamination fraction of irrigati R018 Contamination fraction of aquatic R018 Contamination fraction of plant fo
- 1RESRAD, Version 6.5 To Limit = 30 da Summary : MB soil DCGL.Cm244 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USE 0
a menu aParameter RO18 Contamination fraction of meat RO18 Contamination fraction of milk R019 Livestock fodder intake for meat C R019 Livestock fodder intake for milk R019 a Livestock water intake for meat (L R019 a Livestock water intake for milk (L R019 Livestock soil intake (kg3/day)
R019 Mass loading for foliar deposition R019 a Depth of soil mixing layer (m)
R019 Depth of roots Cm)
R019 Drinking water fraction from groun R019 a Household water fraction from grou R019 a Livestock water fraction from grou R019 a Irrigation fraction from ground wa R19B wet weight crop yield for Non-Leaf R19B wet weight crop yield for Leafy R19B wet weight crop yield for Fodder R19B Growing Season for Non-Leafy (yea R19B Growing Season for Leafy (yea R19B Growing Season for Fodder (yea R19B Translocation Factor for Non-Leaf R198 Translocation Factor for Leafy CBARTLETT Site-Specific Parameter Summary (continued) a User a
used by RESRAD Parameter a
- p*L Default a (if different rom user input)
Name a 8.400E+03 8.400E+03 INHALR
- 3) 1.O00E-04 a 1.OOOE-04 MLINH 3.OOOE+01 a 3.OOOE+01 ED 5.500E-01 4.OOOE-01 a-SHF3 2.725E-01 7.OOOE-O1 a-a SHF1 a 6.571E-01 5.O0OE-Ol a-a FIND n site) a 1.181E-01 a 2.500E-01 FOTD 1.000E+O0 a 1.OOOE+0O a
>0 shows circular AREA.
FS if FS 1:
3 not used 5.OOOE+O1 aRADSHAPE(
1) 2:
not used a 7.071E+01 a RADSHAPE(
2) 3:
not used O.OOOE+O0 RADSHAPE(
3) 4:
not used a O.OOOE+O0 a---
a RADSHAPE(
4) 5" not used a O.OOOE+O0 a-ADRSHAPE(
5) 6:
not used a 0.000E+00 a---
a RAD.SHAPE(
6) not used a
.000.E+O0 a
a RADSHAPEC 7) 8 a not used 0.OOOE+00 RAD_SHAPE( 8) 9:
not used O.OOOE+00 RADSHAPE(
9) 0:
not used O.O0OE+O0 RADSHAPE(1O) a: not used a 0.OOOE+00 RADSHAPE(11) 2:
not used O.O00E+00 3AD_.SHAPE(12)
AREA:
not used a 1.000E+00 FRACA( 1) not used a 2.732E-01 FRACA( 2) not used a O.O0OE+00 PRACA( 3) a not used 0.0OOE+00 FRACAC 4) not used
.OOOE+O0 FPACA( 5) not used 0.OOOE+00 FPRACA( 6) not used
.OOOE+00 FRACA( 7) not used O.OOOE+00 FRACA( 8) not used O.OOOE+00 a-a FRACA( 9) a not used a O.O0OE+0 0 FRACA(10) not used 0.000E+0O a--
FRACA(11) not used O.OOOE+00 FPRACA(12) mption (kg/yr) 1.120E+02 1.600E+02 a DIET(1) a 2.140E+01 a 1.400E+01 DIET(2) a 2.330E+02 a 9.200E+01 DIET(3) r)
a 6.510E+01 a 6.300E+01 DIET(4) a 2.060E+01 5.400E+O0 DIET(5) a 9.000E-01 a 9.OOOE-01 DIET(6) a 1.826E+01 a 3.650E+01 SOIL a 4.785E+02 a 5.100E+02
'DW water a 1.00OE+00 a 1.OOOE+00 FDW d water a not used a 1.OOOE+00 aa-FHHW k water 1.OOOE+00 1.OOOE+0O FLW on water 1.000E+00
.O00E1O0 FIRW food 1.000E+00 5.OOOE-0l a
FR9 od a 1.000E+00
-1 a
FPLANT ys 11/28/2011 17:38 Page 7
RFILES\\CM244 DCGL\\HB SOIL DCGLCM244.RAD Site-Specific Parameter Summary (continued)
User a
used by RESRAD Parameter a
Inp.t a
Default a.(If different from..se..rinpu)..
5 Name 1.000E+00 a-1 FMEAT a 1.00OE+00 a-1 a-aFMILK kg/day) a 2.710E+01 6.800E+01 LFI5 kg/day) 6.320E+01 5.500E+01 aa LFI6
/day) 5.060E+01 5.OOOE+01 a-a LW15
/day) a 6.000E+01 1.600E+02 a
LWi6 5.OOOE-01 5.000E-01 a LSI (g/m**3) 4.OOOE-04 I.OOOE-04 a-a MLFD 2.300E-01 1.500E-01 a DM 1.220E+00 9.00OE-01 a DROOT d water 1.000E+00
.100OE+00 a--FGWDW nd water a not used a 1.000E+00 FGWHH nd water a.OOOE+O0 ' 1.00EO0 FGWLW ter 1.000E+00 a 1.00OE+O0 a--PFGWIR y (kg/m**2) 1.750E+00 7.000E-01 a YV(l)
(kg/m**2) 2.889E+00 1.500E+00 a YV(2)
(kg/m**2) 1.887E+00 a 1.100E+00 YV(3) rs) 2.460E-01 a 1.700E-01 a-a TE(1) rs) a 1.230E-01 a 2.500E-0l TE(2) rs) 8.200E-02 8.OOOE-02 a-a TE(3) y 1.0OOE-01 l.OOOE-01 a-a TIV(1) a 1.000E+00 1.OOOE+00 a-a TIV(2)
AA o
Page 48 Page 48
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 3 TIV(3)
R198 Dry Foliar Interception Fraction for Non-Leafy 3.S0OE-01 2.500E-01 RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 RDRY(3)
R1gB Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.50OE-01 RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 RWET(3)
R19B Weathering Removal Constant for vegetation 3.300E+01 2.O0OE+01 WLAM C14 C-12 concentration in water (g/cm**3) not used 2.OOOE-05 C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3 3.D00E-02 I C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.0OOE-01 3 DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 3 EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.0OOE-10 I REVSN C14 Fraction of grain in beef cattle feed 3 not used 8.000E-01 3 AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 3 AVFGS STOR Storage times of contaminated foodstuffs (days):
2 STOR 3 Fruits, non-leafy vegetables, and grain I 1.400E+01 1.400E+01 3 3 STOR-T(1)
STOR Leafy vegetables 3 1.000E+0O 1.000E+00 3 STOR.T(2)
STOR 3 Milk 2 1.O00E+00 3 1.00OE+00 STORT(3)
STOR Meat and poultry 2.000E+01 2.00OE+01 2 STOR-T(4)
STOR 3 Fish 7.OOOE+0O 7.000E+00 2 2-STORT(5)
STOR 3 Crustacea and mollusks I 7.000E+00 3 7.O00E+00 STORLT(6)
IRESRAD, Version 6.5 T. Limit = 30 days 11/28/2011 17:38 Page 8
Summary : HB soil DCGLCm244 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM244 DCGL\\HB SOIL DCGLCM244.RAD Site-Specific Parameter Summary (continued) 0 3
2 User 2
2 Used by RESRAD 3
Parameter Menu 3Parameter 2
input 2 Default 2(if different from user input) 3 Name STOR 2
Well water 3 1.OOOE+00 3 1.000E+00 2-2STORT(7)
STOR 3 Surface water 1.000E+00 I 1.000E+00 STORT(8)
STOR 3 Livestock fodder 4.500E+01 4.500E+01 3 STOT(9)
R021 2 Thickness of building foundation (m) 3 not used 3 1.500E-01 FLOOR1 R021 3 Bulk density of building foundation (g/cm**3) not used 2.400E+O0 3 2 DENSFL R021 3 Total porosity of the cover material not used 4.O00E-01 TPCV R021 3 Total porosity of the building foundation 3 not used 1.000E-01 3 TPFL R021 3 volumetric water content of the cover material 3 not used 3 5.0OOE-02 PH2OCV R021 3 volumetric water content of the foundation not used 2 3.000E-02 PH2OFL R021 I Diffusion coefficient for radon gas (m/sec):
2 R021 3 in cover material I not used I 2.000E-06 DIFCV R021 3 in foundation material 3 not used 3 3.000E-07 DIFFL R021 3 in contaminated zone soil 2 not used 3 2.000E-06 3 DIFCZ R021 3 Radon vertical dimension of mixing (m) 2 not used 3 2.0000E+0 2--
HMIX R021 3 Average building air exchange rate (1/hr)
I not used 3 5.DOOE-01 REXG R021 3 Height of the building (room)
(m)
I not used 3 2.500E+00 HRM R021 3 Building interior area factor I not used 3 0.000E+OO 3 FAI R021 3 Building depth below ground surface (m)
I not used 3-1.0OOE+00 DMFL R021 3 Emanating power of Rn-222 gas not used 3 2.500E-01 EMANA(1)
R021 3 Emanating power of Rn-220 gas I not used 3 1.500E-01 EMANA(2)
TITL 2 Number of graphical time points 32 2
2...NPTS TITL 3 Maximum number of integration points for dose 2
17 2
2 2 LYMAX TITL 3 Maximum number of integration points for risk 1
1 22 KYMAX ifliffiifiifflff iifittIiflflt1 tiffiitlftifffflt*1 1
1tI 1tllffffiiflftfftfifilt ff1*11 tflffifff Summary of Pathway Selections
.Pathway 2
user selection external gamma 2
active 2
inhalation (w/o radon) 2 active 3-- plant ingestion 3
active 4
meat ingestion 3
active milk ingestion 2
active 6
aquatic foods 3
active 7 -- drinking water 3
active 8
soil ingestion active 9 --
radon 3
suppressed Find peak pathway doses 2
active lifffitl ff fiftt IItfti Itt~I fifttffffffif IRESRAD, Version 6.5 T-Limit = 30 days 11/28/2011 17:38 Page 9
Summary : HB soil DCGLCm244 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\CM244 DCGL\\HB SOIL DCGLCM244.RAD Contaminated Zone Dimensions Initial soil Concentrations..pCi/g Area:
30000.00 square meters Cm-244 1.000E+00 Thickness:
2.67 meters Cover Depth:
0.00 meters IRESRAD, Version 6.5 T1 Limit = 30 days 11/28/2011 17:38 Page I
Probabilistic results summary : HB soil DCGLCm244 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM244 DCGL\\HB SOIL DCGLCM244.RAD Table of Contents Part VI: Uncertainty Analysis tft11tfItttfttftttt1f1tM/t/
ORESRAD Uncertainty Analysis Results Probabilistic Input..
2 Total Dose...
4 Total Risk...
5 Dose vs Pathway:
Ground External 6
Dose vs Pathway:
Inhalation (w/o Radon) 7 Dose vs Pathway:
Radon (Water Ind.)
8 Dose vs Pathway:
Plant (Water Ind.)................
9 Dose vs Pathway:
Meat (Water Ind.)
10 Dose vs Pathway:
Milk (Water Ind.)................
11 Dose vs Pathway:
Soil Ingestion.....................
12 Dose vs Pathway:
Water Ingestion....................
13 Dose vs Pathway:
Fish Ingestion.....................
14 Dose vs Pathway:
Radon (Water Dep.)
15
- f.
BARTLETT Page 49
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Dose vs Pathway:
Plant (Water Dep.)
16 Dose vs Pathway:
Meat (Water Dep.)
17 Dose vs Pathway:
Milk (Water Dep.)
18 Cumulative Probability Summary.......................
.19 Summary of dose at graphical times, reptition 1.....
20 Peak of the mean dose at graphical times.............
21 Correlation and Regression coefficients (if any).....
22 IRESRAD, Version 6.5 Ta Limit = 30 days 11/28/2011 17:38 Page 2
Probabilistic results summary : HB soil DCGLCm244 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM244 DCGL\\HB SOIL DCGL.CM244.RAD Probabilistic Input ONumber of Sample Runs: 2000 Number Name Distribution Parameters MA X AAA XAAAAA'AAAAAAAAAa X
X"A AAAAAAAAAAAAAAaX,X XXXXXXXXXX 1
DENSCZ ROUNDED NORMAL 1.5635
.2385
.827 2.3 2
TPCZ ROUNDED NORMAL
.41
.09
.1319
.6881 3
HCCZ ROUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 4
BCZ ROUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 5
EVAPTR UNIFORM
.5
.75 6
RI UNIFORM
.36
.76 7
DENSAQ ROUNDED NORMAL 1.5105
.1855
.937 2.084 8
TPSZ ROUNDED NORMAL
.43
.0699
.214
.646 9
EPSZ BOUNDED NORMAL
.342
.0705
.124
.56 10 HCSZ ROUNDED LOGNORMAL-N.362 1.59
.0106 195 11 BSZ ROUNDED LOGNORMAL-N 1.96
.265 3.02 15.5 12 DWIBWT TRIANGULAR 6
10 30 13 Uw UNIFORM 1173 1973 14 H(1)
UNIFORM 0
8.08 15 DENSUZ(1)
BOUNDED NORMAL 1.5635
.2385
.827 2.3 16 TPUZ(1)
ROUNDED NORMAL
.41
.09
.1319
.6881 17 EPUZ(1)
BOUNDED NORMAL
.315
.0905
.0349
.594 18 HCUZ(1)
BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 19 BUZ(1)
ROUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 20 MLINH CONTINUOUS LINEAR 8
0 0
.000008
.0151
.00003
.8119
.00004
.9495
.00006
.9937
.000076
.9983
.0001 1
21 SHF3 UNIFORM
.15
.95 22 SHF1 BOUNDED LOGNORMAL-N -1.3
.59
.044 1
23 DM TRIANGULAR 0
.15
.6 24 Yv(1)
TRUNCATED LOGNORMAL-N.56
.48
.001
.999 25 WLAM TRIANGULAR 5.1 18 84 26 RWET(2)
TRIANGULAR
.06
.67
.95 27 DCACTC(1)
TRUNCATED LOGNORMAL-N 8.82 1.82
.001
.999 28 DCACTU1(1)
TRUNCATED LOGNORMAL-N 8.82 1.82
.001
.999 29 DCACTS(1)
TRUNCATED LOGNORMAL-N 8.82 1.82
.001
.999 30 DCACTC(4)
TRUNCATED LOGNORMAL-N 6.86 1.89
.001
.999 31 DCACTU1(4)
TRUNCATED LOGNORMAL-N 6.86 1.89
.001
.999 32 DCACTS(4)
TRUNCATED LOGNORMAL-N 6.86 1.89
.001
.999 33 DCACTC(6)
TRUNCATED LOGNORMAL-N 8.17 1.7
.001
.999 34 DCACTU1(6)
TRUNCATED LOGNORMAL-N 8.17 1.7
.001
.999 35 DCACTS(6)
TRUNCATED LOGNORMAL-N 8.17 1.7
.001
.999 36 DCACTC(7)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001
.999 37 DCACTU1(7)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001
.999 38 DCACTS(7)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001
.999 39 DCACTC(8)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001
.999 40 DCACTUI(8)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001
.999 41 DCACTS(8)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001
.999 42 DCACTC(9)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001
.999 43 DCACTU1(9)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001
.999 44 DCACTS(9)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001
.999 45 BRTF(96,2)
TRUNCATED LOGNORMAL-N -10.82 1
.001
.999 46 BRTF(96,3)
TRUNCATED LOGNORMAL-N -13.12
.9
.001
.999 47 BBIO(96,1)
LOGNORMAL-N 3.4 1.1 48 BRTF(94,1)
TRUNCATED LOGNORMAL-N -6.91
.9
.001
.999 IRESRAD, version 6.5 T< Limit = 30 days 11/28/2011 17:38 Page 3
Probabilistic results summary : HR soil DCGL-Cm244 File : C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\CM244 DCGL\\HB SOIL DCGLCM244.RAD Probabilistic Input (cont.)
Number Name Distribution Parameters 49 BRTF(94,2)
TRUNCATED LOGNORMAL-N -9.21
.2
.001
.999 50 BRTF(94,3)
TRUNCATED LOGNORMAL-N -13.82
.5
.001
.999 51 BBIO(94,1)
LOGNORMAL-N 3.4 1.1 52 BRTF(88,1)
TRUNCATED LOGNORMAL-N -3.22
.9
.001
.999 53 BRTF(88,2)
TRUNCATED LOGNORMAL-N -6.91
.7
.001
.999 54 BRTF(88,3)
TRUNCATED LOGNORMAL-N -6.91
.5
.001
.999 55 BBIO(88,1)
LOGNORMAL-N 3.9 1.1 56 BRTF(90,1)
TRUNCATED LOGNORMAL-N -6.91
.9
.001
.999 57 BRTF(90,2)
TRUNCATED LOGNORMAL-N -9.21 1
.001
.999 58 RRTF(90,3)
TRUNCATED. LOGNORMAL-N -12.21
.9
.001
.999 59 BBIO(90,1)
LOGNORMAL-N 4.6 1.1 60 BRTF(92,1)
TRUNCATED LOGNORMAL-N -6.21
.9
.001
.999 61 RRTF(92,2)
TRUNCATED LOGNORMAL-N -7.13
.7
.001
.999 62 BRTF(92,3)
TRUNCATED LOGNORMAL-N -7.82
.6
.001
.999 63 BBIO(92,1)
LOGNORMAL-N 2.3 1.1 111111 fiffifif11itiffi111 fitffittffil1*IftiI1if fiiitiifi111i*1~iffiff*
itiiii tfifiI~i IRESRAD, Version 6.5 T-Limit = 30 days 11/28/2011 17:38 Page 21 Probabilistic results summary : HR soil DCGL_Cm244 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM244 DCGL\\HB SOIL DCGL..CM244.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1
0.OOOE+00 5.197E-01
.000016
.1365 B ARTLEETT Page 50
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 Cm-245 Results:
IRESRAD, version 6.5 T' Limit = 30 days 11/28/2011 18:32 Page 1
Summary : HB soil DCGLCm245 File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM245 DCGL\\HB SOIL DCGLCM245.RAD Table of Contents Part I: Mixture Sums and single Radionuclide Guidelines fifftiittl1filliffitf1i1tt11*il lifitfiflilffttiltif111f Dose Conversion Factor (and Related) Parameter Summary...
2 Site-Specific Parameter Summary............................
4 Summary of Pathway Selections..............................
8 Contaminated Zone and Total Dose Summary.................
9 Total Dose Components Time = O.O00E+00.....................................
10 Time = 1.000E+00....................................
11 Time = 3.00 E+00....................................
12 Time = 1.000E+01.....................................
13 Time = 3.OOOE+01.....................................
14 Time = 1.000E+02..
15 Time = 3.000E+02..
16 Time = 1.000E+03....................................
17 Dose/Source Ratios Summed Over All Pathways...............
18 Single Radionuclide Soil Guidelines.......................
18 Dose Per Nuclide Summed over All Pathways................
19 Soil Concentration Per Nuclide...........................
20 IRESRAD, Version 6.5 Toc Limit = 30 days 11/28/2011 18:32 Page 2
Summary : HB soil DCGLCm245 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM245 DCGL\\HB SOIL DCGLCM245.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: HB DCGLS Plus FGR 12 & FGR 11 0
3 3 Current 3
Base I Parameter Menu 3 Parameter.
value#
3 Case*
I Nam A-1 a DCF'S for external ground radiation, (mrem/yr)/(pCi/g)
A-1 Ac-225 (Source:
FGR 12) 6.371E-02 6.371E-02 DCF1(
1)
A-1 Am-241 (Source:
FGR 12) 4.372E-02 4.372E-02 DCF1(
2)
A-1 At-217 (Source:
FGR 12) 1.773E-03 1.773E-03 DCF1(
3)
A-1 Bi-213 (Source:
FGR 12) 7.660E-01 7.660E-01 DCF1(
4)
A-1 Cm-245 (Source:
FGR 12) 3.400E-01 a 3.400E-01 a DCF1(
5)
A-1 Fr-221 (Source:
FGR 12) 1.536E-01 1.536E-01 a DCF1(
6)
A-1 a Np-237 (Source:
FGR 12) 7.790E-02 7.790E-02 DCF1(
7)
A-i a Pa-233 (Source: FGR 12) 020E+00 1.020E+00 I DCF1(
8)
A-1 Pb-209 (Source: FGR 12) 7.734E-04 7.734E-04 a DCF1(
9)
A-I Po-213 (Source: FGR 12)
' O.0OOE+00 O.OoOE+00 a DCF1( 10)
A-I Pu-241 (Source: FGR 12) 5.904E-06 a 5.904E-06 DCFI( 11)
A-1 Ra-225 (Source:
FGR 12) 1.102E-02 1.102E-02 a DCF1( 12)
A-I Th-22g (Source:
FGR 12) 3.213E-01 a 3.213E-01 DCF1( 13)
A-i a Tl-209 (Source:
FGR 12) 1.293E+01 a 1.293E+01 DCF1( 14)
A-I u-233 (Source:
FGR 12) 1.397E-03 1.397E-03 DCF1( 15)
A-i I u-237 (Source:
FGR 12) 5.306E-01 5.306E-01 DCF1( 16)
B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Am-241 4.440E-01 4.440E-01 aCF2( 1)
B-1 Cm-245 4.550E-01 4.550E-01 DCF2(
2)
B-1 Np-237+D 5.400E-01 5.400E-01 DCF2(
4)
B-1 Pu-241 8.250E-03 8.250E-03 a DCF2(
5)
B-1 Pu-2 41+D 8254E-03 8.250E-03 DCF2(
6)
B-1 Th-229+D a 2169E+00 2.150E+00 DCF2(
7)
B-1 u-233 1.350E-01 1.350E-01 DCF2(
8)
D a1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Am-241 3.640E-03 3.640E-03 DCF3(
1)
D-1 Cm-245 3.740E-03 3.740E-03 DCF3(
2)
D-a Np-237+D 4.444E-03 4.440E-03 DCF3(
4)
D-1 Pu-241 6.840E-05 6.840E-05 DCF3(
5)
D-1 Pu-241+D 7.157E-05 6.840E-OS DCF3(
6)
D-1 Th-229+D 4.027E-03 3.530E-03 DCF3(
7)
D-1 u-233 2.890E-04 2.890E-04 DCF3(
8)
D-34 Food transfer factors:
a D-34 Am-241
, plant/soil concentration ratio, dimensionless a 1.830E-03 a 1.OOOE-03 a RTF(
1,1)
D-34 Am-241 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) a 5.OOOE-05 a 5.000E-05 I RTF(
1,2)
D-34 Am-241 milk/livestock-intake ratio, (pCi/L)/(pci/d) 2.000E-06 2.OOOE-06 RTF(
1,3) 0-34 D-34 Cm-245
, plant/soil concentration ratio, dimensionless 1.830E-03 1.OOOE-03 3 RTF(
2,1)
D-34 Cm-245 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) a 2.OOOE-05 2.OOOE-05 RTF(
2,2)
D-34 Cm-245 milk/livestock-intake ratio, (pCi/L) /(pci/d) 2.000E-06 2.000E-06 RTF(
2,3)
D-34 D-34 Np-237+D
, plant/soil concentration ratio, dimensionless 3.670E-02 2.OOOE-02 RTF(
4,1)
D-34 Np-237+D beef/livestock-intake ratio, (pci/kg)/(pCi/d) 1.000E-03 1.000E-03 RTF(
4,2)
D-34 Np-237+D milk/livestock-intake ratio, (pCi/L)/(pci/d) 5.000E-06 a 5.000E-06 RTF(
4,3) 0-34 IRESRAD, version 6.5 Ta Limit = 30 days 11/28/2011 18:32 Page 3
Summary : HB soil DCGL_Cm245 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\Cm245 DCGL\\HB SOIL DCGLCM245.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)
Dose Library: HB DCGLs Plus FGR 12 & FGR 11 0
a a Current Base Parameter aen Paaee Value#
a case*
Name 0-34 Pu-241
, plant/soil concentration ratio, dimensionless 1.830E-03 I1.O00E-03 3 RTF(
5,1)
D-34 a Pu-241 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-04 a 1.000E-04 RTF(
5,2)
D-34 Pu-241 milk/livestock-intake ratio, (pCi/L)/(pci/d) 1.OooE-06 a 1.000E-06 RTF(
5,3)
D-34 3 D-34 Pu-241+D
, plant/soil concentration ratio, dimensionless 1.830E-03 a 1.000E-03 a RTF(
6,1) 0-34 3 Pu-241+D beef/livestock-intake ratio, (pci/kg)/(pCi/d) 1.000E-04 1.000E-04 a RTF(
6,2)
D-34 a Pu-241+D milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.OOOE-06 I 1.000E-06 : RTF(
6,3)
D-34 3 a
D-34 I Th-229+D
, plant/soil concentration ratio, dimensionless 1.000E-03 a 1.000E-03 RTF(
7,1)
D-34 I Th-229+D beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.OOOE-04 1.000E-04 ' RTF(
7,2)
D-34 I Th-229+D milk/livestock-intake ratio, (pCi/L)/(pCi/d) 5.00OE-06 5.000E-06 3 RTF(
7,3)
D-34 a a
D-34 a u-233
, plant/soil concentration ratio, dimensionless a 2.500E-03 2.500E-03 a RTF(
8,1) f EBARTLETT Page 51
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 D-34 u-233
, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 3.400E-04 3.400E-04 RTF(
8,2)
D-34 U-233 milk/livestock-intake ratio, (pCi/L) /(pci/d) 6.000E-04 6.OOOE-04 RTF(
8,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Am-241
, fish 3.00OE+01 3.OOOE+01 BIOFAC(
1,1)
D-S Am-241
, crustacea and mollusks 1.000E+03 1.000E+03 BIOFAC(
1,2)
D-S D-5 cm-245
- fish 3.OOOE+01 3.OOOE+01 BIOFAC(
2,1)
D-5 cm-245
, crustacea and mollusks 1.000E+03 1.000E+03 BIOFAC(
2,2)
D-S D-5 Np-237+D
, fish 3.OOOE+01 3.000E+01 BIOFAC(
4,1)
D-5 Np-237+D crustacea and mollusks 4.000E+02 4.000E+02 BIOFAC(
4,2)
D-5 D-S Pu-241
, fish 3.000E+01 3.OOOE+01 BIOFAC(
5,1)
D-5 Pu-241
, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC(
5,2)
D-5 D-5 Pu-241+D
, fish 3.000E+01 3.OOOE+01 BIOFAC(
6,1)
D-5 Pu-241+D
, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC(
6,2)
D-5 3
D-5 Th-229+/-D
, fish 1.000E+02 1.000E+02 BIOFAC(
7,1)
D-5 3 Th-229+D
, crustacea and mollusks 5.0O0E+02 5.000E+02 BIOFAC(
7,2)
D-5 3
D-5 U-233
, fish 1.000E+01 1.0005+01 BIOFAC(
8,1)
D-S I U-233
. crustacea and mollusks 6.OOOE+01 6.000E+01 BIOFAC(
8 2)
- For OCFl(xxx) only, factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Default.Lib w/o Associate Nuclide contributions.
IRESRAD, Version 6.5 Ta Limit = 30 days 11/28/2011 18:32 Page 4
Summary : HB soil DCGL.Cm245 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM245 DCGL\\HB SOIL DCGL_CM245.RAD 0
menu3 ROll R011 ROll ROll Roll Roll R011 Roll ROll R0113 R0113 R0113 ROll R01l ROll R012 R012 R013 R013 R013 R013 R013 ROl3 R013 R013I R013 R013 R013 R013 R013 R013 R013 R014 RO14 ROl3 ROI4 R014 R014 R014 R014 R014 R014 R014 R014 Parameter Area of contaminated zone (m**2)
Thickness of contaminated zone (m)
Fraction of contamination that is submer(
Length parallel to aquifer flow (m)
Basic radiation dose limit (mrem/yr)
Time since placement of material (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Initial principal radionuclide (pCi/g):
concentration in groundwater (pCi/L):
cover depth (m)
Density of cover material (g/cm 3 *3)
Cover depth erosion rate (m/yr)
Density of contaminated zone (g/cm**3)
Contaminated zone erosion rate (m/yr)
Contaminated zone total porosity contaminated zone field capacity contaminated zone hydraulic conductivity Contaminated zone b parameter Average annual wind speed (m/sec)
Humidity in air (g/m**3)
Evapotranspiration coefficient Precipitation (m/yr)
Irrigation (m/yr)
Irrigation mode Runoff coefficient watershed area for nearby stream or pond Accuracy for water/soil computations Density of saturated zone (g/cm**3) saturated zone total porosity saturated zone effective porosity saturated zone field capacity saturated zone hydraulic conductivity (m, saturated zone hydraulic gradient saturated zone b parameter water table drop rate (m/yr) well pump intake depth (m below water tat Model: Nondispersion (ND) or Mass-Balanc well pumping rate (m**3/yr)
Site-Specific Parameter Summary User I
used by RESRAD Parameter Input Default I (If different from user input)
Na me 3.000E+04 1.O00E+04 AREA 2.670E+00 2.OOOE+00 THICKO ged O.OOOE+00 0.O00E+00 SUBMFRACT 1.950E+02 1.OOOE+02 LCZPAQ 2.500E+01 3.OOOE+01 BRDL 0.O00E+00 O.OOOE+00 TI l.OO0E+00 l.O00E+00 T( 2) 3.OOOE+00 3.OOOE+00 T( 3)
I.O00E+OI 1.000E+01 T( 4) 3.OOOE+01 3.000E+01 T( 5) 1.OOOE+02 I1.O00E+02 T( 6) 3.OOOE+02 3.000E+02 T( 7) 1.OOOE+03 1.000E+03 T(
8) not used 0.O0OE+O0 T( 9) not used 0.O0E+OO0 T(10)
Cm-245 l.OOOE+00 O.000E+00 S1(2)
Cm-245 not used O.O000E+00 wl( 2)
O.OOOE+00 O.OOOE+00 COVERO not used 1.50OE+OO DENSCV not used 1.O00E-03 VCV 1.564E+00 1.SOO+00 DENSCZ 2.200E-03 1.000E-03 VCZ 4.100E-01 4.000E-01 TPCZ 9.500E-02 2.000E~0l 3 FCCZ (m/yr) 3.900E+00 1.O00E+01 HCCZ 5.600E+00 S.300E+00 BCZ 3.040E+00 2.OOOE+00 WIND not used 8.000E+00 HUMID 6.250E-0l 5.000E-01 EVAPTR 9.100E-01 1.000E+00 PRECIP S.600E-01 2.OOOE-01 RI overhead overhead IDITCH 5.OOOE-01 2.OOE-O1 RUNOFF (m**2) 2.520E+07 1.OOOE+06 3WAREA 1.OOOE-03 1.000E-03 3 EPS 1.510E+00 1.500E+00 DENSAQ 4.300E-01 4.000E-01 TPSZ 3.420E-01 2.000E-01 EPSZ 8.800E-02 2.000E-01 FCSZ
/yr) 2.880E+01 1.000E+02 HCSZ 2.000E-03 2.000E-02 HGWT 7.100E+O0 5.300E+00 BSZ 1.O00E-03 1.000E-03 VW-ble) 1.OOOE+01 l.OOOE+O1 DWIBWT e (MB) 3 NO 3 N MODEL 1.573E+03 2.5OOE+02 Uw 1RESRAD, version 6.5 T-Limit = 30 days 11/28/2011 18:32 Page 5
Summary : HB soil DCGLCm245 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM245 DCGL\\HB SOIL DCGLCM245.RAD 0
3 menu 'Parameter ROl5 Number of unsaturated zone strata ROS 3 Unsat. zone 1, thickness (m)
ROS Unsat. zone 1, soil density (g/cm*
R015 unsat. zone 1, total porosity R015 Unsat. zone 1, effective porosity RO15 Unsat. zone 1, field capacity RO15 3 unsat. zone 1, soil-specific b par R015 unsat. zone 1, hydraulic conductiv R016 Distribution coefficients for Cm-2 R016 Contaminated zone (cm**3/g)
R016 unsaturated zone 1 (cm**3/g)
R016 saturated zone (cm**3/g)
R016 Leach rate (/yr)
R016 Solubility constant R016 Distribution coefficients for daug R016 Contaminated zone (cm*
3 3/q) f&BARTLETT Site-Specific Parameter summary (continued)
User 3
Used by RESRAD Parameter
. Input........
DeI.pu.....
e..fault.fdiffere int from user input)
Name 1
31
-NS 4.040E+00 3 4.000E+00 H(1)
"3) 1.564E+00 1.500+00 DENSUZ(1) 4.100E-01 4.000E-01 TPUZ(1) 3.150E-01 I 2.OOOE-01 EPUZ(1) 9.500E-02 I 2.OOOE-01 FCUz(1) ameter 5.600E+00 S.300E+00 BUZ(1) ity (m/yr) 3.900E+00 1.O00E+01 HCUZ(1) 4S 3
6.761E+03
-1.O000E+00 DCNUCC( 2) 6.761E+03 1-1.OOOE+00 DCNUCU( 2,1) 6.761E+03 '-1.O000E+0 DCNUCS( 2) 0.OOOE+00 O.O000E+00 1.349E-05 ALEACH( 2) 0.OOOE+O0 3 0.000E+00 not used SOLUBK( 2) hter Am-241 1.445E+03 3 2.OOOE+01 3 DCNUCC( 1)
S 1
o Page 52 Page 52
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R016 Unsaturated zone 1 (cm**3/g) 1.445E+03 a 2.OOOE+01 R016 Saturated zone (cm**3/g) 1.445E+03 2.OOOE+O1 R016 Leach rate (/yr)
O.OOOE+O0o O.O00E+O0 ROt6 Solubility constant O.OOOE+00 a0.OOOE+0O RO16 Distribution coefficients for daughter Np-237 S
R016 Contaminated zone (cm**3/g) a 1.700E+01
-t.0OOOE+O0 RO16 Unsaturated zone 1 (cm**3/g) 1.700E+01 3 -1.O00E+OO RO16 Saturated zone (cm**3/g) a 1.700E+01 3-1.0ooE+00 R016 Leach rate (/yr)
- a.
000E+0 O.OOOE+O0 R016 Solubility constant O.OOOE+O0 O.OOOE+O0 R
a16 Distribution coefficients for daughter Pu-241 a
R016 Contaminated zone (cm**3/g) a 9.530E+02 a 2.OOOE+03 a R016 Unsaturated zone 1 (cm**3/g) 9.530E+02 2.000E+03 R016 a Saturated zone (cm**3/g) 9.530E+02 2.000E+03 RO6 Leach rate (/yr)
O.OOOE+0 0.O00E+00 RO6 Solubility constant O.OOOE+00 O.OOOE+00 ROI6 Distribution coefficients for daughter Th-229 ROl6 a Contaminated zone (cm**3/g) 5.884E+03 6.OOOE+04 R016 a Unsaturated zone 1 (cm**3/g) 5.884E+03 6.oOOE+04 R016 Saturated zone (cm**3/g) 5.884E+03 6.OOE+04 RO16 a Leach rate (/yr)
O.OOOE+0O O.000E+O0 ROs6 a Solubility constant O.OOOE+O0 0.OOOE+O0 RO6 a Distribution coefficients for daughter U-233 RO6 Contaminated zone (cm**3/g) 1.260E+02 5.O00E+O1 ROt6 a Unsaturated zone 1 (cm**3/g) 1.260E+02 5.OOOE+01I R016 Saturated zone (cm**3/g) 1.260E+02 5.OOOE+01 R016 Leach rate (/yr)
O.OOOE+OO a O.o00E+O0 R016 Solubility constant a O.OOOE+O0 O.O00E+O0 a 1RESRAD, Version 6.5 T1 Limit = 30 days 11/28/2011 18:32 Page 6
Summary HB soil DCGL_Cm245 File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM245 DCGL\\HB SOIL DCGLCM245.RAD 6.309E-05 not used 5.294E-03 not used 9.565E-05 not used 1.SSOE-05 not used 7.224E-04 not used DCNUCU( 1,1)
DCNUCS(
1)
ALEACH(
1)
SOLUBK(
1)
DCNUCC( 4)
DCNUCU( 4,1)
DCNUCS( 4)
" ALEACH( 4)
SOLUBK(
4)
DCNUCC( 5) a DCNUCU( 5,1) 3 DCNUCS( 5)
ALEACH( 5)
SOLUBK( 5)
DCNUCC( 7)
DCNUCU( 7,1)
DCNUCS( 7) a ALEACH( 7)
SOLUBK( 7) 3 DCNUCC(
8) a DCNUCUC 8,1)
DCNUCS( 8)
ALEACH( 8) a SOLUBK(
8) 0 Menu 3Parameter ROlI Inhalation rate (m**3/yr)
RO17 Mass loading for inhalation (g/m**
ROl7 a Exposure duration ROl7 a Shielding factor, inhalation RO7 a Shielding factor, external gamma ROl7 Fraction of time spent indoors ROl7 a Fraction of time spent outdoors (oi R017 a Shape factor flag, external gamma R017 Radii of shape factor array (used R017 Outer annular radius (m),
ring R017 a Outer annular radius (m),
ring ROlI Outer annular radius (m),
ring R017 a Outer annular radius (m),
ring R017 Outer annular radius (m),
ring RO17 Outer annular radius (m),
ring R017 Outer annular radius (m),
ring ROll Outer annular radius (m),
ring R017 Outer annular radius (m),
ring R017 Outer annular radius (m),
ring 1i RO7I Outer annular radius (m),
ring 1 R017 Outer annular radius (m),
ring 1 R017 Fractions of annular areas within ROl7 Ring 1
ROl7 Ring 2
ROl7 Ring 3
R017 Ring 4
R017 Ring 5
ROl7 Ring 6
ROI7 Ring 7
R017 a Ring 8
ROl Ia Ring 9
R017 Ring 10 R017 Ring 11 R017 a Ring 12 R018 Fruits, vegetables and grain consui R018 Leafy vegetable consumption (kg/yr R018 a Milk consumption (L/yr)
R018 Meat and poultry consumption (kg/y R018 a Fish consumption (kg/yr)
R018 Other seafood consumption (kg/yr)
R018 Soil ingestion rate (g/yr)
R018 Drinking water intake (L/yr)
R018 Contamination fraction of drinking R018 Contamination fraction of househol R018 Contamination fraction of livestoc R018 Contamination fraction of irrigati R018 Contamination fraction of aquatic R018 Contamination fraction of plant fo IRESRAD, Version 6.5 T" Limit = 30 da Summary : HB soil DCGLCm245 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USE Site-Specific Parameter Summary (continued) a User 3
a Used by RESRAD 3
Parameter Input 3.Default (if diferent from user input) a Name 8.400E+03 8.400E+03 a
3 INHALR
- 3) a 1.OOOE-04 3 1.OoE-04 a--
MLINH I 3.000E+O1 3.OOOE+O1 a-ED a s.500E-01 3 4.0OO-O1 a-a SHF3 a 2.725SE-01 7.OOOE-01 a-3 SHF1 a 6.571E-01 S.OOOE-OI aFIND n site) a 1.181E-01 2.500E-01 FOTD 1.OO0E+OO a 1.OOOE+O0
>0 shows circular AREA.
FS if FS= -):
a a
a 1
a not used S.OOOE+O1 a-a RAD. HAPEC I) 2:
not used 7.071E+01 a RADSHAPE(
2) 3:
not used 0.000E+00 RAD.SHAPE(
3) 4:
not used 0.000E+O0 aa RADSHAPE(
4)
S" not used 30.OO0E+0 RADOSHAPE( 5) 6:
not used 0.000E+00 RADSHAPE(
6) 7" not used aO.OOOE+O RADSHAPE(
7) 8:
not used a O.00+00 a-RADSHAPE(
8) 9:
not used a O.OOOE+00 aRADSHAPE(
9) 0:
not used O.OO0E+OO RADSHAPE(10) 1:
not used a O.OO00+O0 aRADSHAPE(11) 2:
not used a O.O00E+00 ADSHAPE(12)
AREA:
not used a 1.O00E+O0 FRACA( 1) not used 2.732E-01 FRACA( 2) not used O.00E+0O a
FRACA( 3) a not used O.OOOE+O0 a FRACA( 4) not used O.OOOE+00 a-a FRACA( 5) a not used O.O00E+OO a-a FRACA( 6) a not used O.OOOE+O0 a-a FRACA( 7) a not used 0.000E+00 FRACA( 8) a not used O.OOOE+O0 FRACA( 9) not used O.OOOE+O0 FRACA(IO) not used a O.000E+00 3 FRACA(II) not used O.OOOE+O0 a-a FRACA(12) mption (kg/yr) 1.120E+02 1.600E+02 a-a DIET(l) 2.140E+01 a 1.400E+01 a DIET(2) 2.330E+02 9.200E+01 a DIET(3) r)
6.510E+01 6.300E+01 a DIET(4) 2.060E+01 5.400E+00 a-3 DIET(5) 9.OOOE-Ot 9.000E-O1 DIET(S) 1.826E+01 3.650E+01 a SOIL 4.785E+02 5.100E+02 aDW water 1.0OOE+OO 1.000E+O0 FDW d water not used 1.OOOE+O0 FHHW k water 1.0OOE+00 l.OOOE+O0 a FLW on water a.OOE+0O I.OOOE+O0 a--
FIRW food 3 l.OOOE+O0 5.000E-OI a-a FR9 od
'.OOOE+00
'-1 a FPLANT ys 11/28/2011 18:32 Page 7
RFILES\\CM245 DCGL\\HB SOIL DCGLCM24S.RAD 0
3 aen 3
Parameter R018 Contamination fraction of meat R018 a Contamination fraction of milk R019 Livestock fodder intake for meat (
R019 Livestock fodder intake for milk Ro19 Livestock water intake for meat (L R019 a Livestock water intake for milk (L R019 Livestock soil intake (kg/day)
R019 Mass loading for foliar deposition R019 Depth of soil mixing layer (m)
R019 Depth of roots Cm)
R019 Drinking water fraction from groun R019 Household water fraction from grou t
BARTLETT Site-Specific Parameter Summary (continued)
User a
a used by RESRAD 3..input a
Default a(if different from user input)
I.OOOE+00 '-1 t.OOOE+00 '-1 kg/day) a 2.710E+01 I 6.800E+01--
kg/day) 6.320E+01 3 5.500E+01 a
/day) a 5.060E+01 a 5.OOOE+O1 a
/day) 6.OOOE+01 ' 1.600E+02 5.00OE-01 a 5.000E-01 (g/m**3) 4.OOOE-04 1
1.OOOE-04 a 2.300E-01 1.500E-O1 1.220E+00
- 9.OOE-OI d water I.OOOE+O0 I.O0OE+O0 a
nd water not used 1.OOOE+O0 a Parameter Name......
FMEAT FMILK a LFI5 LFI6 SLWI 5 aLWIS6 LSI MLFD DM a DROOT a FGWDW
'EGWHH Page 53
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 R019 Livestock water fraction from ground water 1.0OOE+00 1.OOOE+00 FGWLW R019 Irrigation fraction from ground water 1.OOOE+00 1.000E+00 FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.00OE-01 a-YV(1)
R19B a Wet weightcCrop yield for Leafy (kg/m**2) 2.889E+00 1.500E+O 0
Yv(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+O0 0 Yv(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01
-- 4 TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 a TE(2)
R19B a Growing Season for Fodder (years) 8.200E-02 8.OOOE-02 a-TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.OOOE-O1 a--
TIV(1)
R19B Translocation Factor for Leafy 1.OOOE+00 1.OOOE+0O a TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.OOOE+O0 a-TIV(3)
R19B.a Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.SOOE-01 2.500E-01 RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 a 2.500E-01 RDRY(3)
RI9B Wet Foliar Interception Fraction for Non-Leafy a 3.S0OE-01 3 2.500E-01 RWET(1)
R19B Wet Foliar Interception Fraction for Leafy a 5.8OOE-01 2.SOOE-01 a~RWET(2)
RI98 Wet Foliar Interception Fraction for Fodder 3.500E-01 a 2.5OOE-01 a
RWET(3)
Re9B a Weathering Removal Constant for Vegetation a 3.300E+01 a 2.oOOE+Ol a-a WLAM C14 C-12 concentration in water (g/cm**3) a not used a 2.000E-05 a-a C12WTR C14 C-12 concentration in contaminated soil (g/g) a not used 3 3.00OE-02 a-a cl2cz C14 Fraction of vegetation carbon from soil not used a 2.000E-02 CSOIL C14 a Fraction of vegetation carbon from air a not used 9.800E-01 CAIR C14 C-14 evasion layer thickness in soil (m) a not used a 3.000E-01 DMC C14 C-14 evasion flux rate from soil (1/sec) a not used a 7.000E-07 EVSN C14 a C-12 evasion flux rate from soil (1/sec) a not used 1.000E-10 REVSN C14 a Fraction of grain in beef cattle feed not used 8.000E-01 a-a AVFG4 C14 Fraction of grain in milk cow feed not used 2.0OOE-01 a AVFGS STOR a Storage times of contaminated foodstuffs (days):
STOR a Fruits, non-leafy vegetables, and grain 1.400E+01 a 1.400E+01 a aSTOR (1)
STOR Leafy vegetables 0 3 1E+E+0a 0
3 STOR_-(2)
STOR a Milk 1.000E+O0 a 1.O00E+00 STORT(3)
STOR a Meat and poultry a 2.000E+01 2.OOOE+01 STORT(4)
STOR a Fish a 7.O00E+00 a 7.000E+00 STORT(S)
STOR Crustacea and mollusks a 7.000E+00 a 7.000E+00 STORT(6)
IRESRAD, Version 6.5 T'c Limit = 30 days 11/28/2011 18:32 Page 8
Summary : HB soil DCGL-Cm245 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM245 DCGL\\HB SOIL DCGLCM245.RAD Site-Specific Parameter Summary (continued) 0 3
a user a
used by RESRAD a
Parameter Menu 3
Parameter a
Iu......
pt 3.efault a(if different from user input) 3 Name...
STOR a Well water 3.00E+00 1.000E+00 a STORT(7)
STOR a Surface water 1.oooE+00 1.0006E+0 a
a STORT(8)
STOB 3 Livestock fodder 4.500E+01 4.500E+01 a STOPLT(9)
R021 Thickness of building foundation (m) not used a 1.500E-01 FLOORI R021 Bulk density of building foundation (g/cm**3) not used 3 2.400E+00 a DENSFL R021 Total porosity of the cover material not used 4.000E-01 TPCV R021 Total porosity of the building foundation not used 1.000E-01 TPFL R021 a Volumetric water content of the cover material not used a 5.000E-02 a a PH2oCv R021 volumetric water content of the foundation not used 3.000E-02 a PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 3 in cover material not used a 2.000E-06 DIFCV R021 in foundation material not used a 3.000E-07 a DIFFL R021 in contaminated zone soil not used a 2.000E-06 a-DIFCZ R021 Radon vertical dimension of mixing (m) not used a 2.000E+00 a--
HMIX R021 Average building air exchange rate (1/hr) a not used a 5.OOOE-01 a3a REXG R021 Height of the building (room)
(m) a not used a 2.500E+00 3 HRM R021 a Building interior area factor a not used a 0.OOOE+00 FAI R021 Building depth below ground surface (m) not used 3-1. 0 OOF+
0 0
3 DMFL R021 Emanating power of Rn-222 gas a not used a 2.500E-01 EMANA(1)
R021 a Emanating power of Rn-220 gas not used a 1.500E-01 a-- EMANA(2)
TITL Number of graphical time points 32 a
NPTS TITL a Maximum number of integration points for dose a
17 a
LYMAX TITL Maximum number of integration points for risk a
i KYNAX Summary of Pathway Selections
.Pathwyy User Selection A...
XX.XX X XX X X X XX X
1-- external gamma active 2
inhalation (w/o radon)a active 3--
plant ingestion a
active 4
meat ingestion active 5
milk ingestion a
active 6
aquatic foods a
active 7
drinking water active 8
soil ingestion a
active 9 --
radon a
suppressed Find peak pathway doses a
active IRESRAD, Version 6.5 T' Limit = 30 days 11/28/2011 18:32 Page 9
Summary : HB soil OCGL_Cm245 File
- C:\\RESR.ADFAMILY\\RESRAD\\6.5\\USERFILES\\cM245 DCGL\\HB SOIL DCGLCM245.RAD Contaminated Zone Dimensions Initial Soil Concentrations-, i/
z I....
- .m *................
i.
XXXXXXXXXXXXXXXXXXXXX AXAAXXAXAXXAAAAXAAAAAAAa Area:
30000.00 square meters Cm-245 1.OOOE+00 Thickness:
2.67 meters Cover Depth:
0.00 meters 1RESRAD, Version 6.5 To Limit = 30 days 11/28/2011 18:32 Page 1
Probabilistic results summary : HB soil DCGL-Cm245 File : C:\\RESRADOFAMILY\\RESRAD\\6.5\\USERFILES\\CM245 DCGL\\HB SOIL DCGLCM245.RAD Table of Contents Part VI: Uncertainty Analysis Ift~t~tttilffifffi*ilfffill ORESRAD Uncertainty Analysis Results Probabilistic Input..
2 Total Dose...
4 tBA RTLE'TT Page 54
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Total Risk...
5 Dose vs Pathway:
Ground External...................
6 Dose vs Pathway:
Inhalation (w/o Radon).............
7 Dose vs Pathway:
Radon (Water Ind.).................
8 Dose vs Pathway:
Plant (Water Ind.).................
9 Dose vs Pathway:
Meat (water Ind.)................
10 Dose vs Pathway:
Milk (Water Ind.).................
11 Dose vs Pathway:
Soil Ingestion....................
12 Dose vs Pathway:
Water Ingestion...................
13 Dose vs Pathway:
Fish Ingestion...................
14 Dose vs Pathway:
Radon (Water Dep.)
15 Dose vs Pathway:
Plant (Water Dep.).................
16 Dose vs Pathway:
Meat (Water Dep.).................
17 Dose vs Pathway:
Milk (Water Dep.)
18 Cumulative Probability Summary.......................
19 Summary of dose at graphical times, reptition I.....
20 Peak of the mean dose at graphical times.............
21 Correlation and Regression coefficients (if any).....
22 1RESRAD, Version 6.5
'T Limit = 30 days 11/28/2011 18:32 Page 2
Probabilistic results summary : HB soil DCGLCm245 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM245 DCGL\\HB SOIL DCGLCM245.RAD Probabilistic Input ONumber of Sample Runs: 2000 Number Name Distribution Parameters 1
DENSCZ ROUNDED NORMAL 1.5635
.2385
.827 2.3 2
TPCZ BOUNDED NORMAL
.41
.09
.1319
.6881 3
HCCZ BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 4
BCZ BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 5
EVAPTR UNIFORM
.5
.75 6
RI UNIFORM
.36
.76 7
DENSAQ BOUNDED NORMAL 1.5105
.1855
.937 2.084 8
TPSZ BOUNDED NORMAL
.43
.0699
.214
.646 9
EPSZ BOUNDED NORMAL
.342
.0705
.124
.56 10 HCSZ BOUNDED LOGNORMAL-N.362 1.59
.0106 195 11 BSZ BOUNDED LOGNORMAL-N 1.96
.265 3.02 15.5 12 DWIBWT TRIANGULAR 6
10 30 13 UW UNIFORM 1173 1973 14 H(1)
UNIFORM 0
8.08 15 DENSUZ(1)
BOUNDED NORMAL 1.5635
.2385
.827 2.3 16 TPUZ(1)
BOUNDED NORMAL
.41
.09
.1319
.6881 17 EPUZ(1)
BOUNDED NORMAL
.315
.0905
.0349
.594 18 HCUZ(1)
BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 19 BUZ(1)
BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 20 MLINH CONTINUOUS LINEAR 8
0 0
.000008
.0151
.000016
.1365
.00003
.8119
.00004
.9495
.00006
.9937
.000076
.9983
.0001 1
21 SHF3 UNIFORM
.15
.95 22 SHF1 BOUNDED LOGNORMAL-N -1.3
.59
.044 1
23 DM TRIANGULAR 0
.15
.6 24 YV(1)
TRUNCATED LOGNORMAL-N.56
.48
.001
.999 25 WLAM TRIANGULAR 5.1 18 84 26 RWET(2)
TRIANGULAR
.06
.67
.95 27 OCACTC(2)
TRUNCATED LOGNORMAL-N 8.82 1.82
.001
.999 28 DCACTUI(2)
TRUNCATED LOGNORMAL-N 8.82 1.82
.001
.999 29 DCACTS(2)
TRUNCATED LOGNORMAL-N 8.82 1.82
.001
.999 30 DCACTC(1)
TRUNCATED LOGNORMAL-N 7.28 3.15
.001
.999 31 OCACTU1(1)
TRUNCATED LOGNORMAL-N 7.28 3.15
.001
.999 32 DCACTS(1)
TRUNCATED LOGNORMAL-N 7.28 3.15
.001
.999 33 DCACTC(4)
TRUNCATED LOGNORMAL-N 2.84 2.25
.001
.999 34 DCACTU1(4)
TRUNCATED LOGNORMAL-N 2.84 2.25
.001
.999 35 DCACTS(4)
TRUNCATED LOGNORMAL-N 2.84 2.25
.001
.999 36 DCACTC(5)
TRUNCATED LOGNORMAL-N 6.68 1.89
.001
.999 37 OCACTUl(5)
TRUNCATED LOGNORMAL-N 6.86 1.89
.001
.999 38 DCACTS(S)
TRUNCATED LOGNORMAL-N 6.86 1.89
.001
.999 39 DCACTC(7)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001
.999 40 DCACTU1(7)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001
.999 41 DCACTS(7)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001
.999 42 DCACTC(8)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001
.999 43 oCACTUI(8)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001
.999 44 DCACTS(8)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001
.999 45 BRTF(96,2)
TRUNCATED LOGNORMAL-N -10.82 1
.001
.999 46 BRTF(96,3)
TRUNCATED LOGNORMAL-N -13.12
.9
.001
.999 47 BBIO(96,1)
LOGNORMAL-N 3.4 1.1 48 BRTF(95,1)
TRUNCATED LOGNORMAL-N -6.91
.9
.001
.999 IRESRAD, Version 6.5 To Limit = 30 days 11/28/2011 18:32 Page 3.
Probabilistic results summary : HB soil DCGLCm245 File : C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\CM245 DCGL\\HB SOIL DCGLCM245.RAD Probabilistic Input (cont.)
Number Name Distribution Parameters 49 BRTF(95,2)
TRUNCATED LOGNORMAL-N -9.9
.2
.001
.999 so BRTF(95,3)
TRUNCATED LOGNORMAL-N -13.12
.7
.001
.999 51 BBIO(95,1)
LOGNORMAL-N 3.4 1.1 52 BRTF(93,1)
TRUNCATED LOGNORMAL-N
-3.91
.9
.001
.999 53 BRTF(93,2)
TRUNCATED LOGNORMAL-N -6.91
.7
.001
.999 54 BRTF(93,3)
TRUNCATED LOGNORMAL-N -11.51
.7
.001
.999 55 BBIO(93,1)
LOGNORMAL-N 3.4 1.1 56 BRTF(94,1)
TRUNCATED LOGNORMAL-N -6.91
.9
.001
.999 57 BRTF(94,2)
TRUNCATED LOGNORMAL-N -9.21
.2
.001
.999 58 BRTF(94,3)
TRUNCATED LOGNORMAL-N -13.82
.5
.001
.999 59 BBIO(94,1)
LOGNORMAL-N 3.4 1.1 60 BRTF(90,1)
TRUNCATED LOGNORMAL-N
-6.91
.9
.001
.999 61 BRTF(90,2)
TRUNCATED LOGNORMAL-N -9.21 1
.001
.999 62 BRTF(90,3)
TRUNCATED LOGNORMAL-N -12.21
.9
.001
.999 63 BBIO(90,1)
LOGNORMAL-N 4.6 1.1 64 BRBF(92,1)
TRUNCATED LOGNORMAL-N -6.21
.9
.001
.999 65 BRTF(92,2)
TRUNCATED LOGNORMAL-N -7.13
.7
.001
.999 66 BRTF(92,3)
TRUNCATED LOGNORMAL-N -7.82
.6
.001
.999 67 BBio(92.1)
LOGNORMAL-N 2.3 10 9
11t67 BBiO2 1
)
LtGNtRiAtiitL-23tti.i1fittI*tft*ItI*
Ittttitttfiittiit IRESRAD, Version 6.5 Tm Limit = 30 days 11/28/2011 18:32 Page 21 Probabilistic results summary : HB soil DCGLcm245 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM245 DCGL\\HB SOIL DCGL.CM245.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose (MBARTLETT Page 55
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 1
Years S. 878E+02 mrem/yr 1.406E+00 tBA RTLETT Page 56
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 Cm-246 Results:
IRESRAD, Version 6.5 To Limit = 30 days 11/28/2011 13:35 Page 1
Summary : HB soil DCGL_Cm246 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM246 DCGL\\HB SOIL DCGL_CM246.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines fi1if% iffifffit1f1ffffIIi1fff fffffff Ilffff1fffiI1*1f Dose Conversion Factor (and Related) Parameter Summary...
2 Site-Specific Parameter Summary..........................
5 Summary of Pathway Selections............................
10 Contaminated Zone and Total Dose Summary..................
11 Total Dose Components Time = O.00OE+00.....................................
12 Time = 1.OOOE+O0....................................
13 Time = 3.000E+00....................................
14 Time = 1.0OO0E+O1......................................
15 Time = 3.OOOE+01.....................................
16 Time = 1.OOOE+02..
17 Time = 3.OOOE+02..
18 Time = 1.000E+03....................................
19 Dose/Source Ratios Summed Over All Pathways..............
20 Single Radionuclide Soil Guidelines.......................
20 Dose Per Nuclide Summed over All Pathways.................
21 Soil Concentration Per Nuclide...........................
22 iRESRAD, Version 6.5 T' Limit = 30 days 11/28/2011 13:35 Page 2
Summary : HB soil DCGL_Cm246 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM246 DCGL\\HB SOIL DCGLCM246.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: HB DCGLS Plus FGR 12 & FGR 11 0
3 Current 3
Base 3
Parameter Menu P
Iame a
Value#
C aset 3
Name A-i DCF's for external ground radiation, (mrem/yr)/(pCi/g)
A-1 a At-218 (Source:
FGR 12) 5.847E-03 5.847E-03 DCF1(
1)
A-1 a Bi-210 (Source:
FGR 12) a 3.606E-03 a 3.606E-03 a DCF1(
2)
A-1 8i-214 (Source:
FGR 12) 9.808E+00 9.808E+00 3 DCF1(
3)
A-1 a Cm-246 (Source:
FGR 12) a 1.162E-04 a 1.162E DCFI(
4)
A-1 a Pa-234 (Source:
FGR 12) a 1.155E+01 1.155E+01 DCF1(
5)
A-i a Pa-234m (Source:
FGR 12) a 8.967E-02 8.967E-02 DCF1(
6)
A-1 Pb-210 (Source:
FGR 12) a 2.447E-03 2.447E-03 a DCF1(
7)
A-1 a Pb-214 (Source:
FOR 12) a 1.341E+00 1.341E+00 a DCF1(
8)
A-1 a Po-210 (Source:
FGR 12) a 5.231E-05 5.231E-05 a DCFI(
9)
A-1 a Po-214 (Source:
FGR 12) 1 5.138E-04 5.138E-04 a DCFI( 10)
A-1I Po-218 (Source:
FGR 12) 5.642E-05 5.642E-05 a DCF1( 11)
A-1I Pu-242 (Source:
FGR 12) 1.280E-04 1.280E-04 a DCF1( 12)
A-i a Ra-226 (Source: FGR 12) 3.176E-02 a 3.176E-02 a DCF1( 13)
A-1 a Rn-222 (Source:
FGR 12) 2.354E-03 2.354E-03 a DCF1( 14)
A-I a Th-230 (Source: FGR 12) 1.209E-03 I1.209E-03 a DCF1( 15)
A-1 a Th-234 (Source: FGR 12) 2.410E-02 a 2.410E-02 a DCFi( 16)
A-1 a Tl-210 (Source: no data) 0.00E+00 '-2.OOOE+00 a DCF1( 17)
A-1 a U-234 (Source: FGR 12) a 4.017E-04 a 4.017E-04 a DCF1( 18)
A-1 a u-238 (Source:
FGR 12) 1.031E-04 1.031E-04 DCF1( 19)
B-1 Dose conversion factors for inhalation, mrem/pCi:
a B-I Cm-246 4.510E-01 4.510E-01 DCF2(
1)
B-1 Pb-210+D 1.380E-02 a 1.360E-02 a DCF2(
5)
B-1 a Po-210 9.400E-03 a 9.400E-03 a DCF2(
6)
B-1 a Pu-242 4.110E-01 4.110E-01 DCF2(
7)
B-1 a Ra-226+D 8.594E-03 8.580E-03 DCF2( 10)
B-1I Th-230 3.260E-01 a 3.260E-01 a DCF2(
11)
B-1 a u-234 1.320E-01 1.320E-01 a DCF2(
12)
B-1 a u-238 1.i8OE-01 1.180E-01 DCF2(
13)
B-1 a U-238+D 1.180E-01 1.180E-01 DCF2(
14)
D-1 Dose conversion factors for ingestion, mrem/pCi:
a D-1 Cm-246 3.700E-03 3.700E-03 DCF3(
1)
D-1 Pb-210+D a 5.376E-03 a 5.370E-03 a DCF3(
5)
D-1 Po-210 1.900E-03 a 1.900E-03 a DCF3(
6)
D-1 Pu-242 3.360E-03 3.360E-03 a DCF3(
7)
D-1 Ra-226+D a
321E-03 1320E-03 DCF3(
10)
D-a Th-230 5.480E-04 5.480E-04 a DCF3(
11)
D-1 U-234 a 2.830E-04 a 2.830E-04 DCF3(
12)
D-I u-238 2.550E-04 2.550E-04 DCF3(
13)
D-1 I u-238+D 2.687E-04 2.550E-04 DCF3(
14)
D-34 Food transfer factors:
D-34 Cm-246
, plant/soil concentration ratio, dimensionless a 1.830E-03 1.OOOE-03 RTF(
1,j)
D-34 Cm-246 beef/livestock-intake ratio, (pCi/kg)/(pci/d) 2.000E-05 a 2.0008-0S a RTF(
1,2)
D-34 Cm-246 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.OOOE-06 a 2.000E-06 RTF(
1,3) 0-34 a 1RESRAD, Version 6.5 To Limit = 30 days 11/28/2011 13:35 Page 3
Summary : HB soil DCGL_Cm246 File
- C:\\RESRADrFAMILY\\RESRAD\\6.5\\USERFILES\\CM246 DCGL\\HB SOIL DCGLCM246.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)
Dose Library: HB DCGLs Plus FGR 12 & FGR 11 0
Current a
Base Parameter Menu a Parameter a
value#
a Case*
a Name D-34 a Pb-210+D
, plant/soil concentration ratio, dimensionless 1.000-E02 I 1.OOOE-02 a RTF(
5,1)
D-34 a Pb-210+D beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 8.000E-04 a 8.OOOE-04.
RTF(
5,2)
D-34 Pb-210+D milk/livestock-intake ratio, (pCi/L) /(pCi/d) 3.000E-04 a 3.000E-04 a RTF(
5,3)
D-34 a a
D-34 Po-210
, plant/soil concentration ratio, dimensionless 1.OOOE-03 a 1.000E-03 3 RTF(
6,1) o-34 a Po-210 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.000E-03 a 5.000E-03 a RTF(
6,2)
D-34 a Po-210 milk/livestock-intake ratio, (pCi/L)/(pci/d) 3.400E-04 3.400E-04 a RTF(
6,3)
D-34 a D-34 I Pu-242
, plant/soil concentration ratio, dimensionless 1.830E-03 a 1.0OOE-03 3 RTF(
7,1)
D-34 a Pu-242 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-04 a 1.000E-04 a RTF(
7,2)
D-34 Pu-242 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.000E-06 a 1.000E-06 a RTF(
7,3)
D-34 a D-34 a Ra-226+D
, olant/soil concentration ratio, dimensionless a 4.000E-02 a 4.OOOE-02 3 RTF( 10,1)
D-34 Ra-226+D beef/livestock-intake ratio, (pCi/kg)/(pci/d) a 1.000E-03 a 1.OOOE-03 a RTF( 10,2) tDART LETT Page 57
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 D-34 Ra-226+D
, milk/livestock-intake ratio, (pCi/L)/(pci/d) 1.OOOE-03 1.OOOE-03 RTF(
10,3)
D-34 3
D-34 Th-230
, plant/soil concentration ratio, dimensionless 1.000E-03 1.OOOE-03 RTF( 11,I)
D-34 Th-230 beef/livestock-intake ratio, (pci/kg)/(pCi/d) 1.000E-04 1.000E-04 RTF( 11,2)
D-34 Th-230 milk/livestock-intake ratio, (pCi/L)/(pci/d) 5.OOOE-06 5.000E-06 RTF( 11,3)
D-34 D-34 u-234 Elant/soil concentration ratio, dimensionless 2.500E-03 2.500E-03 3 RTF( 12,1)
D-34 u-234 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 3.400E-04 3.400E-04 3 RTF( 12,2)
D-34 u-234 milk/livestock-intake ratio, (pCi/L)/(pci/d) 6.000E-04 6.000E-04 : RTF( 12,3)
D-34 3 D-34 u-238 plant/soil concentration ratio, dimensionless 2.50OE-03 2.500E-03 3 RTF( 13,1)
D-34 u-238 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 3.400E-04 3.400E-04 RTF( 13,2)
D-34 u-238 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 6.O00E-04 6.000E-04 RTF( 13,3)
D-343 D-34 u-238+D
, plant/soil concentration ratio, dimensionless 2.500E-03 2.500E-03 RTF( 14,1)
D-34 u-238+D beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 3.400E-04 3.400E-04 RTF( 14,2)
D-34 u-238+D milk/livestock-intake ratio, (pCi/L)/(pci/d) 6.000E-04 6.OOOE-04 RTF(
14,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Cm-246
, fish 3.000E+01 3.000E+01 BIOFAC(
1,1)
D-5 Cm-246
, crustacea and mollusks 1.000E+03 1.OOOE+03 BIOFAC(
1,2)
D-5 D-5 Pb-210+D
, fish 3.OOOE+02 3.OOE+02 BIOFAC(
5,1)
D-5 Pb-210+D
, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC(
5,2)
D-5 D-5 Po-210
, fish 1.000E+02 1.QOOE+02 BIOFAC(
6,1)
D-5 Po-210
, crustacea and mollusks 2.000E+04 2.OOOE+04 BIOFAC(
6,2)
D-5 3
D-5 Pu-242
, fish 3.000E+01 3.OOOE+01 3 BIOFAC(
7,1)
D-5 Pu-242
, crustacea and mollusks 1.000E+02 1.00OE+02 BIOFAC(
7,2)
D-5 D-5 Ra-226+D
, fish 5.000E+O1 5.000E+01 BIOFAC( 10,1)
D-5 Ra-226+D
, crustacea and mollusks 2.500E+02 2.500E+02 BIOFAC( 10,2)
D-5 D-5 Th-230
, fish 1.O00E+02 1.000E+02 BIOFAC( 11,1)
D-5 Th-230
, crustacea and mollusks 5.000E+02 5.OOOE+02 3 BIOFAC( 11,2)
- 1RESRAD, version 6.5 T,, Limit = 30 days 11/28/2011 13:35 Page 4
Summary : HB soil DCGLCm246 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\cM246 DCGL\\HB SOIL DCGLCM246.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)
Dose Library: HR DCGLs Plus FGR 12 & FGR 11 0
3 Current 3
Base Parameter Menu P
aramýeter
- l.
vaue#
3 Case*
Name D-5 I u-234
, fish 1.OOOE+01 1.O00E+0l 3 BIOFAC( 12,1)
D-5 u
u-234
, crustacea and mollusks 6.000E+01 6.000E+01 R
BIOFAC( 12,2)
D-5 D-5 3 u-238
, fish 1.000E+01 1.000E+01 3 BIOFAC( 13,1)
D-5 u-238
, crustacea and mollusks 6.OOOE+01 6.0000E+1 R
BIOFAC( 13,2)
D-5 D-5 u-238+D
, fish 1.000E+01 1.OOOE+01 3 BIOFAC( 14,1) o-5 u-238+Do
.crustacea and mollusks 6.000E+01 I 6.OOOE+01 ' BIOFAC( 14 2)
- For DCFl(xxx) only, factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Default.Lib w/o Associate Nuclide contributions.
