BHAP C-20.1 Rev. 8 Page 1 of 1 HUMBOLDT BAY POWER PLANT CALCULATION COVER SHEET Calculation No.:

GEO.HBIP.03.02 El Preliminary LS Final Department/Group:

BBPP/Geosciences Unit(s) 0 Structure, System or Component:

ISFSI Geotechnical Type or Purpose of Calculation:

Amplification Factors for Probabilistic Seismic Hazard Analysis at the HBIP ISFSI Site No. of Sheets:

349 incl Annendices Plant Problem Report No.

N/A Signature Discipline/Dept Date Prepared by:

By Geosciences Checked by:

By Geosciences AK Approved by (Supv):

08/28/2003 08/28/2003 10/02/2003 Registered Engineer Approval: (Complete secion A for Civil calcs. Complete A or B for others A. Insert Engineer Stamp or Seal Below B.

Engineer's full name:

By Geosciences Registration Number:

Expiration Date:

Expiration Date:

RECORDS OF REVISIONS Approval Revision Reasons for Revision & Plant Prepared Checked.

Regis. Engr.

Supvr.

Number Date Problem Report Number By By 0

09/29/03 Initial Issue Geosci.

Geosci.

Geosci.

a.

Pacific Gas and Electric Company Geosciences Department Calculation Document Calc Number:

GEO.HBIP.03.02 Calc Revision:

00 Calc Date:

08/27/03 Quality Related:

Ye S s-'A-p.

9j 1 -a ITR Verification Method:

A 5f4&Cr thJbA-

/ [-P ri Ktg M

A//'sI c

1.0 TITLE

Amplification Factors for Probabilistic Seismic Hazard Analysis at HBPP ISFSI Site 2.0 SIGNATORIES PREPARED BY:

g-

~

Date:

47b Q

Norman Abrahamson Printed Name Geosciences Organization VERIFIED BY:

wl Q427 (A4/

Date:

Joseph I. Sun Printed Name Date:

Printe Name

/1/

a3 Geosciences Organizati6h Organization APPROVED BY:

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 2 of 349 Date: 08/27/03 3.0 RECORD OF REVISIONS Rev.

Reason for Revision Revision No.

Date 00 Initial Calculation Document 08/27/03

.~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

.~~~~~~~~~~~~~~~~

I

_~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

.~~~~~~~~

I

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 3 of 349 Date: 08/27/03 Table of Contents

1.

Title Page I

2.

Signatories I

3.

Record of Revisions 2

4.

Purpose 4

5.

Assumptions 4

5.1 Spectral acceleration for very short periods 4

5.2 Empirical constraints on spectral content 4

5.3 Reasonableness of site response analysis using SHAKE 4

5.4 Earthquake time histories S

6.

Inputs 7

6.1 Rock Input Time Histories 7

6.2 Spectral shape of time histories from the Northridge earthquake S

6.3 Soil Response Spectra 9

7.

Methods and Equation Summary 94 7.1 Methods 94 7.2 Equations 95 7.2.1 Amplification factor 95

8.

Software 96 8.1 SPCTLR 96 8.2 SHAKE96 96 9

Body of Calculations 97 9.1 Compute rock spectra 97 9.2 Compute amplification factors 107 9.3 Select subset of spectral periods 135 10 Results and Conclusions 145 11 Limitations 160 12 Impact Evaluation 160 13 References 160 14 Enclosures and Attachments 161 Appendix A - Contents of CD ROM 162 Appendix B - Rock Time Histories 193

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 4 of 349 Date: 08/27/03

4. PURPOSE The purpose of this calculation is to develop a model of the frequency and amplitude dependent ground motion amplification induced by dynamic site response at the HBPP ISFSI site as part of AR A0583 100. The soil amplification factor model will be used in a probabilistic hazard calculation for HBIP.
5. ASSUMPTIONS 5.1 Spectral Accelerations for Very Short Spectral Periods The spectral acceleration at spectral periods less than 0.02 seconds period is assumed to be equivalent to peak ground acceleration. The basis for the assumption is that there is no significant energy above 50 Hz in soil site time histories (Abrahamson and Silva, 1997).

5.2 Empirical Constraints on the Spectral Content The equivalent linear site response method used in the SHAKE program tends to overdamp the high frequencies for large input motions such as those used for EBPP.

Large amplitude ground motions recorded during the Jan. 15, 1994 Northridge, CA earthquake on seven soil sites listed below are assumed to have similar high frequency spectral shapes to the site response at HBIP for large amplitude ground motions.

Table 5.1 Time histories used for constraining the high frequency spectral shape Stations PGA Rinaldi Receiving Station 0.84g Sepulveda VA 0.94g Sylmar Converter Station 0.90g Sylmar Converter Station east 0.83g Sylmar Olive View Free-Field

0. 84g Newhall Fire Station 0.59g Jensen Filtration Plant 0.59g The basis for this assumption is that the seven selected recordings are from soil sites with similar velocity profiles to the velocity profile at HBPP (see calc GEO.HBIP.02.06, rev 0, section 3.3 ) and the recorded peak accelerations at these stations are large. Given the high levels of ground motion and the similar velocity profile range, the high frequency spectral content is expected to be representative of the high frequency spectral shape at HBPP for large ground motions.

5.3 Reasonableness of Site Response Analysis Under High Ground Acceleration The SHAKE runs are assumed to give reasonable site amplification factors for input peak accelerations up to peak accelerations of 1.6g from earthquake magnitudes up to 7.8.

The basis for this assumption is the evaluation of the SHAKE runs at high input motions given in calculation GEO.HBIP.02.06 (section 7.1.4). In this previous evaluation,

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 5 of 349 Date: 08/27/03 GEO.HBIIP.02.06 concluded that the SHAKE96 computations were not breaking down with increasingly large levels of ground motion for peak rock accelerations up to 1.6g for magnitude 7.8 earthquakes.

5.4 Earthquake Time Histories for Site Response Analysis Using SHAKE Since the site response is only used to get amplification factors (expressed as spectral ratios between the computed surface motion with respect to the input motion), the results are not very sensitive to selection of the input time histories, so the choice of time histories is not critical as long as they have the appropriate spectral content.

For this calculation, site amplification factors are developed for M6, M7 and M7. 8 earthquakes. The time histories for M7.8 were described previously in GEO.HBIP.02.06 (section 3.3). For the M6 and M7 cases, the same approach was used to develop the time histories.

The spectrum compatible time histories listed in Table 5-2 below are assumed to be representative of rock ground motions from M=6 and M=7 earthquakes. The basis for this assumption is that initial time histories (Table 5-2) are within 0.3 magnitude units of the target value (e.g. the earthquake magnitude is reasonable) and the spectral shapes of the time histories (Figure 5-1) show a broad spectral content appropriate for M=6 and M=7 earthquakes. For comparison, the spectral shapes of the M7.8 time histories are also shown in Figure 5-1. These time histories are listed in Appendix B.

Table 5-2. Time Histories used in the site response analysis File Name Target Eqk Station Mag Mag M60SETI.acc 6.0 6.0 Whittier Eqk, LA Baldwin Hills M60SET2.acc 6.0 6.0 Whittier Eq,

.___-_____ :West Covina - S.

Orange M60SET3.acc 6.0 6.4 Coalinga Eqk, Parkfield - Vineyard Cyn M7OSET1.acc 7.0 6.7 Northridge, West Pico Cyn M70SET2.acc 7.0 6.9 Loma Prieta,

_L G P C M70SET3.acc 7.0 6.9 Loma Prieta, S arato g a

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 6 of 349 Date: 08/27/03 S-co Period (ec)

Figure 5-1. Spectral shapes of the input rock time histories.

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 7 of 349 Date: 08/27/03

6. INPUTS 6.1 Rock Input Time Histories The attachments (CD ROM) to Calculation GEO.HBIP.02.06 includes 3 sets of rock time histories that were used in the site response analysis for the M7.8 case. These three sets of time histories are listed in appendix A.

Table 6-1. File Names for the input rock time histories from Calculation GEO.HBIP.02.06 File Name Magnitude Set M7.8SETI.ACC 7.8 1

M7.8SET2.ACC 7.8 2

M7.8SET3.ACC 7.8 3

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 8 of 349 Date: 08/27/03 6.2 Spectral Shapes of Time Histories from the Northridge Earthquake The spectral shapes of the 14 Northridge time histories (7 stations listed in Assumption 3.2) are given in GEO.HBIP.02.06, (Table 7-25). The values are listed in Table 6-2.

Table 6-2. Average horizontal rock spectral shape based on 10 Northridge strong motion recordings.

Period Average (sec)

Spectral Shape 0.010.

1.0000 0.020 1.0063 0.030 1.0155 0.050 1.0945 0.075 1.2255 0.100 1.3835 0.150 1.6904 0.200 1.9114 0.300 2.3682 0.500 1.9805 0.750 2.0486 1.000 1.6823 1.500 1.0362 2.000 0.7649 3.000 0.4510 4.000 0.2081

... I

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 9 of 349 Date: 08/27/03 6.3 Soil Response Spectra Three alternative soil profiles were used in calculation GEO.HBIP.02.06: median, lower, and upper (see GEO.HBIP.02.06 section 4.1). The soil response spectra computed for each M7.8 input time history scaled to PGA values of 0. Ig up to 1.6g for each of the three soil profiles are given in the CD ROM attachment to Calculation GEO.HBIP.02.06. As part of the work for Calculation GEO.HBIP.02.06, the site response was computed for the other six sets of rock time histories (M6 and M7), but these results were not included in the CD ROM attached to Calculation GEO.HBIP.02.06. These additional calculations used the same soil profiles (Table 7-1 in Calc GEO.HBIP.02.06) and the same verified computer program (SHAKE96, section 6 in Calc GEO.HBIP.02.06).

The site response files for the additional magnitudes as well as for the M7.8 case are given in the CD ROM attachment to this calculation. The file names from the CD ROM are listed in Tables 6-3a,b,c. The naming convention for the directory name is as follows: the first two characters refers to the soil profile (ml =median profile, m2=lower profile, m3=upper profile); the next character is the time history index (I=M6.0 set 1, 2=M6.0 set 2, 3=M6.0 set3, 4=M7.0 set 1, 5=M7.0 set 2, 6=M7.0 set 3, 7=M7.8 set 1, 8=M7.8 set 2, and 9=M7.8 set 3). The naming convention for the files within a directory are as follows:

the first two characters are the same as the directory (eg. they indicate the soil profile).

The remaining characters indicate the input rock pga level in g with the "p" indicating a decimal point. For example, "mlp9g.out" corresponds to the median soil profile with the rock time history scaled to 0.9g.

The resulting soil response spectral values for these cases are listed in Tables 6-4 to 6-12.

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 10 of 349 Date: 08/27/03 Table 6-3a-File names for soil spectra for the median profile M

Soil Rock Set I Set 2 Set3 Profile PGA 69) 6.0 Median 0.1 mll runs/ml pig.out mI2 runs/ml I out ml3 runs/mi pitout 6.0 Median 0.2 ml Iruns/ml p2g.out m12 runs/ml p2g.out m13 runs/rml P22.out 6.0 Median 0.3 mu runsi p3g.out m12 runs/ml p3z.out m13 runs/ml p3g.out 6.0 Median 0.4 mil runs/ml p4g.out ml2 runs/mi p4.out ml3 uns/mi p4g.out 6.0 Median 0.5 ml l runsmil pig.out m12 runs/mil D~g.out m13 runs/ml p5g.out 6.0 Median 0.6 ml I runs/ml p6g.out m12 runs/ml p6g.out ml3 runs/ml p6g.out 6.0 Median 0.7 ml1 runs/ml p7g.out m12 runs/ml p7g.out ml3 runs/ml p7g.out 6.0 Median 0.8 mnlI runs/ml p8g.out m12 runs/ml p8g.out ml3 runs/ml p8g.out 6.0.

Median 0.9 ml I runs/ml p9g.out ml2 runs/ml p9g.out m13 runs/ml p9g.out 6.0 Median

.1.0 mu ru/mi IpOg9out ml2 runs/mI Ip0g.out ml3 runsrml IpOg.out 6.0 Median I,2 ml runs/ml Ip2g.out mi2 runs/mi Ip2g.out ml3 runs/ml Ip2g.out 6.0 Median 1.4 mul runs/ml Ip4g.out ml2 runs/ml Ip4g.out ml3 runs/ml Ip4g.out 6.0 Median 1.6 mlI runs/m I Ip6g.out m12 runs/ml Ip6g.out m13 runs/ml Ip6g.out 7.0 Median 0.1 ml4 runs/ml pig.out mil runs/mi pig.out ml6 runs/ml pi4.out 7.0 Median 0.2 ml4 runs/ml p2g.out mi5 runs/mI p2g.out ml6 runs/il p2g.out 7.0 Median 0.3 ml4 runs/ml p3g.out mi5 runs/ml p3g.out ml6 runs/ml p3g.out 7.0 Median 0.4 ml4 runs/ml p4g.out mi5 runs/ml p4g.out m16 runs/ml p4g.out 7.0 Median 0.5 m14 runs/ml p~gout mi5 runs/ml p5g.out ml6 runs/ml p5g.out 7.0 Median 0.6 ml4 runsm/l p6,.out ml5 runs/mil p6g.out m16 runmml p6g.out 7.0 Median 0.7 m14 runs/ml p7g.out ml5 runs/mil PR.out mi6 run/ml p7g.out 7.0 Median 0.6 ml4 runs/ml p~g.out mi5 runsIml pSg.out mI6 runs/ml p~g out 7.0 Median 0.9 ml4 runs/ml p9g.out mIl runs/m pg.

uns/m p9g.out 7.0 Median 1.0 mi4 runs/mi IpOg.out ml5 runsi IpOg.out ml6 runs/mi Ip~g.out 7.0 Median 1.2 ml4 runs/ml Ip2g.out mi5 runs/ml Ip2g.out ml6 runs/ml Ip2g.out 7.0 Median 1.4 mi4 runs/ml Ip4g.out ml5 runs/ml Ip4g.out ml6 runs/ml Ip4g.out 7.0 Median 1.6 m14 runs/ml Ip61.out mi5 runs/ml Ip6g.out ml6 runs/ml Ip6g.out 7.S Median 0.1 m1i runs/ml pig.out m1S runs/ml plg.out ml9 runs/mil pIgout 7.8 Median 0.2 mi1 runs/ml P2g.out miS runs/mi p2g.out ml9 rus/ml p2g.out 7.S Median 0.3 ml7 runs/ml p3g.out mlS runs/ml p3g.out m19 runs/ml p3g.out 7.8 Median 0.4 ml7 rus/mi p4g.out mlS runs/ml p4g.out ml9 runs/ml P4g.out 7.8 Median 0.5 ml7 runs/ml p5g.out mlS runs/mil pg.out m19 runs/ml pSg.out 7.8 Median 0.6 ml7 runs/mi p6.out mlS runsI/ml p6g.out mi9 runs/ml pdg.out 7.8 Median 0.74 m17 runs/ml pi7out mlS runs/ml p7g.out ml9 runs/mi P7e.out 7.8 Median 0.8 m17 runsmil p

~g.out m18 runs/mi p8g out m19 runinam p8g.out 7.8 Median 0.9 m17 runsIml p9g~out mlS runs/ml p9g.outn ml9 runs/ml p9gout 7.8 Median 1.0 ml7 runs/ml IpOgout mIS runs/ml IpOgout m19 runsml IpOg.out

' Median 1.2 m17 runs/ml Ip2g.out miS runs/ml Ip2g.out m19 runs/ml Ip2g.out 7.8

-Median 1.4 ml7 runs/ml Ip4g.out mlS runs/ml Ip4g.out ml9 runs/ml Ip4gout 7.8 Median 1.6 mi7 runs/ml Ip6g.out mIS runs/ml Ip6g.out ml9 runs/ml Ip6gout

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 1I of 349 Date: 08/27/03 Table 6-3b. File names for soil spectra for the lower profile M

Soil Rock Set I Set 2 Set 3 Profile PGA 6.0 Lower 0.1 m21 runs/m2 PIl.out m22 runs/m2 pigout m23 runs/m2 plg.out 6.0 Lower 0.2 m21 runs/m2 p2g.out n22 runs/m2 p2g~out m23 runs/m2 p2g.out 6.0 Lower 0.3 m21 runs/m2 p3e gout m22 runs/m2 p3g.out m23 runs/m2 D3z.out 6.0 Lower 0.4 m2i runs/m2 p4g.out mn22 runss/m2 p4g.out m23 runstm2 p4 out 6.0 Lower 0.5 m21 runs/m2 p5g.out m22 runs/m2 p5g.out m23 ruts.m2 p5g.out 0.5~~~~~

.out 6.0 Lower 0.6 m21 runs/m2 p6g.out ni22 runs/m2 p6g.out m23 runs/m2 p6g.out 6.0 Lower 0.7 m2l runs/m2 p7g.out m22 runs/m2 p7,e.out m23 runs/n2 p7g.out 6.0 Lower 0.8 m21 runs/m2 p8g.out m22 runsfm2 pRg.out I

m23 runstm2 p8g.out 6.0 Lower 0.9 m21 rans/m2 p9g.out m22 runs/m2 p9gout m23 rans/m2 p9g.out 6.0 Lower 1.0 m2l runstm2 IpOgout m22 runsrm2 IpOgout m23 runs/rn2 IpOgout 6.0 Lower 1.2 m21 runstm2 1p22.out m22 runs/ri2 1p2.out m23 runs/m2 lp2vout 6.0 Lower 1.4 m21 runs/mi2 p4g.out m22 runs/m2 lp4g.out m23 runs/m2 lp4g.out 6.0 Lower 1.6 m21 runsto l2ID6out m22 runs/rm2 1p6g.out m23 runs/m2 lp6g out 7.0 Lower 0.1 m24 runstm2 plg.out m25 runs/m2 p1g out m26 runs/m2 plg.out 7.0 Lower 0.2 m24 runs/n2 p2g.out m25 runs/m2 p2g.out m26 runs/m2 P29-out 7.0 Lower 0.3 m24 runs/m2 p3g.out m25 runs/m2 p3g.out rn26 runstm2 p3g.out 7.0 Lower 0.4 m24 nrns/m2 p4geout rn25 runs/m2 p4g.out m26 runs/rM2 p4g.out 7.0 Lower 0.5 m24 runs/m2 p5g.out m25 runs/m2 p5g.out m26 nsns/m2 S5Qout 7.0 Lower 0.6 m24 runs/m2 p6e.out m25 ruuns/m2 p6g~out m26 runs/m2 p6g.out 7.0 Lower 0.7 m24 runs/tn2 p7g.out m25 runs/m2 p7g.out m26 runstm2 p7g.out 7.0 Lower 0.8 m24 nruns/m pg.out m25 runs/m2 p8g.out m26 runs/m2 p8gout 7.0 Lower 0.9 m24 runs/m2 p9t.out m25 ranstm2 p9e.out m26 runs/mn2 p9gout 7.0 Lower 1.0 rn24 runs/m2 IpO,.out mn25 runsmi2 IpOg.out m26 runs/m2 IpOg.out 7.0 Lower 1.2 m24 runs/m2 1p2gout m25 runs/m2 1p2gout m26 runs/m2 1p2gout 7.0 Lower 1.4 m24 runstm2 lp4g.out n25 runs/m2 lp4gout m26 rans/m2 1p4g.out 7.0 Lower 1.6 m24 runs/m2 1p6g.out m25 runs/m2 1p6geout m26 runsln2 1p6e.out 7.8 Lower 0.1 m27 runs/n2 p1g.out mn28 runs/m2 i1gout m29 runs/m2 p1gout 7.8 Lower 0.2 m27 runs/mi p2g.out m2S runs/m2 p2g.out m29 runsfni2 _2g.out 7.8 Lower 0.3 m27 runs/rn2 p3g.out m28 rans/m2 p3g.out m29 runs/m2 p3g.out 7.8 Lower 0.4 m27 runs/m2 p4gout m28 runs/m2 p4g.out m29 runs/m2 p4gout 7.8 Lower 0.5 m27 runs/rn2 p5g.out m28 runshn2 p5g.out m29 runs/m2 2Sg.out 7.8 Lower 0.6 m27 runs/mn2 p6g.out m28 mns/m2 p6g.out m29 runs/mi p6g.out 7.8 Lower 0.7 m27 runs/m2 p7g.out m28 runs/m2 D7g.out m29 runs/m2 p7g out 7.8 Lower 0.8 m27 runs/m2 p8gout m28 runs/m2 p8g.out m29 runs/rn2 pgg.out 7.S Lower 0.9 m27 nxns/m2 p9gout m28 runs/m2 p9gout m29 runs/,m2 p9g.out; 7.8 Lower 1.0 m27'runs/rm2 1pOg~out m28 runs/m2 Ip0gout m29 runs/ma2 IpOgout 7.8 Lower 1.2 m27

=uns/mi lp2gout m28 runs/m2 lp2g.out m29 runslm2 Ip2g&out 7.8 Lower 1.4 m27 runs/mi Ip4gout r

n28 runs/m2 1p4g.out m29 runs/mi 1 out 7.8 Lower 1.6 m27 runs/m2 Ip6gout m2S runs/m2 Ip6gout m29 runs/m2 1I6gout

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 12 of 349 Date: 08/27/03 Table 6-3c. File names for soil spectra for the upper profile M

Soil Rock Set I Set 2 Set 3 Profile PGA (g) 6.0 Upper 0.1 m3l runs/m3 21S.out rn32 runs/m3 p1g.out m33 runskn3 I out 6.0 Upper 0.2 m31 runs/m3 p2g.out m32 runslm3 p2g.out m33 runsm3 p2g.out 6.0 Upper 0.3 m31 runs/m3 p3g.out r32 suns/m3 p3g.out m33 ntns/m3 3gout 6.0 Uppr 0.4 m31 runsim3 p4g.out m32 tuns/m3 p4g out m33 runs/m3 p4g.out 6.0 Upper 0.5 m31 runshn3 p5g.out m32 runsim3 p5g.out m33 runs/m3 p~g.out 6.0 Upper 0.6 m31 runs/m3 p6g.out m32 runs/m3 p6g.tout m33 runs/m3 p~g.out 6.0 Upper 0.7 m31 runs/m3 p7g.out m32 runs/m3 p7g.out m33 runs/m3 p7g.out 6.0 Uppe 0.7 m31 runs/m3 p8g.out m32 runstm3 p8g.out m33 runstrn3 p8itout 6.0 Upper 0.9 m31 runsl/n3 p9.Rout m32 runs/m3 p9g.out m33 runs/m3 p9g.out 6.0 Upper 1.0 mn31 runs/m3 1p0a.oult m32 runs/m3 IpOg.out m33 runs/m3 IpOg.out 6.0 Upper 1.2 m31 runs/m3 Ip2e.out m32 runs/m3 Ip2g.out m33 runs/m3 Ip2g.out 6.0 Upper 1.4 m31 runs/m3 Ip4g.out m32 runs/m3 Ip4g.out m33 runs/m3 lp4g.out 6.0 Upper 1.6 m31 runstm3 Ip6g.out m32 runstm3 Ip6g.out m33 runs/m3 1p6g.out 7.0 Upper 0.1 m34 runs/m3 pig.out rn3S runslm3 pIg.out m36 runsfm3 pig.out 7.0 Uppe 0.2 m34 suns/m3 p2s.out m3S runstm3 p2g.out m36 runs/rn3 p2g.out 7.0 Upper 0.3 rn34 runs/m3 p3g.out m35 runs/m3 p3g.out m36 runs/m3 p3g.out 7.0 Upper 0.4 m34 nms/m3 p4g.out m35 tuns/rn3 p4g.out m36 runs/m3 p4g.out 7.0 Upper 0.5 m34 runs/m3 p5gout m3S runstm3 p5g.out m36 runs/m3 p5g.out 7.0 Upper 0.6 rn34 runs/m3 p6g.out m35 runs/rn3 p6g.out m36 runstn3 p6g.out 7.0 17Uper 0.7 mn34 runs/m3 p7g.out m35 runs/n3 plg.out m36 runstm3 p7g.out 7.0 Upper 0.8 m34 runs/rm3 p8g.out rn35 runs/m3 p8g.out m36 runs/n3 p8g1out 7.0 Uper 0.9 m34 runs/m3 p9zout m35 runs/n3 p9g.out m36 runs/m3 p9g.out 7.0 Upper 1.0 I

m34 runstim3 IpOgout m35 runs/nn3 IpOg-out m36 runslm3 IpOg.out 7.0 Upper 1.2 m34 runs/n3 lp2g.out m35 runs/n Ip2g.out m36 runs/m3 lp2g.out 7.0 Upper 1.4 m34 insfmm3 'Ip4g.out m35 nns/m3 lp4g.out m36 runs/m3 Ip4g.out 7.0 Upper 1.6 m34 inusim3 Ip6g.out rn35 runs/m3 Ip6g.out m36 runs/m3 lp6g.out 7.8 22er 0.1 m37 muns/n3 pig.out m38 runs/m3 plg.out m39 runs/m3 plg.out 7.8 Upper 0.2 m37 runs/m3 p2gout m38 rnns/m3 p2g.out m39 runs/W3 p2g.out 7.8 Upper 0.3 m37 runsfm3 p3g.out n*38 runs/m3 p3g.out m39 runs/m3 p3g.out 7.8 Upper 0.4 m37 runsfm3 p4g.out m38 runslm3 p4g.out rn39 nrus/sm3 p4g.out 7.8 Upper 0.5 m37 runs/m3 p5gout m38 runs/m3 p5g.out m39 runstm3 p5gout 7.8 Upper 0.6 m37 runstm3 p6g.out -

m3S runstrn3 p6g.out m39 runs/m3 p6g out 7.8 Upper 0.7 m37 runsfni3 plg.out m38 runshn3 p-7g.out r39 runtn3 p~g.out 7.8 Upper 0.8 m37 runs/rn3 p8g.out m38 runs/t3 p8g.out m39 runs/m3 p~g.out 8.:

Upper 0.9 m37 runs/m3 p9g.eout.

m38 runs/m3,p9gout m39 runs/t3 p9g.out 7.8 Upper 1.0 m37 runs/m3 IpOg.out m38 runs/m3ipOgfout m39 runs/m3 ipOg.out 7.8 per 1.2 m37 runis/m3 Ip2g.out nm38 russs/m3 lp2g.out m39 runs/m3 Ip2g.out 7.8 Upper 1.4 m37 rxunsm3 Ip4g.out m38 runsfsm3 lp4g.out m39 runs/m3 Ip4g.out 7.S Upper 1.6 m37 runs/m3 Ip6g.out m38 runs/mn3 Ip6g.out m39 rurs/m3 Ip6gout