IRESRAD, version 6.5 T'. Limit = 30 days 11/28/2011 13:35 Page 5
Summary : HB soil DCGLCm246 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\cM246 DCGL\\HB SOIL DCGLCM246.RAD Site-Specific Parameter Summary 0
3 User 3
Used by RESRAD 3 Parameter Menu Parameter 3.Input I. Default 3.(if different from user input) 3 Name R011 Area of contaminated zone (m**2)
R011 Thickness of contaminated zone (m)
R011 Fraction of contamination that is submerged R011 Length parallel to aquifer flow (m)
R011 Basic radiation dose limit (mrem/yr)
R011 Time since placement of material (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
RO11 Times for calculations (yr)
R012 initial principal radionuclide (pCi/g):
Cm-246 R012 concentration in groundwater (pCi/L):
cm-246 R013 cover depth (m)
R013 Density of cover material (g/cm t*3)
R013 Cover depth erosion rate (m/yr)
R013 Density of contaminated zone (g/cm**3)
R013 Contaminated zone erosion rate (m/yr)
R013 Contaminated zone total porosity R013 contaminated zone field capacity R013 Contaminated zone hydraulic conductivity (m/yr)
R013 Contaminated zone b parameter R013 Average annual wind speed (m/sec)
R013 Humidity in air (g/m**3)
R013 Evapotranspiration coefficient R013 Precipitation (m/yr)
R013 Irrigation (m/yr)
R013 Irrigation mode R013 Runotf coefficient R013 Watershed area for nearby stream or pond (m**2)
R013 Accuracy for water/soil computations R014 Density of saturated zone (g/cm**3)
R014 Saturated zone total porosity R014 Saturated zone effective porosity R014 Saturated zone field capacity R014 Saturated zone hydraulic conductivity (m/yr)
R014 Saturated zone hydraulic gradient R014 Saturated zone b parameter R014 Water table drop rate (m/yr)
R014 3 well pump intake depth (m below water table) t BARTLETT 3.OOOE+04 1.000E+04 2.670E+00 2.OOOE+00 0.000E+00 O.OOOE+0O 1.950E+02 1.OOOE+02 2.500E+01 3.00OE+01 0.000E+00 0.OooE+00 1.000E+00 1.000E+00 3.000E+00 3.0000E+0 1.000E+01 1.000E+01 3 3.000E+01 3.OOOE+01 1.000E+02 1.000E+02 3.000E+02 3.000E+02 1.O00E+03 1.000E+03 not used 0.0000E+0 not used 0.O00E+O00 1.O000600 0.0OOE+00 not used 0.006E+00 0.000E+00 0.000E+00 not used 1.500E+00 not used 130ooE-03 1.564E+00 1.500E+00 2.200E-03 1.000E-03 4.100E-01 4.000E-01 9.500E-02 2.000E-01 3.900E+00 1.000E+01 5.600E+00 5.300E+00 3.040E+00 2.OOOE+00 not used 8.OOOE++/-0 6.250E-01 5.000E-01 9.100E-01 31.000E+O 5.600E-01 2.OOOE-01 overhead overhead 5.00OE-01 2.000E-01 2.520E+07 1.000E+06 1.000E-03 1.000E-03
- 1.510E+00 1.500E+00 4.300E-01 4.OOOE-01 3 3.420E-01 2.000E-01 8.800E-02 2.000E-01 2.880E+01 1.000E+02 2.000E-03 2.000E-02 7.100E+00 5.300E+00 1.000E-03 1.000E-03 3.000E+01 1.000E301 AREA THICKO SUBMFRACT LCZPAQ BRDL TI T(
2)
T( 3)
T( 4)
T( 5)
T( 6)
T(
7)
T(
8)
T( 9)
T(10) 3 S1(1) 3 Wl( 1)
COVERO DENSCV vCV DENSCZ VCZ TPCZ 3FCCZ IHCCZ 3 BCZ WIND HUMID EVAPTR PRECIP RI IDITCH RUNOFF WAREA EPS DENSAQ TPSZ EPSZ
' FCSZ HCSZ 3 HGWT BSZ vWT DwIB~gT Page 58
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R014
- Model: Nondispersion (ND) or Mass-Balance (MB)
NO
' NO 3
MODEL R014 well pumping rate (m**3/yr) 1.573E+03 ' 2.500E+02 UW 1RESRAD, Version 6.5 Ta Limit = 30 days 11/28/2011 13:35 Page 6
Summary
- HB soil DCGL.Cm246 File
- C:\\RESRAD.FAMILY\\RESRAD\\6.5\\USERFILES\\CM246 DCGL\\HB SOIL DCGL-CM246.RAD Site-Specific Parameter Summary (continued)
O a
User 3
Menu a Parameter Input
- 2. Default (If R015 Number of unsaturated zone strata 1
a R015 Unsat.
zone 1, thickness (m) 4.040E+00 a 4.000E+O0 R015 a Unsat. zone 1, soil density (g/cm**3) a 1.564E+00 a 1.500E+O0 R015 a unsat. zone 1, total porosity a 4.100E-01 a 4.000E-01 R015 a unsat. zone 1, effective porosity a 3.150E-01 a 2.000E-O1 R015 a unsat. zone 1, field capacity a 9.500E-02 2.000-E-1 RO15 a Unsat. zone 1, soil-specific b parameter a 5.600E+00 a 5.300E+00 a R015 Unsat. zone 1, hydraulic conductivity (m/yr) 3.900E+00 a 1.000E+01 a R016 Distribution coefficients for Cm-246 R016 Contaminated zone (cm**3/g) a 6.761E+03 a-I.0O0E+00 a R016 a Unsaturated zone 1 (cm**31g) a 6.761E+03 3_1.00OE+00 a R016 a Saturated zone (cm**3/g) a 6.761E+03 a-1.OOOE+0a R016 a Leach rate (/yr) 0.OOOE+0 0.000E+00 R016 a Solubility constant O.OOOE+00 a O.OOOE+0O R016 Distribution coefficients for daughter Pb-210 R016 Contaminated zone (cm**3/g) 2.392E+03 1.OOOE+02 R016 Unsaturated zone 1 (cm**3/g) 2.392E+03 1.OOOE+02 R016 a Saturated zone (cm**3/g) a 2.392E+03 a 1.000E+02 a
R016 a Leach rate (/yr)
O.O000E+00 O.OOOE+0a R016 a Solubility constant O.O000E+00 O.000E+00 R016 Distribution coefficients for daughter Po-210 a
R016 Contaminated zone (cm**3/g) 1.810E+02 a 1.OOOE+01 R016 a unsaturated zone 1 (cm**3/g) 1.810E+02 a 1.000E+01 R016 a Saturated zone (cm.*3/g)
.1.810E+02 a 1.000E+01 R016 a Leach rate (/yr) 0.000E+00 a 0.000E+0O R016 a Solubility constant a.0008E+O0 0.OOOE+0O R016 a Distribution coefficients for daughter Pu-24 2
R016 a Contaminated zone (cm**3/g) a 9.530E+02 2.oO0E+03 R016 a Unsaturated zone 1 (cm**3/g) 9.530E+02 a 2.OOOE+03 R016 a Saturated zone (cm**3/g) a 9.530E+02 a 2.OooE+03 R016 a Leach rate (/yr) a OO.00E+00 a0.OOE+0O R016 a Solubility constant a O.O00E+O0 OaOOOE+O0 R016 a Distribution coefficients for daughter Ra-226 a
R016 a Contaminated zone (cm**3/g) a 3.533E+03 a 7.000E+01 R016 a unsaturated zone 1 (cm**3/g) a 3.533E+03 a 7.000E+01 a R016 a Saturated zone (cm**3/g) a 3.533E+03 a 7.000E+01 R016 a Leach rate (/yr) a.OOOE+O0 a O.00+00 R016 Solubility constant O.OOOE+00 O.OO, +O0a R016 a Distribution coefficients for daughter Th-230 a
R016 Contaminated zone (cm**3/g) a 5.884E+03 a 6.000E+04 R016 Unsaturated zone 1 (cm**3/g).
5.884E+03 a 6.000E+04 R016 a Saturated zone (cm**3/g) a 5.884E+03 a 6.00OE+04 a R016 a Leach rate (/yr)
O.O00E+00 O.0OOE+00 a R016 a Solubility constant a 0.OOOE+00 0.OO0E+00 a IRESRAD, version 6.5 Ta Limit = 30 days 11/28/2011 13:35 Page 7
Summary HB soil DCGLCm246 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM246 DCGL\\HB SOIL DCGLCM246.RAD Site-Specific Parameter Summary (continued) 0 a
a User a
a menu Parameter a
anput..
Default 3 (If used by RESRAD a
Parameter different from user input) '
Name 1.349E-05 not used 3.811E-05 not used 5.031E-04 not used 9.56SE-05 not used 2.581E-05 not used 1.55OE-05 not used NS H (1) a DENSUZ(1)
TPUZ(1)
EPUZ(1)
FCuZ(1)
BUZ(1) a HCUZ(1) a DCNUCC( 1)
DCNuCu( 1,1)
DCNUCS( 1)
ALEACH( 1)
SOLUBK( 1)
DCNUCC( 5)
DCNUCU( 5,1)
DCNUCS( 5)
ALEACH( 5)
SOLUBK( 5)
DCNUCC( 6)
DCNUCU( 6,1)
DCNUCS( 6)
ALEACH( 6)
SOLUBK( 6) a DCNUCC( 7) a DCNuCu(
7,1) a DCNUCS( 7)
ALEACH( 7)
SOLUBK( 7)
DCNUCC(1O) a DCNUCU(1O,1)
DCNUCS(1O) a ALEACH(10) a SOLUBK(10) a DCNUCC(11) a DCNUCU(11,1) a DCNUCS(11) a ALEACH(11) a SOLUBK(11) used by RESRAD a Parameter R016 Distribution coefficients for daughter U-234 R016 Contaminated zone (cma*3/g)
R016 unsaturated zone 1 (cm**3/g)
R016 Saturated zone (cm**3/g)
R016 Leach rate (/yr)
R016 a Solubility constant R016 a Distribution coefficients for daughter U-238 R016 a Contaminated zone (cm**3/g)
R016 a Unsaturated zone 1 (cm**3/g)
R016 a Saturated zone (cm**3/g)
R016 I Leach rate (/yr)
R016 Solubility constant R017 Inhalation rate (m**3/yr)
R017 Mass loading for inhalation (g/m**3)
R017 a Exposure duration R017 a Shielding factor, inhalation R017 a Shielding factor, external gamma R017 Fraction of time spent indoors R017 Fraction of time spent outdoors (on site)
R017 a Shape factor flag, external gamma R017 Radii of shape factor array (used if ES
-1):
R017 Outer annular radius (m),
ring 1:
R017 Outer annular radius (m),
ring 2:
R017 Outer annular radius (m),
ring 3:
R017 Outer annular radius (m),
ring 4:
R017 a Outer annular radius (m),
ring 5:
R017 a Outer annular radius (m),
ring 6:
R017 a Outer annular radius (m),
ring 7:
R017 a Outer annular radius (m),
ring 8:
R017 a Outer annular radius (m),
ring 9:
R017 a Outer annular radius Wm), ring 10:
R017 a Outer annular radius (m),
ring 11:
R017 Outer annular radius (m),
ring 12:
R017 Fractions of annular areas within AREA:
R017 Ring 1
R017 Ring 2
R017 Ring 3
R017 Ring 4
R017 Ring t
EBARTLETT 1.260E+02
- 1. 260E+02
- 1. 260E+02 O.OOOE+00 O.OOOE+00 1.260E+02 1.260E+02 1.260E+02 O.O00E+OO O.OOOE+00 8.400E+03 1.OOOE-04 3.OOOE+01
- 5. 50OE-O1 2.725E-01
- 6. 571E-01 1.181E-01 1.OOOE+0O not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used 5.00OE+01 DCNUCC(12) 5.000E+01 a-a DCNUCU(12,1) 5.000E+01 a-DCNUCS(12)
O.OOOE+00 7.224E-04 2 ALEACH(12)
O.OOOE+00 not used a SOLUBK(12) a5.0008E+01 aDCNUCC(13) 5.000E+01 aDCNUCU(13,1) a5.OOE+01 a DCNUCS(13)
O,.00E+00 7.224E-04 ALEACH(13)
O.OOOE+00 not used a SOLUBK(13) 8 400E+03 INHALR 1.OOOE-04 MLINH a 3.O00E+01 ED a 4.000E-01 SHF3 a 7.000E-01 a-a SHF1 a 5.000E-01 a-a FIND a 2.500E-01 a--
FOTD 1.000E+00 a
>0 shows circular AREA.
FS a 5.0OOE+01 aRADSHAPE(
1) 7.071E+01 a-a RADSHAPE(
2) 0.000E+00 RADSHAPE( 3)
O.O0OE+00 RADSHAPE( 4) a0.0O00E+00 a---
AD_.SHAPE(
S) 0.OOOE+00 a RADSHAPE(
6) 0.O0OE+00 a-a RADSHAPE(
7)
SO.O000E+00 aRADSHAPE(
8) a 0.000E+00 a-a BADSHAPE(
9) a0.O000+00 a3 RAD...SHAPE(10) 0.OOOE+00 3
aADSHAPE(11) a 0.OOOE+00 a RADSHAPE(12) 1.OO0E+00 FRACA( 1) 2 2.732E-01 FRACAC(
2) 0.000E+00 a-aFPRACA(
3) 0.O00E+00 FPRACA( 4) 0.OOOE+00
-FRACA(
5)
Page 59
Bartleft Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 R017 I Ring 6
not used 0.OOOE+00 FRACA( 6)
R017 3 Ring 7
not used O.OOOE+00 FRACA( 7)
R017 l
Ring 8
not used O.OOOE+O0 3 FRACA( 8)
R017 3 Ring 9
not used O.0OOE+0Q 2-FRACA(
9)
R017 I Ring 10 not used O.OOOE+00 FRACA(IO)
ROl7 3 Ring 11 not used O.0000E+0 FRACA(11)
R017 l
Ring 12 not used O.OOE+O3 FRACA(12) 3 33 33 1RESRAD, version 6.5 T-Limit = 30 days 11/28/2011 13:35 Page 8
Summary HB soil DCGL_Cm246 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM246 DCGL\\HB SOIL DCGLSCM246.RAD Site-Specific Parameter Summary (continued) 0 3
3 User Used by RESRAD Parameter Menu 3 Para*eter..................
Input
- 3. Default
(
(If different from user input)
Name R018 Fruits, vegetables and grain consumption (kg/yr)
' 1.120E+02 1.600E+02 DIET(l)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 DIET(2)
ROi8 Milk consumption (L/yr) 2.330E+02 9.200E+01 DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 DIET(S)
R018 other seafood consumption (kg/yr) 9.000E-01 9.000E-01 DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 SOIL RO18 Drinking water intake (L/yr) 4.785E-02 5.100E+02 DWI RO18 Contamination fraction of drinking water 1.000E+0O 1.000E+00 FDW R018 Contamination fraction of household water not used 1.000E+00 FHHW R018 Contamination fraction of livestock water 1.000E+00 l.OOOE+00 FLW RO18 Contamination fraction of irrigation water 1.000E+00 1.000E+00 FIRW R018 Contamination fraction of aquatic food 1.0O0E+00 5.000E-01 FR9 R018 Contamination fraction of plant food 1.000E+00 3-1 FPLANT R018 Contamination fraction of meat 1.0OOE+00 3-1 FMEAT R018 Contamination fraction of milk 1.O00E+00 :-1 FMILK ROI9 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.S00E+01I LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01
- LW5I ROi9 Livestock water intake for milk (L/day) 6.000E+013 1.600E+02 I LWI6 R019 Livestock soil intake (kg/day)
S.OOE-01 5.OOOE-01 3 LSI R019 Mass loading for foliar deposition (g/m**3) 4.OOOE-04 1.00DE-04 MLFD ROi9 Depth of soil mixing layer (m) 2.300E-01 1.50OE-01 DM R019 Depth of roots (m) 1.220E+00 9.00DE-01 DROOT R019 Drinkino water fraction from ground water 1.000E+00 1.000E+00 FGWDW ROI9 Household water fraction from ground water not used I.000E+00 FOFGWHH R019 Livestock water fraction from ground water 1.000E+00 1.0OOE+00 3 FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 FGWIR Ri9B wet weight crop yield for Non-Leafy (kg/m**2) 1.7SOE+00 7.000E-01
'V(1)
Ri9B wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00E YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 3 TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.OOOE-02 TE(3)
R19s Translocation Factor for Non-Leafy I1.0OE-01 1.000E-01 TIV(1)
R19B Translocation.Factor for Leafy 1.0OOE+00 1.OOOE+00 TIV(2)
R198 Translocation Factor for Fodder 1.OOOE+00 I1.OOOE+00 TIV(3)
Ri9g Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 RDRY(1)
Ri9B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 RDRY(2)
Rigs Dry Foliar Interception Fraction for Fodder 3.SO0E-01 2.500E-01 RDRY(3)
R19B wet Foliar Interception Fraction for Non-Leafy
.* 3.500E-01 2.S00E-01 RWET(1)
Ri9B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.50OE-01 2.S00E-01 RWET(3)
R19B weathering Removal constant for vegetation 3.300E+01 2.000E+01 WLAM C14 C-12 concentration in water (g/cm**3) not used 2.OOOE-05 C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.OOOE-02 C12CZ C14 Fraction of vegetation carbon from soil
' not used 2.000E-02 CSOIL 1RESRAD, Version 6.5 T<' Limit = 30 days 11/28/2011 13:35 Page 9
Summary HB soil DCGLCm246 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM246 DCGL\\HB SOIL DCGLCM246.RAD Site-Specific Parameter Summary (continued)
O user used by RESRAD 3 Parameter menu Parameter Input 3Default (if different from user input) 3 Name C14 Fraction of vegetation carbon from air not used 9.800E-01 CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-OI 3 DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.OOOE-07 EEVSN C14 C-12 evasion flux rate from soil (i/sec) not used 1.OOOE-1O REVSN C14 Fraction of grain in beef cattle feed not used 8.00ED1-AVFG4 C14 Fraction of grain in milk cow feed not used 2.00OE-01 AVFG5 STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 I1.400E+01 STORT(1)
STOR Leafy vegetables 1.0O0E+00 I1.000E+00 STORT(2)
STOR Milk 1.OOOE+00 I1.OOOE+00 STORT(3)
STOR Meat and poultry 2.000E+01 2.000E+01 STORT(4)
STOR Fish 7.000E+00 7.000E+00 STORT(S)
STOR Crustacea and mollusks 7.O00E+00 7.OOOE+00 STORT(6)
STOR Well water 1.000E+00 1.000E+00 STORT(7)
STOR Surface water.
1.OOOE+00 1.OOOE+00 STORT(8)
STOR Livestock fodder 4.500E+01 4.500E+01 STORjT(g)
R021 Thickness of building foundation (m) not used 1.500E-01 FLOORI R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 DENSFL R021 Total porosity of the cover material not used 4.000E-01 TPCV R021 Total porosity of the building foundation I not used 1.000E-01 TPFL R021 volumetric water content of the cover material not used 5.000E-02 PH2OCV R021 volumetric water content of the foundation not used 3.OOOE-02 PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
3 R021I in cover material not used 2.OOOE-06 DIFCV R021 in foundation material not used 3.OOOE-07 DIFFL R021I in contaminated zone soil not used 2.OOOE-06 DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.OOOE+00 HMIX RO21 Average building air exchange rate (1/hr) not used S.0OOE-01 REXG R021 Height of the building (room)
(m) not used 3 2.500E+00 HRM R021 Building interior area factor not used O.000E+O0 FAI R021 Building depth below ground surface (m) not used 1-1.0ODE+00 DMFL R021 Emanating power of Rn-222 gas 3 not used I 2.500E-01 EMANA(1)
R021 Emanating power of Rn-220 gas not used 3 1.500E-01 EMANA(2)
TITL Number of graphical time points 32 NPTS t BART L ETT Page 60
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 TITL Maximum number of integration points for dose 17 3
LYMAX TITL Maximum number of integration points for ris3 k--
KYMAX 1RESRAD, Version 6.5 T. Limit = 30 days 11/28/2011 13:35 Page 10 Summary : HB soil DCGLCm246 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM246 DCGL\\HB SOIL DCGLCM246.RAD Summary of Pathway Selections
.pfdway.
. user eecion.
1-external gamma active 2
inhalation (w/o radon)'
active 3
plant ingestion 3
active 4
meat ingestion active 5
milk ingestion 3
active 6
aquatic foods 3
active 7
drinking water active 8
soil ingestion 3
active 9
radon 3
suppressed Find peak pathway doses active IRESRAD, version 6.5 Ta Limit = 30 days 11/28/2011 13:35 Page 11 Summary : HB soil DCGLCm246 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM246 DCGL\\HB SOIL DCGLCM246.RAD contaminated Zone Dimensions Area:
30000.00 square meters Thickness:
2.67 meters Cover Depth:
0.00 meters InitialSoil4 Con.centrations.0pi/
XAXXX5XXXXXAAXXXXXXXXXXSXX AAAAAA Ce-246 1.OOOE4-00 1RESRAD, Version 6.5 Tx, Limit = 30 days 11/28/2011 13:35 Page 1
Probabilistic results summary : HE soil DCGLCm246 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM246 DCGL\\HB SOIL DCGLCM246.RAD Table of Contents Part VI: Uncertainty Analysis illtiftifilf ttiiliItii1*tfl ORESBAD Uncertainty Analysis Results Probabilistic Input...
2 Total Dose...
4 Total Risk..........................................
5 Dose vs Pathway:
Ground External...................
6 Dose vs Pathway:
Inhalation (w/o Radon)............
7 Dose vs Pathway:
Radon (Water Ind.)................
8 Dose vs Pathway:
Plant (Water Ind.)................
9 Dose vs Pathway:
Meat (water Ind.)................
10 Dose vs Pathway:
Milk (water Ind.)................
11 Dose vs Pathway:
Soil Ingestion....................
12 Dose vs Pathway:
Water Ingestion....................
13 Dose vs Pathway:
Fish Ingestion.....................
14 Dose vs Pathway:
Radon (Water Dep.)................
15 Dose vs Pathway:
Plant (Water Dep.)................
16 Dose vs Pathway:
Meat (water Dep.)................
17 Dose vs Pathway:
Milk (water Dep.)................
18 Cumulative Probability Summary.......................
19 Summary of dose at graphical times, reptition 1...
20 Peak of the mean dose at graphical times.............
21 Correlation and Regression coefficients (if any)...
22 1RESRAD, Version 6.5 Tx Limit = 30 days 11/28/2011 13:35 Page 2
Probabilistic results summary : HE soil DCGLCm246 File : C:\\RESRADOFAMILY\\RESRAD\\6.5\\USERFILES\\CM246 DCGL\\HB SOIL DCGLCM246.RAD Probabilistic Input ONumber of Sample Runs: 2000 Number Name AAMAAAA"A'AAA' 1
DENSCZ 2
TPCZ 3
HCCZ 4
BCZ 5
EVAPTR 6
RI 7
DENSAQ 8
TPSZ 9
EPSZ 10 NCSZ 11 BSz 12 DWIBWT 13 UW 14 H(1) 15 DENSUZ(1) 16 TPUZ(1) 17 EPUZ(1) 18 HCUZ(1) 19 BUZ(1) 20 MLINH
.00003
.8119 21 SHF3 22 SHF1 23 DM 24 Yv(1) 25 WLAM 26 RWET(2) 27 DCACTC(1) 28 DCACTU1(1) 29 OCACTS(1) 30 DCACTC(5) 31 DCACTUI(5) 32 DCACTS(5) 33 DCACTC(6) 34 DCACTU1(6) 35 DCACTS(6) 36 DCACTC(7) t BARTLETT Distribution Parameters hA.AAAA~j X~AXXXXXSXXXXXXX 5A55R5X55A&XX BOUNDED NORMAL 1.5635
.2385 BOUNDED NORMAL
.41
.09 BOUNDED LOGNORMAL-N 1.36 2.17 BOUNDED LOGNORMAL-N 1.73
.323 UNIFORM
.5
.75 UNIFORM
.36
.76 BOUNDED NORMAL 1.5105
.1855 BOUNDED NORMAL
.43
.0699 BOUNDED NORMAL
.342
.0705 BOUNDED LOGNORMAL-N
.362 1.59 BOUNDED LOGNORMAL-N 1.96
.265 TRIANGULAR 6
10 UNIFORM 1173 1973 UNIFORM 0
8.08 BOUNDED NORMAL 1.5635
.2385 BOUNDED NORMAL
.41
.09 BOUNDED NORMAL
.315
.0905 BOUNDED LOGNORMAL-N 1.36 2.17 BOUNDED LOGNORMAL-N 1.73
.323 CONTINUOUS LINEAR 8
0
.00004
.9495
.00006
.9937
.000076
.9983 UNIFORM
.15
.95 BOUNDED LOGNORMAL-N
-1.3
.59 TRIANGULAR 0
.15 TRUNCATED LOGNORMAL-N.56
.48 TRIANGULAR 5.1 18 TRIANGULAR
.06
.67 TRUNCATED LOGNORMAL-N 8.82 1.82 TRUNCATED LOGNORMAL-N 8.82 1.82 TRUNCATED LOGNORMAL-N 8.82 1.82 TRUNCATED LOGNORMAL-N 7.78 2.78 TRUNCATED LOGNORMAL-N 7;78 2.76 TRUNCATED LOGNORMAL-N 7.78 2.76 TRUNCATED LOGNORMAL-N 5.2 1.68 TRUNCATED LOGNORMAL-N 5.2 1.68 TRUNCATED LOGNORMAL-N 5.2 1.68 TRUNCATED LOGNORMAL-N 6.86 1.89
.827 2.3
.1319
.6881
.00478 3190 2.08 15.3
.937 2.084
.214
.646
.124
.56
.0106 195 3.02 15.5 30
.827 2.3
.1319
.6881
.0349
.594
.00478 3190 2.08 15.3 0
.000008
.0001 1
.044 1
.6
.001
.999 84
.95
.001
.999
.001
.999
.001
.999
.001
.999
.001
.999
.001
.999
.001
.999
.001
.999
.001
.999
.001
.999
.0151
.000016
.1365 Page 61
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 37 DCACTU1(7)
TRUNCATED LOGNORMAL-N 6.86 1.89
.001 38 DCACTS(7)
TRUNCATED LOGNORMAL-N 6.86 1.89
.001 39 DCACTC(10)
TRUNCATED LOGNORMAL-N 8.17 1.7
.001 40 DCACTU1(10)
TRUNCATED LOGNORMAL-N 8.17 1.7
.001 41 DCACTS(10)
TRUNCATED LOGNORMAL-N 8.17 1.7
.001 42 DCACTC(11)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001 43 DCACTU1(11)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001 44 DCACTS(11)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001 45 DCACTC(12)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001 46 DCACTU1(12)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001 47 DCACTS(12)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001 48 DCACTC(13)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001 IRESRAD, version 6.5 Tv Limit = 30 days 11/28/2011 13:35 Page 3
Probabilistic results summary : HB soil DCGLCm246 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM246 DCGL\\HB SOIL DCGLCM246.RAD Probabilistic Input (cont.)
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999 Number AAAAAA 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 f1t111 Name DCACTU1(13)
OCACTS(13)
BRTF(96,2)
BRTF(96, 3)
BBIO(96,1)
BRTF(82, 1)
BRTF(82,2)
BRTF(82,3)
BBIO(82,1) 8RTF(84, 1)
BRTF(84,2)
BRTF(84,3)
BBIO(84,1)
BRTF(94,1)
BRTF(94,2)
BRTF(94, 3)
BBIO(94,1)
BRTF(88, 1)
BRTF(88, 2)
BRTF(88,3)
BBIO(88,1)
BRTF(90, 1)
BRTF(90,2)
BRTF(90, 3)
BBIO(90,1)
BRTF(92, 1)
BRTF(92,2)
BRTF(92,3)
BBIO(92, 1) illifffitififff111fi1if Distribution TRUNCATED LOGNORXAL-N TRUNCATED LOGNORMAL-N TRUNCATED LOGNORMAL-N TRUNCATED LOGNORMAL-N LOGNORMAL-N TRUNCATED LOGNORMAL-N TRUNCATED LOGNORMAL-N TRUNCATED LOGNORMAL-N LOGNORMAL-N TRUNCATED LOGNORMAL-N TRUNCATED LOGNORMAL-N TRUNCATED LOGNORMAL-N LOGNORMAL-N TRUNCATED LOGNORMAL-N TRUNCATED LOGNORMAL-N TRUNCATED LOGNORMAL-N LOGNORMAL-N TRUNCATED LOGNORMAL-N TRUNCATED LOGNORMAL-N TRUNCATED LOGNORMAL-N NALOGNORMALN TRUNCATED LOGNORMAL-N TRUNCATED LOGNORMAL-N TRUNCATED LOGNORMAL-N LOGNORMAL-N TRUNCATED LOGNORMAL-N TRUNCATED LOGNORMAL-N TRUNCATED LOGNORMAL-N LOGNORMAL-N Parameters 4.84 3.13
.001
.999 4.84 3.13
.001
.999
-10.82 1
.001
.999
-13.12
.9
.001
.999 3.4 1.1
-5.52
.9
.001
.999
-7.13
.7
.001
.999
-8.11
.9
.001
.999 S.7 1.1
-6.9
.9
.001
.999
-5.3
.7
.001
.999
-7.82
.7
.001
.999 4.6 1.1
-6.91
.9
.001
.999
-9.21
.2
.001
.999
-13.82
.5
.001
.999 3.4 1.1
-3.22
.9
.001
.999
-6.91
.7
.001
.999
-6.91
.5
.001
.999 3.9 1.1
-6.91
.9
.001
.999
-9.21 1
.001
.999
-12.21
.9
.001
.999 4.6 1.1
-6.21
.9
.001
.999
-7.13
.7
.001
.999
-7.82
.6
.001
.999 2.3 1.1 lifiliftflftllifiiiltiitfl~tltlftliliffti IRESRAD1 version 6.5 T<, Limit = 30 days 11/28/2011 13:35 Page 21 Probabilistic results summary : HB soil DCGL.Cm246 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CM246 DCGL\\HB SOIL DCGLCM246.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1
0.OOOE+00 9.700E-01 t
BARTLETT Page 62
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Co-60 Results:
IRESRAD, Version 6.5 Ta Limit = 30 days 11/26/2011 14:16 Page 1
Summary HB soil DCGLCo-60 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CO6O DCGL\\HB SOIL DCGLCO60.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines ftfifttififfiliftli t-filifiliffltlttittitfliftfittttf Dose Conversion Factor (and Related) Parameter Summary...
2 site-specific Parameter Summary............................
3 summary of Pathway Selections..............................
7 Contaminated Zone and Total Dose Summary...................
8 Total Dose Components Time = 0.OOOE+00..
9 Time = 1.000E+00.....................................
10 Time = 3.OOOE+O0.....................................
11 Time = 1.000E+01....................................
12 Time = 3.000E+01.....................................
13 Time = 1.000E+02.....................................
14 Time = 3.000E+02-.....................................
15 Time = 1.O00E+03....................................
16 Dose/Source Ratios Summed Over All Pathways..............
17 Single Radionuclide Soil Guidelines.......................
17 Dose Per Nuclide Summed over All Pathways................
18 Soil Concentration Per Nuclide...........................
18 1RESRAD, version 6.5 To Limit = 30 days 11/26/2011 14:16 Page 2
Summary : HB soil DCGLCo-60 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\CO60 DCGL\\HB SOIL DCGLCo60.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: HB DCGL.Co60 Plus FGR 12 & FGR 11 0
3 Current 3
Base Parameter Menu I Parameter value#
3 case*'
Name A-1 OCF's for external ground radiation, (mrem/yr)/(pCi/g)
A-1 Co-60 (Source:
FGR 12) 1.622E+01 1.622E+01 DCF1(
1)
B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 co-60 2.190E-04 2.190E-04 DCF2(
1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Co-60 2.690E-05 2.690E-05 DCF3(
1)
D-34 Food transfer factors:
D-34 Co-60
, plant/soil concentration ratio, dimensionless 1.460E-01 8.OOOE-02 RTF(
1,1)
D-34 Co-60 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.860E-02 2.OOOE-02 RTF(
1,2)
D-34 Co-60 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.OOOE-03 2.OOOE-03 RTF(
1,3)
O-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Co-60
, fish 3.000E+02 3.000E+02 BIOFAC(
1,1)
D-5 Co-60
,crustacea and mollusks I 2.OOOE+02 2.000E+02 BIOFAC(
1,2)
- For DCFI(xxx) only, factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Default.Lib w/o Associate Nuclide contributions.
1RESRAD, version 6.5 Ta Limit = 30 days 11/26/2011 14:16 Page 3
Summary : HB soil DCGL-o-60 File
- C:\\RESRADFAMILY\\RESBAD\\6.5\\USERFILES\\CO60 DCGL\\HB SOIL DCGLCO60.RAD Site-Specific Parameter Summary 0
User used by RESRAD Parameter Menu 3Parameter input
.Default (if different from User input)
M ane M *..~ ~~~~~~~..........................................
Pa ~
r..........
ut..........
- a
...* ~ if m
u*.......... N *............
R011 ' Area of contaminated zone (m**2) 3.OOOE+04 1.000E+04 AREA ROll Thickness of contaminated zone (m) 2.670E+00 2.000E+00 I THICKO R011 Fraction of contamination that is submerged 0.OOE+00 O.000E+00 I SUBMFRACT R011 Length parallel to aquifer flow (i) 1.950E+02 1.O00E+02 LCZPAQ ROll Basic radiation dose limit (mrem/yr) 2.500E+01 3.OOOE+01 BRDL R011 Time since placement of material (yr)
O.OOOE+00 O.OOOE+00 3 TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 T( 2)
ROll Times for calculations (yr) 3.000E+00 3.OOOE+00 T(
3)
R011 Times for calculations (yr) 1.OOOE+01 1.000E+01 T( 4)
Roll Times for calculations (yr) 3.000E+01 3.000E+01 T(
5)
R011 ' Times for calculations (yr) l.OOOE+02 1.000E+02 T( 6)
ROll 3 Times for calculations (yr) 3.00E+02 3.OOOE+02 3 T(
7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 T( 8)
Roll 3 Times for calculations (yr) not used 0.OOOE+00 T( 9)
R011 Times for calculations (yr) not used 0.000E+00 T(10)
R012 Initial principal radionuclide (pCi/g):
Co-60 1.000E+00 O.OOOE+O0 S1(1)
RO2 Concentration in groundwater (pCi/L):
Co-60 not used 0.000E+00 w1( 1)
R013 Cover depth (m)
O.00E+O0 O.OOOE+00 COVERO R013 Density of cover material (g/cm*
3 3) 3 not used 1.500E+O0 DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 VCV ROl3 Density of contaminated zone (g/cm**3) 1.564E+00 1.500E+00 DENSCZ R013 contaminated zone erosion rate (m/yr) 2.200E-03 1.000E-03 VCZ R013 Contaminated zone total porosity 4.100E-01 4.OOOE-01 TPCZ ROl3 Contaminated zone field capacity 9.500E-02 2.000E-01I FCCZ ROl3 Contaminated zone hydraulic conductivity (m/yr) 3.900E+00 1.000E+01 HCCZ ROl3 Contaminated zone b parameter
' 5.600E+00 5.300E+00 BCZ R013 Average annual wind speed (m/sec) 3.040E+00 2.000E+00 WIND ROl3 Humidity in air (g/m**3) not used 8.000E+00 HUMID ROl3 Evapotranspiration coefficient 6.250E-01 5.000E-01 EVAPTR ROl3 Precipitation (m/yr) 9.100E-01 1.000E+00 PRECIP R013 Irrigation (m/yr) 5.600E-01 2.000E-01 RI ROl3 Irrigation mode overhead overhead IDITCH R013 Runoff coefficient 5.000E-01 2.000-E01 RUNOFF ROl3 watershed area for nearby stream or pond (m**2) 2.520E+07 1.O00E+06 WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 EPS R014 Density of saturated zone (g/cm**3)
I.S10E+00 1.500E+00 DENSAQ R014 Saturated zone total porosity 4.300E-01 4.OOOE-01 TPSZ R014 Saturated zone effective porosity 3.420E-01 2.000E-01 EPSZ R014 Saturated zone field capacity 8.800E-02 2.000-E01 FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 2.880E+01 1.O00E+02 MCSZ 40 BAR.TL.ETTPae6 Page 63
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 RO14 Saturated zone hydraulic gradient 2.OOOE-03 2.OOQE-02 R014 ' Saturated zone b parameter 7.100E+O0 5.300E+00 R014 w
water table drop rate (m/yr) 1.0OOE-03 1.OOOE-03 R014
' well pump intake depth (m below water table) 1.OOOE+01 1.OOOE+01 RO14 Model: Nondispersion (ND) or Mass-Balance (MB) 3 ND 3 ND R014 well pumping rate (m t
3/yr) 1.573E+03 I 2.500E+02 IRESRAD., Version 6.5 T" Limit ý 30 days 11/26/2011 14:16 Page 4
Summary : HB soil DCGLCo-60 File
- C:\\RESRADOFAMILY\\RESRAD\\6.5\\USERFILES\\CO60 DCGL\\HB SOIL DCGL_CO60.RAD HGWT BSZ 3 VWT DWIBWT MODEL UW 0
3 Menu 3 aaee R01S Number of unsaturated zone strata RO15 3 Unsat. zone 1, thickness (m)
R015 Unsat. zone 1, soil density (g/cm**
R015 Unsat. zone 1, total porosity R015 Unsat. zone 1, effective porosity R015 Unsat. zone 1, field capacity R015 Unsat. zone 1, soil-specific b para R015 Unsat. zone 1, hydraulic conductivi R016 Distribution coefficients for Co-60 R016 Contaminated zone (cm**3/g)
R016 unsaturated zone 1 (cm**3/g)
R016 Saturated zone (cm*
3 3/g)
R016 Leach rate (/yr)
R016 Solubility constant R017 Inhalation rate (m**3/yr)
R017 Mass loading for inhalation (g/m**3 ROl7 3 Exposure duration R017 3 Shielding factor, inhalation R017 3 Shielding factor, external gamma R017 Fraction of time spent indoors ROll Fraction of time spent outdoors (on R017 Shape factor flag, external gamma R017 Radii of shape factor array (used R017 Outer annular radius (m),
ring 1
R017 Outer annular radius (i) ring 2
ROl7 Outer annular radius (i) ring 3
R017 Outer annular radius (m),
ring 4
R017 Outer annular radius (m),
ring 5
R017 Outer annular radius (m),
ring ROl7 Outer annular radius (m),
ring 7
R017 Outer annular radius (m),
ring R017 Outer annular radius (m),
ring 9
R01 Outer annular radius (m),
ring 10 RO17 Outer annular radius (m),
ring 11 RO17 Outer annular radius (m),
ring 12 1RESRAD, version 6.5 T1 Limit = 30 day Summary : HB soil DCGLco-60 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USER Site-Specific Parameter Summary (continued)
User 3
used by RESRAD 3
Parameter nput Default (if different from user inpu.t) '
Na..eN 1
1 NS 4.040E+00 4.OOOE+0' H(l)
'3) 1.564E+OO 1.50OE+O0 DENSUZ(1) 4.100E-Ol 4.OOOE-Ol TPUZ(1) 3.150E-01 2.000E-01
- EPUZ(1) 9.SO0E-02 2.OOOE-01 FCUZ(1) meter 5.600E+00 5.300E+00 BUZ(l) ty (m/yr) 3.900E+00 1.OOOE+01 HCUZ(1) 2.350E+02 1.OOOE+03 DCNUCC( 1) 2.350E+02 ' 1.OOOE+O3 DCNUCU( 1,1)
I 2.350E+02 3 1.000E+03 DCNUCS(
1) 0.OOOE+O0 0.000E+0O 3.876E-04 ALEACH( 1) 0.OO0E+O0 O.O0OE+OO '
not used SOLUBK(
1) 8.400E+03 8.400E+03 INHALR l.OOOE-04 1.000E-04 3---
MLINH 3.000E+O1 3.O00E+Ol ED 5.500E-01 4.000E-01 SHF3 3.980E-01 7.000E-l1 SHF1 6.571E-01 5.00E-01 FIND n site) 1.181E-01 2.500E-01 FOTD 1.OOOE+0O 1.OOOE+OO
>0 shows circular AREA.
FS 3 not used 5.OOOE+O1 RAD.SHAPE(
1)
' not used 7.071E+01 RADSHAPE(
2) 3 not used O.O0OE+00 RADSHAPE(
3) not used O.OOOE+OO RAD.SHAPE(
4) not used 0.000E+O0 RADSHAPE(
5) not used O.000E+OO RADSHAPE(
6) 3 not used O.OOOE+OO AD.SHAPE(
7) not used O.OOOE+OO BAD-SHAPE(
8) not used O.OOOE+O0 BADSHAPE(
9)
I not used O.OOOE+0O RAD.SHAPE(IO) 3 not used O.OOOE+O0 RADSHAPE(11)
- not used O.OOOE+O0 RADSHAPE(12) s 11/26/2011 14:16 Page 5
RFILES\\CO60 DCGL\\HB SOIL DCGL_CO6O.PAD 0
menu Parameter RO17 'Fractions of annular areas within R017 Ring 1
R017 Ring 2
R017 Ring 3
R017 Ring 4
R017 Ring 5
R017 Ring 6
ROll Ring 1
R017 Ring B
R017 Ring 9
R017 Ring 10 R017 Ring 11 R017 Ring 12 R018
' Fruits, vegetables and grain consu R018 Leafy vegetable consumption (kg/yr R018 'Milk consumption (L/yr)
R018 3 Meat and poultry consumption (kg/y R018 Fish consumption (kg/yr)
R018 other seafood consumption (kg/yr)
R018 3 Soil ingestion rate (g/yr)
R018 3 Drinking water intake (L/yr)
R018 Contamination fraction of drinking R018 3 Contamination fraction of househol R018 Contamination fraction of livestoc R018 Contamination fraction of irrigati RO18 Contamination fraction of aquatic R018
' Contamination fraction of plant fo R018
' Contamination fraction of meat R018 Contamination fraction of milk R019 ' Livestock fodder intake for meat C RO19 3 Livestock fodder intake for milk C R019 ' Livestock water intake for meat (L R019 ' Livestock water intake for milk (L R019 3 Livestock soil intake (kg/day)
R019
' Mass loading for foliar deposition R019 ' Depth of soil mixing layer (m)
R019 Depth of roots (m)
R019 Drinking water fraction from groun R019 Household water fraction from grou R019 Livestock water fraction from grou R019 Irrigation fraction from ground wa R19B ' Wet weight crop yield for Non-Leaf R19B wet weight crop yield for Leafy R19B wet weight crop yield for Fodder R19B 3 Growing Season for Non-Leafy (yea R19B ' Growing Season for Leafy (yea Rl9B Growing Season for Fodder (yea L BARTLETT Site-specific Parameter Summary (continued)
User used by RESRAD I
D......
...efault
.( f..
fferent..from..use.r..input)
AREA:
not used
'.OOOE+00 not used 2.732E-01 3 not used 3 O.OOOE+OO not used 0.OOE+OO not used O.OOOE+OO 3 not used O.OOOE+OO not used 3 O.OOOE+OO not used
' O.OOOE+OO 3 not used
' O.O0OE+OO not used O.OOOE+00 3 not used O.OO0E+OO not used
'O.OOE+OO mption (kg/yr) 1.120E+02 1.600E+02
' 2.140E+01 3 1.400E+01 3 2.330E+02 ' 9.200E+01--
r) 6.510E+O1 3 6.300E+01 2.060E+01 3 5.400E+O0 3 9.OOOE-O1 ' 9.OOOE-01 1.826E+01 3.650E+01 3 4.785E+02 S.100E+02 3 water 1.OOOE+OO 1.OOOE+O0 d water not used 1.O0OE+00 k water 1.OOOE+O0 10.O0E+OO on water 1.OOOE+0O0 1.OOE+OO food 1.000E+OO 5,000E-01 od 1.OO0E+00 '-1 31.OOOE+00 '-1
- 1.OOOE+O0 '-1 kg/day) 3 2.710E+01 3 6.800E+01 kg/day)
' 6.320E+01 3 5.500E+01
/day) 3 5.060E+01 3 5.OOOE+Ol
/day) 6.OOOE+01 3 1.600E+02 5.O0OE-01 5.OOOE-01 (g/m**3) 4.OOOE-04 ' 1.OOOE-04 3 2.300E-01 3 1.SOOE-Ol 1.220E+00 3 9.00OE-01 d water 1.OOOE+OO ' 1.OOOE+O0 3 nd water not used 1.OOOE+O0 nd water 1.OO0E+OO 1.OOOE+O0 ter I.O00E+0O 1.OOOE+O0 3 y (kg/m**2) 1.750E+00 7.OOOE-01 (kg/m**2) 2.889E+00 1.500E+00 (kg/m**2) 1.887E+00 1.1OOE+O0 rs) 2.460E-01 1.70OE-Ol rs) 1.230E-01 2.500E-01
.rs) 8.200E-02 8.OOOE-O2 L*
Parameter 3 Name SFRAcACA 1)
FRACA( 2)
FRACA( 3)
FBACA( 4)
FRAcA( 5)
FRACA( 6) 3EPACA( 7)
FPACA 8)
PFACA( 9)
FRACA(10) 3 FPACA(11) 3 FPACA(12) 3 DIET(1) 3 DIET(2) 3 DIET(3)
DIET(4)
- DIET(5)
DIET(6)
SOIL DWI FDW FHHW FLW FIRW 3 FR9 FPLANT FMEAT 3 FMILK
- LFIS 3 LFI6 LWIS LwI6 LSI MLFD DM DROOT FGWDW FGWHH FGWLW FGWIR YV(1)
Yv(2)
YV(3)
TE(1)
SAA Page 64
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 1RESRAD, Version 6.5 Ta Limit = 30 days 11/26/2011 14:16 Page 6
Summary HB soil DCGL-Co-60 File C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\CO60 DCGL\\HB SOIL DCGL_CO60.RAD Site-Specific Parameter Summary (continued) 0 3
3 User 3
used by RESRAD 3 Parameter Menu Parameter Inp.ut
- 3. Default (if diffe rent from user input)
Name R19B Translocation Factor for Non-Leafy 1.OOOE-O1 3 1.OOOE-01 R19B Translocation Factor for Leafy 1.OOOE+00 1.O0OE+03 R19B Translocation Factor for Fodder 1.000E+00 1.OOOE+O0 RI9B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 3 2.500E-01 R19B 3 Dry Foliar Interception Fraction for Leafy 3.500E-01 2.SOOE-01 R19B 3 Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 R19B Wet Foliar Interception Fraction for Non-Leafy 3.SOOE-01 2.500E-01 R19B 3 Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 R19B Weathering Removal Constant for Vegetation 3.300E+01 2.OOOE+01 C14 C-12 concentration in water (g/cm**3) 3 not used 2.OOOE-05 C14 c-12 concentration in contaminated soil (g/g) not used 3.OOOE-02 C14 Fraction of vegetation carbon from soil not used 2.000E-02 C14 Fraction of vegetation carbon from air not used 9.800E-01 C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 C14 C-14 evasion flux rate from soil (1/sec) not used 7.OOOE-07 C14 C-12 evasion flux rate from soil (1/sec) not used I 1.OOOE-10 I C14 Fraction of grain in beef cattle feed not used 8.000E-OI 3 C14 Fraction of grain in milk cow feed not used 3 2.O0OE-01 O
STOR 3 Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 3 1.400E+01 STOR Leafy vegetables 1.OOOE+00 1.000E+00 STOR Milk 1.0OOE+00 1.00OE+O0 STOR Meat and poultry 2.000E+Q1 2.000E+O1 STOR 3 Fish I 7.0OOE+00 3 7.0OOE+O0 STOR a crustacea and mollusks 7.000E+00 7.000E+O0 STOR well water 1.000E+00 1.0OoE+O0 STOR 3 Surface water 1.000E+00 3 1.0OOE+00 STOR 3 Livestock fodder 4.500E+01 I 4.SOOE+01 R021 Thickness of building foundation (m) not used 3 1.50E-0 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 R021 Total porosity of the cover material not used a 4.000E-01 R021 Total porosity of the building foundation not used 1.OOOE-01 R021 aVolumetric water content of the cover material not used 5.000E-02 R021 Volumetric water content of the foundation not used 3.000E-02 R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.OOOE-06 R021 in foundation material not used 3 3.OOOE-07 R021 in contaminated zone soil 3 not used a 2.OOOE-06 R021 Radon vertical dimension of mixing (m)
I not used I 2.000E+00 R021 Average building air exchange rate (1/hr) a not used 35,0OOE-01 3 R021 Height of the building (room)
(m) a not used 3 2.500E+00 a R021 Building interior area factor I not used 3 0.OOOE+00 R021 Building depth below ground surface (m) a not used 3-1.OOOE+00 R021 Emanating power of Rn-222 gas 3 not used a 2.500E-01 a R021 Emanating power of Rn-220 gas 3 not used a 1.500E-01 a TIV(1)
TIV(2) 3 TIV(3)
RDRY(1)
RDRY(2)
RDRY(3)
RWET(1)
RWET(2)
RWET(3) 3 WLAM C12WTR cI2cz CSOIL CAIR 3 DMC EVSN REVSN AVFG4 AVFGS STORT(1)
STORT(2)
STORT(3)
STORJT(4)
STORiT(S)
STORT(6) a STORT(7) 3 STOT(8)
STORT(9)
FLOOR1 DENSFL 3 TPCV a TPFL 3 PH2OCV
- PH2OFL a DIFCV DIFFL DIFCZ HMIX 3 REXG 3 HRM FAI DMFL EMANAUi)
EMANA(2)
TITL Number of graphical time points 32 a
a--
NPTS IRESRAD, Version 6.5 T-Limit = 30 days 11/26/2011 14:16 Page 7
Summary : HB soil DCGL-Co-60 File
- C:\\RESRADFASIILY\\RESRAD\\6.5\\USERFILES\\CO60 DCGL\\HB SOIL DCGLCO60.RAD Site-Specific Parameter Summary (continued) 0 3
a User a
a Used by RESRAD a Parameter Menu 3 Parameter 3
input 3
De.faul.t.a (if different from user input) a Name TITL a Maximum number of integration points for dose 3
17 LYMAX TITL 3 Maximum number of integration points for risk 1
3 a--
KYMAX Summary of Pathway Selections
.Pathway a
User Selection 1-- external gamma active 2
inhalation (w/o radon)'
active 3 -- plant ingestion a
active 4
meat ingestion 3
active 5
milk ingestion active 6
aquatic foods active 7
drinking water active 8
soil ingestion active 9 --
radon suppressed Find peak pathway doses a
active ttillttftftttft IltfitttttffiifitttitttitItfililtt IRESRAD, Version 6.5 T-Limit = 30 days 11/26/2011 14:16 Page 8
Summary : HB soil DCGL-Co-60 File
- C:\\RESRAD-FAMILY\\RESRAD\\6.5\\USERFILES\\CO60 DCGL\\HB SOIL DCGL0co60.RAD Contaminated Zone Dimensions Initial Soil Concentrations, p~i/g Area:
30000.00 square meters Co-60 1.000E+00 Thickness:
2.67 meters Cover Depth:
0,00 meters 1RESRAD, Version 6.5 Ta Limit - 30 days 11/26/2011 14:16 Page Probabilistic results summary : HB soil DCGL-Co-60 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CO60 DCGL\\HB SOIL DCGLCO60.RAD Table of Contents Part VI: Uncertainty Analysis ORESRAD Uncertainty Analysis Results Probabilistic Input.................................
2 Total Dose..........................................
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Total Risk..
4 Dose vs Pathway:
Ground External...................
5 Dose vs Pathway:
Inhalation (w/o Radon)..............
6 Dose vs Pathway:
Radon (Water Ind.)..................
7 Dose vs Pathway:
Plant (Water Ind.)..................
8 Dose vs Pathway:
Meat (Water Ind.)................
9 Dose vs Pathway:
Milk (Water Ind.).................
10 Dose vs Pathway:
Soil Ingestion...................
11 Dose vs Pathway:
water Ingestion...................
12 Dose vs Pathway:
Fish Ingestion...................
13 Dose vs Pathway:
Radon (Water Dep.)...............
14 Dose vs Pathway:
Plant (water Dep.).................
.15 Dose vs Pathway:
Meat (water Dep.).................
16 Dose vs Pathway:
Milk (Water Dep.).................
17 Cumulative Probability Summary.......................
18 Summary of dose at graphical times, reptition 1....
19 Peak of the mean dose at graphical times.............
20 Correlation and Regression coefficients (if any)....
21 IRESRAD, Version 6.5 To Limit = 30 days 11/26/2011 14:16 Page 2
Probabilistic results summary : HB soil DCGL.Co-60 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CO60 DCGL\\HB SOIL DCGLCo60.RAD Probabilistic Input 0Number of Sample Runs: 2000 Number Name Distribution 1iAW SX Z BOUNDEADAAAAAA 4i NORMXALAA 1
DENSCZ BOUNDED NORMAL 2
TPCZ BOUNDED NORMAL 3
BCCZ BOUNDED LOGNORMAL-N 4
BCZ BOUNDED LOGNORt4AL-N 5
EVAPTR UNIFORM 6
RI UNIFORM 7
DENSAQ BOUNDED NORMAL 8
TPSZ BOUNDED NORMAL 9
EPSZ BOUNDED NORMAL 10 HCSZ BOUNDED LOGNORMAL-N 11 BSZ BOUNDED LOGNORMAL-N 12 DWIBWT TRIANGULAR 13 Uw UNIFORM 14 H(1)
UNIFORM 15 DENSUZ(1)
BOUNDED NORMAL 16 TPUZ(1)
BOUNDED NORMAL 17 EPUZ(1)
BOUNDED NORMAL 18 HCUZ(1)
BOUNDED LOGNORMAL-N 19 BUZ(1)
BOUNDED LOGNORMAL-N 20 MLINH CONTINUOUS LINEAR
.00003
.8119
.00004
.9495
.00006
.9937 21 SHF3 UNIFORM 22 DM TRIANGULAR 23 YV(1)
TRUNCATED LOGNORMAL-N 24 WLAM TRIANGULAR 25 RWET(2)
TRIANGULAR 26 DCACTC(1)
TRUNCATED LOGNORMAL-N 27 DCACTU1(1)
TRUNCATED LOGNORMAL-N 28 DCACTS(1)
TRUNCATED LOGNORMAL-N 29 BRTF(27,3)
TRUNCATED LOGNORMAL-N 30 BBIO(27,1)
LOGNORMAL-N fifttf tftftttttfttittittittil tttfftiifttfttiffftif Parameters 1.5635
.2385
.827 2.3
.41
.09
.1319
.6881 1.36 2.17
.00478 3190 1.73
.323 2.08 15.3
.5
.75
.36
.76 1.5105
.1855
.937 2.084
.43
.0699
.214
.646
.342
.0705
.124
.56
.362 1.59
.0106 195" 1.96
.265 3.02 15.5 6
10 30 1173 1973 0
8.08 1.5635
.2383
.827 2.3
.41
.09
.1319
.6881
.315
.0905
.0349
.594 1.36 2.17
.00478 3190 1.73
.323 2.08 15.3 8
0 0
.000008
.000076
.9983
.0001 1
.15
.95 0
.15
.6
.56
.48
.001
.999 5.1 18 84
.06
.67
.95 5.46 2.53
.001
.999 S.46 2.S3
.001
.999 5.46 2.53
.001
.999
-6.21
.7
.001
.999
.2.7 5.7tt 1.l1tttttttttttit ItttiItif
.0151
.000016
.1365 IRESRAD, Version 6.5 To Limit = 30 days 11/26/2011 14:16 Page 20 Probabilistic results summary : HB soil DCGLCo-60 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CO60 DCGL\\HB SOIL DCGLCo60.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1
0.O0OE+00 6.553E+00 W)BARTLETT Page 66
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Cs-137 Results:
1RESRAD, Version 6.S To Limit = 30 days 11/27/2011 09:09 Page 1
Summary : HB soil DCGLCs137 File
- C:\\RESRAD_.FAMILY\\RESRAD\\6.S\\USERFILES\\CSI37 DCGL\\HB SOIL DCGL_CS137.RAO Table of Contents Part I: Mixture sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary...
2 site-Specific Parameter Summary..........................
3 Summary of Pathway Selections............................
7 Contaminated Zone and Total Dose Summary.................
8 Total Dose Components Time = O.O00E+ 0..
9 Time = 1.000E+00....................................
10 Time = 3.000E+00.....................................
11 Time = 1.000E+01.....................................
12 Time = 3.000E+01.....................................
13 Time = 1.000E+02.....................................
14 Time = 3.000E+02....................................
15 Time = 1.000E+03....................................
16 Dose/Source Ratios Summed Over All Pathways...............
17 Single Radionuclide Soil Guidelines......................
17 Dose Per Nuclide Summed over All Pathways.................
.18 Soil Concentration Per Nuclide...........................
18
- IRESRAD, Version 6.5 T< Limit = 30 days 11/27/2011 09:09 Page 2
Summary : HB soil DCGLCs137 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\CS137 DCGL\\HB SOIL DCGL_CS137.RAD 0
3 Menu2 Dose Conversion Factor (and Related) Parameter Summary Dose Library: HB DCGLCS137 Plus FGR 12 & FGR 11 3
Current
............. Paýýr t r..........
V a Base Parameter Case*.
Name A-i DCF's for external ground radiation, (mrem/yr)/(pCi/g)
A-1 Ba-137m (Source: FGR 12) 3 3.606E+00 I 3.606E+00 DCFi(
1)
A-1 Cs-137 (Source: FGR 12) 7.510E-04 7.510E-04 DCF1(
2)
B-1 Dose conversion factors for inhalation, mrem/pCi:
B-I Cs-137+D 3.190E-05 3.190E-05 DCF2(
1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Cs-137+D 5.000E-05 5.000E-05 DCF3(
1)
D-34 Food transfer factors:
D-34 Cs-137+D
, plant/soil concentration ratio, dimensionless 7.820E-02 4.000E-02 RTF(
1,1)
D-34 Cs-137+D beef/livestock-intake ratio, (pCi/kg)/(pCi/d) a 6.520E-02 3 3.000E-02 RTF(
1,2)
D-34 Cs-137+D milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.390E-02 8.000E-03 RTF(
1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Cs-137+D
, fish 2.OOOE+03 2.000E+03 BIOFAC(
1,1)
D-5 Cs-137+D
, crustacea and mollusks 1.O00E+02 1.000E+02 BIOFAC(
1 2)
- For DCF1(xxx) only, factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Default.Lib w/o Associate Nuclide contributions.
1RESRAD, Version 6.5 To Limit = 30 days 11/27/2011 09:09 Page 3
summary : HB soil DCGLCs137 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CS137 DCGL\\HB SOIL DCGLCS137.RAD 0
menuPamer R011 Area of contaminated zone (m**2)
R011 Thickness of contaminated zone (m)
R011 Fraction of contamination that is submer R011 Length parallel to aquifer flow (m)
R011 3 Basic radiation dose limit (mrem/yr)
R011 Time since placement of material (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 3 Times for calculations (yr)
R011 Times for calculations (yr)
R011 3 Times for calculations (yr)
R011 Times for calculations (yr)
R011 ' Times for calculations (yr)
R011 Times for calculations (yr)
R011 2 Times for calculations (yr)
R012 Initial principal radionuclide (pCi/g):
R012 Concentration in groundwater (pCi/L):
R013 Cover depth (m)
RO13 Density of cover material (g/cm**3)
R013 Cover depth erosion rate (m/yr)
R013 Density of contaminated zone (g/cm**3)
R013 a Contaminated zone erosion rate (m/yr)
R013 Contaminated zone total porosity R013 Contaminated zone field capacity R013 2 Contaminated zone hydraulic conductivity R013 I Contaminated zone b parameter R013 3 Average annual wind speed (m/sec)
R013 3 Humidity in air (g/m**3)
R013 I Evapotranspiration coefficient R013 Precipitation (m/yr)
R013 I Irrigation (m/yr)
R013 Irrigation mode R013 Runoff coefficient ROl3 Watershed area for nearby stream or pond R013 Accuracy for water/soil computations R014 Density of saturated zone (g/cm**3)
R014 Saturated zone total porosity R014 Saturated zone effective porosity R014 Saturated zone field capacity Site-Specific Parameter Summary 3
User 3
used by RESRAD a Parameter Input 3....Default 3 (If different from user input) a Name 2 3.000E+04 1.OOOE+04 AREA 2 2.670E+00 2.000E+00 THICKO ed 20.O000+0 0.OOOE+00 I SUBMFRACT 2 1.950E+02 1.000E+02 LCZPAQ 2.500E+01 3.000E+01 BROL SO.O00E+0O0 O.000E+00 TI I1.0OOE+00 1.000E+00 3 T( 2) 3.000E+00 I 3.000E+O0 T( 3)
S1.O00E+01 I.O00E+01I T( 4)
S3.O001E+01 I 3.O00E+01 T(
5) 1.OOOE+02 a 1.000E+02 T( 6) 3.OOOE+02 3.O000E+02 T( 7) 1.OOE+03 I1.O00E+03 T(
8) not used 0.000E+00 2--
T( 9) not used OaO.00E+O0 a--
T(10)
Cs-137 I.OO0E+00 2 0O000E+00 2--
Sl(l)
Cs-137 not used O.o00E+Oo WI( 1) 0.001E+00 a 0O001E+00 2-a COVERO not used a 1.500E+00 DENSCV not used 1.O00E-03 VCV 1.564E+00 1.500E+00 a--
DENSCZ a 2.200E-03 1.O00E-03 a VCZ 4.100E-01 a 4.000E-01 2-a TPCZ 3 9.500E-02 3 2.OOOE-01 a--
FCCZ (m/yr)
I 3.900E+00 1.OOOE+01 a-a HCCZ 5.600E+00 2 5.300E+00 a-a BCZ 3.040E+00 2.OOOE+00 a-WIND not used 8.000E+00 a-HUMID a 6.250E-01 O5.OQE-01 EVAPTR 9.100E-01 I.O001E+00 2-a PRECIP 5.600E-01 2.00OE-01 RI overhead a overhead IDITCH 5.000E-01 a 2.OOOE-01 RUNOFF (m**2) 2.520E+07 1.OOOE+06 WAREA 1.000E-03 1.O00OE-03 EPS 1.510E+00 1.500E+00 DENSAQ 4.300E-01 4.OOOE-01 3 TPSZ 3 3.420E-01 I 2.000E-01 EPSZ 3 8.800E-02 a 2.000E-01 FCSZ AAA r
BARTLETT Page 67
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R014 S
Saturated zone hydraulic conductivity (m/yr) a 2.880E+01 ' 1.OOOE+02 HCSZ R014 saturated zone hydraulic gradient a 2.OOOE-03 a 2.000E-02 HGWT R014
- Saturated zone b parameter S 7.100E+00 a 5.300E+00 a-a BSZ R014 water table drop rate (m/yr) a 1.OOOE-03 a 1.000E-03 a-a VWT R014 a well pump intake depth (m below water table) a 1.OOOE+01 a 1.000E+01 a-a DWIBWT R014 a Model: Nondispersion (ND) or Mass-Balance (MB) a ND a ND MODEL R014 a well pumping rate (m**3/yr) a 1.573E+03 a 2.500E+02 UW
- IRESRAD, version 6.5 T1 Limit = 30 days 11/27/2011. 09:09 Page 4
summary : HB soil DCGLCs137 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\CS137 DCGL\\HB SOIL DCGL-CS137.RAD Site-Specific Parameter Summary (continued) 0 a
a User a
a used by RESRAD a
Parameter Menu a Parameter a.Input.
Default a.(If diffe rent rom user input) a Name R015 Number of unsaturated zone strata 1
3 1 i aS R015 Unsat. zone 1, thickness (m) 4.040E+00 a 4.OO0E+00 a-a H(1)
R015 Unsat. zone 1, soil density (g/cm**3) a 1.564E+00 a 1.500E+00 a-- DENSUZ(1)
R015 Unsat. zone 1, total porosity a 4.100E-01 a 4.OOOE-01 a TPUZ(1)
R015 Unsat. zone 1, effective porosity a 3.150E-01 a 2.OOOE-01 a EPUZ(1)
R01S Unsat. zone 1, field capacity 9.500E-02 2.000E-01 a FCUZ(1)
R015 3 Unsat. zone 1, soil-specific b parameter 5.600E+00 5.300E+00 a-a BUZ(1)
R015 Unsat. zone 1, hydraulic conductivity (m/yr) 3.900E+00 1.0OOE+O1 a aCUZ(1)
R016 Distribution coefficients for Cs-137 a
a R016 a Contaminated zone (cm**3/g) a 4.460E+02 a 4.600E+03 a--
DCNUCC( 1)
R016 a Unsaturated zone 1 (cm**3/g) a 4.460E+02 a 4.600E+03 a--
DCNUCU( 1,1)
R016 a Saturated zone (cm**3/g) 4.460E+02 4.600E+03 DCNUCS( 1)
R016 Leach rate (/yr) a O.OOOE+00 a O.O0OE+OO a
2.043E-04 ALEACH( 1)
R016 Solubility constant 0.O0OE+0O O.00OE+0O not used SOLUBK( 1)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 a-a INHALR R017 Mass loading for inhalation (g/m**3) a 1.000E-04 a 1.OOOE-04 MLINH R017 Exposure duration a 3.OOOE+01 a 3.OOOE+01 ED R017 a Shielding factor, inhalation a 5.500E-01 a 4.000E-01 SHF3 R017 Shielding factor, external gamma a 3.980E-01 a 7.000E-01 a-a SHF1 ROl7 Fraction of time spent indoors a 6.571E-01 aS.OO0E-01 a FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 a 2.50OE-01 FOTD R017 Shape factor flag, external gamma 1.000E+00 a 1.OOOE+00 a
>0 shows circular AREA.
a FS R017 Radii of shape factor array (used if FS = -1):
a a
a)
R017 Outer annular radius (m),
ring i
a not used a.000E+01 a-a RADSIAFE(1)
R017 a Outer annular radius (m),
ring 2
a not used a 7.071E+01 aRADSHAPE(
2)
R017 a Outer annular radius (m),
ring 3:
not used a O.OOOE+00 RADSHAPE(
3)
R017 Outer annular radius (m),
ring 4
a not used a O.OOOE+00 aADSHAPE(
4)
R017 Outer annular radius (m),
ring 5
a not used a O.OO0E+00 RADSHAPE(
5)
R017 Outer annular radius (m),
ring 6:
not used a 0.OOOE+0 RADSHAPE(
6)
R017 Outer annular radius (m),
ring 7
a not used a 0.OOOE+0 RAD_SHAPE( 7)
R017 a Outer annular radius (m),
ring 8:
not used a O.OOOE+00 RADSHAPE( 8)
RO17 Outer annular radius (m),
ring 9:
not used a O.OOOE+0O RAD3_.SI-SHAPE(
9)
R017 Outer annular radius (m) ring 10:
not used a 0.000E+00 RADSNAPE(10)
R017 a Outer annular radius (m),
ring 11:
not used a 0.000E+00 RADSHAPE(11)
R017 a Outer annular radius (m),
ring 12:
not used 3 O.OOOE+00 RADSHAPE(12)
- 1RESRAD, version 6.5 Tn Limit = 30 days 11/27/2011 09:09 Page 5
Summary : KB soil DCGLCs137 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\CS137 DCGL\\HB SOIL DCGL_CS137.RAD Site-Specif 0
menu aParamete R017 Fractions of annular areas within AREA:
ROl7 Ring 1
R017 Ring 2
R017 Ring 3
R017 Ring 4
R017 Ring 5
R017 Ring 6
R017 Ring 7
R017 a Ring 8
ROl7 a Ring 9
ROl7 Ring 10 R017 a Ring 11 R017 a Ring 12 R018 a Fruits, vegetables and grain consumption (kg/y R018 Leafy vegetable consumption (kg/yr)
R018 Milk consumption (L/yr)
R018 a Meat and poultry consumption Ckg/yr)
R018 3 Fish consumption (kg/yr)
R018 a Other seafood consumption (kg/yr)
R018 a Soil ingestion rate (g/yr)
R018 a Drinking water intake (L/yr)
R018 a Contamination fraction of drinking water R018 a Contamination fraction of household water R018 a Contamination fraction of livestock water R018 a Contamination fraction of irrigation water ROl8 a Contamination fraction of aquatic food R018 a Contamination fraction of plant food R018 a Contamination fraction of meat R018 Contamination fraction of milk R019 Livestock fodder intake for meat (kg/day)
R019 Livestock fodder intake for milk (kg/day)
R019 Livestock water intake for meat (L/day)
R019 a Livestock water intake for milk (L/day)
R019 3 Livestock soil intake (kg/day)
R019 Mass loading for foliar deposition (g/m**3)
R019 Depth of soil mixing layer (m)
R019 Depth of roots jm)
R019 Drinking water fraction from ground water RO19 Househol d water fraction from ground water R019 a Livestock water fraction from ground water R019 Irrigation fraction from ground water R19B wet weight crop yield for Non-Leafy (kg/m**2)
R19B wet weight crop yield for Leafy (kg/m-*2)
R198 wet weight crop yield for Fodder (kg/m**2)
RlB Growing Season for Non-Leafy (years)
R19B Growing Season for Leafy (years)
C BARTLETT ic Parameter Summary (continued) a User a
a... Input aDefault a(if a not used a 1.oOOE+00 a not used a 2.732E-01 a not used a O.OOOE+O0 not used a O.OOOE+0O not used
' O.OOOE+00 a a not used a O.OOOE+O0 a not used a O.000E+00 a not used a 0.OOOE+OO a a not used 3 O.OOOE+00 not used a O.OOOE+00 not used a O.0OOE+OO a not used a O.OO0E+O0 a
yr) 1.120E+02 a 1.600E+02 a
2.140E+01 a 1.400E+01 a a 2.330E+02 3 9.200E+01 3 a 6.510E+01 a 6.300E+01 a a 2.060E+01 a 5.400E+00 a a 9.OOOE-01
- 9.OOOE-01 a a 1.826E+01 a 3.650E+01 3 4.785E+02 a 5.100E+02 a 1.OOOE+00 ' 1.OO0E+0O a a not used a 1.0OOE+00 a 1.O0OE+00 a 1.OOOE+0O a 1.OO0E+O0 ' 1.OOOE+Oa a 1.000E+00 a 5.OOOE-01 a 1.OO0E+OO '-I 1.OOOE+00 '-1 2.710E+01 a 6.800E+01 6.320E+01 a 5.500E+01 a 5.060E+O1 a 5.000E+01 6.OOOE+01 a 1.600E+02 5.OOOE-01 5.OOOE-Ol 4.OOOE-04 a 1.OOOE-04 a 2.300E-01 a 1.500E-01 a 1.220E+00 a 9.000E-_01 1.0OOE+00 ' 1.OOOE+00 a not used a 1.OOOE+00 1.000E+00 a 1.OOOE+00 a S1.OOOE+00 1.000E+00 a 1.750E+00 a 7.OOOE-O1 a a 2.889E+00 a 1.500E+00 a
- 1,887E+00 a 1.100E+00 '
2.460E-01 a 1.700E-01 a a
n*Or-ni a l;On*F-Ai used by RESRAD a
Parameter different from user input) a Name a-FRACA(
1) a-FRACA(
2) a FRACA(
3) a-FRACA(
4)
- -FRACAC 5) a-FRACA(
6) a-FRACA(
7) a-FRACA(
8) a-FRACA(
9) a-FRACA(10) a-FRACA(II) a-FRACA(12) a-DIET(l) a DIET(2) a-DIET(3) a DIET(4)
DIET(S) a DIE-r(6) a-SOIL
-DWI a-FDW a-FHHW a-FLW FIRW a-FR9 a-FPLANT a FMEAT a FMILK a LFI5 a-LFI6 aLw15 a LwI6 a-LSI a-MLFD a-DM DROOT
-3 FGWHH a-FGWLW
- -FGWIR a-YV(1) aYV(2)
-Yv(3) a-TE(1) a-TP Q)
Page 68
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R19B 3 Growing Season for Fodder (years)
- 8.200E-02 I 8.OOOE-02 IRESRAD, version 6.5 Tc Limit = 30 days 11/27/2011 09:09 Page 6
Summary : HB soil DCGLCS137 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\CS137 DCGL\\HB SOIL DCGLCS137.RAD Site-Specific Parameter Summary (continued) 0 3
3 User 3
' TE(3) menu R19B R19B R19B R19B R19B R19B R19B R19B R19B R19B C14 C14 C14 C14 C14 C14 C14 C14 C14 STOR STOR STOR STOR STOR STOR STOR STOR STOR STOw R02 1 R02 1 R021 R021 R02 1 R02 1 R021 R021 R02 1 R021 R021 R021 R021 R02 1 R021 R02 1 R021 3
Parameter Translocation Factor for Non-Leafy Translocation Factor for Leafy Translocation Factor for Fodder Dry Foliar Interception Fraction for Non-Leafy Dry Foliar Interception Fraction for Leafy Dry Foliar Interception Fraction for Fodder wet Foliar Interception Fraction for Non-Leafy wet Foliar Interception Fraction for Leafy wet Foliar Interception Fraction for Fodder weathering Removal Constant for vegetation C-12 concentration in water (g/cm**3)
C-12 concentration in contaminated soil (g/g)
Fraction of vegetation carbon from soil Fraction of vegetation carbon from air C-14 evasion layer thickness in soil (m)
C-14 evasion flux rate from soil (1/sec)
C-12 evasion flux rate from soil (1/sec)
Fraction of grain in beef cattle feed Fraction of grain in milk cow feed Storage times of contaminated foodstuffs (days):
Fruits, non-leafy vegetables, and grain Leafy vegetables Milk Meat and poultry Fish Crustacea and mollusks well water Surface water Livestock fodder Thickness of building foundation (m)
Bulk density of building foundation (g/cm*-3)
Total porosity of the cover material Total porosity of the building foundation volumetric water content of the cover material volumetric water content of the foundation Diffusion coefficient for radon gas (m/sec):
in cover material in foundation material in contaminated zone soil Radon vertical dimension of mixing (m)
Average building air exchange rate (1/hr)
Height of the building (room)
Wm)
Building interior area factor Building depth below ground surface (m)
Emanating power of Rn-222 gas Emanating power of Rn-220 gas Inut efalt (if Used by RESRAD Parameter di n
rm userinput).
Name.
AaaAAAAAaAAaAAA~aA~~aAaAAA~aAAAAaAAAAAAAAAAAAAAAAA 1.00oE-01 1.000E+00 1.000E+00 3.500E-01 3.500E-01 3.500E-01 3.500E-01 5.800E-01 3.500E-01 3.300E+01 not used not used not used not used not used not used not used not used not used 1.400E+01 1.OOOE+00 1.000E+00 2.000E+01 7.OOOE+00 7.OOOE+00 1.000E+00 1.OOOE+00 4.500E+01 not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used 1.000E-0l 1.000E+00 1.OOOE+O0 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.000E+01 2.000E-OS 3 3.000E-02 I 2.000E-02 9.800E-01 3.000E-01 7.000E-07 1.OOOE-10 8.OOOE-01 2.000E-01 3 1.400E+01 S1.O000E+00 3 l.000E+00 2.OOOE+01 7.OOOE+00 7.OOOE+00 1.000E+00 1.OOOE+00 4.500E+01 1.500E-01 2.400E+00 4.000E-01 1.OOOE-01 5.000E-02 3.000E-02 2.000E-06 3.000E-07 3 2.000E-06 3 2.000E+00
' 5.000E-01 3 2.500E+00 3 O.OOOE+00 3-1.000E+00 3 2.500E-01 3 1.500E-01 TIV(1)
TIV(2)
TIV(3)
RDRY(1)
RDRY(2)
RDRY(3)
RWET(1)
RWET(2)
RWET(3)
WLAM C12WTR C12CZ CSOIL CAIR DMC EVSN REVSN AVFG4 AVFG5 STORT(l) 3 STORT(2) 3 STORT(3)
STORCT(4)
STORT(5)
STORT(6)
STORCT(7)
STORT(8)
STORT(9)
FLOOR1 DENSFL TPCV 3 TPFL 3 PH2OCV Pm2OFL DIFCV DIFFL DIFCZ HMIX 3 REXG 3 HRM 3 FAI DMFL EMANA(1)
EMANA(2)
TITL Number of graphical time points 32 NPTS IRESRAD, Version 6.5 Tx Limit = 30 days 11/27/2011 09:09 Page 7
Summary : HB soil DCGLCS137 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\CS137 DCGL\\HB SOIL DCGLCS137.RAD Site-Specific Parameter Summary (continued) 0 3
1 User used by RESRAD 3 Parameter Menu
.Par..................................
P ameter input Defaul.t1(......
f
(
..differ.n.from..user... input) 3 Name TITL 3 Maximum number of integration points for dose 17 3---
3 LYMAX TITL 3 maximum number of integration points for risk 1
KYMAX summary of Pathway Selections
.Pathway User Selection 1-- external gamma active 2
inhalation (w/o radon) 3 active 3 --
plant ingestion active 4--
meat ingestion active 5 milk ingestion active 6
aquatic foods active 7
drinking water active 8 -- soil ingestion active 9 --
radon suppressed Find peak pathway doses active 1RESRAD, Version 6.5 Tl Limit = 30 days 11/27/2011 09:09 Page 8
Summary : HB soil DCGL-CS137 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\CS137 DCGL\\HB SOIL DCGL.CS137.RAD Contaminated Zone Dimensions Initial Soil Concentrations-pti/g Area:
30000.00 square meters Cs-137 1.OOOE+00 Thickness:
2.67 meters Cover Depth:
0.00 meters 1RESRAD, Version 6.5 Tl Limit = 30 days 11/27/2011 09:09 Page 1
probabilistic results summary : HB soil DCGL_Cs137 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\CS137 DCGL\\HB SOIL DCGL.CS137.RAD Table of Contents Part VI: Uncer t ainty Analisis ORESRAD Uncertainty Analysis Results Probabilistic Input..
2 Total Dose...
3
-BARTLETT Page 69
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Total Risk............................................
4 Dose vs Pathway:
Ground External...................
5 Dose vs Pathway:
Inhalation (w/o Radon) 6 Dose vs Pathway:
Radon (water Ind.)
7 Dose vs Pathway:
Plant (water Ind.)................
8 Dose vs Pathway:
Meat (Water Ind.)................
9 Dose vs Pathway:
Milk (water Ind.)
10 Dose vs Pathway:
Soil Ingestion.....................
11 Dose vs Pathway:
water Ingestion....................
12 Dose vs Pathway:
Fish Ingestion.....
13 Dose vs Pathway:
Radon (water Dep.)
14 Dose vs Pathway:
Plant (water Dep.).................
15 Dose vs Pathway:
Meat (water Dep.)................
16 Dose vs Pathway:
Milk (water Dep.).................
17 Cumulative Probability Summary.......................
18 Summary of dose at graphical times, reptition 1...
19 Peak of the mean dose at graphical times.............
20 Correlation and Regression coefficients (if any).....
21 IRESRAD, Version 6.5 T< Limit = 30 days 11/27/2011 09:09 Page 2
Probabilistic results summary : HB soil DCGLCS137 File : C:\\RESRADIFAMILY\\RESRAD\\6.5\\USERFILES\\CS137 DCGL\\HB SOIL DCGLCS137.RAD Probabilistic Input ONumber of Sample Runs: 2000 Number 1
2 3
4 5
6 7
8 9
10 11 12 13 14 15 16 17 18 19 20
.00003 21 22 23 24 25 26 27 28 29 Milt' Name Distribution Parameters DENSCZ BOUNDED NORMAL 1.5635
.2385
.827 2.3 TPCZ BOUNDED NORMAL
.41
.09
.1319
.6881 HCCZ BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 BCZ BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 EVAPTR UNIFORM
.5
.75 RI UNIFORM
.36
.76 DENSAQ BOUNDED NORMAL 1.5105
.1855
.937 2.084 TPSZ BOUNDED NORMAL
.43
.0699
.214
.646 EPSZ BOUNDED NORMAL
.342
.0705
.124
.56 HCSZ BOUNDED LOGNORMAL-N.362 1.59
.0106 195 BSZ BOUNDED LOGNORMAL-N 1.96
.265 3.02 15.5 DWIBWT TRIANGULAR 6
10 30 U1W UNIFORM 1173 1973 H(1)
UNIFORM 0
8.08 DENSUZ(1)
BOUNDED NORMAL 1.5635
.2385
.827 2.3 TPUZ(1)
BOUNDED NORMAL
.41
.09
.1319
.6881 EPUZ(1)
BOUNDED NORMAL
.315
.0905
.0349
.594 HCUZ(1)
BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 BUZ(1)
BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 MLINH CONTINUOUS LINEAR 8
0 0
.000008
.8119
.00004
.9495
.00006
.9937
.000076
.9983
.0001 1
SHF3 UNIFORM
.15
.95 DM TRIANGULAR 0
.15
.6 YV(1)
TRUNCATED LOGNORMAL-N.56
.48
.001
.999 WLAM TRIANGULAR 5.1 18 84 RWET(2)
TRIANGULAR
.06
.67
.95 DCACTC(1)
TRUNCATED LOGNORMAL-N 6.1 2.33
.001
.999 DCACTUI(1)
TRUNCATED LOGNORMAL-N 6.1 2.33
.001
.999 DCACTS(1)
TRUNCATED LOGNORMAL-N 6.1 2.33
.001
.999 BBIO(55,1)
LOGNORMAL-N 7.6
.7 ffftftifftifffifffttif tIfIffiftfffffffillitt l~~itfiitttttttifflifi ttttttfii fiftfiftt 0151
.000016
.1365 IRESRAD, version 6.5 Tn Limit = 30 days 11/27/2011 09:09 Page 20 Probabilistic results summary : HB soil DCGL-Cs137 File : C:\\RESRADOFAMILY\\RESRAD\\6.5\\USERFILES\\Cs137 DCGL\\HB SOIL DCGLCS137.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1
0.OOOE+00 3.151E+00 (f BARTLETT Page 70
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Eu-152 Results:
IRESRAD, Version 6.S Tm Limit = 30 days 11/27/2011 09:29 Page 1
Summary HB soil DCGLEU-152 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\EU152 DCGL\\HB SOIL DCGLEUI52.RAD Table of Contents Part I:
Mixture Sums and Sinole Radionuclide Guidelines tfittttftttIttttiIttIttttftIIt tIffflifi11ItIlIfllIIIff Dose Conversion Factor (and Related) Parameter Summary...
2 site-Specific Parameter Summary............................
3 Summary of Pathway Selections..............................
7 contaminated Zone and Total Dose Summary...................
8 Total Dose Components Time = 0.OOOE+0O....................................
9 Time = 1.OOOE+00.....................................
10 Time = 3.OO E+O0...........................
11 Time = 1.000E+01.....................................
12 Time = 3.OOOE+01.....................................
13 Time = 1.O0OE+02..
14 Time = 3.OO E+02....................................
15 Time = 1.000E+03....................................
16 Dose/Source Ratios Summed Over All Pathways.................
17 Single Radionuclide Soil Guidelines.......................
17 Dose Per Nuclide Summed Over All Pathways.................
18 Soil Concentration Per Nuclide...........................
18 IRESRAD, Version 6.5 T<' Limit = 30 days 11/27/2011 09:29 Page 2
Summary : HB soil DCGLEu-152 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\EU152 DCGL\\HB SOIL DCGLEU152.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: HB DCGLs Plus FGR 12 & FGR 11 0
a Current I
Base Menu P
et v
Ca Parameter Name A-I DCF'S for external ground radiation, (mrem/yr)/(pCi/g)
A-1 Eu-152 (Source:
FGR 12) 7.006E+00 7.006E+00 DCF1(
1)
A-i Gd-152 (Source:
FGR 12)
O.OD0E+00 O.000E+O0 DCFI(
2)
B-1 Dose conversion factors for inhalation, mrem/pCi:
a B-i Eu-152 2.210E-04 2.210E-04 DCF2(
1)
B-1 Gd-152 2.430E-01 2.430E-01 DCF2(
3)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 EU-152 6.480E-06 a 6.480E-06 DCF3(
1)
D-1 ad-152 1.610E-04 I 1.610E-04 DCF3(
3)
D-34 Food transfer factors:
D-34 EU-152
, plant/soil concentration ratio, dimensionless a 2.500E-03 a 2.500E-03 RTF(
1,1)
D-34 Eu-I52 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 2.0OOE-03 a 2.OOOE-03 RTF(
1,2)
D-34 EU-152 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 5.000E-05 a S.000E-05 RTF(
1,3)
D-34 D-34 Gd-I52
, plant/soil concentration ratio, dimensionless 2.500E-03 2.500E-03 RTF(
3,1)
D-34 Gd-1S2 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) a 2.000E-03 a 2.OOOE-03 RTF(
3,2) o-34 Gd-152 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.OOOE-05 2.D0OE-05 RTF(
3,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 EU-152
, fish 5.OOOE+Oa 5.000E+01 BIOFAC(
1,1)
D-5 EU-152
, crustacea and mollusks 1.OOOE+03 1.0OOE+03 BIOFAC(
1,2)
D-5 D-5 Gd-152
, fish 2.500E+01 2.500E+01 BIOFAC(
3,1)
D-5 Gd-i52
, crustacea and mollusks a i.OOE+03 I.OOOE+03 BIOFAC(
3 2)
- For DCFI(xxx) only, factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Default.Lib w/o Associate Nuclide contributions.
1RESRAD, version 6.5 Ta' Limit = 30 days 11/27/2011 09:29 Page 3
Summary : HB soil DCGL.Eu-152 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\Eul52 DCGL\\HB SOIL DCGL.EU152.RAD o
3 Menu a Site-Specific Parameter Summary User a
a used by RESRAD 3
Parameter S.Input a Default a (If different from user input)
Name Parameter......
A AAAAAAAAAAAAAAAAAAAAAAAAAAA ROll a Area of contaminated zone (m**2)
ROll a Thickness of contaminated zone (m)
R011 a Fraction of contamination that is submerged R011 a Length parallel to aquifer flow (m)
Roil a Basic radiation dose limit (mrem/yr)
R011. Time since placement of material (yr)
Roil a Times for calculations (yr)
R011 a Times for calculations (yr)
Roll a Times for calculations (yr)
R011 Times for calculations (yr)
Roil a Times for calculations (yr)
Roll a Times for calculations (yr)
Roll Times for calculations (yr)
R011 a Times for calculations (yr)
Roil a Times for calculations (yr)
R012 a Initial principal radionuclide (pCi/g):
Eu R012 a Concentration in groundwater (pCi/L):
Eu.
R013 Cover depth (m)
R013 a Density of cover material (g/cm**3)
R013 a Cover depth erosion rate (m/yr)
R013 a Density of contaminated zone (g/cm**3)
R013 a Contaminated zone erosion rate (m/yr)
R013 a Contaminated zone total porosity R013 a Contaminated zone field capacity R013 a Contaminated zone hydraulic conductivity (mi R013 a Contaminated zone b parameter R013 a Average annual wind speed (m/sec)
R013 a Humidity in air (g/m**3)
R013 a Evapotranspiration coefficient R013 a Precipitation (m/yr)
R013 a Irrigation (m/yr)
-152
-152
/yr) a 3.OOOE+04 1.OOOE+04 1.830E+00 2.OOOE+O0 O.OOOE+O0 a.00E+0O 1.950E+02 a.DOOE+02 2.500E+01 3.DOOE+01 O.OOE+0O a.00OE+÷0 a.OOOE+D0 I.OOE+0O 3.000E+00 3.DOOE+DO 1.OooE+0I I.O0E+Oia 3.000E+0i 3.OOE+OIa a.O00E+02 a.OOOE+02 3.OOOE+02 3.OOOE+02 a.OOOE+03 i.ODOE+03 not used O.O00E+0O not used O.OOOE+00 1.OOOE+O0 O.O00+ODa not used O.OOOE+Oa 0.O005E+0 O.OOOE+0a a not used a 1.500E+00 a not used a 1.000E-03 a 1.564E+00 a 1.500E+00 a a 2.200E-03 a 1.000E-03 a a 4.100E-01 a 4.OOOE-01 a 9.50OE-02 a 2.OOE-01 a 3.900E+Oo a 1.oooE+01 a a 5.600E+00 5.300E+00 a a 3.040E+00 2.OOE+00 a not used 8.OOOE+00 a 6.250E-01 a 5.000E-01 a a 9.100E-01 a 1.O00E+0D a
a 5.600E-01 a 2.DOOE-01 a AREA THICKO SUBMFRACT LCZPAQ BRDL TI T( 2)
T( 3) a T( 4)
T(
5)
T( 6)
T(
7)
T(
8)
T(
9)
T(10)
S 1(1) a wl( 1)
COVERO DENSCV VCV DENSCZ VCZ TPCZ FCCZ HCCZ BCZ WIND HUMID EVAPTR PRECIP RI t
BARTLETT Page 71
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R013 Irrigation mode overhead overhead a
RO13 Runoff coefficient 5.000E-01 2.OOOE-01 RO13 watershed area for nearby stream or pond (m**2) 2.520E+07 1.OOOE+06 R013 Accuracy for water/soil computations 1.OOOE-03 a t.OOE-03 R014 Density of saturated zone (g/cm**3)
I 1.S1OE+O0 1.5O0E+00 R014 a Saturated zone total porosity 4.300E-01 a 4.OOOE-01 R014 a Saturated zone effective porosity a 3.420E-01 a 2.OOOE-01 R014 a Saturated zone field capacity 8.00E-02 a 2.OOOE-01 R014 Saturated zone hydraulic conductivity (m/yr) 2.880E+01 a 1.000E+02 R014 a Saturated zone hydraulic gradient a 2.OOOE-03 I 2.OOOE-02 R014 Saturated zone b parameter a 7.100E+00 a 5.300E+00 R014 water table drop rate (m/yr) 1.OOOE-03 I 1.OOOE-03 R014 well pump intake depth (m below water table) 1.000E+01 a 1.oooE+01 R014 Model: Nondispersion (ND) or Mass-Balance (MB)
ND a ND R014 a well pumping rate (m**3/yr) 1.573E+03 a 2.500E+02 IRESRAD, version 6.5 T. Limit = 30 days 11/27/2011 09:29 Page 4
Summary : HB soil DCGLEu-152 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\EU152 DCGL\\HB SOIL DCGL_EU152.RAD a IDITCH a RUNOFF a WAREA EPS DENSAQ a TPSZ EPSZ FCSZ HCSZ a HGWT a BSZ a owsm-r DWaBW'E MODEL Uw Site-Specif Menu a Parametr ROS a Number of unsaturated zone strata ROtS a Unsat. zone 1, thickness (m)
R01s a Unsat. zone 1, soil density (g/cm**3)
R015 a Unsat. zone 1, total porosity RO15 a unsat. zone 1, effective porosity R015 a Unsat. zone 1, field capacity R015 a Unsat. zone 1, soil-specific b parameter R015 a Unsat. zone 1, hydraulic conductivity (m/yr)
R016 Distribution coefficients for Eu-15S R016 Contaminated zone (cm**3/g)
R016 Unsaturated zone 1 (cm**3/g)
R016 Saturated zone (cm**3/g)
R016 Leach rate (/yr)
R016 Solubility constant R016 Distribution coefficients for daughter Gd-152 ROt1 Contaminated zone (cm**3/g)
R016 Unsaturated zone 1 (cm**3/g)
RO16 Saturated zone (cm*a3/g)
R016 Leach rate (/yr)
R016 solubility constant R017 Inhalation rate Cm**3/yr)
R017 a Mass loading for inhalation (g/m**3)
R01 a Exposure duration ROll a Shielding factor, inhalation R017 a Shielding factor, external gamma ROll a Fraction of time spent indoors R017 a Fraction of time spent outdoors (on site)
RO17 a Shape factor flag, external gamma ROl7 a Radii of shape factor array (used if FS = -1):
R017 a Outer annul ar radius (m),
ring 1:
R017 a Outer annular radius (m),
ring 2:
R017 Outer annular radius (m),
ring 3:
ROl7 a outer annular radius (m),
ring 4:
R017 a Outer annular radius (m),
ring 5:
R017 Outer annular radius (m),
ring 6:
ROl7 Outer annular radius (m),
ring 7:
R017 Outer annular radius (m),
ring 8:
R017 Outer annular radius (m),
ring 9:
R017 Outer annular radius (m),
ring 10:
R017 a Outer annular radius (m) ring 11:
R017 Outer annular radius (m),
ring 12:
ic Parameter Summary (continued) a User a
used by RESRAD a
Parameter S
Input..
Default a(if different.from user input)
Name a 4.040E+00 I 4.OOOE+00 a 1.564E+00 3 1.SO50E+00 a 4.100E-01 3 4.OOOE-01 a 3.15oE-01 a 2.OOOE-01 a a 9.500E-02 a 2.OOOE-01 S5.600E+00 a 5.300E+00 3.900E+00 a 1.OOOE+01 3
a 7.220E+03 a-1.oooE+OO a 8.250E+02 a-t.OOOE+OO 8.250E+02 a-1.0O0E+00 O.000E+OO aO.OOOEO0a O.OOE+00 aO.OOOE+O0 3
a 8.250E+02 a-1.000E+003 a 8.250E+02 3-I.00aE+0 a 8.250E+02 3-1.aOOE+00 a
+O.OOOE+O O.0E4O0 a O.OOOE+0a O.OOOE+O0 a
a 8.400E+03 a 8.400E+03 a 1.OOOE-04 1.OOOE-04 a 3.OOOE+O1 3.oOE+01 a 5.50OE-01 a 4.OOOE-01 3.980E-01 7.OOOE-01 6.571E-01 5.o000E-01 1.181E-01 2.500E-01 1.OOOE+OO a 1.O00E+OO not used a 5.OOOE+01 a not used a 7.071E+01 a not used a O.O0OE+O0 not used O.OOE+O0 not used aO.OOOE+00 not used a O.O00E+0o a a not used a O.OOOE+00 a a not used a O.0O0E+OO a a not used a O.OOOE+-OO a not used a O.OOOE+OO a a not used a O.OOOE+OO a
a not used a O.O00E+00 a 1.8442E-05 not used 1.612E-04 not used
>0 shows circular AREA.
NS H(1)
DENSUZ(1)
TPUZ(1)
EPUZ(1)
FCUZ(1) a BUZ(1)
- HCUZ(1) a DCNUCC(
1) a DCNUCU( 1,1) a DCNUCS( 1) a ALEACH(
1) a SOLUBK( 1) a DCNUCC(
3) a DCNUCU( 3,1) a DCNUCS( 3)
ALEACH(
3) a SOLUBK(
3)
INHALR MLINH a ED a SHF3 a SHF1 a FIND FOTD FS RAD.SHAPE(
1) a BADSHAPE(
2)
' RAD.SHAPE(
3) a RADSHAPE(
4)
RADSHAPE(
5)
RADSHAPE(
6) aADSHAPE(
7) aADSHAPE(
8)
RADSHAPE(
9) a RADSHAPE(10) aRADSHAPE(11)
RADSHAPE(12) tRESRAD, Version 6.5 Tx Limit = 30 days 11/27/2011 09:29 Page 5
Summary : HB soil DCGLEU-152 File
- C:\\RESRAD.FAMILY\\RESRAD\\6.S\\USERFILES\\EU152 DCGL\\HB SOIL DCGLEUI52.RAD Site-Specific Parameter Summary (continued) a 3
3 User 3
3 used by RESRAD a
Parameter menu a Pa!rametr Input a
Default a (if different from user input)
Name R017 a Fractions of annular areas within AREA:
a ROl Ia Ring 1
a not used a t.OOOE+O0 a-a FRACA( 1)
R017 a Ring 2
a not used a 2.732E-01 FRACA( 2)
ROl Ia Ring 3
a not used a O.OOOE+O0 FRACA( 3)
ROl7 Ring 4
a not used a O.OOOE+O0 FRAcA( 4)
R017 Ring 5
a not used a O.O00E+-OO FRACA( 5)
R017 a Ring 6
a not used a O.OOOE+O0 FRACA( 6)
R017 a Ring 7
a not used a O.OOOE+O0 FRACA( 7)
R017 a Ring 8
a not used o.OOOE+03 FRACAC 8)
R017 Ring 9
not used O.OOOE+O0 FRACAC 9)
R017 Ring t0 not used O.OOOE+O0 FRACA(IO)
R017 a Ring 11 a not used a O.OOOE+O0 a-a FRACA(11)
ROl Ia Ring 12 a not used a O.OOOE+O0 FRACA(12)
R018 a Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 a-a DIET(l)
RO18 a Leafy vegetable consumotion (kg/yr) 2.140E+01 1.400E+Ol a-a DIET(2)
ROt8 Milk consumption (L/yr) 2.330E+02 9.200E+01 a-a DIET(3)
R018 Meat and poultry consumption (kg/yr) a 6.510E+01 a 6.300E+01 DIET(4)
ROt8 a Fish consumption (kg/yr) 2.060E+01 a 5.400E+O0 DIET(S)
RO1 Ia Other seafood consumption (kg/yr) 9.OOOE-Ol a 9.OOE-OI DIET(6)
R018 a Soil ingestion rate (g/yr) 1.826E+01 a 3.650E+01 SOIL ROt8 a Drinking water intake (L/yr) 4.785E+02 a 5.100E+02 DWI R018 a Contamination fraction of drinking water 1.000E+O0 1.00OE+O0 a-a FDW R018 a Contamination fraction of household water not used 1.0OOE-E+00 a FHIW R018 a Contamination fraction of livestock water 1.OOOE+OO 1.OO0E+OO a FLW ROl8 a Contamination fraction of irrigation water 1.000E+OO 1.000E-OO a-a FIRW ROt8 a Contamination fraction of aquatic food 1.OOOE+OO a 5.00E-01 FR9 RO8 a Contamination fraction of plant food 1.000E+OO a-1 FPLANT R018 a Contamination fraction of meat a t.OOE+00 a-1 a-a FMEAT ROt8 a Contamination fraction of milk a 1.OOOE+0O a-1 a-a FMILK ROI9 a Livestock fodder intake for meat (kg/day) a 2.710E+01 a 6.800E+01 LFI5 ROI9 a Livestock fodder intake for milk (kg/day) 6.320E+01 a 5.500E+01 LF16 W)ARTLETT Page 72
Bartleft Engineering ENG-HB-003 Humboldt Say Soil DCGLs Rev. 0 R019 Livestock water intake for meat (L/day) 5.060E.01 5.000E+01 LWIS ROI9 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 LWI6 intak l.OOOE-OI 3.0EO 3LSI R019 3 Livestock soil intake (kg/day)5.
E-01 R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.00OE-04 MLFD RO19 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 DM RO9 Depth of roots (m) 2.150E+00 9.000E-01 DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 FGWDW RO9 Household water fraction from ground water not used 1.000E+00 FGWHH RO19 Livestock water fraction from ground water 1.000E+00 3 1.000E+00 FGWLW R019 Irrigation fraction from ground water 1.000E+0O 1.00E+00---
FWR R19B Wet weight crop yield for Non-Leafy Ckg/m**2) 1.750E+00 7.OOOE-01 Yv(1)
R19B wet weight crop yield for Leafy (kg/m' 2) 2.889E+00 1.500E+00 V(2)
R19B wet weight crop yield for Fodder (kg/m 3 *2) 1.887E+00 1.100E+00 Yv(3)
Ri9e Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 TE(1)
R19B Growing Season for Leafy (years) 3 1.230E-01 2.500E-01 TE(2)
R19i Growing Season for Fodder (years) 8.200E-02 8.000E-02 TE(3)
- 1RESRAD, Version 6.5 T1 Limit = 30 days 11/27/2011 09:29 Page 6
Summary HB soil DCGLEU-152 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\EUl5 2 DCGL\\HB SOIL DCGLEU1S2.RAD site-Specific Parameter Summary (continued) 0 User 3
3 used by RESRAD 3 Parameter Menu 3 Parameter Input 3
Default 3 (If different from user input)
Name P
R19B 3 Translocation Factor for Non-Leafy 1.00OE-01 1.OOOE-01 TIV(1)
Rl9B 3 Translocation Factor for Leafy 1.O00E+00 1.O00E+00 TIVC2)
Ri9B Translocation Factor for Fodder 1.OOOE+00 1.000E+00 TIV(3)
R19B 3 Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.50OE-01 RDRY(2)
R193 Dry Foiar Interception Fraction for Fodder 3.500O-01 2.500E-01 RDRY(3)
R19B wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 RWET(1)
R19B wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 RWET(2)
R19B wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 RWET(3)
Ri9e 3 weathering Removal Constant for vegetation 3.300E+01 2.000E+01 WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 cl2cz C14 3 Fraction of vegetation carbon from soil not used 2.OOOE-02 CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 CAIR C14 3 C-14 evasion layer thickness in soil (m) not used 3.000E-01 DMC C14 3 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 REVSN C14 Fraction of grain in beef cattle feed not used 8.OOOE-01 AVFG4 C14 Fraction of grain in milk cow feed not used 2.OOOE-01 AVFG5 STOR
' Storage times of contaminated foodstuffs (days):
STOR 3 Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 sTORT)
STOR 3 Leafy vegetables 1.000E+00 1.OOOE+00 STORT(2)
STOR '
Milk I.O00E+O0 I.O00E+O0 3 STORT(3)
STOR 3 Meat and poultry 2.000E+01i 2.000E+01 STORT(4)
STOR Fish 7.000E+00 7.000E+00 STORT(5)
STOR Crustacea and mollusks 7.000E+00 3 7.0005+00 STOR._T(6)
STOR Well water 1.O00E+00 i.O00E+00 STORT(7)
STOR surface water 1.000E+00 1.000E---
STORT(8)
STOR Livestock fodder 4.500E+01 4.500E+01 STOR-T(9)
R021 Thickness of building foundation (m) not used 1.SOOE-01 FLOORi R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 DNSFL R021 Total porosity of the cover material not used 4.OOOE-01 TPCV R021 Total porosity of the building foundation not used 1.000E-01 TPFL R021 volumetric water content of the cover material not used 5.OO0E-02 PH2OCv R021 volumetric water content of the foundation not used 3.000E-02 PH2OFL R021 Diffusion coefficient for radon gas (m/set):
R021 in cover material not used 2.OOOE-06 DIFCV R021 in foundation material not used 3.OOOE-07 DIFFL R021 in contaminated zone soil not used 2.000E-06 DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.0OOE+00 HMIX R021 Average building air exchange rate (1/hr) not used 5.OOOE-01 REXG R021 Height of the building (room)
(m) not used 2.500E+00 HRM R021 Building interior area factor not used O.O00E+00 FAI R021 3 Building depth below ground surface (m) not used
'-1.000E+O0 DMFL R021 ' Emanating power of Rn-222 gas not used I 2.500E-01 EMANA(1)
R021 Emanating power of Rn-220 gas not used 3 1.500E-01 EMANA(2)
TITL Number of graphical time points 32 NPTS 1RESRAD, Version 6.5 T" Limit = 30 days 11/27/2011 09:29 Page 7
Summary : HB soil DCGLEu-152 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\EU15 2 DCGL\\HB SOIL DCGL_EU152.RAD site-Specific Parameter Summary (continued) 0 user 3
used by RESRAD Parameter menu Parameter Input Default (If different from user input) 3 Name kALY A X A A A A TITL Maximum number of integration points for dose 17 LYMAX TITL Maximum number of inte ration points for risk 1 ---
KYf.lAX Summary of Pathway Selections Pathway user Selection 1-- external gamma active 2
inhalation (w/o radon)3 active 3-- plant ingestion active 4
meat ingestion active S
milk ingestion active 6-- aquatic foods active 7
drinking water active 8
soil ingestion active 9 --
radon suppressed Find peak pathway doses active fftItllfitItItliftitltfillffllffiititflilttlfiilffIt IRESRAD, Version 6.5 Tx Limit = 30 days 11/27/2011 09:29 Page 8
Summary : HB soil DCGLEu-152 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\Eul5 2 DCGL\\HB SOIL DCGL_EU152.RAD contaminated Zone Dimensions Initial Soil Concentrations, pCi/g BARTLETT Page 73
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Area:
30000.00 square meters Thickness:
1.83 meters Cover Depth:
0.00 meters Eu-152 1.000E+00
- IRESRAD, Version 6.5 T" Limit = 30 days 11/27/2011 09:29 Page I
Probabilistic results summary : HR soil DCGL-EU-152 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\Eul52 DCGL\\HB SOIL DCGLEU152.RAD Table of Contents Part VI: Uncertainty Analysis ORESRAD Uncertainty Analysis Results Probabilistic Input..
2 Total Dose...
3 Total Risk...
4 Dose vs Pathway:
Ground External...................
5 Dose vs Pathway:
Inhalation (w/o Radon) 6 Dose vs Pathway:
Radon (Water Ind.)................
7 Dose vs Pathway:
Plant (Water Ind.)................
8 Dose vs Pathway:
Meat (Water Ind.)
9 Dose vs Pathway:
Milk (Water Ind.)
10 Dose vs Pathway:
Soil Ingestion.....................
11 Dose vs Pathway:
Water Ingestion....................
12 Dose vs Pathway:
Fish Ingestion.....................
13 Dose vs Pathway:
Radon (Water Dep.).................
14 Dose vs Pathway:
Plant (Water Dep.)
15 Dose vs Pathway:
Meat (Water Dep.).................
16 Dose vs Pathway:
Milk (Water Dep.).................
17 Cumulative Probability Summary.......................
18 summary of dose at graphical times, reptitionI 1.....
19 Peak of the mean dose at graphical times.............
20 Correlation and Regression coefficients (if any)...
21 IRESRAD, Version 6.5 T" Limit = 30 days 11/27/2011 09:29 Page 2
Probabilistic results summary : HB soil DCGLEu-152 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\EU152 DCGL\\HB SOIL DCGLEU152.RAD Probabilistic Input ONumber of sample Runs: 2000 Number 1
2 3
4 6
7 8
9 10 11 12 13 14 15 16 17 18 19 20 21
.00003 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 fi13ff Name THICKO DENSCZ TPCZ HCCZ BCZ EVAPTR RI DENSAQ TPSZ EPSZ HCSZ BSZ DWIBWT UW H(1)
DENSUZ(1)
TPUZ(1)
EPUZ(1)
HCUZ(1)
BUZ(1)
MLINH
.8119
.00004 SHF3 DM DROOT YV(1)
WLAM RWET(2)
DCACTU1(1)
DCACTS(1)
DCACTC(3)
DCACTU1(3)
DCACTS(3)
BRTF(63,1)
BRTF(63,2)
BRTF(63,3)
BBIO(63,1)
BRTF(64,1)
BRTF(64,2)
BRTF(64,3)
BBio(64 1)
Distribution Parameters UNIFORM
.15 3.51 BOUNDED NORMAL 1.5635
.2385
.827 2.3 BOUNDED NORMAL
.41
.09
.1319
.6881 BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 UNIFORM
.5
.75 UNIFORM
.36
.76 BOUNDED NORMAL 1.5105
.1855
.937 2.084 BOUNDED NORMAL
.43
.0699
.214
.646 BOUNDED NORMAL
.342
.0705
.124
.56 BOUNDED LOGNORMAL-N.362 1.59
.0106 195 BOUNDED LOGNORMAL-N 1.96
.265 3.02 15.5 TRIANGULAR 6
10 30 UNIFORM 1173 1973 UNIFORM 0
8.08 BOUNDED NORMAL 1.5635
.2385
.827.
2.3 BOUNDED NORMAL
.41
.09
.1319
.6881 BOUNDED NORMAL
.315
.0905
.0349
.594 BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 CONTINUOUS LINEAR 8
0 0
.000008
.9495
.00006
.9937
.000076
.9983
.0001 1
UNIFORM
.15
.95 TRIANGULAR 0
.15
.6 UNIFORM
.3 4
TRUNCATED LOGNORMAL-N.56
.48
.001
.999 TRIANGULAR 5.1 18 84 TRIANGULAR
.06
.67
.95 TRUNCATED LOGNORMAL-N 6.72 3.22
.001
.999 TRUNCATED LOGNORMAL-N 6.72 3.22
.001
.999 TRUNCATED LOGNORMAL-N 6.72 3.22
.001
.999 TRUNCATED LOGNORMAL-N 6.72 3.22
.001
.999 TRUNCATED LOGNORMAL-N 6.72 3.22
.001
.999 TRUNCATED LOGNORMAL-N -6.21 1.1
.001
.999 TRUNCATED LOGNORMAL-N -6.21 1
.001
.999 TRUNCATED LOGNORMAL-N -9.72
.9
.001
.999 LOGNORMAL-N 3.9 1.1 TRUNCATED LOGNORMAL-N -6.21 1.1
.001
.999 TRUNCATED LOGNORMAL-N -6.21 1
.001
.999 TRUNCATED LOGNORMAL-N -9.72
.9
.001
.999 LOGNORMAL-N 3.2 1.1 fifftitftittt fftttttffit fittttffttttttftfttttttfttifitfff ttttttf 0151
.000016
.1365 IRESRAD1 Version 6.5 T-Limit = 30 days 11/27/2011 09:29 Page 20 Probabilistic results summary : He soil DCGL-EU-152 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\EU152 DCGL\\HB SOIL DCGLEU152.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1
0.000E+00 2.475E+00 1
BART LETT Page 74
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Eu-154 Results:
RESRAD, Version 6.5 T' Limit = 30 days 11/27/2011 09:50 Page I
Summary : HB soil DCGL._Eu-154 File
- C:\\RESRADFA.LY\\RESRAD\\6.5\\USERFILES\\EU154 DCGL\\HB SOIL DCGLEU154.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary...
2 Site-Specific Parameter Summary............................
3 Summary of Pathway Selections............................
7 Contaminated Zone and Total Dose Summary...................
8 Total Dose Components Time = O.OOOE+00..
9 Time = 1.000E+00.....................................
10 Time = 3.000E+00.....................................
11 Time = 1.000E+01.....................................
12 Time = 3.OOOE+01.....................................
13 Time = 1.OOOE+02..
14 Time = 3.OOOE+02..
15 Time = 1.000E+03..
16 Dose/Source Ratios Summed Over All Pathways 17 Single Radionuclide Soil Guidelines.......................
17 Dose Per Nuclide Summed Over All Pathways 18 Soil Concentration Per Nuclide...........................
18 IRESRAD, version 6.5 Ta' Limit = 30 days 11/27/2011 09:S0 Page 2
Summary : HB soil DCGLEu-154 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\EU154 DCGL\\HB SOIL DCGLEU154.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: HB DCGLs Plus FGR 12 & FGR 11 0
3 Current 3
Base Parameter Menu Pamer value#
Case*
I Nae*
A-1 DCF'S for external ground radiation, (mrem/yr)/(pCi/g)
A-1 Eu-154 (Source: FGR 12) a 7.678E+00 7.678E+00 DCF1(
1)
B-1
' Dose conversion factors for inhalation, mrem/pCi:
B-1 Eu-154 a 2.860E-04 2.860E-04 DCF2(
1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Eu-154 3 9.550E-06 9.550E-06 DCF3(
1)
D-34 Food transfer factors:
a D-34 Eu-154
, plant/soil concentration ratio, dimensionless 2.500E-03 2.500E-03 RTF(
1,1)
D-34 Eu-154 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 2.OOOE-03 2.OOOE-03 RTF(
1,2)
D-34 EU-154 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 5.OO0E-0S 5.OOOE-05 RTF(
1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 EU-154
, fish 5.000E+01 5.OOOE+01 BIOFAC(
1,i)
D-5 EU-154
,icrustacea and mollusks 1.OOOE+03 1.OOOE+03 BIOFAC(
1,2)
- For DCF1(xxx) only, factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Default.Lib w/o Associate Nuclide contributions.
IRESRAD, Version 6.5 Tn Limit = 30 days 11/27/2011 09:50 Page 3
Summary : HB soil DCGLEu-154 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\EU154 DCGL\\HB SOIL DCGLEU154.RAD 0Menu aParameter R011 Area of contaminated zone (m**2)
ROll Thickness of contaminated zone (m)
Roll Fraction of contamination that is submer Roll Length parallel to aquifer flow (m)
Roll Basic radiation dose limit (mrem/yr)
R011 Time since placement of material (yr)
R011 Times for calculations (yr)
R011 Times for calculations Cyr)
Roll Times for calculations (yr)
Roll Times for calculations Cyr)
Roll Times for calculations Cyr)
R011 Times for calculations (yr)
Roll Times for calculations Cyr)
Roll Times for calculations (yr)
R011 Times for calculations (yr)
R012 Initial principal radionuclide (pCi/g):
R012 Concentration in groundwater (pCi/L):
R013 Cover depth (m)
R013 Density of cover material (g/cm**3)
R013 Cover depth erosion rate (m/yr)
R013 a Density of contaminated zone (g/cm**3)
R013 Contaminated zone erosion rate (m/yr)
R013 Contaminated zone total porosity R013 Contaminated zone field capacity R013 contaminated zone hydraulic conductivity R013 Contaminated zone b parameter R013 3 Average annual wind speed (m/sec)
R013 Humidity in air (g/m**3)
R013 Evapotranspiration coefficient R013 a Precipitation (m/yr)
R013 Irrigation (m/yr)
R013 a Irrigation mode R013 Runoff coefficient R013 watershed area for nearby stream or pond R013 Accuracy for water/soil computations R014 a Density of saturated zone (g/cm**3)
R014 Saturated zone total porosity R014 Saturated zone effective porosity R014 Saturated zone field capacity R014 Saturated zone hydraulic conductivity (m site-Specific Parameter Summary a
User 3
Used by RESRAD Parameter
" Input a Default 3(If different from user input) a Name
- d. f 3.OOOE+04 1.000E+04 AREA 1.830E+00 2.OOOE+00 a THICKO ged O.00OE+-00 0.OO0E+OD SUBMFRACT 1.950E+02 1.O00E+02 LCZPAQ 2.500E+01 3.OOOE+01 BRDL 0.000E+00 a O.OOOE+00 a TI 1.000E+00 1.000E+OO T( 2) 3.OOOE+O0 3.OOOE+00 3 T( 3)
I.OOOE+O0 a l.OOOE+OI T( 4) 3.000E+O1 a 3.OOOE+O1 T( 5) a 1.000E+02 I 1.0OOE+02 T( 6) 3.OOOE+02 3.OOOE+02 T( 7) 1.000E+03 a 1.OOOE+03 3 a T( 8) not used 0.OOOE+OO T( 9) not used 0.OOOE+00 T(10)
Eu-154 a 1.000E+00 03OOOE+00 a SI(1)
Eu-154 a not used 0.OOOE+00 a Wl(i 1)
O.OOOE+0a 0.00OE+00 COVERO not used 1.50OE+O0 DENSCV not used 3 1.OOOE-03 VCV a 1.564E+00 a 1.500E+00 DENSCZ 2.200E-03 1.OOOE-03 VCZ a 4.100E-01 a 4.OOOE-01 a-a TPCZ 9.500E-02 2.OOOE-O1 FCCZ (m/yr) 3.900E+00 1.OOOE+01 a HCCZ S.600E+O0 5.300E+00 BCZ 3.040E+00 a 2.OOOE+00 WIND a not used a 8.000E+00 a HUMID a 6.250E-01 O5.O0E-O1 a-a EVAPTR a 9.100E-01 a 1.OOOE+00 PRECIP 5.600E-01 2.OOOE-01 a-a RI a overhead overhead alIDITCH 5.000E-01 a 2.OOOE-01 a-a RUNOFF (mW 2) 2.520E+07 a 1.OOOE+06 a-WAREA a 1.00OE-03 I 1.OOOE-03 EPS a 1.510E+00 ' 1.500E+00 a--
DENSAQ a 4.300E-01 I 4.OOOE-01 TPSZ 3.420E-01 a 2.OOOE-01 a--
EPSZ a 8.800E-02 a 2.OOOE-01 a FCSZ
/yr) 2.880E+01 a 1.OOOE+02 a-HCSZ 0
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R014 3 Saturated zone hydraulic gradient 2.OOOE-03 2.OOOE-02 R014 3 Saturated zone b parameter 7.100E+00 5.300E+00 R014 Water table drop rate (m/yr) 1.OOOE-03 I.OOOE-03 R014 Well pump intake depth (m below water table) 1.000E+0l l.000E+/-01 R014 Model: Nondispersion (ND) or Mass-Balance (MB)
ND ND R014 3 Well pumping rate (m**3/yr) 1.573E+03 2.500E+02 IRESRAD, version 6.5 Ta Limit = 30 days 11/27/2011 09:50 Page 4
summary : HB soil DCGLEu-154 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILEs\\EUI54 DCGL\\HB SOIL DCGL.EUlS4.RAD HGWT BSZ 3
VWT DWlBWT MODEL UW Site-Specif 0
3 Menu Parae
.ter R015 Number of unsaturated zone strata ROlS Unsat. zone 1, thickness (m)
R015 Unsat. zone 1, soil density (g/cm**3)
R015 Unsat. zone 1, total porosity RO15 Unsat, zone 1, effective porosity ROl5 Unsat. zone 1, field capacity R015 Unsat. zone 1, soil-specific b parameter R015 Unsat. zone 1, hydraulic conductivity (m/yr)
R016 Distribution coefficients for Eu-154 R016 Contaminated zone (cm-*3/g)
R016 Unsaturated zone 1 (cm**3/g)
R016 Saturated zone (cm**3/g)
R016 Leach rate (/yr)
R016 solubility constant R017 Inhalation rate (m-13/yr)
ROl7 Mass loading for inhalation (g/m**3)
R017 Exposure duration RO17 shielding factor, inhalation R017 shielding factor, external gamma ROl7 Fraction of time spent indoors ROl7 Fraction of time spent outdoors (on site)
R017 shape factor flag, external gamma R017 Radii of shaqe factor array (used if FS = -1):
R017 Outer annular radius (m),
ring 1
ROl7 Outer annular radius (m),
ring 2:
R017 Outer annular radius (m),
ring 3:
R017 Outer annular radius (m),
ring 4:
ROl7 Outer annular radius (m),
ring 5:
ROl7 Outer annular radius (m) ring 6:
ROll Outer annular radius (m): ring 7:
ROl7 Outer annular radius (m),
ring 8:
R017 Outer annular radius (m),
ring 9
R017 Outer annular radius (m),
ring 10:
R017 Outer annular radius (m),
ring 11:
RO17 Outer annular radius (m),
ring 12:
ic Parameter Summary (continued)
User U
Used by RESRAD 3
Parameter Input 3 Default 3 (If different from user input) 3 Name a
i l
kA A A A 5 A & S A S A A A A A A...............
4.040E+0O 4.OOOE+00 1.564E+00 1.500E+00 4.100E-01 4.OOOE-01
- 3.1SOE-Ol 2.OOOE-0l 9.500E-02 2.0OOE-01 5.600E+00 5.300E+00 3.900E+00 1.000E+01 8.250E+02 3-.,OOOE+00 1 8.25OE+02 3 -l.OOOE+00 8.250E+02 3 -1,OOOE+00 O.OOOE+00 O.OOOE+OO 3 0.OOOE+O0 O.OOOE+00.
3 8.400E+03 8.400E+03 1.OOOE-04 1.OOOE-04 3.OOOE+01 3.000E+01 5.50OE-01 4.OOOE-01 3.980E-01 7.00OE-01 6.571E-01 S.OOOE-01 1.181E-01 2.500E-01 1.0OOE+00 1.OOOE+00 not used S.00OE+O1 not used 7.071E+01 not used 0.OOOE+00 not used O.OOOE+00 not used O.O00E+O0 not used O.OOOE+00 not used
.O0OOE+0O not used O.OOOE+00 not used O.OOOE+00 not used O.OOOE+00 not used 0.O00E+00 not used 0.000E+0 1.612E-04 not used
>0 shows circular AREA.
NS H (1) 3 DENSUZ(1)
TPUZ(1)
EPUZ(1) 3 FCUZ(1) 3BUZ(1)
- HCUZ(1)
DCNUCC( 1)
DCNUCU( 1,1)
DCNUCS(
1)
ALEACH(
1)
SOLUBK(
1)
INHALR 3 MLINH ED SHF3 SHFl FIND FOTD FS RADSHAPE(
1)
RAD.SHAPE(
2)
RAD.SHAPE(
3)
RADSHAPE(
4)
RAD.SHAPE(
5)
PAD.SHAPE(
6)
P.ADSHAPE(
7)
RADSHAPE(
8)
PADSHAPE(
9)
RADSHAPE(10)
RADSHAPE(11) 3 RADSHAPE(12)
IRESRAD, Version 6.5 Ta Limit = 30 days 11/27/2011 09:50 Page 5
Summary : HB soil DCGLEU-154 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\EU154 DCGL\\HB SOIL DCGL.EU154.RAD Site-Specific 0
3 menuPaaer ROl7 Fractions of annular areas within AREA:
R017 Ring 1
ROll Ring 2
R017 Ring 3
R017 Ring 4
R017 Ring 5
ROl7 Ring 6
R017 Ring 7
ROl7 Ring 8
R017 Ring 9
RO17 Ring 10 R017 Ring 11 RO7I Ring 12 R018 Fruits, vegetables and grain consumption (kg/yr)
ROI8 Leafy vegetable consumption (kg/yr)
R018 Milk consumption (L/yr)
R018 Meat and poultry consumption Ckg/yr)
R018 Fish consumption Ckg/yr)
R018 Other seafood consumption (kg/yr)
R018 soil ingestion rate (g/yr)
R018 Drinking water intake (L/yr)
RO8 contamination fraction of drinking water R018 u contamination fraction of household water RO18 Contamination fraction of livestock water R018 contamination fraction of irrigation water R018 Contamination fraction of aquatic food RO18 contamination fraction of plant food R018 Contamination fraction of meat R018 Contamination fraction of milk R019 Livestock fodder intake for meat (kg/day)
R019 Livestock fodder intake for milk (kg/day)
R019 Livestock water intake for meat (L/day)
R019 Livestock water intake for milk (L/day)
R019 Livestock soil intake (kg/day)
RO09 Mass loading for foliar deposition (g/m**3)
R019 Depth of soil mixing layer (m)
RO09 Depth of roots (m)
R019 Drinking water fraction from ground water R019 Household water fraction from ground water RO9 Livestock water fraction from ground water R019 Irrigation fraction from groun water R19B Wet weight crop yield for Non-Leafy (kg/m**2)
R193 Wet weight crop yield for Leafy (kg/m.*2)
R19B Wet weight crop yield for Fodder (kg/m**2)
R19B Growing Season for Non-Leafy (years)
R19B Growing Season for Leafy (years)
R19B Growing Season for Fodder (years)
- B ARTLEfTT Parameter Summary (continued) 3 User 3 input Default
- (if
....~
f.....
not used 1.OOOE+00 not used 2.732E-01 not used O.OOOE+00 not used O.O00OE+OO not used O.OOOE+0O not used O.OOOE+O0 not used O.OOOE+00 not used O.OOOE+00 not used O.OOOE+O0 not used O.OOOE+00 not used 0.00OE+O0 not used O.OOOE+00 1.120E+02 1.600E+02 2.140E+01 1.400E+01 2.330E+02 9.200E+01 6.510E+01 6.300E+01 2.060E+O1 5.400E+00 9.000E-01 9.00OE-O1 1 1.826E+01 3.650E+01 4.785E+02 5.100E+02 I1.OOOE+00 1.OOOE+OO not used 1.OOOE+00 1.000E+00 3.OOOE+O0 I1.OO0E+0 1.00OE+O0 Il.OOOE+/-0O 3S.OOOE-Ol 1.000E+00 5.00-O
' 1.OOOE+00 3-1 3 1.000E+00 3-1
-1.O00E+00
- -1 2.710E+01 6.800E+01 6.320E+01 5.500E+01 5.060E+01 5.000E+O1 6.OOOE+01 1.600E+02 5.OOOE-01 5.00OE-01 4.OOOE-04 1.000E-04 2.300E-01 1.SOOE-01 2.150E+00 9.OOOE-01 1.OOOE+00 1.OOOE+/-OO not used 1.O00E+OO 1.OOOE+00 1.000E+O0 1.OOOE+00 1.000E+O0 1.750E+00 7.000E-01 2.889E+00 1.500E+00 1.887E+00 1.100E+00 2.460E-01 1.700E-01 1.230E-01 2.500E-01 8.200E-02 8.OOOE-02 used by RESRAD different from user
_~_AA A AA A Parameter
. p ).
.... Name akAaAW AAAAA4"AAA FPRACA( 1)
FPACAC 2)
PRACAC 3)
FRACA( 4)
PRACAC 5)
FRACA( 6) 3 FRACA( 7) 3 FRACAC 8) 3 FRACA( 9)
FRACA(1O) 3 FRACA(11) 3 FRACA(12)
DIET(1)
DIET(2)
DIET(3)
DIET(4)
DIET(S) 3 DIET(6)
SOIL DWI PDW FHHW FLW FIRW FR9 FPLANT FMEAT FMILK LFI5 LFI6 LWIS LWI6 LSI MLFD DM DROOT 3 FGWDW FGW1H FGWLW FGWIR Yv(2) wv(3)
TE(1)
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 IRESRAD, version 6.5 Tv Limit = 30 days 11/27/2011 09:50 Page 6
Summary HB soil DCGLEu-154 File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\EU154 DCGL\\HB SOIL DCGLEU154.RAD 0
Menu R19B R19B R19B R19B R19B R19B R19B R19B R19B R19B C14 C14 C14 C14 C14 C14 C14 C14 C14 STOR STOR STOR STOR STOR STOR STOR STOR STOR MTR RC21 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 3
Site-Specific 3
Parameter Translocation Factor for Nob-Leafy Translocation Factor for Leafy Translocation Factor for Fodder Dry Foliar Interception Fraction for Non-Leafy Dry Foliar Interception Fraction for Leafy Dry Foliar Interception Fraction for Fodder wet Foliar Interception Fraction for Non-Leafy wet Foliar Interception Fraction for Leafy wet Foliar Interception Fraction for Fodder weathering Removal Constant for vegetation C-12 concentration in water (g/cm**3)
C-12 concentration in contaminated soil (g/g)
Fraction of vegetation carbon from soil Fraction of vegetation carbon from air C-14 evasion layer thickness in soil (m)
C-14 evasion flux rate from soil (1/sec)
C-12 evasion flux rate from soil (1/sec)
Fraction of grain in beef cattle feed Fraction of grain in milk cow feed Storage times of contaminated foodstuffs (days):
Fruits, non-leafy vegetables, and grain Leafy vegetablds Milk Meat and poultry Fish Crustacea and mollusks well water Surface water Livestock fodder Thickness of building foundation (m)
Bulk density of building foundation (g/cm**3)
Total porosity of the cover material Total porosity of the building foundation volumetric water content of the cover material volumetric water content of the foundation Diffusion coefficient for radon gas (m/sec):
in cover material in foundation material in contaminated zone soil Radon vertical dimension of mixing (m)
Average building air exchange rate (1/hr)
Height of the building (room)
(m)
Building interior area factor Building depth below ground surface (m)
Emanating power of Rn-222 gas Emanating power of Rn-220 gas Parameter Summary (contin a
i User 3
3 Input 3
Default a 1.000E-01 ' 1.000E-01 1.000E +00 31.000E+00 1
1.000E+O0 1.OOOE+00 S3.500E-01 2.500E-010 3 3.500E-01 2.500E-01 3.500E-01 2.500E-01 3.500E-01 2.500E-01 5.800E-01 2.500E-01 3.500E-01 2.500E-01 3.300E+01 2.0OOE+01 not used 2.OOOE-05 not used 3.0OOE-02 not used 2.0OOE-02 not used 9.800E-01 not used 3.OOOE-01 not used 7.000E-07 not used 1.000E-10 not used 38.00E-01 not used 2.000E-01 1.400E+01 1.400E+01 1.000E+00 1.000E+O0 1.000E+00 1.0OOE+O0 2.OOOE+01 2.000E+01 7.000E+O0 7.000E+00 7.00OE+00 7.O00E+00
'.1.000E+00 1.000E+00 1.000E+00 1.000E+00 4.500E+01 4.500E+01 not used 1.500E-01 not used 2.400E+00 not used 4.000E-01 not used 1.000E-01 not used S.000E-02 not used 3.OOOE-02 not used 2.000E-06 not used 3.000E-07 not used 2.000E-06 not used 2.000E+O0 not used 5.000E-01 not used 2.500E+00 not used 0.OOOE+00 not used
-I.000sE+00 not used 3 2.500E-01 not used 3 1.500E-01 used by RESRAD Parameter (if different from user input)
Name TIV (1)
TIv(2)
TIV(3)
RDRY(I)
RDRY(2)
- RDRY(3) 3RWET1)
RWET(2)
' RWET(3) 3WLAM C12WTR C12CZ CSOIL CAIR DMC EVSN REVSN AVFG4 AVFG5 STOR-T(1) 3 STOR.T(2)
' STOR.T(3) 3 STORT(4)
STOR.T(5)
STOR.T(6)
STORJT(7) 3STOR-T(8) 3STORT(9)
FLOORI DENSFL TPCV TPFL 3 PH2OCV PH2OFL DIFCV DIFFL DIFCZ HMIX REXG HRM FAI DMFL EMANA(1)
EMANA(2)
NPTS TITL Number of graphical time points 32 IRESRAD, Version 6.5 Tm Limit = 30 days 11/27/2011 09:50 Page 7
Summary : HB soil DCGLEu-154 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\EU154 DCGL\\HB SOIL DCGLEU154.RAD Site-Specific Parameter Summary (continued) 0 1
3 user ffused by RESRAD 3
Parameter menu 3Parameter 3
input
'Default (If different from user input) '
Name A...
eA
.AdA..
.AiA
.N e....
TITL Maximum number of integration points for dose 17 LYMAX TITL Maximum number of integration points for risk 1
KY3AX Summary of Pathway Selections
.!*!i~pyUser Selection 1-- external gamma active 2
inhalation (w/o radon)3 active 3-- plant ingestion active 4
meat ingestion active 5
milk ingestion active 6
aquatic foods active 7
drinking water active 8
soil ingestion active 9 --
radon suppressed Find peak pathway doses I
active IRESRAD, version 6.5 Tm Limit = 30 days 11/27/2011 09:50 Page 8
Summary : HB soil DCGLEU-154 File
- C:\\RESRADoFAMILY\\RESRAD\\6.5\\USERFILES\\Eul54 DCGL\\HB SOIL DCGLEU154.RAD Contaminated Zone Dimensions Initial Soil Concentrations..../g KKKA lXSKXXXXKAAAAAAAAAAAAAAA AAAAA Area:
30000.00 square meters EU-154 1.OOOE+00 Thickness:
1.83 meters Cover Depth:
0.00 meters IRESRAD, version 6.5 T" Limit = 30 days 11/27/2011 09:50 Page 1
Probabilistic results summary : HB soil DCGLEu-154 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\EU154 DCGL\\HB SOIL DCGLEU154.RAD Table of Contents Part VI: Uncertainty Analysis ORESRAD uncertainty Analysis Results Probabilistic Input..
2 Total Dose...........
3 Total Risk..........................................
4 t
BARTLETT Page 77
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Dose vs Pathway:
Ground External...................
5 Dose vs Pathway:
Inhalation (W/o Radon)..............
6 Dose vs Pathway:
Radon (Water Ind.)..................
7 Dose vs Pathway:
Plant (water Ind.).................
8 Dose vs Pathway:
Meat (water Ind.).................
9 Dose vs Pathway:
Milk (water Ind.).................
10 Dose vs Pathway:
Soil Ingestion....................
11 Dose vs Pathway:
Water Ingestion...................
12 Dose vs Pathway:
Fish Ingestion....................
13 Dose vs Pathway:
Radon (Water Dep.)
14 Dose vs Pathway:
Plant (Water Dep.)................
15 Dose VS Pathway:
Meat (water Dep.)
16 Dose VS Pathway:
Milk (water Dep.)
17 Cumulative Probability Summary.......................
18 Summary of dose at graphical times, reptition 1.....
19 Peak of the mean dose at graphical times.............
20 Correlation and Regression coefficients (if any).....
21 IRESRAD, version 6.5 T-Limit = 30 days 11/27/2011 09:50 Page 2
Probabilistic results summ ary : HB soil DCGL-Eu-1S4 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\EUIS4 DCGL\\HB SOIL DCGLEU154.RAD probabilistic Input ONumber of Sample Runs: 2000 Number Name Distribution AAAAAA WAA AAAMA xXAxxxxAxAxxAA uxuxxAx 1
THICKO UNIFORM 2
DENSCZ BOUNDED NORMAL 3
TPCZ BOUNDED NORMAL 4
HCCZ BOUNDED LOGNORMAL-N 5
BCZ BOUNDED LOGNORMAL-N 6
EVAPTR UNIFORM 7
RI UNIFORM 8
DENSAQ BOUNDED NORMAL 9
TPSZ BOUNDED NORMAL 10 EPSZ BOUNDED NORMAL 11 HCSZ BOUNDED LOGNORMAL-N 12 BSZ BOUNDED LOGNORMAL-N 13 DWIBWT TRIANGULAR 14 UW UNIFORM 15 H(1)
UNIFORM 16 DENSUZ(1)
BOUNDED NORMAL 17 TPUZ(1)
BOUNDED NORMAL 18 EPUZ(1)
BOUNDED NORMAL 19 HCUZ(1)
BOUNDED LOGNORMAL-N 20 BUZ(1)
BOUNDED LOGNORMAL-N 21 MLINH CONTINUOUS LINEAR
.00003
.8119
.00004
.9495
.00006
.9937 22 SHF3 UNIFORM 23 DM TRIANGULAR 24 DROOT UNIFORM 25 Wv(1)
TRUNCATED LOGNORMAL-N 26 WLAM TRIANGULAR 27 RWET(2)
TRIANGULAR 28 DCACTC(1)
TRUNCATED LOGNORMAL-N 29 DCACTU1(1)
TRUNCATED LOGNORMAL-N 30 DCACTS(1)
TRUNCATED LOGNORMAL-N 31 BRTF(63,1)
TRUNCATED LOGNORMAL-N 32 BRTF(63,2)
TRUNCATED LOGNORMAL-N 33 BRTF(63,3)
TRUNCATED LOGNORMAL-N 34 BBIO(63,1)
LOGNORMAL-N
+/-1+/-313 3ti+/-ti+/-tttttt tt1t+/-t3I+/-
31+/-+/-3t3311ttt+/-3333+/-
3i3 Parameters
.15 3.51 1.5635
.2385
.827 2.3
.41
.09
.1319
.6881 1.36 2.17
.00478 3190 1.73
.323 2.08 15.3
.5
.7S
.36
.76 1.5105
.1855
.937 2.084
.43
.0699
.214
.646
.342
.0705
.124
.56
.362 1.59
.0106 195 1.96
.265 3.02 15.5 6
10 30 1173 1973 0
8.08 1.5635
.2385
.827 2.3
.41
.09
.1319
.6881
.315
.0905
.0349
.594 1.36 2.17
.00478 3190 1.73
.323 2.08 15.3 8
0 0
.000008
.0151
.000016
.1365
.000076
.9983
.0001 1
.15
.95 0
.15
.6
.3 4
.56
.48
.001
.999 5.1 18 84
.06
.67
.95 6.72 3.22
.001
.999 6.72 3.22
.001
.999 6.72 3.22
.001
.999
-6.21 1.1
.001
.999
-6.21 1
.001
.999
-9.72
.9
.001
.999 3.9 1.1 It+/-1tttttt3tI+/-3ttII+/-333+/-tfti+/-ti+/-+/-t+/-+/-tttt t+/-3+/-t1i+/-
t1t3t+/-1t 13+/-11tlIt ttMtMttIl M33+/-1333 MUM ttt3t MUM 3it t
it+/-1tt11
- 1RESRAD, Version 6.5 T-Limit = 30 days 11/27/2011 09:50 Page 20 Probabilistic results summary : HB soil DCGL--EU-154 File : C:\\RESRAD.FAMILY\\RESRAD\\6.5\\USERFILES\\EU1S4 DCGL\\HB SOIL DCGL-EU154.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1
0.OOOE+00 2.660E+00
(
BARTLETT Page 78
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 H-3 Results:
1RESRAD, Version 6.5 T< Limit = 30 days 11/27/2011 10:07 Page I
Summary : HB soil DCGL-H-3 File C:\\RESRADSFAMILY\\RESRAD\\6.5\\USERFILES\\H3 DCGL\\HB SOIL DCGLH3.RAD Table of Contents Part I: Mixture Sums and Sinqle Radionuclide Guidelines liffilittlitffliff I, f f tl t*t~ttttiffiffiftttlifif1t Dose Conversion Factor (and Related) Parameter Summary...
2 site-Specific Parameter Summary............................
3 Summary of Pathway Selections..............................
7 Contaminated Zone and Total Dose Summary.................
8 Total Dose components Time = 0.O00E+00....................................
. 9 Time = 1.000E+00....................................