CabcNumber: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: I13 of 3 49 Date: 08/27/03 )

~~~Table 6-4a. Soi Spectra for M=6.0, Set 1, Median Soil Profile 0.04) 0.187 0.329 0.423 g 0.417 0.597 0.6726 0.745 0.8172 0.8872 0.92 1.089 1.2012 1.270 0.05 0.2047 0.3467 0.4358 0.3493 0.6294 0.7025 0.7732 0.8432 0.9114 0.9740 1.1068 1.2200 1.2836 0.06 0.2327 0.3827 0.4842 0.5,29 0.6645 0.7380 0.8083 0.8766 10.9414 1.0014 11.1303 1.2400 1.30-20 0.07 0.2483 0.3908 0.5039 0.5773 0.6228 0.6875 0.7677 0.8448 10.9151 0.9757 11.1128 1.2365 1.30816 0.08 0.2965 0.4759 0.6079 0.7032 0.7856 0.8556 0.9176 0.9777 1.0369 1.0902 11.2113 1.3104 1~.3590 0.9 0.3065 0.5237 0.6760 0.7864 0.8721 0.9431 1.0053 1.0646 1.1196 1.1630 11.2709 1.3670 I.4127 0.10 0.3770 0.5907 0.7608 0.9114 0.9923 1.0280 1.0344 1.0237 0.9983 1.0592 1.1988 1.322

..3923 0.11 0.4292 0.6353 0.7729 0.9313 1.0291 1.1445 1.2214 1.2677 1.2844 1.2513 1.23 48 1.393 11.4308 0.12 0.4499 0.6865 10.9160 1.08-71 1.1965 1.2824 1.3381 1.3665 1.3609 1.2936 1.3267 1.4493 1.5035 0.13 0.5420 0.8745 11.0779 1.2545 1.3616 1.4197 1.44012 1.4438 11.4840 1.5390 1.6412 1.7087 1.7093 0.14 0.4987 0.8085 1.0171 1.1884 1.3120 1.4152 1.5021 1.5786 1.6403 1.6744 1.7447 1.7964 1.-7876 0.15 0.4195 0.8240 1.0571 1.1715 1.3200 1.4695 1.5598 1.5955 1.5906 1,5648 11.5171 1.5879 1.6132 0.16 0.4734 0.8276 1.0907 1.2660 1.4674 1.6429 1.7500 1.8013 1.8090 1.7839 11.7646 1.6913 1.6189 0.17 0.5149 0.9367 1.1985 1.4211 1.6594 1.8506 1.9809 2.0593 2.0902 2.0405 1.9518 1.8646 1.7766 0.18 0.4816 0.8280 1.1845 1.5059 1.7785 2.0081 2.1720 2.2783 2.3321 2.2925 2.0916 1.8598 1.8255 0.19 0.5479 0.9557 1.2826 1.5736 1.8004 1.9816 2.1249 2.2405 2.3216 2.3249 2.2534 2.1684 2.1203 0.20 0.5663 1.0108 1.3693 1.6987 1.9609 2.1-761

'2.3514 2.4872 2.5791 2.5870 2.5009 2.4027 2.3210 0.2 1 0.5342 0.9830 1.3466 1.6809 1.9522 2.1788 2.3559 2.4928 2.5867 2.5981 2.5234 2.4116 2.3215 0.22 0.5284 0.9749 1.3368 1.6792 1.9594 2.1931 2.3800 2.5274 2.6315 12.6554 2.5838 2.4594 2.3 526 0.23 0.5072 0.9368 1.3152 1.6712 1.9675 2.2052 2.3976 2.5524 2.6616 12.6903 21.6059 12.4727 2.3539 0.24 0.5198 0.9846 1.396-7 1.7695 2.0740 2.3214 2.5190 2.6845 2.8035 2.8422 12.7609 12.6288 2.4958 0.25 0.5180 0.9899 1.4038 1.7767

-2.0880 12.344-7 2.5607 2.7400 2.8726 2.9238 2.8630 12.7:213 12.5677 0.26 0.5154 '1.01 15 11.4376 1.8158 2.1230 12.3595 2.5334 2.7041 2.8437 2.9079 2.8689 2.7344 12.5677 0.27 0.5038 0.9943 1.4312 1.8250 2.1530 2.4165 2.6102 2.7657 2.8665 2.8750 2.7476 2.6271 12.4528 0.28 0.4607 0.9160 1.3391 1.7272 2.0555 2.3265 2.5402 2.7104 2.8302 2.8720 2.7230 2.5 180 2.3324 0.29 0.4295 0.8883 1.2657 1.6479 1.9809 2.2627 2.4949 2.6843 2.8336 2.9578 3.0106 2.8349 2.6451 0.30 0.4075 0.8713 1.3234 1.6988 1.9940 2.2550 2.5069 2.7238 2.9606 3.1424 3.1958 2.9931 2.7811 0.31 0.3823 0.8064 1.2285 1.6283 1.9846 2.2983 2.5656 2.8041 2.9961 3.1142 3.0893 2.8465 2.5246 0.32 0.3627 0.7748 1.1945 1.5955 1.9596 2.2849 2.5655 2.8182 3.0221 3.1545 3.1333 2.8878 2.8230 0.33 0.3260 0.7107 11.1137 1.5048 1.8640 12.1885 2.4746 12.7253 2.9381 3.0728 13.0648 13.1707 13.1582 0.34 0.3186 0.5967 0.9556 1.3097 1.6388 11.9350 2.1977 2.4359 2.6342 2.8130 13.1877 13.3933 13.3897 0.35 0.3258 0.5926 0.8547 1.1276 1.4067 1.6864 1.9720 2.2613 2.5428 2.7969 3.2215~

3.4454 3.4667 0.36 0.3220 0.5846 0.8404 1.1055 1.3768 1.6489 1.9274 2.2107 2.4881 2.7390 3.1767 3.4274 3.4791 0.37 0.3-212 0.5924 0.8400 1.0739 1.3233 1.5861 1.8573 2.1352 2.4098 2.6627 3.1145 3.3942 3.4787 0.38 0.3252 0.5995 0.8498 1.0844 1.3 101 1.5295 1.7631 2.0342 2.3046 2.5578 3.0243 3.3299 3.4497 0.39 0.3251 0.5998 0.8476 1.0794 1.3012 1.5162 1.7329 11.9553 2.1732 2.4153 2.8935 3.2264 3.3829 0.40 0.3216 0.5926 10.8351 1.0603 1.2756 1.4845 1.6949 11.9100 2.1206 2.3087 2.7277 3.0858 3.2819

-41 0.3159 0.sg580A5.-

,,..1.61 1.0328

.1.2386 1.4377 1.6382 1.8434 2.0465.. 2.2264.2.5932 2.~0 3.1692 0.42 0.3098 0.5677 0.7940 1.0006 1.1955 1.3832 1.5735 1.7702 1.9630 2.1331 2.4854 2i-Ti2 '-3.0651 0.43 0.3184 0.5541 0.7702 0.9822 1.1846 1.3703 1.5459 1.7183 1.8813 2.0341 2.3-783 2.6649 2.9885 0.44 0.3439 0.5869 0.7836 0.9580 1.1164 1.2964 1.4750 1.6468 1.8040 1.9272 2.2558 2.5416 2.9114 0.45 0.3386 0.6116 0.8355 1.0095 1.1406 1.3336 1.5169 1.6938 1.8561 1.9834 2.2147 2.4665 12.8471 0.46 0.3406 0.6297 0.8670 1.0568 1.2024 1.3593 1.5461 1.7266 1.8925 2.0242 2.2663 2.4398 12.7368 0.47 0.3312 0.6216 0.8615 1.0580 1.2129 1.3691 1.5579 11.7409 1.9098 2.0435

'2.2928 2.4732 12.6144 0.48 0.3156 0.5983 0.8339 1.0271 1.1784 1.3655 1.5543 1.7372 1.9062 2.0413 2.2948 2.4814 2.6268 0.49 0.3071 0.5893 0.8'298 1.0317 1.1896 1.3531 1.5409 1.7233 1.8920 2.0264 2.2804 2.4681 2.6163 0.50 0.2939 0.5708 0.8120 1.0165 1.1793 1.3358 1.5219 1.7021 1.8692 2.0023 2.2556 2.4447 2.5950 0.51 0.2775 0.5446 0.7805 0.9832 1.1461 1.3170 1.5007 1.6788 1.8435 1.9746 2.2247 2.4125 2.5635 0.52 1 0.2581 0.5109 0.7368 0.9627 1.1703 1.3441 1.4847 1.6503 1.8119 1.9406 2.1871 12.3743 2.5269 0.53.

0.2360 0.4708

.0.7413 0.9973 1.2172 1.4018 1.5507 1.6796 1.7779 1.9005 2.1421 2.3265 2.4794 0.54 0.2239 0.4623 0.7284 0.9862 1.2178 1.4200 1.5894 1-.7311 1.8365 1.8763 2.0859 2.2664 2.4193 0.55 0.2111 0.4316 0.6930 0.9484 1.1761 1.3744 1.5405 1.6806 1.7854 1.8613 2.0385 2.1935 2.3462 0.56 0.2016 0.405I 0.6339 0.8711 1.0826 1.2668 1.4217 1.5722 1.7192 1.8295 2.0141 2.1139 2.2581 0.57 0.1914 0.3856 0.5847 0.7939 0.9935 1.1797 1.3521 1.5145 1.6610 1.7740 1.9645 2.0688 2.1568 0.58 0.1805 0.3680 0.5677 0.7696 0.9626 1.1450 1.3158 1.4779 1.6258 1.7438 1.9394 2.0519 2.1461 0.60 0.1702 0.3546 0.5479 0.7444 0.9342 11.1164 1.2892 1.4543 1.6064 1.7277 1.9223 2.1079 2.26 0.62 0.1543 0.3232 0.5015 0.6829 0.8589 1.0286 1.1900 1.3437 1.4845 1.6068 1.8616 2.0503 2.1685 0.64 0.1412 0.2908 0.4460 0.6094 0.7711 T0.9266 1.0757 ji195 1.3s558 1.4789 1.7195 1.9170 12.0504 0.66 0.1380 I0.2833 0.4323 0.5885 0.7438 0.8941 1.0390 1.j 9 1.3150 1.4418 1.7001 1.9242 12.0735

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 14 of 3 49 Date: 08/27/03 0.68 0.1407 I0.2890 04413 0.6007 0.68 099 1.0718 1.2231 1.3706 1.5129 1.04 205 12.2116 0.70 0.1366 0.2824 0.4338 0.5925 0.7535 0.9142 1.0740 1.2329 1.3893 1.5425 1.8498 2.1I022 12.2476 0.72 0.1394 0.2660 0.3807 0.5238 0.6704 -0.8191 0.9693 1.1203 1.2700 1.4169 1.7056 1.9301 12.0459 0.74 0.1441 0.2780 0.3980 0.5112 0.6172 -0.7165 0.8296 0.9479 1.069-7 1.2001 1.92 178 2.0528 0.76 0.1465 0.2851 0.4114 0.5316 0.644-7

-0.7506 0.852.5 0.9550 1.0597 1.1726 1.4378 I1.74R0 2.0568 0.78 0.1465 0.2872 0.4171 0.5414 0.6589 0.7691 0.8748 0.9801 1.0864 1.1982 1.4342 3L16696 1.9291 0.80 0.1445 0.2849 0.4159 0.5418 0.6613 10.7737 0.8810 '0.9876 11.0942 1.2047 1.4340 I1.6596 1.8661 0.82 0.1412 0.2797 0.4098 0.5356 0.6551 0.7678 0.8756 0.9822 11.0879 1.1965 1.4187 1.6344 1.8318 0.84 0.1376 0.2733 0.4017 0.5262 0.6448 0.7568 0.8640 0.9699 11.0-745 1.1808 1.3959 1.,6028 1.7915 0.86 10.1341 0.2671 0.3937 0.5164 0.6338 0.7449 0.851I1 0.9559 11.0591 1.1632 11.3723 11.5718 1.7531 0.88 0.1312 0.2617 0.3865 0.5077 0.6240 0.7340 0.8393 0.9431 11.0449 1.1473 11.3516 1.5456 11.7213 0.90 0.1287 0.2570 0.3803 0.5003 0.6153.0.7245 0.8290 0.931.9 11.0328 11.1338 1.3349 1.5244 1.6962 0.92 0.1265 0.27529 0.3746 0.4934 0.6073 0.7157 0.8195 0.9211 1.0218 11.1218 1.3205 1.5067 1.6758 0.94 0.1243 0.2487 0.3690 0.4865 0.5993 0.7067 0.8099 0.9115 1.0109 1.1100 1.3069 1.4908 1.6578-0.96 0.1220 0.2444 0.3630 0.4791 0.5908 0.6972 0.7996 0.9005 0.9992 1.0975 1.2927 1.4749 1.6406 0.98 0.1196 0.2397 0.3566 0.4711 0.5816 0.6870 0.7884 0.8884 0.9863 1.0837 1.2773 1.4579 1.6224 1.00 0.1170 0.2348 0.3498 0.4627 0.5717 0.6758 0.7761 0.8752 0.9721 1.0685 11.2605 1.4395 1.6029 1.05 0.1151 0.2221 0.3317 0.4397 0.5443 0.6445 0.7414 0.8372 0.9313 1.0252 1.2132 1.3892 1.5498 1.10 0.1177 0.2267 0.3243 10.41-70 0.5134 0.6090 0.7019 0.7941 0.8850 0.9761 1.1607 1.3344 1.4941 1.15 0.1175 0.2253 0.3192 0.4062

.0.4836 0.5728 0.6617 0.7501 0.8376 0.9263 1.1076 1.2800 1.4391 1.20 0.1067 0.2086 0.3020 0.3923 0.4768 0.5538 0.6366 0.7197 0.8022 0.8865 1.0611 1.2297 1.3863 1.25 I0.0978 0.1939 0.2861 0.3747 0.4576 0.5347 0.6154 0.6951 0.7737 0.8536 1.0193 1.1817 1.3340 1.30 10.0885 0.1783 0.2656 0.3519 0.4365 0.5175 03.59-46 0.6697 10.7454 0.8219 0.9795 1.1357 1.2837 11.35 10.0826 0.1684 0.2549 0.3424 0.4299 0.5158 0.5995 0.6817 0.7614 0.8385 0.9808 11.0997 1.2391 1.40 0.0813 0.1674 0.2559 0.3450 0.4338 0.5215 0.6073 0.6919 0.7746 0.8552 1.0063 1.1347 1.2366 1.45-0.0810 0.1662 0.2544 0.3435 0.4325 0.5201 0.6059 0.6907 0.7738 0.8553 1.0104 1.1450 1.2542 1.50 0.0790 0.1619 0.2478 0.3351 0.4225 0.5087 0.5932' 0.6766 0.7585 0.8394 0.9954 1.1337 1.2485 1.55 0.0752 0.1542 0.2363 0.3201 0.4045 0.4881 0.5702 0.6514 0.73 12 0.8105 0.9655 1.1061 1.2266 1.60 0.0699 0.1438 0.2210 0.3002 0.38016 0.4607 0.5400 0.6186 0.6962 0.7739 0.9275 1.0714 1I.1984 1.65 0.0648 0.1321 0.2039 0.2779 0.3540 0.4307 0.5077 0.5848 0.6617 0.7394 0.8923 1.03177 11.1682 1.70 0.0618 0.1251 0.1892 10.2581 0.3305 0.4048 0.4800 0.5553 0.63116 0.7068 0.8564 1.0001 1.1315 1.75 0.0585 0.1185 0.1793 0.2414 0.3094 0.3794 0.4507 0.52'27 10.5951 0.6689 0.8148 0.9560 1.0867 1.80 0.0549 0.1114 0.1688 0.2270 0.2860 10.3515 0.4188 0.4870 0.5560 0.6267 0.7673 0.9125 1.0763 1.85 0.511 0.1041 0.1580 0.2126 0.2682 10.3241 0.3851 0.4487 0.5133 0.5852 0.7389 0.9003 11.0554 1.90 0.0473 0.0966 0.1470 0.1979 0.2498 10.3022 0.3549 0.4079 0.4677 0.5296 0.6628 0.8215 10.9813 1.95 0.0434 0.0889 0.1356 0.1830 0.2312 0.2801 0.3295 0.3793 0.4297 0.4866 0.6096 10.7355 10.8700 2.00 0.0397 0.0813 0.1243 0.1681 0.2129 0.2585 0.3051 0.3526 0.4009 0.4513 0.5674 0.6871 0.8120 2.05 0.0378 0.0762

0. 1145 0.1538 0.1955 0.2386 0.2831 0.3284 10.3745 0.4219 0.5278 0.6409 0.7535 2.0

.0358 0.0722 0.1086 0.1449 0.1810 -0.2206 0.2627 0.3055 10.3490 0.3939 0.4883 0.5958 0.7047 2.15 0.0338 0.0683 0.1028 0.1372 0.1714 0.2053 0.2434 0.2835 0.3244 0.3666 0.4524 0.5539 0.6647 2.20 0.0318 0.0645 0.0971 0.1297 0.1621 0.1941 0.2258 0.2624 0.3007 0.3404

-0.4216 0.5250 10.6367 2.25 0.0300 0.0608 0.916 0.1224 0.1530 0.1833 0.2133 0.2432 0.2782 0.3156

-0.4001 0.5014 10.6074 2.30 0.0282 0.0573 0.0864 0.1155 0.1469 0.1796 0.2137-0.2490 0.2858 0.3249 0.4096 0.5053 10.6131 27.35 0.02-75

-0.0564 0.0865 I'-.1178 0.1501 ~1T-A38 ~:0.2187 0.2550 0.2927 0.3329 0.41989 0:5175 i0,6270 2.40 0.0261 0.0536 0.0825 0.1125 0.1436 0.1759 0.2097 0.2446 0.2811 0.3200 0.4041 0.4988 10.6047 2.50 0.0224 0.0456 0.0688 0.0921 0.1178 0.1446 0.1726 0.2015 0.2314 0.2630 0.3293 0.4012 10.4888 2.60 0.0218 0.0439 0.0668 0.0906 0.1151 0.1404 0.1663 0.1929 0.2204 0.2491 0.3104 0.3767 10.4467 2.70 0.0209 0.0424 0.0641 0.0861 0.1088 0.1323 0.1569 0.1823 0.2085 0.2363 0.2951 0.3609 0.4307 2.80 0.0188 0.0384 0.0585 0.0788 0.0996 0.1210 0.1431 0.1659 10.1896 0.2146

-0.2677 0.3267 0.3909 2.90 0.0163 0.0327 0.0497 0.0672 0.0853 0.1038 0.1230 0.1428 0.1634 0.1853 0.23 19 0.2833 0.3394 3.00 0.0152 0.0305 0.461 10.0617 0.0774 0.0930 0.1097 0.1273 0.1456 0.1646 0.2056 0.2503 0.2972 3.10 0.0138 0.0278 0.0421 0.0565 0.0710 0.0856 0.1001 0.1147 0.1309 0.1483 0.1852' 0.2256 0.2684 3.20 0.0128 0.0258 0.0387 0.0516 0.0644 0.0775 0.0910

-0.1050 0.1196 0.1353

-0.1693 0.2066 0.2461 3.30 0.0119 0.0240 0.0361 0.0482 0.0602 0.0724 0.0849 0.0977 0.1111 0.1252 0.1558 0.1898 0.2265

-3.40 Q.0108... 0.0219 0.0334 0.0453 0.0574 0.0697 0.0824 0.0952 0.1083 0.1218 0.1498 0.1792 0.2101 3.50 0.0098 -'0.0198 0.0299 0.0407 0.0519 0.0633 0.0751 0.0871 0.0994 0.1121 0.1386 0.1668 0.1966 3.60 0.0096 0.0193 0.0290 0.0387 0.0485 0.0583 0.0681 0.0781 0.0881 0.0990 0.1224 0.1483 0.1763 3.70.

0.0095 0.0191 0.0286 0.0382) 0.0477 0.0573 0.0668 0.0763 0.0859 0.0955 0.1182 0.1435 0.1712 3.80 0.0091 0.0182 0.0275 0.0367 0.0460 0.0554 0.0647 0.0742 0.0836 0.0932 0.1125 0.1364 0.1631 3.90 0.0W086 0.0173 0.0262 0.0352 0.0442 0.0533 0.0625 0.0717 0.0810 0.0901 0.1086 0.1291 0.1538 4.00 0.0080 0.0163 0,0247 0.0332 0.0418 0.0505 0.0593 0.0681 0.0770 0.0858 0.1036 0.1224 0.1442 4.10 0.0074 0.0150 0.0228 0.0307 0.0387 0.0469 0.0552 0.0635 0.0719 0.0803 0.0972 0.1148 0.1345 4.20 0.0069 0.0139 0.0210 0.0282 0.0351 0.0434 0.0514 0.0596 0.0679 0.0763 0.0937 0.1120 011 4.30 0.0067 0.0135 0.0204 0.0275 0.0348 0.0423 0.0501 0.0581 0.0663 0.0747 10.0920 0.1102 0129 4.40 0.0064 0.0130 0.0196 0.0264 0.0334 0.0407 0.0483 0.0561 0.0641 0.0723 10.0893 I0.1071 015

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 15 of 349 Date: 08/27/03 4.50 0.0061 0.0123 0.0186 0.0251 0.0318 0.0387 0.0460 0.0534 0.0611 0.0690 0.0855 0.1029

'0.1211 4.60 0.0057 0.0116 0.0175 0.0236 0.0298 0.0363 0.0431 0.0501 0.0574 0.0650 0.0808 0.0975 0.1151 4.70 0.0054 0.0108 0.0163 0.0219 0.0276 0.0335 _ 0.0398 0.0464 0.0531 0.0602 0.0752 0.0910 0.1078 4.80 0.0052 0.0104 0.0156 0.0208 0.0259 0.0309 0.0422 0.04X4 0.0550 0.06X9 0.0837 0.0996 4.90 0.0051 0.0102 0.0154 0.0206 0.0257 0.0308 0.0357 0.0407 0.0455 0.0506 0.0625 0.0758 0.0906 5.00 0.0050 0.0100 0.0151 0.0202 0.0253 0.0303 0.0352 0.0401 0.0450 0.0499 0.0611 0.0733 0.0857 5.10 0.0048 0.0097 0.0146 0.0196 0.0246 0.0295 0.0344 0.0395 0.0446 0.0499 0.0603 0.0713 0.0834 5.20 0.0046 0.0093 0.0141 0.0190 0.0239 0.0289 0.0340 0.0391 0.0442 0.0495 0.0599 0.0703,0.08O 5.40 0.0043 O.00S7 0.0133 0.0179 0.0226 0.0274 0.0322 0.0371 0.0421 0.0471 0.0572 0.0674 0.0773 5.60 0.0039 0.0079 0.0121 0.0163 0.0206 0.0249 0.0294 0.0339 0.0384 0.0431 0.0525 0.0621 0.0717 5.80 0.0034 0.0069 0.0106 0.0143 0.0181 0.0220 0.0259 0.0299 0.0340 0.0381 0.0466 0.0554 0.0643 6.00 0.0029 0.0059 0.0090 0.0122 0.0154 0.0187 0.0221 0.0256 0.0291 0.0327 0.0402 0.0480 0.0564 6.20 0.0027 0.0054 0.0081 0.0108 0.0134 0.0161 0.0190 0.0220 0.0251 0.0283 0.0350 0.0423 0.0501 6.40 0.0026 0.0051 0.0076 0.0102 0.0128 0.0154 0.0180 0.0205 0.0230 0.0255 0.0306 0.0372 0.0441 6.60 0.0025 0.0049 0.0074 0.0100 0.0125 0.0150 0.0176 0.0201 0.0225 0.0249 0.0294 0.0334 0.0386 6.80 0.0024 0.0048 0.0072 0.0097 0.0121 0.0146 0.0170 0.0195 0.0219 0.0242 0.0286 0.0325 0.0358 7.00 0.0023 0.0047 0.0070 0.0094 0.0117 0.0141 0.0165 0.0188 0.0211 0.0233 0.0276 0.0315 0.0348 7.20 0.0022 0.0045 0.0067 0.0090 0.0113 0.0135 0.0158 0.0181 0.0203 0.0224 0.0266 0.0303 0.0336 7.40 0.0022 0.0043 0.0064 0.0086 0.0108 0.0129 0.0151 0.0173 0.0194 0.0215 0.0254 0.0291 0.0323 7.60 0.0021 0.0041 0.0061 0.0082 0.0103 0.0123 0.0144 0.0165 0.0185 0.0205 0.0243 0.0278 0.0309 7.80 0.0020 0.0039 0.0058 0.007 00098 O

0.0117 0.0137 0.0157 0.0176 0.0195' 0.0231 0.0265 0.0295 8.00 0.0019 0.0037 0.0055 0.0074 0.0093 0.0111 0.0130 0.0149 0.0167 0.0185 0.0220 0.0252 0.0281 8.50 0.0016 0.0032 0.0048 0.0064 0.0081 0.0097 0.0114 0.0130 0.0146 0.0162 0.0193 0.0221 0.0247 9.00 0.0014 0.002S 0.0042 0.0056 0.0070 0.0085 0.0099 0.0113 0.0127 0.0141 0.0169 0.0194 0.0216 9.50 0.0012 0.0024 0.0036 0.0048 0.0061 0.0073 0.0086 0.0099 0.0111 0.0123 0.0148 0.0170 0.01S9 10.00 0.0010 0.-021 0.0031 0.0042 0.0053 0.0064 0.0075 0.0086 0.0097 0.0108 0.0129 0.0149 0.0 166

Calc Number: GE0. HB [P.03.02 Rev Number: 0 Sheet Number: 16 of-349 Date: 08/27/03

_____~Table 6-4b. Soil Spectra for M~=6.0, Set 2, Median Soil Profile Per (seq)

O-lg 0.2g 0.3g 0.4g 0.5g 0.6g 0.7R 0.8e 0.9,R L.0 1.7g 1.4c

.i 0.01 0.1547 0.3172 0.4416 0.5266 0.5352 0.6420 0.7461 0.3332 0.9008 0.9512 1.0311 1.0941 1.1413 0.03 0.1592 0.3244 0.4500 0.5343 0.5936 0.6508 0.7559 0.8438 0.9117 0.9626 1.0425 1.1057 1.1531 0.04 0.1598 0.3277 0.4558 0.542-4 0.019 0.6531 0.7604 0.8501 0.9196 0.9712 1.0523 1.1160 1.1640 0.05 10.1671 0.3400 0.4702 0.5577 0.6161 0.6615 0.7562 0.8365 0.9049 0.9602 1.0483 I~1.1114 1.1690 0.06 10.1963 10.3459 0.4864 10.57-72 10.6350 10.6-709 10.7714 0.8538 0.9224 0.9753 11.0626 1.1309 1.1830 0.07 10.2194 10.3638 0.5068 10.5922 10.6487 10.6972 10.7775 0.8552 0.9195 0.97-20 11.0616 1.1339 11.1.900 0.08 10.2659 10.4688 10.5983 10.6898 10.8026 10.9026 10.9875 1.0543 1.1061 1.1423 1.2020 11.2481 1.-28121 0.09 0.2923 10.5393 10.6809 0.8032 0.9257 1.0284 11.1133 1.1808 1.2333 11.2677 11.3259 11.3672 11.3945 0.10 0.3020 0.5353 0.7124 0.8393 0.9477 1.0300 1.1059 1.1707 1.2261 1.2640 11.3240 11.3708 11.4132 0.11 0.4033 0.6842 0.8684 1.0073 1.1146 1.1763 1.2036 1.2007 1.1910 1.1786 11.1919 1.2698 1.3237 0.12 0.4341 0.7491 0.9665 1.1379 1.2744 1.3524 1.3910 1.3967 1.3945 1.3863 11.3866a 1.40127 1.4431 0.13 0.4429 0.7916 1.0414 1.2286 1.3761 1.4648 1.5184 1.5385 11.5461 1.5416 1.6007 1.6769 1.7359 0.14 0.4724 0.8587 1.1242 1.3238 11.4818 1.5932 1.6955 1.7597 11.7880 1.8165 1.8719 1.9407 2.0073 10.15 10.4243 0:7647 1.0431 1.3625 11.6047 1.7569 11.8751 1.9629 12.0479 -2.1188

- 2.19-23 2.1873 2.2050 0.16 0.4656 10.8208 1.1086 1.4319 1.7102 1.9,142 2.0639 12.1744 2.2782 I 2.3683 J2.4902 2.5446 2.5033 0.17 0.5332 1.0431 1.3664 1.5688 1.7109 1.91205 2.0972 2.2266 2.3431 12.4455 2.6053 12.7035 12.7053 0.18 0.4460

-0.8620 1.1276 1.3949 1.7066 1.9679 2.1688 2.3142 2.4353 12.5481 12.7444 12.8872 12.9307 0.19 0.4984 0.9063 1.1588 1.3324 1.5954 11.8707 2.0830 2.2276 2.3514 12.4667 12.6839 12.8708 12.9633 0.20 0.5134 0.9850 1.336-2 1.60q8 1.8401 2.0598 2.2837 2.4671 2.60.57 2.7055 2.8532

-2.9556 3.0171 0.21 0.4684 0.9368 1.2994 11.5810 1.8181 2.0157 2.1972 2.3425 2.4608 2.5551 2.7204 2.8305 2.8857 0.22 0.4806 0.9562 1.3296 11.6272 1.8671 2.0613 12.2308 2.36-73

-2.4857 2.5937 2.7828 2.9064 2.9670 0.23 0.4778 0.9505 1.3343 1.6445 1.9004 2.1028 2.2675 2.3976 12.5 162 2.6226 2.8271 2.9536 3.0080 0.24 0.4819 0.9620 1.3730 1.7152 2.0005 2.2129 2.3684 2.4813 2.5864 2.6943 2.8999 13.0321 13.0938 0.25 0.4893 0.9923 1.4500 1.8329 2.1396 2.3486 2.4696 2.5472 2.6473 2.7330 2.9614 3.1209 13.2096 0.26 0.5065 0.9576 1.3540 1.7212 2.0689 2.3938 2.6788 2.8793 3.0207 3.1110 3.2286 3.2603 13.2514 0.27 0.4900 0.9398 1.3755 1.7766 2.1601 2.5468 2.8918 3.1469 3.3287 3.4497 3.5999 3.6692 13.6982 0.28 0.4640 0.9563 1.4025 1.7632 2.1437 12.5320 2.8745

.3.1459 3.3427 3.4841 3.68971 3.7799 3.7919 0.29 0.4308 10.9151 1.3531 1.6948 1.9729 12.3-286 12.6830 i3.0265 13.3228 13.5720 13.9415

4. 1322 4.1633 0.30 0.3789 0.7971 1.2188 1.6184 1.9883 12.3814 12.7735 13.1297 13.4477 13.7200 14.1541 4.4203 4.5255 0.31 0.3534 0.7721 1.1905 1.5908 1.9612 2.3526 2.7475 13.1084 13.4329 13.7203 14.1986 4.5259 4.6973 0.32 0.3297 0.7253 1.1289 1.5180 1.8796 2.2646 2.6516 3.0162 13.3447 3.6389 4.1516 14.5289 4.7516 0.33 0.3122 0.6682 1.0505 1.4227 1.7699 2.1448 2.5252 2.8822 13.2140 3.5150 4.0511 14.4665 14.7439 0.34 0.3000 0.6053 0.9630 1.3183 1.6508 2.0108 2.3822 2.7365 3.0652 3.3684 3.9255 1439 469 0.35 10.2918 0.5653 0.8779 1.2140 1.,5312 1.8791 2.2377 2.5862 12.9137 3.2192 3.7896 4.2708 46291 0.36 10.2858 0.5508 0.8033 1.1109 1.4111 1.7430 2.0870 2.4240 2.7448 3.0476 3.6228 4.27 452 0.37 0.2801 0.5365 0.7827 1.0284 1.2848 11.5968 11.9214 12.2414 2.5501 2.8430 3.4198 3.39 439 0.38 0.2857 0.5481 0.7793 0.9926 1.2317 11.4950 1.7619 12.0168 2.3047

-2.5853 13.1439 3.6619 14.0927 0.39 0.2832 0.5422 0.7702 0.98-00 1.1631 1.4105 1.6771 1.9285 2.1544 2.3812 2.8282 3.2452 13.6647 0.40 0.2918 0.5570 0.7864 0.9955 1.1758 1.3563 1.5853 1.8302 2.0661 2.2866 2.7237 3.1366 13.5185

-Ml0A1 0.3045

-0.579.5 0.8174 1.0331

.,1.2181 1.4062 1.5836 1.7680 1.9983 2.2165 2.6605 3.0957 13.5068 0.42 0.2961 10.5676 0.8017 1.0145 1.1978 1.3844 1.5616 1.7171 1.8603' 2.0395 2.4680' 2.8938 13.3055 r

0.43 0.2870 10.5514 0.7787 0.9829 1.1560 1.3335 1.5028 1.6516 1.7875 1.9132 2.2335 2.6364 13.0266 0.44 0.2952 0.5539 0.7774 0.9760 1.1430 1.3142 1.4771 1.6189 1.7510 1.8722 2.1350 2.4101 12.7886 0.45 0.2938 0.5425 0.7555 0.9450 1.1196 11.3042 1.4774 1.6304 1.7686 1.8907 2.1368 2.3833 12.6347 0.46 0.2818 0.5219 0.7301 0.9389 1.1290 11.3174 1.4955 1.6540 1.7968 1.9232 2.1780 2.4348 12.6940 0.47 0.2606 0.4977 0.7185 0.9252 1.1144 1.3035 1.4832 1.6440 1.7890 1.9183 2.1727 2.4390 12.7011 0.48 0.25 11 0.499-0 0-.7162 0.8989 1.0819 1.2689 1.4474 1.6081 1.7539 1.8852 2.1462 2.4057 12.6670 0.49 0.2460 0.4848 10.6853 0.8599 1.0410 1.2244 1.4006 1.5604 1.7059 1.8359 2.0949 2.3526 12.6107 0.50 0.2236 0.4387 0.6358 0.8239 1.0002 1.1800 1.3535 1.5119 1.6567 1.7867 12.0431 2.2956 12.5426 0.51 0.2137 0.4202 0.6107 0.7936 0.9664 1.1433 1.3147 11.4718 1.6158 1.7453 1.9989 2.2479 2.4949 0.52 0.2057 0.4056 0.5913 0.7706 0.9413 1.1165 1.2866 11.4430 1.5863 1.7153 1.9665 2.2123 12.4557 0.53 0.1996

-0.3946..-.0.5770 0.7540

.0.938 11.0980 A.26,72 1.423 1 -..1.5652, 1.6945 1.9439

. 2.1873 12.4279 0.54 0.1946 0.3860 0.5661 0.7415 0.9105 11.0838 1.2523 1.4077 1.5500 1.6782 1.9258 2.1673 12.40591 0.55 0.1902 0.3784 0.5564 0.7303 0.8982 1.0703 1.2378 1.3923 1.5338 1.6614 1.9072 2.1470 12.3840 0.56 0.1859 0.370-8 0.5465 0.7185 0.8848 1.0554 1.2214 1.3747 1.5149 1.6413 1.8857 2.1236 12.3584 0.57 0.1814 0.3627 0.5357 0.7054

.0.8696 1.0380 1.2019 1.3535 1.4925 11.6177 1.8604 2.0966 12.3294 0.58 0.1767 0.3542 0.5241 0.6910 0.8527 1.0184 1.1799 1.3296 1.4672 1.5915 1.8321 2.0667 2.2980 0.60 0.1675 0.3370 0.5004 0.6613 0.8177 0.9779 1.1344 1.2804 1.4154 1.5384 1.7757 2.0077 2.2366 0.6 0.1593 0.3217 0.4793 0.6348 0.7868 0.9425 1.0951 1.2386 1.3721 1.4947 1.7749 2.0005 2.1902 0.4 0.1522 0.3087 0.4614-0.6130 0.7619 10.9143 1.0643 1.2063 1.3394 1.4624 1.6997 1.9309 2.1571 0.6 0.1458 10.2966 0.4447 0.5925 0.35 087 105

.755 1.3081 1.4313

-1.6688 1.8994 2.1483

Calc Number. GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 17 of 349 Date: 08/27/03 0.68 023-91 0.2837 0.4266 0.3699 0.7124 0.8578 1.0015 1.1394 11.2704 11.3927 1.6290 1.9035 2.1671 0.70 0.1315 0.2690 0.4059 -0.5435 0.6814 0.8218 0.9608 1.0948 1.2228 1.3430 1.3739 1.8404 12.1094 0.72 0.1234 0.2533 0.3832 j0.5145 0.6471 0.7817 0.9150 1.0441 1.1681 1.2852 1.5092 1.7340 1.9903 0.74 0.1159 0.2383 0.3615 J0.4862 0.6131 0.7416 0.8687 0.9923 1.1115 1.2246 1.4673 1.7273 1.9743 0.76 0.1181 0.2270 0.3418 0.4601 0.5812 0.7036 0.8245 0.9424 1.0565 1.18646 1.4443 1.6987 1.9429 0.78 0.1181 0.2269 0.3297 0.4357 0.5510 0.6675 0.7827 0.9053 1.030-7 1.1566 1.4048 1.6513 1.8893 0.80 10.1177 0.2321 0.3353 0.4308 0.5315 0.6440 0.7593 0.8765 0.9959 1.1159 1.3530 1.5897 1.8199 0.82 0.1193 0.2364 0.3438 0.4447 0.5408 0.6344 0.7290 0.8403 0.9531 1.0669 1.2923 1.51,92 1.7394 0.84 0.1176 0.2339 0.3421 0.4449 0.5435 0.6403 0.7327 0.8191 0.9041 1.0106 1.2233 1.4373 1.6491 0.86 0.1133 0.2259 0.3319 0.4338 0.5318 0.6289 0.7220 0.8093 0.8943 0.9797 1.1583 1.3509 1.5513 0.88 0.1176 0.2265 0.3236 0.4181 0.5133 0.6100 0.7028 0.7878 0.8668 0.9460 1.1188 1.3044 1.4988 0.90 0.1231 0.2375 0.3392 0.4357 0.5323 0.6315 0.7283 0.8187 0.9036 0.9824 1.1323 1.2787 1.4243 0.92 0.128-7 0.2497 0.3573 0.4577 0.5549 0.6505 0.7448-0.8352 0.9221 1.0038 1.1609 1.3153 1.4689 0.94 10.1313 0.2562 0.3688 0.4739 0.5749 0.6717

'0.7645 0.8524 0.9378 1.0193 1.1766 1.3317 1.4869 0.96 0.1306 0.2565 0.3714 0.4793 0.5828 0.6814 0.7746 0.8620 0.9468 1.0279 1.1838 1.3363 1.4882 0.98

0. 1273 0.2516 0.3664 0.4750 0.5791 0.6784 0.771 8 0.8586 0.9425 1.0231 1.1776 1.3274 1.4746 1.00 0.1224 0.2431 0.3560 0.4634 0.5667 0.6655 0.7580 0.8439 0.92164 1.0059 1.1583 1.3051 1.4475 1.05 0.1089 0.2179 0.3223 0.4231 0.5209 0.6154 0.7038 0.7852 0.8630 0.9377 1.0818 1.2202 1.3520 1.10 0.1106 0.2156 0.3096 0.3970 0.4846 0.5749 0.6596

-0.7374 0.8112 0.8817 1.0180 1.1492 1.2738 1.15 0.1039 0.2061 0.3018 0.3950 0.4858 0.5742 0.6574 0.7325 10.8019 0.3655 0.9837 1.1048 1.2255 1.20 0.1085 0.2173 0.3202 0.4187 0.5146 0.6081 0.05S7 0.7734 0.8448 0.9164 1.0506 1.1772 1.2953 1.25 0.1063 0.214-7 0.3197 0.4'212 0.5198 0.6152 0.7096 0.7989 0.8832 0.9625 1.1097 1.2469 1.3746 1.30 0.1011 0.2040 0.3062 0.4079 0.5094 0.6095 0.7056 0.7954 0.8803 0.9603 1.1095 1.24819 1.3791 1.35 0.0934 0.1893 0.2844 0.3784 0.4723 0.5654 0.6554 0.7395 0.8192 0.8947 1.0367 1.1'710 1.2975 1.40 0.0827 0.1671 10.2507 0.3333 0.4157 0.4981 0.5780 10.6554 0.7357 0.8104 0.9578 1.0941 1.2115 1.45 0.0746 0.1543 0.2375 0.3241 0.4129 0.5039 0.5952 0.6843 0.7697 0.8507 0.9972 1.1290 1.2511 1.50 0.0720 0.1491 0.2307 0.3152 0.4023 0.4942 0.5885 0.6823 0.7737 0.8615 1.0223 1.1656 1.2890 1.55 0.0673 0.1405 0.2200 0.3034 0.3903 0.4808 0.5740 0.6677 0.7600 0.8496 1.0151 1.1633 1.2909 1.60 0.0641 0.1335 0.2087 0.2876 0.3701 0.4561 0.5450 0.6353 0.7249 0.8126 0.9759 1.1236 1.2633 1.65 0.0606 0.1259 0.1968 0.2712 0.3488 0.4296 0.5135 0.5998 0.6865 0.7731 0.9394 1.0962 1.2394 1.70 0.0567 0.1176 0.1837 0.2535 0.3266 0.4032 0.4831 0.5656-0.6492 0.7333 0.8964 1.0516 1.1941 1.75 0.0509 10.1057 10.1652 0.2284 0.2948-0.3651 0.4391 10.5163 0.5949 0.6743 0.8289 0.9768 1.1127 1.80 0.0487 0.0995 0.1519 0.2052 0.2606 0.3227 0.3878 10.4551 0.5229 0.5916 0.7309 0.8645 1.0009 1.85 0.0472 0.0965 0.1476 0.1996 0.2526 0.3065 0.3610 0.4156 0.4794 0.5485 0.6876 0.8270 0.9623 1.90 0.0451 0.0924 0.1415 0.1915 0.2426 0.2949 0.3479 0.4011 0.4545 0.5105 0.6416 0.7730 0.9005 1.95 0.0425 0.0872 0.1337 0.1812 0.2297 0.2796 0.3304 03815 0.4328 0.4844 0.5875 0.703 1 0.8232 2.00 0.0395 0.0813 0.1247 0.1693 0.2148 0.2618 0.3099 0.3584 0.4073 0.4565 0.5549 0.6615 0.7791 2.05 10.0363 0.0749 0.1152 0.1566 0.1990 0.2429 0.2880 0.3338 0.3800 0.4267 0.5205 0.6216 0.7339 2.10 0.0332 0.0684

-0.1056 0.1439 0.1833 0.2241 0.2662 0.3092 0.3529 0.3973 0.4867 0.5801 0.6862 2.15 0.0320 0.0651 0.0986 0.1320 0.1684 0.2064 0.2457 0.2862 0.3275 03698 0.4553 0.5423 0.6372 2.20 0.0306 0.0625 0.0947 0.1269 0.1591 0.1916 0.2273 0.2657 0.3050 0.3455 0.4-272 0.5101 0.5933 2.25 0.0293 0.0598 0.0908 0.1217 0.1526 0.1838 0.2154 0.2479 0.2853 0.23 0.4014 10.4804 0.5598 2.30 0.0281 0.0573 0.0869 0.1166 0.1463 0.1762 0.2065 0.2371 0.2679 0.3038 0.3777 0.4531 1 0.5291 2.35 0:'0269 0.0549 0.083,4

  • 0.1118 0.1403
0.1690 0.19981.-: -0,22-75 0.2570 ~0.2865 -

0.3561 0.4282.-..,Q..5013.

2.40 0.0258 0.0527 0.0800 0.1074 0.1348 0.1624 0.1904 0.2208 0.2521 0.2843

-0.3507 0.4206 0.4936 2.50 0.0239 0.0488 0.0742 0.0996 0.1258 0.1533 0.1816 0.2110 0.2414 0.2729 0.3381 0.4070 0.4193 2.60 0.0223 0.0455 0.0692 0.0930 0.1169 0.1410 0.1653 0.1899 0.2146 0.2394 0.2888 0.3416 0.4038 2.70 0.0209 0.04'27 0.0650 0.0873 0.1098 0.1326 0.1555 0.1787 0.2021.

0.2256 0.2723 0.3189 0.3651 2.80 0.0196 0.0401 0.0611 0.0822 0.1034 0.1249 0.1467 0.1687 0.1908 0.2131 0.2576 0.3021 0.3464 2.90 0.0184 0.0376 0.0573 0.0773 0.0973 0.1177 0.1383 0.1591 0.1801 0.2013 0.2438 0.2864 0.3289 3.00 0.0172 0.0352 0.0537 0.0724 0.0913 0.1106 0.1301 0.1498 0.16,97 0.1898 0.2303 0.2712 0.3121 3.10 0.0160 0.0328 0.0501 0.0677 0.0854 0.1035 0.1219 0.1406 0.1594 0.1785 0.2171 0.2562 0.2956 3.20 0.0148 0.0304 0.0465 0.0629 0.0796 0.0966 0.1139 0.1314 0.1493 0.1674 0.2040 0.2414 0.2792 3.30 0.0136 0.0280 0.0430 0.0583 0.0738 0.0897 0.1060 0.1225 0.1393 0.1564 0.1912 0.2269 0.2629 3.40 0.0125 0.0258 0.0396 0.0537 0.0681 0.0830 0.0982 0.1138 0.1296 0.1459 0.1788 0.2126 0.2468 3.50 0O.01 14 0.0236~ 0-63 0.0493 0.0627'

-0.0766 0.0908 0.1054, 0.1204 0.1357 0.1668 0.1987. -.

30 3.60 0.0105 0.0215 0.0331 0.0452 0.0576 0.0705 0.0839 0.0976 0.1116 0.12)60 0.1552 0.1850 0.2153 3.70 0.0097 0.0198 0.0304 0.0415 0.0531 0.0650 0.0774 0.0902 0.1033 0.1167 0.1439 0.1718 0.2001 3.80 0.0089 0.0182 0.0280 0.0382 0.0488 0.0599 0.0713 0.0832 0.0953 0.1078 0.1332 0.1591 0.1856 3.90 0.0081 0.0167 0.0257 0.0351 0.0449 0.0550 0.0655 0.0765 0.0878 0.0994 0.1229 0.1470 0.1716 4.00 0.0076 0.0153 0.0235 0.0321 0.0411 10.0504 0.0601 0.0702 0.0806 0.0914 0.1132 0.1355 0.1583 4.10 0.0074 0.0148 0.0219 0.0293-0.0375 0.0461 0.0550 0.0643 0.0739 0.0838 0.1040 0.1247 015 4.0 0.00-72 0.0143 0.0213 0.0281 034 0.21 0.0502 0.588 06.0677 0.0768 0.0954 0.1-013 4.30 0.0030 0.0139 0.0206 0.0273 039 0.46 0.0473 054 0.68 0.0702 0.083 01491012 4.40 0.0067 0.0134 0.0200 0.0264 032 0.393 (0.0459 0.052 I 0.52 006-.79

.90 01 N-

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 18 of 349 Date: 08/27/03 4.50 0.0065 0.0130 0.0193 0.0256 0.0318 0.0381 1 0.0444 0.0508 10.0573 0.0639 0.0773 0.0909 0.1045 4.60 0.0063 0.0125 0.0187 0.0247 0.0308 0.0368 1 0.0430 0.0491 10.0554 0.0618 0.0747 0.0879 0.1012 4.70 0.0061 0.0121 0.0180 0.0239 0.0297 0.0356 0.0415 0.0475 J0.0535 0.0597 0.0722 0.0850 0.0978 4.80 0.0058 0.0117 0.0174 0.0231 0.0287 0.0344 0.0401 0.0459 0.0517 0.0577 0.0698 0.0821 0.0946 4.90 0.0056 0.0113 0.0168 0.0223 0.0277 0:0332 0.0387 0.0443 0.0499 0.0557 0.0674 0.0793 0.0913 5.00 0.0054 0.0109 0.0 162 0.0215 0.0268 0.0320 0.0374 0.0427 0.0482 0.0537 0.0650 0.0765 0.0882 5.10 0.0052 0.0105 0.0156 0.0208 0.0259 0.0309 0.0361 0.0412 0.0465 0.0518 0.0627 0.0739 0.0851 5.20 0.0050 0.0101 0.0151 0.0200 0.0250 0.0299 0.0348 0.0398 0.0448 0.0500 0.0605 0.0713 0.0821 5.40 0.0047 0.0094 0.0140 0.0187 0.0234 0.0280 0.0325 0.0370 0.0417 0.0465 0.0563 0.0663 0.0764 5.60 0.0043 0.0087 0.0131 0.0175 0.0218 0.0261 0.0304 0.0346 0.0389 0.0432 0.0523 0.0617 0.0711 5.80 0.0040 0.0081 0.0122 0.0163 0.0204 0.0244 0.0284 0.0323 0.0363 0.0404 0.0487 0.0574 0.0662 6.00 0.0037 0.0075 0.0114 0.0152 0.0190 0.0228 0.0265 0.0302 0.0339 0.0377 0.0454 0.0534 0.0617 6.20 0.0035 0.0070 0.0106 0.0142 0.0177 0.0213 0.0247 0.0282 0.0317 0.0352 0.0424 0.0498 0.0575 6.40 0.0033 0.0066 0.0099 0.0133 0.0166 0.0199 0.0231 0.0264 0.0296 0.0330 0.0397 0.0465 0.0536 6.60 0.0030 0.0061 0.0093 0.0124 0.0155 0.0186 0.0216 0.0247 0.0277 0.0308 0.0371 0.0436 0.0501 6.80 0.0028 0.0057 0.0087 0.0116 0.0145 0.0174 0.0203 0.0231 0.0260 0.0289 0.0348 0.0408 0.0469 7.00 0.0027 0.0054 0.0081 0.0109 0.0136 0.0163 0.0190 0.0217 0.0244 0.0271 0.0326 0.0383 0.0440 7.20 0.0025 0.0050 0.0076 0.0102 0.0128 0.0153 0.0178 0.0203 0.0229 0.0254 0.0306 0.0359 0.0413 7.40 0.0023 0.0047 0.0071 0.0096 0.0120 0.0144 0.0168 0.0191 0.0215 0.0239 0.0288 0.0337 0.0388 7.60 0.0022 0.0044 0.0067 0.0090 0.0113 0.0135 0.0158 0.0180 0.0202 0.0225 0.0271 0.0317 0.0365 7.80 0.0021 0.0042 0.0063 0.0085 0.0106 0.0127 0.0148 0.0169 0.0190 0.0212 0,0255 0.0299 0.0344 8.00 0.0019 0.0039 0.0060 0.0080 0.0100 0.0120 0.0140 0.0159 0.0179 0.0199 0.0240 0.0282 0.0324 8.50 0.0017 0.0034 0.0052 0.0069 0.0087 0.0104 0.0121 0.0138 0.0155 0.0173 0.0208 0.0244 0.0281 9.00 0.0015 0.0030 0.0045 0.0060 0.0076 0.0091 0.0106 0.0121 0.0136 0.0151 0.0182 0.0213 0.0245 9.50 0.0013 0.0026 0.0040 0.0053 0.0066

- 0.0080 0.0093 0.0106 0.0119 0.0133 1 0.0160 0.0187 0.0215 10.00 0.0011 0.0023 0.0035 0.0047 0.0059 0.0071 1 0.0082 0.0094 0.0105 0.0117 0.0141 0.0166 0.0191 I

Cale Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 19 of 349 Date: 08/27/03

-~~----..

~

Table 6-4c. Soil Seta for M=6.0, Set 3 Median Soil Profile (see) 0.1w 0.2z 0.3g 0.4g 0.59 0.6 0.7 ~

0.8g 0.9g LOPi~J1."

1.

1.68 _

0.01 0.2136 0.3501 0.4397 0.5149 0.5793 0.6258 0.6732 0.7167 0.7697 j0.8424 0.9583 1.0237 1.0393 0.03 0.2231 0.3651 0.4561 0.5323 0.5967 0.6426 0.6822 0.7233 0.7776 f0.8511 0.9680 1.0344 1.0497 0.04 0.2393 0.3875 0.4798 0.5564 0.6206 0.6651 0.7030 0.7410 0.7845 0.8589 0.9768 1.0438 1.0593 0.05 0.2558 0.41 00 0.5085 0.5874 0.6511 0.6962 0.7350 0.7-732 0.8057 0.8683 0.9882 11.055-7 1.0712 0.06 0.2853 10.4546 0.5641 10.6493 0.7162 0.7610 0.7971 0.320 0.8599 0.8818 11.0032 11.0710 1.0864

-0.07 0.3137 0.5077 0.6263 0.7211 0.7957 0.8387 0.8704 0.9002 0.9300 0.9501 11.0194 11.0883 1.1039 0.08 0.3358 0.5477 0.6822 0.7859 0.3625 0.9057 0.9433 0.9800 1.0063 1.0216 11.0552 1.1222 1.1353 0.09 0.3654 0.6005 0.7565 0.8675

-10.9486 1.0029 1.0425 1.0767 1.1000 1.1194 11.13 17 1.1375 i1.1520 0.10 0.3946 0.6528 0.8185 0.9447 1.04'24 1.1000 1.1400 1.1743 11.2014 1.2236 11.2303 1.2217 1.1948 0.11 0.4252 0.7154 0.8983 1.0346 1.1390 1.2061 1.2519 1.2886 1.3115 1.3344 11.3430 1.3285 1.2931 0.12 0.4567 0.7637 0.9608 1.1179 1.2395 1.3131 1.3633 1.4034 1.4291 1.4448 11.4631 1.4440 1.4078 0.13 0.4879 0.8259 1.0520 1.2341 1.3745 1.4527 1.4951 1.5305 1.5638 1.5874 11.6071 1.5863 1.5232 0.14 0.4879 0.839-7 1.0929 1.2891 1.4330 1.5131 1.5605 1.6055 1.6391 1.6620 11.6885 1.6614 1.6042 0.15 0.5106 0.8990 1.1646 1.3692 1.5357 1.6355 1.6887 1.7424 1.7802 1.7860 1.7889 1.8267 1.825!

0.16 0.4698 0.8088 1.0829 1.3497 1.6017 11.8109 1.9681 2.0651 12.1185 2.1376 2.1287 2.1182 2.0988 0.17 0.4364 0.7495 1.0089 1.2392 1.4603 1.6668 1.8362 1.9549 2.0263 2.0504 2.1209 2.1850 2.2180 0.18 0.4784 0.8376 1.1305-1.3817 1.5716 1.6917 1.7968 1.9054 2.040 2.1752 2.3386 2.4104 2.4184 0.19 0.4623 0.7671 1.0847 1.3894 1.6828 1.9582 2.1998 2.3747 2.5015 2.5852 2.6830 2.7649 2.8005 0.20 0.5585 0.8630 I1.1912 1.5126 1.8007 12.0581 2.2953-2.4803 2.6195 2.7082 12.7824 2.8091 2.8033 0.21 0.6735 1.1087 1.3413 1.4909 1.6879 11.9198 2.1222 2.2799 2.3994 2.4766 12.5437

'2.6716 12.6928 0.22 0.6326 1.0781 1.3646 1.5771 1.8081 2.0180 2.1971 2.3360 2.4438 2.5185 12.6101 2.7795 12.8139 0.23 0.5394 0.9943 1.4285 1.7609 2.0337

-2.2530 2.4526

-2.6154 2.7540 2.8617 13.0143 3.1185 3.1500 0.24 0.4829 0.9666 1.3640 1.6826 1.9638 2.2038 2.4211 2.6059 2.7692 2.9016 13.0879 3.2013 13.2292 0.25 0.4797 0.9508 1.3454 1.6851 1.9880 2.2436 2.4674 2.6553 2.8242 2.9667 13.1697 13.2636 13.3095 0.26 0.4712 0.9360 1.3359 1.6805 1.9868 2.2407 2.4651 2.6619 2.8454 3.0018 3.2216 13.3511 13.3765 0.27 0.4948 0.9478 12 '551 1.7143 2.0332 2.3007 2.5393 2.7493 2.9435 3.1053 3.3296 3.4624 13.4885 0.28 0.4810 0.9197

1. 3 223 5 1.6824 2.0001 2.2669 2.5039 2.7122 2.9061 3.0710 3.3080 3.4523 13.4865 0.29 0.4346 0.8637 11.2433 1.5831 1.8869 2.1722 2.4415 2.6816 2.9127 3.1215 3.4460 3.6165 13.6447 0.30 0.3861 0.7685 11.1220 1.4536 1.7274 1.9876 12.2455 2.4882 12.7260 2.9392 3.2666 3.4512 13.4996 0.31i 0.3606 0.6824 0.9969 1.3365 1.6707 1.9457 1 2.1679 2.3444 12.5173 2.7278 3.0619 3.2769 3.3640 0.32 0.3571 0.6713 0.9673 1.2659 1.5595 1.8267 2.0718 2.2977 2.5178 2.7366 13.0996 3.3493 3.4697 0.33 0.3526 0.6632 0.9552 1.2540 1.5486 1.8143 12.0568 2.2806 2.5003 2.7055 3.0575 3.3299 3.4733 0.34 0.3434 0.6468 0.9295 1.2186 1.5040 1.7621 1.9992 2.2216 2.4447 2.6585 3.0383 3.3303 3.4935 0.35 0.3366 0.6389 0.9197 1.2096 1.4980 1.7619 2.0080 2.2457 2.4899 2.7279 3.1572 3.4795 3.6633 0.36 0.3145 0.6049 0.8774 1.1615 1.4485 1.7169 1.9725 2.2220 2.4827 2.7381 3.1944 3.5364 3.7142 0.37 0.3 134 0.5923 0.8123 1.0279 1.2606 1.4'709 1.6745 1.8975
2. 1286 2.3518 2.7690 3.2853 3.6974 0289 0.2989 0.5767 0.8081 1.0156 1.2433 1.4504 1.6409 1.8315 12.0335 2.2363 2.6384 3.1258 3.5900 0.39 0.3081 0.5432 0.7684 0.9694 1.1688 11.3583 1.5302 1.6994 1.8741 2.0448 2.4391 2.9634 3.4123 0.40 0.3207 0.5492 0.7587 0.9593 1.1498 1.3311 1.4935 1.6496 1.8102 1.9649 2.3478 2.8387 13.26,87 0.41 0.3244 0.5612 0,7513

.0.9546 1.132 1.3215 1.4822 1.6349 1.7896 1.9407 2.2310 2.6955 3.1122 0.42 0.3314 0.5882 0.7928 0.9962 1.1942 1.3660 1.5216 11.6676 1.8140 1.9531 2.1913 2.4412

'2.8284 0.43 0.3155 0.5591 0.7530 0.9474 1.1409 1.3132 1.4747 11.6316 1.7967 1.9559 2.2443 2.4904 2.6809 0.44 0.3123 0.5442 0.7301 0.9318 1.1051 1.2663 1.4069 1.5370 1.6669 1.7926 2.0989 2.3680 2.5820 0.45 0.2940 0.5320 0.7552 0.9625 1.1421 1.3057 1.4463 1.5779 1.7098 1.8336 12.0556 2.2432 2.4295 0.46 0.2808 0.5215 0.7466 0.9542 1.1325 1.2908 1.4312 1.5613 1.6918 1.8152 2.0367 2.2264 2.3670 0.47 0.2571 0.4958 I0.7134 0.9171 1.0928 1.2401 1.3758 1.5000 1.6257 1.7449 1.9565 2.1379 2.2710 0.48 0.2451 0.4764 10.6921 0.8966 1.0719 1.2145 1.3455 1.4638 1.5815 1.6939 1.8911 2.0601 12.1841 0.49 0.2446 0.4807 10.7050 0.9156 1.0940 1.2436 1.3699 1.4821 1.5950 1.7001 1.8872 2.0459 2.1641 0.50 0.2501 0.4954 10.7274 0.9423 1.1323 1.2830 1.4016 1.5067 1.6127 1.7127 1.8915 2.0458 2.1614 0.51 0.2474 0.4905 10.7178 0.59362 1.1251 1.2700 1.4267 1.5628 1.6907 1.8063 2.0104 2.1847 2.2881 0.52 0.2277 0.4499 0.6690 0.9049 1.1266 1.3127 1.4679 1.6039 1.7337 1.8521 2.0590 2.2441 2.3581 OM ~fl 2090.

0.4284 0.6.509 0.8755 1.0853 1.2616 1.4108 1.5,446 1.6740 1.7940.,

1.9947 2.1818 2.3035 0.54 0.1982 0.4056 0.6135 0.8227 1.0190 1.1870 1.3325 1.4662 1.5966 1.7182'-

1.9235 2.1009 2.224.4 0.55 0.1887 0.3861 0.5832 0.7822 0.9709 1.1355 1.2821 1.4183 1.5516 1.6763 1.8855 2.0598 12.1831 0.56 0.1837 0.3726 0.5636 0.7567 0.9427 1.1081 1.2584 1.3998 1.5380 1.6665 1.8808 2.0589 12.1808 0.57 0.1822 0.3691 0.5536 0.7459 0.9328 1.1031 1.2596 1.4074 1.5510 1.6836 1.9022 2.0884 12.2086 0.58 0.1813 0.3676 0.5524 0.7355 0.9238 1.0975 1.2584 1.4099 1.5552 1.6883 1.9073 2.1010 2.2192 0.60 0.1701 0.3450 0.5203 0.6952 0.8628 1.0150 1.1690 1.3134 1.4519 1.5795 1.7981 1.9933 2.1175 0.62 0.1628 0.3306 0.4998 0.6706 0.8357 10.9869 1.11297 1.2692 1.4107 1.5502 1.8192 2.0284 2.1553 0.64 0.1553 0.3170 0.4826 0.6525 0.8196; 0.9759 1.1251 1.2712

.4194 1.5650 1.871 2.1224 2.2718 0.66 0.1399 0.28-71 90.44,00 0.5998 10.7590A 0.9106 11.0569 1.011134 1.4863 1.8082 2.0785 2.2514

Caic Number: GEO.HB[P.03.02 Rev Number: 0 Sheet Number: 20 of 349 D ate: 08/27/03 0.68 0.1216 0.2518 10.3865 0.5262 0.66W7 0.8104 1 0.9518 It1.0944 1.2410 1.3875 1.6672 J1.9092 12.0853 0.70 0.1156 0.2253 0.3355 0.4493 0.5686 J0.6943 0.8212 10.9498 -~1.0828 1.2163 1.4796 J1.7471 11.9655 0.72 0.1133 0,2258 0.3371 0.4528 0.5687 0.6793 0.7893 10.9021 I 1.0205 1.1443 1.4030 1.662 1I1.9027 0.74 0.1130 0.2235 0.3298 0.4398 0.5514 0.6590 0.7660 10.8753 10.9906 1.1098 1.3591 j1.6085 11.837R 0.76 0.1207 0.2399 0.3531 0.4649 0.5732 0.6727 0.7676 10.8625 10.9602 1.0600

-1.2591 1.4503 1.6386 0.78 0,1274 0.2539 0.3755 0.4966 0.6147 0.7241 0.8288 0.9330 1.0403 1.1496 1.3706 11.5857 11.7902

0. 80:. 0:281 0.2552

-0:37998>

OI028 0:6245

-~0:7338 0.8479 0.9562.-

1.0675 1.1807

-.14105 11.63355. 1: 18494 0.82 0.1241 0.2465 0.3665 0.4880 0.6080 0.7-214 0.8306 0.9391 1.0496 1.1620 1.3902 1.6146 11.82815 0.84 0.1263 0.2424 0.3465 0.462 1 0.5770 0.6867 0.7930 0.8984 1.0055 1.1144 1.3355 1.5537 1.7628 0.86 0.1313 0.2546 0.3654 0.4694 0.5657 0.6489 0.7509 0.8521 0.9549 1.0592 1.2713

1. 4 81S 1.6R52 0.8 0.1326 0.2592 0.3755 0.4864 0.5900 0.6800 0.7613 0.8377 0.9164 1.0149 1.2171 1.4200 1.618'2 0.90
0. 1320 0.2596 0.3787 0.4938 0.6023 0.6975 0.7838 0.8652 10.9438 1.0189 1.1803 1.3751 1.5664 10.92 0.1310 0.2584 0.3782 0.49.51 0.6063 0.7046 0.7942 0.8789 0.9608 1.0396 11.1885 1.3356 1.5197 0.94 0.1299 0.2563 0.3756 0.4927 0.6047 0.7045 0.7958 0.8824 10.9663 11.0472 11.1996 11.3440 1.4825 0.96 0.1285 0.2535 0.3716 0.4878 0.5996 0.6997 0.7917 0.8791 10.9642 11.0460 1.2004 11.3451 11.4821 0.98 0.1268

.0.2501 0.3666 0.481 5 0.5923 0.6920 0.7838 0.8713 0.9567 1.0389 1.1940 1.3389 1.4739 1.00 0.1246 0.2458 0.3605 0.4736 0.5828 0.6816 0.7727 0.8597 0.9447 1.0268 1.1818 1.3260 1.4594 1.05 0.1181 0.2312 0.3396 0.4465 0.5503 0.6446 0.7321 0.8158 0.8979 0.9774 1.1281 1.2676 1.3946 1.10 0.t176 0.2314.0.3554 0.4333 0.5242 0.6127 0.6962

-0.775f- '0.8541 0.9300 ~-<1:0736 1.2065

.1,3264 1.15 0.1216 0.2352 0.3431 0.4456 0.5410 0.6222 0.6930 0.7663 0.8424 0.9160 1.0562 1.18 60 1.3030 1.20 0.1201 0.2365 0.3460 0.4513 0.5503 0.6355 0.7099 10.7772 0.8471 10.9195 1.0566 1.1837 1.2983 1.25 0.1143 0.2265 0.3319 0.4341 0.5312 0.6163 0.6917 10.7604 0.8273 10.8986 1.0327 1.1561 1.2667 1.30 0.1015 0.2023 0.2977 0.3920 0.4856 10.5691 0.6433 10.7115 10.7796 10.8436 0.9680 1.0920 1.2051 1.35 0.0862 0.1752 0.2634 0.3504 0.4356 0.5151 0.5891 10.6587 0.7250 0.787:5 0.9226 1.0511 1.1683 1.40 0.0823 0.1684 0.2547 0.3403 0.4238 0.5008 0.5727 10.6446 0.7119 0.7744 0.8865 1.0109 1.1278 1.45 0.0738 0.1492 0.2247 0.3000 0.3748 0.4477 0.5184 0.5876 0.6555 0.7222 0.8524 0.9773 1.0925 1.50 0.0705 0.1426 0.2152 0.2876 0.3599 0.4306 0.4994 0.5669 0.6334 0.6986 0.8256 0.9472 1.0590 1.55 0.0678 0.1371 0.2069 0.2766 0.3461 0.4142 0.4806 0.5457 0.6100 0.6730 0.7954 0.9120O 1.0192 1.60 0.0646 0.1308 0.1973 0.2638 0.3301 0.3949 0.4581 0.5202 0.5814 0.6414 0.7578 0.866 -0.9704 1.65 0.0609 0.1234 0.18-61 10.2488 0.3114 0.37225 0.4320) 0.4904 10.5482 0.6049 0.7147 10.8196 10.9166 1.70 0.0569 0.1153 0.1739 0.2326 0.2911 0.3483 0.4040 0.4588 0.5130 0.5664 0.6702 10.7698q 0.8627 1.75 0.0527 0.1069 0.1614 0.2161 0.2707 0.3240 0.3762 0.4275 0.4785 0.5289 0.6275 10.7227 0.12 1.80 0.0488 10.0987 0.1492 0.2000 0.2509 0.3007 0.3495 0.3978 0.4460 0.4938 0.5880 10.6798 0.7675 1.85 0.0469 0.0945 0.1419 0.1892 0.2360 0.2819 0.3269 0.3714 0.4159 0.4615 0.5523 0.6677 0.97 1.90 0.0453 0.0913 0.1373 0.1832 0.2289 0.2737 0.3178 0.3616 0.4099 0.4667 0.5880 0.7175 0.j51 1.95 0.0438 0.088 0.1330 0.1778 0.2224 0.2663 0.3139 0.3666 0.4217 10.4792 0.6012 0.7303 0.8632J 2.00 0.0423 0.0855 0.1290 0.1726 0.2162 0.2591 0.3075 10.3589 0.4126 0.4685 0.5865 0.7109 0.8392 2.05 0.0408 0.0827 0.1248 0.1673 0.2097 0.2517 0.2932 10.3394 0.3900 0.4427 0.5540 0.6720 10.7949 12.10 10.0393 0.0796 0.1204 0.1616 0.2028 0.2437 0.2842 10.3247 0.3655 0.4110 0.5140 0.6234 10.7377 12.15 10.0376 0.0764 0.1157 0.1555 0.1954 0.2349 0.2742 10.3136 0.3533 0.3932 0.4726 0.5597 10.6625 2.20 10.0359 0.0730 0.1107 0.1488 0.1I7 0.2254 0.2634 10.3015 0.3400 0.3787 10.4561 0.5326 10.6262 2.25 0.0341 0.0693' 0.1053 0.1418 0.1786 10.2152 0.2518 10.2886 10.3258 10.3633 10.4384 10.5130 10.6020 2.30 0.0322 0.0655 0.0996 0.1344 0.1694 0.2045 0.2396 0.27:50 0.3108 10.3470 10.4197 10.4923 10.5657 2.35 0.0302 0.0616 0.0938 0.1267 0.1600 0.1935 0.'2271 0.2610 0.2954 10.3302 0.4004 0.4707 0.5403 2.40 0.0282 0.0577 0.0880 0.1190 0.1505 0.1824 0.2144 0.2468 0.2797 0.3131 0.3805 0.4484 0.5158 2.50 0.0245 0.0500 0.0766 0.1040 0.1320 0.1606 0.1895 0.2188 0.2486 0.2788 0.3403 0.4027 0.4656

,2.60 0.0213 0.0436 0.0667 0.0905 0.1150 0.1402 0.1659 0.1919 0.2191 0.2477 0.3067 0.3676 0.4300 2.70 0.0187 0.0376 10.0576 0.0782 0.0994 0.1228 0.1472 0.1724 10.1981 0.2244 0.2788 0.3350 0.3926 2.80 0.0177 0.0355 10.0534 0.0716 10.0899 0.1092 0.1312 0.1539 0.1772 0.2011 0.2506 0.3020 10.3549 2.90 0.0166 0.0335 10.0504 0.0676 0.0850 0.1024 0.1200 0.1377 0.1573 0.1789 0.2239 10.2709 10.3192 3.00 0.0156 0.0315 0.0476 0.0638 0.0802 0.0967 0.1133 0.1300 0.1469 10.1641 0.2004 10.2427 10.2862 3.10 0.014-7 0.0297 0.0449 0.0602 0.0757 0.0913 0.1070 0.1227 0.1387 0.1548 0.1875 0.2208 0.2559 3.20 0.0138 0.0-280 0.0424 0.0569 0.0715 0.0863 0.1011 0.1159 0.1309 0.1461 0.1768 0.2080 0.2395 3.30 0.0131 0.0265 0.0401 0.0538 0.0676 0.0816 0.0956 0.1096 0.1238 0.1381 0.1670_

0.1963 0.'2259 3.40 0.0124 0.0251 0.0379 0.0509 0.0640 0.0772 0.0905 0.1038 0.1172 0.1308 0.1581 0.1858 0.2139 3.50 0.0117 0.0237 0.0359 0.0483 0.0607 0.0733 0.0859 0.0985 0.1113 0.1241 0.1500 0.1764 0.2031 3.60 0.0112 0.0225 0.0341 0.0458 0.0576 0.0696 0.0816 0.0936 0.1057 0.1180 0.1427 0.1679 0.1935 3.70 0.0106 0.0214 0.0324 0.0435 0.0548 0.0661 0.0776 0.0891 0.1007 10.1123 0.1360 10.1601 0.1847 3.80 0.0101 0.0204 0.0308 0.0414 0.0521 0.0629 0.0739 0.0848 0.0959 0.1071 0.1298 10.1530 0.1767 3.90 0.0097 0.0194 0.0294 0.0394 0.0496 0.05-99 0.0704 0.0809 0.0915 0.1022 0.12.39 10.1463 10.1691 4.00 0.0092 0.0185 0.0280 0.0375 0.0472 0.0571 0.0671 O0.071 0.0873 0.0975 0.1184 0.1399 0.1619 4.10 0.0088

-0.0177 0.0266 10.0357 0.0450 0.0544 0.0639 0.0735 0.0832 0.0931 0.1132 0.1338 0.1550 4.20 U0.084 0.0168 10.0254 10.0340 0.04-29 0.0518 0.0609 0.0701 0.0794 0.0888 0.1081 0.1279 0.1482 4.30 0.0080 0.0160 0.0242 10.0324 0.48 009

.51 0.0668 0.0757 0.0848 0.1032 0.1222 0.1417 14.40 10.0076 0.0153 0.0231 10.0309 0.0389 0.0470_

0.0553 i0.0637 10.0722 10.0808 0.0985 0.1167 I0.1353

Calc Number: GEO. HBIP.03.02 Rev Number: 0 Sheet Number: 21 of 349 Date: 08/27103 4.50 0.0072 I 0.0146 0.0220 0.0295 0.0370 0.0448 0.0527 0.0607 I0.068 0.0771 0.0939 01113 0.1290 4.60 0.0069 0.0139 0.0209 0.0281 0.0353 0.0427 0.0502 0.0578 0.0656 0.0734 0.0895 0.1060 0.1229 4.70 0.0065 0.0132 0.0199 0.0267 0.0336 0.0406 0.0478 0.0551 0.0624 0.0699 0.0852 0.1009 0.1170 4.80 0.0062 0.0125 0.0190 0.0254 0.0320 0.0387 0.0455 0.0524 0.0594 0.0665 0.0811 0.0960 0.1112 4.90 0.0059 0.0119 0.0180 0.0242 0.0304 0.0368 0.0433 0.0499 0.0565 0.0633 0.0771 0.0912 0.1057 5.00 0.0056 0.0113 0.0171 0.0230 0.02S9 0.0350 0.0412 0.0474 0.0537 0.0602 0.0732 0.0866 0.1003 5t.10 -

0.0053 0.0107 0.0163 0.0219 0.0275 0.0333" 0.0391 0.0451' 0.01 0572 0:0696 : :O:0822 0.0951 5.20 0.0050 0.0102 0.0155 0.0208 0.0261 0.0316 0.0372 0.0428 0.0485 0.0543 0.0660 0.07S0 0.0901 5.40 0.0045 0.0092 0.0139 0.0187 0.0236 0.0285 0.0335 0.0386 0.0437 0.0489 0.0594 0.0701 0.0809 5.60 0.0041 0.0083 0.0126 0.0169 0.0213 0.0257 0.0302 0.0348 0.0394 0.0440 0.0534 0.0629 0.0726 5.80 0.0037 0.0074 0.0113 0.0152 0.0192 0.0232 0.0272 0.0313 0.0355 0.0397 0.0481 0.0566 0.0651 6.00 0.0033 0.0067 0.0102 0.0137 0.0173 0.0209 0.0246 0.0283 0.0320 0.0358 0.0433 0.0509 0.0586 6.20 0.0030 0.0061 0.0092 0.0124 0.0156 0.0189 0.0222 0.0255 0.0289 0.0323 0.0390 0.0459 0.0528 6.40 0.0029 0.0058 0.0088 0.0119 0.0150 0.0181 0.0211 0.0242 0.0272 0.0301 0.0360 0.0413 0.0477 6.60 0.0026 0.0053 0.0081 0.0109 0.0138 0.0167 0.0195 0.0224 0.0252 0.0280 0.0335 0.03S9 0.0443 6.80 0.0023 0.0047 0.0071 0.0096 0.0122 0.0148 0.0173 0.0199 0.0224 0.0249 0.0299 0.0348 0.0397 7.00 0.0020 0.0041 0.0062 0.0084 0.0106 0.0128 0.0150 0.0173 0.0196 0.0219 0.0265 0.0312 0.0360 7.20 0.0018 0.0037 0.0057 0.0076

. 0.0096 0.0116 0.0137 0.0158 0.0179 0.0200 0.0242 0.0285 0.0330 7.40 0.0017 0:0034 0.0052 0.0070

'-.0088 0.0107 0:0125 0.0144 o:o163 0.0183 0.0222 0.0262 0.0303 7.60 0.0015 0.0031 0.0048 0.0064 0.0081 0.0098 0.0115 0.0132 0.0150 0.0168 0.0204 0.0242 0.0280 7.80 0.0014 0.0029 0.0044 0.0059 0.0074 0.0090 0.0106 0.0122 0.0138 0.0155 0.0189 0.0224 0.0260 8.00 0.0013 0.0027 0.0040 0.0054 0.0068 0.0083 0.0098 0.0113 0.0128 0.0143 0.0175 0.0208 0.0241 8.50 0.0011 0.0023 0.0034 0.0045 0.0057 0.0069 0.0081 0.0093 0.0106 0.0119 0.0146 0.0174 0.0204 9.00 0.0010 0.0020 0.0029 0.0038 0.0048 0.0058 0.0068 0.0079 0.0090 0.0101 0.0124 0.0149 0.0175 9.50 0.0009 0.0017 0.0026 0.0035 0.0043 0.0052 0.0060 0.0069 0.0077 0.0087 0.0107 0.0129 0.0152 10.00 0.0008 0.0016 0.0024 0.0031 0.0039 0.0047 0.0055 0.0062 0.0070 0.0077 0.0094 0.0113 0.0134

Calc Number: GEO.HBLP.03.02 Rev Number: 0 Sheet Number: 22 of 349 Date: 08/27/03 K-Table 6-5a. Soil Spectra for M=7.0, Set 1, Median Soil Profile Per (sec)

I

.Og 0.2g 0.3g 0.4g 0.53 0.6g 0.7R UR 0.9g lOg 1.2e l

1.4a I.6G 0.01 0.1794 0.3249 0.4309 0.5101 0.5778 0.6443 0.7092 0.7655 0.8156 0.3 649 0.9777 1.0547 1.1079 0.03 0.1824 0.3304 0.4380 0.5175 0.5854 0.6519 0.7168 0.7734 0.8232 0.8720 0.9843 1.0600 1.1109 0.04 0.1856 0.3367 0.44491 0.5249 0.5927 0.6593 0.7241 0.7804 0.8302 0.8788 0.9907 1.0650 1.1138 0.05 0.2039 O.3555 0.4626 0.5403 0.6057'l 0.6715 0.7362 0.7918 0.8407

'O.8883' 0.9996

'1.0717 1.1176 0.06 0.2066 0.3664 0.4754 0.5546 0.6212 0.6862 0.7501 0.8056 0.8544 0.9018 1.0117 1.0810 1.1225 0.07 0.1996 0.3567 0.4707 0.5534 0.6234 0.6909 0.7585 0.8155 0.8647 0.9133 1.0239 1.0929 1.1302 0.08 0.2750 0.4482 0.5580 0.6393 0.7020 0.7610 0.8175 0.8648 0.9080 0.9517 1.0532 1.1108 1.1384 0.09 0.2652 0.4456 0.5639 0.6467 0.7099 0.7690 0.8301 0.8802 0.9228 0.9683 1.0736 1.1348 1.15R2 0.10 0.2993 0.4274 0.5283 0.6050 0.6820 0.7531 0.8195 0.8743 0.9223 0.9714 1.0832 1.1480 1.1714 0.11 0.3337 0.5120 0.6322 0.7207 0.7733 0.7996 0.8447 0.8976 0.9478 0.9957 1.1096 1.1760 1.1952 0.12 0.3580 0.5539 0.6900-0.7905 0.8478 0.8816 0.8975 0.9179 0.9709 1.0199 1.1355 1.2017 1.2163 0.13 0.3927 0.6111 j 0.7665 j 0.8793 0.9489 0.9856 1 1.0040 1.0034 J 1.0289 J 1.0783 ) 1.1894 1 1.2488 1.2530 1 0.14 0.4362 0.6841 i 0.8621 1 0.9880 1.0694 1.1145 1 1.1378 1.1374 1 1.1263 1 1.1190 1 1.2258 1 1.2879 1.2925 0.15 0.4483 0.7101 0.8997 1.0427 1.1357 1.1902 i1.2216 1.2254 1.2145 11.2039 1.2338 11.3072 11.3206 0.16 0--.4469 0.7197 0.9273.

1.0813 1.2000.

1.2569 1.2733 1.3193 1.3684 11.3946 41.3925 1.-3060 11.3365 0.17 0.4206 0.6275 0.8062 0.9356 1.0208 1.0815 1.1321 1.2068 1.2706

"'11-3

-1.3600 1.2128' S1.668 0.18 0.4507 0.689S 0.9116 1.0220 1.1007 1.1877 1.2804 1.3644 1.4314 1.4821 1.5378 1.3731 1.2888 0.19 0.4775 0.7154 0.8482 0.9502 1.0396 1.1779 1.2958 1.3815 1.4324 1.4642 1.4295 1.2955 1.3164 0.20 0.4961 0.7511 0.8824 1.0239 1.2245 1.3322 1.3878 1.4716 1.5313 1.5715 1.5759 1.3821 1.3741 0.21 0.5419 0.8007 0.9598 1.1326 1.2764 1.4122 1.4765 1.5014 1.5559 1.6213 1.6712 1.5020 1.4993 0.22 0.5948 0.8817 1.0356 1.1708 1.2863 1.4054 1.5084 1.5532 1.5672 1.5875 1.6245 1.6686 1.6560 0.23 0.5687 1.0150 1.2348 1.3442 1.4 270 1.4884 1.6071 1.6937 1.7151 1.7871 1.8661 1.7505 1.7471 0.24 0.5111 1.0128 1.3190 1.4235 1.4309 1.5055 1.5880 1.6615 1.7240 1.7758 1.7872 1.7396 1.7651 0.25 0.5718 0.9653 1.3174 1.4760 1.5680 1.6137 1.6423 1.6317 1.6485 1.7162 1.7554 1.6005 1.6712 0.26 0.6007 1.0256 1.3677 1.6414 1.7610 1.7942 1.7980 1.7680 1.7209 1.7657 1.8137 1.6152 1.5576 0.27 0.5528 0.9639 1.3564 1.6641 1.7957 1.8269 1.9268 1.9731 1.9605 1.9411 1.942-2 1.7500 1.7646 0.28 0.5222 0.9097 1.2718 1.5865 1.8466 2.0589 2.1998 2.2577 2.2655 2.2845 2.2176 2.0757 2.0689 0.29 0.4926 0.8919 1.2637 1.5899 1.8645 2.0787 2.2270 2.3073 2.3385 2.3765 2.3621 2.2045 -22249 0.30 0.4224 0.8134 1.2219 1.5241 1.7802 1.9418 2.0841 2.1817 2.2382 2.3013 2.3259 2.1304 2.2019 0.31 0.3922 0.7980 1.2700 1.6889 1.9937 2.1884 2.3243 2.4143 2.4631 2.5062 2.4565 2.0923 2.1134 0.32 0.3848 0.7956 1.2638 1.6949 2.0141 2.2227 2.3650 2.4710 2.5553 2.6047 2.6084 2.1968 2.0388 0.33 0.3622 0.6922 1.1180 1.5317 1.8811 2.1441 2.3426 2.4935 2.5959 2.7404 2.8730 2.4734 2.0143 0.34 0.3361 0.6379 0.9597 1.3507 1.6813 1.9367 2.1479 2.4136 2.6235 2.7S29 2.9527 2.6030 2.1062 0.35 0.3148 0.6006 0.8625 1.1223 1.4562 1.7878 2,0976 2.3692 2.5863 2.7550 2.9526 2.6593 2.3440 0.36 0.3320 0.5840 0.8010 1.0859 1.3823 1.6729 1.9720 2.2336 2

2.4481 2.6147 2.8215 2.5990 2.6248 0.37 0.3519 0.6308 0.8518 1.0487 1.2493 1.4788 1.7003 1.9144 2.1021 2.2491 2.5999 2.7960 2.8275 0.38 0.3548 0.6482 0.8886 1.1057 1.3233 1.5454 1.7634 1.9616 2.1479 2.3228 2.6940 2.S706 2.9127 0.39 03431 0.6367 0.8828 1.1054 1.3259 1.5479 1.7626 1.9562 2.1355 2.3039 2.6490 2.8171 2.8921 0.40 0.3253 0.6099 0.8517 1.0691 1.2823 1.4951 1.6987 1.8795 2.0447 2.1991 2.5143 2.6856 2.8067 0.41 0.3142 0.5900 0.8244 1.0340 1.2373 1.4368 1.6259 1.7920 1.9421 2.0833 2.3739 2.5713 2.7453 0.42 0.3191 0.5897 0.8217 1.0279 1.2255 1.4182 1.5995 1.7572 1.8995 2.0339 2.3258 2.5719 2.7872 0.43 0.3499 0.6002 0.8353 1.0444 1.2438 1.4368 1.6186 1.7776 1.9223 2.0605 2.3763 2.6771 2.9095 0.44 0.3699 0.6145 0.8433 1.0561 1.2590 1.4562 1,6419 1.8058 1.9575 2.1058 2.4501 2.7878 3.0235 0.45 0.3697 0.6085 0.8336 1.0481 1.2516 1.4500 1,6376 1.8052 1.9633 2.1174 2.4809 2.8385 3.0728 0.46 0.3475 0.5749 0.8114 1.0237 1.2246 1.4198 1.6059 1.7736 1.9333 2.0892 2.4593 2.8233 3.0576 0.47 0.3092 0.5532 0.7851 0.9935 1.1899 1.3800 1.5616 1.7268 1.8846 2.0393 2.4072 2.7720 3.0083 0.48 0.2827 0.5341 0.7612 0.9655 1.1569 1.3415 1.5173 1.6789 1.8331 1.9861 2.3486 2.7116 2.9530 0.49 0.2740 0.5186 0.7412 0.9418 1.1285 1.3077 1.4782 1.6350 1.7857 1.9355 2.2920 2.6530 2.9019 0.50 0.2672 0.5057 0.7241 0.9212 1.1035 1.2776 1.4432 1.5949 1.7427 1.8890 2.2391 2.5998 2.8546 0.51 0.2615 0.4944 0.7088 0.9027 1.0812 1.2503 1.4110 1.5589 1.7021 1.8457 2.1888 2.5478 2.8076 0.52 0.2566 0.4846 0.6951 0.8860 1.0613 1.2259 1.3817 1.5254 1.6654 1.8052 2.1418 2.4978 2.7615 0.53 0.2524 0.4762 0.6834 0.S715 1.0433 1.2043 1.3559 1.4954 1.6313 1.7683 2.0975 2.4511 2.7179 0.54 0.2487 0.4688 0.6728 0.8583 1.0274 1.1846 1.3323 1.4682 1.6012 1.7348 2.0567 2.4070 2.6761 0.55 0.2453 0.4622 0.6633 0.8464 1.0127 1.1672 1.3116 1.4439 1.5733 1.7038 2.0193 2.3654 2.6363 0.56 0.2420 0.4560 0.6543 0.8353 0.9996 1.1514 1.2926 1.4217 1.5478 1.6756 1.9846 2.3264 2.5984 0.57 0.2388 0.4503 0.6461 0.8251 0.9876 1.1370 1.2756 1.4016 1.5254 1.6505 1.9529 2.2902 2.5632 0.58 0.2359 0.4449 0.63S7 0.8160 0.9767 1.1241 1.2602 1.3838 1.5049 1.6275 1.9237 2.2567 2.5311 0.60 0.2299 0.4345 0.6245 0.7983. [ 0.9821 1.1555 1.2880 1.3679 1.4658 1.5840 1.8689 2.1929 2.4694 0.62 1-0.2232 0.4228

-0.6077 0.8169 1.0321 1.2164 1.3601 1.4506 1.5001 1.5381 1.8126 2.1282 2.4030 0.64 1 0.2159 0.4095 1 0.588 1 0.8026 1 1.0158 1 1.2015 1.3492 1 1.4460 1 1.5032 1.5412 1 1.7605 1 2.0661 2.3390 J 1 0.66 0 0.2095 0.3979 1 0.5725 1 0.7508 1 0.9551 1 1.1361

-1.2835 1 1.3841 1 1.4469 1.4901 1 1.7242 1 2.0222 2.2928

Calc Number: GEO.HBIP.03.02-Rev Number: 0 Sheet Number: 23 of 3 49

______~~ ~~~Date:

08/27/03 0.68 0.2046 0.3897 0.5616 017200 0.8689

.02 IjI1jj.187IE1.2911 i.3834 ]1.4885 11.7050 1-9972?

2.2676 0.70 0.2008 0.3835 0.5538 0.7114 0.8558 0.9891 1.11931 1.2638

-1.3837 1.4864 j1.6910 1.9777 -2.2493 0.72 0.1967 0.3768 0.5454 0.7019 0.8457 0.9786 11.1019 1.2151 1.3339 1.4367 ]1.6699 1.9513 2.2237 0.74 0.1920 0.3688 0.5349 0.6895 0.831t9 0.9636 11.0853 1.1951 1.2994 1.4043 1.6421 1.9177 J2.1899 0.76 0.1870 0.3602 0.5234 0.6754 0.8157 0.9457 1.0658 1.1737 1.2763 1.3882 1.6383 1.8898 2.1525 0.78 0.1821 0.3517 0.5119 0.6613 0.7995 0.9277 1.0461 1.1768 1.3235 1.4619 1.7237 1.9856 J2.2312 0.80 0:1 774

'~-D3435

-0.5008

.0.647,8 0.7839

"~104. -

1.0274 1.1325'-.

-1.2319.

1.3501..-1.591g.:

L.L83.13 j2.0838.

0.82 0.1729 0.3356 0.4902 0.6347 0.7688 0.8936 1.0093 1.1132 1.2115 1.3102 1.5295 1.7847 12.0526 0.84 0.1685 0.3280 0.4798 0.62-20 0.7541 0.8773 0.9916 1.0945 1.1917 1.2891 1.5046 1.7556 2.0223 0.86 0.1644 0.3207 0.4699 0.6100 0.7403 0.8619 0.9150 1.0769 1.1733 L.2697 1.4818 1.7287 1.9943 0.88 0.1607 0.3141 0.4.611 0.5992 0.7279 0.8484 0.9604 1.0616 1.1572 1.2531 1.4624 1.7056 1.9706 0.90 0.1573 0.3081 0.4531 0.5896 0.7171 0.8367 0.9480 1.0488 1.1441 i1.2409 1.4464 1.6872 1.9517 0.92 0.1540 0.3023 0.4456 0.5807 0.7073 0.8260 0.9369 1.0376 1.1328 1.2314 1.4332 1.~67715 1.9366 0.94 0.1504 0.2963 0.4377 0.5716 0.69172 0.8155 0.9260 1.0266 1.1219 1.2198 1.4217 1.6560 1.9212 0.96 0.1496 0.2894 0.4289 0.5613 0.6859 0.8036 0.9138 1.0144 1.1097 1.2047 1.4075 1.6376 1.9023 0.98 0.1484 0.2815 0.4187 0.5496 0.6730 0.7897 0.8994 0.9999 1.0950 1.1896 1.3877 1.6146 1.8772 1.00 0.1474 0.2786 0.4074 0.5365 0.6584 0.7738 0.8827 0.9826 1.0773 1.1713

.1.3647 1.5864 1.8451 1.05 0.1456 0.2757 0.3984 0.5127 0.6178 10.7288 0.8341 0.9315 1.0241 1.1154 1.2984 1.5059 1.7445

-1.10 0.1422 -0.2712 10.3926 0O5053 0.6080 0.O4-4 -- t607 9 73 0.8864

-0.97,50 1.0654 1:'2425 1.4367 1.6472.

1.15 0.1456 0.2757 10.3921 0.5012 0.6022 0.6972 0.7876 0.8731 0.9576 1.0441 1.2123 1.3908 1.5894 1.20 0.1488 0.2839-0A4073 0.5257 0.6290 0.7189 0.7957 0.8631 0.9452 1.0293 1.1930 1.3600 1.5504 1.25 0.1417 0.2789 10.4111 0.5344 0.6447 0.7442 0.8332 0.9083 0.9727 1.0322 1.1705 1.3292 1.5089 1.30 0.1342 0.2689 0.4025 0.5300 0.6465 0.7530 0.8496 0.9334 1.0068 1.0748 1.1939 1.3040 1.4647 1.35

0. 1272 0.2588 10.3892 0.5135 0.6276 01324 0.8281 0.9123 0.9874 1.0579 1.1852 1.3025 1.4413
  • 1.40 0.1196 0.2425 0.3639 0.4794 0.5855 0.6833 0.7733 10.8533 0.9258 0.9945 1.1429 1.2861 1.4192 1.45 0.1092 0.2207 0.3308 0.4357 0.5322 0.6235 0.7135 0.7971 0.8763 0.9544 1.1072 1.2499 1.3822 1.50 0.0982 0.1989 0.3012 0.4027 0.4996 0.5918 0.6793.

0.7612 0.8393 0.9161 1.0666 1.2089 1.3415 1.55 0.0926 0.1878 0.2846 0.3812 0.4744 0.5742 0.6722 0.7597 0.8345 0.8995 1.0328 1.1750 1.3085 1.60 0.0884 0.1861 0.2912 0.4023 0.5157 0.6269 0.7313 0.8238 0.9025 0.9-704 1.0822 i1.1576 1.2872 1.65 0.0869 0.1833 0.2872 0.3970 0.5089 0.6182 0.7207 0.8117 0.8888 0.9548 1.0603 1.1458 1.2746 1.70 0.0811 0.1656 0.2566 0.3556 0.4567 10.5560 0.6495 0.7331 0.8135 0.8865 1.0430 1.1864 1.3046 1.75 0.0779 0.1596 10.2439 0.3299 0.4156 10.5030 0.6086 0.7135 0.8119 0.9008 1.0581 1.2097 1.3382 1.80 0.0745 0.1531 10.2345 0.3178 0.4014 0.4857 0.5858 0.6873 0.7876 0.8838 1.0600 1.2152 1.3472 1.85 0.0707 0.1457 0.2237 0.3038 0.3846 0.4716 0.5709 -0.6720 0.7739 0.8718 1.0492 1.2025 1.3257 1.90 0.0665 0.1375 0.2115 0.2879 0.3653 0.4516 0.5467 0.6434 0.7386 0.8329 1.0082 1.1641 1.2908 1.95 0.0621 0.1286 0.1984 0.2707 0.3444 0.4213 0.5098 0.5999 0.6888 0.7755 0.9463 1.1003 1.2259 2.00 0.0575 0.1194 0.1848 0.2531 0.3238 0.3974 0.78 0.5498 0.6305 0.7130 0.8708 11.0275 1.1750 2.05 0.0529 0.1110 0.1735 0.2398 0.3088 0.3800 0.4531 0.5278 0.6029 0.6769 0.8336 0.9897 1.1399 2.10 0.0493 0.1047 0.1644 0.2276 0.2936 10.3618 0.4318 0.5037 0.5761 0.6476 0.7976 0.9518 1.0988 2.15 0.0477 0.0983 0.1548 0.2148 0.2775 0.34-24 0.4092 0.4780 0.5475.0.6163 0.7589 0.9080 1.0499 2.20 0.0461 0.0921 0.1449 0.2015 0.2608 0.32-23 0.3858 0.4513 0.5179 0.5840 0.7155 0.8590 0.9973 2.25 0.0444 0.0889 0.1349 0.1880 0.24.40 0.3021 0.3623 0.4247 0.4884 0.5517 0.6743 0.8060 0.9679 2.30 0.0427 0.0857 0.1288 0.1747 0.2273 0.2822 0.3393 0.3987 0.4596 0.5200 0.6375 0.7561 10.8970 2.35 0.0410 0.0825 0.1242 0.1663 0.21 13 0.2632 0.3173 0.3738 0.4316 0.4891 0.6013 0.7158 0.8281 2.40 0.0394 0.0794 0.1198 0.1605 0.2015 0-.2455 0.2965 10.3499 0.4047 0.4592 0.5659 0.6763 0.7868 2.50 0.03 63 0.0736 0.1114 0.1497 0.1884 0.2275 0.2670 0.3071 0.3538 0.40215 0.4992 0.6051 0.7166 2.60 0.0334 0.0682 0.1038 0.1401 0.1768 0.2138 0.2510 0.2889 0.3273 0.3682 0.4637 0.5627 0.6665 2.70 0.0308 0.0633 0.0970 0.1313 0.1660 0.2010 0.2362 0.2720 0.3082 0.3445 10.4279 0.5214 0.6191 2.80 0.0284 0.05899 0.0906 0.1230 0.1558 0.1888 0.2222 0.2560 0.2903 0.3246 0.3922 0.4797 0.5727 2.90 0.0263 0.0549 0.0845 0.1150 0.1459 0.1772 0.2087 0.2408 0.2732 0.3056 0.3698 0.4385 0.5272 3.00 0.0245 0.0510 0.0788 0.1074 0.1365 0.1660 0.1958 0.2261 0.2567 0.2875 0.3484 0.4093 0.4821 3.10 0.0227 0.0474 0.0733 0.1000 0.1274 0.1551 0.1832 0.2119 0.2409 0.2700 0.3279 0.3862 0.4449 3.20 0.0210 0.0439 0.080 0.0930 0.1186 0.1447 ~0.1712 0.1982 0.2257 0.2532 0.3083 0.3641 0.4'200 3.30 0.0193 0.046 0.0629 0.0862 0.1102 0.1346 0.1596 10.1851 0.2111 0.2372 0.2896 0.3431 10.3962 3.40 0.0178 0.074 0.0581 0.0798 0.1022 0.1251 0.1485 0.1726 0.1973 0.2221 10.2718 0.3229 0.3735 3.50 0.0163 0.0344 0.0536 0.0737 0.0946 0.1160 0.1381 0.1609 0.1844 0.2079 0.2549 0.3034 0.3515 3.60 0.0150 0.0316 0.0494 0.0680 0.0874 0.1075 0.1283 0.1501 0.1723 0.1945 0.2388 0.2846 0.3302 3.70 0.0137 0.0290 0.0454 0.0627 0.0808 0.0997 0.1194 0.1399 0.1608 0.1817 0.2233 0.2665 0.3097 3.80 0.0125 0.0266 0.0417 0.0577 0.0746 0.0925 0.1110 0.1303 0.1500 0.1696 0.2086 0.2492 0.2900 3.90 0.0120 0.0244 0.0383 0.0531 0.0691 0.0858 0.1032 0.1213 0.1397 0.1581 0.1946 0.2327 0.2711 4.00 0.0115 0.0233 0.0353 0.0490 0.0639 0.0796 0.0959 0.1128 0.1300 0.1472 0.1813 0.2171 0.2532 4.10 0.0110 0.0222 10.0337 0.0456 0.0592 0.0738 0.0890 0.1048 0.1209 0.1370 0.1688 0.2023 026 4.20 0.0103 0.0209 10.0318 0.0430 0.0548 0.0684 0.0825 0.0973 0.1123 0.1273 10.1571 0.1884 0.2202 4.30 0.0096 0.0194 0.0297 0.0402 0.0510 0.0634 0.0765 0.0903 0.1044

0. 11 84 ~0. 1461 0.1754 0.2052 4.40 1 0.0093 0.0186 10.0280 10.0374 0.0474 0.0587 0.0-710 0.0838 0.0969 0.1100 10.1359 0.1632 0.1912

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 24 of 349 Date: 08/27/03 4.50 0.0089 0.0179 0.0270 0.0360 0.0451 0.0544 I0.0658 0.0778 0.0900 10.1022 0.1264 1 0.1519 0.1781 4.60 0.0086 0.0172 0.0259 0.0347 0.0434 0.0522 0.0611 0.0722 0.0837 l 0.0950 0.1176 l 0.1414 0.1659 4.70 0.0086 0.0176 0.0269 0.0365 0.0461 0.0557 0.0652 0.0746 0.08381 0.0929 0.1104 10.1317 0.1546 4.80 0.0090 0.0194 0.0231 0.0381 0.0483 0.0586 0.0689 0.0791 0.0892 0.0992 0.1186 0.1374 0.255X 4.90 0.0090 0.0184 0.0281 0.0333 0.0487 0.0593 0.0700 0.0807 0.0914 0.1020 0.1228 0.1431 0.1631 5.00 0.0086 0.0176 0.0269 0.0367 0.0469 0.0574 0.0680 0.0787 0.0896 0.1004 0.1216 0.1427 0.1635 5:10' 0.0079

'0-.-O61 0.0O47 0.0337 0.0432 0.0530 0.0&3I-0.0734 0.0840

'0.0945 0.1152 0-- 1363 0.1571 5.20 0.0069 0.0142 0.0217 0.0297 0.0381 0.0469 0.0561 0.0656 0.0754 0.0852 0.1046 0.1247 0.1449 5.40 0.0063 0.0128 0.0196 0.0266 0.0340 0.0417 0.0497 0.0579 0.0663 0.0748 0.0917 0.1092 0.1273 5.60 0.0059 0.0118 0.0178 0.0238 0.0299 0.0359 0.0423 0.0496 0.0571 0.0647 0.0799 0.0960 0.1128 5.80 0.0054 0.0109 0.0165 0.0212 0.0278 0.0334 0.0391 0.0448 0.0505 0.0563 0.0682 0.0809 0.0942 6.00 0.0051 0.0102 0.0154 0.0207 0.0259 0.0311 0.0364 0.0417 0.0471 0.0525 0.0635 0.0754 0.0878 6.20 0.0047 0.0095 0.0144 0.0193 0.0242 0.0292 0.0342 0.0392 0.0442 0.0491 0.0593 0.0704 0.0820 6.40 0.0044 0.0089 0.0135 O.O182 0.0230 0.0278 0.0327 0.0376 0.0424 0.0473 0.0569 0.0666 0.0767 6.60 0.0041 0.0083 0.0126 0.0169 0.0212 0.0257 0.0302 0.0348 0.0394 0.0440 0.0531 0.0624 0.0718 6.80 0.0039 0.0078, 0.0118 0.0158 0.0198 0.0238 0.0279 0.0319 0.0360 0.0402 0.0486 0.0577 0.0673 7.00 0.0036 0.0073 0.0111 0.0148 0.OI86 0.0224 0.0262 0.0300 0.0338 0.0377 0.0456 0.0542 0.0632 7.20 0.0034 0.0069 0.0104 0.0140 0.0175 0.0210 0.0246 0.0282 0.0318 0.0355 0.0429 0.0510 0.0595 7.40 ' 0.0032 0:0065 0.0098 0.0131-0:U165 0.0198

'0.0232 0.0265 0.0300 0.0334 - 0.0404' "U.C47W 0.0560 7.60 0.0030 0.0061 0.0092 0.0124 0.0155 0.0187 0.0219 0.0250 0.0283 0.0315 0.0381 0.0453 0.0529 7.80 0.0029 0.0058 b.0087 0.0117 0.0147 0.0177 0.0207 0.0237 0.0267 0.0298 0.0360 0.0428 0.0500 8.00 0.0027

.0.0055 0.0083 0.0111 0.0139 0.0167 0.0195 0.0224 0.0252 0.0281 0.0341 0.0405 0.0473 8.50 0.0024 0.0048 0.0072 0.0097 0.0122 0.0146 0.0171 0.0196 0.0221 0.0246 0.0298 0.0354 0.0414 9.00 0.0021 0.0042 0.0064 0.0086 0.0107 0.0129 0.0151 0.0173 0.0195 0.0217 0.0263 0.0313 0.0365 9.50 0.0019 0.0037 0.0057 0.0076 0.0095 0.0115 0.0134 0.0154 0.0173 0.0193 0.0234 0.0278 0.0325 10.00 0.0017 0.0034 0.0051 0.0068 0.0085 0.0103 0.0120 0.0137 0.0155 0.0173 0.0209 0.0248 0.0290

t Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 25 of 3 )49 Date: 08/27/03 Table 6-5b. Soi Spectra for M=7. 0, Se 2, Median Soil Profile Per (5cec) 0.lg 0.2R 0.3S 0.4g 0.5t!

0.6g 0.7g 0.8g 0.9g L.0e 1.2e 1.4si 1.6a 0.01 0.1513 0.2976 0.4145 0.5054 0.5705 0.6605 0.7282 0.7810 0.8244 0.8591 0.9173 1.0405 1.1324 0.03

0. 1545 0.3040 0.4229 0.5142-0.5-795 0.6646 0.7329 0.7862 0.8300 0.8648 0.9229-1.0468 1.1382 0.04 0.1622 0.3098 0 40:

.0.5232 0.58830 0.6700 0.7377 0.7909 0.8347 0.8698 0.9278 1.0524 1.1437 0.05 0.1780 0.3246 0.4455" 0.5379 0.04 066

.47 078

.41 087

.9328 1.0590.1t1 0.06 0.1923 0.3193 0.4496 0.5518 0.61 83 0.6698 0.7262 0.7865 0.8362 0.8763 0.9355 1.0638 1.1579 0.07 0.2116 0.3572 0.4597 0.5614 0.6555 0.7436 0.8040 0.8493 0.8863 0.9139 0.9507 1.0753 1.1672 0.08 0.2403 0.3809 0.4905 0.5774 0.6467 0.6991 0.7570 0.8165 0.8645 0.9043 0.9471 1.0778 1.1742 0.09 0.2869 0.4743 10.6237 0.7247 0.7790 0.8168 0.8407 0.8609 0.8810 0.9097 1.0192 1.1253 1.2058 0.10 0.3002 0.5114 0.6540 0.7664 0.8222 I0.8492 0.8687 0.8794 0.9040 0.9397 1.0307 1.1577 1.2440 0.11 0.3578 0.5431 0.7168 0.8897 1.0221 11.1054 1.1505

1. 1744 1.1855 1.1849 1.1229 1.1402 1.2305 0.12 0.4066 0.6364 0.7767 0.9126 1.0512 11.1667 1.2347 1.2767 1.3034 1.3157 1.2654 11.2618 1.3222 0.13 0.3713 0.5908 0.7647 0.8617 0.8892 11.0119 1.0951 1.1552 1.1947 1.2186 1.2513 1.3380 1.3960 0.14 0.4822 0.8080 0.9398 1.0456 1.1114 11.1355 1.1180 1.1678 1.2171 1.2504 1.2589 1.2792 1.3563 0.15 0.4648 0.7103 0.8550 1.0139 1.1596 11.2546 1.2946 1.3201 1.3481 1.3895 1.4755 1.4637 1.3630 0.16

.0.5048 0.7517 0.8.75,4..

1.0843 1.2582 1.3506 1.3915 J..4714,4L. 01.5250 1.5578 1.5540 1.4740 1.3862 0.17 0.4839 0.8572 1.0783 1.2489 1.3228 1.3934 1.4814 1.5494 1.5933 1.6284'

6-4-29 1.5634.

4-6 0.18 0.4789 0.9192 1.2572 1.4796 1.5909 1.6894 1.7732 1.8314 1.8435 1.8095 11.7234 1.6676 1.6105 0.19 0.4418 0.7880 1.0747 1.2691 1.3792 1.4748 1.5642 1.6214 1.6642 1.7514 11.8282 1.8696 1.8427 0.20 0.4842 0.7561 1.0141 1.2055 1.3326 1.4475 1.5434 1.6109 1.6354 1.7342 11.9046 1.9769 1.9792 0.21 0.5194 0.8040 1.0509 1.2797 1.4480 1.5955 1.7126 1.7918 1.8166 1.8709 11.9558 1.9803 12.0037 0.22 0.5845 0.9508 1.1753 1.2761 1.4208 1.5831 1.7084 1.7890 1.8703 1.9499 2.0599 2.1386 12.1913 0.23 0.5415 1.0089 1.3203 1.4554 1.5588 1.6763 1.8019 1.9363 2.0561 2.1421 2.1800 2.1587 2.1729 0.24 0.5733 1.0188 1.4102 1.6248 1.7094 1.8251 1.9430 2.0766 2.2043 2.3060 2.3963

.2.3988 2.4323 0.25 0.5643 0.9997 1.3240 1.6381 1.8473 1.9303 2.0543 2.1286 2.1661 2.2707 2.3863 2.4358 2.5044 0.26 0.5379 0.9884 1.4186 1.8058 2.1087 2.3095 2.4449 2.5332 2.5664 2.5267 2.2440 2.3256 2.4478 0.27 0.5306 1.0001 1.4571 1.8585 2.1612 2.3800 2.5363 2.6519 2.71 13 2.7001 2.4334 2.2159 2.2009 0.28 0.5145 0.9982 1.4597 1.8632 2.1796 2.4246 2.00 27480 2.8264 2.8256 2.5652 2.3804 2.3751 0.29 0.4863 0.9804 1.4195 1.8188 2.1615 2.4279 2.6307 2.7804 2.8641 2.8715 2.6275 2.4399 2.4545 0.30 0.4613 0.9119 1.3376 1.6772 1.9584 2.2296 2.4295 2.5788 2.6696 2.6974 2.6677 2.5910 2.5585 0.31 0.4232 0.8440 1.2268 1.6410 2.0292 2.3213 2.5358 2.6971 2.8136 2.8580 2.7200 2.6918 2.6903 0.32 0.3715 0.7926 1.2451 1.7045 2.1452 2.52227 2.7883 2.9799 3.1069 3.1568 3.1981 3.0628 2.9797 0.33 0.3597 0.7151 1.1550 1.6842 2.1929 2.5943 2.8890 3.1025 3.2438 3.4277 3.5543 3.4359 3.3754 0.34 0.3279 0.6438 1.0302 1.4478 1.9070 2.2863 2.5830 2,Z847 3.1517 3.3637 3.5337 3.4536 3.4271 0.35 0.3107 0.6175 0.9912 1.3878 1.7960 2.1696 2.5014 12.8076 3.0825 3.3034 3.5085 3.4486 3.4408 0.36 0.3217 0.6033 10.9238 1.2996 1.6916 2.0571 2.3813 2.6827 2.9584 3.1860 3.4151 3.3861 3.4721 0.37 0.325 1 0.6137 0.9089 1.1946 1.5586 1.91 19 2.2290 2.5235 2.7972 3.0287 3.2670 13.3288 3.4914 0.38 0.3126 0.5871 0.8652 1.1316 1.4127 1.7046 1.9792 2.2425 2.4930 2.7207 3.0895 13.3060 3.4838 0.39 0.3214 0.5991 0.8763 1.1419 1.3798 1.6515 1.9130 2.1670 2.4089 2.6309 2.9970 3.3650 3.5578 0.40 0.3239 0.6030 0.8823 1.1524 1.3980 1.6141 1.8413 2.0830 2.3168 2.5303 3.1247 3.5476 3.7744 0.41 0.3366 0.6027 0.8511 1.1150 1.3587 1.5713 1.7814 2.0150 2.2411 2.4893 3.324 3.5990 3.8566 0.42 0.3523 0.6464 0.8830 1.0594 1.2865 1.4942 1.72 11 11.9488 2.1702 2.3806 3.0253 3.5206 13.8062 0.43 0.3652 0.6785 10.9401 1.1429 1.2838 1.4202 1.6385 1.8577 2.0729 2.2770 12.7905 3.3465 3.7029 0.44 0.3812 0.6846 10.9605 1.1804 11.3398 1.4536 1.5458 1.7432 1.9474 2.1435 2.5990 3.1098 3.4907 0.45 0.4046 0.7057 0.9562 1.1856

.1.3565 1.4802 1.5733 1.7136 1.8932 2.0887 2.5454 2.9587 3.3089 0.46 0.4099 0.7163 0.9523 1.1772 1.3554 1.4859 1.5827 1.7149 1.8849 2.0693 2.5028 2.9065 3.2545 0.47 0.3821 0.6669 0.9256 1.1629 1.3462 1.4809 1.5806 1.7252 1.8875 2.0628 2.4-763 2.8700 3.2175 0.48 0.3316 0.6248 0.9044 1.1428 1.3295 1.4675 1.5852 11.7388 1.8961 2.0641 2.4605 2.8447 3.1934 0.49 0.3086 0.6047 0.8810 1.1176 1.3059 1.4461 1.6002

-1.7523 1.9063 2.0684 2.4499 2.8266 3.1739 0.50 0.3015 0.5820 0.8512 1.0849 1.2742 11.4515 1.6082 1.7598 1.9114 2.0681 12.4355 12.8041 3.1532 0.5 1 0.2980 0.5780 0.8347 1.0667 1.2700 11.4474 1.6054 1.7561 1.9045-2.0558 2.4095 2.7704 3.1158 0.52 0.2921 0.5690 0.8233 1.0534 1.2550 1.4333 1.5908 1.7404 1.8867 2.0344 2.3739 2.7231 3.0647 0.53 0.2846 0.5567 0.8074 1.0349 1.2350 1.4129 1.5709 1.7199 1.8632 2.0058 2.3316 2.6704 3.0043 0.54 0.2767 0.5431 0.7897 1.0144 1.2132 1.3907 1.5495 1.6976 1.8388 1.9778 2.2900 2.6160 2.9439 0.55 0.2688 0.5293 0.7721 0.9942 1.1922 1.3702 1.5297 1.6773 1.8165 1.9519 2.2518 2.5658 12.8873 0.56 0.2617 0.5169 0.7568 0.9774 1.1757 1.3554 1.5161 1.6635 1.8008 11.9328 2.2208 2.5245 12.8394 0.57 0.2557 0.5074 0.7454 0.9662 1.1706 1.4192 1.6270 1.7900 1.9142 2.0060 12.1976 2.4918 12.8013 0.58 0.2505 0.4995 0.7370 0.9725 1.2470 1.5079 1.7252 J1.8963 2.0265 2.1224 2.2565 2.4596 2.7647 0.60 0.2380 0.4791 0.7399 1.0204 1.3069 1.5770 1.8028 1.9814 2.1171 2.2163 2.3976 2.6452 2.8756 0.62 0.2173 0.4412 0.6-763 0.9379 1.2079 1.4652 1.6823 1.8554 2.0438 2.2279 2.5652 2.8559 3.1397 0.64 0.1889 0.3859 0.5823 0.8130 1.0686 1.3369 1.5929 j1.8235 2.0336 2.2191 2.5585 2.8633 3.1730 0.66 0.181.4 10.3644 10.5604 0.77-740 1.0061 1.2509 1.4876 1.7039 1.8988 2.0737 2.3938 2.6930 3.0059

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 26 of 349 Date: 08/27/03 0.68 0.1698 10.3400 0.52 11 0.7149

- 0.9221 1.1401 1.3524 1.5484 1.7269 1.894 2.1932 2.48S4 l 2.8010

-0T70-10.1628 0.3253 0.4974 0.6798 0.8722 1.0747 1.2737 1.4605 1.6343

_ 1.7959 1 2.1065 2.4146 1 2.7364 0.72 0.1610 0.32171 0.4915 0.6710 0.8595 1.0581 1.2560 [1.4451 1.6245 11.7954 12.1282 t 2.4576 2.7969 0.74 0.1583 0.316510.4841 0.6618 0.8487 1.0461 1.2456 1.4398 16273 1.8078 2.1624 2.5092 2.X624 0.76 0.1511 0.3021 0.4622 0.6337 0.8157 1.0091 1.2072 1.4024 1.5939 1.7803 2.1473 2.5031 2.8617

, 0.78

, 0.14424 0.2777 0.4199 0.5776 0.7476 0.9304 1.1202 1.3102 1.4983 1.6835 2.0507 2.402.5 2.7542

-0.80 0.1361 I 0.2619- 'I 0.3961 1 03317 A 0:6649 1 0.8164 I 0.9776 L.1529 -1 1.3288. I 1.5040 I 1.8547-l 2.11882 I 2.5163 I....

0.82 0.1427 0.2683 0.3867 0.5009 0.6129 0.7547 0.8932 1.0265 1.1560 1.2832 1.5991 1.9460 2.2753 0.84 0.1499 0.2860 0.4067 0.5147 0.6263 0.7555 0.8897 1.0222 1.1541 1.2897 1.6393 2.0101 2.3695 0.86 0.1592 0.3064 0.4396 0.5601 0.6608 0.7513 0.8545 0.9879 1.1217 1.2572 1.5369 1.8460 2.1967 0.88 0.1723 0.3344 0.4841 0.6220 0.7404 0.8480 0.9539 1.0606 1.1664 1.2688 1.4632 1.6678 1.9334 0.90 0.1781 0.3477 0.5068 0.6551 0.7851 0.9039 1.0204 1.1372 1.2532 1.3661 1.5801 1.7939 2.0299 0.92 0.1774 0.3478 0.5095 0.6621 0.7978 0.9227 1.0443 1.1662 1.2876 1.4064 1.631S 1.850S 2.0854 0.94 0.1732 0.3379 0.4973 0.6488 0.7852 0.9111 1.0335 1.1557 1.2781 1.3982 1.6269 1.8456 2.0749 0.96 0.1744 0.3282 0.4791 0.6269 0.7612 0.8855 1.0058 1.1262 1.2465 1.3649 1.5926 1.8077 2.0291 0.98 0.1739

'0.32S8 0.4687 0.6068 0.7386 0.8608 0.9788 1.0966 1.2144 1.3313 1.5568 1.7683 1.9331 1.00 0.1728 0.3279 0.4683 0.5978 0.7197 0.8401 0.9562 1.0718 1.1880 1.3033 1.5281 1.7385 1.9491 1.05 0.1626 0.3108 0.4459 0.5702 0.6773 0.7792 0.8890 0.99s0 1.1079 1.2186 1.4397 1.6470 1.8466

,. -Io 0.1528 0o.29

-0.4230 0.541t' 1-6-516 0.7608 0.8655 0,9685

'1.0723 1.1775 1.3910-1.5926 1.7821 1.15 0.1710 0.3256 0.4649 0.5890 0.7056 0.8105 0.9154 1.0183 1.1202 1.2228 1.4333 1.63S4 1.S323 1.20 0.1737 0.3378 0.5000 0.6543 0.7920 0.9160 1.0306 1.1379 1.2393 1.3350 1.5102 1.6608 1.8035 1.25 0.1645 0.3293 0.4895 0.6442 0.7853 0.9141 1.0339 1.1465 1.2533 1.3551 1.5444 1.7104 1.8661 1.30 0.1513 0.3043 0.4545 0.6006 0.7360 0.8609 0.9779 1,0881 1.1928 1.2928 1.4801 1.646S 1.8021 1.35 0.1380 0.2780 0.4169 0.5532 0.6813 0.8008 0.9133 1.0194 1.1202 1.2162 1.3961 1.5571 1.7063 1.40 0.1277 0.2581 0.3883 0.5172 0.6400 0.7555 0.8648 0.9680 1.0656 1.15_ 2 1.3294 1.4819 1.6227 1.45 0.1231 0.2503 0.3781 0.5055 0.6282 0.7441 0.8534 0.9639 1.0693 1.1691 1.3516 1.5071 1.6463 1.50 0.1203 0.2492 0.3825 0.5180 0.6531 0.7839 0.9086 1.0260 1.1365 1.2402 1.4266 1.5822 1.7207 1.55 0.1183 0.2457 0.3778 0.5125 0.646S 0.7759 0.8977 1.0114 1.1175 1.2162 1.3906 1.5317 1.6557 1.60 0.1019 0.2125 0.3267 0.4430 0.5583 0.6687 0.7727 0.8696 0.9647 1.0621 1.2356 1.3704 1.4738 1.65 0.0892 0.1850 0.2849 0.3881 0.4931 0.5964 0.6959 0.7928 0.9048 1.0140 1.2196 1.3956 1.5366 1.70 0.0762 0.1588 0.2473 0.3416 0.4436 0.5518 0.6633 0.7744 0.8839 0.9906 1.1899 1.3567 1.4865 1.75 0.0700 0.1449 0.2245 0.3088 0.3988 0.4931 0.5898 0.6861 0.7867 0.8913 1.1056 1.3124 1.4893 1.80 0.0625 0.1317 0.2067 0.2873 0.3759 0.4703 0.5680 0.6669 0.7666 0.8668 1.0681 1.2616 1.4328 1.85 0.0607 0.1273 0.1988 0.2748 0.3570 0.4441 0.5345 0.6265 0.7199 0.8147 1.0079 1.2031 1.3821 1.90 0.0586 0.1229 0.1918 0.2651 0.3445 0.4286 0.5162 0.6053 0.6961 0.7884 0.9769 1.1660 1.3438 1.95 0.0559 0.1172 0.1828 0.2527 0.3284 0.4087 0.4924 0.5778 0.6649 0.7536 0.9354 1.1187 1.2916 2.00 0.0526 0.1103 0.1722 0.2380 0.3093 0.3851 0.4642

,0.5451 0.6278 0.7121 0.8860 1.0623 1.2293 2.05 0.04S8 0.1025 0.1600 0.2214 0.2879 0.358 0.4329 0.5089 0.5868 0.6665 0.8318 1.0009 1.1617 2.10 0.0456 0.0945 0.1470 0.2036 0.2653 0.3311 0.4001 0.4712 0.5443 0.6194 0.7763 0.9383 1.0931 2.15 0.0435 0.0902 0.1393 0.1909 0.2460 0.3039 0.3680 0.4345 0.5032 0.5741 0.7230 0.8780 1.0265 2.20 0.0414 0.0858 0.1327 0.1819 0.2345 0.2898 0.3472 0.4058 0.4663 0.5330 0.6733 0.8203 0.9620 2.25 0.0393 0.0816 0.1262 0.1731 0.2232 0.2761 0.3311 0.3872 0.4447 0.5034 0,6256 0.7642 0.8985 2.30 0.0372 0.0774 0.1199 0.1645 0.2124 0.2630 0.3155 0.3694 0.4245 0.4810 0.5981 0.7195 0.8376 2.35 0.0353 0.0735 0.1139 0.1564 0.2021 0.2505 0.3008 0.3524 0.4053 0.4595 0.5722 0.6892 0.8035 2.40 0.0335 0.0698 0.1082 0.1488 0.1924 0.2386 0.2868 0.3363 0.3870 0.4390 0.5473 0.6599 0.7702 2.50 0.0302 0.0630 0.0978 0.1345 0.1742 0.2164 0.2604 0.3057 0.3521 0.3999 0.4994 0.6034 0.7056 2.60 0.0271 0.0565 0.0878 0.1210 0.1569 0.1951 0.2351 0.2763 0.3186 0.3621 0.4532 0.5486 0.6428 2.70 0.0241 0.0503 0.0783 0.1080 0.1401 0.1745 0.2106 0.2478 0.2861 0.3256 0.4083 0.4954 0.5816 2.80 0.0238 0.0481 0.0729 0.0989 0.1265 0.1554 0.1870 0.2204 0.2548 0.2903 0.3651 0.4441 0.5224 2.90 0.0240 0.0488 0.0743 0.1007 0.1286 0.1581 0.1887 0.2196 0.2507 0.2819 0.3446 0.4077 0.4702 3.00 0.0242 0.0485 0.0728 0.0970 0.1229 0.1513 0.1810 0.2113 0.2420 0.2731 0.3359 0.3997 0.4630 3.10 0.0242 0.0488 0.0736 0.0986 0.1233 0.1476 0.1716 0.1955 0.2227 0.2521 0.3122 0.3734 0.4341 3.20 0.0224 0.0453 0.0687 0.0924 0.1162 0.1398 0.1633 0.1867 0.2103 0.2343 0.2842 0.3367 0.3923 3.30 0.0194 0.0396 0.0602 0.0813 0.1026 0.1240 0.1453 0.1666 0.1882 0.2102 0.2562 0.3049 0.3552 3.40 0.0165 0.0337 0.0514 0.0694 0.0878 0.1067 0.1258 0.1447 0.1636 0.1823 0.2206 0.2623 0.3067 3.50 0.0150 0.0307 0.0469 0.0634 0.0803 0.0974 0.1144 0.1312 0.1477 0.1641 0.1994 0.2404 0.2830 3.60 0.0152 0.0305 0.0461 0.0620 0.0782 0.0945 0.1107 0.1270 0.1433 0.1614 0.2001 0.2413 0.2835 3.70 0.0149 0.0298 0.0453 0.0611 0.0774 0.0940 0.1107 0.1274 0.1441 0.1609 0.1954 0.2330 0.2732 3.80 0.0148 0.0296 0.0443 0.0589 0.0737 0.0887 0.1042 0.1203 0.1369 0.1539 0.1889 0.2246 0.2601 3.90 0.0141 0.0283 0.0424 0.0565 0.0708 0.0854 0.1004 0.1160 0.1321 0.1487 0.1832 0.2187 0.2543 4.00 0.0130 0.0262 0.0395 0.0527 0.0659 0.0795 0.0936 0.1081 0.1232 0.1389 0.1717 0.2060 0.2403 4.10 0.0119 0.0241 0.0364 0.0487 0.0610 0.0734 0.0862 0.0993 0.1128 0.1270 0.1575 O.1897 0.22 4.20 0.0107 0.028

.0555 0.0669 0.0786 0.0906 0.1029 0.1157 0.1431 0.1727 0.2029

,7;

- -F --

'I 1

4.30 i 0.0101 0.0199 1 0.0298

{ 0.0397 0.0500 1 0.0603 0.0651 0.0418 1 0.0930 6 0.1046 1 0.1293 1

4.0763 1 6.5839

--~~~.09 I 0.029 I 0.39 I6 0.050 I 0.60 I%- 0.71 0.0818 I 0.93 I 0.04 I 0.29 I 0.56 I 0.1839

-fiP 4.40 0.0095 O.018SS 0.0281 0.0374 0.0466 0.F0558 0.0651 1 0.0744 6.0.S6 0.0940 0.116i3 0.40 0.1659

Catc Number: GEO. HB IP.03.02 Rev Number: 0 Sheet Number: 27 of 349 Date: 08/27/03 4.50 0.0090 0.0178 l 0.0267 0.0355 1 0.0442 0.0530 0.0624 0.0721 0.0819 l 0.0919 0.1123 0.1335 0.1547 4.60 0.0086 0.0170 1 0.0254 0.0339 0.0422 0.0508 0.0601 0.0696 0.0792 0.0891 0.1093 0.1303 0.1516 4.70 0.0082 0.0163 0:0244 0.0325 0.0405 0.0485 0.0566 0.0648 0.0738 0.0831 0.1023 0.1225 0.1430 4.80 0.0079 0.0157 0.0235 0.0313 0.0391 0.0468 0.0546 0.0624 0.0702 0.0778 0.0940 0.1125 0.1314 4.90 0.0077 0.0152 0.0228 0.0303 0.0378 0.0453 0.0529 0.0605 0.0680 0.0754 0.0903 0.1063 0.1222 5.00 0.0074 0.0148 0.0221 0.0294 0.0367 0.0440 0.0514 0.0587 0.0660 0.0733 0.0884 0.1043 0.1202 5:10 -

0.0072 0.0144' 0.0215 0.0286 0.0357- 0.0428 0.0500' 0.0571-0.0643 0.0713 0.0856 0.1006 -0O:160 5.20 0.0070 0.0139 0.0209 0.0278 0.0347 0.0416 0.0486 0.0556 0.0626 0.0695 0.0834 0.0981 0.1128 5.40 0.0066 i0.0131 0.0197 0.0262 0.0327 0.0393 0.0459 0.0525 0.0591 0.0657 0.0786 0.0911 0.1036 5.60 0.0062 0.0123 0.0184 0.0245 0.0306 0.0368 0.0430 0.0492 0.0555 0.0617 0.0739 0.0158 0.0977 5.80 0.0057 0.0114 0.0170 0.0227 0.0284 0.0341 0.0398 0.0457 0.0515 0.0573 0.0687 0.0799 0.0911 6.00 0.0052 0.0104 0.0156 0.0208 0.0260 0.0312 0.0365 0.0419 0.0472 0.0526 0.0632 0.0736 0.0839 6.20 0.0047 0.0094 0.0141 0.0188 0.0235 0.0283 0.0331 0.0379 0.0428 0.0477 0.0574 0.0669 0.0764 6.40 0.0045 0.0089 0.0130 0.0174 0.0216 0.0258 0.0298 0.0340 0.0384 0.0427 0.0515 0.0601 0.0687 6.60 0.0044 0.0086 0.0129 0.0173 0.0216 0.0258 0.0299 0.0339 0.0378 0.0416 0.0489 0.0558 0.0627 6.80 0.0042 0.0084 0.0127 0.0170 0.0212 0.0254 0.0295 0.0334 0.0374 0.0412 0.0486 0.0557 0.0627 7.00 0.0040 0.0081 0.0122 0.0164 0.0205 0.0246 0.0286 0.0325 0.0363 0.0401 0.0475 0.0545 0.0616 7.20 0.0038 0.0077 0.0116 0.0156 0.0196 0.0235 0.0273 0.0311 0.0348 0.0385 0.0457 0.0526 0.0596 7.40

'0.003 0.0072 0.0109

0.0147 0.0 15" 0;0222

'0.0258 0.0294 0.0330 0.0365' 00434 0.0501 0.0568 7.60 0.0033 0.0067 0.0102 0.0137 0.0172 0.0207 0.0242 0.0276 0.0309 0.0343 0.0409 0.0473 0.0537 7.80 0.0030 0.0062 0.0094 0.0127 0.0160 0.0192

- 0.0225 0.0256 0.0288 0.0319 0.0381 0.0442 0.0503 8.00 0.0028 0.0057 0.0086 0.0117 0.0147

.0.0177 0.0207 0.0237 0.0266 0.0295 0.0355 0.0419 0.0483 8.50 0.0025 0.0051 0.0077 0.0103 0.0130 0.0157 0.0185 0.0214 0.0243 0.0271 0.0329 0.0388 0.0446 9.00 0.0024 0.0048 0.0071 0.0095 0.0119 0.0145 0.0171 0.0198 0.0224 0.0252 0.0307 0.0363 0.0419 9.50 0.0023 0.0045 0.0067 0.0089 0.0111 0.0133 0.0154 0.0176 0.0197

_ 0.0219 0.0263 0.0312 0.0362 10.00 0.0020 0.0039 0.0058 0.0078 0.0097 0.0116 0.0135 0.0154 0.0174 0.0193 0.0232 0.0272 0.0314

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 28 of 349 Date: 08/27/03 Table 6-5c. Soil Spectra for M=7.0, Set 3, Median Soil Profile (Sec 0.1k 0.2g 0.3 I

0.4g 0.5 O.6g 0.7g 0.8_g 0.9 Lk 1.2I II 1

.6 0.01 0.1824 0.3100 0.4193 10.50520.5813 0.6524 0.7176 0.7741 0.8217 0.8668

.4 0

.9809 10.059 0.03 0.1866 0.3165 0.4269 0.5131 0.5893 0.6601 0.7252 0.7817 0.8291

.0.738 0.9502095.0 10 i.0 005004 8

0.04 01962 1 03263 1 04373 05229 I 0.5983 1 0.6686 1 0.7333 1 0-7893 0.8361 1 0.8804 1 0.9560 I 0.991X 1.0156 1 J

4 4

0.05 01923 1 0.9421 1 04477 0.5326 1 0.6069 1 0.6778 1 0.7429 1 0.7984 0.8448 I 0.8s8s 1 0-9639 F 0.9979 I0213 I

0.06 0.2204 0.3580 0.4697 0.5532 0.6282 0.6994 0.7631 0.8164 0.8606 0.9028 0.9750 1.0070 1.0292 0.07 0.2701 0.3697 0.4662 0.5562 0.6368 0.7102 0.7747 0.8297 0.8740 0.9158 0.9869 1.0190 1.0396 0.08 0.2759 0.4438 0.5226 0.5976 0.6754 0.7456 0.8078 0.8596 0.9018 0.9410 1.0075 1.0358 1.0532 0.09 0.2805 0.4772 0.5670 0.5978 0.6797 0.7542 0.8188 0.8738 0.9168 0.9564 1.0229 1.0505 1.0667 0.10 0.2923 0.5152 0.6095 0.6475 0.7091 0.7837 0.8507 0.9055 0.9466 0.9836 1.0486 1.0735 1.0864 0.11 0.2969 0.5523 0.6929 0.7366 0.7772 0.8379 0.9010 0.9506 0.9850 1.0192 1.0793 1.1013 1.1106 0.12 0.4102 0.6176 0.7127 0.7616 0.8136 0.8577 0.8848 0.9415 0.9838 1.0221 1.0925 1.1180 1.1279 0.13 0.4793 0.7484 0.8740 0.8996 0.8773 0.8509 0.9223 0.9783 1.0209 1.0587 1.1254 1.1479 1.1551 0.14 0.4891 0.7954 0.9427 0.9803 0.9687 0.9287 0.9380 0.99170 1.0390 1.0768 1.1465 1.1717 1.1799 0.15 0.4492 0.7478 10.8962 0.9439 1.0259 1.0656 1.0518 1.0306 1.0341 1.0749 1.1513 1.1831 1.1945

.0.16 0.4773

.0.7368 0.8431 0.9579

.1.0878 1.142L.

1.1-12 1.1287 1.1111.

1.0749 1.1303 1.1745 1.1954 0.17 0.4925 0.7760 0.9913 1.1100 1.2128 1.3162-1.3954 -

1.4476 1.4516 1.4141 1.2770 1.2940 1.2911 0.18 0.4179 0.8498 1.1366 1.2891 1.4002 1.4952 1.5710 1.6207 1.6235 1.5859 1.4405 1,4382 1.4125 0.19 0.4396 0.7477 1.0704 1.2378 1.3348 1.4058 1.4656 ;1.5113 1.5240 1.5038 1.5055 1.5001 1.4695 0.20 0.5189 0.8407 1.0409 1.1518 1.2937 1.4013 1.4436 1.4736 1.4853 1.4716 1.5225 1.5257 1.4984 0.21 0.5994 0.9792 1.2310 1.3879 1.4765 1.5787 1.7010 1.7487 1.7314 1.6678 1.5241 1.5282 1.5024 0.22 0.6116 1.0115 1.3090 1.5052 1.6242 1.6814 1.8014 1.8789 1.8757 1.8125 1.6297 1.4610 1.4358 0.23 0.5782 1.0100 1.3408 1.5538 1.6823 1.7442 1.7421 1.7617 1.7226 1.6389 1.6158 1.4869 1.4794 0.24 0.5891 1.0609 1.4215 1.6496 1.7928 1.8653 1.8750 1.8185 1.7682 1.7943 1.7699 1.6063 1.5858 0.25 0.5823 1.0712 1.4432 1.6852 1.8458 1.9440 1.9727 1.9449 1.9107 1.9149 1.8955 1.7353 1.6301 0.26 0.5532 1.0347 1.4082 1.6659 1.8514 1.9700 2.0195 2.0202 1.9974 1.9868 1.9779 1.8269 1.6713 0.27 0.5303 1.0089 1.3934 1.6739 1.8852 2.0260 2.0929 2.1159 2.1021 2.1051 2.1091 1.9622 1.7554 0.28-0.5586 0.9982 1.3495 1.6495 1.9192 2.1424 2.2787 2.3192 2.2902 2.2276 2.2195 2.0S72 1.8833 0.29 0.5024 0.8991 1.2593 1.5697 1.8141 2.0592 2.2112 2.2479 2.1939 2.2323 2.2748 2.1568 1.9623 0.30 0.4316 0.9091 1.2580 1.4859 1.7347 1.9352 2.0736 2.1336 2.1849 2.2453 2.3097 2.2098 2.0301 0.31 0.4151 0.8530 1.1810 1.3S02 1.6494 1.8701 2.0324 2.1258 2.1795 2.2517 2.3342 2.2567 2.0890 0.32 0.4080 0.7293 1.0431 1.4516 1.8367 2.1519 2.3910 2.5443 2.6143 2.6148 2.4630 2.2986 2.1432 0.33 0.4014 0.7160 1.0856 1.4877 1.8814 2.2193 2.4914 2.6792 2.7739 2.7809 2.6205 2.3578 2.2133 0.34 0.3973 0.7090 0.9937 1.3518 1.7158 2.0451 23273 2.5341 2.6756 2.7413 2.6531 2.4283 2.2980 035 0.3914 0.6985 0.9739 1.2266 1.5764 1.911

. 2.2154 2.4617 2.6251 2.7044 2.6427 2.4842 23664 0.36 0.3847 0.6856 0.9572 1.1969 1.5031 1.8520 2.1794 2.4421 2.6048 2.6681 2.5834 2.5513 2.4503 0.37 0.3795 0.6759 0.9463 1.1858 1.4215 1.7120 2.0466 2.3237 2.5053 2.6199 2.6680 2.6499 2.5599 0.38 0.3735 0.6701 0.9272 1.1646 1.4038 1.6547 1.9688 2.2512 2.4739 2.6289 2.6930 2.7438 2.6829 0.39 0.3764 0.6773 0.9399 1.1599 1.3608 1.5873 1.8242 2.0443 2.2492 2.4173 2.8059 2.8766 2.8184 0.40 0.3753 0.6763 0.9384 1.1600 13620 1.54S2 1.7319 1.9504 2.1331 2.2904 2.6647 2.7450 2.6975 0.41 0.3719 0.6700 0.9307 1.1498 13500 1.5350 1.7070 1.8592 2.0200 2.1820 2.4863 2.6265 2.6408 0.42 0.3682 0.6624 0.9179 1.1325 1.3287 1.5098 1.6795 1.8294 1.9324 2.0642 2.3905 2.5656 2.6146 0.43 0.3664 0.6557 0.9068 1.1170 1.3090 1.4867 1.6521 1.8000 1.9026 1.9902 2.3047 2.5225 2.6076 0.44 0.3635 0.6466 0.8910 1.0962 1.2840 1.4583 1.6228 1.7712 1.8731 1.9621 2.2264 2.4856 2.6076 0.45 0.3511 0.6209 0.8544 1.0507 1.2317 1.4121 1.5873 1.7470 1.8632 1.9554 2.1819 2.4125 2.5675 0.46 0.3295 0.5863 0.8306 1.0476 1.2500 1.4417 1.6232 1.7894 1.9129 2.0125 2.2544 2.4723 2.5863 0.47 0.3536 0.6411 0.8582 1.0368 1.2401 1.4331 1.6162 1.7847 1.9117 2.0154 2.2617 2.4775 2.5866 0.48 0.3632 0.6757 0.9099 1.0714 1.2206 1.4043 1.5864 1.7530 1.8796 1.9842 2.2264 2.4340 2.5365 0.49 0.3572 0.6754 0.9211 1.0805 1.2264 1.3798 1.5581 1.7227 1.8482 1.9512 2.1876 2.3970 2.4841 0.50 0.3401 0.6505 0.8983 1.05S7 1.1796 1.3659 1.5422 1.7039 1.8281 1.9301 2.1620 2.3568 2.4526 0.51 0.3102 0.6084 0.8491 1.0089 1.1692 13533 1.5280 1.6875 1.8113 1.9130 2.1428 2.3366 2.4339 0.52 0.2801 0.5626 0.7184 0.9603 1.1507 1.3316 1.5046 1.6627 1.7855 1.8874 2.1160 2.3093 2.4088 0.53 0.2691 0.5131 0.7376 0.9365 1.1231 1.3012 1.4719 1.6284 1.7505 1.8523 2.0794 2.2711 2.3714 0.54 0.2615 0.4986 0.7166 0.9341 1.1392 1.2938 1.4395 1.5939 1.7154 1.8168 2.0406 2.2292 2.3288 0.55 0.2546 0.4859 0.7303 0.9855 1.1989

'1.3624 1.4798 1.5681 1.6891 1.7896 2.0094 2.1946 2.2929 0.56 0.2492 0.4768 0.7387 0.9942 1.2102 1.3781 1.5015 1.5799 1.6718 1.7711 1.9880 2.1711 2.2691 0.57 0.2453 0.4702 0.7289 0.9808 1.1963 1.3660 1.4925 1.5761 1.6575 1.7557.

1.9707 2.1528 2.2517 0.58 0.2415 0.4642 0.7098 0.9556 1.1685 1.3377 1.4646 1.5552 1.6405 1.7381 1.9517 2.1336 2.2339 0.60 0.2331 0.4495 0.6533 0.8702 1.0677 1.2280 1.3527 1.4827 1.5983 1.6954 1.9069 2.0880 2.1906 0.62 0.2252 0.4356 0.6340 0.8149 0.9865 1.1503 1.3059 1.4490 1.5640 1.6605 1.8689 2.0488 2.1532 1 0.64 0.2183 1 0.4234 1 0.6179 1 0.7957 1 0.9645 1 1.1386 1 1.2966 1 1.4203 I 1.5322 1.6272 1 1.8333 I 2.0133 2.1206_

11

-"t 0.2107 1 0.4096 1 0.5990 1 0.7721 1 0.9367 1 1.0948 l 1.2538 l 1.3800 I1 1.4900 1 1.5835 1 1.7878 I 1.9683 I 2.0786

Calc Number: GEO.H-BIP.03.02 Rev Number: 0 Sheet Number: 29'of 3 49

~~ ~~~Date:

08/27/03 0.68 0.2030 0.3954 0.3788 0.7470 0.906s 1.0597 1.2045 1.3372 1.4461 ]1.5407 1.7461 1 1.9271 2.0399 0.70--

--. 1970 0.384-2 0.5631 0.7-276 0.89 1.0339 1.1765 1.3084 1.4186 ]1.5151 11.7216 11.9033

'2.0179 0.72 0.1922 0.3756 0.5517 0.71383.62 1.0170 1.1594 1.2918 1.4034 j1.5011 1.7088 1.R909 2.0059 0.74 0.1871 0.3665 0.5394 0.6993 0.8523 1.0001 1.1419 1.2739 1.3861 1.4843 1.6905 1.8717 1.9874 0.76 0.1811 0.3556 0.5245 0.6813 0.8315 0.9772 1.1172 1.2479 1.3593 1.4571 1.6605 1.8406 1.9593 0.78 0.1749 0.3441 0.3085 0.6617 0.8088 0.9516 1.0890 1.2176 1.3276 1.4248 1.6259 1.8059 1.9272 01 0.1693 0.3356-

-0.4938 0.6434."Or1873 0.9274 r.106t-5-- t1-892 1.2987...1-3956 1.5962.-L,-7779 1.9032 0.82 0.1640 0.3238

.. 0.4801 0.6267 0.7679 0.9058 1.0393 1.1650 1.2746 1.3724 1.5745 1.7585 1.R871 0.84 0.1623 0.3134 0.4657 0.6093 0.7481 0.8843 1.0166 1.1416 1.2520 1.3512 1.5555 1.-7416 1.8724 0.86 0.1703 0.3076 0.4486 0.58836 0.7249 0.8588 0.9896 1.1139 1.2253 1.3266 1.5460 1.7365

1. 85 18 0.88 0.1756 0.3206 0.4462 0.5640 0.6967 0.8279 0.9566 1.0795 1.1922 1.3071 1.5597 1.7622 1.8891 0.90 0.1780 0.3288 0.4603 0.5712 0.6759 0.7936 0.9199 1.0419 1.1662 1.2988 1.5537 1.7641 1.9020 0.92 0.1778 0.3319 0.4679 0.5826 0.6877 0.7931 0.9047 1.0237 1.1507 1.2794 1.5315 1.7445 1.8903 0.94 0.1754 0.3306 0.4690 0.5865 0.6931 0.7970 0.9032 1.0139 1.1327 1.2552 1.4991 1.7099 1.8602 0.96 0.1716 0.3257 0.4647 0.5836 0.6914 0.7951 0.8985 1.0035 1.1 148 1.2303 1.4628 1.6683 1.8195 0.98 0.1669 0.3187 0.4570 0.5763 0.6847

-0.7884 0.8902 0.9917 1.0973 1.2066 1.4274 11.6253 1.7755 1.00 0.1619 0.3109 0.4477 0.5668 0.6755 0.7791 0.8802 0.9795 1.0808 1.1851 1.3950 1.5851 1.7333 1.05 0.1510 0.2931 0.4257 0.5432 0.6515 0.7548 0.8547 0.9510 1.0464 1.1426 1.3323 1.5057 1.6494 1.10 0.1588 0:5(169 !'-U04397 0.5518 0.63M1 0.7419.o:8:ft9 0.9233 1.0152 1.1068 1.2844: 'I4(~-

1.5876 1.15s

0. 1631-0.3170 0.4570 0.5759 0.6815 0.7784 0.8671 0.9455 1.0053 1.0723 1.2431 1.3974 1.5364 1.20 0.1586 0.3093 0.4484 0.5676 0.6737 0.7717 0.8626 0.9433 1.0077 1.0573 11.2123 1.3613 1.4969 1.25 0.1485 0.2909 0.4249 0.5421 0.6475 0.7450 0.3356 0.9173 0.9854 1.0398 11.1895 1.3348 1.4683 1.30 0.1366 0.2709 0.4008 0.5184 0.6249 0.7227 0.8129 0.8942 0.9645 1.0227 1.1705 1.3129 1.4454 1.35 0.1293 0.2574 0.3810 0.4941 0.5980 0.6947 0.7845 0.8661 0.9394 1.0138 1.1589 1.2951 1.4246 1.40 0.1192 0.2386 0.3549 0.4635 0.5659 0.6637 0.7565 0.8423 0.9258 1.0025 1.1439 1.2740 1.3978 1.45 0.1085 0.2183 0.3304 0.4382 0.5399 0.6367 0.7284 I0.8144 0.8973 0.9736 1.113-2 1.2391 1.3573 1.50 0.1019 0.2054 0.3082 0.4088 0.5052 0.5970 0.6875 0.7741 0.8553 0.9306 1.0684 1.1911 134 1.55 0.0945 0.1907 0.86 0.3794 0.4698 0.5585 0.6453 0.7287 0.8077 0.8816 1.0171 1.1369 1.2466 1.60 0.0876 0.1767 0.2659 0.3529 0.4382 0.5281 0.6283 0.7225 0.8087 0.8828 10.9891 1.0848 1.1917 1.65 0.0816 0.1648 0.2485 0.3381 0.4418 0.5465 0.6487 0.7441 0.8302 0.9027 11.0048 1.0538 1.1467 1.70 0.0768 0.1557 0.2355 0.3304 0.4300 0.5305 0.6282 0.7189 0.7995 0.8661 0.9560 1.0108 1.1148 1.75 0.0733 0.1494 0.2264 0.3031 0.3921 0.4828 0.5707 0.6520 0.7236 0.7816 0.8752 10.9917 1.0954 1.80 0.0706 0.1448 0.2199 0.2947 0.3693 0.4440 0.5182 0.5911 0.6779 0.7635 0.9138 1.0169 1.0846 1.85 0.0685 0.1410 0.2143 0.2876-0.3608 0.4343 0.5077 0.5800 0.6513 0.7340 0.8765 0.9730 1.0769 1.90 0.0664 0.1371 0.2087 0.2803 0.3520 0.4243 0.4968 0.5686 0.6399 0.7098 0.8440 0.9637 1.0674 1.95 0.0641 0.1327 0.2022 0.2719 0.3420 0.4128 0.4841 10.5551 0.6260 0.6959 0.8302 0.9495 1.0526 2.00 0.0614 0.1275 0.1941 0.2622 0.3302 0.3992 0.4689 0.5386 0.6085 0.6777 0.8109 0.9290 1.0492 2.05 0.0584 0.1216 0.1861 0.2511I 0.3167 0.3834 0.4511 0.5189 0.5872 0.6551 0.7858 0.9230 1.0549 2.10 0.0551 0.1151 0.1767 0.2389 0.3017 0.3658 0.4309 0.4963 10.5625 0.6284 0.7656 0.9162 1.0485 2.15 0.0516 0.1081 0.1666 0.2257 0.2857 0.3467 0.4089 0.4715 0.5350 0.5985 0.7506 0.8980 1.0283 2.20 0.0480 0.1010 0.1561 0.2121 0.2689 0.3268 0.3858 0.4452 0.5058 0.5711 0.7238 0.8688 0.9967 2.25 0.0444 0.0938 0.1455 0.1982 0.2518 0.3064 0.3620 0.4183 0.4760 0.5447 0.6928 0.8313 0.9583 2.30 0.0416 0.0868 0.1350 0.1844 0.2346 0.2860 0.3384 0.3915 0.4484 0.5129 -0.6543 0.7897 0.9180 2.35 0.0401 0.0803 0.1247 0.1708 0.2178 0.2660 0.3178 0.3729 0.4310 0.4913 0.6139 0.7485 0.8775 2.40 0.0387 0.0776 0.1163 0.1576 0.2021 0.2526 0.3045 0.3575 0.4132 0.4711 0.5874 0.7092 0.8360 2.50 0.0358 0.0722 0.1087 0.1448 0.1830 10.2291 0.2768 0.3257 0.3771 0.4305 0.5393 0.6449 0.7488 2.60 0.0332 0.0671 0.1012 0.1353 0.1692 0.2063 0.2501 0.2952 0.3425 0.3918 0.4927 0.5912 0.6851 2.70 0.0307 0.0623 0.0942 0.1261 0.1580 0.1900 0.2255 0.2666 0.3099 0.3550 0.4480 0.5395 0.6279 2.80 0.0285 0.0578 0.0876 0.1175 0.1474
0. 1715 D.2076 0.2396 0.2791 0.3203 10.4058 0.4910 0.5755 2.90 0.0265 0.0537 0.0815 0.1095 0.1377 0.1660 0.1944 0.2226 0.2511 0.2879 10.3667 0.4473 0.5321 3.00 0.0246 0.0500 0.0760 0.1023 0.1288 0.1555 0.1824 0.2092

-0.2364 0.2638 0.3343 0.4139 0.4972 3.10 0.0228 0.0466 0.0710 0.0957 0.1207 0.1460 0.1715 0.1971 0.2230 0.2493 0.3097 0.3853 0.4651 3.20 0.0213 0.0435 10.0665 0.0898 0.1135 10.1375 0.1617 0.1861 0.2109 0.2360 0.2868 0.3583 0.4339.

3.30 0.0198 0.0408 0.0624 0.0845 0.1070 10.1298 0.1528 0.1761 0.1998 0.2238 0.2717 0.3320 0.4030 3.40 0.0185 0.0383 0.0588 0.0797 0.1010 10.1228 0.1448 0.1670 0.1896 0.2125 0.2584 10.3061 0.3725 3.50 0.0174 0.0360 0.0554 0.0753 0.0956 10.1163 0.1374 0.1586 0.1802 0.2020 0.2460 0.2891 032 3.60 0.0163 0.0339 0.0523 0.0713 0.0906 0.1104 0.1305 0.1508 0.1714 0.1923 0.2344 0.2757 0.3168 3.70 0.0154 0.0320 0.0495 0.0675 0.0860 0.1049 0.1242 0.1436 0.1633 0.1833 0.2235 0.2631 0.3023 3.80 0.0146 0.0303 0.0468 0.0640 0.0817 0.0999 0.1183 0.1369 0.1557 0.1748 0.2133 0.2512 0.2886 3.90 0.0138 0.0287 0.0444 0.0609 0.0779 0.0953 0.1129 0.1306 0.1486 0.1668 0.2035 0.2399 0.2756 4.00 0.0132 0.0273 0.0423 0.0581 0.0743 0.0909 0.1078 0.1247 0.1419 0.1592 0.1943 0.2291 0.2633 4.10 0.0125 0.0260 0.0403 0.0554 0.0709 0.0868 0.1029 0.1191 0.1354 0.1520 0.1856 0.2189 0.2516 4.20 0.0119 0.0248 0.0384 0.0528 0.0676 0.0828 0.0982 0.1136 0.1293 0.41 017 0.2092 0.2406 4.30 0.0113 0.0236 0.0366 0.0503 0.0645 0.0790

-0.0937 10.1084 0.1234 0.1385[0.16 9 3.

0.2000 0.2301 4.40 0.0108 0.0225 0.0349 10.0479 0.0614 0.0752 0.0893 10.1034 0.1177 0.1322 0.617 0.1912 0.2201

Calc Number: GEO.HIBIP.03.02 Rev Number: 0 Sheet Number: 30 of 349 Date: 08/27/03 4.50 0.0103 0.0214 0.0332 0.0456 0.0585 0.0716 l0.0850 0o.0985 l0.1122 0.1261 10.1545 l0.

1828 0.210 4.60 0.0098 0.0203 0.0315 0.0434 0.0556 0.0682 4_0.0809 1 0.0938 0.1070 0.1203 0.1475 1 0.1747 0.201 4.70 0.0093 0.0193 0.0300 0.0412 0.052s 0.0648 1 0.0770 0.0993 0.1019 0.1147 0.1409 0.1670 0.1929 4.80 0.0088 0.0184 0.0285 0.0391 0.0502 0.0616 0.0732 0.0830 0.0971 0.1094 0.1345 1 0.1597 0.1847 4.90 0.0084 0.0175 0.0270 0.037t 0.0476 0.0585 0.0696 0.0808 0.0924 _ 0.1043 0.1284 0.1526 0.1767 5.00 0.0080 0.0166 0.0256 0.0352 0.0452 0.0555 0.0661 0.0768 0.080 0.0994 0.1226 0.1458 0.1691 5.10

- 0.0076_ 0.0157-O.N43

'0m334 0.0429 ~0.0527 0.0627 0.0730 0.0837 _0:0947-0.1170 0.1394- >b618 5.20 0.0072 0.0149 0.0230 0.0316 0.0406 0.0499 0.0595 0.0694 0.0797 0.0902 0.1116 0.1331 0.1548 5.40 0.0065 0.0134 0.0206 0.0284 0.0365 0.0449 0.0536 0.0626 10.0721 0.0818 0.1016 0.1215 0.1416 5.60 0.0058 0.0120 0.0185 0.0254 0.0327 0.0404 0.0483 0.0565 0.0652 0.0742 0.0924 0.1107 0.1293 5.80 0.0052 0.0107 0.0165 0.0228 0.0294 0.0363 0.0435 0.0510 0.0589 0.0672 0.0840 0.1008 0.1180 6.00 0.0050 0.0101 0.0151 0.0204 0.0264 0.0326 0.0392 0.0460 0.0533 0.0609 0.0763 0.0917 0.1076 6.20 0.0051 0.0100 0.0149 0.0198 0.0248 0.0299 0.0353 0.0416 0.0482 0.0552 0.0693 0.0834 0.0980 6.40 0.0048 0.0096 0.0143 0,0191 0.0240 0.0290 0.0341 0.0394 0.0448 0.0505 0.0629 0.0759 0.0892 6.60 0.0045 0.0089 0.0134 0.0180 0.0227 0.0274 0.0323 0.0372 0.0422 0.0473 0.0573 0.0690 0.0812 6.80 0.0041 0.0083 0.0125 0.0169 0.0213 0.0258 0.0304 0.0351 0.0399 0.0447 0.0542 0.0638 0.0743 7.00 0.0038 0.0077 0.0116 0.0156 0.0198 0.0240 0.0283 0.0327 0.0372 0.0417 0.0507 0.0597 0.0695 7.20 0.0036 0.0071 0.0106 0.0143 0.0182 0.0221 0.0261 0.0302 0.0343 0.0385 0.0468 0.0552 0.0643 7.40 -0:0034 0.0068

-Odfioo 0.0133 0.0166 0.0202 0.0239 - 0.0216' 0.0314 0.0352 ' 0.0428 0.0505" 0oo589 7.60 0.0033 0.0065 0.0096 0.0127 0.0158 0.0189 0.0220 0.0252 0.0285 o0.0320 0.0389 0.0458 0.0535 7.80 0.0032 0.0062 0.0092 0.0122 0.0151 0.0181 0.0211 0.0242 -0.0274 0.0306 0.0371 0.0434 0.0497 8.00 0.0030 0.0060 0.0088 0.0117 0.0145 0.0173 0.0202 0.0232 -0.0263 0.0294 0.0357 0.0418 0.0480 8.50 0.0027 0.0054 0.0080 0.0105 0.0131 0.0156 0.0183 0.0210 0.0238 0.0267 0.0324 0.0380 0.0437 9.00 0.0025 0.0049 0.0072 0.0095 0.0118 0.0141 0.0166 0.0190 0.0216 0.0242 0.0294 0.03 0.03 9.50 0.0022 0.0044 0.0063 0.086, 0.010

0. 012 0.0150 0.0173 0.0196 0.0220 0.0268 0.0315 0.0362 10.00 0.0020 0.0040 0.0059 0.007 o.0o9o 0.0117 0.0137 0.0158 - 0.0179 0.0200 0.0244 0.0287 0.0330 I

Calc Number: GEO.L-HB IP. O.02 Rev Number: 0 Sheet Number: 31 of 3 49 Date: 08/27/03 Table 6-6a. Soil Spectra for M=7.8, Set 1, Median Soil Profile Per~

(-se)

O.1I j 0.2g 0.3p 0.4 4

0.5 1

0.6p, 0.7gz 0.8z 0.92&

L

1.

1.2z 1.,

1.6!-z 0.01 0.1897 ]0.3384 0.4477 0.5242

0. 5849 10.6751 0.7490 0.8004 0.8338 10.8554 -0.8899 0.8799 j0.8721 0.03 0.1947 J0.3445 0.4541

-0.5298 10.5899 10.6789 0.7532 0.8048 0.8384 0.8598 I0.8939 0.8831 0.8750 0.04 0.2087 0.3577 1 0.4644 0.5368 0.5957 I 0.6822 1 0.7570 0.8088 I 0.8425 0.8637 1 0.8975 f 0.8862 O.8776 0.05 0.2 107 0.3670 1 0.4770 1 0.5492 0.6055 1 0.6855 'I 0(.7610 0.g135 1 '6:8476 0U 86388 1I 0.902FV 0--.8902 0.06 0.2086 0.3609 0.4742 0.5490 0.6095 10.6925 10.7672 10.8194 0.8534 0.8746 10.9079 0.8953 0.85 0.07 0.2386 0.3954 0.5068 0.5767 0.6318 0.7009 0.7748 0.8263 0.8600 0.8811 0.9142 0.9011 t 0.Q90 0.08 0.2963 0.4712 0.5828 0.6392 0.6848 0.7267 0.7833 0.8345 0.8680 0.8888 0.9217 0.9079 0.96 0.09 0.3000 0.4636 0.5340 0.6176 0.6937 0.7724 0.8368 0.8785 0.9035 0.91'78 0.9392 0.9180 0.9039 0.10 0.3067 0.4981 0.60'21 0.6941 0.7548 0.8236 0.8846 0.9261 0.9512 0.9610 0.9777 0.9483 0.9266 0.11 0.3579 0.5638 0.6970 0.7609 0.8109 0.8467 0.8742 0.8902 0.8985 0.9079 0.9525 0.9404 0.9270 0.12 023261 0.5963 0.7491 0.8197 0.8678 0.9012 0.91251 0.9343 0.9375 0.9445 0.9789 0.9595 0.9431 0.13 0.3758 0.6562 0.7778 0.8052 10.8003 0.8396 0.8607 0.8753 0.9153 0.9414 0.9783 0.9600 0.9461 0.14 0.4134 0.6518 0.7578 0.8241 0.8669 0.8890 0.9158 0.9405 0.9560 0.9663 0.9873 0.9598 0.9525 0.15 0.3892 0.7021 0.8919 0.9904 1.0151 1.0285 1.0438 1.0628 1.0689 1.0679 1.0592 1.0194 0.98t46 0.16 0.4291 0.7241 0.9525... 136-.1.0495 1.1230 1.1812 1.2148

-1.2258 1.2208 1.2079 1.1539 1.0997 0.17 0.5173 0.8415 0.9790

'1.089'5 1.1I193 i.1j447

-1.1879 1.2281

'1.2461 1.2452 1.1316- -i.2003

1. I50T--

0.18 0.4384 10.7372 0.9118 1.0260 1.1.142 1.1604 1.1890 1.2190 11.2407 1.2427 1.2223 1.1686.

1.0776 0.19 0.4549 0.7147 0.9395 1.1411 1.243-7 11.2733 1.2545 1.2230 1.2066 1.2017 1.2079 1.1549 1.1154 0.20 0.5180 0.7301 0.9886 1.2291 1.3642 1.4234 1.4195 1.4139 1.4650 1.4915 1.4730' 1.3737 1.3149 0.21 0.5846 0.8381 1.0167

. 1.1917 1.3367 1.4611 1.5460 1.5982 1.6309 1.6350 11.6153 1.4906 1.4065 0.22 0.5447 0.8484 1.0999 1.2901 1.4-438 1.5754 1.6672 1.7274 1.7641 1.7773 1.7661 1.6374 1.5015 0.23 0.5104 0.8749 1.0919 1.2750 1.4132 1.5322 1.6234 1.6851 1.7326 1.7544 1.7565 1.6436 1.5 120 0.24 0.5405 L0040 1.2419 1.3847 1.4524 1.5430 1.6390 11.7247 1.8158 1.8593 1.8607 1.7646 1.6896 0.25 0.5590 1.0567 1.3771 1.4996 1.5828 1.6732 1.7458 1t.8022 1.8363 1.8682 1.8827 1.8080 1.7414 0.26 0.6050 1.1477 1.5129 1.6231 1.5828 1.6921 1.7806 1.8436 1.8851 1.9087 1.9266 1.8148 1.7130 0.27 0.5952 1.1347 1.5158 1.6572 1.6215 1.6930 1.7864 1.8567 1.8979 1.9236 1.9565 1.8565 1.7565 0.28 0.5630 1.0811 1.4663 1.6368 1.6313 1.7310 1.8303 1.8999 1.9462 1.9759 2.0199 1.9297 1.8303 0.29 0.5094 1.0089 1.3585 1.5801 1.7790 1.8970 1.9208 1.9435 1.9942 2.0294 2.0917 2.0095 1.9096 0.30 0.4846 1.0464 1.3985 1.5969 1.8026.

2.0023 2.1325 2.1931 2.2112 2.2173 2.2522 2.1677 2.0903 0.31 0.4335 0.9053 1.3053 1.5914 1.8686 2.08-76 2.2241 2.2980 2.3305 2.3471 2.3986 2.3241 2.2523 0.32 0.4260 0.8432 1.2465 1.5409 1.7848 1.9819 2.1153 12.1926 2.2358 2.2640 2.3392 2.2951 J2.2448 0.33 0.412.3 0.8250 1.1830 1.4386 1.6065 1.7567 1.8848 1.9812 2.0541 2.1079 2.2149 2.1770 2.0972 0.34 0.3945 0.7913 1.1367 1.3821 11.5443 1.6947 1.8253 1.9285 2.0059 2.0656 2.1912 2.1718 2.0941 0.35 0.3793 0.7596 1.0911 1.3276 1.4886 1.6942 1.8551 1.9734 2.0764 2.1598 2.2741 2.2242 2.1542 0.36 0.3738 0.7474 1.0756 1.3152 1.4912 1.6990 1.8651 1.9917 2.1002 2.1898 2.3106 2.2936 2.2195 0.37 0.3712 0.7440 1.0806 1.3367 1.5348 1.7328 1.9091 2.0461 2.1503 2.2329 2.4024 2.4072 2.3265 0.38 0.3599 0.7255 1.0616 1.3274 1.5373 1.7436 1.9225 I2.0601 2.2542 2.4027 2.5772 2.5630 2.4736 0.39 0.3658 0.7021 1.0350 1.3034 1.5207 1.7322 1.9267 2.1599 2.3979 2.5668 2.7660 2.8039 2.8165 0.40 0.3631 0.6738 1.0029 1.2792 1.5084 11.7326 1.9440

'2.2060 2.4326 2.6265 2.9744 3.1136 3.12Q77 0.41 0.3647 0.6457 0.9341 1.2101 1.4459 1.6989 2.0167

.2.3025 2.5493 2.7600 3.1322 3.2865 3.3116 0.42 0-3787 0.6459 0.8621 1.1023 1.3301 1.6152 1.9377 2.2264 2.4796 2.6961 3.0791 3.2483 3.2905 0.43 0.3864 0.6491 0.8793 1.013,5 1.2221 1.4611 1.7710 2.0537 2.3019 2.5161 2.9000 3.0918 3.1509

0. 4 4 0.3 8 1 7 0.6 5 7 8 0.8 9 6 8 1.0 4 1 8 1.1 6 4 1 1.3 5 1 4 1.5 9 7 6 1.8 7 0 7 2.1 1 4 8 2.3 2 6 8 2.7 1 5 8 2.9 3 0 9 3.0 1 1290

.8 6 8

.0 4 8 1. 9 7 6 1.8 0 7

.1 1 8 2. 2 6 8 1,7 1 8 2 9 3 0 0.45 0.3756 0.6768 0.9258 1.0811 1.1582 1.3251 1.4808 1.6944 1.9360 2.1486 12.5460 2.7859 2.8879 0.46 0.3740 0.6979 0.9562 1.1222 1.2071 1.3149 1.4720 1.5910 1.7445 1.9580 2.3595 2.6214 2.7441 0.47 0.3815 0.7134 0.9775 1.1536 1.2473 1.3413 1.4631 1.5874 1.6818 1.7572 2.1368 2.4146 2.5550 0.48 023808 0.7121 0.9761 1.1601 1.2650 1.3625 1.4501 1.5654 1.6656 1.7464 2.0160 2.2622 2.3689 0.49 0.3647 0.6817 0.9385 1.1276 1.2423 1.3436 1.4279 1.5021 1.6059 1.6895 1.9494 2.1892 2.2898 0.50 0.3345 0.6270 0.8726 1.0660 1.1886 1.2900 1.3692 1.4283 1.5071 1.5885 1.8290 2.0482 2.1396 0.51 0.3035 0.5750 0.8156 1.0156 1.1432 1.2418 1.3145 1.3637 1.4201 1.4923 1.7074 1.9043 I 19815 0.52 0.2848 0.5500 0.7969 1.0054 1.1353 1.2309 1.2974 1.3381 1.3902 1.4537 1.6374 1.8170 1.8857 0.53 0.2781 0.5484 0.8061 1.0223 1.1539 1.2485 1.3114 1T3457 1.4108 1.4697 1.6127 1.7853 1.8484i 0.54 0.2752 0.5523 0.8182 1.0415 1.1762 1.2702 1.3307 1.3722 1.4485 1.5062 1.6404 1.7681 1.8277 0.5 0.2727 0.5550 0.8295 1.0604 1.1990 1.2926 1.3504 1.4189 1.4939 1.5514 1.6896 1.7530 1.8090 0.56 0.'2717 0.5612 0.8464 1.0875 1.2281 1.3208 1.3810 1.4811 1.5559 1.6138 1.7594 1.8209 1.7967 0.57 0.2707 0.5670 0.8629 1.1122 1.2516 1.3408 1.4457 1.5458 1.6225 1.6827 1.8418 1.9166 1.8537 0.58 0.2720 0.5587 0.8572 1.1054 1.3059 1.4429 1.5195 1.5750 1.6550 1.7208 1.8960 1.9878 1.9334 0.60 0.2453 0.5003 0.8117 1.1328 1.3697 1.5337

.1.6476 1.7093 1.7300 1.7240 1.7925 1.9109 1.8806 0.62 0.2285 0.4794 0.7593 1.0611 I1.3721 1.6002 1.7500 1.8196' 1.8284 1.8086 1.8422 j~1.8433 1.7552 0.64 0.2208 I0.4672 0.7,453 1.79 134 1.6466 1.8212 1.9071 1.9257 1.9097 1.45 195 1.8342 0.66 0.2094 I0.4519 0.'7249 1.038 1.64 1.6-229 1.8039 1.937 [1.9143.

1.9321 2.34 201 1.9626

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 3 2 of 3 49

~~D ate: 08/27/03) 0.68 0.2121 0.4217 0.6307 0.9103 ]1.1960 1.4304 1.5954 1.7269 1.8196 11.3778 12.0043 2.0365 96 0.70 0.2142 0.4237 0.6368 0.9415 1.1010 1.3283 1.5219 1.6699 1.71762 1.R443 11.9804 2.01"3 1.43 0.72 0.2153 0.4277 0.6400 0.8297 j1.0822 1.319-7 1.5268 1.6889 1.9036 I1.8727 2.0080 2.0407 1.52 0.74 0.2147 0.4265 0.6385 0.8283 j1.0027 1.2219 1.4233 1.5787 1.6832 1.7401 1.8562 1.9011 1.9086 0.76 0.2125 0.4216 0.6313 0.8200 0.9939 1.1576 1.3053 1.4285 1.5317 1.17 1.7796 1.8929 1.9043 0.78 0.2088 0.4142 0.6202 0.8057 J0.9776 1.1396 1.2860 1.4087 41.5117 1.5944 1.7764 1.8977 1.8883

~'0.80-0.2046 0.4053

&06067 0.7883 OS9"7

-1.1168 1.26 13-1.3823 j1.484.7...1.5871 1.7734 1,9023

-.1.9090 0.82 0.2001 0.3960 0.5923 0.7696 0.9349 1.0916 1.2337 1.3534 1.4682 1.5741 1.7642 1.9003 1.9225 0.84 0.1955 0.3864 0.5776 0.7502 0.9119 1.0653 1.2049 1.3230 1.4485 1.5572 1.7505 1.8933 1.9301 0.86 0.1967 0.3767 0.5626 0.7305 0.8881 1.0381 1.1750 1.2948 1.4258 1.5366 1.7323 1.8810 1.9316 0.88 0.1986 0.3695 0.5475 0.7104 0.8639 1.0102 1.1442 1.2692 J1.4003 1.5123 1.7095 1.8635 1.9267 0.90 0.2003 0.3719 0.5325 0.6904-0.8396 0.9822 1.1131 1.2424 1.3727 1.4852 1.6828 I1.8411 11.9159 0.92 0.2016 0.3744 0.5314 0.6713 0.8162 10.9550 1.0827 1.2156 1.3443 1.4568 1.6539 1.8151 11.9005 0.94 0.023 0.3762 0.5326 0.6569 0.7945 0.9295 1.0576 1.1898 1.3164 1.4281 1.6240 1.7880 1.8823 0.96 0.2039 0.3774 10.5336 0.6549 0.7750 0.9064 1.0376 1.1656 1.2895 1.3998 1.5942 1.7600 1.8627 0.98 0.2079 0.3848 10.5414 0.6533 0.7680 0.8916 1.0190 1.1426 1.2634 1.3722 1.5644 1.7320 1.8421 1.00 0.2106 0.3907 0.5506 0.6627 0.7615 0.8794 1.0011 1.1200 1.2376 1.3444 1.5344 1.7030 1.8197 1.05 0.2128 0.3950 0.5582 0.6753

-0.7631 0.8536 0.9544 1.0603 1.1677 1.2678 1.4492 1.6174 1.'7472

'tTr~o 0.223 5 0.4130 0:5756 0.6831 0.7662 0.8457 0.9205-089 038

'113

.3407 152 169

1LI, 0.2215 0.4130 0.5778 0.6892 0.7764 0.8578 0.9315 0.9977 1.0637 1.1252 1.2447 1.3659 11.5077 1.20 0.2223 0.4205 0.5924 0.7080 0.7983 0.8835 0.9597 1.0240 1.0827 1.1335 1.2309 1.3299 1.4400 1.25 0.2053 0.3924 0.5557 0.6652

-0.7666 0.8682 0.9548 1.0260 1.0890 1.1449 1.2533 1.3482 1.4406 1.30 0.1833 0.3714 0.5505 0.7004 0.8288 0.9451 1.0474 1.1344 1.2127 1.2827 1.4209 1.5480 1.6668 1.35 0.1713 0.3601 10.5496 0.7222 0.8721 1.0018 1.1157 1.2106 1.2941 11.3653 11.4862 1.5781 1.6566 1.40 0.1728 0.3653 10.5617 0.7420 0.9002 1.0391 1.1531 1.2366 1.2967 1.3317 11.4'21 8 1.5275 1.6161 1.45 0.1605 0.3402 0.5281 0.70'73 0.8699 1.0149 1.1381 1.2343 1.3082 1.3561 11.4313 1.4857 1.5352 1.50 0.1534 0.3238 0.5046 0.6858 0.8552.

1.0067 1.1365 1.2397 1.3204 1.3746 1.4650 1.5303 1.5645 1.55 0.1496 0.3171 0.4957 0.6791 0.8530 1.0091 1.1433 1.2509 1.3358 1.3942 1.5012 1.5748 1.6145 1.60 0.1445 0.3074 0.4819 0.6622 0.8354 0.9928 1.1304 1.2414 1.3278 1.3902 1.5135 1.5943 1.6397 1.65 j0.1350 0.2879 0.4530 0.6257 I0.7987 0.9752 1.1283 1.2496 1.3407 1.3985 1.4904 1.5773 1.6283 1.70 0.1231 0.2632 0.4158 0.5783 0.7610 0.9368 1.0923 1.2189 11.3165 1.3807 1.4472 1.5390 1.5948 1.75 0.1125 0.2390 0.3788 0.5310 0.7054 0.8746 1.0266 1.1524 1.2511 1.3177 1.4055 1.5008 1.5603 1.80 0.1056 0.2243 0.3530 0.4915 j 0.6453 0.7994 0.9434 1.0653 1.17-24 1.2626 11.3876 1.4742 1.5360 1.85 0.1000 0.2126 0.3353 0.4693 0.6125 0.7614 0.9021 1.0291 1.1416 1.2343 1.3658 1.4554 1.5460 1.90 0.0949 0.2022 0.3196 0.4496 0.5862 0.7225 0.8606

-0.9866 1.0996 1.1943 1.3310-1.4318 1.5639 1.95 0.0891 0.1907 0.3023 0.4271 0.5590 0.6900 0.8165 0.9347 1.0442 1.1399 1.2900 1.4340 1.5700 2.00 0.0840 0.1771 0O.2809 0.3985 0.5235 0.6480 0.7689 0.8824 0.9880 1.0813 1.2599 1.4206 1.5564 2.05 0.0817 0.1721 0.2696 0.3774 0.4901 0.6037 0.7174 0.8295 10.9396 1.0439 1.2300 1.3886 1.5232 2.10 0.0782 0.1649 0.2583 0.3618 0.4705 0.5800 10.6897 10.7979 10.9045 1.0059 1.1874 1.3427 1.4757 2.15 0.0739 0.1563 0.2450 0.3437 0.4479 0.5529 0.6579 0.7618 0.8644 0.9624 11.1382 1.2896 1.4208 2.20 0.0692 0.1470 0.2311 0.3250 0.4246 0.5250 0.6254 0.7249 0.8232 0.9174 11.0873 11.2351 1.3649 2.25 0.0647 0.1379 0.2176 0.3068 0.4020 0.4978 0.5938 0.6890 0.7833 0.8740 1.0386 1.1834 1.3117 2.30 0.0603 0.1293 0.2047 0.2896 0.3805 0.4721 0.5639 0.6552 0.7458 0.8335 0.9937 1.1359 1.2625 2.35 0.0563 0O.1212 0.1925 0.2733 0.3601 0.4478 0.5359 0.6237 0.7112 0.7964 0.9526 1.0921 1.2167 2.40 0.0525 0.1135 0.1810 0.2578 0.3407 0.4247 0.5094 0.5942 0.6791 0.7619 0.9141 1.0507 1.1729 2.50 0.0497 0.1031 0.1594 0.2281 0.3037 0.3812 0.4599 10.5393 0.6189 0.6967 0.8401 0.9695 1.0858 2.60 0.0470 0.0975 0.1508 0.2080 0.2691 0.3407 0.4136 0.4871 0.5606 0.6325 0.7656 0.8867 0.9961 2.70 0.0444 0.0920 0.1423 0.1965 0.2523 0.3076 0.3698 0.4368 0.539 10.5696 0.6920 0.8044 0.9073 2.80 0.0419 0.0869 0.1345 0.1857 0.2388 0.2914 0.3432 0.3943 0.4507 0.5106 0.6229 0.7276 0.8258 2.90 0.0397 0.08'24

0. 1276 0.1763 0.2269 0.2771 0.3268 0.3756 0.4241 0.4716 0.5625 0.6591 0.7559 3.00 0.0379 0.0786 0.1218 0.1683 0.2168 0.2651 0.3128 0.3599 0.4067 0.4526 0.5407 0.6247 0.-7053 3.10 0.0362 0.0753 0.1166 0.1613 0.2081 0.2547 0.3010 0.3467 0.3920 0.4367 0.5229 0.6054 0.6852 3.20 0.0347 0.0722 0.1119 0.1550 0.2001 0.2453 0.2903 10.3348 0.3790 0.4227 0.5072 0.5883 0.7038 3.30 0.0332 0.0692 0.1073 0.1487 0.1923 0.2361 0.2798 0.3231 10.3664I 0.4091 10.4922 0.5729 0.6607 3.40 0.031 6 0.0660 0.1024 0.1421 0.1841 0.2265 0.2688 0.3109 0.3530 0.3948 0.4762 0.5559 0.6342 3.50 0.0298 0.0625 0.0972 0.13.50 0.1752 0.2160 0.2568 0.2976 0.3384 0.3790 0.4585 0.5367 0.6142 3.60 0.0280 0.0587 0.0915 0.1273 0.1656 0.2045 0.2436 0.2828 0.3221I 0.3614 0.4385 0.5150 0.5915 3.70 0.0260 0.0547 0.0853 0.1190 0.1551 0.1920 0.2292 0.2665 0.3042 0.3419 0.4162 0.4908 0.5663 3.80 0.0239 0.0504 0.0789 0.1102 0.1440 0.1786 0.2137 0.2491 0.2848 0.3208 0.3921 0.4647 0.5399 3.90 0.0227 0.0470 0.0727 0.1011 0.1325 0.1647 0.1975 0.2307 0.2645 0.2986 0.3669 0.4385 0.5123 4.00 0.0216 0.0446 0.0692 0.0954 0.1221 0.1506 0.1810 0.2120 0.2436 0.2759 0.3426 0.4122 0.4829 4.10 0.0205 0.0419 10.0646 0.0896 0.1155 0.1411 0.1661 0.1933 0.2229 0.2545 0.3190 0.3848 0.4516 4.20 0.0190 0.0390 10.0600 0.0833 0.1078 0.1323 0.1563 0.1794 0.2043 0.34

.2949 0.3566 0.4191 4.30 0.0173 0.0356 0.0550 0.0765 0.0993 0.1222 0.1449 0.1669 0.1883 0.19 0.2709 0.3282 0.3863 4.40 0.016 0.0342 10.0517 0.0697 0.0903 0.1115 0.1327 0.1535 0.1739 0.97

-I47 0(.-3002 0.3538

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 33 of 349 Date: 08/27/03 4.50 0.0172 1 0.0347 1 0.0526 1 0.0710 1 0.0899 1 0.1091 1 0.1289 1 0.1494 7 0.1705 1 0.1923 1 0.2371 0.2X4X I 0.335X 4 60 0.0166 1 00336 1 00510 1 0.0690 1 0.0574 1 0.1061 1 01252 1 0.1450 1 0 1654 1 0.-165 1 0.2300 0.2758 1 0.3247 4.70 0.0154 0.0312 0.0473 0.0640 0.0812 0.0987 0.1165 0.1348 030

.1733 0.2137 0.2564 0.3015 4.80 0.0142 0.0286 0.0432 0.0578 0.0725 0.0881 0.1040 0.1203 0.1372 0.1546 0.1907 0.2288 0.2691 4.90 0.0141 0.0285 0.0431 0.0579 0.0729 0.0879 0.1032 0.1190 0.1354 0.1522 0.1864 0.2222 0.2601 5.00 0.0136 0.0277 0.0420 0,0566 0.0714 0.0864 0.1016 0.1172 0.1333 0.1499 0.1838 0.2194 0.2569 5.10 0.01311.0.0266

-0.0405- -- 0549 0.0695 0.0841 0.0989 0.1141 0.1297 0.1458 0.1V87 - 0.2132 0-.2499"-

5.20 0.0125 0.0255 0.0388 0.0528 0.0670 0.0813 0.0957 0.1104 0.1256 0.1411 0.1729 0.2061 0.2412 5.40 0.0117 0.0235 0.0354 0.0478 0.0609 0.0740 0.0874 0.1010 0.1149 0.1293 0.15V7 0.1892 0.2212 5.60 0.0108 0.0218 0.0329 0.0443 0.0558 0.0672 0.0785 0.0898 0.10o9 0.1148 0.1413 0.1689 0.1976 5.80 0.0099 0.0201 0.0305 0.0411 0.0520 0.0629 0.0737 0.0844 0.0952 0.1062 0.1295 0.1546 0.1811 6.00 0.0091 0.0185 0.0281 0.0381 0.0484 0.0588 0.0691 0.0793 0.0895 0.0998 0.1215 0.1448 0.1696 6.20 0.0084 0.0172 0.0262 0.0356 0.0453 0.0552 0.0650 0.0748 0.0845 0.0942 0.1145 0.1362 0.1593 6.40 0.0079 0.0159 0.0243 0.0332 0.0423 0.0516 0.0610 0.0703 0.079.5 0.0887 0.1078 0.1281 0.1497 6.60 0.0082 0.0166 0.0250 0.0336 0.0424 0.0514 0.0604 0.0695 0.0788 0.0883 0.1076 0.1277 0.1484 6.80 0.0082 0.0165 0.0249 0.0334 0.0422 0.0510 0.0600 0.0691 0.0783 0.0877 0.1069 0.1268 0.1474 7.00 0.0079 0.0159 0.0240 0.0322 0.0405 0.0489 0.0575 0.0662 0.0751 0.0840 0.1023 0.1214 0.1410 7.20 0.0074 0.0149 0.0224 0.0302 0.0382 0.0462 0.0542 0.0622 0.0702 0.0784 0.0950 0.1125 0.1307 7.40

-0.0072_ 0.0145 0.0218 0.0294-0.0371 0.0450 "xO.0529 0.0608-0 0688 0.0768 0.6930 0.1099

0. 1275 7.60 0.0069 0.0138 0.0208 0.0280 0.0353 0.0428 0.0504 0.0580 0.0657 0.0734 0.0890 0.1052 0.1219 7.80 0.0065 0.0130 0.0195 0.0262 0.0330 0.0399 0.0470 0.0542 0.0614 0.0687 0.0834 0.0985 0.1142 8.00 0.0060 0.0120 0.0180 0.0241 0.0303 0.0366 0.0431 0.0497 0.0564 0.0631 0.0767 0.0907 0.1051 8.50 0.0047 0.0095 0.0143 0.0192 0.0242 0.0293 0.0344 0.0394 0.0445 0.0495 0.0593 0.0690 0.0796 9.00 0.0039 0.0079 0.0120 0.0161 0.0204 0.0248 0.0292 0.0337 0.0381 0.0426 0.0514 0.0600 0.0687 9.50 0.0031 0.0063 0.0095 0.0128 0.0163 0.0198 0.0234 0.0271 0.0308 0.0346 0.0420 0.0494 0.0567 10.00 0.0025 0.0051 0.0076 0.0100 0.0127 10.0155 0.0186 0.0218 0.0251 0.0283 0.0345 0.0406 0.0468

Caic Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 34 of 349 Date: 08/27103 Table 6-6b. Soi Spectra for M=7.8, Set 2, Median Soil Profile Pser

0.

0.2t 0.3R 0.4"-

0. 5 0.62 J 0.7g 0.82 I0.

9 L.0P 1.2z 1.4" 1.62 0.01 0.1448 0.2638 0.3296 0.3810 0.4847 0.5918 0.6836 0.7617 0.8332 0.8943 0.9909 1.0559 11.0884 0.03 0.1474 0.2693 0.3356 0.3834

-0.4875 0.5946 0.6862 0.7643 0.8361 10.8971 0.9936 1.0585 1.090X 0.04 0.1501 0.2736 0.3405 0.3860 0.4895 0.5966 0.688k 0.7666 0.8387 0.8999 0.9961 1.0608 1.0930 00 0.697 0.2884 10.3551 0.3831 044 0611 0.6921 -

07704~ 0842~'-

0:D.9615 0.9994..03~105 0.06 0.2044 0.2936 10.3591 0.4167 0.5043 0.6082 0.6975 0.7753 0.8478 0.9087 1.0044 1.0682 11.0996 0.07 0.2287 0.3167 10.3922 0.4306 0.4930 0.6019 0.6952 0.7757 0.8498 0.9117 1.0079 1.0720 11.1037 0.08 0.2498 0.3625 0.4335 0.4678 0.5045 0.5996 0.6849 0.7631 0.8409 0.9060-1.0069 1.0737 11.1071 0.09 0.2963 0.4408 0.5334 0.5767 0.6017 0.6690 0.7482 0.8164 0.8812 0.9375 1.0289 1.0893 11.1179 0.10 0.2936 0.4674 0.5565 0.6154 10.6497 0.7057 0.7805 0.8468 0.9102 0.9654 11.0518 1.1080 11.1337 0.11 0.3147 0.4644 0.604-7 0.6332 0.683-7 0.7234 0.7874 0.8531 0.9182 0.9731 1.0600 1.1158 11.1419 0.12 0.3576 0.5178 0.6017 0.6783 0.7354 0.7783 0.8129 0.8390 0.9090 0.9660 1.0558 1.1128 1.1414 0.13 0.3853 0.6622 0.7914 0.7871 0.7902 0.8436 0.8833 0.9099 0.91016 0.9185 1.0177 1.0842 1.1223 0.14 0.4128 0.6889 10.8382 0.8691 0.8723 0.8771 0.8623 0.8845 0.9002 0.9231 0.9788 1.0545 1.1039 0.15 0.4282 0.7066 10.8783 0.9318 0.9435 0.9541 0.9483 0.9198 0.8732 0.9001 0.9801 1.0589 1.1068 0.6 0.4342 0.7-303

r.

.. 09191 1.0075 1.0474 1.0236 1.0254 1.0053 0.9380 0.9200 10.9771 1.0471..

1.0986 0.17 0.4681 0.7547 0.9713 1.0686 1L1596

-1.1646 1.1281 1.1065 1.0571 1.0601 11.0635 TO060V "1.1042 0.18 0.4412 0.7924 1.0427 1.1456 1.1646 1.2010 1.2286 1.24 1.2058 1.2043 11.1968 1.1901 1.1148 0.19 0.4364 0.7775 1.0246 1.1316 1.2259 1.3133 1.3758 1.4127 1.4071 I1.4097 1.4175 1.3982 1.3258 0.20 0.4536 0.7892 1.0584 1.2492 1.3847 1.4840 1.5582 1.6044 1.6023 1.6077 1.6159 1.5935 1.5074 0.21 0.4660 0.8049 1.0798 1.2763 1.4232 1.5356 1.6204 1.6752 1.6825 1.6957 1.7139 1.6972 1.6140 0.22 0.5201 0.8253 1.1038 1.3106 1.4664 1.5942 11.6882 1.7495 1.7678 1.7883 1.8169 1.8024 1.7190 0.23 0.5430 0.9575 1.1263 1.3428 1.5157 1.6536 1.7589 1.8313 1.8550 1.8845 1.9238 1.9172 1.8344 0.24 0.5193 0.9614 1.1362 1.3621 1.5478 1.6996 1.8141 1.8928 1.9288 1.9651 2.0187 2.0158 1.9355 0.25 0.4762 0.8958 1.1708 1.3740 1.5692

-1.7322 1.8555 1.9448-1.9907 2.0367 2.1022 2.1078 2.0304 0.26 0.4702 0.8430 1.1401 1.3772 1.5857 1.7569 1.8897 1.9869 2.0406 2.0956 2.1740 2.1878 2.1147 0.27 0.5095 0.8924 1.1746 1.3860 1.5967 1.7778 1.9172 2.0197 2.0867 2.1492 2.2410 2.2613 2.1936 0.28 0.5156 0.9266 1.2167 11.4282 1.6035 1.7894 1.9344 2.0472 2.1213 2.1933 2.2972 2.3275 2.2649 0.29 0.4903 0.8871 1.2160 1.4608 1.5939 1.7833 1.9347 2.0521 2.1378 2.2177 2.3380 2.3752

-2.3205 0.30 0.4421 0.8440 1.1640 1.3994 1.6187 1.7521 1.9073 2.0330 2.1306 12.2209 12.3541 2.4026 2.3554 0.31 0.4284 0.7791 1.0549 1.3666 1.6123 1.7716 1.8682 2.0003 2.1107 2.2094 12.3568 2.4126 2.3745 0.32 0.4149 0.7537 1.0190 1.3146 1.5806 1.7656 11.8625 1.9773 2.0977 2.2038 12.3623 12.4262 12.3943 0.33 0.4053 0.7348 0.9929 1.2611 1.5726 1.8248 11.9318 1.9744 2.1041 2.2171 2.3834 12.4544 2.4282 0.34 0.3997 0.7237 0.9784 1.2716 1.6817 1.9656 2.0914 2.1186 2.1263 2.2460 2.4203 12.4951 12.4736 0.35 0.3962 0.7169 0.9701 1.2233 1.6286 1.9216 2.0546 2.0865 2.1533 2.2791 2.4608 2.5389 2.5221 0.36 0.3927 0.7102 0.9619 1.1907 1.4324 1.7052 1.8756 2.0249 12.1760 2.3061 2.4951 2.5783 12.5661 0.37 0.3879 0.7016 0.9502 1.1785 1.4188 1.6523 1.9382 2.1139 2.1882 2.3223 12.5204 2.6101 12.6038 0.38 0.3818 0.6908 0.9349 1.1610 1.4031 1.6396 1.8505 12.0258 2.1897 2.3319 12.5376

'2.6309 12.6307 0.39 0.3752 0.6769 0.9159 1.1387 1.3802 1.6186 1.8290 2.0145 2.1856 2.3320 12.5448 2.6462 12.6527 0.40 0.3670 0.6610 0.8920 1.1102 1.3498 1.5903 1.8034 1.9946

2. 1724 2.3239 2.5456 12.6502 12.6637 0.41 0.3878 0.6419 0.8648 1.0763 1.3137 1.5546 1.7710

-1.9651 2.1488 2.3430 2.5830 12.6435 2.6631 0.42 0.4082 0.6398 0.8311 1.0336-1.2663 1.5060 1.7244 L9230 2.1171 2.3449 2.6125 12.6888 12.6707 0.43 0.4128 0.6541 10.8012 0.9826 1.2084 1.4453 1.6634 1.8632 2.0655 2.2979 2.5818 12.6669 12.6555 0.44 0.4009 0.6393 0.7872 0.9203 I.I359 1.3669 1.5823

-1.7832 2.0016 2.2641 2.6961 12.8843 12.8903 0.45 0.4436 0.6947 0.8204 0.9298 1.0488 1.2717 1.4947 1.7535 2.0757 2.3753 12.8721 13.0939 13.1176 0.46 0.4654 0.7453 0.8781 0.9696 1.0935 1.2696 1.4596 1.6687 2.0026 2.3175 12.8441 13.0870 3.1298 0.47 0.4433 0.7274 0.8792 0.9747 1.0721 1.2275 1.3975 1.5884 1.8287 2.0846 2.6883 2.9900 3.0766 0.48 0.4130 0.7193 0.9000 1.0506 1.1817 1.2924 1.4269 1.5772 1.7864 2.0134 2.5121 2.8146 2.9106 0.49 0.4141 0.7217 0.9180 1.0835 1.2307 1.3606 1.4619 1.5635 1.7776 2.0122 2.4998 2.8159 2.9995 0.50 0.3734 0.6755 10.9053 1.0784 1.2338 1.3749 1.4871 1.5955 1.7801 1.9875 2.4676 2.8168 2.9892 0.51 0.3330 0.6583 10.9129 1.0792 1.2154 1.3622 1.4804 1.5922 1.7735 1.9755 2.4373 2.7701 2.9340 0.52 0.3224 0.65899 0.9251 1.1045 1.2354 1.3458 1.4681 1.5816 1.7595 1.9572

-2.4030 2.7256 2.8834 0.53 0.3216 0.6599 10.9362 1.1266 1.2663 1.3829 1.4697 1.5732 1.7490 1.9437 2.3816 2.6981 2.8551 0.54 0.3197 0.6592 10.9424 1.1397 1.2855 1.4084 1.5033 11.5803 1.7334 1.9253 2.3572 2.6713 12.8299 0.55 0.3131 0.6490 0.9333 1.1323 1.2809 1.4080 1.5104 11.5952 1.7370 1.9011 12.3076 2.6157 12.7750 0.56 0.2993 0.6231 0.9001 1.0950 1.2423 1.3718 1.4806 11.5730 1.7169

-1.8790 12.2757 2.5452 12.6668 0.57 0.2781 0.5818 0.8435 1.0335 1.1861 1.3025 1.4153 11.5144 1.6581 1.8155 2.1939 2.4512 12.5224 0.58 0.2561 0.5310 0.7716 0.9805 1.1785 1.3084 1.3833 1.4582 1.5968 1.7468 2.0804 2.3292 2.4891 0.60 0.2538 0.5223 0.8168 1.0864 1.2963 1.4204 1.5225 1.6045 1.7166 1.8340 2.1719 2.4455 2.6300 0.62 0.2389 0.4875 0.7574 1.0028 1.2347 1.4507 1.5951 1.6885 1.8156 1.9463 2.2453 2.4467 2.5062 0.64 0.2083 0.4471 10.6987 0.9566 1.2126 1.4303 1.5809 1.6786 1.8088 1.9414 2.2389 2.4318 2.4852 0.66 0.2088 0.4523 10.7013 0.9396 1.1952 1.4177 1.6107 2.7574 1.9222 2.0810 2.4222 2.6237 2.6227

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 35 of 3 49

~~ ~~~~Date:

08/27/03) 0.68 0.2179 j0.4383 0.6830 0.9331 1.1?50 1.4234 1.6189 1.7678 1.9328 2.0911 2.4245 2.6198 2.6219 0.70 0.2213 j0.4489 0.6657 0.8689 1.0920 1.3165 1.5010 1.6424 1.7960 1.9580 2.2?81 2.4766 2.5114 0.72 0.2119 10.4311 0.6414 0.8371 1.0330 1.2215 1.3897 1.537-7 1.7086 1.8722 2.1915 2.4306 2.4839 0.74 0.2141 0.4349 0.6495 0.8508 1.0524 1.2489 1.4288 1.5930 1.7817 1.9614 2.3078 2.5605 2.6170 0.76 0.2094 0.4255 0.6416 0.8464 1.0527 1.2536 1.4382 1.6062 1.7972 1.9790 2.3273 2.5998 2.6610 0.78 0.1998 0.4032 0.6109 0.8085 1.0067 1.1988 1.76 1.5351 1.7175 1.8929 2.2561 2.5308 2.6102 0.80:

0.1975 0.393

--0.5981t-A0.7966 -0.9953...*49 1.3691.- *..1,5355

.41.7-236 1.9052

. 2.2846 2.5717.

2.~66.

0.82 0.1996 0.3792 0.5664 0.7594 0.9547 1.1465 1.3266 1.4939 1.6804 1.8604 2.2427 2.5277 2.6183 0.84 0.2073 0.3942 0.5720 0.7302 0.8763 1.0245 1.1899 1.3433 1.5095 1.6874 2.0521 2.3437 2.5547 0.86 0.2122 0.4047 0.5893 0.7571 0.9137 1.0641 1.2169 1.3-798 1.5689 1.7595 2.1415 2.4469 2.6607 0.88 0.2039 0.3904 0.5702 0.7358 0.8915 1.0392 1.1863 1.3410 1.5198 1.7002 2.0647 2.3534 2.5471 0.90 0.1921 0.3680 0.5374 0.6935 0.8398 0.9767 1.1107 1.2498 1.4101 1.5718 1.8996 2.1572 2.3298 0.92 0.1937 0.3697 0.5377 0.6918 0.8357 0.9693 1.0993 1.2331 1.3868 1.5424 11.8574 2.1073 2.2861 0.94 0.2024 0.3853 0.5591 0.7188 0.8693 1.0094 1.1453 1.2847 11.4437 1.6047 11.9318 2.1969 2.3975 0.96 0.2012 0.3831 0.5565 0.7171 0.8703 1.0136 1.1519 1.2930 1.4528 1.6141 1.9427 2.2123 2.4208 0.98 0.1933 0.3601 0.5239 0.6768 0.8237 0.9611 1.0930 1.2267 1.3770 1.5280 1.8362 2.0906 2.2873 1.00 0.1892 0.3483 0.4937 0.6378 0.7761 f0.9050 1.0278 1.1518 1.2901 1.4291 1.7118 1.9451 2.1252 1.05 10.2094 0.3792 0.5252 0.6432 0.7635 10.888 1.0072 1.1260 1.2573 1.3882 1.6527 1.8734 2.0547 1.10 0.2173-0.3978 0:i4~9 0.6578 0.7607..

0.856-5 0.9487 1-04491- '1. 1548 1.2669.

'.-14954 1.69&2

.. 1-.S988 1.15 0.2178 0.3979 10.5662 0.7062 0.8262 0.9304 1.0259 1.1214 1.2292 1.3371 1.5531 1.7428 1.9374 1.20 0.2067 0.4072 0.5950 0.7592 0.9079 1.0431 1.1638 1.2720 1.3801 1.4781 1.6447 1.7285 1.7768 1.25 0.2083 0.4061 0.5915 0.7618 0.9180 1.0617 1.1927 1.3131 1.4340 1.5438 1.7311 1.8299 1.816857 1.30 0.1916 0.3861 0.5705 0.7395 0.8919 1.0262 1.1493 1.2717 1.3951 1.5077 1.7007 1.8055 184 1.35 0.1833 0.3729 0.5601 0.7343 0.8935 1.0361 1.1598 1.2671 1.3730 1.4683 1.6357 1.7413 1.7776 1.40 0.1760 0.3610 0.5467 10.7232 0.8862 1.0333 1.1623 1.2748 1.3843 1.4827 1.6480 11.7214 1.7275 1.45 0.1681 0.3477 0.5-296 0.7050 0.8683 1.0167 1.1476 1.2626 1.3735 1.4727 1.6388 11.7117 1.7122 1.50 0.1583 0.3294 0.5040 0.6739 0.8335 0.9796 1.1095 1.2242 1.3343 1.4322 1.5946 1.6637 1.6574 1.55 0.1460 0.3054 0.4692 0.6300 0.7825 0.9314 1.0869 1.2273 1.3597 1.4769 1.6696 1.7594 1.7642 1.60 0.1330 0.2782 0.4334 0.5990 0.7677 0.9322 1.0862 1.2269 1.3603 1.4785 1.6727 1.7616 1.7633 1.65 0.1334 0.2787 0.4358 0.6030 0.7738 0.9411 1.0984 1.2425 1.3773 1.4962 1.6896 1.7755 1.7718 1.70 0.1252 0.2618 0.4103 0.5688 0.7306 0.8893 1.0389 1.1763 1.3027 1.4136 1.5942 1.7417 1.7956 1.75 0.1106 0.2312 0.3624 0.5031 0.6469 0.7887 0.9238 1.0495 1.1758 1.3008 1.5258 1.6780 1.7359 1.80 0.1029 0.2164 10.3400 0.4740 0.6176 0.7669 0.9173 1.0653 1.2078 1.3415 1.5828 1.7469 1.8059 1.85 0.1063 0.2243 0.3534 0.4967 0.6500 0.8098 0.9716 1.1314 1.2843 1.4264 1.6797 11.8454 1.8931 1.90 0.1005 0.2137 0.3387 0.4780 0.6276 0.7835 0.9414 1.0967 1.2443 1.3797 1.6170 11.7640 1.8404 1.95 0.0897 0.1918 0.3051 0.4319 0.5684 0.7112 0.8556 0.9973 1.1319 1.2545 1.4855 11.6755 1.7939 2.00 0.0820 0.1724 0.2723 0.3859 0.5104 0.6434 0.7822 0.9238 1.0022 1.1938 1.4536 1.6995 1.8834 2.05 0.0762 0.1618 0.2558 0.3630 0.4852 10.6184 0.7604 10.9082 1.0543 1.1962 1.4708 1.7121 1.8813 2.10 0.0758 0.1576 0.2456 0.3393 0.38 10.5576 0.6845 10.8163 0.9467 1.0727 1.3136 1.5153 1.6451 2.15 0.0741 0.1545 0.2414 0.3348 0.4328 10.5351 0.6420 0.7538 0.8668 0.9790 11.2027 1.4196 1.6195 2.20 0.0714 0.1493 0.2338 0.3255 0.4223 0.5235 0.6291 0.7391 0.8502 0.9603 11.1803 1.3944 1.5926 2.25 0.0679 0.1424 0.2235 0.3122 0.4065 0.5054 0.6085 0.7158 0.8238 0.9309 1.1450 1.3542 1.5485 2.30 0.0637 0.1341 0.2109 0.2955 0.3860 0.4813 0.5810 0.6844 0.7884 0.8915 1.0977 11.3000 1.5021 2.35 0.0589 0.1245 0.1963 0.2759 0.3615 0.4522 0.5471 0.6458 0.7449 0.8430 1.0396 1.2.332 1.4151 2.40 0.0556 0.1149 0.1801 0.2539 0.3336 0.4186 0.5080 0.6011 0.6944 0.7868 0.9725 1.1563 1.3411 2.50 0.0536 0.1099 0.1706 0.2373 0.3092 0.3860 0.4675 0.5532 0.6403 0.7276 0.9065 1.0931 1.2852 2.60 0.0496 0.1019 0.1577 0.2191 0.2855 0.3568 0.4330 0.5132 0.5946 0.6763 0.8437 1.0191 11.2018 2.70 0.0444 0.0918 0.1420 0.1968 0.2565 0.3210 0.3903 0.4637 0.5380 0.6128 0.7663 0.9285 1.1000 2.80 0.0390 0.0807 0.1248 0.1729 0.2253 0.282!

0.3437 0.4093 0.4759 0.5430 0.6812 0.8288 0.9872 2.90 0.0388 0.0795 0.1217 0.1649 0.2100 0.2604 0.3140 0.3707 0.4287 0.4874 0.6088 0.7376 0.8745 3.00 0.0349 0.0727 0.1125 0.1536 0.1968 0.2440 0.2942 0.3472 0.4012 0.4561 0.5696 0.6905 0.8201 3.10 0.0351 0.0723 0.1112 0.1522 0.1947 0.2387 0.2.839 0.3299 0.3758 0.4238 0.5294 0.6424 0.7647 3.20 0.0313 0.0649 0.1006 0.1387 0.1788 0.2205 0.2639 10.3086 0.3534 0.3979 0.4892 0.5948 0.7112 3.30 0.0298 0.0603 0.0913 0.1238 0.1578 0.1936 0.2320 10.2735 0.3164 0.3601 0.4510 10.5514 10.6653 3.40 0.0282 0.0572 0.0867 0.1194 0.1545 0.1912 0.2296 10.2693 0.3091 0.348j 0.4297 0.5171 0.6250 3.50 0.0264 0.0537 0.0816 0.1107 0.1437 0.1791 0.2163 0.2551 0.2941 0.3332 0.4135 0.4995 0.5937 3.60 0.0245 0.0500 0.0762 0.1035 0.1322 0.1621 0.1935 0.2265.

0.2607 0.295 0.3698 0.4529 0.5474 3.70 0.0226 0.0471 0.0733 0.1007 0.1288 0.1573 0.1864 0.2163 0.2464 0.2767 0.3442 0.4'215 0.5095 3.80 0.0229 0.0477 0.0744 0.102-7 0.1318 0.1614 0.1917 0.2228 0.2541 0.2856 0.3499 0.4173 0.4881 3.90 0.0235 0.0486 0.0755 0.1045 0.1346 0.1656 0.1974 0.2301 0.2630 0.2961 0.3638 0.4359 0.5130 4.00 0.0228 0.0470 0.0729 0.1010 0.1305 0.1611 0.1927

-0.2253 0.2581 0.2913 0.3597 0.4335 0.5136 4.10 0.0205 0.0422 0.0654 0.0905 0.1173 0.1453 0.1'743 0.2044 0.2349 0.2658 0.3300 0.4000 0.4772 4.20 0.0182 0.0369 0.0562 0.0767 0.0996 0.23 0190 0.175.1 0.2015 0.2284 0.2848 0.3470 0.4162 4.30 0.0185 0.0375 0.0571 0.0774 0.0985 0.102

.1429 0.664 0.1903 f0.2144 0.2643 0.3178 0.3759 4.40 10.0175 0.0355 0.0541 0.0733 0.0931 0.113 0.34 051 0.1796 I0.2025 0.2501 0O.3018 0.3591

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 36 of 349 Date: 08/27/03 4.50 0.0164 F 0.0332 1 0.0504 0.0682 I 0.0864 0.1050 1 0.1240 1 0.1431 10.1623 0.1 OI29 10.2260 10.2735 10.3269 4.60 0.0154 0.0314 0.0480 0.0652 0.0828 0.1008 0 0.1190 1 0.1374 0.1556 0.1741 0.2120

.2512 1 0.3010 4.70 0.0165 0.0337 0-0517 0.0704 0.0897 0.1095 j 0.1296 0.1501 0.1705 0.1907 0.2311 0.2714 0.3119 4.80 0.0166 0.0342 0.0526 0.0719 0.0920 0.1127 ; 0.1340 0.1556 0.1773 0.1989 10.2423 0.2866 1 0.3321 4.90 0.0158 0.0326 0.0502 0.0689 0.0886 0.1090 0.130!

0.1517 0.1734 0.1951 10.2390 0.2846 0.3324 5.00 0.0145 0.0298 0.0459 0.0631 0.0813 0.1004 0.1203 0.1408 0.1615 0.1822 0.2243 0.2688 J0.3162

.: :,5.10-

- 0.0132 0:0270 0.0414 0:0568 0.0732 0.0906

-O.1098 0.1278

.0.146 9-0.1661 0.2055-.. 2474 J0.2927 5.20 0.0122 0.0247 0.0378 0.0518 0.0667 0.0826 0.0994 0.1170 0.1346 0.1525 0.1891 0.2285 0.2713 5.40 0.0113 0.0225 0.0341 0.0464 0.0596 0.0738 0.0888 0.1047 0.1207 0.1370 0.1706 0.2072 0.2473 5.60 0.0114 0.0229 0.0342 0.0452 0.0560 0.0665 0.0768 0.0903 0.1044 0.1189 0.1491 0.1826 0.2203 5.80 0.0112 0.0228 0.0346 0.0464 0.0581 0.0697 0.0816 0.0939 0.1066 0.1195 0.1459 0.1734 0.2016 6.00 0.0111 0.0228 0.0348 0.0471 0.0593 0.0715 0.0839 0.0966 0.1098 0.1231 0.1507 0.1798 0.2102 6.20 0.0104 0.0211 0.0319 0.0428 0.0537 0.0645 0.0749 0.0850 0.0966 0.1086 0.1334 0.1601 0.1888 6.40 0.0101 0.0205 0.0312 0.0421 0.0531 0.0642 0.0751 0.0857 0.0962 0.1064 0.1263 0.1453 0.1648 6.60 0.0083 0.0171 0.0263 0.0357 0.0453 0.0551 0.0648 0.0744 0.0839 0.0932 0.1112 0.1300 0.1516 6.80 0.0080 0.0158 0.0234 0.0314 0.0399 0.0485 0.0570 0.0661 0.0751 0.0841 0.1019 0.1196 0.1398 7.00 0.0078 0.0155 0.0233 0.0313 0.0394 0.0476 0.0561 0.0647 0.0734 0.0823 0.1003 0.1189 0.1378 7.20 0.0075 0.0151 0.0229 0.0308 0.0388 0.0469 0.0551 0.0633 0.0715 0.0797 0.0961 0.1126 0.1294 7.40 0.0071 0.0143 0.0217 0.0193- -BU.0370 0.0449 -

00529 0.0610-o.090, 0.0771 0.0933 0.1098

0. 1268.

7.60 0.0068 0.0137 0.0209 0.0282 0.0355 0.0428 0.0501 0.0574 0.0647 0.0719 0.0861 0.0998 0.1128 7.80 0.0064 0.0128 0.0196 0.0265 0.0335 0.0405 0.0475 0.0546 0.0616 0.0686 0.0823 0.0957 0.1084 8.00 0.0059 0.0118 0.0180 0.0244 0.0309 0.0375 0.0441 0.0507 0.0573 0.0639 0.0769 0.0896 0.1018 8.50 0.0051 0.0100 0.0148 0.0196 0.0244 0.0293 0.0343 0.0394 0.0447 0.0500 0.0608 0.0717 0.0828 9.00 0.0049 0.0098 0.0148 0.0198 0.0248 0.0299 0.0350 0.0403 0.0458 0.0513 0.0626 0.0746 0.0873 9.50 0.0048 0.0097 0.0147 0.0198 0.0249 0.0302 0.0355 0.0409 0.0462 0.05 16 0.0624 0.0733 0.0845 10.00 0.0040 0.0080 0.0122 0.0166 0.0210 0.0255 0.0302 0.0348 0.0395 0.0442 0.0537 0.0634 0.0735

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 3 7 of 3)4 9 Date: 03/27/03)

Table 6-6c. Soi Spectra for M~.8, Se 3, Median Soil Profile______

Per (Sec)

0. I&

02g 0.3g O.4e 0.5it 0.6it 0.7g 0.8g 0.9 1.0z 1.2g 1.6,,

0.1 0.1621 0.2844 0.4026 0.4813 0.5331 0.5710 0.6123 0.6835 0.7918 0.8772 0.9571 0.9759 0.9600 0.03 0.1654 0.2881 0.4068 0.4857 0.5369 0.5743 0.6150 0.6849 0.79-27 0.8-785 0.9588 0.9777 0.9619 0.04 0.1669 0.2911 0.4105

-0.4896 0.5407.

0.5776 0.6174 0.6864 0.7934 0.8796 0.9602 0.9792 0.9634 0.05 0.1740 0.2955 0.4159 0.4950 0.545.821 0.6202 0.6894 0.7945

0. 89) 0 0.9620 0.9813-U.'9654 0.06 0.1795 0.3032 10.4240 0.5038 0.5539 0.5889 0.6260 0.6937 0.7959 0.8826 0.9644 0.9838 0.9678 0.07 0.1957 0.3082 0.4313 0.5122 0.5625 0.5963 0.6320 0.6976 0.7984 0.8850 0.9672 0.9866 0.9706 0.08 0.2283 0.3123 0.4377 0.521-7 0.5726 10.6039 0.6340 0.6980 0.7922 0.8828 0.9688 0.995 0.9738 0.09 0.2450 0.3470 0.4703 0.5457 -0.5911 10.6229 0.6596 0.7170 0.8102 0.8951 0.9773 0.9961 0.9795 0.10 0.3021 0.4707 0.5853 0.6489 0.6819 10.6999 0.7138 0.7660 0.8220 0.8904 0.9698 0.9893 0.9-743 0.11 0.3053 0.5058 0.5917 0.6144 0.6702 10.6990 0.7691 0.8157 0.8211 0.8878 0.9731 0.9944 0.9795 0.12 0.3356 0.4970 0'.6231 0.7062 0.7578 0.7730 0.8243 0.8722 0.8875 0.9175 0.9509 0.9740 0.9642 0.13 0.3439 0.5802 0.6890 0.6947 0.7249 0.7992 0.8707 0.9197 0.9539 0.9832 11.0061 1.0092 0.9906 0.14 0.4019 0.5816 0.7157 0.7479 0.8104 0.8787 0.9206 0.92-70 0.8916 0.9575 11.0174 1.0296 1.0133 0.15 0.4083 0.6393 0.7278 0.7933 0.8416 0.9104 0.9593 0.9736 0.9304 0.9332 0.9739 0.9936 0.9894 O.06..

rp0.4430 0.6813

.0.8615 0.9555 1.0220.

1.0372 1.0064 0.9776 1.0058

.1.0317..

1.0411 1.0369 1.0109 0.17 0.4492 0.7286 0.8694 0.9762 1.0507 1.0867 1.0780 1.10-70 1.1632

1. 1862 1.1739 1.15 24 1.1138 0.18 0.4193 0.6832 0.8594 0.9003 0.9839 11.0747 1.1688 1.2517 1.3114 1.3392 1.3130 1.,2767 1.2291 0.19 0.4204 0.6633 10.8549 0.9346 1.0516 1.1640 1.2614 1.3214 1.3 199 1.3268 1.3232 1.2943 1.2583 0.20 0.4286 0.6679 10.8487 1.0083 1.1053 1.1938 1.2927 1.3568 1.3600 11.3595 1.3355 1.3122 1.3116 0.21 0.5161 0.6959 0.8707 1.0032 1.1309 1.2470 1.3406 1.4068 11.4122 1.4184 1.4027 1.3811 123762 0.22 0.5738 0.7881 0.9247 1.0838 1.2222 1.3016 1.3452 1.4118 1.4294 1.4462 1.4395 1.4169 1.4100 0.23 0.6012 0.8361 0.9392 1.1038 1.2450 1.3636 1.4322 1.4440 1.4163 1.4676 1.4980 1.4938 1.4522 0.24 0.5006 0.9499 1.0820 1.1416 1.2838 1.4180 1.4949 1.5086 1.5131 1.5989 1.6266 1.6152 1.5681 0.25 0.5262 0.9455 1.2075 1.2926 1.3250 11.4630 1.5739 1.6055 1.5701 1.6331 11.6664 1.6499 1.6021 0.26 0.5549 0.9945 11.3065 1.4146 1.4527 11.5311 1.5614 1.5319 1.5164 1.6079 1.6423 1.6214

.i5757 0.27 0.5413 0.9509 1.2714 1.4225 1.5103 i1.6035 1.6571 1.6576 1.5783 1.5 122 1.4588 1.4412 1.4564 0.28 0.5821 1.0691 1.3955 1.6213 1.7799 1.8552 1.9539.

1.7878 1.6515 1.5861 1.5639 1.5090 1.4798 0.29 10.5442 1.0374 1.3859 1.6096 1.7672 1.8524 1.8689 1.8273 1.7165 1.6603 1.6322 1.5695 1.5309 0.30 0.4940 0.9779 1.3177 1.5308 1.7510 1.8981 1.9352 1.8440 1.6949 1.6468 1.6208 1.5688 1.5128 0.31 0.4322 0.9200 1.3018 1.5603 1.7917 1.9507 1.9950 1.9112 1.8282 1.7812 1.7301 1.6722 1.6265 0.32 0.3856 0.7997 1.1979 1.4946 1.7077 1.8489 1.9370 1.9348 1.8546 1.8125 11.7673 1.7142 1.6749 0.33 0.3764 0.7491 1.1301 1.41446 1.6229 1.8251 1.9402 1.9488 1.8355 1.8037 11.7317 1.6551 1.6601 0.34 0.3704 0.7372 1.0751 1.3823 1.6819 1.9077 2.0353 2.1298 2.0692 1.9996 1.9385 1.8938 1.8973 0.35 0.3614 0.7389 1.1071 1.4400 1.7639 2.0017 2.1316 2.1667 2.1286 2.1060 2.0902 2.0519 2.0584 0.36 0.3224 0.6562 1.0044 1.3200 1.5982 1.8209 2.0709 2.2113 2.1902 2.1771 2.1838 2.1516 2.1602 0.37 0.3189 0.5736 0.8656 1.1724 1.4891 1.7806 2.0416 2.1960 2.2405 2.2471 2.2938 2.2655 223008 0.38 0.3095 0.5927 0.8696 1.1228 1.4425 1.7658 2.0720 2.3151 2.3624 2.3916 12.4270 2.4226 12.4711 0.39 0.3170 0.5526 10.8485 1.1135 1.4288 11.7586 2.0780 2.3418 2.3812 2.3178 12.3749 2.3832 12.4406 0.40 0.3311 0.548-2 0.7582 1.0159 1.3147 11.6359 1.9540 2.2210 2.4175 2.4516 2.4517 2.4272 12.4769 0.41 0.3415 0.5712 0.7365 0.9598 1.2161 11.4953 1.7915 2.1232 2.3503 2.4596 2.5906 2.5998 12.6020 0.42 0.3395 0.5568 0.7261 0.9238 1.1398 11.4269 1.7212 2.0338 2.3979 2.6097 2.7713 2.7947 12.8095 0.43 0.3575 0.5534 0.7140 0.8952 1.1427 11.3935 1.6437 2.0026 2.4102 2.6529 2.8368 2.8710 2.8949 0.44 0.3460 0.5752 0.7405 0.8660 1.0773 1.3 199 1.568 1 1.833 1 2.2022 2.4472 2.6243 2.6592 2.68 16 0.45 0.3793 0.6228 0.8033 0.9497 1.0689 1.1686 123786 1.6207 1.8534 2.0661 2.2320 2.3161 2.3778 0.46 0.3890 0.6224 10.7947 0.9543 1.0895 1.2033 1.3333 1.5405 1.8284 2.0823 12.3263 2.3744 2.3823 0.47 0.4042 0.6433 0.7732 0.8993 1.0347

1. 1777 1.3344 1.5448 1.82'78

'2.0818 2.3216 2.4396 2.4968 0.48 0.4052 0.6732 0.8266 0.9309 1.0398 1.1520 1.3023 1.4931 1.7687 2.0094 2.3261 2.4629 2.5321 0.49 0.3875 0.6956 0.8538 0.9602 1.0723 1.1835 1.3075 1.4946 1.7659 2.0075 2.2467 2.3746 12.4558 0.50 03841 0.6926 0.8675 0.9826 1.0752 11.1755 1.3224 1.5107 1.7876 2.0424 2.3063 2.3401 12.2696 0.51 0.3716 0.6996 0.8857 1.0161 1.1259 11.2090 1.2783 1.4639 1.7374 1.9945 2.2737 2.3217 12.2588 0.52 10.3492 0.6595 0.8407 0.9784 1.0986 1.2068 1.2909 1.3604 1.5873 1.8301 2.0993 2.1515 12.1094 0.53 0.3204 0.6007 10.8199 0.9975 1.1455 1.2670 1.3618 1.4460 1.5818 1.7513 11.9116 1.9811 11.9706 0.54-0.3006 0.6022 0.8811 1.0535 1.1911 1.3097 1.4119 1.5276 1.7071 1.8988 2.0925 2.1050 12.0286 0.55 0.2845 0.6170 0.8930 1.0661 1.2309 1.3593 1.4558 1.5558 1.7439 1.9439 2.1547 2.1764 2.1023 0.56 0.2832 0.6010 0.8887 1.1224 1.3011 1.4401 1.54-79 1.6515 1.7694 1.9064 2.1214 2.1472 2.0779 0.57 0.2713 0.5754 0.8994 1.1347 1.3163 1.4592 1.5729 1.6858 1.8196 1.9433 2.0748 2.0847 2.0012 0.58 0.2552 0.5700 0.8837 1.1148 1.2950 11.4381

.1.5523 1.6686 1.8098 1.9396 2.0741 2.0878 2.0158 0.60 0.2441 0.5335 0.8206 1.0381 1.2106 1.3470 1.4550 1.5669 1.7094 1.8391 1.9731 1.9931 1.9425 0.62 0.2314 0.4927 0.7549 0.9567 1.1532 1.3181 1.4322 1.5150 1.6222 1.7210 1.8775 1.9145 1L.8254.

0.64 0.2167 0.4573 0.7054 0.9558 1.2129 1.4136 1.5509 1.6583 1.7963 1.9420 2.0786 2.1111.8665.

0.66 0.1918 0.4047 0.6456 0.9260 1.1790 1.3802_ 11.5222 11.6619 1.8401 2.0120 2.1757 2130 1 1.9446

.1

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: '38 of '349

~~~~~~~~~~~~~~~~~~Date 08/27/03 0.68 0.1847 0.3838 10.6068 0.8403 1.0684 1.2602 1.4086 J1.5405 1.7053I 1.8706 12.0531-2.0618 1.911(10 0.70 0.2076 0.3913 0.5981 0.8041 1.0039 1.1870 1.3723 1563 1.7859

.1.9744 2.1187 2.0290 1.8185 0.72 0.2181 0.4239 0.6275 0.8402 1.0563 1.2691 1.4732 1.6714 1.8909 2.0878 2.2446 2.1534 1.9292 0.74 0.2093 0.4157 0.6168 0.8230 1.0321 1.2355 1.4282 1.6143 11.8'212

'2.0101 2.1720 2.0951 1.880.4 0.76 0.1985 0.4014 0.5987 0.7980 1.0003 1.1975 1.3845 1.5660 11.7646 J1.9465 2.1094-2.0396 11.9054 0.78 0.1824 0.3756 0.5652 0.7543 0.9463 1.1344 1.3139 1.4876 1.6735 1.8435 12.0681 12.1593 12.0449 0.80 0.'17681: 20.3425-0.52r0

-09:6979 0.8827 1.0661-1.24357 1.4285.1:-6437 1.8546

-2.147 2.241-5--I 2.1227 0.82 0.1853 0.3331 0.4939 0.6749 0.8631 1.0487 1.2308 1.4205 1.6398 1.8535 2.1533 2.2515 2.1378 0.84 0.1938 0.3492 0.4932 0.6409 0.8231 1.0063 1.1884 1.31795 1.5996 1.8131 2.1166 2.2228 2.1183 0.86 0.1988 0.3604 0.5045 0.6421 0.7737 0.9436 1.1225 1.3118 1.5291 1.7397 2.0429 2.1571 2.0641 0.88 0.1978 0,3612 0.503 1 0.6359 0.7640 0.8832 1.0267 1.2085 1.4174 1.6188 1.9143 2.0332 1.9564 0.90 0.1915 0.3517 0.4883 0.6130 0.7337 0.8457 0.9527 1.0854 1.2799 1.4.671 1.7476 1.8696 1.8149 0.92 0.1849 0.3402 0.4708 0.5870 0.6992 0.8028 0.9007 1.0061 1.1547 1.3280 1.5934 1.7203 1.6898 0.94 0.1913 0.3587 0.5055 10.6282 0.7413 0.8457 0.9440 1.0473 1.1721 1.2920 1.4929 1.6814 1.8010 0.96 0.1974 0.3731 0.5312 0.6646 0.7884 0.9039 1.0136 1.1275 1.2630 1.34954 11.6104 1.7965 1.9067 0.98 0.2002 0.3805 0.5461 0.6876 0.8185 0.9416 1.0596 1.1813 1.3227 1.4619 11.6861 1.8699 1.9738 1.00 0.2000 0.3808 0.5500 0.6968 0.8321 0.9597 1.0833 1.2101 1.3529 1.4935 11.7209 1.9017 2.0023 1.05 0.2019 0.3742 0.5297 0.6715 0.7974 0.9052 1.0176 1.1426-1:2749 1.4000 1.6085 1.7738 1.8703 1.0 0.2altr- -03873 0.5588

-0.7084 -0.8430

'C.9OMO

'.- 0649 1.1663 1.2983 11.4134

-1.3164 1.6679 1.7194 1.15 0.2036 0.3927 0.5643 0.7132 0.8497 10.9737 1.0877 1.2237 1.3667 1.4937 1.6766 1.7820 1.8383 1.20 0.1865 0.3567 0.5145 0.6597 0.8041 0.9424 1.0778 1.2166 1.3629 1.4952 1:6882 1.8011 1.8588 1.25 0.1884 0.3674 0.5210 0.6381 0.7749 0.9114 1.0447 1.1806 1.3244 1.4561 1.6506 1.7652 1.8222 1.30 0.1994 0.3874 0.5486 0.6736 0.7790 0.8894 1.0210 1.1543 1.2949 1.4250 1.6193 1.7351 1.7928 1.35 0.1908 0.3878 0.5678 0.7111 0.8288 0.9255 1.0067 1.1160 1.2524 1.3795 11.5725 1.6896 1.7488 1.40 0.1735 0.3527 0.5352 0.6910 0.8207 0.9272 1.0146 11.0910 1.2032 1.3267 1.5163 1.6326 1.6921 1.45 0.1663 0.3498 0.5325 0.6911 0.8-226 0.9530 1.0805 1.1973 1.3039 1.3901 1.5004 1.6151 1.6743 1.50 0.1470 0.3111 0.4730 0.6101 0.7389 0.8738 -

0.9965 1.1064 1.2087 1.3292 1.5153 1.6305 1.6917 1.55 0.1311 0.2686 0.4114 0.5528 0.6899 0.8216 0.9490 1.0741 1.1998 1.3174 1.5020 1.6196 1.6859 1.60 0.1257 0.2575 0.3938 0.5414 0.6902 0.8338 0.9691 1.0936 1.2062.1.2964

-1.4386 1.5594 1.6315 1.65 0.1214 0.2519 0.4029 0.5601 0.7151 0.8647 1.0062 1.1375 1.2583 1.3556 1.4490 1.4865 11.5628 1.70 0.1155 0.2428 0.3889 0.5415 0.6930 0.8406 0.9818 1.1142 11.2-372 1.3378 1.4404 1.4645 11.5318 1.75 0.1107 0.2355 0.3733 0.5227 0.6722 0.8199 0.9632 11.0985 1.2234 1.3273 1.4555 1.5033 11.5559 1.80 0.1068 0.2310 0.3681 0.5124 0.6583 0.8044 0.9487 1.0870 1.2157 1.3280 1.4767 1.5284 11.6062 1.85 0.1064 0.2198 0.3407 0.4767 0.6142 0.7515 0.8864 1.0157 1.1366 1.2420 1.4346 1.5639 11.6411 1.90 0.1043 0.2167 0.3370 0.4622 0.5898 0.7197 0.8520 0.9851 1.1159 1.2364 1.4330 1.5593 1.6366 1.95 10.0995 0.2081 0.3243 0.4461 0.5706 0.6974 0.8265 0.9560 1.0833-

-12000 1.3895 1.5322 1.6090 2.00 0.0931 0.1956 0.3050 0.4197 0.5373 0.6571 0.7790 0.9015 1.0226 1.1339 1.3616 1.5160 1.5997 2.05 0.0855 0.1801 0.2836 0.3944 0.5082 0.6249 0.7521 10.8863 1.0179 11.1415 1.3407 1.4782 1.5560 2.10 0.0774 0.1635 0.2585 0.3619 0.4711 10.5864 0.7081 10.8345 0.9635 11.0891 1.3141 1.4543 1.5073 2.15 0.0696 0.1474 0.2316 0.3257 0.4252 10.5307 0.6422 0.7576 0.8738 10.9848 11.1790 1.3309 11.4676 2.20 0.0638 0.1331 0.2120 0.3000 0.3920 0.4883 0.5886 0.6902 0.7907 0.8898 1.0950 1.3070 1.4863 2.25 0.0609 0.1271 0.1974 0.2806 0.3680 0.4598 0.5556 0.6533 0.7510 0.8477 1.0705 1.3078 1.4841 2.30 0.0583 0.1214 0.1886 0.2621 0.3450 0.4323 0.5240 0.6184 0.7139 0.8090 1.0550 1.2833 1.4551 2.35 0.0570 0.1182 0.1824 0.2487 0.3223 0.4053 0.4933 0.5847 10.6782 0.7823 1.0187 1.2358

-1.4050 2.40 0.0539 0.1125 10.1746 0.2388 0.3058 0.3792 0.4640 0.5522 0.6425 10.7432 10.9643 1.1712 1.3431 2.50 0.0463 0.0966 0.1500 0.2054 0.2645 0.3324 0.4079 0.4863 0.5671 10.6479 10.8307 1.0247 1.94 2.60 0.0480 0.0993 0.1547 0.2148 0.2789 10.3472 0.4200 0.4967 0.5769 10.6602 10.8435 11.0376 1237 2.70 0.0415 0.0867 0.1353 0.1884 0.2460 0.3085 0.3765 0.4493 0.5266 10.6065 10.7845 0.9781 1.1742 2.80, 0.0381 0.0787 0.1230 0.1702 0.2208 0.2768 0.3368 10.4005 0.4673 10.5373 0.6958 0.8707 1.0526 2.90 0.0365 0.0750

-0.1150 0.1558 0.1972 0.2401 0.2870 10.3393 0.3948 0.4535 0.5937 0.7450 0.8942 3.00 0.0353 0.0728 0.1119 0.1518 0.1923 0.2337 0.2770 0.3237 0.3762 0.4334 0.5651 0.7093 0.497 3.10 0.0342 0.0706 0.1086 0.1475' 0.1868 0.2271 0.2688 0.3122 0.3585 0.4100 0.5319 0.6690 0.8069 3.20 0.0322 0.0666 0.1027 0.1397 0.1772 0.2155 0.2551 0.2961 0.3389 0.3850 0.4950 0.6226 0.7533 3.30 0.0304 0.0622 0.0947 0.1289 0.1636 0.1991 0.2359 0.2740 0.3151 0.3591 0.4561 0.5701 0.6900 3.40 0.0309 0.0636

-0.0974 0.1318 0.1669 0.2033-0.2-416 0.2822 0.3252 10.3704 0.4704 0.5775 10.6851 3.50 0.0297 0.0616 0.0950 0.1294 0.1646 0.2009 0.2390 0.2793 0.3221 0.3671 0.4670 0.5753 0.6856 3.60 0.0252 0.0526 0.0820 10.1125 0.1438 0.1761 0.2101 0.2461 0.2843 0.26 0.4145 0.5128 0.6139 3.70 0.0210 0.0431 0.0679 10.0945 0.1-223 0.1516 0.1825 0.2149 0.2486 0.83 0.3566 0.4316 0.5186 3.80 0.0196 0.0401 0.0625 0.0871 0.1128 0.1400 0.1687 0.1989 0.2304 0.67 0.3314 0.4021 0.4737 3.90 0.0200 10.0399 10.0608 0.0846 10.1096 10.1361 0.1642 0.1938 0.2248 0.2566 0.3248 0.3959 0.4687 4.00 0.0203 0.0408 0.0614 0.0824 0.1042 0.1272 0.1539 0.1821 0.2118 0.2425 0.3095 0.3811 0.4557 4.10 0.0190 0.0386 0.0587 0.0794 0.1007 0.1226 0.1450

0. 1677 0.1905 0.2133 0.2692 0.3370 0.4094 4.20 0.0172 0.0336 0.0510 0.0690 0.0876 0.1069 0.1267 0.1469 0.1674 0.1916 0.2482-0.3079 0.3658 4.30 0.0181 0.0357 0.0524 0.0680 0.0832 0.1005 0.1203 0.1418 0.1649 0.1895 0.2453 (0.3048 0.3631 I4.40 0.0185 I0.0368 0.0544 0.0711 0.0874 0.1034 0.1194 0.1385 0.1610 0.1850 0.2394 10.2980 0.3559 I--

Calc Number: GEO.HBIP.0'.02 Rev Nfumber: 0 Sheet Number: 3 9 (if 349 Date: 08/27/03 4-30 1 0.0183 1 0.36-7 1 0-0547 1 0.07IR 1 0°0g:

O.t53 1 0.1219_

0.1386 1 0.1552 1 0.1778 1 0.2303 0.2872 0.3440 4.60 1 0.0177 1 0.0356 1 O.OS33 O.0704 I tn.oM 005 I_80.1251 0.1447 1 0.1646

.223 0229

_0.28727 0.3291 1 4.70 0.0166 0.0336 0.0505 0.0670 0.0845 0.1030 0.1221 0.1416 0.1616 0.1815 0.2216 0.2616 10.3152 4.80 0.0153 _0.0314 0.0483 0.06s4 0.o0826 0.1 000 0.1174 0.1352 0.1533 0.170S 0.2027 0.2444 0.2981 4.90 0.0147 _0.0304 0.0468 0.0635 0.0s03 0.0973 0.1144 0.1319 0.1498 0.1671 0.1990 0.2274 0.2773 s.oo 0.0141 0.0291 U 449 0.0610 o.o m2 0.0937 0.1103 0.1273

'0.1447 0.1617 0.1931-0.2211 0.2552 0.~l o0133,0.0275-

-0.0425 0-0580-

-0.0735 0.0892

--.1052F' 0.12i6-0.13847 A-1548 0,1855 0;X129 0.23S4 5.20 0,0132 0.0269 0.0410 0.0555 0.0704 0.0859 0.1018 0.1191 0.1348 0.1515 0.1854 0.219 1 0.2530 5.40 0.0124 0.0257 0.0394 0.0536 0.0683 0.0836 0.0995 0.1160 0.1329 0.1501 0.1sss 0.2220 0.2597 3.60 0.0105 0.0215 0.0325 0,0433 0.0540 0.0653 0.0774 0.0892 0.1007 0.1118 0.1387 0.16s5

0. 1990 3.80 0.0096 0.0197 0.0302 0.0409 0.0517 0.0626 0,0735 O.OW4 0.0958 0.1070 0.1290 0.1490 0.1673 6.00 0.00 89 0.01S4 0.0283 0.038S?