10 Time = 3.000E+00.....................................
11 Time = 1.000E+01.....................................
12 Time = 3.000E+01.....................................
13 Time = 1.000E+02....................................
14 Time = 3.000E+02.....................................
15 Time = 1.000E+03....................................
16 Dose/source Ratios Summed Over All Pathways..............
17 Single Radionuclide Soil Guidelines......................
17 Dose Per Nuclide Summed Over All Pathways................
18 Soil Concentration Per Nuclide...........................
18 IRESRAD, Version 6.5 To Limit = 30 days 11/27/2011 10:07 Page 2
Summary : HB soil DCGLH-3 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\H3 DCGL\\HB SOIL DCGL_H3.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: HB DCGLs Plus FGR 12 & FGR 11 0
Current 3
Base 3
Parameter Menu 3 Parameter I
Value#
3 Case*
3 Name A-i DCF's for external ground radiation, (mrem/yr)/(pCi/g)
A-i H-3 (Source:
FGR 12) 0.00E+0O0 O.000E+0 DCF1(
1)
B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 H-3 6.400E-08 6.400E-08 DCF2(
1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 H-3 6.400E-08 6.400E-08 DCF3(
1)
D-34 Food transfer factors:
D-34 H-3
, plant/soil concentration ratio, dimensionless 4.800E+00 3 4.800E+00 RTF(
1,1)
D-34 H-3 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.200E-02 1.200E-02 RTF(
1,2)
D-34 H-3 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.000E-02 1.OOOE-02 RTF(
1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 H-3
, fish 1.000E+00 1.000E+00 BIOFAC(
1,1)
D-5 H-3 crustacea and mollusks 1.000E+00 1.000E+00 BIOFACf 1,2)
- For DCFI(xxx) only, factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Default.Lib w/o Associate Nuclide contributions.
IRESRAD, Version 6.5 To Limit = 30 days 11/27/2011 10:07 Page 3
Summary : HB soil DCGLH-3 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\H3 DCGL\\HB SOIL DCGL_H3.RAD 0
Menu.;
Site-Specific Parameter Summary User t used by RESRAD Parameter
.p u
r..
p.....
.N a m e Parameter kAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAWAAA R011 Area of contaminated zone (m 3 *2)
R011 Thickness of contaminated zone (m)
Roll Fraction of contamination that is submerged R011 Length parallel to aquifer flow (m)
Roll Basic radiation dose limit (mrem/yr)
R011 Time since placement of material (yr)
R011 Times for calculations (yr)
Roll Times for calculations (yr)
Roll Times for calculations (yr)
Roll 3 Times for calculations (yr)
Roll 3 Times for calculations (yr)
Roll Times for calculations (yr)
Roll Times for calculations (yr)
Roll Times for calculations (yr)
Roll Times for calculations (yr)
R012 Initial principal radionuclide (pCi/g):
H-3 R012 Concentration in groundwater (pCi/L):
H-3 R013 Cover depth (m)
R013 Density of cover material (g/cm**3)
R013 Cover depth erosion rate (m/yr)
R013 Density of contaminated zone (g/cm-*3)
R013 Contaminated zone erosion rate (m/yr)
R013 Contaminated zone total porosity R013 Contaminated zone field capacity R013 Contaminated zone hydraulic conductivity (m/yr)
R013 Contaminated zone b parameter R013 Average annual wind speed (m/sec)
R013 Humidity in air (g/m*3)
R013 Evapotranspiration coefficient R013 Precipitation (m/yr)
R013 Irrigation (m/yr)
R013 Irrigation mode R013 Runoff coefficient R013 watershed area for nearby stream or pond (m**2)
R013 Accuracy for water/soil computations R014 Density of saturated zone (g/cm**3)
R014 Saturated zone total porosity R014 saturated zone effective porosity R014 Saturated zone field capacity 3.0008+04 3 1.000E+04 2.670E+00 2.0OOE+00 O.000E+00 O.000E+00 1.950E+02 3.1.000E+02 2.500E+01 3.000E+01 O.000E+00 O.O000E+0 1.O008E+0 1.000E+00 3.000E+00 3.000E+00 1.000E+01 1.000E+O0 3.0008E+O 3.000E+OI 1.000E+02 1.000F+02 3.000E+02 3.000E+02 1.000E+03
.O000E+03 not used 0.O00E+00 not used O.O00E+00 1.000E+00 O.O00E+O0 not used 0.008E+00 O.000E+00 O.008E+00 not used 3 1.500E+00 not used 1.O00E-03 1.564E+00 1.500E+00 2.200E-03 1.O00E-03 4.100E-01 4.000E-01 9.500E-02 2.000E-01 3.900E+00 1.000E+01 5.600E+00 5.300E+00 3.040E+00 2.000E+00 8.200E+00 8.0008E+0 6.250E-01 5.000E-01 9.100E-01 1.O00E+O0 5.600E-01 2.000E-O0 overhead overhead 5.000E-O1 2.000E-01 2.520E+07 1.000E+06 1.O00E-03 1.O00E-03 1.510E+00 1.500E+00 4.300E-01 4.OOOE-01 3.420E-01 2.000E-01 8.800E-02 3 2.000E-01 AREA THICKO SUBMFRACT LCZPAQ BRDL TI T(
2)
T( 3)
T( 4)
T( 5)
T( 6)
T( 7)
T(
8)
T( 9)
T(10)
S1(1) wl( 1)
COVERO DENSCV VCV DENSCZ VCZ TPCZ FCCZ HCCZ BCZ WIND HUMID EVAPTR PRECIP RI IDITCH RUNOFF WAREA EPS DENSAQ TPSZ EPSZ 3 FCSZ t
BARTLETT Page 79
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R014 3 Saturated zone hydraulic conductivity (m/yr) 2.880E+01 3 1.O00E+02 R014 s
saturated zone hydraulic gradient 2.000E-03 I 2.000E-02 R014 3 Saturated zone b parameter 7.100E+00 I 5.300E+00 RO14 w
water table drop rate (m/yr) 1.000E-03 ' 1.O00E-03 R014 3 well pump intake depth (m below water table) 1.OOOE+01 ' 1.OOOE+01 R014 Model: Nondispersion (ND) or Mass-Balance (MB)
ND
' NO R014 well pumping rate (m**3/yr) 1.573E+03 3 2.500E+O2 1RESRAD, Version 6.5 Tc' Limit = 30 days 11/27/2011 10:07 Page 4
Summary HB soil DCGLH-3 File
- C:\\RESRAD-FAMILY\\RESRAD\\6.5\\USERFILES\\H3 DCGL\\HB SOIL DCGLH3.RAD Site-Specific Parameter Summary (continued) 0 33 User Menu 3 Parameter put 3Default (if ROlS Number of unsaturated zone strata 1
. 1 R015 Unsat. zone 1, thickness (i) 4.040E+00 4.O00E+O0 RO15 Unsat. zone 1, soil density (g/cm**3) 3 1.564E+00 1.SOOE+00 ROlS Unsat. zone 1, total porosity 4.100E-01 I 4.OOOE-0l R015 Unsat. zone 1, effective porosity 3 3.1SOE-01 2.000E-O1 RO15 Unsat. zone 1, field capacity 9.500E-02 2.000E-01 R015 Unsat. zone 1, soil-specific b parameter 5.600E+00 5.300E+00 R015 Unsat. zone 1, hydraulic conductivity (m/yr) 3.900E+00 1.OOOE+0l R016 Distribution coefficients for H-3 R016 Contaminated zone (cm**3/g) 4.300E-02 O.OOOE+00 R016 unsaturated zone 1 (cm**3/g) 6.000E-02 O.OOOE+O0 R016 Saturated zone (cm**3/g) 6.OOOE-02 O.O00E+O0 R016 Leach rate (/yr)
O.OOOE+00 O.O00E+00 R016 solubility constant 3.OOOE+00 O.OOOE+00 R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 RO17 Mass loading for inhalation (g/m**3) 1.OOOE-04 1.000E-04 ROl7 Exposure duration 3.000E+01 3.OOOE+01 RO17 Shielding factor, inhalation 5.500E-01 4.OOOE-01 R017 I Shielding factor, external gamma 2.725E-01 7.0OOE-01I RO17 3 Fraction of time spent indoors 6.571E-01 5.OOOE-0l ROl7 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 RO17 Shape factor flag, external gamma 1.OOOE+00 l.OOOE+00 RO17 Radii of shape factor array (used if F5 = -1):
RO17 outer annular radius (m),
ring 1:
not used 5.OOOE+0l RO17 Outer annular radius (m),
ring 2:
not used 7.071E+01 R017 outer annular radius (m),
ring 3:
not used O.OOOE+00 ROl7 Outer annular radius (m),
ring 4:
not used O.OOOE+00 R017 Outer annular radius (m),
ring 5
not used O.OOOE+00 R017 Outer annular radius (m),
ring 6:
not used O.OOOE+O0 RO17 Outer annular radius (m),
ring 7:
not used OOOOE+O0 RO17 Outer annular radius (m),
ring 8
not used 0.OOOE+0O RO17 Outer annular radius (m),
ring 9:
not used 0.OOOE+00 R017 Outer annular radius (i),
ring 10:
not used 0.0OOE+0O RO17 Outer annular radius (m): ring 11:
not used OOOE+00I ROl7 Outer annular radius (m),
ring 12:
not used I.OOOOE00 1RESRAD, version 6.5 To Limit = 30 days 11/27/2011 10:07 Page Summary : HB soil DCGLH-3 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\H3 DCGL\\HB SOIL DCGL.H3.RAD Site-Specific Parameter Summary (continued) 0 User 3
3 menu Parameter 3
Inp.ut 3Default ' (if R017 Fractions of annular areas within AREA:
R017 Ring 1
3 not used 3 1.OOOE+00 ROlI Ring 2
not used 3 2.732E-01 R017 Ring 3
not used O.OOOE+00 RO17 Ring 4
3 not used O.OOOE+00 ROl7 Ring 5
not used 3 O.0OOE+0O R017 Ring 6
not used O.OOOE+00 R017 Ring 7
3 not used O.O0OE+0O R017 Ring 8
not used O.OOOE+00 RO7I Ring 9
not used O.O00E+00 RolI Ring 10 not used O.OOOE+00 RO17 Ring 11 not used O.oOOE+0O Roll I Ring 12 not used O.008E+00 R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 RO18 Milk consumption (L/yr) 2.330E+02 9.200E+01 RO8 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 R018 other seafood consumption (kg/yr) 9.OOOE-01 9.OOOE-0l RO18 soil ingestion rate (g/yr) 1.826E+01 3.650E+01 RO18 Drinking water intake (L/yr) 4.785E+02 5.100E+02 R018 Contamination fraction of drinking water 1.0OOE+00 I1.OOOE+O0 RO18 Contamination fraction of household water not used I.OOOE+0O R018 Contamination fraction of livestock water I 1.OOOE+00 1.O00E+00 R018 Contamination fraction of irrigation water 1.OOOE+0O l.OOOE+O0 RO18 Contamination fraction of aquatic food
.O0OOE+0O 5.O00E-01 RO18 Contamination fraction of plant food 1.OOOE+00 '-1 RO18 3 Contamination fraction of meat l.OOOE+00 '-1 R018 Contamination fraction of milk 1.00OE+00 '-1 8019 ' Livestock fodder intake for meat (kg/day) 2.710E+01 6.8008+0 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 6.500E+01 R019 Livestock water intake for meat (L/day) 5.060E+01 5.O000E+O R019 Livestock water intake for milk (L/day) 6.OOOE+0l 1.600E+02 R019 Livestock soil intake (kg/day) 5.OOOE0-O 5.OOOE-01 R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.0OOE-04 R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-0l R019 Depth of roots Wm)
I1220E+00 9.OOOE-0l R019 Drinking water fraction from ground water 31.000E+0O 1.OOOE+00 R019 Household water fraction from ground water not used 3 1.OOOE+OO R019 3 Livestock water fraction from ground water 1,000E+00 3 1.00OE+00 R019 Irrigation fraction from ground water 1.000E+00 1.OOOE+00 R19B wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000-E01 R19B wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 R19B wet weight crop yield for Fodder (kg/m 5 2) 1.887E+00 1.100E+00 R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 R
3 9
Grnwinn Seasnn fnr Iafv (vears)
L 23OF-n1 1 2_AOF-01 I 3 HCSZ 3 HGWT 13SZ
-- DWIBwT MODEL Used by RESRAD Parameter different from user input)
Name NS SH(1)
DENSUZ(1)
' TPUZ(1)
-- EPUZ(1)
FCUZ(1) 3 BUZ(1)
-- HCuZ(l)
DCNUCC( 1)
DCNUCU( 1,1) 3 DCNUCS( 1) 3.433E-01 ALEACH( 1) not used SOLUBK(
1)
INHALR MLINH ED SHF3 3 SHF1 FIND 3 FOTD 0 shows circular AREA.
FS 3 RADSHAPE(
1) 3 RADSHAPE(
2) 3 RAD.SHAPE(
3)
RAD.SHAPE(
4) 3 RADSHAPE(
5)
RA.ADSHAPE( 6) 3 RAD.SHAPE(
7)
R RAD.SHAPE(
8)
R AAD_SHAPE( 9) 3 R--ADSHAPE(10) 3 RAD-SHAPE(11) 3 RAD.SHAPE(12) used by RESRAD different from user input)
X
__XXXX~
aAAaA~
Parameter Name FRACA(
1)
FRACA(
2)
FRACA(
3)
FRACAC 4)
FRACA(
5)
FRACA( 6)
FRACA(
7)
FRACA( 8)
FRACA( 9)
FRACA(IO)
FRACA(11) 3 FRACA(12)
DIET(1) 3 DIET(2)
DIET(3)
DIET(4)
DIET(5)
DIET(6)
SOIL DWI FDW FHHW FLW FIRW FR9 FPLANT FMEAT FMILK LFIS LFI6 3 LWI5 LWI6 LSI MLFD 3DM 3 DROOT 3 FGWow
' FGWHH 3 FGWLW FGWIR YVMi YV(2)
Yv(3)
TE(1)
TF(2I 197BART LETT Page 80
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R198 e
Growing Season for Fodder (years)
I 8.200E-02 I 8.000E-02 IRESRAD, version 6.5 Ta Limit = 30 days 11/27/2011 10:07 Page 6
Summary : HB soil DCGLH-3 File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\H3 DCGL\\HB SOIL DCGL_H3.RAD TE(3) 0 menu Site-specific Parameter Summary (continued)
U User 3
ffUsed by RESRAD 3 Parameter
.fr t
..r m inp ut).....
Parameter AAAA
ýAA R19B Translocation Factor for Non-Leafy 1.OOOE-01 1.000E R19B Translocation Factor for Leafy 1.OOOE+00 1.OOE R19B Translocation Factor for Fodder 1.000E+00 1.OOOE R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E R19B Dry Foliar Interception Fraction for Leafy 3.S00E-01 2.500E R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E R19B wet Foliar Interception Fraction for Non-Leafy 3 3.500E-01 2.500E R19B wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E R19B wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E R19B weathering Removal Constant for Vegetation 3.300E+01 2.OOOE C14 C-12 concentration in water (g/cm**3) not used 2.OOOE C14 C-12 concentration in contaminated soil (g/g) not used 3.OOOE C14 Fraction of vegetation carbon from soil not used 2.OOOE C14 Fraction of vegetation carbon from air not used 9.800E C14 C-14 evasion layer thickness in soil (m) not used 3.OOOE C14 C-14 evasion flux rate from soil (1/sec) not used 7.OOOE C14 C-12 evasion flux rate from soil (1/sec) not used 1.OO0E C14 Fraction of grain in beef cattle feed not used 8.OOOE C14 Fraction of grain in milk cow feed not used 2.OOOE STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain a 1.400E+01 1.400E STOR Leafy vegetables 1.000E+00 1.000E STOR Milk 1.OO0E+00 1.000E STOR Meat and poultry 2.000E+01 2.OOOE STOR Fish 7.00OE+00 7.OOOE STOR Crustacea and mollusks 7.OOOE+00 7.OOOE STOR Well water 1.000E+00 1.000E STOR Surface water 1.OOOE+00 1.OOOE STOR Livestock fodder 4.SOOE+01 4.500E R021 Thickness of building foundation (m).
not used 1.500E R021 Bulk density of building foundation (g/cm**3) not used 2.400E R0213 Total porosity of the cover material not used 4.OOOE R021 3 Total porosity of the building foundation not used 1.OOOE R021 Volumetric water content of the cover material not used 5.OOOE R021 volumetric water content of the foundation a not used 3.OOOE R021 Diffusion coefficient for radon gas (m/sec):
a R021 in cover material not used 2.OOOE R021 in foundation material not used 3.OOOE R021 in contaminated zone soil not used 2.OOOE R021 Radon vertical dimension of mixing (m) not used 2.OOOE R021 Average building air exchange rate (1/hr) not used S.000E R021 Height of the building (room)
(m) not used 2.500E R021 Building interior area factor not used 0.000E R021 Building depth below ground surface (m) not used 3-1.000E R021 Emanating power of Rn-222 gas not used 3 2.SOOE R021 Emanating power of Rn-220 gas not used 3 1.500E TITL Number of graphical time points 32 1RESRAD, version 6.5 17< Limit = 30 days 11/27/2011 10:07 Page Summary : HB soil DCGL.H-3 File
- C:\\RESRADFAMILY\\RESBAD\\6.S\\USERFILES\\H3 DCGL\\HB SOIL DCGL_H3.RAD
-01
+00
+00
-01
-01
-01
-01
-01
-01
+01
-05
-02
-02
-01
-01
-07
-10
-01
-01
+01
+00
+00
+01
+00
+00
+00
+00
+01
-01
+00
-01
-01
-02
-02
-06
-07
-06
+00
-01
+00
+00
+00
-01
-01 7
TIV(1) 3 TIV(2) 3 TIV(3)
RDRY(1)
RDRY(2)
RDRY(3)
RWET(1)
RWET(2)
RWET(3)
WLAM C12WTR C12CZ CSOIL CAIR DMC EVSN REVSN AVFG4 AVFG5 STOR-T(1)
STOR-T(2)
STORST(3)
STOR&T(4)
STORST(S) 3 STORBT(6) 3 STORT(7)
STORT(8)
STORZT(9) 3 FLOORi DENSFL TPCV TPFL PH2OCV PH2OFL DIFCV DIFFL DIFCZ HMIX REXG HRM FAI DMFL EMANA(1)
EMANA(2)
NPTS Site-Specific Parameter Summary (continued) 0 User used by RESRAD Parameter Menu Paret ut De.faul.t....
(If different... rom.use*r..input) 3 Name TITL 3 Maximum number of integration points for dose 3
17 3 LYMAX TITL 3 Maximum number of integration points for risk 3
1 3
' KYMAX Summary of Pathway Selections
.athway 3
User Selection 1-- external gamma 3
active 2
inhalation (w/o radon) 3 active 3-- plant ingestion active 4
meat ingestion active 5
milk ingestion active 6
aquatic foods active 7
drinking water active 8
soil ingestion active 9
radon 3
suppressed Find peak pathway doses 3
active tfifit tiffttlfttfltttftttttttttttIttiflftfftfiftt 1RESRAD, Version 6.5 T' Limit = 30 days 11/27/2011 10:07 Page 8
Summary : HB soil DCGLJH-3 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\N3 DCGL\\HB SOIL DCGL_H3.RAD Contaminated zone Dimensions Area:
30000.00 square meters Thickness:
2.67 meters Cover Depth:
0.00 meters Initial Soil Concentrations pCi/g H-3 1.000E+00 IRESRAD, Version 6.5 Tc' Limit = 30 days 11/27/2011 10:07 Page Probabilistic results summary : HB soil DCGL--H-3 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\H3 DCGL\\HB SOIL DCGL_H3.RAD Table of Contents Part VI: Uncertainty Analysis ffttfttttttitttiitttfjttttfttt ORESRAD Uncertainty Analysis Results Probabilistic Input.................................
2 t
BARTLETT Page 81
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Total Dose...
3 Total Risk..........................................
4 Dose vs Pathway:
Ground External...................
5 Dose vs Pathway:
Inhalation (w/o Radon) 6 Dose vs Pathway:
Radon (Water Ind.)................
7 Dose vs Pathway:
Plant (Water Ind.)................
8 Dose vs Pathway:
Meat (Water Ind.)................
9 Dose vs Pathway:
Milk (Water Ind.)................
10 Dose vs Pathway:
Soil Ingestion...................
11 Dose vs Pathway:
Water Ingestion...................
12 Dose vs Pathway:
Fish Ingestion...................
13 Dose vs Pathway:
Radon (Water Dep.)................
14 Dose vs Pathway:
Plant (Water Dep.)
15 Dose vs Pathway:
Meat (Water Dep.)
16 Dose vs Pathway:
Milk (Water Dep.)
17 cumulative Probability Summary.......................
18 Summary of dose at graphical times, reptition 1...
19 Peak of the mean dose at graphical times.............
20 correlation and Regression coefficients (if any).....
21 1RESRAD, Version 6.5 T'c Limit = 30 days 11/27/2011 10:07 Page 2
Probabilistic results summary : HB soil DCGL-H-3 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\H3 DCGL\\HB SOIL DCGLH3.RAD Probabilistic Input ONumber of Sample Runs: 2000 Number 1
2 3
45 6
7 8
9 10 11 12 13 14 15 16 17 18 19 20
.00003 21 22 23 24 25 26 27 28 29 30 31 32 fffi11 Name DENSCZ TPCZ HCCZ BCZ EVAPTR RI DENSAQ TPSZ EPSZ HCSZ BSZ DWIBWT UW H(1)
DENSUZ(1)
TPUZ(1)
EPUZ(1)
HCUZ(1)
BUZ(1)
MLINH
.8119 SHF3 SHF1 DM YV(1)
WLAM RWET(2)
DCACTUI(1)
DCACTS(1)
BRTF(1,1)
BRTF(1,2)
BRTF(1, 3)
BBIO(1 1) f ttitftfft Distribution Parameters BOUNDED NORMAL 1.5635
.2385
.827 2.3 BOUNDED NORMAL
.41
.09
.1319
.6881 BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 UNIFORM
.5
.75 UNIFORM
.36
.76 BOUNDED NORMAL 1.5105
.1855
.937 2.084 BOUNDED NORMAL
.43
.0699
.214
.646 BOUNDED NORMAL
.342
.0705
.124
.56 BOUNDED LOGNORMAL-N.362 1.59
.0106 195 BOUNDED LOGNORMAL-N 1.96
.265 3.02 15.5 TRIANGULAR 6
10 30 UNIFORM 1173 1973 UNIFORM 0
8.08 BOUNDED NORMAL 1.5635
.2385
.827 2.3 BOUNDED NORMAL
.41
.09
.1319
.6881 BOUNDED NORMAL
.315
.0905
.0349
.594 BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 CONTINUOUS LINEAR 8
0 0
.000008
.00004
.9495
.00006
.9937
.000076
.9983
.0001 1
UNIFORM
.15
.95 BOUNDED LOGNORMAL-N -1.3
.59
.044 1
TRIANGULAR 0
.15
.6 TRUNCATED LOGNORMAL-N.56
.48
.001
.999 TRIANGULAR 5.1 18 84 TRIANGULAR
.06
.67
.95 TRUNCATED LOGNORMAL-N
-2.81
.5
.001
.999 TRUNCATED LOGNORMAL-N -2.81
.5
.001
.999 TRUNCATED LOGNORMAL-N 1.57 1.5
.001
.999 TRUNCATED LOGNORMAL-N -4.42 1
.001
.999 TRUNCATED LOGNORMAL-N -4.6
.9
.001
.999 LOGNOCGMAL-N 0
.1 tIttttftit ttffi fffiLOGNORMAtL-Nt0tt 1fttit*
0151
.000016
.1365 IRESRAD, Version 6.5 T" Limit = 30 days 11/27/2011 10:07 Page 20 Probabilistic results summary : HB soil DCGL-H-3 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\H3 DCGL\\HB SOIL DCGLH3.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1
0.00E+00 3.646E-02 B ART LETT Page 82
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 1-129 Results:
IRESRAD, Version 6.5 T-Limit = 30 days 11/27/2011 10:26 Page 1
Summary HB soil DCGL_Il29 File
- C:\\RESRAD-FAMILY\\RESRAD\\6.S\\USERFILES\\I29 DCGL\\HB SOIL DCGL_I129.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines fifili1111tttfttfiiffiifffififfiltiffillttiffflififf Dose Conversion Factor (and Related) Parameter Summary...
2 Site-Specific Parameter Summary............
3 Summary of Pathway Selections..............................
7 Contaminated Zone and Total Dose Summary.................
8 Total Dose Components Time = O.OOOE+00......................................
9 Time = 1.OO E+OO......................................
10 Time = 3.000E+00.....................................
11 Time = 1.00 8E+01.....................................
12 Time = 3.000E+01.....................................
13 Time = 1.000E+02.....................................
14 Time = 3.OOOE+02.....................................
15 Time = 1.000E+03 16 Dose/Source Ratios Summed Over All Pathways..............
17 Single Radionuclide Soil Guidelines.......................
17 Dose Per Nuclide Summed Over All Pathways.................
18 Soil Concentration Per Nuclide...........................
18 1RESRAD, Version 6.5 T; Limit = 30 days 11/27/2011 10:26 Page 2
Summary : HB soil DCGL_I129 File
- C:\\RESBADFAMILY\\RESRAD\\6.5\\USERFILES\\1129 DCGL\\HB SOIL DCGL_II29.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: HR DCGLs Plus FGR 12 & FGR 11 0
3 3 Current 3
Base Parameter Menu 3 Parameter value#
3 Case*
I Name A-1 DCF'S for external ground radiation, (mrem/yr)/(pCi/g)
A-1 1-129 (Source:
FGR 12) 1.295E-02 1.295E-02 DCF1(
1)
B-I Dose conversion factors for inhalation, mrem/pCi:
B-i 1-129 1.740E-04 I 1.740E-04 DCF2(
1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 1-129 2.760E-04 2.760E-04 DCF3(
1)
D-34 Food transfer factors:
D-34 1-129
, plant/soil concentration ratio, dimensionless 3.670E-02 2.000E-02 RTF(
1,1)
D-34 1-129 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.230E-02 7.OOOE-03 RTF(
1,2)
D-34 1-129 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.390E-02 1.000E-02 RTF(
1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 1-129
, fish 4.000E+01 4.OOOE+01 BIOFAC(
1,1)
D-5 i-129
. crustacea and mollusks I5.OOOE+00 5.000E+00 BIOFAC(
1 2)
- For DCF1(xxx) only, factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Default.Lib w/o Associate Nuclide contributions.
1RESRAD, Version 6.5 Ta Limit = 30 days 11/27/2011 10:26 Page 3
Summary : HB soil DCGL_I129 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\1129 DCGL\\HB SOIL DCGL-1129.RAD site-Specific Parameter Summary 0
3 user used by RESRAD 3 Parameter menu ParamFý eter Input....3 Default.. I.(.If di~ffe.re~nt.from user input)'I Name R011 Area of contaminated zone (m**2)
R011 Thickness of contaminated zone (m)
R011 3 Fraction of contamination that is submerged R011 Length parallel to aquifer flow (m)
Roll 3 Basic radiation dose limit (mrem/yr)
Roll 3 Time since placement of material (yr)
Roll Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
Roll Times for calculations (yr)
P011 Times for calculations (yr)
Roll 3 Times for calculations (yr)
Roll Times for calculations (yr)
R011 Times for calculations (yr)
R012 Initial principal radionuclide (pCi/g):
1-129 R012 Concentration in groundwater (pCi/L):
1-129 R013 Cover depth (m)
R013 Density of cover material (g/cm t m 3)
R013 Cover depth erosion rate (m/yr)
R013 Density of contaminated zone (g/cm m*3)
R013 Contaminated zone erosion rate (m/yr)
R013 Contaminated zone total porosity R013 Contaminated zone field capacity R013 Contaminated zone hydraulic conductivity (m/yr)
R013 Contaminated zone b parameter R013 Average annual wind speed (m/sec)
R013 3 Humidity in air (g/m**3)
R013 Evapotranspiration coefficient R013 Precipitation (m/yr)
R013 Irrigation (m/yr)
R013 Irrigation node R013 Runoff coefficient R013 watershed area for nearby stream or pond (m**2)
R013 Accuracy for water/soil computations R014 Density of saturated zone (g/cm t 3)
R014 Saturated zone total "porosity R014 Saturated zone effective porosity R014 Saturated zone field capacity R014 Saturated zone hydraulic conductivity (m/yr)
BA RTLETT 3.OOOE+04 1.000E+04 2.670E+00 2.000E+00 0.OOOE+00 0.OOOE+O0 1.950E+02 1.OOOE+02 2.500E+01 3.OOOE+01 O.OOOE+00 0.O00E+O0 3 1.000E+O0 3.OOOE+O0 33.oOOrE+O0 3.OOOE+00 1.000E+01 1,000E+01 3.000E+01 3.OOOE+01 1.000E+02 1.OO0E+02 3.000E+02 3.000E+02
- 1.000E+03 1.000E+03 I not used 30.000+00 not used O000OE+00 1.OO0E+O0 O.000E+00 not used 0.OO0E+00 0.0O0E+O0 O.OOOE+00 not used 1.500E+0O not used 1.OOOE-03 1.564E+00 1.500E+00 2.200E-03 1.000E-03 4.100E-01 4.000E-01 9.500E-02 2.000E-01 3.900E+00 1.000E+01 5.600E+00 5.300E+00 3.040E+00 2.000E+00 not used 8.OOOE+00 6.250E-01 5.OOOE-O1 9.100E-01 1.000E+00 5.600E-01 2.000E-01 overhead overhead 5.OOOE-01 2.OOOE-01 2,520E+07 1.000E+06 l.OOOE-03 1.OOOE-03 1.510E+00 1.500E+00 4.300E-01 4.000E-01 3.420E-01 2.00OE-01 8.800E-02 2.000E-01 2.880E+01 1.000E+02 AREA THICKO SUBMFRACT LCZPAQ 0BRDL 3 TI
' T(
2) 3 T( 3)
T(
4)
T( 5)
T( 6)
T(
7) 3 T( 8) 3 T( 9)
T(10)
SI(1)
Wl( 1)
COVERO DENSCV VCV DENSCZ VCZ TPCZ FCCZ HCCZ BCZ WIND HUMID EVAPTR PRECIP RI IOITCH RUNOFF WAREA EPS 3 DENSAQ TPSZ EPSZ FCSZ HCSZ Page 83
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R014 Saturated zone hydraulic gradient 2.OOOE-03 2.OOOE-02 R014 Saturated zone b parameter 7.100E+00 5.300E+00 R014 water table drop rate (m/yr) 1.OOOE-03 1.OOOE-03 R014 Well pump intake depth (m below water table) 1.OOOE+01 1.OOOE+01 R014 Model: Nondispersion (ND) or Mass-Balance (MB)
ND NO R014 well pumping rate (m**3/yr) 1.573E+03 2.5OOE+02 1RESRAD, version 6.5 T' Limit - 30 days 11/27/2011 10:26 Page 4
Summary : HB soil DCGL.I129 File
- C:\\RESRADOFAMILY\\RESRAO\\6.5\\uSERFILES\\129 DCGL\\HB SOIL DCGL_I129.RAD 0
3 menu 3Parameter R015 Number of unsaturated zone strata R015 Unsat. zone 1, thickness (m)
R015 unsat. zone 1, soil density (g/cm**
R015 Unsat. zone 1, total porosity R015 Unsat. zone 1, effective porosity R015 Unsat. zone 1, field capacity RO15 unsat. zone 1, soil-specific b para R015 unsat. zone 1, hydraulic conductivi R016 Distribution coefficients for 1-129 R016 Contaminated zone (cm**3/g)
R016 unsaturated zone 1 (cm**3/g)
R016 Saturated zone (cm**3/g)
R016 Leach rate (/yr)
R016 Solubility constant R017 inhalation rate (m**3/yr)
R017 Mass loading for inhalation (g/m**3 R017 Exposure duration R017 shielding factor, inhalation R017 Shielding factor, external gamma R017 Fraction of time spent indoors R017 Fraction of time spent outdoors (on R017 Shape factor flag, external gamma R017 Radii of shape factor array (used R017 Outer annular radius (m),
ring I
R017 Outer annular radius (m),
ring R017 Outer annular radius (m),
ring 3
R017 Outer annular radius (m),
ring 4
R017 Outer annular radius (m),
ring R017 Outer annular radius (m),
ring ROl7 Outer annular radius (m),
ring R017 Outer annular radius (m), ring 8
R017 Outer annular radius (m),
ring 9
R017 Outer annular radius (m),
ring 10 R017 Outer annular radius (m),
ring 11 R017 Outer annular radius (m),
riflg 12 Site-Specific Parameter Summary (continued) user 3
used by RESRAD I Input 3Default (if different from user
'1
'1--
4.040E+00 4.OOOE+00
- 3) 1.564E+00 1.500E+O0 4.10OE-Ol 4.OOOE-01 3.150E-01 2.OOOE-O1 9.500E-02 2.000E-01 meter 5.600E+00 5.300E+00
'ty (m/yr) 3.900E+00 1.000E+01 4.600E+00 1.OOOE-01 4.600E+00 1.OOOE-01 3 4.600E+00 1.OOOE-01
'.OOOE 0
O.OOOE+00 1.891E-02 0.0OOE+0O O.OOOE+00 not used 8.400E+03 8.400E+03
- 3) 1.000E-04 I.OOOE-04 3.OOOE+Ol 3.OOOE+OI 5.500E-01 4.000E-01 2.725E-01 7.000E-Ol 6.571E-01 5.00OE-Ol n site) 1.181E-OI 2.500E-01 1.00OE+O0 1.0OOE+0O
>0 shows circular ARE f FS= -):
3 3 not used 5.OOOE+Ol a
3 not used 7.071E+101 3 not used O.000E+00-3 not used O.OOOE+00
- not used 3.00E+O0---
I not used O.O0OE+O0-7 not used O.000E+00 3 not used 3O.00E+00 a 3 not used 0.000E+00 3 not used 0.000E+00-3 not used O.000E+00 3 not used O.006E+00 A
E BSZ VWT DWIBWT MODEL 3UW Parameter input)
Name 3 NS H(1)
DENSUZ(1)
' TPUZ(1)
EPUZ(1)
FCUZ(1)
BUZ(1)
HCUZ(1)
DCNUCC( 1)
DCNUCU( 1,1)
DCNUCS( 1)
ALEACH(
1)
SOLUBK(
1)
INHALR MLINH 3 ED SHF3 SHF1 FIND FOTD A.
3 S
' RADSHAPE(
1)
RADSHAPE(
2) 3 PAD.SHAPE(
3)
' RADSHAPE(
4) 3 RAD-SHAPE(
5)
RADOSHAPE( 6)
PRADSHAPE( 7)
RADSHAPE(
8)
RADSHAPE(
9)
RAD.SHAPE(10)
RAD.SHAPE(11)
RADSHAPE(12)
- IRESRAD, Version 6.5 T. Limit = 30 days 11/21/2011 10:26 Page 5
Summary : HE soil DCGL_I129 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\II29 DCGL\\HB SOIL DCGL_I129.RAD 0
3 Menu 3 Site-specific Parameter Summary (continued) 3 User ffused by RESRAD Parameter f..............
a.ult (If dierent rom user input)
.. Name AAAAAAAAAAAAAAAA
'AAAAAAAAAAAAAAAA AAAAAAAAAAA kAA R017 Fractions of annular areas within AREA:
ROl7 Ring 1
ROI7 Ring 2
R017 Ring 3
ROl7 Ring 4
ROl7 Ring 5
R017 Ring 6
ROl7 Ring 1
R017 Ring 8
R017 Ring 9
ROll Ring 10 R017 Ring 11 R017 Ring 12 R018 Fruits, vegetables and grain consumption (kg/yr)
R018 Leafy vegetable consumption (kg/yr)
R018 Milk consumption CL/yr)
R018 Meat and poultry consumption (kg/yr)
R018 Fish consumption (kg/yr)
R018 Other seafood consumption (kg/yr)
R018 soil ingestion rate (g/yr)
R018 Drinking water intake (L/yr)
RO18 contamination fraction of drinking water R018 Contamination fraction of household water R018 Contamination fraction of livestock water R018 Contamination fraction of irrigation water R018 Contamination fraction of aquatic food R018 Contamination fraction of plant food R018 Contamination fraction of meat R0,8 Contamination fraction of milk RO9 Livestock fodder intake for meat (kg/day)
R019 Livestock fodder intake for milk (kg/day)
R019 Livestock water intake for meat (L/day)
R019 Livestock water intake for milk (L/day)
R019 Livestock soil intake (kg/day)
R019 Mass loading for foliar deposition (g/m**3)
R019 Depth of soil mixing layer (m)
RO9 Depth of roots (m)
R019 Drinking water fraction from ground water R019 Household water fraction from ground water R019 Livestock water fraction from ground water R019 Irrigation fraction from groun water R198 wet weight crop yield for Non-Leafy (kg/m**2)
R198 Wet weight crop yield for Leafy (kg/m**2)
R19a wet weight crop yield for Fodder (kg/m**2)
R19B Growing Season for Non-Leafy (years)
RI9B Growing Season for Leafy (years)
R198 Growing Season for Fodder (years) t BARTLETT not used 1.000E+00 not used 2.732E-01 not used O.O00E+00 not used O.O0OE+O0 not used O.OOOE+00 a not used O.OOOE+00 not used O.OOOE+00 not used O.OOOE+00 a not used O.OOOE+00 not used 3 O.OOOE+00 not used O.O00E+00 not used O.0000E+0 1.120E+02 1.600E+02 2.140E+01 1.400E+01 2.330E+02 9.200E+01 6.510E+01 6.300E+01 2.060E+01 5.400E+00 9.000E-01 9.000E-01 1.826E+01 3.650E+01 4.785E+02 5.10OE+02 1.OOOE+O0 1.OOOE+O0 not used 1.000E+00 I.000E+00 1.000E+00 1.OOOE+00 1.O00E+O0 1.000E+00 5.OOOE-01 1.000E+00 '-1 1.OOOE+O0 '-1 1.000E+00
- -1 2.710E+01 I 6.800E+01 6.320E+01 5.500E+01 5.060E+01 3 5.000E+01 6.000E+01 1.600E+02 5.000E-01 ' 5.000E-01 4.000E-04 I.OOOE-04 2.300E-01 1.500E-01 1.220E+00 9.OOOE-Ol 1.OOE+00 1.O00E+00 not used 1.OOOE++/-0 1.OOOE+00 1.OOOE+O0 1.O00E+00 1.O00E+00 1.750E+00 7.OOOE-01 2.889E+03 1.500E+0O 1.887E+00 1.100E+00 2.460E-01 1.700E-01 I 1.230E-01 2.500E-01 8.200E-02 8.OOOE-02 FRACA( 1)
FRACAC 2)
FRACA(
3) 3 FRACA( 4)
' PRACA( 5) 3 FRACA( 6) 3 FRACA( 7)
FRACA( 8) 3 FRACAC 9) 3 FRACA(IO)
FRACA(II)
FRACA(12)
DIET(1)
DIET(2)
DIET(3)
DIET(4)
DIET(S)
DIET(6)
SOIL DWI FDW FHHW FLW 3 FIRW FR9 FPLANT FMEAT FMILK 3
3 3
3 3
3 3
LFI5 LFI6 LWl 5 LwI 6 LSI MLFD DM DROOT FGWDW FGWHH FGWLW FGWIR Yv(1)
Yv(2)
Yv(3)
TE(1)
TE(2)
TE(3)
Page 84
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 IRESRAD, Version 6.5 Tn Limit = 30 days 11/27/2011 10:26 Page 6
Summary : HB soil DCGL-1129 File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\I129 DCGL\\HB SOIL DCGL.1129.RAD site-Specific Parameter Summary (continued) 0 3
User 3
ffused by RESRAD Parameter Menu Parameter input 3Default (If different from user input) 3 Name W
R19B Translocation Factor for Non-Leafy 1.OOOE-01 1.O00E-O1 TIV(1)
Ri9B Translocation Factor for Leafy 1.OOOE00
- i.
OE00 TIV(2)
R19B Translocation Factor for Fodder 1.OOOE+00 1.000E+00 TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 3 2.500E-01 RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 I 2.50OE-01 RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 I 2.500E-01 3 RDRY(3)
R19B wet Foliar Interception Fraction for Non-Leafy 3.500E-01 3 2.500E-01 RWET(1)
R19B wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 RWET(2)
R19B 3 wet Foliar Interception Fraction for Fodder 3.SOOE-01 2.500E-01 RWET(3)
R19B weathering Removal Constant for Vegetation 3.300E+01 I 2.OOOE+01 WLAM C14 C-12 concentration in water (g/cm**3) not used 2.OOOE-05 C12WTR C14 C-12 concentration in contaminated soil (g/g) not used I 3.000E-02 C12CZ C14 Fraction of vegetation carbon from soil not used 3 2.OOOE-02 CSOIL C14 Fraction of vegetation carbon from air not used 3 9.800E-01 CAIR C14 3 C-14 evasion layer thickness in soil (m) not used
' 3.OOOE-01 DMC C14 C-14 evasion flux rate from soil (1/sec) not used 3 7.OOOE-07 EVSN C14 C-12 evasion flux rate from soil (1/sec).
not used 1.000E-0 REVSN C14 Fraction of grain in beef cattle feed not used I 8.OOOE-01 AVFG4 C14 Fraction of grain in milk cow feed not used I 2.000E-01 AVFG5 STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 I 1.400E+O1 STORT(1)
STOR Leafy vegetables 1.000E+00 1
1.OOOE+00 STORT(2)
STOR Milk 1.000E+00 I 1.000E+00 STORT(3)
STOR Meat and poultry 2.000E+01 I 2.O0OE+01 STOR.T(4)
STOR Fish 7.000E+00 I 7.000E+00 STORT(5)
STOR Crustacea and mollusks 7.000E+00 I 7.OOOE+00 STORT(6)
STOR well water 1.000E+00 I1.000E+00 STORT(7)
STOR Surface water 1.000E+00 1.OOOE+00 STORT(8)
STOR Livestock fodder 4.500E+01 4.500E+01-STORT(9)
R021 Thickness of building foundation (m) not used I 1.500E-01 FLOORI R021 Bulk density of building foundation (g/cm**3) not used 3 2.400E+00 DENSFL R021 Total porosity of the cover material not used I 4.000E-01 TPCV R021 Total porosity of the building foundation not used 3 1.OOOE-01 TPFL R021 Volumetric water content of the cover material not used 3 5.OOOE-02 PH2OCV R021 Volumetric water content of the foundation not used
- 3.OOOE-02 PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used I 2.000E-06 DIFCV R021 in foundation material not used I 3.OOOE-07 DIFFL R021 in contaminated zone soil not used I 2.OOOE-06 DIFCZ R021 Radon vertical dimension of mixing (m) not used 3 2.000E+00 HMIX R021 Average building air exchange rate (1/hr) not used 5.00OE-01 REXG R021 Height of the building (room)
(m) not used 3 2.50OE+00 HRM R021 Building interior area factor not used 3 0.000E+00 FAI R021 Building depth below ground surface (m) not used 3-1.00OE+00 DMFL R021 Emanating power of Rn-222 gas not used 3 2.500E-01 EMANA(1)
R021 Emanating power of Rn-220 gas not used
- 1.500E-01 EMANA(2)
TITL Number of graphical time points 3?32 3
NPTS
- 1RESRAD, Version 6.5 Taý Limit = 30 days 11/27/2011 10:26 Page 7
Summary : HB soil DCGL_II29 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\1129 DCGL\\HB SOIL DCGLI129.RAD site-Specific Parameter Summary (continued) 0 user used by RESRAD Parameter Menu 3 Parameter 3.input 3.Default (if di.fferent from user input) 3.Name A...
TITL ' Maximum number of integration points for dose 17 3
LYMAX TITL 3 Maximum number of integration points for risk 1
KYMAX Summary of Pathway Selections Pathway User Selection external gamma active 2 inhalation (w/o radon) 3 active 3-- plant ingestion active 4
meat ingestion active 5
milk ingestion active 6
aquatic foods active 7
drinking water active 8
soil ingestion active 9 --
radon suppressed Find peak pathway doses active Itittlitfitllflttlfiittilflltlitttlttttilitililiftt IRESRAD, Version 6.5 T-Limit = 30 days 11/27/2011 10:26 Page 8
Summary : HB soil DCGL1129 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\II29 DCGL\\HB SOIL DCGLI129.RAD Contaminated Zone Dimensions Initial Soil Concentrations,...c/g Area:
30000.00 square meters 1-129 1.000E+00 Thickness:
2.67 meters Cover Depth:
0.00 meters IRESRAD, Version 6.5 Ta Limit = 30 days 11/27/2011 10:26 Page 1
Probabilistic results summary : HB soil DCGLsIl29 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\1129 DCGL\\HB SOIL DCGL-I129.RAD Table of Contents AXAAXSXXAXXAAAAAA Part VI: Uncertainty Analysis ffiittltfitttittlifftitiizlt ORESRAD uncertainty Analysis Results Probabilistic Input..
2 Total Dose...........................................
3 Total Risk..
4 Dose vs Pathway:
Ground External...................
5 (B
AARTLETT Page.8 5
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Dose vs Pathway:
Inhalation (w/o Radon) 6 Dose vs Pathway:
Radon (water Ind.)
7 Dose vs Pathway:
Plant (Water Ind.)................
8 Dose vs Pathway:
Meat (water Ind.)................
9 Dose vs Pathway:
Milk (Water Ind.)................
10 Dose vs Pathway:
Soil Ingestion.....................
11 Dose vs Pathway:
water Ingestion....................
12 Dose vs Pathway:
Fish Ingestion....................
13 Dose vs Pathway:
Radon (Water Dep.).................
14 Dose vs Pathway:
Plant (Water Dep.)................
15 Dose vs Pathway:
Meat (Water Dep.)
16 Dose vs Pathway:
Milk (Water Dep.)
17 Cumulative Probahility summary.......................
18 Summary of dose at graphical times, reptition 1...
19 Peak of the mean dose at graphical times.............
20 Correlation and Regression coefficients (if any).....
21 IRESRAD, Version 6.5 Ta Limit = 30 days 11/27/2011 10:26 Page 2
Probabilistic results summary : HB soil DCGLI129 File : C:\\RESRAD-FAMILY\\RESRAD\\6.5\\USERFILES\\129 DCGL\\HB SOIL DCGLI129.RAD Probabilistic Input ONumber of Sample Runs: 2000 Number 1
2 3
45 6
7 8
9 10 11 12.
13 14 15 16 17 18 19 20
.00003 21 22 23 24 25 26 27 28 29 30 f"lift Name DENSCZ TPCZ HCCZ BCZ EVAPTR RI DENSAQ TPSZ EPSZ HCSZ BSZ DWIBR*
UW H (1)
DENSUZ(1)
TPUZ(1)
EPUZ(1)
HCUZ(1)
BUZ(1)
MLINH
.8119 SHF3 SHF1 DM YV(1)
WLAM RWET(2)
DCACTC(1)
DCACTU1(1)
DCACTS(1)
BBIO(53,1)
Itilttttif Distribution Parameters BOUNDED NORMAL 1.5635
.2385
.827 2.3 BOUNDED NORMAL
.41
.09
.1319
.6881 BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 UNIFORM
.5
.75 UNIFORM
.36
.76 BOUNDED NORMAL 1.5105
.1855
.937 2.084 BOUNDED NORMAL
.43
.0699
.214
.646 BOUNDED NORMAL
.342
.0705
.124
.56 BOUNDED LOGNORMAL-N.362 1.59
.0106 195 BOUNDED LOGNORMAL-N 1.96
.265 3.02 15.5 TRIANGULAR 6
10 30 UNIFORM 1173 1973 UNIFORM 0
8.08 BOUNDED NORMAL 1.5635
.2385
.827 2.3 BOUNDED NORMAL
.41
.09
.1319
.6881 BOUNDED NORMAL
.315
.0905
.0349
.594 BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 CONTINUOUS LINEAR 8
0 0
.000008
.00004
.9495
.00006
.9937
.000076
.9983
.0001 1
UNIFORM
.1s
.95 BOUNDED LOGNORMAL-N -1.3
.59
.044 1
TRIANGULAR 0
.15
.6 TRUNCATED LOGNORMAL-N.56
.48
.001
.999 TRIANGULAR 5.1 18 84 TRIANGULAR
.06
.67
.95 TRUNCATED LOGNORMAL-N 1.52 2.19
.001
.999 TRUNCATED LOGNORMAL-N 1.52 2.19
.001
.999 TRUNCATED LOGNORMAL-N 1.52 2.19
.001
.999 LOGNORMAL-N 3.7 1.1 ttifttttiftt ttiltitifffttttttNtItt 3.7lI
.1tttfttt ftfttttttftilttittiftflt 0151
.000016
.1365 IRESRAD, Version 6.5 T" Limit = 30 days 11/27/2011 10:26 Page 20 Probabilistic results summary : HB soil DCGLI129 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\II29 DCGL\\HB SOIL DCGLI129.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1
O.OOOE+00 5.174E+00 I^- BARTLIETT Page 86
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Nb-94 Results:
1RESRAD, Version 6.5 T. Limit = 30 days 11/28/2011 09:27 Page I
Summary : HB soil DCGLCNb-94 File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NB94 DCGL\\HB SOIL DCGLJNB94.RAD Table of Contents Part I: Mixture SuMs and Sinqle Radionuclide Guidelines tffittttj tltttt11tt11tltttjffftf f
liftfiffffi tlffffff Dose Conversion Factor (and Related) Parameter Summary...
2 Site-Specific Parameter Summary..........................
3 Summary of Pathway Selections............................
7 Contaminated Zone and Total Dose Summary.................
8 Total Dose Components Time = O.OOOE+O0......................................
9 Time = 1.OOOE+00....................................
.10 Time = 3.000E+0O 11 Time = 1.000E+01.....................................
12 Time = 3.000E+01.....................................
13 Time = 1.000E+02.....................................
14 Time = 3.OOO +02.
15 Time = 1.000E+03....................................
16 Dose/Source Ratios Summed Over All Pathways..............
17 Single Radionuclide Soil Guidelines......................
17 Dose Per Nuclide Summed Over All Pathways.................
18 Soil Concentration Per Nuclide 18 IRESRAD, Version 6.5 T" Limit = 30 days ii/28/2011 09:27 Page 2
Summary : HB soil DCGLNb-94 File
- C:\\RESRAD-FAMILY\\RESRAD\\6.5\\USERFILES\\NB94 DCGL\\HB SOIL DCGLJB94.RAD 0
3 Menu Dose Conversion Factor (and Related) Parameter Summary Dose Library: HB DCGLs Plus FGR 12 & FGR 11 3 Current 3
Base Parama et y3
.value#
3 Case*
Parameter Name A-1 DCF's for external ground radiation, (mrem/yr)/(pCi/g)
A-1 Nb-94 (Source:
FGR 12) 9.677E+00 9.677E+00 DCF1(
1)
B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Nb-94 4.140E-04 3 4.140E-04 DCF2(
1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Nb-94 7.140E-06 7.140E-06 DCF3(
1)
D-34 Food transfer factors:
D-34 Nb-94
, plant/soil concentration ratio, dimensionless 1.000E-02 1.OOOE-02 RTF(
1,1)
D-34 Nb-94 beef/livestock-intake ratio, (pci/kg)/(pCi/d) 3.O0OE-07 3.OOOE-07 RTF(
1,2)
D-34 Nb-94 milk/livestock-intake ratio, (pci/L /(pci/d) 2.000E-06 2.000E-06 RTF(
1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Nb-94
, fish 3.000E+02 3.OOO+02 BIOFAC(
1,1)
D-5 Nb-94
, crustacea and mollusks 1.OOOE+02 1.OOOE+02 ' BIOFAC(
1 2)
- For DCF1(xxx) only, factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
"Base Case means Default.Lib w/o Associate Nuclide contributions.
1RESRAD, Version 6.5 Tx Limit = 30 days 11/28/2011 09:27 Page 3
Summary : HB soil DCGL_Nb-94 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NB94 DCGL\\HB SOIL DCGLNB94.RAD 0
3 menu I.Prameter ROll ' Area of contaminated zone (m**2)
RO11 Thickness of contaminated zone (m)
ROll 3 Fraction of contamination that is submer RO11 Length parallel to aquifer flow (m)
RO11 3 Basic radiation dose limit (mrem/yr)
R011 Time since placement of material (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
RO11 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R012 Initial principal radionuclide (pCi/g):
R012 Concentration in groundwater (pci/L):
R013 Cover depth (m)
R013 Density of cover material (g/cm"3)
R013 Cover depth erosion rate (m/yr)
R013 Density of contaminated zone (g/cm**3)
R013 Contaminated zone erosion rate (m/yr)
R013 contaminated zone total porosity R013 contaminated zone field capacity R013 contaminated zone hydraulic conductivity R013 contaminated zone b parameter R013 Average annual wind speed (m/sec)
R013 Humidity in air (g/m**3)
R013 Evapotranspiration coefficient R013 Precipitation (m/yr)
ROl3 Irrigation (m/yr)
R013 Irrigation mode R013 Runoff coefficient R013 watershed area for nearby stream or pond R013 Accuracy for water/soil computations R014 Density of saturated zone (g/cm*"3)
R014 Saturated zone total porosity R014 Saturated zone effective porosity R014 Saturated zone field capacity R014 Saturated zone hydraulic conductivity (m/
So BARTLETT Site-specific Parameter Summary User 3
used by RESRAD 3 Parameter Input
' Default (if different..from user input)
Name 3.000E+04 1.OOO+04 AREA 1.830E+00 2.OOOE+00 THICKO ged 0.OOOE+00 0.OOOE+00 SUBMFRACT 1.950E+02 1.OOOE+02 3 LCZPAQ 2.500++01 3.OOOE+01 BRDL O.000E+O0 O.OOOE+00 TI 1.000E+00 1.O00E+0O T(
2) 3.OOOE+00-3.OOOE+00 T(
3) 1.000E+01 1.0005+01 T(
4) 3.OOE+01 3.OOOE+01 T(
5) 1.OOOE+02 1.OOOE+02 T( 6) 3 3.OOOE+02 I 3.OOOE+02 I T( 7)
' 1.OQOE+03 1.OOO+03 T( 8) not used 0.OOOE+00 T( 9) not used O.OOOE+00 T(10)
Nb-94 l.OO00E+00 0.OOO+00 SI(l)
Nb-94 not used O.00E+O0 Wl( 1)
O.OOOE+00 O.O0OE+O0 COVERO not used 1.500E+0O DENSCV I not used 1.000E-03I VCV 1.564E+00 1.500E+00 DENSCZ I 2.200E-03 1.OOO-03 VCZ 4.100E-01 4.OOOE-01 TPCZ 9.500E-02 2.OOOE-01 "FCCZ (m/yr) 3,900E+00 1.O0OE+O1 HCCZ 5.600E+00 5.300E+00 BCZ 3.040E+00 2.OOO+00 WIND not used 8.OOOE+00 HUMID 6.250E-01 S.OOOE-01 EVAPTR 9.100E-01 1.000E+O0 PRECIP 5.600E-01 2.00OE-01 RI overhead overhead IDITCH 5.0005-01 2.OOOE-01 RUNOFF (m*"2) 2.520E+07 1.OOOE+06 I WAREA 1.000E-03 l.OOOE-03 EPS 1.510E+00 1.500E+00 3--
DENSAQ 4.300E-01 4.000E-01 TPSZ 3.420E-01 2.000_-01 3 EPSZ 8.800E-02 2.OOOE-01 FCSZ
/yr) 2.880E+01 1.000E+02 HCSZ Page 87
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R014 saturated zone hydraulic gradient 2.OO0E-03 2.OOOE-02 R014 Saturated zone b parameter 7.100E+00 5.300E+00 R014 W
water table drop rate (m/yr) 1.000E-03 1.O00E-03 R014 3 Well pump intake depth (m below water table) 1.OOOE+01 1.000E+O1 R014 3 Model: Nondispersion (ND) or Mass-Balance (MB)
ND ND R014 ' well pumping rate (m**3/yr) 1.573E+03 2.SOOE+02 3
- 1RESRAD, version 6.5 T1 Limit = 30 days 11/28/2011 09:27 Page 4
Summary : HB soil DCGLNb-94 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\NB94 DCGL\\HB SOIL DCGL.JB94.RAD Site-Specific Parameter Summary (continued) 0 3
3 User a
Menu I Parameter I
input 3.Defaul.t 3 (If R015 Number of unsaturated zone strata 1
1 R015 Unsat. zone 1, thickness (m) 4.040E+00 4.OB00E+O R015 Unsat. zone 1, soil density (g/cm**3) 1.564E+00 3 1.5OOE+00 R015 a Unsat. zone 1, total porosity 4.100E-O1 4.OOOE-01 ROS Unsat. zone 1, effective porosity 3.15OE-01 2.000E-_01 R015 Unsat. zone 1, field capacity 9.500E-02 I 2.OOOE-01 R015 a Unsat. zone 1, soil-specific b parameter 5.600E+00 5.300E+00 R01S Unsat. zone 1, hydraulic conductivity (m/yr) 3.900E+00 1.OOOE+01 R016 Distribution coefficients for Nb-94 R016 Contaminated zone (cma*3/g) 3.560E+03 O.OOE+00 RO16 Unsaturated zone 1 (cm**3/g) 3.800E+02 O.OOOE+O0 RO16 Saturated zone (cm**3/g) 3.800E+02 O.OOOE+00 R016 a Leach rate (/yr) 0.OOOE+0O O.OOOE+00 R016 a solubility constant O.OOOE+00 O.OOOE+O0 R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 R017 Mass loading for inhalation (g/m**3) 1.OOOE-04 a 1.000E-04 R017 Exposure duration 3.OOoE+01 3.OOOE+01 R017 Shielding factor, inhalation 5.500E-01 4.OOOE-01 R017 Shielding factor, external gamma 3.980E-01 7.00DE-01 ROll Fraction of time spent indoors 6.571E-01 S.OOOE-01 R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 R017 Shape factor flag, external gamma 1.OOOE+O0 I.OOOE+00 R017 Radii of shape factor array (used if FS = -1):
a se R017 Outer annular radius (m),
ring 1:
not used 5.OOOE+01 ROl7 Outer annular radius (m),
ring 2:
not used 7.071E+01 R017 Outer annular radius Cm), ring 3:
not used O.O0E+OO R017 Outer annular radius (m),
ring 4:
not used O.O00E+OO R017 Outer annular radius (m),
ring 5:
not used O.OOOE+OO R017 Outer annular radius (m),
ring 6:
not used O.OOOE+00 R017 Outer annular radius (m),
ring 7:
a not used O.OOOE+O0 ROll Outer annular radius (m),
ring 8:
not used O.OOE+O0 R017 Outer annular radius (m),
ring 9:
not used O.OOOE+0O R017 Outer annular radius (m),
ring 10:
not used O.OOOE+0O R017 Outer annular radius (m),
ring 10:
not used O.OO0E+O0 R017 Outer annular radius (m),
ring 12:
not used O.OOOE+00 1RESRAD, version 6.5 T. Limit = 30 days 11/28/2011 09:27 Page 5
Summary : HB soil DCGLNb-94 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NB94 DCGL\\HB SOIL DCGL_NB94.RAD Site-Specific Parameter Summary (continued) 0 User 3
men U 3
Parameter a
Input 3Default a (If HGWT BSZ V*Fr DWIBWT MODEL UW used by RESRAD Parameter different from user input) a Name 3 NS a-DENSUZ(1)
TPUZ(1)
-- EPUZ(1) a FCUZ(1)
I BUZ(1) 3 HCUZ(1)
-- DCNUCC(
1) 3 DCNUCU( 1,1) 3 DCNUCS(
1) 3.737E-05 ALEACH(
1) not used SOLUBK(
1) a-INHALR MLINH 3 ED 3 SHF3 SHF1 FIND FOTD
>0 shows circular AREA.
FS RADtSHAPE(
1) 3 RAD-SHAPE(
2) 3 RADSHAPE(
3)
- RADSHAPE(
4)
RAD.SHAPE(
5)
RADSHAPE(
6)
RAD_SHAPE(
7) a RADSHAPE(
8)
RADSHAPE(
9)
-RADSHAPE(10) a RADSHAPE(11) 3 RADSHAPE(12) used by RESRAD a
Parameter R017 Fractions of annular areas within AREA:
R017 3 Ring 1
ROl7 Ring 2
R017 Ring 3
ROl7 Ring 4
R017 Ring S
R017 Ring 6
ROll Ring 7
R017 Ring 8
R017 Ring 9
R017 Ring 10 R017 Ring 11 R017 Ring 12 R018 Fruits, vegetables and grain consumption (kg/yr)
R018 Leafy vegetable consumption (kg/yr)
R018 Milk consumption (L/yr)
R018 Meat and poultry consumption (kg/yr)
RO18 Fish consumption (kg/yr)
R018 Other seafood consumption (kg/yr)
RO8 soil ingestion rate (g/yr)
R018 Drinking water intake (L/yr)
R018 Contamination fraction of drinking water R018 Contamination fraction of household water R018 Contamination fraction of livestock water RO8 Contamination fraction of irrigation water R018 Contamination fraction of aquatic food R018 Contamination fraction of plant food R018 Contamination fraction of meat R018 Contamination fraction of milk R019 Livestock fodder intake for meat (kg/day)
R019 Livestock fodder intake for milk (kg/day)
R019 Livestock water intake for meat (L/day)
R019 3 Livestock water intake for milk (L/day)
R019 Livestock soil intake (kg/day)
R019 Mass loadinm for foliar deposition (g/m**3)
R019 Depth of soil mixing layer (m)
RO9I Depth of roots (m)
R019 Drinking water traction from ground water R019 Household water fraction from ground water ROI9 Livestock water fraction from ground water R019 Irrigation fraction from ground water R19B wet weight crop yield for Non-Leafy (kg/m**2)
R19B wet weight crop yield for Leafy (kg/m*a2)
Ri1B wet weight crop yield for Fodder (kg/m**2)
R19B a Growing Season for Non-Leafy (years)
R19B Growing Season for Leafy (years)
R19B Growing Season for Fodder (years)
L DARTLETT a not used a 1.OOOE+00 not used 2.732E-01 not used O.OOE+00 not used a O.OOOE+OO not used 0.OOOE+0O not used 0,OOOE+0O not used O.OO0E+00 3 not used O.OOOE+00- 3 not used O.0OOE+0O not used 3O.OO0E+003 not used 0.OOOE+OO3 a not used a 0.OOOE+OO 1.120E+02 1.600E+02 2.140E+01 1.400E+01 2.330E+02 9.200E+01 6.510E+01 6.300E+01 2.060E+01 a 5.400E+00 9.000E-O0 9.OOOE-O1 1.826E+01 I 3.650E+01 a 4.785E+02 a 5.100E+02 3 1.OOOE+0O 1.OOOE+0O a not used 1.OOOE+00 a 1.OOOE4+00 a 1.000E+00 a 1.0O0E+OO 1.OOOE+00 1.OOOE+OO S.OOOE-01 1.OOOE4+00 '-1 1.OO0E+OO '-I 1.OOOE+OO 3-I 2.710E+01 6.800E+01 a 6.320E+01 3 5.SOOE+01 s 5.060E+O1 5.OOOE+O1 6.OOOE+O1 1.600E+02 S.OOOE-01 5.000E-01 4.OOOE-04 1.000E-04 3 2.300E-01 1.50OE-O1 2.1SOE+00 9.OOOE-01 1.OO0E+O0 1.OOOE+00 a not used a 1.000E+00 1.000E+00 ' 1.OOOE+OO 1.OOOE+O0 1.OOOE+00 1.7SOE+00 7.OOOE-01
- 2.889E+00 1.500E+00
- 1.
87E+00 1.100E+00 2.460E-01 1.700E-01 1.230E-01 2.500E-01 B.2OOP-fl?
R.DOOF-Ol FRACA( 1)
FRACA( 2)
FRACAC 3)
FRACA( 4)
FRACAC 5)
FRACAC 6) 3 FRACA(
7)
FRACA( 8)
FRACA( 9)
FRACA(10)
FRACA(11)
FRACA(12)
DIET(1)
DIET(2) a DIET(3) 3 DIET(4)
DIET(S) a DIET(6)
SOIL 3DWI 3 FDW 3FHHW FLW a FIRW 3FR9 3 FPLANT 3 FMEAT FMILK LFI5 LFI6 LWI5 LW16 LSI a MLFD 3 DM DROOT FGWDW FGWHH FGWLW FGWIR YV(1)
YV(2)
Yv(3) 3 TE(1)
TE(2) 3 TF(q)
Page 88
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 IRESRAD, Version 6.5 Tý Limit = 30 days 11/28/2011 09:27 Page 6
Summary HB soil DCGLNb-94 File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NB94 DCGL\\HB SOIL DCGLNB94.RAD Site-Specific Parameter Summary (continued) 0 3
User u
used by RESRAD Parameter Menu
-Parameter Input Default
(*.
if different rom user input)
N Name R19B Translocation Factor for Non-Leafy 1.00E-01 O1.O0E-01 TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 TIV(2)
RI9B Translocation Factor for Fodder 1.000E+00 1.000E+00 TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 I RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3 3.500E-01 2.500E-01 RDRY(2)
RI9B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.50OE-01 RWET(2)
R19i Wet Foliar Interception Fraction for Fodder I 3.500E-01 2.500E-01 RWET(3)
R19B weathering Removal Constant for Vegetation 3.300E+01 2.OOOE01 WLAM c14 C-12 concentration in water (g/cm**3) not used 2.OOOE-05 C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000-E02 Cl2cz C14 Fraction of vegetation carbon from soil not used 2.000E-02 CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.OOoE-01 DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000-E10 REVSN C14 Fraction of grain in beef cattle feed not used 8.000E_01 AVFG4 C14 Fraction of grain in milk cow feed not used 2.OOOE-01 AVFG5 STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 STOR.T(1)
STOR Leafy vegetables 1.000E+00 1.000E+O0 STORT(2)
STOR Milk 1.000E+00 I1.000E+00 STORT(3)
STOR Meat and poultry 2.000E+O1 2.OO0E+01 STORT(4)
STOR Fish 7.000E+00 7.OO 0
STORIT(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 STORT(6)
STOR Well water 1.0000E+0 1.000E+00 STORT(7)
STOR surface water 1.000E+00 1.000E+00 STORT(8)
STOR Livestock fodder 4.500E+01 4.500E+01 STORT(9)
R021 Thickness of building foundation (m) not used 1.500E-01 FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 DENSFL R021 Total porosity of the cover material not used 4.000E-01 TPCV R021 Total porosity of the building foundation not used 1.000E-01 TPFL R021 volumetric water content of the cover material not used 5.000E-02 PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 DIFCV R021 in foundation material not used 3.000E-07 DIFFL R021 in contaminated zone soil 3 not used 2.000E-06 DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 HMIX R021 Average building air exchange rate (1/hr) not used 5.OOOE-01 REXG R021 3 Height of the building (room)
(m) not used 2.5OOE+00 HRM R021 3 Building interior area factor not used 0.000E+00 FAI R021 3 Building depth below ground surface (m) not used 3-1.000E+00 DMFL R021 3 Emanating power of Rn-222 gas not used 3 2.500E-01 EMANA(1)
R021 Emanating power of Rn-220 gas not used
- 1.500E-01 EMANA(2)
TITL ' Number of graphical time points 32 3
NPTS 1RESRAD, Version 6.5 Tc' Limit = 30 days 11/28/2011 09:27 Page 7
Summary : HB soil DCGL.Nb-94 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NB94 DCGL\\HB SOIL DCGLNB94.RAD Site-Specific Parameter Summary (continued) 0 3
User ffused by RESRAD 3 Parameter Menu I Parameter I input Default (i different from User inp.ut) 3 Name TITL Maximum number of integration points for dose 17 A--
LYMAX TITL Maximum number of integration points for risk 1
KYMAX TflL Maimum number oiffftf intter tfion points forisk 1
KYMAXfiftiitlffifffiftiffiffffff Summary of Pathway Selections P t w y.............
.... '..user Selection 1-- external gamma active 2
inhalation (w/o radon) 3 active 3 -- plant ingestion active 4
meat ingestion active 5
milk ingestion active 6
aquatic foods active 7-drinking water active 8
soil ingestion active 9 --
radon suppressed Find peak pathway doses I
active ffifif iff iiiitillffffitfitffifiiiftlffffiftiilfff
- IRESRAD, Version 6.5 T" Limit = 30 days 11/28/2011 09:27 Page 8
Summary : HB soil DCGLNb-94 File
- C:\\RESRADSFAMILY\\RESRAD\\6.5\\USERFILES\\NB94 DCGL\\HB SOIL DCGLNB94.RAD Contaminated Zone Dimensions Initial Soil Concentrations,..-.ci/g Area:
30000.00 square meters Nb-94 1.000E+00 Thickness:
1.83 meters Cover Depth:
0.00 meters IRESRAD, Version 6.5 TA Limit = 30 days 11/28/2011 09:27 Page 1
Probabilistic results summary : HB soil DCGLNb-94 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NB94 DCGL\\HB SOIL DCGLNB94.RAD Table of Contents Part VI: Uncertainty Analysis iftt, tltttlttttttifitttflti ORESRAD Uncertainty Analysis Results Probabilistic Input..