0.0491 0.0597 0.0705 0.0813 0.0923 0.1035 0.1257 0.1466 0.166 6.20 0.0086 0.0172 0.0265 0.0364 0.0464 0.0565 0.0669 0.0'774 0.0881 0.0990 0.1211 0.1428 0.1641 6.40

'0.0085 0.0170 0.0256 0.0346 0.0439 0.0536 U.635 0.0738

'0.0943 0.0951 0.1181 0.1416

-0.1642 6.60 0.0087 0.0174

-0.0262 0.0350 0.0437 0.0525 U.612 0.0710 0.0812 0.091i7 0.1144 0.1379 0.160S 6.80 0.00SI 0.01 64 0.0248 0.0333 0.0418 0.0503 0,0589 0.0675 0.0764 0.0851 0.1042 0.1266 0.1486 7.00 0.0075 0.0153 0.0231 0.0312 0.0395 0.0480 0,0567 0.0657 0.0747 0.0838 0.1021 0.1200 0.1376 7.20 0.0073 0.0148 0.0221 0.0300 0.0391 0.0464 0.0551 0.0640 0.0731 0.0824 0.1013 0.1203 0.1392 TO4

-0.0071 0.0143-btb Is 0.0'290 0.0360-0.0429 0.040YJ- 0.0560 0.0623 0.0695 0.0860 6.-ei36--T6

-. 1212 7.60 0.0065 0.0133 0.0201 0.0270 0.0337 0.0405 0.0474 10.0540 0.0604 0.0666 0.0786 0.0951 0.1ll 8 7.80 0.0055 0.01 14 0.0174 0.0236 0.0299 0.0363 0,0427 0.0490 ~0.0550 0.0609 0.0719 0.0853 0.1007 8.00 0.005 1 0.0103 0.0155 0.0207 0.0260 0.0313 0.0366 0.0418 0.0470 0.0521 0.0646 0.0782 0.09'25 s.50 0.0052 0.0104 0.0157 0.0210 0.0262 0.0315 0.0367 0.0419 0.0472 0.0525 0.0630 0.07n27 0.0817 9.00 0.0046 0.0093 0.0142 0.0190 0.0239 0.0288 0.0337 0.0387 0-0437 0.0488 0.0590 0.0691 0.07F9 9.50 0.0042 o.oo S5 0.0129 0.0!73 0.0217,0.02.1 0.0306 0.03 50 0.03 95 0-0439 0.0s25 0.0612 0.0703 1.00 0.0038 0.0075 0.0113 1 0.0l53 0.0194 10.0235 0.0277 0.0320 0.0363 0.0405 0.04ss 0.0571 0.0651

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 40 of 349 Date: 08/27/03 Table 6-7a. Soil Spectra for M=6.0. Set 1. Lower Vs Soil Profile (see) 0.1 0.UR 0.3z 0.4g 0.S1Z 0.6 0.7_s I 0.g 1 0.9g I R I2 SE 1 I4c i1.6g Per..-.____

r--_

l08j0._

1+/-2 l114c 0.01 0.1565 0.2767 0.3853 0.4926 1 0.5936 0.6749 0.7382 1 0.7876 1 0.8266 0.8566 0.8956 0.9147 0.9226 0.03 0.1627 0.2827 0.3914 0.497 10.5999 0.6815 0.7448 1 0.7946 10.8335 10.8630 10.9019 0.9205 0.9280 0.04 4 0.1740 0.2950 0.4014 015 06 8 4 0.6071 0.6881 0

8008 0.8396 0.8690 0.9076 0.9258 0.9331 0.05 0.1896 0.3153 0.4204 0:5224

0. 62 11 0.7004 0.7619 0.8107 0.8489 1 0.8777 0.9154 0.9325 1 0:9391 1-
-s l;

0.06 0.2078 0.3365 0.4435 0.5438 10.6399 0.7170 0.7792 0.8268 0.8640 0.8918 0.9274 0.9429 0.9483 0.07 0.2041 0.31S1 0.4188 0.5137 0.6143 0.7039 0.7746 0.8283 0.8691 0.8988 0.9362 0.9537 0.9589 0.08 0.2572 0.3872 0.4931 0.5979 0.6970 0.7716 0.S277 0.8683 0.9006 0.9253 0.9545 0.9674 0.9715 0.09 0.2767 0.4415 0.5451 0.6425 0.7454 0.8231 0.8805 0.9228 0.9534 0.9760 0.9990 1.0045 1.OOI1 0.10 0.3476 0.5100 0.5523 0.5661 0.6823 0.7769 0.8480 0.9017 0.9416 0.9688 1.0007 1.0103 1.0098 0.11 0.3542 0.5588 0.6183 0.6096 0.6967 0.7958 0.8676 0.9220 0.9612 0.9899 1.0204 l.0294 l.0292 0.12 0.3879 0.6298 0.6847 0.6635 0.7560 0.8480 0.9118 0.9596 0.9933 1.0159 1.0407 1.0474 1.0474 0.13 0.3758 0.5928 0.7121 0.8478 0.9690 1.0461 1.0974 1.1294 1.1495 1.1586 1.1626 1.1545 1.1418 0.14 0.3939 0.6316 0.7801 0.9209 1.0507 1.1334 1.1831 1.2148 1.2347 1.2408 1.2392 1.2212 1.2043 0.15 0.4366 0.6370 0.7446 0.8129 0.9237 1.0118 1.0672 1.1063 1.1373 1.1546 1.1712 1.1677 1.1610 0.16 0.4635 0.6966 0.8500 0.9467 0.9767 0.9718.

0.9827 1.0152 1.0530 1.0860 1.1270 1.1426 1.1475 0.17 0.5043 0.8048 0.9579 1.0094 1.0624 1.0723 1.0811 1.1067 1.l424 1.1743 1.2059-1.2143 1.2340" 0.18 0.5487 0.8960 1.0684 1.1284 1.1315 1.1037 1.1327 1.1863 1.2386 1.2860 1.3561 1.3944 1.4343 0.19 0.4878 0.8118 0.9849 1.1100 1.2009 1.2625 1.3186 1.3726 1.4223 1.4713 1.5389 1.5733 1.6117 0.20 0.5263 0.8488 1.0641 1.2083 1.3111 1.3757 1.4284 1.4842 1.5384 1.5834 1.6517 1.6909 1.7355 0.21 0.5134 0.8283 1.0401 1.1850 1.2818 1.3444 1.4001 1.4580 1.5174 1.5684 1.646S 1.6952 t.7503 0.22 0.5086 0.8298 1.0456 1.1858 1.2783 1.3453 1.4056 1.4701 1.5313 1.5825 1.6692 1.7243 1.7856 0.23 0.5082 0.8295 1.0319 1.1596 1.2578 1.3303 1.3952 1.4584 1.5163 1.5719 1.6653 1.7265 1.7995 0.24 0.5286 0.8636 1.0732 1.2185 1.3339 1.4088 1.4744 1.5371 1.5979 1.6570 1.7573 1.8255 1.9008 0.25 0.5331 0.8800 1.0985 1.2516 1.3689 1.4432 1.5041 1.5664 1.6255 1.6837 1.7843 1.8513 1.9320 0.26 0.5328 0.8634 1.0828 1.2407 1.3579 1.4283 1.4862 1.5416 1.5978 1.6481 1.7426 l.8096 1.8960 0.27 0.5450 0.8902 1.0744 1.1815 1.2868 13506 1.4033 1.4S29 1.5533 1.6182 1.7151 1.7460 1.7808 0.28 0.5200 0.8639 1.0598 1.1785 1.2650 1.3160 1.3803 1.4522 1.5199 1.5845 1.6898 1.7387 1.7658 0.29 0.4987 0.8474 1.1655 1.3188 1.3588 1.3967 1.4839 1.5847 1.6797 1.7682 1.9164 1.9898 2.0258 0.30 0.5047 0.S796 1.2443 1.4015 1.4342 1.4662 1.5550 1.6701 1.7808 1.8873 2.0563 2.1365 2.1788 0.31 0.5149 0.9104 1.1747 1.3322 1.4129 1.4716 1.5639 1.6194 1.6457 1.663E 1.8293 1.9052 1.9465 0.32 0.5142 0.9166 1.1849 1.3434 1.4711 1.6333 1.7363 1.8006 1.8336 1.8451 1.8512 1.9032 1.9302 0.33 0.4925 0.8861 1.1481 1.3745 1.6349 1.8149 1.9303 2.0016 2.0430 2.0639 2.0752 2.1320 2.1659 0.34 0.4353 0.7905 1.1299 1.4626 1.7386 1.9324 2.0603 2.1452 2.1995 2.2329 2.2466 2.3135 2.3558 0.35 0.3839 0.7644 1.1337 1.4718 1.7552 1.9585 2.0991 2.1979 2.2665 2.3139 2.3533 2.4163 2.4649 0.36 0.3704 0.7404 1.1076 1.4458 1.7357 1.9466 2.1000 2.2135 2.2965 2.3567 2.4200 2.4875 2.5400 0.37 0.3525 0.7121 1.0727 1.4113 1.7064 1.9262 2.0931 2.2204 2.3184 2.3919 2.4761 2.5523 2.6109 0.38 0.3300 0.6746 1.0262 1.3627 1.6602 1.8896 2.0692 2.2098 2.3227 2.4093 2.5160 2.6042 2.6668 0.39 0.3113 0.6263 0.9645 1.2939 1.5916 1.8295 2.0201 2.1756 2.3001 2.4008 2.5328 2.6253 2.6928 0.40 0.3027 0.5952 0.8914 1.2097 1.5049 1.7493 1.9523 2.1200 _2.2607 2.3747 2.5339 2.6167 2.6903 0.41 0.2914 0.5727 0.8577 1.1394 1.4126 1.6633 1.8768 2.0589 2.2138 2.3431 2.5299 2.6210 2.6844 0.42 0.2784 0.5469 0.8198 1.0909 1.3507 1.5822 1.8202 2.0i31 2.2338 2.3773 2.5876 2.7154 2.8149 0.43 0.2648 0.5201 0.7807 1.0432 1.2989 1.6116 1.9218 2.1714 2.3634 2.5118 2.7278 2.8597 2.9681 0.44 0.2492 0.4894 0.7377 0.9908 1.2414 1.5284 1.8281 2.0654 2.2710 2.4729 2.7391 2.8490 2.9129 0.45 0.2541 0.4839 0.6941 0.9265 1.1700 1.4510 1.7695 2.0645 2.3200 2.5244 2.8001 2.9151 2.9737 0.46 0.2589 0.4932 0.7086 0.9026 1.0851 1.3392 1.6336 1.9179 2.1775 2.4004 2.7247 2.8835 2.9704 0.47 0.2610 0.4971 0.7147 0.9123 1.1002 1.2655 1.5155 1.7871 2.0378 2.2558 2.5783 2.7608 2.9439 0.48 0.2602 0.4960 0.7139 0.9122 1.1012 1.2690 1.4286 1.6643 1.8906 2.0974 2.4415 2.6771 2.8708 0.49 0.2575 0.4911 0.7070 0.9042 1.0934 1.2607 1.4208 1.5738 1.7709 1.9751 2.3195 2.5610 2.7608 0.50 0.2540 0.4841 0.6967 0.8912 1.0787 1.2457 1.4038 1.5556 1.6985 1.8367 2.1760 2.4198 2.6212 0.51 0.2497 0.4757 0.6844 0.8757 1.0607 1.2253 1.3S33 1.5339 1.6750 1.8061 2.0314 2.2566 2.4573 0.52 0.2559 0.4655 0.6694 0.8566 1.0389 1.2020 1.3574 1.5065 1.6471 1.7780 2.0031 2.1756 2.3690 0.53 0.2698 0.4596 0.6524 0.8346 1.0127 1.1727 1.3270 1.4747 1.6136 1.7431 1.9678 2.1428 2.3355 0.54 0.2780 0.4769 0.6352 0.8078 0.9812 1.1385 1.2892 1.4348 1.5725 1.7015 1.9251 2.0994 2.2938 0.55 0.2704 0.4654 0.6496 0.8035 0.9443 1.0968 1.2449 1.3876 1.5228 1.6493 1.8707 2.0455 2.2401 0.56 0.2509 0.4518 0.6381 0.7935 0.9362 1.0483 1.1922 1.3312 1.4629 1.5872 1.8050 1.9784 2.1721 0.57 0.2270 0.4351 0.6201 0.7746 0.9155 1.0260 1.1322 1.2666 1.3947 1.5158 1.7286 1.8984 2.0897 0.58 0.2197 0.425S 0.6111 0.7641 0.9030 1.0116 1.1026 1.196S 1.3200 1.4364 1.6427 1.8094 1.9962 0.60 0.2153 0.4208 0.6047 0.7531 0.8921 1.0140 1.1087 1.1834 1.2429 1.3014 1.4584 1.6140 1.7900 0.62 0.1987 0.3865 0.5531 0.7103 0.8635 0.9904 1.0914 1.1712 1.2335 1.2870 1.3819 1.4788 1.6324 0.64 0.1742 0.3383 0.4967 0.6518 0.8042 0.9342 1.0376 1.1166 1.1768 1.2257 1.3076 1.3899 1.5280 0.66 0.1667 0.3251 0.4828 0.6460 0.8084 0.9465 1.0524 1.1306 1.1871 1.2303 1.2974 1.3665 1.4939

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 41 of 349 Date: 08127/03 0.68 0.1713 0.3396 0.51 17 0.6919 0.R688 1.0149 11.235 1.2007 1.253271.290-7 1.3426 1.3979 1.5211 0.70 0.1728 0.3488 0.5296 0.7158 0.8958 1.0405 j1.1439 1.2140 1.2576 I1.2840 I1.3136 1.3514 1.4669 0.72 0.1580 0.3252 0.4967 0.6687 0.8315 0.9578 1.0427 1.1216 1.2126 1.2845 1 1.3561 1.3891 1.4762 0.74 0.1257 0.2637 0.4057 0.5570 0.7272 0.9012 1.0655 1.2029 1.3138 1.3974 1.4845 1.4961 1.5463 0.76 0.1177 0.2439 0.3856 0.5396 0.7139 0.8990 1.0678 1.2112 1.3281 1.4174 1.5118 1.5245 1.5781 0.78 0.1224 0.2397

-0.3631 0.4966 0.6674 0.8423 1.0041 1.142-7 1.2567 1.3440 1.4352 1.4776 1.5881 C1IRO 0.1244

.0.2-433--

0.3656 0.4955 0D6273 0.7557.

-.0:857 1.0108 1.1,138.

p1-l.1925..

1.3502 -1.4615 1.5754 0.82 0.1244 0.2432 0.3636 0.4896 0.6165 0.7399 0.8578 0.9680 1.0703 1.1637 1.3195 1.4317 1.5473 0.84 0.1233 0.2409 0.3590 0.4810 0.6032 0.7215 0.8349 0.9412 1.0402 1.1310 1.2847 1.3978 1.5145 0.86 0.1217_

0.2377 0.3534 0.4719 0.5900 0.7039 0.8130 0.9157 1.0118 1.1004 1.2519 1.3660 1.4836 0.88 0.1200 0.2346 0.3481 0.4638 0.5784 0.6 8 855 0.7940 0.8937 0.9875 1.0747 1.2250 1.3402 1.4588 0.90 0.1185 0.2317 0.3435 0.4570 0.5688 0.6758 0.7787 0.761 0.9681 1.0542 1.2043 1.3207 1.4403 0.92 0.1170 0.2289 0.3394 0.4509 0.5604 0.6652 0.7658 0.8616 0.9525 1.0378 1.1878 1.3052 145 0.94 0.1154 0.2261 0.3353 0.4451 0.5527 0.6556 0.7544 0.8489 0.9388 1.0234 1.1731 1.2913 1.4128 0.96 0.1138 0.2232 0.3309 0.4391 0.5451 0.6462 0.7434 0.8365 0.9255 1.0094 1.1584 1.2771 1.3992 0.98 0.1120 0.2199 0.3261 0.4327 0.5371 0.6365 0.7322 0.8239 0.9116 0.9947 1.1428 1.2621 1.3848 1.00 0.1099 0.11 0.3208 0.4258 0.5286 0.6263 0.7205 0.8107 0.8971 0.9791 1.1265 1.2459 1.3686 1.05 0.1041 0.2054 0.3057 0.4065 0.5052 0.5988 0.6888 0.7753 0.8587 0.9384 1.0829 1.2019 1.3244

- ~1:-10 0.0974

0. 1931V 0-2886 0.3850-o-.O' 0.5694 0-6558-V 0.7389 0.8194-t. 0.8967 1.0380

-. 1. I560r 1.2772 1.15 0.0902 0.1798 0.2703 0.3626 0.4536 0.5404 0.6236 0.7036 0.7810 0.8556 0.9931 1.1096 1.2282 1.20 10.0877 0.1717 0.2569 0.3448 0.4319 0.5rs5 0.5954 0.6719 0.7461 0.8176 0.9506 1.0647 1.1794 1.25 0.0850 0.1661 0.2473 0.3307 0.4137 0.4937 0.5702 0.6434 0.7144 0.7831 0.9117 1.0229 1.1333 1.30 0.0823 0.1606 0.2374 0.3170 0.3962 0.4728 0.5464 0.6169 0.6855 0.7519 0.877 0.9858 1.0918 1.35 0.0844 0.1681 0.2472 0.3206 0.3879 0.4541 0.5253 0.5938 0.6605 0.7253 10.8478 0.9550 1.0572 1.40 0.0858 0.1711 0.2535 0.3309 0.4022 0.4646 0.5199 0.5762 0.6412 0.7044 0.8245 0.9306 1.0294 1.45 0.0856 0.1701 0.2530 0.3320 0.4054 0.4702 0.5285 0.5814 0.6292 0.6874 0.8050 0.9097 1.0061 1.50 0.0836 0.J656 0.2468 0.3257 0.3996 0.4654 0.5252 0.5798 0.6297 0.6750 0.7865 0.8896 0.9840 1.55 0.0801 0.1587 0.2368 0.3141 0.3876 0.4538 0.5144 0.5702 0.6218 0.6690 0.7668 0.8678 0.9603 1.60 0.0758 0.1511 0.2259 0.3011 0.3741 0.4415 0.5035 0.5608-0.6140 0.6631 0.7477 0.8424 0.9328 1.65 0.0726 0.1466 0.2195 0.2925 0.3642 0.4315 0.4939 0.5519 10.6061 0.6565 0.7445 0.8135 0.9006 1.70 0.0694 0.1408 0.2117 0.2825 0.3525 0.4193 0.4819 0.5404 0.5953 0.6467 10.7376 0.8099 0.8758 1.75 0.0653 0.1335 0.2022 0.2708 0.3385 0.4037 0.4655 0.5237 0.5789 0.6309 0.7247 0.8016 0.8'706 1.80 0.0610 0.1251 0.1905 0.2625 0.3377 0.4117 0.4810 0.5448 0.6034 0.6567 0.7482 0.8194 0.8853 1.85 0.0573 0.1201 0.1874 0.2586 0.3316 0.4027 0.4689 0.5337 0.5970 0.6557 0.7594 0.8437 0.9197 1.90 0.0508 0.1065 0.1688 0.2361 0.3067 0.3781 0.4464 0.5101 0.5693 0.6239 0.7192 0.7963 0.8672 1.95 0.0472 0.0985 0.1521 0.207~8 0.2660 0.3274 0.3893 0.4489 0.5064 0.5612 0.6618 0.7456 0.8171 2.00 0.0444 0.0925 0.1432

0. 1957 0.2493 0.3072 0.3661 0.4232 0.4785 0.53 17 0.6306 0.7152 0.7889 2.05 0.0418 0.0860 0.1337 0.1832 0.2338 0.2847 0.3386 0.3925 0.4454 0.4971 0.5955 0.6826 0.7588 2.10 0.0390 0.796 0.1236 0.1703 0.2186 0.2684 0.3197 0.3717 0.4230 0.4,733 0.5707 0.6611 0.7429 2.15 0.0363 0.0741 0.1134 0.1580 0.2067 0.2588 0.3108 0.3620 0.4121 0.4611 0.5552 0.6420 0.7210 2.20 0.0336 0.0687 0.1082 0.1523 0.1996 0.2497 0.2998 0.3491 0.3973 0.4442 0.5342 0.6167 0.6923 2.25 0.0310 0.0652 0.1039 0.1460 0.1910 0.2386 0.2863 0.3332 0.3791 0.4238 0.5284 0.6350 0.7344 2.30 0.0319 0.0668 0.1049 0.1459 0.1901 0.2385 0.2896 0.3426 0.3971 0.4527 0.5668 0.6799 0.7846 2.35 0.0324 0.0679 0.1066 0.1486 0.1937 0.2429 0.97 0.3483 0.4035 0.4599 0.5754 0.6898 0.7957 2.40 0.0308 0.0646 0.1016 0.1419 0.1854 0.2327 0.2826 0.3342 0.3875 0.4420 0.5545 0.6674 0.7724 2.50 0.0257 0.0536 0.0835 0.1153 0.1503 0.1888 0.2302 0.2732 0.3176 0.3639 -0.4618 0.5617 0.6540 2.60 0.0245 0.0506 0.0785 0.1082 0.1393 0.1717 0.2050 0.2393 0.2748 0.3118 10.3907 0.4763 0.5629 2.70 0.0228 0.0473 0.0736 0.1021 0.1322 0.1640 0.1967 0.2302 0.2649 0.3009 0.3775 0.4598 0.5421 2.80 0.0209 0.0432 0.0670 0.0922 0.1191 0.1480 0.1781 0.2090 0.2410 0.2741 0.3448 0.4207 0.4960 2.90

-0.0179 0.0372 0.0580 0.0802 0.1036 0.1287 0.1549 0.1818 0.2098 0.2387 0.3005 0.3670 0.4329 3.00 0.0 1 O 0.0335 0.0518 0.0714 0.0920 0.1134 0.1352 0.1576 0.1809 0.2052 0.2581 0.3163 0.3758 3.10 0.0146 0.0301 0.0465 0.0640 0.0826 0.1020 0.1219 0.1421 0.1630 0.1848 0.2317 0.2834 0.3366 3.20 0.013-3 0.0275 0.0429 0.0594 0.0767 0.0949 0.1136 0.1326 0.1520 0.1719 0.2136 0.2591 0.3063 3.30 0.0123 0.0254 0.0394 0.0545 0.0706 0.0876 0.1050 0.1227 0.1407 0.1592 0.1976 0.2391 0.2819 3.40 0.0120 0.0245 0.0375 0.0511 0.0652 0.0797 0.0955 0.1118 0.1283 0.1452 0.1803 0.2179 0.2567 3.50 0.0110 0.0225 0.0346 0.0473 0.0606 0.0746 0.0890 0.1037 0.1188 0.1343 0.1668 0.2014 0.2371 3.60 0.0100 0.0201 0.0309 0.042.3 0.0546 0.0676 0.0810 0.0947 0.1087 0.1228 0.1515 0.1841 0.2196 3.70 0.0097 0.0194 0.0295 0.0408 0.0527 0.0656 0.0790 0.0927 0.1066 0.1209 0.1501 0.1799 0.2088 3.80 0.0095 0.0190 0.0285 0.0385 0.0499 0.0623 0.0754 0.0888 0.1026 0.1166 0.1457 0.1756 0.2046 3.90 0.0092 0.0184 0.0276 0.0369 0.0469 0.0586 0.0710 0.0839 0.0971 0.1108 0.1391 0.1684 0.1968 4.00 0.0087 0.0176 0.0264 0.0353 0.0445 0.0547 0.0661 0.0782 0.0908 0.1038 0.1310 0.1592 0.1866 4.10 0.0081 0.0164 0.0248 0.0332 0.0418 0.0511 0.0613 0.0724 0.0840 0.0962 0.1218 0.1485 0.1745 4.20 0.0077

-0.015-8 0.0240 0.0326 0.0414 0.0506 0.0599 0.0692 0.0784 0.0880 0.17 016 0.1609 4.30 0.0075 0.0154 0.0235 0.0320 0.0407 0.0497 0.0589 0.62 0074 006 0.147 01236 0.1459 4.40 0.0072 I~0.0148 0.0228 0.0310 0.0395 0.0484 0.0574 0.0664 0.0755 0.08.46 0.05 010 0.1373 I

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 42 of 349 Date: 08/27/03 4.50 0.0068 0.0141 0.0218 0.0297 0.0379 0.0465 l 0.0552 0.0640 0.0729 0.0817 l 0.0993 0.1165 0.1334

-460.

0.0064 0.0132 0.0205 0.02SO 0.0359 0.0441 0.0524 0.0609 0.0694 0.0780 i0.0950 0.1117 0.128S 4.70 0.0059 0.0122 0.0190 0.0261 0.0335 0.0412 0.0491 0.0572 0.0653 0.0735 0.0898 0.1059 0.1217 4.80 0.0053 0.0111 0.0173 0.0239 0.0308 0.0380 0.0454 0.0530 0.0606 0.0634 0.0839 0.0993 0.1144 4.90 0.0052 0.0104 0.0158 0.0215 0.0278 0.0345 0.0414 0.0484 0.0556 0.0628 0.0774 0.0920 0.1063 5.00 0.0051 0.0102 0.0155 0.0210 0.0267 0.0325 0.0383 0.0442 0.0502 0.0569 0.0705 0.0843 0.0977 5.10-0.0050 0.0101-

-0.0153 0.0205 0.0260- 1 --f0.0316-0.0373 -..0.,0430 0.0488 0.0547 -.0.0667 0.0794 0.0928 5.20 0.0049 0.0100 o0.0152 0.0204 0.0255 0.0307 0.0362 0.0417 0.0473 0.0530 0.0647 0.0___I 0.0901 5.40 0.0047 0.0095 0.0144 0.0195 0.0245 0.0294 0.0342 0.0389 0.0441 0.0494 0.0603 0.0719 0.0842 5.60 0.0043 0.0087 0.0132 0.0179 0.0226 0.0272 0.03 18 0.0363 0.0407 0.0455 0.0556 0.0664 0.0778 5.80 0.0038 0.0077 0.0117 0.0159 0.0201 0.0244 0.0286 0.0327 0.0370 0.0414 0.0507 0.0606 0.0711 6.00 0.0033 0.0067 0.0102 0.0 139 0.0177 0.0216 0.0256 0.0296 0.0337 0.0377 0.0459 0.0548 0.0644 6.20 0.0029 0.0053 0.0089 0.0121 0.0155 0.0190 0.0226 0.0263

-0.0299 0.0335 0.0409 0.0491 10.0577 6.40 0.0026 0.0052 0.0078 0.0106 0.0136 0.0168 0.0200 0.0231 0.0263 0.0295 0.0362 0.0436 0.0514 6.60 0.0026 0.0051 0.0076 0.0100 0.0122 0.0147 0.0175 0.0203 0.0231 0.0260 0.0319 0.0385 0.0454 6.80 0.0025 0.0050 0.0074 0.0097 0.0119 0.0138 0.0157 0.0178 0.0202 0.0227 0.0280 0.0338 0.0393 7.00 0.0024 0.0048 0.0071 0.0093 0.0115 0.0134 0.0153 0.0171 0.0190 0.0210 0.0255 0.0307 0.0364 7.20 0.0023 0.0046 0.0068 0.0090 0.0110 0.0129 0.0148 0.0166 0.0184 0.0203 0.0247 0.0298 0.0353 7.40.*0.9022 0.0044 0.0065'*

0.0086 0.0106-- s0.0124 0.0142 r 00 160 0.0177 0.0196.' "238 0.0287.

0M0340 7.60 0.0021 0.0042 0.0062 0.0082 0.0101 0.0119 0.0136 0.0153 0.0170 0.01S 0.0228 0.0276 0.0326 7.80 0.0020 0.0040 0.0059 0.0078 0.0096 0.0113 0.0130 0.0146 0.0163 0.010 0.0218

'0.0264 0.0312 8.00 0.0019 0.0038 0.0056 0.0074 0.0092 0.0108 0.0124 0.0139 0.0155 0.0171 0.0208 0.0251 0.0297 8.50 0.0017 0.0033 0.0049 0.0065 0.0080 0.0095 0.0109 0.0123 0.0137 0.0151 0.0183 0.0221 0.0261 9.00 0.0014 0.0029 0.0043 0.0057 0.0070 0.0083 0.0095 0.0107 0.0119 0.0132 0.0160 0.0193 0.0227 9.50 0.0013 0.0025 0.0038 0.0050 0.0062 0.0073 0.0083 0.0094 0.0104 0.0115 0.0140 0.0167 0.0197 10.00 0.0011 0.0022 0.0033 0.0044 0.0054 0.0064 0.0073 0.0082 0.0091 0.0101 0.0122 0.0145 0.0171

Caic Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 43 of 3 49 Date: 08/27/03 Table 6-7b. Soil Spectra for M=6.0, Set 2, Lower Vs Soil Profile Per (see) 0.1R

0.

0.3 g 0.4g 0.5,,

0.6g 0.,-

U 0.9R 1.0 1.2g 1.4,p 1.6g1 0.01 0.1507 0.2801 0.3742 0.4518 0.5126 0.5546 0.5804 0.5931 0.6041 0.6436 0.7135 0.7558 0.7833 0.03 0.1564 0.2874 0.3-822 0.4595 0.5205 0.5622 0.5879 0.6005 0.6074 0.6493 0.7184 0.7599 0.7869 0.04 0.1636 0.2950 0.3897 0.4671 0.5283 0.5703 0.5955 0.6077 0.6142 0.6540 0.7228 0.7637 0.7902 0.05 0.1699

-0.2927 0.3746 0.4531 0.5175 0.5654

  • 0.5947 0.6093 0.6181 0.6604 01W 0.7685 0.7946 0.06 0.1834 0.3013 10.3678 0.4532 0.5206 0.5696 0.5991 0.6151 0.6236 0.6665 0.7367 0.7748 0.8001 0.07 0.1833 0.3103 0.3855 0.4546 0.5215 0.5710 0.6022 0.6180 0.6412 0.6839 0.7523 0.7864 0.8077 0.08 0.2520 0.4015 0.4902 0.5645 0.6192 0.6501 0.6676 0.6734 0.6731 0.6928 0.7648 0.8000 0.8210 0.09 0.2849 0.4627 0.5677 0.6520 0.7119 0.7485 0.7642 0.7624 0.7593 0.7475 0.784-2 0.8154 0.8347 0.10 0.2983 0.4815 0.5922 0.6729 0.7357 0.7781 0.7995 0.8053 0.8010 0.7940 0.7949 0.8330 0.8524 0.11 0.3046 0.4597 0.5549 0.6359 0.7025 0.7596 0.8129 0.8594 0.8898 0.9118 0.9186 0.8578 0.8598 0.12 0.3363 0.5126 0.62-28 0.7116 0.7901 0.8603 0.9185 0.9708 1.0073 1.0320 1.0390 0.9684 0.8876 0.13 0.3634 0.5559 0.6671 0.7648 0.8675 0.9402 0.9923 1.0502 1.0904 1.1217 1.1311 1.0531 0.9647 0.14 0.4425 0.6727 0.7946 0.9437 1.0804 1.1737 1.2169.1.2245 1.2086 1.1935 1.2010 1.1171 1.0224 0.15 0.4121 0.7334 0.9316 1.0368 1.1623 1.2568 1.3094 1.3153 1.2841 1.2395 1.1108 1.0224 0.9574 0.16 0.4377.

0.8010 1.0516 1.2107 1.2S58 1.3035 1 2955 1.2686 1.2437 1.2016 1.1418 1.1397 1.1012 0.17 6.5li3 0.~8353 1.0781 1:2791 1.3913 1.4298 1.4:243 1.4408 1.4450 1.4582 1:4841 1.4400 1.365k 0.18 0.4712 0.8169 1.1214 1.3599-1.5031 1.5606 1.5646 1.5410 1.5007 1.4562 1.3834 1.2-764 1.2165 0.19 0.4648 0.7746 1.0824 1.3409 1.5073 1.5828 1.6024 1.5881 1.5569 1.5868 1.6113 1.5411 1.4732 0.20 0.5290 0.8502 1.0815 1.3081 1.4913 1.6039 1.6689 1.7214 1.7658 1.8059 1.8234 1.7471 1.6713 0.21 0.4751 0.7892 1.0306 1.2402 1.3948 1.4890 1.5601 1.6152 1.6786 1.7221 1.7564 1.6942 1.6363 0.22 0.4636 0.7976 1.0567 1.2640 1.4123 1.5084 1.5847 1.6555 1.7281 1.7821 1.8174 1.7618 1.7096 0.23 0.4571 0.7982 1.0709 1.2740 1.4126 1.5091 1.5909 1.6741 1.7535 1.8171 1.8608 1.8049 11.7661 0.24 0.4625 0.8048 1.0859 1.2912 1.4312 1.5297 1.6297 1.7260 1.8213 1.8865 1.9366 1.8861 11.8564 0.25 0.4848 0.7915 1.1028 1.3303 1.4875 1.6040 1.7183 I1.8216 1.9296 2.0243 2.0873 1.9929 1.9725 0.26 0.5329 0.8760 1.0868 1.2813 1.4505 1.6014 1.7366 1.8959 2.0499 2.1638 2.2569 2.1530 2.0432 0.27 0.5721 1.0184 11.2713 1.4603 1.5853 1.6856 1.8046 1.9138 2.0191 2.0961 2.1684 2.1172 2.1297 0.28 0.5658 1.0217 1.3027 1.5254 1.6863 I.7936 1.8689 1.9717 2.0759 2.1485 2.2089 2.1409 2.1343 0.29 0.5171 0.9857 1.3597 1.6301 1.7894 1.8564 1.8647 1.9314 2.0259 2.0958 2.1424 2.0695 2.0535 0.30 0.4778 1.0157 1.4294 1.7469 1.9525 2.0625 2.1022 2.0924 2.0767 2.0495 2.0779 2.0016 1.9799 0.31 0.4759 1.0064 1.4387 1.7840 2.0258 2.1680 2.2378 2.2514 2.2481 2.2264 2.1757 2.0784 2.0503 0.32 0.4615 0.9750 1.4116 1.7765 2.0455 2.2163 2.3111 2.3470 2.3574 2.3417 12.2806 2.1682 2.1253 0.33 0.4400 0.9318 1.3708 1.7474 2.0355 2.2340 2.3526 2.4076 2.4308 2.4212 2.3566 2.2273 2.1700 0.34 0.4159 0.8877 1.3230 1.7076 2.0152 2.2325 2.3732 2.4467 2.4817 2.4783 12.4112 2.2662 2.1932 0.35 0.3935 0.8450 11.2765 1.6669 1.9863 2.2205 2.3796 2.4696 2.5154 2.5175 12.5155 2.3118 2.2011 0.36 0.3713 0.8004 11.2243 1.6147 1.9413 2.1909 2.3619 2.4652 2.5193 2.5260 2.4608 2.3055 2.1827 0.37 0.3476 0.7508 11.1618 1.5465 1.8759 2.1326 2.3119 2.4239 2.4829 2.4964 2.5748 2.4317 2.2663 0.38 0.3258 0.6878 11.0762 1.4456 1.7671 2.0219 2.2038 2.3250 2.4938 2.6134 2.7164 2.5745 2.4014 0.39 0.3118 0.6445 10.9545 1.2884 1.5872 1.8252 2.0340 2.2726 2.4726 2.6111 2.6977 2.5674 2.4069 0.40 0.2850 0.6032 10.9150 1.2198 1.5020 1.7649 2.0149 2.2668 2.4905 2.6531 2.7853 2.6494 2.4964 0.41 0.2712 0.5807 10.8978 1.2106 1.5089 1.7920 2.0592 2.3036 2.5158 2.6904 2.8700 2.7655 2.6057 0.42 0.2535 0.5344 10.8376 1.1387 1.4280 1.7047 1.9632 2.1965 2.4029 2.5634 2.7792 2.7232 2.5908 0.43 0.2422 0.4792 0.7581 1.0366 1.3070 11.5647 1.8062 2.03 10 2.2333 2.4007 2.6265 2.6126 2.5063 0.44 0.2353 0.4636 10.6879 0.9489 1.2047 1.4519 1.6894 1.9157 2.1255 2.3061 2.5377 2.5259 2.5271 0.45 0.2344 0.4460 10.6553 0.8-733 1.0910 11.3 174 1.5433 11.7651 1.9750 2.1557 2.3925 2.4918 2.6317 0.46 0.2364 0.4522 10.6573 0.8574 1.0483 1.2348 1.4215 1.6120 1.8088 1.9948 2.3166 2.5413 2.6832 0.47 0.2336 0.4493 10.6548 0.8556 1.0470 1.2354 1.4227 1.6141 1.8111 1.9962 2.3149 2.5374 2.6802 0.48 0.2273 0.4400 10.6426 0.8402 1.0296 1.2155 1.3999 1.5893 1.7821 1.9627 2.2732 2.4917 2.6343 0.49 0.2196 0.4270 10.6248 0.8181 1.0029 1.1839 1.3646 1.5479 1.7340 1.9090 2.2101 2.4233 2.5654 0.50 0.'2120 0.4141 10.6069 0.7944 0.9745 1.1504 1.3250 1.5028 1.6829 1.8508 2.1400 2.3493 2.4935 0.51 0.2058 0.4032 10.5914 0.7743 0.9492 1.1205 1.2898 1.4617 1.6360 1.7982 2.0783 2.2851 2.4335 0.52 0.2012 0.3950 10.5795 0.7586 10.9294 1.0966 1.2619 1.4288 1.5983 1.7561 2.0301 2.2376 2.3911 0.53 0.1980 0.3890 10.5706 0.7467 0.9143 1.0782 1.2403 1.4036 1.5695 1.7242 1.9948 2.2053 2.3651 0.54 0.1953 0.3840 10.5630 0.7366 0.9017 1.0627 1.2224 1.3833 1.5462 1.6988 1.9680 2.1829 2.3493 0.55 0.1925 0.3788 0.5554 0.7265

.0.8894 1.0478 1.2053 1.3642 1.5246 1.6757 1.9444 2.1642 2.3367 0.56 0.1893 0.3727 0.5467 0.7153 0.8759 1.0322 1.1872 1'.3 442 1.5028 1.6519 1.9203 2.1445 2.32-23 0.57 0.1856 0.3658 0.5371 0.7027 0.8610 1.0152 1.1676 1.3227 1.4794 1.6267 1.8941 2.1218 2.3038 0.58 0.1816 0.3582 0.5266 0.6896 0.8453 0.9973 J1.1475 1.3001 1.4548 1.6005 1.8660 2.0964 2.2816 0.60 0.1732 0.3441 0.5130 0.6643 0.8155 0.9631 j1.1093 1.2570 1.4072 1.5495 1.8104 2.0442 2.2352 0.62 0.1682 0.3628 0.5480 0.7006 0.8145 0.9361 11.0786 1.2228 1.3685 1.5072 1.7649 2.0007 2.1972 0.64 0.1604 0.338 0.5205 0.6769 0.8085 0.9-231 j1.0546 1.:19:50 1.3~376 11.4729 1.7272 1.9664 2.67 0.66 0.1552 0.3141 0.4843 0.6526 0.8131 0.9610 1.0945 1.2142 1.3204 11.4368 1.6875 1.28 216

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Numbier: 44 of 349 Date: 08/27/03 0.68 0.1495 0.3103 0.4819 0.6532 0.8183 0.9724 1.1143 1.2444 i 1.3627 1 1.4593 l 1.6360 1.8782 2.0 88 J 0.70 0.1428 0.2941 0.4616 0.629 0.79370.94891.09411.23031.35611.46211.63031.809312.0207 0.72 0.1353 0.2728 0.4260 0.5862-0.'7442 0.8963 1.0409 1.17.90 1.3092.

1.4219 J1.6072 1.7654 1.9346 0.74 0.1279 0.2576 0.3914 0.5387 0.6840 0.8248 0.9662 1.1036 I1.2350 1.3525 *j1.5524 1.7278

-1.88410 0.76 0.1216 0.2462 0.3858 0.5310 0.6750 0.8126 0.9438 1.0669 1.1811 1.2829 1.4840 1.6800 1.8478 0.78 0.1158 0.2402 0.3753 0.5164 0.6568 0.7920 0.9218 1.0447 1.1597 1.2629 1.4405 1.6431 1.8288 0.80 0.1102 0.2311 0.3607 0.4965 0.6323 0.7636 }f -0.8907 1.0119 1.1265 1.2302 14095 1.6278 1.8264 0.82 0.1045 0.2200 0.3433 0.4728 0.6030 0.7297 0.8533 0.9723 1.0856 1.1891 1.3794 1.6190 1.8245 0.84 0.0989 0.2071 0.3233 0.4461 0.5701 0.6915 0.8106 0.9263 1.0373 1.1394 1.3626 1.6011 1.8095 0.86 0.0942 0.1929 0.3014 0.4166 0.5335 0.6486 0.7624 0.8739 0.9818 1.0900 1.3316 1.5666 1.7756 0.88 0.0936 0.1833 0.2774 0.3842 0.4932 0.6013 0.7090 0.8160 0.9329 1.0511 1.2842 1.5130 1.7200 0.90 0.0971 0.1903 0.2762 0.3584 0.4570 0.5596 0.6661 0.7749 0.8861 0.9986 1.2212 1.4418 1.6443 0.92 0.0976 0.1939 0.2841 0.3714 0.4529 0.5320 0.6215 0.7243 0.8292 0.9355 1.1462 1.3722 1.6065 0.94 0.0977 0.1955 0.2877 0.3771 0.4609 0.5415 0.6248 0.7134 0.8088 0.9127 1.1348 1.3657 1.5959 0.96 0.0984 0.1964 0.2892 0.3792 0.4632 0.5436 0.6256 0.7116 0.8035 0.9031 1.1176 1.3428 1.5671 0.98 0.0980 0.1948 0.2874 0.3770 0.4604 0.5397 0.6195 0.7022 0.7898 0.8843 1.0891 1.3069 1.5235 1.00 0.0964 0.1912 0.2822 03707 0.4528 0.5304 0.6077 0.6868 0.7696 0.8586 1.0527 1.2614 1.4694 1.05 0.0903 0.1776 0.2624 0.3458 0.4234 0.4958 0.5667 0.6375 0.7097 0.7854 0.9517 1.1357 1.3206 1.10 0.0854-1 0.1665 1 0.2456 1 0.3241' 0.3976 1 -0.466fi 1 0.5326 1 0.5981 I 0.6634 1 0.7302 1 T.t749 Cf:'1j0380 1.2049-1.15 0.0847 0.1643 0.2361 0.3093 0.3801 0.4463 0.5103 0.5729 0.6347 0.6963 0.8267 0.9746 1.1292 1.20 0.0892 0.1730 0.2519 0.3275 0.3956 0.4570 0.5152 0.5712 0.6258 0.6787 0.7800 0.9140 L.0576 1.25 0.0964 0.1866 0.2696 0.3503 0.4250 0.4937 0.5586 0.6200 0.6786 0.7349 0.8401 0.9371 1.0284 1.30 0.0960 0.1870 0.2710 0.3524 0.4282 0.4988 0.5664 0.6307 0.6921 0.7507 0.8603 0.9613 1.0561 1.35 0.08S6 0.1738 0.2532 0.3305 0.4029 0.4710 0.5369 0.6003 0.6612 0.7193 0.8283 0.9290 1.0232 1.40 0.0810 0.1623 0.2392 0.3132 0.3794 0.4369 0.4887 0.5476 0.6058 0.6617 0.7666 0.8636 0.9540 1.45 0.0836 0.1659 0.2440 0.3196 0.3876 0.4472 0.5016 0.5508 0.5952 0.6342 0.7033 0.7958 0.R812 1.50 0.0851 0.1692 0.2476 0.3226 0.3897 0.4486 0.5022 0.5500 0.5920 0.6283 0.6899 0.7469 0.8270 1.55 0.0838 0.1682 0.2476 0.3231 0.3919 0.4550 0.5123 0.5633 0.6081 0.6466 0.7086 0.7580 0.8075 1.60 0.0799 0.1612 0.2401 0.3183 0.3908 0.4561 0.5159 0.5698 0.6177 0.6592 0,7265 0.7796 0.8271 1.65 0.0768 0.1556 0.2336 0.3107 0.3830 0.4490 0.5099 0.5651 0.6144 0.6573 0.7268 0.7815 0.8287 1.70 0.0736 0.1499 0.2254 0.2999 0.3704 0.4350 0.4945 0.5483 0.5962 l 0.6377 07042 0.7559 0.8 173 1.75 0.0680 0.1394 0.2106 0.2808 0.3471 0.4079 0.4635 0.5133 0.5569 0.6046 0.6881 0.7519 0.8219 1.80 0.0594 0.1228 0.1866 0.2513 0.3175 0.3817 0.4436 0.5023 0.5572 0.6110 0.7083 0.7875 0.8556 1.85 0.0547 0.1145 0.1777 0.2426 0.3074 0.3704 0.4309 0.4881 0.5444 0.5988 0.6924 0.7682 0.8333 1.90 0.0514 0.1074 0.1665 0.2273 0.2880 0.3469 0.4033 0.4566 0.5063 0.5590 0.6611 0.7499 0.8279 1.95 0.0481 0.0974 0.1506 0.2053 0.2609 0.3187 0.3766 0.4340 0.4904 0.5457 0.6488 0.7392 0.8190 2.00 0.0451 0.0918 0.1419 0.1946 0.2492 0.3050 0.3610 0.4168 0.4721 0.5263 0.6281 0.71I81 0.7980 2.05 0.0421 0.0861 0.1341 0.1841 0.2360 0.2891 0.3427 0.3962 0.4493 0.5016 0.6001 0.6878 0.7661 2.10 0.0396 0.0808 0.1256 0.1727 0.2216 0.2717 0.3222 0.3728 0.4231 0.4726 0.5662 0.6501 0.7255 2.15 0.0373 0.0764 0.1168 0.1607 0.2063 0.2531 0.3002 0.3475 0.3944 0.4408 0.5285 0.6077 0.6793 2.20 0.0350 0.0720 0.1103 0.1492 0.1906 0.2338 0.2774 0.3212 0.3647 0.4076 0.4890 0.5632 0.6305 2.25 0.0328 0.0678 0.1041 0.1412 0.1.789 0.2172 0.2558 0.2949 0.3348 0.3744 0.4496 0.5196 0.5861 2.30 0.0307

-0.0637 0.0983 0.1336 0.1698 0.2067 0.2440 0.2816 0.3195 0.3573 0.4308 0.5091 0.5965 2.35 0.0293 0.0600 0.0929 0.1267 0.1616 0.1973 0.2333 0.2696 0.3061 0.3484 0.4418 0.5350 0.6269 2.40 0.0284 0.0587 0.0907 0.1240 0.1590 0.1957 0.2335 0.2725 0.3126 0.3539 0.4402 0.5344 0.6268 2.50 0.0269 0.0560 0.0870 0.1195 0.1538 0.1898 0.2270 0.2656 0.3055 0.3467 0.4310 0.5164 0.6019 2.60 0.0242 0.0492 0.0741 0.1000 0.1293 0.1604 0.1928 0.2265 0.2614 0.2976 0.3721 0.4508 0.5345 2.70 0.0227 0.0462 0.0697 0.0929 0.1167 0.1442 0.1741 0.2054 0.2382 0.2726 0.3447 0.4201 0.4988 2.80 0.0214 0.0436 0.0658 0.0879 0.1097 0.1324 0.1557 0.1809 0.2072 0.2358 0.2972 0.3642 0.4339 2.90 0.0201 0.0410 0.0622 0.0832 0.1041 0.1249 0.1458 0.1668 0.1891 0.2135 0.2657 0.3228 0.3842 3.00 0.0189

, 0.0386 0.0586 0.0787 0.0988 0.1189 0.1390 0.1591 0.1795 0.2001 0.2411 0.2886 0.3436 3.10 0.0176 0.0361 0.0551 0.0743 0.0936 0.1130 0.1323 0.1517 0.1712 0.1909 0.2304 0.2694 0.3078 3.20 0.0164 0.0337 0.0517 0.0700 0.0885 0.1071 0.1256 0.1442 0.1628 0.1817 0.2195 0.2569 0.2939 3.30 0.0153 0.0314 0.0483 0.0657 0.0834 0.1011 O.188 0.1365 0.1543 0.1723 0.2084 0.2441 0.2796 3.40 0.0143 0.0294 0.0452 0.0615 0.0782 0.0950 0.1119 0.1287 0.1456 0.1627 0.1970 0.2311 0.2648 3.50 0.0134 0.0274 0.0421 0.0574 0.0732 0.0890 0.1050 0.1209 0.1370 0.1531 0.1856 0.2178 0.2499 3.60 0.0125 0.0255 0.0391 0.0534 0.0682 0.0831 0.0981 0.1132 0.1283 0.1436 0.1742 0.2046 0.2349 3.70 0.0116 0.0237 0.0363 0.0496 0.0633 0.0773 0.0914 0.1056 0.1198 0.1342 0.1630 0.1915 0.2200 3.80 0.0107 0.0220 0.0336 0.0459 0.0587 0.0717 0.0849 0.0982 0.1115 0.1249 0.1519 0.1787 0.2055 3.90 0.0099 0.0203 0.0311 0.0424 0.0542 0.0664 0.0787 0.0910 0.1035 0.1160 0.1412 0.1663 0.1913 4.00 0.0091 0.0187

.287 0.0391 0.0500 0.0613 0.0727 0.0842 0.0958 0.1074 0.1309 0.1542 0.1776 4.10 0.0084 0.0172 0.0264 0.0360 0.0460 0.0564 0.0670 0.0777 0.0884 0.0993 0.1211 0.1428 0.1646 4.20 0.0077 0.0158 0.0242 0.0330 0.0423 0.0519 0.0617 0.0715 0.0815 0.0915 0.1117 0.1319 0.1522 4.30 0.0070 0.0144 0.0222 0.0303 0.0388 0.0476 0.0566 0.0657 0.0749 0.0842 0.1029 0.1216 0.1405 4.40 0.0066 0.0133 0.0204 0.0277 0.0355 0.0436 1 0.0519 0.0603 0.0688 0.0774 0.0946 0.1120 0.1295

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 45 of 349 Date: 08/27/03 4.50 0.0063 0.0129 0.0197 0.0266 0.0334 0.0402 0.0476 0.0553 1 0.0631 0.0710 0.0869 3 0.1029 0.1196 4.60

--.0.0061 0.0125 0.0190 0.0257 0.0323 0.0389 0.0454 0.0519 1 0.0584 0.0651 0.0797 I 0.0946 0.1106 4.70 0.0059 0.0120 0.0174 0.0249 0.0312 0.0376 0.0439 0.0402 0.05 0.0628 0.0755 0.08 54 0.1091 4.70 0.0057 0.0116 0.0177 0.0239 0.0301 0.0363 0.0425 0.0486 0.0547 0.0608 0.0731 0.0846 0.0982 4.90 0.0055 0.0112 0.0171 0.0231 0.0291 0.0351 0.0410 0.0469 0.0528 0.0587 0.0707 0.0828 0.095 1 5.00 0.0053 0.0108 0.0165 0.0223 0.0281 0.0338 0.0396 0.0453 0.0510 0.0568 0.0683 0.0801 0.0919 5.10 0.0051

-0.0104

.t1059 0.0215

.0.0271 0.0327 0.0382 0.0437 0.0493

.0 0548*

0.0660-0.07741.

0.0389.

5.20 0.0049 0.0100 0.0153 0.0207 0.0261 0.0315 0.0369 0.0422 0.0476 0.0529 0.0638 0.0748 0.0S59 5.40 0.0046 0.0093 0.0142 0.0192 0.0243 0.0293 0.0343 0.0393 0.0443 0.0493 0.0594 0.0697 0.0802 5.60 0.0043 0.0087 0.0132 0.0179 0.0226 0.0272 0.0319 0.0366 0.0413 0.0459 0.0554 0.0650 0.0748 5.80 0.0040 0.0080 0.0123 0.0166 0.0210 0.0253 0.0297 0.0341 0.0384 0.0428 0.0516 0.0607 0.0698 6.00 0.0037 0.0075 0.0114 0.0154 0.0195 0.0236 0.0277 0.0317 0.0358 0.0399 0.0481 0.0566 0.0651 6.20 0.0035 0.0070 0.0106 0.0144 0.0182 0.0220 0.0258 0.0296 0.0334 0.0372 0.0449 0.0528 0.0608 6.40 0.0033 0.0065 0.0099 0.0134 0.0169 0.0205 0.0240 0.0276 0.0312 0.0347 0.0420 0.0493 0.0568 6.60 0.0031 0.0061 0.0092 0.0125 0.0158 0.0191 0.0224 0.0258 0.0291 0.0325 0.0392 0.0461 0.0531 6.80 0.0029 0.0057 0.0086 0.0117 0.0148 0.0179 0.0210 0.0241 0.0272 0,0304 0.0367 0.0432 0.0497 7.00 0.0027 0.0054 0.0081 0.0109 0.0138 0.0167 0.0196 0.0226 0.0255 0.0285 0.0344 0.0405 0.0466 7.20 0.0025 0.0050 0.0076 0.0102 0.0129 0.0157 0.0184 0.0212 0.0239 0.0267 0.0322 0.0379 0.0437 7.40

0.0024 0.0047 0:0071 0.0096 0.0121 0.0147 0.0173--

C0199 0.0225 0.0251 0.0303 0.0356 0.0411 7.60 0.0022 0.0045 0.0067 0.0090 0.0114 0.0138 0.0162 0.0187 0.0211 0.0236 0.0285 0.0335 0.0386 7.80 0.0021 0.0042 0.0063 0.0085 0.0107 0.0130 0.0153 0.0176 0.0199 0.0222 0.0268 0.0315 0.0363 8.00 0.0020 0.0040 0.0060 0.0080 0.0101 0.0123 0.0144 0.0166 0.0187 0.0209 0.0253 0.0297 0.0343 8.50 0.0017 0.0034 0.0052 0.0069 0.0088 0.0106 0.0125 0.0144 0.0162 0.0181 0.0219 0.0258 0.0297 9.00 0.0015 0.0030 0.0045 0.0061 0.0077 0.0093 0.0109 0.0125 0.0142 0.0158 0.0191 0.0225 0.0259 9.50 0.0013 0.0026 1 0.0040 0.0053 0.0067 0.0081 0.0096 0.0110 0.0125 0.0139 0.016S 0.0197 0.0228 10.00 0.0012 0.0023 1 0.0035 0.0047 0.0059 0.0072 0.0085 0.0098 0.0110 0.0123 0.014S 0.0175 0.0201

Calc Number: GEO.HBEP.03.02 Rev Number: 0 Sheet Number: 46 of 349 Date: 08/27/03 Table 6-7c. Soil Spectra for M6.0, Set 3, Lower Vs Soil Profile Per (sec)

0. Is 0.2g 0.3_g 0.4g 0.5g 0.6g 0.7g 0.8g 0.9 g

_ 1.0

1.

1.4 1.6c 0.01 0.1529 0.2655 0.3640 0.4379 0.4818 0.5166 0.5480 0.5756 0.6017 0.6283 0.6581 I 0.6739 0.7102 0.03 0.1603 0.2756 0.3679 0.4426 0.4869 0.5221 0.5535 0.5814 0.6077 0.6346 0.6641 0.6785 0.7144 0.04 0.1710 0.2897 0.3718 0.4470 0.4917 0.5270 0.5586 0.5867 0.6131 j 0.6405 0.6698 1 0.6827

- 0.7184 0.05

.021773 0.3D40 0.3751 M 0.4519 1 0.4968 I -0.5328-0.5640 0.5932 f 0.6199 I 0.6480 I-0.6771 0.6879 L 0.7236 1 0.06 0.2076 0.3425 0.4086 0.4578 0.5033 0.5400 0.5718 0.6086 0.6427 0.6694 0.6857 0.6952 0.7302 0.07 0.2275 0.3760 0.4521 0.5031 0.5267 0.5645 0.6029 0.6443 0.6770 0.6986 0.7101 0.7043 0.7383 0.08 0.2451 0.4021 0.4899 0.5412 0.5695 0.6019 0.6444 0.6808 0.7139 0.7363 0.7434 0.7249 0.7456 0.09 0.2646 0.4459 0.5409 0.5990 0.6242 0.6554 0.6952 0.7321 0.7637.

0.7824 0.7859 0.7599 0.7577 0.10 0.2859 0.4817 0.5864 0.6567 0.6804 0.7108 0.7475 0.7856 0.8146 0.8354 0.8350 0.8027 0.7876 0.11 0.3077 0.5184 0.6430 0.7171 0.7404 0.7679 0.8047 0.8409 0.8700 0.8913 0.8879 0.8491 0.8173 0.12 0.3212 0.5544 0.6964 0.7737 0.7985 0.8229 0.8601 0.8925 0.9244 0.9452 0.9410 0.8955 0.8591 0.13 0.3406 0.6008 0.7604 0.8525 0.8726 0.8964 0.9232 0.9576 0.9835 1.0064 0.9942 0.9424 0.9030 0.14 0.3435 0.6159 0.7856 0.8806 0.9321 1.0142 1.0705 1.0828 1.0488 1.0225 1.0287 0.9638 0.9233 0.15 0.4167 0.6867 0.8339 0.9275 0.9961 1.0947 1.2066 1.2730 1.2999 1.3093 1.2615 1.1905 1.0824 0.16 0.4896 0.7542 0.9294 1.,724 1.1642 1.2400 1.3052 1.3446 1.3811 1.4088 1.3899 1.2782 1.1655 0.17 0.4719 0.7889 0.9604-1;0855 1.2125 1.3537 1.4693 1.5311 ' 1.5476 1.5441 1.5035 1.4403 M3-233 0.18 0.4575 0.S398 1.0646 1.2106 1.3186 1.4499 1.5611 1.6366 1.6685 1.6780 1.6511 1.5878 1.4818 0.19 0.5299 0.8307 1.0717 1.3201 1.5154 1.6367 1.6871 1.6777 1.6437 1.6083 1.5315 1'4761 1.4030 0.20 0.5191 0.8445 1.0602 1.2399 1.429S 1.5602 1.6332 1.7034 1.7538 1.7796 1.7854 1.7518 1.6484 0.21 0.4517 0.8105 1.1236 1.2982 1.4259 1.5498 1.6350 1.6836 1.6985 1.7350 1.7411 1.6968 1.6143 0.22 0.4353 0.7973 1.1281 1.3458 1.4812 1.5861 1.6574 1.6960 1.7161 1.7342 1.7192 1.6455 1.5832 0.23 0.4760 0.8174 1.0796 1.3242 1.5198 1.6534 1.7219 1.7421 1.7538 1.7699 1.8202 1.8334 1.7833 0.24 0.4706 0.8359 1.1141 1.3560 1.5320 1.6512 1.7203 1.7443 1.7643 1.7850 1.8329 1.8429 1.7988 0.25 0.4743 0.8511 1.1343 1.3700 1.5388 1.6594 1.7320 1.7692 1.7952 1.8181 1.8652 1.8788 1.8406 0.26 0.4959 0.8576 1.1472 1.3852 1.5526 1.6724 1.7478 1.7867 1.8097 1.8325 1.9273 1.9545 1.9266 0.27 0.4906 0.8836 1.1777 1.4172 1.5835 1.7031 1.7836 1.8255 1.8538 1.8994 2.1012 2.2078 2.1775 0.28 0.4664 0.8642 1.1639 1.4012 1.5641 1.6833 1.7634 1.8090 1.8564 1.9075 2.0553 2.1921 2.1948 0.29 0.4725 0._887 1.2548 1.5049 1.6441 1.7510 1.8575 1.9556 2.0470 2.1148 2.1774 2.1925 2.1716 0.30 0.4402 0.8486 1.1918 1.4266 1.5631 1.6768 1.7789 1.8901 1.9960 2.0813 2.1652 2.1731 2.1366 0.31 0.4056 0.7878 1.1060 1.3365 1.5194 1.6532 1.7340 1.8429 1.9501 2.0338 2.1126 2.1075 2.0679 0.32 0.4013 0.7766 1.1037 1.3544 1.5260 1.6695 1.7909 1.9009 2.0036 2.0829 2.1618 2.1571 2.1403 0.33 0.3909 0.7662 1.0986 1.3539 1.5276 1.6697 1.7903 1.8912 1.9905 2.0774 2.1664 2.1808 2.1810 0.34 0.3792 0.7594 1.1019 1.3621 1.5335 1.6700 1.7840 1.8846 1.9865 2.0754 2.1708 2.2086 2.2140 0.35 0.3872 0.7882 1.1496 1.4230 1.5954 1.7264 1.8318 1.9377 2.0451 2.1591 2.3394 2.4318 2.4519 0.36 0.3877 0.7980 1.1650 1.4326 1.5911 1.8194 2.0248 2.2019 2.3823 2.5387 2.7446 2.8434 2.8646 0.37 0.3340 0.6870 1.1008 1.4750 1.7611 2.0120 2.2385 2.4374 2.6271 2.7851 2.9679 3.0187 3.0478 0.38 0.3169 0.6401 1.0219 1.3795 1.7147 2.0103 2.2809 2.5257 2.7473 2.9302 3.1447 3.2153 3.1774 0.39 0.2901 0.5742 0.9211 1.2944 1.6163 1.9096 2.1838 2.4359 2.6718 2.8641 3.1007 3.1939 3.1897 0.40 0.2760 0.5401 0.8703 1.2265 1.5427 1.8398 2.1238 2.3886 2.6326 2.8356 3.0919 3.2118 3.2338 0.41 0.2690 0.5273 0.8189 1.1596 1.4720 1.7691 2.0550 2.3219 2.5671 2.7737 3.0464 3.1902 3.2363 0.42 0.2553 0.5006 0.7554 1.0467 1.3390 1.6192 1.8S79 2.1407 2.3751 2.5770 2.8579 3.0212 3.0888 0.43 0.2488 0.4909 0.7131 0.9375 1.1931 1.4519 1.7034 1.9919 2.3004 2.5653 2.8886 3.0391 3.1152 0.44 0.2429 0.4704 0.6751 0.8893 1.0947 1.3331 1.5918 1.8691 2.1574 2.4030 2.7102 2.8530 2.9206 0.45 0.2452 0.4758 0.6775 0.8831 1.0660 1.2399 1.4123 1.6382 1.8752 2.0910 2.4217 2.6402 2.7711 0.46 0.2394 0.4677 0.6699 0.8562 1.0394 1.2152 1.3905 1.5656 1.7501 1.9236 2.1997 2.4100 2.6078 0.47 0.2281 0.4469 0.6424 0.8153 0.9810 1.1504 1.3195 1.4889 1.6669 1.8331 2.0929 2.2896 2.4795 0.48 0.2206 0.4305 0.6181 0.7836 0.9252 1.0858 1.2469 1.4074 1.5759 1.7334 1.9772 2.1649 2.3553 0.49 0.2202 0.4269 0.6114 0.7742 0.9043 1.0467 1.2029 1.3605 1.5271 1.6828 1.9249 2.1169

_2.3239 0.50 0.2220 0.4232 0.6074 0.7703 0.9017 1.0282 1.1625 1.3209 1.4905 1.6503 1.9025 2.1096 2.3393 0.51 0.2369 0.4434 0.6256 0.7882 0.9218 1.0433 1.1549 1.2594 1.3999 1.5615 1.8198 2.0350 2.2772 0.52 0.2402 0.4508 0.6381 0.8082 0.9485 1.0754 1.1930 1.3037 1.4198 1.5242 1.6837 1.8411 2.0772 0.53 0.2290 0.4343 0.6189 0.7854 0.9261 1.0525 1.1697 1.2795 1.3961 1.5014 1.6488 1.7775 1.9667 0.54 0.2165 0.4156 0.5958 0.7558 0.8937 1.0170 1.1290 1.2338 1.3439 1.4450 1.5850 1.6886 1.8687 0.55 0.2094 0.4056 0.5832 0.7409 0.8765 0.9965 1.1040 1.2028 1.3072 1.4020 1.5331 1.6275 1.7844 0.56 0.2070 0.4037 0.5810 0.7404 0.8751 0.9925 1.0967 1.1902 1.2899 1.3795 1.5035 1.5919 1.7294 0.57 0.2090 0.4082 0.5860 0.7503 0.8851 1.0013 1.1030 1.1938 1.2890 1.3766 1.4948 1.5795 1.7164 0.58 0.2099 0.4086 0.5849 0.7525 0.8872 1.0025 1.1028 1.1907 1.2836 1.3683 1.4829 1.5661 1.7054 0.60 0.1942 0.3776 0.5455 0.7087 0.8427 0.9560 1.0502 1.1299 1.2127 1.2879 1.3873 1.4625 1.5982 0.62 0.1858 0.3767 0.5576 0.7212 0.8604 0.9727 1.0609 1.1294 1.1993 1.2615 1.3380 1.3982 1.5279 0.64 0.1838 0.3S02 0.5767 0.7571 0.9013 1.0113 1.0858 1.1263 1.1732 1.2138.

1.2632 1.3071 1.4349 0.66 0.1741 0.3594 0.5573 0.7432 l

0.8974 1.0190 1.1040 1.1533 1.1846 1.2147 1.1943 1.2079 1 1.2874

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 47 of 349 Date: 08/27/03 0.68 I 0.1589 0.3307 0.5079 0.6875 0.8394 0.9589 1.0500 1.1442 1 1.2205 1.2633 1.2979 1.2696 1.2808 0.70 0.1401 0.2945 0.4551 0.6099 0.7728 0.9233 1.0514 1.1629 ] 1.2713 1.3498 1.4032 1.3520 1.3434 0.72 0.1185 0.2527 0.3988 0.5512 0.7127 0.8710 1.0202 1.1526 1.2657 1.3493 1.4118 1.3689 1.3680 0.74 0.1130 0.2365 0.3718 0.5167 0.6625 0.8107 0.9511 1.0769 1.1856 1.2662 1.3296 1.2960 1.3686 0.76 0.1071 0.2186 0.3334 0.4622 0.5910 0.7155 0.8297 0.9273' 1.0283 1.1592 1.3654 1.4617 1.5384 0.78 0.1158 0.2359 0.3598 0-0.4844 0.6025 0.7213 0.8461 0.9806 1.1221 1.2582 1.4695 1.5655 1.6469 0.80 0.1190

.0.2413 0.3681 0.49731.. -0.6211 0.7448.

0.8730 1.0086 1.1498 1.2850

.1.4947

,_1.5917 1 1.6778 0.82 0.1171 0.2364 0.3604 0.4875 0.6105 0.7332 0.8590 0.9905 1.1266 1.2569 1.4607 1.5600 1.6510 0.84 0.1118 0.2253 0.3430 0.4645 0.5829 0.7009 0.8215 0.9468 1.0759 1.1997 1.3969 1.5018 1.5978 0.86 0.1052 0.2119 0.3223 0.4365 0.5488 0.6612 0.7759 0.8949 1.0172 1.1350 1.3286 1.4424 1.5433 0.88 0.0995 0.1997 0.3029 0.4100 0.5163 0.6233 0.7328 0.8466 0.9634 1.0766 1.2694 1.3920 1.4953 0.90 0.1039 0.1980 0.2940 0.3944 0.4946 0.5961 0.7006 0.8098 0.9213 1.0305 1.2208 1.3467 1.4497 0.92 0.1068 0.2045 0.2924 0.3866 0.4829 0.5798 0.6791 0.7827 0.8886 0.9927 1.1771 1.3021 1.4034 0.94 0.1081 0.2078 0.2984 0.3845 0.4716 0.5650 0.6602 0.7589 0.8599 0.9591 1.1364 1.2588 1.3610 0.96 0.1083 0.2087 0.3008 0.3882 0.4672 0.5510 0.6427 0.7374 0.8341 0.9294 1.1001 1.2238 1.3374 0.98 0.1076 0.2080 0.3006 0.3887 0.4677 0.5454 0.6268 0.7183 0.8115 0.9032 1.0683 1.2008 1.3127 1.00 0.1063 0.2060 0.2984 0.3864 0.4652 0.5420 0.6201 0.7021 0.7905 0.8795 1.0465 1.1763 1.2864 1.05 0.1007 0.1958 0.2851 0.3704 0.4463 0.5197 0.5932 0.6694 0.7492 0.8300 0.9818 1.0990 1.2020

.!t-I :f-Hv0 0.0949 1 0.1848 { 0.2694 I. 0.350

1 0.4227 0.4920.1 0.5607 I 0.6316 1
17054ti1V0.7797 0.9169 4A0227
1. I1187 IP.-.

1.15 0.0921 0.1791 0.2612 0.3404 0.4106 0.4777 0.5442 0.6185 0.6948 0.7699 0.9072 1.0145 1.1092 1.20 0.0926 0.1774 0.2.564 0.3330 0.4011 0.4721 0.5466 0.6222 0.6989 0.7748 0.9148 1.0280 1.1303 1.25 0.0904 0.1734 0.2498 0.3232 0.3879 0.4552 0.5278 0.6018 0.6775 0.7527 0.8933 1.0109 1.1196 1.30 0.0854 0.1642 0.2338 0.3024 0.3668 0.4266 0.4867 0.5570 0.6294 0.7018 0.8392 0.9584 1.0699 1.35 0.0796 0.1545 0.2269 0.2980 0.3637 0.4254 0.4837 0.53S8 0.5912 0.6439 0.7762 0.8951 1.0063 1.40 0.0784 0.1505 0.2203 0.2899 03551 0.4171 0.4760 0.5322 0.5858 0.6365 0.7257 0.8406 0.9485 1.45 0.0743 0.1460 0.2149 0.2828 _0.3466 0.4076 0.4660 0.5218 0.5754 0.6260 0.7136 0.7993 0.9030 1.50 0.0720 0.1420 0.2092 0.2754 0.3373 0.3965 0.4534 0.50S1 0.5612 0.6113 0.6968 0.7682 0.8685 1.55 0.0693 0.1368 0.2017 0.2654 0.3248 0.3817 0.4366 0.4899 0.5418 0.5911 0.6745 0.7431 0.S407 1.60 0.0657 0.1300 0.1918 0.2524 0.3089 0.3631 0.4158 0.4672 0.5177 0.5657' 0.6467 0.7206 0.8159 1.65 0.0616 0.1221 0.1804 0.2376 0.2910 0.3425 0.3927 0.4420 0.4907 0.5371 0.6151 0.6994 0.7925 1.70 0-0573 0.1138 0.1686 0.2224 0.2729 0.3217 0.3694 0.4165 0.4630 0.5074 0.5829 0.6793 0.7699 1.75 0.0531 0.1058 0.1571 0.2078 0.2557 0.3020 0.3474 0.3921 0.4365 0.4789 0.5672 0.6606 0.7488 1.80 0.0491 0.0982 0.1464 0.1942 0.2397 0.2901 0.3487 0.4072 0.4647 0.5200 0.6187 0.6898 0.7395 1.85 0.0472 0.0939 0.1441 0.2010 0.2621 0.3249 0.3882 0.4513 0.5132 0.5726 0.6771 0.7507 0.8036 1.90 0.0468 0.0979 0.1540 0.2136 0.2772 0.3420 0.4073 0.4722 0.5360 0.5972 0.7040 0.7789 0.8341 1.95 0.0478 0.0997 0.1557 0.2150 0.2779 0.3420 0.4066 0.4711 0.5347 0.5961 0.7039 0.7819 0.8404 2.00 0.0463 0.0965 0.1502 0.2068 0.2666 0.3280 0.3903 0.4533 0.5159 0.5766 0.6863 0.7692 0.8297 2.05 0.0434 0.0906 0.1410 0.1938 0.2502 0.3086 0.3686 0.4295 0.4898 0.5488 0.6572 0.7405 0.8001 2.10 0.0409 0.0843 0.1313 0.1804 0.2328 0.2870 0.3428 0.3995 0.4558 0.5111 0.6138 0.7199 0.8080 2.15 0.0394 0.0795 0.1195 0.1621 0.2093 0.2581 0.3115 0.3682 0.4265 0.4856 0.6032 0.7200 0.8170 2.20 0.0378 0.0764 0.1151 0.1548 0.2016 0.2511 0.3031 0.3573 0.4132 0.4702 0.5872 0.7044 0.7981 2.25 0.0361 0.0731 0.1105 0.1491 0.1940 0.2415 0.2913 0.3429 0.3958 0.4498 0.5598 0.6649 0.7539 2.30 0.0343 0.0697 0.1057 0.1418 0.1821 0.2271 0.2743 0.3234 0.3736 0.4247 0.5299 0.6328 0.7238 2.35 0.0326 0.0663 0.1007 0.1354 0.1700 0.2114 0.2561 0.3030 0.3515 0.4011 0.5052 0.6115 0.7047 2.40 0.0309 0.0628 0.0956 0.1289 0.1621 0.2010 0.2448 0.2907 0.3378 0.3858 - 0.4860 0.5873 0.6758 2.50 0.0274 0.0558 0.0852 0.1152 0.1465 0.1835 0.2221 0.2620 0.3026 03437 0.4287 0.5156 0.5930 2.60 0.0246 0.0508 0.0782 0.1064 0.1361 0.1665 0.1975 0.2333 0.2698 0.3069 0.3826 0.4594 0.5316 2.70 0.0223 0.0462 0.0713 0.0972 0.1246 0.1528 0.1817 0.2112 0.2409 0.2706 0.3315 0.4010 0.4685 2.80 0.0199 0.0414 0.0641 0.0878 0.1131 0.1391 0.1658 0.1930 0.2204 0.2478 0.3023 0.3552 0.4114 2.90 0.0179 0.0372 0.0578 0.0793 0.1022 0.1257 0.1499 0.1747 0.1997 0.2247 0.2746 0.3229 0.3681 3.00 0.0163 0.0335 0.0520 0.0713 0.0918 0.1130 0.1348 0.1572 0.1799 0.2026 0.2481 0.2923 0.3337 3.10 0.0154 0.0309 0.0468 0.0638 0.0821 0.1011 0.1208 0.1410 0.1616 0.1823 0.2237 0.2641 0.3020 3.20 0.0145 0.0292 0.0441 0.0593 0.0749 0.0907 0.1082 0.1264 0.1451 0.1639 0.2015 0.2383 0.2732 3.30 0.0137 0.0276

-0.0416 0.0559 0.0706 0.0855 0.1007 0.1163 0.1322 0.1484 0.1814 0.2161 0.2580 3.40 0.0130 0.0261 0.0394 0.0529 0.0667 0.0808 0.0953 0.1101 0.1252 0.1406 0.1720 0.2034 0.2428 3.50 0.0123 0.0248 0.0374 0.0502 0.0633 0.0767 0.0905 0.1046 0.1190 0.1336 0.1637 0.1938 0.2276 3.60 0.0117 0.0236 0.0355 0.0477 0.0603 0.0731 0.0862 0.0997 0.1135 0.1275 0.1562 0.1850 0.2126 3.70 0.0112 0.0225 0.0339 0.0456 0.0575 0.0698 0.0824 0.0953 0.1085 0.1219 0.1493 0.1769 0.2033 3.80 0.0106 0.0214 0.0324 0.0435 0.0550 0.0668 0.0789 0.0912 0.1038 0.1166 0.1428 0.1692 0.1945 3.90 0.0102 0.0205 0.0310 0.0417 0.0527 0.0640 0.0755 0.0874 0.0995 0.1117 0.1367 0.1619 0.1861 4.00 0.0097 0.0196 0.0296 0.0399 0.0505 0.0613 0.0724 0.0837 0.0953 0.1070 0.1309 0.1549 0.1780 4.10 0.0092 0.0187 0.0283 0.03S2 0.0483 0.0587 0.0693 0.0802 0.0913 0.1024 0.1252 0.1482 0.1702 4.20 0.0088 0.0179 0.0271 0.0365 0.0462 0.0562 0.0663 0.0767 0.0873 0.0980 0.1197 0.1416 0.1627 4.30 0.0084 0.0171 0.0259 0.0349 0.0442 0.0537 0.0634 0.0733 0.0834 0.0936 0.1143 0.1352 0.1553 4.40 0.0080 0.0163 0.0248 0.0334 0.0423 0.0513 0.0606 0.0700 0.0796 0.0894 0.1091 0.1290 0.1482

Calc Number: GEO.HBIP.0, 02 Rev Number: 0 Sheet Number: 48 of 349 Date: 08/27/03 4.50

- 0.0077 0.0156 0.0237 0.0319 0.0404 0.0490 l 0.0578 0.066 [ 0.0759 0.0852 J 0.1040 0.1230 0.1413 4.60 0.0073 0.0149 0.0226 0.0304 0.0385 0.0467 0.0550 0.0636 0.0723 0.0811 0.0990 0.1172 0.1347 4.70 0.0070 0.0142 0.0215 0.0290 0.0367 0.0444 0.0524 0.0605 0.0688 0.0772 0.0942 j 0.1115 0.12S2 4.80 0.0066 0.0135 0.0205 0.0276 0.0349 0.0422 0.0498 0.0575 0.0654 0.0733 0.0896 0.1061 0.1220 4.90 0.0063 0.0128 0.0195 0.0262 0.0331 0.0401 0.0473 0.0546 0.0620 0.0696 0.0851 0.1009 0.1161 5.00 0.0060 0.0122 0.0185 0.0249 0.0314 0.0381 0.0448 0.0518 0.0588 0.0660 0.0808

.00959 0.1104

.5.10 0.0057 0.0116 I 0.0176.1 0.0236-0.0298 0.0361 0.0425 0.0490 I 0.0557 0.0626 I 0.0766 1 0.0911 0.1050 I..

s 1n A AA IC AnAII n

I An AI 7

I A nnA I AAQl I

A AlA)

A AAAI)

A AAfg I

A ns-Q An (&2 I A nn 7 'I AlAlQr(

A nQ0 L ______

V.U JO**

U.U I AU U.

LU C0 t

U U.UAO.J V.VU fl U.U USU VJ.WUflJ CJ.U~JAO U.

J

0.

M/

UUO UU 7 5.40 0.0049 0.0099 0.0150 0.0201 0.0253 0.0306 0.0361 0.0416 0.0474 0.0532 0.0654 0.0780 0.0902 5.60 0.0044 0.0089 0.0135 0.0181 0.0227 0.0275 0.0323 0.0373 0.0425 0.0477 0.0588 0.0704 0.0815 5.80 0.0040 0.0080 0.0121 0.0162 0.0204 0.0246 0.0290 0.0335 0.0381 0.0429 0.0530 0.0636 0.0737 6.00 0.0036 0.0072 0.0109 0.0146 0.0183 0.0221 0.0261 0.0301 0.0343 0.0386 0.0478 0.0576 0.0668 6.20 0.0032 0.0065 0.0098 0.0132 0.0165 0.0199 0.0235 0.0272 0.0309 0.0349 0.0433 0.0522 0.0606 6.40 0.0030 0.0060 0.0089 0.0119 0.0149 0.0180 0.0212 0.0246 0.0280 0.0316 0.0393 0.0474 0.0551 6.60 0.0028 0.0056 0.0083 0.0111 0.0138 0.0166 0.0194 0.0223 0.0255 0.0287 0.0357 0.0432 0.0502 6.80 0.0025 0.0050 0.0074 0.0099 0.0124 0.0149 0.0176 0.0204 0.0232 0.0262 0.0326 0.0394 0.0458 7.00 0.0022 0.0044 0.0067 0.0090 0.0113 0.0136 0.0161 0.0186 0.0213 0.0240 0.0299 0.0361 0.0419 7.20 0.0020 0.0040 0.0061 0.0082 0.0103 0.0125 0.0148 0.0171 0.0196 0.0221 0.0275 0.0331 0.0384 7.40.

0.0018

.00037'i

-0.0056 0.0075

-.00095 0.0115

. 0.0136 0.01i 0.0181 0.0204 0.0253.. 0 0935 0.0353 7.60 0.0017 0.0034 0.0052 0.0070 0.0088 0.0107 0.0126 0.0146 0.0167 0.0189 0.0234 0.0281 0.0326 7.80 0.0016 0.0031 0.0048

  • 0.0065 0.0082 0.0099 0.0117 0.0136

.0.0155 0.0175 0.0217 0.0260 0.0301 8.00 0.0014 0.0029 0.0044 0.0060 0.0076 0.0092 0.0109 0.0127 0.0145 0.0163 0.0202 0.0242 0.0279 8.50 0.0012 0.0024 0.0037 0.0051 0.0064 0.0078 0.0093 0.0108 0.0123 0.0139 0.0170 0.0202 0.0233 9.00 0.0010 0.0021 0.0032 0.0043 0.0055 0.0068 0.0080 0.0093 0.0106 0.0119 0.0146 0.0172 0.0197 9.50 0.0009 0.0018 0.0028 0.0038 0.0048 0.0059 0.0070 0.0081 0.0093 0.0104 0.0126 0.0148 0.0169 10.00 0.0008 0.0016 0.0024 0.0033 0.0042 0.0052 0.0062 0.0071 0.0081 0.0091 0.0111 0.0129 0.0147 I

Calc Number: GEO.HBI3P.03-.02 Rev Number: 0 Sheet Number: 49 of 3 )49 Date: 03/27/03

~~Table 6-8a. Soil Spectra for M=7.0, Set 1, Lower Vs Soil Profile PerJ06

.g

.8 09 c 10

g.

(See) lit~

U 0.3p 0.4v 0.5pg 0

O.

L____

I.g

.4-0.01 0.1565 0.2969 0.4013 0.4807

-0.5544 0.6130 0.6431 j0.6489 0.6675 0.7245 0.8186 0.8809 10.9267 0.03 0.1588 0.3010 0.4060 0.4854 0.5590 J0.6174 0.6468 0.6517 0.6694 0.7255 0.8196 0.8820 0.9277 0.04 0.1618 0.3049 O.~15 0.4899 0.5634 0.6215 0.6503 0.6543 0.6712 0.7263 0.8204 0.8829 10.9286 0.05 0.1726 0.3166 O.U4191 0.49.69 70.S6

' --0-.6272 0.6345.'

O.6578 0.6737 O.Ij74 0.8215

o.

0884o~

0.92907 0.06 0.1756 0.3245 0.4287 0.5062 10.5784 0.6353 0.6613 0.6626 0.6770 0.7288 0.8230 0.8855 0.9310 0.07 0.1734 0.3260 0.4316 0.5102 0.5847 0.6436 0.6709 0.6707 0.6829 0.7308 0.8248 0.8873 0.9326 0.08 0.2211 0.3661 0.4687 0.5448 j0.6138 0.6657 10.6857 0.6783 0.6870 0.7346 0.8277 0.8897 0.9347 0.09 0.2218 0.3694 0.4787 0.5583 0.6307 0.6845 0.7055 0.6967 0.7020 0.7373 10.8300 0.8918 0.9367 0.10 0.2245 0.3470 0.4640 0.51 0.6299 10.6872 0.7103 0.7035 0.7095 0.7492 10.8379 0.8972 0.9408 0.11 0.2614 0.3630 0.4816 0.5694 0.6475 10.7051 0.7295 0.7220 0.7267 0.7646 10.8490 0.9052 0.9471 0.12 0.2829 0.3802 0.4879 0.5799 0.6610 10.7206 0.7455 0.7359 0.7397 0.7790 10.8597 0.9144 0.9540 0.13 0.3096 0.4199 0.5249 0.6177 0.6990 0.7571 10.7778 0.7635 0.7629 0.7966 0.8731 0.9256 0.9630 0.14 0.3457 0.4798 0.5514 0.6425 0.7230 0.7827 0.8047 0.7899 0.7887 0.8166 0.8876 0.9377 0.9725 0.15 10.3578 0.5127 0.5819 0.6409 0.7254 0.7905 0.8S177 j0.8059 0.8061 0.8254 0.8937 0.9447 0.9780 0.16

.0.3685 0.6084

-0Q.7671 0.8295 0.8580 0.8150 0.8187 j0.~1.11.1 0.8143 0.8257 0.8871 0.9420 0.9763 0.1-1 0.3873 0.5518 6.719 0.8179 0.824 0.8525 0.7498

.744 0.7689 0.79057-0.8650 0:0924.-v;.9671 0.18 0.3613 0.6315 0.8007 0.9304 0.9971 0.9584 0.8502 40.7664 07874 0.811I1 0.8700 0.9333 0.9706 0.19

.0.3659 0.6192 0.7890 0.8644 0.9285 10.9102 0.8173 0.7888 0.80-75 0.8286 0.8706 0.9350 0.9718 0.20 0.4039 0.6381 0.8372 0.9572 0.9887 10.9724 0.88191 0.8329 0.8472 0.8647 0.8824 0.9393 0.9742 0.21 0.4328 0.6559 0.8552 1.0105 1.0151 0.9578 0.9411 0.9320 0.9387 0.9459 0.9475 0.9567 0.9852 0.22 0.3998 0.6508 0.8056 0.9396 1.0445 1.0456 1.0505 1.0400 1.0424 1.0426 1.0341 0.9936 0.9860 0.23 0.3982 0.7028 0.9474 1.1148 1.1428 1.1204 1.1053 1.0999 1.1043 1.1036 1.0929 1.0483 1.0358 0.24 0.3988 0.6376 10.8893 1.0687 1.1334 1.0999 1.0979 1.1037 1.1149 1.1195 1.1140 1.0716 1.0613 0.25 0.4683 0.6360 10.8531 1.0178 1.0938 1.1347 1.0891 1.0302 1.0448 1.0583 1.0652 1.0355 1.0347 0.26 0.4933 0.6954 0.7874 0.9567 1.1212 1.1798 1.1413 1.0761 1.0444 1.0123 0.9653 0.9441 10.9587 0.27 0.4919 0.7709 0.8879 0.9671 1.0617 1.0861 1.0442 1.0490 1.0543 1.0594 1.0603 1.0290 11.0431 0.28 0.5137 0.8650 1.0120 1.0895 1.1754 1.2464 1.2709 1.2688 1.2703 1.2704 1.2637 1.2195 1.2198 0.29 0.5265 0.8618 1.0230 1.1360 11.2153 1.2946 1.3752 1.3836 1.3905 1.3936 1.3906 1.3434 1.3372 0.30 0.4849 0.7999 0.9858 1.1157 1.1902 1.2548 1.3506 123751 1.3939 1.4048 1.4114 1.3724 1.3677 0.31 0.5109 0.8269 1.0798 1.1911 1.2141 1.2650 1.2788 1.3177 11.3442 1.3631 1.3802 1.3511 1.3510 0.32 0.5246 0.8316 11.1521 1.3377 1.3647 1.2813 1.2443 1.2683 1.3000 1.3217 1.3450 1.3217 1.3252 0.33 0.5189 0.8861 11.2464 1.4677 1.5286 1.4397 1.2739 1.2493 1.2783 1.2983 1.3205 1.2968 1.3016 0.34 0.4781 0.8884 11.2569 1.4992 1.5932 1.5315 1.3643 1.2973 1.3142 1.3260 11.3384 1.3062 11.3084 0.35 0.4292 0.8678 1.2301 1.4849 1.6099 1.5758 1.4246 1.4288 1.4316 1.4349 1.4358 1.3902 1.3878 0.36 0.4055 0.8087 1.1439 1.4027 1.5535 1.5478 [1.5961 1.5860 1.5834 1.5843 1.5815 1.5274 1.5223 0.37 0.3563 0.6849 0.9850 1.2349 11.4579 1.6280 1.7075 1.6975 1.6983 1.7043 1.7080 1.6534 1.6499 0.38 0.3510 0.7139 1.0190 1.2655 1.4818 1.6515 1.7368 1.7378 1.7490 1.7647 1.7805 1.7343 1.7352 0.39 0.3470 0.7012 0.9946 1.2272 1.4309 1.6013 1.6971 1.7150 1.7395 1.7675 1.8002 1.7670 1.7738 0.40 0.3299 0.6617 0.9325 1.1443 1.3373 1.5095 1.6204 1.6568 1.6953 1.7360 1.7860 1.7655 1.7792 0.41 0.3125 0.6198 10.8673 1.1218 1.3950 1.5088 1.5663 1.6191 1.6685 1.7183 1.7797 1.7669

-1.7825 0.42 0.3044 0.5985 10.8372 1.1459 1.4448 1.5935 1.5872 11.6471 1.7032 1.7558 1.8200 1.8044 1.8184 0.43 0.3046 0.5990 10.8450 1.1407 1.4551 1.6331 1.6626 1.7235 1.7907 1.8333 1.8958 1.8746 1.8845 0.44 0.3045 0.6039 0.8627 1.0979 1.3782 1.6072 1.7297 1.7901 1.8491 1.9027 1.9647 1.9398 1.9498 0.45 0.2986 0.5982 0.649 1.1109 1.3735 1.6043 1.7517 1.8143 1.8761 1.9322 1.9976 1.9758 1.9880 0.46 0.2882 0.5818 0.8494 1.0970 1.3580 1.5846 1.7311 1.7986 1.8646 1.9247 1.9962 1.9814 11.9981 0.47 0.2766 0.5607 0.8238 1.0677 1.3228 1.5431 1.6896 1.7628 1.8342 1.8990 11.9770 1.9711 1.9923 0.48 0.2660 0.5397 0.7962 1.0354 1.2829

.1.4974 1.6449 1.7250 1.8007 1.8699 11.9537 1.9568 1.9826 0.49 0.2569 0.5204 0.7704 1.0041 1.2456 1.4562 1.6048 1.6907 1.7707 1.8431 11.9333 1.9432 1.9732 0.50 0.2489 0.5030 10.7465 0.9752 1.2111 1.4179 1.5681 1.6594 1.7421 1.8117 11.9130 1.9295 1.9638 0.51 I0.2420 0.4870 0.7242 0.9477 1.1789 11.3827 1.5339 1.6286 1.7148 1.7927 1.8921 1.9155

-1.9528 0.52 0.2360 0.4725 10.7035 0.9223 1.1482 1.3491 1.5008 1.5987 1.6874 1.7675 1.8715 1.9007 1.9410 0.53 0.2308 0.4596 0.6846 0.8985 1.1199 1.3174 1L4693 1.5703 1.6609 1.7430 1.8512 1.8858 11.9292 0.54 0.2265 0.4480 0.6673 0.8766 1.0937 1.2879 1.4398 1.5433 1.6357 1.7196 1.8316 1.8714 11.9178 0.55 0.2227 0.4378 0.6516 0.8566 1.0693 1.2604 1.4120 11.5175 1.6115 1.6971 1.8125 1.8573 1.9066 0.56 0.2196 0.4287 0.6374 0.8381 1.0466 1.2348 1.3860 11.4930 1.5886 1.6758 1.7944 1.8440 1.8959 0.57 0.2168 0.4207 0.6245 0.8212 1.0257 1.2112 1.3618 1.4700 1.5672 1.6560 11.7776 1.8317 1.8863 0.58 0.2143 0.4138 0.6128 0.8057 1.0064 1.1894 1.3394 1.4491 1.5473 1.6376 1.7623 1.8203 1.8775 0.60 0.2350 0.4543 10.6133 0.7766 0.9704 1.1486 1.2972 1.4096 1.5101 1.6028 1.7326 1.7966 1.8588 0.62 0.2481 0.4836 0.6569 0.7807 0.9342 1.1073 1.2544 1.3679 1.4699 1.5639 1.6964 1.7674 1.8336 0.64 0.2446 0.4821 0.6601 0.7905 0.9003 1.0687 1.2128 I1.3267 1.4291 1.5236 1.6592 1.7368 1.8086 0.-66 10.2298 0.4593 0.6355 0.7665 0.8812 1.0395 1.1811 f1.2951 1.3979 I1.4936 [1.6334 1.'7190o 1.7962

Calc Number: GEO.H-BIP.03.02 Rev Number: 0 Sheet Number: 50 of -349

~Date: 08/27/03 0.68 J0.2081 0.4233 0.5941 0.7439 10.9947 I 1.0208 I 1.1609 1125 L7 147 11.6231 11.7168 11.7985 0.70 J0.1839 0.3868 0.5793 0.7495 0.9031 1.0179 ]1.1449 1.2606 j 1.3668

-11.46-76 11.6186 11.7192-1~1.8047 0.72 0.1811 0.3738 0.5627 0.7301 0.8835 1.0019j 1.1259 1.2427 11.3504 1.4-539 j 1.6094 11.7153 11.8043 0.74j 0.1776 0.3492 0.5289 0.6894 0.8494 0.9687J 1.1025 1.2200 11.3292 1.4345 11.5935 11.7037 J 1.7954 0.76 0.1736 0.3316 0.4865 0.6517 0.8309 0.9818 I1.0833 1.1956 11.3059 1.4123 11.5742 11.6885 J 1.7832 0.78 0.1695 0.3240 0.5007 0.6911 0.8785 1.0349 1.1383 1.1978, 1.2834 1.3908 1.5552 1.6734 31.7710 1:

0.80, 0.1655 -f0lltV6 0.4640

-0.6-403 0.8130 0.9559 4..1.487 1.1509

  • .1.2625.

13708 {1.5378 ~-1,6599 11.7605 0.82 0.1616 0.3096 0.4535 0.5944 0.7405 0.8811 11.0118 1.1302 1.2423 1.3516 1.5210 1.6470 11.7504 0.84 0.1578 0.3026 0.4434 0.5812 0.7242 0.8624 0.9916 1.1102 1.2226 1.3330 1.5047 1.6343 11.7404 0.86 0.1542 0.2961 0.4338 0.5688 0.7090 0.8448 0.9728 1.0916 1.2046 1.3160 11.4900 1.6232 11.7321 0.88 0.1509 0.2901 0.4252 0.5576 0.6954 0.8293 0.9565 1.0757 1.1894 1.3019 11.4785 1.6157 11.7274 0.90 0.1478 0.2847 0.4175 0.5479 0.6836 0.8161 0.9428 1.0627 1.1775 1.2913 1.4706 1.6118 11.7261 0.92 0.1450 0.2798 0.4106 0.5392 0.6731 0.8044 0.9309 1.0516 1.1677 1.2829 1.4653 1.6100 11.7268 0.94 0.1421 0.2748 0.4036 0.5305 0.6626 0.7927 0.9190 1.0405 1.1577 1.2744 1.4594 1.6076 11.7265 0.96 0.1389 0.2694 0.3960 0.5209 0.6512 0.7799 0.9055 1.0276 1.1455 1.2632 1.4501 1.6009 11.7217 0.98 0.1354 0.2635 0.3875 0.5101 0.63-79 0.7646 0.8892 1.0113 1.1292 1.2474 1.4351 1.5879

1.7097 1.00 0.1316.

0.2571 0.3783 0.4980 j0.6227 0.7469 0.8699 0.9911 1.1086 1.2263 1.4138 1.5676 11.6897 1.05 0.1227 0.2418 0.3553 0.4663 j0.5814 0.6971 0.8134 0.9301 1.0434 1.1574 1.3403 1.4928 11.6142 1.10 0.1154 0.2284 0.3361 0'44T00 4ifU.5460 10.6528'-

e07613 0.8718 U.9795 1.0883 1.2648 1-1A149 1.5350.,

1.15 0.1115 0.2190 0.3230 10.42'25 0.52'27 10.6228 0.7250 0.8304 0.9341 1.0392 1.2119 11.3620 1.4836 1.20

.I2 0.2135 0.3135 10.4105 0.5070 10.6026 0.7000 0.8017 0.9028 1.0059 1.1776 11.3304 1.4554 1.25 0.1180 0.2246 0.319-2 10.3968 0.4902 10.5819 0.6748 0.7727 0.8710 0.9720 1.1428 11.2980 1.4236 1.30 0.1211 0.2327 0.3351 0.4212 0.4927 0.5541 0.6418 0.7346 0.8290 0.9265 1.0939 1.2486 1.3764 1.35 0.1188 0.2280 0.3306 0.4197 0.4967 0.5583 0.6327 0.7144 0.8004 0.8866 1.0365 1.1829 1.3095 1.40 0.1108 0.2136 0.3096 0.3964 0.4813 0.5593 0.6316 0.7062 0.7851 0.8651 11.0071 1.1440 1.2633 1.45 0.1059 0.2061 0.2994 0.3862 0.4704 0.5480 0.6194 0.6904 0.7648 0.8405 10.9753 1.1033 1.2147 1.50 0.1005 0.1969 0.2877 0.3729 0.4557 0.5326 0.6030 0.6717 0.7427 0.8151 10.9436 1.0644 11.1687 1.55 0.0960 0.1913 0.2776 0.3610 0.4427 0.5190 0.5888 0.6560 0.7245 0.7943 10.9178 1.0329 11.1316 1.60 0.1039 0.2064 0.2989 0.3751 0.4394 10.5094 0.5790 0.6454 10.122 0.7800 10.8998 11.0107 1.1054 1.65 0.1016 0.2019 0.2927 10.3668 0.4304 10.5033 0.5725 0.6385 0.7041 0.7705 10.88,74 0.9955 1.0873 1.70 0.0908 0.1818 0.2722 10.3589 0.4415 0.5193 0.5843 0.6369 0.6972 0.7624 10.8769 10.9831 1.0727 1.75 0.0850 0.1799 0.2-760 0.3642 0.4463 0.5275 0.5979 0.6563 0.7050 0.7527 10.8650 10.9696 11.0575 1.80 0.0813 0.1723 0.2681 0.3630 0.4520 0.5302 0.6019 0.6621 0.7127 0.7564 10.8500 10.9532 11.0397 1.85 0.0796 0.1705 0.2652 0.3592 0.4483 0.5275 0.5925 0.6508 0.7011 0.7450 10.8327 10.9343 11.0 19'2 1.90 0.0763 0.1619 0.2522 0.3433 0.4310 0.5107 0.5781 10.6314 0.6775 0.7332 10.8186 0.9138 10.9966 1.95 0.0711 0.1505 0.2334 0.3207 0.4055 10.4835 0.5500 0.6100 10.6731 0.7315 10.8230 0.8924 0.9720 2.00 0.0652 0.1376 0.2161 0.2961 0.3753 0.4528 0.5274 0.5985 0.6637 0.7239 10.8194 0.8933 10.9456 2.05 0.062.

0.1303 0.2035 10.2811 0.3594 0.4373 0.5128 0.5846 0.6501 0.7104 10.8070 0.8828 0.9305 2.10 0.0599 0.1245 0.1929 0.2676 0.3452 0.4219

-0.4957 0.5660 0.6302 0.6896 10.7855 0.8616 0.9110 2.15 0.0567 0.1182 0.1835 0.2547 0.3293 0.4032 0.4742 0.5421 0.6045 0.6624 10.7566 0.8324 0.8830 2.20 0.0534 0.1117 0.1738 0.2399 0.3107 0.3811 0.4489 0.5141 0.5770 0.6424 10.7446 0.8181 0.8629 2.25 0.0501 0.1051 0.1641 0.2260 0.2898 0.3602 0.4381 0.5168 0.5892 0.6544 10.7545 0.8244 0.8647 2.30 0.0468 0.0988 0.1547 0.2136 0.2736 10.3339 0.4057 0.4780 10.5440 0.6028 10.69 15 0.7552 0.7965 2.35

.0.0440 0.0929 0.1455 0.2012 0,2584 10.3156 0.3714 0.4261 10.4789 0.5301 10.6234 0.7084 10.7816 2.40 0.0412 0.0871 0.1366 0.1890 0.2433 0.2979 0.3519 0.4060 10.4593 0.5115 10.6074 0.6940 10.7686 2.50 0.0386 0.0772 0.1192 0.1655 0.2140 10.2651 0.3200 0.3764 10.4303 0.4822 10.5778 0.6653 10.7416 2.60 0.0364 0.0730 0.1107 10.155-2 0.2009 10.2490 0.2997 0.3526 10.4041 0.4541 10.5476 0.6347 0.7122 2.70 0.0342 0.0689_

0.1039 0.1438 0.1868 0.2319 0.'2793 0.3-291 0.3781 0.4261 0.5169 0.6030 10.6802 2.80 0.0321 0.0650 0.0981

0. 131B5 0.1717 10.2142 0.2589 0.3060 0.3527 0.3986 0.4858 0.5693 10.6449 2.90 0.0301 0.0612 0.0926 0.1243 0.1564 0.1966 0.2389 0.2832 0.3272 0.3706 0.4532 0.5330 10.6059 3.00 0.0282 0.0574 0.0871 0.1173 0.1474 0.1792 0.2186 0.2600 0.3010 0.3415 0.4190 0.4944 10.5638 3.10 0.0263 0.0538 0.0819 0.1105 0.1393 0.1681 0.1981 0.2362 0.2741 0.3117 0.3837 0.4542 10.5200 3.20 0.0245 0.0503 0.0768 0.1040 0.1315 0.1590 0.1867 0.2149 0.2470 0.2816 0.3479. 10.4136 10.4756 3.30 0.0227 0.0469 0.0719 0O.097 0.1240 0.1503 0.1767 0.2033 10.2301 0.2569 0.3 127 10.3760 10.4544 3.40 0.0211 0.0436 0.0672 0.0918 0.1168 0.1419 0.1669 0.1922 0.2174 0.2427 0.2917 10.3568 10.4311 3.50 0.0195 0.0406 0.0629 0.0861 0.1098 0.1336 0.1574 0.1812 0.2051 0.2289 0.2752 10.3232 10.3914 3.60 0.0180 0.0377 0.0588 0.0807 0.1030 0.1256 0.1481 0.1706 0.1930 0.2155 0.2592 10.3020 10.3430 3.70 0.0167 0.0352 0.0549 0.0755 0.0965 0.1178 0.1390 0.1602 0.1813 0.2025 0.-2436 10.2840 10.3226 3.80 0.0155 0.0328 0.0512 0.0705 0.0902 0.1103 0.1303 0.1502 0.1700 0.1899 10.2285 0.2665 0.3029 3.90 0.0144 0.0305 0.0477 0.0657 0.0843 0.1031 0.1219 0.1406 0.1592 0.1778 0.2140 0.2498 0.2839 4.00 0.134 0.0284 0.0444 0.0613 0.0786 0.0962 0.1138 0.114 10.1488 0.1663 0.2002 0.2338 0.2659 4.10 0.0124 0.0264 0.0413 0.0570 0.0732 0.0897 0.1062 0.1227 0.1390 0.1553 0.1871 0.2186 0.2487 4.20 0.0115 0.0245 0.0384 0.0531 0.0682 0.0836 0.0991 0.1145 0.1297 0.1450
0. 1747 0.2042 022 4.30 0.0107 0.0227 0.0357 0.0493 J0.0634 0.0779 0.0923 0.1067 0.1210-0.1353 0.1630 0.1906

~~

4.40 0.0099

~0.0211 0.0331 0.0459 1 0.0590 10.0725 0.0860 0.0995 0.1128 0.1261,0.15'21 10.1779

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 51 of 349 Date: 08/27/03 4.50 3 0.0092 0.0196 0.0308 0.0427 0.0549 0.0675 0.0801 0.0927 0.1052 0.1176 0.1418 0.1661 0.1896 4.60 0.0088 0.0182 0.0286 0.0397 0.0511 0.0629 0.0747 0.0864 0.0980 0.1097 0.1323 0.1550 0.1776 4.70 0.0092 0.0186 0.0279 0.0371 0.0476 0.0586 0.0696 0.0806 0.0914 0.1023 0.1234 0.1447 0.1674 4.80 0.0097 0.0196 0.0297 0.0396 0.0494 0.0590 0.0682 0.0783 0.0890 0.0995 0.1196 0.1395 0.1629 4.90 0.0098 0.0200 0.0304 0.0408 0.0512 0.0614 0.0714 0.0813 0.0922 0.1034 0.1250 0.1473 0.1726 5.00 0.0094 0.0194 0.0298 0.0403 0.0508 0.0614 0.0717 0.0819 0.0922 0.1033 0.1256 0.1487 0.1745 5.10, 0.0088 0.0181 0.0279-0.0380 0.0480-] 0.0587 0.0690

'-0.0792 0.0893

-0:0995-0.1216 0.144i 0.A687 5.20 0.0079 0.0163 0.0252 0.0344 0.0440 0.0538 0.0636 0.0736 0.0833 0.0929 0.1134 0.1350 0.1570 5.40 0.0070 0.0144 0.0223 0.0304 0.0388 0.0474 0.0562 0.0652 0.0742 0.0831 0.1006 0.1182 0.1361 5.60 0.0060 0.0123 0.0192 0.0264 0.0339 0.0417 0.0499 0.0582 0.0666 0.0750 0.0915 0.1082 0.1252 5.80 0.0056 0.0114 0.0174 0.0235 0.0298 0.0363 0.0427 0.0492 0.0557 0.0630 0.0776 0.0925 0.1075 6.00 0.0052 0.0106 0.0162 0.0219 0.0278 0.0338 0.0398 0.0459 0.0519 0.0579 0.0691 0.0800 0.0905 6.20 0.0049 0.0099 0.0151 0.0204 0.0259 0.0315 0.0371 0.0428 0.0484 0.0541 0.0646 0.0748 0.0846 6.40 0.0047 0.0094 0.0142 0.0191 0.0242 0.0294 0.0341 0.0400 0.0453 0.0506 0.0604 0.0700 0.0791 6.60 0.0043 0.0087 0.0132 0.0178 0.0227 0.0276 0.0325 0.0375 0.0424 0.0474 0.0566 0.0656 0.0752 6.80 0.0040 0.0081 0.0123 0.0167 0.0212 0.0258 0.0305 0.0352 0.0398 0.0444 0.0531 0.0615 0.0711 7.00 0.0038 0.0076 0.0116 0.0157 0.0199 0.0242 0.0286 0.0330 0.0374 0.0417 0.0499 0.0578 0.0663 7.20 0.0035 0.0071 0.0109 0.0147 0.0187 0.0228 0.0269 0.0311 0.0352 0.0393 0.0469 0.0544 0.0615 7.40'-' A.0033 0.0067

  • 0.002 0.0139 0.0176 0.0215 0.0253 *0.0293 0.0331 r.0370

>Ft'.0442 0.0513 0:0580 7.60 0.0031 0.0063 0.0097 0.0131 0.0166 0.0203 0.0239 0.0276 0.0313 0.0349 0.0417 0.04S4 0.0547 7.80 0.0030 0.0060 0.0091 0.0124 0.0157 0.0191 0.0226 0.0261 0.0295 0.0330 0.0394 0.0457 0.0517 8.00 0.002S 0.0057 0.0086 0.0117 0.0149 0.0181 0.0214 0.0247 0.0279 0.0312 0.0373 0.0433 0.0489 8.50 0.0025 0.0049 0.0075 0.0102

'0.0130 0.0158 0.0187 0.0216 0.0245 0.0273 0.0327 0.0379 0.0429 9.00 0.0022 0.0044 0.0067 0.0090 0.0115 0.0140 0.0165 0.0191 0.0216 0.0241 0.0289 0.0335 0.037S 9.50 0.0019 0.0039 0.0059 0O0080 0.0102 0.0124 0.0147 0.0169 0.0192 0.0215 0.0257 0.0297 0.0336 10.00 0.0017 0.0035 0.0053 0.0072 0.0091 0.0111 0.0131 0.0152 0.0172 0.0192 0.0229 1 0.0266 0.0301

Calc Number: GEOHBMIP.03.02 Rev Number: 0 Sheet Number: 52 of 349 Date:- 08/27/03 Table 6-8b. Soil Spectr~a for M=7.0, Set 2, Lower Vs SoilProfile Per (sec) 0.1g 0.!

G.3w 0.4g 0.5s!

0.6g-0.7g 0.8q I0.9ig 1.0O 1.2g 1.4g 1.61Z 0.01 0.1464 0.2618 10.3389 0.4302 0.5312 0.6118 0.6765 0.7273 0.7589 0.7744 10.7887 J0.8030 10.8147 0.03 0.1472 0.2659 1-0.3440 0.4335 0.5352 0.6163 0.6811 0.7318 0.7633 0.7782 10.7920 j0.8061 10.81.82 0.04 0.1~26 0.2702 0.3486 0.4359 0.3389 0.6206 0.6853 0.7361 0.7674 0.7820 10.7951 j 0.8090 0.8213 0.05 0.11589 0.2649 0.3425 0.4360 0.5411 0.6244 0.6908 0.7412 0.7729 0.79173 'FEY7954

- 0.812S

-g~T 0.06 0.1896 0.2861 0.3565 0.4326 0.5350 0.6226 0.6915 0.7448 0.7770 0.7926 10.8050 0.8179 0.8303 0.07 0.1911 0.3156 0.3898 0.4546 0.5506 0.6308 0.6969 0.7487 0.7815 0.7972 10.8102 0.8232 0.8365 0.08 0.1874 0.3146 0.3991 0.4362 0.5396 10.6276 0.6987 0.7543 0.7897 0.8057 10.8194 0.8317 0.8446 0.09 0.2307 0.3374 0.4214 0.5213 0.6097 0.6801 0.7364 0.7799 0.8039 0.8144 0.8236 0.8351 0.8552 0.10 0.2582 0.3662 0.4208 0.5164 0.6240 0.7069 0.7697 0.8180 0.8419 0.8506 0.8517 0.8583 10.8555 0.11 0.3332 0.4959 0.5785 0.5948 0.5849 0.6701 0.7375 0.7904 0.8219 0.8355 0.845 I 0.85-70 10.8600 0.12 0.3395 0.5320 0.6366 0.6800 0.7096 0.7772 0.8272 0.8641 0.8797 0.8821 0.8816 0.8867 0.8781 0.13 0.2977 0.4480 0.5792 0.6760 0.7762 0.8467 0.89719 0.9337 0.9474 0.9479 0.9409 0.9405 0.9249 0.14 0.3876 0.5330 0.6557 0.7402 0.7685 0.8103 0.8706 10.9162 0.9408 0.9485 10.9518 0.9563 0.9425 0.15 0.3954 0.5645 0.7341 0.8555 0.9064 0.9298 0.9365 0.9094 0.8777 0.8986 10. 9186 0.9325 0.9266 0.16

.0.4107 0.6042 0.7668

.0.8660 0.9109

.0.9193-09593 0.9438.

0.8917

-0.8724 10.9013 0.9199 10.9210 0.17 0.4034 0.6783 0.8631 0.9585 0.9659 0.9459 0.9334, 0.9338 0.8915 0.8630 0.8937 0.9313 0.9663'-

0.18 0.4650 0.86 0.9161 0.9898 1.0471 1.0579 1.0377 1.0390 0.9996 0.9523 0.9407 0.9631 0.9818 0.19 0.4158 0.6877 0.9227 1.0449 1.1554 1.2219 1.2666 1.2773 1.2380 1.1724 1.0452 1.0478 1.0557 0.20 0.3785 0.6698 0.9080 1.0767 1.2142 1.2948 1.3514 1.3818 1.3540 1.2945 1.1608 1.1514 1.1267 0.21 0.4159 0.7181 0.9376 1.1161 1.2629 1.3553 1.4050 11.4256 1.4053 1.3538 1.3017 11.2906 1.2557 0.22 0.4074 0.7034 0.9916 1.1864 1.2911 1.4213 1.5196 11.5754 1.5676 1.5206 1.4602 11.4429 1.4005 0.23 0.4291 0.7205 1.0385 1.2458 1.3726 1.4770 1.5388-1.5508 1.5317 11.5561 11.5493 1.53 16 1.4854 0.24 0.4712 0.7513 1.0104 1.2636 1.4814 1.6230 1.7052 1.7370 1.6875 1.5996 11.4723 1.4635 11.4278 0.25 0.4807 0.7839 0.9795 1.2318 1.4621 1.6366 1.7491 1.8032 1.7655 1.6782 1.5434 1.5091 1.4517 0.26 0.5644 0.9164 1.1095 1.1613 1.36180 11.5716 1.7064 1.7759 1.7571 1.6839 1.5569 1.5260 1.5315 0.27 0.5660 0.9512 1.1822 1.2643 1.3054 11.3409 1.3792 1.4763 1.5053 1.4721 1.3933 1.4161

.1.4376 0.28 0.5634 0.9850 1.2358 1.3252 1.3934 1.4279 1.5108 1.6012 1.6374 1.6309 1.5996 1.6299 1.6397 0.29 0.5662 0.9957 1.2439 1.3560 1.4577 1.5068 1.5424 1.6347 1.6712 1.6724 1.6627 1.6699 1.6254 0.30 0.5228 0.9102

.1.1474 1.3157 1.4416 1.5159 1.5507 1.6247 1.6735 1.6857 11.7071 1.7318 1.6951 0.31 0.5271 0.9243 1.2053 1.4245 1.5526 1.5910 1.61,64 i1.6361 1.6007 1.5601 1.6085 1.6451 1.61I77 0.32 0.5681 0.9497 1.2909 1.5673 1.7451 1.8066 1.8110 1.7931 1.7139 1.6388 1.6101 1.6779 1.7213 0.33 0.5858 0.9925 1.3998 1.7328 1.9312 2.0202 2.0532 2.0641 1.9956 1.8838 1.7659 1.7857 1.7922 0.34 0.5211 0.9565 1.3742 1.7058 1.9117 12.0229 2.083-2 2.1188 2.0755 1.9775 1.8813 1.9055 1.8969 0.35 0.4819 0.9376 1.3468 1.6759 1.8874 12.0136 2.0871 2.1388 2.1107-2.0846 2.0595 2.0882 2.0822 0.36 0.4637 0.9018 1.2977 1.6187 1.8583 12.0914 2.2382 2.3021 2.2512 2.1906 2.1757 2.2112 2.2061 0.37 0.4389 0.8622 1.2411 1.5377 1.7541 11.9916 2.1485 2.2271 12.2589 2.2518 12.2464 12.2858 2.2860 0.38 0.3923 0.7768 1.1068 1.4208 1.6909 11.91 07 2.0833 2.2092 12.2613 2.2630 12.2682 12.3152 2.3196 0.39 0.3520 0.7257 1.0608 1.4337 1.7854 2.0569 2.2338 2.3191 2.2952 2.2364 2.2542 12.3075 2.3172 0.40 0.3451 0.6924 1.0510

'1.4951 1.8804 2.1800 2.3806 2.4773 2.4555 2.3915 2.306_4 2.2930 2.3078 0.41 0.3343 0.6647 11.0348 1.4932 1.9027 2.2265 2.4447 2.5562 2.5367 2.4729 2.3910 2.4018 2.4096 0.42 0.3155 0.6381 10.9759 1.4372 1.8608 2.2022 2.4365 2.5524 2.5392 2.4768 2.4370 2.5103 2.5279 0.43 0.2911 0.6050 0.9005 1.3200 1.7545 2.1203 2.3783 12.5195 2.5209 2.4553 2.4908 2.5738 2.6031 0.44 0.2792 0.5647 0.8444 1.1663 1.5946 11.9582 2.2272 12.3863 2.4103 12.4068 2.4919 2.5822 2.6216 0.45 0.2856 0.5259 0.7871 1.0783 1.4068 1.7544 2.0669 12.3680 12.4972 2.4920 2.4931 2.5642 12.6126 0.46 0.2875 0.5220 0.7666 1.050Y2 1.3507 1.6893

-2.0462 2.3360 2.4617 2.4584 2.4639 12.5459 2.6067 0.47 0.2869 0.5178 0.7590 1.0312 1.3096 1.5714 1.8575 2.1195 2.2363 2.3128 2.4321 2.5416 2.6098 0.48 0.2844 0.5145 0.7554 1.0186 1.2878 1.5428 1.7899 2.0142 2.1914 2.2991 2.4263 2.5418 2.6180 0.49 0.2801 0.5166 10.7534 1.0094 1.2711 1.5212 1.7678 1.9949 2.1775 2.2907 2.4264 2.5465 2.6279 0.50 0.2735 0.5171 0.7503 0.9996 1.2542 1.4991 1.7442 1.9737 2.1600 2.2771 2.4194 2.5440 2.6310 0.51 0.2697 0.5141 0.7435 0.9854 1.2326 1.4723 1.7154 11.9443 12.1329 12.2524 2.3978 2.5250 2.6158 0.52 0.2669 0.5084 0.7327 0.9677 1.2067 1.4391 1.6773 1.9044 12.0923 2.2127 12.3613 2.4907 2.5862 0.53 0.2630 0.3010 0.7207 0.9475 1.1781 1.4034 1.6361 1.8587 2.0453 2.1657 2.3164 2.4476

. 2.5476 0.54 0.2589 0.4935 0.7083 0.9279 1.1495 1.3672 1.5944 1.8131 1.9977 2.1182 2.2699 2.4025 12.5071 0.55 0.2552 0.4871 0.6971 0.9097 1.1234 1.3330 1.5546 1.7695 1.9521 2.0727 2.2267 2.3611 12.4701 0.56 0.2654 0.5176 0.6950 0.8946 1.1009 1.3036 1.5198 1.7313 1.9127 2.0340 2.1910 2.3281 2.4430 0.57 0.2882 0.5598 0.7518 0.8829 1.0822 1.2791 1.4905 1.6999 1.8812 2.0042 2.1657 2.3068 2.4287 0.58 0.3062 0.5936 0.7976 0.9333 1.0638 1.2553 1.4626 1.6-708 1.8531 1.9786 2.1462 2.2925 2.4214 0.60 0.3212 0.6212 0.8355 0.9805 1.1604 1.3157 1.4563 1.5862 1.7693 1.8993 2.0788 2.2343 2.4280 0.62 0.2990 0.5810 0.7968 1.0251 1.2342 1.4172 1.5937 1.7549 1.8842 1.9587 2.0346 2.1423 2.3514 0.64 0.2585 0.30 076 1.0121 1.2221 1.4151

-1.6-093 1.7911 1.9389 2.0243 2.1096 12.2163 2.4145 0.66 0.2331 0.493

.7 0.37 1.1354 1.3249 1.5212 11.7094 1.8639 1.51 2038 212

.212

Calc Number: GEO.HB[P.03.02 Rev Number: 0 Sheet Number: 53 of 349 Date: 08/27/03 I j 0.68 I 0.2098l 0.44271 l0657 l 0.8484 l 1.0354 4

1.2210 l 1.4151 1 1.6(24 l 1.7584 1.8521 1 1.9373 1 2.0235 7 -

w ANAL i

2.1800 I 0.70 0.1952 0.4118 0.6146 0.8049 10.9942 I1.I1846 1.3822 1.5725 1.7322 1.8277 11.9065 1.9809

2. 1224 0.72 0.1900 042 0.6083 0.8074 1.0067 1-12065 1.41231 1.611I4 1.7786 1.87671 1.9491 2.137 2.1484 0.74 0.1865 0.3972 0.6088 0.8170 1.0249 ]1.2316 j1.4440 1.6508 1.8257 1.9266 1.9924 2.0484 2.1777 0.76 0.1790 0.3844 0.5971 0.8093 1.0194 J1.2275 1.4409 1.6506 1.8303 1.9323 1.9904 2.03 -;6 2.1580 0.78 0.1647 0.3578 0.5633 0.7712 0.9759 1.1774 1.3836 1.5884 1.7652 1.8660 1.9146 1.9768, 2.0905 0.80 0.1429' 0.3142 0.5028

.0.6963 0.8863 1

.07-15 ~-I~.26S2 1.4539

-.,6190-1.7299

.817.IT 1.8738 1.9762 0.82 0.1304 0.2744 0.4224 0.3928 0.7691 I0.9544 1.1391 1.3214 1.5002 1.6548 1.8457 1.9265 2.0006 0.84 0.1282 0.2637 0.4099 0.5933 0.7913 0.9947 1.1963 1.3968 135932 1.7594 1.9530 2.0280 2.1022 0.86 0.1215 0.2536 0.3935 0.5411 0.7261 0.9221 1.1186 1.3150 1.5074 1.6663 1.8419 1.9343 2.0343 0.88 0.1318 0.2506 0.3687 0.4933 0.6353 0.7806 0.9361 1.1085 1.2893 1.4558 1.6772 1.8995 2.1060 0.90 0.1421 0.2723 0.4029 0.5267 0.6382 0.7500 0.8786 1.0294 1.2038 1.3855 1.7127 1.9514 2.1646 0.92 0.1439 0.2816 0.4183 0.5497 0.6683 0.7842 0.9116 1.0570 11.2237 1.3974 1.7134 1.9486 2.1610 0.94 0.1443 0.2800 0.4173 0.5510 0.6720 0.7886 0.9129 1.0517 1.2088 1.3-71-7 1.6695 1.8956 2.1027 0.96 0.1400 0.2728 0.4076 0.5400 0.6602 0.7749 0.8949 1.0267 1.1739 1.3255 1.6048 1.8211 2.0216 0.98 0.1356 0.2648 0.3964 0.5269 0.6455 0.7581 0.744 L1.00013.1393 1.2820 1.5470 1.7567 1-9539 1.00 0.1316 0.2575 0.3864 0.5151 0.6328 0.7441 0.8578 0.9791 1.1122 1.2487 1.5044 1.7112 1.9078 1.05 0.1195 0.2347 0.3544 0.4772 0.5909 0.6980 0.8050 0.9159 1.0350 1.1578 1.3939 1.5920 1.7827

'1.10 0.116 027 0.3349 0.4525~'

0.5625 0.66358"'

0I.7676 0.8704

' 0.97 5 1.0904 If1&

'+5004 1.6850~

1.15 0.1256 0.2366 0.3452.0.4604 0.5715 0.6774 0.7824 0.8865 0.9930 1.1033 1.3269 1.5269 1.7239 1.20 0.1416 0.2677 0.3840 0.4915 0.5843 0.6679 10.7505 0.8515 0.9537 1.0582 1.2741 1.4733 1.6705 1.25 0.1410 0.2689 0.3891 0.5025 0.6009 0.6904 0.7796 0.8668 0.9473 1.0169 1.1422 1.3091 1.4881 1.30 0.1322 0.2533 0.3684 0.4788 0.5756 0.636 0.7511 0.8370 0.9168 0.9863 1.1085 1.2288 1.3685 1.35 0.1230 0.'2359 0.3433 0.4473 0.5397 0.6240 0.7074 0.7893 0.8657 0.9330 1.0505 1.1606 1.2843 1.40

0. 1 112 0.2250 0.3276 0.4257 0.5118 0.5883 0.6672 0.7448 0.8177 0.8824 0.9957 1.0982 11.2118 1.45 0.1228 0.2372 0.3447 0.4467 0.5357 0.6145 0.6924 0.7697 0.84-21 0.9049 1.0168 1.128-2 1.-2466 1.50 0.1299 0.2507 0.3628 0.4678 0.5585 0.6380 0.7168 0.7948 0.8683 0.9324 1.0459 L1.570 1.2737 1.55 0.1261 0.2431 0.3501 0.4492 0.5328 0.6054 0.6774 0.7487 0.8161 0.8758 0.9826 1.0855 1.1970 1.60 0.1079 0.2117 0.3097 0.4008 0.4752 0.5350 0.5961 0.6554 0.7077 0.7573 0.8689 0.9639 1.0656 1.65 0.0978 0.2011 0.3058 0.4059 0.4936 0.5679 0.6352 0.6957 0.7452 0.8080 0.9293 1.0330 1.1283 1.70 0.0944 0.1953 0.2974 0.3951 0.4788 0.5563 0.6410 0.7205 0.7903 0.8450 0.9719 1.0823 1.1841 1.75 0.0860 0.1794 0.2761 0.3748 0.4707 0.5601 0.6453 0.7261 0.7976 0.8621 0.9966 1.1117 1L18 1.80o 0.0838 0.1741 0.2672 0.3614 0.4568 0.5468 0.6311 0.7097 0.7889 0.8666 1.0043 1.1221 1.231 1.85 0.0774 0.1611 0.2508 0.3441 0.43-72 0.5252 j 0.6094 0.6960 0.7797 0.8578 0.9966 3.1155 1.2254 1.90 0.0744 0.1555 0.2412 0.3300 0.4191 0.5065 (0.5925 0.6775 0.7601 0.8375 0.9761 1.0952 1.2054 1.95 0.0709 0.1482 0.2301 0.3154 0.4012 0.4858 0.5691 0.6517 0.7324 0.8087 0.9468 1.0659 1.1762 2.00 0.0667 0.1395 0.2169 0.2979 0.3798 0.4610 0.5413 0.6210 0.6996 0.7748 0.9126 1.0322 1.1426 2.05 0.0620 0.1299 0.2025 0.72788 0.3567 0.4345 J0.5116 0.5886 0.6651 0.7394 0.8171 0.9969 1.1070 2.10 0.0571 0.1202 0.1880 0.2597 0.3339 0.4086 0.4829 0.5572 0.6316 0.7045 0.8408 0.9597 1.0687 2.15 0.0527 0.1116 0.1751 0.2426 0.3131 0.3847 0.4559 0.5'272 0.5989 0.6697 0.8032 0.9203 1.0281 2.20 0.0500 0.1044 0.1638 0.22'71 0.2937 0.3616 0.4294 0.4974 0.5660 0.6343 0.7645 0.8798 0.9867 2.25 0.0478 0.0994 0.1538 0.2118 0.2743 0.3385 0.4026 0.4673 0.5330 0.5989 0.7260 0.8400 0.9462 2.30 0.0457 0.0951 0.1474 0.2019 0.2585 0.3161 0.3762 0.4378 0.5008 0.5646 0.6892 0.8019 0.9077 2.35 0.0437 0.0911 0.1413 0.1938 0.2483 0.3039 0.3596 0.4159 0.4730 0.5324 0.6545 0.7659 0.871 2.40 0.0418 0.0873 0.1354 0.1858 0.2383 0.2919 0.3458 0.4002 0.4554 0.5109 0.6218 0.7322 0.8375 2.50 0.0380 0.0797 0.1239 0.1703 0.2188 0.2684 0.3183 0.3688 0.4203 0.4721 0.5975 0.7254 0.8504 2.60 0.0344 0.0722 0.1125 0.1549 0.1994 0.2451 0.2910 0.3376 0.3889 0.4469 0.5692 0.6883 0.8046 2.70 0.0307 0.0648 0.1012 0.1397 0.1802 0.2220 0.2640 0.3066 0.3503 0.3945 0.4815 0.5638 0.6656 2.80 0.0273 0.0576 0.0903 0.1249 0.1616 0.1995 0.2376 0.2764 0.3162 0.3566 0.4364 0.5110 10.5843 2.90 0.0271 0.0564 0.0866 0.1170 0.1478 0.1793 0.2123 0.2473 0.2834 0.3201 0.3928 0.4793 0.5756 3.00 0.0258 0.0539 0.0835 0.1135 0.1441 0.1752 0.2071 0.2399 0.2735 0.3082 0.3836 0.4664 0.5563 3.10 0.0247 0.0492 0.0767 0.1050 0.1339 0.1632 0.1933 0.2243 0.2564 0.2895 0.3599 0.4357 0.5178 3.20 0.0233 0.0467 0.0705 0.0954 0.1213 0.1484 0.1761 0.2047 0.2352 0.2682 0.3396 0.4133 0.4910 3.30 0.0205 0.0414 0.062.8 0.0854 0.1091 0.1339 0.1593 0.1853 0.2129 0.2427 0.3072 0.3737 0.4437 3.40 0.0182 0.0367 0.0550 0.0733 0.0931 0.1153 0.1378 0.1605 0.1841 0.2093 0.2654 0.3234 0.3845 3.50 0.0166 0.0332 0.0496 0.0669 0.0865 0.1070 0.1279 0.1494 0.1719 0.1953 0.2443 0.2981 0.3524 3.60 0.0163 0.0325 0.0489 0.0673 0.0869 0.1075 0.1286 0.1503 0.1733
0. 1977 0.2490 0.3004 0.3521 3.70 0.0161 0.0327 0.0492 0.0658 0.0836 0.1031 0.1235 0.1446 0.1671 0.1914 0.2429 0.2949 0.3475 3.80 0.0152 0.0311 0.0477 0.0650 0.0827 0.1005 0.1183 0.1360 0.1565 0.1793 0.2281 0.2780 0.3289 3.90 0.0146 0.0299 0.0460 0.0628 0.0803 0.0980 0.1157 0.1335 0.1516 0.1702 0.2088 0.2526 0.3002 4.00 0.0135 -0.0277 0.0428 0.0587 0.0753 0.0922 0.1093 0.1266 0.1442 0.1622 0.1996 0.2371 0.2746 4.10 0.0124 0.0252 0.0389 0.0535 0.0690 0.0849 0.1009 0.1173 0.1340 0.1512 0.1865 0.2220 0.2576 4.20 0.0113 0.0229 0.0352 0.0482

-0.0623 0.077.0 0.0919 0.1072 0.1229 0.1390 0.1720 02050L0.2383 4.30 0.0102 0.0207 0.0318 0.0435 0.0561 0.0695 10.0832 10.0972 0.1118 0.1267 0.1571 0.1876 0.2136 4.40 10.0092 0.0185 0.0285 0.0391 0.0504.

0.0625 10.0750 10.0878

_0.1012_

0.1148 0.1428019

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 54 of 349 Date: 08/27/03 4.50 0.0089 0.0183 0.0279 0.0378 0.0480 0.0585 0.0691 0.0797 0.0912 0.1037 0.1294 ] 0.1551 0.1816 4.60 0.0086 0.0176 0.0270 0.0368 0.0468 0.0572 0.0677 0.0784 0.0893 0.1003 0.1224 0.1443 10.1667 4.70 0.0081 0.0164. 0.0251 0.0343

-0.043S 0.0537 0.0638 0.0741 0.0848 0.0957 0.1176 0.1392 0.1613 4.80 0.0077 0.0155 0.0234 0.0316 0.0404 0.0495 0.0588 0.0683 0.0783 0.0887 0.1099 0.1308 0.1519 4.90 0.0074 0.0150 0.0227 0.0303 0.0381 0.0460 0.0540 0.0620 0.0707 0.0802 0.1000 0.1196 0.1393 5.00 0.0072 0.0146 0.0221 0.0297 0.0375 0.0453 0.0533 0.0613 0.0694 0.0775 0.0931 0.1079 0.1260 510 0.0071 0.0142 140:0214 0.0287

'0.0361 0.0438 0;0515 0.0594 0.0674 0.0754 0.0912 04106!1.0.1206 5.20 0.0069 0.0139 0.0209 0.0280 0.0352 0.0426 0.0499 0.0571 0.0643 0.0720 0.0874 0.1021 0.1176 5.40 0.0064 0.0130 0.0197 0.0264 0.0328 0.0393 0.0466 0.0540 0.0614 0.0687 0.0831 0.0974 0.1118 5.60 0.0060 0.0122 0.0185 0.0248 0.0309 0.0370 0.0432 0.0501 0.0571 0.0641 0.0780 0.0916 0.1055 5.80 0.0056 0.0113 0.0171 0.0230 0.0287 0.0344 0.0403 0.0462 0.0521 0.0583 0.0717 0.0851 0.0987 6.00 0.0051 0.0103 0.0157 0.0211 0.0264 0.0317 0.0371 0.0425 0.0481 0.0538 0.0662 0.0786 0.0912 6.20 0.0046 0.0093 0.0142 0.0192 0.0240 0.0288 0.0337 0.0387 0.0438 0.0491 0.0604 0.0718 0.0833 6.40 0.0044 0.0085 0.0127 0.0172 0.0215 0.0259 0.0303 0.0348 0.0394 0.0442 0.0544 0.0648 0.0753 6.60 0.0044 0.0085 0.0126 0.0166 0.0204 0.0241 0.0278 0.0313 0.0351 0.0393 0.0485 0.0579 0.0673 6.80 0.0043 0.0084 0.0125 0.0165 0.0203 0.0241 0.0278 0.0315 0.0349 0.0381 0.0442 0.0511 0.0595 7.00 0.0042 0.0082 0.0121 0.0160 0.0199 0.0236 0.0273 0.0310 0.0344 0.0377 0.0439 0.0501 0.0569 7.20 0.0040 0.0078 0.0116 0.0154 0.0191 0.0228 0.0264 0.0300 0.0334 0.0367 0.0428 0.0489 0.0552 7.40 0.0038 0.0074 '; 0.0110 0.0146 0.0182

-0.0217 0.0212

':0287 0.0320 0.0332 0.0412 0.0471 0.0533 7.60 0.0035 0.0069 0.0103 0.0138 0.0172 0.0205 0.0238 0.0271 0.0303 0.0334 0.0391 0,0448 0.0512 7.80 0.0033 0.0064 0.0096 0.0128 0.0160 0.0192 0.0223 0.0254 0.02S7 0.0320 0.0385 0.0449 0.0514 8.00 0.0030 0.0060 0.0089 0.0119 0.0150 0.0181 0.0212 0.0244 0.0276 0.0309 0.0373 0.0436 0.0499 8.50 0.0027 0.0054 0.0082 0.0111 0.0139 0.0168 0.0197 0.0227 0.0257 0.0286 0.0345 0.0405 0.0464 9.00 0.0025 0.0050 0.0076 0.0103 0.0130 0.0158 0.0185 0.0214 0.0242 0.0271 0.0329 0.0385 0.0440 9.50 0.0022 0.0044 0.0066 0.0089 0.0112 0.0136 0.0160 0.0185 0.0211 0.0237 0.0290 0.0348 0.0405 10.00 0.0019 0.0039 O.OOSS 0.0078 0.0098 0.0119 0.0140 0.0162 0.0184 0.0207 0.0256 0.0307 0.0359

Calc Number: GEO.HBIBP.03.02 Rev Number: 0 Sheet Number: 55 of 349 Date: 08/27/03 Table 6-8c. Soil Soectra for M=7.0. Set 3. Lower Vs Soil Profile ptr1 0.01 0.1629 0.2843 0.3771 0.4578 j0.5236 0.5758 0.6192 0.6511 0.6724 0.6838 0.7163 0.7598 0.7724 0.03 0.1664 0.2894 0.3819 0.4623 0.5280 0.5799' 0.6231 0.6549 0.6761 0.6873 0.7178 0.7613 0.7739 0.04 0.1723 0.2958 0.3873 0.4670 I0.5323 0.5839 0.6268 0.6584, 0.6794 0.6904 0.7191 0.7627 0.7753

'TO 0.'17-69~ 0.3018 0.3931 0.4735 0.5380 0.5892 0.6313 0.'6625 0.6832 0.6946

-0.720-9 0.7645 0.7771I 0.06 0.1903 0.3189 0.4066 0.4848 0.5473 0.5973 0.6380 0.6687 0.6888 0.6999 0.7230 0.7667 0.7793 0.07 0.1882 0.3213 0.4122 0.4927 0.5579 0.6071 0.6481 0.6774 0.6971 0.7073 0.7258 0.7695 0.7820 0.08 0.2071 0.3411 0.4353 0.5153 0.5769 0.6230 0.6615 0.6890 0.7074 0.7166 0.7280 0.~7722 0.7850 0.09 0.2192 0.3347 0.4353 0.5 196 0.5832 0.6313 0.6707 0.6986 0.7171 0.7260 0.7296 0.7746 0.7879 0.10 0.2415 0.3841 0.4561 0.5403 0.6049 0.6524 0.6894 0.7165 0.7336 0.7406 0.7352 0.7792 0.7921 0.11 0.2619 0.4370 0.4964 0.5691 0.6324 0.6780 0.7128 0.7389 0.7548 0.7599 0.7499 0.7843 0.7970 0.12 0.2926 0.4332 0.5234 0.5654 0.6365 0.6863 0.7233 O.'7503 10.7672 0.7740 0.7627 0.7861 0.8000 0.13 0.3226 0.4411 0.5309 0.5881 0.6594 0.7084 0.7446 0.7723 0.7887 0.7942 0.7811 0.7893 0.8038 0.14 0.3465 0.4568 0.5233 0.5982 0.6740 0.7260 0.7640 0.7920 0.8089 0.8132 0.7993 0.7930 0.8081 0.15 0.4071 0.4936 0.6242 0.6553 0.6797 0.7338 0.7725 0.8034 0.8216 0.8277 0.8135 0.799-2 0.8092 0.16 0.4233 0.5379 0.6697 0,&95 0.6665 0.7132.

0.7589 0.7955.

0.8175 0.8265

0.

8175 0.8063 0.816 0.17 0.4244 0.6292 0.7855 0.8082 0.7558 0.7844 0.8262 0.8550 0.8725 0.8789 0.8648 0.8473 0.49 0.18

.D.4239 0.6995 0.8898 0.9355 0.8799 0.8989 0.9316 0.9535 0.9657 0.9668 0.9405 0.9099 0.8772 0.19 0.3946 0.6315 0.8368 0.9033 j0.9004 0.9494 0.9807 1.0039 1.0173 1.0156 0.9870 0.9521 0.9153 0.20 0.4528 0.6511 0.9051 1.0018 31.0019 0.9932 1.0020 1.0275 1.0427 1.0417 1.0132 0.9783 0.9405 0.21 0.4519 0.7334 0.8677 0.9405 0.9784 0.9696 0.9960 1.0257 1.0417 1.0453 1.0201 0.9887 0.9538 0.22 0.4785 0.7956 0.9560 1.0094 1.0416 1.0398 0.9836 0.9665 0.9921 1.0023 0.9883 0.9754 0.9671 0.23 0.4859 0.7733 0.8817 0.9850 0.9903 0.9903 1.0004 1.0469 1.0938 1.1163 1.1079 1.0663 1.0055 0.24 0.5054 0.7667 10.9493 1.0999 1.0961 1.0885 1.0793 11.1221 1.1661 1.1851 1.1726 1.1198 1.0477 0.25 0.5112 0.8155 0.9-765 1.0826 1.1606 1.1743 1.1430 1.1246 1.1562 1.1670 1.1467 1.1156 1.0781 0.26 0.5058 0.8363 1.0101 1.1152 1.2008 1.2242 1.2000 1.1665 1.1812 1.1944 1.1750 1.1450 1.1105 0.27 0.5126 0.8671 1.0508 1.1737 1.2725 1.3070 1.2888 1.2591 1.2473 1.2600 1.2418 1.2111 1.1725 0.28 0-5222 0.8849 1.0703 1.2255 1.3397 1.3846 1.3733 1.3477 1.3094

'1.3105 1.2941 1.2622 1.2216 0.29 0.5094 0.8556 1.0563 1.2454 1.3694 1.4260 1.4221 1.4022 1.3683 1.3317 1.3 187 1.2881 11.2481 0.30 0.4658 0.8168 1.0452 1.2528 1.3886 1.4536 1.4561 1.4445 1.4162 1.3613 1.3421 1.3136 1.274~5 0.31 0.4498 0.7793 11.0402 1.2543 1.4008 1.4741 1.4859 1.4798 1.4569 1.4077 1.3671 1.3412 1.302 0.32 0.5049 0.8883 1.1203 1.2651 1.4102 1.4920 1.5133 1.5139 1.4959 1.4492 1.3953 1.3718 1.3348 0.33 0.5057 0.9382 1.2076 1.3469 1.4308 1.5218 1.5494 1.5571 1.5440 1.5002 1.4405 1.4165 1.3811 0.34 0.4561 0.8930 1.1673 1.3641 1.4572 1.5580 1.5923 1.6086 1.6013 1.5635 1.4991 1.4754 1.4396 0.35 0.4395 0.8635 1.1411 1.3370 1.4722 1.5825 1.6284 1.6530 1.6532 1.6187 1.5536 1.5304 1.4948 0.36 0.4280 0.8703 1.1591 1.3020 1.4949 1.6162 1.6740 1.7072 1.71-24 1.6836 1.6190 1.5963 1.5608 0.37 0.3987 0.8521 1.2016 1.3830 1.5335 1.6692 1.7352 1.7769 1.7891 1.7645 1.7064 1.6832 1.6482 0.38 0.3872 0.8440 1.1974 1.4378 1.5639 1.7053 1.7851 1.8366 1.8559 1.8353 1.7812 1.7625 1.7268 0.39 0.3453 0.7506 1.1364 1.4382 1.6376 1.7805 1.8643 1.9241 1.9560 1.9469 1.8477 1.8111 11.7799 0.40 0.3392 0.6876 1.0573 1.3527 1.5561 1.6892 1.7699 1.8350 1.8782 1.8833 1.8534 1.8449 1.8170 0.41 0.3344 0.6380 0.9379 1.1979

-1.4327 1.6124 1.7298 1.8210 1.8775 1.8919 1.8742 1.8699 1.8460 0.42 0.3279 0.6250 0.8883 1.1352 1.3783 1.5714 1.7035 1.8104 1.8773 1.9038 1.8927 1.8949 1.8769 0.43 0.3207 0.6130 0.8732 1.0991 1.3352 1.5444 1.6935 1.8134 1.8948 1.9321 1.9271 1.9329 1.9181 0.44 0.3130 0.6005 0.8617 1.0926 1.3035 1.5260 1.6914 1.8259 1.9193 1.9681 1.9631 1.9719 1.9608 0.45 0.2990 0.5784 0.8368 1.0704 1.2867 1.4866 1.6650 11.8098 1.9141 1.9737 1.9869 1.9990 1.9897 0.46 0.2799

. 0.5429 0.7871 1.0109 1.2218 1.4050 1.5856 11.7377 1.8485 1.9177 1.9741 2.0375 2.0247 0.47 0.2777 0.5402 0.7858 1.0084 1.2160 1.3903 1.5146 1.6538 1.8218 1.9393 2.0418 2.0705 2.0356 0.48 0.781 0.5294 0.7708 0.9894 1.1911 1.3577 1.4867 1.7026 1.8805 2.0073 2.1227 2.1624 2.1371 0.49 0.2781 0.5298 0.7669 0.9672 1.1622 1.3220 1.4336 1.6394 1.8225 1.9558 2.0892 2.1435 2.1324 0.50 0.2639 0.5115 0.7469 0.9519 1.1420 1.2971 1.4058 1.5539 1.7329 1.8688 2.0139 2.0810 2.1058 0.51 0.2606 0.5052 0,7338 0.9396 1.1267 1.2797 1.3878 1.5017 1.6523 1.7821 1.9206 2.0029 2.0289 0.52 0.2557 0.4960 0.7210 0.9238 1.1083 1.2596 1.3676 1.4822 1.5903 1.6773 1.8028 1.8785 1.8877 0.53 0.2490 0.4840 0.7044 0.9033 1.0843 1.2332 1.3403 1.4538 1.5608 1.6471 1.7707 1.8454 186 0.54 0.274 0.4789 0.6878 0.88-24 1.0594 1.2049 1.3098 1.4210 1.5259 1.6105 1.7319 1.8062 O

1.8 0.55 0.2857 0.5038 0.6747 0O.8654 1.0384 1.1807 1.2833 1.3921 1.4950 1.5779 1.6994 1.7744 1.7798 0.56 0.2873 0.5105 0.6653 0.8527 1.0226 1.1623 1.2635 1.3706 1.4724 1.5556 1.6783.1.7552 1.8039 0.57 0.2837 0.5071 0.6574 0.8419 1.0093 1.1473 1.2478 1.3541 1.4560 1.5399 1.6649 1.7455 1.7855 0.58 0.2770 0.4973 0.6486 0.8305 0.9956 1.1323 1.2325 1.3389 1.4411 1.5253 1.6526 1.7365 1.7489 0.60 0.2520 0.4573 0.6278 0.8051 0.9664 1.1001 1.1988 I-1.3047 1.4063 1.4909 1.6219 1.7088 1.7250 0.62 0.2283 0.4259 0.6105 0.7930 0.9400 1.0712 1.1690-

-1.2735 11.3747 1.4598 1.5925 1.6822 1.7007 0.64 0.2253 0.4424 0.6087 0.7625 0.9161 1.0452 1.1421 1.2466 1.3476 1.4328 1.5686 1.6615 1.6833 0.66 0.2181_

0.4355 1 0.5944 0.7368

_0.8874 1.0149 1.1115 1.2148 1.3155 1.4014 1.5391 1.6343 11.6594

Calc Number: GEO.HIBIP.03.02 Rev Number: 0 Sheet Number: 56 of '349

~~~~~~~~~Date:

08127/03 0.68 i 0.1959 0.3809 0.5532 0.7126 0.8610 0.9868 1.0826 11.1852 11.2848 11.3698 115083 i 1.6051

1. 6312 0.70 0.1899 0.3697 0.5443 0.6969 0.8440 0.9685 1.0633 1.1651 1.2639 11.3488 11.4875 11.5845 1.6117 0.72 0.1856 0.3627 0.5463 0.6979 0.8330 0.9561 1.0499 1.1504 1.2498 1.3337 1.4739 11.5730 1.6013 0.74 0.YS114 035 0.5221 0.67160 0.8198 0.9404 11.0324 1.1321 1.2303 123158 1.4584 11.5601 j1.5914 0.76 0.1764 0.3466 0.5083 0.6599 0.8001 0.9182 J1.0091 1.1087 1.2067 1.2925 1.4370 1.5410 1.57498 0.78 0.1706 0.3361 0.4934 0.6412 0.7780 0.8939

-0.9853 1.0847 1.1825 1.2681 1.4136 11.518-7 1.5539 0.280 0.1652 0.3259 0..4794 0.6237~ O.)180 0.8734

'0.96547 -1.0645 1.1618 1:2470 1.3928 11.4985 1.5346 0.82 0.1602 0.3 170 10.46'70 0.6089 0.7419 0.8575

- 09495 1.0478 1.1441 1.2290 1.3750 11.4817 1.51 S7 0.84 0.1552 0.3082 0.4551 0.949 0.7269 0.8421 0.9334 1.0302 1.1253 11.2097

1. 3562 11.4643 1.5028 0.86 0.1494 0.2978 0.4412 0.5784 0.7194 0.8452 0.9393 1.0209 1.1013 11.1850 11.33-21 11.4410 1.4809 0.88 0.1425 0.2852 0.4240 0.5711 0.7239 0.8559 0.9566 11.0449 1.1194 1.1764 1.2998 11.4088 1.4493 0.90 0.1346 0.2706 0.4053 0.5627 0.7173 0.8528 0.9585 1.0523 1.1323 1.1949 1.2821 1.3684 1.4093 0.92 0.1280 0.2556 0.3931 0.5469 0.7006 10.8373 0.9462 1.0441 1.1282 1.1952 1.2908 11.3282 1.3651 0.94 0.1290 0.2523 0.3791 0.5268 0.6771 0.8132 0.9238 1.0239 11.1105 1.1805 1.2829 11.3279 1.3215 0.96 0.1297 0.2485 0.3700 0.5060 0.6513 0.7852 0.8960 0.9967 11.0844 1.1560 1.2639 11.3163 1.2839 0.98 0.1292 0.2439 0.3630 0.4875 0.6265 0.7568 0.8666 0.967 1.0546 1.1274 I.39

.99I.26 1.00 0.1280 0.2407 0.3558 0.4725 0.6045 0.7306 0.8385 0.9380 1.0255 1.0989 1.2158 1.2823 1.2678 1.05~.0.1241 0.2350 0.3404 0.4506 0.5634 0.6782 0.7813 0.8786 0.9656 1.041 1.1676 1.2479 1.2506 1-.10 0.1252 0.2331 0.3293 0.43270:S530 0.6401 0.7j89' 0:8341-0.9202; -. 9?r6i 1.1297 122199.1.2373 1.15

-0.1306 0.2444 0.3394 0.4153 0.5131 10.6111 10.7061 0.7978 0.8816 0.9577 1.0932 1.1921 1.2251 1.20 0.1279 0.2402 0.3372 0.4139 0.4989 10.59-19 0'.6834 0.7715 0.524 0.9272 11.0637 1.1698 1.2167 1.25

-0.1214 0.2279-0.3228 0.4014 0.4900 0.5792 0.6679 10.7537 0.8329 0.9068 11.0442 11.1556 1.2130 1.30 0.1188 0.2204 0.3110 0.3946 0.4813 0.5675 0.6544 0.7395 0.8184 0.8924 11.0309 11.1463 1.2123 1.35 0.1136 0.2140 0.3092 0.3953 0.4770 0.5587 0.6427 0.7270 0.8057 0.8798 1I.018 11.1368 1.2099 1.40 0.1091 0.2118 0.3073 0.3940 0.4742 0.5518 0.6311 0.71-27 0.7899 0.8630 1.0009 1.1199 11.19813 1.45 0.1056 0.2052 10.2989 0.3851 0.4642 0.5389 0.6137 0.6916 0.7663 0.8375 0.9729 1.0916

1. 1730 1.50 0.1003 0.1956 10.2859 0.3702 0.4477 10.5198 0.5905 0.6644 0.7362 0.8048 0.9363 1.0528 1.1345 1.55 0.0940 0.1845 10.2709 0.3525 0.4279 10.4975 0.5648 0.6350 0.7036 0.7694 0.8959 1.0083 1.0876 1.60 0.0898 0.1821 10.2693 0.3453 0.4084 0.4759 0.5405 0.6075 0.6730 0.7360 0.8510 0.9643 1.0396 1.65 0.0936 0.1893 0.2780 0.3533 0.4130 0.4578 0.5205 0.5850 0.6480 0.7083 0.8240 0.9263 0.9977 1.70 0.0906 0.1831 0.2676 0.3376 0.3909 0.4448 0.5064 0.5690 10.6300 0.6881 10.7992 0.8973 0.9662 1.75 0.0819 0.1654 0.2410 0.30-27 0.3721 0.4368 0.4977 0.5591 10.6184 0.6748 10.7825 0.8777 10.9452 1.80 0.0748 0.1505 0.2292 0.3103 0.3836 0.4429 0.4928 0.5532 10.61 14 0.6664 10.7715 0.8648 10.9315 1.85 0.0731 0.1476 0.2215 0.2975 0.3662 0.4287 0.4890 0.5487 10.6059 10.6599 10.7628 10.8544 10.9203 1.90 0.0713 0.1444 10.2176 0.2900 0.3595 10.4243 0.4842 0.5431 1 0.5993 10.6522 10.7530 0.8427 0.9072 1.95 0.0692 0.1407 10.2128 0.2845 0.3534 10.4176 0.4767 0.5346 0.5897 10.6414 10.7397 0.8270 10.8899 2.00 0.0667 0.1361 0.2067 0.2771 0.3448 0.4078 0.4760 0.5413 0.6006 10.6531 0.7421 0.8067 10.8680 2.05 0.0639 0.1307 0.1990 0.2676 0.3335 0.4079 0.4800 0.5465 0.6069 10.6606 0.7524 0.8197 10.8456 2.10 0.0608 0.1245 0.1901 0.2561 0.3303 0.4061 0.4776 0.5437 0.6038 10.6576 0.7505 0.8194 10.8488 2.15 0.0575 0.1177 0.1802 0.2490 0.3242 0.3981 0.4681 0.330 0.5922 10.6455 0.7393 0.8114 10.8463 2.20 0.0540 0.1106 0.1710 0.2409 0.3133 0.3847 0.4527 0.5163 0.5748 0.6281 0.7240 0.7999 10.8402 2.25 0.0505 0.1033 0.1631 0.2296 0.2985 0.3672 0.4339 0.4973 10.5561 0.6102 10.7075 0.7852 0.8289 2.30 0.0470 0.0971 0.1533 0.2159 0.2813 10.3480 0.4153 0.4789 10.5376 0.5915 10.6879 0.7658 0.8118 2.35 0.0446 0.0937 0.1457 0.2012 0.2639 0.3302 0.3973 0.4600 10.5175 0.5702 10.6646 10.7418 10.7896 2.40 0.0427 0.0900 0.1401 0.1936 0.2496 0.3135 0.3788 0.4395 10.4952 0.5462 10.6381 0.7284 0.7819 2.50 0.0386 0.0820 0.1288 0.1784 0.2303 0.2839 0.3389 0.3946 10.4519 10.5123 10.6240 0.7188 10.7864 2.60 0.0349 0.0746 0.1178 0.1634 0.2111 0.2603 0.3095 0.3573 0.4169 0.4761 10.5922 0.7010 10.7905 2.70 0.0320 0.0674 0.1069 0.1487 0.1923 0.2374 0.2828 0.3293 0.3872 0.4458 0.5622 0.6733 10.7669 2.80 0.0299 0.0605 10.0963 0.1345 0.1743 0.2155 0.2576 0.3023 0.3556 0.4093 0.5169 0.6234 0.7185 2.90 0.0279 0.0562 0.0863 0.1211 0.1573 0.1952 0.2367 0.2782 0.3258 0.3758 0.4777 0.5808 0.6807 3.00 0.0261 0.05-27 0.0796 0.1088 0.1440 0.1818 0.2223 0.2623 0.3013 0.3446 0.4415 0.5406 0.6366 3.10 0.0245 0.46 0.0752 0.1011 0.1343 0.1702 0.2087 0.2469 0.2842 0.3208 0.4014 0.4917 0.5784 3.20 0.0231 0.0468 0.0712 0.0959 0.1250 0.1588 0.1951 0.2312 10.2665 0.3013 0.3697 0.4398 0.5312 3.30 0.0217 0.0443 0.0675 0.0911 0.1158 0.1474 0.1814 0.2152 10.2484 10.28II1 0.3457 0.4090 0.4873 3.40 0.0205 0.0419 0.0641 0.0867 0.1093 0.1360 0.1676 0.1991 10.2301 10.2607 0.3215 0.3814 0.4378 3.50 0.0194 0.0398 0.0609 0.0825 0.1041 0.1259 0.1541 0.1833 10.2120 10.2405 10.2975 10.3543 0.4084 3.60 0.01 84 0.0378 0.0579 0.0785 0.0993
0. 1201 0.1413 0.1679 10.1945 10.2210 0

'.2745 0.3284 0.3801 3.70 0.0175 0.0360 0.0552 0.0748 0.0947 0.1146 0.1348 0.1549 0.1778 10.2025 10.2529 10.3039 0.3530 3.80 0.0167 0.0343 0.0526 0.0714 0.0904 0.1095 0.1287 0.1478 0.1665 0.1853 10.232-7 0.2806 0.3272 3.90 0.0159 0.0328 10.0502 0.0681 0.0863 0.1045 0.1229 0.1411 0.1588 0.1762 0.2139 0.2587 0.3029 4.00 0.0152 0.0313 0.0479 0.0650 0.0824 0.0999 0.1174 0.1347 0.1516 0.1682 0.2009 0.2381 0.2802 4.10 0,0145 0.0299 0.0458 0.0620 0.0787 0.0954 0.1122 0.1287 0.1449 0.1606 0.1918 0.2226 0.2597 4.20 0.0139 0.0285 0.0437 0.0592 0.0751 0.0912 0.1072 0.1230 0.1385 0.1535 0.1834 0.2130 )0.2428 4.30 0.0132 0.0272 0.0417 0.0565 0.0718 0.0871 I0.1025 0.1176 10.1324 0.1469 0.1756 0-011021 4.40 0.0126 0.0260 I0.0398 0.0540 0.0685 0.0833 1 0.0980 10.1125 10.1267 0.1406 1.63101981022

Calc Number: GEO.IBIP.03.02 Rev Number: 0 Sheet Number: 57 of 349 Date: 08/27/03 4.50 0.0120 0.0247 - 0.0379 0.0515 ! 0.0655 0.0796 0.0 9 3 7 0.1077 0.1213 0.1347 0.1614 0.ate:

0.2140 4.60 0.0114 0.0235 O.0361 0.0492 [0.0625 0.0761 0.0897 0.1031 0.1162 0.1292 0.1549 0.1807 0.2060 4.70 0.0108 0.0224 0.0344 0.0469 [ 0.0597 0.0727 0.0858 0.0987 0.1114 0.1239 0.1488 0.1737 0.1924 4.80 0.0103 0.0213 0.0328 0.0448 0.0570 0.0695 0.0820 0.0945 0.1068 0.1188 0.1429 0.1671 0.1911 4.90 0.0098 0.0202 0.0312 0.0427 0.0545 0.0664 0.0785 0.0905 0.1023 0.1140 0.1373 0.1608 0.1841 5.00 0.0093 0.0192 0.0297 0.0407 0.0520 0.0635 0.0751 0.0867 0.0981 0.1094 0.1320 0.1547 0.1773 5.10

_ 008 0.0183 0.0283'-

0.0389 0.0497 0.0607 0.0718

  • 0.0830 0.0940 0.1050 014i268

-0.1488 0.707-5.20 0.0083 0.0173 0.0269 0.0370 0.0474 0.0580 0.0687 0.0795 0.0901 0.1007 0.1218 0.1431 0.1643 5.40 0.0075 0.0156 0.0244 0.0337 0.0432 0.0529 0.0628 0.0728 0.0827 0.0925 0.1123 0.1321 0.1520 5.60 0.0067 0.0141 0.0221 0.0306 0.0394 0.0482 0.0574 0.0666 0.0758 0.0849 0.1033 0.1218 0.1403 5.80 0.0060 0.0127 0.0200 0.0278 0.0358 0.0439 0.0523 0.0608 0.0694 0.0778 0.0949 0.1120 0.1291 6.00 0.0054 0.0114 0.0181 0.0253 0.0326 0.0400 0.0477 0.0555 0.0634 0.0712 0.0869 0.1027 0.1186 6.20 0.0050 0.0103 0.0164 0.0229 0.0296 0.0364 0.0434 0.0506 0.0578 0.0650 0.0795 0.0940 0.1090 6.40 0.0048 0.0098 0.0151 0.0208 0.0269 0.0331 0.0396 0.0461 0.0527 0.0593 0.0726 0.0859 0.1015 6.60 0.0046 0.0094 0.0143 0.0192 0.0244 0.0301 0.0360 -0.0420 0.0480 0.0540 0.0662 0.0791 0.0942 6.80 0.0044 0.0088 0.0135 0.0181 0.0228 0.0276 0.0329 0.0384 0.0440 0.0496 0.0607 0.0732 0.0871 7.00 0.0041 0.002 0.0126 0.0169 0.0213 0.0258 0.0307 0.0359 0.0412 0.0466 0.0572 0.0675 0.0804 7.20 0.0037 0.0076 0.0116 0.0156 0.0197 0.0238 0.0284 0.0332 0.0382-0.0431 0.0531 0.0626 0.0741 7.40 020034 0.0070 0.0106 0.0143 0.0180 0102i8 0.0260 0.0304 - 0.0349 0.0395 -0.0487 0.0575 0:0681 7.60 0.0032 0.0065 0.0099 0.0133 0.0168 0.0201 0.0236 0.0276 0.0317 0.0359 0.0442 0.0525 0.0625 7.80 0.0031 0.0062 0.0095 0.0128 0.0161 0.0194 0.0226 0.0260 0.0294 0.0328 0.0398

-0.0481I 0.0573 8.00 0.0029 0.0059 0.0091 0.0123 0.0155 0.0186 0.0218 0.0251 0.0284 0.0317 0.0381 0.0443 0.0526 8.50 0.0027 0.0054 0.0082 0.0112 0.0141 0.0169 0.0198 0.0229 0.0259 0.0289 0.0349 0.0406 0.0459 9.00 0.0024 0.0049 0.0074 0.0101 0.0128 0.0154 0.0180 0.0208 0.0236 0.0264 0.031S 0.0371 0.0419 9.50 0.0022 0.0044 0.0068 l 0.0092 0.0116 0.0140 0.0164

-0.0189 0.0215 0.0240 0.0290 0.0337 0.0381.

10.00 0.0020 I 0.0040 0.0062 0.004 0.0106 0.0127 0.0149 0.0172 0.0195 0.0218 0.0263 0.0306 0.0346

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 5 8 of 349 Date: 08/27/03 Table 6-9a. Soil SDectra for M=7.8. Set 1. Lower Vs Soil Profile Per (sec) I 0.1-

.2 0.3R i

.4t O.Se

.6g 0.7e 0.8S 0.9g 1.2 1.4 1l 0.0

0. 1643 0.2926 0.3977 0.4470 0.4x46 0.5131 0.5108 0.4947 0.4962 0.4943 0.4830 0.4932 J 0.5375 0.03 0.1672 0.2940 0.4001 0.4499 0.4875 0.510.5 1.5136 0.4976 0.4981 0.4959 0.4839 0.4939 0.53X3

. 0.04 0.1739 0.2953 0.4024 0.4523 0.4902 0.5187

&A.5162 0.5002 0.4998 0.4973 0.4847 1 0.4946 0.5390 0.05 0.1790 0.2953 0.4048 0.4556 0.4943 0.5225 1 0.5 197 0.5036 0.5022 1 0.4992 1 0.4859 1 0.4954 0.539

.1 0.06 0.1713 0.3022 0.4061 0.4575 0.4983 0.5268 0.5239 0.5077 0.5050 0.5017 0.4874 0.4964 0.5409 0.07 0.1922 0.3103 0.4083 0.45S7 0.5058 0.5333 0.5296 0.5132 0.5084 0.5047 0.4892 0.4976 0.5421 0.08 0.2286 0.3394 0.4148 0.4766 0.5276 0.5504 0.5428 0.5241 0.5123 0.5082 0.4914 0.4990 0.5436 0.09 0.2097 0.3644 0.4520 0.4S65 0.5296 0.5563 0.5494 0.5307 0.5165 0.5115 0.4960 0.5006 0.5454 0.10 0.24S0 0.4022 0.5002 0.5354 0.5469 0.5656 0.5593 0.5404 0.5361 0.5266 0.4991 0.5016 0.5470 0.11 0.2843 0.3975 0.4737 0.5338 0.5807 0.5992 0.5873 0.5645 0.5359 0.5287 0.5086 0.5020 0.5483 0.12 0.3008 0.4312 0.5006 0.5600 0.6088 0.6271 0.6128 0.5860 0.5544 0.5370 0.5158 0.5042 0.5499 0.13 0.3326 0.3873 0.4511 0.5136 0.5745 0.6043 0.5966 0.5741 0.5496 0.5459 0.5244 0.5103 0.5478 0.14 0.3373 0.3933 0.4851 0.5703 0.6355 0.6593 0.6432 0.6160 0.5850 0.5760 0.5440 0.5177 0.5532 0.15 0.3491 0.4966 0.5648 0.6291 0.6852 0.7006 0.6848 0.6814 0.6673 0.6475 0.5947 0.5317 0.5627 0,16 0.3618 -. 0.5.2-7 0.6303 0.6711

-0.6963 0.7111

.,0.7096 0.7064 0.6940 0.6754 0.6197.-S.5556 0.5718 0.17 0.3975 0.5584 0.6764 0.7151 0.7534 0.7747 0.7623 0.7153 0.6953 0.6691 0.628

-0:3720 0.5862 0.18 0.3974 0.5461 0.6773 0.7253 0.7677 0.7953 0.7858 0.7414 0.6783 0.6589 0.6336 0.5955 0.5655 0.19 0.4263 0.5803 0.6509 0.7099 0.7486 0.7676 0.7609 0.7193 0.6959 0.6861 0.6365 0.5747 0.5930 0.20 0.4579 0.6552 0.7945 0.8762 0.9166 0.9316 0.9308 0.9145 0.8946 0.8680 0.7820 0.6826 0.6092 0.21 0.4414 0.6953 0.8649 0.9798 1.0487 1.0687 1.0503 1.0054 0.9607 0.9322 0.8400 0.7387 0.6474 0.22 0.4310 0.7366 0.9301 1.0658 1.1489 1.1722 1.1513 1.1040 1.0398 0.9772 0.8372 0.7230 0.7109 0.23 0.4136 0.6974 0.8997 1.0451 1.1300 1.1606 1.1459 1.1019 1.0413 0.9819 0.8437 0.7943 0.7737 0.24 0.4260 0.6960 0.9546 1.0964 1.1541 1.1904 1.1777 1.1353 1.0940 1.0485 0.9575 0.8968 0.8625 0.25 0.4594 0.7586 0.9704 1.1370 1.1886 1.2146 1.2123 1.1869 1.1489 1.1114 1.0086 0.9178 0.8725 0.26 0.4731 0.7676 0.9755 1.1108 1.2040 1.2479 1.2466 1.2433 1.2121 1.1850 1.0989 0.9988 0.9055 0.27 0.4856 0.7648 0.9744 1.1089 1.2081 1.2568 1.2607 1.2420 1.2159 1.1958 1.1289 1.0411 0.9576 0.28 0.4770 0.7754 0.9884 1.1310 1.2364 1.2925 1.2973 1.2830 1.2568 1.2290 1.1374 1.0533 0.9901 0.29 0.5063 0.8204 1.0053 1.1572 1.2746 1.3369 1.3471 1.3314 1.3058 1.2806 1;1912 1.1074 1.0446 0.30 0.5112 0.9052 1.0762 1.1569 1.2769 1.3432 1.3526 1.3400 1.3'193 1.2985 1.2146 1.1357 1.0786 0.31 0.4774 0.9078 1.1360 1.2461 1.3329 1.3974 1.4278 1.4416 1.4276 1.3826 1.2553 1.1768 1.1211 0.32 0.4458 0.8441 1.0847 1.2155 1.3257 1.4002 1.4343 1.4556 1.4458 1.4064 1.2999 1.2226 1.1700 0.33 0.4344 0.7649 1.0134 1.1863 1.3233 1.4045 1.4267 1.4245 1.4139 1.4002 1.3237 1.2516 1.2046 0.34 0.4143 0.7531 0.9863 1.1636 1.3087 1.3962 1.4220 1.4213 1.4148 1.4042 1.3320 1.2672 1.2270 0.35 0.4266 0.7893 1.0172 1.1654 1.3112 1.4044 1.4324 1.4335 1.4281 1.4191 1.3499 1.2900 1.2548 0.36 0.4229 0.7877 1.0331 1.1999 1.3621

-1.4592 1.4856 1.4865 1.4814 1.4729 1.4028 1.3421 1.3057 0.37 0.4097 0.7737 1.0409 1.2516 1.4187 1.5169 1.5431 1.5424 1.5402 1.5336 1.4621 1.3993 1.3612 0.38 0.40S8 0.7971 1.0979 1.3213 1.4785 1.5742 1.5917 1.5847 1.5707 1.5558 1.4870 1.4262 1.3921 0.39 0.4023 0.8238 1.1818 1,4202 1.5914 1.7184 1.7821 1.8026 1.7910 1.7528 1.5538 1.4507 1.4212 0.40 0.3948 0.8257 1.2025 1.5310 1.7645 1.9061 1.9783 2.0044 1.9976 1.9607 1.7443 1.5260 1.4411 0.41 0.3755 0.7971 1.2512 1.6009 1.8528 2.0097 2.0921 2.1264 2.1279 2.0969 1.8806 1.6446 1.5510 0.42 03421 0.7534 1.2031 1.5557 1.8180-1.985]

2.0765 2.1207 2.1336 2.1145 1.9185 1.6839 1.6023 0.43 03110 0.6750 1.1020 1.4504 1.7175 1.8917 1.9915 2.0449 2.0680 2.0629 1.8972 1.6759 1.6160 0.44 0.2931 0.5955 1.0009 1.3463 1.6203 1.8032 1.9134 1.9733 2.0065 2.0114 1.8741 1.6964 1.6455 0.45 0.2946 0.5538 0.90S4 1.2541 1.5360 1.7276 1.8434 1.9147 1.9564 1.9719 1.8593 1.7492 1.7034 0.46 03056 0.5467 0.8130 1.1558 1.4424 1.6406 1.7655 1.8445 1.8922 1.9158 1.8354 1.8085 1.7668 0.47 0.3145 0.5532 0.7826 1.0409 1.3252 1.5258 1.6556 1.7410 1.7948 1.8446 1.8801 1.8550 1.8179 0.48 0.3173 0.5577 0.7818 1.0288 1.2857 1.4881 1.6189 1.7164 1.7892 1.492 1.8879 1.8637 1.8339 0.49 0.3106 0.5467 0.7612 0.9968 1.2457 1.4401 1.5650 1.6577 1.7287 1.7865 1.8236 1.8047 1.7877 0.50 0.2967 0.5231 0.7213 0.9376 1.1662 1.3438 1.4553 1.5404 1.6051 1.6587 1.6968 1.6893 1.6923 0.51 0.2855 0.5010 0.6825 0.8770 1.0831 1.2413 1.3395 1.4148 1.4752 1.5276 1.5720 1.5841 1.6113 0.52 0.2841 0.4936 0.6630 0.8410 1.0311 1.1773 1.2667 1.3382 1.3988 1.4542 1.5134 1.5507 1.5994 0.53 0.2393 0.4970 0.6596 0.8286 1.0112 1.1520 1.2388 1.3114 1.3765 1.4383 1.5165 1.5745 1.6390 0.54 0.2950 0.5023 0.6603 0.8229 1.0007 1.1402 1.2262 1.3014 1.3717 1.4398 1.5343 1.6092 1.6862 0.55 0.3012 0.5080 0.6617 0.8185 0.9924 1.1296 1.2146 1.2921 1.3671 1.4411 1.5519 1.6427 1.7341 0.56 0.3095 0.5154 0.6859 0.8485 0.9901 1.1243 1.2090 1.2891 1.3694 1.4504 1.5788 1.6893 1.7953 0.57 0.3160 0.5193 0.7145 0.8875 1.0407 1.1371 1.2001 1.2833 1.3701 1.4592 1.6084 1.7383 1.8572 0.58 0.3179 0.5388 0.7278 0.9115 1.0776 1.1858 1.2176 1.2485 1.3402 1.4359 1.6029 1.7481 1.9189 0.60 03390 0.5984 0.7291 0.8518 1.0276 1.1491 1.1955 1.2184 1.2458 1.2843 1.3994 1.6201 I.S3 0.62 0.3263 0.6221 0.7880 0.8851 0.9870 1.0563 1.0699 1.0787 1.0972 1.1340 1.2389 1.4603 1705 0.64 0.3291 0.6521 o0.8421 0.9454 1.0425 1.1060 1.1144 1.1209 1.1383 1.1723 1.2651 1.4285 1.6770 0.66 0.3224 0.6541-0.8522 0.9552 1.0622 1.189 1.1002 1.1055 1.1232 1.1559 1.2509 1.4434 1

Calc Number: GEO.HBIP.03P.02 Rev Number: 0 Sheet Number: 59 of 3 49

~D ate: 08/27/03 0.68 0.2847 0.5844 10.7680 0.9358 1.05837 11.1145 [1.1065 1.1092 1.1391 1.1699 1.2217 1.3832 1.6239 0.70 I0.2452 0.5121 0.7432 0.9265 1.0582 1.1169 1.1083 1.1264 1.1572 L.1IM 1.22811 1.3348 1.5554 0.72 jj0.2395 0.5112 0.7592 0.9543 1.0908 1.1471 1.1308 1.1380 1.1695 1.2016 I.2421 1.327i 1.5414 0.74 0.2194 0.4782 0.7170 0.8999 1.0240 1.0953 1.1007 1.1405 1.1730 1.205-7 1.2470 1.2992 1.4430 0.76 0.2096 0.4138 0.5940 0.7729 0.9232 1.0396 1.0920 1.1329 1.1665 1.1997 1.2422 ]1.2940 1.3912 0.78 10.2053 0.4063 0.5838 0.7545 0.9161 1.0355 1.0902 i1.1178 1.1523 1.1863 1.2297 J 1.2818 1.3787

-02001 0:3968' 105709--0:74298

".09047"- 1.0266 1.0878.

1.1169 1.1342 -t-1.1686- -1.2125 J-1.264-T1'

-1.3603 0.82 0.1945 0.3865 0.5568 0.7291 10.8909 1.015!

1.0826 1.1185 1.1382 11.1516 1.1933 1.2449 1.3395 0.84 0.1888 0.3758 0.5422 0.7144 0.8757 1.0020 1.0754 1.1178 1.1434 1.1609 1.1726 1.2237 1.3167 0.86 0.1830 0.3648 0.5272 0.6986 0.8590 0.9869 1.0658 1.1145 1.1458 1.1680 1.1639 1.201'2 1.2925 0.88 0.1771 0.3535 0.5118 0.6818 0.8409 0.9699 1.0536 1.1083 1.1450 1.1718 1.1746 1.1777 1.2671 0.90 0.1713 0.3422 0.4962 0.6642 0.8216 0.9514 1.0393 1.0994 1.1414 1.1726 1.1828 1.1754 1.2411 0.92 0.1657 0.3313 0.4809 0.6465 0.8020 0.9320 1.0235 1.0884 1.1353 1.1710 1.1889 1.1847 1.2203 0.94 0.1604 0.3209 0.4667 0.6293 0.7826 0.9124 1.0072 1.0765 1.1277 1.1675 1.1933 1.1933 1.2256 0.96 0.1556 0.3114 0.4539 0.6130 0.7639 0.8934 0.9908 1.0639 1.1193 1.1630 1.1966 1.2014 1.231I8 0.98 0.1512 0.3026 0.4419 0.5972 0.7456 0.8746 0.9742 1.0509 1.1101 1.1656 1.2134 1.2130 1.2385 1.00 0.1472 0.2945 0.4302 0.5816 0.7275 0.8537 0.9572 1.0370 1.1043 1.1693 1.2277 1.2371 1.2516 1.05 0.1480 0.2749 0.4018 0.5402 0.6782 0.8028 0.9070 0.9926 1.0771 1.1517 1.2328 1.2692 11.2946 1.10 0.1465 0.2635-

-0.3722 0.4915 0.61'83

-0.7361 0.839 d.77 1.0108 l.OqU.

1.2463

.1.5339

-1.3911 1.15 0.1475 0.'2651 0.3638 0.4645 0.5614 0.6573 0.7557 0.8426 0.9322 1.0379 11.2098 1.3206 1.3977 1.20 0.1507 0.2732 0.3715 0.4645-0.5521 0.6295 0.7017 0.7749 0.8517 0.9347 11.1054 1.2572 1.3694 1.25 0.1522 0.2797 0.3815 0.4718 0.5539 0.6233 0.6841 0.7406 0.7951 0.8573 1.0051 1.1519 1.3333 1.30 0.1622 0.3044 0.4227 0.5332 0.6372 0.7271 0.8058 0.8802 0.9509 1.0205 1.1562 1.3191 1.4961 1.35 0.1740 0.3270 0.4492 0.5581 0.6580 0.7403 0.8055 0.8631 0.9180 0.9781 1.1119 1.2572 1.4131 1.40 0.1737 0.3275 0.4423 0.5313 0.6295 0.7132 0.7805 0.8401 0.8965 0.9503 1.0415 1.1404 1.2500 1.45 0.1695 0.3211 0.4428 0.5403 0.6333 0.7000 0.7428 0.7897 0.8451 0.8977 0.9858 1.0769 1.1750 1.50 0.1692 0.3227 0.4470 0.5524 0.6512 0.7235 0.7708 0.8039 0.8318 0.8840 0.9705 1.0558 1.1447 1.55 0.1698 0.3262 0.4528 0.5652 0.6684 0.7451 0.7961 0.8323 0.8596 0.9007 0.9883 1.0722 1.1566 1.60 0.1665 0.3231 0.4513 0.5678 0.6734 0.7530 0.8071 0.8459 0.8754 0.9189 1.0093 1.0944 1.1771 1.65 0.1611 0.3241 0.4581 0.5619 0.6611 0.7419 0.7979 0.8387 0.8698 0.9244 1.0177 1.1043 1.1861 1.70 0.1540 0.3140 0.4497 0.5566 0.6389 0.7199 0.7772 0.8193 0.8618 0.9200 11.0148 1.1023 1.1837 1.75 0.1430 0.2951 0.4266 0.5314 0.6176 0.6985 0.7567 0.7993 0.8568 0.9156 11.0112 1.0990 1.1804 1.80o 0.1307 0.2706 0.4010 0.5158 0.6111 0.6835 0.7421 0.7933 0.8594 0.9186 1.0149 11.1034 1.18~54 1.85 0.1248 0.2614 0.3909 0.5063 0.6033 0.6728 0.7315 0.822 0.8690 0.9288 1.0261 1.1157 1.1993 1.90 0.1182 0.2492 0.3758 0.4908 0.5887 0.6602 0.760 0.8118 0.8790 0.9394 1.0377 1.1289 1.2149 1.95 0.1130 0.2345 0.3547 0.4670 0.5629 0.6525 0.7386 0.8145 10.8819 0.9425 1.0416 1.1343 1.2228 2.00 0.1058 0.2207 0.3334 0.4404 j0.5487 0.6457 0.7309 0.8062 10.8733 0.9339 1.0334 1.1270 1.2172 2.05 0.0997 0.2064 0.3177 0.4288 0.5346 0.6295 0.7130 0.7873 10.8539 0.9141 1.013,5 1.1069 1.1974 2.10 0.957 0.1983 0.3051 0.4123 0.5146 0.6065 0.6880

.0.7609 0.8267 0.8864 0.9853 1.0777 1.1672 2.15 0.0911 0.1892 0.2910 0.3936 0.4918 0.5804 0.6597 0.7312 0.7963 0.8554 0.9537 1.0443 1.1316 2.20 0.0865 0.1800 0.2769 0.3747 0.4687 0.5541 0.63 14 0.7019 0.7663 0.8248 0.9220 1.0106 1.0951 2.25 0.0821 0.1711

-0.2634 0.3567-0.4469 0.5296 0.6054 0.6749 0.7384 0.7961 10.8919 0.9783 1.0603 2.30 0.0778 0.1626 0.2508 0.3403 0.4272 0.5078 0.5822 0.6505.

0.7128 0.7695 10.8637 0.9483 1.0279 2.35 0.0736 0.1546 0.2392 0.3254 0.4096 0.4881 0.5609 0.6278 0.6890 0.7445 0.8371 0.9200 10.9977 2.40 0.0697 0.1470 0.2285 0.3118 0.3934 0.4697 0.5408 0.6061 0.6658 0.7202 0.8111 0.8926 0.9687 2.50 0.0620 0.1330 0.2088 0.2861 0.3621 0.4337 0.5006 0.5623 0.6189 0.6707 0.7585 0.8379 0.9116 2.60 0.0550 0.1198 0.1895 0.2604 0.3304 0.3966 0.4588 0.5164 0.5696 0.6189 0.7046 0.7834 0.8565 2.70 0.0517 0.1072 0.1704 0.2349 0.2988 0.3594 0.4167 0.4704 0.5207 0.5681 0.6539 0.7351 0.8104 2.180 0.0488 0.1000 0.1523 0.2107 0.2687 0.3241 0.3771 0.4276 0.4763 0.5233 0.6358 0.7435 0.8254 2.90 0.0463 0.0952 0.1440 0.1927 0.2412 0.2919 0.3415 0.3905 10.4397 0.4924 0.6279 0.7608 0.8678 3.00 0.0442 0.0910 0.1380 0.1849 0.2316 0.2769 0.3207 0.3632 10.4150 0.4836 0.6289 0.7678 10.8866 3.1-0 0.0424-0.0875 0.1330 0.1785 0.2237 0.2678 0.3107 0.354-7 0.4173 0.4844 0.6362 0.7977 0.9474 3.20 0.0407 0.83 0.1285 0.1727 0.2168 0.2599 0.3063 0.3665 0.4306 0.4985 0.6499 0.8112 0.9632 3.30 0.0390 0.0812 0.1241

0. 1672 0.2102 0.2524 0.2940 0.3441 0.4049 0.4689 0.6107 0.7623 0.9073 3.40 0.0373 0.0779 0.1195 0.1613 0.2031 0.2444 0.2853 0.3258 0.3660 0.4099 0.5342 0.6691 0.7993 3.50 0.0355 0.0743 0.1144 0.1549 0.1954 0.2355 0.2754 0.3153 0.3550 0.3946 0.4947 0.6066 0.7152 3.60 0.0334 0.0704 0.1087 0.1476 0.1866 0.2254 0.2643 0.3034 0.3425 0.3818 0.4789 0.5910 0.7002 3.70 0.0313 0.0661 0.1025 0.1396
0. 1769 0.2141 0.2519 0.2902 0.3291 0.3683 10.4599 0.5705 0.6793 3.80 0.0290 0.0615 0.0958 0.1309 0.1664 0.2020 0.2386 0.2768 0315

.54 0469 0.5455 063 3.90 0.0266 0.0568 0.0888 0.1218 0.1552 0.1893

-0.2259 0.2634 0.3008 0.3379 0.4122 0.5187 0.6252 4.00 0.246 0.0519 0.0815 0.1123 0.1439 0.1777 0.2131 0.2488 0.2845 0.3198 0.3906 0.4912 0.5937 4.10 0.0233 0.0476 10.0743 0.1032 0.1341 0.1661 0.1994 0.2332 0.2668 0.3001 0.3670 0.4615 0.5589 4.20 0.0217 0.0447 0.0677 0.0954 0.1242 0.1540 0.1851 0.2167 0.2482 0.2794 0.3421 0.4297 0.5212 4.30 10.0200 0.0413 0.0628 0.0875 0.1142 0.1418 0.1707 0.2000 0.2292 0.2583 0.3168.

0.3965 041 4.40 10.0181 _0.0378 10.0578 0.0798 0.1043 0.1297 0.1564 0.1834 0.2104 10.2373 10.2916 0.3630 0.40j

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 60 of 349 Date: 08/27/03 4.50 0.0180 0.0369 0.0568 0.0775 0.0990 0.1215 0.1456 0.1709 0.1975 J0.2254 0.2867 03545 0.4272 4.60 0.0175 0.0358 0.0551 0.0752 0.0960 0.1177 l 0.1408 0.1653 0.1909 l 0.2177 0.2766 0.3420 0.4121 4.70 0.0163 0.0333 0.0512 0.0699 0.0892 0.1094 1 0.1308 0.1533 0.1770 0.2017 0.2555 0.3145 0.3791 4.80 0.0146 0.0297 0.0457 0.0623 0.0796 0.0977 1 0.1168 0.1368 0.1579 0.1800 0.2282 0.2807 0.3366 4.90 0.0146 0.0296 0.0452 0.0613 0.0780 0.0952 ] 0.1133 0.1323 0.1522 0.1729 0.2181 0.2665 0.3151 5.00 0.0143 0.0290 0.0444 0.0604 0.0769 0.0939 0.1119 0.1307 0.1503 0.1708 0.2155 0.2640 0.3131 5.10 0:0139 0.0282 0.0432 0.0586 0.0745 0:0911J 0.1086 0.1269 ' 0.146r 0.1660

-0.2097 0.2574 0.3062 5.20 0.0135 0.0274 0.0419 0.0568 0.0721 0.080 0.1047 0.1223 0.1408 0.1600 0.2022 0.2485 0.2963 5.40 0.0123 0.0250 0.0384 0.0523 0.0665 0.0811 0.0964 0.1123 0.1290 0.1465 0.1848 0.2272 0.2718 5.60 0.0111 0.0224 0.0339 0.0464 0.0592 0.0724 0.0862 0.1005 0.1155 0.1311 0.1653 0.2035 0.2440 5.80 0.0104 0.0211 0.0316 0.0424 0.0537 0.0659 0.0787 0.0919 0.1055 0.1196 0.1492 0.1791 0.2155 6.00 0.0097 0.0198 0.0299 0.0401 0.0505 0.0616 0.0734 0.0858 0.0986 0.1118 0.1400 0.1689 0.1968 6.20 0.0091 0.0187 0.0283 0.0379 0.0478 0.0581 I 0.0691 0.0806 0.0925 0.1049 0.1315 0.1592 0.1863 6.40 0.0085 0.0175 0.0266 0.0357 0.0451 0.0548 0.0650 0.0758 0.0870 0.0985 0.1235 0.1499 0.1760 6.60 0.0085 0.0173 0.0262 0.0355 0.0449 0.0546 0.0646 0.0749 0.0855 0.0964 0.1194 0.1437 0.1688 6.80 0.0085 0.0171 0.0261 0.0352 0.0445 0.0542 0.0641 0.0744 0.0849 0.0957 0.1186 0.1429 0.1682 7.00 0.0081 0.0164 0.0250 0.0337 0.0426 0.0518 0.0613 0.0711 0.0811 0.0914 0.1133 0.1368 0.1611 7.20 0.0077 0.0155 0.0234.

..0,0314 0.0396 0.0480 0.0568 0.0658 0.0751 0.0846 0.1048 0.1265 0.1491 7.40 0.0075 0.0151 0 029 60108 0.0388 0.0470-0.0555 0.0643-0.0732 0.0822 O.100IS 0.1200

-0:14-.+

7.60 0.0071 0.0144 0.0219 0.0295 0.0371 0.0450 0.0531 0.0615 0.0701 0.0788 0.0968 0.1154 0.1345 7.80 0.0066 0.0134 0.0204 0.0276 0.0348 0.0421 0.0497 0.0576 0.0656 0.0739 0.0909 0.1085 0.1266 8.00 0.0061 0.0123 0.0188 0.0253 0.0320 0.0387 0.0457 0.0529 0.0604 0.0680 0.0838 0.1002 0.1170 8.50 0.0049 0.0098 0.0148 0.0198 0.0248 0.0297 0.0346 0.0401 0.0457 0.0515 0.0637 0.0764 0.0895 9.00 0.0041 0.0083 0.0127 0.0171 0.0215 0.0258 0.0301 0.0345 0.0389 0.0434 0.0533 0.0641 0.0757 9.50 0.0033 0.0067 0.0103 0.0139 0.0176 0.0212 0.024S 0.0285 0.0321 0.0358 0.0437 0.0525 0.0621 10.00 0.0025 0.0053 0.003 0.0114 0.0144 0.0175 0.0205 0.0237 0.0270 0.0303 0.0370 0.0433 0.0493

Calc Number: GEO.HIBIP.03.02 Rev Number: 0 Sheet Number: 61 of 349 Date: 08/27/03 -

Table 6-9b. Soil Spectra for M=7.8. Set 2. Lower Vs Soil Profile Per__

(Sec)

OG

.TR 0.203iz O.4 0.5g 0.6g 0.7-O.Rg 0.9a 1.0z, 1.2e 1.4e 1.6g 0.01 0.1289 0.2535 0.3612 0.4528 0.5261 0.5736 05.945 0.6096 0.6224 0.6263 0.6132 0.6087 0.6424 0.03 0.1324 0.2568 0.3639 04551 0.5281 0.5755 0.5962 0.6112 0.6239 0.6277 0.6145

.0.6097 0.6434 1 0.04 0.1378 f 0.2607 1 0.3667 1 0.4573.1-0-5300 1 0.5772 1 0.5978 }

0.6127 1 0.6253 1 0.6290 1 0.6156 1 0.6105 0.6442 I..- : 1~

A A-0.05 0.1392 I 0.2605 1 03691 1 0.4599 0.5325 1 0.5794 F 0.5998 F.44 0.627 1l 0.6307 1 0.6171 1 0.616 l

A 0.6452 0.06 0.1608 0.2760 0.3789 0.4670 0.5836 0.6032 0.6174 0.6296 0.6330 0.6190 0.6129 0.6466 0.07 0.1695 0.2674 0.3762 0.4654 0.5369 0.5839 0.6048 0.6197 0.6320 0.6355 0.6212 0.6144 0.6481 0.08 0.1957 0.2619 0.3716 0.4577 0.528S 0.5794 0.6035 0.6198 0.6334 0.6372 0.6234 0.6163 0.6500 0.09 0.2375 0.3215 0.4017 0.4S76 0.5591 0.6035 0.6197 0.6317 0.6422 0.6440

'0.6278 0.6180 0.6521 0.10 0.2412 0.3566 0.4463 0.5201 0.5852 0.6249 0.6376 0.6462 0.6536 0.6534 0.6335 0.6218 0.6552 0.11 0.2693 0.3737 0.4619 0.5319 0.5933 0.6313 0.6435 0.6510 0.6583 0.6581 0.6372 0.6252 0.6587 0.12 0.2920 0.3836 0.4673 0.5335 0.5919 0.6288 0.6420 0.6501 0.6577 0.6574 0.6369 0.6296 0.6628 0.13 0.3361 0.4356 0.4949 0.5407 0.5675 0.6020 0.6214 0.6326 0.6430 0.6456 0.6288 0.6319 0.6660 0.14 0.3583 0.4840 0.4909 0.5189 0.5612 0.3828 0.5875 0.6060 0.6228 0.6321 0.6251 0.6235 0.6614 0.15 0.3725 0.5210 0.5387 0.5027 0.5493 0.5763 0.5863 0.6041.

0.6215 0.6322 0.6268 0.6283 0.665S

,..--QJ16..

0.3835 0.5554.,

0.5847 0.5531.

.0.5640 0.6057 0.6131 0.6040 0.6150 0,Q,6277 0.6261 0.6169 0.6576 0.17 0.4209 0.5987 0.6414 0.6451 0.6845 0.7067 0.6S59 0.6459 0.6182 0.6252 0.6476 0.6700 0.6928 0.18 0.4143 0.6545 0.7062 0.7465 0.7850 0.8012

.0.7717 0.7227 0.6820 0.6563 0.6689 0.6919 0.7153 0.19 0.4028 0.6352 0.7875 0.8689 0.9129 0.9182 0.8909 0.8627 0.8274 0.7858 0.7232 0.7188 0.7379 0.20 0.4361 0.7108 0.8852 0.9821 1.0356 1.0458 1.0162 0.9851 0.9458 0.8975 0.8179 0.7605 0.7440 0.21 0.4359 0.7218 0.9085 1.0197 1.0861 1.1038 1.0774 1.0499.

1.0133 0.9645 0.s798 0.8158 0.7932 0.22 0.4403 0.7381 0.936S 1.0634 1.1441 1.1692 1.1453 1.1199 1.0839 1.0346 0.9423 0.8702 0.8423 0.23 0.4465 0.7575 0.9715 1.1124 1.2037 1.2369 1.2155 1.1915 1.1568 1.1063 1.0069 0.9270 0.8941 0.24 0.4479 0.7686 0.9947 1.1503 1.2536 1.2938 1.2762 1.2560 1.2228 1.1724 1.0678 0.9812 0.9434 0.25 0.4470 0.7741 1.0120 1.1799 1.2960 1.3444 1.3305 1.3126 1.2810 1.2312 1.1232 1.0314 0.9904 0.26 0.4437 0.7781 1.0261 1.2059 1.3299 1.3865 1.3767 1.3633 1.3355 1.2871 1.1756 1.0784 1.0338 0.27 0.4578 0.7805 1.0361 1.2266 1.3622 1.4259 1.4209 1.4102 1.3841 1.3367 1.2235 1.1229 1.0760 0.28 0.4663 0.7804 1.042S 1.2428 1.3882 1.4601 1.4594 1.4515 1.4295 1.3843 1.2692 1.1641 1.1153 0.29 0.4619 0.7731 1.0415 1.2504 1.4040 1.428 1.4875 1.4845 1.4645 1.4209 1.3052 1.1985 1.1479 0.30 0.4733 0.7684 1.0276 1.2434 1.4059 1.4917 1.5010 1.5006 1.4837 1.4440 1.3301 1.2211 1.1704 0.31 0.4706 0.7889 1.0096 1.2316 1.3989 1.4894 1.5031 1.5072 1.4939 1.4567 1.3449 1.2363 1.1852 0.32 0.4604 0.7968 0.9959 1.2233 1.3946 1.4899 1.5070 1.5131 1.5038 1.4704 1.3601 1.2507 1.2005 0.33 0.4624 0.8027 0.9988 1.2257 1.4017 1.5006 1.5202 1.5284 1.5215 1.4916 1.3827 1.2711 1.2209 0.34 0.4905 0.8199 1.0278 1.2369 1.4181 1.5200 1.5417 1.5529 1.5480 1.5207 1.4124 1.2990 1.2469 0.35 0.4722 0.8070 1.0519 1.2502 1.4371 1.5419 1.5658 1.5804 1.5792 1.5538 1.4446 1.3293 1.2752 0.36 0.4105 0.8004 1.0683 1.2618 1.4526 1.5615 1.5891 1.6054 1.6079 1.5857 1.4761 1.3574 1.3031 0.37 0.3977 0.8249 1.0749 1.2679 1.4632 1.5769 1.6073 1.6278 1.6325 1.6122 1.5035 1.3831 1.3262 0.38 0.3852 0.7919 1.0724 1.2760 1.4694 1.5859 1.6206 1.6437 1.6528 1.6360 1.5266 1.4035 1.3470 0.39 0.3687 0.7494 1.0637 1.3196 1.4870 1.5927 1.6300 1.6574 1.6687 1.6541 1.5454 1.4215 1.3631 0.40 0.3485 0.7238 1.0488 1.3591 1.5612 1.6368 1.6346 1.6649 1.6790 1.6683 1.5605 1.4344 1.3748 0.41 0.3357 0.6911 1.0434 1.3820 1.6089 1.7029 1.7016 1.7043 1.6937 1.6757 1.5688 1.4412 1.3815 0.42 0.3220 0.6515 1.0318 1.3811 1.6240 1.7315 1.7372 1.7454 1.7380 1.7138 1.5689 1.4395 1.3795 0.43 0.3057 0.6248 1.0045 1.3521 1.6011 1.7156 1.7269 1.7401 1.7365 1.7143 1.5733 1.4267 1.3663 0.44 0.2862 0.5988 0.9566 1.2997 1.6366 1.8398 1.8744 1.8792 1.8700 1.8430 1.6767 1.4963 1.4617 0.45 0.2632 0.5675 0.9594 1.3722 1.7506 1.9802 2.0283 2.0443 2.0415 2.0143 1.8823 1.7308 1.6910 0.46 0.2726 0.5412 0.9175 1.3442

.1.7358 1.9775 2.0397 2.0663 2.1051 2.1249 2.0258 1.S750 1.8361 0.47 0.2680 0.5163 0.8045 1.2049 1.5759 1.8498 1.9503 2.0103 2.0625 2.0885 2.0102 1.9088 1.9252 0.48 0.2938 0.5185 0.7S65 1.0829 1.4214 1.6973 1.8103 I.8983 1.9631 2.0167 2.0612 2.0421 2.0609 0.49 0.3080 0.5352 0.7786 1.0854 1.4099 1.6942 1.8412 1.9285 1.9916 2.0530 2.0976 2.0S21 2.1043 0.50 0.3069 0.5366 0.7720 1.0105 1.2998 1.5880 1.7663 1.8680 1.9575 2.0191 2.0662 2.0571 2.0852 0.51 0.3060 0.5335 0.7671 1.0032 1.2718 1.5483 1.7176 1.8142 1.9003 1.9595 2.0108 2.0109 2.0453 0.52 0.3140 0.5370 0.7583 0.9915 1.2485 1.5115 1.6736 1.7677 1.8523 1.9103 1.9676 1.9768 2.0168 0.53 0.3199 0.5519 0.7508 0.9819 1.2322 1.4863 1.6460 1.7397 1.8252 1.8838 1.9479 1.9640 2.0083 0.54 0.3225 0.5604 0.7468 0.9693 1.2152 1.4635 1.6239 17181 1.8057 1.8654 1.9349 1.9548 2.0011 0.55 0.3178 0.5571 0.7496 0.9443 1.1845 1.4271 1.5861 1.6821 1.7693 1.8306 1.9011 1.9232 1.9693 0.56 0.3164 0.5386 0.7340 0.9218 1.1367 1.3631 1.5192 1.6139 1.7007 1.7593

_1.8279 1.8479 1.9182 0.57 0.3148 0.5329 0.7237 0.8998 1.0885 1.2932 1.4218 1.5133 1.5947 1.6497 1.7103 1.7747 1.8959 0.58 0.2920 0.5110 0.6817 0.8575 1.0439 1.2187 1.3233 1.4121 1.5033 1.5665 1.6715 1.7295 1.8066 0.60 0.3272 0.5743 0.7536 0.9826 1.0431 1.2382 1.3930 1.5079 1.6182 1.7002 1.8411 1.9261 2.0249 0.62 0.3030 0.5992 0.7985 0.9415 1.0883 1.2345 t.3237 1.3700 1.4800 1.5742 1.7304 1.8257 1.9260 0.64 0.2928 0.5913 0.7985 0.9426 1.0858 1.2227 1.3047 1.3472 1.4051 1.4496 1.5620 1.6670 1.7967 0.66 0.2873 0.58S8 0.8030 0.9837 1.1512 1.2988 1.3639 1.3740 1.4168 1.4368 1.5179 1.6367 1.7795

Calc Number: GEO.BBIP.03).02 Rev Number: 0 Sheet Number: 62 of 3 49 Date:- 08/2710-3 0.68 0.2641 0.5547 0.8035 0.9833 1.1440 1.2814 1.3432 11.3399 11.3827 11.4091 11.4707 1.5359 1.63R.3 0.70 0.2441 0.5092 0.7392 0.9202 1.0995 1.2609 1.3358 11.3426 11.3505 11.3417 11.3540 1.408S7 1.5132 0.72 0.2189 0.4514 0.6734 0.8849 1.0611t 1.2301 1.3024 1.3062 I1.3144 11.3057 1 1.3179 1.3267 1.3673 0.74 0.2208 0.4563 0.6907 0.9135

1. 1075 ]1.2930 1.3680 1.3592 I1.3597 11.3441 J 1.3501 1.3577 1.4002 0.76 0.2195 0.4557 0.6944 0.9152 1.1176 1.3039 1.3828 1.3695 1.3539 1.3318 1.3403 1.3548 1.4057 0.78 0.2082 0.4309 0.6565 0.8671 1.0734 11.2618 1.3511 1.3461 1.3403 1.3706 J1.3939 11.3652 11.3561 0.80 1i'2'03 0.4229 -

0:6-488", 0.8662 1.0820.- 1.2808 1.3791 11.3-744.-l 1.3795 1.4138.1.1.4A455..j 1.4241-.I-14228 0.82 0.1937 0.4044 0.6252 0.8426 1.0609 1.2608 1.3602 1.3529 1.4027 1.4406 1.4769 1.4599 11.4624 0.84 0.1773 0.3592 0.5611 0.7548 0.9618 1.1i447 1.2872 1.3969 1.4742 1.5091 j1.5432 1.5255 J 1.5300 0.86 0.1836 0.3551 0.5456 0.7558 0.9667 1.1734 1.3406 1.4452 1.5165 1.5471 [1.5831 1.5722 J1I.5s42 0.88 0.1783 0.3465 0.5271 0.7270 -0.

9 288 1.1254 1.2790 1.3704 1.4355 1.4683 1.5194 1.5252 j 1.5483 0.90 0.1675 0.3245 10.4880 0.6680 0.8493 1.0246 1.1600 1.2445 1.3134 1.3587 1.4313 1.4512 1.4793 0.92 0.1657 0.3200 0.4777 0.6494 0.822S 0.9912 1.1265 1.2226 1.3072 1.3665 1.4484 1.4657 1.4900 0.94 0.1712 0.3318 0.4940 0.6699 0.8489 1.0259 1.1752 1.2875 1.3 837 1.4457 1.5197 1.5272 1.54-73 0.96 0.1704 0.3327 0.4948 0.6697 0.8494 1.0293 1.1844 1.3005 1.3953 11.4511 11.5141 11.5201 1.5430 0.98 0.1606 0.3150 0.4679 0.6314 0.8000 0.9697 1.1164 1.2245 1.3100 1.3587 1.4187 1.4353 1.4661 1.00 0.1506 0.2955 0.4416 0.6000 0.7498 0.8986 1.0333 1.1512 1.2635 1.3351 1.3778 1.3684 1.3980 1.05 0.1453 0.2860 0.4216 0.5621 0.7063 0.8528 0.9847 1.0891 1.1839 1.2552 1.370-7 1.3786 11.4149 1.10

-0.1455 0.2626 0.3782' 0.5018 0.6282"-0 9t 0.8820 1~.0129-!

1.1216 1.1988 1.3102 1.3816 124057 1.15 0.1592 0.2889 0.4046.0.5142 0.6273 0.7515 0.8883 11.0228 1.1412 1.2334 1.3693 1.4324 1.4675 1.20 0.1730 0.3244 0.4575 0.5675 0.6587 0.7335

.0.8060 10.9052 1.0190 1.1139

'1.2593 1.3251 1.4466 1.25 0.1760 0.3333 0.4750 0.5966 0.6990 0.7823 0.8453 10.9017 0.9599 1.0165 1.1615 11.3207 1.4688 1.30 0.1718 0.3214 0.4613 0.5841 0.6889 10.7744 0.8366 10.8877 0.9382 0.9866 1.1146 1.2741 1.4271 1.35 0.1743 0.3279 0.4581 0.5643 0.6629 0.7474 0.8071 0.8526 0.8954 0.9354 1.0540 1.2031 1.3493 1.40 0.1742 0.3299 10.4633 0.5723 0.6635 0.7361 0.7849 0.8226 0.634 0.9085 1.0341 1.1749 1.3171 1.45 0.1709 0.3261 0.4599 0.5692 0.6597 0.7310 0.7770 0.8096 10.8440 0.8812 10.9945 1.1267 1.2638 1.50 0.1638 0.3147 0.4459 0.5531 0.6405 0.7079 0.7494 0.7981 10.8553 0.8981 10.9764 1.0956 1.2509 1.55 0.1545 0.3109 0.4562 0.5798 0.6808 0.7574 0.8038 0.8329 0.8612 0.9015 0.9945 11.0884 1.2103 1.60 0.1521 0.3066 0.4502 0.5733 0.6741 0.7503 0.7963 0.8238 0.8489 0.8711 0.9410 1.0210 1.1 158 1.65.

0.1522 0.3066 0.4501 0.5729 0.6732 0.7487 0.7937 10.8210 0.8417 0.8575 0.9225 1.0046 1.1035 1.70 0.1435 0.2891 0.4234 0.5491 0.6655 0.7606 0.8223 10.8570 0.8762 10.8830 0.9179 0.9770 1.0600 1.75 0.1275 0.2610 10.3964 0.5235 0.6381 0.7334 0.7951 0.8276 0.8431 1 0.8452 0.8722 0.9255 1.0032 1.80 0.1268 0.2655

. 0.4068 0.5411 0.6623

.0.7627 0.8263 0.8565 0.8670 10.8625 0.8793 0.92'71 1.0027 1.85 0.1334 0.2807 0.43 14 0.5737 0.6997 0.8023 0.8643 0.8888 0.9056 0.9035 0.8998 10.9200 0.9940 1.90 0.1285 0.2714 0.4171 0.5526 0.6702 0.7633 0.8382 0.8880 0.9118 0.9315 0.9468 10.9628 1.0106 1.95 0.1160 0.2458 0.3781 0.5003 0.6206 10.7281 0.8225 0.8999 0.9479 0.9671 0.9799 0.9925 1.044 2.00 0.1048 0.2243 0.3521 0.4902 0.6270 10.7567 0.8654 0.9435 0.9896 1.0052 1.0558 1.1113 1.183 2.05 0.1012 0.2220 0.3560 0.4957 0.6327 0.7605 0.636 10.9335 0.9722 1.0036 1.0669 1.1327 11.2151 2.10 0.0913 0.1995 0.3188 0.4416 0.5601 0.6680 0.7514 10.8330 0.9087 0.9592 1.0152 1.0399 11.1255 2.15 0.0884 0.1854 0.2896 0.3994 0.5112 0.623 8 0.7322 10.8289 10.9052 0.9565 1.0130 1.0565 11.1337 2.20 0.0861 0.1817 0.2843 0.3922 0.5022 0.6132 0.7201 1_0.8159 10.89 17 0.9430 11.0136 1.0791 11.1601 2.25 0.0827 0.1758 0.2758 0.3808 0.4879 0.5962 0.7004 0.8132 0.9106 0.9811 1.0648 1.1172 1.1843 2.30 0.0785 0.1677 0.2641 0.3652 0.4684 0.5728 0.6795 0.7897 0.8807 0.9465 1.0269 1.1006.

1.1871 2.35 0.0735 0.1578 0.2495 0.3457 0.4441 0.5437 0.6400 0.7271 0.064 0.8738 1.0033 1.1005 1.1889 2.40 0.0678 0.1462 0.2323 0.3229 0.4156 0.5100 0.6058 0.7023 0.7903 0.8677 0.9954 1.0940 1.1836 2.50 0.0627 0.1344 0.2145 0.3006 0.3903 0.4841 0.5804 0.6744 10.7605 0.8369 10.9638 1.0632 11.1540 2.60 0.0576 0.1239.

0.1981 0.2786 0.3626 0.4509 0.5423 0.6325 0.7155 0.7898 10.9138 1.0122 11.1020 2.70 0.0515 0.1112 0.1783 0.2517 0.3287 0.4104 0.4957 0.5807 0.6594 0.7304 10.8683 0.9936 1.0988 2.80 0.0453 0.0977 0.1571 0.2225 0.2917 0.3658 0.4440 0.5227 0.5961 0.6629 10.7760 0.8777 0.9986 2.90 0.0427 0.0900 0.1431 0.2003 0.2603 0.3242 0.3913 0.4618 0.5321 0.6135 10.7801 10.9329 1.0577 3.00 0.0400 0.0842 0.1334 0.1868 0.2428 0.302-5 0.3656 10.4300 0.5032 0.5802 107366 10.8844 1.0116 3.10 0.0393.

0.0812 0.1251 0.1732 0.2252 0.2806 0.3397 0.4006 0.4647 0.5388 0.6997 0.8602 1.0085 3.20 0.0362 0.0756 0.1175 0.1614 0.2076 0.2590 0.3144 0.3736 0.4344 0.4961 0.6267 0.7687 10.8978 3.30 0.0324 0.0671 0.1053 0.1473 0.1925 0.2415 0.2952 0.3527 0.4109 0.4700 0.5822 0.6853 10.7804 3.40 0.0314 0.0659 10.1028 0.1418 0.1821 0.2278 0.2784 0.3325 0.3875 0.4434 0.5499 0.6537 10.7713 3.50 0.0293 0.06271 0.0979 0.1360 0.1759 0.2183 0.2637 0.3122 0.3638 0.4164 0.5169 0.6343 0.7537 3.60 0.0272 0.0563 0.0879 0.1224 0.1596 0.2002 0.2445 0.2918 0.3401 0.3893 0.4837 0.5712 0.6821 3.70 0.0257 0.0529 0.0819 0.1140 0.1486 0.1864 0.2277 0.2717 0.3167 0.3626 10.4508 0.5328 0.308 3.80 0.0264 0.0545 0.0842 0.1154 0.1476 0.1809 0.2155 0.2520 0.2960 0.3434 0.4393 0.5352 J0.6289 3.90 0.0272 0.0563 0.0873 0.1201 0.1541 0.1896 0.2268 0.2653 10.3041 0.3440 0.4338 0.5388 j0.6418 4.00 0.0265 0.0552 0.0858 0.1186 0.1530 0.1892 0.2275 0.2673 0.3078 0.3499 0.4360 0.5238 0.6246 4.10 0.0240 0.0501 0.0782 0.1084 0.1406 0.174.9 0.2115 0.2497 0.2887 0.3294 0.4131 0.4986 0.5832 4.20 0.0204 0.0430 0.0672 0.0934 0.1216 0.1519 0.1845

-0.2186 0.2535 0.2900 0.3652 0.4417 0.5170 4.30 0.019 0.0409 0.0633 0.0870 0.181017 0.1657 0.1945 0.2238 0.2538 0.3169 0.3884 0.4653 4.40 0.018 0.0386 0.0598 10.0822 0.091011 0.1581 0.1868 0.2161 0.2464 30.391 10.3-784 0.452.5

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 63 of 349 Date: 08/27/03 4.50 0.0174 1 0.0355 0.0542 0.0743_

0.0958 0.1 188 0.1439 0.1708 1 0.1987 I 0.2278 0.2877 I0.3527 0.4215 4.60 0.0167 0.0340 0.0518 0.0703 0.0892 0.1096 0.1334 0.1582 j 0.1835 10.2098 0.2639 0.3219 0.3853 4.70 0.0181 0.0371 0.0567 0.0767 0.0969 0.1173 0.1378 0.1580 0.1782 0.2044 0.2614 j 0.3216 0.3802 4.80 0.0186 0.0384 0.0590 0.0803 0.1019 0.1240 0.1466 0.1693 0.1913 0.2126 0.2589 l 0.3219 023835 4.90 0.0179 0.0373 0.0577 0.0790 0.100I 0.1234 0.1467 0.1705 0.1940 0.2171 0.2624 l 0.3087 0.3642 5.00 0.0164 0.0345 0.0537 0.0740 0.0949 0.1167 0.1396 0.1631 0.1866 0.2099 0.2559 0.3024 0.3495 5.10 0.0148L, -0.0312 0.0489-0-00676-0.0871 0.1076.

43.1292

.0.1516 A.0.174L-.

0.1967 0.2412.

Q.2860 0.3310.

3.20 0.0135 0.0285 0.0448 0.0622 0.0803 0.0994 0.1198 0.1410 0.1624 L0.1839 0.2263 0.2690 0.3117 5.40 0.0121 0.0255 0.0402 0.0560 0.0726 0.0902 0.1091 0.1290 0.1492 0.1698 0.2107 0.2518 0.2929 5.60 0.0112 0.0220 0.0347 0.0486 0.0635 0.0794 0.0969 0.1156 0.1349 0.1550 0.1955 0.2368 0.2730 5.80 0.0116 0.0233 0.0355 0.0485.

0.0619 0.0756 0.0894 0.1032 0.1171 0.1315 0.1618 0.1939 0.2313 6.00 0.0119 0.0239 0.0364 0.0498 0.0637 0.0782 0.0930 0.1078 0.1229 0.1385 0.1713 0.2057 0.2402 6.20 0.0108 0.0215 0.0320 0.0438 0.0562 0.0695 0.0833 0.0974 0.1116 0.1265 0.1577 0.1908 0.2242 6.40 0.0106 0.0214 0.0321 0.0424 0.0525 0.0625 0.0726 0.0832 0.0945 0.1064 0.1308 0.1556 0.1810 6.60 0.0090 0.0184 0.0278 0.0370 0.0463 0.0565 0.0671 f0.0778 0.0885 0.0994 0.1222 0.1467 0.1712 6.80 0.0080 0.0165 0.0252 0.0341 0.0430 0.0519 0.0618 0.0718 0.0818 0.0919 0.1134 0.1364 0.1595 7.00 0.0079 0.0161 0.0245 0.0333 0.0423 0.0516 0.0609 0.0705 0.0816 0.0936 0.1184 0.1434 0.1680 7.20 0.0078 0.0158 0.0239 0.0321 0.0404 0.0488 0.0573 0.0661 0.0751 0.0841 0.1073 0.1317 0.1558

-7.40 0.00753 -§0.0 52 0.0231 0.0311-0.0392 0.0475 0.0561 0.0647 0;0732

-0.0814 0.0976.

OC,1+7.1 0.1362 7.60 0.0072 0.0144 0.0217 0.0290 0.0361 0.0431 0.0498 0.0563 0.0632 0.0706 0.0882 0.1074 0.1257 7.80 0.0068 0.0137 0.0207 0.0276 0.0345 0.0413 0.0478 0.0542 0.0606 0.0672 0.0822 0.0994 0.1176 8.00 0.0062 0.0126 0.0192 0.025S 0.0323 0.0387 0.0449 0.0509 0.0570 0.0632 0.0771 0.0929 0.1098 8.50 0.0050 0.0099 0.0151 0.0205 0.0259 0.0315 0.0371 0.0425 0.0478 0.0537 0.0661 0.0789 0.09176 9.00 0.0050 0.0100 0.0152 0.0207 0.0264 0.0322 0.0383 0.0447 0.0511 0.0575 0.0700 0.0823 0.09475 9.50 0.0050 0.0102 0.0154 0.0208 0.0262 0.0316 0.0373 0.0430 0.0485 0.0540 0.0646 0.0753 0._623 10.00

' 0.0042 0.0086 0.0132 0.0178 0.0225 0.0274 0.0324

. 0.0375 0.0426 0.0477 0.0576 0.0677 0.07801

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 64 of 349 Date: 08/27/03 Table 6-9c. Soil Spectra for M=7.8, Set 3, Lower Vs Soil Profile Per (sec) 0.1g 0.2g 0.3g 0.4g O

~ ~ 0.6e [ 0.7.

08s 0.9g 1.01Z 1.2g 1.4a 1.6',

0.01 0.1462 0.2390 0.3266 0.4085 0.4869 0.5324 I0.5525 0.3627 0.5721 0.5834 0.5953 0.6190 0.6592 0.03 0.1486 0.2412 0.3277 0.4107 0.4881 0.5338 10.5539 0.5639 0.5733 0.5847 0.5965 0.6202 0.6604 0.04 0.1503 0.2425 P.28 0.4123 0.4891 0.5350 0.5550 0.5651 0.5744 0.5857 0.5975 0.6212 0.6615 0.05 0.1540 0.2400' 6-3310 0.4151 0.4906' 0.5366 0.5567 0O.5666 0.5757.:6.587G 0.5987 0.6225~ '-062 0.06 0.1594 0.2682 0.3366 0.4145 0.4925 0.5386 0.5586 0.5683 0.5773 0.5887 0.6003 0.6241 0.6645 0.07 0.1633 0.2515 0.3384 0.4237 0.4950 0.5415 0.5611 0.5706 0.5795 0.5907 0.6023 0.6260 0.6665 0.08 0.1759 0.2900 0.3466 0.4077 0.4904 0.5400 0.5612 0.5716 0.5810 0.5926 0.6044 0.6281 0.6687 0.09 0.2054 0.2866 0.3645 0.4216 0.5081 0.5532 0.5711 0.5788 0.80 0.5964 0.01 0635 061 0.10 0.2536 0.3260 0.4073 0.4572 0.5129 0.5555 0.5696 0.5752 0.5810 0.5917 0.6053 0.6308 0.6728 0.11 0.2634 0.3584 0.4436 0.4922 0.5154 0.5543 0.5710 0.5784 0.5855 0.5964 0.6091 0.6340 0.6760 0.12 0.2809 0.3940 0.4864 0.5385 0.5611 0.5562 0.5595 0.5656 0.5713 0.5838 0.6038 0.6324 0.6762 0.13 0.2899 0.4227 0.5177 0.5725 0.6006 0.5966 0.5806 0.5825 0.5927 0.6049 0.6167 10.6414 0.6825 0.14 0.3155 0.5166 0.5903 0.5944 0.5870 0.5846 0.5864 0.5947 0.6062 0.6189 0.6297 0.6528 0.6931 0.15 0.3264 0.5275 0.6103 0.6264 0.6265 0.6257 0.6065 0.5934 0.5946 0.5961 0.6157 0.6442 0.6897 0.16 0.77 057 066

.42 0.6558 064 0.3 0-06141 0.6203 0.6279 0.6338 0.6557 0.6950 0.17 0.3901 0.5666

'0.5989 0.6647 0.6959 0.7093 0.7067" 0.7013 0.6984 b0.6987 0.6882

.0T6-82..0.7262 0.18 0.3963 0.5951 0.7012 0.7656 0.7994 0.81 17 0.8054 0.7948 0.7844

.0.7776 0.7521 0.7512 0.7700 0.19 0.3912 0.6047 0.7436 0.8362 0.8817 10.8773 0.8466 0.8187 0.8047-0.7915 10.7656 0.7646 0.7849 0.20 0.4014 0.6146 0.7603 0.8607 0.9201 0.9194 0.8885 0.8610 10.8450 0.8279 0.7691 0.7326 0.7638 0.21 0.3997 0.6154 0.8049 0.9035 0.9722 0.9761 0.9442 0.9132 0.8961 0.8774 0.8137 0.7695 0.7661 0.22 0.3987 0.6480 0.7881 0.9171 0.9908 1.0013 0.9727 0.9419 0.9217 0.9039 0.8410 0.8204 0.8383 0.23 0.4038 0.6867 0.8247 0.9533 1.0547 1.0815 1.0508 1.0208 1.0008 0.9791 0.9083 0.8947 0.9001 0.24 0.4020 0.6415 0.8585 0.9623 1.0443 1.0948 1.0971 1.0785 1.0533 1.0346 0.9813 0.9555 0.9500 0.25 0.4245 0.6725 0.8798 1.0193 1.0791 1.1341 1.1362 1.1154 1.0848 1.0636 1.0043 0.9719 0.9599 0.26 0.4669 0.6774 0.8349 0.9599 1.0731 1.1293 1.1317 1.1112 1.0771 1.0533 0.9902 0.9539 0.9384 0.27 0.4980 0.7288 0.9074 1.0126 1.0568 1.0499 1.0125 0.9941 0.9833 0.9850 0.9656 1.0020 0.9885 0.28 0.5447 0.8291 0.9163 0.9630 1.0218 1.0914 1.0963 1.0768 1.0692 1.0825 1.1149 1.1506 1.1336 0.29 0.5324 0.8238 0.9385 0.9878 1.0492 1.1120 1.1156 1.0982 1.0921 1.1061 1.1380 1.1800 1.1732 0.30 0.4990 0.8554 0.9613 1.0137 1.0567 1.0791 1.0861 1.0715 1.0654 1.0789 1.1143 1.1634 1.1703 0.31 0.5040 0.8868 1.0113 1.0521 1.0716 1.1020 1.1076 1.0992 1.1130 1.1234 1.0754 1.0857 1.1096 0.32 0.4749 0.8255 1.0194 1L084 1.1194 1.1256 1.1362 1.1415 1.1731 1.1840 1.1401 1.1040 1.0210 0.33 0.4753 0.8055 1.0048 1.1504 1.1862 1.1504 1.1165 1.1288 1.1595 1.1745 1.1410 1.1111 1.0503 0.34 0.4994 0.8398 1.0831 1.2464 1.3035 1.2813 1.2279 1.1941 1.2141 1.2155 1.1802 1.1533 1.0935 0.35 0.5250 0.8700 1.1151 1.3111 1.3969 1.3887 1.3398 1.3076 1.3297 1.3337 1.2518 1.2114 1.1281 0.36 0.4775 0.8429 1.1305 1.3401

.1.4493 1.4519 1.4065 1.3776 1.4029 1.4116 1.3337 1.2948 1.2102 0.37 0.4340 0.8482 1.1497 1.3571 1.4837 1.4897 1.4307 1.3819 1.3898 1.4040 1.3435 1.3106 1.3223 0.38 0.4007 0.8760 1.2446 1.4283 1.5730 1.5889 1.5404 1.4995 1.5161 1.5209 1.4441 1.4009 1.3403 0.39 0.3958 0.8813 1.2765 1.4123 1.5237 1.5540 1.5208 1.4940 1.5166 1.5251 1.4482 1.4023 1.3293 0.40 0.3650 0.8353 1.2302-1.5129 1.6309 1.6571 1.6044 1.5578 1.5659 1.5609 1.4756 1.4535 1.4070 0.41 0.3257 0.7402 11.1976 1.4709 1.6435 1.7029 1.6921 1.6712 1.6819 1.6693 1.5241 1.4634 1.4087 0.42 0.2992 0.6801 1.1230 1.5278 1.7484 1.8213 1.8199 1.8051 1.8201 1.8091 1.6529 1.5586 1.5001 0.43 0.2757 0.6424 1.1035 1.5389 1.7774 1.8605 1.8672 1.8567 1.8735 1.8623 1.7012 1.5998 1.5401 0.44 0.2779 0.5832 0.9787 1.3989 1.6302 1.7124 1.7220 1.7143 1.7266 1.7141 1.5802 1.5245 1.5099 0.45 0.2935 0.5119 0.8281 1.1852 1.4229 1.5033 1.5707 11.6071 1.6549 1.6868 1.6406 1.6281 1.6246 0.46 0.3004 0.5135 0.7933 1.0766 1.3572 1.5351 1.6316 1.6862 1.7475 1.7872 1.7515 1.6991 1.6443 0.47 0.2852 0.5074 0.7987 1.1032 1.3927 1.6056 1.7135 1.7773 1.8476 1.8935 1.8608 1.8096 1.6959 0.48 0.2806 0.4817 0.7747 1.0922 1.3970 1.6222 1.7410 1.8136 1.8904 1.9417 1.9168 1.8715 1.7598 0.49 0.2879 0.4970 0.7213 1.0286 1.3347 1.565-2 1.6922 1.7711 1.8533 1.9106 1L8967 1.8735 1.8391 0.50 0.2848 0.4923 0.7198 1.0063 1.2652 1.4528 1.5882 1.6826 1.7688 1.8425 1.8863 1.9009 1.8941 0.51 0.2815 0.4743 0.6892 0.9740 1.2397 1.4307 1.5465 1.6411 1.7277 1.8024 1.8604 1.9130 1.9230 0.52 0.2810 0.4864 0.6522 0.8861 1.1382 11.3379 1.469 1.5632 1.6490 1.7237 1.7765 1.8025 1.8126 0.53 0.2928 0.5111 0.6682 0.8201 1.0434 1.2414 1.3692 1.4610 1.5451 1.6188 1.6750 1.7234 1.I818 0.54 0.3037 0.5236 0.7086 0.8883 1.0632 1.1844 1.2667 1.3580 1.4526 1.5559 1.7073 1.8369 1.9729 0.55 0.3117 0.5299 0.7221 0.9083 1.0963 1.2310 1.3198 1.4122 1.5078 1.6108 1.7589 1.8842 2.0146 0.56 0.3304 0.5664 0.7361 0.8888 1.0777 1.2159 1.3047 1.3942 1.4862 1.5850 1.7265 1.8444 1.9678 0.57 0.3345 0.5771 0.7589 0.8892 1.0285 1.1632 1.2489 1.3328 1.4191 1.5121 1.6445 1.7766 1.9595 0.58 0.3411 0.5705 0.7559 0.8947 1.0089 1.1076 1.1834 1.2576 1.3417 1.4426 1.6110 1.7716 1.9625 0.60 0.3185 0.5367 0.75 0.85461 0.9717 1.0673 1.1383 1.2048 1.2797 1.3789 1.5438 1.6987 1.8788 0.62 0.2877 0.5443 0.75 0.8415 0.9095 1.0269 11.1029 1.1651 1.2154 1.2798 1.3861 11.5063 1.6840 I.

A I

U.01+

0.2928 1 0.5828

{ 0.7894 1 0.9308 1.0281 1 1.1069 1 1.1130 1.1743 1 1.2265 1 1.2886 1.3851 1 1.4I55 1.bSL"Y I I

066

.2 14 I

.560 0.75 I

.936

.095 1178 I1.265 1.181 1.129 I 1237 I1.253 I

.416

. I4 10.66 0.2814 1 0.5680 1 0.7758 1o 0.9336 1.0795 1 1.1781 1 1.2065 1.1981 1 1.1X29 1 1.2347 1 1.3253 1 1.4156 1.5704 I

Calc Number: GEO.BBIP.03.02 Rev Number: 0 Sheet Number: 65 of' 349

___D ate: 08/27/03 0.68 I0.2456 0.500-2 10.6990 0.8650 1.0151 1.1264 1.1743 1.1840 1.1682 1.1510 11.1888 1.2652 1.3929 10.701 0.2208 0.4587 0.6844 0.9088 1.0646

1. 1377 1.1339 1.1198 1.1125 1.1221 1.1580 I1.2626 1.4234 0.72 j0.2241 0.4615 0.7227 0.9485 1.1107 1.1927 1.1954 1.1865 1.1831 1.2003 1.2178 1.2454 1.4076 0.74 I0.2148 0.4465 0.6869 0.8995 1.0592 1.1451 1.1538 1.1487 1.1474 1.1674 1.1975 1.2379 1.3185 0.76 0.2077

.0.4311 0.6582 0.8630 1.0187 1.1031 1.1501 1.1698 1.1580 1.1391 1.1580 1.2064 1.2940 0.78 0.1956 0.4075 0.6192 0.8105 1.0084 1.1627 1.2335 1.2526 1.2402 1.2218 1.1483 1.1668 1.2353 0.80 0.1903, 0.4017 0.6104~

0.8348 1.0470 1L2044--

1.2767 11.2972'

.1.2867-1.2709 1;2014 1.2196 1.2745 0.82 0.1841 0.3954 0.6073 0.8330 1.0457 1.2045 1.2789 1.3025 1.2953 1.2826 1.2286 1.2470 1.3014 0.84 0.1733 0.3789 0.5887 0.8116 1.0229 1.1826 1.2595 1.2862 1.2819 1.2720 1.2432 1.2618 1.3146 0.86 0.1586 0.3540 0.5581 0.7749 0.9820 1.1403 1.2184 1.2472 1.2456 1.2388 1.2429 1.2631I 1.3139 0.88 0.1527 0.3194 0.5119 0.7171 0.9143 1.0670, 1.1442 1.1748 1.1768 1.1741 1.2123 1.2368 1.2865 0.90 0.1486 0.2869 0.4569 0.6459 0.8287 10.9724 1.0477 1.0815 1.0887 1.1035 1.1575 1.1881 1.2369 0.92 0.1427 0.2707 0.4070 0.5804 0.7494 0.8846 0.9601 0.9987 1.0434 1.0852 1.1076 1.1442 1.1917 0.94 0.1468 0.2779 0.4009 0.5312 0.6906 0.8215 0.9363 1.0566 1.1359 1.1817 11.1673 1.1249 1.1703 0.96 0.1547 0.2960 0.4300 0.5672 0.7067 0.8519 0.9963 1.1181 1.2003 1.2502 1.2402 1.1821 1.1719 0.98 0.1594 0.3070 0.4470 0.5916 0.7387 0.8872 1.0309 1.1540 1.2390 1.2926 1.2871 1.2285 1.2075 1.00 0.1616 0.3119 0.4544 0.6008 0.7503 0.8991 1.0410 1.1646 1.2517 1.3082 1.3073 1.2473 1.2245 1.05 0.1595 0.2998 0.4271 0.5614 0.6963 0.8291 0.9548 1.0686 1.1526 1.2260 1.2851 11.2918 1.3023 1.10 0.1660 0:.3160 0.4427' 0.5k77t1 0.6941 10.7870-0.8565 0:9205 0.9906 1.0722

-1.1649 -1.2441 1.33i3 AF-.

1.15 0.1662 0.3 178 0.4641 0.6074 0.7354 10.8393 0.9178 0.9985 1.0552 1.1194 1.2270 1.3193 1.4112 1.20 0.1626 0.3143 10.4604 0.6051 0.7369 10.8454 0.9278 1.0003 1.0668 1.1299 1.233-2 1.3219 T.4144 1.25 0.1558 0.3036 0.4455 0.5866 0.7169 0.8249 0.9069 0.9780 1.0419 1.1019 1.1991 1.2843 1.3765 1.30 0.1512 0.2958 0.4344 0.5717 0.6998 0.8069 0.8882 0.9583 1.0203 1.0783 1.1727 1.2684 1.4049 1.35 0.1598 0.2869 0.4193 0.5519 0.6766 0.7818 0.8621 0.9309 0.9910 1.0470 1.1384 1.2217 1.3473 1.40 0.1604 0.2936 0.4024 0.5301 0.6505 0.7525 0.8303 0.8965 0.9538 1.0068 1.0934 1.1733 1.2622 1.45 0.1595 0.3084 0.4361 0.5410 0.6418 0.7418 0.8179 0.8823 0.9377 0.9888 1.0727 1.1518 1.2405 1.50 0.1471 0.2879 0.4087 0.5288 0.6460 0.7457 0.8218 0.8863 0.9418 0.9928 1.0781 1.1605 1.2528 1.55 0.1370 0.2722 0.3998 0.5229 0.6382 10.7371 0.8134 0.8782 0.9341 0.9855 1.0725 1.1583 1.2532 1.60 0.1381 0.2794 10.4070 0.5132 0.6098 0.7063 0.7817 0.8457 0.9010 0.9515 1.0378 1.1236

-1.2172 1.65 0.1421 0.2879 10.4208 0.5324 0.6173 0.6708 0.7447 0.8070 10.8608 0.9093 0.99-24 1.0756 1.1654 1.70 0.13-70 0.2-787 0.4102 0.5224 0.6089 0.6696 0.7277 0.7885 0.8407 0.8875 0.9671 1.0478 1.1345 1.75 0.1329 0.2719 0.4036 0.5216 0.6212 0.6905 0.7378 0.7982 0.8497 0.8956 0.9737 1.0544 1.1414 1.80 0.1329 0.2721 0.4072 0.5300 0.6315 0.7021 0.7606 0.8211 0.8727 0.9187 0.9972 1.0806 1.1710 1.85 0.1241 0.2545 0.3805 0.4947 0.6062 0.7027 0.7759 0.8362 0.8880 0.9342 1.0144 1.1019 1.1973 1.90 0.1160 0.2415 0.3687 0.4925 0.6051 0.6996 0.7711 0.8308 0.8827 0.9295 11.0130 1.1057 1.2066 1.95 0.1121 0.2336 0.3571 0.4768 0.5902 0.6959 0.7727 0.8288 0.8701 0.9106 10.9995 1.0965 1.2009 2.00 0.1053 0.2193 0.3354 0.4598 0.5822 0.6871 0.7648 0.8239 0.8696 0.9057 10.9804 1.0773 1.1819 2.05 0.1013 0.2142 0.3384 0.4627 0.5749 0.6717 0.7451

-0.7995 0.8513 0.8951 0.9591 1.0500 1.1525 2.10 0.0942 0.2011 0.3177 0.4409 0.5601 0.6607 0.7259~ 0.7722 0.8323 0.8838 0.9619 1.0303 1.1194 2.15 0.0849 0.1815 0.2871 0.3975 0.5026 0.5889 0.6778 0.7677 0.8389 0,8937 0.9611 1.0379 1.1106 2.20 0.0800 0.1690 0.2643 0.3628 0.4618 0.5814 0.6913 0.7825 0.8555 0.9123 0.9819 1.0412 1.1210 2.25 0.0753 0.1599 0.2514 0.3472 0.4598 10.5810 0.6894 0.7799 0.8528 0.9106 0.9855 1.0420 1.1295 2.30 0.0706 0.1509 10.2390 0.3349 0.4514 10.5689 0.673?

0.7620 0.8344 10.8934 0.9768 1.0425 1.1379 2.35 0.0659 0.1420 0.2273 0.3231 0.4340 0.5458 0.6460 0.7320 0.8055 0.8679 0.9604 1.0427 1.1439 2.40 0.0613 0.1337 0.2155 0.3048 0.4087 0.5 138 0.6103 0.6967 0.7727 0.8372 0.9347 1.0374 11.1413 2.50 0.0536 0.1178 0.1903 0.2682 0.3492 0.4448 0.5368 0.6197 0.6957 0.7671 0.8883 0.9966 1.1006 2.60 0.0561 0.1202 0.1915 0.2707 0.3573 0.4505 0.5469 0.6436 0.7379 0.8254 0.9684 1.0682 1.1405 2.70 0.0493 0.1057 0.1716 0.2466 0.3297 0.4211 0.5174 0.6138 0.7075 0.7940 0.9373 1.0537 1.1421 2.80 0.0445 0.0963 0.1552 0.2213 0.2945 10.3755 0.4619 0.5508 0.6410 0.7286 10.8854 1.0037 1.0899 2.90 0.0395 0.0821 0.1303 0.1869 0.2514 0.3 222 0.3943 0.4698 0.5507 0.6283 10.7741 0.9104 1.0222 3.00 0.0384 0.0790 0.1241

0. 1772 0.2380 0.3051 0.3746 0.4426 0.5082 0.5706 0.7182 0.8449 0.9485 3.10 0.0376 0.0772 0.1193 0.1667 0.2225 0.2857 0.3528 0.4195 0.4843 0.5458 0.6606 0.7654 10.8649 3.20 0.0356 0.0733 0.1134 0.1575 0.2078 0.2656 0.3284 0.3915 0.4529 0.5113 0.6198 0.7185 10.8213 3.30 0.0328 0.0677 0.1050 0.1464 0.1925 0.2437 0.3008 0.3586 0.4150 0.4687 0.5696 0.6875 10.8031 3.40 0.0339 0.0693 0.1077 0.1508 0.1983 0.2493 0.3021 0.3552 0.4086 0.4618 0.5788 0.7032 0.8264 3.50 0.0334 0.0686 10.1066 0.1492 0.1964 10.2477 0.3013 0.3556 0.4106 0.4655 0.5781 0.6921 0.8157 3.60 0.0290 0.0601 0.0939 0.1316 0.1737 10.2199 0.2687 0.3183 0.3686 0.4191 0.5228 0.6280 0.7356 3.70 0.0246 0.0521 0.0825 0.1155 0.1502 0.18653 0.2259 0.2686 0.3119 10.3555 0.4466 0.3397 0.6340 3.80 0.0226 0.0480 0.0762 0.1070 0.1395 0.1733 0.2078 0.2429 0.2790 0.3158 0.3973 0.4830 0.5693 3.90 0.0219 0.0465 Q.0741 0.1043 0.1364 0.1701 0.2047 0.2402 0.2767 0.3139 0.3923 0.4736 0.5575 4.00 0.0212 0.0433 0.0693 0.0983 0.1295 0.1628 0.1976 0.2336 0.2708 0.3091 0.3904 0.4745 0.5610 4.10 0.0202 0.0416 0.0638 0.0864 0.1120 0.1425 0.1757 0.2102 0.2458 0.2822 0.3590 0.4377 0.5184 4.20 0.0175 0.0363 0.0560 0.0783 0.1039 0.1314 0.1598 10.1876 0.2185 0.2522 0.3295 0.4061 0.4814 4.30 0.0170 0.0347 0.0548 0.0776 0.1028 0.1301 [0.1583 0.1863 0.2137 [0.2431 0.3185 0.3939 0.4691 4.40 0.0178 0.0348 0.0535 10.0757 0.1004 0.1271 [0.1549 10.1826 0.2100 1 0.2367

-0.3034 0.3771 0.4514

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 66 of 349

__Date: 08/27/03 4.50 0.i8o0 0.0355 0.0526 0.0727 10.0965 0.1223 ! 0.1494 1 0.1765 ] 0.2035 10.2302 0.2857 0.3567 0.4218 4.60 10.0176 0.0358 0.0550 0.0747 0.0943 0.1159 10.1419 10.1682 0.1957 0.2232 0.2790 0.3345 0.4032 4.70 0.0169 0.0348 0.0538 0.0735 0.0933 0.1133 0.1355 0.1616 0.1883 0.2150 0.2694 0.3235 0.37S9 4.80 0.0166 0.0337 0.0510 0.0685 0.0855 0.1043 0.1283 0.1532 0.1787 0.2043 0.2566 0.308S 0.3613 4.90 0.0161 0.0328 0,0498 0.0670 0.0838 0.0997 0.1197 0.1431 0.1672 0.1914 0.2411 0.2909 0.3412 5.00 0.0155 0.0315 0.0480 0.0647 0.0812 0.0968 0.1114 0.1318 0.1543 0.1769 0.2236 0.2706 0.3182 5.10 0.0147 0.0300-0.0458 0.0619 - 10.0778 0.0930 0.1l073

-0.1212 0.1404 [ 0.1614 0.2048.0.2486 0.2932 5.20 0.0141 0.0290 0.0447 0.0612 0.0780 0.0948 I 0.1116 0.1287 0.1463 0.1643 0.2024 0.2424 0.2841 5.40 0.0136 0.0282 0.0438 0.0605 0.0778 0.0955 0.1134 0.13171 0.1504 0.1697 0.2105 0.2536 0.2991 5.60 0.0108 0.0221 0.0337 0.0449 0.057E 0.0720 0.0866 0.1015 0.1168 0.1325 0.1662 0.2020 0.2403 5.80 0.0104 0.0211

-0.0320 0.0430 0.0541 0.0647 0.0746 0.0841 0.0935 0.1050 0.1306 0.1576 0.1854 6.00 0.0099 0.0202 0.0308 0.0417 0.0527 0.0634 0.0736 0.0835 0.0932 0.1029 0.1226 0.1442 0.1679 6.20 0.0093 0.0191 0.0293 0.0398 0.0506 0.0614 0.0722 0.0828 0.0931 0.1033 0.1232 0.1438 0.1657 6.40 0.0089 0.0182 0.0280 0.0384 0.0495 0.0609 0.0722 0.0832 0.0940 0.1045 0.1255 0.1467 0.1689 6.60 0.0087 0.0175 0.0270 0.0371 0.0479 0.0591 0.0705 0.0817 0.0926 0.1034 0.1249 0.1467 0.1693 6.80 0.0083 0.0167 0.0252 0.0339 0.0435 0.0540 0.0648 0.0755 0.0861 0.0966 0.1176 0.1390 0.1611 7.00 0.0079 0.0161 0.0248 0.0338 0.0429 0.0519 0.0608 0.0698 0.0788 0.0880 0.1069 0.1264 0.1467 7.20 0.0076 0.0156 0.0241 0.0331 0.0424 0.0517 0.0611 0.0706 0.0801 O.0899 0.1101 0.1311 0.1530

'7.4' 0.0072 0.0141 0.0207 0.0281

'0.0360 0.0444 0.0530

-0.0617 0.0703

6. 0787 0.0971

.0.1165 0.1370 7.60 0.0067 0.0135 0.0202 0.0266 0.0328 0.0406 0.0487 0.0569 0.0651 0.0731 0.0887 0.1047 0.1212 7.80 0.0060 0.0121 0.0183 0.0244 0.0301 0.0364 0.0436 0.0510 0.0587 0.0667 0.0834 0.1000 0.1162 8.00 0.0053 0.0105 0.0159 0.0210 0.0269 0.0333 0.0400 0.0469 0.0541 0.0616 0.0774 0.0932 0.1087 8.50 0.0053 0.0105 0.0158' 0.0210 0.0263 0.0315 0.0364 0.0411 0.0456 0.0498 0.0578 0.0707 0.0838 9.00 0.0048 0.0096 0.0146 0.0196 0.0247 0.0298 0.0348 0.0397 0.0444 0.0490 0.0573 0.0653 0.0734 9.50 00 0.0088 0.0132 0.0177 0.0221 0.0265 0.0310 0.0356 0.0403 0.0450 0.0536 0.0616 0.0701 10.00 0.0039 0.0080 0.0122 0.0164 0.0206 0.0248 0.0289 0.0330 0.0372 0.0415 0.0502 0.0593 0.0688

Calc Number: GIEO.HfBIP.03.02 Rev Number: 0 Sheet Number: 67 of 349 Date: 08/27103 Table 6-10a. Soil Spectra for M=6. 0, Set 1, Higher Vs Soil Profile Pser 0.ls U

0.

3p O.3 g

0.4w 05iz OA 0.79 0.8g J 0.9R 1.O0w 1.2g 1.4jc 1.6':

0.01 0.1965 0.3677 0.5099 10.6367 0.7458 10.8313 0.9001 0.9656 1.0284 1.0815 1.1877 1.3138 11.4070 0.03 0.2096 0.3838 0.5-251 10.6521 0.7607 10.8457 0.9151 0.9800 1.0411 1.0921 1.1907 1.3194 1.4136 0.04 0.2282 0.4143 0.5576 0.6842 0.7909 0.8747 0.9405 1.0043 1.0634 1.1I108

.JA285 1.328R5 1.4224 0.05 0.1466 0.4492 0.5981 0.7292 [0.8406 0.920 0.9905 1.0407 1.0904 1.1384.' 1.2149 A1.419

'435 0.06 0.2660 0.4817 0.6426 0.7730 I0.8878 0.9673 1.0378 1.0880 1.1290 11.1701 1.2623 11.3518 1.4488R 0.07 0.2983 0.4697 0.6082 0.7305F086 0.9666 1.0549 1.1420 1.2156 11.2682 1.3509 1.4050 1.4344 0.08 0.3356 0.6065 0.8024 0.9732 1 1.11~73 1.2215 1.2908 1.3292 1.3622 1.3902 1.4589 1.5345 1.6002 0.09 0.3750 0.6716 0.8678 1.0368 1.1965 1.3133 1.4032 1.4579 1.4839 1.5210 1.5921 11.6609 1.7179 0.10 0.4333 0.7934 0.9937 1.1105 j1.2203 1.3064 1.3915 1.4372 1.4507 1.4713 1.5256 1.6669 1.7547 0.11 0.4985 0.9403 1.2-228 1.4138 1.5733 11.6976 1.7857 1.8238 1.8226 1.8061 1.7999 1.7977 1.8631 0.12 0.4901 0.9320 1.2436 1.5675 j1.7597 11.8347 1.9SI6 2.0274 2.0600 2.0712 2.0983 2.1201 2.1086 0.13 0.5608 1.0664 1.4588 1.7718 2.0535 12.2757 2.4355 2.5298 2.5833 2.6223 2.6732 2.6837 2.6797 0.14 0.5317 0.9141 1.2638 1.5646 J1.8223 2.0213 2.2086 2.3500 2.4459 2.5082 2.5988 2.6434 2.6514 0.15 0.5089 0.9201 1.2753 1.5295 1.6792 1.7595 1.8510 1.9164 1.9905 2.0576 2.1588 2.2971 236 0.16 0..5934 1.0030 1.3492 1.5904 1.7534

. 1. ~,.2, 1.965-7 2.0763.

2.1725 2.2677 2.3933 2.5271 2.6553 0.17 0.6354 1.0953 11.4526 1.7050 1.8794 2.0022 2.1086 2.2285 2.3463 2.484l1-2.-6842 2.8353

.2.9970-0.18 0.5919 1.0974 11.4296 1.7842 2.1 167 2.3834 2.5787 12.7153 2.8107

.2.9036 3.0771 3.2112 3.2987 0.19 0.5584 1.0962 1.5731 2.0020 2.3826 2.6869 2.9167 13.0871 3.2149 3.3393 13.5648 13.7389 3.8601 0.20 0.5628 1.1174 1.6220 2.0745

'2.4657 2.7837 3.0389 13.2453 3.4136 3.5610 13.8529 14.0866 14.2497 0.21 0.5075 1.0179 1.4891 1.9184 2.2974 2.6216 2.8984 3.1353 3.3359 3.5129 13.8469 14.1166 14.3019 0.22 0.4740 0.9525 1.4062 1.8311 2.2209 2.5618 2.8594 3.1153 3.3323 3.53 17 13.8882 14.1759 14.3870 0.23 0.4241 0.8621 1.3006 1.7269 2.1-210

'2.4710 2.7781 3.0457 3.2777 3.4856 13.8804 4.2071 14.4410 0.24 0.4250 0.8780 1.3452 1.7974 2.2136 2.5834 2.9117 3.2011 3.4557 3.6953 14.1227 14.4666 14.7035 0.25 0.4194 0.8640 11.3251 1.7751 2.1949 2.5747 2.9156 3.2177 3.4834 3.7264 14.1637 4.5241 14.7862 0.26 0.3981 0.8143 11.2517 1.6884 2.1020 2.4798 2.8184 3.1 1?9 3.3820 3.6206 14.0623 4.4236 4.7083 0.27 0.3597 0.7262 1.1147 1.5088 1.884S 2.2443 2.6260 12.9629 3.2564 3.5213 4.0113 4.3968 14.6661 0.28 0.3192 0.6348 0.9666 1.3075 1.6739 2.0484 2.3995 2.7141 2.9949 3.2566 3.7491 4.1595 14.4700 0.29 0.3039 0.5910 0.8683 1.1730 1.5110 11.8571 2.1868 2.4892 2.7668 3.0316 3.6441 4.0769 14.4110 0.30 0.3156 0.6096 0.8648 1.1189 1.4268 11.7378 2.0930 2.4172 2.7202 3.0378 3.7492 4.3438 14.7632 0.31 0.3381 0.6499 0.9182 1.1529 1.3827 11.7001 2.0295 2.3564 2.6683 2.9688 3.5440 4.0487 14.4593 0.32 0.3658 0.7013

-0.9897 1.2421 1.4416 1.5876 1.9034 2.2260 2.5399 2.8487 3.4414 3.9682 14.4040 0.33 0.3966 0.7593 11.0722 1.3484 1.5696 1.7359 1.8623 1.9906 2.2996 2.6040 13.1979 3.7315 14.179 0.34 0.4133 0.7928 1.1234 1.4198 1.6620 1.8456 1.9898 ~2.1080 2.2107 2.3330 2.7298-3.2345 3.6614 0.35 0.4090 0.7893 1.1250 1.4275 1.6765 1.8705 2.0274 2.1533 2.2674 2.3948 2.7197 3.0719 3.4352 0.36 0.3972 0.7695 1.1004 1.4016 1.6518 1.8469 2.0049 2.1317 2.2498 2.3750 2.6981 3.0434 3.3984 0.37 0.3817 0.7421 1.0658 1.3610 1.6067 1.7988 1.9553 2.1088 2.2460 2.3781 2.6796 2.9765 3.3125 0.38 0.3620 0.7052 1.0162 1.3018 1.5604 1.7845 1.9771 2.1388 2.2767 2.4136 2.7124 3.0076 3.2934 0.39 0.3377 0.6713 0.9861 1.2849 1.5524 1.7798 1.9748 2.1379 2.2781 2.4149 2.7124 2.9990 3.2767 0.40 0.3278 0.6526 0.9615 1.2566 1.5227 1.7502 1.9459 2.1113 2.2518 2.3842 2.6763 2.9534 3.2192 0.41 0.3151 0.6291 0.9296 1.2190 1.4821 1.7088 1.9044 12.0679

.2.2046 2.3360 2.6143 2.8784 13.1291 0.42 0.3018 0.6040 0.8955 1.2133 1.5066 1.7378 1.9072 12.0238 2.1533 2.2788 2.5436 2.8282 13.0785 0.43 0.2890 0.6026 0.9425 1.2846 1.5994 1.8477 2.0290 2.1577 2.2550 2.3495 2.574-5 2.8779 13.1519 0.44 0.2754 0.5728 0.9006 1.2303 1.5327 1.8058 2.0422 2.2067 2.3151 2.4091 2.6256 2.8316 13.0234 0.45 0.2582 0.5254

'0.8388 1.1719 1.5065 1.7989 2.0272 2.1815 2.2792 2.4155 2.6611 2.8298 13.0690 0.46 0.2422 0.5164 0.8037 11.0952 1.3886 1.6640 1.9211 2.1527 2.3417 2.5004 12.7782 2.9782 13.1358 0.47 0.2306 0.4991 0.7874 1.0834 1.3840 1.6691 1.9274 2.1554 2.3474 2.5133 12.7970 3.0098 13.1662 0.48 0.2197 0.4740 0.7551 1.0470 1.3472 1.6351 1.8993 2.1349 2.3369 2.5150 12.8221 3.0573 13.2249 0.49 0.2167 0.4415 0.7094 0.9916 1.2840 1.5682 1.8325 210715 2.2815 2.4663 12.7894 3.0415 13.2234 0.50 0.2120 0.4318 0.6537 0.9214 1.2021 1.4784 1.7391 11.9781 2.1893 2.3778 2.7090 2.9679 3.1592 0.51 0.2062 0.4208 0.6368 0.8567 1.1066 1.3709 1.6234 11.8576 2.0670 2.2532 2.5826 2.8444 3.0755 0.52 0.1994 0.4080 10.6187 0.8340 1.0526 1.2653 1.4908 11.7149 1.9166 2.0971 2.4155 2.7266 3.0345 0.53 0.1916 0.3930 0.5977 0.8074 1.0212 1.2305 1.4318 1.6261 1.8117 2.0039

-2.4254 2.8204 3.1359 0.54 0.1829 0.3763 0.5740 0.7776 0.9860 1.1907 1.3883 1.5798 1.7634 1.9588 2.4075 2.8249 3.1712 0.55 0.1739 0.3574 0.5470 0.7430 0.9449 1.1445 1.3381 1.5264 1.7072 1.8829 2.3099 2.7203 3.0601 0.56 0.1706 0.3501 0.5283 0.7057 0.8989 11.0921 1.2804 1.4643 1.6412 1.8127 2.1549 2.5145 2.8394 0.57 0.1646 0.3386 0.5126 0.6862 0.8602 11.0345 1.2162 1.3944 1.5662 1.7325 2.0880 2.4322 2.7437 0.58 0.1597 0.3285 0.4984 0.6689 0.8397 11.0042 1.1655 1.3321 1.5049 1.6824 2.0339 2.3685 2.6745 0.60 0.1512 0.3112 10.4742 0.6394 0.8067 10.9689 1.1262 1.2890 1.4570-1.6287 1.9739 2.3074 2.6155 0.62 0.1429 0.2917 0.4420 0.5933 0.7445 0.930 1.0412 1.1945 1.3520 1.5097 1.8219 2.1308 2.4282 0.64 0.1326 0.2699 10.4098 0.5522 0.6952 0855 0.9750 1.1185 126 1.4126 1.7015 1.9855 2.2583~

0.66 0.1300 0.23 03989 0.5376 1 0.6780 0.8154 0.9519 1.0916 1.2345 1.3775 1.65676 1.9328 2.1976

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 68 of 349