2 Total Dose..
3
,B ARTLETT Page 89
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Total Risk............................................
4 Dose vs Pathway:
Ground External...................
S Dose vs Pathway:
Inhalation (w/o Radon) 6 Dose vs Pathway:
Radon (Water Ind.)................
7 Dose vs Pathway:
Plant (Water Ind.)'.................
8 Dose vs Pathway:
Meat (Water Ind.);...................
9 Dose vs Pathway:
Milk (Water Ind.)................
10 Dose vs Pathway:
soil Ingestion.....................
11 Dose vs Pathway:
Water Ingestion...................
12 Dose vs Pathway:
Fish Ingestion....................
13 Dose vs Pathway:
Radon (Water Dep.).................
14 Dose vs Pathway:
Plant (Water Dep.).................
15 Dose vs Pathway:
Meat (Water Dep.)
16 Dose vs Pathway:
Milk (Water Dep.)
17 Cumulative Probability Summary.......................
18 Sumnary of dose at graphical times, reptition 1...
19 Peak of the mean dose at graphical times.............
20 Correlation and Regression coefficients (if any).....
21 1RESRAD, Version 6.5 T< Limit = 30 days 11/28/2011 09:27 Page 2
Probabilistic results summary : HB soil DCGLNb-94 File : C:\\RESR.AD.FAMILY\\RESRAD\\6.5\\USERFILES\\NB94 DCGL\\HB SOIL DCGL-NB94.RAD Probabilistic Input ONumber of Sample Runs: 2000 Number 1
2 3
45 6
7 8
9 10 11 12 13 14 15 16 17 18 19 20 21
.00003 22 23 24 25 26 27 28 29 30 31 32 33 l1t+/-tt Name Distribution THICKO UNIFORM DENSCZ BOUNDED NORMAL TPCZ BOUNDED NORMAL HCCZ BOUNDED LOGNORMAL-N BCZ BOUNDED LOGNORMAL-N EVAPTR UNIFORM RI UNIFORM DENSAQ BOUNDED NORMAL TPSZ BOUNDED NORMAL EPSZ BOUNDED NORMAL HCSZ BOUNDED LOGNORMAL-N BSZ BOUNDED LOCNORMAL-N DWIBWT TRIANGULAR UW UNIFORM H(1)
UNIFORM DENSUZ(1)
BOUNDED NORMAL TPUZ(1)
BOUNDED NORMAL EPUZ(1)
BOUNDED NORMAL HCUZ(1)
BOUNDED LOGNORMAL-N BUZ(1)
BOUNDED LOGNORMAL-N MLINH CONTINUOUS LINEAR
.8119
.00004
.9495
.00006
.9937 SHF3 UNIFORM DM TRIANGULAR DROOT UNIFORM YV(1)
TRUNCATED LOGNORMAL-N WLAM TRIANGULAR RWET(2)
TRIANGULAR DCACTUI(1)
TRUNCATED LOGNORMAL-N DCACTS(1)
TRUNCATED LOGNORMAL-N BRTF(41,1)
TRUNCATED LOGNORMAL-N BRTF(41,2)
TRUNCATED LOGNORMAL-N BRTF(41,3)
TRUNCATED LOGNORMAL-N BBIO(41,1)
LOGNORMAL-N ff1fttftttfttttittttfI tIffftflttIftiftlttiff Parameters
.15 1.5635
.41 1.36 1.73
.5
.36 1.5105
.43
.342
.362 1.96 6
1173 0
1.5635
.41
.315 1.36 1.73 8.000076 3.51
.2385
.827 2.3
.09
.1319
.6881 2.17
.00478 3190
.323 2.08 15.3
.75
.76
.1855
.937 2.084
.0699
.214
.646
.0705
.124
.56 1.59
.0106 195
.265 3.02 15.5 10 30 1973 8.08
.2385
.827 2.3
.09
.1319
.6881
.0905
.0349
.594 2.17
.00478 3190
.323 2.08 15.3 0
0
.000008
.9983
.0001 1
.0151
.000016
.1365
.15
.95 0
.15
.6
.3 4
.56
.48
.001
.999 5.1 18 84
.06
.67
.95 5.94 3.22
.001
.999 5.94 3.22
.001
.999
-4.61 1.1
.001
.999
-13.82
.9
.001
.999
-13.12
.7
.001
.999 5.7 1.1 ffifftlfttftttlfilffftttittftffttftttitt IRESRAD, Version 6.5 T<" Limit = 30 days 11/28/2011 09:27 Page 20 Probabilistic results summary : HB soil DCGL-Nb-94 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NB94 DCGL\\HB SOIL DCGLNB94.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1
0.OOOE+00 3.505E+00 (AaRTLaTT Page 90
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0.
Ni-59 Results:
- IRESRAD, version 6.5 To Limit = 30 days 11/28/2011 10:28 Page 1
Summary : HB soil DCGLNi-59 File C:\\RESRAD.FAMILY\\RESRAD\\6.5\\USERFILES\\NI59 DCGL\\HB SOIL DCGLNIS9.RAD Table of Contents Part I: Mixture SUMS and Sinale Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary...
2 site-Specific Parameter Summary..........................
3 Summary of Pathway Selections..............................
7 Contaminated Zone and Total Dose Summary...................
8 Total Dose Components Time = O.OOOE+00..
9 Time = 1.000E+00.....................................
10 Time 3.000E+0.....................................
11 Time 1.O00 E+01.
12 Time = 3.000E+01.
13 Time 1.000E+02.
14 Time = 3.000E+02.
1s Time = 1.000E+03....................................
16 Dose/Source Ratios Summed Over All Pathways..............
17 Single Radionuclide Soil Guidelines.......................
17 Dose Per Nuclide Summed over All Pathways................
18 Soil Concentration Per Nuclide...........................
18 IRESRAD, version 6.5 To Limit = 30 days 11/28/2011 10:28 Page 2
Summary : HB soil DCGL_Ni-59 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NI59 DCGL\\HB SOIL DCGLNIS9.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: HB DCGLs Plus FGR 12 & FGR 11 0
3 Current 3
Base 3
Parameter Menu 3Parameter value#
4 Case*
3 Name A-1 DCF's for external ground radiation, (mrem/yr)/(pCi/g)
A-1 Ni-59 (Source:
FGR 12)
O.O00E+0u 0.0OOE+O0 DCFI(
1)
B-1 Dose conversion factors for inhalation, mrem/pCi:
B-I Ni-59 2.700E-06 2.700E-06 DCF2(
1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Ni-59 2.100E-07 2.100E-07 DCF3(
1)
D-34 Food transfer factors:
D-34 Ni-59
, plant/soil concentration ratio, dimensionless 9.120E-02 5.OOOE-02 RTF(
1,1)
D-34 Ni-59 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.000E-03 5.000E-03 RTF(
1,2)
D-34 Ni-59 milk/livestock-intake ratio. (pCi/L)/(pCi/d) 3.210E-02 2.000E-02 RTF(
1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Ni-59
, fish 1.O00E+02 1.000E+02 BIOFAC(
1,1)
D-5 Ni-59
. crustacea and mollusks 1.O00E+02 1.000E+02 BIOFAC(
1 2)
- For DCF1(xxx) only, factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Default.Lib w/o Associate Nuclide contributions.
IRESRAD, version 6.5 Ta Limit = 30 days 11/28/2011 10:28 Page 3
Summary : HB soil DCGLCNi-59 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NI59 DCGL\\HB SOIL DCGLN159.RAD Site-Specific Parameter Summary 0
3 User ffUsed by RESRAD Me Input Default.(if diferent from.user input)
Parameter Name aAAAI A s.s.sAAAAAaAAAAaaAAAAaaAAAASaASAASaaASaSAAAAAAAAAAAA 5 3AAAAAAAAA..5 R011 Area of Contaminated zone (m**2)
R011 Thickness of contaminated zone (m)
RO1l Fraction of contamination that is submerged R011 Length parallel to aquifer flow (m)
R011 Basic radiation dose limit (mrem/yr)
RO11 Time since placement of material (yr)
RO11 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
RO11 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
ROll Times for calculations (yr)
R011 Times for calculations (yr)
RO11 Times for calculations (yr)
R012 Initial principal radionuclide (pCi/g):
Ni-59 R012 Concentration in groundwater (pCi/L):
Ni-59 R013 Cover depth (m)
R013 Density of cover material (g/cm**3)
R013 Cover depth erosion rate (m/yr)
R013 Density of contaminated zone (g/cm**3)
R013 Contaminated zone erosion rate (m/yr)
R013 Contaminated zone total porosity R013 Contaminated zone field capacity R013 Contaminated zone hydraulic conductivity (m/yr)
R013 3 Contaminated zone b parameter R013 Average annual wind speed (m/sec)
R013 Humidity in air (g/m**3)
R013 Evapotranspiration coefficient R013 Precipitation (m/yr)
R013 Irrigation (m/yr)
R013 I Irrigation mode R013 Runoff coefficient R013 Watershed area for nearby stream or pond (m**2)
R013 Accuracy for water/soil computations R014 Density of saturated zone (g/cm**3)
R014 Saturated zone total porosity R014 Saturated zone effective porosity R014 Saturated zone field capacity R014 Saturated zone hydraulic conductivity (m/yr) t DART L ETT, 3b3.000E+04 I 2.670E+00 O.OOOE+O0 1.950E+02 3 2.500E+01 O.000E+O0 1.000E+00 3.000E+00 3 1.OOOE+01 3.000E+01 1.000E+02 3.OOOE+02 1.000E+03 not used not used 1.000E+00 not used O.000E+00 not used not used 3 1.564E+00 2.200E-03 4.100E-01 9,500E-02 3,900E+00 5.600E+00 3.040E+00 not used 6.250E-01 9.100E-01 5.600E-01 overhead 3 5.000E-O 3 2.520E+07 1.OOOE-03 1.510E+00 4.300E-01 3.420E-01 8.800E-02 2.880E+01 1.000E+04 AREA 2.000E+00 THICKO 0.000E+00 SUBMFRACT 1.000E+02 LCZPAQ 3.000+E+1 BRDL 0.000E+00 TI 1.000E+O0 T( 2) 3.000E+00 T(
3) 1.00E+01 T( 4) 3.OOOE+01 T(
5) 1.000E+02 T(
6) 3.000E+02 T(
7) 1.000E+03 T(
8) 0.0OOE+O0 T(
9) 0.000E+00 T(1O)
O.OOOE+00 S1(1) 0.OOOE+00 W1(1)
O.000E+00 COVERO 1.500E+00 DENSCV 1.000E-03 VCV 1.SO0E+O0 DENSCZ 1.000E-03 vCz 4.OOOE-01 TPCZ 2.OOOE-01 FCCZ 1.OOOE+O1 HCCZ 5.300E+00 3--
BCZ 2.00E+O0 WIND 8.OOOE+00 3--
HUMID 5.000E-01 EVAPTR 1.000E+00 PRECIP 2.000E-01 RI overhead IDITCH 2.0008-01 RUNOFF 1.000E+06 WAREA 1.000E-03 3--
EPS 1.500E+00 DENSAQ 4.OOOE-O1 TPSZ 2.OOOE-OI EPSZ 2.000E-01 FCSZ 1.000E+02 HCSZ AAA Page 91
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R014 3 Saturated zone hydraulic gradient 2.OOOE-03 2.000E-02 R014 3 Saturated zone b parameter 7.100E+00 5.300E+00 R014 water table drop rate (m/yr) 1.O00E-03 3 1.000E-03 R014 well pump intake depth (m below water table) 1.000E+01 1.000E+O1 R014 ' Model: Nondispersion (ND) or MaSs-Balance (MR)
ND ND R014 3 Well pumping rate (m**3/yr) 1.573E+03 2.500E+02.
1RESRAD, Version 6.5 T' Limit = 30 days 11/28/2011 10:28 Page 4
Summary : He soil DCGLNi-59 File
- C:\\RESRADOFAMILY\\RESRAD\\6.5\\USERFILES\\NI59 DCGL\\HB SOIL DCGL._NI59.RAD Site-Specific Parameter Summary (continued) 0 User 3
menu Parameter I
nu eal i
BSZ VWT SDWI BWT MODEL 3 UW used by RESRAD Parameter different rom user input) 3 Name R015 3 Number of unsaturated zone strata 1
1 NS R015 3 Unsat. zone 1, thickness (m)
I 4.040E+00 3 4.000E+00 3 H(M)
R015 I Unsat. zone 1, soil density (g/cm**3) 1.564E+00 1.500E+00 DENSUZ(1)
RO15 Unsat. zone 1, total porosity 4.100E-01 4.0OOE-01 TPUZC1)
R015 Unsat. zone 1, effective porosity 3 3.150E-01 2.000E-01 EPUZ(1)
R015 Unsat. zone 1, field capacity 9.500E-02 2.000E-01 I FCUZ(1)
RO15 Unsat. zone 1, soil-specific b parameter 5.600E+00 3 5.300E+00 BUZ(1)
R015 Unsat. zone 1, hydraulic conductivity (m/yr)
I 3.900E+00 1.OOOE+01 HCUZ(1)
R016 Distribution coefficients for Ni-59 R016 3 Contaminated zone (cm**3/g) 4.240E+02 1.OOOE+03 3 DCNUCC( 1)
R016 unsaturated zone 1 (cm**3/g) 4.240E+02 1.OOOE+03 DCNUCU( 1,1)
R016 '
Saturated zone (cm**3/g) 4.240E+02 I 1.000E+03
' DCNUCS( 1)
R016 3 Leach rate (/yr) 0.OOOE+00 O.00OE+00 3 2.149E-04 I ALEACH( 1)
R016 3 Solubility constant O.OOOE+00 O.OOOE+00 I not used SOLUBK( 1)
R017 Inhalation rate (m**3/yr) 8.400E+03 ' 8.400E+03 INHALR R017 3 Mass loading for inhalation (g/m**3) 1.OOOE-04 I 1.000E-04 3 MLINH R017 3 Exposure duration 3.OOOE+01 3.000E+01 3 ED RO17 3 Shielding factor, inhalation 5.500E-01 4.000E-01 SHF3 ROl I7 Shielding factor, external gamma I 2.725E-01 3 7.DOOE-01 SHFI R017 3 Fraction of time spent indoors 6.571E-01 I 5.000E-01 3 FIND R017 3 Fraction of time spent outdoors (on site) 1.181E-01 I 2.500E-01 FOTD R017 3 Shape factor flag, external gamma 1.OOOE+O0 1.OOOE+00
>0 shows circular AREA.
FS RO17 Radii of shape factor array used if FS =-1):
R017 outer annular radius (m),
ring 1:
not used 5.OOOE+01 RAD.SHAPE(
1)
R017 3 outer annular radius (m),
ring 2:
not used 3 7.071E+01 RAD.SHAPE(
2)
R017 outer annular radius (m),
ring 3:
not used O.00OE+0O RADSHAPE(
3)
R017 Outer annular radius (m),
ring 4:
not used 0.OOOE+00 RADSHAPE(
4)
R017 outer annular radius (m),
ring 5:
3 not used 0.000E+00 RADSHAPE(
5)
R017 '
outer annular radius (m),
ring 6:
' not used 3 0.OOOE+00 RADSHAPE(
6)
RO17 outer annular radius (m),
ring 7:
3 not used 3 0.OO0E+0O 3 RAD.SHAPE(
7)
R017 Outer annular radius (m),
ring 8:
not used O.0E+00 3 3 RADSHAPE(
8)
R017 Outer annular radius (m),
ring 9:
not used 3 0.000E+00
' RADSHAPE( 9)
R017 I Outer annular radius (m), ring 10:
1 not used O.OOOE+00 PADSHAPE(1O)
R017 Outer annular radius (m),
ring 11:
not used 0.OOOE+00 RADSHAPE(11)
R017 Outer annular radius (m),
ring 12:
not used 0.00OE+00 3 3 RADSHAPE(12)
IRESRAD, version 6.5 To Limit 30 days 11/28/2011 10:28 Page Summary : H soil DCGL_Ni-59 File
- C:\\RESRAD-FAMILY\\RESRAD\\6.5\\USERFILES\\NI59 DCGL\\HB SOIL DCGLNI59.RAD Site-Specific Parameter Summary (continued) 0 3
User 3
ffused by RESRAD P
Farameter menu 3 Parameter Input Default
- (if different from user input)'3 Name R017 ' Fractions of annular areas within AREA:
R017l Ring 1
' not used
' 1.OOOE+00 FRACA( 1)
R017 '
Ring 2
not used I 2.732E-01 FRACA( 2)
R017 I Ring 3
not used 3 0.OOOE+0O I
' FRACA(
3)
R017o Ring 4
3 not used 0.O0OOE+00 3
3 FRACA( 4)
R017 I Ring 5
not used 0.O00E+0O FRACA( 5)
R017 I Ring 6
not used
' 0.OOOE+00 I
' FRACA( 6)
RO17 3 Ring 7 not used 3 0.0O0E+0O FPRACA( 71)
R017 I Ring 8
3 not used 3 O.OOOE+00 I FRACA(
8)
R017 I Ring 9
' not used
' 0.OOOE+00 I FRACA(
9)
RO17 3 Ring 10 3 not used O.OOOE+00 FRACA(10)
R017 I Ring 11 not used
' 0.000E+00 FRACA(li)
Roll 3 Ring 12 3 not used 3 0.000E+00 I FRACA(12)
R018 ' Fruits, vegetables and grain consumption (kg/yr)
' 1.120E+02 ' 1.600E+02 DIET(i)
ROI8 3 Leafy vegetable consumption (kg/yr) 3 2.140E+01 3 1.400E+01 I 3 DIET(2)
R018 Milk consumption (L/yr)
I 2.330E+02 3 9.200E+01 DIET(3)
R018 3 Meat and poultry consumption (kg/yr)
I 6.510E+01 3 6.300E+01 3 DIET(4)
R018 3 Fish consumption (kg/yr) 2.060E+01 5.400E+00 DIET(S)
R018 I other seafood consumption (kg/yr) 9.OOOE-01 9.OOOE-01 DIET(6)
R018 3 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 SOIL R018 3 Drinking water intake (L/yr) 4.785E+02 5.100E+02 W---
WI R018 3 Contamination fraction of drinking water 1.OOOE+00 1.0OOE+OO FDW R018 ' Contamination fraction of household water not used 1.OOOE+00 FHHW R018
' Contamination fraction of livestock water 1.00OE+0O 1.000E+00 FLW R018 ' Contamination fraction of irrigation water 1.000E+00 1.OOOE+00 FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.OOOE-01 FR9 R018 Contamination fraction of plant food 1.000E+00 '-1 FPLANT R018 Contamination fraction of meat 1.OOOE+00 '-1 FMEAT R018 3 Contamination fraction of milk 1.OOOE+00 '-1 FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 I 6.800E+01 LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 LFI6 R019 Livestock water intake for meat (L/day) 3 5.060E+01 3 5.OOOE+01 LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 I 1.600E+02 LWI6 R019 3 Livestock soil intake (kg/day) 5.OOOE-01 5.000E-01 'LSI R019 Mass loading for foliar deposition (g/m**3) 3 4.OOOE-04 1.OOOE-04 3 MLFD R019 Depth of soil mixing layer (m) 2.300E-01 I 1.500E-01 DM ROl9 ' Depth of roots (m) 1.220E+00 9.000E-01 DROOT R019 Drinking water fraction from ground water I 1.0OOE+00 I 1,OOOE+00 I FGWDW R019 3H ousehold water fraction from ground water 3 not used I 1O00OE+00 FGWHM R019 Livestock water fraction from ground water 1.OOOE+00 1.OOOE+00 '--
FGWLW R019 3 Irrigation fraction from ground water 1.00OE+00 3 1.000E+00 3 FGWR R19B wet weight crop yield for Non-Leafy (kg/m 55 2) 1.750E+00 7.000E-01 YV(1)
R19B wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 YV(2)
R19B wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E400 YV(3)
R198 Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 TE(l)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.OOOE-02 TE(3)
BARTLETPage 92
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 1RESRAD, Version 6.5 T< Limit = 30 days 11/28/2011 10:28 Page 6
Summary HB soil DCGLNi-9 File C:\\RESRADFAMILY\\RESBAD\\6.5\\USERFILES\\NI59 DCGL\\HB SOIL DCGL_N159.RAD site-Specific Parameter Summary (continued) 0 3
P User 3
ffUsed by RESRAD Parameter menu 3 Par ter..
.Input Default 3.(if diferent from user input)
Name R19B Translocation Factor for Non-Leafy 1,OOOE-01 1.OOQE-01 TIV(1)
R19B Translocation Factor for Leafy 1.OOOE+00 1.OOOE+00 TIV(2)
R19B Translocation Factor for Fodder I.OOOE+00 1.000E+00 TIV(3)
RI9B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 3--
RDRY(i)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 RDRY(2)
RI9B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 3--
RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.5005-O03 2.500E-01 RWET(3)
R19B Weathering Removal Constant for Vegetation 3.300E+01 2.OOOE+01 WLAM C14 C-12 concentration in water (g/cm**3) not used 2.OOOE-05 C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 C12CZ C14 Fraction of vegetation carbon from soil not used 2.OOOE-02 CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.OOOE-01 DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 EVSN C14 C-12 evasion flux rate from soil (1/sec) not used I1.O0E-1O REVSN C14 Fraction of grain in beef cattle feed not used 8.00OE-01 AVFG4 C14 Fraction of grain in milk cow feed not used 2.OOOE-01I AVFG5 S'rOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 STOR.T(1)
STOR Leafy vegetables 1.OOOE+00 1.OOOE+00 STORT(2)
STOR Milk 1.000E+00 1.0OOE+00 STORT(3)
STOR Meat and poultry 2.OOOE+01 2.OOOE+01 STORT(4)
STOR Fish 7.000E+00 7.OOOE+00 STORT(S)
STOR Crustacea and mollusks 7.OOOE+00 7.O00E+00 STORT(6)
STOR Well water 1.OO0E+00 1.OOOE+0O STORT(7)
STOR Surface water 1.OOOE+00 1.000E+00 STOeT(8)
STOR Livestock fodder 4.500E+01 4.500E+01 STORT(9)
R021 Thickness of building foundation (m) not used 1.500E-01 FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 DENSFL R021 Total porosity of the cover material not used 4.OOOE-01 TPCV R021 Total porosity of the building foundation not used 1.OOOE-01 TPFL R021 volumetric water content of the cover material not used 5.OOOE-02 PH2OCV R021 volumetric water content of the foundation not used 3.000E-02 PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.OOOE-06 DIFCV R021 in foundation material not used 3.OOOE-07 DIFFL R021 in contaminated zone soil not used 2.000E-06 DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.OOOE+00 HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 REXG R021 Height of the building (room)
(m) not used 2.500E+00 HRM R021 Building interior area factor not used 0.000E+00 FAI R021 Building depth below ground surface (m) not used 3 -1.000E+00 DMFL R021 Emanating power of Rn-222 gas not used 3 2.500E-01 EMANA(1)
R021 Emanating power of Rn-220 gas not used 3 1.500E-01 EMANA(2)
TITL Number of graphical time points 32 NPTS IRESRAD, Version 6.5 T,< Limit = 30 days 11/28/2011 10:28 Page 7
Summary : HB soil DCGLNi-59 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NI59 DCGL\\HB SOIL DCGLNI59.RAD site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu 3 e
Input 3 Default (If different from user input) 3 Name TITL 3 maximum number of integration points for dose 3
17 LYMAX TITL 3 Maximum number of integration points for risk 1 7 3
KYMAX Summary of Pathway Selections Pathway.
User Selection
-- external gamma active 2
inhalation (w/o radon)'
active 3--
plant ingestion active 4
meat ingestion active 5
milk ingestion active 6
aquatic foods active 7
drinking water active 8
soil ingestion active 9 --
radon suppressed Find peak pathway doses active IRESRAD, Version 6.5 T<, Limit = 30 days 11/28/2011 10:28 Page 8
Summary : KB soil DCGLNi-59 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NI59 DCGL\\HB SOIL DCGLNI59.RAD Contaminated zone Dimensions Initial..Soil Concentrations,..p.i/g Area:
30000.00 square meters Ni-59 1.OOOE+00 Thickness:
2.67 meters Cover Depth:
0.00 meters 1RESRAD, Version 6.5 T-Limit = 30 days 11/28/2011 10:28 Page 1
Probabilistic results summary : HB soil DCGL.Ni-59 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NI59 DCGL\\HB SOIL DCGL-N159.RAD Table of Contents Part VI: Uncertainty Analysis ORESRAD Uncertainty Analysis Results Probabilistic Input..................................
2 Total Dose...
3 Total Risk............................................
4 Dose vs Pathway:
Ground External 5
CBARTLETT Page 93
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 Dose vs Pathway:
Inhalation (w/o Radon) 6 Dose vs Pathway:
Radon (Water Ind.).................
7 Dose vs Pathway:
Plant (Water Ind.)................
8 Dose vs Pathway:
Meat (Water Ind.)................
9 Dose vs Pathway:
Milk (Water Ind.)
10 Dose vs Pathway:
Soil Ingestion.....................
11 Dose vs Pathway:
Water Ingestion....................
12 Dose vs Pathway:
Fish Ingestion.....................
13 Dose vs Pathway:
Radon (Water Dep.)................
14 Dose vs Pathway:
Plant (Water Dep.)................
15 Dose Vs Pathway:
Meat (Water Dep.)................
16 Dose vs Pathway:
Milk (Water Dep.)................
17 Cumulative Probability Sumnmary.......................
18 Summary of dose at graphical times, reptition 1.....
19 Peak of the mean dose at graphical times.............
20 Correlation and Regression coefficients (if any).....
21 1RESRAD, Version 6.5 Tc Limit = 30 days 11/28/2011 10:28 Page 2
Probabilistic results summnary : HB soil DCGL..Ni-59 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NI59 DCGL\\HB SOIL DCGLNI59.RAD Probabilistic Input ONumber of sample Runs: 2000 Number Name Distribution Parameters 1
DENSCZ BOUNDED NORMAL 1.5635
.2385
.827 2.3 2
TPCZ BOUNDED NORMAL
.41
.09
.1319
.6881 3
HCCZ BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 4
BCZ BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 5
EVAPTR UNIFORM
.5
.75 6
RI UNIFORM
.36
.76 7
DENSAQ BOUNDED NORMAL 1.5105
.1855
.937 2.084 8
TPSZ BOUNDED NORMAL
.43
.0699
.214
.646 9
EPSZ BOUNDED NORMAL
.342
.0705
.124
.56 10 HCSZ BOUNDED LOGNORMAL-N.362 1.59
.0106 195 11 BSZ BOUNDED LOGNORMAL-N 1.96
.265 3.02 15.5 12 DWIBWT TRIANGULAR 6
10 30 13 Uw UNIFORM 1173 1973 14 H(1)
UNIFORM 0
8.08 15 DENSUZ(1)
BOUNDED NORMAL 1.5635
.2385
.827 2.3 16 TPUZ(1)
BOUNDED NORMAL
.41
.09
.1319
.6881 17 EPUZ(1)
BOUNDED NORMAL
.315
.0905
.0349
.594 18 HCUZ(1)
BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 19 BUZ(1)
BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 20 MLINH CONTINUOUS LINEAR 8
0 0
.000008
.0151
.000016
.1365
.00003
.8119
.00004
.9495
.00006
.9937
.000076
.9983
.0001 1
21 SHF3 UNIFORM
.15
.95 22 SHF1 BOUNDED LOGNORMAL-N -1.3
.59
.044 1
23 DM TRIANGULAR 0
.15
.6 24 Yv(1),
TRUNCATED LOGNORMAL-N.56
.48
.001
.999 25 WLAM TRIANGULAR 5.1 18 84 26 RWET(2)
TRIANGULAR
.06
.67
.95 27 DCACTC(1)
TRUNCATED LOGNORMAL-N 6.05 1.46
.001
.999 28 DCACTU1(1)
TRUNCATED LOGNORMAL-N 6.05 1.46
.001
.999 29 DCACTS(1)
TRUNCATED LOGNORMAL-N 6.05 1.46
.001
.999 30 BRTF(28,2)
TRUNCATED LOGNORMAL-N -5.3
.9
.001
.999 31 BBIO(28 1)
LOGNORMAL-N 4.6 1.1 IRESRAD, version 6.5 Tý Limit = 30 days 11/28/2011 10:28 Page 20 Probabilistic results summary : HB soil DCGLNi-59 File : C:\\RESRAD-pAMILY\\RESRAD\\6.5\\USERFILES\\NI59 DCGL\\HB SOIL DCGLNI59.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1
0.OO0E+00 1.269E-02 tBA T LETT Page 94
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Ni-63 Results:
IRESRAD, Version 6.5 Tcc Limit = 30 days 11/28/2011 10:32 Page 1
Summary HB soil DCGLNi-63 File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NI63 DCGL\\HB SOIL DCGLN163.RAD Table of Contents AAAAAAAAAAAAAAAAA Part I: Mixture Sums and Single Radionuclide Guidelines fltlfittffttttttfttttffftf~titttttttttffftftfiiftffit~t Dose Conversion Factor (and Related) Parameter Summary...
2 Site-Specific Parameter Summary..........................
3 Summary of Pathway Selections..............................
7 Contaminated Zone and Total Dose Summary 8
Total Dose Components Time = 0.000E+00....................................
9 Time = 1.OOOE+00....................................
10 Time = 3.OOOE+00.....................................
11 Time = 1.OOOE+01.....................................
12 Time = 3.000E+01.....................................
13 Time = 1.000E+02..
14 Time = 3.OOOE+02..
15 Time = 1.000E+03..
16 Dose/Source Ratios Summed Over All Pathways...............
17 Single Radionuclide Soil Guidelines.......................
17 Dose Per Nuclide Summed Over All Pathways.................
18 Soil Concentration Per Nuclide.....................
18 1RESRAD, version 6.5 T. Limit = 30 days ii/28/2011 10:32 Page 2
Summary : HB soil DCGLNi-63 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\Ni63 DCGL\\HB SOIL DCGLN163.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: HB DCGLs Plus FGR 12 & FGR 11 0
3 3 Current 3
Base I Parameter Menu P
Parameter value#
3 Case*
I Name A-1 DCF's for external ground radiation, (mrem/yr)/(pci/g)
A-1 Ni-63 (Source: FGR 12) 0.000E+00 0.000E+00 DCFI(
1)
B-i Dose conversion factors for inhalation, mrem/pCi:
B-1 Ni-63 6.290E-06 I 6.290E-06 DCF2(
1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-i Ni-63 5.770E-07 5.770E-07 DCF3(
1)
D-34 Food transfer factors:
D-34 Ni-63
, plant/soil concentration ratio, dimensionless 9.120E-02 5.OOOE-02 RTF(
1,1)
D-34 Ni-63 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.OOOE-03 5.O0E-O3 RTF(
1,2)
D-34 Ni-63 milk/livestock-intake ratio, (pCi/L) /(pCi/d) 3.210E-02 2.OOOE-02 RTF(
1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Ni-63
, fish 1.000E+02 1.000E402 BIOFAC(
1,1)
D-5 Ni-63 crustacea and mollusks 1.OOOE+02 I.OOOE+02 BIOFAC(
1 2)
- For DCFI(xxx) only, factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Default.Lib w/o Associate Nuclide contributions.
iRESRAD, Version 6.5 T. Limit = 30 days 11/28/2011 10:32 Page 3
Summary : HB soil DCGLNi-63 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\Ni63 DCGL\\HB SOIL DCGLN163.RAD site-Specific Parameter Summary 0
User 3
ffused by RESRAD Parameter menu 3
Y Pa r
Input 3 Default (if dif erent from user input) 3 Name
&AAA ROli Area of contaminated zone (m**2) 3.OOOE+04 I.OOOE+O4 AREA ROll Thickness of contaminated zone (m) 2.670E+00 2.OOOE+00 THICKO ROli Fraction of contamination that is submerged O.OOOE+OO I.000E+00 SUBMFRACT R011 Length parallel to aquifer flow (m) 1.950E+02 1.000E+02 LCZPAQ RO11 Basic radiation dose limit (mrem/yr) 2.500E+013 3.000E+01 BRDL ROi3 Time since placement of material (yr)
O.000E+00 O.000E+OO TI RO11 Times for calculations (yr) 1.00E+OO0 1.OOOE+0O T( 2)
R011 Times for calculations Cyr) 3.OOOE+00 3.000E+00 T( 3)
ROll Times for calculations (yr) 1.OOOE+
3 1.O000E+01 T( 4)
ROll Times for calculations (yr) 3.00OE+OI 3.OOOE+01 T(
5)
R011 Times for calculations (yr) 1.0OOE+02 I1.OOOE+02 T( 6)
ROll Times for calculations (yr) 3.OOOE+02 3.OOOE+02 T(
7)
R011 Times for calculations (yr) 1.0OOE+03 I.O00E+03 T( 8)
R011 Times for calculations (yr) not used O.OOOE+00 T(
9)
ROil Times for calculations (yr) not used O.O00E+00 T(1O)
R012 Initial principal radionuclide (pCi/g):
Ni-63 1.00OE+O0 O.000E+0O
$1(1)
R012 Concentration in groundwater (pCi/L):
1)
R013 Cover depth (m)
O.00E+O0 O.008E+00 COVERO ROl3 Density of cover material (g/cm**3) not used 1.500E+00 DENSCV R013 cover depth erosion rate (m/yr) not used I1.O00E-03 VCV ROl3 Density of contaminated zone (g/cm3)3 1.564E+00 1.500E+00 3 DENSCZ R013 Contaminated zone erosion rate (m/yr) 2.200E-03 1.O00E-03 VCZ R013 contaminated zone total porosity 4.100E-01 4.000E-01 3 TPCZ RO13 Contaminated zone field capacity 9.500E-02 I 2.000E-01 FCCZ RO13 Contaminated zone hydraulic conductivity (m/yr) 3.900E+00 1.O00E+01 HCCZ RO13 Contaminated zone b parameter 5.600E+00 5.300E+00 BCZ RO13 Average annual wind speed (m/sec) 3.040E+00 2.00OE+O0 WIND ROi3 Humidity in air (g/m**3) not used 8.0008E+0 HUMID ROi3 Evapotranspiration coefficient 6.250E-01 5.000E-Oi EVAPTR R013 Precipitation (m/yr) 9.100E-01 1.O00E+00 PRECIP R013 Irrigation (m/yr) 5.600E-01I 2.000E-01 RI R013 Irrigation node overhead overhead IDITCH R013 Runoff coefficient 5.000E-01 2.000E-01 RUNOFF R013 Watershed area for nearby stream or pond (m**2) 2.520E+07 1.O00E+06 WAREA R013 3 Accuracy for water/soil computations 1.000E-03 1.000E-03 EPS R014 Density of saturated zone (g/cm**3) 1.510E+00 1.500E+O0 DENSAQ R014 Saturated zone total porosity 4.300E-01 4.000E-01 I TPSZ R014 I Saturated zone effective porosity 3.420E-01 2.000E-01 EPSZ R014 3 Saturated zone field capacity 8.800E-02 2.000E-01 I 3 FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 2.880E+01 I1.O00E+02 HCSZ BARTLETT Page 95
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R014 Saturated zone hydraulic gradient 2.OOOE-03 2.OOOE-02 R014 Saturated zone b parameter 7.100E+00 5.300E+00 R014 water table drop rate (m/yr) 1.000E-03 1.OOOE-03 R014 Well pump intake depth (m below water table) 1.000E+O1 1.OOOE+01 R014 3 Model: Nondispersion (ND) or Mass-Balance (MB) 3 NO NO R014 3 well pumping rate (m**3/yr) 1.573E+03 2.500E+02 1RESRAD, version 6.5 To Limit. 30 days 11/28/2011 10:32 Page 4
Summary : HB soil DCGLNi-63 File
- C:\\RESBADFAMILY\\RESRAD\\6.5\\USERFILES\\NI63 DCGL\\HB SOIL DCGLN163.RAD site-specific Parameter Summary (conti 0
3 3
User Menu 3 Parameter 3.input 3.. efault R015 Number-of unsaturated zone strata 1
3 1 RO15 Unsat. zone 1, thickness (m) 3 4.040E+00 3 4.OOOE+O0 RO15 Unsat. zone 1, soil density (g/cm**3) 1.564E+00 1.50OE+O0 R015 Unsat. zone 1, total porosity 3 4.1OOE-01 I 4.OOOE-O1 R015 Unsat. zone 1, effective porosity 3.150E-01 I 2.OOOE-01 R015 Unsat. zone 1, field capacity 9.SOOE-02 3 2.OOOE-01 R015 unsat. zone 1, soil-specific b parameter 35.600E+00 5.300E+00 ROt5 Unsat. zone 1, hydraulic conductivity (m/yr) 3.900E+00 t
I.OOOE+01 R016 Distribution coefficients for Ni-63 3
R016 contaminated zone (cm**3/g) 4.240E+02 3 1.OOOE+03 R016 unsaturated zone 1 (cm**3/g) 4.240E+02 t
1.000E+03 RO16 Saturated zone (cm**3/g) 4.240E+02 3 1.OOOE+03 RO16 Leach rate (/yr)
O.OOOE+O0 3O.OOOE+0O R016 solubility constant O.OOOE+O0 O.O0OE+O0 R017 Inhalation rate (m**3/yr) 8.400E+03 3 8.400E+03 R017 Mass loading for inhalation (g/m**3) 1.OOOE-04 3 1.OOOE-04 R017 Exposure duration 3.OO0E+01 3.O0OE+O1 R017 Shielding factor, inhalation 5.500E-01 4.OOOE-O1 R017 Shielding factor, external gamma 2.725E-01 7.OOOE-01 R017 Fraction of time spent indoors 6.571E-ol 3 5.OOOE-01 ROl7 Fraction of time spent outdoors (on site) 1.181E-01l 2.500E-01 RO17 Shape factor flag, external gamma 1.O0E+00 3 1.OOOE+O0 R017 Radii of shape factor array (used if FS
-1):
R017 Outer annular radius (m),
ring 1:
not used 5.OOOE00EO1 R017 outer annular radius (m),
ring 2:
not used 7.071E+01 R017 outer annular radius (m),
ring 3:
not used 3 O.OooE+00 RO17 outer annular radius (m),
ring 4:
not used 9 O.OoOE+O0 R017 outer annular radius (m),
ring 5:
not used O.OOOE+O0 ROll outer annular radius (m),
ring 6:
not used O.OOoE+0O R017 outer annular radius (m),
ring 7:
not used O.OOOE+0O R017 outer annular radius (m),
ring 8:
not used O.OOOE+OO R017 outer annular radius (m),
ring 9:
not used 0.OOE+OO R017 outer annular radius (m),
ring 10:
not used 0.OOOE+0O R017 outer annular radius (m),
ring 11:
not used O.000E+0O R017 outer annular radius (m),
ring 12:
not used O.OOOE+O0 iRESRAD, Version 6.5 T-Limit = 30 days 11/28/2011 10:32 Page 5
Summary : HB soil DCGL_Ni-63 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NI63 DCGL\\HB SOIL DCGL-N163.RAD inued) used by RESRAD (If different from user input) 2.149E-04 not used
>0 shows circular AREA.
3_
- a 3 HGWT 3 BSZ VWT DWIBWT MODEL UW Parameter Name NS 3 H(1) 3 DENSUZ(1) 3 TPUZ(1)
' EPUZ(1) 3 FCUZ(1) 3 BUZ(1)
HCUZ(1)
DCNUCCC 1)
DCNUCU( 1,I) 3 DCNUCS( 1)
ALEACHM 1)
SOLUBK( 1)
INHALR MLINH ED 3 SHF3 SHF1 FIND 3 FOTD 3 FS BADSHAPE(
1) 3 RADSHAPE(
2) 3 BAD-SHAPE(
3) 3OP.AD_SHAPE(
4)
PADSHAPE( 5)
PADSHAPE( 6)
RADSHAPE(
7) 3 RAD_SHAPE(
8)
RAD.SHAPEC 9)
RADSHAPE (10)
RADSHAPE (11)
RAD.SHAPE(12)
Parameter Name FRACA( 1)
FRACA( 2)
FRACA( 3)
FRACAC 4) 3 FRACA( 5) 3 FRACA( 6) 3 FPACA( 7)
' FRACA( 8) 3 FRACA( 9) 3 FRACA(IO) 3 FRACA(11)
FRACA(12)
DIET(1)
DIET(2)
DIET(3)
' DIET(4)
DIET(5)
DIET(6)
SOIL 3 DWI FDW 3FHHW
' FLW 3 FIRW FR9 3 FPLANT FMEAT FMILK LFI5 LFI6 LWI5 3Lw16 3 LSI MLFD 3 DM 3 DROOT FGWDW FGWHH FGWLW FGWIR YV(1)
YV(2)
Yv(3) 3 TE(1)
TE(2)
TE(3) 0 Menu 3Parameter R017 Fractions of annular areas within ROl7 Ring 1
ROl7 Ring 2
R017 Ring 3
ROl7 Ring 4
ROl7 Ring 5
R017 Ring 6
RO17 3 Ring 7
RO17 Ring 8
R017 Ring 9
R017 Ring 10 R017 Ring 11 ROl7 Ring 12 R018 Fruits, vegetables and grain consul R018 Leafy vegetable consumption (kg/yr R018 Milk consumption (L/yr)
RO18 Meat and poultry consumption (kg/y R018 Fish consumption (kg/yr)
R018 other seafood consumption (kg/yr)
R018 Soil ingestion rate (g/yr)
R018 Drinking water intake (L/yr)
R018 contamination fraction of drinking R018 contamination fraction of househol R018 contamination fraction of livestoc R018 contamination fraction of irrigati RO18 contamination fraction of aquatic R018 Contamination fraction of plant foi R018 Contamination fraction of meat R018 Contamination fraction of milk R019 Livestock fodder intake for meat C R019 Livestock fodder intake for milk C ROI9 Livestock water intake for meat (L R019 Livestock water intake for milk (L R019 Livestock soil intake (kg/day)
R019 Mass loading for foliar deposition R019 Depth of soil mixing layer (m)
R019 Depth of roots Cm)
R019 Drinkink water fraction from groun R019 Household water fraction from grou R019 Livestock water fraction from grou R019 Irrigation fraction from ground wa R19B wet weight crop yield for Non-Leaf R19B wet weight crop yield for Leafy R19B wet weight crop yield for Fodder R19B Growing Season for Non-Leafy (yea R19B Growing season for Leafy (yea RI91 Growing season for Fodder (yea 10 BA RT L ETT site-specific Parameter Summary (continued)
User e
u used by RESRAD 3.input o..efault 3 (if different from user input)
AREA:
not used 1.OO0E+00 not used 3 2.732E-01 not used 3 O.OOOE+O0 not used 3 O.OOOE+0O not used
' 0.O0OE+00 3 not used 9 O.OOOE+00 not used 3 O.OOOE+OO not used 0.0OOE+O0 3 not used O.OOOE+00 3 not used O.OOOE+00 not used O.OOOE+00 3 not used 0.O00E+00 xption (kg/yr) 1.120E+02 1.600E+02 3 2.140E+01 3 1.400E+01 2.330E+02 I 9.200E+01 r) 6.510E+01 6.300E+01 l
2.060E+01 5.400E+00 9.OOOE-O1 9.OOOE-O1 1.826E+01 3.650E+01 4.785E+02 I 5.100E+02 water 1.OOOE+00 3 1.000E+00 d water not used I.OOOE+O0 k water 1.OO0E+0O 1.OOOE+0O on water 1.OOOE+OO 1.OOOE+00 food 1.OOOE+00 5.000E-0l 3 od 1.OOOE+00 '-1 l.OOOE+OO '-I 1.O00OE+0O 3-i kg/day) 2.710E+01 I 6.800E+01 kg/day) 6.320E+01 ' 5.500E+O1
/day) 5.060E+01 3 5.OOOE+OO
/day) 6.OOOE+01 ' 1.600E+02 5.OOOE-OlI 5.OO0E-Ol (g/m**3) 4.OOOE-04 3 1.00OE-04 2.300E-01 3 1.SOOE-01 1.220E+00 3 9.00OE-01 d water I.OOOE+O0
' 1.0OOE+O0 nd water not used 3 I.O0OE+O0 nd water 1.OOOE+OO ' 1.000E+00 3 ter I.O00E+0O 1.OOOE+O y (kg/m**2) 1.750E+00 7.000E-01 (kg/m**2) 2.889E+00 1.500E+00 (kg/m**2) 1.887E+00 1
1.100E+O0 rs) 2.460E-01 1.700E-Ol rs) 1.230E-01 2.500E-O1 rs) 8.200E-02 8.OOOE-02 Page 96
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 1RESRAD, version 6.5 To Limit = 30 days 11/28/2011 10:32 Page 6
Summary HB soil DCGLNi-63 File
- C:\\RESRADFAMILY\\RESBAD\\6.S\\USERFILES\\NI63 DCGL\\HB SOIL DCGLN163.RAD Site-Specific Parameter Summary (continued) 0 3
User ffUsed by RESRAD Parameter Menu Parameter 3.Input 3.Default
(*(if diferent from user input)
Name R19B R19B R19B R19B R19B R19B R19B R19B R19B C14 C14 C14 C14 C14 C14 C14 c14 c14 STOR STOR STOR STOR STOR STOR STOR STOR STOR STOR R021 R021 R021 R021 R021 R021 R02 1 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 Translocation Factor for Non-Leafy Translocation Factor for Leafy I
Translocation Factor for Fodder a
Dry Foliar Interception Fraction for Non-Leafy Dry Foliar Interception Fraction for Leafy Dry Foliar Interception Fraction for Fodder wet Foliar Interception Fraction for Non-Leafy wet Foliar Interception Fraction for Leafy 3 wet Foliar Interception Fraction for Fodder 3 weathering Removal Constant for vegetation C-12 concentration in water (g/cm**3)
C-12 concentration in contaminated soil (g/g)
Fraction of vegetation carbon from soil 3 Fraction of vegetation carbon from air C-14 evasion layer thickness in soil (m)
C-14 evasion flux rate from soil (1/sec) c-12 evasion flux rate from soil (1/sec)
Fraction of grain in beef cattle feed Fraction of grain in milk cow feed Storage times of contaminated foodstuffs (days):
Fruits, non-leafy vegetables, and grain Leafy vegetables Milk Meat and poultry Fish Crustacea and mollusks well water Surface water Livestock fodder T
Thickness of building foundation (i)
Bulk density of building foundation (g/cm**3)
T Total porosity of the cover material Total porosity of the building foundation volumetric water content of the cover material volumetric water content of the foundation Diffusion coefficient for radon gas (m/sec):
I in cover material in foundation material in contaminated zone soil Radon vertical dimension of mixing (m)
Average building air exchange rate (1/hr)
Height of the building (room)
(i)
Building interior area factor Building depth below ground surface (m)
Emanating power of Rn-222 gas Emanating power of Rn-220 gas I.OOOE-01 I.O00E-01 1.OOOE+00 1.000E+00 1.OOOE+O 1.0006+00 3.500E-01 2.500E-01 3.500E-01 2.500E-01 3.500E-01 2.500E-01 3.500E-01 2.500E-01 5.800E-01 2.500E-01 3.50OE-01 2.500E-01 3.300E+01 2.OO0E+O1 not used 2.000E-05 not used 3.000E-02 not used 2.OOOE-02 not used 9.800E-01 not used 3.OOOE-01 not used 7.OOOE-07 not used 1.OOOE-10 not used 8.000E-01 not used 2.000E-01 1.400E+01 1.400E+01 1.OOOE+00 1.OOOE+00 1.000E+00 1.000E+00 2.000E+01 2.OOOE+01 7.00OE+00 7.O00E+00 7.000E+O0 7.O00E+00 1.OOOE+00 1.OOOE+00 1.0OOE+00 1.0OOE+00 4.500E+01 4.500E+01 not used 1.500E-O1 not used 2.400E+00 not used 4.OOOE-01 not used 1.000E-01 not used 5.OOOE-02 not used 3.0OOE-02 not used 2.OOOE-06 not used 3.OOOE-07 not used 2.OOOE-06 not used 2.0OOE+00 not used 3O5.OE-01 not used 2.SOOE+00 not used 3O.000E+O0 not used
'-1.OOOE+00 not used I 2.S006-01 not used 3 1.500E-01
'TIV(i)
TIV(2)
'TIV(3) 3 RDRY(1) 3 RDRY(2) 3 RDRY(3) 3 RWET(1)
RWET(2)
RWET(3)
WLAM c12WTR 3 cl2cz 3 CSOIL 3 CAIR 3 DMC EVSN REVSN 3 AvFG4 3 AVFG5 STORj'(1)
STOFLT (2)
STORS(3)
STOLRT(4)
STORjT(5)
STOR-T(6) 3 STOFUT(7)
' STORr(8) 3 STOROr(9)
FLOORI DENSFL TPCV TPFL
'PI42OCV 3 PH2OFL DIFCV DIFFL DIFCZ HMIX 3 REXG HRM FAI DMFL 3 EMANA(1) 3 EMANA(2)
TITL Number of graphical time points 32 NPTS 1RESRAD, version 6.5 Ta' Limit = 30 days 11/28/2011 10:32 Page 7
Summary : HB soil DCGL-Ni-63 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\Ni63 DCGL\\HB SOIL DCGLN163.RAD Site-Specific Parameter Summary (continued) 0 user used by RESRAD Parameter Menu 3 Parameter input Default (if different from user input)
Name TITL 3 Maximum number of integration points for dose 17 LYMiAX TIML maximum number of integration points for risk k
.1..
KYMAX Summary of Pathway Selections Pathway User Select.i.on
-- external gamma 3
active 2
inhalation (w/o radon) 3 active 3 -- plant ingestion active 4-- meat ingestion active 5
milk ingestion active 6
aquatic foods active 7-- drinking water active 8
soil ingestion active 9
radon suppressed Find peak pathway doses I
active fffilfltfiltlf lilifffflillfffiff~tl/iilifliftfiffi IRESRAD, Version 6.5 Ta' Limit = 30 days 11/28/2011 10:32 Page 8
Summary : HB soil DCGL-Ni-63 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NI63 DCGL\\HB SOIL DCGL_N163.RAD Contaminated zone Dimensions Initial Soil Concentrations, p~i/g xxaxxxxxxxxxxxxxxxxxxs XWXAAAXXXXAAAAAAAXXXXXXAASAAAaAAAA Area:
30000.00 square meters Ni-63 1.OOOE+00 Thickness:
2.67 meters Cover Depth:
0.00 meters 1RESRAD, Version 6.5 Ta' Limit = 30 days 11/28/2011 10:32 Page 1
Probabilistic results summary : HB soil DCGL.Ni-63 File : C:\\RESRADFAMILY\\RESBAD\\6.S\\USERFILES\\NI63 DCGL\\HB SOIL DCGLN163.RAD Table of Contents Part vI: Uncertainty Analysis ORESRAD Uncertainty Analysis Results Probabilistic Input...................................
2 Total Dose...
3 Total Risk..
4 t
BARTLETT Page 97
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Dose vs Pathway:
Ground External...................
S Dose vs Pathway:
Inhalation (w/o Radon)............
6 Dose vs Pathway:
Radon (Water Ind.)
7 Dose vs Pathway:
Plant (Water Ind.)................
8 Dose vs Pathway:
Meat (Water Ind.)................
9 Dose vs Pathway:
Milk (water Ind.).................
10 Dose vs Pathway:
Soil Ingestion.....................
11 Dose vs Pathway:
water Ingestion....................
12 Dose vs Pathway:
Fish Ingestion.....................
13 Dose vs Pathway:
Radon (water Dep.)
14 Dose vs Pathway:
Plant (water Dep.)
15 Dose vs Pathway:
Meat (Water Dep.)
16 Dose vs Pathway:
Milk (water Dep.)
17 Cumulative Probability Summary.......................
18 Summary of dose at graphical times, reptition I...
19 Peak of the mean dose at graphical times.............
20 Correlation and Regression coefficients (if any).....
21 1RESRAD, Version 6.5 T<- Limit = 30 days 11/28/2011 10:32 Page 2
Probabilistic results summary : KB soil DCGLJNi-63 File : C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\NI63 DCGL\\HB SOIL DCGLN163.RAD Probabilistic Input ONumber of Sample Runs: 2000 Number 12 3
45 6
7 8
9 10 11 12 13 14 iS 16 17 18 19 20
.00003 21 22 23 24 25 26 27 28 29 30 31 tIffft Name Distribution parameters DENSCZ BOUNDED NORMAL 1.5635
.2385
.827 2.3 TPCZ BOUNDED NORMAL
.41
.09
.1319
.6881 HCCZ BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 BCZ BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 EVAPTR UNIFORM
.5
.75 RI UNIFORM
.36
.76 DENSAQ BOUNDED NORMAL 1.5105
.1855
.937 2.084 TPSZ BOUNDED NORMAL
.43
.0699
.214
.646 EPSZ BOUNDED NORMAL
.342
.0705
.124
.56 HCSZ BOUNDED LOGNORMAL-N.362 1.59
.0106 195 BSZ BOUNDED LOGNORMAL-N 1.96
.265 3.02 15.5 DWIBWT TRIANGULAR 6
10 30 UW UNIFORM 1173 1973 H(1)
UNIFORM 0
8.08 DENSUZ(1)
BOUNDED NORMAL 1.5635
.2385
.827 2.3 TPUZ(1)
BOUNDED NORMAL
.41
.09
.1319
.6881 EPUZ(1)
BOUNDED NORMAL
.315
.090S
.0349
.594 HCUZ(1)
BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 BUZ(1)
BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 MLINH CONTINUOUS LINEAR 8
0 0
.000008
.0151
.000016
.1365
.8119
.00004
.9495
.00006
.9937
.000076
.9983
.0001 1
SHF3
, UNIFORM
.15
.95 SHF1 BOUNDED LOGNORMAL-N -1.3
.59
.044 1
DM TRIANGULAR 0
.15
.6 Yv(1)
TRUNCATED LOGNORMAL-N.56
.48
.001
.999 WLAM TRIANGULAR 5.1 18 84 RWET(2)
TRIANGULAR
.06
.67
.95 DCACTC(1)
TRUNCATED LOGNORMAL 6.05 1.46
.001
.999 DCACTUC(1)
TRUNCATED LOGNORMAL-N 6.05 1.46
.001
.999 DCACTS(1)
TRUNCATED LOGNORMAL-N 6.05 1.46
.001
.999 BRTF(S8,2)
TRUNCATED LOGNORMAL-N -5.3
.9
.001
.999 BBIO(28 1)
LOGNORMAL-N 4.6 1.1 Ifi~i1f1*i1*ifffliff1f1 tfflifitffilfilliff11 tilifiiffiif11*11f11iIiffilififfffilt 1RESRAD, Version 6.5 T-Limit = 30 days 11/28/2011 10:32 Page 20 Probabilistic results summary : NB soil DCGLNi-63 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\Ni63 DCGL\\HB SOIL DCGLN163.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1
0.OOOE+00 3.454E-02 (BARTLETT Page 98
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 Np-237 Results:
1RESRAD, Version 6.5 To Limit = 30 days 11/28/2011 10:46 Page 1
Summary HB soil DCGL.Np237 File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NP237 DCGL\\HB SOIL DCGLNP237.RAD Table of Contents Part I:
Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary...
2 Site-Specific Parameter Summary............................
3 Summary of Pathway selections..............................
7 Contaminated zone and Total Dose Summary...................
8 Total Dose Components Time O.O00E+O0.......................................
9 Time 1.00O0 +O0......................................
10 Time 3.OOOE+0O......................................
11 Time 1.000E+01.....................................
12 Time 3.OO0 +O........................................
13 Time 1.O00E+02.....................................
14 Time 3.000E+02.....................................
15 Time 1.000E+03 16 Dose/Source Ratios Summed Over All Pathways...............
17 Single Radionuclide Soil Guidelines.......................
17 Dose Per Nuclide Summed Over All Pathways.................
18 Soil Concentration Per Nuclide...........................
18 IRESRAD, Version 6.5 Ta Limit = 30 days 11/28/2011 10:46 Page 2
Summary : HB soil DCGLNp237 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NP237 DCGL\\HB SOIL DCGLNP237.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: HB DCGLs Plus FGR 12 & FGR 11 0
Current Base Parameter Menu 3Paramete value#
a Case*
Name A-1 DCF's for external ground radiation, (mrem/yr)/(pCi/g)
A-1 Ac-225 (Source:
FGR 12) 6.371E-02 6.371E-02 DCFI(
1)
A-I At-217 (Source: FGR 12) 1.773E-03 1.773E-03 DCFI(
2)
A-i Bi-213 (Source: FGR 12) 7.660E-01 7.660E-01 DCF1(
3)
A-i Fr-221 (Source:
FGR 12) 1.S36E-01 1.536E-01 DCF1(
4)
A-1 a Np-237 (source: FGR 12) 7.790E-02 7.790E-02 a DCF1(
5)
A-1I Pa-233 (Source:
FGR 12) 1.020E+00 1.020E+00 a DCFI(
6)
A-1 Pb-209 (Source: FGR 12) 7.734E-04 a 7.734E-04 DCFI(
7)
A-1I Po-213 (Source: FGR 12) 0.O0OE+00 0.O0OE+00 DCFI(
8)
A-1 a Ra-225 (Source: FGR 12) 1.102E-02 a 1.102E-02 DCF1(
9)
A-1 a Th-229 (Source: FGR 12) 3.213E-01I 3.213E-01 a DCF1( 10)
A-1 31-209 (Source: FGR 12) 1.293E+01 1.293E+01 DCF1( 11)
A-1 U-233 (Source: FGR 12) 1.397E-03 1.397E-03 DCFi(
12)
B-i Dose conversion factors for inhalation, mrem/pCi:
a B-a N-237+o a S.400E-01 a 5.400E-01 DCF2(
1)
B-1 T
6 -229+D 2.169E+00 a 2.150E+00 DCF2(
2)
B-1 u-233 a 1.350E-01 1.350E-01 DCF2(
3)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Np-237+D 4.444E-03 4.440E-03 DCF3(
1)
D-1 a Th-229+D 4.027E-03 3.530E-03 a DCF3(
2)
D-1 u-233 2.890E-04 2.890E-04 DCF3(
3)
D-34 Food transfer factors:
a D-34 Np-237+D
, plant/soil concentration ratio, dimensionless a 3.670E-02 a 2.OOOE-02 RTF(
1,1)
D-34 Np-237+D beef/livestock-intake ratio, (pCi/kg)/(pci/d) a.OOOE-03 1IOOOE-03 RTF(
1,2)
D-34 Np-237+D milk/livestock-intake ratio, (pCi/L) /(pci/d) 5.OOOE-06 5.00OE-06 RTF(
1,3)
D-34 a
D-34 Th-229+D
, plant/soil concentration ratio, dimensionless a 1.OOOE-03 1.OOOE-03 RTF(
2,1)
D-34 Th-229+D beef/livestock-intake ratio, (pCi/kg)/(pCi/d)
I.OOOE-04 I.OOOE-04 RTF(
2,2)
D-34 a Th-229+D milk/livestock-intake ratio, (pCi/L) /(pCi/d) 5.OOOE-06 5.OOOE-06 RTF(
2,3)
D-34 a a
D-34 u-233
, plant/soil concentration ratio, dimensionless a 2.5OOE-03 2.500E-03 RTF(
3,1)
D-34 I u-233 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 3 3.400E-04 3.400E-04 RTF(
3,2)
D-34 a u-233 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 6.000E-04 6.OOOE-04 RTF(
3,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-53 Np-237+D
, fish 3.OOOE+01 a 3.OOOE+01 BIOFAC(
1,1)
D-5 Np-237+D
, crustacea and mollusks 4.0OOE+02 a 4.OOOE+02 BIOFAC(
1,2)
D-5 D-5 a Th-229+D
, fish 1IO00E+02 1.EOOE+02 a BIOFAC(
2,1)
D-S Th-229+D
, crustacea and mollusks S.OOOE+02 5.OOOE+02 BIOFAC(
2,2)
D-S 1
D-a U-233
, fish I 1.O00E+01 I.OOE+01 a BIOFAC(
3,1) u-5 U-233
, crustacea and mollusks a 6.OOOE+01 a 6.OOOE+01 a BIOFAC(
3,2)
- For DCFI(xxx) only factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Delault.Lib w/o Associate Nuclide contributions.
1RESRAD, Version 6.5 To Limit = 30 days 11/28/2011 10:46 Page 3
Summary : HB soil DCGLNp237 File
- C:\\RESBADFAMILY\\RESRAD\\6.5\\USERFILES\\NP237 DCGL\\HB SOIL DCGL.NP237.RAD Site-Specific Parameter Summary 0
a 3
User f used by RESRAD a Parameter Menu I Parameter a
Input p
efault (If diferent from user input) I Name ROil a Area of contaminated zone (m**2) a 3.000E+04 I 1.OOOE+O4 3 AREA R011I Thickness of contaminated zone (m) a 2.670E+00 a 2.OOOE+00 a--- THICKO ROil 3 Fraction of contamination that is submerged a O.OO0E+00 0.OOOE+0O a a-SUBMFRACT ROl Length parallel to aquifer flow (m) a 1.950E+02 a 1.OOOE+02 3 LCZPAQ ROlI Basic radiation dose limit (mrem/yr) a 2.505OE+01 3.OO0E+OI 3 BRDL ROll Time since placement of material (yr) 0.000500 3 O.OOOE+0 TI ROll Times for calculations (yr)
I1.0E+00 a 1.OOOE+00 T( 2)
ROll Times for calculations (yr) a 3.005OE+00 3.OOOE+OO T(
3)
ROll a Times for calculations (yr) a 1.0005+01 3.OOOE+0l a
T( 4)
ROil a Times for calculations (yr) a 3.OO0E+01 a 3.0OE+01 I T(
5)
R011l' Times for calculations (yr) a 1.000E+02 a 1.OOOE+02 a a T( 6)
ROll a Times for calculations (yr) 3.0OOE+02
' 3.OOOE+02 T(
7)
ROll a Times for calculations (yr) 1.OOOE+03 1.OOOE+03 a a-T( 8)
RO11 ' Times for calculations (yr) not used a 0.OOOE+0O T( 9) 40)BARTLETT Page 99
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 ROll Times for calculations (yr)
R012 3 Initial principal radionuclide (pCi/g):
Np-237 RO12 Concentration in groundwater (pCi/L):
Np-237 RO3 Cover depth (m)
RO3 Density of cover material (g/cm**3)
R013 Cover depth erosion rate (m/yr)
RO13 Density of contaminated zone (g/cm**3)
RO13 Contaminated zone erosion rate (m/yr)
R013 Contaminated zone total porosity R013 Contaminated zone field capacity R013 Contaminated zone hydraulic conductivity (m/yr)
RO13 Contaminated zone b parameter R013 Average annual wind speed (m/sec)
R013 Humidity in air (g/m**3)
R013 Evapotranspiration coefficient R013 Precipitation (m/yr)
R013 Irrigation (m/yr)
RO13 Irrigation mode R013 Runoff coefficient R013 Watershed area for nearby stream or pond (m**2)
R013 Accuracy for water/soil computations RO14 Density of saturated zone (g/cm**3)
RO14 Saturated zone total porosity RO14 Saturated zone effective porosity RO14 Saturated zone field capacity R014 Saturated zone hydraulic conductivity (m/yr)
R014 Saturated zone hydraulic gradient R014 Saturated zone b parameter R014 Water table drop rate (m/yr)
R014 Well pump intake depth (m below water table)
R014 Model: Nondispersion (ND) or Mass-Balance (MB)
R014 Well pumping rate (m**3/yr) not used 1.OOOE+00 not used 0.OOOE+00.'
not used not used 3
1.564E+00 2.200E-03 4.100E-01 9.500E-02 3.900E+00 3 5.600E+00 3.040E+00 not used 6.250E-01 9.100E-01 5.600E-01 overhead 5.OOOE-0l 2.520E+07 l.OOOE-03 1.510E+00 4.300E-01 3.420E-01 3 8.800E-02 2.880E+01 2.OOOE-03 3 7.100E+00 3 l.OOOE-03 3 1.OOOE+01
' ND 3 1.573E+03 0.000E+00 O.00E+00 0.000E+00 O.OO0E+0O 1.500E+00 1.OOOE-03 1.500E+00 l.OOOE-03 4.000E-01 2.OOOE-0O
.O00tE+01 5.300E+00 2.OOOE+00 8.O00E+OO 5.OOOE-O1 1.OOOE+00 2.000E-01 overhead 2.OOOE-01 1.OOOE+06 1.O00E-03 1.5OOE+00 4.OOOE-01 2.000E-01 2.OOOE-01 1.O00E+02 2.OOOE-02 5.300E+00 1.OOOE-03 l.OOOE+01 ND 2.500E+02 T(10)
Si(i)
W1( 1)
COVERO DENSCV vCV DENSCZ VCZ TPCZ FCCZ HCCZ BCZ WIND HUMID EVAPTR PRECIP RI IDITCH RUNOFF WAREA EPS DENSAQ TPSZ EPSZ FCSZ HCSZ HGq-r BSZ VWT DWIBWT MODEL IFS IRESRAD, Version 6.5 T. Limit = 30 days 11/28/2011 10:46 Page 4
Summary : HB soil DCGLNp237 File
- C:\\RESRAD-FAMILY\\RESRAD\\6.5\\USERFILES\\NP237 DCGL\\HB SOIL DCGLNP237.RAD site-specific Parameter Summary (continued) 0 1
3 User ffUsed by RESRAD 3
Parameter Menu 3
Parameter Input Default (I if diferent from user input)
I Name WA ROI5 Number of unsaturated zone strata 1
1 RO5 Unsat. zone 1, thickness (m) 4.040E+00 4.000E+00 R015 Unsat. zone 1, soil density (g/cm**3) 1.564E+00 1.500E+00 R015 Unsat. zone 1, total porosity 4.100E-01 4.O00E-01 R015 Unsat. zone 1, effective porosity 3.150E-01 2.000E-01 R015 Unsat. zone 1, field capacity 9.500E-02 2.000E-01 R015 Unsat. zone 1, soil-specific b parameter 5.600E+00 5.300E+00 R015 Unsat. zone 1, hydraulic conductivity (m/yr) 3.900E+00 1.00OE+01 R016 Distribution coefficients for Np-237 ROI6 Contaminated zone (cm**3/g) 1.700E+01 :-1.00OE+00 R016 unsaturated zone I (cm**3/g) 1.700E+01 -- I.000E+00 RO6 Saturated zone (cm**3/g) 1.700E+01 1-1.OO0E+00 R016 Leach rate (/yr)
O.00E+0O O.O0OE+00 RO16 Solubility constant O.O00E+OO 0.000E+00 R016 Distribution coefficients for daughter Th-229 R016 Contaminated zone (cm**3/g) 5.884E+03 6.000E+04 R016 3 Unsaturated zone 1 (cm**3/g) 5.884E+03 I 6.000E+04 R016 Saturated zone (cm**3/g) 5.884E+03 6.000E+04 R016 Leach rate (/yr) 0.O00E+0O O.00OE+00 R016 Solubility constant 0.OOOE+00 O.000E+OO R016 Distribution coefficients for daughter U-233 RO6 Contaminated zone (cm**3/g) 1.260E+02 5.OOOE+01 R016 unsaturated zone 1 (cm**3/g) 1.260E+02 5.OOOE+01 R016 Saturated zone (cm**3/g) 1.260E+02 5.000E+01 R016 Leach rate (/yr) 0.OO0E+00 0.OOOE+00 R016 Solubility constant O.000E+0O 0.OOOE+00 R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 R017 Mass loading for inhalation Cg/m**3) 1.000E-04 1.000E-04 R017 Exposure duration 3.000E+O1 3.000E+01 R017 Shielding factor, inhalation 5.500E-01 4.0OOE-01 R017 Shielding factor, external gamma 2.725E-01 7.0OOE-01 R017 Fraction of time spent indoors 6.571E-01 5.00OE-01 R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 R017 Shape factor flag, external gamma 1.000E+00 1.OOOE+00 IRESRAD, Version 6.5 T<' Limit = 30 days 11/28/2011 10:46 Page 5
Summary : HB soil DCGL-Np237 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NP237 DCGL\\HB SOIL DCGLNP237.RAD NS SM(1)
DENSUZ(1)
TPUZ(1)
EPUZ(1) 3 FCUZ(1)
BUZ(1)
HCUZ(1) 5.294E-03 not used 1.550E-05 not used 7.224E-04 not used
>0 shows circular AREA.