~~~~~~~~Date:

08/27/03 0.68 ] 01331 0.2668 10.4025 0.5428 30.68160 ] 0.8 2 73 0]9691.1.10S 1.2577 1.40J58 1.6974 11.9849 12.263K

-07 01390 0.2752 0.4157 0.5553 30.6923 0.8206 j

.37 1.0714 1.2181 1.3673 1.6636 1.9577 2.2444 0.72 J0.1415 0.2805 0.4249 0.5702 J0.7147 0.8522 j098-1.0948 1.2019 1.3033 1.4965 1.7179 1.9862 0.74 0.1414 0.2828 0.4290 0.5775 30.7272 0.8709 j

.02J1.1302 1.2465 1.3573 1.5687 1.7694 1.9599 0.76 0.1401 0.2830 0.4285 0.5778 30.7294 0.8769 J1.0161 1.1472 1.2701 1.3880 1.6129 1.8263 2.0280 0.78 0.1395 0.2809 0.4239 0.5713 0.7222 0.8704 j1.0116 1.1461 1.2730 1.3950 1.6285 1.849X 2.0590 OIVo~ -0.1447 0.2788-0:4153 0.5592-.---0.7073 0.8537 j-0-9945.1.1296 1.2580..

61:3815 1.6189 1.8444 2.0565 0.82 0.1472 0.2841 0.4064 0.5439 0.6879 0.8313 0.9700 1.1039 1.2319 1.3555 1.5931 1.8189 2.0321 0.84 0.1461 0.2828 0.4055 0.5283 0.6682 0.8079 [0.9436 1.0755 1.2020 1.3246 1.5605 1.7853 1.9972 I0.86 0.1429 0.2775 0.3988 0.5148 0.6509 0.7871 0.9199 1.0496 1.1745 1.2957 1.5294 1.7525 1.9628 0.88 0.1386 0.2703 0.3893 0.5040 0.6370 0.7704 0.9008 1.0286 1.1519 1.2718 1.5035 1.7248 1.9337 0.90 0.1T339 0.2623 0.3815 0.49-65 0.6262 0.7572 30.8857 1.0118 1.1338 1.2525 11.4824 1.7021 1.9099 0.92 0.1303 0.2600 0.3834 0.5013 0.6173 0.7461 30.8728 0.9974 1.1181 1.2358 1.4639 1.6822 1.8888 0.94 0.1294 0.2593 0.3846 0.5054 0.6215 0.7356 0.8605 0.9834 1.1029 1.2194 1.4456 1.6624 1.8680 0.96 0.1283 0.2582 0.3851 0.5086 0.6280 0.7396 0.8476 0.9687 1.0868 1.2020 1.4262 1.6414 1.8458 0.98 0.1277 0.2571 0.3848 0.5103 0.6322 0.7466 0.8516 0.9529 1.0694 1.1833 1.4052 1.6188 1.8218 100 0.27 0.2559 0.3835 0.5097 0.6333 0.7499 0.8572 0.9570 1.0510 1.1635 1.3830 1.5946 1.7959 105 0.1248 0.2499 0.3743 0.4992 0.6232 0.7423 0.8532 0.9571 1.0545 1.,1480 1.3256 1.5292 1.7251

,I510 0.1191 0.2392 0.3695 0.50-14.-0.633t-0.7621 0.822 ~0.9935 1.0953.

p1899 1.3602 1:5103 I.1.6474 1.15 0.1153 0.2388 0.3677 0.4986 0.6304 0.7590 0.8795 0.9906 1.0913 1.1832 1.3453 1.4834 1.35995~

1.20 0.1004

-0.2043' 0.3090 0.4181 0.5329 0.6484 0.7616 0.8700 0.9728 1.0705 1.2499 1.4077 1.559 1.25 0.0916 0.1872 0.2854 0.3873 0.4939 0.6012 0.7062 0.8070 0.9024 0.9927 1.1671 1.3380 1.4954 1.30 0.0870 0.1753 0.2632 0.3528 0.4466 0.5418 0.6368 0.7313 0.8244 0.9157 1.0919 1.2623 1.4244 1.35 0.0822 0.1658 0.2493 0.3332 0.4179 0.5032 0.5889 0.6754 0.7624 0.8531 1.0345 1.2135 1.3872 11.40 10.0772 0.1562 0.2354 0.3152 0.3960 0.47-75 0.5595 0.6425 10.7263 0.8205 1.0077 1.1940 1.3761 1.45 0.0723 10.1466 10.2219 0.2982 0.3755 0.4538 0.5328 10.6166 0.7101 0.8045 0.9926 1.1800 1.3634 1.50 0.0673 0.1375 0.2100 0.2837 0.3583 0.4339 0.5122 0.6004 0.6910 0.7826 0.9662 1.1503 1.3314 1.55 0.0637 0.1302 0.1995 0.2702 0.3419 0.4145 0.4891 0.5734 0.6600 0.7476 0.9241 1.1020 1-.2780 1.60 0.0605 0.1233 0.1888 0.2560 0.3245 0.3940 0.4644 0.5360 0.6176 0.7005 0.8679 1.0379 1.2073 1.65 0.0570 0.1163 0.1779 0.2413 0.3064 10.3729 0.4407 0.5091 0.5783 0.6479 0.8031 0.9642 1.1264 1.70 0.0533 0.1093 0.1679 0.2281 0.2899 10.3534 0.4182 0.4838 0.5499 0.6164 0.7502 0.8898 1.0458 1.75 0.0497 0.1022 0.1573 10.2141 0.2725 10.3326 0.3942 10.4565 0.5195 0.5828 0.7098 10.8383 0.9722 1.80 0.0458 10.0944 0.1458 10.1989 0.2535 10.3101 0.3682 10.4272 0.4868 0.5467 0.6669 10.7884 10.9101 1.85 0.0417 0.0863 0.1337 10.1828 0.2336 10.2864 0.3409 10.3963 0.4525 0.5090 0.6223 0.7368 10.8517 1.90.

0.0383 0.0782 0.1214 0.1665 0.2134 0.2622 0.3130 0.3648 0.4175 0.4706 0.5768 0.6843 10.7923 1.95 0.0366 0.0748 0.1142 0.1543 0.1955 0.2383 0.2853 0.3335 0.3826 0.4321 0.5312 0.6316 10.7327 2.00 0.0349 0.0713 0.1089 0.1474 0.1868 0.2269 0.2673 0.3079 0.3485 0.3943 0.4862 0.5796 10.6739 2.05 0.0331 0.0677 0.1035 0.1401 0.1777 0.2159 0.2545 0.2933 0.3319 10.3704 0.4466 0.5294 10.6175 2.10 10.0313 0.0641 0.0980 0.1328 0.1684 0.2048 0.2414 0.2782 0.3 150 0.3516 10.4240 10.4962 10.5677 2.15 0.0296 0.0605 0.0926 0.1254 0.1592 0.1936 0.2284 0.2632 0.2981 0.3328 0.4015 0.4701 10.5379 2.20 0.0278 0.0570 0.0873 0.1183 0.1502 10.1827 0.2156 0.2486 0.2815 0.3144 10.3795 0.4444 0.5087-2.25 0.0262 0.0536 0.0822 0:'1114 0.1416 0.1723 0.2033 0.2344 0.2656 0.2967 0.3583 0.4197 10.4806 2.30 0.0254 0.0513 0.0775 0.1050 0.1334 0.1623 0.1916 0.2210 0.2505 0.2799 0.3381 0.3964 10.4613 2.35 0.0254 0.0515 0.0781 0.1051 0.1324 0.1602 0.1886 0.2178 0.2478 0.278.5 0.3415 0.4066 10.4739 2.40 0.0237 0.0483 0.0735 0.0992 0.1254 0.1522 0.1796 0.2078 0.2369 0.2666 0.3275 0.3908 10.4563 2.50 0.0202 0.0406 10.0614 0.0830 0.1056 0.1288 0.1522 0.1759 0.1995 0.2231 0.2700 0.3165 0.3684 2.60 0.0204 0.0413 0.0626 0.0842 0.1061 0.1283 0.1508 0.1736 0.1966 0.2199 10.2672 10.3160 0.3660 2.70 0.01897 0.0380 0.0579 0.0783 0.0992 0.1206 0.1425 0.1647 0.1872 0.2098 10.2551 0.3013 0.3489 2.80 0.0164 0.0332 0.0508 0.0690 0.0877 0.1070 0.1270 0.1473 0.1681 0.1889 0.2308 0.2733 0.3167 2.90 0.0149 0.0304 0.0463 0.0626 0.0789 0.0954 0.1119 0.1283 0.1447 0.1611 0.1952 0.2323 0.2701 3.00 0.0136 0.0278 0.0426 0.0577 0.0730 0.0885 0.1040 0.1195 0.1349 0.1504 0.1813 0.2125 0.2437 3.10 0.0127 0.0256 0.0387 0.0521 0.0661 -0.0803 0.0946 0.1088 0.1231 0.1374 0.1660 0.1949 0.2240 3.20 0.0119 0.0241 0.0366 0.0492 0.0619 0.0747 0.0876 0.1005 0.1134 0.1262 0.1518 10.1774 10.2032 3.30 0.0109 0.0222 0.0337 0.0453 0.0571 0.0691 10.0811 0.0932 0.1054 10.1175 0.1416 10.1657 10.89 3.40 0.0099 0.0200 0.0304 0.0410 0.0518 0.0627 0.0738 0.0850 0.0962 10.1074 0.1306 10.1556 10.18j 3.50 0.0097 0.0193 0.0287 0.0383 0.0478 0.0572 0.0665 0.0767 0.0869 0.0972 0.1176 10.1399 10.163 3.60 0.0096 0.0194 0.0291 0.0389 0.0487 0.0584 0.0682 0.0778 0.0875 0.0970 0.1161 10.1351 10.1540I 3.70 0.0090 0.0181 0.0275 0.0370 0.0465 0.0561 0.0657 0.0753 0.0849 0.0945 0.1136 10.1326 10.1515 3.80 0.0086 0.0172 0.0259 0.0348 0.0439 0.0531 0.0624 0.0717 0.0811 0.0904 0.1091 10.1278 10.1463 3.90 0.0082 0.0165 0.0248 0.0332 0.0417 0.0503 0.0590 0.0677 0.0765 0.0854 0.1033 10.1213 10.1395 4.00 0.0077 0.0155 0.0233 0.0311 0.0391 0.0472 0.0554 10.0637 0.0720 0.0804 0.0974 10.1146 10.1319 4.10 0.0071 0.0143 0.0215 0.0287 0.0361 10.0435 0.051 0.58

.66 0074

.92 0163

.25 4.20 0.0067 0.0135 0.0203 0.0271 0.0340 0.40 008 0.51

.62 0091f.83 0075I.13 4.30 0.0065 0.0132 0.0198 0.0264 0.33 0.40 0.48 0.56 0065 0064 0012 0052 019 4.40 0.063 0.0126 0.19 0.25 002-00-

.41

.57 0083 005

.73

.99 015

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 69 of 349 Date: 0/27/03 4.50 0.0059 0.0120 0.0181 0.0243 0.0305 0.0368 [ 0.0430 0.0493 0.0556 0.0620 0.0747 0.0877 10.1011 4.60 0.0056 0.0112 0.0170 0.0228 0.0287 0.0346 0.0405 0.0465 0.0525 0.0584 l 0.0705 0.0827 0.0953 4.70 0.0051 0.0103 0.0157 0.0211 0.0266 0.0321 0.0377 0.0432 0.0488 0.0544 0.0657 0.0771 1 0.0881 4.80 0.0050 0.0102 0.0154 0.0207 0.0260 0.0313 0.0366 0.0418 0.0470 0.0522 0.0626 0.0728 l 0.0829 4.90 0.0049 0.0100 0.0151 0.0203 0.0256 0.0308 0.0360 0.0413 0.0465 0.0516 0.0620 0.0723 0.0824 5.00 0.0048 0.0097 0.0147 0.0198 0.0249 0.0300 0.0352 0.0403 0.0454 0.0505 0.0608 0.0710 0.0813 5.10 0.0046 0.0093 0.0141-0.0190 0.0240-

. 0.02$9 0.0340- -0.0390;

.0.0440 0.0490

.. 0.0590 0.0691 0.079.0 5.20 0.0044 0.0089 0.0134 0.0181 0.0229 0.0276 0.0325 0.0373 0.0422 0.0470 0.0568 0.0666 0.0763 5.40 0.0040 0.0079 0.0118 0.0160 0.0202 0.0245 0.0289 0.0333 0.0378 0.0422 0.0517 0.0613 0.0711 5.60 0.0036 0.0072 0.0107 0.0141 0.0177 0.0215 0.0255 0.0296

.0.0338 0.0381 0.0468 0.0557 0.0647 5.80 0.0033 0.0065 0.0096 0.0127 0.0157 0.0187 0.0221 0.0257 0.0295 0.0333 0.0410 0.0489 0.0569 6.00 0.0029 0.0057 0.0086 0.0115 0.0144 0.0173 0.0203 0.0232 0.0262 0.0291 0.0348 0.0416 0.0485 6.20 0.0027 0.0053 0.0080 0.0107 0.0133 0.0159 0.0185 0.0212 0.0240 0.0267 0.0320 0.0371 0.0420 6.40 0.0026 0.0052 0.0078 0.0105 0.0130 0.0156 0.0180 0.0204 0.0228 0.0252 0.0301 0.0350 0.0400 6.60 0.0025 0.0051 0.0076 0.0102 0.0127 0.0152 0.0176 0.0200 0.0223 0.0247 0.0295 0.0343 0.0392 6.80 0.0024 0.0049 0.0074 0.0098 0.0123 0.0147 0.0170 0.0194 0.0217 0.0240 0.0287 0.0334 0.0382 7.00 0.0023 0.0047 0.0071 0.0094 0.011O 0.0141 0.0164 0.0187 0.0210 0.0232 0.0278 0.0323 0.0369 7.20 0.0022 0.0045.

0.0068 0.0090 0.0113 0.0136 0.0158 0.0180 0.0202 0.0224 0.0267 0.0311 0.0355 7.40 0.0021

&:0.0043 0.0065 - 0.0086 0.0108 -

0.0129 0.0151 0.0172 0.0193 J 0.0214

.0.0256-%

- 0.0298 0.0340 7.60 0.0020 0.0041 0.0061 0.0082 0.0103 0.0123 0.0144 0.0164 0.0184 0.0204 0.0244 0.0285 0.0325 7.80 0.0019 0.0039 0.0058 0.0078 0.0098 0.0117 0.0137 0.0156 0.0175 0.0194 0.0233 0.0271 0.0309 8.00 0.0018 0.0037 0.0055 0.0074 0.0093 0.0111 0.0130 0.0148 0.0166 0.0185 0.0221 0.0257 0.0294 8.50 0.0016 0.0032 0.0048 0.0064 0.0081 0.0097 0.0113 0.0129 0.0145 0.0161 0.0193 0.0224 0.0256 9.00 0.0014 0.0028 0.0042.

0.0056 0.0070 0.0084 0.0098 0.0112 0.0126 0.0140 0.0167 0.0195 0.0222 9.50 0.0012 0.0024 0.0036 0.0049 0.0061 0.0073 O.OOS5 0.0097 0.0109 0.0121 0.0145 0.0168 0.0193 10.00 0.0010 0.0021 0.0032 0.0042 0.0053 0.0064 0.0074

.008S5 0.0095 0.0105 0.0125 0.0146 0.0167

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 70 of 349 Date: 08/27/03 Table 6-lOb. Soil Spectra for M=6.0. Set 2. Higher Vs Soil Profile Per (stc)

O.lg 0.2g 0.3g 0.4g 0.5gt 0.6e 0.7g 0.8g 0.9e L OP I

.g t4g 16 0.01 0.1590 0.2941 0.4300 0.5733 1 0.7119 0.8310 0.9312 1.0162 1,0948 1.1731 1.3342 1 1.4617 1.5519 0.03 0.1634 0.3026 0.4407.

0.5R69 j 0.7275 0.8482 0.9482 1.0339 1.1118 1.1909 13538 1.4813 1.5712 0.04

0. 1716 0.3172 1 0.4525 J.0.5957 1 0.738 0.8606 0.9619 1.0486 1.1272 1.2068 11.3712 1 1.4996 11.5189 0.05 1 0.1885 I- 0.341A: 1 0.4696 1 0 61R4 i 0.7614 1 0.8-84 J 0<9875 1.0763 1.1542 1 1.2315 1.3990.-S248 I 1 16157 1...

0.06 0.2640 0.4376 0.5159 0.6363 0.7873 0.9162 1.0191 1.1074 1.1855 1.2657

[14350 11.5611 1.6532 0.07 0.2831 0.5071 0.6311 0.7055 0.8339 0.9525 1.041 1 41.1381 1.2183 1.2995 1.4692 1.5993 [1.6947 0.08 0.2892 0.5514 0.7617 0.8953 0.9832 1.1357 I.2504 41.3350 1.4016 1.4760 1.6405 1.7564 1.8308 0.09 0.3138 0.5969 0.8725 1.0592 1.1723 1.2244 1.2718 41.3243 1.3854 1.4541 1.6104 1.750-2 1.8613 0.10 0.3343 0.6077 0.8757 1.1092 1.2486 1.3000 1.3907 j1.4538 1.4903 1.5-244 1.6714 1.8228 1.9284 0.11 0.4489 0.493 1.1865 1.4679 j1.6988 1.R721 2.0147 J 2.1318 2.2070 2.2555 2.3453 2.3810 2.4024 0.12

0. 4470 0.8564 1.2230 1.5251 j1.7892 2.0053 2.1902 2.3331 2.4379 2.5271 2.6438 2.7037 2.7522 0.3

.4274 0.8329 1.2169

1. 55307 41.8513 2.0948 2.3027 12.4649 2.5887 12.6958 2.8529 2.9486 3.0216 0.14 0.4160 0.8563 1.2821 1.6109 41.9143 2.1802 2.3959 2.5839 2-.7-435 I2.8733 13.0700 13.2113 13.30'21 0.15 0.4340 0.7743 1.1277 1.4642 1.7513 1.9494 2.0861 2.1911 12.3013 12.4133 2.6098 2.7477 j2.9487 0.16 0.5323 0.9495 1.2375 1.5033 1.7530 1.9660 2.1544-2.3065 2.4278 2.5633 2.8305 2.9913 3.2452 6;i 1 0.5980 -0.9814' 1.3619 1.6432 1.8902 2.1157

-'21402&v- --2.6838 2.9674 --,3-.2544 3.7440 +-,4.0329 4.99 0.18 0.5575 1.0629 1.4981 1.8086 2.04414 2.2182 2.3630 2.4840 2.5920 2.8239 3.2028 3.4410 3.569 0.19 0.5549 1.0714 1.5179 1.8239 2.1370 2.4774 2.7427 2.9661 3.1592 3.3481 3.6618 3.8510 369864 0.20 0.4986 0.9446 1.4236 1.9289 2.3593 2.6903 2.9613 3.1976 3.4138 3.6242 4.0364 4.3542 4.6032 0.21 0.4586 0.9008 1.3373 1.7661 2.1435 12.4586 2.7102 2.9374 3.1749 3.4144 3.8689 4.2223 14.5019 0.22 0.4512 0.8786 1.3140 1.7444 2.1474 2.4942 2.7829 3.0261 3.2683 3.5183 3.9813 4.3451 4.6454 0.23 0.4361 0.8435 1.2536 1.6854 2.1099 2.4892 2.8118 3.0949 3.3257 3.5520 4.0131 4.4099 4.7374 0.24 0.425 1 0.8204 1.2291 1.6772 2.1297.2.5353 2.8905 3.1967 3.4607 3.7002 4.1846 4.6144 4.9788 0.25 0.4380 0.68 1.3070 1.7888 2.2721 2.7059 3.0796 3.4081 3.6841 3.9333 4.4344 4.8753 5.2605 0.26 0.3824 0.7625 1.1490 1.5577 1.9999 2.4472 2.8635 3.2587 3.5972 3.9114 4.4563 4.9142 5.3569 0.27 0.3249 0.6605 1.0372 1.4651 1.9163 2.3487 2.7636 3.1417 3.4812 3.7890 4.4651 5.0749 5.5984 0.28 0.3269 0.6439 0.9616 1.2922 1.6459

2.0239 2.4232 2.8174 3.185-7 3.5311 4.1684 4.7594 5.2755 0.29 0.3263 0.6432 0.9427 1.2436 1.5696 1.9020 2.2428 2.5848 2.9064 3.2075 3.7743 4.3688 4.8877 0.30 03608 0.6560 0.9355 1.2246 1.5243 11.8197 2.1175 2.4153 2.6953 2.9596 3.4724 3.9767 4.5778 0.31I 0.3786 0.6993 0.9644 1.1995 1.4814 1.7505 2.0163 2.2801 2.5282 2.7637 3.2252 3.8927 4.5061 0.32 10.3806 0.7086 0.9875 1.2226 1.4444 1.6956 1.9375 2.1747 2.3970 2.6085 3.1124 3.7402 4.3289 0.33 0.3760 0.7041 0.9880 1.2326 142 1.6605 1.8849 2.1019 2.3031 2.4940 2.9590 3.5420 4.1001 0.34 0.3741 0.7021 0.9874 1.2371

.42 1.6498 1.8538 2.0549 2.2391 2.4131 2.7962 3.3303 3.8533 0.35 0.3768 0.7080 0.9928 1.2425 1.4709 1.6707 1.8668 2.0427 2.2037 2.3640 2.6890 3.1272 3.6126 0.36 0.3792 0.7128 0.9949 1.2398 1.4650 1.6544 1.8491 2.0281 2.1872 2.3350 2.6376 2.9924 3.3706 0.37 0.3771 0.07 0.9849 1.2200 1.4720 1.6978 1.8925 2.0617 2.2012 2.3147 2.5869 2.9302 3.2717 0.38 0.3651 0.6944 1.0039 1.2841 1.5387 1.7676 1.9704 2.1448 2.2875 2.4011 2.6379 2.8991 3.1672 0.39 03392 0.6687 0.9750 1.2611 1.5265 1.7480 1.9473 2.1246 2.2665 223778 2.6032 2.8655 3.0885 0.40 0.3304 0.6600 0.9768 1.2790 1.5612 1.7983 1.9993 12.1790 2.3241 2.4340 2.6776 2.9334 3.1492 0.41 0.3284 0.6646 0.9925 1.3068 1.6002 1.8485 2.0586 2.2405 2.3875 2.3209 2.8013 3.0633 3.2855 0.42 0.3073 0.6269 0.9405 1.2442 1.5297 1.7753 1.9804 2.1569 2.3023 2.4654 2.7460 3.0094 3.2305 0.43 0.2814 0.5743 10.8637 1.1506 1.4244 1.6661 1.8729 2.0466 2.2128 2.3814 2.6614 2.9162 3.1277 0.44 0.2602 0.5356 0.8119 1.0868 1.3531 1.5947 1.8082 2.0294 2.2243

'2.3946 2.6672

'2.9148 3.1140 0.45 0.2520 0.5097 0.7682 1.0303 1.2933 1.5464 1.7812 1.9974 2.1849 2.3476 2.6054 2.8958 3.1691 0.46 0.2377 0.4817 0.71259 0.9734 1.2229 1.4610 1.6819 1.8863 2.0717 2.2662 2.6095 2.9274 3.2071 0.47 0.2243 0.4560 0.6889 0.9262 1.1657 1.3952 1.6122 1.8377 2.0479 2.2391 2.5795 2.8963 3.1777 0.48 0.2095 0.4286 0.6507 0.8787 1.1106 1.3354 1.5655 1.7856 1.9887 2.1754 2.5073 2.8177 13.0973 0.49 0.1961 0.4006 0.6116 0.8311 1.0574 1.2838 1.5047 1.7164 1.9113 2.0917 2.4125 2.7172 2.9921 0.50 0.1892 10.3857 10.5881 0.7979 1.0142

-1.2307 1.4424 1.6451 1.8325 2.0059 2.3176 2.6144 2.8856 0.51 0.1831 0.3727 0.5673 0.7686 0.9760 1.1833 1.3872 1.5817 1.7632 1.9307 2.2353 12.5272 2.7972 0.52 0.1784 0.3623 0.5505 0.7450 0.9448 1.1455 1.3425 1.5315 1.7080 1.8715 2.1718 2.4617 2.7315 0.53 0.1747 0.3542 0.5378 0.7265 0.9204 1.1159 1.3078 1.4929 1.6659 1.8270 2.1254 2.4149 2.6858 0.54 0.1717 0.3477 0.5273 0.7113 0.9008 1.0918 1.2797 1.4619 1.6323 1.7921 2.0895 2.3797 2.6520 0.55 0.1691 0O.3418 0.5177 I0.6978 0.8832 1.0701 1.2546 1.4342 1.6022 1.7612 2.0575 2.3483 2.6214 0.56 0.1664 0.3358 0.5082 0.6845 0.8656 1.0484 1.2301 11.4065 1.5720 1.7302 2.0244 2.3152 2.5879 0.57 0.1634 0.3295 0.4984 0.6705 0.8473 1.0265 1.2045 1.3776 1.5411 1.6972 11.9895 2.2780 2.5493 0.58 0.1605 0.3231 0.4883 0.6562 0.8289 1.0041 1.1781 1.3478 1.5089 1.6624 1.9522 2.2374 2.5064 0.60 0.1549 0.3110 0.4692 0.6294 0.7936 0.9606 1.1275 1.2909 1.4457 1.5948 1.8771 2.1561 2.4206 0.2 0.1507 0.3017 0.4541 0.6076 0.7647 0.9248 1.0851 1.2428 1.3930 1.5376 1.8144 2.0872 2.3474 06 0.1 478 0.2949 0.4429 0.5911 0.7423 0.8967 1.0518 1.2046 1.3506 1.4922 1.7641 2.0329 220

[0.6 10.1448 0.2885 f0.4327 0.5763 0.7222 0.8714 1.0216 1.1698 123118 1.4501 1.7178 1.9823 2.2377

Caic Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 71 of-34i9

______~D ate: 08/2.7/03) 0.63 30.1408 0.2801 10.4199 0.5586 0.6992 0.8428 ]0.9876 1.1309 1.2682 1.4031 1.6652 1.9239 12.1754 0.70-j- -0.1514 0.2932 10.4254 0.5447

.0.6714 0.8089 0.9478 1.0853 1.2176 1.3477 1.6024 1.3538 2.0996 0.72 j0.1585 0.3083 0.4499 0.5798 0.7032 0.8185 0.922 1.0361 1.1624 1.2870 1.5322 1.7744 2.0124 0.74 j0.1606 0.3134 0.4589 0.5945 0.7242 0.3470 0.9628 1.0711 1.1675 1.2586 1.4598 I.6914 1.9202 0.76 0.1588 0.3107 0.4563 0.5931 0.7257 0.8513 0.9705 1.0821 1.1814 1.2-742 1.4548 1.6426

1. 4402 0.78 0.1546 0.3032 0.4461 0.5818 0.7137 0.8398 0.9595 1.0717 1.1716 1.2645 1.4429 1.6264 1.8171 0.80... 0.1548 0.2984 0.4340 0.5645 0.6938 10.8182 0.9367 1.48 1.1499 1.2500 1.4346 11.6059 1.7726 0.82 0.1576 0.3041 0.4419 0.5704 0.6963 10.8198 0.9415 1.0594 1.1673 1.2692 1.4597 1.6401 1.8087 0.84 0.1571 0.3036 0.4415 0.5693 0.6941 10.8162 0.9364 1.0529 1.1596 1.2606 1.4508 1.6341 1.8069 0.86 0.1539 0.2985 0.4347 0.5605 0.6824 10.8006 0.9182 1.0289 1.1316 1.2293 1.414S 1.5962 1.7682 0.88 0.1576 0.3070 0.4491 0.5826 0.7138 0.8424 0.9675 1.0864 1.1923 1.2891 1.4625 1.6245 1.7800 0.90 0.1605 0.3144 0.4618.

0.6004 0.7356 0.8678 0.9970 1.1209 1.2332 1.3370 1.5252 1.7000 1.8650 0.92 0.1595 0.3149 0.4655 0.6084 0.7476 0.3834 1.0159 1.1438 1.2612 1.3709 1.5726 1.7594 1.9345 0.94 0.1559 0.3102 0.4613 0.6060 0.7473 0.8854 1.0203 1.1504 1.2711 1.3848 1.5957 1.7922 1.9760 0.96 0.1508 0.3013 0.4498 0.5932 0.7337 0.8712 1.0057 1.1361 1.2575 1.3725 1.5879 1.7898 1.9798 0.98 0.1446 0.2893 10.4328 0.5721 0.7091 0.8437 0.9756 11.1037 1.2235 1.3379 1.5532 1.7570 1.9491 1.00 0.1376 0.2755 0.4124 0.5461 0.6779 0.8078 0.9353 1.0594 1.1763 1.2881 1.5003 1.7023 1.8937 1.05 0.1194 0.2400 0.3603 0.4785 0.5959 0.7122 0.8269 0.9392 1.0461 1.1492 1.3474 1.5388 1.7213 1.10.

0.1097 0.2252.

l.34 -.0.4652 0.58.56.

.0.7053 0.21.

.94I2 1.0530 1.1579

..1.3479 1.17..z.1,.6,1 1.15 0.0989 0.2004 0.3034 0.4062 0.5090 0.6168 0.7253 0.8335 0.9403 1.0482 1.2550 1.4475 1.6271 1.20 0.0934 0.1894 0.2903 0.3995 0.5121 0.6277 0.7451 0-.8634 0.9810 1.0965 1.3189 1.5283 1.7242 1.25 0.0894 0.1853 0.2858 0.3912 0.4998 0.6120 0.7270 0.8441 0.9617 1.0781 1.3050 1.5211 1.7249 1.30 0.0823 0.1714 0.2660 0.3655 10.4674 0.5725 0.6800 0.7899 0.9020 1.0141 1.2354 1.4468 1.6478 1.35 0.0742 0.1543 0.2393 0.3295 0.4225 0.5185 0.6169 0.7178 0.8210 0.9246 1.1310 1.3310 1.5239 1.40 0.0669 0.1388 0.2147 0.2951 0.377S 0.4632 0.5506 0.6401 0.7312 0.8225 1.0039 1.1802 1.3501 1.45 0.0597 0.1226 0.1882 0.2579 0.3299 0.4039 0.4797 0.5571 0.6358 0.7184 0.8969 1.0787 1I.2612 1.50 0.0561 0.1160 0.1791 0.2455 0.3140 0.3849 0.4580 0.5332 0.6114 0.6924 0.8632 1.0423 11.2277 1.55 0.0541 0.1099 0.1674 0.2270 0.2898 0.3562 0.4251 0.4965 0.5713 0.6490 0.8129 0.9907 11.1770 1.60 0.0504 0.1028 0.1568 0.2139 0.2728 0.3339 0.3975 0.4640 0.5346 0.6095 0.7695 0.9384 1.1150 1.65 0.0466 0.0963 0.1483 0.2030 10.2591 0.3169 0.3766 0.4389 0.5050 0.5744 0.7226 0.8796 1.0443 1.70 0.0446 0.0907 0.1380 0.1872 30.2399 0.2944 0.3505 0.4088 0.4705 0.5351 0.6726 0.8187 0.9726 1.75 0.0422 0.0860 0.1310 0.1775 0.2249 0.2734 0.3233 0.3749 0.4291 0.4858 0.6073 0.7375 0.8752 1.80 0.0394 0.0807 0.1238 0.1691 j0.2156 0.2636 0.3130 0.3641 0.4174 0.4722 10.5844 0.6970 0.8100 1.85 0.0376 0.0772 0.1187 0.1623 J0.2072 0.2536 0.3013 0.3507 0.4024 0.4555 10.5650 0.6752 0.7862 1.90 0.0352 0.0726 0.1118 0.1532 0.1960 0.2402 0.2858 0.3330 0.3824 0.4334 0.5387 0.6453 0.7528 1.95 0.0325 0.0672 0.1037 0.1425 I0.1827 0.2244 0.2674 0.3119 0.3586 0.4069 0.5070 0.6086 0.7112 2.00 0.0299 0.0615 0.0951 0.1310 1 0.1683 0.2070 0.2471 0.2886 0.3323 0.3774 0.4713 0.5670 0.6639 2.05 0.0277 0.0565 0.0867 0.1191 0.1533 0.1890 0.2259 0.2643 0.3047 0.3465 0.4338 0.5231 0.6137 2.10 0.0269 0.0548 0.0841 0.1148 0.1462 0.1783 0.2109 0.2444 0.2792 0.3156 0.3962 0.4790 0.5634 2.15 0.0259 0.0529 0.0811 0.1107 0.1410 0.1720 0.2035 0.2358 0.2694 0.3036 0.3734 0.4425 I0.5150 2.20 0.0249 0.0508 0.0779 0.1063 0.1355 0.1652 0.1956 0.2266 0.2589 0.2918 10.3588 0.4254 0.4915 2.25 0.0239 0.0487

-0.0746 0.1019 0.1299 0.1584 0.1876 0.2174 0.2483 0.2798 0.3442 10.4081 10.4717 2.30 0.0229 0.0467 0.0715 0.0977 0.1245 0.1519 0.1798 0.2084 0.2380 0.2683 0.3299 10.3913 0.4524 2.35 0.0219 0.0448 0.0686 0.0937 0.1194 0.1457 0.1725 0.1999 0.2284 0.2574 0.3165 0.3755 0.4341 2.40 0.0223 0.0452 0.0686 0.0927 0.1172 0.1421 0.1674 0.1931 0.2194 0.2473 0.3041 0.3608 0.4172 2.50 0.0201 0.0410 0.0624 0.0846 0.1073 0.1305 0.1543 0.1785 0.2037 0.2295 0.2823 0.3357 0.3 910 2.60 0.0183 0.0373 0.0571 0.0780 0.0995 0.1215 0.1439 0.1668 0.1905 0.2146 0.2640 0.3134 0.3627 2.70 0.0172 0.0350 0.0536 0.0732 0.0934 0.1141 0.1351 0.1567 0.1789 0.2016 0.2480 0.2946 0.3411 2.80 0.0161 0.0329 0.0504 0.0688 0.0877 0.1072 0.1270 0.1473 0.1682 0.1896 0.2334 0.2774 0.3214 2.90 0.0151 0.0308 0.0472 0.0645 0.0823 0.1006 0.1192 1 0.1383 0.1580 0.1782 10.2194 0.2610 0.3027 3.00 0.0142 0.0288 0.0441 0.0602 0.769 0.0940 0.1115 0.1294 0.1480 0.1669 0.2057 0.2449 0.2843 3.10 0.0134 0.0271 0.0410 0.0559 0.0715 10.0875 0.1038 0.1206 0.1379 0.1556 0.1920 0.2289 0.2660 3.20 0.0121 0.0246 0.0378 0.0517 0.0661 10.0810 0.0962 0.1118 0.1279 0.1444 0.1784 0.2130 0.2478 3.30 0.0111 0.0226 0.0347 0.0475 0.0608 0.0746 0.0886 0.1031 0.1181 0.1334 0.1650 0.1973 0.2299 3.40 0.0103 0.0210 0.0318 0.0434 0.0557 0.0683 0.0813 0.0946 0.1084 0.1226 0.1519 0.1819 10.2123 3.50 0.0095 0.0194 0.0295 0.0399 0.0507 0.0622 0.0741 0.0864 0.0991 0.1122 0.13912 0.1670 10.1953 3.60 0.0088 0.0179 0.0272 0.0369 0.0467 0.0567 0.0673 0.0786 0.0902 0.102-2 10.1271 0.1528 0.1791 3.70 0.0084 0.0168 0.0251 0.0338 0.0429 0.0522 0.0617 0.0716 0.0819 0.0928 10.1157 0.1393 0.1638 3.80 0.0082 0.0164 0.0245 0.0326 0.0407 0.0489 0.0571 0.0656 0.0751 0.0851 10.1061 0.1279 0.1505 3.90 0.0079 0.0159 0.0238 0.0317 0.0396 0.0476 0.0555 0.0635 0.0713 0.0790 0.0971 0.1171 0.1379 4.00 0.0077 0.0154 0.0231 0.0308 0.0385 0.0462 0.0540 0.0617 0.0693 0.0768 0.0915 0.1070 0.1261 4.10 0.0075 0.0149 0.0224 0.0298 0.0373 0.0448 0.0523 0.0599 0.0673 0.0746 0.0890 0.1030 0.1167 4.20 0.0072 0.0145 0.0217 0.0289 0.0361 0.0434 0.0507 0.0580 0.0652 0.0723 0.0863 0.1000 0.1134 4.30

.0070

-0.0140 0.0210 0.0279 0.0349 0.0420 0.0491 0.0561 0.0631 0.0701 0.0837 0.0970 0.1100 4.40 10.0067 10.0135 10.0202 0.0270 0.0337 0.0406 0.0474 0.0543 10.0611 0.0678 10.0810 10.0939 10.1067

Calc Number: GEO..HB[P.03.02 Rev Number: 0 Sheet Number: 72 of 349 Date: 08/27/03 4.50 0.0065 10.0130 0.0195 10.0260 0.0326 1 0.0392 10.0458 0.0524 10.0590 10.0655 0.07S3 0.0909 0.1032 4.60 0.0063 0.0126 0.018810. 02 0.0314 ; 0.0378 j 0.0442 0.0506 0.0569 0.0632 0.0757 O0.079 0.0999 4.70 0.0060 0.0121 0.0182 0.0242 0.0303 0.0364 10.0426 0.0488 0.0549 0.0610 0.0731 0.0849 0.0965 4.80 0.0058 0.0117 0.0175 0.0233 0.0292 0.0351 0.0411.0.04711 0.0530 0.0589 0.0705 0.082,0 0.0932 4.90 0.0056 0.0112 0.0169 0.0225 0.0281 0.0338 [ 0.0396 0.0453 J 0.0511 0.0568

-0.0680 0.0791 0.0900 5.00 0.0054 0.0108 0.0162 0.0216 0.0271 0.0326 4 0.0381 0.0437 4 0.0492 0.0547 (0.0656 4 0.0763 0.0869

  • 5.10 0.0052.

0.0104 I 0.0156.

0.020S 0.0261 0.0314.-

0.0D.367 0.0421

.Q.0474 0.0527 0.0633 1 0.0736 0.0839

+

I--

+-

+-----4

+



+

t

+

5.20 0.0050 0.0100 1 0.0150 0.0201 0.0251 0.0302 0.0354 0.0405 0.0457 0.0508 0.0610 1 0.0710 0.0809 5.40 0.0046 0.0093 0.0139 0.0186 0.0233 0.0280 0.0328 0.0376 0.0424 0.0472 0.0567 0.0660 0.0753 5.60 0.0043 0.0086 0.0129 0.0173 0.0216 0.0260 0.0304 0.0349 0.0394 0.0438 0.0526 1 0.0614 0.0701 5.80 0.0040 0.0080 0.0120 0.0160 0.0201 0.0241 0.02S3 0.0324 0.0365 0.0407 0.0489 j 0.0571 0.0653 6.00 0.0037 0.0074 0.0111 0.0149 0.0186 0.0224 0.0262 0.0301 0.0340 0.0378 0.0455 0.0532 0.0608 6.20 0.0034 0.0069 0.0103 0.0138 0.0173 0.0208 0.0244 0.0280 0.0316 0.0352 0.0424 0.0496 0.0567 6.40 0.0032 0.0064 0.0096 0.0129 0.0161 0.0194 0.0227 0.0261 0.0294 0.0328 0.0395 0.0462 0.0529 6.60 0.0030 0.0060 0.0090 0.0120 0.0150 0.0181 0.0212 0.0243 0.0274 0.0306 0.0369 0.0432 0.0495 6.80 0.0028 0.0056 0.0084 0.0112 0.0140 0.0169 -

0.0198 0.0227 0.0256 0.0286 0.0345 0.0404 0.0463 7.00 0.0026 0.0052 0.0078 0.0104 0.0131 0.0158 0.0185 0.0212 0.0239 0.0267 0.0322 0.0378 0.0433 7.20 0.0024 0.0048 0.0073 0.0098 0.0123 0.0148 0.0173 0.0198 0.0224 0.0250 0.0302 0.0354 0.0406

-+/-7.40 0.0023-0.0045 0.006S

.o.e0092 0.0115 0.0138 0;0162 0.0186 0.02,0.-

0.0234 0.0283 ?0.0332 0.03S 7.60 0.0021 0.0043 0.0064 0.0086 0.0108 0.0130 0.0152 0.0175 0.0197 0.0220 0.0266 0.0312 0.0358 7.80 0.0020 0.0040 0.0060 0.008I 0.0101 0.0122 0.0143 0.0164 0.018S 0.0207 0.0250' 0.0294 0.0337 8.00 0.0019 0.0038 0.0057 0.0076 0.0095 0.0115 0.0134 0.0154 0.0174 0.0195 0.0236 0.0277 0.0318 8.50 0.0016 0.0032 0.0049 0.0066 0.0082 0.0099 0.0116 0.0133 0.0151 0.0168 0.0204 0.0240 0.0275 9.00 0.0014 0.0028 0.0043 0.0057 0.0072 0.0086 0.0101 0.0116 0.0131 0.0147 0.0178 0.0209 0.0240 9.50 0.0012 0.0025 0.0037 0.0050 0.0063 0.0076 0.0089 0.0102 0.0115 0.0129 0.0156 0.0183 0.0211 10.00 0.0011 0.0022 0.0033 0.0044 0.0055 0.0067 0.0078 0.0090 0.0102 0.0114 0.0138 I 0.0162 0.0186

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 73 of 349 Date: 09/2-7/03 Table 6-1Oc. Soil Spectra for M=6.0, Set 3, Higher Vs Soil Profile Per (sec)

I0.1p 03e 0.e I 0.6e l 0.7w 0 9g I

lOP

1.

1.2L 1.4I 1

1.6n.

A 02 A A 0.01 0.1748 0.3253 0.4600 0.5977 0.7539 0.9062 1.0266 1.1231 1.2012 1.2635 1.3581 1.4251 1.4736 0.03 0.1914 0.3569 0.4838 0.6252 0.7848 0.9395 1.0604 1.1561 1.23-26 1.2935 1.3856 1.4504 1.4982 0.04 0.2066 0.3853 0-5183 0.6635 0.8259 0.9821

1. 1027 1.1983 1.2725 1.3310 1.418-7 1.48 I 1.5251

____0.2195 0.4104

~0.5466 0.6937 0:85386 1.0267 1.1507' 1.2511 1.3246 P

Ti8 71 1.4669 1.53~11 1.5728 0.06 0.2538 0.4576 0.6256 03.7905 0.9636 1,1342 1.2613 1.3575 1.4299 1.4888 1.5606 1.6191 1.6551 0.07 0.2809 0.5064 0.6844 0.8661 1.0468 1.2277 1.3591 1.4695 1.5452 1.6011 1.6880 1.7397 1.7715 0.08 0.'2972 0.5311 0.7352 0.9156 1.1182 1.3025 1.4603 1.5698 1.6617 11.7269 1.8049 1.3651 1.3971 0.09 0.3319 0.5882 0.3044 0.9964 1.2050 1.4179 1.5848 1.7136 1.8014 1.8-735 1.9-719 2.0265 2.0596 0.10 0.3498 0.6295 0.8561 1.0647 1.2839 1.5222 1.6970 1.3465 1.9453 2.0280 2.1366 2.1987 2.2359 0.11 0.3655 0.6644 0.9132 1.1436 1.3742 1.6201 1.3088 1.9777 2.0955

-2.1923 2.3209 2.3914 2.4319 0.12 0.388-7 0.7475 0.9756 1.1943 1.4337 1.6960 1.9179 2.1097 2.2405 2.3563 2.4925 2.5697 2.6205 0.13 0.4233 0.7579 11.0181 11.2523 1.5225 1.8076 2.0695 2.2722 2.43-72 2.5560 2.7045 2.8053 2.8637 0.14 0.4319 0.8519 1.1863 1.4578 1.6721 1.8477 2.0671 2.3007 2.4705 2.6079 2.7932 2.9037 2.9781 0.15 0.4148 0.7769 1.1075 1.4313 1.7313 1.9764 2.1215 2.3481 2.5544 2.7165 2.9202 3.0545 3.1382 0.16 0.4832 0.527 1.1911 1.5187 1.8094..

2.0391 2.2353 2.4214 2.5822 2.09 2.9202 3.0923 3.2480 0.17 0.5993 1.1124 1.4872 1.7664 1.980j' 2.1804 2.18 2347 245 17

.17 2 860 0472 0.18

-0.6401 1.1944 J.5992 1.8905 2.1094 2.3617 2.5778 2.7355 2.8446 2.9316 3.0648 3.1700 3.2655 0.19 0.5349 0.9868 1.4818 11.9967 2.3891 2.6250 12.7627 2.8723 2.9687 3.0802 3.2766 3.4420 3.6103 0.20 0.5783 1.0708 1.5783 2.0999 2.5215 2.7741 12.9680 3.1242 3.2477 3.4036 3.7111 3.9917 4.2557 0 21...

~.5930 A 06.74.

.5177

. 2~0247

.512

_.97 4 3.3164 3.6247 3.8126 3.9310 3.9940 3.9407 3.9866 0.22 0.5761 1.0812 1.5038 1.9217 2.3646 2.8334 3.2481 3.5669 3.7838 3.9236 4.0715 4.1012 4.32-20 0.23 0.5070 0.9818 1.3755 1.8149 2.2196 2.5715 2.8847 3.1901 3.4884 3.7799 4.2.699 4.6358 4.9111 0.24 0.4215 0.8582 1.2724 1.6771 2.0766 2.4433 2.7719 3.0-784 3.3776 3.6557 4.1292 4.4914 4,7894 0.25 0.4012 0.8071 1.2001 1.5970 2.0046 2.3863 2.7319 3.0490 3.3509 3.6309 4.1259 4.5173 4,8565 0.26 0.3869 0.7755 1.1517 1.5365 1.9395 12.3171 2.6536 2.9729 3.2784 3.5735 4.0860 4.5105 4.8651 0.27 0.3774 0.7540 1.1181 1.4965 1.8995 2.2923 2.6557 3.0160 3.3779 3.7144 4.2771 4.7142 5.0410 0.28 v0.3590 0.7145 1.0596 1.4192 1.8160 2.2063 2.5676

-2.9105 3.2416 3.5498 4.1014 4.5562 4.9526 0.29 0.3299 0.6544 0.9694 1.3009 1.6744 2.0471 2.3952 2.7314 3.0514 3.3533 3.8905 4.3349 14.7186 0.30 0.3169 0.5928 0.8615 1.1532 1.4912 1.8432 2.1663 2.4639 2.7396 3.0201 3.5130 3.9317 4,2912 0.31 0.3135 0.5817 0.8352 1.1078 1.4235 1.7437 2.0542 2.3249 2.5737 2.7962 3.1931 3.5646 3.9023 0.32 0.3240 0.5963 0.8470 1.1143 1.4217 1.7418 2.0436 2.3156 2.5612 2.7800 3.1720 3.5380 3.8843 0.33 0.3259 0.5962 10.8383 1.0955 1.3934 1.7067 2.0039 2.2778 2.5212 2.7449 3.1325 3.4934 3.8421 0.34 0.3286 0.5939 0.8243 1.0695 1.3542 1.6553 1.9494 2.2167 2.4616 2.6799 3.0546 3.4064 3.7469 0.35 0.3379 0.6066 0.8418 1.0655 1.3176 1.6124 1.9008 2.1738 2.4194-2.6420 3.0260 3.3808 3.7304 0.36 0.3795 0.7224 0.9979 1.2292 1.4943 1.7420 1.9543 2.1371 2.3016 2.4689 2.8575 3.2170 3.5754 0.37 0.4053 0.7699 1.0703 11.3326 1.5710 1.8057 2.0492 2.2687 2.4669 2.6465 2.9459 3.2007 3.4370 0.33 0.4081 0.8045 1.1425 1.4358 1.7094 1.9505 2.1437 2.2910 2.4026 2.5320 2.8515 3.1130 3.3714 0.39 0.3888 0.7751 11.1174 1.4223 1.7113 11.9707 2.1849 2.3547 2.4859 2.5827 2.6841 2.9267 3.1688 0.40 0.3728 0.7541 1.1019 1.4192 1.7209 1.9927 2.2199 2.4026 2.5499 2.54 271

.95 3.1253 0.41 0.3554 0.7274 1.0750 1.3915 1.6955 1.9705 2.2034 2.3950 2.5523 2.6703 2.7982 2.8721 3.1078 0.42 0.3234 0.6670 0.9913 1.2909 1.5791 1.8437 2.1060 2.3380 2.5247 2.6744 2.8769 3.0431 3.2268 0.43 0.2891 0.6002 0.8989 1.2265 1;5714 1.8905 2.1581 2.3674 2.5275 2.6480 2.8017 2.9309 3.1056 0.44 0.2621 0.5486 0.8339 1.1412 1.4577 1.7520 2.0007 2.1927 2.3343 2.4350 2.6022 2.7914 3.0012 0.45 0.2410 0.4914 0.7534 1.0103 1.2720 1.5215 1.7472 1.9482 2.1403 2.3076 2.6364 2.8937 3.1140 0.46 0.2384 0.4868 0.7308 0.9734 1.2237 1.4657 1.6940 1.9120 2.1160 2.3052 2.6202 2.8733 3.0816 0.47 0.2281 0.4670 0.7031 0.9381 1.1805 1.4147 1.6334 1.8381 2.0299 2.2067 2.5082 2.7560 2.9581 0.48 0.2171 0.4454 0.6717 0.8978 1.1308 1.3555 1.5653 1.7624 1.9462 2.1188 12.4206 2.6777 2.8870 0.49 0.2111 0.4344 0.6570 0.8798 1.1113 1.3369 1.5488 1.7485 1.9386 2.1178 2.4392 2.7113 2.9306 0.50 0.2056 0.4256 0.6470 0.8710 1.1057 1.3366 1.5559 1.7653 1.9647 2.1538 2.4930 2.7756 3.0301 0.51 0.1921 0.4013 0.6147 0.8322 1.0624 1.2917 1.5118 1.7214 1.9'216

'2.1105 2.4442 2.7243 3.0011 0.52 0.1840 0.3743 0.5662 0.7616 0.9642 1.1694 1.3745 1.5700 1.7546 1.9260 2.2852 2.6601 3.0038 0.53 0.1795 0.3655 0.5537 0.7465 0.9479 1.1454 1.3346 1.5190 1.7009 1.8805 2.2333 2.3890 2.9141 0.54 0.1716 0.3493 0.5290 0.7140 0.9074 1.0972 1.2798 1.4558 1.6290 1.7993 2.1278 2.4523 2.7571 0.55 0.1656 0.3369 0.5100 0.6881 0.8751 1.0584 1.2348 1.4046 1.5710 1.7334 2.0469 2.3468 2.6434 0.56 0.1621 0.3294 0.4985 0.6724 0.8555 1.0352 1.2083 1.3749 1.5380 1.6969 2.0038 2.2915 2.5796 0.57 0.1605 0.3263 0.4935 0.6657 0.8478 1.0'273 1.2001 1.3674 1.5307 L.6901 1.9997 2.2928 2.5649 0.58 0.1582 0.3-216 0.4865 0.6573 0.8380 1.0179 1.1914 1.3600 1.5245 1.6866 1.9997 2.3011 2.5807 0.60 0.1457 0.2966 0.4493 0.6082 0.7780 0.9482 1.1139 1.2753 1.4332 1.5884 1.8896 2.1797 2.4508 0.62 0.1394 0.2834 0.4288 0.5803 0.7431 0.9077 1.0684 1.2265 1.3808 1.5327 1.8293 2.1178 2.3896 0.64 0.1315 0.2652 0.40 :1

0. 4 2 0 6 7

. 5 8 1.0115 1.1667 1.3194 1.4707 1.7688 2.06 3 2 4 8 L0.66 10.1341 0.2604 03733 10.4795 0.6142 0.7559 0.8992 1.0432 1.1864 1.3284 1.6121 1.894 21696

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 74 of 3 49

______D ate: 08/27/03 0.68 0.1299 0.2586 10.3801 0.4982 0~6165 0.7289 0.8334 0.9317

-1.0250 1.3ll

!.3941 11.6556 )1.9136 0.70 0.1445 0.2771 0.3933 0.5023 0.6252 0.7430 [0.8540*

0.9599 [1.0615 1597 1L.3S07 1.5472 11.7450 0.72 0.1523 0.2934 0.4182 0.5348 0.6488 0.7575 [0.8609 0.9637 1.0666 1.17031 1.3763 1.3805 J1.7814 0.74 0.1501 0.2911 0.4171 0.5355 0.6507

-0.7 593 [0.8611 0.9606 J1.0595 1.1586 1-.3559 1.5519 I1.7441 0.76 0.1447 0.2848 0.4141 0.5385 0.6628.0.7838 0.8998 1.0123 1.1216 1.2282 1.4342 1.6343 1.8258 0.78 0.1534 0.3022 0.4403 0.5733 0.7037 0.8334 j0.9556 1.0746 1.1908 1.3049 1.5274 1.7453 I 1. 9 i5.8 0.80 0.4539

  • 0.3032 0.4426

-0.57-76 0.7121 0.8412

-0.9643 1.0842.JIM L21 1.3174.

1.5449 1.7697 1.9885 0.82 0.1627 0.3162 0.4523 0.5793 0.7022 0.8156 0.9357 1.0526 1.1671 1.2802 1.5036 1.7259 1.9438 0.84 0.1689 0.3288 0.4714 0.6053 0.7358 0.8556 0.9698 1.0803 1.1834 1.2804 1.4581 1.6499 1.8611 0.86 0.1668 0.3251 0.4667 0.6006 0.73-26 0.8677 0.9938 1.1127 1.2250 11.3315 1.5291 1.7085 1.8710 0.88 0.1594 0.3112 0.4473 0.5856 0.7-268 0.8641 0.9938 1.1174 1.2352 1.3478 1.5589 1.7530 1.9301 0.90 0.1498 0.2971 0.4376 0.5752 0.7143 0.8507 0.9812 1.1066 1.227 3 1.3436 1.5629 1.7668 11.9542 0.92 0.1477 0.2921 0.4311 0.5672 0.7031 0.8366 0.9657 1.0907 1.2120 1.3294 1.5525 1.7617 1.9554 0.94 0.1450 0.2878 0.4253 0.5600 0.6937 0.8245 0.9511 11.0745 1.1947 1.3117 1.5351 1.7461 1.9423 0.96 0.1427 0.2833 0.4189 0.5519 0.6838 0.8125 0.9371 1.0587

1. 1772 1.2929 1.5147 1.1.7253 1.9221 0.98 0.1402 0.2783 0.4117 0.5429 0.6729 0.7999 0.9226 1.0421 1.1588 1.2730 1.4925 1.7010 1.8970 1.00 0.1373 0.2766 0.4128 0.5453 0.6753 0.7980 0.9089 1.0232 1.1381 1.2503 1.4664 1.72 1.8669 1.05 0.1336 0.2700 0.4043 0.5363 0.6677 0.7937 0.9099 1.0157 1.1115 1.1979 1.3819 1500 1.7674 1.10 0.1210" ~436 0.3644 0.488-3 0.6119

.0.73317 -0.8515 0.9642' 1.071,6 1.1757

-i.3-750W4'

.55 1.7162 1.15 0.1199 0.2454 0.3735 0.5018 0.6303 0.75.79 0.8818 1.0004 1.1133 1.2202 1.4155 1.5942 1.7656 1.20 0.1169 0.2405 0.3669 0.4937 0.6213-0.7484 0.8720 0.9907 I'1033 1.2103 1.4184 1.6177 1.7976 1.25 0.1041 0.2151 0.3300 0.4473 0.5672 0.6875 0.8067 0.9237 1.0379 1.1492 1.3618 1.5597 1.7398 1.30 0.0921 0.1883 0.2880 0.3920 0.4990 0.6076 0.7158 0.8226 0.9271 1.0293 1.2262 1.4120 1.5842 1.35 0.0812 0.1660 0.2529 0.3411 0.4307 0.5207 0.6104 0.6993 0.7899 0.8814 1.0634 1.2427 1.4130 1.40 0.0707 0.1445 0.2204 0.2976 0.3763 0.4556 0.5404 0.6299 0.7213' 0.8139 1.0005 1.1847 1.3597 1.45 0.0617

0. 1264 0.1945 0.2659 0.3386 0.4136 10.4910 10.5694 0.6481 0.7270 0.8840 1.0383 11.1881 1.50 0.0572 0.1177 0.1827 0.2501 0.3187 0.3896 0.4628 10.5372 0.6123 0.6877 0.8384 0.9874 11.1328 1.5$

0.0545 0.1112 0.1715 0.2351 0.3003 0.3678 0.4376 10.5089 0.5811 0.6538 0.7994 0.9436 1.0843 1.60 0.0520 0.1062 0.1620 0.2203 0.2824 0.3469 0.4137 0.4819 10.5510 0.6204 0.7598 0.8977 1.0324 1.65 0.0497 0.1014 0.1546 0.2088 0.2647 0.3257 0.3889 0.4533 0.5186 0.5844 0.7161 0.8466 0.9739 1.70 0.0474 0.0967 0.1476 0.1994 0.2520 0.3052 0.3627 0.4231 0.4844 0.5460 0.6694 0.7918 0.9114 1.75 0.0453 0.0924 10.1410 0.1906 0.2411 0.2922 0.46 0.3951 0.4495 0.3069 0.6219 0.7363 0.48 1.80 0.0434 0.0886 0.1352 0.1828 0.2313 0.2804 0.3298 0.3794 -0.4289 0.4783 0.5764 0.6821 0~86 1.85 0.0417 0.0851 0.1299 0.1757 0.2225 0.2698 0.3175 0.3653 0.4131 0.4608 0.5558 0.6497 074jj6 1.90 0.0402 0.0820 0.1251 0.1693 0.2144 0.2602 0.3064 0.3526 0.3990 0.4452 0.5375.

0.6290 0.71901 1.95 0.0388 0.0790 0.1206 0.1632 0.2068 0.2512 0.2959 -0.3408 10.3858 0.4309 0.5209 0.6104 0.6986 2.00 0.0374 0.0761 0.1162 0.1573 0.1994 0.2424 0.2858 0.3294 10.3732 0.4170 0.5049 0.5926 0.6791 2.05 0.0359 0.0732 0.1118 0.1513 0.1920 0.2335 0.2755 0.3178 0.3604 10.4031 0.4888 0.5745 0.6593 2.10 0.0345 0.0702 0.1072 0.1451 0.1843 0.2243 0.649

-0.3059 0.3471 10.3886 0.4719 0.5554 0.6381 2.15 0.0329 0.0670 0.1024 0.1387 0.1762 0.2147 0.2538 0.2933 0.3331 10.3731 0.4538 0.5347 0.6150 2.20 0.0313 0.0637 0.0974 0.1320 0.1678 0.2046 0.2420 0.2799 0.3182 10.3567 0.4343 0.5125 0.5902 2.25 0.0296 0.0603 0.0922 0.1250 0.1590 0.1940 10.2298 10.2659 0.3025 0.3393 0.4137 0.4887 0.5635 2.30 0.0278 0.0568 0.0868 0.1178 0.1500 0.1831 0.2170 0.2514 0.2861 0.3212 0.3921 10.4637 10.5354 2.35 0.0261 0.0532 0.0814 0.1105 0.1408 0.1720 0.2040 0.2364 0.2693 0.3025 0.3698 10.4380 10.5064 2.40 0.0243 0.0496 0.0760 0.1032 0.1315 0.1608 0.1908 0.2213 0.2523 0.2836 0.3472 0.41 19 10.4770 2.50 0.0209 0.0427 0.0657 0.0893.

0.1134 0.1387 0.1649 0.1916 0.2188 0.2464 10.3029 0.3608 10.4194 2.60 0.0190

.0.0382 0.0574 0.0769 0.0979 0.1194 0.1418 0.1649 0.1885 0.2126 10.2624 0.3136 0.3657 2.70 0.0180 0.0362 0.0545 0.0729 0.0917 0.1107 0.1297 0.1487 0.1677 0.1867 10.2260 0.2708 0.3166 2.80 0.0169 0.0341 0.0513 0.0687 0.0865 0.1044 0.1224 0.1405 0.1585 0.1766 10.2128 0.2493 0.2860 2.90 0.0159 0.0320 0.0483 0.0646 0.0812 0.0981 0.1151-0.1322 0.1493 0.1664 10.2009 0.2356 0.2705 3.00 0.0150 0.0301 0.0454 0.0608 0.0763 0.0921 0.1081 0.12.42 0.1404-0.1566 0.1893.

0.2223 0.2554 3.10 0.0141 0.0284 0.0428 0.0573 0.0719 0.0866 0.1016 0.1168 0.1321 0.1475 0.1785 0.2098 0.2412 3.20 0.0133 0.0267 0.0403 0.0540-0.0677 0.0817 0.0958 0.1101 0.1245 0.1391 0.1685 0.1981 0.2279 3.30 0.0125 0.0252 0.0381 0.0510 0.0640 0.0771 0.0905 0.1040 0.1177 0.1314 0.1593 0.1874 0.2155 3.40 0.0118 0.0238 0.0360 0.0483 0.0606 0.0730 0.0857 0.0985 0.1114 0.1244 0.1508 0.1775 0.2042 3.50 0.0112 0.0226 0.0341 0.0458 0.0575 0.0693 0.0813 0.0934 0.1057 0.1180 0.1431 0.1683 0.1937 3.60 0.0106 0.0214 0.0324 0.0435 0.0547 0.0659 0.0773 0.0888 0.1004

0. 11.22 0.1359 0.1599 0.1840 3.70 0.0101 0.0204 0.0308 0.0414 0.0520 0.0627 0.0735 0.0845 10.0955 10.1067 0.1292 0.1520 0.1749 3.80 0.0096 0.0194 0.0293 0.0394 0.0495 10.0597 0.0701 0.0805 0.0910 0.1016 0.1230 0.1447 0.1664 3.90 0.0091 0.0184 0.0279 0.0375 0.0472 0.0569 0.0668 0.0767 0.0867 0.0967 0.1171 0.1377 0.1585 4.00 0.0087 0.0175 0.0266 0.0357 0.0449 0.0542 0.06.36 0.0730 0.0826 0.0921 0.1115 0.1311 0.1509 4.10 0.0083 0.0167 0.0253 0.0340 0.0428 0.0516 0.0606 0.0696 0.0786 0.0877 0.1062 J0.1249 0.1437 4.20 0.0078 0.0158 0.0240 0.0323 0.0407 0.0491 0.0577 0.0662 0.0748 0.0835 0.1011 0.1189 0.1369 4.30 0.0075 0.0150 0.028 0.0307 0.0387 0.0467 0.0548 10.0630 0.0712 0.0795 0.0962 0.1132 0.1303 4.40 0.0071 I0.0143 0.0217 0.0292 0.0367 0.0444 0.0521

- 0.0599 0.0677 0.0756 0.0915 j0.1077 0.1241

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 75 of 349 Date: 08/27/03 4.50 l0.0067 0.0135 0.0205 0.0277 0.0349 0.0421 0.0495 0.0569 0.0643 0.0718 0.0870 0.1025 0.1181 4.60 0.0064 0.0128 0.0195 0.0262 0.0331 0.0400 0.0470 0.0540 0.0611 0.0682 0.0827 0.0974 0.1123 4.70 0.0060 0.0122 0.0184 0.0248 0.0313 0.0379 0.0445 0.0512 0.0580 0.0648 0.0786 0.0926 0.1068 4.80 0.0057 0.0115 0.0174 0.0235 0.0297 0.0359 0.0422 0.0486 0.0550 0.0615 0.0746 0.0880 0.1015 4.90 0.0054 0.0109 0.0165 0.0222 0.0281 0.0340 0.0400 0.0460 0.0521 0.0583 0.0709 0.0836 0.0965 5.00 0.0051 0.0103 0.0156 0.0210 0.0265 0.0321 0.0378 0.0436 0.0494 0.0553 0.0672 0.0794 0.0917 5.10.

0.0048 0.0097.. r,0.0147 - 0.0199

. 0.0251 0.0304 0.0358

.0.0413 0.0468 0.0524 0.0638 0.0754..

0.0871 5.20 0.0046 0.0092 0.0139 0.0188 0.0237 0.0287 0.0339 0.0391 0.0443 0.0497 0.0605 0.0715 0.0827 5.40 0.0041 0.0082 0.0124 0.0168 0.0212 0.0257 0.0303 0.0350 0.0398 0.0446 0.0544 0.0644 0.0745 5.60 0.0036 0.0073 0.0111 0.0150 0.0189 0.0230 0.0271 0.0314 0.0357 0.0400 0.0489 0.0580 0.0671 5.80 0.0032 0.0066 0.0099 0.0134 0.0169 0.0206 0.0243 0.0281 0.0320 0.0360 0.0440 0.0522 0.0604 6.00 0.0029 0.0059 0.0089 0.0120 0.0152 0.0185 0.0218 0.0253 0.0288 0.0324 0.0397 0.0471 0.0545 6.20 0.0028 0.0056 0.0084 0.0113 0.0143 0.0173 0.0204 0.0236 0.0267 0.0299 0.0364 0.0428 0.0493 6.40 0.0026 0.0053 0.0080 0.0107 0.0135 0.0163 0.0193 0.0223 0.0253 0.0284 0.0347 0.0411 0.0474 6.60 0.0024 0.0048 0.0073 0.0097 0.0123 0.0148 0.0175 0.0202 0.0230 0.0259 0.0317 0.0377 0.0436 6.80 0.0022 0.0043 0.0065 0.0087 0.0109 0.0130 0.0153 0.0177 0.0202 0.0227 0.0279 0.0332 0.0385 7.00 0.0021 0.0041 0.0062 0.0082 0.0102 0.0121 0.0141 0.0160 0.0179 0.0198 0.0241 0.0287 0.0332 7.20 0.0019 0.0038 0.0057 0.0075 0.0093 0.0112 0.0130 0.0148 0.0165 0.0183 0.0220 0.0261 0.0303 7.40

.0.0017 0,0034 ' 0.-0050 0.0067 0.0083 0.0100 0.0116. 1-0-0132 0.0147 0.0164 0.0201 O.0239 0.0277 7.60 0.0015 0.0029 0.0043 0.0058 0.0072 0.0086 0.0101 0.0118 0.0134 0.0151 0.0185 0.0219 0.0254 7.80' 0.0014 0.0028 0.0041 0.0055 0.0069 0.0083 0.0097 0.0110 0.0124 0.0139 0.0170 0.0201 0.0233 8.00 0.0013 0.0026 0.0039 0.0052 0.0065 0.0078 0.0091 0.0104 0.0116 0.0129 0.0157 0.0186 0.0215 8.50 0.0011 0.0022 0.0034 0.0045 0.0057 0.0068 0.0080 0.0091 0.0102 0.0113 0.0134 0.0154 0.0178 9.00 0.0010 0.0019 0.0030 0.0040 0.0050 0.0060 0.0070 0.0079 0.0089 0.0098 0.0116 0.0133 0.0150 9.50 0.0008 0.0017 0.0025 0.0034 0.0043 0.0051 0.0060 0.0068 0.0076 0.0084 0.0101 0.0119 0.0136 10.00 0.0007 1 0.0015 0.0022 0.0030 0.0037 0.0045 0.0052 [ 0.0060 0.0068 0.0076 0.0092 0.0108 0.0123

Caic Number: GEO.HBI[P.033.02 Rev Number: 0 Sheet Number: 76 of 3 49 Date: 08127/03)

Table 6-11Ia. Soil Spectra for M=7.0, Set 1, Higher Vs SoilProfile Perj 1 g.6 (sec) 0.1g8 0.2e 0.3e 0.4"R 0.5c 0.6e 0.7g 0.8 L

0.9g 1.Oz LIZg 1___4_

1____

0.01 0.1885 0.3452 0.480 0.5869 0.6696 0.7462 0.8199 0.8870 10.9439 0.9872 11.0859 1.1802 1.2580 0.03 0.1919 0.3509 0.4884 0.5964 0.6804 0.7573 0.8314~

0.8985 [ 0.9555 0.9989 1.0973 1.1914 1.2686 0.04 0.2000 0.3608 0.4986 0.6070 0.6911 0.7686 j0.8426 0.9104 0.9672 1.0103 1.1083 1.2020 1.2786 0.05 0.278-5' 0.3847 0.52S9:

0.6328 0.7174 0O.7918 {0.8643 -0.93114 0.9867 1.0286- ['.1 2-29 1.21-73 < 1;2927 0.06 0.2598 0.3974 0.5412 0.654 0.7371 0.8151 0.8894 0.9555 1.0105 1.0515 1.1455 1.2382 1.3117 0.07 0.2703 0.4182 0.5136 0.6213 0.7114 0.7975 0.8791 0.9511 1.0108 1.0558 1.1576 1.2529 1.3291 0.08 0.3130 0.5016 0.6836 0.81 9 0.8945 0.9657 1.02'70 1.0837 1.1312 1.1637 1.2462 1.3263 1.3S74 0.09 0.3578 0.5129 0.6693 0.8032 0.8928 0.9655 1.0329 1.094-7 1.1449 1.1784 1.2629 1.3467 1.4130 0.10 0.4002 0.6159 0.7647 0.8677 0.9812 1.0446 1.1012 1.1478 1.1875 1.2172 1.2656 1.3503 11.4258 0.11 0.4211 0.6757 0.8572 1.0252 1.1458 1.2199 1.2803 1.3281 11.3668 11.3933 1.4357 11.4601 11.4682 0.12 0.4702 0.7818 0.9655

1. 0853 1.2196 1.3150 1.3836 1.4441 11.4905 11.5240 1.5680 11.5964 11.5924 0.13 0.4374 0.7241 0.9705 1.1725 1.3325 1.4414 1.5321 1.5991 11.6504 11.6867 1.7371 1.7581 1.7431 0.14 0.4394 0.7856 1'.0581 1.2906 1.4732 1.6084 1.7098 1.7884 11.8468 11.8879 1.9392 1.9595 11.9353 0.15 0.43 17 0.7819 1.0641 1.3125 1.5194 1.6741 1.7922 1.8804 11.9465 1.9944 2.0589 2.0859 12.0622 0.16 0.4950 0.8596 1.0799 1.3050 1.5292 1.6958 1.8255 1.9228 2.0003 2.0591 2.1463 2.1747 12.15 18I 0.17 0.5445 0.8835 1.1398

'T1:309 1.4655 1L5354 1.5902 1.6960 1.7824 1.8505' 1.9466 1.9826 1+969U&.

0.18 0.5687 1.0317 1.2760 1.4734 1.6127 1.6995 1.7656 1.8117 1.8375 1.8334 1.9183 1.9598 11.9577 0.19 0.5644 0.9972 1.3057 1.5185 1.6543 1.742 1.7494 1.7402 1.7652 1.8330 1.9277 1.9753 11.9798 0.20 0.5692 1.0247 1.3531 1.5740 1.7355 1.8308 1.8639 1.8468 1.8241 1.8932 1.9930 2.1333 12.1357 0.21 0.5865 1.0595 1.4160 1.7534 1.9622 2.0835 2.1421 12.1774 2.2120 2.2477 2.3396 2.3448 12.2563 0.22 0.5755 1.0627 1.4363 1.8539 2.2236 2.4294 2.5191 2.5346 2.5226 2.5008 2.5062 2.5100 12.4877 0.23 0.5535 1.0572 1.5436 1.9315 2.2044 2.4007 2.5370 2.6417 2.6892

'2.6860 2.72.28 2.7306 12.6833 0.24 0.5129 1.0169 1.5092 1.9183 2.2187 2.4413 2.6241 2.7526 2.8407 2.8128 12.8817 2.8067 12.7273 0.25 0.4710 0.9845 1.4961 1.9212 2.2739 2.5342 2.7334, 2.8717 2.9784 3.0362 13.0624 2.9915 12.8730 0.26 0.4359 0.8983 1.4074 11.9185 2.3685 2.7114 2.9521 3.1220 3.2365 3.2991 13.3045 3.2833 13.1390 0.27 0.3582 0.7605 1.2052 1.6514 2.0555 2.3691 2.604 2.8020 12.9694 3.1028 13.3189 3.3466 13.263 0.28 0.3503 0.6620 0.9693 1.2974 1.6460 12.0106 2.3484 12.6403 12.8729 3.0611 13.3884 3.6249 13.7237 0.29 0.3427 0.6532 0.9656 1.2884 1.6255 11.9657 2.2778 12.5321 12.7335 2.8897 13.2585 3.5303 3.6718 0.30 0.3341 0.6211 0.8950 1.1730 1.4652 11.7525 2.0098 12.2174 12.4304 2.6635 13.0134 3.3213 13.4776 0.31 0.3357 0.6188 0.8945 1.1717 1.4093 1.6680 1.9070 12.1791 12.4711 2.7608 3.3241 3.7216 3.9070 0.32 0.3678 0.6153 0.8825 1.1119 1.3122 1.6356 1.8792 12.1528 12.4492 12.7458 3.3353 3.7592 3.9622 0.33 0.400-7 0.6789 0.8505 1.0675 1.3074 1.5642 1.8029 12.0163 12.2019 2.4029 2.9912 3.4833 3.7962 0.34 0.4158 0.7191 0.9362 1.0630 1.2199 1.4607 1.6897 11.8916 12.0681 12.2237 2.6292 3.0941 3.4016 0.35 0.4236 0.7436 0.9874 1.1408 1.2443 1,4126 1.5981 11.7925 1.9651 12.1170 2.4263 2.8095 3.2141 0.36 0.4075 0.7246 0.9834 1.1708 1.3669 1.5516 1.7196 11.8644 1.9798 12.0630 12.3 198 2.7145 3.0735 0.37 0.3914 0.7206 0.9984 1.2394 1.4518 11.6542 1.8440 12.0098 2.1480 12.2545 12.5009 12.7649 13.0144 0.38 0.3915 0.7177 0.9968 1.2449 1.4678 11.6818 1.8847 12.0666 2.2217 2.3457 12.6289 2.9234 3.1940 0.39 0.3705 0.6783 0.9491 1.1984 1.4242 1.6438 1.8520 12.0401 27.2038 2.3378 12.6380 12930 1.21 0.40 0.3378 0.6218 1 0.9073 1.1298 1.3568 1.5743 1.7823 11.9713 2.1364 2.2727 12.5705 32.710 13.365 0.41 0.3306 0.6831 10.9859 1.1746 1.3155 1.5309.

1.7344 11.9197 12.0813 2.2148 12.5056 1274 305 0.42 0.3430 0.7042 11.0130 1.2037 1.3305 1.5456 1.7462 11.9289 12.0880 2.2187 12.5046 1277 301 0.43 0.3370 0.6911 0.9956 1.1919 1.3978 1.5919 1.7940 1.9765 12. 1359 2.2669 12.5583 12.8462 13.0938 0.44 0.3089 0.6356 0.9708 1.2719 1.4816 1.6412 1.8252 2.0094 12.1716 12.3056 12.6049 2.90'21 3.1589 0.45 0.3071 0.6198 0.9813 1.2794 1.4823 11.6309 1.8179 2.0025 12.1664 12.3029 12.6070 2.9101 3.1733 0.46 0.3002 0.5943 0.9296 1.2070 1.3914 1.5847 1.7811 1.9635 12.1272 12.2651 12.5690 2.8722 3.1367 0.47 0.2909 0.5771 0.8589 1.1173 1.3393 1.5429 1.7355 1.9149 12.0768 12.2145 2.5152 12.8145 3.0758 0.48 0.2815 0.5594 0.8331 1.0860 1.3048 1.5056 1.6947 1.8714 12.0315 2.1681 2.4643 2.7577 3.0136 0.49 0.2730 0.5435 10.8109 1.0601 1.2771 1.4758 1.6622 1.8363 11.9944 2.1302 2.42 14 2.7082 2.9577 0.50 0.2653 0.5298 0.7921 1.0382 1.2543 1.4512 1.6353 1.8068 1.9629 2.0979 2.3840 2.6639 2.9081 0.51 0.2585 0.5174 0.7753 1.0186 1.2339 1.4290 1.6110 1.7801 1.9348 2.0685 2.3496 2.6227 2.8617 0.52 0.2523 0.5063 0.7598 1.0005 1.2143 1.4088 1.5887 1.7561 1.9088 2.0411 12.3172 2.5855 12.8177 0.53 0.2469 0.4963 0.7457 0.9841 1.1970 1.3894 1.5680 11.7333 1.8844 2.0162 12.2885 12.5502 12.7785 0.54 0.2422 0.4873 0.7331 0.9688 1.1800 1.3715 1.5485 1.7125 1.8621 1.9925 2.2612 2.5190 12.74 171 0.55 0.2380 0.4793 0.7214 0.9541 1.1637 1.3540 1.5296 1.6923 1.8409 11.9708 2.2359 2.4893 12.7071 0.56 0.2343 0.4719 0.7102 0.9401 1.1480 1.3369 1.5113 1.6727 1.8204 11.9498 2.2123 2.4616 12.6761 0.57 0.2310 0.4649 0.6998 0.9268 1.1329 1.3203 1.4937 1.6542 1.8011 11.9301 2.1904 2.4363 12.6476 0.58 0.2278 0.4583 0.6898 0.9142 1.1185 1.3045 1.4771 1.6369 1.7831 1.9118 2.1703 2.4132 2.6215 0.60 0.2216 0.4453 0.6702 0.8891 1.0898 1.2740 1.4444 1.6024 1.7476 1.8757 2.1299 2.3676 2.5697 0.62 0.2147 0.4313 0.6493 0.8621 1.0584 1.2388 1.4068 1.5627 1.7056 1.8319 2.1259 2.4190 2.6259 0.64 0.207 0.4170 0.27 0.8338 1.0248 1.2008 f1.3655 1.5181 1.6580 1.7821 2.0891 2.3905 2.6108 0.66 0.2019 0.4053 0.6098 0.8103 0.9967 1.1693 1.3309 1.4811 1.6192 1.7422 1.9827 2.2718 2.4993

Calc Number: GEO.H-BIP.03.02 Rev Number: 0 Sheet Number: 77 of' 349

_____D ate: 0 8/2 7/0 3 0.68 J0.1979 0.3968 30.5970 0.7935 J0.9770 1.1479 1.3080 31.4576 1.5955 1.7192 1.9602

2. 1834 12.3764 0.70 J0.1944 0.3896 J0.5863 0.7798 j0.9613 1.1311 1.290-7 1.4406 1.5-792

-1.7041 1.9471 2.1-710 12.3636 0.72 0.1901 [0.3813 J0.5740 0.7643 0.9436 1.1121 1.2711 1.4-208 1.5597 1.6853 1.9293 2.1536 2.3477 0.74 0.1851 0.3715 0.5598 0.7462 0.9226 1.0890 1.2466-1.3955 1.5338 1.6592 1.9026 2.1256 2.3 1 8 0.76 0.1837 0.3614 0.5450 0.7272 [0.9003 1.0642 1.2199 1.3674 1.5047 1.6295 1.8710 2.0919 2.28.34 0.78 0.1839 0.3517 0.5307 0.7089 [0.8788 1.0400 1.1937 1.3397 -1.4758 1.6000 1.8394 2.0581 2.'2480O 0.80 0.1844 0.3510 0.5173..

0.6916.1. 0.8583 1.0170 1.1690 11.3133,-148 1.5-719 11.8093 2.0264 2.2152 0.82 0.1850 0.3538 0.5105 0.6750 0.8385 0.9948 1.1450 1.2877 11.4217 1.5446 11.7803 1.9958 2.1834 0.84 0.1854 0.3560 0.5148 0.6647 0.8197 0.9736 1.1218 1.2630 { 1.3959 1.5182 11.7523 1.9660 2.1523 0.86 0.1856 0.3575 0.5182 0.6693 0.8089 0.9539 1.1002 1.2399 11.3718 1.4935 11.7268 1.9381 2.1233 0.88 0.1854 0.3586 0.5209 0.6734 0.8132 0.9475 1.0819 1.2195 11.3507 1.4787 11.7154 1.9201 2.0990 0.90 0.1851 0.3591 0.5228 0.6766 0.8172 0.9508 1.0832 1.2155 11.3464 1.4720 11.7057 1.9088 2.0853 0.92 0.1846 0.3588 10.5237 0.6-787 0.8199 0.9533 11.0844 1.2143 1.3427 1.4658 11.6963 1.8975 2.0734 0.94 0.1834 0.3573 0.5225 0.6783 0.8201 0.9536 1.0837 1.2116 1.3374 1.4581 11.6851 1.8842 2.0589 0.96 0.1812 0.3539 0.5188 0.6747 0.8170 0.9302 1.0794 1.2056 1.3292 1.4474 11.6703 1.8664 2.0393 0.98 0.1780 0.3484 0.5122 0.6679 0.8102 0.9434 1.0716 1.1962 1.3176 1.4334 11.6519 1.8443 2.0148 1.00 0.1736 0.3411 0.5032 0.6583 0.8008 0.9338 1.0614 1.1847 1.3042 1.4178 11.6319 1.8199 1.9869 1.05 0.1786 0.3548 0.5205 0.6722 0.7996 0.9067 1.0300 1.1515 1.2680 1.3779 1.5838 1.7626 1.9197 A.;.I.0 0.1685.

0.33,62 0.4951

.0.6484 0.7796 10.8898 0.9963 1.1172 11.2320.

1.3408 1.5425 1.1J.7175 1.8691 1.15 0.1445 0.2955 0.4497 0.6064 0.7572 0.896 1.0285 1.1483 1.2554 1.3451 1.5222 1.6909 1.8402 1.20 0.1370 0.2896 0.4494 0.6113 0.7679 0.9138 1.0502 1.1757

-1.2887 1.3893 1.5927 1-7520 1.8670 1.25 0.1278 0.2714 0.4241 0.5807 0.7333 0.8762 1.0101 1.1463 1.2782 1.4015 1.6211 J1.8002 1.93988 1.30 0.1172 0.2433 0.3813 0.5274 0.6761 0.8217 0.9646 1.1043 1.2397 1.3690 1.6034 1.8000 1.9571 1.35 0.1058 0.2184 0.3443 0.4799 0.6227 0.7657 0.9075 1.0467 1.1819 1.3109 1.5446 1.7417 1.9012 1.40 0.0963, 0.2053 0.322-7 0.4480 0.5807 0.7142 0.8465 0.9763 1.1024 1.2227 1.4414 1.6274 1.7798 1.45 0.0889 0.1893 0.2967 0.4106 0.5308 0.6517 0.7718 0.8897 11.0043 1.1139 1.3140 1.4862 1.6294 1.50 0.0800

-0.1703 0.2672 0.3696 0.4773 0.5860 0.6942 0.8009 10.9049 1.0049 1.1889 1.3607 11.5194 1.55 0.0741 0.1586 0.2484 0.3426 0.4-409 0.5404 0.6403 0.7403 0.8394 0.9369 1.1219 1.2975 11.4980 1.60 0.0725 0.1514 0.2361 0.3255 0.4208 0.5209 0.6249 0.7330 0.8451 0.9620 1.1968 1.4268 1.6380 1.65 0.0695 0.1462 0.2286 0.3171 0.4123 0.5120 0.6160 0.7242 0.8364 0.9534 1.1868 1.4131 1.6197 1.70 0.0650 0.1384 0.2171 0.2995 0.3858 0.4738 0.5629 0.6527 0.7476 0.8544 1.0670 1.2731 1.4616 1.75 0.0623 0.1326 0.2082 0.2877 0.3709 0.4560 0.5424 0.6299 0.71789 0.8060 0.9780 1.1431 1.3191 1.80 0.0593 0.1263 0.1987 0.2749 0.3550 0.4369 0.5204 0.6052 10.6907 0.7768 10.9454 j1.1082 1.2824 1.85 0.0563 0.1193 0.1880 0.2607 0.3372 0.4156 0.4957 0.5772 0.6598 0.7432 I0.9073 1.0665 1.2453 1.90 0.0548 0.1116 0.1762 0.2451 0.3176 0.3921 0.4683 0.5461 0.6251 0.7054 0.8638 j1.0185 11.1905 1.95 0.053 1 0.1073 0.1637 0.2283 0.2966 0.3668 0.4387 0.5124 0.5876 0.6644 0.8166 0.9665 11.1142 2.0 0.0512 0.1036 0.1564 0.2107 0.274-7 0.3405 0.4081 0.4775 0.5487 0.6220 0.7684 0.9149 11.0622 2.05 0.0491 10.0997 0.1507 0.2019 0.2532 0.3141 0.3775 0.4429 0.5106 0.5816 0.7245 0.8683 11.0129 2.10 0.0470 0.956 0.1447 0.1943 0.2440 0.2938 0.3487 0.4116 0.4772 10.5461 0.6840 j0.8227 10.9623 2.15 0.0449 0.0914 0.1387 0.1865 0.2348 0.2831 0.3316 0.3839 0.4464 0.5121 10.6435 f0.7761 10.9100 2.20 0.0427 0.0872 0.1326 0.1790 0.2258 0.2726 0.3 195 0.3667 0.4161 0.4782 10.6028 0.7289 0.8566 2.25 0.0406 0.083 1 0.1268 0.1716 0.2170 0.2622 0.3075 0.3531 0.3989 0.4453 0.5622 0.6818

0. 803 5 2.30 0.0386 0.0792 0.1213 0.1645 0.2083 0.2520 0.2958 0.3398 0.3840 0.4287 0.5225 0.6356 0.7516 2.35 0.0367 0.0755 0.1160 0.1576 0.1999 0.2421 0.2843 0.3268 0.3696 0.4127 0.4989 0.5913 0.7019 2.40 0.0349 0.0720 0.1110 0.1510 0.1917 0.2324 0.2733 0.3143 0.3556 0.3974 0.4807 0.5636 0.6550 2.50 0.0317 0.658 0.1016 0.1386 0.1764 10.2143 0.2525.

0.2908 0.3295 0.3687 0.4469 0.5250 10.6030 2.60 0.0289 0.0602 0.093 1 0.1273 0.1624 0.1978 10.2334 0.2695 0.3059 0.3428 0.4167 0,4906 10.5646 2.70 0.0264 0.0550 0.0853 0.1169 0.1496 0.1826 0.2161 0.2500 0.2844 0.3195 0.3895 0.4596 0.5297 2.80 0.0241 0.0504 0.0782

0. 1075 0.1378 0.1687 0.2002 0.2323 0.2649 0.2981 0.3643 0.4307 0.4972 2.90 0.0220 0.0461 0.0717 0.0987 0.1269 0.1560 0.1857 0.2160 0.2468 0.2781 0.3407 0.4035 0.4664 3.00 0.0201 0.0420 0.0656 0.0905 0.1169 0.1443 0.1722 0.2007 0.2297 0.2592 0.3181 0.3774 0.4370 3.10 0.0182 0.0383 0.0599 0.0831 0.1078 10.1334 0.1596 0.1862.0.2134 0.2411 0.2965 0.3524 0.4087 3.20 0.0166 0.0349 0.0549 0.0763 0.0994 0.1232 0.1476 10.1725 0.1979 0.2239 0.2759 0.3284 0.3816 3.30 0.0152 0.0320 0.0503 0.0701 0.0914 0.1135 0.1362 0.1594 0.1831 0.2074 0.2561 10.3055 0.3556 3.40 0.0142 0.0293 0.0461 0.0643 0.0840 10.1044 0.1254 0.1470 0.1691 0.1918 0.2373 0.2837 0.3309 3.50 0.0141 0.0286 0.0434 0.0588 0.0769 0.0958 0.1153 0.1353 0.1559 0.1770 10.2195 0.2630 0.3075 3.60 0O.0 133 0.0271 0.0414 0.0559 0.0708 0.0878 0.1058 0.1244 0.1434 0.1631 10.2028 0.2435 0.2856 3.70 0.0126 0.0251 0.0376 0.0510 0.0649 0.0804 0.0970 0.1142 0.1318 0.1501 0.1872 0.2254 0.2651 3.80 0.0125 0.0249 0.0371 0.0492 0.0612 0.0734 0.0888 0.1046 0.1210 0.1380 0.1726 0.2085 0.2460 3.90 0.0121 0.0242 0.0362 0.0481 0.0600 0.0718 0.0836 10.0959 0.1110 0.1268.

0.1592 0.1930 10.2282 4.00 0.0116 0.0232.0.0347 0.0462 0.0578 0.0692 0.0808 0.0925 0.1044 0.1166 0.1468 0.1786 0.2117 4.10 0.0109 0.0219 0.0329 0.0439 0.0549 0.0659 0.0770 0.0882 0.0997 0.1115 0.1356 0.1652

-0.1962 4.20 0.0101 0.0205 0.0308 0.0411 0.0515 0.0619 0.0125 0.0832 10.0941 0.1054 0.1283 0.1529 0.1818-L::

4.30 0.-0094 0.0189 0.0285 0.0382 0.0479 0.0577 0.0676 0.0776 0.0879 0.0985 0.1202 0.1424 0.1684 14.40 10.0089 1 0.0180 0.0272 0.0365 0.0459 0.0552 0.0644 0.0737 f0.0829 0.0921 0.1117 0.1325 0.1560 I t

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 78 of 349 Date: 08/27/03 4.50 0.0086 0.0173 0.0262 0.0351 0.0441 l 0.0531 l 0.0621 0.0710 0.0799 l 0.0887 0.1063 0.1239 0.1445 4.60 0.0082 0.0166 0.0251 0.0338 0.0425 0.0511 0.0598 0.0684 0.0770 0.0855 0.1025 0.1199 0.1373 4.70 0.0083 0.0167 0.0252 0.0339 0.0428 0.0519 0.0611 0.0705 0.0801 0.0399 0.1095 0.1289 0.1480 4.80 0.0086 0.0174 0.0262 0.0353 0.0446 0.0540 0.0637 0.0736 0.0837 0.0940 0.1148 0.1356 0.1562 4.90 0.0086 0.0173 0.0262 0.0352 0.0445 0.0540 0.0637 0.0736 0.0839 0.0944 0.1156 0.1371 0.1536 5.00 0.0081 0.0165 0.0249 0.0335 0.0424 0.0515 0.0608 0.0703 0.0802 0.0904 0.1112 0.1324 0.1539 5.19.

0.0073 0.0149 0.0226 0.0305 0.0386 0.0469 0.0554 0.0641 0.0732 4Q0826 0.1020 0.1220 0.1426 5.20 0.0065 0.0131 0.0199 0.0268 0.0338 0.0408 0.0482 0.0559 0.0638

=6.0721 0.0894 0.1075 0.1264 5.40 0.0060 0.0121 0.0184 0.0249 0.0314 0.0378 0.0442 0.0507 0.0578 0.0651 0.0800 0.0955 0.1116 5.60 0.0056 0.0113 0.0171 0.0231 0.0291 0.0351 0.0411 0.0471 0.0530 0.0590 0.070X 0.0825 0.0949 5.80 0.0052 0.0105 0.0159 0.0215 0.0271 0.0327 0.0382 0.0438 0.0493 0.0549 0.0659 0.0768 0.0877 6.00 0.0048 0.0097 0.0148 0.0200 0.0252 0.0304 0.0356 0.0408 0.0460 0.0512 0.0614 0.0716 0.0817 6.20 0.0046 0.0092 0.0139 0.0187 0.0235 0.0284 1 0.0332 0.0381 0.0429 0.0477 0.0573 0.0675 0.0776 6.40 0.0043 0.0087 0.0131 0.0176 0.0221 0.0266 0.0311 0.0356 0.0402 0.0448 0.0544 0.0642 0.0740 6.60 0.0039 0.0080 0.0121 0.0163 0.0206 0.0248 0.0291 0.0333 0.0375 0.0418 0.0502 0.0591 0.0684 6.80 0.0037 0.0074 0.0113 0.0153 0.0193 0.0233 0.0272 0.0312 0.0352 0.0392 0.0470 0.0548 0.0626 7.00 0.0034 0.0070 0.0106 0.0143 0.0181 0.0218 0.0256 0.0293 0.0330 0.0368 0.0442 0.0515 0.0588 7.20 0.0032 0.0066 0.0100 0.0135 0.0170 0.0205 0.0240.

0.0276 0.0311 0.0346 0.0415 0.0484 0.0553 7.40.

0.0030 0.0062 0.0094 0.0127 O.0.01.9.. 0.0193 0.0226

. 0.0260 0.0293

.0.0326 0.0391 0.0456 0.0521 7.60 0.0029 0.0058 0.0089 0.0120 0.0151 0.0182 0.0214 0.0245 0.0276 0.0307 0.0369 0.0430 0.0491 7.80 0.0027 0.0055 O.O084 0.0113 0.0143 0.0172 0.0202 0.0231 0.0261 0.0290 0.0349 0.0407 0.0464 8.00 0.0026 0.0052 0.0079 0.0107 0.0135 0.0163 0.0191 0.0219 0.0247 0.0275 0.0330 0.0385 0.0439 8.50 0.0022 0.0045 0.0069 0.0094 0.0118 0.0143 0.0167 0.0192 0.0216 0.0240 0.0289 0.0337 0.0384 9.00 0.0020 0.0040 0.0061 0.0083 0.0104 0.0126 0.0147 0.0169 0.0191 0.0212 0.0255 0.0297 0.0339 9.50 0.0018 0.0036 0.0054 0.0073 0.0093

- 0.0112 0.0131 0.0150 0.0169 0.0189 0.0226 0.0264 0.0301 10.00 0.0016 0.0032 0.0048 0.0066 0.0083 0.0100 0.0117 0.0134 0.0151 0.0169 0.0203 0.0236 0.0269

Calc Number: GEO.HBIP.03.02 Rev Number. 0 Sheet Number: 79 of 349 Date: 08/27/03 __>

Table 6-1 lb. Soil Spectra for M-7.0, Set 2, Higher Vs Soil ]Profile (sec) l 0.-l L

0.2g l

0.3g l

0.4, l

0.5e l

0.6g 0.7p 0 8g 0.9g I Og l

1.4c 1.6 I

0.01 0.1700 1 0.3243 1 0.4379 1 0.5271 j 0.6047a 0.6703 0.7626 1 0.8592 0.9465 1.0234 1 1.1506 1 1.2689 -

1.3665 0.03

. 0.1767 1 0.3350 0.4522 1 0.5397 1 0.6139 1 0.6803 1 0.7732 0.8708 1 0.9589 1 1.0366 1.1640 1 1.2769 1 1.3752 1 1 0.04 ! 0.1787 ] 0.3443 1 0.4648 1 0.5545 1 0.6294 1 0.6945 ] 07830 1 0.8813 1 0.9699 1 1.0488 l 1.1766 1 1.2850 1 1.3834 0.05 i0.1918'1i0.3465 0.4718 -1:51766 1 0.6523-[ -0.72&6 t 0.8032 0.8961I -0.9879 1.0662-1:1936 1 1.2936 1 L3940 3 0.06 0.2221 0.3957 0.5140 0.6163 0.6701 0.7017 0.7983 0.9031 0.9950 1.0801 1.2130 1.3053 1.3867 0.07 0.2252 0.3668 0.5097 0.6189 0.7132 0.8122 0.8918 0.9591 1.0270 1.1094 1.2403 1.3674 1.4599 0.08 0.2728 0.4395 0.5755 0.6911 0.7513 0.8519 0.9381 1.0197 1.1024 1.1713 1.2863 1.3638 1.4262 0.09 0.3128 0.5002 06609 0.7S42 0.8 604 0.9669 1.0650 1.1620 1.2526 1.3196 1.4320 1.5013 1.5309 0.10 0.3540 0.5616 07101 0.8518 0.9846 1.0865 1.1693 1.2489 1.3119 1.3595 1.4557 1.5238 1.5461 0.11 0.4170 0.6683 0.8515 1.0360 1.IS21 1.2678 1.3463 14319 1.5126 1.6005 1.7555 1.8725 1.9255 0.12 0.4267 0.8327 1.0435 1.1746 1.2705 1.3978 1.4880 1.5545 1.6195 1.6654 1.8196 1.9528 2.0247 0.13 0.4194 0.7827 1.0328 1.1864 1.2724 1.3404 1.4411 1.5193 1.5831 1.6180 1.7013 1.7714 1.8432 0.14 0.5264 0.9771 1.2156 1.3443 1.4455 1.5768 1.7110 1.8158 1.8848 1.9258 1.9022 1.8527 1.8762 0.15 0.4659 0.8257 1.1769 1.4089 1.5690 1.6854 1.7760 1.8372 1.SS48 1.9198 1.9694 2.0419 2.0928 0.16 0.5450 0.8994 1.1488 1.4394 1.6557 1.8196 1.9327 1.9984 2.0295 2.0354 2.0465 2.1845 2.3038 0.17 0.6053'

'.0040 1.2505

  • 1.4228 1.5853 T-7651 1.9309 2.0608 2.1640 2.3112 Z.482t' 2.5053 2.4979 0.18 0.6092 1.1479 1.4365 1.6207 1.7369.

1.7980 2.0467 2.2791 2.4932 2.6807 2.9070 2.9734 2.9851 0.19 0.6294 1.1827 1.5258 1.7825 1.9826 2.1023 2.1716 2.2191 2.2688 2.3305 2.5533 2.6443 2.6842 0.20 0.6084 1.1461 1.5289 1.8490 2.0967 2.2567 2.3444 2.3977 2.4325 2.4487 2.5138 2.6222 2.6812 0.21 0.6017 1.1560 1.5896 1.9526 2.2432 2.4165 2.5163 2.5766 2.6192 2.6276 2.6718 2.8273 2.9233 0.22 0.6274 1.1999 1.6100 1.9188 2.1825 2.4025 2.5626 2.6593 2.7496 2.8052 2.8402 2.9226 2.8814 0.23 0.5954 1.1496 1.5590 1.8509 2.1767 2.4926 2.7202 2.8883 3.0211 3.1153 3.2070 3.2045 3.1909 0.24 0.5304 1.0652 1.4908 1.9026 2.3218 2.6872 2.9612 3.1764 3.3456 3.4635 3.5663 3.6099 3.6170 0.25 0.4699 0.9173 1.3886 1.8595 2.3028 2.678 2.9773 3.2062 3.3852 3.5108 3.6275 3.7669 3.7501 0.26 0.4366 0.8675 1.3301 1.7881 2.2131 2.5809 2.8717 3.0928 3.2785 3.5336 3.9377 4.1809 4.3328 0.27 0.3521 0.6871 1.0930 1.5121 1.9184 2.2988 2.6313 2.9346 3.2248 3.48S6 3.9619 4.2816 4.4589 0.28 0.3747 0.6795 0.9915 1.3830 1.7730 2.1526 2.4964 2.8228 3.1366 3.4406-3.9819 4.3348 4.5444 0.29 1 0.3918 0.6954 1 1.0011 1.2610 1.6109 1.9877 I 2.3582 2.7210 3.0760 3.4066 1 3.9387 4.3048 4.5348 0.30 0.3768 0.6718 0.9849 1.2709 1.5587 1.8782 2.2125 2.5469 l2.8766 3.1874 3.7109 4.0340 4.1609 0.31 0.3877 0.6825 0.9306 1.1717 1.4142 1.7057 2.0085 2.3119 2.6112 2.8939 3.4023 3.8742 4.2057 0.32 0.3966 0.7166 1.0161 1.2765 1.5154 1.7485 1.9843 2.2379 2.5031 2.8364 3.4721 4.0631 4.5531 0.33 0.3975 0.6937 0.9869 1.2441 1.4800 1.7119 1.9514 2.2046 2.4775 2.7503 3.4576 4.1715 4.7089 0.34 0.4031 0.6777 0.9108 1.1422 1.3S38.

1.5597 1.7676 1.9905 2.2287 2.468X 2.9906 3.6469 4.1607 0.35 0.4090 0.7074 0.9761 1.1840 1.3533 1.5102 1.7239 1.9407 2.1733 2.4203 2.9427 3.4921 3.9257 0.36 0.4233 0.7709 1.0728 1.3156 1.5204 1.7048 1.8706 2.0363 2.2024 2.3653 2.8107 3.3269 3.7390 0.37 0.3889 0.7213 1.0258 1.2761 1.4912 1.6898 1.8739 2.0543 2.2367 2.4120 2.7420 3.0889 3.4781 0.38 0.3854 0.7181 1.0023 1.2374 1.4364 1.6168 1.7897 1.9653 2.1455 2.3294 2.6947 3.0571 3.3194 0.39 0.3831 0.7258 1.0214 1.2569 1.4670 1.6592 1.8388 2.0174 2.1970 2.3676 2.6741 3.0085 3.2514 0.40 0.3908 0.7761 1.1028 1.3350 1.4862 1.6746 1.8570 2.0422 2.2276 2.4074 2.7246 2.9944 3.1713 0.41 0.3976 0.7983 1.1486 1.4041 1.5740 1.6854 1.7996 1.9812 2.1676 2.3466 2.6652 2.9318 3.1065 0.42 0.3901 0.7929 1.1559 1.4285 1.6131 1.7343 1.9066 2.0860 2.2531 2.3964 2.5932 2.8323 3.0342 0.43 03670 0.7559 1.1154 1.3925 1.5827 1.7818 1.9931 2.1900 2.3753 2.5401 2.7792 2.8962 2.9644 0.44 0.3304 0.6888 1.0282 1.2940 1.5938 1.8415 2.0227 2.2103 2.4073 2.5867 2.8572 3.0063 3.0374 0.45 0.3108 0.6426 1.0081 1.3818 1.7025 1.9577 2.1456 2.3183 2.4791 2.6116 2.8627 3.0354 3.0841 0.46 03025 0.6293 0.9853 1.3435 1.6513 1.9317 2.1516 2.3364 2.4989 2.6352 2.8395 3.0286 3.1243 0.47 0.2738 0.5695 0.8907 1.2169 1.5283 1.7896 1.9925 2.1606 2.3113 2.4840 2.8030 3.0203 3.1662 0.48 0.2711 0.5572 0.8401 1.1130 1.360S 1.5958 1.8164 2.0278 2.2340 2.4313 2.7717 3.0512 3.2054 0.49 0.2686 0.5524 0.S339 1.1062 1.3566 1.5942 1.8185 2.0344 2.2426 2.4406 2.7930 3.0789 3.2395 0.50 0.2653 0.5461 0.8262 1.0982 1.3492 1.5881 1.8148 2.0333 2.2450 2.4445 2.8012 3.0915 3.2590 0.51 0.2604 0.5367 0.8135 1.0838 1.3330 1.5721 1.7992 2.0173 2.22S6 2.4299 2.7881 3.0809 3.2531 0.52 0.2542 0.5245 0.7959 1.0621 1.3079 1.5445 1.7692 1.9857 2.1948 2.3950 2.7521 3.0461 3.2242 0.53 0.2472 0.5104 0.7757 1.0360 1.2775 1.5097 1.7308 1.9445 2.1515 2.3490 2.7039 2.9998 3.1844 0.54 0.2400 0.4958 0.7545 1.0085 1.2449 1.4723 1.6895 1.8998 2.1042 2.2992 2.6528 2.9502 3.1402 0.55 0.2331 0.4816 0.7336 0.9816 1.2127 1.4355 1.6489 1.8560 2.0577 2.2510 2.6032 2.9028 3.0989 0.56 0.2269 0.4687 0.7145 0.9573 1.1836 1.4028 1.6131 1.8177 2.0174 2.2101 2.5625 2.8661 3.0691 0.57 0.2215 0.4574 0.6981 0.9366 1.1593 1.3759 1.5845 1.7878 1.9868 2.1802 2.5356 2.8445 3.1470 0.58 0.2162 0.4466 0.6826 0.9174 1.1375 1.3523 1.5600 1.7630 1.9623 2.1568 2.5627 3.0075 3.3303 0.60 0.2024 0.4183 0.6424 0.8670 1.0801 1.2890 1.4924 1.7003 1.9322 2.1699 2.6537 3.1213 3.4610 0.62 0.1982 0.3880' 0.5787 0.7857 0.9827 1.1778 1.3689 1.5569 1.7429 1.9595 2.4188 2.8683 3.2077 0.64 0.1990 0.3967 0.5938 0.7863 0.9615 1.1305 1.3027 1.4832 1.6734 1.8751 2.3103 2.7754 3.2149 0.66 0.1894 0.3764 0.5661 0.7547 0.9275 1.0933 1.2587 1.4293 1.6072 1.7941 2.1927 2.6179 j 3.0220

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 80 of 349 Date: 08/27/03 0.68 0.1764 0.3487 0.5250 0.7023 0.8656 1.0218 1.1756 1.3325 1.4951 1.6647 2.0237 12.4047 2.7673 0.70 0.1714 0.3358 0.5038 0.6743 0.8321 0.93011.1311.

1.2804 1.43401.5938 1.9303 2.2862 2.6275 0.72 0.1801 0.3442 0.5005 0.6693 0.8270 0.9782 1.1262 1.2745 1.4264 1 15X3X

.9142I 2.2646 2.6064 0.74 0.1776 0.3442 0.5023 0.6612 0.79

.64 1.1176 1.2653 I 1.4158 1 15713 -1 18980 3 224465 4 254 0.76 0.1880 7

0.3555 4

0.5069 3 0.656 12 0.7936 1 0.9332 6

1.0776 I 1.2210 6

1.3663 15160 l 1.8308 1 2.1714 O.ISS0

~

l

.5Sl056

.6S l

.96l093+

.76l121

.63lIS6

.3Xl211 I 2.5174 1 0.78 0.1811 0.3448 0.4970 0.6473 0.7815 10.9073 1.0306 1.1553 11.2829 1.4138 1.6873 2.0053 2.33.88

.fl.D80..

. 0.1846

-0.352D.-

0.5039..

0.6425.

0.7604 0.8632 0.9.687~..1 1.0846 11.2023 11.3229.

1.5732...18-r.7..

.2.1079 0.82 0.1973 0.3766 0.5408 0.6922 0.8223 0.93-78 1.0439 1.1458 1.2440 1.3383 1.5158 1.6900 1.9108 0.84 0.1953 0.3734 0.5387 0.6939-0.8293 0.9513 1.0753 1.1982 1.3153 1.4241 1.6162 1.7815 1.9949 0.86 0.1854 0.3656 0.5391 0.7094 0.8680 1.0158 1.1552 1.2876 1.4138 1.5326 1.7464 1.9314 2.0926 0.88 0.2001 0.3919 0.5764 0.7577 0.9283 1.0893 1.2429 1.3903 1.5322 1.6672 1.9133 2.1295 2.3176 0.90 0.2080 0.4057 0.5946 0.7797 0.9548 1.1215 1.2822 1.4375 1.5880 1.7326 1.9986 2.2356 2.4412 0.92 0.2082 0.4099 0.6004 0.7822 0.9484 1.1150 1.2767 1.4342 1.5878 1.7358 2.0 116 2.2595 2.4738 0.94 0.2100 0.4146 0.6097 0.7971 0.9672 1.1200 1.2603 1.3930 1.5448 1.6922 1.9679 2.2182 2.4341 0.96 0.2080 0.4110 0.6060 0.7941 0.9665 1.1228 1.2673 1.4035 1.5332 1.6554 1.9034 2.1508 2.3639 0.98 0.2050 0.4052 0.5987 0.7862 0.9593 1.1175 1.2642 1.4026 1.5343 1.6582 1.8802 2.0918 2.3017 1.00 0.2023 0.3999 0.5917 0.7783 0.9513 1.1104 1.2583 1.3982 1.5314 1.6568 1.8805 2.0721 2.2544 1.05 0.1880 0.3722 0.5516 0.7275-0.8925 1.0467 1.1921 1.3299 1.4617 1.5857 1.8073 1.9954 2.1380

.1.10 -.

0.1721 03433-0.5116 0.6783 0.8369.

0.9872 1.1302-f Y-11.666 31.3973 :1.5210 1.7433.

.1-.932-7 27.09'70 1.15 0.1654 0.3431 0.5294 0.7190 0.9047 1.0794 1.2422 1.3935 1.5350 1.6645 1.8826 2.0444 2.2277 1.20 0.1691 0.3511 0.5399 0.7315 0.9179 1.0925 1.2544 1.4064 1.5632 1.7105 2.6148 2.2830 2.5024 1.25 0.1417 0.2968 0.4617 0.6332 0.8059 0.9846 1.1619 1.3343 L.5028 1.6666 1.9762 2.2561 2.4940 1.30 0.1239 0.2621 0.4122 0.5708 0.7356 0.9018 1.0668 1.2284 1.3869 1.5418 1.8379 2.1 106 2.3480 1.35 0.1135 0.2393 0.3751 0.5187 0.6683 0.8199 0.9713 1.1204 1.2675 1.4t24 1.6916 1.9530 2.1859 1.40 0.1040 0.2194 0.3437 0.4752 0.6128 10.7531 0.8940 1.0336 1.1721 1.3093 1.5766 1.8307 2.0623 1.45 0.0977 0.2062 0.3241 0.4492 0.5812 0.7169 0.8540 10.9906 1.1267 1.2623 1.5295 1.7864 2.0247 1.50 0.0910 0.1921 0.3032 0.4226 0.5502 0.6831 0.8187 0.9542 1.0918 1.2308 1.5112 1.7899 2.0589 1.55 0.0889 0.1846 0.2903 0.4073 0.5335 0.6664 0.8030 0.9404 1.0790 1.2191 1.5015.

1.7817 2.0488 1.60 0.0811 0.1676 0.2584 0.3533 0.4604 0.5770 0.6972 0.8185 0.9406 1.0642 1.3127 1.5583 1.790-7 1.65 0.0751 0.1552 0.2399 0.3284 0.4212 0.5177 0.6173 0.7184 0.8211 0.9258 1.1399 1.3583 1.5757 1.70 0.0642 0.1320 0.2033 0.2777 0.3557 0.4374 0.5225 0.6103 0.7007 0.7946 0.9938 1.2096 1.4456 1.75 0.0577 0.1192 0.1843 0.2525 0.3238 0.3981 0.4750 0.5540 0.6352 0.7192 0.8963 1.0868 1.2933 1.80 0.0498 0.1022 0.1586 0.2187 0.2828 0.3508 0.4219 0.4949 0.5700 0.6478 0.8121 0.9934 1.1977 1.85 0.0486 0.1004 0.1557 0.2143 0.2770 0.3433 0.4127 0.4840 0.5573 0.6332 0.7938 0.9668 1.1554 1.90 0.0474 0.0976 0.1510 0.2076 0.2679 0.3319 0.3987 0.4675 0.5381 0.6114 0.7663 0.9333 1.15 1.95 0.0455 0.0936 0.1446 0.1986 0.2560 0.3170 0.3806 0.4461 0.5135 I0.5833 0.7310 10.8904 1,65 2.00 0.0429 0.0883 0.1364 0.1872 0.2414 0.2988 0.3588 0.4205 0.4840 0.5498 0.6891 0.8397 1..j04.

2.05 0.0407 0.0837 0.1288 0.1756 0.2246 0.2778 0.3337 0.3913 0.4505 0.5 120 0.6421 0.7830 0.9380 2.10 0.0388 0.0798 0.1228 0.1675 0.2144 0.2632 0.3137 0.3652 0.4179 0.4720 0.5920 0.7229 0.8675 2.15 0.0368 0.0757 0.1167 0.1594 I0.2041 0.2507 0.2989 0.3481 0.3984 0.4501 0.5582 0.6732 0.7976 2.20 0.0348 0.0717 0.1106 0.1512 0.1938 0.2382 0.2842 0.3311 0.3790 0.4283 0.5314 0.6412 0.7601 2.25 0.0328 0.0677 0.1046 0.1431 0.1836 0.2259 0.2696 0.3142 0.3599 0.4068 0.5051 0.6099 0.7235 2.30 0.0309 0.0639 0.0987 0.1352 0.1736 0.2138 0.2554 0.2979 0.3413 0.3860 0.4796 0.5796 0.6882 2.35 0.0292 0.0603 0.0932 0.1278 0.1642 0.2024 0.2419 0.2822 0.3236 0.3661 0.4553 0.5506 0.6544 2.40 0.0278 0.0572 0.0883 0.1209 0.1555 0.1917 0.2292 0.2676 0.3068 0.3473 0.4322 0.5231 0.6223 2.50 0.0254 0.0522 0.0804 0.1096 0.1402 0.1725 0.2063 0.2409 0.2763 0.3128 0.3897 0.4722 0.5625 2.60 0.0239 0.0488 0.0745 0.1009 0.1282 10.1563 0.1849 0.2160 0.2478 0.2807 0.3499 0.4245 0.5063 2.70 0.0205 0.0419 10.0642 0.0874 0.1119 0.1377 0.1647

0. 1924 0.2208 0.2501 0.3121 0.3790 0.4526 2.80 0.0215 0.0436 0.0664 0.0899 0.1137 0.1379 0.1623 0.1869 0.2119 0.2374 0.2904 0.3463 0.4054 2.90 0.0220 0.0442 0.0668 0.0906 0.1149 0.1397 0.1647 0.1900 0.2156 0.2417 0.2959 0.3533 0.4147 3.00 0.0237 0.0476 0.0718 0.0962 0.1206 0.1451 0.1695 0.1939 0.2181 0.242-2 0.2896 0.3386 0.3986 3.10 0.0232 0.0468 0.0708 0.0951 0.1197 0.1444 0.1694 0.1943 0.2194 0.2443 0.2941 0.3432 0.3911 3.20 0.0211 0.0428 0.0649 0.0874 0.1103 0.1335 0.1570 0.1806 0.2044 0.2283 0.2761 0.3239 0.3711 3.30 0.0181 0.0367 0.0560 0.0756 0.0957 0.1161 0.1369 0.1579 0.1791 0.2004 0.2436 0.2871 0.3303 3.40 0.0152 0.0306 0.0464 0.0626 0.0790 0.0959 0.1134 0.1311 0.1490 0.1671 0.2043 0.2430 0.2833 3.50 0.0143 0.0287 0.0429 0.0570 0.0721 0.0875 0.1033 0.1192 0.1354 0.1517 0.1852 10.2194 0.2542 3.60 0.0142 0.0289 0.'0440 0.0593 0.0746 0.0899 0.1051 0.1203 0.1357 0.1512 0.1827 0.2148 0.2476 3.70 0.0142 0.0287 0.0435 0.0583 0.0733 0.0882 0.10-29 0.11-78 0.1332 0.1488 0.1806 0.2132 0.2468 3.80 0.0139 0.0282 0.0428 0.0576 0.0725 0.0876
0. 1025 0.1173 0.1320 0.1465 0.1751 0.2035 0.2325 3.90 0.0129 0.0264 0.0403 0.0544 0.0687 0.0831 0.0976 0.1119 0.1262 0.1404 0.1684 0.1963 0.2245 4.00 0.0120 0.0240 0.0367 0.0497 0.0630 0.0765 0.0900 0.1035 0.1170 0.1304 0.1572 0.1838 0.2106 4.10 0.0112 0.0225

-0.0339 0.0453 0.0568 0.0694 10.0821 0.0948 I0.1-074 0.1'200 0.1450 0.1700 0.1950 4.20 0.0105 0.0211 0.0317 0.0424 0.0530 0.0635 0.0741

0. 0856 0.0971 0.07 0.1317 0.1547 0.1779 4.30 0.0098 0.0197 0.0298 0.0398 0.0498 0.0597 0.0695 0.0793 0.0891 099 0.1185 0.1393

_0.1605 4.40 0.0092 0.0186 0.0280 I0.0375 0.0469 0.0562 0.0655 1 0.0748 0.0840 0.0933 I0.1118 0.1304 0.1494

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 81 of 349 Date: 08/27/03 I 4.50 0.0087 0.0176 0.0265 0.0355 0.0445 0.0533 0.0621 0.0709 0.0797 l 0.0885 0.1061 0.1237 0.ii44 4.60 0.0083 - 0.0168 0.0253 3 0.0339 1 0.0424 0.0509 0.0593 0.0676 0.0760 0.0844 0.1012 0.1180 0.1349 -

4.70 0.0080 0.0161 0.0242 1 0.0325 3 0.0407 0.0488 0.0568 0.0649 0.0730 10.0810 1 0.0971 0.1133 0.1295 4.80 0.0077 1 0.0155 0.0233 0.0313 J 0.0392 0.0470

- 0.0548 0.0626 0.0703 1 0.0781 1 0.0937 0.1093 0.1249 4.90 0.0074 1 0.0149 0.0226 1 0.0302 1 0.0379 0.0455 0.0530 i 0.0605 1 0.0681 0.0756 I 0.0907 0.1058 1 0.12101 3.00 0.0072 0.0145 0.0218 0.0293 0.0367 0.0441 0.0514 0.0587 0.0660 0.0734 0.0880 0.1027 0.1175 5.10 0.0069 0.0140 0.0212 0.0284 0.03-56

.0.0428-0.0499 0.05;Q 0.0642 0.0713

. U..855 0.0998 0.1142 5.20 0.0067 0.0136 0.0205 0.0276 0.0346 0.0415 0.0485 0.0554 0.0623 0.0693 0.0831 0.0971 0.1111 5.40 0.0063 0.0127 0.0193 0.0259 0.0325 0.0390 0.0456 0.0521 0.0587 0.0652 0.0784 0.0916 0.1049 5.60 0.0058 0.0118 0.0179 0.0241 0.0302 0.0364 0.0425 0.0487 0.0548 0.0610 0.0733 0.0857 0.0982 5.80 0.0054 0.0109 0:0165 0.0222 0.0279 0.0336 0.0393 0.0450 0.0507 0.0564 0.0678 0.0794 0.0910 6.00 0.0049 0.0099 0.0150 0.0202 0.0254 0.0306 0.0359 0.0411 0.0463 0.0516 0.0621 0.0727 0.0834 6.20 0.0048 0.0096 0.0143 0.0191 0.0237 0.0282 0.0326 0.0371 0.0418 0.0466 0.0561 0.0658 0.0755 6.40 0.0047 0.0093 0.0140 0.0187 0.0232 0.0277 0.0320 0.0363 0.0405 0.0446 0.0524 0.0598 0.0677 6.60 0.0045 0.0090 0.0135 0.0179 0.0224 0.0267 0.0310 0.0352 0.0393 0.0433 0.0511 0.0595 0.0678 6.80 0.0042 0.0085 0.0128 0.0170 0.0213 0.0254 0.0295 0.0336 0.0375 0.0414 0.0492 0.0584 0.0667 7.00 0.0039 0.0079 0.0119 0.0160 0.0199 0.0239 0.0278 0.0316 0.0354 0.0396 0.0481 0.0564 0.0645 7.20 0.0036 0.0073 0.0111 0.0148 0.0185 0.0222 0.0259 0.0297 0.0337 0.0377 0.0458 0.0538 0.0616 7.40 0.0033 0.0067 0.01902

' 0:0136 0.0170 0.0205 0.0241 0:0279 0.0317 0.0355 0.0431 0.0507. 0.05Mk.

7.60 0.0030 0.0061 0.0092 0.0124 0.0155 0.0189 0.0224 0.0259 0.0295 0.0330 0.0402 0.0474 0.0544 7.80 0.0028 0.0056 0.0085 0.0114 0.0144 0.01'75 0.0207 0.0239 0.0272 0.0305 0.0372 0.0439 0.0505 8.00 0.0027 0.0054 0.0081 0.0108 0.0135 0.0164 0.0193 0.0222 0.0251 0.0280 0.0342 0.0404 0.0465 8.50 0.0024 0.0048 0.0073 0.0099 0.0124 0.0150 0.0176 0.0202 0.0228 0.0254 0.0307 0.0361 0.0415 9.00 0.0024 0.0049 0.0073 0.0097 0.0122 0.0146 0.0169 0.0193 0.0216 0.02 85 0.0330 0.0382 9.50 F 0.0023 0.0045 0.0068 0.0091 0.0114 0.0136 0.0159 0.011 0.0203 0.0225 0.0269 0.0312 0.0354 10.00 0.0020 0.0039 0.0059 0.0079 0.0099 0.0119 0.0139 0.0158 0.0178 0.0197 0.0236 0.0274 0.0311

'I.

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 82 of 349 Date: 08127/03 Table 6-I Ic. Soil Specara fo r M 7.0, Se 31, Hiogher Vs Soil Profile Per I1 (sec)

O. 1R 0.2g 0.3-g 0.4 sZ 0.5, Me6 0.7g. j g

0.9pg l.O9 t.2%z 1.4' 1.6g 0.01 0.1962 0.3714 0.5187 0.6353 10.7247 0.7977 0.8591 10.9198 10.9829 1.0421 11.1434 1.2176 1.2748 0.03 0.2017 0.3811 0.5307 0.6478 0.7380 0.8107 0.8717 10.9324 10.9959 -

1.034-7 11.1555 11.2290 11.2864 0.04 0.2140 0.3997 0.5480 0.6641 0.7544 0.8266 0.8868 10.94468 1.0096 1.0679 11.1678 11.2405 11.2971 0.05 0.2237 0:'4127 0.5627-

'O.67Y8 0.7694 0.8419-O.'9028 0.9635 1.0267 1.-0851 11:1838 I--1.2563 11.3119 0.06 0.2428 0.4452 0.5930 0.7188 0.8124 0.8840 0.9424 1.0005 1.0614 11.1177 11.2119 11.2819 1.3345 0.07 0.2954 0.5323 0.6967 0.8044 0.8825 0.92'70 0.9433 1.0067 1.0717 11.1305 11.23 13 11.3016 1.3525 0.08 0.3053 0.4905 0.6775 0.8176 0.9254 0.9997 1.0414 1.0680 1.1268 1.1856 11.2809 11.3457 1.3940 0.09 0.3342 0.4963 10.6841 0.8457 0.9652 1.0545 1.1011 1.1131 1.1380 1.2004 11.3060 1.3739 1.4216 0.10 0.4047 0.6130 0.7375 0.8800 1.0125 1.1137 1.1760 11.2010 1.2156 1.2589 11.3519 1.4201 1.4644 0.11 0.4422 0.7141 0.8709 0.9595 1.0478 11.1378 1.2048 11.2705 1.3527 1.4098 1:.4;.557 1.4956 1.5303 0.12 0.3841 0.7007 0.9757 1.1938 1.3594 11.4835 1.5555 1.5770 1.5610 1.5195 1.4180 1.4830 1.5236 0.13 0.4629 0.8078 1.1303 1.3849 1.5899 11.7367 1.8289 1.8733 1.8724 1.8370 1.7096 1.5415 1.5825 0.14 0.4423 0.8070 1.1458 1.4151 1.6394 11.8102 1.9241 1.9915 2.0124 1.9925 1.8888 1.7093 1.6173 0.15 0.4372 0.7777 1.1088 1.2957 1.5081 1.6963 1.8330 1.9187 1.9568 1.9559 1.8718 11.7101 1.6107

.~0.16 0.4892 0.7594 11.0909 1.3276 1.4992 1.6478 1.7478 1.8415 1.8902 1.8956 1.8238 1.,7022 1.6402 0.17 05944 09445

.0747

.3404

.5371 1.7194 1.8896 1.9960

-2.05A4I 2.1327 12.2366 2.12627 2.2174-0.18 0.6252 1.0830 1.3179 1.3748 1.4381 1.6207 1.8420 1.2.0792 2.2684 2.3998 12.5301 12.5650 2.4976 0.19 0.5470 1.0248 1.3451 1.5-716 1.6743 1.7744 1.9207 2.0135 2.0878 2.2354 2.4046 12.4388 12.3707 0.20 0.5873 1.1750 1.6547 1.9090 2.0232 2.1119 2.2795 2.3929 2.4584 2.4865 2.4608 12.3486 12.204-2 0.21 0.104 1.0188 1.4181 1.8185 2.1678 2.4423 2.6439 2.7822 2.873 2.9277 2.9492 2.85071 2.6912 0.22 0.5287 0.9771 1.4102 1.8377 2.1918 2.4843 2.7113 2.8852 3.0156 3.1076 3.1909 3.1361 12.9664 0.23 0.5251 L.0164 1.3871 1.7654 2.1228 2.4284 2.6786 2.8937 3.0619 3.1833 3.3051 3.2721 13.1225 0.24 0.4869 1.0574 1.5242 1.8009 2.1760 2.5112 12.8015 3.0430 3.2341 13.3792 3.5323 3.5235 13.3812 0.25 0.4339 0.9533 1.3916 1.7557 2.1399 2.492-7 12.8047 3.0677 3.2848 3.4499 3.6436 3.6726 13.5667 0.26 0.3997 0.7911 1.2183 1.6219 2.0056 2.3633 2.6901 2.9705 3.2063 3.3933 3.6366 3.7185 13.6593 0.27 0.4152 0.7854 1.1231 11.5174 1.9056 2.2730 2.6153 2.9141 3.1743 3.3856 3.6806 3.8121 13.7933 0.28 0.4315 0.8168 1.1755 1.4816 1.8904 2.2812 2.6327 2.9285 13.1812 3.3801 3.6840 3.8888 13.9825 0.29 0.4370 0.277 1.1921 1.4866 1.7270 2.0957 2.4300 2.7061 12.9361 3.1112 3.4703 3.7041 3.7822 0.30 0.4366 0.8276 1.1934 1.4873 1.7285 1.9396 2.1246 12.4215 12.7304 2.9895 13.36-29 13.5620 13.6771 0.31 0.4338 0.8221 1.1868 1.4786 1.7191 1.9265 2.1075 2.2835 12.5585 2.7987 13.0996 3.3729 3.5477 0.32 0.4303 0.8146 1.1754 1.4652 1.7008 1.9031 2.0788 2.2500 2.4266 2.5981 13.0920 3.5946 3.9479 0.33 0.4290 0.8115 1.1684 1.4557 1.6867 1.8843 2.0550 2.2223 2.4045 2.6644 13.2017 3.7309 4.1151 0.34 0.4290 0.8112 1.1659 1.4524 1.6808 11.8782 2.0477 2.2130 2.3862 2.5522 12.9502 3.4488 3.8249 0.35 0.4257 0.8059 71.1586 1.4407 1.6690 11.8629 2.0292 2.1928 2.3663 2.5289 2.8209 3.1887 3.5659 0.36 0.4248 0.8036 1.1538 1.4328 1.6568 11.8456 2.0071 2.1674 2.3402 2.5039 2.7934 3.0489 3.4536 0.37 0.4272 0.8058 1.1525 1.4303 1.6500 1.8371 1.9960 12.1539 2.3254 2.4927 2.7884 3.0163 3.1907 0.38 0.4512 0.7935 1.1341 1.4063 1.6224 1.8040 1.9650 12.1340 2.3029 2.4568 2.7575 2.9918 3.1794 0.39 0.4367 0.8187 1.1028 1.3530 1.5725 1.7951 1.9832 12.1567 2.3318 2.4930 2.7589 2.9230 3.0881 0.40 0.4125 0.7819 1.0632 1.3028 1.5629 1.7873 1.9787 2.1538 2.3293 2.4920 12.7619 2.9283 3.0080 0.41 0.3590 0.6838 0.9852 1.2835 1.5438 1.7708 1.9611 2-.1352 2.3112 2.4734 12.7420 2.9047 2.9797 0.42 0.3326 0.6421 0.9632 1.2621 1.5247 1.7500 1.9384 2.1104 2.2829 2.4437 2.7072 2.8653 12.9344 0.43 0.3150 0.6269 0.9501 1.2509 1.5143 1.7396 1.9249 2.0923 2.2624 2.4195 2.6770 2.8270 12.8884 0.44 0.3061 0.6219 0.9405 1.2425 1.5050 1.7247 1.9047 2.0662 2.2315 2.3842 2.6360 2.8041 2.9463 0.45 0.3000 0.6228 0.9429 1.2325 1.4707 11.6673 1.8355 2.0296 2.2165 2.3927 2.7051 12.9366 3.0869 0.46 0.2875 0.60'72 0.9283 1.2244 1.4713 11.6648 1.8752 12.0709 2.2605 2.4393 2.7593 2.9993 3.1588 0.47 0.2837 0.5712 0.8798 1.1697 1.4154 11.6531 1.8564 12.0587 2.2352 2.4139 2.7362 2.9820 3.1501 0.48 0.2785 0.5594 0.8462 1.1237 1.4238 11.6901 1.9561 12.1717 2.3499 2.4881 2.6759 2.9245 3.0980 0.49 0.2726 0.5462 0.8239 1.0853 1.3714 1.6795 1.9474 2.1660 2.3549 2.5146 12.7190 2.8772 13.0541 0.50 0.2684 0.5368 0.8087 1.0644 1.3354 1.6254 1.8840 2.1071 2.3032 2.4646 12.6746 2.855-2 13.0322 0.51 0.2654 0.5300 0.7980 1.0504 1.2859 1.5322 1.7781 1.9914 2.1790 2.3362 12.5887 12.83-72 13.0133 0.52 0.2615 0.5218 0.7851 1.0337 1.2660 1.4840 1.6862 1.8782 2.0640 2.2396 12.5545 12.7995 12.9754 0.53 0.2562 0.5108 0.7678 1.0107 1.2381 1.45 17 1.6499 1.8378 2.0195 2.1911 12.4990 12.7413 12.9188 0.54 0.2506 0.4989 0.7491 0.9853 1.2065 1.4147 11.6082 1.7915 1.9687 2.1362 2.4390 2.6812 12.8622 0.55 0.2458 0.4886 0.7329 0.9631 1.1791 11.3823 1.5722 1.7523 1.9263 2.0913 2.4646 2.7453 12.8714 0.56 0.2422 0.4806 10.7205 0.9460 1.1587 11.3586 1.5461 1.7249 1.8977 2.0929 2.4991 2.7757 12.9029 0.57 0.2391 0.4742 10.7103 0.9326 1.1426 1.3410 1.5274 1.7056 1.8788 2.0759 2.4771 2.7554 2.8816 0.58 0.2359.

0.4678 0.7003 0.9197 1.1269 1.3239 1.5095 1.6872 1.8598 2.0305 2.4236 2.7016 2.8304 0.60 0.2291 0.4536 0.6787 0.8909 1.0924 1.2841 1.4662 1.6411 1.8104 1.9731

-2.2700 2.5151 2.7020 0.62 0.2227 0.4405 0.6585 0.8644 1.0600 1.2475 1.4259 1.59'76 1.7643 1.9372L

.2175 2.46 04 2.6493 0.64 0.2168 0.4285 0.6405 0.8406 1.0318 1.2152 1.3903 1.5597 1.7244~ 1.825 12.1729 2.4161 2.6057 0.66 0.2101 0.4154 0.6204 0.8145 0.9998 1.1786 130 1.161 1.6773 1.83191_.1181 2.3371 2.5459

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 83 of 349 Date: 08/27/03

-I 0.68 0.2037 1 0.4026 1 0.6012 1 0.7886 1 0.9684 1.1419 I 1.3086 1 1.4702 1.6274 ( 1.7786 1 2.0578 1 2.2933 2.4794 0.70 0.1993 0.3932 0.5868 0.7694 0.9448 1.1142 1.2777 1.4364 1.5904 1.7393 2.0145 2.248 I 2.4357 0.72 0.1958 0.3861 0.5757 0.7549 0.9268 1.0939 1.2554 1.4124 1.5650 1.7121 1.9R63 2.2201 2.4115 0.74 0.1917 0.3778 0.5634 0.7385 0.9072 1.0711 1.2300 1.3852 1.5361 1.6823 1.9549 2.1903 2.3S50 0.76 0.1865 03674 0.5477 0.71S1 0.8324 1.0427 1.1986 1.3509 1.4995 1.6433 1.9130 2.1479 2.3442 0.78 0.1914 0.3606 0.5313 0.6966 0.8565 1.0127 1.1653 1.3146 1.4601 1.6011 1.8672 2.0999 2.2964 0.8Q -

0.2000 0.3795 -. 0.5417 0.6776 0.8335 0.9861 1 1.354.

1.2819 1.4245. -t5634

. 1.8255 2.0562..

.2.2533 0.82 0.2074 0.3960 0.5687 0.7135 0.8373 0.9623 1.1087 1.2526 1.3928 1.5295 1.7886 2.01 SS 2.2180 0.84 0.2133 0.4093 0.5912 0.7463 0.S810 1.0016 1.109 1.2215 1.3594 1.4939 1.7503 1.9810 2.1836 0.86 0.2164 0.4174 0.6063 0.7700 0.9140 1.0443 1.1612 1.2684 1.3674 1.4604 1.7041 1.9353 2.1428 0.88 0.2160 0.4186 0.6114 0.7809 0.9325 1.0709 1.1961 1.3113 1.4176 1.5164 1.6967 1.8801 2.0930 0.90 0.2119 0.4127 0.6061 0.7786 0.9354 1.0800 1.2123 1.3344 1.4473 1.5518 1.7396 1.9084 2.0796 0.92 0.2050 0.4011 0.5924 0.7656 0.9250 1.0737 1.2109 1.3385 1.4567 1.5660 1.7610 1.9316 2.0977 0.94 0.1968 0.3869 0.5739 0.7455 0.9055 1.0558 1.1958 1.3263 1.4481 1.5608 1.7618 1.9347 2.0977 0.96 0.1891 0.3725 0.5539 0.7223 0.8806 1.0305 1.1712 1.3031 1.4265 1.5412 1.7459 1.9212 2.0S25 0.98 0.1824 0.3590 0.5343 0.6984 0.8539 1.0021 1.1419 1.2737 1.3974 1.5128 1.719S 1.8965 2.0571 1.00 0.1764 0.3470 0.5163 0.6759 0.8279 0.9736 1.1119 1.2429 1.3660 1.4815 1.6895 1.8676 2.0278 1.05 0.1838 0.3635 0.5323 0.6739 0.7917 0.9138 1.0480 1.1761 1.2973 1.4118 1.6206 1.8004 1.9604 1.l0 0.1765 0.3566 0.5308 0.6830

0.811 7'

- 0.9320 1.0738

-I.2058 1.3271 1.4376 1.6286 1.7759 1.9037 1.15 0.1581 0.3180 0.4787 0.6437 0.8044 0.9600 1.1081 1.2471 1.3758 1.4940 1.6999 1.8605 1.9805 1.20 0.1477 0.3067 0.4697 0.6317 0.7890 0.9415 1.0874 1.2253 1.3538 1.4732 1.6832 1.8503 1.9786 1.25 0.1395 0.2895 0.4439 0.5973 0.7465 0.8916 1.0315 1.1653 1.2914 1.4096 1.6215 1.7954 1.9344 1.30 0.1278 0.2651 0.4073 0.5497 0.6899 0.8285 0.9648 1.0971 1.2224 1.3410 1.5571 1.7390 1.8882 1.35 0.1136 0.2375 0.3679 0.5031 0.6389 0.7742 0.9076 1.0369 1.1591 1.2748 1.4873 1.6702 1.8251 1.40 0.1035 0.2148 0.3351 0.4606 0.5870 0.7134 0.8388 0.9612 1.0778 1.1892 1.3975 1.5839 1.7488 1.45 0.0936 0.1945 0.3003 0.4119 0.5250 0.6409 0.7580 0.8743 0.9S74 1.0973 1.3067 1.4967 1.6648 1.50 0.0849 0.1797 0.2799 0.3855 0.4925 0.5997 0.7063 0.8114 0.9137 1.0134 1.2128 1.3945 1.5560 1.55 0.0782 0.1657 0.2585 0.3567 0.4565 0.5564 0.6560 0.7540 0.8495 0.9426 1.1222 1.2909 1.4495 1.60 0.0717 0.1522 0.2379 0.32S7 0.4214 0.5143 0.6070 0.6983 0.7875 0.8747 1.0436 1.2039 1.3741 1.65 0.0660 0.1404 0.2198 0.3043 0.3907 0.4777 0.5646 0.6504 0.7346 0.8171 0.97S1 1.1920 1.4096 1.70 0.0615 0.1308 0.2052 0.2846 0.3661 0.4485 0.5311 0.6132 0.6939 0.7733 0.9513 1.1596 1.3652 1.75 0.0580

0. 1235 0.1939 0.2695 0.3474 0.4265 0.5063 0.5959 0.6644 0.7418 0.8938 t.0601 1.2441 1

.4.

4



+

4

- +

4 4

4 1.80 0.0554

0. 1177 0.185 1 0.2578 0.3331 0.4099 0.4879 1 0.5659 0.6428 { 0.7188 0.8681 1.0131 1.1539 1 1.85 0.0532 0.1128 0.1776 0.2478 0.3212 0.3964 0.4730 0.5495 0.6250 0.6996 0.8465 0.9897 1.1294 1.90 0.0517 0.1087 0.1705 0.2387 0.3103 0.3839 0.4588 0.5336 0.6075 0.6805 0.8248 0.9659 1.1045 1.95 0.0502 0.1054 0.1646 0.2300 0.2993 0.3706 0.4433 0.5161 0.5881 0.6593 0.8002 0.9388 1.0758 2.00 0.0483 0.1015 0.1582 0.2207 0.2871 0.3556 0.4257 0.4961 0.5657 0.6347 0.7718 0.9072 1.0419 2.05 0.0460 0.0969 0.1509 0.2102 0.2733 0.3386 0.4058 0.4733 0.5403 0.6068 0.7394 0.8709 1.0025 2.10 0.0435 0.0916 0.1427 0.1986 0.2581 0.3200 0.3838 0.4482 0.5123 0.5761 0.7036 0.8307 0.9583 2.15 0.0423 0.0867 0.1338 0.1862 0.2419 0.3002 0.3605 0.4216 0.4826 0.5434 0.6654 0.7874 0.9104 2.20 0.0410 0.0840 0.1281 0.1733 0.2253 0.2798 0.3365 0.3941 0.4519 0.5096 0.6257 0.7423 0.8601 2.25 0.0396 0.0812 0.1238 0.1670 0.2101 0.2594 0.3124 0.3666 0.4209 0.4755 0.5854 0.6962 0.8087 2.30 0.0382 0.0782 0.1194 0.1611 0.2029 0.2445 0.2887 0.3394 0.3904 0.4416 0.5452 0.6501 0.7574 2.35 0.0367 0.0752 0.1148 0.1551 0.1955 0.2359 0.2761 0.3160 0.3606 0.4086 0.5058 0.6049 0.7074 2.40 0.0353 0.0723 0.1103 0.1491 0.1882 0.2274 0.2665 0.3053 0.3437 0.3817 0.4677 0.5612 0.6692 2.50 0.0324 0.0665 0.1017 0.1378 0.1742 0.2108 0.2477 0.2844 0.3207 0.3568 0.4283 0.5035 0.6052 2.60 0.0298 0.0613 0.0939 0.1273 0.1613 0.1955 0.2300 0.2645 0.2987 0.3326 0.4002 0.4669 0.5440 2.70 0.0275 0.0566 0.0868 0.1179 0.1495 0.1815 0.2136 0.2459 0.2779 0.3097 0.3732 0.4361 0.4984 2.80 0.0254 0.0523 0.0804 0.1094 0.1389 0.1686 0.1986 0.2287 0.2586 0.2884 0.3479 0.4070 0.4658 2.90 0.0235 0.0485 0.0746 0.1016 0.1291 0.1568 0.1848 0.2128 0.2408 0.26S7 0.3246 0.3802 0.4357 3.00 0.0217 0.0450 0.0693 0.0945 0.1201 0.1459 0.1721 0.1983 0.2246 0.2508 03033 0.3557 0.4084 3.10 0.0202 0.0418 0.0644 0.0879 0.1117 0.1359 0.1604 0.1851 0.2098 0.2345 0.2840 0.3337 0.3837 3.20 0.018O 0.0388 0.0599 0.0818 0.1041 0.1267 0.1498 0.1731 0.1964 0.2197 0.2667 0.3139 0.3616 3.30 0.0175 0.0362 0.0558 0.0761 0.0970 0.1183 0.1401 0.1621 0.1842 0.2064 0.2510 0.2960 0.3416 3.40 0.0164 0.0337 0.0520 0.0710 0.0905 0.1106 0.1313 0.1522 0.1732 0.1942 0.236S 0.2798 0.3235 3.50 0.0154 0.0317 0.0485 0.0662 0.0846 0.1037 0.1233 0.1432 0.1631 0.1832 0.2238 0.2650 0.3070 3.60 0.0145 0.0298 0.0456 0.0622 0.0796 0.0975 0.1161 0.1349 0.1539 0.1731 0.2119 0.2515 0.2919 3.70 0.0137 0.0281 0.0430 0.0587 0.0750 0.0919 0.1094 0.1274 0.1455 0.1638 0.2009 0.2390 0.2779 3.80 0.0129 0.0265 0.0406 0.0554 0.0708 0.0868 0.1034 0.1205 0.1377 0.1552 0.1908 0.2274 0.2649 3.90 0.0122 0.0251 0.0383 0.0523 0.0669 0.0821 0.0979 0.1141 0.1305 0.1472 0.1814 0.2166

-0.2527 4.00 0.0115 0.0237 0.0362 0.0495 0.0634 0.0779 0.0929 0.1083 0.1240 0.1400 0.1727 0.2066 0.2412 4.10 0.0109 0.0224 0.0343 0.0469 0.0601 0.0739 0.0882 0.1030 0.1180 0.1332 0.1646 0.1970 0.2302 4.20 0.0103 0.0212 0.0325 0.0445 0.0571 0.0702 0.0839 0.0979 0.1123 0.1268 0.1568 0.1878 0.2196 4.30 0.0097 0.0200 0.0308 0.0422 0.0542 0.0667 0.0798 0.0932 0.1068 0.1207 0.1493 0.1789 0.2093 4.40 0.0092 0.0189 0.0291 0.0401 0.0515 0.0634 0.0758 0.0886 0.1016 [ 0.1149 0.1421 0.1704 0.1994

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 84 of 349 Date: 08/27/03 4.50 0.0087 0.0179 0.0276 0.030 S

0.0490 0.0603 0.0721 0.0843 0.967 0.1093 0.1352 0.1622 0.1899 4.60 0.0082 0.0170 0.0262 0.0361 0.0465 0.0573 0.0686 0.0801 0.0919 0.1039 0.1286 0.1542 0.1807 4.70 0.0077 0.0160 0.0248 0.0343 0.0442 0.0545 0.0652 0.0761 0.0873 0.09+/- 7 0.1222 0.1466 0.171g 4.80 0.0073 0.0152 0.0235 0.0325 0.0420 0.0517 0.0619 0.0723 0.030 0.0938 0.1160 0.1392 0.1633 4.90 0.0068 0.0143 0.0223 0.0308 0.0398 1 0.0491 00588 0-06R7 0.0787 1 0-.090 0 1101 1 0.1322 1 0.1 551 I 5.00 0.0064 0.0135 0.0211 0.0292 0.0378 0.0466 0,0558 0.0652 0.0747 0.0844 0.1045 0.1254 0.1473 5.10 0.0063.

0.0128

.0.0199.

. 0.0277 0.03M58. 0.p442.

0.0529 0.0618.

0.0708 0.000 0.0990 0.1189 0.1398 5.20 0.0061 0.0120 0.018S 0.0262 0.0340 0.0419 0.0502 0.0586 0.0672 0.0759 0.0939 0.1128 0.1326 5.40 0.005S 0.0115 0.0169 0.0235 0.0304 0.0376 0.0450 0.0326 0.0602 0.06E1 0.0842 0.1013 0.1193 5.60 0.0055 0.0108 0.0160 0.0209 0.0272 0.0337 0.0403 0.0471 0.0540 0.0610 0.0755 0.0909 0.1073 5.80 0.0051 0.0102 0.0152 0.0204 0.0257 0.0310 0.0363 0.0421 0.0483 0.0546 0.0677 0.0816 0.0965 6.00 0.0050 0.0100 0.0151 0.0202 0.0252 0.0302 0.0353 0.0403 0.0454 0.0504 0.0607 0.0733 0.0868 6.20 0.0049 0.0099 0.0150 0.0201 0.0253 0.0303 0.0353 0.0402 0.0449 0.0496 0.0592 0.0694 0.0798 6.40 0.0046 0.0094 0.0143 0.0192 0.0241 0.0290 0.0338 0.0385 0.0432 0.0478 0.0571 0.0671 0.0773 6.60 0.0042 0.0086 0.0131 0.0176 0.0222 0.0267 0.0312 0.0356 0.0399 0.0442 0.0533 0.0628 0.0725 6.80 0.0039 0.0079 0.0119 0.0161 0.0203 0.0245 0.0287 0.0329 0.0371 0.0413 0.0500 0.0589 0.0682 7.00 0.0036 0.0073 0.0110 0.0147 0.0186 0.0225 0.0264 0.0303 0.0342 0.0382 0.0463 0.0547 0.0634 7.20 0.0035 0.0070 0.0106 0.0142 0.0177 0.0212 0.0246 0.0280 0.0313 0.0349 0.0424 0.0502 0.0584 7.40 0.003Ty:- 0.0067 0.0102

-0.0136 0.0171 0U204 0.0237 0.0269 0.0300 0.0331 Oe=~9.

0.0457 0.0533,.

7.60 0.0032 0.0065 0.0098 0.0131 0.0164 0.0196 0.0228 0.0258 0.02S8 0.0318 0.0376 0.0433 0.0490 7.80 0.0031 0.0062 0.0094 0.0126 0.0158 0.0188 0.0218 0.0248

-. 0276 0.0305 0.0360 0.0415 0.0470 8.00 0.0029 0.0060 0.0090 0.0121 0.0151 0.0181 0.0210 0.0238

-0.0265 0.0292 0.0345 0.0398 0.0451 8.50 0.0027 0.0054 0.0082 0.0109 0.0137 0.0163 0.0189 0.0215 0.0239 0.0264 0.0312 0.0359 0.040S 9.00 0.0024 0.0049 0.0074 0.0099 0.0123 0.01 0.0171 0.0194 0.0216 0.0238 0.0282 0.0325 0.0369 9.50 0.0022 0.0044 0.0067 0.0089 0.0111 0.0133 0.0154 0.0175 0.0196 0.0216 0.0256 0.0295 0.0336 10.00 0.0020 0.0040 0.0060 0.0081 0.0101 0.0121 0.0140 0.0159 0.0177 0.0196 0.0232 0.0269 0.0306

Calc Number: GEO.HIBIP.03.02 Rev Number: 0 Sheet Number: 85 of 349 Date: 08/27/03 Table 6-12a. Soil Spectra for M=7.8, Set 1, Hicaher Vs Soil Profile 0.01_

0.1769 0.2903 0.4-323 0.5700 0.6950 0.8.046 0.9015 0.9846 1.0476 I.O87 1.1142 1.2258

-L13035 0.03 0.1835 0.2973 0.4440 0.5825 0.7080 0.8175 0.9137 0.9960 1.0580 1.0973 1.1211 1.2.322

-1.3098 0.06 0.2792 0.4274 0.5254 0.6210 0.7486 0.8602 0.9559 1.0381 1.0985 1.1339 1.1545 1.2552 11.3320 0.07 0.2790 0.4874 0.6178 0.6975 0.8200 0.9254 1.0114

-1.0870 1.1396 1.1702 1.1809 1.2678 -11.3428, 0.08 0.3147 0.4722 0.6527 0.8075 0.9342 1.0354 1.12 1.1841 1.2291 1.2502 1.2412 1.2846 11.3561 0.09 0.3926 0.6077 0.8057 0.9273 1.0007 1.0556 1.0800 1.0961 1.1593 1.1970 1.2622 1.3497 11.4058 0.10 0.3903 0.6525 0.8355 0.9763 1.0591 1.1249 1.1542 1.1998 1.2603 1.2924 1.3267 1.4018 11.4564 0.11 0.4578 0.6859 0.7865 0.9791 1.1227 1.2264 1.3191 1.4035 1.4547 1.4732 1.4314 1.4312 11.4208 0.12 0.3439 0.5525 0.7848 1.0116 1.1751 1.2942 1.3994 1.4954 1.5518 1.5621 1.5049 1.4989 11.4818 0.13 0.3913 0.6594 0.8788 1.0443 1.1,611 1.27~05 1.3831 1.4716 1.4874 1.4413 1.3762 1.3971 11.41 17 0.14 0.4340 0.-7485 1.0044 1.1616 1.2765 1.3730 1.4687 1.5133 1.5619 1.5903 1.5695 1.5610 11.5388-0.15 0.3919 0.7390 0.9860 1.1895 1.3701 11.4439 1.6113 1.7504 1.8219 1.8421 11.7670 1.7264 1.7119 0.16 0.4634 0.8462 1.1479 1.3488 1.4686 1.5370 1.6155 1.7438 1.8097 1.8118 1.8416 1.9 i74 1.9222

'O.17 0.5493

-O.'8688 1.1860 1.4069 1:5729 1.7926 ~L§3074r 2.0070 1.9836~ 1.9224

1. 8722; 1.8756 1.9191 0.18 0.5408 0.9191 1.2500 1.4928 1.6398 1.7039 1.7572 1.8692 1.9055 1.9008 1.8856 1.8985 1.8444 0.19 0.5242 0.9429 1.2983 1.5628 1.7197 1.7854 1.8196 1.8999 2.0194 2.1148 2.1840 2.12-78 11.9589 0.20 0.5382 0.9727 1.3738 1.7596 1.9280 1.9465 1.9147 1.9832 2.1337 2.2605 2.3824 2.3600 2.2087 0.21 0.5742 1.0858 1.6258 2.0557 2.2463 2.2747 2.2704 2.3145 2.3696 2.4078 2.4246 2.4354 2.3601 0.22 0.5349 1.0153.1.4597 1.8542 2.1477 2.3220 2.4320 2.5166 2.5826 2.6265 12.6368 2.6546 2.5887 0.23 0.4690 0.9507 1.4280 1.7706 2.0177 2.2106 2.3749 2.4696 2.5563 2.6035 12.6123 2.6-279 2.5717 0.24 0.5033 1.0896 1.6424-2.0611 2.3180 2.4855 2.6314 2.7156 2.7801 2.7805 2.6685 2.6774 2.6266 0.25 0.4582 1.0045 1.5430 1.9672 2.2444 2.6154 2.9163 3.1002 3.1489 3.0858 2.8752 2.8351 12.7427 0.26 0.4421 0.8484 1.3362 1.8660 2.3429 2.7561 3.1048 3.3446 3.4420 3.4143 3.1364 2.8462 2.7956 0.27 0.4279 0.8139 1.2495 1.7653 2.2408 2.6643 3.0395 3.3118 3.4473 3.4570 3.2404 2.9689 2.8153 0.28 0.4213 0.7979 1.1523 1.6037 2.0699 12.4966 2.8812 3.1770 3.3444 3.3889 3.2349 3.1540 3.0401 0.29 0.4168 0.7930 1.1432 1.4871 1.8262 2.2398 2.6203 2.9227 3.1529 3.3280 3.4975 3.5431 3.3891 0.30 0.4029 0.7691 1.1074 1.4365 1.7631 2.0811 2.3878 2.8157 3.1130 3.2577 3.3450 3.5213 13.5982 0.31 0.4032 0.7639 1.0877 1.4054 1.1189 2.0276 2.3220 2.5714 2.7702 3.0434 3.4117 3.6981 13.7798 0.32 0.3904 0.7563 1.0835 1.3895 1.7016 2.0112 2.3118 2.5776 2.7692 2.9814 3.3126 3.5775 3.6462 0.33 0.3770 0.7296 11.0519 1.3561 1.6586 1.9651 2.2695 2.5379 2.7366 2.*88463 2.9546 3.1800 3.2392 0.34 0.3852 0.7054 11.0182 1.3105 1.6012 1.8951 2.1901 2.4560 2.6510 2.7584 2.7911

-2.9144

'2.9987 0.35 0.3975 0.7031 10.9981 1.2805 1.5573 1.8396 2.1228 2.3813 2.5717 2.6742 2.7050 2.8326 2.9350 0.36 0.3929 0.7058 1.0088 1.2854 1.5540 1.8304 2.1103 2.3671 2.5585 2.6628 12.7000 2.8461 2.9861 0.37 0.3861 0.7148 1.0178 1.2917 1.5580 1.8303 2.1155 2.3775 2.5804 2.6957 12.7539 2.9328 3.1126 0.38 0.4342 0.8074 1.0784 1.2935 1.5232 1.7902 2.0718 2.3379

'2.5455 2.6702 2.7492 12.9481 13.1495 0.39 0.4829 0.8929 1.1799 1.4246 1.5958 1.7759 2.0226 12.2879 2.4979 2.6284 12.7215 12.9366 13.1582 0.40 0.4913 0.9031 1.2634 1.5256 1.7006 1.8326 1.9811 12.2241 2.4387 2.5771 12.6918 12.9313 13.2453 0.41 0.4544 0.9032 11.2754 1.5448 1.7293 1.8643 2.0059 2.1578 2.2879 2.4353 12.5759 12.9532 13.3559 0.42 0.4234 0.8458 1.2046 1.4797 1.6781 1.8063 1.9700 2.1319 2.2199 2.2228 2.4110 12.8059 3.2364 0.43 0.3781 0.7825 1.1627 1.4703 1.6848 1.8248 1.9550 2.1357 2.2447 2.2568 2.2067 12.5512 2.9867 0.44 0.3524 0.7517 1.1294 1.4339 1.6523 1.7855 1.9593 2.1530 2.2768 2.3018 2.1469 2.3481 2.7246 0.45 0.3292 0.7091 1.0783 1.3839 1.6082 1.7554 2.0012 2.2078 2.3420 2.3757 2.2316 2.327 2I589 0.46 0.2977 0.6480 0.9978 1.2936 1.5170 1.7968 2.0529 2.2693 2.4128 2.4544 2.3216 2.3349 250 0.47 0.2800 0.5990 0.9316 1.2464 1.5408 1.8280 2.0904 12.3118 2.4625 2.5116 2.3942 2.4186 2.5466 0.48 0,2756 0.5871 0.9100 1.2282 1.5365 1.8217 2.0829 12.3056 2.4591 2.5161 2.4193 2.4584 2.5336 0.49 0.2635 0.5621 0.8743 1.1820 1.4768 1.7480 1.9967 12.2107 2.3654 2.4330 2.3690 2.4232 2.5012 0.50 0.2442 0.5207 0.8119 1.0967 1.3666 1.6141 1.8439 12.0470 2.2017 12.2838 2.2595 2.3258 2.4054 0.51 0.2256 0.4799 10.7480 1.0095 1.2558 1.4827 1.6974 11.8964 2.0574 2.1569 2.1663 2.2391 2.3147 0.52 0.2148 0.4551 0.7091 0.9573 1.1920 1.4121 1.6261 1.8307 2.0044 2.1208 2.1503 2.2228 2.2934 0.53 0.2141 0.4441 0.6929 0.9383 1.1729 1.3970 1.6187 1.8339 2.0213 2.1498 2.1865 2.2582 2.3256 0.54 0.2177 0.4382 0.6843 0.9305 1.1680 11.3968 1.6269 1.8499 2.0479 2.1848 2.2295 2.3013 2.3675 0.55 0.2229 0.4410 0.6771 0.9242 1.1645 11.3984 1.6344 1.8656 2.0731 2.2199 12.2734 2.3461 12.4108 0.56 0.2312 0.4474 0.6881 0.9305 1.1678 1.4082 1.6519 1.8928 2.1117 2.2698 2.3313 2.4026 2.5198 0.57 0.2413 0.4675 0.7006 0.9522 1.1962 1.428!1 1.6684 1.9181 2.1476 2.3168 2.4673 2.5999 2.6500 0.58 0.2476 0.4843 10.7127 0.9531 1.2062 1.4500 1.6906 1.9227 2.1314 2.3669 2.6957 2.8593 2.971J 0.60 0.2295 0.4595 0.6880 0.9142 1.1354 1.3491 -1.5606 1.8220 2.1410 2.4422 2.8019 3.0141 3.157 0.62 0.2172 0.4229 0.6260 0.8287 1.0463 1.2764 1.5091 1.7472 2.0007 2.2938 2.7824 3.0996 3.303 0.64 0.2232 0.4344 0.6423 0.8492 11.0485 j 1.2423 1.49706 1.7493.

2.0234 2.3131 12.8081 3.1574 3.4008 0.66 0.2278.

0.4433 0.6549 0.8649 11.0668_

1.2596 1.4499 F1.6743 1.9429

-2.2237 12.7103 3.0691 1337

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 86 of 349 Date: 08/27/03 0.68 0.2319 0.4509 0.6656 0.8783 1.0823 1.2775 1.4698 1.6590 1.8350 1.9905 2.4395 2 7820 3.0670

}.701 0.2353 0.4576 0.6752 0.8902 1.0961 1.2928 1.4870 1.6787 1 1.8571 2.0121 2.3217 2.6624 2.9542 0.72 0.2390 0.4617 0.6809 0.8975 1.1046 1.3026 1.4980 1.6910 1.8711 2.0283 2.2978 2.6546 2.96J 1 0.74 0.2461 0.4650 0.6814 0.8979 1.1047 1.3021 1.4973 1.6905 1 1.8713 2.0299 2.2G31 2.4787 2.757 0.76 1 0.2506 1 0.4749 1 0.6834 I O.8907 1.0958 1.2916 l 1.4849 1.6762 1 1.8558 2.0138 l 2.2487 1 2.4665 1 2.6620 1 0.78 0.2532 0.4810 0.6933 0.8925 1.0802 1.2729 1.4631 1.6517 1.8287 1.9853 2.2197 2.4360 2.6309 0.80 0.2546 0.4849.-

0.6998 0.9013 1.0801...

1.2503 1.4368..

1.6214 J1.7948 1.1.9490..

2.1813 2.3958 2.5890 0.82 0,2351 0.4873 0.7043 0.9079 1.0882 1.2477 1.4082 1.5887 1.7588 1.909-7 2.1391 2.3510 2.5416 0.84 0.2548 0.4883 0.7071 0.9126 1.0946 1.2548 1.4063 1.5553 1.7214 1.8692 2.0954 2.3036 2.4915 0.86 0.2537 0.4879 0.7082 0.9153 1.0993 1.2607 1.4119 1.5584 1.6905 1.8274 2.0498 2.2542 2.4439 0.88 0.2519 0.4863 0.7076 0.9163 1.1021 1.2652 1.4167 1.5616 1.6903 1.8024 2.0029 2.2068 2.4105 0.90 0.2510 0.4837 0.7057 0.9155 1.1031 1.2681 1.4204 1.5646 1.6906 1.7975 1.9810 2.1785 2.3749 0.92 0.2530 0.4884 0.7083 0.9132 1.1023 1.2689

.1.4226 1.5667 1.6909 1.7937 1.9641 2.1511 2.3389 0.94 0.2547 0.4945 0.7198 0.9306 1.1145 1.2712 1.4229 1.5677 1.6909 1.7905 1.9490 2.1257 2.3043 0.96 0.2560 0.4993 0.7293 0.9452 1.1352 1.2984 1.4456 1.5798 1.6902 1.7877 1.9359 2.1028 2.2718 0.98 0.2565 0.5025 0.7361 0.9564 1.1511 1.3196 1.4720 1.6115 1.7223 1.7958 1.9240 2.0818 2.2417 1.00 0.2561 0.5035 0.7396 0.9630 1.1616 1.3345 1.4911 1.6348 1.7497 1.8275 1.9122 2.0613 2.2123 1.05 0.2521 0.5029 0.7448 0.9747 1.1786 1.3529 1.5063 1.6530 1.7748 1.8602 1.9351 2.0145

'2.13 13 1.10 -0.2402 0.4923

.0;74410:

'~0.9888 11.2116

.1s4061 1.5777 1R7294 1.8449 1.9 154

.1.9517 2.0085

--2.0660 1.15 0.'22603 0.4691 0.7155 0.9586 1.1844 1.3855 1.5648 1.7248 1.8497 1.9307 1.9845 2.0463 2.1016 1.20 0.2089 0.4413 0.6856 0.9337 1.1708 1.3X48 1.5737 1.7409 1.8822 1.9770 2.0439 2.1099 2.1629 1.25 0.1788 0.3808 0.5974 0.8223 1.0447 1.2542 1.4449 1.6163 1.7546 1.8487 1.9140 2.0111 2.1184 1.30 0.1479 0.3150 0.4954 0.6848 0.8749 1.0586 1.2721 1.4769 1.6661 1.8283 2.0376 2.1975 2.3287 1.35 0.1286 0.2725 0.4302 0.6001 0.7812 0.9797 1.1921 1.4044 1.6122 1.8043 2.1093 2.3081 2.4587 1.40 0.1304 0.2740 0.4321 0.6048 0.7944 11.0006 1.2158 1.4349 1.6543 1.8646 2.1887 2.4199 2.5776 1.45 0.1273 0.2653 0.4145 0.5768 0.7537 0.9451 1.1454 1.3512 1.5605 1.7668 2.:1092 2.3664 2.5535 1.50 0.1221 0.2555 0.3983 0.5517 0.7183 0.8985 1.0875 1.2829 1.4855 1.6916 2.0531 2.3315 2.5408 1.55 0.1171 0.460 0.3847 0.5337 0.6950 0.8699 1.0540 1.2455 1.4460 1.6536 2.0279 2.3199 2.5444 1.60 0.1109 0.2341 0.3673 0.5106 0.6662 0.8353 1.04 1.2006 1.3968 1.6009 1.9735 2.2705 2.5056 1.65 0.1033 0.2181 0.3425 0.4764 0.6221 0.7806 0.9486 1.1246 1.3105 1.5052 1.8677 2.1995 2.4851 1.70 0.0949 0.1977 0.3109 0.4332 0.5665 0.7117 0.8660

-1.0282 1.2010 1.3840 1.7434 2.1029 2.3990 1.75 0.0895 0.1868 0.2903 0.4009 0.5207 0.6505 0.7879 0.9331 1.0925 1.2637 1.6093 1.9574 2.2520 1.80 0.0840 0.1758 0.2738 0.3782 0.4911 0.6133 0.7426 0.8781 1.0227

1. 1767 1.4928 1.7911 2.0718 1.85 0.0785 0.1653 0.2585 0.3579 0.4651 0.5811 0.7038 0.8327 0.9708 1.1195 1.4208 1.7024 1.9760 1.90 0.0734 0.1547 0.2430 0.3377 0.4399 0.5505 0.6675 0.7905 0.9230 1.0668 1.3630 1.6304 1.8798 1.95 0.0695 0.1442 0.2255 0.3144 0.4110 0.5158 0.6268 0.7437 0.8701 1.0081 1.2952 1.5562 1.8000 2.00 0.0683 0.1414 0.2186 0.3008 0.3897 0.4856

.0.5864 0.6917 0.8061 0.9364 1.2091 1.4588 1.6938 2.05 0.0663

0. 13'74 0.2124 0.2919 0.3776 0.4699 0.5671 0.6687 0.7773 0.8941 1.1351 1.3637 1.5890 2.10 0.0632 -0.1313 0.2032 0.2794 0.3614 0.4497 0.5428 0.6400 0.7440 0.8562 1.0892 1.3107 1.5293 2.15 0.0594 0.1237 0.1917 0.2640 0.3418 0.4257 0.5140 0.6064 0.7054 0.8124 1.0361 1.2492 1.4598 2.20 0.0553 0.1154 0.1794 0.2474 0.3207 0.3999 0.4835 0.5710 0.6648 0.7666 0.9807 1.1850 1.3874 2.25 0.0512 0.1073 0.1671 0.2309 0.2999 0.3745 0.4533 0.5361 0.6250 0.7218 0.9265 1.1222 1.3164 2.30 0.0484 0.0999 0.1554 0.2152 0.2800 0.3503 0.4247 0.5030 0.5873 0.6794 0.8751 1.0626 1.2491 2.35 0.0464 0.0959 0-1475 0.2010-0.2614 0.3276 0.3978 0.4718 0.5519 0.6395 0.8267 1.0065 1.1860 2.40 0.0446 0.0922 0.1420 0.1940 0.2487 0.306-2 0.3724

-0.4424 0.5183 0.6017 0.7808 0.9533 1.1266 2.50 0.0421 0.0868 0.1341 0.1835 0.2352 0.2894 0.3454 0.4031 0.4635 0.5303 0.6940 0.8534 I1.0156 2.60 0.0399 0.0821 0.1268 0.1735 0.2224 0.2737 0.3266 0.3811 0.4383 0.4985 0.6204 0.7610 0.9117 2.70 0.0378 0.0776 0.1196 0.1637 0.2099 0.2584 0.3084 0.3599 0.4139 0.4709 0.5865 0.6960 0.8142 2.80 0.0358 0.0734 0.1130 0.1547 0.1984 0.2442 0.2915 0.3403 0.3913 0.4453 0.5551 0.6592 0.7618

'2.90 0.0340 0.0697 0.10-73 0.1468 0.1883 0.2318 0.2768 0.3231 0.3716 0.4229 0.3276 0.6272 0.7254 3.00 0.0326 0.0666 0.1024 0.1401 0.1797 0.2212 0.2642 0.3085 0.3548 0.4038 0.5042 0.6000 0.6947 3.10 0.0313 0.0639 0.0981 0.1341 0.1721 0.2119 0.2532 0.2957 0.3402 0.3873 0.4840 0.5767 0.6687 3.20 0.0302 0.0614 0.0940 0.1286 0.1650 0.2033 0.2429 0.2838 0.3266 0.3720 0.4656 0.5556 0.6452 3.30 0.0290 0.0590 0.0901 0.1230 0.1579 0.1946 0.2326 0.2719 0.3132 0.3569 0.4475 0.5349 0.6222 3.40 0.0277 0.0564 0.0860 0.1172 0.1504 0.1854 0.2218 0.2595 0.2991 0.3410 0.4284 0.5131

.0.5981 3.50 0.0263 0.0536 0.0816 0.1109 0.1423 i0.1755 0.2101 0.2460 0.2838 0.3239 0.4079 0.4895 0.5717 3.60 0.0248 0.0504 0.0,768 0.1042 0.1335 0.1648 0.1974 0.2313 0.2671 0.3052 0.3854 0.4635 0.5426 3.70 0.0230 0.0470 0.0715 0.0970 0.1242 0.1533 0.1838 0.2156 0.2492 0.285 1 0.3610 0.4353 0.5108 3.80 0.0217 0.0439 0.0664 0.0894 0.1144 0.1412 0.1694 0.1989 0.2302 0.2638 0.3352 0.4052 0.4768 3.90 0.0210 0.0425 0.0645 0.0869 0.1101 0.1342 0.1593 0.1853 0.2126 0.2418 0.3083 0.3739 0.4411 4.00 0.0203 0.0408 0.0616 0.0830 0.1049 0.1278 0.1516 01764 0.2025 0.2302 0.2872 0.3420 0.4048 4.10 0.0191 0.0385 0.0582 0.0784 0.0991 0.1206 0.1427 0.1656 0.1898 0.2160 0.2713 0.3241 0.3746 4.20 0177J 0.0356 0.0539 0.0727 0.0920 0.1119 0.1325 0.1538 0.1763 0.2007 0.2531 0.3038 0.3527 4.30 0.13 0.0325 0.0491 0.0662 0.0838 0.1021 0.1211 0.1406 0.1614 0.1838 0.2329 0.2807 0.3273 4.40 00 ~~64 0.0329 0.0496 0.0665 0.0836 0.1010 0.1185 0.1362

-0.1541 1 0.1724 0.2115 0.2561 0.3001

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 87 of 349 Date: 08/27/03 j

_L I

4.50 I nni#,

nn-t-A I oAn~n4 0 0676 I nS n

a a.I o l -f I

4 I 0 1 i I 1SR I

5 I

I 0.1755 I (1239 I 0.2527 1 0.2930 1 4.60 0.0161 0.0324 0.0489 0.0655 0.0823 0.0994 0.1166 0.1341 0,1520 0.1702 0.2079 0.2458 0.2847 4.70 0.0149 0.0301 0.0453 0.0607 0.0764 0.0922 0.1082 0.1244 0.1409 0.1579 0.1931 0.2286 0.2649 4.80 0.0135 0.0273 0.0413 0.0555 0.0700 0.0847 0.0995 0.1143 0.1292 0.1440 0.1732 0.2039 0.2364 4.90 0.0133 0.0269 0.0407 0.0548 0.0693 0.0840 0.0989 0.1138 0.1289 0.1440 0.1741 0.2040 0.2346 5.00 0.0128 0.0259 0.0392 0.0529 0.0669 0.0813 0.0958 0.1105 0.1254 0.1405 0.1709 0.2008 0.2313 5.10 0.0125.

0.0252.

0.0379.O.OQ6 0.0640 0.0777 0.0917 0.1059 0.1205 0.1354 0.1657 0.1953 0.2253 5.20 0.0122 0.0246 0.0371 0.0496 0.0621 0.0747 0.0876 0.1012 0.1151 0.1295 0.1591 0.1382 0.2176 5.40 0.0113 0.0228 0.0345 0.0464 0.0583 0.0703 0.0822 0.0942 0.1063 0.1184 0.1440 0.1710 0.1982 5.60 0.0102 0.0208 0.0316 0.0425 0.0536 0.0648 0.0761 0.0874 0.0987 0.1103 0.1336 0.1567 0.1794 5.80 0.0093 0.0188 0.0286 0.0387 0.0489 0.0593 0.0698 0.0803 0.0910 0.1019 0.1241 0.1461 0.1680 6.00 0.0085 0.0171 0.0260 0.0351 0.0445 0.0541 0.0639 0.0738 0.0838 0.0941 0.1151 0.1361 0.1571 6.20 0.0081 0.0161 0.0241 0.0324 0.0410 0.0498 0.0588 0.0680 0.0774 0.0872 0.1073 0.1274 0.1476 6.40 0.0078 0.0156 0.0235 0.0314 0.0394 0.0474 0.0555 0.0637 0.0719 0.0810 0.1000 0.1190 0.1382 6.60 0.0081 0.0163 0.0245 0.0327 0.0410 0.0494 0.0578 0.0662 0.0748 0.0834 0.1012 0.1193 0.1376 6.80 0.0081 0.0162 0.0244 0.0326 0.0409 0.0493 0.0576 0.0661 0.0745 0.0831 0.1007 0.1185 0.1367 7.00 0.0078 0.0156 0.0235 0.0314 0.0394 0.0474 0.0555 0.0636 0.0718 0.0800 0.0968 0.1138 0.1311 7.20 0.0073 0.0146 0.0220 0.0293 0.0368 0.0443 0.0518 0.0593 0.0670 0.0749 0.0910 0 1072 0.1234

.a.: {-'-7.40 0.0071 0.0143 0.0215.1 0-0287 1 0.0359 0.0432 U

-0.0505 0.057S9

.0.065a.

0.0729 1 0.0885 0.1044 1 0.1205

.~~~~~~~~

7.60 0.0068 0.0137 0.0205 0.0274 0.0344 0.0413 0.0483 0.0553 0,0623 0.0695 0.0842 0.0993 0.1147 7.80 0.0064 0.0128 0.0193 0.0257 0.0323 0.0388 0.0454 0.0519 0.0585 0.0651 0.0787 0.0927 0.1071 8.00 0.0059 0.0118 0.0178 0.0237 0.0298 0.0358 0.0419 0.0480 0.0541 0.0602 0.0726 0.0852 0.0983 8.50 0.0046 0.0092 0.0139 0.0186 0.0234 0.0282 0.0330 0.0379 0.0428 0.0478 0.0579 0.0680 0.0782 9.00 0.0038 0.0076 0.0115 0.0154 0.0193 0.0234 0.0274 0.0315 0.0357 0.0399 0.0487 0.0574 0.0664 9.50 0.0031 0.0063 0.0094 0.0125 0.0156 O.0186 0.0218 0.0250 0.0283 0.0317 0.0388 0.0459 0.0533 10.00 0.0025 0.0051 0,0076 0.0102 0.0127 0,0152 0.0178 1 0.0202 0.0227 0.0252 0.0304 0.0360 0.0422

Calc Number: GEO.H-BIP.03.02 Rev Number: 0 Sheet Number: 88 of '349 Date: 08/27/03

~~Table 6-12b. Soil Spectra for M=7.8, Set 2 Iiher Vs Soil Profile Per1 0.1668 0.2723 ]0.3910 10.4940

(.r68O 0.6155 0.6414 0.6627 0.19 0.7900 J 0.9427 1.0952 121 0.03 0.1716 0.2831 I0.3967 0.5009 10.5758 0.6231 0.6482 0.6714 0.7247 0.7948 10.9462 1.0963 1.2540 0.04 0.1898 0.3036 0.4030 0.5086 0.5835 0.6305 0.6552 0.6824 0.7292 0.7994 10.9496 1.0972 1.2561

-0.0t' 0.2210 0.3556 0.4387 0.5243 0.5998 0.6443 0.664S5-- --&z6925 0.7273.- 07995

.~0.9545

-1.0989

.142588 0.06 0.2445 0.3993 0.5009 0.5572 0.5969 0.6436 0.6779 0.7197 0.7402 0.7986 10.9560 11.1042 1.2592 0.07 0.2617 0.4336 0.5513 0.6321 0.7004 0.7367 0.7834 0.8129 0.8147 0.8265 10.9613 11.1004 1.2638 0.08 0.3075 0.5015 0.6318 0.7063 0.7562 10.7810 0.8122-0.8280 0.8438 0.8774 10.9484 11.1242 1.2745 0.09 0.3513 0.5825 10.7341 0.8473 0.9170 0.9628 0.9987 1.0123 1.0209 1.0448 11.1004 1.1372 1.30899 0.10 0.4339 0.5976 10.7183 0.8540 0.9547 1.0140 1.0569 11.0798 1.0932 1.1299 1.1989 1.2292 1.3024 0.11 0.4257 0.6464 10.763-6 0.8817 0.9795 1.0469 1.0937 11.1183 1.1431 1.1777 1.2514 1.2895 1.2906 0.12 0.4098 0.7319 10.9271 1.0019 1.0369 1.1141 1.1832 1.2014 1.2286 1.2657 1.3468 1.3868 133 0.13 0.4505 0.6741 0.8659 1.0817 1.2512 1.3692 1.4698 1.5240 1.5039 1.4732 1.4432 1.4945 1.4962 0.14 0.4682 0.7392 0.9224 1.1258 1.3006 1.4412 1.5599 1.6266 1.6185 1.5986 1.5036 1.4372 1.4831 0.15 0.4833 0.7788 0.9566 11.1501 1.3421 1.5059 1.6402 1.7078 1.7219 1.7089 11.6262 1.5085 1.4541!

0.16 0.4972 0.8133 0.9879 11.1689 1.3630 1.5432 1.6983 1.7895 11.810-5 1.8144 11.7436 1 1.6274 1.4886 0:r7 0.5111 0.8627 1.0273 1.1967'

`1:4028-1.6191 1.7807

-1.8737 1.9213

`1:9386 11.8-767 11.7698.- 1.6250 0.18 0.5474 0.9326 1.1946 1.3481 1.4.618 1.6258 1.8258 1.9572 2.0359 2.0698 12.0149 j1.9125 1.7711 0.19 0.5648 1.0612 1.3802 1.5798 1.7336 1.8648 1.9812 2.0410 2.0434 2.1246 2.2596 12.2838 2:.1967 0.20 0.5143 0.9930 1.3420 1.6014 1.7991 1.9631 2.1074 2.2025 2.2809 2.3653 2.5231 2.5722 2.5015 0.21 0.4973 0.9455 1.3058 1.5780 1.8022 1.9885 2.1461 2.2509 2.3346 2.4274 2.6057 2.6830 2.6391 02 05200 1.0072 1.~4~094 1.7197 1.9603 12.1448 2.2556 2.3221 2.4083 2.5083 2.7022 12.8036 2.7811 0.23 0-.-570 5 1.0915 1.5073 1.7886 2.0534 2.3351 2.5458 2.6080 2.5275 2.5813 2.8022 12.9271 2.9213 0.24 0.5315 1.0212 1.3970 1.6821 1.9199 2.2277 2.4735 2.5790 2.5356 2.6270 2.8659 3.0141 3.0325 0.25 0.4649 0.8959 1.3240 1.6303 1.9745 2.2599 2.4896 2.6229 2.6937 2.7156 2.9147 13.0881 3.1270 0.26 0.4513 0.8749 1.2643 1.6010 1.8874 2.1232 2.3224 2.4785 2.5829 2.6676 2.9443 3.1376 13.2003 0.27 0.4388 0.8525 1.2397 1.5817 1.8755 2.1174 2.4051 2.6000 2.7643 2.8763 2.9691 3.1849 13.2670 0.28 0.4271 0.8331 I1.2200 1.5653 1.8624 12.1162 2.4290 2.6476 2.8356 2.9668 3.0697 3.2133 13.3131 0.29 0.4154 0.8122 1.1958 1.5415 1.8439 2.0910 2.2845 2.4138 2.6094 2.7755 3.0018 3.2118 13.3296 0.30 0.4038 0.7890 1.1647 1.5064 1.8070 2.0527 2.2418 2.3639 2.4777 2.6028 2.9104 3.1585 13.2948 0.31 0.3937 0.7668 1.1315 1.4664 1.7574 1.99-72 2.1790 2.2956 2.3984 2.5206 2.8199 I3.0770 13.2359 0.32 0.3870 0.7505 1.1053 1.4295 1.7147 1.9453 2.1186 2.2263 2.3244 2.4389 2.7323 2.9992 3.1830 0.33 0.3846 0.7418 1.0891 1.4068 1.6852 1.9085 2.0747 12.1754 2.2691 2.3786 2.6728 I2.9525 3.1616 0.34 0.3852 0.7403 1.0817 1.3961 1.6695 1.8879 2.0494 12.1472-2.2357 2.3426 2.6416 2.9533 3.2909 0.35 0.3866 0.7407 1.0793 1.3902 1.6604 11.8782 2.0362 12.1298 2.2139 2.3193 2.6255 12.9360 3.2509 0.36 0.3873 0.7395 1.0759 1.3828 1.6530 11.8676 2.0224 12.1119 2.1915 2.2972 2.6091 12.9321 3.2058 0.37 0.4006 0.7368 1.0686 1.3738 1.6405 1.8511 2.0020 12.0867 2.1651 2.2688 12.5830 12.9158 13.2055 0.38 0.3924 0.7314 1.0596 1.3601 1.6226 1.8305 1.9766 2.0568 2.1295 2.2297 2.5445 12.8886 3.1920 0.39 0.4062 0.7650 1.0757 1.3441 1.6028 1.8048 1.9451 2.0185 2.0845 2.1813 2.4956 2.8473 3.1644 0.40 0.4074 0.7940 1.1404 1.4217 1.6280 1.7754 1.9087 1.9746 2.0333 2.1248 2.4362 2.7910 3.1208 0.41 0.4079 0.8160 1.1882 1.4973 1.7322 1.8734 1.9288 1.9214 1.9708 2.0555 2.3606

.2.7216 3.0621 0.42 0.4084 0.8256 1.2107 1.5350 1.7875 1.9442 2.0120 1.9899 1.9358 1.9716 12.2704 2.6303 12.9804 0.43 0.4019 0.8171 1.2007 1.5272 1.7842 1.9454 2.0207 2.0043 1.9601 1.9428 12.1574 2.181291 0.44 0.3845 0.7853 1.1536 1.4683 1.7192 1.8789 1.9510 11.9378 1.9029 1.8967 12.0201 2311279 0.45 0.3557 0.7312 1.1237 1.5013 1.8331 2.0515 2.1418 2.0969 11.9879 1.9329 12.0179 12210 25571 0.46 0.3475 0.7315 1.1483 1.5635 1.9201 12.1635 2.2771 2.2527 2.1635 2.1075 12.1456 12.3000 I 2.5860 0.47 0.3078 0.6603 1.0773 1.4775 1.8276 12.0783 2.2120 2.2170 2.1591 2.1293 12.2070 2.3250 12.4944 0.48 0.2740 0.5940 0.9573 1.3253 1.6545 11.9035 2.0685 2.0882 2.1132 2.1209 2.2251 2.3790 12.5491 0.49 0.2755 0.5818 0.9252 1.2696 1.6101 1.8924 2.0646 2.1310 2.1810 2.2015 2.3210 2.4924 2.6907 0.50 0.2563

~0.5404 0.8597 1.1793 1.4792 1.7244 1.9584 2.1106 2.1732 2.2062 2.3382 2.5163 2.7296 0.51 0.2372 0.4959 0.7809 1.0781 1.3800 1.6648 1.9069 12.0995 12.1971 2.2389 2.3290 2.4997 2.7188 0.52 0.2343 10.4875 10.7646 1.0513 1.3463 1.6465 1.9149 12.1179 12.2305 2.2884 2.4027 2.5005 2.7004 0.53 0.2319 0.4827 0.7635 1.0538 1.3519 1.6511 1.9235 2.1349 2.2614 2.3301 2.4660 12.5819 12.7068 0.54 0.2340 0.4848 0.7653 1.0540 1.3497 1.6487 1.9240 2.1441 2.2802 2.3578 2.5085 12.6435 12.7826 0.55 0.2370 0.4770 0.7529 1.0369 1.3273 11.6218 1.8964 2.1197 2.2625 2.3457 2.5087 12.6592 12.8138 0.56 I 0.2378 0.4657 0.7215 10.9942 1.2732 11.5568 1.8244 2.0456 2.1906 2.2771 2.4475 12.6108 12.7804 0.57 1 0.2397 0.4727 0.7178 10.9611 1.1951 11.4565 1.7096 1.9225 2.0651 2.1.523 2.3259 12.4988 12.6808 0.58 0.2494 0.4911 0.7256 0.9419 1.1451 1.3608 1.5704 11.7699 1.9557 2.1102 2.3479 12.5052 12.6437 0.60 0.2600 0.5195 0.7771 1.0191 1.2451 1.4681 1.6961 1.9312 2.1502 12.3227 2.5699 2.7115 2.8230 0.62 0.2297 0.4656 0.7054 0.9344 1.1502 J1.3620 1.5744 1.7893 1.9887 12.1430 2.4154 2.7055 12.9482 0.4 0.2123 0.4087 0.6075 0.8009 0.9928 1.1973 1.4131 11.6338 1.8450 12.0397 2.3973 2.691 2.9367 0.66 0.2304 0.4448 0.6462 0.8326 1.0100 j1.2251 1.4511 11.6808 1.8958 12.0879 2.4542 2.7936 13.1062

Calc Number: GEO.LBBIP.03.02 Rev Number: 0 Sheet Number: 89 of 349

______D ate: 08/27/03 0.68 3 0.2462 0.4776 0.6970 0.8992 ]1.0902 11.2822 1.47Z13 1.6481 1.8807 2.0910 2.4766 2.22 310 0.70--

0.2481 0.4843 0.7110 0.9195 1.1151 1.3119 1.5081 J1.6955

-1.8657 2.0229 2.3306 2.6385 J2.9383 0.72 0.2379 0.4662 0.6867 0.8894 1.0783 1.2669 1.4562 1.6384 1.8053 1.9579 2.25036 2.5167

'2.7725 0.74 0.2432 0.4762 0.7021 0.9093 1.1013 1.2916 1.4833 1.6704 1.8445 2.0053 2.3134 2.5959 2.8746 0.76 0.2511 0.4685 0.6905 0.8971 1.0877 1.2757 1.4662 1.6563 1.3378 2.0069 2.3273 2.6191 2.9069 0.78 0.2501 0.4684 0.6709 0.5858 1.0427 j1.2230 1.4055 1.5891 1.7671 1.9338 2.2458 2.5266 2.8019 0.80 0.2551 404804 10.6880 0.8719 1.0336 j1.2079 1.3880 1.5711 11.7516 1.9229 2.2420.

2.5300 2.8128 0.2

.28 0.~4720 0.6831 0.8734 1.0510 1.2108 1.3607 1.4986 1.6738 1

I

.3464

- -245712-.I.741 V 0.84 0.2514 0.4876 0.7135 0.9169 1.0967 1.2640 1.4214 1.5670 1.7000 1.8230 2.0515 2.2631 2.4998 0.86 0.2572 0.4988 0.7301 0.9391 1.1248 1.2987 1.4638 1.6177 1.7606 1.3948 2.1439 2.3711 2.6197 0.88 0.2464 0.4735 0.6957 0.8979 1.0789 1.2493 1.4121 1.5647 1.7081 1.8439 2.0946 2.3187 2.5576 0.90 0.2329 0.4481 0.6501 0.8424 1.0148 1.1775 1.3322 1.4776 1.6133 1.7427 1.9785 2.1855 2.4014 0.92 0.2415 0.4589 0.6615 0.3545 1.0276 11.1900 1.3440 11.4373 1.6208 1.7473 1.9788 2.1801 2.3879 0.94 0.2534 0.4894 0.7076 0.9012 1.0804 1.2480 1.4071 11.5545 1.6923 1.8241

-2.0672 2.2794 2.4970 0.96 0.2574 0.4975 0.7213 0.9164 1.0203 1.2437 1.4024 1.5506 1.6899 1.8244 2.0744 2.2935 2.5166 0.98 0.2625 0.5066 0.7248 0.9000 1.0498 1.1986 1.3313 1.4605 1.5949 1.7251 1.9675 2.1791 2.3923 1.00 0.2625 0.5074 0.7281 0.9057 1.0386 1.1801 1.3054 1.4128 1.5065 1.6304 1.8596 2.0582 2.2557 1.05 0.2564 0.5059 0.7426 0.9468 1.1262 1.2872 1.4244 1.5270 1.6165 1.7074 1.8727 2.0454 2.2340 1.10 0.2391.. 0.,4882 0.7351 0.9634.

1.1621 1.3363

  • .I4866 1.6027 1.6844 1.7507 1.8821 2.0228

-2.1626 1.15 0.2384 0.4911 0.7433 0.9768 1.1787 1.3542 1.5052 1.6232 1.7278 1.8370

.0280 2.1781 230 1.20 0.2035 0.4178 0.6369 0.8487 1.0396 1.2417 1.4462 1.6350 1.8039 u.1.9551 2.2210 2.4361 2.6229 1.25 0.1752 0.3700 0.5793 0.8040 1.0292 1.2475 1.4519 1.6327 1.7891 1.9479 2.2321 2.4688 2.6810 1.30 0.1632 0.3442 0.5409 0.7468 0.9531I 1.1563 1.3523 1.5439 1.7170 1.8798 2.1670 2.3908 2.5826 1.35 0.1497 0.3145 0.4897 0.6729 0.8725 1.0771 1.2868 1.4890 1.6746 1.8448 2.1520 2.3983 2.6018 1.40 0.1416 0.2959 0.4571 0.6361 0.8295 1.0286 1.2286 1.4272 1.6208 1.8012 2.1200 2.3801 2.5970 1.45 0.1324 0.2763

0. 4277 0.6016

.0.7869 0.9796 1.1747 1.3707 1.5640 1.7451 2.0672 2.3336

2. 5 57i7 1.50 0.1176 0.2509 10.3996 0.5630 0.7383 0.9215 1.1083 1.2975 1.4855 1.6627 1.9795 2.2445 2.70 1.55 0.1133 0.2334 0.3679 0.5184 0.6805 0.8510 1.0259 1.2043 1.3831 1.5524 1.8570 2.1212 2.3863 1.60 0.1153 0.2389 0.3681 0.5023 0.6412 0.7860 0.9372 11.1000 1.2702 1.4456 1.7892 2.1108 2.4044 1.65 0.1140 0.2376 0.3678 0.5036 0.6446 i0.7919 0.9458 1.1098 1.2857 1.4650 1.8155 2.1446 2.4459 1.70 0.1045 0.2192 0.3416 0.4703 0.6046 0.7452 0.8924 1.0495 1.2188 1.3913 1.7267 12.0399 2.3251 1.75 0.0899 0.1891 0.2960 0.4097 0.5292 0.6547 0.7862 0.9264 1.0776 1.2316

.1.5308 1.8110 2.0685 1.80 0.0818 0.1722 0.2689 0.3735 0.4857 0.6044 0.7239 0.8619 1.0058 11.1530 1.4421 1.7192 2.0095 1.25 0.0833 0.1765 0.2765 0.3835 0.4971 0.6167 0.7417 0.8756 1.0218 1.1746 1.4876 1.8072 2.1258 1.90 0.0786 0.1652 0.2595 0.3612 0.470.2 0.5858 0.7073 0.8380 0.9809 1.1299 1.4349 1.7467 2.0579 1.95 0.0719 0.1492 0.2306 0.3209 0.4188 0.5237 0.6346 0.7546 0.8857 1.0-222 1.3010 1.5858 1.8703 2.00 0.0670 0.1400 0.2175 0.2996

.03866 0.4780 0.5761 0.6825 0.7955 0.9141 1.1695 1.4396 1.7193 2.05 0.0658 0.1360 0.2099 0.2875 0.3684 0.4522 0.5390 0.6406 0.7494 0.8595 1.1003 1.3713 1.6584 2.10 0.0646 0.1341 0.2073 0.2845 0.3652 0.4491 0.5359 0.6271 0.7231

- 0.8203 1.0163 1.2362 1.4921 2.15 0.0623 0.1297 0.2012 0.2767 0.3561 0.4388 0.5247 0.6153 0.7114 0.8092 11.0060 1.2094 1.4225 2.20 0.0591 0.1233 0.1918 0.2647 03416 0.4220 0.5057 0.5946 0.6895 0.7862 10.9812 1.1826 1.3932 2.25 0.0554 0.1156 0.1802 0.2494 103229 0.4001 0.4806 0.5664 0.6587 0.7532 10.9437 1.1407 1.3465 2.30 0.0527 0.1081 0.1671 0.2319 0.3012 0.3742 0.4506 0.5323 10.6207 0.7116 10.8953 1.0355 1.2842 2.35 0.0507 0.1041 0.1594 0.2168 0.2771 0.3453 0.4169 0.4936 0.5769 0.6630 0.8376 1.0138 1.2085 2.40 0.0501 0.1030 0.1577 0.2143 0.2726 0.3327 0.3949 0.4610 0.5317 0.6086 0.7722 0.9426 1.1214 2.50 0.0474 0.0976 0.1499 0.2042 0.2603 0.3179 0.3773 0.4400 0.5076 0.5778 0.7217 0.8741 1.0370 2.60 0.0430 0.0889 0.1370 0.1873 0.2396 0.2933 0.3485 0.4065 0.4690 0.5342 0.6686 0.8107 0.9628 2.70 0.0393 0.0791 0.1206 0.1658 0.2130 0.2618 0.3119 0.3643 0.4206 0.4794 0.6014 0.7310 0.8699 2.80 0.0376 0.0757 0.1143 0.1530 0.1925 0.2333 0.2756 0.3202 0.3679 0.4196 0.5274 0.6428 0.7671 2.90 0.0357 0.0719 0.1086 0.1483 0.1892 0.2310 0.2736 0.3172 0.3617 0.4059 0.4938 0.5933 0.7024 3.00 0.0334 0.0673 0.1015 0.1360 0.1711 0.2073 0.2462 0.2884 0.3323 0.3760 0.4615 0.5566 0.6590 3.10 0.0316 0.0647 10.0990 0.1346 0.1713 0.2091 0.2478 0.2879 0.3298 0.3725 0.4591 0.5477 0.6384 3.20 0.0284 0.0581 0.0886 0.1198 0.1515 0.1856

.0.2211 0.2583 0.2976 0.3379 0.4199 0.5048 0.5928 3.30 0.0266 0.0549 0.0839 0.1139 0.1444 0.1751 0.2058 0.2367 0.2686 0.3017 0.3708 0.4445 0.5236 3.40 0.0249 0.0514 0.0789 0.1072 0.1362 0.1655 0.1948 0.2243 0.2546 0.2898 0.361 8 0.4370 0.5153 3.50 0.0233 0.0479 0.0735 0.1001 0.1274 0.1550 0.1828 0.2108 0.2395 10.2687 0.3356 0.4082 0.4847 3.60 0.0231 0.0467 0.0706 0.0949 0.1196 041447.

0.1704 0.1968 0.2238 0.2512 0.3086 0.3686 10.4329 3.70 0.0206 0.0417 0.0631 0.0859 0.1094 0.1342 0.1604

-0.1882 0.2176 0.2471 0.3053 0.3633 0.4219 3.30 0.0211 0.0427 0.0647 0.0873 0.1111 0.136-2 0.1628 0.1911 0.2213 0.2517 0.3122 0.3727 0.4339 3.90 0.0218 0.0442 0.0669 0.0902 0.1142 0.1392 0.1654 0.1935 0.2239 0.2553 0.3181 0.3817 0.4464 4.00 0.0213 0.0431 0.0653 0.0880 0.1112 0.1352 0.1600 0.1865 0.2151 0.2450 0.3065 0.3699 0.4347 4.10 0.0194 0.0392 0.0593 0.0797 0.1006 0.1220 0.1441 0.1675 0.1926 0.2189 0.2743 0.3325 0.3927 4.20 0.0174 0.0351 0.0530 0.0712 0.0897 0.1085 0.1277 0.1473 0.1676 0.1882 0.2322 0.2825 0.3349 4.30 0.0177 0.0356 0.0539 0.0724 0.0912 0.1104 0.1299 0.1498 0.1704 10.1913 0.2338 0.2779 0.3238 4.40 0.0168 10.0338 0.0510 10.0686 0.0864 0.1045 0.1229 0.1418 0.1612 0.1810 10.2211 10.2627 0.3061

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 90 of.349 Date: 08/27/03 4.50 0.0158 0.0318 0.0480 0.0644 0.0810 0.0979 0.1149 0.1324 0.1502 0.1684 0.2051 0.2428 0.2sio 4.60 0.0149 0.0300 0.0452 0.0606 0.0762 0.0921 0.1083 0.1253 0.1429 0.1607 0.1964 0.2326 0.2692 4.70 0.0151 0.0307 0.0468 0.0634 0.0805 0.0981 0.1160 0.1345 0.1537 0.1732 0.2125 0.2525 0.2932 4.80 0.0153 0.0309 0.0471 0.0639 0.0812 0.0991 0.1174 0.1364 0.1563 0.1765 0.2174 0.2596 0.3028 4.90 0.0150 0.0301 0.0453 0.0609 0.0773 0.0942 0.1117 0.1300 0.1492 0.1689 0,2090 0.2507 0.2938 5.00 0.0143 0.0285 0.0427 0.0571 0.0717 0.0867 0.1024 10.1189 0.1364 0.1544 0.1917 0.2308 0.2716 5.10 0.0132 0.0263 0.0394 0.0525 0.0657 0.0791

'0.0930 0.1075 0.1229 0.1390 0.1726 0.2083 0.2458 5.20 0.0122 0.0244 -

0.0365 0.0486 0.0608 0.0730 0.0855 0.0985 0.1 1A 2

' '0.;1268 0.1572

.1 99

' 0.2245 5.40 0.0113 0.0227 0.0342 0.0455 0.0568 0.0680 0.0790 0.0901 0.1o19 0.1143 0.1407 O.1 697 0.2008 5.60 0.0112 0.0224 0.0338 0.0453 0.0568 0.0684 0.0799 0.0912 0.1024 0.1134 0.1347 0.1553 0.1755 5.80 0.0105 0.0212 0.0319 0.0428 0.0545 0.0665 0.0786 0.0908 0.1032 0.1153 0.1388 0.1620 0.1855 6.00 0.0101 0.0205 0.0312 0.0424 0.0540 0.0660 0.0783 0.0909 0.1037 0.1164 0.1412 0.1658 0.1907 6.20 0.0099 0.0199 0.0301 0.0406 0.0512 0.0620 0.0729 0.0839 0.0949 0.1059 0.1276 0.1486 0.1691 6.40 0.0095 0.0192 0.0290 0.0391 0.0495 0.0601 0.0709 0.0819 0.0930 0.1042 0.1263 0.1482 0.1697 6.60 0.0081 0.0162 0.0243 0.0323 0.0409 0.0499 0.0591 0.0687 0.0784 0.0883 0.1078 0.1273 0.1467 6.80 0.0081 0.0163 0.0245 0.0325 0.0404 0.0481

. 0.0556 0.0629 0.0700 0.0774 0.0946 0.1120 0.1292 7.00 0.0078 0.0157 0.0236 0.0315 0.0392 0.0468 0.0543 0.0620 0.0700 0.0780 0.0942 0.1108 0.1279 7.20 0.0075 0.0150 0.0225 0.0300 0.0376 0.0452 0.0528 0.0604 0.0681 0.0761 0.0921 0.1083 0.1247 7.40.

0.0072 0.0143.0.212 0.0280 0.0351...

0.0423 0.0496.

0.0571 0.0647 0.0724 0.0879 0.1037

0. 1 197 7.60 0.0070 0.0138 0.0206 0.0272 0.0338 0.0405 0.0475

.0.0547 0.0621 0.0696 0.0843 0O:990

  • b'1 34 7.80 0.G066 0.0130 0.0194 0.0257 0.0319 0.0382 0.0446 0.0514 0.0584 0.0655 0.0796 0.0936 0.1076 8.00 0.0060 0.0120 0.0179 0.0237 0.0294 0.0352 0.0411 [ 0.0473 0.0537 0.0603 0.0735 0.0866 0.0998 8.50 0.0053 0.0105 0.0156 0.0207 1 0.0256 0.0304 0.0352 0.0400 0.0446 0.0492 0.0583 0.0676 0.0773 9.00 0.0048 0.0096 0.0144 0.0193 0.0242 0.0291 0.0341 0.0391 0.0442 0.0492 0.0594 0.0695 I 0.0799 9.50 0.0047 0.0094 0.0141 0.0189 1 0.0238 0.0287 0.0336