DCNUCC( 1)
DCNUCU( 1,1)
DCNUCS(
1)
ALEACH( 1)
SOLUBK(
1)
DCNUCC(
2)
DCNUCU( 2,1)
DCNUCS( 2)
ALEACH 2)
SOLUBK(
2) 3 DCNUCC(
3)
DCNUCU( 3,1)
DCNUCS( 3)
ALEACH(
3)
SOLUBK(
3)
INHALR MLINH 3 ED SHF3 SHF1 FIND FOTD 3 FS 0
menu Paaee R017 Radii of shape factor array (used R017 Outer annular radius (m),
ring R017 Outer annular radius (m),
ring R017 Outer annular radius (m),
ring R017 Outer annular radius (m),
ring R017 Outer annular radius (m),
ring R017 Outer annular radius (m),
ring R017 Outer annular radius (m),
ring R017 Outer annular radius (m),
ring R017 Outer annular radius (m),
ring R017 Outer annular radius (m),
ring 1 R017 Outer annular radius (m),
ring 1 R017 Outer annular radius (m),
ring 1 R017 Fractions of annular areas within R017 Ring 1
R017 Ring 2
R017 Ring 3
R017 Ring 4
R017 Ring R017 Ring 6 tSBARTLETT site-specific Parameter Summary (continued)
User I
Used by RESRAD Parameter Input Default,3 (If different frqomýser.inpqý)
Name if FS
-1):
3 1:
not used 5.000E+01 RAD.SHAPE(
3 2:
not used 7.071E+01 RAD.SHAPE(
3:
not used 0.OOOE+00 RADSHAPE(
3 4:
not used 0.000+00 RADSHAPE(
5:
not used O.OOOE+0O RADSHAPE(
6:
not used O.000E+00 RADSHAPE(
7:
not used 0.000E+O0 RADSHAPE(
6 8:
' not used 30.OO0E+00 3---
3 RAD-.SHAPE(7 9:
not used O.00OE+00
- RAD-SHAPE(
0:
not used O.0OOE+00 RADSHAPE1(C 1:
not used 0.OOOE+00 RADSHAPE(1l 2:
not used O.00OE+00 RADSHAPE(I2 AREA:
not used 1.000E+00 FRACA( 1) not used 2.732E-01 PRACA( 2) not used O.OOOE+00 FRACA( 3) not used O.000E+00 FRACA( 4) not used O.000E+0O FRACA( 5) not used 3 0. NNnrA 3 a
3 ArA(
Al 2) 3)
s) 6)
9)
Page 100
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R017 Ring 7
not used 0.0000E+0 RO17 Ring 8
not used 0.006E+00 RO17 Ring 9
not used O.O00E+00 RO17 Ring 10 not used O.O000E00 RO17 Ring 11 not used O.0OOE+00 RO17
- Ring 12 not used 0.00OE+00 R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 RO18 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 RO18 Milk consumption (L/yr) 2.330E+02 9.200E+01 RO18 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 RO18 Fish consumption (kg/yr) 2.060E+01 5.400E+00 R018 other seafood consumption (kg/yr) 9.OOOE-01 9.000E-01 R018 3 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 RO18 3 Drinking water intake (L/yr) 4.785E+02 5.100E+02 RO18 Contamination fraction of drinking water 1.OOE+O0 1.O00E+00 RO18 Contamination fraction of household water not used 1.000E+00 RO18 Contamination fraction of livestock water 1.OO0E+-00 1.O0006O0 RO18 Contamination fraction of irrigation water 1.000E+00 1.0006E+0 RO18 Contamination fraction of aquatic food 1.O00E+00 5.000E-01 R018 Contamination fraction of plant food 1.000E+O0 3-1 R018 Contamination fraction of meat 1.000E+00 '-1 R018 Contamination fraction of milk 1.OOOE+00 :-1 RO9 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 RO19 Livestock water intake for meat (L/day)
I 5.060E+01 5.000E+01 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 RO19 Livestock soil intake (kg/day) 5.000E-01 5.OOOE-01
- 1RESRAD, Version 6.5 T-Limit = 30 days 11/28/2011 10:46 Page 6
Summary : HB soil DCGLNp237 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NP237 DCGL\\HB SOIL DCGLNP237.RAD Site-Specific Parameter Summary (continu 0
User 3
Menu 3.
Parameter........................................
I.......
P.ut.... Default ROI9 Mass loading for foliar deposition (g/m**3) 4.OOOE-04 I1.00E-04 ROt9 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 R019 Depth of roots (m) 1.220E+00 9.00OE-01 R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 R019 Household water fraction from ground water not used 1.00OE+0I R019 Livestock water fraction from ground water 1.000E+00 1.OOOE+00 R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 R19i Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.OOOE-01 R19B Wet weight crop yield for Leafy (kg/m*-2) 2.889E+00 1.500E+00 R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 R19B Growing season for Non-Leafy (years) 2.460E-01 1.700E-01 R19i Growing Season for Leafy (years) 1.230E-01 2.500E-01 Ri9B Growing Season for Fodder (years) 8.200E-02 8.OOOE-02 R19B Translocation Factor for Non-Leafy 1.000E-01 1.00OE-01 RisB Translocation Factor for Leafy 1.000E+00 1.000E+00 Ri9B Translocation Factor for Fodder 1.OOOE+00 1.000E+00 Ri9e Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 Ri1B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 Ri9B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 R19i Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 ResB Weathering Removal Constant for vegetation 3.300E+01 2.0000E+1 C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 C14 3 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 C14 Fraction of vegetation carbon from soil not used 2.00OE-02 C14 3 Fraction of vegetation carbon from air not used 9.800E-01 C14 3 C-14 evasion layer thickness in soil (m) not used 3.000E-01 C14 I C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 C14 3 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 C14 Fraction of grain in beef cattle feed not used 8.OOOE-01 C14 Fraction of grain in milk cow feed not used 2.000E-01 STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 STOR Leafy vegetables 1.000E+00 1.000E+00 STOR Milk 1.000E+00 1.O00E+00 STOe Meat and poultry 2.000E+01 2.000E+O1 STOR Fish 7.000E+00 7.000E+00 STOR Crustacea and mollusks I 7.000E+00 7.OOOE+00 STOR Well water 1.000E+00 1.O00E+00 STOR Surface water 1.000E+00 1.000E+O0 STOR Livestock fodder 4.500E+01 4.500E+01 R021 Thickness of building foundation (m) 3 not used 1.500E-01 R021 Bulk density of building foundation (g/cm**3) not used I 2.400E+00 R021 Total porosity of the cover material not used 4.000E-01 R021 Total porosity of the building foundation not used I 1.000E-01 1RESRAD, Version 6.5 T. Limit = 30 days 11/28/2011 10:46 Page 7
Summary : HB soil DCGLNp237 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NP237 DCGL\\HB SOIL DCGLNP237.RAD ed) used by RESRAD CIf different from User input)
XXWXXXXXX*AAAAAAa..p)
' FRACA( 7) 3 FRACA( 8)
FRACAC 9)
FRACA(IO)
FRACA(11)
FRACA(12)
DIET(l)
DIET(2)
DIET(3)
DIET(4)
DIET(5)
DIET(6)
SOIL DWI FDW FHHW FLW FIRW FR9 FPLANT FMEAT FMILK 3 LFIS 3 LFI6 3 LWI S LWI 6
' LSI Parameter Name MLFD 3DM DROOT 3 FGWOW
' FGWHH 3 FGWLW FGWIR YV(1)
YV(2)
YV(3)
TE(1)
TE(2)
TE(3)
TIV(1)
TIV(2)
TIV(3)
RDRY(1)
RDRY(2) 3 RDRY(3)
RWET(1)
RWET(2) 3 RWET(3)
WLAM C12WTR C12CZ CSOIL
- CAIR DMC 3 EVSN REVSN AVFG4 AVFG5 STOR-T(1)
STORT(2)
STORT(3)
STORT(4)
STORT(5)
STORT(6)
SToR_T(7)
STORT(8)
STORST(9)
FLOORI DENSFL TPCV TPFL AAA Site-Specific Parameter Summary (continued)
User 3
Used by RESRAD Parameter 0
Menu 3
.Parameter Input Default R021 Volumetric water content of the cover material not used 5.0006-02 R021 Volumetric water content of the foundation not used 3.000E-02 R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 R021 in foundation material 3 not used 3 3.000E-07 R021 in contaminated zone soil not used 2.000E-06 R021 Radon vertical dimension of mixing (m) not used 3 2.000E+00 R021 Average building air exchange rate (1/hr) 3 not used S.OOE-01 R021 Height of the building (room)
(m) not used 2.500E+00 R021 Building interior area factor not used
'.000E+00 R021 Building depth below ground surface (m) not used
-1.O000E+00 R021 3 Emanating power of Rn-222 gas not used 3 2.500E-01 R021 Emanating power of Rn-220 gas not used 3 1.500E-01 TITL Number of graphical time points 32 TITL Maximum number of integration points for dose 17 3
Q SBARTL E TT (If different from user input) 3 Name 3
3 3
3 PH2OCV PH2OFL DIFCV DIFFL DIFCZ HMIX REXG HRM FAI DMFL 3 EMANA(1)
- EMANA(2)
NPTS LYMAX Page 101
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 TITL 3 Maximum number of integration points for risk k 1
3 KYMAX Summary of Pathway selections twy 3
Us.er Se ct.ion.....
1-- external gamma 3
active 2
inhalation (w/o radon) 3 active 3-- plant ingestion 3
active 4
meat ingestion active 5
milk ingestion active 6
aquatic foods active 7-- drinking water active 8
soil ingestion active 9 --
radon suppressed Find peak pathway doses active 1RESRAD, Version 6.5 T` Limit = 30 days 11/28/2011 10:46 Page 8
Summary : HB soil DCGLNp237 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NP237 DCGL\\HB SOIL DCGLNP237.RAD Contaminated zone Dimensions Initial Soil Concentrations, pci/g Area:
30000.00 square meters Np-237 1.OO0E+00 Thickness:
2.67 meters Cover Depth:
0.00 meters 1RESRAD, Version 6.5 T< Limit = 30 days 11/28/2011 10:46 Page I
Probabilistic results summary : HB soil DCGL-Np237 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NP237 DCGL\\HB SOIL DCGLNP237.RAD Table of Contents Part VI: Uncertainty Analysis ORESRAD Uncertainty Analysis Results Probabilistic Input.................................
2 Total Dose.................
3 Total Risk.................
4 Dose vs Pathway:
Ground External....................
Dose vs Pathway:
Inhalation (w/o Radon)............
.6 Dose vs Pathway:
Radon (Water Ind.)
7 Dose vs Pathway:
Plant (Water Ind.).................
8 Dose vs Pathway:
Meat (water Ind.)................
9 Dose vs Pathway:
Milk (water Ind.)
10 Dose vs Pathway:
Soil Ingestion.....................11 Dose vs Pathway:
water Ingestion....................
12 Dose vs Pathway:
Fish Ingestion.....................
13 Dose vs Pathway:
Radon (Water Dep.)
14 Dose vs Pathway:
Plant (Water Dep.)
15 Dose vs Pathway:
Meat (Water Dep.).................
16 Dose vs Pathway:
Milk (Water Dep.)
17 Cumulative Probability Summary.......................
18 summary of dose at graphical times, reptition 1...
19 Peak of the mean dose at graphical times.............
20 Correlation and Regression coefficients (if any).....
21 1RESRAD, Version 6.5 Ta Limit = 30 days 11/28/2011 10:46 Page 2
Probabilistic results summary : HB soil DCGL_.Np237 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NP237 DCGL\\HB SOIL DCGLNP237.RAD Probabilist ONumber of Sample Runs: 2000 Number Name AAAWJUU'JAAXXXXXXXXXAXXXXXXX 1
DENSCZ 2
TPCZ 3
HCCZ 4
BCZ 5
EVAPTR 6
RI 7
DENSAQ 8
TPSZ 9
EPSZ 10 HCSZ 11 BSZ 12 DWIBWT 13 UW 14 H(1) 15 DENSUZ(1) 16 TPUZ(1) 17 EPUZ(1) 18 HCUZ(1) 19 BUZ(1) 20 MLINH
.00003
.8119
.00004 21 SHF3 22 SHF1 23 DM 24 YV(1) 25 WLAM 26 RWET(2) 27 DCACTC(1) 28 DCACTUI(1) 29 DCACTS(1) 30 DCACTC(2) 31 DCACTU1(2) 32 DCACTS(2) 33 DCACTC(3) 34 DCACTU1(3) 35 DCACTS(3) 36 BRTF(93,2) 37 BRTF(93,3) 38 BBIO(93,1) 39 BRTF(90,1) 40 BRTF(90,2) ic Input Distribution Parameters BOUNDED NORMAL 1.5635
.2385
.827 2.3 BOUNDED NORMAL
.41
.09
.1319
.6881 BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 UNIFORM
.5
.75 UNIFORM
.36
.76 BOUNDED NORMAL 1.5105
.1855
.937 2.084 BOUNDED NORMAL
.43
.0699
.214
.646 BOUNDED NORMAL
.342
.0705
.124
.56 BOUNDED LOGNORMAL-N.362 1.59
.0106 195 BOUNDED LOGNORMAL-N 1.96
.265 3.02 15.5 TRIANGULAR 6
10 30 UNIFORM 1173 1973 UNIFORM 0
8.08 BOUNDED NORMAL 1.5635
.2385
.827 2.3 BOUNDED NORMAL
.41
.09
.1319
.6881 BOUNDED NORMAL
.315
.0905
.0349
.594 BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 CONTINUOUS LINEAR 8
0 0
.000008
.9495
.00006
.9937
.000076
.9983
.0001 1
UNIFORM
.15
.9S BOUNDED LOGNORMAL-N -1.3
.59
.044 1
TRIANGULAR 0
.15
.6 TRUNCATED LOGNORMAL-N
.56
.48
.001
.999 TRIANGULAR 5.1 18 84 TRIANGULAR
.06
.67
.95 TRUNCATED LOGNORMAL-N 2.84 2.25
.001
.999 TRUNCATED LOGNORMAL-N 2.84 2.25
.001
.999 TRUNCATED LOGNORMAL-N 2.84 2.25
.001
.999 TRUNCATED LOGNORMAL-N 8.68 3.62
.001
.999 TRUNCATED LOGNORMAL-N 8.68 3.62
.001
.999 TRUNCATED LOGNORMAL-N 8.68 3.62
.001
.999 TRUNCATED LOGNORMAL-N 4.84 3.13
.001
.999 TRUNCATED LOGNORMAL-N 4.84 3.13
.001
.999 TRUNCATED LOGNORMAL-N 4.84 3.13
.001
.999 TRUNCATED LOGNORMAL-N -6.91
.7
.001
.999 TRUNCATED LOGNORMAL-N -11.51
.7
.001
.999 LOGNORMAL-N 3.4 1.1 TRUNCATED LOGNORMAL-N -6.91
.9
.001
.999 TRUNCATED LOGNORMAL-N -9.21 1
.001
.999
.0151
.000016
.1365
~g~SARTLETT Page 102 IBARTLETT Page 102
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 41 BRTF(90,3) 42 8BIO(90,1) 43 BRTF(92,1) 44 BRTF(92,2) 45 BRTF(92,3) 46 BBIO(92 1) ftltft 11ttttttttittllttntttt TRUNCATED LOGNORMAL-N -12.21
.9
.001
.999 LOGNORMAL-N 4.6 1.1 TRUNCATED LOGNORMAL-N -6.21
.9
.001
.999 TRUNCATED LOGNORMAL-N -7.13
.7
.001
.999 TRUNCATED LOGNORMAL-N -7.82
.6
.001
.999 LOGNORMAL-N 2.3 1.1 fttft~tftt1tttttt tttttt fttttff tltiffiffflttttttffftfftittIttlt 1RESRAD, Version 6.5 To Limit = 30 days 11/28/2011 10:46 Page 20 Probabilistic results summary : HB soil DCGLNp237 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\NP237 DCGL\\HB SOIL DCGLJNP237.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1
0.000E+00 2.248E+01 V
BARTLETT Page 103
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 Pu-238 Results:
IRESRAD, version 6.5 T` Limit = 30 days 11/28/2011 10:55 Page 1
Summary : HB soil DCGLPu-238 File
- C:\\RESRAD-FAMILY\\RESRAD\\6.5\\USERFILES\\PU238 DCGL\\HB SOIL DCGL_PU238.RAD Table of Contents Part I: Mixture Sums and Sinqle Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary...
2 site-Specific Parameter Summary............................
4 Summary of Pathway Selections.............................
8 Contaminated Zone and Total Dose Summary................... 9 Total Dose Components Time = O.O00E+00.....................................
10 Time = 1.0OOE+00.....................................
11 Time = 3.000E+00.....................................
12 Time = 1.000E+01....................................
13 Time = 3.000E+01.....................................
14 Time = 1.000E+02.
15 Time = 3.000E+02.
16 Time = 1.000E+03..
17 Dose/Source Ratios Summed Over All Pathways..............
18 single Radionuclide Soil Guidelines......................
18 Dose Per Nuclide Summed over All Pathways................
19 Soil Concentration Per Nuclide...........................
19 iRESRAD, Version 6.5 T-Limit = 30 days 11/28/2011 10:35 Page 2
Summary : HB soil DCGL-Pu-238 File
- C:\\RESRADFAMILY\\REsRAD\\6.S\\USERFILES\\Pu238 DCGL\\HB SOIL DCGLPU238.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: HB DCGLS Plus FGR 12 & FGR 11 0
Current Base Parameter Menu.3 Parameter value#
Caset Name A-i DCF's for external ground radiation, (mrem/yr)/(pCi/g)
A-1 At-218 (Source:
FGR 12) 5.847E-03 5.847E-03 DCF1(
1)
A-1 Bi-210 (Source: FGR 12) 3.606E-03 3.606E-03 DCF1(
2)
A-1 Bi-214 (Source:
FGR 12) 9.808E+00 9.808E+00 DCF1(
3)
A-1 Pb-210 (Source: FGR 12) 2.447E-03 2.447E-03 DCF1(
4)
A-1 Pb-214 (Source:
FGR 12) 1.341E+00 1.341E+00 DCF1(
5)
A-i Po-210 (Source: FGR 12) 5.231E-05 5.231E-05 DCFI(
6)
A-1 Po-214 (Source:
FGR 12) 5.138E-04 5.138E-04 DCF1(
7)
A-1 Po-218 (Source:
FGR 12) 5.642E-05 5.642E-05 DCFi(
8)
A-I Pu-238 (Source:
FGR 12) 1.513E-04 1.513E-04 DCF1(
9)
A-I Ra-226 (Source:
FGR 12) 3.176E-02 3.176E-02 DCF1( 10)
A-I Rn-222 (Source:
FGR 12) 2.354E-03 2.354E-03 DCF1( II)
A-1 Th-230 (Source:
FGR 12) 1.209E-03 1.209E-03 DCFI(
12)
A-1 TI-210 (Source: no data)
O.000E+00 1-2.000E+00 DCFi( 13)
A-1 U-234 (Source: FGR 12) 4.017E-04 4.017E-04 DCFI(
14)
B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Pb-210+D 1.380E-02 1.360E-02 DCF2(
1)
B-1 Po-210 9.400E-03 9.400E-03 DCF2(
2)
B-I Pu-238 3.920E-01 3.920E-01 DCF2(
3)
B-I Ra-226+D 8.594E-03 8.580E-03 DCF2(
5)
B-1 Th-230 3.260E-01I 3.260E-01 DCF2(
6)
B-1 u-234 1.320E-01 1.320E-01 DCF2(
7)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Pb-210+D 5.376E-03 S.370E-03 DCF3(
1)
D-1 Po-210 1.900E-03 1.900E-03 DCF3(
2)
D-1 Pu-238 3.200E-03 3.200E-03 DCF3(
3)
D-1 Ra-226+D 1.321E-03 1.320E-03 DCF3(
5)
D-1 Th-230 5.480E-04 5.480E-04 DCF3(
6)
D-1 u-234 2.830E-04 2.830E-04 DCF3(
7)
D-34 3 Food transfer factors:
3 D-34 3 Pb-210+D plant/soil concentration ratio, dimensionless 1.OOOE-02 1.OOOE-02 RTF(
1,1)
D-34 Pb-210+9 beef/livestock-intake ratio, (pCi/kg)/(pci/d) 8.000E-04 I 8.000E-04 RTF(
1,2)
D-34 I Pb-210+D milk/livestock-intake ratio, (pCi/L)/(pci/d) 3.OOOE-04 3.000E-04 RTF(
1,3)
D-34 3 D-34 Po-210 plant/soil concentration ratio, dimensionless 1.OOOE-03 1.OOOE-03 RTF(
2,1)
D-34 Po-210 beef/livestock-intake ratio, (pCi/kg)/(pci/d) 5.000E-03 5.O00E-03 RTF(
2,2)
D-34 Po-210 milk/livestock-intake ratio, (pCi/L) /(pci/d) 3.400E-04 3.400E-04 RTF(
2,3)
D-34 D-34 Pu-238
, Dlant/soil concentration ratio, dimensionless I1.830E-03 1.000E-03 RTF(
3,1)
D-34 Pu-238 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-04 1.OOOE-04 RTF(
3,2)
D-34 Pu-238 milk/livestock-intake ratio, (pCi/L)/(pci/d) 1.OOOE-06 1.OOOE-06 RTF(
3,3)
D-34 3 D-34 Ra-226+D p lant/soil concentration ratio, dimensionless 4.OOOE-02 4.000E-02 RTF(
5,1)
D-34 Ra-226+D beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-03 1.000E-03 RTF(
5,2)
D-34 Ra-226+D milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.000E-03 1.000E-03 RTF(
5,3)
D-343 1RESRAD, Version 6.5 T-Limit = 30 days 11/28/2011 10:55 Page 3
Summary : HB soil DCGLPU-238 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU238 DCGL\\HB SOIL DCGL_PU238.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)
Dose Library: HB DCGLs Plus FGR 12 & FGR 11 0
1 Current e
Base 3 Parameter Menu value#
Case 3
I N
.am D-34 Th-230
, plant/soil concentration ratio, dimensionless 1.000E-03 1.OOOE-03 RTF(
6,1)
D-34 Th-230 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000-04 1.OOOE-04 RTF(
6,2)
D-34 Th-230 milk/livestock-intake ratio, (pCi/L) /(pCi/d) 5.000E-06 5.OOOE-06 RTF(
6,3)
D-34 D-34 u-234
, plant/soil concentration ratio, dimensionless 2.500E-03 2.50OE-03 RTF(
7,1)
D-34 u-234 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 3.400E-04 3.400E-04 RTF(
7,2)
D-34 u-234 milk/livestock-intake ratio, (pCi/L) /(pci/d) 6.000-E04 6.OOOE-04 RTF(
7,3)
D-S Bioaccumulation factors, fresh water, L/kg:
D-5 Pb-210+D
, fish 3.000E+02 3.OOOE+02 BIOFAC(
1,I)
D-S Pb-210+D
, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC(
1,2)
D-S D-S Po-210
, fish 1.000E+02 1.O00E+02 BIOFAC(
2,1) tBARTLETT Page 104
Bartlett Engineering U.h,nmhnlfIr:t u
PmSniI lll I c' ENG-HB-003 Rev. 0 D-S Po-210
, crustacea and mollusks 2.00OE+04 2.OOOE+04 : BIOFAC(
2,2)
D-5 o-5 Pu-238 fish 3.OOOE+01 3.OOOE+O1 BIOFAC(
3,1)
D-S Pu-238 crustacea and mollusks 1.000E+02 1.OOOE+02 BIOFAC(
3,2)
D-5 3
1 D-5 3 Ra-226+D fish S.OOOE+Ol 5.OOOE+01 BIOFAC(
5.1)
D-5 Ra-226+D crustacea and mollusks 2.500E+02 2.500E+02 BIOFAC(
5,2)
D-S D-5 Th-230 fish 1.OOOE+02 1.OOOE+02 BIOFAC(
6,1)
D-5 3 Th-230 crustacea and mollusks 5.000E+02 5.OOOE+02 BIOFAC(
6,2)
D-5 3
1 3 D-5 u-234 fish 1.000E+01 1.OOOE+0l BIOFAC(
7,1)
D-5 u-234 crustacea and mollusks 6.OOOE+01 6.ooOE+Ol BIOFAC(
7,2)
- For DCFl(xxx) only, factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
t Base Case means Default.Lib w/o Associate Nuclide contributions.
1RESRAD, Version 6.5 Ti Limit = 30 days 11/28/2011 10:55 Page 4
Summary HB soil DCGLPu-238 File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU 2 38 DCGL\\HB SOIL DCGL_PU238.RAD 0
Menu site-Specific Parameter Summary User 3 input....
..Default..'.
Parameter kk~kxaxxsxxxxxxxxxXXXXXXXXXXiXXXXXXXXXXXAaAAAAA R011 Area of contaminated zone (m**2) 3.UOOE+U4 I 1.UUUE+U4 R011 Thickness of contaminated zone (m) 2.670E+00 2.OOOE+0O R011 Fraction of contamination that is submerged
' 0.OOOE+00 0.OOOE+00 R011 Length parallel to aquifer flow (m) 1.950E+02 1.OOOE+02 ROll Basic radiation dose limit (mrem/yr) 2.500E+01 3.OOOE+01 ROll Time since placement of material (yr)
O.OOOE+00 O.OOOE+0O R011 Times for calculations (yr) 1.OOOE+00 1.OOOE+00 R011 Times for calculations (yr) 3.OOOE+00 3.OOOE+00 R011 Times for calculations (yr) 1.000E+01 1.OOOE+01 R011 Times for calculations (yr) 3.OOOE+01 3.000E+01 R011 Times for calculations (yr) 1.000E+02 1.OOOE+02 R011 Times for calculations (yr) 3.OOOE+02 3.000E+02 R011 Times for calculations (yr) 1.0OOE+03 I1.OOOE+03 R011 Times for calculations (yr) not used O.0OOE++OO R011 Times for calculations (yr) not used O.OOOE+0O R012 Initial principal radionuclide (pCi/g):
Pu-238 3 1.OOOE+O0 O.OOOE+00 R012 Concentration in groundwater (pCi/L):
Pu-238 not used O.OOOE+00 RO13 Cover depth (m) 0.OOOE+00 O.0OOE+0O R013 Density of cover material (g/cm**3) 3 not used 1.500E+00 R013 Cover depth erosion rate (m/yr) not used
- l. OOOE-03 R013 Density of contaminated zone (g/cm**3) 1.564E+00 1.500E+00 R013 Contaminated zone erosion rate (m/yr) 2.200E-03 1.000E-03 R013 Contaminated zone total porosity 4.100E-01 4.OOOE-01 R013 Contaminated zone field capacity 9.500E-02 2.OOOE-01 R013 Contaminated zone hydraulic conductivity (m/yr) 3.900E+00 1.OOOE+01 RO13 Contaminated zone b parameter 5.600E+00 5.300E+00 ROl3 Average annual wind speed (m/sec) 3.040E+00 2.OOOE+00 R013 Humidity in air (g/m**3) not used 8.000E+00 RO33 Evapotranspiration coefficient 6.250E-01 5.OOOE-01 R13 3Precipitation (m/yr) 9.100E-01 1.OOOE+O0 R013 PIrrigation (m/yr) 5.600E-01 2.OOOE-01 R013 Irrigation m/de r overhead overhead ROl3 Runoff coefficient 5.OOOE-01 2.OOOE-01 R013 watershed area for nearby stream or pond (m**2) 2.520E+07 I.OOOE+06 ROl3 Accuracy for water/soil computations 1.OOOE-03 I.OOOE-03 3
3 3
3 R014 Density of saturated zone (g/cm**3) 1.510E+00 I1.500E+00 R014 Saturated zone total porosity 4.300E-01 4.OOOE-01 R014 Saturated zone effective porosity 3.420E-01 2.00OE-01 R014 Saturated zone field capacity 8.800E-02 2.0OOE-01 R014 Saturated zone hydraulic conductivity (m/yr) 2.880E+01 1.000E+02 R014 Saturated zone hydraulic gradient 2.OOOE-03 2.OOOE-02 R014 Saturated zone b parameter 7.100E+00 5.3OOE+00 R014 water table drop rate (m/yr) 1.OOOE-03 I.OOOE-03 R014 well pump intake depth (m below water table) 1.OOOE+01 1.OOOE+01 R014 Model: Nondispersion (ND) or Mass-Balance (MB) 3 ND ND R014 well pumping rate (m**3/yr) 1.573E+03 2.500E+02
- 1RESRAD, Version 6.5 7T Limit = 30 days 11/28/2011 10:55 Page 5
Summary : HB soil DCGL-PU-238 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU 2 38 DCGL\\HB SOIL DCGLPU238.RAD Used by RESRAD Parameter if different from user input)
Name xxxxxaxxx~xxxxxxxxixXXAXXXXAAAAAAA AREA
-- THICKO 3 SUBMFRACT 3 LCZPAQ 3 BRDL
- -TI mIT( 2) 3 CT(
3) 3 T( 4) 3-T(5)
- T(
6)
-- T(
7)
-CT( 8) 3 T(
9) 3 T(10) sl(3)
-- wl( 3)
COVERO DENSCV 3 VCV DENSCZ VCZ TPCZ FCCZ
-- HCCZ BCZ WIND HUMID EVAPTR 3 PRECIP RI IDITCH RUNOFF WAREA 3 EPS DENSAQ 3 TPSZ
-- EPSZ 3 FCSZ 3 HCSZ
-- HGWT BSZ 3-VWT
-3 DWI BWl-3-MODEL UW 3Vw Site-Specific Parameter Summary (continued) 0 3
User used by RESRAD Parameter menu Parameter Input Default (If different from user input)...... Name............
ROI5 Number of unsaturated zone strata 1
1 NS R01S Unsat. zone 1, thickness (m) 4.040E+00 4,O00E+00 H(1)
RO15 Unsat. zone 1, soil density (g/cm**3) 1.564E+00 1.SOOE+-0 DENSUZ(1)
R01S Unsat. zone 1, total porosity 4.100E-01 4.0005-01 TPUZ(1)
RO15 Unsat. zone 1, effective porosity 3.150E-01 2.OOOE-01 EPUZ(1)
R015 unsat. zone 1: field capacity 9.500E-02 2.0OOE-01
- FCUZ(1)
R0l5 Unsat. zone 1, soil-specific b parameter 5.600E+00 5.3OOE+00 BUZ(1)
ROlS Unsat. zone 1, hydraulic conductivity (m/yr) 3.900E+O0 l.OOOE+01 HCUZ(1)
R016 Distribution coefficients for Pu-238 RO16 Contaminated zone (cm**3/)
9.530E+02 2.OOOE+03 DCNUCC( 3)
R016 Unsaturated zone 1 (cmW-3&g) 9.530E+02 2.OOOE+03 DCNUCU( 3,1)
R016 Saturated zone (cm**3/g) 9.530E+02 2.000E+03 DCNUCSC( 3)
R016 Leach rate (/yr) 0.000E+00 O.OOO3+O0 9.565E-05 ALEACH(3)
R016 Solubility constant O.OOOE+00 O.00OE+OO not used SOLUBK( 3)
R016 Distribution coefficients for daughter Pb-210 3
R016 Contaminated zone (cm**3/g) 2.392E+03 1.000E+02 DCNUCC( 1)
R016 Unsaturated zone 1 (cm**3/g) 2.392E+03 1.OOOE+02 DCNUCUC1.1)
R016 Saturated zone (cm*
3/g) 2.392E+03 1.OOOE+02 DCNUCS( 1)
R016 Leach rate (/yr)
O.OOOE+O0 0.OOOE+00 3.811E-05 ALEACH( 1)
R016 Solubility constant O.OOOE+OO 0.OOOE+O0 not used SOLUBK( 1)
R016 Distribution coefficients for daughter Po-210 R016 I Contaminated zone (cm**3/g) 1.810E+02 1.OOOE+01 DCNUCC( 2)
R016 Unsaturated zone 1 (cm**3/g) 1.810E+02 1.OOOE+0I DCNUCU( 2,1)
R016 Saturated zone 1.810E+02 1.OOOE+01 DCNUCS( 2)
R016 Leach rate (/yr) c
.O00E+00 O.OOOE+OO 5.031E-04 AL3ACHC2)
R016 solubility constant 0.OOOE+00 O.OOOE+00 not used SOLUBK( 2) fBARTLETT Page 105
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R016
- Distribution coefficients for daughter Ra-226 R016 Contaminated zone (cm**3/g) 3.533E+03 7.000E+01 R016 Unsaturated zone 1 (cm**3/g) 3.533E+03 7.000E+01 R016 Saturated zone (cm**3/g) 3.533E+03 7.000E+01 RO16 Leach rate'(/yr)
O.OOOE+00 O.O00E+00 R016 solubility'constant O.OOOE+00 0.000+00 R016 Distribution coefficients for daughter Th-230 RO16 contaminated zone (cn**3/g) 5.884E+03 6.000E+04 R016 unsaturated zone 1 (cm*3/g) 5.884E+03 6.000E+04 R016 Saturated zone (cm**3/g) 5.884E+03 6.OOOE+04 R016 Leach rate (/yr)
O.000E+00 O.O00E+00 R016 solubility constant O.O00E+00 O.OOOE+O0 R016 Distribution coefficients for daughter U-234 R016 Contaminated zone (cm**3/g) 1.260E+02 5.300E+01 R016 Unsaturated zone 1 (cm*3/g) 1.260E+02 5.000E+01 R016 Saturated zone (cm**3/g) 1.260E+02 5.000E+01 R016 Leach rate (/yr)
O.000E+00 O.OOOE+00 R016 solubility constant O.000E+00 O.O00E+00
- IRESRAD, Version 6.5 T" Limit = 30 days 11/28/2011 10:55 Page 6
Summary : HB soil DCGLCPu-238 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILEs\\Pu238 DCGL\\HR SOIL DCGLPU238.RAD 2.581E-05 not used 1.550E-05 not used 7.224E-04 not used 0
Menu site-specific Parameter summary (continu User Input Default
....... A...
P.a me t
RO17 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 R017 Mass loading for inhalation (g/m**3)
.O000E-04 1.000E-04 R017 Exposure duration I 3.000E+01 3,000E+01 R017 Shielding factor, inhalation 5.500E-01 4.000E-01 R017 shielding factor, external gamma 2.725E-01 7.000E-01 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 R017 Shape factor flag, external gamma 1.O00E+00 1.000E+00 R017 Radii of shape factor array (used if FS = -1):
R017 3 Outer annular radius (m),
ring 1:
not used 5.0008+01 R017 Outer annular radius (m), ring 2:
not used 7.071E+01 R017 Outer annular radius (m),
ring 3:
not used
,07.0E+00 R017 Outer annular radius (m),
ring 4:
not used O.0008E+0 ROl7 Outer annular radius (m),
ring 5:
not used 0.000E+00 R017 Outer annular radius (m),
ring 6:
not used O.00OE+00 R017 Outer annular radius (m),
ring 7:
not used 0.OOOE+00 R017 Outer annular radius Wm) ring 8:
not used 0.oOOE+O0 ROll Outer annular radius (m),
ring 9:
not used 0.OOOE+00 R017 Outer annular radius Cm) ring 10:
not used O.OOOE+00 R017 Outer annular radius (m),
ring 11:
not used O.OOOE+00 R017 Outer annular radius (m),
ring 12:
not used 0.OOOE+00 R017 Fractions of annular areas within AREA:
R017 Ring 1
not used 1.00OE+00 R017 Ring 2
not used 2.732E-01 R017 Ring 3
not used 0.000E+00 R017 Ring 4
not used O.OOOE+00 R017 Ring 5
not used O.O00E+00 R017 Ring 6
not used O.OOOE+00 R017 Ring 7
not used O.OOOE+00 R017 Ring 8
not used 0.O00E+00 ROl7 Ring 9
not used 0.O00E+00 R017 Ring 10 not used 0.000E+00 R017 Ring 11 not used O.000E+00 R017 Ring 12 not used O.O00E+00 R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 R018 other seafood consumption (kg/yr) 9.000-E01 9.000E-01 R018 soil ingestion rate (g/yr) 1.826E+01 3.650E+01 R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 R018 Contamination fraction of drinking water 1.O00E+00 1.O00E+O0 R018 Contamination fraction of household water not used 1.OOOE+00 R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 R018 Contamination fraction of aquatic food 1.OOOE+00 5.000E-01 R018 Contamination fraction of plant food 1.000E+00 '-1 IRESRAD, Version 6.5 Tx Limit = 30 days 11/28/2011 10:55 Page 7
Summary : HB soil DCGL_Pu-238 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILEs\\Pu238 DCGL\\HB SOIL DCGL_Pu238.RAD ed)
Used by RESRAD (If different from user input)
>0 shows circular AREA.
- A DCNUCCC 5)
DCNUCU( 5,1)
DCNUCS( 5)
ALEACHC 5)
SOLUBK(
5)
DCNUCCC 6)
DCNUCU( 6,1)
DCNUCSC 6)
ALEACHC 6)
SOLUBK( 6)
DCNUcc( 7)
DCNUCU( 7,1)
DCNUCSC 7)
ALEACHC 7)
SOLUBK( 7)
Parameter 3INHALR MLINH ED 3 SHF3 3 SHF1 FIND FOTD FS RADSHAPE(
1)
RADSHAPEC 2)
RADSHAPEC 3)
RADSHAPE(
4)
RADSHAPEC 5)
RADSHAPE(
6)
RAD_SHAPE( 7)
RADSHAPEC 8)
RADSHAPEC 9)
RADSHAPE(10)
RADSHAPE(11)
RADSHAPE(12) 3 FRACA( 1) 3 FRACA( 2)
FRACA( 3)
FRACA( 4)
FRACAC 5)
FRAcA( 6)
FRACAC 7)
FRACA( 8)
FRACA( 9)
FRACA(IO)
FRACA(ll)
FRAcA(12)
DIET(1)
DIET(2)
DIET(3)
DIET(4)
DIET(S)
DIET(6)
SOIL DWI FDW FHHW FLW FIRW FR9 FPLANT Parameter Name xSAAAAAAAAX~AAAW FMEAT FMILK 0
menu 3Parameter R018 Contamination fraction of meat R018 Contamination fraction of milk R019 Livestock fodder intake for meat (k R019 Livestock fodder intake for milk (k R019 Livestock water intake for meat (L/
R019 Livestock water intake for milk (L/
R019 Livestock soil intake (kg/day)
R019 Mass loading for foliar deposition R019 Depth of soil mixing layer (m)
R019 Depth of roots (m)i R019 Drinking water fraction from ground R019 Household water fraction from groun R019 Livestock water fraction from groun R019 Irrigation fraction from ground wal R198 wet weight crop yield for Non-Leaf)
R198 Wet weight crop yield for Leafy R19B 3 Wet weight crop yield for Fodder R198 Growing season for Non-Leafy (year R19B Growing season for Leafy (year R19B Growing season for Fodder (year R19B Translocation Factor for Non-Leaf R19B Translocation Factor for Leafy BtA RTLETT Site-Specific Parameter Summary (continued) user 3
3 used by RESRAD input.......
Defau.l.t......
di*f.erent rom user input) 1.O00E+00 '-1 1.000E+00 :-1 kg/day) 2.710E+01 6.800E+01 kg/day) 6.320E+01 5.500E801
'day) 5.060E+01 S.O000E+01
'day) 6.000E+01 1.600E+02 5.000E-01 5.000E-01 3 (g/m**3) 4.000E-04 1.000E-04 2.300E-01 1.500E-01 1.220E+00 9.000-01 d water 1.000E+00 1.000E+00 nd water not used 1.O000+0 nd water 1.000E+00 3 1.O000+0 ter 1.000E+00 1.000E+00 (kg/m**2) 1.750E+00 7.000E-01 (kg/m**2) 2.889E+00 1.500E+00 (kg/m**2) 1.887E+00 1.100E+00 2.460E-01 1.700E-01 rs) 1.230E-01 2.500E-01 rs) 8.200E-02 8.000E-02 y
1.O00E-01 1.O00E-01
,1 nh n
nnnn 1
MAEf00nn u*
3 3
3 3
3 3
3 3
3 3
LFI5 LFI6 LWI 5 LWI6 LSI MLFD DM DROOT FGwDW FGWHH FGWLW FGWIR YV(1 YV(2)
YV(3)
TE(1)
TE(2)
TE(3)
TIV(1)
TIV(2)
Page 106
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 R19B Translocation Factor for Fodder 1.000E+O0 1.OOOE+00 TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01
. RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 I 2.SOOE-01 RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy a 3.500E-01 a 2.500E-01
. RWET(1)
R19B wet Foliar Interception Fraction for Leafy I 5.800E-01 2.500E-01 I RWET(2)
R19B wet Foliar Interception Fraction for Fodder 3.SOOE-O1 I 2.500E-01 RWET(3)
R19B weathering Removal Constant for Vegetation 3.300E+01 2.OOOE+01 WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 C12CZ C14 Fraction of vegetation carbon from soil anot used 2.000E-02 CSOIL C14 Fraction of vegetation carbon from air not used a 9.800E-01 CAIR C14 a C-14 evasion layer thickness in soil (m) a not used a 3.000E-01 oMC C14 a C-14 evasion flux rate from soil (1/sec)
I not used 7.000E-07 EVSN C14 a C12 evasion flux rate from soil (3/sec) not used 1.000E-10 REVSN C14 a Fraction of grain in beef cattle feed a not used 8.OOOE-01 a AVFG4 C14 a Fraction of grain in milk cow feed a not used a 2.000E-01 a AVFG5 STOR Storage times of contaminated foodstuffs (days): a STOR Frults, non-leafy vegetables, and grain 1.400E+01 1.400E+01 a STORT(i)
STOR a Leafy vegetables 3 1.000E+00 a 1.000E+00 STORT(2)
STOR Milk a 1.000E+00 a 1.OOOE+00 STORT(3)
STOR Meat and poultry a 2.oooE+01 2.oOOE+01 STORT(4)
STOR a Fish 7.000E+00 7.000E+00 a STORT(5)
STOR a Crustacea and mollusks 7.000E+00 a 7.00OE+00 a STORT(6) 1RESRAD, Version 6.5 Ti` Limit = 30 days 11/28/2011 10:55 Page 8
Summary : HB soil DCGLPu-238 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\PU238 DCGL\\HB SOIL DCGLPU238.RAD site-Specific Parameter Summary (continued) 0 a
User a 3 used by RESRAD a
Parameter Menu aParameter Input.
Default a (if different from user input) a Name STOR well water ST1.0O0E+00 1.000E+00 a-a SiORT(7)
STOR Surface water I 1.000E+00 a 1.00OE+00 a-a STOR-T(8)
STOR Livestock fodder 3 4.500E+01 4.500E+01 a-a STOi T(9)
R021 Thickness of building foundation (m) a not used 1.500E-01 a-a FLOOR1 R021 Bulk density of building foundation (g/cm**3) a not used 2.400E+00 a-a DENSFL R021 Total porosity of the cover material a not used 4.000E-01 TPCV R021 Total porosity of the building foundation not used 1.000E-01 TPFL R021 volumetric water content of the cover material a not used 5.OOOE-02 a PH2OCV R021 volumetric water content of the foundation not used 3.OOOE-02
-P2OFL R021 Diffusion coefficient for radon gas (m/sec):
a R021 in cover material not used a 2.OOOE-06 DIFCV R021 in foundation material a not used 3.OOOE-07 a DIFFL R021 in contaminated zone soil a not used 2.000E-06 DIFCZ R021 Radon vertical dimension of mixing (m) a not used a 2.OOOE+00 a HMIX R021 Average building air exchange rate (1/hr) a not used a 5.00OE-01 REXG R021 Height of the building (room)
(m) a not used 2.500E+00 a~HRM R021 a Building interior area factor not used O.000E+00 a-a FAI R021 Building depth below ground surface (m) a not used a1 I 0Q00E+ 0 0 a-a DMFL R021 Emanating power of Rn-222 gas a not used a 2.500E-01 EMANA(1)
R021 Emanating power of Rn-220 gas a not used a 1.500E-01 EMANA(2)
TITL Number of graphical time points a
32 a
a.a.NPTS TITL Maximum number of integration points for dose 17 a..
LYMAX TITL Maximum number of integration points for risk a
a a
a KYMAX Summary of Pathway Selections
.o!ŽýY.
a User Selection external gamma active 2
inhalation (w/o radon)a active 3
plant ingestion active 4
meat ingestion active milk ingestion active 6
aquatic foods active 7-- drinking water active 8
soil ingestion active 9 --
radon suppressed Find peak pathway doses active ifitl/iffIf lt fiilffillffi111*ittii fltiffili1i1 1RESRAD, Version 6.5 Ti. Limit = 30 days 11/28/2011 10:55 Page 9
Summary : HB soil DCGLPU-238 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\Pu238 DCGL\\HB SOIL DCGLPU238.RAD Contaminated Zone Dimensions Initial Soil Concentrations..pci!g XXXXXKXXXXXIXXXXXAWAAXXXXXX SXXXXXXXA XXXXXXXXXXXXXAAAAAAAAAAAA Area:
30000.00 square meters Pu-238 1.000E+00 Thickness:
2.67 meters Cover Depth:
0.00 meters IRESRAD, Version 6.5 Ti Limit = 30 days 11/28/2011 10:55 Page
, 1 Probabilistic results summary : HB soil DCGL-PU-238 File : C:\\RESRAD-FAMILY\\RESRAD\\6.5\\USERFILES\\PU238 DCGL\\HB SOIL DCGL_Pu238.RAD Table of Contents Part VI: Uncertainty Analysis ORESRAD Uncertainty Analysis Results Probabilistic Input..
2 Total Dose...
..... 4 Total Risk...
5 Dose vs Pathway:
Ground External...................
6 Dose vs Pathway:
Inhalation (w/o Radon) 7 Dose vs Pathway:
Radon (Water Ind.)
8 Dose vs Pathway:
Plant (water Ind.)
9 Dose vs Pathway:
Meat (Water Ind.)
10 Dose vs Pathway:
Milk (water Ind.)
11 Dose vs Pathway:
Soil Ingestion.....................
12 Dose vs Pathway:
Water Ingestion....................
13 Dose vs Pathway:
Fish Ingestion....................
14 t'=BARTLETT Page 107
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Dose vs Pathway:
Radon (Water Dep.)................
s15 Dose vs Pathway:
Plant (Water Dep.).................
16 Dose vs Pathway:
Meat (water Dep.)
17 Dose vs Pathway:
Milk (water Dep.)
18 Cumulative Probability Summary....................
19 Summary of dose at graphical times, reptition 1..;
20 Peak of the mean dose at graphical times............
21 Correlation and Regression coefficients (if any)...
22 IRESRAD, Version 6.5 T" Limit = 30 days 11/28/2011 10:55 Page 2
Probabilistic results summary : HR soil DCGL-PU-238 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU238 DCGL\\HB SOIL DCGL.Pu238.RAD Probabilistic Input ONumber of sample Runs: 2000 Number Name Distribution Parameters 1
DENSCZ BOUNDED NORMAL 1.5635
.2385
.827 2.3 2
TPCZ BOUNDED NORMAL
.41
.09
.1319
.6881 3
HCCZ BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 4
BCZ BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 5
EVAPTR UNIFORM
.5
.75 6
RI UNIFORM
.36
.76 7
DENSAQ BOUNDED NORMAL 1.5105
.1855
.937 2.084 8
TPSZ BOUNDED NORMAL
.43
.0699
.214
.646 9
EPSZ BOUNDED NORMAL
.342
.0705
.124
.56 10 HCSZ BOUNDED LOGNORMAL-N.362 1.59
.0106 195 11 BSZ BOUNDED LOGNORMAL-N 1.96
.265 3.02 15.5 12 DWIBWT TRIANGULAR 6
10 30 13 UW UNIFORM 1173 1973 14 H(1)
UNIFORM 0
8.08 15 DENSUZ(1)
BOUNDED NORMAL 1.5635
.2385
.827 2.3 16 TPUZ(1)
BOUNDED NORMAL
.41
.09
.1319
.6881 17 EPUZ(1)
BOUNDED NORMAL
.315
.0905
.0349
.594 18 HCUZ(1)
BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 19 BUZ(1)
BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 20 MLINH CONTINUOUS LINEAR 8
0 0
.000008
.0151
.00003
.8119
.00004
.9495
.00006
.9937
.000076
.9983
.0001 1
21 SHF3 UNIFORM
.15
.95 22 SHF1 BOUNDED LOGNORMAL-N -1.3
.59
.044 1
23 DM TRIANGULAR 0
.15
.6 24 YV(1)
TRUNCATED LOGNORMAL-N
.56
.48
.001
.999 25 WLAM TRIANGULAR 5.1 18 84 26 RWET(2)
TRIANGULAR
.06
.67
.95 27 DCACTC(3)
TRUNCATED LOGNORMAL-N 6.86 1.89
.001
.999 28 DCACTUI(3)
TRUNCATED LOGNORMAL-N 6.86 1.89
.001
.999 29 DCACTS(3)
TRUNCATED LOGNORMAL-N 6.86 1.89
.001
.999 30 DCACTC(1)
TRUNCATED LOGNORMAL-N 7.78 2.76
.001
.999 31 DCACTUI(1)
TRUNCATED LOGNORMAL-N 7.78 2.76
.001
.999 32 DCACTS(1)
TRUNCATED LOGNORMAL-N 7.78 2.76
.001
.999 33 DCACTC(2)
TRUNCATED LOGNORMAL-N 5.2 1.68
.001
.999 34 DCACTU1(2)
TRUNCATED LOGNORMAL-N 5.2 1.68
.001
.999 35 DCACTS(2)
TRUNCATED LOGNORMAL-N 5.2 1.68
.001
.999 36 DCACTC(5)
TRUNCATED LOGNORMAL-N 8.17 1.7
.001
.999 37 OCACTUl(S)
TRUNCATED LOGNORMAL-N 8.17 1.7
.001
.999 38 DCACTS(5)
TRUNCATED LOGNORMAL-N 8.17 1.7
.001
.999 39 DCACTC(6)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001
.999 40 DCACTU1(6)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001
.999 41 DCACTS(6)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001
.999 42 DCACTC(7)
TRUNCATED LOGNORMAL 4.48 3.13
.001
.999 43 DCACTU1(7)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001
.999 44 DCACTS(7)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001
.999 45 BRTF(94,2)
TRUNCATED LOGNORMAL-N -9.21
.2
.001
.999 46 BRTF(94,3)
TRUNCATED LOGNORMAL-N -13.82
.5
.001
.999 47 BBIO(94,1)
LOGNORMAL-N 3.4 1.1 48 BRTF(82,1)
TRUNCATED LOGNORMAL-N -5.52
.9
.001
.999 1RESRAD 1 version 6.5 To Limit = 30 days 11/28/2011 10:55 Page 3
Probabilistic results summary : HR soil DCGL-PU-238 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILEs\\PU238 DCGL\\HB SOIL DCGLPU238.RAD Probabilistic Input (cont.)
Number Name Distribution Parameters AA49 BRTF82,2XTRNXAXDXLGNORXL-
-7.13 X.7 AX001 XX999 49 BRTF(82,2)
TRUNCATED LOGNORMAL-N -7.13
.7
.001
.999 50 RRTF(82,3)
TRUNCATED LOGNORMAL-N -8.11
.9
.001
.999 51 BBIO(82,1)
LOGNORMAL-N 5s7 1.1 52 BRTF(84,1)
TRUNCATED LOGNORMAL-N -6.9
.9
.001
.999 53 BRTF(84,2)
TRUNCATED LOGNORMAL-N -5.3
.7
.001
.999 54 BRTF(84,3)
TRUNCATED LOGNORMAL-N -7.82
.7
.001
.999 55 BBIO(84,1)
LOGNORMAL-N 4.6 1.1 56 BRTF(88,1)
TRUNCATED LOGNORMAL-N -3.22
.9
.001
.999 57 BRTF(88,2)
TRUNCATED LOGNORMAL-N -6.91
.7
.001
.999 58 BRTF(88,3)
TRUNCATED LOGNORMAL-N -6.91
.5
.001
.999 59 BBIO(88,1)
LOGNORMAL-N 3.9 1.1 60 BRTF(90,1)
TRUNCATED LOGNORMAL-N -6.91
.9
.001
.999 61 BRTF(90,2)
TRUNCATED LOGNORMAL-N -9.21 1
.001
.999 62 BRTF(90,3)
TRUNCATED LOGNORMAL-N -12.21
.9
.001
.999 63 BBIO(90,1)
LOGNORMAL-N 4.6 1.1 64 BRTF(92,1)
TRUNCATED LOGNORMAL-N -6.21
.9
.001
.999 65 BRTF(92,2)
TRUNCATED LOGNORMAL-N -7.13
.7
.001
.999 66 BRTF(92,3)
TRUNCATED LOGNORMAL-N -7.82
.6
.001
.999 67 RRIO(92,1)
LOGNORMAL-N 2.3 1.1 1RESRAD 1 version 6.5 To Limit = 30 days 11/28/2011 10:55 Page 21 Probabilistic results summary : HB soil DCGL-Pu-238 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU238 DCGL\\HB SOIL DCGLPU238.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1
O.OOOE+00 8.427E-01
.000016
.1365 t
BARTLETT Page 108
Bartlett Engineering Humboldt Bay Soil DCGLs Pu-239 Results:
ENG-HB-003 Rev. 0
- 1RESRAD, Version 6.5 T-Limit = 30 days 11/28/2011 11:45 Page 1
Summary : HB soil DCGLPu239 File
- C:\\RESRAD-FAMILY\\RESRAD\\6.S\\USERFILES\\PU239 DCGL\\HB SOIL DCGLPU239.RAD Table of Contents Part 1: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary...
2 site-Specific Parameter Summary..........................
4 Summary of Pathway Selections............................
8 Contaminated Zone and Total Dose Summary.................
9 Total Dose Components Time = O.OO E+O0....................................
10 Time = 1.0OOE+00.....................................
11 Time = 3.OOOE+00.
12 Time = 1.000E+01.....................................
13 Time = 3.OOOE+01......................................
14 Time = 1.000E+02......................................
15 Time = 3.000E+02......................................
16 Time = 1.000E+03..
17 Dose/Source Ratios Summed Over All Pathways..............
18 Single Radionuclide Soil Guidelines.......................
18 Dose Per Nuclide Summed Over All Pathways................
19 Soil Concentration Per Nuclide...........................
19 1RESRAD, version 6.5 T. Limit = 30 days 11/28/2011 11:45 Page 2
Summary : HB soil DCGLPu239 File
- C:\\RESBADFAMILY\\RESRAD\\6.5\\USERFILES\\PU239 DCGL\\HB SOIL DCGLPU239.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: HB DCGLs Plus FGR 12 & FGR 11 0
3 3 Current 3
Base Parameter Menu 3Parameter 3
value#
Case*
Name M *.'......
... v...'
e
.... a A-1 DCF'S for external ground radiation, (mrem/yr)/(pCi/g)
A-1 AC-227 (Source: FGR 12) 4.951E-04 4.951E-04 DCF1(
1)
A-1 Bi-211 (Source:
FGR 12) 2.559E-01 2.559E-01 DCF1(
2)
A-1 Fr-2 23 (Source: FGR 12) 1.980E-01 1.980E-01 DCF1(
3)
A-i Pa-231 (Source: FGR 12)
' 1.906E-01 1.906E-01 DCF1(
4)
A-1 Pb-211 (Source: FGR 12) 3.064E-01 3.064E-01 DCF1(
5)
A-1 Po-211 (Source:
FGR 12) 4.764E-02 4.764E-02 DCF1(
6)
A-i Po-215 (Source: FGR 12) 1.016E-03 1.016E-03 DCF1(
7)
A-1 Pu-239 (Source: FGR 12) 2.952E-04 2.952E-04 DCFI(
8)
A-1 Ra-223 (Source: FGR 12) 6.034E-01 6.034E-01 DCF1(
9)
A-1 Rn-219 (Source: FGR 12) 3.083E-01 3.083E-01 DCF1( 10)
A-1 Th-227 (Source:
FGR 12) 5.212E-01 5.212E-01I DCF1( 11)
A-1 Th-231 (Source:
FGR 12) 3.643E-02 3 3.643E-02 DCF1( 12)
A-1 TI-207 (Source: FGR 12) 1.980E-02 1.980E-02 DCF1( 13)
A-1 u-235 (Source: FGR 12) 7.211E-01 7.211E-01 DCF1( 14)
B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 AC-227+D
' 6.724E+00 6.700E+00 DCF2(
1)
B-1 Pa-231 1.280E+00 1.280E+00 DCF2(
2)
B-1 Pu-239 4.290E-01I 4.290E-01 DCF2(
3)
B-1 u-235+D 1.230E-01 1.230E-01 DCF2(
4)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-I AC-227+D 1.480E-02 1.410E-02 DCF3(
1)
D-1 Pa-231 1.060E-02 1.060E-02 DCF3(
2)
D-1 Pu-239 3.540E-03 3.540E-03 DCF3(
3)
D-1 U-235+O 2.673E-04 2.660E-04 DCF3(
4)
D-34 Food transfer factors:
D-34 AC-227+D
, plant/soil concentration ratio, dimensionless 2.500E-03 2.500E-03 RTF(
1,1)
D-34 AC-227+D beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 2.OOOE-0S 3 2.000E-05 RTF(
1,2)
D-34 AC-227+D milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.OOOE-0S 2.000E-05 ' RTF(
1,3)
D-34 D-34 Pa-231
, plant/soil concentration ratio, dimensionless 1.OOE-02 I 1.000E-02 3 RTF(
2,1)
D-34 Pa-231 beef/livestock-intake ratio, (pci/kg)/(pCi/d) 5.OOOE-03 5.000E-03 RTF(
2,2)
D-34 Pa-231 milk/livestock-intake ratio, (pci/L)/(pCi/d) 5.000E-06 5.000E-06 RTF(
2,3)
D-34 D-34 Pu-239
, plant/soil concentration ratio, dimensionless 1.830E-03 1.000E-03 RTF(
3,1)
D-34 Pu-239 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-04 1.000E-04 RTF(
3,2)
D-34 Pu-239 milk/livestock-intake ratio, (pCi/L) /(pci/d) 1.000E-06 1.OOOE-06 RTF(
3,3)
D-34 D-34 U-235+D
, plant/soil concentration ratio, dimensionless 3 2.500E-03 2.500E-03 RTF(
4,1)
D-34 3 U-235+D beef/livestock-intake ratio, (pci/kg)/(pci/d) 3.400E-04 3.400E-04 RTF(
4,2)
D-34 U-235S+D milk/livestock-intake ratio, (pCi/L)/(pCi/d) 6.000E-04 6.OOOE-04 RTF(
4,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 AC-227+D
, fish 1.500E+01 1.500E+01 BIOFAC(
1,1)
D-5 AC-227+D
, crustacea and mollusks 1.000E+03 1.000E+03 BIOFAC(
1,2)
D-5 1RESRAD, Version 6.5 T-Limit = 30 days 11/28/2011 11:45 Page 3
Summary : HB soil DCGL.Pu239 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\PU239 DCGL\\HB SOIL DCGLPu239.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)
Dose Library: MB DCGLs Plus FGR 12 & FGR 11 0
Current Base Parameter Menu 3Parameter 3
value#
3 Na e D-5 3 Pa-231
, fish 1.OOOE+01 ' 1.000E+01 BIOFAC(
2,1)
D-5 3 Pa-231
, crustacea and mollusks I.iOOE+02 1.100E+02 ' BIOFAC(
2,2)
D-5 3
D-5 3 Pu-239
, fish 3.000E+01 3.OOE+01I BIOFAC(
3,1)
D-5 3 Pu-239
, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC(
3,2)
D-5 3
D-5 3 U-235+D
, fish 1.000E+01 1.000E+01 BIOFAC(
4,1)
D-5 3 U-235+Do
.crustacea and mollusks 6.OOOE+01 6.000E+01 BIOFAC(
4 2)
- For OCFI(xxx) only, factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Default.Lib w/o Associate Nuclide contributions.
1RESRAD, Version 6.5 Ta Limit = 30 days 11/28/2011 11:45 Page 4
Summary : HB soil DCGLPu239
)BARTLETT Page 109
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 File
- C:\\RESRAD-FAMILY\\RESRAD\\6.5\\USERFILES\\PU239 DCGL\\HB SOIL DCGL_Pu239.RAD 0
Menu3 ROll ROll R011' ROll ROll ROll R011 R011 ROll ROll R011 R011 ROll R011 R011 R012 ROl2 R013 R012 R013 R013 ROl3 ROl)
ROl3 ROl3 R0l3 R013 R013 R013 R0l3 R013 ROl3 R013 R013 R013 R013 R014 R014 RO4 R014 R014 R013 ROI4 R013 ROl4 R014 RO14 Site-specific Parameter Summary User used by RESRAD Parameter
.Input l
lD aU lt lll f.l.lldi fre.ll rlu r ll pt)l
...... Name ParameterF.
k Area of contaminated zone (m**2)
Thickness of contaminated zone (m)
Fraction of contamination that is submerged Length parallel to aquifer flow (m)
Basic radiation dose limit (mrem/yr)
Time since placement of material (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Initial principal radionuclide (pCi/g):
Pu-239 Concentration in groundwater CpCi/L):
Pu-239 Cover depth (m)
Density of cover material (g/cm t 3)
Cover depth erosion rate (m/yr)
Density of contaminated zone (g/cm**3)
Contaminated zone erosion rate (m/yr)
Contaminated zone total porosity Contaminated zone field capacity Contaminated zone hydraulic conductivity (m/yr)
Contaminated zone b parameter Average annual wind speed (m/set)
Humidity in air (g/m*3)
Evapotranspiration coefficient Precipitation (m/yr)
Irrigation (m/yr)
Irrigation mode Runoff coefficient watershed area for nearby stream or pond (m**2)
Accuracy for water/soil computations Density of saturated zone (g/cm**3)
Saturated zone total porosity Saturated zone effective porosity Saturated zone field capacity Saturated zone hydraulic conductivity (m/yr)
Saturated zone hydraulic gradient Saturated zone b parameter water table drop rate (m/yr) well pump intake depth (m below water table)
Model: Nondispersion (ND) or Mass-Balance (MB) well pumping rate (m**3/yr)
Y3.00E+04 1.OO0E+04 2.670E+00 2.OOOE+00 O.OOOE+O0 O.OOE+00 1.950E+02 l.OO0E+02 2.500E+01 3.OOOE+01 O.O00OE+OO O.OOOE+O0 1.O00E+O0 1.OOOE+OO 3.OOOE+0O 3.0OOE+O0 1.OOOE+01 1.OOOE+01 3.OOOE+O1 3.OOOE+O1 1.OOOE+02 1.00E+02 3.OOOE+02 I 3.OOOE+02 l.OOOE+03 1.OO0E+O3 not used O.OOOE+OO not used O00OOE+O0 1.OOOE+O0 O.O00E+O0 not used O.OOOE+O0 O.OOOE+OO O.OOOE+O0 not used 1.500E+00 not used 1.O00E-03 1.564E+00 1.500E+00 2.200E-03 1.OOOE-03 4.100E-01 4.OOOE-01 9.50OE-02 2.OOOE-01 3.900E+00 1.OOOE+Ol 5.OOE+00 5.300E+00 3.040E+00 2.OOOE+O0 not used 8.000E+O0 6.250E-01 S.OOE-01 9.100E-01 1.000E+O0 5.600E-01 2.OOOE-O1 overhead overhead 5.OOOE-01 2.OOOE-01 2.520E+07 l.OOOE+06 1.OOE-03 1.OOOE-03 1.SlOE+O0 1.500E+O0 4.300E-01 4.OO0E-01 3.420E-01 2.OOOE-O1 8.800E-02 2.OOOE-O1 2.880E+01 1.OOOE+02 2.OOOE-03 2.OOOE-02 7.100E+O0 5.300E+00 1.000E-03 l.OOOE-03 l.OOOE+O1 1.OOOE+01 ND
'ND 1.573E+03I 2.500E+02 AREA 3 THICKO SUBMFRAcT LCZPAQ BRDL TI T( 2)
T(
3)
T( 4)
T(
5)
T( 6)
T(
7)
T(
8)
T( 9)
T(10) 3 S1(3) 3 wl( 3)
COVERO DENSCV VCV DENSCZ VCZ TPCZ FCCZ HCCZ BCZ WIND HUMID EVAPTR PRECIP RI IDITCH RUNOFF WAREA EPS DENSAQ TPSZ EPSZ FCSZ HCSZ HGWT BSZ VWT DWIBWT MODEL UW I_
iRESRAD, Version 6.5 T" Limit = 30 days 11/28/2011 11:45 Page 5
Summary : HB soil DCGL_Pu239 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\Pu239 DCGL\\HB SOIL DCGLPU239.RAD Site-Specii 0
1 menu Parameter R015 Number of unsaturated zone strata R01S Unsat. zone 1, thickness (m)
R015 Unsat. zone 1, soil density (g/cm**3)
R015 3Unsat. zone 1, total porosity RO15 Unsaat zone 1, effective porosity R015 Unsat. zone 1, field capacity RO15 Unsat. zone 1, soil-specific b parameter RO15 3Unsat. zone 1, hydraulic conductivity (m/yr)
R016 Distribution coefficients for Pu-239 R016 Contaminated zone (cm**3/g)
RO16 Unsaturated zone 1 (cm*
3/g)
R016 Saturated zone (cm**3/g)
R016 Leach rate C/yr)
R016 solubility constant R016 Distribution coefficients for daughter AC-227 R016 contaminated zone (cms*3/g)
RO16 unsaturated zone I (cm**3/g)
R016 Saturated zone (cmc*3/g)
RO16 Leach rate (/yr)
R016 solubility constant R016 Distribution coefficients for daughter Pa-231 R016 contaminated zone (cm*
3t
/g)
R016 unsaturated zone 1 (cm**3/g)
R016 Saturated zone (cm**3/g)
R016 Leach rate (/yr)
R016 solubility constant R016 Distribution coefficients for daughter U-235 R016 Contaminated zone (cm**3/g)
R016 unsaturated zone 1 (cm**3/g)
R016 Saturated zone (cm**3/g)
R016 Leach rate (/yr)
R016 Solubility constant R017 Inhalation rate (m**3/yr)
R017 Mass loading for inhalation (g/m**3)
ROl7 Exposure duration RO17 Shielding factor, inhalation R01o shielding factor, external gamma R017 Fraction of time spent indoors R017 Fraction of time spent outdoors (on site)
ROl7 Shape factor flag, external gamma IRESRAD, Version 6.5 T. Limit = 30 days Summary : HB soil DCGLPu239 t
BA RT L ETT fic Parameter Summary (continued)
User Inp.
Defaul..
Cif
'1
'1 4.040E+00 4.OOOE+O0 1.564E+00 1.500E+00 4.100E-01 4.OOOE-01 3.150E-01 2.OOOE-01 9.500E-02 2.OOOE-O1 5.600E+00 5.300E+00 3.900E+00 1.000E+Ol 9.530E+02 2.OOOE+03 9.530E+02 2.OOOE+03 9.530E+02 2.OOOE+03 O.O0OE+0O O.OOOE÷OO O.OOOE+00 O.OOOE+00 8.250E+02 2.OOOE+01 8.250E+02 2.OOOE+01 8.250E+02 2.OOOE+1O O.O0OE+0O O.OOOE+00 0.OOOE+OO O.OOOE+O0 3.800E+02 5.OOOE+01 3.800E+02 I S.OOOE+01 3.800E+02 5.OOOE+01 O.OOOE+OO O.OOOE+OO 0.OO0E+00 O.OOOE+0O 1.260E+02 5.OOOE+01 1.260E+02 5.OOOE+0O 1.260E+02 I 5.OOOE+01 O.OOOE+O0 O.OOOE+O0 O.OOOE+O0 O.OOOE+0O 8.400E+03 8.400E+03 1.000E-04 1.00OE-04 3.OOOE+01 3.OOOE+01 5.500E-01 4.OOOE-O1 2.725E-01 7.OOOE-01 6.571E-01 5.OOOE-O1 1.181E-01 2.500E-01 1.000E+O0 1.OOOE+OO 11/28/2011 11:45 Page 6
Used by RESRAD Parameter di erent from userinput)
Name XXAXSXX A A"XA4aAAAa AAAaAASSXAXXX&XXXXXXX 9.565E-05 not used 1.105E-04 not used 2.398E-04 not used 7,224E-04 not used
>0 shows circular AREA.
NS H(1)
DENSUZ(1)
TPUZ(I)
-EPUZ(1).