. 0.0386 0.0437

-0.0489 0.0593 0.j69

.0805 10.00 0.0038 0.0077 0.0116 0.0156 1 0.0197 0.0238 0.0279 0.0321 0.0365 0.0409 0.0499 I0L.0683

.."~

in. i Calc Number: GEO.HBEP.03.01 Rev Number: 0 Sheet Number: 91 of 349 Date: 08127/0-3

~~~Table 6-12c. Soil Specta for M=7.8, Set 3, Higher Vs Soil Profile PerI (Sec)

O.l I.2-i0.

0.4g 0.5e 0.6 0.7g J 0. 8.

0.9st LOSi 1.211 1.i 0.01 0.1811 0.3022 0.4167 0.5548 0.6600 0.7582 0.8529 0.9380 1.0068 1.0595 1.1406 1.2313 1.347 0.03 0.1850 0.3074 0.4211 0.5608 0.6664 0.7644 0.8591 0.9442 1.0128 1.0653 1.1455 1.2349j13496J 0.04 0.1899 0.3270 0.4267 0.5670 0.6725 0.7704 0.8650 0.9500 1.0187 1.0708 1.1500 1.2383 1.3521aL 0.05 0.2150-0.3546 0O.4275 ~'0:5707

-0.6790 0:7771" 0.8720 0:9577.-1.0255 1.0782 -

1.1559 -1.2428 1-135501I 0.06 0.2725 0.3789 0.4503 0.5903 0.6958 0.7919 0.8856 0.9706 1.0379 1.0898 1.1653 1.2495 1.3597 0.07 0.3079 0.4588 0.4996 0.6028 0.7095 0.8056 0.9003 0.9855 1.0529 1.1033 1:1760 1.2571 1.3651 0.08 0.3165 0.5474 0.6062 0.6041 0.6873 0.7886 0.8890 0.9798 1.0530 1.1067 1.1813 1.2603 1.3649 0.09 0.3548 0.5523 0.6369 0.6690 0.7743 0.8708 0.9628 1.0450 1.1077 1.1537 1.2145 1.2863 1.3856 0.10 0.3531 0.5498 0.6850 0.8324 0.9510 1.0336 1.1028 1.1663 1.2111 1.2412 11.2710 1.3210 1.3987 0.11 0.3997 0.6014 0.7621 0.8498 0.8872 0.9641 1.0429 1.1209 1.1779 1.2213 1.2813 1.3384 11.4098 0.12 0.4122 0.7071 0.8562 0.9432 1.0090 1.0787 1.1442 1.2107 1.2661 1.3041 1.3392 1.3633 1.4050 0.13 0.4564 0.7244 0.8925 1.0240 1.0569 1.0971 1.1206 1.1208 1.1714 1.2147 1.2573 1.3410 1.4644 0.14 0.4311I 0.8070 0.9487 1.0222 1.0864 1.1249 1.1244 1.1488 1.1548 1.1726 1.1873 1.2939 1.4305 0.15 0.4073 0.7751 1.0113 1.1545 1-.2086 1.2348 1.2335 1.2984 1.3369 1.3539 1.3319 1.3536 1.4172 0.16 0.4345 0.7449 0.9978 1.1424 1.2545 1.3674 1.4653 1.5292 1.5680 1.5928 11.5613 1.4824 1.5208 0.17 0.5347

-~0.7906 0:.9932--f--r1604 1.2849

-1.4310 1.5072 1.540V' 7:5 80-5 1.6131

-1.59,79-1.5966 1.20 0.18 0.6356 0.9335 1.0863 1.1860 1.3376 1.4710 1.5611 1.5932 1.6030 1.6213 1.6879 1.8070 1.9368 0.19 0.5855 0.9481 1.1683 1.3126 1.4264 1.5005 1.5598 1.6140 1.6401 1.6661 1.7320 1.7977 1.9313 0.20 0.6116 1.0798 1.3256 1.4542 1.4950 1.5787 1.6197 1.6393 1.6887 1.7359 1.7993 1.~8 628 1.9175 0.21 0.5270 0.9420 1.3471 1.6358 1.7069 1.6799 1.7083 1.7203 1.7647 1.8168 1.8878 1.9500 1.9984 0.22 0.5699 0.9678 1.3770 1.7345 1.8993 11.9241 1.8729 1.8660 1.9125 1.9514 1.9605 1.9668 2.0142 0.23 0.5680 0.9815 1.3619 1.7581 1.9792

!2.0390 1.9989 2.0009 2.0050 1.9927 12.0466 12.0714 12:1587 0.24 0.5420 1.0920 1.4838 1.7393 2.0181 2.2152 2.3252 2.3547 2.3673 2.3524 2.2916 2.3071 2.3732 0.25 0.5096 1.0413 1.4402 1.8314 2.1551 2.3865 2.5254 2.5853 2.6178 2.6023 2.5016 2.4573 12.4702 0.26 0.4295 0.9062

.1.4359 1.8999 2.2547 2.5082 2.6662 12.7531 2.7990 2.7820 2.6432 2.5392 2.4897 0.27 0.3997 0.8146 1.3429 1.7931 2.1290 2.3709 2.5294 2.6225 2.6775 2.6695 2.5619 2;4967 2.3815 0.28 0.3760 0.7019 1.0944 1.5422 2.0231 12.4396 2.7184 2.8567

-2.9678 3.0402 3.0342 2.9559 2.8163 0.29 0.3456 0.6883 1.0554 1.4953 1.9548 2.3639 2.6554 2.8204 2.9454 3.0321 3..0492 3.0023 2.8988 0.30 0.3370 0.6451 10.9757 1.3727 1.7996 2.1970 2.5012 2.6836 2.8180 2.9100 2.9453 2.9254 2.8550 0.31 0.3609 0.772 0.9280 1.1957 1.5796 1.9483 2.2342 2.4785 2.6945

.2.8607 3.0051 3.0070 2.8852 0.32 0.3679 0.6768 0.9507 1.2169 1.4645 1.7018 1.9897 2.2376 2.4833 2.6975 2.9048 2.9346 2.9165 0.33 0.3529 0.6367 0.9026 1.1759 1.4269 1.6593 1.8833 2.1214 2.3563 2.5610 2.7578 2.8163 2.7942 0.34 0.392-1 0.6690 0.9459 1.18-76 1.412-7 1.6514 1.8587 2.0198 2.2110 2.4128 2.7793 2.9468 3.0441 0.35 0.4141 0.7058 0.9514 1.1588 1.3828 11.6429 1.8735 2.0588 2.2760-2.5074 2.8920 3.0733 3.0567 0.36 0.4245 0.7141 0.9711 1.1647 1.2975 11.4345 1.6613 1.8454 2.0563 2.2791 2.6256 2.9657 3.1190 0.37 0.4614 0.7818 0.9671 1.1194 1.2707 1.4088 1.5419 1.6669 1.8727 2.1273 2.6141 3.0406 3.3494 0.38 0.4850 0.8091 1.0103 1.1431 1.2708 1.4340 1.6716 1.8432 2.0096 2.1800 2.6284 3.056-7 3.3851 0.39 0.4955 0.8282 1.0194 1.1201 1.2245 1.3683 1.5691 1.7741 1.9703 2.1711 2.5976 3.0376 3.3363 0.40 0.4719 0.8593 1.0889 1.2367 1.3351 1.4174 1.5163 1.5964 1.7684 1.9735 2.3773 2.8102 3.2024 0.41 0.4525 0.8586 1.1518 1.2953 1.3610 1.4502 1.5007 1.5623 1.7158 1.9010 2.3025 2.7415 3.1435 0.42 0.4522 0.8985 1.2287 1.3968 1.4750 1.5461 1.5982 1.6238 1.7191 1.9106 2.3339 2.7366 3.2053 0.43 0.4377 0.8996 1.2580 11.4493 1.5434 11.6227 1.6765 1.6986 1.7832 1.9379 2.3591 2.7800 3.2314 0.44 0.3850 0.8217 1.1749 1.3718 1.4749 1.5630 1.6253 1.6569 1.7342 1.8476 2.2255 2.6354 3.0243 0.45 0.3308 0.6993 1.0051 1.2894 1.4679 1.5898 1.6633 1.6925 1.7675 1.8728 2.0721 2.3216 2.6455 0.46 0.3195 0.6580 1.0109 1.2821 1.4869 1.6285 1.7217 1.7562 1.8451 1.9640 2.1947 2.4550 2.7839 0.47 0.3224 0.6634 1.0136 1.3257 1.5401 1.6530 1.7136 1.7549 1.8478 1.9723 2.2143 2.4745 2.7999 0.48 0.3136 0.6542 1.0078 1.3230 1.5383 1.7041 1.8004 1.7900 1.8271 1.9359 2.1775 2.4281 2.7367 0.49 0.2897 0.6135 0.9530 1.2642 1.5538 1.7654 1.8671 1.8574 1.8969 1.9783 2.2060 2.4550 2.7586 0.50 0.2780 0.5881 0.9224 1.2580 1.5470 1.7845 1.9309 1.9755 2.0479 2.1406 2.2860 2.4970 2.8036 0.51 0.2661 0.5730 0.9064 1.2159 1.5472 1.8095 1.9646 2.0179 2.1009 2.2059 2.3812 2.5165 2.7262 0.52 0.2455 0.5244 0.8332 1.1375 1.4565 1.7092 1.8629 1.9232 12.0132 12.1'250 2.3189 2.4700 2.6148 0.53 0.2381 0.4880

.0.76659 1.0573 1.3235 1.5408 1.6850 1.8341 1.9699 2.1082 2.3512 2.5405 2.7250 0.54 0.2389 0.4885 0.7574 1.0149 1.2780 1.5594 1.8162 1.9807

.2.1193 2.2551 2.4902 2.7021 2.9272 0.35 0.2436 0.5013 0.7821 1.0553 1.3277 1.6076 1.8562 2.0128 2.1493 2.3035 2.5852 2.7978 2.9800 0.56 0.2442 0.4889 0.7664 1.0393 1.3069 1.5737 1.8067 12.0490 2.2485 2.4265 2.7231I 2.9569 3.1528 0.57 0.2509 0.5041 0.7446 0.9885 1.2428 1.5264 1.8309 2.0723 2.2698 2.4482 2.7492 2.9921 3.2038 0.58 0.2503 0.5080 0.7581 0.9893 1.2390 1.5115 1.8028 2.0344 2.2269 2.4023 2.7002 2.9457 3.1634 0.60 0.2382 0.4902 0.7442 0.9762 1.2137 1.4660 1.7137 1.9107 2.0802

[2.2316 2.5155 2.7/?53 2-.9700 0.62 0.2430 0.4565 0.7040 0.9330 1.1599 11.3959 1.6295 1.8233 1.9918 2.1380 2.3814 2.5986 2.7778 0.64 0.2474 10.4618 0.6669 0.8677 1.0840 11.3053 1.5256 1.7144 F1.8948 I~2.0742 2.4744 2.8020 3.0520 0.66 0.2461 10.4632 I-0.6559 0.8164 0.9956

- 1.1864 1.3879 1.5804 I1.7895 I2.0088 2.4323 2.7691 3.0512

Galc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 92 of 3 49

~~ ~~~~Date:

08/27/0 3

)

US6 0.2404 0.4506 0.6420 J0.7942 30.9376 1.0967 1.3055 1.5079

-1.6950 1.72 226 256 2.8252 0.70 0.2215 0.4312 0.6463 0.8441 1.0254 1.1935 1.3520 1.5096 1.6834 1.8609 -~2.2201 I 2.5699 2.9139 0.72 0.2262 0.4424 0.6663 0.8798 1.0838 1.2779 1.4620 1.6407 1.8313 2.0225 I2.4060 2.7750 3.13 10 0.74 0.2169 0.4204 0.6326 0.406 1.0453 1.2432 1.4316 1.6118 1.7997 1.9853.i2.3543 2.7076 3.0466 0.76 0.2338 0.4292 0.6005 0.7971 0.9971 1.1937 1.3832 1.5639 1.7491 1.9302 2.2880 2.6316

-2.9616 0.78 0.2500 0.4581 0.6395 0.7798 0.9-226 1.1123 1.2974 1.4753 1.65411 1.8289 2.1708 2.5004 2.8160 o ;O.

0.2585,

.0.4737..-..

0.6601 0.8049

.0.9333 1.0570

.1.1894.. 1.3610 1.3+/-

.1..6979 2.0209 2.3331 12.6322 0.82 0.2593 0.4763 0.6713 0.8381 0.9826 1.1128 1.2310 1.3407 1.4576

-1.5998 1.9257 2.2 536 2.5920 0.84 0.2563 0.4805 0.6911 0.8665 1.018 1.1549 1.2764 1.3865 1.5040 1.6160 1.8593 12.1843 2.5233 0.86 0.2496 0.4835 0.6997 0.8812 1.0393 1.1810 1.3054 1.4159 1.5334 1.6450 1.8506 2.0737 2.4063 0.88 0.2407 0.4719 0.6875 0.8707 1.0307 1.1743 1.2992 1.4080 1.5226 1.6313 1.8297 2.0114 2.2255 0.90 0.2271 0.4484 0.6580 0.8383 0.9962 1.1375 1.2593 1.3631 1.4719 1.5741 1.7591 1.9250 2.0942 0.92 0.2321 0.4482 0.6374 0.8064 0.9607 1.0981 1.2156 1.3135 1.4151 1.5104 1.6797 1.8294 1.9794 0.94 0.2460 0.4750 0.6783 0.8423 0.9886 1.1300 1.2605 1.3737 11.4894 1.5996 1.7940 1.9619 2.1238 0.96 0.2540 0.4905 0.7034 0.8168 1.0317 1.1816 1.3223 1.4471 1.5747 1.6962 1.9132 2.1021 2.2837 0.98 0.2588 0.4999 0.7181 0.8971 1.0571 1.2120 1.3588 1.4925 1.6282 1.7576 1.9910 2.1955 2.3909 1.00 0.2629 0.5064 0.7249 0.9044 1.0652 1.2209 1.3703 1.5090 1.6498 1.78317 2.0-268 2.2410 2.4449 1.05 0.2516 0.4833 0.7048 0.8976 1.0653 1.2200 1.3587 1.4754 1.5875 1.6975 1.9075 2.0887 2.2876

-A~0 0.2338 0.4659 0.6890 0.8811.

1.04.7..

1.2100 1.377-4.

1.5272 1.6.716. ;.1.8044 2.0336 2.2175

.2.3680 1.15 0.2151 0.4289 0.6534 0.8644 1.0578 1.2371 1.4004 1.5463 1.6902 1.8269 12.0148 2.2907 2.4830 1.20 0.1945 0.3958 0.5968 0.7871 0.9653 1.1333 4.2888 1.4299 1.5677 1.6959 1.9228 2.1653 2.4149 1.25

0. 1740 0.3555 0.5388 0.7379 0.9418 1.1356 1.3048 1.4404 1.5573 1.6587 1.8403 2.0956 2.3439 1.30 0.1602 0.3461 0.5538 0.7771 0.9975 1.2014 1.3795 1.5229 1.6474 1.7552 1.9258 2.0525 2.2918 1.35 0.1505 03239 0.5168 0.7272 0.9454 1.1611 1.3659 1.5475 1.7045 1.8394 2.0494 2.1941 12.2977 1.40 0.1387 0.2977 0.4760 0.6693 0.8682 1.0639 1.2498 1.4339 1.6044 1.7534 1.9927 2.1609 12.2789 1.45 0.1290 0.2706 0.4311 10.6090 0.8064 1.01.04 1.2173 1.4183 1.5976 1.7550 2.0083 2.2086 2.4281 1.50 0.1222 0.2580 10.4048 0.5601 0.7197 0.8963 1.0815 1.2597 1.4168 1.5534 1.-7804 2.0138 2.2227 1.55 0.1174 0.2441 0.3784 0.5164 0.6565 0.7984 0.9431 1.0901 1.2338 1.3727 11.6399 1.8912 2.1289 1.60 0.1118 0.2328 0.3617 0.4949 0.6303 0.1671 0.9063 1.0472 1.1841 1.3191 11.6181 1.8986 2.1512 1.65 0.1039 0.2162 0.3362 0.4614 0.5976 0.7370 0.8812 1.0366 1.2039 1.3657 1.6818 1.9790 2.2470 1.70 0.0974 0.2024 0.3147 0.4351 0.5671 0.7029 0.8440 1.001 1.1647 1.3231 1.6344 1.9304 12.2 012 1.75 0.0942 0.1951 0.3043 0.4115 0.5409 0.6752 0.8166 0.9661 1.1201 1.2756 1.5840 1.8817 12.1586 1.80 0.0932 0.1938 0.3018 0.4153 0.5315 0.6504 0.7945 10.9479 1.0977 1.2448 1.5395 1.8305 12.1091 1.85 0.0920 0.1917 0.2990 0.4130 0.5307 0.6510 0.7751 0.9038 1.0310 1.1557 1.4332 1.7089 11.9717 1.90 0.0888 0.1854 0.2899 0.4021 0.5190 10.6390.

0.7634 0.8934 1.0217 1.1480 1.4022 1.6585 11.9154 1.95 0.0836 0.1748 0.2736 0.3808 0.4937 0.6101 0.7315 0.8586 0.9842 1.1079 11.3575 1.6092 1.8610 2.00 0.0769 0.1614 0.2529 0.3530 0.4592 0.5694 0.6845 0.8053 0.9246 1.0421 11.2795 1.5192 1.7591 2.05 0.0691 0.1469 0.2308 0.3221 0.4206 0.5225 0.6292 0.7414 0.8530 0.9659 1.1960 1.4309 1.6715 2.10 0.0658 0.1363 0.21 18 0.2932 0.3807 0.4737 0.5714 0.6744 10.7778 0.8833 1.1039 1.3377 1.5829 2.15 0.0579 0.1198 0.1860 0.2615 0.3423 0.4268 0.5159 0.6101 10.7034 0.7965 0.9984 11.2123 1.4360 2.20 0.0554 0.1141 0.1769 0.2439 0.3139 0.3859 0.4646 0.515 0.6389 0.7280 0.9146 1.1106 1.3128 2.25 0.0532 0.1092 0.1686 0.2324 0.2993 10.3683 0.4394 0.5128 0.5899 10.6754 0.8538 1.0419 1.2371 2.30 0.0523 0.1072 0.1647 0.2246 0.28-70 0.3514 0.4196 0.4899 0.5597 0.6295 0.7979 0.9784 1.1668 2.35 0.0506 0.1039 0.1602 0.2192 0.2811 0.3451 0.4112 0.4788 0.5456 0.6120 0.7497 0.9169 1.0991 2.40 0.0474 0.0975 0.1509 0.2073 0.2667 0.3286 0.3929 0.4592 0.5246 0.5895 0.1234 0.8681 11.0333 2.50 0.0404 0.0832 0.1282 0.1762 0.2268 0.2791 0.3334 0.3927 0.4519 0.5105 0.6307 0.7584 10.9055 2.60 0.0425 0.0874 10.1349 0.1849 0.2367 0.2901 0.3461 10.4055 0.4655 0.5263 0.6549 0.7938 0.9429 2.70 0.0386 0.0770 0.1157 0O.1567 0.2028 0.2505 0.3005 0.3543 0.4092 0.4651 0.5837 0.7134 0.8549 2.80 0.0351 0.0712 0.1083 0.1471 0.1875 0.2289 0.2724 0.3 198 0.3675 0.4157 0.5170 0.6322 0.7566 2.90 0.0336 0.0680 0.1038 0.1412 0.1803 0.2206 0.2619 0.3040 0.3455 0.3866 0.4694 0.5556 0.6502 3.00 0.0333 0.0667 0.1007 0.1368 0.1746 0.2137 0.2541 0.2957 0.3366 0.3169 0.4581 0.5412 10.6302 3.10 0.0322 0.0647 0.0976 0.1320 0.1683 0.2059 0.2450 0.2854 10.3253 10.3646 0.4435 0.5238 10.6074 3.20 0.0301 0.0608 0.0918 0.1241 0.1582 0.1937 0.2307 0.2692 0.3071 10.3446 0.4199 0.4963 10.5752 3.30 0.0275 0.0559 0.0858 0.1171 0.1494 0.1820 0.2150 0.2481 0.2827 10.3176 0.3877 0.4588 10.5321 3.40 10.0277 0.0566 0.0870 0.1190 0.1522 0.1860 0.2203 0.2550 0.2894 10.3238 0.3943 0.4681 0.5466 3.50 0.0263 0.0539 0.0830 0.1139 0.1464 0.1797 0.2139 0.2488 0.2834 0.3180 0.3888 10.4628 0.5413 3.60 0.0233 0.0465 0.0697 0.0961 0.1242 0.1534 10.1836 0.2149 0.2458 0.2767 0.3400 10.4064 0.4768 3.70 0.0210 0.0422 0.0632 0.0842 0.1054

0. 1275 0.1515 10.1778 0.2046 0.2317 0.2883 10.3486 0.4128 3.80 0.0195 0.0393 0.0591 0.0787 0.0983 0.1186 0.1404
0. 1643 0.1890 0.2140 0.2665 0.3224 0.3821 3.90 0.0191 0.0387 0.0586 0.0788 0.0988 0.1185 0.1380 0.1608 0.1845 0.2088 0.2598 0.3144 10.3728 4.00 0.0192 0.0389 0.0591 0.0797 0.1004 0.1210 0.1417 0.1625 0.1833 0.2043 0.2471 0.2953 0.3508 4.10 0.0174 0.0358 0.0549 0.0748 0.0950 0.1 153 0.1356 0.1561 0.1767 0.1973 0.2395 0.2833 0.3283 4.20 0.0176 0.0347 0.0513 0.0680 0.0845 0.1005 0.1173 0.1354 0.1534 0.1714 0.2085 0.2470 0.2869 4.30 0.0175 0.0351I 0.0532 0.0-712 0.0890 0.1064 0.1231 0.1389 0.1542 0.1693 0.1983 0.2326 0.2733 4.0 0.0175 0.0355 0.0539 072 0.10

.092

[.20 0149 010 0.1766 0.2080 0.2388 0.2697

Calc Number: GEO.BIP.03.02 Rev Number: 0 Sheet Number: 93 of 349 Date: 08/27/03 4.50 0.0172 0.0349 0.0532 0.0717 0 0904 [ 0.1089 0.1270 0.1445 0.1616 0.1784 0.2112 0.2433 0.2756 4.60 0.0165 0.0335 0.0510 0.0690 0.0872 0.1054 0.1234 0.1409 0.1580 0.1748 0.2078 0.2448 0.2837 4.70 0.0153 0.0312 0.0477 0.0647 0.0820 0.0993 0.1166 0.1336 0.1502 0.1666 0.2013 0.2385 0.2770 4.80 0.0139 0.0284 0.0435 0.0593 0.0756 0.0923 0.1095 0.1271 0.1444 0.1616 0.1961 0.2309 0.2660 4.90 0.0132 0.0273 0.0419 0.0572 0.0730 0.0892 0.1060 0.1231 0.1401 0.1569 0.1907 0.2249 0.2594 5.00 0.0126 0.0259 0.0399 0.0545 0.0697 0.0853 0.1014 0.1180 0.1344 0.1506 0.1834 0.2166 0.2503 5.10 0.0117 0.0243 0.0375 0.0514 0.0658 0 0S06 0.0960 0.1119 0.1276 0.1431 0.1745 0.2065 0.2390 5.20 0.0118 0.0241 0.0372 0.0510 0.0651 o.J79 40.0939 0.1086 0.1232 0.1379 0.1678 0.1989 0.2311 5.40 0.0112 0.0226 0.0347 0.0476 0.0612 0.0752 0.0895 0.1041 0.1185 0.1330 0.1628 0.1939 0.2265 5.60 0.0096 0.0195 0.0299 0,0409 0.0521 0.0635 0.0750 0.0864 0.0975 0.1083 0.1297 0.1506 0.1746 5.80 0.0091 0.0183 0.0275 0.0371 0.0471 0.0575 0.0682 0.0793 0.0904 0.1014 0.1234 0.1453 0.1674 6.00 0.0088 0.0175 0.0261 0.0348 0.0440 0.0537 0.0637 0.0742 0.0848 0.0954

_ 0.1167 0.1383 0.1601 6.20 0.0086 0.0173 0.0259 0.0344 0.0428 0.0512 0.0596 0.0696 0.0796 0.0896 0.1101 0.1309 1 0.1521 6.40 0.0085 0.0170 0.0256 0.0341 0.0425 0.0509 0.0592 0.0677 0.0764 0.0854 0.1042 0.1240 0.1447 6.60 0.0084 0.0170 0.0257 0.0344 0.0433 0.0521 0.0609 0.0698 0.0786 0.0873 0.1048 0.1223 0.1396 6.80 0.0077 0.0156 0.0237 0.0320 0.0404 1 0.0488 0.0574 0.0660 0.0746 0.0832 0.1003 0.1176 0.1349 7.00 0.0069 0.0139.0.0213 0.0291 0.0370 0.0451 0.0532 0.0614 0.0695 0.0777 0.0943 0.1114 0.1290

-7.20 0.0071 0.0144 0.0217 0.0292 0.0368 0.0443 0.0517 0.0590 0.0665 0.0745 0.0909 0.1079 0.1256 7.40 0.0069S 7;;.0.0138 0.0210, 0.0284 0.0358 l 0.0433 0.0508 0.0582 0.0655 0.0727 0.08_.7, 0.1002 0.1132 7.60 0.0061 0.0125 0.0190 0.0258 0.0327 0.0396 0.0467 0.0538 0.0608 0.0677 0.0813 0.0946 0.1077 7.80 0.0054 0.0109 0.0163 0.0218 -

0.0278 0.0339 0.0402 0.0466 0.0528 0.0591 0.0716 0.0843 0.0969 8.00 0.0051 0.0101 0.0152 0.0203 0.0253 0.0304 0.0356 0.0409 J 0.0461 0.0513 0.0618 0.0724 0.0828 8.50 0.0050 0.0101 0.0152 0.0205 0.0257 10.0310 0.0363 0.0416 0.0469 0.0521 0.0626 0.0731 0.0835 9.00 0.0045 0.0090 0.0135 0.0180 0.0228 0.0277 0.0325 0.0374 l 0.0423 0.0472 0.0570 0.0669 0.0768 9.50 0.0040 0.0081 0.0121 0.0162 0.0204 0.0247 0.0292 0.0337 0.0382 0.0427 0.0517 0.0607 0.0696 10.00 0.0039 0.0079 0.0118 0.0156 0.0193 0.0230 0.0266 0.0302 0.0339 0.0379 0.0460 0.0544 0.0630

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 94 of 349 Date: 08/27/03

7. METHOD AND EQUATION

SUMMARY

7.1 Methods The-amplificatien factors-are--developed using the following steps:.

1. Compute Rock Spectral Values Using the program SPCTRL, compute the response spectral values of the rock spectra at the same spectral periods as the soil spectral values. Average the three sets of rock response spectral values (from the three time histories) for each magnitude and each input PGA value.
2. Compute Site Amplification Factors

.._-.. Fax Compute amplification factors as the ratio of response spectra of the surface ground motion to the response spectra of the input rock time histories for each PGA level.

Average the amplification factors for the three time histories for each input rock PGA level and for each profile.

3. Select a Subset of Spectral Periods Select a subset of the 152 spectral periods used in steps 1, 2, and 3 that adequately capture the peaks in the site amplification factors from step 3. This step reduces the volume of the hazard runs that will be needed.

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 95 of 349 Date: 08/27/03 7.2 Equations 7.2.1 Amplification factors are computed as the ratio of surface response spectral acceleration to input motion spectral acceleration.

I :

AinpFac S.=

S.-.oc (7-1) where S. is pseudo-absolute acceleration (spectral acceleration).

Calc Number: GEO.HREP.03.02 Rev Number: 0 Sheet Number: 96 of 349 Date: 08/27/03

8. SOFTWARE Two computer programs were used to develop the amplification functions: SHAKE96 and SPCTLR 8.1 Prozram SPCTLR The response spectrum calculation program SPCTLR.EXE is used to compute the response spectra of time histories. SPCTLR.EXE was verified in calculation GEO.DCPP.01.32 in accordance with Section 4.2.1 of GEO.001 Rev. 6.

8.2 Program SHAKE 96 i

The program SHAKE96 was used to compute the soil response spectra for the additional input time histories. This program was verified in.GEO.HBIP.02.06.

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 97 of 349 Date: 08/27/03

9. BODY OF CALCULATIONS 9.1 Compute Rock Spectra The response spectra of the input rock time histories (listed in Appendix A) are computed for each of the, nine input time histories using the computer program,SPCTLR, The results are listed in Tables 9-1 to 9-3. The normalized spectral shapes are computed by dividing the spectral acceleration by peak acceleration. Note: T=0.01 sec is assumed to be equal to the peak acceleration (see assumption 3.1).

The average spectral shape for the three sets of time histories is given in the last column of each table. For the very short spectral periods (e.g. 0.03-0.04 sec), in some cases the computed spectral acceleration is slightly smaller than the peak acceleration. This is an artifact of the interpolation methods used in SPCTLR. It is not a significant effect.

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 98 of 349 Date: 08/27/03 Table 9.1 Response spectra or input rock motions for M=6.0 Response Spectra of Nounalized Spectral Shape of bput Input Rock Motions (a)

Rock Motions Per Average (sec)

Set I Set2 Set 3 Set I _I Set2.

Set 3 0.01 0.1706 0.1669 0.1746 1.0000 1.0000 1.0000 1.0000 0.03 0.1566 0.1624 0.1585 0.9183 0.9730 0.9078 0.9330 0.04 0.1796 0.1832 0.1775 1.0529 1.0972 1.0167 1.0556 0.05 0.1994 0.1979 0.1962 1.1689 1.1853 1.1232 1.1591 0.06 0.2196 0.2257 0.2243 1.2874 1.3519 1.2842 1.3078 0.07 0.2364 0.2430 0.2501 1.3858 1.4558 1.4322 1.4246 0.08 0.2554 0.2572 0.2588 1.4972 1.5405 1.4820 1.5066 0.09 0.2848 0.2834 0.2838 1.6695 1.6978 1.6253 1.6642 0.10 0.3118 0.2945 0.3009 1.8279 1.7642 1.7228 1.7716 0.11.

0.3189 0.3177.

0.3185 1.86981 1.9030 1.8237 1.8655 0.12 0.3365 0.3308 0.3310 1.9730 1.9814 1.8954 1.9499 0.13 0.3504 0.3345 0.3473 2.0545 2.0038 1.9887 2.0157 0.14 0.3463 0.3493 0.3454 2.0305 2.0924 1.9779 2.0336 0.15 0.3556 0.3543 0.3541 2.0846 2.1227 2.0275 2.0783 0.16 0.3579 0.3518 0.3686 2.0985 2.1076 2.1105 2.1055 0.17 0.3670 0.3588 0.3413 2.1514 2.1493 1.9543 2.0850 0.18 0.3689 0.3657 0.3630 2.1627 2.1905 2.0784 2.1439 0.19 0.3526 0.3467 0.3521 2.0672 2.0769 2.0165 2.0535 0.20 0.3667 0.3659 0.3466 2.1501 2.1917 1.9850 2.1089 0.21 0.3438 0.3365 0.3400 2.0157 2.0159 1.9470 1.9929 0.22 0.3333 0.3352 0.3382 1.9541 2.0080 1.9367 1.9663 0.23 0.3219 0.3300 0.3281 1.8874 1.9-767 1.8788 1.9143 0.24 0.3332 0.3309 0.3225 1.9535 1.9821 1.8465 1.9274 0.25 0.3322 0.3377 0.3185 1.9474 2.0232 1.8237 1.9314 0.26 0.3177 0.3088 0.3129 1.8628 1.8498 1.7917 1.8348 0.27 0.3029 0.3095 0.3130 1.7759 1.8541 1.7926 1.8075 0.28 0.2966 0.3189 0.3014 1.7391 1.9104 1.7259 1.7918 0.29 0.2979 0.3076 0.2989 1.7463 1.8426 1.7118 1.7669 0.30 0.3029 0.2965 0.2921 1.7756 1.7760 1.6727 1.7414 0.31

  • 0.3002 0.2995 0.2750 1.7601 1.7940 1.5746 1.7096 0.32 0.2868 0.2915 0.2767 1.6814 1.7461 1.5843 1.6706 0.33 0.2594 0.2826 0.2726 1.5207 1.6932 1.5611 1.5917 0.34 0.2719 0.2774 0.2659 1.5939 1.6619 1.5224 1.5927

.0.35 0.2695 0.2736 0.2641 1.5798 1.6389 1.5123 1.5770 0.36 0.2590 02668 02480 1.5183 1.5982 1.4203 1.5123 0.37 0.2573 02546 0.2573 1.5087 1.5251 1.4734 1.5024 0.38 02574 0.2517 0.2478 1.5092 1.5076 1.4191 1.4786 0.39 0.2548 02433 0.2453 1.4940 1.4576 1.4047 1.4521 OAO 0.2491 0.2412 0.2422 1.4602 1.4449.

13866 1.4306 OA.1 02413 0.2417 02347 1.4149 11.4480 1.3439 1.4023 0.42 02323 0.2299 0.2231 1.3619 1.3772 1.2775 1.3389 0.43 0.2232 0.2192 0.2233 1.3084 1.3129 1.2785 12999 0.44 0.2130 0.2156 0.2020 1.2488 1.2913 1.1566 1.2322 0.45 0.2105 0.2081 02083 1.2339 1.2468 1.1928 1,2245 0.46 0.2069 0.2071 0.2069 1.2132 1.2409 1.1846 12129 0.47 0.2041 02055 0.1980 1.1965 1.2311 1.1336 1.1871 0.48 02005 0.2009 0.1899 1.1753 1.2033 1.0873 1.1553 0.49 0.1971 0.1946 0.1874 1.1558 1.1655 1.0734 1.1316 0.50 0.1929 i 0.1880 0.1853 1.1310 1.1261 1.0613 1.1061

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 99 of 349 Date: 08/27/03 0.51 0.1883 0.1822 0.1802 1.1040 1.0917 1.0317 1.0758 0.52 0.1837 0.1778 0.1858 1.0767 1.0649 1.0640 1.0685 0.53 0.1789 0.1744 0.1804 1.0491 1.0449 1.0333 1.0424 0.54 0.1738 0.1717 0.1719 1.0189 1.0286 0.9844 1.0106 0.55 0.1715 0.1692 0.1657 1.0055 1.0133 0.9490 0.9893 0.56 01693 0.1664 0.1622 0.9923 0.9970 0.9290 0.9728 0.57 0.1639 0.1634 0.1618 0.9609 0.9790 0.9266 0.9555 0.58 0.1599 0.1603 0.1618 0.9374 0.9600 0.9263 0.9412 0.60 0.1544 0.1543 0.1521 0.9054 0.9245 0.8709 0.9003 0.62 0.1462 0.1496 0.1494 0.8570 0.8962 0.8552 0.8695 0.64 0.1366 0.1459 0.1463 0.8011 0.8738 0.8380 0.8376 0.66 0.1345 0.1421 0.1351 0.7887 0.8510 0.7736 0.8044 0.68 0.1402 0.1372 0.1304 0.8217 0.8220 0.7465 0.7967 0.70 0.1398 0.1316 0.1258 0.8197 0.7886 0.7203 0.7762 0.72 0.1230 0.1264 0.1268 0.7211 0.7569 0.7261 0.7347 0.74 0.1223 0.1256 0.1213 0.7169 0.7526 0.6944, 0.7213 0.76 -0.1188 0.1239 0-.1085 0.6967 0.7422 0.6212 0.6867 0.78 0.1130 0.1202 0.1177 0.6625 0.7199 0.6738 0.6854 0.80 0.1119 0.1158 0.1197 0.6559 0.6939 0.6852 0.6783 0.82 0.1093 0.1119 0.1158 0.6406 0.6705 0.6631 0.6581 0.84 0.1061 0.1107 0.1090 0.6220 0.6630 0.6241 0.6364 0.86 0.1029 0.1073 0.1045 0.6035 0.6426 0.5982 0.6148 0.88 0.1002 0.1025 0.1007 0.5871 0.6140 0.5765 0.5925 0.90 0.0978 0.0974 0.0981 0.5731 0.5835 0.5616 0.572 0.92 0.0957 0.0967 0.0962 0.5608 0.5792 0.5511 0.5637

--0.94 0.0936 0.0980 0.0957 0.5490 0.5868 0.5482 0.5613 0.96 0.0916 0.0976 0.0945 0.5368 0.5849 0.5413 0.5543 0.98 0.0894 0.0958 0.0929 0.5241 0.5740 0.5319 0.5433 1.00 0.0871 0.0929 0.0908 0.5108 0.5563 0.5197 0.5289 1.05 0.0811 0.0838 0.0835 0.4757 0.5017 0.4779 0.4851 1.10 0.0751 0.0765 0.0762 0.4403 0.4582 0.4361 0.4449 1.15 0.0720 0.0717 0.0721 0.4223 0.4297 0.4128 0.4216 1.20 0.0688 0.0669 0.0696 0.4034 0.4006 0.3987 0.4009 1.25 0.0649 0.0651 0.0656 0.3803 0.3898 0.3755 0.3819 1.30 0.0606 0.0657 0.0606 0.3550 0.3933 0.3472 0.3652 1.35 0.0570 0.0612 0.0580 0.3343 0.3665 0.3322 0.3443 1.40 0.0547 0.0542 0.0549 0.3208 0.3245 0.3145 0.3199 1.45 0.0523 0.0514 0.0521 0.3066 0.3082 0.2983 0.3044 1.50 0.0501 0.0486 0.0498 0.2937 0.2912 0.2851 0.2900 1.55 0.0483 0.0470 0.0478 02829 0.2814 0.2735 0.2793 1.60 0.0460 0.0467 0.0458 0.2695 0.2795 0.2623 0.2704 1.65 0.0434 0.0456 0.0438 0.2544 0.2731 0.2508 0.2594 1.70 0.0409 0.0434 0.0419 0.2396 0.2600 0.2397 0.2464 1.75 0.0397 0.0395 0.0400 0.2329 0.2367 0.2293 0.2330 1.80 0.0383 0.0372 0.0384 0.2247 0.2228 0.2200 0.2225 1.85 0.0367 0.0364 0.0369 0.2152 0.2180-' 0.2115 0.2149 1.90 0.0350 0.0346 0.0356 0.2050 0.2075 0.2036 0.2054 1.95 0.0331 0.0341 0.0342 0.1942 02042 0.1960 0.1981 2.00 0.0313 0.0331 0.0329 0.1833 0.1985 0.1885 0.1901 2.05 0.0306 0.0319 0.0316 0.1794 0.1912 0.1811 0.1839 2.10 0.0302 0.0305 0.0304 0.1772 0.1830 0.1739 0.1780 2.15 0.0293 0.0291 0.0292 0.1716 0.1744 0.1671 0.1710 2.20 0.0279 0.0277 0.0280 0.1637 0.1660 0.1603 0.1633 2.25 0.0263 0.0264 0.0275 0.1540 0.1581 0.1575 01565 2.30 0.0263 0.0252 0.0270 0.1544 0.1508 0.1548 0.1533

Calc Number: GEO.HBBP.03.02 Rev Number: 0 Sheet Number: 100 of 349 Date: 08/27/03 2.35 0.0259 0.0246 0.0258 0.1520 0.1476 0.1479 0.1492 2.40 0.0246 0.0246 0.0240 0.1444 0.1476 0.1374 0.1431 2.50 0.0223 0.0223 0.0223 0.1310 0.1334 0.1278 0.1307 2.60 0.0218 0.0222 0.0208 0.1277 0.1329 0.1193 0.1266 2.70 0.0200 0.0203 0.0197 0.1173 0.1213 0.1127 0.1171 2.80 0.0186 0.0186 0.0185 0.1090 0.1112 0.1060 0.1087

-2.90 0.0182 -0.01 0.0174 0:1066 0.1059 0.0994

' 0.1040 3.00 0.0178 0.0168 0.0163 0.1042 0.1008 0.0933 0.0994 3.10 0.0167 0.0160 0.0153 0.0981 0.0956 0.0876 0.0938 3.20 0.0153 0.0150 0.0144 0.0897 0.0900 0.0824 0.0874 3.30 0.0137 0.0141 _0.0136 0.0803 0.0842 0.0781 0.0809 3.40 0.0131 0.0131 0.0130 0.0765 0.0782 0.0742 0.0763 3.50 0.0126 0.0120 0.0123 0.0737 0.0721 0.0706 0.0721 3.60 0.0122 0.0111 0.0118 0.0716 0.0662 0.0673 0.0684 3.70 0.0117 0.0105 0.0112 0.0684 0.0631 0.0642 0.0652 3.80 0.0111 0.0101 0.0107 0.0650 0.0604 0.0612 0.0622 3.90 0.0103 6.00'4 0.0102 0.0604 "0.0566 0.0584 0.0585 4.00.0.0094 0.0087 0.0097 0.0551 0.0519 0.0556 0.0542 4.10 0.0088 0.0083 0.0092 0.0513 0.0497 0.0529 0.0513 4.20 0.0085 0.0080 0.0088 0.0497 0.0480 0.0503 0.0493 4.30 0.0082 0.0077 0.0083 0.0479 0.0463 0.0477 0.0473 4.40 0.0078 0.0075 0.0079 0.0458 0.0448 0.0452 0.0453 4.50 0.0074 0.0072 0.0075 0.0434 0.0433 0.0427 0.0431 4.60 0.0069 0.0070 0.0071 0.0406 0.0418 0.0404 0.0409 4.70 0.0064 0.0067 0.0067 0.0375 0.0403 0.0381 0.0386 4.80 0.0062 0.0065 0.0063 0.0361 0.0389 0.0359 0.0370 4.90 0.0060 0.0063 0.0059 0.0351 0.0375 0.0338 0.0355 5.00 0.0059 0.0060 0.0056 0.0346 0.0361 0.0318 0.0342 5.10 0.0058 0.0058 0.0052 0.0339 0.0347 0.0298 0.0328 5.20 0.0056 0.0056 0.0049 0.0328 0.0335 0.0280 0.0314 5.40 0.0054 0.0052 0.0043 0.0316 0.0310 0.0246 0.0291 5.60 0.0050 0.0048 0.0041 0.0293 0.0287 0.0234 0.0271 5.80 0.0045 0.0044 0.0041 0.0261 0.0265 0.0232 0.0253 6.00 0.0039 0.0041 0.0038 0.0231 0.0246 0.0218 0.0232 6.20 0.0035 0.0038 0.0038 0.0206 0.0228 0.0215 0.0216 6.40 0.0033 0.0035 0.0035 0.0193 0.0211 0.0202 0.0202 6.60 0.0032 0.0033 0.0034 0.0187 0.0196 0.0194 0.0192 6.80 0.0031 0.0031 0.0031 0.0180 0.0183 0.0177 0.0180 7.00 0.0029 0.0028 0.0028 0.0172 0.0170 0.0160 0.0167 7.20 0.0028 0.0027 0.0025 0.0164 0.0159 0.0142 0.0155 7.40 0.0026 0.0025 0.0021 0.0155 0.0148 0.0121 0.0141 7.60 0.0025 0.0023 0.0019 0.0147 0.0138 0.0110 0.0132 7.80 0.0024 0.0022 0.0019 0.0138 0.0129 0.0107 0.0125 8.00 0.0022 0.0020 0.0018 0.0130 0.0122 0.0103 0.0118 8.50 0.0019 0.0017 0.0015 0.0111 0.0104 0.0087 0.0101 9.00 0.0016 0.0015 0.0013 0.0095 0.0090:

0.0075 0.0087 9.50 0.0014 0.0013 0.0012 0.0081 0.0078 0.0067 0.0075 10.00 0.0012 0.0011 0.0011 0.0070 0.0068 0.0061 0.0066

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 101 of 349 Date: 08/27/03 Table 9.2 Response spectra or input rock motions for M=7.0 Response Spectra of Normalized Spectral Shape of Input input Rock Motions (g)

Rock Motions Per Average (sec)

Set I Set 2 Set 3 Set I Set 2 Set 3 0.01 0.6588 0.6699

..Q.6655 1.0000 1.0000 1.0000 1.0000 0.03 0.6608 0.6536 d.6527 *i.0029 0.975?

0.9808 0.9865 0.04 0.7601 0.7364 0.7470 1.1536 1.0993 1.1225 1.1251 0.05 0.8261 0.8205 0.8299 1.2538 1.2249 1.2471 1.2419 0.06 0.9160 0.9003 0.9372 1.3902 1.3440 1.4084 1.3809 0.07 1.0028 0.9866 1.0132 1.5220 1.4728 1.5226 1.5058 0.08 1.0923 1.0899 1.0690 1.6579 1.6271 1.6064 1.6305 0.09 1.1348 1.1565 1.1605 1.7223 1.7265 1.7438 1.7309 0.10 1.2121 1.2240 1.2026 1.8398 1.8272 1.8072 1.8247 0.11 1.3233 1.2686 1.2812 2.0085 1.8938 1.9253 1.9425 0.12 1.3444 1.3175 1.3534 2.0405 1.9668 2.0338 2.0137 0.13 1.3929 1.3360

'1.3901 2.1141 19944 2.0889 2.0658 0.14 1.4683 1.4346 1.3840 2.2286 2.1417 2.07971 2.1500 0.15 1.4469 1.4392 1.4678 2.1961 2.1485 2.2056 2.1834 0.16 1.4416 1.4710 1.4802 2.1881 2.1960 2.2243 2.2028 0.17 1.4523 1.5025 1.4299 2.2044 2.2430 2.1488 2.1987 0.18 1.5195 1.4561 1.5696 2.3063 2.1738 2.3586 2.2796 0.19 1.4793 1.4782 1.4657 2.2452 2.2067 2.2025 2.2181 0.20 1.4697 1.4687 1.5631 2.2307 2.1925 2.3489 2.2574 0.21 1.4733 1.4637 1.4541 2.2362 2.1850 2.1852 2.2021 0.22 1.4906 1.4953 1.5049 2.2625 2.2322 2.2614 2.2520 0.23 1.4493 1.4361 1.4497 2.1998 2.1439 2.1786 2.1741 0.24 1.4510 1.4883 1.4920 2.2023 2.2217 2.2421 2.2220 0.25 1.4480 1.4663 1.4419 2.1978 2.1889 2.1667 2.1845 0.26 1.4867 1.3771 1.4306 2.2565 2.0558 2.1498 2.1540 0.27 1.3646 1.4225 1.4357 2.0712 2.1236 2.1575 2.1174 0.28 1.4276 1.4160 1.4174 2.1669 2.1138 2.1299 2.1369 0.29 1.4328 1.4181 1.4027 2.1747 2.1170 2.1079 2.1332 0.30 1.3647 1.3747 1.4095 2.0714 2.0522 2.1180 2.0805 0.31 1.3760 1.3337 1.3731 2.0885 1.9909 2.0634 2.0476 0.32_ 1.3608 1.3950 1.3493 2.0655 2.0826 2.0276 2.0586 0.33 1.3034 1.3086 1.3313 11.9783 1.9536 2.0006 1.9775 0.34 1.3138 1.2899 1.3210 1.9941 1.9257 1.9850 1.9683 0.35 1.3385 1.2686 1.2979 2.0316 1.8939 1.9503 1.9586 0.36 1.3062 1.2785 1.2737 1.9825 1.9085 1.9140 1.9350 0.37 1.2733 1.2492 1.2575 1.9326 1.8649 1.8896 1.8957 0.38 1.2859 1.2391 1.2450 1.9517 1.8498 1.8709 1.8908 0.39 1.2350 1.2041 1.2281 1.8746 1.7976 1.8455 1.8392 0.40 1.1552 1.1704 1.2178 1.7534 1.7472 1.8300 1.7769 0.41 1.0952 1.1777 1.2002 1.6624 1.7582 1.8036 1.7414 0.42 1.0986 1.1574 1.1771 1.6674 1.7278' 1.7688 1.7213 0.43 1.1185 1.1287 1.1595 1.6977 1.6849 1.7424 1.7083 0.44 1.1494 1.1396 1.1398 1.7446 1.7013 1.7127 1.7195 0.45 1.1578 1.1223 1.0942 1.7574 1.6754 1.6443 1.6924 0.46 1.1337 1.0952 1.0985 1.7207 1.6349 1.6507 1.6688 0.47 1.1018 1.0654 1.0927 1.6723 1.5904 1.6421 1.6349 0.48 1.0711 1.0514 1.0674 1.62571 1.5696 1.6039 1.5997 0.49 1.0446 1.0483 1.0482 1.5854 1.5650 1.5751 1.5752 0.50 1.0210 1.0424 1.0279 1.5497 1.5561 1.5447 1.5502 0.51 1.0001 1.0297 1.0165 1.5179 1.5371 1.5275 1.2275

Cale Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 102 of 349 Date: 08/27/03 0.52 0.9822 1.0097 0.9996 1.4908 1.5073 1.5021 1.5001 0.53 0.9662 0.9868 0.9758 1.4665 1.4731 1.4664 1.4687 0.54 0.9506 0.9626 0.9507 1.4429 1.4370 1.4286 1.4362 0.55 0.9351 0.9393 0.9299 1.4193 1.4022 1.3973 1.4063 0.56 0.9196 0.9191 0.9147 1.3958 1.3720 1.3746 1.3808

-0.57 0.9044-0.9030 0.9024

.1.3727 1.3481-1.3561 1.3590.1 0.58 0.8895 0.8887 0.8900 1.3501 1.3266 1.3375 1.3381 0.60 0.8605 0.8813 0.8602 1.3060 1.3156 1.2927 1.3048 0.62 0.8281 0.8530 0.8330 1.2568 1.2733 1.2518 1.2606 0.64 0.7946 0.8687 0.8084 1.2060 1.2969 1.2148 1.2392 0.66 0.7672 0.8216 0.7803 1.1645 1.2265 1.1725 1.1878 0.68 0.7482 0.7554 0.7519 1.1357 1.1277 1.1299 1.1311 0.70 0.7330 0.7220 0.7312 1.1125 1.0778 1.0988 1.0964 0.72 0.7161 0.7204 0.7167 1.0869 1.0755 1.0771 1.0798 0.74 0.6964 0.7211 0.7008 1.0571 1.0765 1.0531 1.0622 0.76 0.6757 0.7040 0.6802

-1 0255 1.0510

-1.0222 1.0329 0.78 0.6556 0.6761 0.6579 0.9950 1.0093 0.9886 0.9976 0.80 0.6366 0.6405 0.6378 0.9662 0.9561 0.9584 0.9602 0.82 0.6184 0.5835 0.6204 0.9386 0.8710 0.9323 0.9140 0.84 0.6008 0.5967 0.6032 0.9119 0.8908 0.9065 0.9031 0.86 0.5845 0.5709 0.5828 0.8871 0.8522 0.8758 0.8717 0.88 0.5697 0.5341 0.5646 0.8647 0.7974 0.8484 0.8368 0.90 0.5565 0.5663 0.5600 0.8447 0.8454 0.8415 0.8439 0.92 0.5444 0.5723 0.5504 0.8263 0.8543 0.8271 0.8359 0.94 0.5326 0.5570 0.5385 0.8083 0.8315 0.8092 0.8163 0.96 0.5208 0.5318 0.5232 0.7904 0.7939 0.7862 0.7902 0.98 0.5101 0.5080 0.5056 0.7742 0.7583 0.7597 0.7641 1.00 0.4998 0.4972 0.4875 0.7585 0.7422 0.7326 0.7444 1.05 0.4677 0.4553 0.4573 0.7098 0.6797 0.6871 0.6922 1 :10 0.4355 0.4204 0.4341 0.6609 0.6275 0.6523 0.6469 1.15 0.4118 0.4378 0.4112 0.6250 0.6536 0.6179 0.6322 1.20 0.3947 0.4193 0.3882 0.5990 0.6260 0.5833 0.6028 1.25 0.3787 0.4004 0.3671 0.5748 0.5977 0.5516 0.5747 1.30 0.3586 0.3729 0.3478 0.5443 0.5567 0.5227 0.5412 1.35 0.3341 0.3400 0.3282 0.5071 0.5075 0.4932 0.5026 1.40 0.3148 0.3186 0.3180 0.4779 0.4756 0A778 0.4771 1.45 0.3031 0.3265 0.3076 0.4600 0.4874 0.4622 0.4699 1.50 0.2880 0.3330 0.2931 0.4372 - 0.4971 0.4404 0.4582 1.55 0.2737 0.3105 0.2782 0A154 0.4636 0.4181 0.4324 1.60 0.2615 0.2670 0.2646 0.3969 0.3986 0.3976 0.3977 1.65 0.2510 0.2449 0.2516 0.3809 0.3657 0.3781 0.3749 1.70 0.2407 0.2322 02410 0.3654 0.3466 0.3622 0.3581 1.75 0.2296 02315 _0.2327 0.3485 0.3455 0.3496 0.3479 1.80 0.2211 0.2155 0.2255 0.3356 0.3217 0.3389 0.3321 1.85 0.2118 0.2092 0.2185 0.3214 0.3122 0.3283 0.3206 1.90 0.2053 0.1988 0.2106 0.3115 0.2967 0.3164 0.3082 1.95 0.2000 0.1914 02013 0.3035 0.2857 0.3025 0.2972 2.00 0.1939 0.1856 0.1905 02942 0.2771 0.2862 0.2858 2.05 0.1871 0.1802 0.1787 0.2839 0.2690 0.2686 0.2738 2.10 0.1800 0.1756 0.1743 0.2732 0.2621 0.2619 0.2657 2.15 0.1729

.0.1710 0.1691 02624 0.2553 0.2542 0.2573 2.20 0.1664 0.1665 0.1635 0.2525 0.2485 0.2457 0.2489 2.25 0.1614 0.1616 0.1578 0.2450 0.2412 0.2371 0.2411 2.30 0.1564 0.1562 0.1525 0.2374 0.2332 0.2291 0.2332 2.35 0.1515 0.1506 (0.1474 0.2299 0.2247 0.2215 0.2254

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 103 of 349 Date: 08/27/03 2.40 0.1465 0.1446 0.1425 0.2224 0.2158 0.2141 0.2174 2.50 0.1370 0.1321 0.1329 0.2079 0.1972 0.1997 0.2016 2.60 0.1281 0.1192 0.1260 0.1945 0.1779 0.1893 0.1872 2.70 0.1201 0.1161 0.1201 0.1822 0.1733 0.1804 0.1786 2.80 0.1140 0.1185 0.1142 0.1731 0.1769 0.1716 0.1739

-2.90 0.1088 0.1129.. 0.1090 0.1652 0.1685 0.1638

..0.1658 3.00 0.1035 0.1100 0.0994 0.1572 0.1642 0.1494 0.1569 3.10 0.0980 0.1010 0.0930 0.1488 0.1507 0.1398 0.1464 3.20 0.0923 0.0946 0.0923 0.1401 0.1413 0.1387 0.1400 3.30 0.0865 0.0863 0.0848 0.1313 0.1288 0.1274 0.1292 3.40 0.0808 0.0816 0.0800 0.1227 0.1218 0.1202 0.1216 3.50 0.0749 0.0810 0.0762 0.1136 0.1208 0.1144 0.1163 3.60 0.0712 0.0816 0.0726 0.1081 0.1218 0.1090 0.1130 3.70 0.0697 0.0800 0.0696 0.1058 0.1195 0.1046 0.1100 3.80 0.0669 0.0770 0.0667 0.1016 0.1150 0.1003 0.1056

-3.-90.

0.0632 0.0705,..

0.0639 0.0959.

0.1052 0.0961 0.0991 4.00 0.0589 0.0645 0.0612 0.0894 0.0962 0.0919 0.0925 4.10 0.0566 0.0596 0.0585 0.0859 0.0890 0.0879 0.0876 4.20 0.0554 0.0568 0.0559 0.0841 0.0848 0.0840 0.0843 4.30 0.0535 0.0541 0.0534 0.0812 0.0807 0.0802 0.0807 4.40 0.0511 0.0508 0.0509 0.0775 0.0759 0.0765 0.0766 4.50 0.0483 0.0473 0.0485 0.0733 0.0707 0.0729 0.0723 4.60 0.0453 0.0449 0.0461 0.0688 0.0670 0.0693 0.0684 4.70 0.0449 0.0432 0.0439 0.0682 0.0644 0.0659 0.0662 4.80 0.0469 0.0429 0.0422 0.0712 _0.0641 0.0634 0.0662 4.90 0.0475 0.0433 0.0412 0.0720 0.0646 0.0618 0.0661 5.00 0.0466 0.0427 0.0400 0.0707 0.0637 0.0601 0.0648 5.10 0.0444 0.0410 0.0388 0.0673 0.0612 0.0583 0.0623 5.20 0.0407 0.0385 0.0376 0.0617 0.0575 0.0564 0.0585 5.40 0.0353 0.0324 0.0350 0.0536 0.0484 0.0526 0.0515 5.60 0.0324 0.0296 0.0324 0.0491 0.0442 0.0486 0.0473 5.80 0.0293 0.0261 0.0298 0.0444 0.0389 0.0448 0.0427 6.00 0.0293 0.0253.

0.0291 0.0445 0.0378 0.0437 0.0420 6.20 0.0283 0.0248 0.0283 0.0429 0.0370 0.0425 0.0408 6.40 0.0263 0.0239 0.0277 0.0399 0.0357 0.0416 0.0391 6.60 0.0236 0.0234 0.0257 0.0358 0.0350 0.0386 0.0365 6.80 0.0212 0.0226 0.0241 0.0321 0.0337 0.0362 0.0340 7.00 0.0194 0.0215 0.0215 0.0295 0.0320 0.0323 0.0313 7.20 0.0177 0.0202 0.0194 0.0269 0.0301 0.0292 0.0287 7.40 0.0161 0.0187 0.0181 0.0244 0.0279 0.0272 0.0265 7.60 0.0145 0.0172 0.0167 0.0220 0.0256 0.0251 0.0242 7.80 0.0130 0.0170 0.0157 0.0198 0.0254 0.0235 0.0229 8.00 0.0124 0.0167 0.0150 0.0188 0.0249 0.0225 0.0221 8.50 0.0126 0.0149 0.0135 0.0191 0.0223 0.0203 0.0206 9.00 0.0109 0.0149 0.0121 0.0166 0.0223 0.0182 0.0190 9.50 0.0085 0.0135 0.0109 0.0128 0.0202 0.0164 0.0165 10.00 0.0074 0.0117 0.0099 0.0112 0.0174 I 0.0148 0.0145

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 104 of 349 Date: 08/27/03 Table 9.3 Response spectra or input rock motions for M=7.8 Response Spectra of Normalized Spectral Shape of Input Input Rock Motions (g)

Rock Motions Per Average (sec)

Set I Set 2 Set 3 Set I Set 2 Set 3 0.01 O.;G74 0.8963 0;9324

-.. 0000 1.0000 1.0000 1.0000 0.03 0.9136 0.9008 0.8992 1.0069 1.0051 0.9644 0.9921 0.04 1.1041 1.0990 1.1255 1.2168 1.2262 1.2072 1.2167 0.05 1.3001 1.2845 1.2785 1.4328 1.4331 1.3713 1.4124 0.06 1.4125 1.3987 1.4271 1.5567 1.5606 1.5307 1.5493 0.07 1.5731 1.5680 1.5130 1.7337 1.7495 1.6228 1.7020 0.08 1.6966 1.6320 1.6419 1.8698 1.8209 1.7610 1.8172 0.09 1.7981 1.7049 1.7121 1.9817 1.9022 1.8363 1.9067 0.10 1.8101 1.7550 1.7684 1.9949 1.9581 1.8967 1.9499 0.11 1.8618 1.8340 1.7936 2.0519 2.0462 1.9238 2.0073 0.12 -:-1.8608 1.8582 1.8671 2.0508 2.0733.1 2.Q026 2.0422 0.13 1.9800 1.9210 1.8084 2.1822 2.1434 1.9396 2.0884 0.14 1.9495 1.9573 1.9612 2.1486 2.1839 2.1035 2.1453 0.15 1.9926 1.9944 2.0208 2.1960 2.2252 2.1674 2.1962 0.16 1.9891 2.0021 2.0210 2.1923 2.2338 2.1676 2.1979 0.17 2.0659 2.0359 2.0595 2.2768 2.2715 2.2089 2.2524 0.18 2.0623

.2.0798 2.0614 2.2729 2.3205 2.2110 2.2681 0.19 2.0716 2.0806 2.0707 2.2832 2.3214 2.2209 2.2752 0.20 2.0872 2.0861 2.0909 2.3003 2.3276 2.2426 2.2902 0.21 2.1244 2.0736 2.0879 2.3413 2.3136 2.2394 2.2981 0.22 2.1406 2.0790 2.0678 2.3592 2.3196 2.217S 2.2989 0.23 2.0772 2.0930 2.0799 2.2893 2.3352 2.2308 2.2851 0.24 2.1110 2.0859 2.1095 2.3266 2.3273 2.2626 2.3055 0.25 2.1425 2.0665 2.0336 2.3613 2.3057 2.1811 2.2827 026 2.1274 2.0444 2.0955 2.3447 2.2810 2.2475 2.2911 0.27 2.0776 2.0337 2.0714 2.2898 2.2691 2.2217 2.2602 0.28 2.0524 2.0384 2.1143 2.2620 2.2743 2.2677 2.2680 0.29 2.0620 2.0418 2.0869 2.2726 2.2781 2.2383 2.2630 0.30 1.9984 2.0253 1.9810 2.2024 2.2597 2.1247 2.1956 0.31 2.0751 1.9865 2.0371 2.2869 2.2164 2.1849 2.2294 0.32 2.0128 1.9483 1.9811 2.2183 2.1738 2.1248 2.1723 0.33 1.9636 1.9231 1.9110 2.1641 2.1456 2.0497 2.1198 0.34 1.8971 1.9117 1.9261 2.0908 2.1329 2.0658 2.0965 0.35 1.8451 1.904 1.9340 2.0335 2.1253 2.0743 2.0777 0.36 1.8540 1.8933 1.9236 2.0433 2.1124 2.0632 2.0730 0.37 1.8788 1.8750 1.8453 2.0707 2.0920 1.9792 2.0473 0.38 1.8412 1.8512 1.7712 2.0292 2.0654 1.8997 1.9981 0.39 1.8582 1.8238 1.6863 2.0480 2.0349 1.8086 1.9638 0.40 1.8528 1.7945 1.8180 2.0420 2.0022 1.9499 1.9980 0.41 1.8617 1.7627 1.7872 2.0518 1.9668 1.9169 1.9785 0.42 1.7941 1.7477 1.7705 1.9773 1.9500 1.8989

-1.9421 0.43 1.8164 1.7435 1.7837 2.0019 1.9453 1.9131 1.9534 0.44 1.7764 1.6641 1.6762 1.9577 1.8568 1.7979 1.8708 0.45 1.6859 1.6954 1.6723 1.8580 1.8916 1.7937 1.8478 0.46 1.6773 1.6775 1.6741 1.8485 1.8716 1.7955 1.8385 0.47 1.7087 1.6131 1.6531 1.8832 1.7998 1.7730 1.8187 0.48 1.7084 1.5927 1.6132 1.8829 1.7770 1.7303 1.7967 0.49 1.6520 1.6026 1.6341 1.8206 1.7881 1.7526 1.7871 0.50 1.5510 1.5962 1.6221 1.7094 1.7809 1.7398 1.7434 0.51 1.4563 1.5637 1.5665 1.6050 1.7447 1.6802 1.6766 e.

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 105 of 349 Date: 08/27/03 0.52 1.4119 1.5301 1.5380 1.5560 1.7072 1.6496 1.6376 0.53 1.4090 1.5069 1.4791 1.5529 1.6813 1.5864 1.6069 0.54 1.4157 1.4942 1.4745 1.5603 1.6671 1.5814 1.6029 0.55 1.4201 1.4694 1.5086 1.5651 1.6394 1.6181 1.6075 0.56 1.4295 1.4353 1.4681 1.5755 1.6015 1.5746 1.5839 0.57 1.4322, 1.4467.

1.4218 1.5785 1.6142 1.5249

15725 0.58 1.3980 1.3644 1.4148 1.5407 1.5223 1.5175 1.5268 0.60 1.3269 1.4112 1.3272 1.4624 1.5745 1.4235

.1.4868 0.62 1.2967 1.3243 1.3495 1.4291 1 A776 I A474 1.4514 0.64 1.3448 1.3061 1.3334 -- 1.4821 1.4573 1.4301 1.4565 0.66 1.3304 1.2658 1.3178 1.4662 1.4123 1.4134 1.4306 0.68 1.2094 1.2412 1.2287 1.3328 1.3849 1.3179 1.3452 0.70 1.1762 1.2394 1.1268 1.2963 1.3828 1.2086 1.2959 0.72 1.1836 1.1777 1.1997 1.3044 1.3140 1.2867 1.3017 0.74 1.1555 1.2031 1.1541 1.2735 1.3423 1.2378 1.2845 0.76 1.1325 1.189,6.,

1.1023 1.2481

.1.3272 1.1823

, 1.2525 0.78 1.1085 1.1276 1.0937 1.2217 1.2581 1.1731 1.2176 0.80 1.0808 1.1149 1.1171 1.1911 1.2439 1.1982 1.2111 0.82 1.0513 1.0789 1.1002 1.1587 1.2038 1.1800 1.1808 0.84 1.0272 1.0419 I1.0617 1.1321 1.1625 1.1387 1.1444 0.86 1.0064 1.0771 1.0284 1.1091 1.2017 1.1031 1.1380 0.88 0.9852 1.0337 1.0065 1.0858 1.1533 1.0795 1.1062 0.90 0.9651 0.9531 0.9560 1.0637 1.0634 1.0254 1.0508 0.92 0.9471 0.9389 0.9025 1.0438 1.0476 0.9680 1.0198 0.94 0.9296 0.9785 0.8673 1.0245 1.0917 _0.9302 1.0155 0.96 0.9122 0.9783 0.8892 1.0053 1.0915 0.9538 1.0169 0.98 0.8943 0.9165 0.9169 0.9857 1.0226 0.9835 0.9973 1.00 0.8762 0.8825 0.9257 0.9656 0.9846 0.9928 0.9810 1.05 0.8318 0.8169 0.8780 0.9167 0.9114 0.9417 0.9233 1.10 0.7805 0.7802 0.8157 0.8602 0.8705 0.8749 0.8685 1.15 0.7570 0.7617 0.7594 0.8343 0.8498 0.8145 0.8329 1.20 0.7315 0.6976 0.7306 0.8062 0.7783 0.7836 0.7894 1.25 0.6698 0.7117 0.7011 0.7382 0.7941 0.7519 0.7614 1.30 0.6843 0.6781 0.6777 0.7542 0.7566 0.7268 0.7459 1.35 0.6289 0.6336 0.6473 0.6932 0.7069 0.6943 0.6981 1.40 0.6116 0.6124 0.6094 0.6740 0.6833 0.6536 0.6703 1.45 0.5934 0.5946 0.5877 0.6539 0.6634 0.6303 0.6492 1.50 0.5846 0.5601 0.5831 0.6443 0.6249 0.6254 0.6315 1.55 0.5739 0.5555 0.5709 0.6325 0.6198 0.6123 0.6215 1.60 0.5528 0.5369 0.5385 0.6092 0.5990 0.5776 0.5953 1.65 0.5292 0.5148 0.4993 0.5832 0.5743 0.5355 0.5643 1.70 0.5003 0.4946 0.4769 0.5514 0.5519 0.5115 0.5383 1.75 0.4725 0.4707 0.4731 0.5207 0.5252 0.5074 0.5178 1.80 0.4490 0.4719 0.4651 0.4949 0.5265 0.4989 0.5068 1.85 0.4349 0.4779 0.4621 0.4793 0.5332 0.4957 0.5027 1.90 0.4333 0.4358 0.4476 0.4776 0.4862 0.4801 0.4813 1.95 0.4285 0.4190 0.4170 0.4722 0.4675 0.4473 0.4623 2.00 0.4199 0.4323 0.4115 0.4628 0.4823 0.4414 0.4622 2.05 0.4068 0.4178 0.4015 0.4483 0.4662 0.4307 0.4484 2.10 0.3894 0.3753 0.3856 0.4291 0.4187 0.4136 0.4205 2.15 0.3690 0.3661 0.3673 0.4066 0.4085 0.3940 0.4030 2.20 0.3533 0.3510 0.3592 0.3893 0.3916 0.3852 0.3887 2.25 0.3425 0.3352 0.3525 0.3775 0.3740 0.3781 0.3765 2.30 0.3323 0.3338 0.3426 0.3663 0.3725 0.3674 0.3687 2.35 0.3231 0.3285 0.3289 0.3561 0.3665 0.3528 0.3585

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 106 of 349

____Date: 08/27/03 2.40 0.3146 0.3202 0.3119 0.3467 0.3573 0.3345 0.3462 2.50 0.2988 0.2983 0.3049 0.3293 0.3328 0.3270 0.3297 2.60 0.2833 0.2816 0.2836 0.3122 0.3142 0.3042 0.3102 2.70 0.2681 0.2686 0.2705 0.2954 02997 02901 0.2951 2.80 0.2541 0.2512 0.2600 0.2801 0.2802 0.2789 0.2797 2.90 0.2420 0.2476 0.2536 0.2667 0.2763 0.2720 0.2717 3.00.

0.2315 0.2411 02440 0.2552 0.2690 0.2617 0.2620 3.10 0.2222 0.2321 0.2288 0.2448 0.2590 0.2454 0.2497 3.20 0.2130 0.2214 0.2097 0.2347 0.2470 0.2249 0.2355 3.30 0.2035 0.2092 0.1881 0.2242 0.2334 0.2017 0.2198 3.40 0.1956 0.1954 0.1666 0.2156 0.2180 0.1786 0.2041 3.50 0.1909 0.1807 0.1481 0.2104 0.2016 0.1589 0.1903 3.60 0.1843 0.1656 0.1351 0.2031 0.1848 0.1449 0.1776 3.70 0.1834 0.1616 0.1318 0.2022 0.1803 0.1414 0.1746 3.80 0.1804 0.1699 0.1325 0.1988 0.1895 0.1421.

0.1768 3.90 0.1735 0.1777 0.1355 0.1912 0.1983 0.1454 0.1783 4.00 0.1640 0.1738 0.1382 0.1807 0.1939 0.1482 0.1743 4.10 0.1537 0.1579 0.1389 0.1694 0.1762 0.1490 0.1649.

4.20 0.1448 0.1375 0.1409 0.1596 0.1534 0.1512-0.1547 4.30 0.1343 0.1174 0.1432 0.1480 0.1310 0.1536 0.1442 4.40 0.1380 0.1070 0.1415 0.1521 0.1194 0.1517 0.1411 4.50 0.1401 0.1053 0.1361 0.1544 0.1175 0.1459 0.1393 4.60 0.1358 0.1072 0.1276 0.1497 0.1196 0.1369 0.1354 4.70 0.1262 0.1076 0.1167 0.1391 0.1201 0.1252 0.1281 4.80 0.1127 0.1045 0.1114 0.1242 0.1165 0.1194 0.1200 4.90 0.1112 0.1013 0.1090 0.1226 0.1130 0.1169 0.1175 5.00 0.1102 0.0932 0.1064 0.1215 0.1040 0.1141 0.1132 5.10 0.1070 0.0828 0.1002 0.1180 0.0924 0.1074 0.1059 5.20 0.1029 0.0796 0.0915 0.1134 0.0888 0.0981 0.1001 5.40 0.0921 0.0776 0.0792 0.1015 0.0866 0.0849 0.0910 5.60 0.0853 0.0811 0.0792 0.0940 0.0905 0.0849 0.0898 5.80 0.0801 0.0820 0.0777 0.0883 0.0915 0.0833 0.0877 6.00 0.0752 0.0829 0.0756 0.0829 0.0925 0.0810 0.0855 6.20 0.0711 0.0766 0.0728 0.0783 0.0854 0.0780 0.0806 6.40 0.0678 0.0705 0.0700 0.0748 0.0786 0.0751 0.0762 6.60 0.0703 0.0662 0.0678 0.0775 0.0738 0.0727 0.0747 6.80 0.0703 0.0647 0.0638 0.0774 0.0722 0.0684 0.0727 7.00 0.0677 0.0626 0.0588 0.0746 0.0698 0.0631 0.0692 7.20 0.0634 0.0626 0.0547 0.0699 0.0698 0.0587 0.0661 7.40 0.0620 0.0605 0.0518 0.0683 0.0675 0.0555 0.0638

.7.60 0.0593 0.0571 0.0476 0.0654 0.0637 0.0510 0.0600 7.80 0.0557 0.0525 0.0449 0.0614 0.0586 0.0482 0.0561 8.00 0.0513 0.0472 0.0445 0.0566 0.0527 0.0478 0.0524 8.50 0.0396 0.0420 0.0427 0.0437 0.0469 0.0458 0.0455 9.00 0.0335 0.0376 0.0385 0.0369 0.0420 0.0413 0.0401 9.50 0.0276 0.0323 0.0345 0.0304 0.0361 0.0370 0.0345 10.00 0.0221 0.0271 0.0299 0.0244 0.0302 0.0320 0.0289

-j

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 107 of 349 Date: 08/27/03 9.2 Step 2: Compute Amplification Factors Amplification factors are computed for the 13 input rock PGA levels used in the site response analysis: O.lg, 0.2g, 0.3g, 0.4g, O.5g, 0.6g, 0.7g, 0.8g, 0.9g, 1.Og, 1.2g, 1.4g, t -and I-.6g,--The-amplification factor is computed using eq. 7-1 where tWe surface response_.-

spectra is obtained from Tables 6-4 to 6-12 and the corresponding input response spectra is obtained by scaling the individual spectral shapes listed in Tables 9-1 to 9-3 by the input rock PGA value.

The average of the amplification factors from three input motions for each magnitude and soil profile is computed. The resulting average amplification factors for the median, lower and upper profile are listed in Table 9-4 to 9-6, Tables 9-7 to 9-9, and Tables 9-10 to 9-

12, respectively,--.-e2

~

-z

Calc Number: GEO.HBEP.03).02 Rev Number: 0 Sheet Number: 1 08 of. 349 Date: 08/27/03 Table 9-I. Averae amplification factors ror the nedian sol profile, M=6.0.

Per Sec 0.lg 0.2p 0.3 0.4g 0.5ig 0.6g 0.7_q 0.8i2 0.9sg 1.0s 1.2R 1.4g 1.6sg 0.01 1.7786 1.6002 1.4221 1.2761 1.1575 1.0643 1.0193 0.9764 0.9386 0.9077 0.14495 0.7964 0.7152 0.03 1.9870 1.7743 1.5656 1.3996 1.2670 1.1630 1.1072 1.0583 1.0173 0.9837 0.9203 0.8518 0.77403 0.04 1.8634 1.6426 1.4370 1.2772 1.1510 1.0490 0.9964 0.9499 0.9083 0.8781 0.8208 0.7591 0.6895 0.05 1.8128 1.5808 1.3769 1.2195 1.0919 0.9883 0.9304 0.8814 0.8372 0.8055 0.7531 0.6967 0.6329 0.06

-l.1R268 1.5117 f.3657' 1.1s44 1.0290 '1-0.9234. 10.9662' 4'0.9169 10.7715 0O.7286

-0.6792 0:6271'- `0:692 0.07 1.8296 1.4773 1.2767 1.1057 0.9671 0.8670 0.8075 0.7606 10.7190 0.6784 0.6233 0.5788 0.5276 0.08 1.9906

.1.6529 1.3941 1.2064 1.085 1 0.9825 0.9002 0.8328 10.7739 0.7197 0.6393 0.5816 0.5220 0.09 1.9354 1.6680 1.4127 1.2316 1.1008 0.9931 0.9046 0.8315 0.7681 0.7107 0.6218 0.5533 0.4951 0.10 2.0215 1.6758 1.4390 1.2689 1.1234 0.9915 0.8831 0.7938 0.7180 0.6687 0.5890 0.5261 0.4-700 0.11 2.2488 1.8193 1.5136 1.3289 11.1738 1.0509 0.9391 0.8398 0.7526 0.6734 0.5620 0.5054 0.4526 0.12 2.2937 1.8815 1.6211 1.4292 1.2691 1.1252 0.9998 0.8908 0.7954 0.7059 0.5956 0.548 0.4652 0.13 2.4338 2.0600 1.7482 1.5369 1.3604 1.1958 1.0526 0.9334 0.8445 0.7722 0.6683 0.5872 0.5134 0.14 2.3936 2.0552 1.7675 1.5580 1.3859 1.2352 1.1139 1.0126 0.9226 0.8443 0.7243 0.6315 0.552:2 0.15 2.1766 1.9983 1.7477 1.5660 1.4311 1.2996 1.1736 1.0623 10.9651 0.8766 0.7341' 0.6412 0.5652 0.16 2.2:302 1.9450 1.7320 1.6019 1.5131 1.4162 1.3075 1.1952 1.0914 0.9955 0.8420 0.7183 f0.6153 0.17 2.3690 2.1737 1.8990 1.6871 1.5430 1.4481 1.3505 1.2473 1.1476 1.0452 0.8902 0.7720 10.6707 0.1I 8

2. 1~837 1.9656 1.7849 1.6649 1f.5717 1.4671 1.3614 1.26111 1.1748 1.4089 --- 69-292 0.7947' 649 7 0 0.19 2.4476 2.1319

-1.9070 1.7431 1.6491 1.5724 1.486-6 1.3892 1.2947 1.1981 11.0313 0.9053 10.8003 0.20 2.5966 2.2572 2.0518 1.9051 1.7725 1.6604 1.5676 1.4717 1.3734 1.2673 11.0741 0.9241 0.8059 0.21 2.811.1 2.5364 2.2239 1.9866 1.8249 1.7038 1.5946 1.4873 1.3838 1.2761 1.0855 0.9459 0.8,263 0.22 2.7878 2.5529 2.2787 2.0700 1.9107 1.7726 1.6492 1.5327 1.4246 1.3170 1.1266 0.9860 0.8613 0.23 2.6585 2.5106 2.3690 2.2122 2.0575 I.9069 1.7728 1.6489 1.5366 1.4251 1.2265 1.0629, 0.9262 0.24 2.5690 2.5214 2.3848 2.2353 2.0896 1.9434 1.8074 1.6822 1.5702 1.4619 1.2635 1.0974 0.9557 0.25 2.5695 2.5336 2.4170 2.2852 2.1465 1.9973 1.8517 1.7175 1.6045 1.4930 1.2978 1.1291 0.9832 0.26 2.7117 2.6384 2.4992 2.3693 2.2446 2.1174 1.9926 1.8724 1.7584 1.6394 1.4121 1.2144 1.0460 0.27 2.7467 2.6591 2.5596 2.4518 2.3410 2.2321 2.1172 1.9951 1.8709 1.7373 1.4850 1.2833 1.1087 0.28 2.6215 2.6002 2.5233 2.4090 2.3086 2.2092 2.1029 1.9903 1.8744 1.7515 1.5035 1.2921 1.1138 0.29 2.4455 2.5164 2.4286 2.3235 2.2049 2.1269 2.0529 1.9776 1.8991 1.8186 11.6323 1.4235 1.2299 0.30 2.2454 2.3315 2.3360 2.2808 2.1835 12.1106 2.0552 1.9932 1.9401 1.8739 1.6922 1.4852 1.2931 0.31 2.1438 2.2031 2.2162 2.2172 2.1878 2.1405 2.0790 2.0061 1.9313 1.R585 1.6778 1.4812 1.2894 0.32.

2.0996 2.1665 2.1861 2.1811 2.1508 2.1160 2.0724 2.0224 1.9637 1.8958 1.7215 1.5298 1.3730 0.33 2.0819 2.1447 2.1829 2.1942 2.1753 2.1489 2.1124 2.0647 2.0118 1.9432 1.7685 1.6324 1.4799 0.34 2.0200 1.9391 1.9884 2.0128 2.0063 1.9897 1.9645 1.9309 1.8899 1.8460 1.7660 1.6551 1.5103 0.35 2.0227 1.9042 1.8720 1.8786 1.8768 1.8773 1.8769 1.8726 1.8644 1.8461 1.7886 1.6875 1.5502 0.36 2.04 11 1.9259 1.8598 1.8675 1.8731 1.8808 1.8877 1.8905 1.8905 1.8796 1.8356 1.7452 1.6118 0.37 2.0308 1.9108 1.8015 1.7364 1.7167 1.7203 1.7273 1.7386 1.7459 1.7422 1.7184 1.6815 1.5985 0.38 2.0519 1.9453 1;8327 1.7438 1.7075 1.6817 1.6634 1.6568 1.6625 1.6618 1.6523 11.6281 1.5688 0.39 2.1038 1.9336 1.8252 1.7374 1.6673 1.6386 11.6190 11.6006 1.5803 11.5687 11.5593 11.5466 1.5016 0.40 2.1784 1.9790 1.8482 1.7558 1.6777 1.6196 1.5881 11.5685 1.5510 1.5269 1.5129 1.5075 1.4667 0.41 2.2496 2.0468 1.8893 1.7948 1.7116 1.6503 1.5973 1.5585 1.5400 1.5161 1.4806 1.4796 1.4536 0.42 2.3395 2.1490 1.9841 1.8759 1.7882 1.7167 1.6573 1.6050 1.5600 1.5253 1.4812 1.4415 1.4302 0.43 2.3623 2.1346 1.9675 1.8670 1.7855 1.7168 1.6570 1.6031 1.5573 1.5139 1.4651 1.4268 1.3930 0.44 2.5900 2.2823 2.0675 1.9405 1.8230 1.7504 1.6864 1.6256 1.5710 1.5143 1.4651 1.4164 1.4007 0.45 2.5218 2.2947 2.1291 1.9859 1.8532 1.7897 1.7271 1.6680 1.6134 1.5537 1.4534 1.3789 1.3453 0.46 2.4831 2.2997 2.1481 2.0277 1.9047 1.8176 1.7561 1.6975 1.6430 1.5835 1.4841 1.3935 1.3386 0.47 2.3843 2.2685 2.1478 2.0374 1.9220 1.8317 1.7717 11.7140 1.6606 1.6018 1.5033 1.4129 1.3297 0.48 2.3420 2.2699 2.1570 2.0380 1.9251 1.8519 1.7919 1.7337 1.~6793 1.6205 1.5210 1.4299 1.3459 0.49 2.3487 2.2895 2.1809 2.0696 1.9611 1.8777 1.8149 1.7547 1.6988 1.6375 1.5358 1.4429 1.3583 0.50 2.3135 2.2683 2.1865 2.0986 11.9986 1.9099 1.8420 1.7780 1.7198 1.6569 1.5530 1.4590 1.3738 0.51 2.2898 2.2561 2.1801 2.1042 2.0093 1.9285 1.8793 1.8266 1.7736 1.7127 1.6097 I.5147 1.4219 0.52 2.1566 2.1304 2.0759 2.0568 2.0198 1.9614 1.8889 1.8313 1.7784 1.7179 1.6147 1.5218 1.4311 0.53 2.0606 2.0683 2.0986 2.0997 2.0632 2.0045 1.9316 1.8574 1.7828 1.7232 1.6202 11.5292 11.4409 0.54 2.0342 2.0683 2.0983 2.1037 2.0770 2.0295 1.9671 1.8987 1.8264 1.7394 1.6315 1.5394 11.4527 0.55 1.9883 2.0159 2.0587 2.0734 2.0526 2.0109 1.9545 1.8916 1.8238 1.7523 1.6378 1.5407 1.4555 0.56 1.9579 1.9686 1.9929 2.0109 1.9954 1.9599 1.9106 1.8624 1.8175 1.7612 1.6515 1.5420 11.4559 0.57 1.9369 1.9501 1.9479 1.9597 1.9525 1.9324 1.9019 1.8656 1.8248 1.7718 1.6659 1.5591 1.4598 0.58 1.9078 1.9305 1.9420 1.9457 1.9416 1.9261 1.9006 1.8682 1.8302 1.7802 1.6768 1.5738 1.4748 0.60 1.8813 1.9206 1.9377 1.9464 1.9380 1.9202 1.9016 1.8747 1.8416 1.7953 1.6968 1.6164 1.5197 0.62 1.8271 1.8710 1.8937 1.9078 1.9049 1.8921 1.8721 1.8475 1.8196 1.7851 1.7444 1.6658 1.5613 0.64 1.7861 1.8242 1.8451 1.8674 1.8750 1.8709 11.8587 1.8416 11.8218 1.7957 1.7574 1.99 1.6123 0.66 1.7571 1.7980 1.8215 1.8481 1.8614 1.8633 1.8571 1.8452 1.8305 1.8104 1.7928 1.50 169 0.68 1.6775 1.7234 1.7485 1.7743 1.7922 11.8035 1.8085 1.8086 1.8059 1.7981 1.7808

1.

L8161

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 109 of 349 Date: 08/27/03 0.70 1.6460 1.6640 1.6773 1.6964 1.7150.

1.7340 1.7469 1.7546 1.7588 1.7577 1.7518 1.7437 1.6970 0.72 1.7079 1.6908 1.6650 1.6915 1.7119 1.7247 1.7334 1.739%

1.7445 1.7463 1.7476 1.7278 1.6N49 0.74 1.7255 1.7106 1.6783 1.6603 I 1.6465 1.6299 1.6259 1.6255 1.6279 1.6331 1.6630 1.6921 1.6944 0.76 1.8787 1.8353 1.7993 1.7761 1.7541 1.7268 1.7001 1.6788 1.6631 1.6628 1.6769 1.69l2 1.7100 0.78 1.9142 1.8758 1.8277 1.7995 1.7814 1.7570 1.7322 1.7172 1.7094 1.7070 1.7084 1.7064 1.7068 0.80 1.9230 1.9021 1.8557 Ug 1.172 j 1.7905 1.7698 1.7500 1.7352 1.7265 1.7227 1.720t 1.7162 1.7015 I 0.82 1.9516

.1.9348 1.8946 l 1.8627 1.8308 1.7959 1.7651 I 1.7511 1 1.7416 1 1.7371 1.7329 1 1.7263 1 1.7107 0.84 2.0030 L 9676

' 1.9079..812-1.8540 1.8239 1.7928 1.7643

-1.7416 1.7361 1.73.

1.7226 1.7067-O.86 2.0597 2.0327 1.9772 1.9295 1.8823 1.8319 1.8042 1.7782 1.7566 1.7408 1.7226 1.7104 1.6950 0.88 2.1496 2.1071 2.0406 1.9911 1.9480 1.9017 1.8545 1.8093 1.7707 1.7517 1.7320 1.71S9 1.7040 0.90 2.2347 2.1964 2.1326 2.0824 2.0390 1.9935 1.9478 1.9041 1.8634 1.8254 1.7698 1.7380 1.7062 0.92 2.2849 2.2513 2.1902 2.1405 2.0941 2.0433 1.9945 1.9501 1.9102 1.8732 1.8099 1.7574 1.7254 0.94 2.2900 2.2621 2.2064 2.1604 2.1163 2.0651 2.0142 1.9677 1.9268 1.8898 1.8261 1.7706 1.7205 0.96 2.2926 2.2700 2.2196 2.1775 2.1363 2.0868 2.0363 1.9896 1.9485 1.9113 1.8470 1.7897 1.7372 0.98 2.2942 2.2764 2.2313 2.1931 2.1549 2.1077 2.0583 2.0122 1.9714 1.9345 1.8705 1.8123 1.7575 1.00 2.2966 2.2830 2.2427 2.2083 2.1729 2.1283 2.0803 2.0352 1.9949 1.9586 1.8955 1.8370 1.7808 1.05 2.3535 2.3081 2.2779 2.2516 2.2225 2.1835 2.1397 2.0967 2.0580 2.0231 1.9631 1.9059 I.S481 1.10 2.5947 2.5268 2.4237 2.3393 2.2838 2.2461 2.2048 2.1634 2.1255 2.0913 2.0333 1.9775 1.9198 1.15 2.7151 2.6381 2.5434 2.4669 2.3908 2.3333 _2739 2.2238 2.1815 2.1421 2.0751 2.0178 1.9616 1.20 2.7893 2.7544 2.6S44 2.6249 2.5645 2.4915

  • 7.4263 2.3601 2.3045 2.2638 2.1954 2.1324 2.0680 1.25 2.7S01

'2.7731 2.7294 2.6849 2-6344 2.5697 2.5147 2.4593 2.4087 2.3689 2.2993 2.2345 2.1682 1.30 2.6622 2.6725 2.6492 2.6312 2.6155 2.5813 2.5342 2:4825 2.4383 2.3954 2.3244 2.2666 2.2069 1.35 2.5382 2.5790 2.5904 2.5930 2.5904 2.5757 2.5500 2.5166 2.4797 2.4400 2.3723 2.2973 2.2424 1.40 2.5671 2.6204 2.6447 2.6536 2.6539 2.6403 2.6167 2.5942 2.5724 2.5419 2.4742 2.4102 2.3279 1.45 2.5131 2.5716 2.6151 2.6481 2.6716 2.6847 2.68g5 2.6848 2.6739 2.6573 2.6082 2.5417 2.4612 1.50 2.5448 2.6057 2.6561 2.6935 2.7215 -

2.7440 2.7582 2.7646 2.7633 2.7555 2.7209 2.6630 2.5816 1.55 2.5093 2.5765 2.6370 2.6837.

2.7214 2.7487 2.7676 2.7793 2.7834 2.7815 2.7576 2.7090 2.6352 1.60 2.4499 2.5164 2.5761 2.6237 2.6631 2.6928 2.7143 2.7297 2.7383 2.7414 2.7284 2.6921 2.6388 1.65 2.3983 2.4538 2.5153 2.5647 2.6067 2.6395 2.6660 2.6877 2.7039 2.7163 2.7213 2.7050 2.6635 1.70 2.3771 2.4253 2.4685 2.5188 2.5665 2.6072 2.6412 2.6696 2.6922 2.7110 2.7271 2.7215 2.6904 1.75 2.3191 2.3689 2.4130 2.4530 2.5029 2.5471 2.5862 2.6206 2.6500 2.6758 2.7047 2.7103 2.6896 1.80 2.2815 2.3183 2.3462 2.3669 2.3887 2.4333 2.4732 2.5077 2.5366 2.5631 2.6024 2.6266 2.6607 1.85 2.2534 2.28S7 2.3135 2.33-18 2.3473 2.3584 2.3765 2.3949 2.4263 2.4725 2.5553 2.6508 2.7270 1.90 2.2353 2.2750 2.3032 2.3238 2.3415 2.3555 2.3662 2.3746 2.4019 2.4455 2.5594 2.6803 2.7728 1.95 2.1823 2.2263 2.2573 2.2802 2.3000 2.3164 2.3407 2.3713 2.4010 2.4407 2.5229 2.6085 2.6904 2.00 2.1339 2.1772 2.2117 2.2375 2.2599 2.2798 2.3125 2.3468 2.3802 2.4154 2.5002 2.5836 2.6678 2.05 2.0858 2.1213 2.1443 2.1662 2.1922 2.2167 2.2395 2.270S 2.3065 2.3424 2.4230 2.5079 2.5889 2.10 2.0306 2.0664 2.0925 2.1118 2.1266 2.1510 2.1773 2.2009 2.2227 2.2530 2.3258 2.4094 2.4940 2.15 2.017S 2.0474 2.0630 2.0728 2.0893 2.1029 2.1277 2.1542 2.1789 2.2033 2.2433 2.3065 2.3942 2.20 2.0101 2.0421 2.0598 2.0710 2.0780 2.0814 2.0917 2.1187 2.1468 2.1744 2.2207 2.2865 2.3688 2.25 1.9886 2.0217 2.0410 2.0536 2.0616 2.0662 2.0695 2.0746 2.1035 2.1341 2.2000 2.2740 2.3554 2.30 1.9227 1.9570 1.9773 1.9911 2.0107 2.0295 2.0483 2.0672 2.0S73 2.1202 2.1860 2.2519 2.3197 2.35 1.8915 1.9323 1.9649 1.9908 2.0137 2.0348 2.0556 2.0763 2.0979 2.1212 2.1893 2.2592 2.3281 2.40 1.S701 1.9132 1.9483 1.9766 2.0018 2.0252 2.0484 2.0774 2.1073 2.1399 2.2066 2.2776 2.3510 2.50 1.8054 1.8417 1.8671 1.8857 1.9169 1.9497 1.9819 2.0134 2.0450 2.0781 2.1420 2.2059 2.2848 2.60 1.7225 1.7525 1.7808 1.8059 1.8296 1.8525 1.8744 1.8950 1.9172 1.9426 1.9927 2.0478 2.1123 2.70 1.7207 1.7443 1.7699 1.7896 1.8098 1.8391 1.8695 1.8985 1.9263 1.9548 2.0109 2.0662 2.1176 2.80 1.7177 1.7464 1.7664 1.7809 1.7945 1.8130 1.8426 1.8709 1.8986 1.9271 1.9824 2.0386 2.0934 2.90 1.6436 1.6637 1.6830 1.7001 1.7154 1.7307 1.7459 1.7614 1.7837 1.8128 1.8694 1.9257 1.9794 3.00 1.6092 1.6314 1.6494.

1.6620 1.6720 1.6811 1.6938 1.7087 1.7240 1.7403 1.7791 1.8316 1.8781 3.10 1.5843 1.6080 1.6280 1.6424 1.6544 1.6653 1.6749 1.6S36 1.6982 1.7152 1.7498 1.7858 1.8227 3.20 1.5830 1.6083 1.6253 1.6364 1.6463 1.6574 1.6691 1.6820 1.6964 1.7132 1.7496 1.7877 1.8230 3.30 1.5910 1.6176 1.6376 1.6506 1.6618 1.6737 1.6857 1.6986 1.7125 1.7286 1.7640 1.8034 1.8413 3.40 1.5609 1.5886 1.6165 1.6378 1.6565 1.6750 1.6922 1.7083 1.7240 1.7403 1.7713 1.8018 1.8306 3.50 1.5239 1.5528 1.5764 1.6004 1.6225 1.6443 1.6646 1.6836 1.7020 1.7206 1.7557 1.7899 1.S224 3.60 1.5295 1.5485 1.5695 1.5868 1.6024 1.6184 1.6338 1.64S5 1.6623 1.6798 1.7154 1.7529 1.7899 3.70 1.5262 1.5430 1.5616 1.5785 1.5947 1.6100 1.6244 1.6386 1.6518 1.6648 1.7017 1.7418 1.7816 3.80 1.5068 1.5245 1.5442 1.5616 1.5787 1.5949' 1.6108 1.6263 1.6412 1.6557 1.6S20 1.7218 1.7639 3.90 1.5041 1.5244 1.5455 1.5647 1.5835 1.6014 1.6191 1.6361 1.6518 1.6668 1.6933 1.7247 1.7666 4.00 1.5293 1.5371 1.5595 1.5797 1.5996 1.6189 1.6380 1.6567 1.6741 1.6907 1.7197 1.7501 1.7876 4.10 1.5314 1.5380 1.5418 1.5532 1.5736 1.5939 1.6140 1.6336 1.6522 1.6700 1.7012 1.7319 1.7672 4.20 1.5170 1.5216 1.5223 1.5256 1.5323 1.5448 1.5679 1.5908 1.6126 1.6338 1.6727 1.7101 1.7456 4.30 1.5235 1.5294 1.5314 1.5352 1.5422 1.5526 1.5646 1.5767 1.5949 1.6172 1.6580 1.6968 1.7335 4.40 1.5252 1.5343 1.5373 1.5413 1.5487 1.5596 1.5722 1.5850 1.5985 1.6126 1.6411 1.6810 1.7189 4.50 1.5317 1.5386 1.5436 1.5476 1.5549 1.5661 1.5794 1.5928 1.6071 1.6223 1.6530 1.6837-1.7130

Calc Number: GEO.HBIP.03.02 Rev Number. 0 Sheet Number: 110 of 349 Date: 08/27/03 4.60 1.5380 1.5458 1.5507 1.5551 1.5618 1.5728 1 1.5863 1.6004 1.6155 1.6316 I.6646 1.6972 1.72X6 4.70 1.5470 1.5563 1.5608 1.5656 1.5711 1.5799 1.5933 1.6079 1.6236 1.64061 1.6758 1.7107 1.7442 4.80 1.5535 1.5609 1.5627 1.5642 1.5649 1.5657 1.5736 1.5864 1.6020 1.6193 1.6553 1.6915 1.72G4 4.90 1.5656 1.5744 1.5776 1.5804 1.5821 1.5842 1.5862 1.5891 1.5927 1.5997 1.6267 1.6605 1.6961 5.00 1.5664 1.5761 1.5814 1.5846 1.5S79 1.5904 1.5935 1.5970 1.6013 1.6065 1.6295 1.6571 1.6812 5.10 1.5682 1.5785 1.5846 1.5896 1.5942 1.5972 1.6006 1.6077 1.6163 1.6256 1.6426 1.6626 1.6863 5.20 1.5693 1.5813 1.5907 1.5980 1.6057 1.6126 1.6194 1.6275 1.6365 1.6459 1.6636 1.6792 1.6951

'5:40' 1.5649 1.5845 t.5992 1.6093 1.6183

'1-6258 1.6337 1.6404 1.6493.

.6591 1.6779 1.69i49 1.7082 5.60 1.5198 1.5417 1.5590 1.5702 1.5797 1.5878 1.5954 1.6026 1.6102 1.6191 1.6380 1.6561 1.6712 5.80 1.4591 1.4819 1.5014 1.5135 1.5230-1.5316 1.5395 1.5468 1.5545 1.5629 1.5808 1.5999 1.6167 6.00 1.4346 1.4500 1.4654 1.4783 1.4886 1.4976 1.5060 1.5138

'1.5217 1.5305 1.5480 1.56%2 1.5907 6.20 1.4087 1.4225 1.4306 1.4326 1.4331 1.4365 1.4456 1.4537 1.4620 1.4709 1.4905 ' 1.5150 1.5407 6.40 1.4233 1.4311 1.4420 1.4512 1.456S 1.4597 1.4602 1.4595 1.4576 1.4551 1.4549 1.4734 1.4951 6.60 1.4060 1.4161 1.4293 1.4385 1.4451 1.4486 1.4501 1.4500 1.4493 1.4473 1.4408 1.4292 1.4375 6.80 1.3977 1.4080 1.4213 1.430R 1.4380 1.4428 1.4452 1.4461 1.4455 1.4443 1.4394 1.4295 1.4176 7.00 1.3910 1.4024 1.4129 1.4211 1.4264 1.4304 1.4333 1.4353 ' 1.4368 1.4379 1.4380 1.4341 1.4276 7.20 1.4089 1.4213 1.4328 1.4402 1.4469 1.4503 1.4539 1.4561 1.4578 1.4591 1.4600 1.4577 1.4530 7.40 1.4487 1.4607 1.4721 1.4813 1.4869 1.4914 1.4950 1.4977 1.5002 1.5021 1.5047 1.5039 1.5009 7.60 1.4576 1.4732 1.4845.

1.4934 1.4989 1.5042 1.5078 1.5110 1.5134 1.5156 1.5196 1.5201 1.5190 7.80 1.4414 1.4547

-1.4665 1.4744 1.4803 1:4854 1.4893 1.4927 1.4955 1:4980 1.5024 1:5042'

'T'5_02 8.00 1.4283 1-4424 1.4537 1.4614 1.4674 1.4726 1.4765 1.4798 1.4829 1.4860 1.4910 1.4941 1.4952 8.50 1.4587 1.4617 1.4609 1.4665 1.4742 1.4796 1.4841 1.4885 1.4925 1.4963 1.5048 1.5111 1.5146 9.00 1.4731 1.4724 1.4741 1.4753 1.4761 1.4824 1.4878 1.4930 1.4981 1.5036 1.5147 1.5234 1.5289 9.50 1.4667 1.4780 1.4813 1.4870 1.4921 1.4933 1.4941 1.4937 1.4938 1.4984 1.5125 1.5229 1.5290 10.0 1 1.4817 1.4893 1.4967 1.5038 1.5089 1.5107 1.5119 1.5123 1.5125 1.5120 1.5183 1.5295 1.5358

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 111 of 349 Date: 08/27/03 Table 9-5SAvrae arnlificaion Iiictors for the nie~i soil jvrofie. ?'V[=7.O.___

Per 0.01 1.7101 1.5542 1.4053 1.2672 1.1531 I.08.73 1.0262 0.9669 0.9117 0U636 0.7886 0.7324 (0.6763 0.03 1.7683 1.6061 1.4504 1.3051 1.1856 1.1135 1.0501 0.9891 0.9321 0.8822 0.8045 0.7466

0. 688 5 0.04 1.6106 1.4405 1.2964 1.1640 1.0545 0.9870 0.9295 0.8746' 0.8237 0.7791 0.7096 0.6581 0.6064

-0:05 1.5404 131713 1.2330 1.0809 0.9749 0.9063 O0.802 0.80-15 0.7541... 0.7124 0.6477

'0.5999 0.5521-0.06 1.4940 1.2589 1.1221 lOGIS8 0.9020 0.8269 0.7722 0.7268 0.6844 0.6472 0.5878 0.5438 0.4999 0.07 1.5073 1.1995 1.0306 0.9251 0.8486 0.7918 0.7395 0.6906 0.6459 0.6074 0.5462 0.5042 0.4621 0.08 1.6177 1.3012 1.0704 0.9271 0.8275 0.7516 0.6958.

0.6494 0.6075 0.5719 0.5124 0.4708 0.4300 0.09 1.6034 1.3451 1.1264 0.9483 0.8354 0.7511 0.6850 0.6295 0.5822 0.5458 0.5001 0.4555 0.4130 0.10 1.6290 1.3287 1.0915 0.9221 0.8087 0.7265 0.6627 0.6073 0.5629 0.5288 0.4814 0.4408 0.3997 0.11 1.6976 1.3809 1.1702 1.0093 0.8856 0.7872 0.7124 0.6503 0.5961 0.5503 0.4739 0.4189 0.3795 0.12 1.9462 1.4978 1.2038 1.0216 0.9000 0.8039 0.7155 0.6508 0.6008 0.5571 0.4825 -0.4238 0.3798 0.13 2.0046 1.5726 1.2937 1.0655 0.8764 0.7671 0.69'78 0.6342 0.5831 0.5426 0.4802 0.43 12 0.3845 0.14 2.1868 1.7778 1.4211 1.1691 0.9764 0.8205 0.7065 0.6396 0.5827 0.5346 0.4692 0.4140 0.3709 0.15 2.0805 1.6550 1.3488 1.1455 1.0146 0.8939 0.7789 0.6832 0.6109 0.5608 0.4918 0.43 16 0.3703 0.16 2.1623 1.6707.

1.3349 1.1822 1.0736 0.9460 0.8213 0.7419 0.6738 0.6100 10.5145 0.4276 0.3707

-f 0.7 211190

7 fl[3 "-T.4530 1.2481I L0792 10.9580 D.8683 0.7966 0.7268 0.'6597 10,5399 :0A~

0.3800 0.18 1.9762 1.8038 1.6173 1.3919 1.2018 1.0701 0.9700 0.8839 0.7989 0.7158 0.5751 0.4696 0.3955 0.19 2.0416 1.6920 1.5008 1.3003 1.1294

-1.0173 0.9293 0.8484 0.7719 0.7095 0.5969 0.5013 0.4351 0.20 2.2138 1.7324 1.4458 1.2493 1.1383 1.0300 0.9241 0.8424 0.7647 0.7073 0.6176 0.5368 0.4493 0.21 2.5145 1.9569 1.6372 1.4394 1.2728 1.1579 1.0583 0.9549 0.8591 0.7815 0.6500 0.5422 0.4740 0.22 2.6506 2.1048 1.7367 1.4623 1.2821 1.1522 1.0612 0.9662 0.8741 0.7922 0.6560 0.5575 0.4893 0.23 2.5883 2.3260 11.9918 1.6693 1.4320 1.2551 1.1289 1.0341 0.9368 0zS546 0.7241 0.5917 0.5181 0.24 2.5095 2.3194 2.0751 1.7612 1.4792 1.2983 1.1580 1.0417 0.9495 10.8815 10.7431 0.6157 0.5424 0.25 2.6223 2.3172 2.0782 1.8314 1.6061 1.3963 1.2363 1.0885 0.9709 0.9007 10.7677 0.6290 0.5535 0.26 2.6173 2.3610 2.1679 1.9839 1.7782 1.5749 1.3931 1.2314 1.0889 0.9786 0.7820 0.6421 0.5538 0.27 2.54317 2.3399 2.2076 2.0454 1.8390 1.6343 1.4737 1.3259 1.1843 1.0615 0.8503 0.6662 0.5629 0.28 2.4888 2.2677 2.1234 1.9901 1.8562 1.7239 1.5806 1.4295 1.2807 1.1456 0.9108 0.7295 0.6172 0.29 2.3 152 2.1663 2.0545 1.9457 1.8260 1.7109 1.5789 1.4337 1.2848 1.1694 0.9462 0.7594 0.6486 0.30 2.1083 2.1104 12.0396 1.8788 1.7551 1.6320 1.5091 1.3822 1.2640 1.1618 0.9759 0.7939 0.6809 0.31 2.0051 2.0323 1.9962 1.9181 1.8488 1.7334 1.6055 1.4754 1.3514 1.2423 1.,0205 0.8208 0.7032 0.32 1.8863 1.8758 1.9158 1.9625 1.9407 1.8603 1.7443 1.6175 1.4883 1.3555 1.1148 0.8733 0.7239 0.33 1.8927 1.7897 1.8877 1.9833 2.0091 1.9561 1.8611 1.7449 1.6145 1.5099 1.2726 0.9970 0.8026 0.34 1.7967 1.6856 1.6854 1.7585 1.7985 1.7715 1.7099 1.6604 1.5926 1.5078 1.2923 1.0291 0.8320 0.35 1.7322 1.6330 1.6081 1.5951 1.6489 1.6699 1.6615 1.6295 1.5728 1.4957 1.2947 1.0485 0.8716 0.36 1.7899 1.6148 1.5424 1.5450 1.5792 1.6051 1.6100 1.5867 1.5355 1.4607 1.2673 1.0519 10.9215 0.37 1.8575 1.6886 1.5877 1.5090 1.4897 1.4980 1.5039 1.4890 1.4.494 1.3914 1.2525 1.1034 0.9771 0.38 1.8349 1.6795 1.5763 1.5006 1.4614 1.4432 1.4409 1.4253 1.3965 1.3554 1.2472 1.1249 1.0020 0.39 1.8859 1.7332 1.6308 1.5445 1.4748 1.4470 1.4252 1.3987 1.3696 1.3342 1.2780 1.1747 1.0519 0.40 1.9201 1.7709 1.6705 1.5860 1.5171 1.4570 1.4138 1.3875 1.3547 1.3180 1.2996 1.2053 1.0906 0.41 1.9554 1.7819 1.6622 1.5781 1.5104 1.4495 1.3989 1.3562 1.3196 1.2930 1.2745 1.2024 1.1061 0.42 2.0114 1.8371 1.6919 1.5582 1.4871 1.4271 1.3832 1.3400 1.2917 1.2549 1.2492 1.1977 1.1151 0.43 2.1105 1.8876 1.1449 1.6122 1.4972 1.4125 1.3686 1.3261 1.2794 1.2358 1.2163 1.1930 1.1267 0.44 2.1610 1.8869 1.7424 1.6160 1.5059 1.4114 1.3320 1.2891 1.2446 1.2042 11.1755 1.1612 1.1057 0.45 2.2179 1.9085 1.7385 1.6192 1.5139 1.4263 1.3506 1.2968 1.2519 1.2136 1.1827 1.1543 1.1010 0.46 2.1743 1.8790 1.7302 1.6247 1.5320 1.4486 1.3737 1.3182 1.2723 1.2330 1.2016 1.1705 1.1113 0.47 2.1347 1.9009 1.7490 1.6306 1.5421 1.4606 1.3866 1.3351 1.2881 1.2479 1.2150 1.1835 1.1244 0.48 2.0386 1.9132 1.7907 1.6583 1.5465 1.4643 1.3963 1.3473 1.2991 1.2579 1.2223 1.1900 1.1317 0.49 1.9891 1.9038 1.7947 1.6617 1.5499 1.4582 1.4019 1.3519 1.3029 1.2604 1.2222 1.1893 1.1324 0.50 1.9544 1.8690 1.7731 1.6475 1.5297 1.4675 1.4110 1.3597 1.3098 1.2658 1.2249 1.1918 1.1367 0.51 1.8975 1.8334 1.7398 1.6243 1.5360 1.4730 1.4164 1.3643 1.3134 1.2686 1.2257 1.1930 1.1396 0.52 1.8411 1.7952 1.7081 1.6104 1.5404 1.4776 1.4208 1.686 1.31-76 1.2-723 1.2279 1.1951 1.1436 0.53 1.8293 1.7542 1.6856 1.6128 1.5438 1.4820 1.4261 1.3740 1.3226 1.2768 1.2308 1.1983 1.1479 0.54 1.8264 1.7531 1.6860 1.6288 1.5692 1.4969 1.4330 1.3811 1.3297 1.2835 11.2354 1.2022 1.1528 0.5 5 1.8222 1.7515 1.7118 1.6755 1.6145 1.5414 1.4638 1.3899 1.3381 1.2910 1.2407 1.2064 1.1578

  • 0.56 1.8180 1.7505 1.7308 1.6951 1.6356 1.5640 1.4873 1.4084 1.3473 1.2992 1.2463 1.2109 1.1629 0.57 1.8151 1.7518 1.7345 1.7009 1.6466 1.6047 1.5413 1.4630 1.3901 1.3284 1.2516 1.2153 1.1678 0.58 1.8138 1.7552 1.7326 1.7100 1.6914 1.6497 1.5852 1.5072 1.4329 1.3683 1.2736 1.2192-1.1727 0.60 1.7907 1.7411 1.7176 1.7166 1.7142 1.6852 1.6204 1.5418 1.4696 1.4030 1.3135 1.2631 1.2023 0.62 1.7605 1.7181 1.6901 1.6979 1.7052 1.6874 1.6412 1.5703 1.4992 1.4333 1.3749 1.3268 1.2703 0.64 1.6813 1.6428 1.6065 1.6228 1.6402 11.6469 1.6259 1.5732 1.5095 1.4428 1.3727 1.3282 1.2774 1 0.66J 1.6913 1.6467

-1.6215 1.6119 1.6263 11.6273 1.6116 1.56i474 11.5042 1.4403 I1.3770 1.3359 11.2901

Cale Number: GEO. HB IPO.0302 Rev Number: 0 Sheet Number: 1 12 of '349

______D ate: 0 8/2 7/03 0.68 1.7013 1.6576 )1.6320 11.6075 1.5902 11.5926 ]1 1.5767 11.538M 1.4940 1.4499 11.3865 ) 1.3502 ]

1.3095 0.70 1.7026 1.6602 1.6353 11.6103 1.5886 1.5706 j1.5517 1.5341 1.5004 1.4604 11.4003 11.369 t 1.3327 0.72 1.69-70 1.6575 1.~6344 1.6103 1.5889 1.5713 J1.5514 J1.5254 1.4966 1.4617 1.4171 11.3895 1.3560 0.74 1.6876 1.6516 1.6312 1.6093 1.5898 1.5739 I1.5562

-1.5324 1.5027 1.4725 1.4354 11.4101 J1.3787 0.76 1.6778 1.6442 1.6258 1.6067 j1.5900 1.5769 1.5623 1.5415 1.5151 )1.4911 1.4626 11.4346 41.4037 0.780 1.6759 1.6291 1.6053 1.5815 j1.5521 1.5353 1.5211 1.5478 1.4398 1.4556 1.45902 1.4378 1.44181 0.78 1.6759 1.6297 1.605 1.5885 J1.5749 1.564853 5 1.521 68 1.5098 1.426 1.475 502 1.4768 11.44113 0.82 1.7464 1.6882 1.47 1.6029I 1.5643 1.5501 1.5312 1.,5059 1.4759 ]I1:47r0' 1A-.31i7 1i433N8.

T..4215 0.84 1.7738 1.7106 1.6626 1.6100 1.5703 1.5476 1.5274 1 5029

.1.4754 11.4506 1.4461 1.4531 1.4465 0.86 1.8887 1.7871 1.7308 1.6808 1.6251 1.5743 1.5389 1.5188 1.4955 1.4737 1.4553 1.4518 1.4459.

0.88 2.0296 1.9342 1.8514 1.7815 11.7277 1.6780 1.6355 1.5960 1.5579 1.5270 1.4902 1.4622 1.4438 0.90 2.0282 1.9445 1.8698 1.7932 1.7205 1.6683 1.6298 1.5937 1.5640 1.5429 1.5077 1.4800 1.4525 0.92 2.0297 1.9570 1.8904 1.8185 1.7475 1.6881 1.6429 1.6077 1.5813 1.5611 1.5267 1.4996 1.4729 0.94 2.0371 1.9690 1.9102 1.8435 1.7755 1.7164 1.6689 1.6304 1.6018 1.5806 -11.5467 11.5194 1.4939 0.96 2.0906 1.9896 1.9300 1.8685 1.8040 1.7463 1.6980 1.6576 1.6266 1.6027 11.56R7 1.5406 1.5160 0.98 2.1356 2.0277 1.9560 1.8905 1.8296 1.7738 1.7258 1.6845 1.6519 1.6267 1.5900 1.5611 1.5368 1.00 2.1606 2.0556 1.9768 1.9052

.1.8397 1.7864 1.7397 1.6985 1.6652 1.6393 1.6006 1.5708 1.5467 1.05 2.2138 2.1203 2.0409 1.9597 1.8766 1.8175 11.7747 11.7352 1.7020 1.6757 1.6351 1.6038 1.5781 1.10

-2.3398 2.2476 2.1578 2.0620 1.9709.

1.8975 1.8363.. 1.796.

1.7556 1.7283 1.6849 1.6497 11.6 179 1.15 2.5284 2.4204 2.3092 2.1958 2.0972 2.0084 1.9355~ 1.8687 1.8048 1.75899'-

1.7067 1.66S F-1'631 8 1.20 2.6592 2.5729 2.4969 2.4132 2.3134 2.2146 2.1 207 2.0316 11.9575 11.8878 11.8006 11.7279 11.6740 1.25 2.6368 2.6056 2.5606 2.4918 2.4062 2.3192 2.2353 2.1505 2.0649 1.9826 11.8823 1.8080 11.7519 1.30 2.5993 2.5983 2.5809 2.5370 2.4702 2.3959 2.3204 2.2417 2.1620 2.0845 1.9699 1.9727 1.811 11 1.35 2.6156 2.6335 2.6239 2.5870 j2.5284 12.4614 2.3919 2.3182 2.2441 2.1793 2.0660 1.9672 1.8944 1.40 2.5609 2.5825 2.5786 2.5506 2.5035 2.4487 2.3904 2.3265 2.2650 2.2048 2.1058 2.017 1.9390 1.45 2.4153 2.4427 2.4553 2.4434 2.4092 2.3663 2.3228 2.2801 2.2370 2.1931 2.1078 2.0213 1.9414 1.50 2.3265 2.3710 2.3982 2.4094 2.4024 2.3812 2.3537 2.3178 2.2771 2.2345 2.1488 2.0601 1.9776 1.55 2.3476 2.3972 2.4286 2.4425 2.4407 2.4400 2.4278 2.3973 12.3525 2.2992 2.1997

-2.1077 2.0216 1.60 2.3293 2.4106 2.4688 2.5105 2.5348 2.5475 2.5530 2.5311 2.4919 2.4434 12.3095 2.1627 2.0704 1.65 2.2935 2.3716 2.4335 2.4983 2.5685 2.6107 2.6242 2.6112 2.5938 2.5557 12.4378 2.2884 2.2043 1.70 2.1798 2.2354 2.2955 2.3926 2.4782 2.5436 2.5839 2.5940 2.5867 2.5 586 12.4798 2.3696

-2.2786 1.75 2.1193 2.1743 2.2190 2.2560 2.3120 2.3617 2.4218 2.4574 2.4725 2.4666 12.4275 2.4061 I2.3506 1.80 2.0820 2.1551 2.2109 2.2581 2.3029 2.3440 12.4001 2.4439 2.4927 2.5270 12.5486 2.5103 12.4310 1.85 2.0764 2.1509 2.2056 2.2508 2.2923

'2.3400 2.3972 2.4431 2.4804 12.5190 12.5448 2.5137 12.4647 1.90 2.0695 2.1478 2.2051 2.2527 2.2972 12.3526 2.4115 2.4591 12.4958 2.5244 12.5542 2.5503 2.5093 1.95 2.0398 2.1206 2.1800 2.2293 2.2763 2.3238 2.3825 2.4307 12.4688 2.4976 2.5378 2.5427 2.5081 2.00 1.9990 2.0821 2.1440 2.1959 2.2470 2.2973 2.3431 2.3824 12.4202 2.4539 2.4974 12.5171 2.5200 2.05 1.9504 2.0405 2.1099 2.1685 2.2248 2.2777 2.3259 2.3678 12.4042 2.4336 2.4871 12.5341 2.5543 2.10 1.8830 1.9718 2.0413 2.1018 2.1594 2.2135 2.2632 2.3069

-2.3457 2.3778 2.4458 12.5150 2.5409 2.15 1.8509 1.9221 1.9899 2.0454 2.0967 2.1441 2.1950 2.2409 2.2823 2.3174 2.4102 2.4838 12.5140 2.20 1.8140 1.8688 1.9367.

1.9942 2.0471 2.0959 2.1403 2.1800 2.2169 2.2604 2.3601 2.4376 2.4743 2.25 1.7707 1.8282 1.8751 1.9344 1.9888 2.0390 12.0849 12.1264 2.1649 2.2123 2.2968 2.3726 2.4413 2.30 1.7359 !1.7857 1.8286 1.8718 1.9281 1.9801 2.0279 2.0716 2.1157 2.1635 2.2514 2.3132 2.3700

'2.35 1.7215 1.7471 1.7889 1.8253 1.8678 1.9223 1.9778 2.0323 2.0840 2.1299 2.2035 2.2760 2.3205 2.40 1.7094 1.7380 1.7589 1.7891 1.8276 11.8828 1.9450 2.0005 2.0529 2.0996 2.1732 2.2406 2.2939 2.50 1.6905 1.7248 1.7507 1.7728 1.8041 1.8547 1.9002 1.9408 1.9909 12.0396 2.1205 12.1903 12.2446 2.60 1.6648 1.7048 1.7360 1.7626 1.7898 1.8253 1.8730 1.9157 1.9567 11.9995 2.0928 12.1668 12.2207 2.70 1.5952 1.63 83 1.6729 1.7017 1.7302 1.7570 1.7911 1.8333 1.8739 11.9120 1.9963 12.0738 12.1319 2.80 1.5484 1.5811 1.6063 1.6278 1.6490 1.6685 1.6905 1.7169 11.7566 1.7940 1.8592 1.9386 2.0029 2.90 1.5439 1.5827 11.6114 1.6352 1.6583 1.6804 1.7002 1.7167 1.7313 1.7603 1.8118 1.8584 1.9231 3.00 1.5575 1.5908 1.6147 1.6317 1.6522 1.6766 1.6991 1.7188 1.7367 1.7524 11.8056 1.8590 1.9196 3.10 1.5869 1.6251 1.6539 1.6757 1.6916 11.7034 1.7126 1.7210 1.7376 1.7566 1.8027 1.8639 1.9160 3.20 1.5372 1.5798 1.6125 1.6378 1.6581 11.6742 1.6872 1.6990 1.71 10 1.7225 1.7444 1.8014 1.8548 3.30 1.5116 1.5596 1.5962 1.6255 1.6500 1.6700 1.6867 1.7019 1.7169 1.7313 1.7572 1.8058 1.8618 3.40 1.4489.

1.4999 1.5379 1.5688 1.5959.

1.6200 1.6412 1.6598 1.6767 1.6913 1.7153 1.7453 1.8039 3.50 1.3983 1.4531 I1.4935 1.5264 1.5551 1.5798 1.6010 1.6198 1.6370 1.6512.

1.6788 1.7111 1.7560 3.60 1.3768 1.4232 1.4611 1.4931 1.5214 1.5463 1.5685 1.5892 1.6087 1.6296 1.6673 1.7010 1.7269, 3.70 1.3376 1.3833 1.4232 1.4579 1.4893 1.5180 1.5439 1.5672 1.5880 1.6056 11.6343 1.6632 1.6886 3.80 1.3252 1.3688 1.4033 1.4326 1.4599 11.4875 1.5138 1.5392 1.5631 1.5838 11.6177 1.6457 (1.6657 3.90 123428 1.3686 1.4043 1.4372 1.4689 1.4986 1.5261 1.5524 1.5771 1.5988 11.6355 1.6670 1.6899 4.00 1.3570 1.3830 1.4061 1.4390 1.4722 1.5034 1.5321 1.5592 1.5847 1.6073 1.6466 1.6815 1.7073 4.10 1.3444 1.3747 1.4001 1.4230 1.4540 1.4844 1.5117 1.5372 1.5613 1.5834 1.6241 1.6615 1.6896 4.20 1.3007 1.3334 1.3605 11.3850 1.4073 1.4380 1.4655 1.4908 1.5144 11.5354 1.5738 1.6115 1.6409 4.30 1.2819 1.3010 1.3231 1.3463 1.3680 1.3960 1.4237 1.4492 1.4728 1.4938 1.5316 1.5692 1.5992 4.40 1.2855_

1.3027 1.3196 11.3352 1 1.3526 11.3761 1.4007 1.4223 1.4412 11.4623 1.5003 1.5382 1.5692

Calc Number: GEO.HB[P.03.02 Rev Number: 0 Sheet Number: 1 13 of 349 Date: 0S827/03 I

4.50 1.2988 1.3167 1.3335 1.3495 1.3622 1.3747 1.4037 1.4306 1.4548 1.4754 1.5094 1.5404 I1.5647 4.60 1.3110 1.3289 1.3463 1.3623 1.3752 1.3S91 1.4060 1.4343 1.4599 1.4821 1.5189 1.5527 1.5791 4.70 1.3179 1.3417 1.3645 1.3S62 1.4038 1.4182 1.4300 1.4394 1.4521 1.4639 1.4844 1.5158 1.5445 4.80 1.2973 1.3214 1.3445 1.3671 1.3S61 1.4021 1.4156 1.4265 1.4361 1.4437 1.4588 1.4764 1.4895 4.90 1.2634 1.2878 1.3108 1.3341 1.3544 1.3721 1.3877 1.4008 1.4129 1.4230 1.4382 1.4519 1.4607 5.00 1.2365 1.2594 1.2823 1.3062 1.3280 1.3475 1.3651 1.3809 1.3956 1.4081 1.4300 1.4484 1.4610 5.10 1.2158 1.2383 1.2596

-1.2S32 1.3059 1.3270 1.3467 1.3648 1.3822 1.3971 1.4208 1.4419 1.4537 5.20 1.2027 1.2263 1.2475 1.2711 1.2942 1.3-164 1.3378 1.3583

-.37S1 13'954-' --4273 -- 1.4491 1.-4693S 5.40 1.2545 1.2723 1.2929 1.3155 1.3372 1.3581 1.3786 1.3987 1.4189 1.4367 1.4634 1.4838 1.5022 5.60 1.2570 1.2713 1.2862 1.3022 1.3161 1.3295 1.3458 1.3685 1.3916 1.4125 1.4442 1.4694 1.4929 5.80 1.2815 1.2948 1.3099 1.3263 1.3411 1.3550 1.3691 1.3832 1.3988 1.4138 1.4382 1.4590 1.4789 6.00 1.2205 1.2219 1.2261 1.2337 1.2480 1.2617 1.2756 1.2896 1.3054 1.3205 1.3450 1.3657 1.3857 6.20 1.1849 1.1854 1.1841 1.1844 1.1882 1.1935 1.2010 1.2151 1.2298 1.2438 1.2672 1.2881 1.3082 6.40 1.1806 1.1727 1.1649 1.1662 1.1717 1.1753 1.1777 1.1829 1.1909 1.1987 1.2171 1.2323 1.2476 6.60 L.1842 1.1799 1.1868 1.1933 1.1979 1.2034

.. 1.2074 1.2106 1.2132 1.2147 1.2127 1.2201 1.2292 6.80 1.1930 1.2009 1.2104 1.2182 1.2242 1.2276 1.2299 1.2321 1.2344 1.2363 1.2375 1.2417 1.2524 7.00 1.2150 1.2272 1.2384 1.2484 1.2561 1.2612 1.2648 1.2682 1.2715 1.2742 1.2773 1.2835 1.2962 7.20 1.2480 1.2526 1.2611 1.2722 1.2821 1.2887 1.2936 1.2978 1.3019 1.3054 1.3099 1 1.3177 1.3321 7.40 T 1.2792 1.2842 1 1.2893 [1-1.2913-.

1.2954 1 1.3033 1 1.3093 I 1.3139

_ 1.3186

_ 1.3222 1 1.3278 r 1.3369 1 1.3523 7.60 1.3211 1.3274 1.3319 1.3343 1.3362 1.3373 1.3381 1.3395 1.3420 1.3461

.3'525 ' 1.3627 1.37 7.80 1.3263 1.3320 1.-3374 1.3401 1.3424 1.3436 1.3454 1.34 74 1.3506 1.3539 1.3603 1.3690 1.3795 8.00 1.2980 1.3037 1.3092 1.3119 1.3145 1.3163 1.3185 1.3211 1.3249 1.3289

-1.3385 1.3548 1.3711 8.50 1.2384 1.2383 1.2398 1.2393 1.2421 1.2462 1.2519 1.2590 1.2672 1.2746 1.2883 1.3034 1.31X0 9.00 1.2300 -

1.2229 1.2203 1.2164 1.2185 1.2234 1.2301 1.2377 1.2464 1.2552 1.2705 1.2876 1.3041 9.50 1.3058 1.3007 _1.2993 1.2979 1.2963 1.2957 _ 1.2971 _1.3003 1.3053 1.3105 1.3211 13403 1.3599 10.00 1 1.3233 I 1.3204 109463 1.3181 1.3172 1 1.3179 I 1.3197 1.3233 11.3283 1.3338 1.3448 1.3604 1.3789 A -

- Zzi;e

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 1 14 of 349 Date: 08/27/03 Table 9-6. Avr~

ialifiat ion fiactors for the mne s~pil profile. NM17.8.

Per (see)j UR~02 03

... 9A

.g 06

.g 08 0.92 1.01 1.2s, 1.4c 1.6'g 0.0.1 1.6554 1.4-777 1.3110 1.1554 1.0685 1.0Ml11 0.973R 0.9356

0. 9107 0.8756 0.7883 0.6932 10.6084 0.03 1.7049 1.5146 1.3407 1.1760 1.0851 11.0341 0.9849 0.9458--
0. 9-209 0.8858 0.7974 0.70019 0.6149 0.04 1.4406 1.2637 1.1104 0.9679 0.8912 0.8476 0.8071 0.7744 0.7532 0.7241 0.6515 0.5725 0.5022 0.05 1.3078 1.1215 0.9822 0.8430 0.7773 0.7347 0.6982 0.6700 0.6514 0.6264 10.5635 0.4951 0.4341 0.,06 1.2741 1;030~1-0:9019 0.790?1 iS!177' 0.6774, i643 0.152 0.5968.0:O.5736 0.5158 --0:4529 -

07 0.07 1.2965 0.9983 0.8692 0.7453 0.6619 0.6199 0.5875 0.5624 0.5458 0.5249 0.4721 0.4144 0.3631 0.08 1.4177 1.0475 0.8870 0.7458 0.6457 0.593 0.5500 0.525-7 10.5096 0.4914 0.4433 0.3898 0.3418 0.09 1.4686 1.0910 0.8955 0.7599 0.6588 0.6003 0.5594 0.5262 10.5038 0.4811 0.4297 0.3758 0.3286 0.10 1.5433 1.2275 0.9940 0.8369 0.7131 0.6346 0.5802 0.5419 10.5092 0.4814 0.4274 10.3721 0.3244 0.11 1.6230 1.2744 1.0475 0.8330 0.7184 0.6275 0.5765 0.5311 10.4864 10.4598 0.4133 10.3620 0.3164 0.12 1.6635 1.3145 1.0741 0.8996 0.7708 0.6671 0.5975 0.5399 0.4958 0.4615 10.4059 10.3550 0.310O8 0.13 1.7643 1.5146 1.2010 0.9120 0.7394 0.6613 0.5978 0.5416 0.4948 0.4556 0.4005 10.3491 0.3058 0.14 1.9082 1.4922 1.1963 0.9475 0.7921 0.6850 0.5994 0.5347 0.4744 0.4425 0.3865 10.3379 0 02980 0.15 1.8602 1.5537 1.2630 1.0298 0.8497 0.7318 10.6400 0.5611 0.4846 0.4404 0.3811 0.3330 0.2921 0.16 1.9816 1.6192 1.3815 1.1371 0.9461 0.8050 0.6962 0.6063 0.5345 0.4819 0.4080 0.3508 0.3041 0.17.

2.1221 1.7195 1.3901 1.1591 0.9852 0.8374 0.7173 0.6365 0.5701 0.5169 0.4279 0.3609 -0.3116

--.5 1.9088 1.6747 -1.3769 1.1269 -0.95RI 0.8412 0.1536 0.6792 10.61-4T-'Y.51 0.4576 0.382b0;'

0.3 147 0.19 1.9217 1.5777 1.3753

- 1.1734

.1.0309 0.9153 0.8143 0.7247 0.6403 0.5770 0.4821 0.402-6 10.3388 0.'20 2.0373 1.5904 1.4033 1.2672 1.1206 0.9937 0.8871 0.7954 0.7154 0.6484 0.5361 0.4445 10.3759 0.21 2.2719 1.6944 1.4330 1.2571 1.1274 11.0248 0.9330 0.8479 0.7609 0.6882 0.5714 0.4731 10.3985 0.22 2.3795 1.7846 1.5100 1.3337 1.1968 1.0788 0.9719 0.8846 0.7979 0.7255 0.6058 0.5024 0.4194 0.23 2.4166 1.9450 1.5336 1.3557 1.2163 1.1048 1.0021 10.9032 0.8097 0.7437 0.6285 0.5259 0.4369 0.24 2.2557 2.1074 1.6669 1.4042 1.2378 1.1223 1.0213 10.9256 0.8437 0.7834 0.6628 0.556R 0.4689 0.25 2.2817 2.1158 1.8273 1.5197 1.3056 1.1837 1.0789 10.9761 10.8744 0.8077 0.6870 0.5801 0.4901 0.26 2.3702 2.1692 1.9182 1.6045 1.3444 1.2073 1.0870 0.9746 0.8790 0.8161 10.6960 0.5844 0.4914 0.27 2.4270 2.1947 1.9466 1.6457 1.3944 1.2470 1.1290 1.0196 0.9107 0.8226 0.6941 0.5848 0.4978 0.28 2.4409 2.2613 1.9985 1.7221 1.4741 1.3168 1.1796 1.0535 0.9339 0.8458 0.7202 0.6052 0.5120 0.29 2.2750 2.1613 1.9452 1.7130 1.5147 1.3584 1.2045 1.0718 0.9566 0.8694 0.7433 0.6257 0.5298 0.30 2.1607 2.1814 1.9669 1.7206 1.5726 11.4321 1.2967 1.1514 1.0165 0.9216 0.7853 0.6633 0.5632 0.31 1.9354 1.9474 1.8250 1.6888 1.5763 1.4472 1.2993 1.1592 11.0400 0.9461 0.8067 0.6834 0.5834 0.32 1.8812 1.8387 1.7716 1.6690 1.5569 1.4310 1.2962 1.1703 i1.0540 10.9625 0.8258 0.7042 10.6045 0.33 1.8768 1.8153 1.7342 1.6189 1.5114 1.4181 1.2942 1.16t0 1.0464 0.9624 0.8275 0.7041 10.6064 0.34 1.8513 1.7910 1.6920 1.6053 1.5608 1.4753 1.3518 1.2278 1.0955

.1.0030 0.8670 0.7441 9.6416 0.35 1.8239 1.7785 1.6964 1.6022 1.5658 1.5013 1.3841 1.2486 1.1335 1.0499 0.9122 0.841064 0.36 1.7503 1.7000 1.6318 1.5393 1.4550 1.4007 1.3354 1.2521 1.1554 1.0729 0.9362 10862 J 0.6975.

0.37 1.7527 1.6408 1.5704 1.5010 1.4478 11.4035 1.3714 11.2951 11.1913 1.1079 10.9789 086 075 0.38 1.7504 1.6733 1.5928 1.5061 1.4642 1.4348 1.3972 11.3395 11.2647 1.1907 11.0490 0.9076 I0.7903 0.39 1.7941 1.6351 1.5829 1.5097 1.4738 1.4520 1.4231 11.3914 11.3190 11.2269 11.0873 0.9493 I0.8392 0.40 1.7698 1.5687 1.4721 1.4183 1.3914 1.3781 1.3595 11.3398 1.3023 1.2347 11.1070 0.9746 -0.8609 0.41 1.8436 1.5651 1.4213 1.3648 1.3380 1.3325 1.3419 1.3454 1.3189 1.2732 1.1643 1.0243 0.9011 0.42 1.9322 1.5800 11.3829 1.3117 1.2886 1.3004 1.3194 1.3263 1.3342 1.3134 1.2100 1.0699 0.9403 0.43 1.9735 1.5834 11.3604 1.2328 1.2193 1.2229 1.2376 1.2627 1.2857 1.2749 1.1830 11.0515 0.9275 0.44 2.0111 1.6670 1.4377 1.2579 11.2037 1.2003 1.2097 1.2232 1.2530 1.2564 1.1941 1.0785 0.9555 0.45 2.1604 1.7979 1.5331 1.3357 1.1825 1.1317 1.1218 1.1427 1.1750 1.1880 1.1480 11.0539 0o.9433 0.46 2.2252 1.8706 1.5878 1.3805 1.2294 1.1443 1.1042 1.0876 1.1230 1.1524 1.1366 11.0452 10.9341 0.47 2.2561 1.9096 1.6041 1.3845 1.2277 1.1436 1.0981 1.0820 1.0889 1.0885 11.0938 1.0285 10.9322 0.48 2.2293 1.9534 1.6696 1.4544 1.2919 1.1759 1.1075 1.0758 1.0785 1.0739 1.0635 1.0021

.0.9082 0.49 2.1766 1.9582 1.6844 1.4776-1.3216 1.2079 1.1180 1.0634 1.0680 1.0662 1.0418 0.9838 0.9034 0.50 2.0871 1.9070 11.6860 11.4950 1.3374 11.2235 1.1410 11.0833 1.0773 1.0731 1.0503 0.9821 0.8822 0.51 2.0036 1.9199 1.7317 1.5467 1.3860

-1.2634 1.1563 1.0973 1.0872 1.0830 1.0594 0.9895 0.8876 0.52 1.9453 1.8986 1.7374 1.5718 1.4128 1.2839 1.1792 1.0879 11.0690 1.0634 1.0368 0.9687 0.507 0.53 1.9077 1.8739 1.7698 1.6310 1.4789 1.3473 1.2272 1.1307 11.0911 1.0688 11.0167 0.9532 1080 0.54 1.8605 1.8836 1.8298 1.6811 1.5187 1.3817 1.2607 1.1639 1.1287 1.1070 11.0523 0.9682 1084 0.55 1.8035 1.8863 1.8346 1.6892 1.5387 1.4026 1.2780 1.1838 1.1451 1.1174 1.0608 0.9668 10.8641 0O.56 1.7973 1.8782 1.8485 1.7390 1.5877 1.4497 1.3257 1.2380 1.1790 1.1361 1.0792 0.9783 [0.859 0.57 1.7391 1.8282 11.8434 1.7408 1.5939 11.4518 11.3448 11.2596 1.2031 1.1550 1.0796 0.9761 10.8436 0.58 1.7098 1.8118 1.8285 1.7469 1.6501 1.5243 1.3895 1.2832 1.2280 1.1808 1.1011 0.9991 1098 0.60 1.6679 1.7477 1.8337 1.8282 1.7402 1.6096 1.4837 1.3703 1.2867 1.2119 1.1087 1.0143 10.9002 0.62 1.6047 1.6763 1.7394 1.7351 1.7283 1.6734 1.5683 1.4428 1.3440 1.2572 1.1405 1.0163 10.8720 0.64 1.4782 1.5691 1.6395 1.7078 1.7474 1.7116 1.6181 1.4992 1.4061 1.3262 1.1951 1.03 0.8850 0.66 1.4'21 1 1.5247 1.6086 11.6936 1.7405 1.7151 1.6418 1.5466 1.4698 1.4049 1.2902 1.136 924 0.68 1.5219 1.5401 1.5854 11.6620 1.7091 1.6985 1.6356 1.5588 1.5018 1.4461 1.3368 1.186 1.0029

Caic Niumber: GEO.H{BIP.0-3.02 Rev Number: 0 Sheet Number: 11 5 of' 349

~~ ~~Date:

08/27/03 0.70 1.6566 1.6279 1.6305 1.6190 1,6465 1.6438 1.6167 1.5727 1.5358 j1.4908 11.3690 1.19700 1.0041 0.72 1.6527 1.6423 1.6294 1jj.605 1.6265 1.6062 1.5683 1.5380 J1.4944 1.3755 1.2114 I.0180ii 0.74 1.6571 1.6579 1.6483 1.62 13j~.6045.

1.5885 1.5544 1.5260 j1.4838 1.3699 1.2126 1.0349 0.76 1.6529 1.6632 1.6617 1.6413 1.62371 1.6027 1.5716 1.5330 1.5088 I1.4770 1.3787 1.2382 1.0713 0.78 1.6176 1.6330 1.6389 1.6210 1.6047 1.5848 1.5549 1.5172 1.4923 1.4604 1.3918 1.2871 1.1174

0. 80 1.5938 1.5708 1.5839 1.5705 1.5602 1.5463 1.5226 1,4946 1.4829 1.4706 1.4219 1.3179 1.1488 0.82 1.6-118 1.5650 1.35558 1.5538 1.5543 1.5463 1.5285 1.5053 1.5010 1.4916

[,4473 1.3447 1.1762 0.84 1.737!3 1-i.6452 1.5948 1.5447 1.5214 1.5033 1.4911 1.4731 1.4751 1.4730.1.43~62 -

.49 215 0.86 1.7805 1.6719 1.6167 1.5589 1.5083 1.4872 1.4713 1.4603 1.4731 1.4756 1.4433 1.3542 1.2139 0.88 1.8098 1.6890 1.6274 1.5677 1.5176 1.4720 1.4445 1.4379 1.4520 1.4555 1.4272 1.3429 1.2073 0.90 1.8526 1.7312 1.6469 1.5825 1.5297 1.4814 1.4381 1.4174 1.4314 1.4351 1.4091 1.3292 1.2004 0.92 1.8969 1.7718 1.6764 1.5915 1.5347 1.4831 1.4367 1.4088 1.4091 1.4133 1.3899 1.3161 117 0.4 1.9617 1.8428 1.7505 1.6457 1.5791 1.5228 1.4744 1.4433 1.4324 1.4176 1.3-776 1.3250 1.43 0.96 1.9802 1.8627 1.7751 1.6711 1.5966 1.5433 1.5001 1.4693 1.4585 1.4448 11.4040 1.3479 1.2646 0.98 2.0119 1.8822 1.7964 1.6865 1.6113 1.5566 1.5143 1.4833 1.4716 1.4576 11.4159 1.3578 1.2735 1.00 2.0390 1.9030 1.8063 1.6965 1.6099 1.5536 1.5103 1.4785 1.4647 1.4493 11.4058 1.3463 1.2624 1.-05 2.2544 2.0738 1.9419 1.7961 1.6816 1.5931 1.5366 1.5022 1.4841 1.4642 11.4172 1.3579 1.280 1.10 2.4641 2.2995 2.1512 1.9663 1.8188 1.7031 1.6082 1.5351 1.5076 1.4785 11.4107 1.3344 1.2611 1.15 2.572 5. 2.4088 2.27.6~ 1 2.1105 1.9639 -.,U35 1.7424 1.6741 4J.6294 1.5853 1.4938 1.3990 1.3216 1.20 2.5977 2.4999 2.3954 2.2462 2.1219 2.0216 1.9339 1.8571 1.7983 1.7371

-'.69 1.4638 1.341'9 1.25 2.6361 2.5525 2.4339 2.2576 2.1501 2.0696 1.9928 1.9224 1.8676 1.8106 1.6869 1.5425 1.4017 1.30 2.5687 2.5594 2.4875 2.3606 2.2329 2.1295 2.0535 1.9887 1.9383 1.8847 1.7665 1.6252 1.4820 1.35 2.6043 2.6760 2.6702 2.5875 2.4773 2.3578 2.2382 2.1444 2.0790 2.0113 1.8675 1.7080 1.5466 1.40 2.5978 2.6831 2.7247 2.6804 2.5922 2.4847 2.3638 2.2374 2.144-7 2.0586 1.9004 1.7341 I1.5656 1.45 2.5421 2.6652 2.7228 2.7005 2.6294 2.5536 2.4688 2.3709 2.2738 2.1663 1.9553 1.7653 11.5301 1.50 2.4217 2.5452 2.6067 2.5985 2.5617 2.5152 2.4441 12.3551 2.2656 2.1836 2.0135 1.8201 11.6220 1.55 2.2873 2.3879 2.4585 2.4942 2.4918 2.4667 2.4338 2.3800 2.3204 2.2462 2.0889 1.8984 1.6984 1.60 2.2558 2.3578 2.4404 2.5203 2.5653 2.5719 2.5459 2.4913 2.4-217 2.3315 2.1576 1.9661 1.7624 1.65 2.3012

'2.4155 2.5422 2.6406 2.7014 2.7364 2.7267 2.6793 2.6099 2.5116 2.2787 2.0410 1.8324 1.70 2.2534 2.3776 2.5088 2.6151 2.7059 2.7521 2.7539 2.7169 2.6545 2.5604 2.3138 2.0977 1.9044 1.75 2.1490 2.2723 2.3925 2.5066 2.6077 2.6652 2.6805 2.6569 2.6121 2.5412 2.3536 2.1524 1.9517 1.80 2.0760 i2.2124 12.3300 2.4339 2.5310 2.6025 2.6430 2.6479 2.6297 2S5 871 2.4362 2.2288 2.0320 1.85 2.0749 2.1796 12.2777 2.3938 2.4910 2.5686,2.6156 2.6326 2.6237 2.5855 2.4707 2.2984 2.1015 1.90 2.0754 2.1904 i2.2975 2.4060 2.4978 2.5686 2.6251 2.6555 2.6614 2.6379 2.5271 2.3509 2.1810 1.95 2.0094 2.1323 2.2422 2.3547 2.4503 2.5232 2.5748 2.6043 2.6128 2.5935 2.5045 2.3920 2.2416 2.00 1.2752 1.9719 2.0695 2.1769 2.2711 2.3460 2.4039 2.4436 12.4645 2.4602 2.4504 2.3877 2.2693 2.05 1.8144 1.9151 2.0096 2.1135 2.2093 2.2911 2.3703 2.4402 2.4892 2.5150 2.5032 2.4291 2.3013 2.10 1.8345 1.9268 2.0150 2.1070 2.1887 2.2784 2.3590 2.4278 2.4809-2.5131 2.5226 2.4438 12.2942 2.15 1.7990 1.8942 1.9791 2.0762 2.1602 2.2313 2.2950 2.3507 2.3947 2.4210 2.4266 2.3868 2.3300 2.20 1.7529 1.8404 1.9344 2.0372 2.1244 2.1960 2.2574 2.3087 2.3474 2.3728 12.4026 2.4110 2.3814 2.25 1.7132 1.8037 1.8843 1.9914 12.0833 2.1589 2.2235 2.2778 2.3199 2.3488 12.4011 2.4320 2.4042 2.30 1.6482 1.7392 1.2203 1.9146 2.0093 2.0877 2.1550 2.2122 27.2577 2.2903 2.3699 2.4009 2.3833 2.35 1.6013 1.6923 1.7706 1.8544 1.9408 2.0224 2.0933 2.1547 2.2045 2.2514 2.3332 2.3655 2.3461 2.40 1.5606 1.6421 1.7199 1.8064 1.8870 1.9613 2.0372 2:-1028 2.1566 2.2071 2.2892 2.3257 2.3233 2.50 1.5114 1.5641 1.6171 1.6945 1.7732 1.8519 1.9279 1.9946 2.0507 2.0943 2.1707 2.2289 12.2524 2.60 1.5546 1.6052 1.6595 1.7246 1.7918 1.8713 1.9446 2.0111 2.0684 2.1163 2.1974 2.2607 12.3053 2.70 1.4709 1.5273 11.5797 1.6424 1.7051 11.7641 1.8340 1.9058 1.9688 2.0211 2.1121 2.1886 2.2476 2.80 1.4182 1.4675 1.5186 1.5755 1.6321 1.6885 1.7426 1.7934 1.8456 1.8958 11.9860 2.0661 2.1344 2.90 1.4113 1.4542 1.4908 1.5257 1.5572 1.5912 1.6271 1.6657 1.7012 1.7333 11.8044 1.8762 1.9349 3.00 1.3759 1.4276 1.4698 1.5087 1.5438 1.5771 1.6086 1.64082 1.6751 1.7083 1.7766 1.8393 1.8873 3.10 1.4103 1.4571 1.4983 1.5396 1.5753 1.6042 1.6288 1.6506 1.6715 1.6970 1.7630 1.8284 1.8832 3.20 1.3920 1.4442 1.4898 1.5359 1.5760 1.6090 1.6378 1.6635 1.6860 1.7079 1.7618 1.8297 11.9223 3.30 1.4213 1.4585 1.4881 1.5268 1.5629 1.5941 1.6243 1.6547 1.6858 1.7160 1.7745 1.8438 11.9203 3.40 1.4957 1.5401 1.5753 1.6201 1.6643 11.7029 1.7391 1.7736 1.8057 1.8348 1.8924 1.9482 2.0090 3.50 1.5312 1.5845 1.6271 1.6710 1.7208 1.7661 1.8085 1.8491 1.8868 11.9215 1.9915 2.0593 2.1207 3.60 1.4783 1.5385 1.5871 1.6361 1.6818 1.7221 1.7602 1.7984 1.8366 1.8733 1.9501 2.0299 2.1065 3.70 1.3408 1.3945 1.4540 1.5129 1.5642 1.6076 1.6468 J1.6824 1.7146 1.7431 1.8027 1.8614 1.9364 3.80 1.2621 1.3119 1.3653 1.4241 1.4756 1.5194 1.5590 1.5951 1.6276 1.6564 1.7086 1.7546 11.7967 3.90 1.2484 1.2760 1.3093 1.3643 1.4171 1.4625 1.5039 1.5418 1.5760 1.6064 1.6633 1.7172 1.7688 4.00 1.2463 1.2744 1.3030 1.3373 1.3677 1.4011 1.4443 1.4847 1.5215 1.5550 1.6218 1.6874 1.7489 4.10 1.2163 1.2441 1.2735 1.3130 1.3491 1.3783 1.4016 1.4278 1.4548 1.4808 1.5453 1.6202 1.6922 4.20 1.1693 1.1786 1.1997 1.2318 1.2699 1.3017 1.3279 1.3490 1.3709 11.4090 1.4852 1.5558 1.6166 4.30 1.2513 1.2665 1.2765 1.2924 1.3095 1.3322 1.3587 1.3842 1.4070 1.4411 1.5127 1.5783 1.6342 4.40 1.2637 1.2744 1.2792 1.2838 1.2996 1.3146 1.3282 1.3491 1.3734 1.4006 1.4718 1.5394 1.5998 4.50 1.2537 1.2655 1.2716 11.2773 1.2836 1.2904 I1.2981 1.3065 1.3147 1.3403 1.3996 11.4622 11.5241

Calc Number: GEO.HB[P.03.02 Rev Number: 0 Sheet Number: I 16,of 349 Date: 08/27/03 4.60 1.2293 1.2456 1.2570 1.2665 1.2751 1.2909 1.3072 1 1.3225 1.3365 1 1.3494 1 1.3734 1 1.4130 1 1.4771 4.70 1.2671 1.2886 1.3041 1.3179 1.3373 1.3577 13773J 1.3960 1.4130 1.4278 1.4529 1.4745 1.5172 4.80 1.2822 1.3113 1.3367 1.3589 1.3769 1.3961 1.4143 1.4319 1.4479 1 1.4603 1.4754 1.5114 1.5650 4.90 1.2691 1.3006 1.3287 1.3546 1.3767 1.3963 1.4151 1.4341 1.4516 1.4654 1.4824 1.4941 1.5498 5.00 1.2507 1.2819 1.3110 1.3393 1.3645 1.3874 1.4094 1.4312 1.4514 1.4676 1.4899 1.5070 1.5402 5.10 1.2583 1.2893 1.3197 1.3497 1.3772 1.4024 1.4271 1.45514 1.4736 1.4918 1.5183 1.5402 1.5639 5.20.

1.2736 1.2950 1.3175 1.3450 1.3731 1.4010 1.4289 1.4561 1.4804 1.5020 1.5401 1.5770 1.6170 5.40 1.3069 1.3221 1.3397 1.3649 1.3948 1.4251 1.45k6'1 1.470 151 3

. -i.'5409 1.589--

1FWT57 1.6836 5.60 1.2160 1.2288 1.2340 1.2342 1.2320 1.2327 1.2353 1.2514 1.2679 1.2836 1.3287 1.3804 1.4331 5.80 1.1640 1.1879 1.2063 1.2206 1.2300 1.2367 1.2425 1.2490 1.2565 1.2643 1.2803 1.2942 1.3050 6.00 1.1300 1.1596 1.1836 1.2048 1.2208 1.2327 1.2426 1.2519 1.2613 1.2707 1.2907 1.3096 1.3267 6.20 1.1310 1.1426 1.1632 1.1838 1.2006 1.2127 1.2206 1.2251 1.2364 1.2473 1.2707 1.2958 1.3222 6.40 1,1560 1.1678 1.1812 1.1994 1.2175 1.2332 1.2455 1.2550 1.2626 1.2688 1.2835 1.2970 1.3092 6.60 1.1274 1.1425 1.1537 1.1647 1.1748 1.1831 1.1894 1.2006 1.2112 1.2207 1.2408 1.2629 1.2873 6.80 1.1162 1.1189 1.1204 1.1278 1.1386 1.1476 1.1549 1.1644 1.1735 1.1808 1.1988 1.2252 1.2528 7.00 1.1205 1.1279 1.1360 1.1449 1.1550 1.1658 1.1777 1.1894 1.2007 1.2111 1.2295 1.2451 1.2593 7.20 1.1289 1.1345 1.1395 1.1533 1.1666 1.1792 1.1915 1.2028 1.2130 1.2220 1.2392 1.2551 1.2696 7.40 1.1283 1.1402 1.1486 1.1552 1.1606 1.1642 1.1662 1.1671 1.1670 1.1723 1.1924 1.2141 1.2345

,.7.60 1.1294 1..1437 --j.1562 1.1659 11729 1.1785 1.1S36 1.167 1.1872 1.I856 1.1819 1.1299 1.2144_

7.80 1.0954 1.1109 1.1266 1.1406 1.1537 1.1642 1.1729 1.1794 1.1833

'i-1847 1.1824- -1j. MY 1.2087 8.00 1.0775 1.0864 1.0944 1.1036 1.1115 1.1185 1.1252 1.1312 1.1364 1.1400 1.1577 1.1762 1.1928 8.50 1.0947 1.0957 1.0965 1.0975 1.0992 1.1010 1.1037 1.1072 1.1114 1.1148 1.1185 1.1181 1.1189 9.00 1.1117 1.1225 1.1320 1.1403 1.1485 1.1558 1.1632 1.1711 1.1789 1.1859 1.1984 1.2094 1.2193 9.50 1.1560 1.1712 1.1836 1.1969 1.2085 1.2189 1.2286 1.2378 1.2455 1.2514 1.2581 1.2632 1.2714 10.00 1.1837 1.1805 1.1858 1.1978 1.2136 1.2311 1.2502 1.2688 1.2850 1.2968 1.3104 1.3193 1.3303

CAi Number: GEOI{BIP.03.02 Rev Number: 0 Sheet Number: 1 17 of -3 49 Table 9-7. Average a pilcation factors for the 10weV r so roile. M-6.0.

Dae-8/70 Per 0.01 1.5335 1.3705 1.2483 1.1519 1.0586 0.9701 0.3888 0.81:51 0.75273 0.7095 0.6298 0.5582 0.5034 0.03 1.7150 1.5112 1.3604 1.2525 1.1497 1(58I0.9643 0.8845 0.8153 0.7687 0.6811 0.6026 0.5430 0.04 1.6084 1.3899 1.2245 1.1223 1.0278 0.9398 0.8598 0.7881 0.7260 J0.6838 0.6054 0.5350 0.4819 0.05 1.5447 1.3123 1.1218 1.0262 0.9401 0.8614 0.7884-0.7232 0.6665 j0.6283 0.5558 0.4901 0.4413

~0 1.5287

.1.25161t.t 1.0385

-0.9284--(0~8494-0.7771 ~-07I 2- -0.6546 0.6048-A 05690 10.4998 0:4197.

0.3952) 0.07 1.4400 1.1753 10.98107 0.861 8 0.7795 0.7191 0.6636 0.6134 0.5705 O.-5354 0.4689 0.4096 0.3671 0.08 1.6694 1.3176 11.0869 0.9425 0.8345 0.7464 0.6767 0.615'2 0.5630 0.5215 0.4543 0.3939 0.3510 0.09 1.6544 1.3522 11.1041 0.9478 0.833-2 0.74-28 0.6692 0.6051 0.5512 j0.5021 0.4288i 0.3689 0.3246 0.10 1.7507 1.3860 1.0869 0.936 0.7902 0.7104 0.6433 0.5857 0.5341 I0.4883 0.4119 0.3549 0.3110 0.11 1.7273 1.3744 1.0832 0.8778 0.7652 0.6921 0.6345 0.5857 0.5403 0.4991 0.4209 0.3493 0.3022 0.12 1.7860 1.4506 1.1431 0.9197 0.8022 0.7212 0.6569 0.6030 0.5554 0.5115 0.4301 0.3553 0.29,84 0.13 1.7852 1.4467 1.1799 1.0191 0.8956 0.7940 0.7112 0.6480 0.5919 0.5433 10.4528 0.3718 0.3107 0.14 1.9304 1.5731 1.2902 1.1248 1.0034 0.9066 0.8121 0.7212 0.6356 0.5661 0.4734 0.3863 0.3 226 0.15 2.t3303 1.6496 1.3415 1.1132 0.980 0.8985 0.8209 0.7409 0.6636 0.5945 0.4743 0.3878 0.3212 0.16 2.2017 1.7823 1.4937 1.2781 1.0847 10.9273 0.8102 0.7178 0.6468 0.5850 0.4826 0.4026 0.3378 0.17 2.3793 1.9440 1.5981 1.3498 1.1744 1.0313 0.9129 0.8201 0.7390 0.6715 0.5612

.0.4694 0.3930

-0.18--

2.2964

--199t 1.6869 1.4375

-1:2292Z 1.0669 O.N 5:B.8498.

0.7632' 0.6889 0.5703-

-0.4741 0.4024 0.19 2.4085 1.9627 1.6989 1.5311 1.3723

-1.2136 1.0695 0.9419 0.8344 0.7578 0.6333 0.5322 0.4552 0.20 2.4923 2.0136 1.6916 1.4862 1.3404 1.1987 LO070 0.9724 0.8906 0.8190 0.694J 0.5872 0.5000 0.21 2.4078 2.0312 1.7825 1.5582 1.3735 1.2231 1.0991 0.9955 0.9103 0.8411 0.7174 0.6078 10.5227 0.22 2.3862 2.0559 1.8264 1.6094 1.4148 1.2548 1.1258 1.0219 0.9372 0.8642 0.7353 0.6'213 0.5380 0.23 2.5128 2.1306 I1.8479 1.6364 1.4600 11.3046 1.1717 1.0612 0.91718 0.8980 0.7757 10.6675 0.825 0.24 2.5291 2.1679 11.8895 1.6746 1.489-7 11.3262 1.1946 1.0843 0.9971 0.922-2 0.7970 0.6867 0.6008 0.25 2.5782 2.1830 1.9234 1.7095 1.5213 1.3577 1.2245 11.1145 1.0270 0.9540 0.8252 0.7062 0.6201 0.26 2.8361 2.3594 2.0101 1.7765 1.5864 1.4254 1.2915 1.1874 1.1022 1.0257 10.8975 0.7681 0.6662 0.27 2.9639 2.5725 2.1641 1.8696 1.6420 1.4554 1.3136 1.2023 1.1103 1.0338 0.9187 0.7992 0.7013 0.28 2.8847 2.5537 2.1841 1.9066 1.6776 1.4839 1.3303 1.2147 1.1245 1.0470 0.9219 0.8073 10.7092 0.29 2.8075 2.5656 2.3760 2.0991 1.8064 1.5723 1.4033 1.2909 1.2064 1.1284 0.9811 0.8437 0.7381 0.30 2.7213 2.6243 2.4646 2.1882 1.8944 1.6609 1.4871 1.3536 1.2465 1.1537 1.0063 0.8642 0.7540 0.31 2.7179 2.6309 2.4131 2.1667 1.9312 1.7191 1.5415 1.3939 1.2691 1.1593 0.9983 0.8522 0.7421 0.32 2.7448 2.6562 2.4553 2.2260 2.0064 1.8302 1.6603 1.5062 1.M372 1.2511 1.0476 0.8893 0.7742 0.33 2.7804 2.7064 2.5204 2.3360 2.1705 1.9902 1.8122 1.6457 1.515 1.3726 1.1511 0.9796 0.8548 0.34 2.5747 2.5482 2.4764 2.3665 2.2071 2.0292 1.8535 1.6900 1.5475 1.4185 1.1906 1.0157 0.8858 0.35 2.4637 2.5343 2.5073 2.4080 2.2519 2.0756 1.9009 1.7414 1.6006 1.4761 1.2698

-1.0829 0.9426 0.36 2.4975 2.5839 2.5731 2.4760 2.3187 2.1855 2.0412 1.8961 1.7652 1.6400 1.4072 1.2102 11.0532 0.37 2.2942 2.3844 2.4665 2.4588 2.3709 2.2448 2.1060 1.9647 1.8325 1.7042 1.4844 1.2702 11.1011 0.38 2.1937 2.2572 2.3488 2.3615 2.3203 2.2276 2.1143 1.9942 1.8997 1.7983 11.5791 1.3569 1.1664 0.39 2.0959 2.1169 2.1735 2.2262 2.2032 2.1312 2.0487 1.9790 1.9029 1.8124 11.5982 1.3791 1.1926 0.40 2.0119 2.0243 2.0793 2.13 1 2.1218 2.0813 2.0301 1.9764 1.9150 1.8358 1.6369 1.4148 1.2296 0.41 1.9780 1.9970 2.0395 2.0868 2.0905 2.0720 2.0370 1.9891 1.9305 1.8593 1.6769 1.4610 1.2719 0.42 1.9612 1.9691 2.0016 2.0393 2.0512 2.0372 2.0190 1.9909 1.9423 1.8747 1.7097 1.5086 1.3262 0.43 1.9381 1.9109 1.9243 1.9334 1.9476 1.9773 1.9890 1.9852 1.9654 1.9183 1.7624 1.5602 1.3779 0.44 1.9725 1.9293 1.8969 1.9143 1.9156 1.9449 1.9755 1.9806 1.9740 1.9479 1.8061 -1.5963 1.4197 0.45 1.9984 1.9146 1.8401 1.8264 1.8114 1.8179 1.8362 1.8593 1.8654 1.8427 1.7274 1.5654 1.4258 0.46 2.0198 1.9429 1.8659 1.7981 1.7444 1.7360 1.7457 1.7507 1.7518 1.7367 1.6583 1.5379 1.4192 0.47 2.0302 1.9579 1.8843 1.8139 1.7569 1.7089 1.7078 11.7159 1.7203 1.7080 1.6338 1.5210 1.4218 0.48 2.0437 1.9729 1.8999 1.8293 1.7624 1.7159 1.6789 1.6797 1.6811 1.6700 1.6070 1.5094 1.4163 0.49 2.0547 1.9816 1.9083 1.8380 1.7661 1.7121 1.6766 1.6489 1.6455 1.6382 1.5824 1.4922 1.4073 0.50 2.0735 1.9910 1.9191 1.8493 1.7792 1.7176 1.6729 1.6477 1.62-99 1.60-75 1.5602 1.4794 1.4033 0.51 2.1478 2.0501 1.9644 1.8888 1.8159 1.7486 1.6923 1.6455 1.6195 1.5989 1.52~99 1.4547 11.3880 0.52 2.1748 2.0448 1.9618 1.8896 1.8193.1.7538 1.6985 1.6525 1.6167 1.5776 11.4859 1.3934 11.3329 0.53 2.2276 2.0512 1.9633 1.8919 1.8244 1.7602 1.7067 1.6614 1.6264 1.5883 1.4946 1.3984 1.3319 0.54 2.2754 2.1057 1.9733 1.8972 1.8316 1.7687 1.7145 1.6693 1.6339 1.5965 1.5035 1.4043 1.3403 0.55 2.2652 2.1067 2.0095 1.9140 1.8270 1.7638 1.7099 1.6641 1.6283 1.5904 1.4985 1.4012 1.3363 0.56 2.2183 2.1061 12.0186 1.9283 1.8426 1.7555 1.7013 1.6546 1.6185 1.5804 1.4898 1.3948 1.3291 0.57 2.1709 2.1116 2.0292 1.9447 1.8582 1.7696 1.6958 1.6489 1.6124 1.5749 1.4852 1.3923 1.3292 0.58 2.1669 2.1140 2.0354 1.9549 1.8676 1.7779 1.6963 1.6318 1.5960 1.5588 1.4714 11.3820 1.3223 0.60 2.1605 2.1176 2.0547 1.9702 1.8901 1.8107 1.78 1.6517 1.5879 1.5308 1.4339 1.3508 1.2979 0.62 2.1226 2.1604 2.1210 2.0449 1.9482 1.8542 1.773 1.6882 1.6130 1,5529 1.4295 1.3316 1.2798 0.64 2.0678 2.1044 2.1155 2.0764 2.0030 1.9052 1.8085 1.7106 1.6295 1.5547 1.4212 1.3203 1.2709 0.66 2.0623 2.0765 2.1130 2.1-221 12.0936 2.0-258 1.9274 1.8129 1.6992 1.6062 1.4366 1.3239 1.2643 0.68 2.0109 2.0561 2.0994 2.1313 I2.1181 2.0570 1.9664 11.8783 1_1.7844 1.6794 1.4897 f1.3540 -1.2725

,i Calc Number: GEO. HB [P.03.02 Rev Number: 0 Sheet Number: I IS8 of 349