3FCUZ(1) 3BUZ(1)
HCUZ(1)
DCNUCC(
3)
DCNUCU( 3,1)
DCNUCS(
3)
ALEACH(
3)
SOLUBK(
3) 3 DCNUCC(
1)
DCNUCU( 1,1) 3 DCNUCS(
1) 3 ALEACH(
1)
SOLUBK(
1)
DCNUCC( 2)
DCNUCU( 2,1)
DCNUCS( 2) 3 ALEACH(
2)
SOLUBK(
2) 3DCNUCC( 4)
DCNUCU( 4,1) 3 DCNUCS(
4)
- ALEACH(
4)
SOLUBK( 4)
INHALR MLINH ED SHF3 SHF1 FIND FOTD FS Page 110
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 File C:\\RESRAD.FAMILY\\RESRAD\\6.5\\USERFILES\\PU239 DCGL\\HB SOIL DCGLPU239.RAD Site-Specific Parameter Summary (continued) 0 User 3
menu Para.meter input 3
Default (if R017 Radii of shape factor array (used if FS = -1):
R017 outer annular radius (m),
ring 1:
not used 5.000E+01 R017 Outer annular radius (m),
ring 2:
not used 7.071E+01 R017 3 outer annular radius (m),
ring 3:
not used 0.000E+00 RO17 outer annular radius (m),
ring 4:
not used O.000E+00 R017 3 outer annular radius (m),
ring 5:
not used 0.000E+00 R017 outer annular radius (m),
ring 6:
not used O.000E+00 R017 outer annular radius (m),
ring 7:
not used O.00OE+00 R017 outer annular radius (m),
ring 8:
not used 0.OOOE+00 R017 Outer annular radius (m),
ring 9:
not used O.00OE+00 R017 Outer annular radius (m),
ring 10:
3 not used O.00OE+00 R017 3 Outer annular radius (m),
ring 11:
not used O.000E+00 R017 Outer annular radius (m),
ring 12:
not used O.00OE+00 ROll Fractions of annular areas within AREA:
RO17 Ring 1
not used 1.OOOE+00 R017 Ring 2
not used 2.732E-01 R0l7 Ring 3
not used 0.000E+00 ROl7 Ring 4
not used 0.OOOE+00 R017 Ring 5
not used 0.OOOE÷00 R017 Ring 6
not used O.OOOEi00 R017 Ring 7
not used 0.0OOE+00 R017 Ring 8
not used 0.OOOE+00 R017 Ring 9
not used 0.000E+00 R017 Ring 10 not used 0.000E+00 R017 Ring 11 not used O.000E+00 R017 Ring 12 not used O.000E+00 R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 R018 other seafood consumption (kg/yr) 9.000E-01 9.OOOE-01 R018 Soil ingestion rate Cg/yr) 1.826E+01 3.650E+01 ROI8 Drinking water intake (L/yr) 4.785E+02 5.100E+02 R018 Contamination fraction of drinking water 1.000E+00 I.O00E+00 R018 Contamination fraction of household water not used 1.000E+00 R018 Contamination fraction of livestock water 1.000E+00 1.000E+O0 R018 Contamination fraction of irrigation water 1.000E+00 1.OO0E+00 R018 Contamination fraction of aquatic food 1.0OOE+00 5.000E-01 RO18 Contamination fraction of plant food 1.0OOE+00 3-1 R018 Contamination fraction of meat 1.000E+00 3-1 R018 Contamination fraction of milk 1.000E+00 :-1 ROI9 Livestock fodder intake for meat (kg/day) 2.710E+01 3 6.8001+01 RO9 Livestock fodder intake for milk (kg/day) 6.320E+01 3 5.500E+01 R019 Livestock water intake for meat (L/day) 5.060E+01 I 5.000E+01 R019 Livestock water intake for milk (L/day) 6.OOOE+01 1.600E+02 R019 Livestock soil intake (kg/day) 5.000E-01 I 5.000E-01 IRESRAD, version 6.5 T', Limit = 30 days 11/28/2011 11:45 Page 7
Summary : HB soil DCGLPu239 File
- C:\\RESRAD-FAMILY\\RESRAD\\6.5\\USERFILES\\PU239 DCGL\\HIB SOIL DCGL.PU239.RAD Site-Specific Parameter Summary (continued) 0 o user 3
Menu I Parameter 3.Input
- 3. Default (if R019 3 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 RO19 Depth of roots Im) 1.220E+00 9.000E-01 R019 Drinking water fraction from ground water 1000 1000+00 3 R019 Household water fraction from ground water not used 1.00OE+00 R019 Livestock water fraction from ground water 1.0006+0 I
0 100E+060 R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 R19B Wet weight crop yield for Fodder (kg/m**2) 1.8876+00 1.100E+00 R19B Growing season for Non-Leafy (years) 2.460E-01 1.700E-01I R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 R19B Growing season for Fodder (years) 8.200E-02 8.000E-02 R19B Translocation Factor for Non-Leafy 1.000E-01 1.00OE-01 R19B Translocation Factor for Leafy 1.000E+00 1.0006+00 Rl9B Translocation Factor for Fodder 1.000E+00 1.000E+00 R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 R19i wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 R19B wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 R19B wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 R19B weathering Removal Constant for Vegetation 3.300E+01 2.000E+01 C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 C14 Fraction of vegetation carbon from soil not used 2.0006-02 C14 Fraction of vegetation carbon from air not used 9.800E-01 C14 3 C-14 evasion layer thickness in soil (m) not used 3.000E-01 C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 C14 C-12 evasion flux rate from soil (1/sec) not used I.OOOE-10 C14 Fraction of grain in beef cattle feed not used 8.000E-01 C14 Fraction of grain in milk cow feed not used 2.OOOE-01 STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 STOR Leafy vegetables 1.000E+00 1.000E+00 STOR Milk 1.000E+00 1.000E+00 STOR Meat and poultry 2.000E+01 2.000E+01 STOR Fish 7.000E+00 7.OOOE+00 STOR Crustacea and mollusks 7.O00E+00 7.O00E+00 STOR Well water 1.OOOE+00 1.000E+00 SIOR Surface water 1.000E+00 I1.O00E+O STOR Livestock fodder 4.500E+01 4.500E+01 R021 Thickness of huildin fnondation (m) nnt used I 1500E-0li used by RESRAD Parameter differ In from user input) ame
-RAD_SHAPE( 1)
-RAD.SHAPE(
2)
RAD-SHAPE(
3)
RADSHAPE( 4)
-RAD..SHAPE(
5) 3 RADSHAPE( 6) 3 RADSHAPE(
7)
RAD.SHAPE( 8) 3 RADSHAPE(
9)
RADSHAPE(10)
RADSHAPE(11) 3 RADSHAPE(12)
-- FRACA( 1)
-- FRACA( 2)
-- FRACAC 3)
-- FRACA( 4)
-- FRACAC 5)
FRACAC 6)
-FRACA(7) 3 FRACAC 8) 3 FRACA( 9)
-- FRACA(10) 3 FRACA(11)
FRACA(12)
DIET(1)
DIET(2) 3 DIET(3)
DIET(4)
DIET(S) 3 DIET(6)
-SOIL
-- DWI
-- FDW
-- FHHW
-- FLW
-- FIRW
-- FR9 FPLANT FMEAT FMILK
-- LFIS LFI6
-- LWIS LWI6
- -LSI Used by RESRAD different from user XXXX
_x X
XXX Parameter input)
Name MLFD DM DROOT FGWDW FGW`HH FGWLW FGWIR YV(1)
YV(2)
Yv(3)
TEMI
-E(2)
TE(3)
TIV(1) 1IV(2)
TIV(3) 3 RDRY(1) 3 RDRY(2)
RDRY(3)
RWET(1)
RWET(2)
' RWET(3) 3 WLAI C12WTR Ci2CZ CSOIL CAIR DMC 3 EVSN 3 REVSN 3 AVFG4 AVFG5 STORT(1)
STOPOTL(2)
STOPT(3)
STORT(4)
STIOLT(S)
STORT(6)
STORT(7) 3 STOI T(8)
STORT(S)
FI r"inoRi t BARTLETT Page 111
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 R021 3 Bulk density of building foundation (g/cm**3) 3 not used I 2.400E+00 DENSFL R021 3 Total porosity of the cover material 3 not used I 4.OOOE-01 3 TPCV R021 3 Total porosity of the building foundation 3 not used 3 1.00OE-01 3 3 TPFL
- 1RESRAD, Version 6.5 T' Limit = 30 days 11/28/2011 11:45 Page 8
summary : HB soil DCGLPu239 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU239 DCGL\\HB SOIL DCGL_Pu239.RAD site-Specific Parameter Summary (continued) 0 Preruser used by RESRAD 3
Parameter MeuPrmtrinput Default (if different from user input)
Name AA R021 Volumetric water content of the cover naterial not used 5.OOOE-02 PH2OCV R021 volumetric water content of the foundation not used 3.OOOE-02 PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 3 2.OOOE-06 DIFCV R021 in foundation material not used 3.OOOE-07 DIFFL R021 in contaminated zone soil not used 2.OOOE-06 DIFCZ R021 Radon'vertical dimension of mixing (m) not used 2.OOOE+00 HMIX R021 Average building-air exchange rate (1/hr) not used I 5.000E-01 REXG R021 Height of the building (room)
(m) not used I 2.500E+00 HRM R021 Building interior area factor not used 30.OOOE+00 FAI R021 Building depth below ground surface (m) not used 1-1.000E+00 DMFL R021 Emanating power of Rn-222 gas not used 3 2.500E-01 EMANA(1)
R021 Emanating power of Rn-220 gas not used 3 1.500E-01 EMANA(2)
TITL Number of graphical time points 32 NPTS TITL Maximum number of integration points for dose 17 3
LYMAX TITL Maximum number of integration points for risk 1
KYMAX Summary of Pathway selections use.r select..n 1-- external gamma 3
active 2
inhalation (w/o radon) 3 active 3 -- plant ingestion active 4-- meat ingestion active 5 milk ingestion active 6
aquatic foods active 7--
drinking water active 8
soil ingestion active 9 --
radon suppressed Find peak pathway doses active fflitfftf tff ftttttttfttttfttttttfiiflttififtit~t iRESRAD, Version 6.5 T. Limit = 30 days 11/28/2011 11:45 Page 9
Summary : HB soil DcGL_.Pu239 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\Pu239 DCGL\\HB SOIL DCGLPu239.RAD Contaminated Zone Dimensions Initial Soil.Concentrations.pci/g a~xxXX~sxX~sX5XsXX5XxXAxAAAAAXAXXXXX AXXXSAXAXAAAAAAAAAAAA Area:
30000.00 square meters Pu-239 1.O0OE+00 Thickness:
2.67 meters Cover Depth:
0.00 meters 1RESRAD* Version 6.5 Tm Limit = 30 days 11/28/2011 11:45 Page 1
Probabilistic results summary : HR soil DCGLPu239 File : C:\\RESRAD.FAMILY\\RESRAD\\6.5\\USERFILES\\Pu239 DCGL\\HB SOIL DCGLPU239.RAD Table of Contents AAA4vAAAxAxAws Part VI: Uncertainty Analysis tIfttifflttiffiftttttilffl1 ORESRAD Uncertainty Analysis Results Probabilistic Input..
2 Total Dose...
4 Total Risk...
5 Dose vs Pathway:
Ground External...................
6 Dose vs Pathway:
Inhalation (w/o Radon) 7 Dose vs Pathway:
Radon (water Ind.)................
8 Dose vs Pathway:
Plant (water Ind.).................
9 Dose vs Pathway:
Meat (water Ind.)................
10 Dose vs Pathway:
Milk (Water Ind.)................
11 Dose vs Pathway:
soil Ingestion....................
12 Dose vs Pathway:
Water Ingestion....................
13 Dose vs Pathway:
Fish Ingestion....................
14 Dose vs Pathway:
Radon (water Dep.)................
15 Dose vs Pathway:
Plant (Water Dep.)................
16 Dose vs Pathway:
Meat (water Dep.)................
17 Dose vs Pathway:
Milk (water Dep.)................
18 Cumulative Probability summary.......................
19 Summary of dose at graphical times, reptition 1.....
20 Peak of the mean dose at graphical times.............
21 Correlation and Regression coefficients (if any).....
22 IRESRAD, version 6.5 T<< Limit = 30 days 11/28/2011 11:45 Page 2
Probabilistic results summary : HB soil DCGLPU239 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILEs\\Pu239 DCGL\\HB SOIL DCGLPu239.RAD Probabilistic Input ONumber of Sample Runs: 2000 Number Name Distribution Parameters 1
DENSCZ BOUNDED NORMAL 1.5635
.2385
.827 2.3 2
TPCZ BOUNDED NORMAL
.41
.09
.1319
.6881 3
HCCZ BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 4
BCZ BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 5
EVAPTR UNIFORM
.5
.75 6
RI UNIFORM
.36
.76 7
DENSAQ BOUNDED NORMAL 1.5105
.1855
.937 2.084 8
TPSZ BOUNDED NORMAL
.43
.0699
.214
.646 9
EPSZ BOUNDED NORMAL
.342
.0705
.124
.56 10 HCSZ BOUNDED LOGNORMAL-N.362 1.59
.0106 195 11 BSZ BOUNDED LOGNORMAL-N 1.96
.265 3.02 15.5 12 DWIBWT TRIANGULAR 6
10 30 13 UW UNIFORM 1173 1973 14 H(1)
UNIFORM 0
8.08 15 DENSUZ(1)
BOUNDED NORMAL 1.563S
.2385
.827 2.3 t) BARTLETT Page 112
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 16 TPUZ(1)
BOUNDED NORMAL
.41
.09
.1319 17 EPUZ(1)
BOUNDED NORMAL
.315
.0905
.0349 18 HCUZ(1)
BOUNDED LOGNORMAL-N 1.36 2.17
.00478 19 BUZ(1)
BOUNDED LOGNORMAL-N 1.73
.323 2.08 20 MLINH CONTINUOUS LINEAR 8
0 0
.00003
.8119
.00004
.9495
.00006
.9937
.000076
.9983
.0001 21 SHF3 UNIFORM
.15
.95 22 SHF1 BOUNDED LOGNORMAL-N -1.3
.59
.044 23 DM TRIANGULAR 0
.15
.6 24 YV(1)
TRUNCATED LOGNORMAL-N.56
.48
.001 25 WLAM TRIANGULAR 5.1 18 84 26 RWET(2)
TRIANGULAR
.06
.67
.95 27 DCACTC(3)
TRUNCATED LOGNORMAL-N 6.86 1.89
.001 28 DCACTU1(3)
TRUNCATED LOGNORMAL-N 6.86 1.89
.001 29 DCACTS(3)
TRUNCATED LOGNORMAL-N 6.86 1.89
.001 30 DCACTC(1)
TRUNCATED LOGNORMAL-N 6.72 3.22
.001 31 DCACTUI(1)
TRUNCATED LOGNORMAL-N 6.72 3.22
.001 32 DCACTS(1)
TRUNCATED LOGNORMAL-N 6.72 3.22
.001 33 DCACTC(2)
TRUNCATED LOGNORMAL-N 5.94 3.22
.001 34 DCACTU1(2)
TRUNCATED LOGNORMAL-N 5.94 3.22
.001 35 DCACTS(2)
TRUNCATED LOGNORMAL-N 5.94 3.22
.001 36 DCACTC(4)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001 37 DCACTUI(4)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001 38 DCACTS(4)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001 39 BRTF(94,2)
TRUNCATED LOGNORMAL-N -9.21
.2
.001 40 BRTF(94,3)
TRUNCATED LOGNORMAL-N -13.82
.5
.001 41 BBIO(94,1)
LOGNORMAL-N 3.4 1.1 42 BRTF(89,1)
TRUNCATED LOGNORMAL-N -6.91 1.12
.001 43 BRTF(89,2)
TRUNCATED LOGNORMAL-N -10.82 1
.001 44 BRTF(89,3)
TRUNCATED LOGNORMAL-N -13.12
.9
.001 45 BBIO(89,1)
LOGNORMAL-N 2.7 1.1 46 BRTF(91,1)
TRUNCATED LOGNORMAL-N -4.61 1.1
.001 47 BRTF(91,2)
TRUNCATED LOGNORMAL-N -12.21 1
.001 48 BRTF(91,3)
TRUNCATED LOGNORMAL-N -12.21
.9
.001 1RESRAD, Version 6.5 T", Limit = 30 days 11/28/2011 11:45 Page 3
Probabilistic results summsary : HB soil DCGL.Pu239 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU239 DCGL\\HB SOIL DCGL.PU239.RAD Probabilistic Input (cont.)
.6881
.594 3190 15.3
.000008 1
1
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.0151
.000016
.1365 Number 49 50 51 52 53
'tffit Name BBIO(91,1)
BRTF(92,1)
BRTF(92,2)
BRTF(92,3)
BBIO(92,1)ffftfi ttII1111 fill ttf t Distribution Parameters LOGNORMAL-N 2.3 1.1 TRUNCATED LOGNORMAL-N -6.21
.9
.001
.999 TRUNCATED LOGNORMAL-N -7.13
.7
.001
.999 TRUNCATED LOGNORMAL-N -7.82
.6
.001
.999 LOGNORMAL-N 2.3 1.1 1RESRAD, version 6.5 T71 Limit = 30 days 11/28/2011 11:45 Page 21 Probabilistic results summary : HB soil DCGL.Pu239 File : C:\\RESRADPFAMILY\\RESRAD\\6.5\\USERFILES\\PU239 DCGL\\HB SOIL DCGLPU239.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1
0.OOOE+00 9.358E-01
(#0BARTLETT Page 113
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 Pu-240 Results:
1RESRAD,'version 6.5 T< Limit = 30 days 11/28/2011 11:51 Page 1
Summary': HB soil DCGLOPu240 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU240 DCGL\\HB SOIL DCGLPU240.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines t111ttiifffffififf ttfit*ifffffiftffttffftfftifttfftt Dose Conversion Factor (and Related) Parameter Summary...
2 Site-Specific Parameter Summary............................
4 Summary of Pathway Selections..............................
8 Contaminated zone and Total Dose Summary.................
9 Total Dose Components Time = 0.O00E+O0.......................................
10 Time = 1.0OOE+0 11 Time = 3.OOOE+00.....................................
12 Time = 1.000E+01.....................................
13 Time = 3.OOOE+01.....................................
14 Time = i.000E+02..
15 Time = 3.OOOE+02....................................
16 Time = I.O00E+03....................................
17 Dose/Source Ratios Summed Over All Pathways..............
18 Single Radionuclide Soil Guidelines.......................
18 Dose Per Nuclide Summed Over All Pathways.................
19 Soil Concentration Per Nuclide...........................
19 iRESRAD, Version 6.5 Ta Limit = 30 days 11/28/2011 11:51 Page 2
Summary : HB soil DCGLPu240 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\PU240 DCGL\\HB SOIL DCGLPU240.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: HB DCGLs Plus FGR 12 & FGR 11 0
Current R
Base Parameter menu 3Parameter 3
value#
I Case*
Name A-1 DCF'S for external ground radiation, (mrem/yr)/(pCi/g)
A-1I AC-228 (Source:
FGR 12) 5.978E+00 5.978E+00 DCFI(
1)
A-1 I Bi-212 (Source:
FGR 12) 1.171E+00 I1.171E+00 DCFI(
2)
A-1 Pb-212 (Source:
FGR 12) 7.043E-01 7.043E-01 I DCF1(
3)
A-1 I Po-212 (Source:
FGR 12)
O.OOE+00 0.O0E+OO DCF1(
4)
A-1I Po-216 (Source:
FGR 12) 1.042E-04 1.042E-04 DCFI(
5)
A-1I Pu-240 (Source: FGR 12) 1.467E-04 1.467E-04 DCFi(
6)
A-1 Ra-224 (Source: FGR 12) 5.119E-02 5.119E-02 DCFi(
7)
A-1 Ra-228 (Source: FGR 12) 0.OOOE+00 O.OOOE+00 DCFi(
8)
A-1 Rn-220 (Source:
FGR 12) 2.298E-03 2.298E-03 DCFi(
9)
A-1 Th-228 (Source: FGR 12) 7.940E-03 7.940E-03 DCF1( 10)
A-1 Th-232 (Source:
FGR 12) 5.212E-04 5.212E-04 DCF1( 11)
A-1 Tl-208 (Source:
FGR 12) 2.298E+01 2.298E+01 DCFI(
12)
A-1 u-236 (Source:
FGR 12) 2.148E-04 2.148E-04 DCFI(
13)
B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Pu-240 4.290E-01 4.290E-01 DCF2(
1)
B-1 Ra-228+D 5.078E-03 4.770E-03 DCF2(
3)
B-1 Th-228+D 3 454E-01 3 3.420E-01 3 DCF2(
4)
B-1 Th-232 1.640E+00 I 1.640E+00 3 DCF2(
5)
B-1 u-236 1.250E-01 : 1.250E-01 : DCF2(
6)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Pu-240 3.540E-03 3.540E-03 DCF3(
1)
D-1 Ra-228+D 1.442E-03 1.440E-03 DCF3(
3)
D-1 Th-228+D 8.086E-04 3.960E-04 DCF3(
4)
D-1 Th-232 2.730E-03 2.730E-03 DCF3(
5)
D-1 u-236 2.690E-04 2.690E-04 DCF3(
6)
D-34 Food transfer factors:
D-34 Pu-240
, plant/soil concentration ratio, dimensionless 1.830E-03 1.000E-03 RTF(
1,1)
D-34 I Pu-240 beef/livestock-intake ratio, (pCi/kg)/(pci/d) 1.000E-04 1.OOOE-04 RTF(
1,2)
D-34 Pu-240 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.OOOE-06 ' 1.OOOE-06 RTF(
1,3)
D-34 D-34 3 Ra-228+D
, plant/soil concentration ratio, dimensionless 4.OOOE-02 4.OOOE-02 RTF(
3,1)
D-34 Ra-228+D
, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1 OOOE-03 3 1.OOOE-03 RTF(
3,2)
D-34 Ra-228+D
, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.OOOE-03 1.000E-03 RTF(
3,3)
D-34 D-34 Th-228+D
, plant/soil concentration ratio, dimensionless 1.OOOE-03 1.OOOE-03 RTF(
4,1)
D-34 I Th-228+D
, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.OOOE-04 I1.OOOE-04 RTF(
4,2)
D-34 I Th-228+D
, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 5.OOOE-06 5.OOOE-06 RTF(
4,3)
D-34 3 D-34 Th-232
, plant/soil concentration ratio, dimensionless 1.OOOE-03 1.OOOE-03 RTF(
5,1)
D-34 Th-232 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.OOOE-04 I.000E-04 RTF(
5,2)
D-34 Th-232 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 5.OOOE-06 5.OOOE-06 RTF(
5,3)
D-34 D-34 U-236
, plant/soil concentration ratio, dimensionless 2.500E-03 2.500E-03 RTF(
6,1)
D-34 U-236 beef/livestock-intake ratio, (pCi/kg)/(pci/d) 3.400E-04 3.400E-04 RTF(
6,2)
D-34 U-236 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 6.OOOE-04 6.OOOE-04 RTF(
6,3)
- 1RESRAD, Version 6.5 To Limit = 30 days 11/28/2011 11:51 Page 3
Summary : HB soil DCGL_Pu240 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU240 DCGL\\HB SOIL DCGLPU240.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)
Dose Library: HB DCGLS Plus FGR 12 & FGR 11 0
Current Base Parameter Menu 3Parameter 3
value#
3 Case*a Name D-5 3 Bioaccumulation factors, fresh water, L/kg:
D-5 I Pu-240
, fish 3.000E+01 3.OOOE+01 BIOFAC(
1,1)
D-5 Pu-240
, crustacea and mollusks 1.OOOE+02 1.OOOE+02 BIOFAC(
1,2)
D-5 D-5 Ra-228+D
, fish 5.OOOE+01 5.OOOE+Oi BIOFAC(
3,1)
D-5 Ra-228+D
, crustacea and mollusks 2.500SE+02 2.500E+02 BIOFAC(
3,2)
D-S D-S Th-228+D
, fish 1.OOOE+02 1.000E+02 BIOFAC(
4,1)
D-5 Th-228+D
, crustacea and mollusks 5.OOOE+02 5.000E+02 BIOFAC(
4,2)
D-5 D-5 Th-232
, fish 1.OOOE+02 1.00+02 BIOFAC(
5,1)
D-S Th-232
, crustacea and mollusks 5.OOOE+02 5.000E+02 BIOFAC(
5,2) t BARTLETT Page 114
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 D-5 D-5
- u-236
, fish 1.OOOE++1 31.0OE+01 BIOFAC(
6,1)
D-5 3 u-236 crustacea and mollusks 6.OOOE+01 6.00OE+01 BIOFAC(
6 2)
- 1tt1**1fttlf tittt 1tt~t~~1tttt t11**tttltttilfilflffffiiftltiffiltiltffilfttlittffffillltttitI
- For DCFI(xxx) only factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Delault.Lib W/o Associate Nuclide contributions.
- 1RESRAD, Version 6.5 T" Limit = 30 days 11/28/2011 11:51 Page 4
Summary : HB soil DCGL--Pu240 File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU240 DCGL\\HB SOIL DCGL_PU240.RAD 0
3 menu Parameter Roll 3 Area of contaminated zone (m**2)
ROll Thickness of contaminated zone (m)
R011 Fraction of contamination that is submer R011 Length parallel to aquifer flow (m)
R011 Basic radiation dose limit (mrem/yr)
R011 Time since placement of material Cyr)
R011 Times for calculations Cyr)
R011 Times for calculations Cyr)
ROll Times for calculations Cyr)
R011 Times for calculations Cyr)
R011 Times for calculations Cyr)
ROll Times for calculations Cyr)
RO11 Times for calculations Cyr)
ROll Times for calculations Cyr)
R011 Times for calculations Cyr)
R012 Initial principal radionuclide (pCi/g):
R012 Concentration in groundwater (pCi/L):
R013 Cover depth (m)
R013 Density of cover material (g/cm**3)
R013 Cover depth erosion rate (m/yr)
R013 Density of contaminated zone (g/cm**3)
R013 Contaminated zone erosion rate (m/yr)
ROl3 Contaminated zone total porosity R013 Contaminated zone field capacity R013 Contaminated zone hydraulic conductivity RO13 Contaminated zone b parameter R013 Average annual wind speed (m/sec)
R013 Humidity in air (g/m**3)
R013 Evapotranspiration coefficient R013 Precipitation (m/yr)
R013 Irrigation (m/yr)
R013 Irrigation mode R013 Runoff coefficient R013 Watershed area for nearby stream or pond R013 Accuracy for water/soil computations R014 Density of saturated zone (g/cm**3)
R014 Saturated zone total porosity R014 Saturated zone effective porosity R014 Saturated zone field capacity R014 Saturated zone hydraulic conductivity (m R014 Saturated zone hydraulic gradient R014 Saturated zone b parameter R014 Water table drop rate (m/yr)
RO14 Well pump intake depth (m below water ta RO14 Model: Nondispersion (ND) or Mass-Balanc R014 well pumping rate (m**3/yr)
Site-Specific Parameter Summary User 3
used by RESRAD Parameter Input
'.Default (if different from user inpu.t) 3 Name 3.OOOE+04 1.OOOE+04 AREA 2.670E+00 2.000E+00 THICKO ged 0.OOOE+00 O.OOOE+00 SUBMFRACT 1.950E+02 1.OOOE+02 LCZPAQ 2.500E+01 3.OOOE+O1 BRDL 0.000E+00 O.OOOE+00 TI I.OOOE+00 I.OOOE+00 T( 2) 3.OOOE+00 3.00OE+O0 T( 3) 1.000E+01 3 1.000E+01 T(
4) 3.00OE+O1 3.OOOE+O1 T5) 1.OOOE+02 1.000E+02 3 3 T(
6) 3.000E+02 3.000E+02 T( 7) 1.OOOE+03 1.OOOE+03 T( 8) not used 0.OOOE+O0 T( 9) not used 0.000E+00 TC10)
Pu-240 l.OOOE+00 0.OOOE+00 SI(1)
Pu-240 3 not used 0.000E+O0 wl(
1) 0.OOOE+00 O.OOOE+0O COVERO not used 1.SO0E+00 DENSCV not used 1.000E-03 VCV 1.564E+00 3 1.500E+00 DENSCZ 2.200E-03 1.000E-03 vCZ 4.1OOE-01 4.000E-01 TPCZ 9.500E-02 2.OOOE-01 3 FCCZ (m/yr) 3.900E+00 I.OOOE+OI HCCZ 5.600E+00 5.300E+00 BCZ 3.040E+00 2.000E+00 WIND not used 8.OOOE+00 HUMID 6.250E-01 5.0S E-O01 EVAPTR 9.1OOE-O1 1.000E+00 PRECIP 5.600E-01 2.OOOE-01 RI overhead overhead IDITCH 5.OOOE-Ol 2.OOOE-Ol RUNOFF (m'2) 2.520E+07 I.OOOE+06 WAREA 1.000E-03 1.OOOE-03 EPS 1.510E+00 1.500E+00 DENSAQ 4.300E-01 4.OOOE-O1 TPSZ 3.420E-01 2.OOOE-01 EPSZ 8.800E-02 2.OOOE-O1 FCSZ
/yr) 2.880E+01 1.OOOE+02 HCSZ 3 2.000E-03 2.OOOE-02 HGWT 7.1OOE+OO 5.300E+00 BSZ 1.00OE-03 I.OOOE-03
,,T ble) l.OOOE+OI 1.OOOE+00 DWIBWT e (MB)
ND ND MODEL I 1.573E+03 2.500E+02
' UW uAA IRESRAD, version 6.5 Tav Limit = 30 days 11/28/2011 11:51 Page 5
Summary : H soil DCGLPu240 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU240 DCGL\\HB SOIL DCGLPU240.RAD 0
3 Men U Site-Specific Parameter Summary (continued)
User 3
used by RESRAD Parameter
,,
- 9,,,
,.[,,?
2 D
Parameter AAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAA R015 Number of unsaturated zone strata R1S Unsat. zone 1, thickness (m)
R015 I Unsat. zone 1, soil density (g/cm**3)
R015 Unsat. zone 1, total porosity ROS Unsat. zone 1, effective porosity R015 3 Unsat. zone 1, field capacity ROlS 3 Unsat. zone 1, soil-specific b parameter RO1S Unsat. zone 1, hydraulic conductivity (m/yr)
R016 Distribution coefficients for Pu-240 RO16 Contaminated zone (cm**3/g)
R016 Unsaturated zone 1 (cm**3/g)
R016 Saturated zone (cm.*3/g)
R016 Leach rate (/yr)
R016 solubility constant R016 Distribution coefficients for daughter Ra-228 R016 Contaminated zone (cm**3/g)
R016 3 Unsaturated zone 1 (cm**3/g)
R016 Saturated zone (cm**3/g)
R016 Leach rate (/yr)
R016 3 Solubility constant R016 Distribution coefficients for daughter Th-228 R016 Contaminated zone (cm**3/g)
R016 unsaturated zone 1 (cm**3/g)
R016 3 Saturated zone (cm**3/g)
R016 Leach rate (/yr)
R016 Solubility constant R016 Distribution coefficients for daughter Th-232 R016 Contaminated zone (cm**3/g)
R016 unsaturated zone 1 (cm**3/g)
R016 Saturated zone (cm**3/g)
R016 Leach rate (/yr)
R016 3 Solubility constant R016 ' Distribution coefficients for daughter U-236 R016 3 Contaminated zone (cmc*3/g)
QBARTLETT 31
.1 4.040E+00 4.OOOE+00 1.564E+00 1.500E+00 4.100E-01 4.OOOE-Ol 3.150E-01 2.OOOE-01 9.500E-02 2.OOOE-01 5.600E+00 5.300E+00 3.900E+00 1.OOOE+01 9.530E+02 2.OOOE+03 9.530E+02 2.000E+03 9.530E+02 2.000E+03 O.O000E+00 O.OOOE+00 30
.0008+00 0.000E+00 3.533E+03 7.000E+01 I 3.533E+03 3 7.OOOE+01 3.533E+03 7.0OOE+Ol 0.OOOE+00 0.000E+00 0.OOOE+03 0.00O8+00 5.884E+03 6.OOOE+04 5.884E+03 6.0OOE+04 5.884E+03 6.OO0E+04 0.000E+0 0.000E+00 0.000E+00 3 0.00OE+00 5.884E+03 6.00OE+04 5.884E+03 6.000E+04 5.884E+03 6.000E+04 0.000E+0 0.00OE+00 0.OO0E+00 0.O00E+00 1.260E+02 5.0O0E+O1 9.565E-05 not used 2.581E-05 not used 1.550E-05 not used 1.550E-05 not used NS SH(1)
DENSUZ(1)
TPUZ(1)
EPUZ(1)
FCUZ(1)
BUZ(l)
HCUZ(1)
DCNUCC( 1)
DCNUCU( 1,1)
DCNUCS( 1)
ALEACH( 1)
SOLUBK(
1)
DCNUCC( 3)
DCNUCU( 3,1)
DCNUCS(
3)
ALEACH( 3)
SOLUBK( 3)
DCNUCC( 4)
DCNUCU( 4,1)
DCNUCS( 4)
ALEACH( 4)
SOLUBK( 4)
DCNUCC( 5)
DCNUCU( 5,1)
='DCNUCS( S) 3 ALEACH( 5) 3 SOLUBK( 5)
' DCNUCC( 6)
Page 115
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R016 unsaturated zone 1 (cm**3/g) 1.260E+02 5.OO0E+01 DCNUCU( 6,1)
R016 Saturated zone (cm**3/g) 1.260E+02 a 5.OOOE+01 a DCNUCS( 6)
R016 Leach rate (/yr) 0.O00E+00 a 0.000E+00 7.224E-04 a ALEACH( 6)
R016 Solubility constant a 0.000E+00 a 0.000E+00 not used a SOLUBK( 6) 3 a a
aa R017 Inhalation rate (m**3/yr) 8.400E+03 a 8.400E+03 a---
INHALR R017 Mass loading for inhalation (g/m**3) a1.000E-04 1.O000E-04 a MLINH R017 Exposure duration 3.000E+01 a 3.000E+01 a ED R017 Shielding factor, inhalation 5.500E-01 a 4.OOOE-01 aa SHF3 RO17 Shielding factor, external gamma 2.725E-01 a 7.000E-01 aa SHF1 RO17 Fraction of time spent indoors 6.571E-01 5.0006E-01 aFIND 1RESRAD, Version 6.5 T. Limit ý 30 days 11/28/2011 11:51 Page 6
Summary : HB soil DCGL_Pu240 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU240 DCGL\\HB SOIL DCGLPU240.RAD Site-Specific Parameter Summary (continued) 0 a3 User 3
a used by RESRAD a
Parameter menu aParameter a
Input a
Default a (If different from user input) a Name R017 Fraction of time spent outdoors (on site) a 1.181E-01 a 2.S00E-01 a FOTD R017 a Shape factor flag, external gamma a 1.0006E+00 1.000E+00 a
>0 shows circular AREA.
FS R017 a Radii of shape factor array (used if FS = -1):
3 a
R017 Outer annular radius (i),
ring 1:
not used 5.000E+01 RADSHAPE(1)
R017 Outer annular radius (m),
ring 2:
not used a7.0716+01 aRAD.SHAPE(
2)
R017 a Outer annular radius (m),
ring 3:
not used a 0.0006E+0 RAD.SHAPE(
3)
R017 a Outer annular radius (m),
ring 4:
a not used a 0.00E+00 a a BAD-SHAPE(
4)
R017 a
Outer annular radius (m),
ring 5:
not used a O.000E+00 a a RADSHAPE(
5)
R017 a Outer annular radius (m),
ring 6:
a not used a 0.00E+00 RADSHAPE( 6)
R017 Outer annular radius (m),
ring 7:
a not used 0.O000E+00 3 a RADSHAPE(
7)
R017 Outer annular radius (m),
ring 8:
not used a O.000E+00 ADSHAPE(
8)
R017 Outer annular radius (m),
ring 9:
a not used O.O000E+00 a
ADSHAPE( 9)
R017 a Outer annular radius (m),
ring 10:
not used a 0.000E+00 a--
RADSHAPE(I0)
R017 a Outer annular radius (m),
ring 11:
not used O.000+00 a--
RADSHAPE(11)
R017 Outer annular radius (m),
ring 12:
a not used a 0O00OE+00 I
-a-RADSHAPE(12)
R017 Fractions of annular areas within AREA:
R017 a Ring 1
a not used a 1.000E+00 a--
FRACA( 1)
R017 a Ring 2
not used a 2.732E-01 FRACA( 2)
R017 a Ring 3
not used a O.oO0E+O0 FRACA( 3)
R017 Ring 4
a not used 0.O000E+00 FRACA( 4)
R017 Ring S
not used O.000E+00 FRACA( 5)
R017 Ring 6
not used O.00E+00 a FRACA( 6)
R017 a Ring 7
not used a O.000E+00 FRACA( 7)
R017 a Ring 8
not used O.0OE+O0 a FRACA( 8)
R017 a Ring 9
a not used O.O0E+O0 a a FRACA( 9)
R017 a Ring 10 a not used a O.000E+00 FRACA(10)
R017 a Ring 11.
a not used a O.000E+00 a-a FRACA(11)
R017 a Ring 12 not used 0.000E+00 a FRACA(12)
RO18 a Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 a DIET(a )
R018 a Leafy vegetable consumption (kg/yr) a 2.140E+01 a 1.400E+01 a--DIE(2)
R018 a Milk consumption (L/yr) a 2.330E+02 9.200E+01 a-a DIET(3)
R018 a Meat and poultry consumution (kg/yr) a 6.510E+01 a 6.300E+01 a a DIET(4)
R018 a Fish consumption (kg/yr) a 2.060E+01 5.400E+00 a DIET(S)
R018 other seafood consumption (kg/yr) 9.000E-01 9.000E-01 a--DIET(6)
RO18 a Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 SOIL R018 a Drinking water intake (L/yr) 4.785E+02 5.100E+02 aDaWI R018 a Contamination fraction of drinkino water a 1.000+00 a 1.0006+00 a
FDW R018 a Contamination fraction of household water a not used a 1.000E+00 a FHHW R018 Contamination fraction of livestock water a 1.000E+00 a 1.000E+00 FLW R018 a Contamination fraction of irrigation water a 1.000E+O0 1.000E+00 a--
FIRW R018 a Contamination fraction of aquatic food 1.OO0E+0O 5.000E-01 a--
FR9 RO8 Contamination fraction of plant food a1.006E+O0 a'-1 a
FPLANT R018 a Contamination fraction of meat a 1.00OE+00
-1 a
FMEAT RO18 Contamination fraction of milk a 1.000E+00 :-1 a-a FMILK R019 Livestock fodder intake for meat (kg/day) a 2.710E+01 a 6.800E+01 a LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 a 5.500E+01 a--
LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 a 3.000E+01 LWI5 1RESRAD, Version 6.5 Tin Limit = 30 days 11/28/2011 11:51 Page 7
Summary : HB soil DCGL_Pu240 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU240 DCGL\\HB SOIL DCGL_PU240.RAD 0 n a
menu Parameter RO9 Livestock water intake for milk (L/
R019 Livestock soil intake (kg/day)
RO19 Mass loading for foliar deposition R019 Depth of soil mixing layer (m)
R019 Depth of roots (im)
ROl Drinking water fraction from ground ROla Household water fraction from grour Ro01 Livestock water fraction from groun R01g Irrigation fraction from ground wat R19B Wet weight crop yield for Non-Leaf R19B Wet weight crop yield for Leafy R19B Wet weight crop yield for Fodder R19B Growing Season for Non-Leafy (year R19B a Growing Season for Leafy (yeai R19B Growing Season for Fodder (year R19B Translocation Factor for Non-Leaf R19B Translocation Factor for Leafy R19B Translocation Factor for Fodder R19B Dry Foliar Interception Fraction fo R19B a Dry Foliar Interception Fraction f R19B a Dry Foliar Interception Fraction fo R19B Wet Foliar Interception Fraction fo R19B Wet Foliar Interception Fraction fc R19B Wet Foliar Interception Fraction fc R19B Weathering Removal Constant for Veg c14 C-12 concentration in water (g/cm*
C14 a C-12 concentration in contaminated C14 a Fraction of vegetation carbon from C14 a Fraction of vegetation carbon from C14 a C-14 evasion layer thickness in soi C14 ARC-14 evasion flux rate from soil C14 a C-12 evasion flux rate from soil IMBA RTLETT Site-Specific Parameter Summary (continued)
User a
a used by RESRAD input.
Default a (if di.fferent from user input)
'day) 6.000E+01 a 1.600E+02 a 5.OOOE-01 5.000E-01 a (g/m**3) 4.000E-04 1.000E-04 a 2.300E-01 1a500E 1.220E+00 9.000E-01 a d water a 1.000E+O0 1.000E+00 0
nd water a not used 1.000E+O0 a
nd water a 1.000E+00 a 1.000+0 aer 1.000E+00 1.0006E+OO (kg/m**2) 1.750E+00 7.000E-01 a (kg/m**2) 2.889E+00 1.500E+00 a (kg/m**2) 1.887E+00 1.100E+00 a rs) 2.460E-01 1.700E-01 a rs) 1.230E-01 2.500E-01 rs) 8.200E-02 a 8.000E-02 y
1.000E-01 1.OOOE-01 a 1.OOOE+00 1.0OOE+00 a 1.000E+00 1.000E+O0 a or Non-Leafy 3.500E-01 a 2.500E-01 a or Leafy 3.500E-01 a 2.500E-01 a--
or Fodder a 3.500E-01 a 2.500E-01 a or Non-Leafy 3.500E-01 a 2.500E-01 a or Leafy 5.800E-01 a 2.500E-01 a or Fodder 3.500E-01 a 2.500E-01 getation a 3.300E+01 a 2.000E+01
-3) a not used a 2.000E-05 soil (g/g) a not used a 3.000E-02 soil not used a 2.000E-02 air not used a 9.800E-01 il (m) not used a 3.000E-01 I/sec) a not used a 7.00OE-07 a 1/secl not used a 1.000E-10 A
Parameter aName a LWI6 a LSI a MLFD DM DROOT a FGWDW FGWHH FGWLW FGWIR YV(1)
Yv(2) a Yv(3)
TIV(2) aiv(3)
RDRY(1) a RDRY(2) a RDRY(3) a RWET(1) a RWET(2) a RWET(3)
WLAM C12WTR a C12CZ CSOIL CAIR DMC EVSN REVSN AAA Page 116
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 C14 Fraction of grain in beef cattle feed not used 8.000E-01 AVFG4 C14 Fraction of grain in milk cow feed not used 2.00E-0I 3--
AVFGS STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 STORT(1)
STOR Leafy vegetables i.O00E+00 1.000E+00 I-- STORT(2)
STOR Milk 1.O00E+O0 1.OOOE+O0
~--
STORT(3)
STOR Meat and poultry 2.000E+01 2.OOOE+01 STORT(4)
STOR Fish 7.O000E+00 7.000E+00 STORIT(S)
STOR Crustacea and mollusks 7.000E+0I 7.0OOE+O0 STOR-T(6)
STOR Well water 1.O00E+00 1.OOOE+00 STORT(7)
STOR Surface water 1.000E+O0 3 1.000E+00 S-roR_(8)
STOR Livestock fodder 4.500E+01 4.500E+01 STOR-T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 FLOORI R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 DENSFL IRESRAD, Version 6.5 Toc Limit = 30 days 11/28/2011 11:51 Page 8
Summary : HB soil DCGLPu240 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU240 DCGL\\HB SOIL DCGLPU240.RAD Site-Specific Parameter Summary (continued) 0 3
3 User U
Used by RESRAD Parameter Menu 3 Parameter Input..
Default 3.(if different from user input)
Name R021 Total porosity of the cover material not used 4.000E-01 TPCV R021 Total porosity of the building foundation not used 31.000E-01I TPFL R021 Volumetric water content of the cover material not used 5.0OOE-02 PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 DIFCV R021 in foundation material not used 3.000E-07 DIFFL R021 in contaminated zone soil not used 2.000E-06 DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 REXG R021 Height of the building (room)
(m) not used 2.500E+00 HRM R021 Building interior area factor not used O.000E+00 FAI R021 Building depth below ground surface (m) not used 3-1.0O0E+00 DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 EMANA(1)
R021 Emanating power of Rn-220 gas not used 3I.SOOE-01 EMANA(2)
TITL Number of graphical time points 32 NPTS TITL Maximum number of integration points for dose 17 LYMAX TITL Maximum number of integration points for risk 1
KYMAX Summary of Pathway Selections
.Pathway.
User Selection 1-external gamma 3
active 2
inhalation (w/o radon)'
active 3--
plant ingestion active 4
meat ingestion active 5
milk ingestion active 6
aquatic foods active 7--
drinking water active 8
soil ingestion active 9 --
radon suppressed Find peak pathway doses active iRESRAD, Version 6.5 Tmo Limit = 30 days 11/28/2011 11:51 Page 9
Summary : HB soil DCGL_Pu240 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU240 DCGL\\HB SOIL DCGL_PU240.RAD Contaminated Zone Dimensions Initial Soil Concentrations,..P.ci/g Area:
30000.00 square meters Pu-240 1.OOOE+00 Thickness:
2.67 meters Cover Depth:
0.00 meters IRESRAD, Version 6.5 Tco Limit = 30 days 11/28/2011 11:51 Page 1
Probabilistic results summary : HB soil DCGL_Pu240 File : C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\PU240 DCGL\\HB SOIL DCGL.PU240.RAD Table of Contents Part VI: Uncertainty Analysis ORESRAD Uncertainty Analysis Results Probabilistic Input..
2 Total Dose...
4 Total Risk...
5 Dose vs Pathway:
Ground External...................
6 Dose vs Pathway:
Inhalation (w/o Radon) 7 Dose vs Pathway:
Radon (water Ind.)................
8 Dose vs Pathway:
Plant (water Ind.)
9 Dose vs Pathway:
Meat (water Ind.)................
10 Dose vs Pathway:
Milk (water Ind.)................
11 Dose vs Pathway:
soil Ingestion.....................
12 Dose vs Pathway:
Water Ingestion...................
13 Dose vs Pathway:
Fish Ingestion.....................
14 Dose vs Pathway:
Radon (Water Dep.)
15 Dose vs Pathway:
Plant (Water Dep.)
16 Dose vs Pathway:
Meat (Water Dep.)
17 Dose vs Pathway:
Milk (Water Dep.)
18 Cumulative Probability Summary.......................
19 Summary of dose at graphical times, reptition 1...
20 Peak of the mean dose at graphical times.............
21 Correlation and Regression coefficients (if any).....
22 1RESRAD, Version 6.5 To Limit = 30 days 11/28/2011 11:51 Page 2
Probabilistic results summary : HB soil DCGL-Pu240 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU240 DCGL\\HB SOIL DCGL_PU240.RAD Probabilistic Input ONumber of Sample Runs: 2000 Number Name Distribution Parameters C7 ARTLETT Page 117
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 AAAXAAAAAAAAAAAAAA XAXXXXXXXXXX WXSXXXAXXXXXXRXXXXXX 1
DENSCZ BOUNDED NORMAL 1.5635
.2385
.827 2.3 2
TPCZ BOUNDED NORMAL
.41
.09
.1319
.6881 3
HCCZ ROUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 4
BCZ BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 5
EVAPTR UNIFORM
.5
.75 6
RI UNIFORM
.36
.76 7
DENSAQ BOUNDED NORMAL 1.5105
.1855
.937 2.084 8
TPSZ BOUNDED NORMAL
.43
.0699
.214
.646 9
EPSZ BOUNDED NORMAL
.342
.0705
.124
.56 10 HCSZ BOUNDED LOGNORMAL-N.362 1.59
.0106 195 11 BSZ BOUNDED LOGNORMAL-N 1.96
.265 3.02 15.5 12 DWIBWT TRIANGULAR 6
10 30 13 U1W UNIFORM 1173 1973 14 H(1)
UNIFORM 0
8.08 15 DENSUZ(1)
BOUNDED NORMAL 1.5635
.2385
.827 2.3 16 TPUZ(1)
BOUNDED NORMAL
.41
.09
.1319
.6881 17 EPUZ(1)
BOUNDED NORMAL
.315
.0905
.0349
.594 18 HCUZ(1)
BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 19 BUZ(1)
BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 20 MLINH CONTINUOUS LINEAR 8
0 0
.000008
.0151
.000016
.1365
.00003
.8119
.00004
.9495
.00006
.9937
.000076
.9983
.0001 1
21 SHF3 UNIFORM
.15
.95 22 SHF1 BOUNDED LOGNORMAL-N -1.3
.59
.044 1
23 DM TRIANGULAR 0
.15
.6 24 YV(1)
TRUNCATED LOGNORMAL-N.56
.48
.001
.999 25 WLAM TRIANGULAR 5.1 18 84 26 RWET(2)
TRIANGULAR
.06
.67
.95 27 DCACTC(1)
TRUNCATED LOGNORMAL-N 6.86 1.89
.001
.999 28 DCACTUI(1)
TRUNCATED LOGNORMAL 6.86 1.89
.001
.999 29 DCACTS(1)
TRUNCATED LOGNORMAL-N 6.86 1.89
.001
.999 30 DCACTC(3)
TRUNCATED LOGNORMAL-N 8.17 1.7
.001
.999 31 DCACTUI(3)
TRUNCATED LOGNORMAL-N 8.17 1.7
.001
.999 32 DCACTS(3)
TRUNCATED LOGNORMAL-N 8.17 1.7
.001
.999 33 DCACTC(4)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001
.999 34 DCACTU1(4)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001
.999 35 DCACTS(4)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001
.999 36 DCACTC(5)
TRUNCATED LOGNORMAL-N 8.68 3.63
.001
.999 37 DCACTUI(5)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001
.999 38 DCACTS(5)
TRUNCATED LOGNORMAL-N 8.68 3.62
.001
.999 39 DCACTC(6)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001
.999 40 DCACTU1(6)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001
.999 41 DCACTS(6)
TRUNCATED LOGNORMAL-N 4.84 3.13
.001
.999 42 BRTF(94,2)
TRUNCATED LOGNORMAL-N -9.21
.2
.001
.999 43 BRTF(94,3)
TRUNCATED LOGNORMAL-N -13.82
.5
.001
.999 44 BBIO(94,1)
LOGNORMAL-N 3.4 1.1 45 RRTF(88,1)
TRUNCATED LOGNORMAL-N -3.22
.9
.001
.999 46 BRTF(88,2)
TRUNCATED LOGNORMAL-N -6.91
.7
.001
.999 47 BRTF(88,3)
TRUNCATED LOGNORMAL-N -6.91
.5
.001
.999 48 BBIO(88,1)
LOGNORMAL-N 3.9 1.1 IRESRAD, Version 6.5 T' Limit = 30 days 11/28/2011 11:51 Page 3
Probabilistic results summary : HB soil DCGL-Pu240 File : C:\\RESRAD.FAMILY\\RESRAD\\6.S\\USERFILES\\PU240 DCGL\\HB SOIL DCGLPU240.RAD Probabilistic Input (cont.)
Number Name Distribution Parameters 49 BRTF(90,1)
TRUNCATED LOGNORMAL-N
-6.91
.9
.001
.999 50 BRTF(90,2)
TRUNCATED LOGNORMAL-N -9.21 1
.001
.999 51 BRTF(90,3)
TRUNCATED LOGNORMAL-N -12.21
.9
.001
.999 52 BBIO(90,1)
LOGNORMAL-N 4.6 1.1 53 BRTF(92,1)
TRUNCATED LOGNORMAL-N -6.21
.9
.001
.999 54 BRTF(92,2)
TRUNCATED LOGNORMAL-N -7.13
.7
.001
.999 55 BRTF(92,3)
TRUNCATED LOGNORMAL-N -7.82
.6
.001
.999 56 BBIO(92,1)
LOGNORMAL-N 2.3 1.1 ttflit tI titlifttiliffffttlll tfifttitiltittitfMt liifttiltttlifitftitttifitliffltl filfttt IRESRAD, Version 6.5 Ta< Limit = 30 days 11/28/2011 11:51 Page 21 Probabilistic results summary : HB soil DCGL-Pu240 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU240 DCGL\\HB SOIL DCGLPU240.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr I
O.O00E+00 9.357E-01 eWBARTLETT Page 118
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Pu-241 Results:
iRESRAD, version 6.5 T. Limit ý 30 days 11/28/2011 11:59 Page 1
Summary HB soil DCGL_Pu241 File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU241 DCGL\\HB SOIL DCGLPU241.RAD Table of Contents r Mixture Sums amd Simle Radionuclide Guidelines i1ttfflitttlt~titffIitlf ill il fi ttitifffittt1 fitl Dose Conversion Factor (and Related) Parameter Ssummary...
2 Site-Specific Parameter Summary............................
4 Summary of Pathway Selections..............................
8 Contaminated Zone and Total Dose Summary...................
9 Total Dose Components Time = 0.O00E+00.......................................
10 Time = 1.000E+00.....................................
11 Time = 3.000E+00.
12 Time = 1.000E+01..
13 Time = 3.000E+01.
14 Time = 1.O00E+02 15 Time = 3.000E+02..
16 Time = 1.000E+03..
17 Dose/Source Ratios Summed Over All Pathways..............
18 Single Radionuclide Soil Guidelines.......................
18 Dose Per Nuclide Summed Over All Pathways.................
19 Soil Concentration Per Nuclide...........................
19 1RESRAD, Version 6.5 T. Limit = 30 days 11/28/2011 11:59 Page 2
Summary : HB soil DCGLPu241 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU241 DCGL\\HB SOIL DCGLPU241.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: HR DCGLs Plus FGR 12 & FGR 11 0
3 Current 3
Base 3 Parameter Menu 3 Parameter Value#
3 Case*
3 Name A-1 3 DCF's for external ground radiation, (mrem/yr)/(pci/g) 3 3
7 A-1 Ac-225 (Source: FGR 12) 6.371E-02 6.371E-02 DCFl(
1)
A-1I Am-241 (Source:
FGR 12) 4.372E-02 4.372E-02 3 DCFi(
2)
A-1 3 At-217 (Source:
FGR 12) 1.773E-03 1.773E-03 DCF1(
3)
A-1I Bi-213 (Source:
FGR 12) 7.660E-01 7.660E-01 DCF1(
4)
A-1 Fr-221 (Source:
FGR 12) 1.536E-01 I1.536E-01 DCFi(
5)
A-1 Np-237 (Source:
FGR 12) 7.790E-02 7.790E-02 DCF1(
6)
A-1 Pa-233 (Source:
FGR 12) 1.020E+00 1.020E+00 DCFI(
7)
A-1 Pb-209 (Source:
FGR 12) 7.734E-04 I 7.734E-04 DCF1(
8)
A-1 Po-213 (Source:
FGR 12) 0.O00E+00 O.OOOE+00 DCF1(
9)
A-1 Pu-241 (Source: FGR 12) 5.904E-06 5.904E-06 DCFI(
10)
A-1 Ra-225 (Source: FGR 12) 1.102E-02 1.102E-02 DCFi( 11)
A-i Th-229 (Source:
FGR 12) 3.213E-01 3.213E-01 DCFI(
12)
A-i TI-209 (Source:
FGR 12) 1.293E+01 1.293E+01 DCF1( 13)
A-1 u-233 (Source:
FGR 12) 1.397E-03 1.397E-03 DCFi(
14)
A-1 u-237 (Source:
FGR 12) 5.306E-01 5.306E-01 DCFi(
15)
B-i Dose conversion factors for inhalation, mrem/pCi:
B-1 Am-241 4.440E-01 4.440E-01 DCF2(
1)
B-1 Np-237+D 5.400E-01 5.400E-01 DCF2(
2)
B-1 Pu-241 8.250E-03 8.250E-03 DCF2(
3)
B-1 Pu-241+D 8.254E-03 8.250E-03 DCF2(
4)
B-1 Th-229+D 2.169E+00 2.150E+00 DCF2(
5)
B-1 u-233 1.350E-01 1.350E-01 DCF2(
6)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Am-241 3.640E-03 3.640E-03 DCF3(
1) c-1 Np-237+D 4.444E-03 4.440E-03 DCF3(
2)
D-1 Pu-2 41 6.840E-05 6.840E-05 DCF3(
3)
D-1 Pu-241+D 7.157E-05 6.840E-05 DCF3(
4)
D-1 Th-229+D 4.027E-03 3.530E-03 DCF3(
5)
D-1 u-233 2.890E-04 2.890E-04 DCF3(
6)
D-34 Food transfer factors:
D-34 Am-241 plant/soil concentration ratio, dimensionless 1.830E-03 1.000E-03 RTF(
1,1)
D-34 3Am-241 beef/livestock-intake ratio, (pci/kg)/(pci/d) 5.OOE-OS 5.000E-05 RTF(
1,2)
D-34 Am-241 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.000E-06 2.000E-06 RTF(
1,3)
D-34 D-34 Np-237+D
, plant/soil concentration ratio, dimensionless 3.670E-02 2.000E-02 RTF(
2,1)
D-34 Np-237+D beef/livestock-intake ratio, (pci/kg)/(pCi/d) 1.OOOE-03 1.OOO-03 RTF(
2,2)
D-34 Np-237+D milk/livestock-intake ratio, (pCi/L)/(pCi/d) 5.OOOE-06 5.000E-06 RTF(
2,3)
D-34 D-34 Pu-241
, plant/soil concentration ratio, dimensionless 1.830E-03 1.000E-03 RTF(
3,1)
D-34 Pu-241 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-04 1.OOOE-04 RTF(
3,2)
D-34 Pu-241 milk/livestock-intake ratio, (pCi/L)/(pci/d)
'1.000E-06 1.000E-06 RTF(
3,3)
D-34I D-34 Pu-241+D
, plant/soil concentration ratio, dimensionless 1.830E-03 1.000E-03 RTF(
4,1)
D-34 Pu-241+D beef/livestock-intake ratio, (pCi/kg)/(pci/d) 1.000E-04 1.000E-04 RTF(
4,2)
D-34 Pu-241+D milk/livestock-intake ratio, (pCi/L) /(pCi/d) 1.000E-06 1.000E-06 RTF(
4,3)
D-34 IRESRAD, version 6.5 T-Limit = 30 days 11/28/2011 11:59 Page 3
Summary : HB soil DCGL-Pu241 File
- C:\\RESRAD.FAMILY\\RESRAD\\6.5\\USERFILES\\PU241 DCGL\\HB SOIL DCGCL.PU241.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)
Dose Library: HB DCGLs Plus FGR 12 & FGR 11 0
1
' Current I
Base 3
Parameter Menu 3Parameter value#
Case Name D-34 Th-229+D plant/soil concentration ratio, dimensionless
' 1.000E-03 ' 1.000E-03 RTF(
5,1)
D-34 Th-229+c beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-04 1.000E-04 RTF(
5,2)
D-34 Th-229+D milk/livestock-intake ratio, (pCi/L /(pCi/d) 5.000E-06 3 5.OOOE-06 RTF(
5,3)
D-34 D-34 u-233 plant/soil concentration ratio, dimensionless 2.500E-03 2.500E-03 RTF(
6,1)
D-34 u-233 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 3.400E-04 3.400E-04 RTF(
6,2)
D-34 U-233 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 6.000E-04 6.000E-04 RTF(
6,3)
D-S Bioaccumulation factors, fresh water, L/kg:
D-5 Am-241
, fish 3.OOOE+01 3.OOOE+01 BIOFAC(
1,1)
D-S Am-241
, crustacea and mollusks 1.000E+03 1.000E+03 BIOFAC(
1,2)
D-5 00 8A RT LE T-T Page 119
Bartlett Engineering Humboldt Bav Soil DCGLs ENG-HB-003 Rev. 0 D-S Np-237+D
, fish 3.000E+01 3.000E+01 BIOFAC(
2,1)
D-5 Np-237+D
, crustacea and mollusks 4.000E+02 4.000E+02 BIOFAC(
2,2)
D-5 D-5 Pu-241
, fish 3.000E+O1 3.OOOE+01 BIOFAC(
3,1)
D-5 Pu-241
- crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC(
3,2)
D-5 3
D-5 Pu-241+D
, fish 3.000E+01 3.000E+01 BIOFAC(
4,1)
D-5 Pu-241+D
, crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC(
4,2) 0-S a
D-5 Th-229+D
, fish 1.000E+02 1.000E+02 BIOFAC(
5,1)
D-5 Th-229+D
, crustacea and mollusks 5.O00E+02 5.000E+02 BIOFAC(
5,2)
D-S D-5 u-233
, fish 1.OOOE+01 1.000E+01 3 BIOFAC(
6,1)
D-5 u-233
. crustacea and mollusks 6.OOOE+0I 6.000E+01 3 BIOFAC(
6 2)
- For DCFl(xxx) only, factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Default.Lib w/o Associate Nuclide contributions.
IRESRAD, Version 6.5 Tc' Limit = 30 days 11/28/2011 11:59 Page 4
Summary HB soil DCGLPu241 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU241 DCGL\\HB SOIL DCGLPU241.RAD Site-Specific Parameter Summary 0
3 User used by RESRAD Parameter menu 3Parameter 3 Ipý I(fdf n
ROll ROll ROll ROll ROll ROll ROll ROll ROll ROll ROll ROll R011 R011 R011 R011 R011 Rol2 R013 R013 R011 RO3 Roll R011 RO3 R013 R013 RO13 R013 R013 R013 RO3 RO13 R013 R013 R013 R013 R014 RO4 R014 R014 R013 RO4 R014 ROI4 R014 R014 R014 Area of contaminated zone (m**2)
Thickness of contaminated zone (m)
Fraction of contamination that is submerged Length parallel to aquifer flow (m)
Basic radiation dose limit (mrem/yr)
Time since placement of material (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Initial principal radionuclide (pCi/g):
Pu-241 Concentration in groundwater (pCi/L):
Pu-241 Cover depth (m)
Density of cover material (g/cm**
3)
Cover depth erosion rate (m/yr)
Density of contaminated zone (g/cm**3)
Contaminated zone erosion rate (m/yr)
Contaminated zone total porosity Contaminated zone field capacity Contaminated zone hydraulic conductivity (m/yr)
Contaminated zone b parameter Average annual wind speed (m/sec)
Humidity in air (g/m**3)
Evapotranspiration coefficient Precipitation (m/yr)
Irrigation (m/yr)
Irrigation mode Runoff coefficient watershed area for nearby stream or pond (m**2)
Accuracy for water/soil computations Density of saturated zone (g/cm**3)
Saturated zone total porosity Saturated zone effective porosity Saturated zone field capacity Saturated zone hydraulic conductivity (m/yr)
Saturated zone hydraulic gradient Saturated zone b parameter water table drop rate (m/yr) well pump intake depth (m below water table)
Model: Nondispersion (ND) or Mass-Balance (MB) well pumping rate (m**3/yr)
A AAA AAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA 3.OOOE+/-04 1.000E+04 2.670E+00 2.000E+00 0.OOE+-*00 0.000E+00 1.950E+02 1.000E+02 2.500E+01 3.000E+01 O.OOOE+00 0.00OE+00 1.000E+O0 1.00OE+00 3.000E+O0 3.000E+00 l.OOOE+01 1.O00E+01 3.000E+01 3.0006E+1 1.000E+02 31.000E+02 3.OOOE+02 3.000E+02 1.OO0E+03 1.000E+03 not used O000OE+00 not used 0.OOOE+00 I.OOOE+00 0.OOOE+0O not used O.OOOE+00 O.OOOE+00 0.O00E+00 not used 1.500E+00 not used 1.O000E-03 1.564E+00 1.500E+00 2.200E-03 1.000E-03 4.100E-01 4.000E-01 9.500E-02 2.000E-O1 3.900E+00 1.000E+01 5.600E+00 5.300E+00 3.040E+00 2.000E+00 not used 8.000E+00 6.250E-01 5.000E-01 9.100E-01 1.000E+00 5.600E-01 2.000E-01 overhead overhead 5.000E-01 2.OOOE-01 2.520E+07 1.000E+06 1.000E-03 1.000E-03 1.510E+00 1.500E+00 4.300E-01 4.000E-01 3.420E-01 2.000E-01 8.800E-02 2.000E-01 2.880E+01 31.000E+02 2.000E-03 I 2.000E-02 7.100E+00 5.300E+00 1.000E-03 1.O00E-03 1.00E+O1 1.O000E+01 ND 3 NO 1.573E+03 2.500E+02 Used by RESBAD different from user 9.5656-05 not used 7.5986-06 not used AREA THICKO SUBMFRACT LCZPAQ BRDL TI T( 2)
T( 3)
T( 4)
T(
5)
-r( 6)
T(
7)
T(
8)
T(
9)
T(10) s1(3) wl( 3)
COVERO DENSCV IVCV 3 DENSCZ I VCZ
' TPCZ 3 FCCZ I HCCZ 3 BC 3 WIND HUMID EVAPTR PRECIP RI IDITCH RUNOFF 3 WAREA 3 EPS DENSAQ TPSZ EPSZ FCSZ HCSZ HGW'T BSZ VW'T DWIBWT MODEL UW 3Parameter inpu )
.... Nam.......
NS H(1)
DENSUZ(1) 3TPUZ(1)
'EPUZ(1) 3ECUZ(1)
BUZ(1)
HCUZ(1)
DCNUCC( 3)
DCNUCU( 3,1)
DCNUCS( 3)
ALEACH (3)
SOLUBK( 3)
DCNUCC (I)
DCNUCU( 1,1)
DCNUCS(I1) 3ALEACH( 1)
SOLUBK(I1)
DCNUCC( 2)
DCNUCU( 2,15 DCNUCS
( 2)
ALEACH( 2)
IRESRAD Version 6.5 T', Limit = 30 days 11/28/2011 11:59 Page 5
Summary : HB soil DCGLPu241 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\PU241 DCGL\\HB SOIL DCGLPU241.RAD Site-Specific Parameter Summary (continued) 0 1
User Menu Parameter Inpu.De........................f...............
....... D ault C. if R015 Number of unsaturated zone strata 1
1 1
R015 Unsat. zone 1, thickness (m) a 4.040E+00 4.000E+00 R015 unsat. zone 1, soil density (g/cm**3)
I 1.564E+00 1.500E+00 R015 Unsat. zone 1, total porosity I 4.100E-01 4.000E-O1 R015 unsat. zone 1, effective porosity I 3.150E-01 2.000E-O1 R015 Unsat. zone 1, field capacity
.9.500E-02 2.000E-01 RO15 Unsat. zone 1, soil-specific b parameter 5.600E+00 5.300E+00 R015 Unsat. zone 1, hydrau1ic conductivity (m/yr) 3.900E+00 1.O00E+01 R016 Distribution coefficients for Pu-241 R016 3 Contaminated zone (cm**3/g) 3 9.530E+02 2.000E+03 R016 unsaturated zone 1 (cm*3/g)
I 9.530E+02 2.000E+03 R016 Saturated zone (cm.*3/g) 9.530E+02 2.000E+03 R016 Leach rate (/yr) 0.OOOE+00 0.0O0E+O0 R016 solubility constant O.000E+00 O.000E+00 R016 Distribution coefficients for daughter Am-241 R016 Contaminated zone (cm**3/g) 1.200E+04 2.000E+01 R016 Unsaturated lone 1 Ccm tm3/g) 1.445E+03 2.0006+01 R016 Saturated zone (cm t3/g) 1.445E+03 2.000E+01 R016 Leach rate (/yr)
O.000E+00 0.000E+00 R016 solubility constant O.000E+00 0.O00E+00 R016 Distribution coefficients for daughter Np-237 3
R016 Contaminated zone (cm*3/g) 1.700E+01 '-1.000E+00 RO6 unsaturated zone 1 (cm**3/g) 1.700E+01 '-1.000E+00 R016 3 Saturated zone (cm**3/g) 1.700E+01 3-1.000E+O0 R016 Leach rate (/yr)
O.000E+00 3 0.00OE+00 t
BARTLETT 9 ?94E-03 Page 120 Page 120
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R016 Solubility constant 0.OOOE+0O 0.OOOE+OO R016 Distribution coefficients for daughter Th-229 R016 Contaminated zone (cm**3/g) 5.884E+03 6.O0OE+04 ROt6 unsaturated zone 1 (cm**3/g) 5.884E+03 6.000E+04 R016 Saturated zone (cm**3/g) 5.884E+03 I 6.000E+04 R016 Leach rate (/yr)
O.000E+00 3 0.000E+-40O RO16 solubility constant O.OOOE+00 a 0.000E+0O R016 Distribution coefficients for daughter u-233 R016 contaminated zone (cmcn3/g) 1.260E+02 5.OOOE+01 R016 unsaturated zone 1 (cm.*3/g) 1.260E+02 S.O00E+01 R016 Saturated zone (cm**3/g) 1.260E+02 3 5.000E+01 ROI6 Leach rate (/yr) 0.OOOE+00 O.000E+00 R016 Solubility constant 0.0O0E+00 0.OOOE+00 R017 Inhalation rate (m**3/yr) 8.400E+03 3 8.400E+03 R017 Mass loading for inhalation (g/m**3) 1.000E-04 I 1.000E-04 R017 Exposure duration 3.000E+01 I 3.000E+01 R017 Shielding factor, inhalation 5.500E-01 3 4.000E-01 R017 Shielding factor, external gamma 2.725E-01 3 7.000E-01 R017 Fraction of time spent indoors 6.571E-01 ' 5.000E-01 IRESRAD, version 6.5 T6 Limit = 30 days 11/28/2011 11:59 Page 6
Summary : HB soil DCGLPu241 File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU241 DCGL\\HB SOIL DCGL_PU241.RAD Site-Specific Parameter Summary (contint not used 1.550E-05 not used 7.224E-04 not used SOLUBK(
2)
DCNUCC(
5)
DCNUCU( 5,1)
- DCNUCS( 5)
ALEACH( 5)
SOLUBK( 5)
DCNUCC( 6)
DCNUCU( 6,1)
DCNUCS( 6)
ALEACH( 6)
SOLUBK( 6)
INHALR MLINH ED SHF3 a SHF1 3FIND 0
User 3
Menu aParameter Iniput a DefaultI R017 Fraction of time spent outdoors Con site) a.181E-Ol 2.500E-01 ROl7 Shape factor flag, external gamma 1.O0OE+00 1.000E+00 R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m),
ringI1.
not used 5.0006+01 ROl7 Outer annular radius (m),
ring 2:
not used a 7.071E+01 R017 Outer annular radius (m),
ring 3:
not used 0.000E+00 R017 Outer annular radius (m),
ring 4:
not used 0.00OE+00 R017 Outer annular radius (m),
ring 5:
not used a 0.000E+00 R017 Outer annular radius (m),
ring 6:
not used 0.0OE+00 3
R017 Outer annular radius (m),
ring 7:
a not used 0.00OE+OO R017 Outer annular radius (m),
ring 8:
not used 0.000E+0O R017 Outer annular radius (m),
ring 9:
not used 0.0OOE+00 R017 Outer annular radius (m),
ring 10:
not used 0.O00E+O0 R017 Outer annular radius (m),
ring 11:
not used 0.OO0E+0O R017 Outer annular radius (m),
ring 12:
not used 0.OOOE+0O R017 Fractions of annular areas within AREA:
a ROl7 Ring 1
not used 1.OO0E+00 R017 Ring 2
a not used 2.732E-01 R017 Ring 3
a not used 0.00OE+00 RO17 a Ring 4
not used a 0.OOOE+00 R017 Ring 5
not used 0.000E+00 a R017 Ring 6
not used 0.000E+00 R017 a Ring 7
not used a 0.000E+0O RO17 3 Ring 8
not used 0.O00E+00 R017 Ring 9
not used O.000E+00 ROll Ring 10 not used 0.000E+0O R017 Ring 11 not used 0.OOOE+00 RO17 Ring 12 not used O.000E+00 R018 Fruits, vegetables and grain consumption (kg/yr)
I.120E+02 1.600E+02 R018 Leafy vegetable consumption Ckg/yr) 2.140E+01 1.400E+01 R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 R018 Other seafood consumption (kg/yr) 9.OOOE-01 9.O0OE-01 R018 soil ingestion rate (g/yr) 1.826E+01 3.650E+01 R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 R018 Contamination fraction of drinking water 1,0O0E+003
.OOOE+00 R018 Contamination fraction of household water 3 not used 1.000E+0O0 R018 Contamination fraction of livestock water 1.000E+00 1.0O0E+00 R018 Contamination fraction of irrigation water
.3 1.00OE+00 1.000E+00 R018 Contamination fraction of aquatic food 3 1.000E+00 5.000E-01 R018 Contamination fraction of plant food 1.0006E+0O
-1 R018 Contamination fraction of meat 1.000E+00 '-I R018 Contamination fraction of milk 1.000E+00 a 1 R019 Livestock fodder intake for meat (kg/day) 3 2.710E+01 3 6.800E+013 R019 a Livestock fodder intake for milk (kg/day) 6.320E+01 I 5.500E+01 a R019 Livestock water intake for meat (L/day) 5.060E+01 I 5.000E+01 IRESRAD, Version 6.5 T' Limit = 30 days 11/28/2011 11:59 Page 7
Summary : HB soil DCGLPu241 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU241 DCGL\\HB SOIL DCGL.Pu241.RAD Site-Specific Parameter Summary (contint 0
3 o User 3
Menu Parameter................
3 Input 3 Default a
R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.OOOE-04 R019 Depth of soil mixing layer (m) a 2.300E-01 1.50OE-01 R019 Depth of roots (m) 1.220E+00 9.000E-01 R019 Drinking water fraction from ground water 1.000E+0O 1.000E+00 R019 Household water fraction from ground water not used 1.000E+00 R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 R19B Wet weight crop yield for Non-Leafy (kg/m*2) 1.750E+00 a 7.000E-01 R198 wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 R198 wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 R19i Growing Season for Non-Leafy (years) a 2.460E-01 1.700E-01 a R19B Growing Season for Leafy (years) 1.230E-01 2.S00E-01 R198 Growing Season for Fodder (years) 8.200E-02 8.000E-02 R198 Translocation Factor for Non-Leafy 1.000E-01 1.00OE-01 R19B Translocation Factor for Leafy 1.OO0+00 1.000E+00 R19B Translocation Factor for Fodder 1.000E+00 1.OOOE+00 R198 Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.50OE-01 R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 a RI19 Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 t
BARTLETT ued)
Used by RESRAD Parameter (If different from user input)
Name............
LAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
>0 shows circular AREA.
FOTD a FS RADSHAPE( 1)
RADSHAPE(
2)
RAD_SHAPE( 3)
RADSHAPE( 4)
RADSHAPE(
5)
RAD_SHAPE( 6)
RADSHAPE( 7)
RADSHAPE(
8)
RADSHAPE(
9)
RADSHAPE(10)
RADSHAPE(11)
RADSHAPE(12)
FRACAC 1) 3 FRACA( 2) a FRACAC 3) 3 FRACA( 4)
' FRACA( 5) a FRACA( 6) a FRACAC 7)
FRACA(C )
FRACAC 9)
FRACA(10)
FRACA(11)
FRACA(12)
DIET(I)
DIET(2)
DIET(3) a DIET(4) a DIET(5)
DIET(6)
SOIL DWI FDW FHHW FLW FIRW FR9 FPLANT FMEAT FMILK LFIS LF16 LW15 ued) used by RESRAD Parameter (if different from user input)
Name LWI6
- -LSI
-- MLFD 3-DM DROOT a FGWDW FGWNHH FGWLW
-- FGWIR
- YV(1)
YV(2)
Yv(3) a TE(1) a-TE(2) a-TE(3)
TIV(1)
-- TIV(2) a-TIV(3)
-- RDRY(1)
RDRY(2)
-- RDRY(3)
RWETC1)
AA Page 121
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 R19B 3 Wet Foliar Interception Fraction for Leafy 5.800E-01 2.SOOE-01 3 RWET(2)
R19B I Wet Foliar Interception Fraction for Fodder 3.50OE-01 a 2.500E-01 RWET(3)
R19B Weathering Removal Constant for Vegetation 3.300E+01 2.OOOE+01 a-a WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 a--
Cl2WTR C14 C-12 concentration in contaminated soil (g/g) not used a 3.000E-02 C12CZ C14 Fraction of vegetation carbon from soil not used a 2.000E-02 CSOIL C14 a Fraction of vegetation carbon from air not used a 9.800E-01 aCAIR C14 a C-14 evasion layer thickness in soil (m) a not used a 3.000-01 DMC C14 C-14 evasion flux rate from soil (i/sec) a not used a 7.0OOE-07 EVSN C14 C-12 evasion flux rate from soil (i/sec) not used 1.000E-10 a-a REVSN C14 Fraction of grain in beef cattle feed not used 8.OOOE-01 a-a AVFG4 C14 Fraction of grain in milk cow feed not used a 2.000E-01 a-a AVFG5 STORP Storage times of contaminated foodstuffs (days): a STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 a-a STORT(1)
STOR Leafy vegetables a 1.OO0E+O0 1.0O0E+00 a STORT(2)
STOR Milk 1.000E+00 a 1.000E+00 a-a SToR_.j(3)
STOR Meat and poultry 2.OO0E+O1 2.oooE+01 a-a STORJT(4)
STOR Fish 7.000E+00 7.000E+O0 STORT(5)
STOR Crustacea and mollusks 7.OO0E+O0 7.OOOE+00 a-a STODR(6)
STOR well water 1.O00E+00 1.0O0E+00 a STOR.T(7)
STOR Surface water 1.OOOE+00 a 1.OOOE+00 a-a STOR_T(8)
STOR a Livestock fodder 4.500E+01 4.SOOE+01 a-a STORT(9)
R021 Thickness of building foundation (m) not used 1.500E-01 a-a FLOORI R021 Bulk density of building foundation (g/cm**3) a not used 2.4006+00 a DENSFL IRESRAD, Version 6.5 T1 Limit = 30 days 11/28/2011 11:59 Page 8
Summary :
B soil DCGL_Pu241 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU241 DCGL\\HB SOIL DCGLPU241.RAD Site-Specific Parameter Summary (continued)
O a
a User 3
a Used by RESRAD a Parameter Menu a Parameter a
n Iput 3 Default a (if different
- .r.*
.us...
i a
.Name R021 a Total porosity of the cover material a not used a 4.OOOE-01 a-a TP(V R021 Total porosity of the building foundation a not used a 1.OOOE-01 TPFL R021 volumetric water content of the cover material a not used a 5.000E-02 PH2OCV R021 a volumetric water content of the foundation not used a 3.OOOE-02
'-a PH2OFL R021 a Diffusion coefficient for radon gas (m/sec):
R021 in cover material a not used a 2.OOOE-06 a DIFCV R021 in foundation material a not used a 3.OOOE-07 DIFFL R021 in contaminated zone soil a not used a 2.OOOE-06 DIFCZ R021 Radon vertical dimension of mixing (m) a not used a 2.000E+00 a a HMIX R021 a Average building air exchange rate (1/hr) a not used a s.OOoE-01 REXG R021 Height of the building (room)
(m) a not used a 2.500E+00 HRM R021 Building interior area factor a not used O.O00E+00 FAI R021 Building depth below ground surface (m) a not used a-Q.000E+0 0 DMFL R021 a Emanating power of Rn-222 gas a not used a 2.500E-01 a a EMANA(1)
R021 Emanating power of Rn-220 gas a not used a 1.500E-01 EMANA(2)
TITL a Number of graphical time points a
32 a
a--
a--
NPTS TITL 3 Maximum number of integration points for dose 3
17 a
3 a LYMAX TITL 3 Maximum number of integration points for risk k 1
3 a KYMAX Summary of Pathway Selections
.Pathway a
User Selection A.....
external gamma a
active 2
inhalation (w/o radon)3 active 3-- plant ingestion a
active 4
meat ingestion active 5
milk ingestion active 6
aquatic foods active 7
drinking water active 8
soil ingestion active 9 --
radon suppressed Find peak pathway doses a
active IRESRAD, Version 6.5 Ta Limit = 30 days 11/28/2011 11:59 Page 9
Summary : HB soil DCGLPu241 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\PU241 DCGL\\HB SOIL DCGLPU241.RAD Contaminated Zone Dimensions Initial Soil Concentrations.pci/g Area:
30000.00 square meters Pu-241 1.000E+00 Thickness:
2.67 meters Cover Depth:
0.00 meters IRESRAD, Version 6.5 Tx Limit = 30 days 11/28/2011 11:59 Page. I Probabilistic results summary : HB soil DCGLPu241 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU241 DCGL\\HB SOIL DCGLPU241.RAD Table of Contents Part VI: Uncertainty Analysis ORESRAD Uncertainty Analysis Results probabilistic Input..
2 Total Dose..
4 Total Risk...
5 Dose vs Pathway:
Ground External....................
6 Dose vs Pathway:
Inhalation (w/o Radon)".............
7 Dose vs Pathway:
Radon (Water Ind.)................
8 Dose vs Pathway:
Plant (Water Ind.)
9 Dose vs Pathway:
Meat (Water Ind.)
10 Dose vs Pathway:
Milk (water Ind.)
11 Dose vs Pathway:
Soil Ingestion....................
12 Dose vs Pathway:
Water Ingestion...................
13 Dose vs Pathway:
Fish Ingestion.....
14 Dose vs Pathway:
Radon (water Dep.)
15 Dose vs Pathway:
Plant (water Dep.)
16........16 Dose vs Pathway:
Meat (Water Dep.)
17 Dose vs Pathway:
Milk (water Dep.).................
18 Cumulative Probability Summary.......................
19 t
BARTLETT Page 122
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Summary of dose at graphical times, reptition 1.....
20 Peak of the mean dose at graphical times.............
21 Correlation and Regression coefficients (if any).....
22 IRESRAD, version 6.5 T< Limit = 30 days 11/28/2011 11:59 Page 2
probabilistic results summary : HB soil DCGLPu241 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU241 DCGL\\HB SOIL DCGLPU241.RAD probabilistic Input ONumber of Sample Runs: 2000 Number Name Distribution Parameters 1
DENSCZ BOUNDED NORMAL 1.5635
.2385
.82 2
TPCZ BOUNDED NORMAL
.41
.09
.13 3
HCCZ BOUNDED LOGNORMAL-N 1.36 2.17
.00 4
BCZ BOUNDED LOGNORMAL-N 1.73
.323 2.0 5
EVAPTR UNIFORM
.5
.75 6
RI UNIFORM
.36
.76 7
DENSAQ BOUNDED NORMAL 1.5105
.1855
.93 8
TPSZ BOUNDED NORMAL
.43
.0699
.21 9
EPSZ BOUNDED NORMAL
.342
.0705
.12 10 HCSZ BOUNDED LOGNORMAL-N.362 1.59
.01 11 BSZ BOUNDED LOGNORMAL-N 1.96
.265 3.0 12 DWIBWT TRIANGULAR 6
10 30 13 UW UNIFORM 1173 1973 14 H(1)
UNIFORM 0
8.08 15 DENSUZ(1)
BOUNDED NORMAL 1.5635
.2385
.82 16 TPUZ(1)
BOUNDED NORMAL
.41
.09
.13 17 EPUZ(1)
BOUNDED NORMAL
.315
.0905
.03 18 NCUZ(1)
BOUNDED LOGNORMAL-N 1.36 2.17
.00 19 BUZ(1)
BOUNDED LOGNORMAL-N 1.73
.323 2.0 20 MLINH CONTINUOUS LINEAR 8
0 0
.00003
.8119
.00004
.9495
.00006
.9937
.000076
.9983 21 SHF3 UNIFORM
.15
.95 22 SHF1 BOUNDED LOGNORMAL-N -1.3
.59
.04 23 DM TRIANGULAR 0
.15
.6 24 YV(1)
TRUNCATED LOGNORMAL-N.56
.48
.00 25 WLAM TRIANGULAR 5.1 18 84 26 RWET(2)
TRIANGULAR
.06
.67
.95 27 DCACTC(3)
TRUNCATED LOGNORMAL-N 6.86 1.89
.00 28 DCACTU1(3)
TRUNCATED LOGNORMAL-N 6.86 1.89
.00 29 DCACTSC3)
TRUNCATED LOGNORMAL-N 6.86 1.89
.00 30 DCACTUi(1)
TRUNCATED LOGNORMAL-N 7.28 3.15
.00 31 DCACTS(1)
TRUNCATED LOGNORMAL-N 7.28 3.15
.00 32 DCACTC(2)
TRUNCATED LOGNORMAL-N 2.84 2.25
.00 33 DCACTU1(2)
TRUNCATED LOGNORMAL-N 2.84 2.25
.00 34 DCACTS(2)
TRUNCATED LOGNORMAL-N 2.84 2.25
.00 35 DCACTC(6)
TRUNCATED LOGNORMAL-N 4.84 3.13
.00 36 DCACTUI(6)
TRUNCATED LOGNORMAL-N 4.84 3.13
.00 37 DCACTSC6)
TRUNCATED LOGNORMAL-N 4.84 3.13
.00 38 BRTF(94,I)
TRUNCATED LOGNORMAL-N -6.91
.9
.00 39 BRTF(94,2)
TRUNCATED LOGNORMAL-N -9.21
.2
.00 40 BRTF(94,3)
TRUNCATED LOGNORMAL-N -13.82
.5
.00 41 BBIO(94,1)
LOGNORMAL-N 3.4 1.1 42 BRTF(95,2)
TRUNCATED LOGNORMAL-N -9.9
.2
.00 43 BRTF(95,3)
TRUNCATED LOGNORMAL-N -13.12
.7
.00 44 BBIO(95,1)
LOGNORMAL-N 3.4 1.1 45 BRTF(93,1)
TRUNCATED LOGNORMAL-N -3.91
.9
.00 46 BRTF(93,2)
TRUNCATED LOGNORMAL-N -6.91
.7
.00 47 BRTF(93,3)
TRUNCATED LOGNORMAL-N -11.51
.7
.00 48 BBID(93,1)
LOGNORMAL-N 3.4 1.1 IRESRAD, Version 6.5 71, Limit = 30 days 11/28/2011 11:59 Page 3
Probabilistic results sumasry : HB soil DCGLPu241 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU241 DCGL\\HB SOIL DCGLPU241.RAD 7
2.3 19
.6881
'478 3190
'8 15.3 7
.4 4
.06
'2 7
19 49 478
'8 0001 4
'1
'1
'1
'1
'1
'1
'1
'1
'1
'1
'1
'1
'1
'1 1
'1
'1
'1
'1 1
2.084
.646
.56 195 15.5 2.3
.6881
.594 3190 15.3
.000008 1
1
.999
.0151
.000016
.1365
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999
.999 Probabilistic Input (cont.)
Number Name Distribution Parameters 49 BRTF(90,1)
TRUNCATED LOGNORMAL-N -6.91
.9
.001
.999 50 BRTF(90,2)
TRUNCATED LOGNORMAL-N -9.21 1
.001
.999 51 BRTF(90,3)
TRUNCATED LOGNORMAL-N -12.21
.9
.001
.999 52 BBIO(90,1)
LOGNORMAL-N 4.6 1.1 53 BRTF(92,1)
TRUNCATED LOGNORMAL-N -6.21
.9
.001
.999 54 BRTF(92,2)
TRUNCATED LOGNORMAL-N -7.13
.7
.001
.999 55 BRTF(92,3)
TRUNCATED LOGNORMAL-N -7.82
.6
.001
.999 56 BBIO(92,1)
LOGNORMAL-N 2.3 1.1 ftlilf Mfi1111iitfffifffiff If11f1111fff1if1f111ff ffiffffff1Iifffffffifflflfftflifftfifif IRESRAD, Version 6.5 T' Limit = 30 days 11/28/2011 11:59 Page 21 Probabilistic results summnary : HB soil DCGLPu241 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\PU241 DCGL\\HB SOIL DCGLPU241.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition.
Time of peak mean dose Peak mean dose Years mrem/yr 1
5.380E+01 2.904E-02 t
BARTLETT Page 123
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Sr-90 Results:
iRESRAD, Version 6.5 TI Limit = 30 days 11/28/2011 10:36 Page 1
Summary: HB sensitivity analysis.soil-Sr-90 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\SRgO DCGL\\HB SOIL DCGL.SR90.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary...
2 Site-Specific Parameter Summary...........................
3 Summary of Pathway Selections............................
7 Contaminated Zone and Total Dose Summary...................
8 Total Dose Components Time = O.OOOE+00..
9 Time = 1.O00OE+00.
10 Time = 3.00O E+00......................................
11 Time = 1.OOOE+01.....................................
12 Time = 3.OOOE+01.....................................
13 Time = 1.000E+02......................................
14 Time = 3.OOOE+02..
15 Time = 1.000E+03..
16 Dose/Source Ratios Summed Over All Pathways..............
17 single Radionuclide Soil Guidelines......................
17 Dose Per Nuclide Summed Over All Pathways................
18 Soil Concentration Per Nuclide.....................
18 1RESRAD, Version 6.5 To Limit = 30 days ii1/2/2011 10:36 Page 2
Summary : HB sensitivity analysis.soil.Sr-90 File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\SR90 DCGL\\HB SOIL DCGL.SR90.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: HB DCGLs Plus FGR 12 & FGR 11 0
3 Current a
Base Parameter menu Parameter 3
value#
I Case*
Name A-1 DCF's for external ground radiation, (mrem/yr)/(pci/g)
A-1 Sr-90 (Source: FGR 12) 7.043E-04 7.043E-04 DCF1(
1)
A-I Y-90 (Source:
FGR 12) 2.391E-02 2.391E-02 DCF1(
2)
B-1 Dose conversion factors for inhalation, mrem/pCi:
3 3)
B-1 a Sr-90+-
1.308E-03 1.300E-03 DCF2(
1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
3 D-1 Sr-90+D 1.528E-04 1.420E-04 DCF3(
1)
D-34 Food transfer factors:
D-34 Sr-90+D
, plant/soil concentration ratio, dimensionless 5.900E-01 3.000E-01 3 RTF(
1,1)
D-34 Sr-90+D beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 8.000E-03 8.00OE-03 RTF(
1,2)
D-34 Sr-90+D milk/livestock-intake ratio, (pCi/L)/(pci/d) 2.00OE-03 2.000E-03 RTF(
1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Sr-90+D
, fish 6.000E+01 6.000E+01 BIOFAC(
1,1)
D-5 Sr-90+D crustacea and mollusks
'`1.000E+02 1.000E+02 BIOFAC(
1.2)
- For DCF1(xxx) only, factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Default.Lib w/o Associate Nuclide contributions.
1RESRAD, Version 6.5 T< Limit = 30 days 11/28/2011 10:36 Page 3
Summary : HB sensitivity analysis.soil.Sr-90 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\SRS0 DCGL\\HB SOIL DCGLSR90.RAD Site-S 0
3 Menu 3Parameter R011 Area of contaminated zone (m**2)
R011 Thickness of contaminated zone (m)
R011 Fraction of contamination that is submerged R011 Length parallel to aquifer flow (m)
R011 Basic radiation dose limit (mrem/yr)
R011 Time since placement of material (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
ROil Times for calculations (yr)
R011 Times for calculations (yr)
ROil Times for calculations (yr)
R011 Times for calculations (yr)
R012 Initial principal radionuclide (pCi/g):
Sr-90 R012 Concentration in groundwater (pCi/L):
Sr-90 R013 Cover depth (m)
ROI3 Density of cover material (g/cm**3)
R013 Cover depth erosion rate (m/yr)
ROI3 Density of contaminated zone (g/cm**3)
R013 Contaminated zone erosion rate (m/yr)
R013 Contaminated zone total porosity R013 Contaminated zone field capacity R013 Contaminated zone hydraulic conductivity (m/yr)
R013 Contaminated zone b parameter R013 Average annual wind speed (m/sec)
R013 Humidity in air (g/m**3)
R013 Evapotranspiration coefficient R013 Precipitation (m/yr)
R013 Irrigation (m/yr)
R013 Irrigation mode R013 Runoff coefficient R013 watershed area for nearby stream or pond (mn*2)
R013 Accuracy for water/soil computations R014 Density of saturated zone (g/cm**3)
R014 Saturated zone total porosity R014 Saturated zone effective porosity R014 Saturated zone field capacity pecific Parameter Summary user used by RESRAD a
Parameter
'IInput 3Default
- (if di fferent from User input)'
Name AREA 3.000E+04 1.000E+04 2.670E+00 2.000E+00 O.000E+00 0.OOOE+00 1.950E+02 1.000E+02 2.500E+01I 3.000E+01 O.OOOE+00 O.OO0E+O0 1.000E+00 1.OOOE+00 3.000E+00 3.OOOE+0O 1.000E+03 1.000E+01 3.000E+01 3.000E+01 1.000E+02 1.00OE+02 3.000E+02 3 3.000E+02 1.000E+03 I.O000E+03 not used 0.000E+00 not useda O.000E+00 1.000E+00 0.000E+00 not used O.O00OE+OO O.OO0E+O0 O.000E+00 not used 31500E+00 not used 1.O00E-03 1.564E+00 1.500E+O0 2.200E-03 1.O00E-03 4.100E-01 a 4.000E-01 9.500E-02 2.000E-01 3.900E+00 1.000E+01 5.600E+00 5.300E+00 3.040E+00 2.0006E+0 not used 8.000E+00 6.250E-01 5.000E-01 9.100E-01 1.006E+00 5.600E-01 2.000E-01 overhead overhead a 5.000E-01I 2.00E-01 2.520E+07 1.OOOE+06 a1.000E-03 1.000E-03 1.510E+00 1.500E+00 4.300E-01 4.OOOE-01 3.420E-01 2.000E-01 8.800E-02 2.000E-01
'AREA THICKO 3 SUBMFRACT 3 LCZPAQ BRDL 3 TI T( 2) a T( 3) 3 T( 4).
3 T(
5) 3 T(
6) 3 T(
7) 3 T( 8) 3 T(
9)
' T(10) 3 SI(1)
W1( 1)
COVERO 3 DENSCV VCV DENSCZ 3 VCZ TPCZ FCCZ HCCZ BCZ WIND HUMID EVAPTR PRECIP RI IDITCH RUNOFF WAREA DENSAQ TPSZ EPSZ FCSZ 0 EA RTL ETT Page 124
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R014 I Saturated zone hydraulic conductivity (m/yr)
R014 3 Saturated zone hydraulic gradient R014 3 Saturated zone b parameter ROI4 3 water table drop rate (m/yr)
R014 - well pump intake depth (m below water table)
R014 3 Model: Nondispersion (ND) or Mass-Balance (MB)
R014 3 well pumping rate (m**3/yr) 2.880E+01 1.OOOE+02 3 2.OOOE-03 I 2.000E-02 3 7.100E+00 5.300E+00 1.OOOE-03 1.OOOE-03 1.OOOE+01 1.000E+01 l
' ND ND 3 1.573E+03 2.500E+02
' HCSZ 3 HGWT BSZ
.VWT 3 DWIBWT MODEL UW IRESRAD, version 6.5 To Limit = 30 days 11/28/2011 10:36 Page 4
Summary : HB sensitivity analysis.soilSr-90 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\SR90 DCGL\\HB SOIL DCGL_SR90.RAD Site-Specific Parameter Summary (continued) 0 1
User 3
menu 3Parameter 3
Input
'Default (if RO15 Number of unsaturated zone strata 1
1 R015 Unsat. zone 1, thickness (m) 4.040E+00 4.OOOE+00 R015 Unsat. zone 1, soil density (g/cm**3) 1.564E+00 1.500E+00 RO15 Unsat. zone 1, total porosity 4.100E-01 4.OOOE-O1I RO15 Unsat. zone 1, effective porosity 3.150E-01 2.OOOE-01 R015 Unsat. zone 1, field capacity 9.500E-02 2.OOOE-01 R015 Unsat. zone 1, soil-specific b parameter 5.600E+00 5.300E+00 RO5 Unsat. zone 1, hydraulic conductivity (m/yr) 3.900E+00 1.O00E+01 O
R016 Distribution coefficients for Sr-90 R016 contaminated zone (cm**3/g) 3.200E+01 3 3.OOOE+01 RO16 Unsaturated zone 1 (cm**3/g) 3.200E+01 3.OOOE+01 R016 Saturated zone (cm**3/g) 3.200E+01 3.000E+01 R016 Leach rate (/yr) 0.O00E+00 O.000E+00 R016 solubility constant 0.OO0E+O0 O.O00E+O0 R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 R017 Mass loading for inhalation (g/m**3) 1.000E-04 1.000E-04 R017 Exposure duration 3.000E+01 3.OOOE+01 RO17 Shielding factor, inhalation 5.500E-01 4.OOOE-01 RO17 shielding factor, external, gamma 2.725E-01 7.OOOE-01 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 RO17 shape factor flag, external gamma 1.000E+00 1.00OE+00 R017 Radii of shape factor array (used if FS = -1):
R0ll Outer annular radius (m), ring 1:
3 not used S.OOOE+0l RO17 Outer annular radius (i), ring 2:
not used 7.071E+01 R017 Outer annular radius (m),
ring 3:
not used 7.OOOE+0O RO17 Outer annular radius (m),
ring 4:
not used O.000E+O0 ROl7 Outer annular radius (m),
ring 5:
not used O.O00E+00 ROl7 Outer annular radius (m), ring 6:
not used O.O0OE+O0 R017 Outer annular radius (mi, ring 7:
not used 0.OOOE+0O RO17 Outer annular radius (i), ring 8:
not used O.OOOE+0O R017 Outer annular radius (m),
ring 9:
not used O.0OOE+00 R017 Outer annular radius (m),
ring 10:
not used O.OOOE+00 R017 Outer annular radius (m),
ring 11:
not used 0.OOOE+03 RO17 Outer annular radius (m),
ring 12:
not used O.00OE+0O IRESRAD, Version 6.5 Tx Limit = 30 days 11/28/2011 10:36 Page 5
Summary: HB sensitivity analysis.soil.sr-90 File
- C:RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\SR90 DCGL\\HB SOIL DCGLSR90.RAD used by RESRAD Parameter different from user input)
Name NS
-- H(1) 3 DENSUZ(1) 3 TPUZ(1) 3 EPUZ(1)
FCUZ(l)
-- BUZ(1)
-- HCUZ(1)
DCNUCC(
1) 3 DCNUCU( 1,1)
DCNUCS(
1) 2.830E-03 ALEACH(
1) not used SOLUBK(
1)
INHALR
-- MLINH 3 ED SHF3 SHF1 3-FIND
>0 shows circular AREA.
FS PADSHAPE(
1)
ADSHAPE(
2)
ADSHAPE(
3) 3-PADSHAPE(
4) 3-RADSHAPE(
5) 3-RAD_SHAPE(
6) 3-RADSHAPE(
7) 3-RADSHAPE(
8) 3-RADSHAPE(
9)
RADSHAPE(IO)
RADSHAPE(11) 3-RADSHAPE(12)
~ 13 0
3 Menu Paaee ROl7 3 Fractions of annular areas within RO17 Ring 1
R017 Ring 2
R017 Ring 3
R017 Ring 4
R017 Ring 5
R017 Ring 6
RO17 Ring 7
R017 Ring 8
R017 Ring 9
RO17 Ring 10 R017 Ring 11 R017 Ring 12 R018 Fruits, vegetables and grain consur R018 Leafy vegetable consumption (kg/yr)
R018 Milk consumption (L/yr)
R018 Meat and poultry consumption (kg/yi R018 Fish consumption (kg/yr)
R018 other seafood consumption (kg/yr)
R018 soil ingestion rate (g/yr)
R018 Drinking water intake (L/yr)
R018 Contamination fraction of drinkin R018 Contamination fraction of househod R018 Contamination fraction of livestoci R018 Contamination fraction of irrigati R018 Contamination fraction of aquatic R018 Contamination fraction of plant fo R018 Contamination fraction of meat R018 Contamination fraction of milk R019 Livestock fodder intake for meat (k R019 Livestock fodder intake for milk (k R019 Livestock water intake for meat (L/
R019 Livestock water intake for milk (L, R019 Livestock soil intake (kg/day)
R019 Mass loading for foliar deposition R019 Depth of soil mixing layer (m)
R019 Depth of roots (m)
R019 Drinking water fraction from ground R019 Household water fraction from grou R019 Livestock water fraction from groui R019 Irrigation fraction from ground war R19B Wet weight crop yield for Non-Leaf' R19B Wet weight crop yield for Leafy R19B Wet weight crop yield for Fodder R19B Growing season for Non-Leafy (yea R19B Growing Season for Leafy (yea tBARTLETT Site-Specific Parameter summary (continued)
User 3
used by RESRAD Input Default (if different from user input)
X....
Xi.S k.. a
..i. s a AREA:
not used 1.000E+O0 not used 2.732E-01 not used O.OOOE+O0 not used 0.OOOE+00 not used 0OOOE+O0 not used O.OOOE+O0 not used 0.000E+00 not used O.000E+00 not used 0.00 0
not used 03.OOOE+o0 not used O.0006E+00 not used 0.000E+00 0
mption (kg/yr) 1.120E+02 1.600E+02 2.140E+01 1.400E+01 3 2.330E+02 9.200E+01 r) 6.510E+01 6.300E+01 2.060E+01 5.400E+00 9.000E-01 9.000E-01 1.826E+01 a 3.650E+01 4.785E+02 5.100E+02 water 1.000E+00 1.000E+O0 0
d water not used 1.000E+00 k water 1.000E+O0 1.000+0 on water 1.000E+00 1.0006E+00 food 1.000E+00 5.OOOE-01 od
' 1.000E+00 '-1 3 1.000E+00 '-1 3
1.000E+00 :-1 kg/day) 2.710E+01 6.800E+01 kg/day) 6.320E+01 5.500E+01
/day) 5.060E+01 5.000E+01
/day) 6.OOOE+01 1.600E+02 S.OOE-01 5.000E-01 (g/m**3) 4.000E-04 1.000E-04 2.300E-01 1.500E-01 1.220E+00 9.000E-01 3 d water 1.000E+00 1.O00E+O00 nd water not used 1.000E+00 nd water 1.000E+00 31.000E+0 ter 1.000E+00 3.O00E+00 y (kg/m**2) 1.750E+00 7.000E-01 (kg/m**2) 2.889E+00 1.500E+O0 0
(kg/m*2) 1.887E+00 l.IOOE+00 rs) 2.460E-01 1.700E-01 rs) 1.230E-01 2.500E-01 Parameter Name FRACA( 1)
FRACA( 2)
FRACA( 3)
FRACA( 4)
FRACA( 5)
FRACA( 6)
FRACA( 7)
FRACA( 8) 3 FRACA( 9)
FRACA(10)
FRACA(11)
FRACA(12)
DIET(1)
DIET(2)
DIET(3)
DIET(4)
DIET(S)
DIET(6)
SOIL DWI FDW FHHW FLW 3 FIRW 3 FR9 3 FPLANT SFMEAT FMILK 3 LFI5 3 LFI6 LWIS LWI6 LSI 3 MLFD 3 DM DROOT FGWDW FGWHH FGWLW FGWIR YV(1)
YV(2)
YV(3)
TE(1)
TE(2)
NAA Page 125
Bartlett Engineering ENG-HB-003 Humboldt Bay Soil DCGLs Rev. 0 R19B 3 Growing Season for Fodder (years)
' 8.200E 8.OOOE-02 3 TE(3)
- 1RESRAD, Version 6.5 T<m Limit = 30 days 11/28/2011 10:36 Page 6
Summary HB sensitivity analysis.soils.r-90 File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\SR90 DCGL\\HB SOIL DCGL_.SR90.RAD Site-Specific Parameter Summary (continued) 0 3
User 3.
Used by RESRAD 3
Parameter Menu I Parameter.
.Input
'Default (If different from user input)
NI ame R19B Translocation Factor for Non-Leafy 1.000E-01 1.OOOE-01 TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.OOOE+00 TIV(2)
R19i Translocation Factor for Fodder 1.00OE+00 1.OOOE+00 TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.SOOE-01 2.SOOE-01 RDRY(1)
RI9B Dry Foliar Interception Fraction for Leafy 3.500E-01I 2.500E-01 RDRY(2)
RI9B Dry Foliar Interception Fraction for Fodder I3.500E-01 2.500E-01 RDRY(3)
R19i Wet Foliar Interception Fraction for Non-Leafy 3.5OOE-01 ' 2.500E-01 RWET(1)
Ri9B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 RWET(2)
RI9B Wet Foliar Interception Fraction for Fodder 3.50OE-01 2.500E-01 RWET(3)
R19B weathering Removal Constant for Vegetation 3.300E+01 2.000E+01 WLAM C14 C-12 concentration in water (g/cm**3) not used 2.OOOE-05 C12WTrR C14 C-12 concentration in contaminated soil (g/g) not used 3.OOOE-02 C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000-01 DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000-E07 EVSN C14 C-12 evasion flux rate from soil (1/set) not used 1.000E-10 REVSN C14 Fraction of grain in beef cattle feed not used 8.000~-01 AVFG4 C14 Fraction of grain in milk cow feed not used 2.OOO-E01 AVFG5 STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 STORT(1)
STOR Leafy vegetables 1.000E+O0 1.OOOE+00 STOR-T(2)
STOR Milk I.O00E+00 1.OOOE+00 STORT(3)
STOR Meat and poultry 2.OOOE+01 2.OOOE+01 STORT(4)
STOR Fish 7.OOOE+00 7.OOOE+00 STOR-T(S)
STOR Crustacea and mollusks 7.OO0E+00 7.OOOE+00 STORT(6)
STOR well water 1.000E+00 1.O00E+O0 STORT(7)
STOR surface water 1.O00E+00 1.O00E+00 STOLT(8)
STOR Livestock fodder 4.500E+01 4.500E+01 STORT(9)
R021 Thickness of building foundation (m) not used 1.500E-01 FLOOR1 R021 3 Bulk density of building foundation (g/cm**3) not used 2.400E+00 DENSFL R021 Total porosity of the cover material not used 4.OOOE-O1 TPCV R021 Total porosity of the building foundation not used 1.000E-01I TPFL R021 Volumetric water content of the cover material not used 5.000E-02 PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 OIFCV R021 in foundation material not used 3.OOOE-07 DIFFL R021 3 in contaminated zone soil not used 2.OOOE-06 DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.O0E+00 HMIX R021 Average building air exchange rate (1/hr) not used S.OOOE-01 I REXG R021 Height of the building (room)
(m) not used 2.500E+00 HRM R021 Building interior area factor not used 0.0000E+0 FAI R021 Building depth below ground surface (i) not used 3-1.000E+00 DMFL R021 Emanating power of Rn-222 gas not used 3 2.500E-01 EMANA(1)
R021 3 Emanating power of Rn-220 gas not used 3 1.5iOE-01 EMANA(2)
TITL Number of graphical time points 32
-PTS 1RESRAD, Version 6.5 T<" Limit ý 30 days 11/28/2011 10:36 Page 7
Summary : HB sensitivity analysis.soil.Sr-90 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\SR90 DCGL\\HB SOIL DCGL_SR90.RAD Site-Specific Parameter Summary (continued) 0 3
User 3
ffused by RESRAD 3 Parameter Menu.
Parameter
.input 3.Default
'.(If dierent from user input) 3 Name TITL ' Maximum number of integration points for dose 3
17
' LYMAX TITL ' Maximum number of integration points for risk 1
3 7
KYMAX itIi+/-tt+/-Iiltt11It+/-i+/-+/-+/-1+/-iff1313tt+/-
31 fItftt+/-1111flt1113i+/-fIii+/-ttt iittt+/-It+/-Iittt+/-+/-t31t*tIftIIIt it+/-Ift Itt+/-+/-+/- tt133tt11 Summary of Pathway Selections
.Pathway User Selection i...
1-- external gamma active 2
inhalation (w/o radon) 3 active 3 -- plant ingestion active 4-- meat ingestion active 5
milk ingestion active 6
aquatic foods active 7
drinking water active 8
soil ingestion active 9 --
radon suppressed Find peak pathway doses 3
active 1RESRAD, version 6.5 Tm, Limit = 30 days 11/28/2011 10:36 Page 8
Summary HB sensitivity analysis.soilSr-90 File
- C:\\RESRAD.FAMILY\\RESRAD\\6.5\\USERFILES\\SR90 DCGL\\HB SOIL DCGLSR90.RAD Contaminated Zone Dimensions Initial Soil Concentrations-p.Ci/9 a....
..............~...............................
i..
Area:
30000.00 square meters Sr-90 1.OOOE+00 Thickness:
2.67 meters Cover Depth:
0.00 meters 1RESRAD, Version 6.5 T-Limit = 30 days 11/28/2011 10:36 Page 1
Probabilistic results summary : HB sensitivity analysis-soil.Sr-90 File : C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\SR90 DCGL\\HB SOIL DCGLSR90.RAD Table of Contents Part VI: Uncertainty Analysis titttttftiftfit/tittiftttttt ORESRAD Uncertainty Analysis Results Probabilistic Input..
2 Total Dose...
3 eYARTLEf Page 126
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Total Risk...
4 Dose vs Pathway:
Ground External...................
5 Dose vs Pathway:
Inhalation (w/o Radon) 6 Dose vs Pathway:
Radon (Water Ind.)
7 Dose vs Pathway:
Plant (Water Ind.)
8 Dose vs Pathway:
Meat (Water Ind.)................
9 Dose vs Pathway:
Milk (water Ind.)................
10 Dose vs Pathway:
Soil Ingestion.....................
11 Dose vs Pathway:
Water Ingestion....................
12 Dose vs Pathway:
Fish Ingestion.....................
13 Dose vs Pathway:
Radon (Water Dep.)
14 Dose vs Pathway:
Plant (Water Dep.)
15 Dose vs Pathway:
Meat (Water Dep.)
16 Dose vs Pathway:
Milk (Water Dep.)
17 Cumulative Probability Summary.......................
18 Summary of dose at graphical 'times, reptition 1.....
19 Peak of the mean dose at graphical times.............
20 Correlation and Regression coefficients (if any)...
21 1RESRAD, version 6.5 T'c Limit = 30 days 11/28/2011 10:36 Page 2
Probabilistic results summary : HB sensitivity analysis.soilSr-90 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\SR90 DCGL\\HB SOIL DCGLSR90.RAD Probabilistic Input ONumber of Sample Runs: 2000 Number 1
2 3
45 6
7 8
9 10 11 12 13 14 15 16 17 18 19 20
.00003 21 22 23 24 25 26 27 28 29 30 31 32 f13131 Name DENSCZ TPCZ HCCZ BCZ EVAPTR RI DENSAQ TPSZ EPSZ HCSZ BSZ DWIBWT UW N(1)
DENSUZ(1)
TPUZ(1)
EPUZ(1)
HCUZ(1)
BUZ(1)
MLINH
.8119 SHF3 SHF1 DM Yv(1)
WLAM RWET(2)
DCACTC(1)
DCACTUI(1)
DCACTS(1)
BRTF(38,2)
BRTF(38,3)
BBIO(38,1)
Distribution Parameters BOUNDED NORMAL 1.5635
.2385
.827 2.3 BOUNDED NORMAL
.41
.09
.1319
.6881 BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 UNIFORM
.5
.75 UNIFORM
.36
.76 BOUNDED NORMAL 1.5105
.1855
.937 2.084 BOUNDED NORMAL
.43
.0699
.214
.646 BOUNDED NORMAL
.342
.0705
.124
.56 BOUNDED LOGNORMAL-N.362 1.59
.0106 195 BOUNDED LOGNORMAL-N 1.96
.265 3.02 15.5 TRIANGULAR 6
10 30 UNIFORM 1173 1973 UNIFORM 0
8.08 BOUNDED NORMAL 1.5635
.2385
.827 2.3 BOUNDED NORMAL
.41
.09
.1319
.6881 BOUNDED NORMAL
.315
.0905
.0349
.594 BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 CONTINUOUS LINEAR 8
0 0
.000008
.00004
.9495
.00006
.9937
.000076
.9983
.0001 1
UNIFORM
.15
.95 BOUNDED LOGNORMAL-N -1.3
.59
.044 1
TRIANGULAR 0
.15
.6 TRUNCATED LOGNORMAL-N.56
.48
.001
.999 TRIANGULAR 5.1 18 84 TRIANGULAR
.06
.67
.95 TRUNCATED LOGNORMAL-N 3.45 2.12
.001
.999 TRUNCATED LOGNORMAL-N 3.45 2.12
.001
.999 TRUNCATED LOGNORMAL-N 3.45 2.12
.001
.999 TRUNCATED LOGNORMAL-N -4.61
.4
.001
.999 TRUNCATED LOGNORMAL-N -6.21
.5
.001
.999 LOGNORMAL-N 4.1 1.1 11111111fif f ftftiffiffifLGiNRiMA-4.f1 1.1111111111111111111111111111 0151
.000016
.1365 IRESRAD, Version 6.5 T" Limit = 30 days 11/28/2011 10:36 Page 20 Probabilistic results summary : H1 sensitivity analysis.soilSr-90 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\SR90 DCGL\\HB SOIL DCGL.SR90.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1
0.000E+00 1.655E+01 t
DARTLETT Page 127
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Tc-99 Results:
1RESRAD, Version 6.5 Ta Limit = 30 days 11/28/2011 10:41 Page 1
Summary : HB sensitivity analysis.soilTc-99 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\TC99 DCGL\\HB SOIL DCGL_TC99.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary...
2 Site-Specific Parameter Summary............................
3 Summary of Pathway Selections..............................
7 Contaminated Zone and Total Dose Summary..................
8 Total Dose Components Time = O.OOOE+O0..
9 Time = 1.000E+00.....................................
10 Time = 3.OOOE+00.....................................
11 Time = 1.OOOE+01.....................................
12 Time = 3.OOOE+01.....................................
13 Time = I.OOOE+02..
14 Time = 3.000E+02..
15 Time = 1.OOOE+03....................................
16 Dose/Source Ratios Summed Over All Pathways 17 Single Radionuclide Soil Guidelines.......................
17 Dose Per Nuclide Summed Over All Pathways.................
18 Soil Concentration Per Nuclide.....................
18 IRESRAD, Version 6.5 T ` Limit = 30 days ii/28/2011 10:41 Page 2
Summary HB sensitivity analysis.soiljTc-99 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\TC99 DCGL\\HB SOIL DCGLTC99.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: HB DCGLS Plus FGR 12 & FGR 11 0
3 a Current I
Base a Parameter Menu Paaee Value# 3 Caset Name A-1 DCF's for external ground radiation, (mrem/yr)/(pCi/g)
A-I TC-99 (Source:
FGR 12) 1.255E-04 1.255E-04 DCF1(
1)
B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 TC-99 8.320E-06 8.320E-06 DCF2(
1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 TC-99 1.460E-06 1.460E-06 DCF3(
1)
D-34 Food transfer factors:
D-34 ITC-99
, plant/soil concentration ratio, dimensionless 9.160E+00 5.000E+00 RTF(
1,1)
D-34 TC-99 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.0003-04 1.000E-04 RTF(
1,2)
D-34 3cTc-99 milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.000E-03 1.000E-03 RTF(
1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Tc-99
, fish 2.000E+01 2.000E+01 a BIOFAC(
1,1)
D-5 TC-99 crustacea and mollusks 5.O00E+00 5.OOOE+00 a BIOFAC(
1 2)
- For DCF1(mxx) only, factors are for infinite depth & area.
See ETFG table in Ground Pathway of Detailed Report.
- Base Case means Default.Lib w/o Associate Nuclide contributions.
IRESRAD, Version 6.5 Tm Limit = 30 days 11/28/2011 10:41 Page 3
Summary : HB sensitivity analysis.soilTc-99 File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\TC99 DCGL\\HB SOIL DCGL.TC99.RAD Site-Specific Parameter Summary 0
3 User 3
a used by RESRAD Menu Parameter Input a Default (If different from user input)
Parameter Name ROll Area of contaminated zone (m**2)
ROll Thickness of contaminated zone (m)
R011 Fraction of contamination that is submerged R011 Length parallel to aquifer flow (m)
R011 Basic radiation dose limit (mrem/yr)
R011 Time since placement of material (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
Roll Times for calculations (yr)
Roll Times for calculations (yr)
Roll Times for calculations (yr)
Roll Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R012 Initial principal radionuclide (pCi/g):
TC-99 R012 Concentration in groundwater (pCi/L):
Tc-99 R013 Cover depth (m)
R013 Density of cover material (g/cm**3)
R013 Cover depth erosion rate (m/yr)
R013 Density of contaminated zone (g/cm**3)
R013 Contaminated zone erosion rate (m/yr)
R013 Contaminated zone total porosity R013 Contaminated zone field capacity R013 Contaminated zone hydraulic conductivity (m/yr)
R013 Contaminated zone b parameter R013 Average annual wind speed (m/sec)
R013 Humidity in air (g/m**3)
R013 Evapotranspiration coefficient R013 a Precipitation (m/yr)
R013 Irrigation (m/yr)
R013 a Irrigation mode R013 Runoff coefficient R013 watershed area for nearby stream or pond (m**2)
R013 Accuracy for water/soil computations R014 Density of saturated zone (g/cm**3)
R014 Saturated zone total porosity R014 Saturated zone effective porosity R014 Saturated zone field capacity R014 a Saturated zone hydraulic conductivity (m/yr) t OARTLETT a AREA 3.OOOE+041.0006+04 2.670E+00 a 2.000E+00 O.OOOE+00 O.000E+00 1.950E+02 1.000E+02 2.500E+01 3.000E+01 O.O00E+00 O.000E+00 1.000E+00 1.000E+00 3.000E+00 3.000E+00 1.O00E+01 1.000E+01 3.000E+01 3.000E+01 1.000E+02 1.000E+02 3.000E+02 3.000E+02 1.O00E+03 1.000E+03 not used O.000E+00 not used O.O00E+00 1.000E+00 OO00E+00 not used O.000E+00 0.000E+00 0.000E+00 not used 1.500E+00 not used I1.000E-03 1.564E+00 1.500E+00 2.200E-03 1.000E-03 4.100E-01 4.000E-01 9.500E-02 2.000E-01 3.900E+00 31.000E+01 S.600E+00 5.300E+00 3.040E+00 2.000E+00 not used 8.O00E+00 6.250E-01 5.000E-01 9.100E-01 1.000E+00 5.600E-01 2.000E-01 overhead overhead 5.000E-01 2.000E-01 2.520E+07 1.000E+06 1.000E-03 1.000E-03 1.510E+00 1.500E+00 4.300E-01 4.000E-01 3.420E-01 2.000E-01 8.800E-02 a 2.000E-01 2.880E+01 1.000E+02 AREA THICKO SUBMFRACT LCZPAQ BRDL TI T( 2)
T( 3)
T( 4)
T(
5)
T( 6) 3 T(
7) 1 T(
8) 3 T(
9)
T(10)
- S1(1) aw1l( 1)
COVERO DENSCV VCV DENSCZ VCZ TPCZ FCCZ 3HCCZ BCZ WIND HUMID EVAPTR PRECIP RI IDITCH RUNOFF WAREA EPS DENSAQ TPSZ EPSZ FCSZ HCSZ Page 128 Page 128
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 R014 I Saturated zone hydraulic gradient 2.000E-03 2.000E-02 R014 3 Saturated zone b parameter 7.100E+00 5.300E+00 R014 3 water table drop rate (m/yr) 1.000E-03 1.000E-03 R014 3 Well pump intake depth (m below water table) 1.000E+01 1.O00E+01 R014 Model: Nondispersion (No) or Mass-Balance (MB)
NO
' ND R014 Well pumping rate (m**3/yr) a 1.573E+03 2.500E+02 IRESRAD, version 6.5 Tv Limit - 30 days 11/28/2011 10:41 Page 4
Summary : HB sensitivity analysis.soil.Tc-99 File
- C:\\RESRADrFAMILY\\RESRAD\\6.5\\USERFILES\\TC99 DCGL\\HB SOIL DCGLTC99.RAD site-specific Parameter Summary (continued) 0 3
User 3
Menu 3Parameter 3
Input
'Default 3(if ROIS Number of unsaturated zone strata 1
3 1 R01S Unsat. zone 1, thickness (m) 4.040E+00 4.000E+00 R015 Unsat. zone 1, soil density (g/cm**3) 1.564E+00 1.500E+00 ROS Unsat. zone 1, total porosity 4.100E-01 4.00OE-01 R0IS Unsat, zone 1, effective porosity 3.150E-01I 2.OOOE-01 R015 Unsat. zone 1, field capacity 9.500E-02 2.00OE-01 R015 Unsat. zone 1, soil-specific b parameter 5.600E+00 5.300E+00 ROS3 Unsat. zone 1, hydraulic conductivity (m/yr) 3.900E+00 1.000E+01 RO6 Distribution coefficients for TC-99 RO16 Contaminated zone (cm**3/g) 4.280E+00 0.000E+00 RO16 unsaturated zone 1 (cm**3/g) 5.100E-01 0.O00E+00 R016 Saturated zone (cm**3/g) 5.100E-01 O.000E+00 R016 Leach rate (/yr)
O.000E+00 O.O00E+00 ROI6 Solubility constant O.0006+00 O.O00E+00 R017 Inhalation rate (m t *3/yr) 8.400E+03 I 8.400E+03 R017 Mass loading for inhalation (g/m**3) 1.000E-04 1.000E-04 R017 Exposure duration 3.OOOE+01 3.OOOE+01 R017 Shielding factor, inhalation 5.500E-01 4.000E-01 R017 Shielding factor, external gamma 2.725E-01 7.OOOE-01 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 R017 Shape factor flag, external gamma 1.000E+00 1.OOOE+0O R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m),
ring 1:
not used 5.O00E+01 R017 Outer annular radius (m),
ring 2:
not used 3 7.071E+01 R017 Outer annular radius (m),
ring 3:
not used O.000E+00 R017 Outer annular radius (m),
ring 4:
not used O.00E++/-00 R017 Outer annular radius (m),
ring 5:
not used O.000E+00 ROll Outer annular radius (m),
ring 6:
not used O.0000E+0 R017 Outer annular radius (m),
ring 7:
not used O.OOOE+00 R017 Outer annular radius (m),
ring 8:
not used O.000E+00 R017 Outer annular radius (m), ring 9:
not used 0.000E+00 R017 Outer annular radius (m), ring 10:
not used 0.O000E+00 R017 Outer annular radius (m), ring 11:
not used 0.OOOE+-O0 R017 Outer annular radius (m), ring 12:
not used 0.000E+00 IRESRAD, Version 6.5 7T" Limit = 30 days 11/28/2011 10:41 Page 5
Summary : HB sensitivity analysis.soilTc-99 File
- C:\\RESRADFAMILY\\RESBAD\\6.5\\USERFILES\\TC99 DCGL\\HB SOIL DCGLTC99.RAD Site-Specific Parameter Summary (continued) 0 3
User 1
3 menu Parameter 3
input Default (f
R017 Fractions of annular areas within AREA:
R017 Ring 1
not used 1.OOOE+00 R017 Ring 2
not used 2.732E-01 ROl7 Ring 3
not used O.000E+00 R017 Ring 4
not used O.O00E+00 R017 Ring 5
not used O.O00E+00 R017 Ring 6
not used O.O00E+00 R017 Ring 7
not used O.OOOE+00 R017 Ring 8
not used O.O00E+00 R017 Ring 9
not used O.000E+00 R017 Ring 10 not used O.000E+00 R017 Ring 11 not used O.O00E+00 R017 Ring 12 not used O.000E+00 RO8 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 RO8 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 RO8 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 ROl8 Fish consumption (kg/yr) 2.060E+01 5.400E+00 R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 ROI8 Drinking water intake (L/yr) 4.785E+02 5.100E+02 R018 contamination fraction of drinking water 1.000E+00 1.000E+00 R018 Contamination fraction of household water not used 1.000E+00 R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 RO18 Contamination fraction of irrigation water 31.000E+00 31.000E+00 RO18 Contamination fraction of aquatic food 1.O00E+00 5.O00E-01 R018 Contamination fraction of plant food 1.000E+00 3-1 R018 Contamination fraction of meat 1.000E+00 '-1 R018 Contamination fraction of milk 1.000E+00 :-1 R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 R019 Livestock water. intake for meat (L/day) 5.060E+01 a 5.OOOE+01 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 R019 Livestock soil intake (kg/day) 5.000E-01 S.O00E-01 R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 R019 Depth of soil mixing layer (m) 2.300E-01 I1.500E-01I R019 Depth of roots (m) 1.220E+00 9.000E-01 R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 R019 Household water fraction from ground water not used 1.000E+00 R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 R19B Wet weight crop yield for Non-Leafy (kg/m"*2) 1.750E+00 7.000E-01 R19B wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 R19B wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02
' BA RT L ETT I HGWT 3 BSZ 3 DWIBWT
-MODEL used by RESRAD Parameter different from user input)
Name
~AAAAAAAA~aaAAAAAAA~pAAAAAA
-NS
-H(1)
-- DENSUZ(1) 3 TPUZ(1) 3 EPUZ(1)
FCUZ(1)
-- BUZ(1)
HCUZ(1)
-- DCNUCC( 1)
DCNUCU( 1,I)
-- DCNUCS( 1) 2.025E-02 ALEACH( 1) not used SOLUBK( 1)
-- INHALR
-- MLINH
- -ED 3 SHF3 3 SHF1 FIND 3 FOTD 0 shows circular AREA.
FS RADSHAPE(
1) 3 BADSHAPE(
2) 3 PAD.SHAPE(
3)
-- RADSHAPE( 4) 3 RADSHAPE(
5) 3 RADSHAPE(
6)
-- RADSHAPE(
7) 3 RADSHAPE(
8) 3 RADSHAPE(
9)
--- RADSHAPE(10) 3 RADSHAPE(11)
-RADSHAPE(12) used by RESRAD different from user 3 Parameter input)
Name FRACA( 1)
FBACA( 2)
FRACA( 3)
FBACA( 4)
FRACA( 5)
FRACA( 6)
FRACA( 7)
FRACA( 8)
FRACA( 9)
FRACA(10)
FRACA(l1)
FRACA(12) 3 DIET(1)
DIET(2)
DIET(3) 3 DIET(4)
DIET(S)
DIET(6)
SOIL IDWI 3 FDW 3FHHW FLW FIRW FR9 FPLANT FMEAT FMILK LFI5 3 LFI6 3LW1 5 3 LWI6 LSI MLFD 3 DM DROOT FGWDW FGW/HB FGWLW FGWIR Yv(1)
YV(2)
YV(3)
TE(1)
TE(2)
TE(1)
Page 129
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 IRESRAD, Version 6.5 T<( Limit = 30 days 11/28/2011 10:41 Page 6
Summary HB sensitivity analysis.soil_Tc-99 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\TC99 DCGL\\HB SOIL DCGLTC99.RAD 0
menu 3Parameter R19B Translocation Factor for Non-Leaf R19B Translocation Factor for Leafy R19B Translocation Factor for Fodder R19i Dry Foliar Interception Fraction f RI9B Dry Foliar Interception Fraction f R19B Dry Foliar Interception Fraction f R19B I Wet Foliar Interception Fraction f R19B Wet Foliar Interception Fraction f RIeB 3 Wet Foliar Interception Fraction f Ri9B weathering Removal Constant for Ve c14 C-12 concentration in water (g/cm*
C14 C-12 concentration in contaminated C14 Fraction of vegetation carbon from C14 Fraction of vegetation carbon from C14 C-14 evasion layer thickness in so C14 C-14 evasion flux rate from soil C14 C-12 evasion flux rate from soil C14 3 Fraction of grain in beef cattle f C14 Fraction of grain in milk cow feed STOR Storage times of contaminated food STOR Fruits, non-leafy vegetables, an STOR Leafy vegetables STOR Milk STOR Meat and poultry STOR Fish STOR Crustacea and mollusks STOR Well water STOR Surface water STOR Livestock fodder R021 Thickness of building foundation R021 Bulk density of building foundatio R021 3 Total porosity of the cover materi R021 I Total porosity of the building fou R021 I volumetric water content of the cou R021 volumetric water content of the fo R021 Diffusion coefficient for radon ga R021 in cover material R021 I in foundation material R021 in contaminated zone soil R021 Radon vertical dimension of mixing R021 I Average building air exchange rate R021 Height of the building (room)
(m)
R021 Building interior area factor R021 Building depth below ground surfac R021 Emanating power of Rn-222 gas R021 Emanating power of Rn-220 gas Site-Specific Parameter Summary (continued)
User 3
used by RESRAD Parameter I. Input
- 3. Default I (if different from user.input) 3 Name y
1.000E-01 O1.O0E-01 TIV(1) 1.0OOE+00 1.OOOE+00 TIV(2) 1.000E+00 1.000E+00 TIV(3) or Non-Leafy 3.SOOE-01 2.500E-01 RDRY(1) or Leafy 3.500E-01 2.500E-01 RDRY(2) or Fodder 3.500E-01 2.500E-01 RDRY(3) or Non-Leafy 3.500E-01 2.500E-01 RWET(1) or Leafy S.800E-01 2.SOOE-01 RWET(2) or Fodder I 3.SOOt-01 2.5OOE-01 WLET(3) getation 3.300E+01 2.OOOE+01 WLAM
-3) not used 2.OOOE-05 C12WTR soil (g/g) not used 3.000E-02 cl2cz soil not used 2.000E-02 CSOIL air not used 9.800E-01 CAIR il (m) not used 3.000E-01 DMC 1/sec) 3 not used 7.OOOE-07 EVSN 1/sec) 3 not used 1.000E-10 REVSN eed not used 8.000E-01 I AVFG4 not used 2.OOOE-01 AVFG5 stuffs (days):
d grain 1.400E+01 1.400E+01 STOR-T(1) 1.O00E+00 1.OOOE+00 STOR_T(2) 1.OOOE+00 1.OOOE+00 STOLT(3) 2.000E+01 2.OOOE+01 STORT(4) 7.000E+00 7.OOOE+000 STOT(5) 7.OOOE+00 7.000E+00 STORT(6) 1.O00E+00 1.OO0E+0 STOR_T(7) 1.000E+00 1.OOOE+00 STOR_T(8) 4.500E+01 4.SOOE+01 STORT(9) m)
not used I 1.S00E-01 FLOOR1 n (g/cm**3) not used 2.400E+00 DENSFL al not used 4.OOOE-01 TPCV ndation not used 1.OOOE-01I TPFL ver material 3 not used S.OOOE-02 PH2OCV undation not used 3.OOOE-02 PH2OFL s (m/set):
not used 2.OOOE-06 DIFCV not used 3.OOOE-07 DIFFL not used 2.000E-06 DIFCZ (m) not used 2.OOOE+00 HMIX (1/hr) not used S.000E-01 REXG not used 2.S00E+00 HRM not used 0.OOOE+00 FAX e (m) not used 3-1.OOOE+00 DMFL not used I 2.5OOE-01 EMANA(1) not used I 1.500E-01 EMANA(2)
TITL Number of graphical time points 32 NPTS 1RESRAD, Version 6.5 T-Limit = 30 days 11/28/2011 10:41 Page 7
Summary : HB sensitivity analysis-soil-Tc-99 File
- C:\\RESRAD-FAMILY\\RESRAD\\6.5\\USERFILES\\TC99 DCGL\\HB SOIL DCGLTCS9.RAD site-Specific Parameter Summary (continued) 0 User used by RESRAD Parameter Menu Parameter Input.Defaun...............
lt (if differentDfrom user input)
Name TITL I Maximum number of integration points for dose 17 3
LYMAX TITL Maximum number of integration points for risk 1
KYMAX Summary of Pathway Selections
.Pathway user selection 1--
external gamma active 2
inhalation (w/o radon)'
active 3 -- plant ingestion active 4
meat ingestion active 5
milk ingestion active 6
aquatic foods active 7
drinking water active 8 --
soil ingestion active 9 --
radon suppressed Find peak pathway doses active IRESRAD, Version 6.S Tm Limit = 30 days 11/28/2011 10:41 Page 8
Summary : HB sensitivity analysis-soilTc-99 File
- C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\TC99 DCGL\\HB SOIL DCGL.TC99.RAD Contaminated Zone Dimensions Initial Soil Concentrations.Ci/9 Area:
30000.00 square meters Tc-99 1.000E+00 Thickness:
2.67 meters Cover Depth:
0.00 meters iRESRAD, Version 6.5 T, Limit = 30 days 11/28/2011 10:41 Page 1
Probabilistic results summary : HB sensitivity analysis.soilTc-99 File : C:\\RESRADFAMILY\\RESRAD\\6.S\\USERFILES\\TC99 DCGL\\HB SOIL DCGLTC99.RAD Table of Contents Part VI: Uncertainty Analysis ORESRAD Uncertainty Analysis Results Probabilistic Input.................................
. 2 Total Dose...
3 Total Risk...
4
()
Bartlett Engineering Humboldt Bay Soil DCGLs ENG-HB-003 Rev. 0 Dose vs Pathway:
Ground External...................
5 Dose vs Pathway:
Inhalation (w/o Radon)............
6 Dose vs Pathway:
Radon (Water Ind.)................
7 Dose vs Pathway:
Plant (Water Ind.)................
8 Dose vs Pathway:
Meat (Water Ind.)................
9 Dose vs Pathway:
Milk (water Ind.)................
10 Dose vs Pathway:
Soil Ingestion.....................
11 Dose vs Pathway:
Water Ingestion.....................
12 Dose vs Pathway:
Fish Ingestion...................
13 Dose vs Pathway:
Radon (water Dep.)................
14 Dose vs Pathway:
Plant (Water Dep.)................
15 Dose vs Pathway:
Meat (water Dep.)................
16 Dose vs Pathway:
Milk (water Dep.)
17 Cumulative Prohability Summary........................
18 Summary of dose at graphical times, reptition 1..
19 Peak of the mean dose at graphical times.............
20 Correlation and Regression coefficients (if any).....
21 IRESRAD, Version 6.5 Tc' Limit = 30 days 11/28/2011 10:41 Page 2
Probabilistic results summary : HB sensitivity analysis.soil_..Tc-99 File : C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\TC99 DCGL\\HB SOIL DCGLUTC99.RAD Probabilistic Input ONumber of Sample Runs: 2000 Number 1
23 45 6
7 8
9 10 11 12 13 14 1s 16 17 18 19 20
.00003 21 22 23 24 25 26 27 28 29 30 31 ttilti Name DENSCZ TPCZ HCCZ BCZ EVAPTR RI DENSAQ TPSZ EPSZ HCSZ BSZ DWIBWT UW H(1)
DENSUZ(1)
TPUZ(1)
EPUZ(1)
HCUZ(1)
BUZ(1)
MLINH
.8119 SHF3 SHF1 DM YV(1)
WLAM RWET(2)
DCACTU1(1)
DCACTS(1)
BRTF(43,2)
BRTF(43,3)
BBIO(43 1)
Distribution Parameters AAA.AXXAA W XXXXA XXXXXXXXXXXXXXXXA........
BOUNDED NORMAL 1.5635
.2385
.827 2.3 BOUNDED NORMAL
.41
.09
.1319
.6881 BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 BOUNDED LOGNORMAL-N 1.73
.323 2.08 15.3 UNIFORM
.5
.75 UNIFORM
.36
.76 BOUNDED NORMAL 1.5105
.1855
.937 2.084 BOUNDED NORMAL
.43
.0699
.214
.646 BOUNDED NORMAL
.342
.0705
.124
.56 BOUNDED LOGNORMAL-N.362 1.59
.0106 195 BOUNDED LOGNORMAL-N 1.96
.265 3.02 15.5 TRIANGULAR 6
10 30 UNIFORM 1173 1973 UNIFORM 0
8.08 BOUNDED NORMAL 1.5635
.2385
.827 2.3 BOUNDED NORMAL
.41
.09
.1319
.6881 BOUNDED NORMAL
.315
.0905
.0349
.594 BOUNDED LOGNORMAL-N 1.36 2.17
.00478 3190 BOUNDED LOGNORMAL-N 1.73
.323 2.08 1S.3 CONTINUOUS LINEAR 8
0 0
.000008
.00004
.9495
.00006
.9937
.000076
.9983
.0001 1
UNIFORM
.15
.95 BOUNDED LOGNORMAL-N -1.3
.59
.044 1
TRIANGULAR 0
.15
.6 TRUNCATED LOGNORMAL-N.56
.48
.001
.999 TRIANGULAR 5.1 18 84 TRIANGULAR
.06
.67
.95 TRUNCATED LOGNORMAL-N
-. 67 3.16
.001
.999 TRUNCATED LOGNORMAL-N
-. 67 3.16
.001
.999 TRUNCATED LOGNORMAL-N -9.21
.7
.001
.999 TRUNCATED LOGNORMAL-N -6.91
.7
.001
.999 LOGNORMAL-N 3
1.1 t*1tttttfff Ittttiffitftftitltifi11 tttiiffittttiffitfifilfffitffiff/tItttt 0151
.000016
.1365 IRESRAD, Version 6.5 Ta Limit = 30 days 11/28/2011 10:41 Page 20 Probabilistic results summary : HB sensitivity analysis.soilTc-99 File : C:\\RESRADOFAMILY\\RESRAD\\6.5\\USERFILES\\TC99 DCGL\\HB SOIL DCGLTC99.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1
0.OO0E+00 2.018E+00 t
BARTLETT Page 131