~~~~~~~~~~~Date:

08/27/03 0.70 1.9545 2.0121 2.0703 2.09819 2.11411 2.08157 2.0202 t.9398 1E.

741

.60

.315 125 0.72 1.8703 1.9325 2.0011 2.05081 2.0786 2.0623 2.0125 1.95815 1.9091 J 1.11394 1.6523 1.4629 11.3515 0.74 1.6931 1.7512 1.8016 1.8640 1.91111 1.9558 1.9713 1.9562 1.918J1.56 1.61100 1.4879 130 0.76 1.6843 1.7227 1.7819-I.R617 1.9237 1.9652 1.9714 1.9454 1.9086 -

1.11764 1.76111 1.6202 11.5065 0.78 1.7250 1.7424 1.7815

1. 8215 1.11759 1.9122 1.9293 1.9296 1.9159 1.8834 1.7633 1.6276 11.5378 0.80 1.7403 1.7602 1.7939 1.8307 1.8494 1.8554 1.8609 1.11631 1.8518 1.81222 1.7420 1.6422 11.55119 0.84 1.7548 1.7679 1.79381 1.8254 1.11423 1.8478 1.8482
1. E447 1.11374 1.8197' 1.7664 1L.6O10

-1.0092 0.86 1.7464 1.7472 1.7704 1.8000 1.81167 1.8227 1.8240 1.81223 1.81166 1.8056 11.7687 1.6934 1.6252 0.88 1.749 1.7408 1.7445 1.7724 1.78193 1.7961 1.7990 1.79981 1.81045 1.8032 1.7721 1.7050 1.6415 0.90 1.8606 1.8049 1.7735 1.7616 1.7708 1.7776 1.7846 1.7911 1.7957 1.7952 1.76819 1.7079 1.6484 0.92 1.9025 1.8568 1.8069 1.7889 1.7717 1.7537 1.7480 1.7530 1.7565 1.7556 1.7313 1.6807 1.6381 0.94 1.9130 1.8737 1I.S822 1.7958 1.7684 1.7487 1.7349 1.7276 1.7248 1.7231 1.7066 1.6609 11.6200 0.96 1.9337 1.8950 1.S517 1.8194 1.7802 11.7505 1.7341 1.72311 1.7180 1.7137 1.6946 1.6513 11.61511 0.98 1.9558 1.9168 1.8756 1.8443 1.8042 1.7667 1.7405 1.7275 1.71119 1.7123 1.6907 1.6531 11.6176 1.00 1.9772 1.9386 1.8994 1.8694 1.8292 1.7902 1.7600 1.7385 1.7263 1.7175 1.6976 1.6595 11.6242 1.05 2.0319 1.9926 1.95781 1.9324 1.8931 1.8525 1.8185 1.7921 1.7730 1.75113 1.7299 1.6881 11.6523 1.10 2.0838 2.0427 2.0101 1.9883 1.9508 1.9104 1.8751 1.8466 1.8246 1.8061 1.7693 1.7229 1.61166 1.15...2.1122 2.0699

-2O41.-.2.0025 1.9687

.1.9306 1.8964 1.8738 1.8553 1.8372 1.7980 1.7506.1.

1.7131 1.20 2.2407 2.1709 2.1206 2.0896 2.04211' 2.0016 1.9682 1.9384 1.9129 1.8882 1.8329 1.7856 11.7491 1.25 2.3712 2.2955 2.2301 2.1909 2.14081 2.0982 2.0657 2.0355 2.0088 1.91130 1.9254 11.85381 1.7916 1.30 2.4065 2.3345 2.2567 2.2165 2.1741 2.1271 2.0862 2.0607 2.0383 2.0160 1.9651 1.9003 11.8421 1.35 2.4457 2.4037 2.3482 2.2983 2.2362 2.1801 2.1393 2.09115 2.0592 12.0236 11.9812 1.9253 11.11716 1.40 2.5543 2.5200 2.4753 2.4321 2.3680 2.2892 2.2096 2.1565 2.1215 2.0862 12.0111 1.9607 11.9093 1.45 2.6653 2.6375 2.5971 2.5569 2.49481 2.4176 2.3400 2.2638 2.1900 2.1-l3 30 2.0279 1.9594 11.9101 1.50 2.7638 2.7373 2.6935 2.6521 2.5878 2.5086 2.4298 2.3520 2.2759 2.1999 2.0808 1.9734 11.9242 1.55 2.7801 2.7643 2.7267 2.6905 2.6333 12.5645 2.4927 2.4200 2.3479 2.2743 2.1373 2.0184 1.9452 1.60 2.7249 2.7215 2.6981 2.6820 2.6427 2.5858 2.5233 2.4585 2.3933 2.3252 2.1775 2.0625 1.9856 1.65 2.7074 2.7217 2.7084 2.6955 2.6627

'2.6144 2.5592 2.5004 2.4402 2.3762 2.2334 12.1067 2.0280 1.70 2.7057 2.7314 2.7264 2.7171 2.6894 2.6473 2.5974 2.5423 2.4849 2.4229 12.2828 12.1717 2.01155 1.75 2.6633 2.7052 2.7145 2.7129 2.6900 2.6520 2.6056 2.5530 2.4969 2.4505 2.3589 12.26 17 2.1825 1.80 2.5377 2.5905 12.6122 2.6493 2.6783 2.7026 2.7224 12.7211 2.7033 2.6764 2.5893 12.4565 2.3212 1.85 2.4677 2.5453 2.6303 2.7207 2.7936 2.8368 2.8527 !2.8554 2.8510 2.8337 2.7518 2.6176 12.4782 1.90 2.4186 2.5300 2.6469 2.7470 2.8306 2.8869 2.9153 2.9203 2.9075 2.81903 2.8203 2.6965 2.5663 1.95 2.4085 2.4874 2.5723 2.6436 2.7101 2.7728 2.8202 2.8498 2.8654 2.8675 2.8265 2.7255 2.6052 2.00 2.3827 2.4646 2.5479 2.6206 2.6863 2.7508 2.8028 2.8386 2.8610 12.8701 2.8457

'2.7616 2.6509 2.05 2.3083 2.3833 2.4719 2.5447 2.6123 2.6683 2.7211 2.7628 2.7914 12.8080 2.8016 2.7357 2.6361 2.10 2.2395 2.2929 2.3769 2.4522 2.5227 2.5838 12.6368 2.6805 2.7117 12.7315 2.7350 2.7204 2.6678 2.15 2.2033 2.2422 2.2733 2.3437 2.4269 2.5022 2.5702 2.6273 2.6726 12.7068 2.7432 2.7464 2.7055 2.20 2.1726 2.2173 2.2705 2.3291 2.4168 12.5002 2.5685 2.6235 2.6673 12.7009 2.7425 2.7512 2.7098 2.25 2.1255 2.1941 2.2607 2.3224 2.4020 2.4754 2.5363 2.5856 2.6268 12.65114 2.7301 2.7691 2.7628 2.30 2.1072 2.1769 2.2381 2.2892 2.3561 2.4347 2.5076 2.573 1 2.6310 12.68111 2.7643 2.8255 2.8569 2.35 2.1077 2.1685 2.2357 2.2932 2.3458 2.4242 2.5004 2.5696 12.6314 12.6994 12.8319 2.9280 2.9682 2.40 2.1006 2.1697 2.2376 2.3004 2.3604 2.4444 12.5335 2.6149 12.6885 12.7552 12.8773 2.9799 3.0235 2.50

-2.0405 2.1093 2.1742 2.2315 2.2980 2.3889 2.4748 2.5528 2.6231 12.6887 12.8085 2.9032 2.9470 2.60 1.9359 1.9868 2.0294 2.0757 2.1359 2.1921 2.2433 2.3051 2.3629 12.4174 12.5179 2.6122 2.6842 2.70 1.9314 1.9904 2.0384 2.0821 2.1295 2.1899 2.2495 2.3040 2.3552 2.4043 12.5001 2.6051 2.6853 2.80 1.9044 1.9642 2.0124 2.0542 2.0970 2.1445 2.1891 2.2349 2.2785 12.3241 12.4129 12.4961 2.5692 2.90 1.7929 1.8505 1.9032 1.9467 1.9886 2.0287 2.0655 2.0991 2.1340 12.1719 12.2472 12.3189 12.3734 3.00 1.7262 1.7715 1.8176 1.8586 1.8978 1.9322 1.9621 1.9896 2.0161 12.0419 12.0909 12.1502 12.2062 3.10 1.6946 1.7291 1.7612) 1.7984 1.8392 1.8758 1.9073 1.9354 1.9618 11.9871 12.0349 12.0764 2.1039 3.20 1.6876

'1.7250 1.7629 1.7989 1.8309 1.8600 1.8924 1.9224 1.9493 11.9740 12.0179 12.0557 12.0823 3.30 1.7039 1.7373 1.7753 1.8132 1.8487 1.8810 1.9086 1.9328 1.9552 11.9765 12.0169 12.0585 12.1118 3.40 1.7164 1.7456 1.7763 1.8070 1.8344 1.8597 1.8877 1.9132 1.9363 11.9581 11.9989 12.0347 12.0868 3.50 1.6972 1.7272 1.7584 11.7913 1.8229 1.8521 1.8785 1.9025 1.9251 11.9468 11.9881 2.0238 2.0640 3.60 1.6737 1.6936 1.7236 1.7565 1.7916 1.8253 11.8550 1.8812 1.9047 11.9262 11.9635 2.002 1 2.0364 3.70 1.6624 1.6819 1.7055 1.7426 1.7804 1.8175 1.8508 1.8802 1.9063 11.9304 11.9727 2.0049 2.0219 3.80 1.6576 1.6757 1-6934 1.7190 1.7585 1.7986 1.8350 1.8673 1.8962 1.9226 11.9693 2.0056 2.0261 3.90 1.6701 1.6919 1.7086 1.7286 1.7592 1.7997 1.8385 1.8734 1.9048 1.9334 11.9842 2.0245 2.0481 4.00 1.6925 1.7181 1.7378 1.7585 1.7861 1.8200 1.8582 1.8951 1.9287 1.9597 2.0148 12.05119 2.01157 4.10 1.6689 1.6984 1.7207 1.7420 1.7690 1.8006 1.8348 1.8700 1.9040 1.9358 1.9931 2.0396 2.0685 4.20 1.6345 1.6685 11.6968 1.7247 1.7558 1.7863 1.8134 11.8367 1.8562 1.8756 1.9323 1.9789 2.0088

.4.30 1.6135 I1.6513 11.6818 1.7108 1.7427 1.7737 1.8011 1.8251 1.8454 1.8628 1.8905 1.9144 1.9450 4.40 1.6039 I1.6369 1.6659 1.6945 1.7266 1.7580 1.7860 1.8106 1.8317 1.11498 1.8787 1.8986 1.9096I 4.50 1.6097 1.6452 11.6766 1.7025 1.7259 I1.7469 I1.7718 1.7971 1.8191 1.8381 1 1.8684 1.8898 1.9041j

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 119 of 349 Date: 08/27/03 4.60 1.6157 1.6532 1.6867 1.7144 1.7395 1.7618 1.7811 1.79S3 1.8138 1 223 1.8605 I.X839 1.9026 4.70 1.6202 1.6603 1.6965 1.7263 1.7527 1.7765 1.7974 1.8162 1.8329 1.8476 1.8723 1.8913 1.9050 4.80 1.5952 1.6361 1.6737 1.7048 1.7319 1.7570 1.7792 1.7987 1.8166 1.8325 1.8600 1.8X21 1.8943 4.90 1.6031 1.6242 1.6472 1.6710 1.6990 1.7249 1.7477 1.7686 1.7874 1.8046 1.S350 1.8605 1.8749 5.00 1.6051 1.6272 1.6504 1.6722 1.6909 1.7065 1.7202 1.7331 1.7454 1.7634 1.7966 1.825.1 1.8415 5.10 1.6171 1.6422 1.6630 1.6785 1.6959 1.7117 1.7247 1.7374 1.7496 1.7618 1.7870 1.8141 1.8354 5.20 1.636-. _.L6615 1.6832 L699...1.71.10 1.7202..7335 1.7461

. 1,7584 1.7706 1.7971 1.X259 1.8483 5.40 1.6472 1.6727 1.6947 1.7121 1.7249 1.7339 1.7408 1.7465 1.7592 1.772 I 1.8006 1.8326 1.8571 5.60 1.6078 1.6300 1.6516 1.6699 1.6839 1.6950 1.7036 1.7111 1.7182 1.7305 1.7606 1.7947 18208 5.80 1.5497 1.5682 1.5907 1.6102 1.6254 1.6383 1.6488 1.6580 1.66S9 1.6822 1.7132 1.7491 1.7766 6.00 1.5237 1.5406 1.5621 1.5S17 1.5993 1.6166 1.6328 1 6476 1.6622 1.6758 1.7050 1.7416 1.7708 6.20 1.4702 1.4845 1.5029 1.5234 1.5424 1.5616 1.5789 1.5954 1.6103 1.6249 1.6557 1.6940 1.7238 6.40 1.4684 1.4616 1.4579 1.4736 1.4948 1.5146 1.5328 1.5480 1.5622 1.5765 1.6107 1.6502 1.6799 6.60 1.4597 1.4536 1.4491 1.4483 1.4435 1.4512 T 1.4660 1.4785 1.4921 1.5062 1.5397 1.5780 1.6065 6.80 1.4557 1.4502 1.4470 1.4458 1.4428 1.4375 1.4353 1.4397 1.4539 1.4682 1.5016 1.5391 1.5669 7.00 1.4460 1.4483 1.4505 1.4522 1.4529 1.4509 1.4503 1.4522 1.4563 1.4637 1.4902 1.5275 1.5562 7.20 1.4670 1.4699 1.4733 1.4747 1.4766 1.4762 [ 1.4769 1.4798 1.4846 1.4923 1.5198 1.5575 1.5864 7.40 1.5123 1.5124 1.5177 1.5207 1.5236 1.5250 1.5269 1.5315 1.5371 1.5453 1.5738 1.6126 1.6417

'.J 7.60 1 1.5241 1. 1.5M92 I 1.5328 1.-1 5375J. 1.5416 I 1.5439A...1.5469 1 1.551S,.,

.1.55S81A.--1.5669 I 1.5948 I.1.6331 1 1.6617 7.80 1.5048 1.5087 1.5161 1.5212 1.5257 1L5296 1.5328 1.5377 1.5436 1.5516 1.5779 1.6143 1.6421 8.00 1.4916 1.4973

-1.5047 1.5110 1.5176 1.5209 1.5245 1.5298-1.5350 1.5430 1.567S 1.6024 1.6292 8.50 1.5025 1.5091 1.5189 1.5278 1.5378 1.5424 1.5471 1.5523 1.5576 1.5648 1.5871 1.6176 1.6420 9.00 1.5069 1.5163 1.5305 1.5423 1.5532 1.5585 1.5628 1.5682 1.5739 1.5803 1.5986 1.6244 1.6463 9.50 1.5096 1.5126 1.5280 1.5419 1.5544 1.5596 1.5636 1.5674 1.5730 1.5786 1.5932 1.6144 1.6340 10.00 1.5256 1.5205 1.5362 1.5523 1.5625 1.5672 1.5700 1.5728 1.5768 1.5825 1.5935 1.6107 1.6280 ]

L Calc Number: GEO.HBIP.0' ).02 Rev Number: 0 Sheet Number: 120 of' )49 Date: 08/27/03 Table 9-8. Average axnvilfication factors for the low r soil profile. M-7.0.

Per-0.1st 0.2iz 9

0.51Z 0.6 0.7 O.sg 0.9g (see)

UP 0.4

_R I g

Loe 1.2z 1-4c 1.6e.

0.01 1.5524 1.4049 1.2415 1.1406 1.0728 1.0003 0.9232 0.8447 10.7773 0.7276 10.6454 10.51t I 8 0.5237 0.03 1.5964 1.4461 1.2741 1.1663 1.0961 1.0214 0.9420 O8615 10.79-22 0.7406 0.6557 0.5909 0.5318 0.04 1.4417 1.2894 1.1311 1.0311 0.9685 0.9019 0.8312 0,7597 10.6992 0.6520 0.5764 0.3192 0.4672 0-05 1.3640 1.1.846-...1.0324

.0.9433

. 0.8849 0.8236 0.7582 0.6920 0.6356 Q.5933 6.5238 0.471 'it 0.4247

'6.06 1.3415 1.1211 0.951ti 0.8 5 8 6 0.801,9 0.7468 0.6872 0,6273 0.5756

--rO. 310

-0.4734 0.4261 0.3835 0.07 1.2242 1.0658 0.9099 0.8063 0.7496 0.6944 0.6379 0.5808 0.5323 0.4953 0.4357 0.3922 0.3530 0.09 1.2582 L0441 0.8,177 0.7645 0.7073 0.6529 0.5975 0.5424 0.4963 0.4615 0.4045 10.3639 0.3274 0.09 1.2938 1.0030 0.9574 0.7701 0.7025-0.6408 0.5813 0.5237 0.4757 0.4387 0.3826 0.3442 0,3106 0.10 1.3233 1.0026 0.8165 0.7344 0.6790 0.6230 0.5661 10.5110 0.4639 0.4275 0.3690 0.3306 10.2954 0.11 1.4736 1.1159 0.8923 0.7443 0.6398 0.5872 0.5347 10.4836 0,4399 0.4055

0. 496 0.3120 0.2791 0.12 1.5171 1.1164 0.9112 0.7566 0.6651 0.6032 0.5436 0.4970 0.4396 0.4036 0.3437 0.3061 0.2724 0.13 1.5005 1.0574 0.9909 0.7605 0.6903 0.6232 0.5593 0.4996 0.4494 0.4108 0.3496 0.3065 01717 0.14 1.6756 1.1397 0.8947 0.7680 0.6715 0.5993 0.5405 0.4946 0.4378 0.4001 0.3408 0.2973 0.2635 0.15 1.7719 1.2000 0.9%85 0.8226 0.7069 0.6252 0.5516 0.4810 0.4252 0.3898 0.3343 0.2920 0.2591 0.16 1.8192 1.3250 1.1120 0.9014 0.7377 0.6227 0.5487 0.4826 0.4243 0.3821 0.3287 0.2885 10.2568 e.0.17 1.8435 1.4092 1.1931 0.9787

-038?4-0.6519 0.5432

-.0.4805 0.4268 0.3849 0.3315 0.2930

..0.2635 0.18 1.8343 1.5552 1.2732 1.0462 0.8591 0.7130 0.5909 0.3061 0.4484 0.3999 0.3358 0.2937 10.2593 0.19 1.7685 1.4569 1.2772 1.0572 0.9973 0.7723 0.6587 0.5775

-0.5121 0.4538 0.3637 0.3151 10.2764 0.20 1.9216 1.4479 1.3053 1.1222 0.9490 0.8052 0.6849 0.6004 0.5338 0.4738 0.3768 0.3245 10.2815 0.21 1.9690 1.5959 1.3428 1.1609 0.9964 0.8291 0.7236 0.6411 0.5702 0.5070 0.4129 0.3502 03024 0.22 1.9026 1.5909 1.3589 1.1609 1.0004 0.8659 0.7524 0.6637 0.5932 0.5284 0.4301 0.3612 0.3106 0.23 2.0139 1.6842 1.4665 1.2833 1.0762 0.9182 0.7997 0.7100 0.6365 0.5800 0.4800 0.4001 0.3386 0.24 2.0619 1.6161 1.4244 1.2871 1.1135 0.9530 0.8321 0,7431 0.6614 0.5856 0.4699 0.3916 0.3316 0.25 2.2286 1.7065 1.429-2 1.2712 1.1342 1.0033 0.8677 0.7548 0.6724 0.5956 0.4775 0.3989 0,3399 0.26

-2.4279 1.9048 1.5095 1.2563

1. 1472 1.0315 0.9019 0.7847 0.6915 0.6078 0.4810 0.4031 0.3513 0.27 2.4720 2.0367 1.6360 1.3386 1.1447 0.9787 0.8339 0.7439 0.6652 0.5962 0.4843 0.410-7 10.3592 0.28 2.4958 2.1343 1.7268 1.4209 1.2204 1.0560 0.9267

-0.9232 O.-7317 0.6577 0.5410 0.4587 o,3984 0.29 2.5041 2.1208 1.7323 1.4614 1.2647 1.1020 10.9693 I0.8640 0.7696 0.6975 0.5696 0.4804 0.4114 0.30 2.3626 2.0255 1.6983 1.4760 1.2885 1.1282 0.9977 0.8906 0.7989 0.7141 0.5963 0.5063 14350 0.31 2.4246 2.0632 1.8071 1.5781 1,3600 1.1773 1.0211 0.9041 0.7976 0.7062 0.5920 0.5055 0.4356 0.32 2.5860 2.1612 1.9223 1.6868 1.462.8 1.2354 1.0563 0.9257 0.8112 0,7138 0.5868 0.5053 0.4430 0.33 2.7163 2.3748 2.1668 1.9184 1.6509 1.4014 1.1759 1.0277 0.9035 0.7901 0.6365 0.5423 0.4720 0.34 2.4672 2.3201 2.1467 1.9373 1.6939 1.4463 1.2229 1.0672 0.9421 0.9265 0.6676 0.5685 fOA930 0.35 2.3034 2.2749 2.1130 1.9177 1.6959 1.4724 1.2563 1.1167 0.9977 0.8790 0.7197 0.6123 0.5310 0.36 2.2370 2.2252 2.0695 1.8632 1.6922 1.5116 1.3583 1.2076 1.0640 0.9422 0.7732 0.6579 0.570-7 0.37 2.1024 2.1128 2.0123 1.8295 1.6710 1,5521 1.4066 1.2554 1.1248 1.0077 0.8309 0.7076 0.6150 0.38 1.9961

1.0614 1.9561 1.9208 1.6729 1,5504 1.4144 1.2777 1.1521 11.0362 10.8585 0.7339 0.6388 0.39 1.8934 1.9742 1.9294 1.8596 1.7626 1.6463 1.5039 L3532 1.2091 1.0807 0.8932 0.7637 O6666 0.40 1.9034 1.9136 1.9012 1.8729 1.7928 1.6843 1.5494 1.4023 1.2587 1.1293 0.9309 10.7922 10.6934 0.41 1.8785 1.8411 1.8114 1.8236 1.8105 1.7044 1.5675 11.4323 1.2916 1.1630 0.9638 0.8252 0.7221 0.42 1.8351 1.8026 1.7434 1.8006 1.8151 1.7326 1.5934 11.4536 1.3155 1.1876 0.9922 0.9586 0.7531 0.43 1.7876 1.7-729 1.7036 1.7385 1.7765 1.7260 1.6013 1.4797 1.3454 1.2153 1.0280 0.9907 0.7925 0.44 1.7379 1.7144 1.6599 1.6273 1.6589 11.6462-1.5659 1.4562 1.3323 1.2181 1.0381 0.9002 0.7924 0.45 1.7406 1.6767 1.6343 1.6056 1.6025 1.5912 1.5443 1.4777 1.3786 1.2624 1.0647 0.9215 0.8126 0.46 1.7096 1.6439 1.5993 1.5769 1.5704 1.5585 1.5325 1.4695 1.3738 1.2613 1.0731 10.9398 10.8296 0.47 1.7163 1.6498 1.6093 1.5841 1.5700 1.5319 1.4765 1.4141 1.3379 1.2569 1.0986 10.9613 0.8483 0.48 1.7273 1.6497 1.6129 1.5855 1.5691 1.5290 1.4662 1.4191 1,3616 1.2888 1.1309 0.9932 0.8791 0.49 1.7251 1,6579 I1.6158 1,5770 1.5571 1.5166 1.4533 11.4091 1.3575 1.2893 1.1378 1.0033 0.8912 0.50 1.6909 1.6467 1.6092 1.5732 11.5512 1.5101 1.4490 1.3938 1.3459 1.2820 1.1369 i.oO64 0:9003 0.51 1.6850 1.6433 1.6013 1.5671 1.5441 1.5036 1.4453 1.3837 1.3330 1.2710 1.1288 1.0038 0.8993 0.52 1.6851 1.6406 1.5977 1.5630 1.5390 1.4990 1.4428 1.3844 1.3254 1.2567 1.1172 0.9947 0.8905 0.53 1.6858 1.6392 1.5960 1.5599 1,5352 1.4955 1.4412 1.3849 1 1.3-279 1.2606 1.1228 1.0014 0.8966 0.54 1.7618 1.6486 1.5964 1.5591 1.5330 1.4930 1.4401 1.3858 13304 1.2644 1.1282 1.0079 0.9041 0.55 1.8111 1.6940 1.5989 1.5597 1.5318 1.4909 1 1.4390 1.3864 1.3324 1.2677 1.1337 1.0148 0.9122 0.56 1.8657 11.7595 1.6079 1.5607 1.5307 1.4890 1.4380 1.3869 1 1.3346-1 1.2716 11.1398 1.0226 0.9273 0.57 1.9363 1.8262 1.6637 1.5616 1.5295 1.4873 1.4371 1.3876 1.3373 1.2762 1.1470 1.0316 0.9359 0.58 1.9989 1.9762 1.7112 1.6011 1.5279 1.4855 1.4362 1.3891 1.3409 1.2816 1.1552 1.0416 0.9424 0.60 2.0634 1.9563 1.7671 1.6356 1.5917 1.5170 1.4417 1.3726 1.3292 1.2747 1.1559 1.0466 0.9590 0.62 2.0487 1.9688 1.8179 1.7097 1.6423 1.5831 1.5159 1.4516 1.3879 1.3162 1.1722 1.0554 0.9717 0.64 1.9586 1.9594 1.9387 1.7196 1.6287 1.5765 1.5175 4614 1.4035 1.3346 1.1927 1.0754 0.9890 0.66 1.9114 8295 1.7092 1.6262 1.5769 1.5250 1.4758 1.4230 1.3573 1.2171 1.0992 1.0104 0.68 1 1.8089 12 1.6997 1 1.6453 1.5861 1.5405 1.4970 1.3853 1.2450 1.1254 1.0334

Caic Number: GEO.HBIP.03.02 Rev Number: 0 Sheet. Number: 121 of '349

____Date: 08/27/03 0.70 1.7307 1.7769 1.7626 31.7122 1.6682 1.6086 1.5615 1.5219 31.4763 1.4141 i1.2715 1.1489 i.053.

0.72 1.7188 1.7578 1.7673 j1.7254 1.6815 1.6285 1.5828 1.5457 1.5020 1.4403 1.2948 1.1693 1.0718 0.74 1.7117 1.7285 1.7359 1.7109 1.6894 1.6408 1.6023 1.5678 1.5266 1.4654 1.3176 1.1895 1.0901 0.76 1.7070 1.7137 1.7109 1.7093 1.7087 1.6798 1.6260 1.5921 1.5539 1.4934 1.3430 1.2121 1.1110 0.78 1.6870 1.7000 1.7337 1.7560 1.7578 1.7282 1.6721 1.6144 1.5685 1.5098 1.3583 1.2325 1.1298 0.80 1.6436 1.6608 1.6736 1.7014 1.7061 1.6785 1.6266 1.5926 1.5600 1.5097 1.3750 1.2479 1.1437 0.82 1.6457 1.6414' 11.6322 1.6391 1.6451 1.6412 1.6210 1.6021 1.5826 1.5527 1.4484 1.3228 1.2064

  • 0.84 "r:27 1.6131-1:6o94-

-1.6329 r.6~6' T6~1 V46

.3 1.6188 1:5904 14829 1.3533-D1246 0.86 1.6233 1.6189 1.6162 1.6138 1.6484 1.6663 1.6580 1.6414 1.623%

1.5972 1.4894 L.3678 1.2564 0.88 1.6926 1.6432 1.6155 1.6139 1.6362 1.6372 1.6227 1.6107 1.5970 1.5727 1.4848 1.4074 1.3223 0.90 1.6772 1.6346 1.6139 1.6169 1.6111 1.5926 1.5688 1.5526 1.5421 1.5292 1.4696 1.3911 138 0.92 1.6702 1.6286 1.6242 1.6310 1.6292 1.6131 1.5894 1.5717 1.5591 1.5444 1.4832 1.3893 136 0.94 1.6960 1.6476 1.6330 1.6416 1.6432 1.6300 1.6079 11.5906 1.5772 1.5617 1.4996 1.4070 1.3120 0.96 1.7236 1.6676 1.6500 1.6524 1.6559 1.6452 1.6250 1.6087 1.5953 1.5793 11.5 177 1.4270 1.3245 0.98 1.7458 1.6842 1.6680 1.6627 1.6665 1.6575 1.6391 1.6241 1.6108 1.5952 11.5349 1.4472 1.3469 1.00 1.7517 1.6908 1.6721 1.6628 1.6657 1.6580 1.6414 1.6275 1.6147 1.5997 1.5417 1.4577 1.3601 1.05 1.7645 1.7133 1.6858 1.6790 1.6722 1.6645 1.6511 1.6402 1.6289

-1.6164 1.5661 1.4908 1.3993 1.10 1.8426 1.7655 1.7190 1.7084 1.6951 1.6832 1.6704 1.6603 1.6489 1.6375 1.5927 1.5242 1.4384 1.15

.1,9396 1.8462 1.7712 1.7104 1.6939 1.6787 1.,6665 1.6566 1.6446 1.6335 1.5939 1.5344 1.4570 1S0 262 1.9931 1.90-53' 1.8 166 i1.7567" 1.7153 1.6853 I 6755' 1.6637 L.6330' A1.6180 1.5666 196 1.25 2.2044 2.0896 1.9906 1.8822 1.8309 1.7874 1.7567 1.7336 1.7074 1.6788 1.6089 1.5579 1.4935 1.30 2.2908 2.1736 2.0804 1.9906 1.9065 1.8310 1.8001 1.7.783 1.7539 11.7270 1.6593 1.5938 1.5221 1.35 2.56 227..76 202 2.0068 1.9240 1.8784 1.8492 1.8214 1.7901 1.7165 1.6487 156 1.40 2.3546 2.2721 2.1998 2.1244 2.0504 1.9789 1.9263 1.8898 1.8575 1.8239 1.7488 1.6-778 1.6041 1.45 2.3692 2.29-77 2.2273 2.15'75 2.0839 12.0100 i1.9498 11.9067 1.8696 1.8318 1.7530 1.6844 1.6116 1.50 2.3961 2.3315 2.2634 2.1954 2.1216 12.0456 1.9819 1.9350 1.8952 1.8558 1.7746 1.7030 1.6283 1.55 2.4266 2.3770 2.3018 2.2344 2.1592 12.0808 2.0142 1.9639 1.9214

-1.8806 1.7978 1.7238 1.6475 1.60 2.5273 2.5147 2.4527 2.3493 2.2177 12.1236 2.0541 1.9992 11.9492 1.9055 1.8340 1.7595 1.681I9 1.65 1.6054 2.6344 2.5999 2.5061 2.3812 2.2694 2.1984 2.1358 2.0742 2.0353 1.9584 1.8781 1.7872 1.70

.2.5699 2.6109 2.6021 2.5455 2.4460 2.3637 2.3079 2.2471 2.1955 2.1415 2.0585 1.9740 1.8792 1.75 2.4234 2.5144 12.5336 2.4960 2.4712 2.4354 2.3841 2.3264 2.2592 2.1948 2.1122 2.0261 1.9297 1.80 2.4111 2.4978 12.5617 2.6006 2.5992 2.5481 2.4806 2.4215 2.3630 2.3048 2.2032

'2.1143 2.0153 1.85 2.3942 2.4929 2.3586 2.6048 2.6069 2.5713 2.5164 2.4687 2.4162 2.3582 2.2515 2.1622 2.0621 1.90 2.4030 2.5002 2.5667 2.6086 2.6212 12.6041 2.5631 2.5109 2.4555 2.4123 2.3046 2.2111 2.1100 1.95 2.3708 2.4663 2.53 10 2.5840 2.6058 2.5964 2.5618 2.5240 2.4927 2.4537 2.34529 2.2392 2.1377 2.00 2.3184 2.4116 2.4881 2.5412 2.5676 2.5710 2.5758 2.5696 2.5479 2.5129 2.4087 2.2809 2.1606 2.05 2.2979 2.3808 2.4562 2.5187 2.5558 2.5967 2.6167 2.6174 2.6006 2.5700 2.4734 2.3484 2.1960 2.10 1.2307 2.3163 2.3881 2.4572 2.5325 2.5854 2.6098 2.6141 2.6009 2.5744 2.4859 2.3677 2.2195 2.15 2.1628 2.2514 2.3268 2.4173 2.5046 2.5611 2.5880 2.5949 2.5848 2.5623 2.4827 2.3736 2.2336 2.20 2.1077 2.1869 2.2702 2.3703 2.4579 2.5166 2.5467 2.5577 2.5561 2.5508 2.4920 2.3894 2.-i2514 2.25 2.0504 2.1281 2.2170 2.3075 2.3863 2.4570 2.51 80' 2.5602 2.5780 2.5759 2.5206 2.4190 2.2811 2.30 1.9935 2.0798 2.1693 2.2562 2.3256 2.3780 2.4446 2.4917 12.5129 12.5136 12.4638 2.3717 2.2477 2.35 1.9558 2.0543 2.1330 2.2048 2.2799 2.3420 2.3854 2.4086 2.4164 12.4162

1. 2.3955 2.3425 2.2586 2.40 1.9274 2.0268 2.1065 2.1792 2.2424 2.3091 2.3588 2.3883 2.4029 i2.4062 12.3867 2.3607 2.2892 2.50 1.9042 1.9769 12.0518 2.1273 2.1945 2.2541 2.3095 2.3568 2.3938 2.4262 12.4814 2.4946 2.4618 2.60 1.8805 1.9584 12.0264 2.1099 2.1791 2.2406 2.2914 2.3326 2.3949 2.4542 2.5398 2.5799 f2.5751 2.70 1.8074.

1.8761 11.9403 2.0160 2.0870 2.1494 2.2014 12.2501 2.3118 2.3616 2.4251 2.4507 2.4633 2.80 1.7124 1.7561 1.8203 1.8747 1.9470 2.0114 2.0666 2.1214 2.1838 2.2343 2.3013 2.3355 2.3364 2.90 1.7126 1.7468 1.7791 1.8'215 1.8565 1.9146 1.9766 2.033-7

-2.0934 2.1458

-2.2199 2.2900 2.3419 3.00 1.7033 1.7446 1.7728 1.8048 1.8527 1.9019 1.9715 2.0293 2.0731 2.1188 2.2101 2.2867 2.3407 3.10 1.71 87 1.7378 1.7742 1.8020 1.8566 1.9055 1.9554 2.0171 2.0651

.2.1033 2.1770 2.2525 2.3055 3.20 1.6856 1.7113 1.7336 1.7573 1.7986 1.8503 1.8981 1.9373 1.9812 2.0268 2.0978 2.1544 2.2291 3.30 1.6763 1.7098 1.7386 1.7686 1.7994 1.8559 1.9071 1.9481 1.9830 2.0155 2.0774 12.1365 2.2350 3.40 1.6378 1.6756 1.7023 1.7250 1.7493 1.7964 1.8503 11.8914 1.9244 1.9548 2.0080 2.0793 2.1479 3.50 1.5940 1.6320 1.6619 1.6935 1.7279 1.7564 1.8050 1.8471 1.8814 1.9111 1.9566 2.0017 2.0688 3.60 1.5628 1.6049 1.6405 1.6829 1.7179 1.7479 1.7723 1.8135 1.8493 1.8815 1.9335 1.9700 1.9898 3.70 1.5334 1.5830 1.6195 1.6497 1.6783 1.7070 1.7317 1.7523

'1.7824 1.8172 1.8760 1.9187 1.9444 3.80' 1.5042 1.5590 1.6041 1.6424 1.6724 1.6953 1.7118 1.7233 1.7390 1.7589 1.8208 1.8667 1.8969 3.90 1.5154 1.5719 1.6183 1.6592 1.6926 1.7189 1.7379 1.7513 1.7606 1.7683 1.7895 1.8327 1.8677 4.00 1.5184 1.5771 1.6251 1.6684 1.7049 1.7342 1.7558-1.7715 1.7827 1.7920 1.8055 1.8262 1.8494 4.10 1.4978 1.5498 1.5983 1.6428 1.6814 1.7131 1.7367 1.7544 1.7675 1.7783 1.7937 1.8028 1.8219 4.20 1.4509 1.5020 1.5459 1.5866 1.6266 1.6597 1.6849 1.7041 1.7186

-1.7304 1.740 1.7574 1.7635 4.30 1.4081 1.4592 1.5027 1.5432 1.5811 11.6147 1.6409 1.6610 1.6766 1.6892 1.7069 1.7185 1.7230 4.40 1.3762 1.4253 1.4696 1.5104 1.5484 1.5824 1.6092 1.6301 1.6466 1.6600 1.6791 1.6922 I~1.6992 4.50 1.3869_

1.4415

_1.4843 1.5207 1.5521 1.5787 1.5987 I1.6128 1.6261 1.640-7 1.6615 1.6764 1.6862

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 122 of 349 Date: 08/27/03 4.60 1.4024 1.4442 1.4895 1.5290 1.5628 1.5918 1.6140 1.6305 1.6424 1.6516 1.6624

]1.6696 l1.6753 4.70 1.4153 1:4447 1.4677 1.4892 1.5231 1.5534 1.5770 1.5953 1.6094 1.6211 1.6366 1.6472 1.659X 4.80 1.3923 1.4206 1.4428 1.4623 1.4819 1.4977 1.5088 1.5229 1.5385 1.5515 1.5688 1.5796 1.5980 4.90 1.3609 1.3933 1.4193 1.4383 1.4538 1.4658 1.4740 1.4798 1.4917 1.5065 1.52X5 1.5463 1.56S3 5.00 1.3356 1.3721 1.4036 1.428S 1.4483 1.4641 1.4759 1.4846 1.4909 1.4995 1.5098 1.5168 1.5411 5.10 1.3225 1.3577 1.3886 1.4166 1.4393 1.4590 1.4748 1.4871 1.4961 1.5029 1.5190 1.5289 1.5421 5.20 1.3167.-

1.3539 1.3862 1.417' 1.4438 1.4659 1.4836 1.4970 1.5052 1.5139 1.5325 1.5472 1.5629 5.40 1.3512' 1.3917 1.4297 1.4614 1.4832 1.5017 1.5273 1.5488 1.5652 1.5771. --521

'1.6030 '

1:6T3 5.60 1.3239 1.3594 1.4022 1.4397 1.4657 1.4879 1.5102 1.5364 1.5578 1.5745 1.5974 1.6141 1.6291 5.80 1.3483 1.3812 1.4190 1.4516 1.4733 1.4905 1.5072 1.5222 1.5345 1.5525 1.5858 1.6121 1.6337 6.00 1.2552 1.2856 1.3236 1.3560 1.3779 1.3948 1.4117 1.4269 1.4389 1.4504 1.4694 1.4823 1.4907 6.20 1.1873 1.2073 1.2444 1.2769 1.2987 1.3156 1.3324 1.3479 1.3600 1.3717 1.3906 1.4036 1.4141 6.40 1.1832 1.1814 1.1934 1.2152 1.2370 1.2540 1.2709 1.2861 1.2984 1.3100 1.3286 1.3415 1.3607 6.60 1.2156 1.2168 1.2206 1.2238 1.2326 1.2439 1.2543 1.2626 1.2705 1.2821 1.3005 1.3179 1.3467 6.80 1.2405 1.2423 1.2513 1.2585 1.2631 1.2684 1.2774 1.2868 1.2923 1.2949 1.2897 1.2994 1.3311 7.00 1.2752 1.2780 1.2895 1.2979 1.3038 1.3106 1.3217 1.3332 1.3406 1.3449 1.3423 1.3371 1.3582 7.20 1.3031 1.3077 1.3204 1.3302 1.3373 1.3454 1.3581 1.3709 1.3798 1.3853 1.3847 1.3787 1.3873 7.40 1.3191 1.3245 1.3373 1.3477 1.3561 1.3649 1.3784 1.3922 1.4018 1.4083 1.4085 1.4032 1.4124 7.60 1.3542 1.3562 1.3706

.1.3846 1.3942

..1,399.7....-1.4055 1.4202 1.4305 1.4374 1.4383 1.4354 1.4517 7.80 1.3606 1.3638 1.3798 1.3961 1.4075 I.i42' 1.4199 1.4272 1:4352 1.4414 Ti435 1.4586 1.4741.

8.00 1.3330 1.3378 1.3543 1.3710 1.3877 1.3988 1.4069. 1.4183 1.4279 1.4351.

1.4368 1.4319 1.4457 8.50 1.2632 1.2767 1.2994 1.3200 1.3340 1.3443 1.3539 13653 1.3747 1.3819 1.3841 1.3g21 1.3736 9.00 1.2372 1.2551 1.2790 1.3006 1.3169 1.3285 1.3400 1.3528 1.3635 1.3727 1.3785 1.3752 1.3644 9.50 1.3030 1.3130 1.3340 1.3524 1.3697 1.3841 1.3974 1.4122 1.4248 1.4359 1.4454 1.4512 1.4479 10.00 1 1.3238 1.3354 1.3557 1.3752 1.3918 1.4055 1.4189 1.4340 1.4463 1.4578 1.4707 1.4768 1.4743

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 123 of 349 Date: 08/27/03 T.1hl1 a_ avesw i~in fArne arftmhaeri eti

-71?

Per (see)

O.le 0.2g 0.3z 0.4 g 0.5g 0.6p 0.70 9

O.9g 0

l2_

.4i I.fie 0.01 1.4649 1.3085 1.2061 L.0903 0.9983 0.s995 0.7894 0.6946 0.6262 0.5680 0.4699 0.4098 0.3X31 0.03 1.5063 1.3293 1.2214 1.1045 1.0104 0.9103 0.79s8 0.7029 0.6333 0.5744 0.4751 0.4143 0.3874 0.04 1.2661 1.0935 1.0020 0.9052 0.8268 0.7446 0.6531 0.5745 0.5172 0.4690 0.3876 0.3378 0.3159 0.05 1.1144 0.9391 0.8683 0.7846 0.7162 0.6446 0.5653 0.4972 0.4474 0.4055 0.3351 0.2920 0.2730

-0.06 1.0571

-0.9103 0.8040 0.7199 0.6574 0.5912

-Or5181 0.4554 0.4093

-0.3708 0.3061 0.2665 0.2491 0.07 1.0280 0.8113 0.7323 0.6597 0.6024 0.5417 0.4747 0.4174 0.3747 0.3394 0.2801 0.2438 0.2279 0.08 1.0988 0.8167 0.6919 0.6147 0.5673 0.5106 0.447g 0.3939 0.3525 0.3194 0.2634 0.2290 0.2140 0.09 1.1416 0.8483 0.7086 0.6095 0.5586 0.4996 0.4352 0.3513 0.3398 0.3071 0.2530 0.2192 0.2049 0.10 1.2705 0.9260 0.7705 0.6459 0.5623 0.4975 0.4316 0.3767 0.3366 0.3032 0.2480 0.2147 0.2007 0.11 1.3567 0.9378 0.7635 0.6466 0.5605 0.4937 0.4274 0.3725 0.3286 0.2964 0.2433 0.2095 0.1959 0.12 1.4259 0.9867 0.7915 0.6661 0.5750 0.4927 0.4228 0.3674 0.3233 0.2901 0.2390 0.2060 0.1928 0.13 1.5291 0.9977 0.7828 0.6523 0.5584 0.480S 0.4108 0.3577 0.3176 0.2877 0.2366 0.2046 0.1903 0.14 1.5702 1.0837 0.8124 0.6547 0.5545 0.4731 0.4034 0.3529 0.3132 0.2839 0.2330 0.1992 0.1854 0.15 1.5899 1.1728 0.8676 0.6678 0.5653 0.4815 0.4072 0.3565 0.3176 0.2847 0.2324 0.1957 0.1820 0.16 1.7063 1.2098 0.9212 0.7102 0.5818 0.4985 0.4237 0.3650 0.3252 0.2929 0.2376 o.1981

0. 1 825 0.17 1.7882 1.2756 0.9451 0.7492 0.6315 1 0.5403 0.4556 0.3 17 0.3310 1 0.2951 1 0.2417 1 0.2053 0.1857 I 4

I l-.-----4 I

0.3081 w

0.18 1.7754

'"1.319 1.-0216 0.8226 0.6918 l 0.5902

-0:4965 0.4155 0.3508

'0.3081I 0.252091 -- 0.2143 0.1886 1 -

0.19

.1.787S 1.3335 1.0658 0.8848 0.7454 0.6260 0.5230 0.4397 0.3791 0.3318 0.2597 0.2156 0.1940 0.20 1.8847 1.4404 1.1830 0.9889 0.8358 0.7024 0.5892 0.5020 0.4341 0.3774 0.2873 0.2262 0.1927 0.21 1.8514 1.4729 1.2461 1.0522 0.9010 0.7608 0.6361 0.5379 0.4624 0.4023 0.3062 0.2409 0.2003 0.22 1.8409 1.5376 1.2816 1.1031 0.9513 0.S069 0.6764 0.5731 0.4902 0.4226 0.3167 0.2504 0.2172 0.23 1.8428 1.5614 1.3097 1.1335 0.9879 0.8452 0.7105 0.6038 0.5181 0.4472 0.3352 0.2726 0.2342 0.24 1.8441 1.5215 1.3523 1.1590 0.9975 0.8619 0.7331 0.6268 0.5412 0.4706 0.3622 0.2927 0.2492 0.25 1.9435 1.6089 1.3925 1.2171 1.0401 0.8986 0.7673 0.6597 0.5702 0.4974 0.3819 0.3051 0.2582 0.26 2.0133 1.6165 1.3749 1.1913 1.0493 0.9125 0.7804 0.6760 0.5858 0.5128 0.3957 0.3150 0.2619 0.27 2.1266 1.6766 1.4340 1.2339 1.0690 0.9166 0.7774 0.6714 0.5865 0.5182 0.4075 0.3335 0.2786 0.28 2.1871 1.7526 1.4439 1.2259 1.0717 0.9415 0.8089 0.7001 0.6132 0.5431 0.4313 0.3535 0.2975 0.29 2.2114 1.7806 1.4653 1.2495 1.0973 0.9644 0.8305 0.7201 0.6316 0.5605 0.4460 0.3668 0.3099 0.30 2.2532 1.9228 1.5510 1.2939 1.1329 0.9877 0.8522 0.7403 0.6507 0.5788 0.4624 0.3818 0.3247 0.31 2.1725 1.9312 1.5723 1.3184 1.1363 0.9930 0.8616 0.7556 0.6695 0.5920 0.4577 0.3736 0.3193 0.32 2.1209 1.8927 1.5854 1.3510 1.1774 1.0258 0.8927 0.7873 0.7021 0.6226 0.4856 0.3919 0.3250 0.33 2.1604 1.8676 1.5S22 1.4006 1.2290 1.0609 0.9107 0.8005 0.7141 0.6384 0.5035 0.4078 0.3413 0.34 2.2329 1.9185 1.6421 1.4498 1.2812 1.1115 0.9511 0.S274 0.7371 0.6576 0.5196 0.4222 0.3543 0.35 2.2836 1.9788 1.7031 1.4945 1.3296 1.1587 0.9939 0.8662 0.7727 0.6906 0.5408 0.4390 0.3669 0.36 2.1092 1.9549 1.7325 1.5284 1.3711 1.1983 1.0290 0.8980 0.8023 0.7186 0.5644 0.4588 0.3838 0.37 2.0241 1.9942 1.7749 1.5802 1.4228 1.2439 1.0650 0.9255 0.8246 0.7402 0.5843 0.4760 0.4082 0.38 1.9962 2.0623 1.9060 1.6840 1.5121 1.3222 1.1333 0.9859 0.8787

  • 0.7865 0.6200 0.5047 0.4258 0.39 1.9883 2.0963 2.0062 1.7686 1.5669 1 3783 1.1962 1.0503 0.9382 0.8373 0.6441 0.5196 0.4372 0.40 1.8486 1.9904 1.9374 1.8370 1.6535 1.4449 1.2419 1.0884 0.9704 0.8647 0.6640 0.5260 0.4404 0.41 1.7452 1.8767 1.9613 1.8752 1.7190 1.5187 1.3179 1.1562 1.0280 0.9150 0.6970 0.5471 0.4569 0.42 1.6522 1.7888 1.9211 1.9164 1.7820 1.5839 1.3807 1.2159 1.0847 0.9670 0.7348 0.5740 0.4808 0.43 1.5221 1.6569 1.8262 1.8533 1.7400 1.5552 1.3612 1.2027 1.0759 0.9617 0.7349 0.5730 0.4822 0.44 1.5280 1.5852 1.7453 1.8048 1.7439-1.5913 1.4022 1.2390 1.1083 0.9911 0.7609 0.6001 0.5141 0.45 1.5377 1.4725 1.6198 1.7176 1.6969 1.5638 1.4000 1.2530 1.1314 1.0222 0.8085 0.6581 0.5659 0.46 1.5943 1.4514 1.5242 1.6192 1.6424 1.5550 1.4065 1.2671 1.1562 1.0557 0.8474 0.6968 0.5943 0.47 1.5893 1.4447 1.4589 1.5370 1.5765 1.5242 1.3949 1.2683 1.1634 1.0693 0.8791 0.7301 0.6232 0.48 1.6532 1.4439 1.4506 1.4892 1.5267 1.4905 1.3737 1.2616 1.1657 1.0797 0.9084 0.7668 0.6564 0.49 1.6904 1.4720 1.4056 1.4512 1.4895 1.4620 1.3594 1.2498 1.1558 1.0732 0.9047 0.7678 0.6683 0.50 1.6985 1.4837 1.4102 1.4120 1.4262 1.3960 1.3124 1.2155 1.1314 1.0544 0.8992 0.7705 0.6770 0.51 1.7360 1.5004 1.4167 1.4176 1.4277 1.3958 1.3045 1.2075 1.1247 1.0492 0.8998 0.7805 0.6918 0.52 1.7894 1.5444 1.4063 1.3820 1.3893 1.3628 1.2787 1.1846 1.1050 1.0328 0.8895 0.7731 0.6892 0.53 1.8703 1.6174 1.4361 1.3621 1.3612 1.3380 1.2570 1.1667 1.0911 1.0224 0.8864 0.7782 0.7075 0.54 1.9152 1.6486 1.4658 1.3921 1.3617 1.3098 1.2195 1.1347 1.0669 1.0085 0.8954 0.8013 0.7351 0.55 1.9299 1.6532 1.4737 1.3836 1.3561 1.3072 1.2186 1.1351 1.0683 1.0110 0.8995 0.8065 0.7405 0.56 20127 1.7053 1.5123 1.3988 1.3484 1.2983 1.2117 1.1298 1.0648 1.0086 0.9000 0.8089 0.7473 0.57 2 0485 1.7292 1.5540 1.4190 1.3388 1.2691 1.1715 1.0936 1.0320 0.9793 0.8769 0.8014 0.7575 0.58 2.0765 1.7690 1.5758 1.4538 1.3666 1.2778 1.1616 1.0695 1.0154 0.9705 0.8889 0.8186 0.7761 0.60 2.2111 1.9183 1.6439 1.4528 1.3652 1.2900 1.1914 1.0988 1.0291 0.9756 0.8919 0.8392 0.8112 0.62 2.1071 2.0282 1.7702 1.5316 1.3703 1.2689 1.1459 1.0362 0.9663 0.9144 0.8321 0.7852 0.7626 0.64 2.0924 2.0888 1.8534 1.6129 1.4449 1.3107 1.1550 1.0425 0.9592 0.8956 0.8039 0.7492 0.7341 0.66 2.0748 2.1081 1.8875 1.6738 1.5355 1.3942 1.2237 1.0727 0.9626 0.8931 0.7960 0.7488 0.7357 0.68 1.9688 2.0308 1.8743 1 1.7237 1.5937 1.4534 1.2815 1.1242 1.0146 0.9229 0.8002 0.7397 0.7205

Caic Number: GEO.HB[P.03.02 Rev Number: 0 Sheet Number: 124 of' 349

______D ate: 08/27/03 0.70 1.8280 1.9047 L

18602 )1.776R 1.6616 1.5082 1.3138 11.1527 1.0332 0.938 0.1013 10.7365 J 0.7233 0.72 1.7478 1.8236 1.8402 1.7851 1.6714 1.5236 1.3272 11.1619 1.0431 0.9492 j0.8060 10.7132 0.6909 0.74 1.7010 1.7935 1.8139 1.7615 11.6566 1.5269 1.3407 1.1817 1.0596 0.9637 0.8201 0.7216 0.6753 0.76 1.6965 1.732.5 1I.7287 1.6990 1.6239 1.5269 1.3759 1.2204 1.0867 0.9760 0.8290 0.7328 0.68409 0.78 1.6675 1.7040 1.6972 1.6648 1.6418 1.5787 1.4371 1.2720 1.1354 1.0340 0.8593 0.7450 0.6790 0.80 1.6354 1.6806 1.6781 1.6806 1.6687 1.6093 1.4702 1.3022 1.1612 1.0594 0.8841 0.7677 0.6978 0.8-2

.1.6161 1.6742

-. 6.829 1.6960 1.6909 1.6357 1.4991 1-3304 1.2019 1.0925 0.9161 0.7962 0.7237 0.84 1.5715 1.6227 1.6429 1.6609 1.6661 1.6157 1.5063 1-3827 1.2607.

1. 1468 0.9597 0.8336.j"0.7570~--

0.86 1.5384 1.5755 1.5948 1.6344 1.6461 1.6111 1.5148 1.3909 1.2682 1.1545 0.9704 0.8420 10.7656 0.88 1.5308 1.5365 1.5584 1.6021 1.6179 1.5875 1.4949 1.3739 1.2553 1.1467 0.9784 0.8459 0.7711 0.90 1.5449 1.5110 1.5233 1.5688 1.5862 1.5590 1.4712 1.3577 1.2481 1.1521 0.9963 0J.8s63 9 0.7842 0.92 1.5477 1.5041 1.4856 1.5324 1.5520 1.5293 1.4513 1.3506 1.2642 1.1825 1.0183 10. 88R48 0.7963 0.94 11.5706 11.5265 1.4878 1.4991 1.5226 1.5074 1.4601 1.4025 11.3293 1.2447 11.0588 0.8993 0.8066 0.96 1.5770 1.5415 1.5062 1.5151 1.5193 1.5138 1.4834 1.4259 1.3519 1.2657 11.0771 10.9112 0.8 05 8 0.98 1.5751 1.5454 1.5115 1.5207 1.5266 1.5209 1.4897 1.4321 1.3582 1.-2752 1.0909 10.9246 0.8162 1.00 1.5604 1.5320 1.5019 1.5140 1.5138 1.5024 1.4710 1.4233 1.3657 1.2948 1.1076 0.9350 0.8228 1.05 1.6348 1.5532 1.5049 1.5018 1.5027 1.4955 1.64 1.4219 1.3695 1.3118 1.1704 1.0164 0.9057 1.10 1.7574 1.6153 1.5257 1.5062 1.4892 1.4590 1.4133 1.3724 1.3318 1.2910 1.1904 1.0863 0.9904 1U1 '. -.1.8941 1.7463--.

1-6465 1.5897 1.5426

.1.5014 1.465.6.

1,4280 1.3910 1.3565,-

1.2688 1.1638, 1.0697 1.20 2.0553 1.9280 1.8179 1.7312 1.6477 1.5567 1.4714 1j.4170 1.3804 1.3442 1.2674 1.1783-1 1.1171 1.25 2.1168

-2.0038 1.8972 1.8088 1.7227 1.6258 1.5225 1.4332 1.3598 1.3023 1.2275 1.1742 11.1430 1.30 2.1666 2.0587 1.9642 1.8879 1.8121 1.7209 1.6172 1.5244 1.4461 1.3802 1.2832 1.2328 11.2099 1.35 2.4261 2.2480 2.1113 1.9987 1.9078 1.8064 1.6884 1.5801 1.4883 1.4141 1.3153 1.2561 1.2267 1.40 2.5267 2.3633 2.1666 2.0307 1.9335 1.8259 1.7033 1.5924 1.5011 1.4266 1.3144 1.2397 1.1903 1.45 2.5667 2.4529 2.2914 2.1197 1.9873 1.8606 1.7165 1.5948 1.5008 1.4232 11.3078 1.2315 1.1812 1.50 2.5332 2.4411 12.2897 2.1566 2.0457 1.9156 !1.7666 11.6425 1.5428 1.4656 1.3313 1.2494 1.2045 1.55 2.4714 2.4365 2.3387 2.2359 2.1317 2.0021 1.8495 1.7058 1.5829 1.4960 1.3663 1.2721 1.2141 1.60 2.5541 2.5429 2.4412 2.3146 2.1910 2.0619 1.9082 1.7616 1.6348 1.5366 1.3956 1.2967 11.2296 1.65 2.6892 2.7120 2.6166 2.4627 2.3056 2.1269 1.9718 1.8228 1.6905 1.5921 1.4457 1.3455 11.2774 1.70 2.6906 2.7303 2.6498 2.5215 2.3701 2.2183 2.0582 1.9085 1.7757 1.6679 1.4985 1.3853 11.3095 1.75 2.5984 2.6660 2.6330 2.5377 2.4170

-2.2771 2.1054 1.9517 1.8242 1.7109 1.5338 1.4169 11.3389 1.80 2.5712 2.6608 2.6656 2.6104 2.5058 2.3540 2.1875 2.0316 1.9010 1.7787 11.5889 1.4659 11.3848 1.85 2.5364 2.6423 2.6581 2.6087 2.5296 2.4035 2.2442 2.0950 1.9641 1.8391 11.6320 1.4944 11.4130 1.90 2.5 112 2.6381 2.6808 2.6584 2.5809 2.4496 2.3196 2.1902 -2.0572 1.9396 1.7306 1.5826 11.4866 1.95 2.4599 2.5745 2.6205 2.6042 2.5594 2.4973 2.4053 2.2929 2.1631 2.0334 1.8157

.1.6611 1.5645 2.00 2.2814 2.3979 2.4561 2.5081 2.5365 2.5116 2.4317 2.3188 2.1885 2.0514 1.8454 1.7096 1.6171 2.05 2.2489 2.3900 2.5089 2.5785 2.5898 2.5529 2.4634 2.3395 2.2099 2.0900 1.8823 11.7469 1.6570 2.10 2.2297 2.3744 2.4893 2.5680 2.5940 2.5590 2.4538 2.3457 2.2626 2.1644 1.9573 1.7824 1.6905 2.15 2.1856 2.2994 2.3925 2.4621 2.4910 2.4719 2.4453 2.4067 2.3346 2.2378 I2.01I80 1.8545 1.7452 2.20 2.1658 2.2749 2.3591 2.4215 2.4566 2.4991 12.5024 2.4656 2.3947 2.2982 12.0848 1.91'76 11.8094 2.25 2.1255 2.2434 2.3332 2.4010 2.4697 2.5187 2.5237 2.5103 2.4616

-2.3801 12.1712 1.9845 11.8671 2.30 2.0503 2.1749 2.2713 2.3508 2.4351 2.4847 2.4988 2.4875 2.4376 2.3579 12.1593 1.9955 1.8938 2.35 1.9802 2.1119 2.2184 2.3106 2.3949 2.4453 2.4537 2.4258 2.3772 2.3133 12.1697 2.0339 1.9351 2.40 1.9121 2.0551 2.1705 2.261 8 2.3464 2.3990 2.4188 2.4152 2.3860 2.3362 2.2000 2.0803 1.9830 2.50 1.8021 1.9463 2.0671 2.1601 2.2267 2.2953 2.3358 2.3452 2.3302 2.2989 2.1987 2.0919 2.0001 2.60 1.1135 1.9553 2.0745 2.1758 2.2581 2.3260 2.3780 2.4096 2.4178 2.4033 2.3192 2.2007 2.0834 2.70 1.7221 1.8303 1.9589 2.0706 2.1629 2.2428 2.3084 2.3522 2.3708 2.3656 2.3170 2.2465 12.1554 2.80 1.6521 1.7516 11.8454 1.9497 2.0376 2.1160 2.1843 2.2364 2.2688 2.2821 2.2817 2.2346 12.1705 2.90 1.5773 1.6409 1.73075 1.7788 1.8471 1.9180 1.9746 2.0263 2.0738 2.1258 2.2289 2.2803 12.2585 3.00 1.5626 1.6192 11.6787 1.7468 1.8130 1.8751 1.9271 1.9638 2.014-2 2.0775 2.2074 2.2679 12.2623 3.10 1.5923 1.6425 1.6804 1.7307 1.7932 1.8564 1.9134 1.9604 2.0265 2.0943 2.2200 2.3091 12.3516 3.20 1.5946 1.6522 1.6973 1.7412 1.7921 1.8538 1.9228 2.0061 2.0767 2.1352 2.2395 2.3244 12.3730 3.30 1.5852 1.6427 1.6945 1.7518 1.8110 1.8712 1.9368 12.0100 2.0830 2.1430 2.2340 2.3201 2.3692 3.40 1.6897 1.7524 1.8097 1.8689 1.9250 1.9855 2.0433 12.0935 2.1340 2.1732 2.2887 12.3899 2.4730 3.50 1.7449 1.8216 1.8892 1.9581 2.0250 2.0893 2.1491 2.2022 2.2503 2.2903 2.3759 12.4727 2.5566 3.60 1.7060 1.7774 1.8435 1.9145 1.9877 2.0616 2.1327 2.1958 2.2485 2.2930 2.3843 2.4607 2.5449 3.70 1.5707 1.6479 1.7163 1.7829 1.8412 1.8945 1.9555 2.0173 2.0701 2.1156 2.2037 2.2842 2.3630 3.80 1.4805 1.5581 1.6252 1.6836 1.7313 1.7719 1.8091 1.8465 1.8934 1.9383 2.0309 2.1350 2.2110 3.90 1.4215 1.5014 1.5709 1.6330 1.6848 1.7310 1.7779 1.8198 1.8554 1.8870 1.9561

-2.0683 2.1543 4.00 1.3841 1.4400 1.5126 1.5803 1.6391 1.6985 1.7548 1.8045 1.8475 1.8863 1.9565 2.0523 2.1440 4.10 1.3624 1.4081 1.4566 1.5035 1.5611 1.6278 1.6937 1.7519 1.8013.

1.8452 1.9225 2.0220 2.1020 4.20 1.2829 1.3332 1.3695 1.4373 1.50S2 1.5694 1.6287 1.6768 1.7236 1.7700 1.8624 1.9663 12.0462 4.30 1.3228 1.3626 11.4052 1.4675 1.5296 1.5879 1.6425 1.6873 11.7218 1.7553 1.8427 1.9546 2.0548 4.40 1.3121 11.3355 1.3699 1.4270 1.82 1.5489 1.6064 1.6556 1.6951 1.7278 1.8070 1.9145 2.0147 4.50 1.2948.

1.3077.11.3213 1.3610 11.4119 1.4647 1.5198 1.5712 1.6169 1.6590 1.7401 1.8437 1.9365

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 125 of 349 Date: 08/27/03 I

4.60 1 1.2842 1 1.3077 1 1.33611 1362s 1 1.3842 1 i.4161 1 1.4724 1 1.5230 1 1.5700 1 1.6129 l 1.6923 1 1.7665 I1.32 1 4.70 1.3433 1.3769 1.4110 1.4401 1.4628 1.4126 1.5096 1.5453 1.5777 1.6231 1.7124 1.7911 1IS77 4.80 1.3856 1.4172 1.4458 1.4701 1.4876 1.5132 1.5583 1.5988 1.6330 1.6613 1.7240 1.8114 1.8806 l 4.90 1.3846 1.4185 1.4494 1.4767 1.4966 1.5115 1.5457 1.5884 1.6250 1.6561 1.7120 1.7604 1.8148 5.00 1.3710 1.4112 1.4477 1.4800 1.5047 1.5246 1.5428 1.5832 1.6237 1.6587 1.7210 1.7747 1.8184 5.10 1.3854 1.4278 1.4684 1.5044 1.5328 1.5570 1.5799 1.6025 1.6410 1.6800 1.7488 1.8079 1.8562

.5.20

---. 31.9..

1.4293 1.4773 1.5211 1.5568 1.5898 1.6236 1.657

. 1.6890 1.7188 1.7760 1.8310 1.8790 5.40 1.4028 1.4549 1.5090 1.5611 1.6056 1.6469 1.6878 1.7278 1.7650 1.8006 1.8697 1.9362 1.9960 5.60 1.2294 1.2355 1.2667 1.2988 1.3410 1.3863 1.4316 1.4754 1.5163 1.5559 1.6319 1.7045 1.7701 5.80 1.2324 1.2426 1.2558 1.2722 1.2891 1.3049 1.3158 1.3241 1.3323 1.3510 1.3964 1.4380 1.4990 6.00 1.2254 1.2436 1.2606 1.2799 1.2986 1.3168 1.3328 1.3461 1.3584 1.3720 1.4039 1.4381 1.4673 6.20 1.2052 1.2231 1.2334 1.2555 1.2777 1.3005 1.3247 1.3456 1.3634 1.3810 1.4178 1.4542 1.4844 6.40 1.2238 1.2472 1.2630 1.2741 1.2855 1.2985 1.3118 1.3250 1.3394 1.3545

.1.3852 1.4136 1.4386 6.60 1.1729 1.1871 1.2071 1.2245 1.2425 1.2679 1.2909 1.3094 1.3240 1.3370 1.3648 1.3948 1.4221 6.80 1.1378 1.1565 1.1724 1.1861 1.2050 1.2271 1.2531 1.2744 1.2916 1.3070 1.3394 1.3731 1.4036 7.00 1.1557 1.1764 1.1988 1.2197 1.2373 1.2530 1.2657 1.2785 1.2980 1.3198 1.3633 1.4024 1.4355 7.20 1.1688 1.1899 1.2092 1.2279 1.2441 1.2597 1.2739 1.2879 1.3021 1.3154 1.3642 1.4115

. 1.4523 7.40 1.1615 1.1663 1.1671 1.1806 1.1977 1.2169 1.2369 1.2542 1.2672 1.2758 1.2968 1.3304 1.3611 7.60 1.17-140-..

1848 1.190L.4L-298 1.1860

-1.2007.-

1.2143 1.2254.-.1.2371 1.2490 1.2793 1.3105 1.3354 7.80 1.1549 1.1726 1.1848 1.1890 1.1876 1.1923 1.2051 1.2171 1.2304 1.2453 1.2823 1.3194 1.3508 8.00 1.1174 1.1292 1.1418 1.1475 1.1604 1.1750 1.1887

_1.2013 1.2148 1.2300 1.2678 1.3059 1.3390 8.50 1.1070 1.1108 1.1179 7 1.1249 1.1301 1.1328 1.1328 1.1340 1.1334 1.1376 1.1468 1.184S 0.8076 9.00 1.1513 1.1637 1.1792 1.1942 1.2065 1.2167 1.2257 1.2334 1.2396 1.2445 1.2501 1.2570 0.7977 9.50 1.2166 1.2304 1.2459 1.2584 1.2659 1.2717 1.2789 1.2868 1.2928 1.2963 1.2989 1.3042 0.8196 10.00 1.2207 1.2533 1.2854 1.3071 1.3204 1.3298 1.3398 1.3512 1.3620 1 1.3717 1.3863 1.3967 0.868S 2

F.I.

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 126 of 349 Date: 08/27/03 Tabl. 9i O. A;e n

f f...

the

,.nner

.0a Profied fl (see)

D~~~lg 0.2g 0.3gz 0.4g 0.5g 0.6g 0.7g O.Sgz 0.9g I.Og 1.2g 1.4g

.6 0.01 1.7674 1.6451 1.5553 1.5064 1.4744 1.4269 1.3609 1.2937 1.2312 1.1727 1.0778 1.0001 0.9234 0.03 2.0233 1.8699 1.7308 1.6684 1.6271 1.5709 1.4948 1.4181 1.3460 1.2793 1.1707 1.0850 1.0009 0.04 1.9212 1.7693 1.6131 1.5378 1.4908 1.4339 1.3593 1.2868 1.2182 1.1547 1.0510 0.9727 0.8958 o.m5 1.8849 1.7409 1.5494 1.469..

1.4184 1.3624 1.2881 1.2134 1.1429 1.0826 0.9793 0.9042 0.8322 0.06 1.9982 1.7568 1.5198 1.405_

I.3482 1.2845 1.2105 1.1339 1.0619 1.0014 0.9048 0.8251 0.7577' 0.07 2.0195 1.7347 1.5003 1.3470 1.2822 1.2272 1.1549 1.0966 1.0344 0.9752 0.8785 0.7922 0.7159 0.08 2.0415 1.8689 1.6961 1.5408 1.4262 1.3511 1.2663 1.1724 1.0892 1.0173 0.9048 0.8151 0.7370 0.09 2.0455 1.8596 1.6985 1.5483 1.4324 1.3223 1.2213 1.1282 1.0419 0.9745 0.8654 0.7792 0.7068 0.10 2.0986 1.9066 1.7077 1.5452 1.4137 1.2973 1.2069 1.1176 1.0250 0.94S7 0.8395 0.7670 0.6981 0.11 2.3431 2.1892 1.9758 1.7955 1.6584 1.5445 1.4312 1.3250 1.2161 1.1178 0.9633 0.8390 0.7484 0.12 2.2636 2.1650 1.9581 1.8286 1.7009 1.5760 1.4793 1.3826 1.2802 1.1895 1.031.3 0.9035 0.8001 0.13 2.3303 2.1930 2.0325 1.8883 1.7927 1.7011 1.6073 1.5017 1.3981 1.3023 1.1347 0.9972 0.8859 0.14 2.2635 2.1502 2.0388 1.S979 1.7718 1.6509 1.5609 1.4814 1.3943 1.3090 1.1554 1.0249 0.9145 0.15 2.1773 1.9823 1.8769 1.7745 1.6563 1.5207 1.3891 1.2957 1.2218 1.1546 1.0293 0.9293 0.8503 0.16 1 2.5476 2.2208 1.9939 1.8256 1.6831 1.5481 1.4372 1.3463 1.2632 1.1936 1.0742 0.9735 0.9050 I.,...1 17 I 9141

. i 5Rl I 1

"n'R ASAMM I R.LV7 I.6s7 I 5S24 1 4624

1. I7R27J 1 3189 1[2166 1.1121 1.0221

[. ~,

AI1R 2.,7S72 I.12 2 49 21335 1I Q13 I I R.i0 I A7l"1 1 5440 1 4265 11.474 1.2110 1.0907 0.9845 0.19 2.6752 2.5592 2.4741 2.3640 2.2442 2.1080 1.9531 1.S108 1.6846 1.5850 1.4201 1.27R6 1.1619-0.20 2.6021 2.4836 2.4434 2.4190 2.3290 2.1777 2.0285 1.8926 1.7709 1.6748 1.5287 1.4043 1.2960 0.21 2.6127 2.5001 2.4241 2.3898 2.3298 2.2477 2.1360 2.0309 1.9215 1.815 1.6330 1.466S 1.3364 0.22 2.5492 2.4720 2.3894 2.3317 2.2846 2.2312 2.1554 2.0596 1.9580 1.861S 1.6874 1.5282 1.4146 0.23 2.3S39 T2.3434 2.2837 2.2780 2.2483 2.1873 2.1094 2.0322 1.9540 1.8852 1.7663 1.6494 1.5341 0.24 2.2008 2.2135 2.2197 2.2288 2.2215 2.1804 2.1190 2.0494 1.9793 1.9127 1.7938 1.6778 1.5653 0.25 2.1728 2.1911 2.2050 2.2261 2.2329 2.2045 2.1511 2.0869 2.0174 1.9495 1.8312 1.7166 1.6085 0.26 2.1212 2.1370 2.1509 2.1716 2.1946 2.1930 2.1629 2.1228 2.0703 2.0175 1.9084 1.7973 1.6956 0.27 1.9612 1.9763 2.0120 2.0622 2.1030 2.1163 2.1194 2.1022 2.0724 2.0328 1.9591 1.8673 1.7623 0.28 18.757 1.8601 1.8590 1.8754 1.9175 1.9531 1.9694 1.9674 1.9510 1.9259 1.8650 1.7912 1.7086 0.29 1.8128 1.7830 1.7502 1.7555 1.7968 1.8286 1.8422 1.8433 1.8312 1.8119 17800 1.7233 1.6531 0.30 1.9011 1.7785 1.6988 1.6742 1.7022 1.7314 1.745S 1.7476 1.7361 1.7276 1.7130 1.6753 1.6303 0.31 2.0073 1.8807 1.7663 1.6893 1,6769 1.6957 1.7055 1.7026 I.6588 1.6677 1.6220 1.6033 1.5674 0.32 2.1334 1.9988 1.S764 1.7852 1.7213 1.6748 1.6817 1.6795 1.6666 1.6476 1.6198 1.6036 1.5729 033 2.3053 2.1618 2.0284 1.9304 1.8551 1.7863 1.7245 1.6706 1.6620 1.6479 1.6270 1.6151 1.5897 0.34 2.3342 2.1833 2.0449 1.9481 1.8749 1.7989 1.7354 1.6729 1.6116 1.5587 1.5004 1.4930 1.4744 0.35 2.3740 2.2212 2.0827 1.9719 1.8866 1.8164 1.7520 1.6861 1.6221 1.5684 1.4898 1.4495 1.4261 0.36 2.5534 2.4357 2.2777 2.1369 2.0378 1.9323 1.8350 1.7407 1.6559 1.5878 1.5109 1.4623 1.4301 0.37 2.5845 2.4663 2.3096 2.1721 2.0643 1.9617 1.8704 1.7872 1.7060 1.6301 1.5199 1.4444 1.3903 0.38 2.5654 2.4913 2.3826 2.2718 2.1727 2.0719 1.9655 1.8559 1.7477 1.6587 1.5434 1.4555 1.3S72 0.39 2.4517 2.4332 2.3605 2.2815 2.2031 2.1075 2.0063 1.9021 1.7961 1.6954 1.5312 1.4421 1.36S3 0.40 2.4067 2.4126 2.3658

.2.3078 2.2430 2.1557 2.0559 1.9528 1.8480 1.7446 1.5792 1.4616 1.3830 0.41 2.3800 2.4082 2.3804 2.3329 2.2762 2.1947 2.0987 1.9962 1.8912 1.7930 1.6290 1.4969 1.4152 0.42 2.3263 2.3679 2.3516 2.3373 2.3020 2.2268 2.1366 2.0342 1.9367 1.8523 1.6982 1.5819 1.4858 0.43 2.2044 2.2790 2.3125 2.3479 2.3576 2.3111 2.2216 2.1082 1.9948 1.8936 1.7184 1.5984 1.5042 0.44' 2.1622 2.2464 23011 2.3445 2.3570 2.3310 2.2693 2.1810 2.0721 1.9630 1.7827 1.6519 1.5474 0.45 2.0449 2.0776 2.1419 2.1859 2.2164 2.2076 2.1602 2.0848 1.9978 1.9251 1.7936 1.6767 1.5916 0.46 1.9747 2.0412 2.0716 2.0908 2.1087 2.1034 2.0805 2.0452 1.9948 1.9444 1.8347 1.7237 1.6189 0.47 1.9206 1.9993 2.0422 2.0712 2.0967 2.0979 2.0768 2.0482 2.0059 1.9553 1.8460 1.7380 1.6327 0.48 1.8689 1.9485 2.0012 2.0391 2.0729 2.0820 2.0746 2.0506 2.0115 1.9655 1.8643 1.7633 1.6611 0.49 1.8416 1.8841 1.9451 1.9923 2.0357 2.0578 2.0570 2.0392 2.0074 1.9672 1.8766 1.7831 1.6847 0.50 1.8305 1.8754 1.8998 1.9533 2.0035 2.0330 2.0402 2.0305 2.0053 1.9710 1;8895 1.8003 1.7106 0.51 1.8024 1.8527 1.8804 1.9055 1.9508 1.9876 2.0031 2.0000 1.9815 1.9517 1.8767 1.7934 1.7202 0.52 1.7520 1.7849 1.8041 1.8250 1.8474 1.8611 1.8748 1.8777 1.8641 1.8384 1.7863 1.7486 1.7097 0.53 1.7450 1.7788 1.8003 1.8229 1.8478 1.8608 1.8610 1.8537 1.8398 1.8262 1.8076 1.7870 1.7458 0.54 1.7357 1.7703 1.7926 1.8166 1.8435 1.8581 1.8603 1.8544 1.8416 1.8308 1.8210 1.8041 1.7690 0.55 1.7145 1.7463 1.7692 1.7939 1.8222 1.8386 1.8428 1.8389 1.8275-1.8124 1.8013 1.7847 1.7533 0.56 1.7107 1.7404 1.7541 1.7679 1.7966 1.8147 1.8213 1.8193 1.8097 1.7962 1.7664 1.7435 1.7153 0.57 1.7049 1.7350 1.7501 1.7645 1.7837 1.7965 1.8053 1.8058 1.7985 1.7868 1.7675 1.7458 1.7140 0.58 1.6942 1.7236 1.7394 1.7556 1.7759 1.7867 1.7888 1.7888 1.7863 1.7824 1.7672 1.7480 1.7187 0.60 1.6728 1.7013 1.7192 1.7378 1.7619 1.7766 1.7822 1.7852 1.7847 1.7826 1.7723 1.7580 1.7336 0.62 1.6596 1.6806 1.6931 1.7073 1.7272 1.7418 1.7500 1.7561 1.7579 1.7565 1.7470 1.7361 1.7181 0.64 1.6385 1.6515 1.6634 1.6783 1.6996 1.7162 1.7275 1.7363 1.7407 1.7420 1.7371 1.7302 1.7164 0.66 1.6947 1.6825 1.6631 1.6489 1.6681 1.6861 1.6998 1.7113 1.7187 1.7225 1.7234 1.7212 1.7126 0.68 1.6905

-1.6865 1.6777 1.6729 1 1.6742 1.6714 1.6641 1.6564 1.6468 1.6474 1.6552 1.6604 1.6593

Calc Number: GEO.HB[P.03.027 Rev Number: 0 Sheet Number: 127 of 3 )49 Date: 08/27/0-3 0.70 1 1.9738 1 1.8204 L 1.7696 1.7213 I1.7093 1.6991 1 1.6810 1 1.6733 1 1.6680 1.66'23 1 L.6490 1 1.639X 1.6529S1 1-->

0.72

-2.051-2

-2.0003 1.9552 1.9111

1. 759 1.8370 1.7942 1.7560 1.7302 1.7065 1.6653 1.6437 1UMN9 0.74 10892 2.0501 2.0098 1.9721 1.9424 1.9076 1.8673 1.8262 1.7836 1.7446 1.6890 1.6548 1.6243 0.76 2.1600 2.1383 I 1 073 2.0794 2.0613 2.0375 2.0070 1.9727 1.9335 1.8954 1.8290 1.77?5 1.7353 0.78 2.1767 2.1560 2.1255 2.1011 2.0358 2.0651 2.0371 2.0055 1.9606-F-1.9329 I.M92 1.8194 1.7790 0.80 2.22?8 2.1628

').1 162 2.0909 2.0794 i.0602 2.0350 10061 1.9737 1.9435 1.8862 1.8155 1.7900 0.87c-2,3669.

2-1.952 2.1444 2,1142,.

2.0835 2-0616 2.0378 2.0089 1.9798 1.9254 1.8781 1.83.36

0. 84 2.4744 2.3991 2.3034 2.2315 2.2002 2.1672 2.1349 2.1034 2.008 2.'016 1.9538 1.80trt -- l'.8580 0.86 2.5173 2.4464 3

2.2433 2.2225 2.1974 2.1668 2.1313 2.0952 2.0255 1.9628 1.9024

0. 98 2.5636 2.5000 2.4115 2.3524 2.3387 2.3237 2.3017 2.2746 2.2392 2.2011 2-1240 2.0533 1.9.975 0.90 2.5844 2.5429 2.4948 2.4331 2.4169 2.4019 2.3816 2.3570 2.3249 2.2898 2.2176 2.1499 2.0951 0.92 2.5852 2.5621 2.5217 2.4779 2.4449 2.4298 2.4108 2.3885 2.3594 2.3276 2.2619 2.1985 2.1367 0.94 2.5531 2.5434 2.5139 2.4791 2.4474 2.4183 2.4006 2.3800 2.3535 2.3247 2.2647 2.2o66 2-106 0.96 2.5350 2.5323 2.5113 2.4843 2.4582 2.4267 2.3949 2.3761 12.3514 2.3246 12 2693 2.2154

!.! 62 0.98 2.5307 2.5297 2.5137 2.4926 2.4712 2.4435 2.4091 2.3752 12.3522 1.3274 2.2759 2.2257 1.00 2.5357 2.5473 2.5405 2.5239 2.5052 2.4752 2.4326 2.3944 2.3563 2.3330 2.2850 2.2382 2.1900 1.05 2.5994 2.6144 2.6122 2.6043 2.5966 2.5781 2.5455 2-5038 2.4546 2.4035 2.3233 2.2828 2.2407 1.10 2.6239 2.6557 2.6962 2.7282 2.7468

').7515 2.7393 2.7174 2.6927 2.6418

'2.5511 2.4545 2.3592

.1. L5 I., 2.6455 2,7103 2.736.9..

7JR46

-,-,2.8157 2.8125 2.7953 2.7663 2.7322 2.6485 2.5579 2.4689 1.20 2.5835 2,6372 2.6788 2.7266 2.7719 2.9064 2.8262 2.9320 2.9252 2.8089 2.7635 2.763 2.6415 Ll 5 2.4923 2.5673 2.6251 2.6778 2.7274 2.7677 2.7955 2.8114 2.8163

-2.8122 2.7899 2.7558 2.7064 1.30 2.3989 2.4533 2.4968 2.5436 2.5891 2.6287 2.6592

-2.6823 2.6984 2.7073 2.7079 2.6907 2.6594 1.35 23084 2.3608 2.4002 2.4356 2.4661 2.4930 2.5155 2.5349 2.5549 2.5760 2.6061 2.6197 2.6169 1.40 2.2387 2.2903 2.3293 2.3652 2.3967 2.4246 2.4566 2.4909 2.5226 2.5601 2.6156 2.6490 2.6612 1.45 2.1206 2.1666 2.2077 2.2309 2.2868 2.3209 2.3527 2.3968 2.4268 2.4643 2.5311 2.578'7 2.6090 1.50 2.0752 2.1320 2.1898 2.2382 2.2772 2.3141 2.3522 2.3996 2.4442 2.4847 2.5540 2.6092 2.6504 1.55 2.0535 2.0958 2.1411 2.1841 2.2741 2.2641 2.3045 2.3550 2.4028 1 2.4463 2.5215 2,5869 2.6392 1.60 2.0105 2.0502 2.0879 2.1292 2.1711 2.2109 2.2489 2.2860 2.3331 2.3817 2.4640 2.5312 2.5844 1.65 1.9755 2.0227 2.0653 2.1037 2.1388 2.1805 2.2200 2.2566 2.2926 2.3266 2.4049 2.4730 2.5281 1.70 L9727 2.0143 2.0526 2.0864 2.1227 2.1558 2.1938 2.2319 2.2687 2.3028 2.3640 2.4204 2,4908 1.75 1,9637 2.0086 2.0491 2.0837 2.1144 2.1430 2.1699 2.1945 2.2237 2.2551 2.3127 23634 14106 1.80 1.9263 2.0212 2.0622 2.0993 2.1322 2.1635 2.1918 2.2185 2,2423 1 2.2810 2.3195 2.3464 1.85 1.8789 1.9296 1.9775 2.0205 2.0586 2.0943 1 2.1274 1 2.1574

2. I 859 2.2112 1 2.2531 2.2840 2.3064 1.90 1.8461 1.8894 1.9393 1.9850 2.0258 2.0641 2.0996 2.1320 2.1629 2.1904 2.2364

-'2.2711 2.2969 1.95 1.8184 1.8619 1.9008 1.9375 1.9709 2.0040 2.0418 2.0763 2.1091 2.1384 2.1974 2.2252 2.2539 2.00 1.7971 1.9380 1.9773 1.9149 1.9495 1.9811 2.0089 2.0336 2.0570 2.0881 2.1402 2.1812 2.2131 2.05 1.759 1.7953 1.8302 1.8662 1.9015 1.9339 1.9625 1.9892 2.0123 2.0341 2.0712 2.1091 2.1440 2.10 1,7393 1.7753 1.8102 1.8431 1.9732 1.9001 1.9234 1.9441 1.9632 1.9815 2.0203 2.0508 2.0737 2.15 1.7256 1.7615 1.7965 1.9298 1.8606 1.8885 1.9125 1.9339 1.9537. 1.9710 1-.9991 10183 2.0352 2.20 1.7168 1.7529 1.7893 1.9222 1.8537 1.8923 1.9073 1.9292 1.9498 1.9678 1.9972 2.0179 2.0315 2.25 1.6958 1.7319 1.7674 1.8015 1.9335 1.8626 1.8880 1.9105 1.9315 1.9501 1.9804 2.0021 2.0168 2.30 1.6534 1.6810 1.7080 1.7405 1.7720 1.8010 1.8264 1.8490 1.8700 1.8887 1.9196 1.9424 1.9680 2.35 1.6404 1.6700 1.6991 1.7277 1.7547 1.7802 1.8043 1.8275 1.8513 1.8739 1.9143 1.9479 1.9757 2.40 1.6398 1.6686 1.6962 1.7'216 1.7462 1.7705 1.7936 1.8159 1.8380 1.8617 1.9042 1.9401 1.9704 2.50 1.5603 1.5853 1.6113 1.6390 1.6635 1.6927 1.7183 1.7416 1.7638 1.7841 1-.8186 1.8465 1.8802 2.60 1.5216 1.5399 1.5568 1.5758 1.5993 1.6217 1.6437 I:6648 1.6859 1.7061 1.7437 1.7763 1.8039 2.70 1.5332 1.5552 1.5763 1.5983 1.6193 1.6392 1-6569 1.6-730 1.6893 1.7020 1.7-289 1.7620 1.7907 2.80 1,5158 1.5368 1.5591 1.5828 1.6059 1.6280 1.6484 1.6672 1.6851 1.7012 1.7296 1.7509 1.7694 2.90 1.4?41 1.4971 1.5179 1.5393 1.5564 1.5728 1.5871 1.5996 1.6114 1.6224 1.6454 1.6699 1.6902 3.00 1.4399 1.4589 1.4810 1.5024 1.5209 1.5381 1.5535 1.5671 1.5802 1.5922 1.6136 1.6311 1.6450 3.10 1.4339 1.4470 1.4577 1.4752 1.4947 1.5125 1.5287 1.3435 1.5576 1.5706 1.5939 1.6132 1.6289 3.20 1.4284 1.4447 1.4631 1.4215 1.4975 1.5126 1.5271 1.5409 1.5541 1.5664 1.5885 1.6065 1.6214 3.30 1.4263 1.4455 1.4653 1.4850 1.5023 1.5188 1.5344 1.5491 1.5636 1.5770 1.6010 1.6207 1.6367 3.40 1.4005 1.4177 1.4333 1.4518 1.4704 1.4877 1.5042 1.5201 1.5356 1.5499 1.5790 1.6081 1.6324 3.50 1.4070 1.4173 1.4251

'1.4346 1.4434 1 1.456D 1.4675 1.4842 1.5006 1.5158 1.5428 1.5-714 1.5984 3.60 1.4166 1.4315 1.4438 1.4553 1.4649 1.4738 1.4847 1.4972 1 1.5100 1.5222 1.5449 1,5646 1.5212 3.70 1.4052 1.4136 1.4220 1.4340 1.4462 1.4574 1.4695 1.4796 1.4920 1 1.5047 1 1.5297 1.5512 1.5696 3.80 1,4130 1.4195 1.4253 1.4317 1.4386 1.4455 1.4517 1.4596 1.4730 1 1.4864 1.5122 1 1.5345 1-1.3544 3.90 L4422 1.4487 1.4545 1.4597 1.4658 1.4717 1.4773 1.4923 1.4863 1.4895 1.5093 1.5333 1.5551 4.00 1,4808 1.4881 1.4941 1.4999 1.5058 1.5123 1.5186 1.5243 1.52S8 1.5325 1.5391 1.5475 1.5706 4.10 1.4799 1.4885 1.4954 1.5013 1,5076 1.5143 1.5210 1.5271 1.5321 1.5362 1.3427 1.5481 1.5526 4.20 1.4725 1.4802 1.4861 1.4917 1.4976 1.5036 1.5091 1.5138 1.5170 1.5194 1.5229 1.5261 1.5301 4.30 1,4767 1.4859 1.4928 1.4990 1.5050 1.5111 1.5169 1.5219 1.5256 1.5284 1.5327 1.5367 1.5414 4.40 1.4781 1.4880 1.4962 1.5029 1.5093 1.5157 1.3217 1.5268 1.5308 1.5340 1.5392 1.5439 4.50 1.4773 1.4897 1.4997 1.5062 1.5134 1,5203 1.5266 1.5321 1.5365 1.5401 1,5459 1.5511

Calc Number: GEO.HBIP.03 0 7 Rev Number: 0 Sheet Number: 128 of 349 Date: 08/27/03 4.60 I 1.4779 1.4902 1.5009 1.5093 1.5173 1.5250 1.5320 1 1.5381 J 1.5429 1.5470 1.5536 1 1.5595 1.5656 4.70 1.4778 1.4909 1.5032 1.5126 1.5214 1.5299 I.5378 1.5445 1.5504 1.55521 1.5630 j 1.5696 1.5759 4.80 1.4889 1.5021 1.5130 1.5224 1.5308 1.5384 1.5447 1.5502 1.5543 1.55?76 1.5626 1.5656 1.56.66 4.90 1.4947 1.5081 1.5196 1.5296 1.53S6 1.5470 1.5544 1.5607 1.5658 1.5700 1.5768 1.5814 1.5X39 5.00 1.4892 1.5030 1.5147 1.5251 1.5348 1.5440 1.5524 1.5598 1.5659 1.5710 1.5794 1.5857 1.5X')6 5.10 1.4842 1.4974 1.5100 1.5210 1.5314 1.5415 1.5509 1.5592 1.5662 1.5725 1.5827 1.5903 1.5957 5.20 1.4800 1.4934 1.5059 1.5175 1 1.5286 1.5394 1.5499 1 1.5593 1.5675 1 1.5746 1.5865 1.5956 1 1.6022 r

t---------÷-------

t 5.40 1.4614 I 1.4672 1.4766 1.4885 i 1.5011 1.5 137 1.5261 1.5376

1:-5479 1 1.5569 ---r.5763r--1.5924 1 1.60FSP-5.60 1.4194 1.4275 1.4313 1.4338 1.4429 1.4561 1.4707 1.4855 1.4993 1.5120 1.5339 1.5513 1.5652 5.80 1.3774 1.3824 1.3861 1.3886 1.3914 1.3952 1.4086 1.4240 1.4386 1.4522 1.4753 1.4937 1.5082 6.00 1.3582 1.3632 1.3690 1.3763 1.3834 1.3930 1.4031 1.4125 1.4208 1.4278 1.4386 1.4574 1.4732 6.20 1.3519 1.3618 1.3686 1.3732 1.3780 1.3816 1.3878 1.3959 1.4026 1.4079 1.4151 1.4183 1.41XX 6.40 1.3814 13886 1.3938 1.3980 1.4018 1.4056 1.4093 1.4131 1.4166 1.4201 1.4279 1.4352 1.4412 6.60 1.3617 1.3694 1.3743 1.37S5 1.3820 1.3862 1.3902 1.3946 1.3992 1.4036 1.4131 1.4221 1.4293 6.80 1.3624 1.3679 1.3716 1.3743 1.3748 1.3755 1.3776 1.3829 1.3883 1.3933 1.4042 1.4142 1.4225 7.00 1.3881 1.3938 1.3942 1.3934 1.3929 1.3919 1.3906 1.388s8 1.3870 1.3849 1.3928 1.4024 1.4098 7.20 1.4064 1.4104 1.4122 1.4135 1.4135 1.4134 1.4126 1.4115 1.4104 1.4090 1.4122 1.4220 1.4297 7.40 1.4269 1.4346 1.4361 1.4373 1.4379 1.4387 1.4388 1.4381 1.4371 1.4396 1.4515 1.4618 1.4699 7.60 1.4049.. 1.4143 1.4195 1.4208 1.4221 1.4236 1.4291 1.4373 1.4447 1.4515 1.4633 1.4740 1.4813 7.80 1.4042 1.4117 1.4167 1.4206 1.4234

'i,423S7 1.4272 1.4283 1.4285 1.4351

'-T.44"66 -1.4564 1.4644 8.00 1.3890 1.4003 1.4066 1.4120 1.4153 1.4184 1.4213 1.4232 1.4249 1.4260 1.4341 1.4436 1.4513 8.50 1.4125 1.4258 1.4358 1.4424 1.4463 1.4499 1.4515 1.4530 1.4538 1.4536 1.4527 1.4503 1.4575 9.00 1.4230 1.4384 1.4503 1.4579 1.4642 1.4670 1.4688 1.4690 1.4688 1.4684 1.4666 1.4636 1.4606 9.50 1.4129 1.4284 1.4413 1.4498 1.4549 1.4597 1.4605 1.4599 1.4587 1.4643 1.4703 1.474S 10.00 1.4256 1.4377 1.4449 1.4485 1.4536 1.4571 1.4605 1.4637 1.4669

.470 1.4786 1.4R58 1.4907

Caic Number: GEORf-BIP.03.02 Rev Number: 0 Sheet Number: 129 of 349 Date: 08/27/03 Table 9-Av~era antllification factor for the up er soUl profile, NM7.0.

Per

____J____

083 82 (sec) 0.1 I R 02 0.3 g 0.49 0.SR 06 0.7ie O.8g 0.97 1.0Z L~

1. 4 e

.6&

0.01 1.8493 1.7348 1.5964 1.4577 1.3326 1.2301 1.1627 1.1108 1.0641 1.0176 0.9388

____7_0 0.8123_

0.03 1.9270 1.8028 1.6571 1.506 1.3734 1.2660 1.1953 1.1413 1.0929 1.0446 0.9626 0.89284 0.8304 0.04 1.7552 1.6368 1.4925 1.351 1.2291 1.1302 1.0632 1.0143 0.9704 0.9271 0.85332 0.7895 0.73318 0.05 1.7008 1.5342.,

1.3954 1.2658 1.1477 I1.0527 0.9852 0.9361 0.8951 0.8536 0.7831 0.7225 0.6710 0.06 1.7484 1.49417 1.3253 11.1994 1 0704 10.9645 0.9061 0.8623 0.8225.

)

04

.7-s6" -1766 0:6089 0.07 1.7484 1.4557 1.2679 1.1306 1.0208 0.9357 0.8584 0.8072 0.7649 0.7298 0.6698

. 0.6206 0.5735 0.08 1.8218 1.4633 1.3197 1.1862 1.0516 0.9602 0.8782 0.8105 0.7634 0.7200 0.6499 0.5895 0.5377 0.09 1.9353 1.4535 1.29-29 1.1713 1.0468 0.9585 0.8800 0.81 12 0.7566 0.7123 0.6421 0.58408 0.5255 0.10 2.1173 1.6355 1.3471 1.1873 1.0883 0.9881 0.8996 0.8216 0.7541 0.7007 0.6202 0.5604 0.5065 0.11 2.1982 1.7671 1.4764 1.2965 1.1593 1.0377 0.9400 0.8655 0.8081 0.7570 0.6661

0. 593 4 0.5297 0.12 2.1207 1.9185 1.6482 1.4301 1.2747 1.1581 1.0473 0.9473 0.8598 0.7802 10.6641 0.5963 0.5331 0.13 2.1293 1.8694 1.6866 1.5103 1.3529 1.2140 1.1061 1.0062 0.9151 0.8295 10.6925 0.5852 0.5221 0.14 2.1853 1.9946 1I.7703 1.5727 1.4162 1.2935 1.1863 1.0866
0. 99F13 0.9015 10.7407 0.6110 0.5254 0.15 2.0388 1.8216 1.7056 1.5340 1.4039 1.2866 1.1780 1.0755 0.9818 0.8962 0.7508 0.6370 0.5507 0.16 2.3145 1.9064 1.6746 1.5406 1.4179 1.3025 1.1906 1.0903 0.9956 0.9067 0.7591 0.6557 0.5771

.Qd7 2.6295 2.1466, 1.7496 1.5516 1.3913 1.2687

....L1722--

1.0904 11.0108 0.9541 0.8418 0.7308 0.6331 0.18 2.6397 2.3909 t9698 1.34 145

.2507 1.88 111

.0'761 1.15W.90

?769 0.6835 0.19 2.6166 2.4089 2.0930 1.8314 1.59-70 1.4059

- 1.2549 1.1229 1.0231 0.9625 0.8632 0.7584 0.6614 0.20 2.6089 2.4705 2.2315 1.9680 1.7304 11.5273 1.3692 1.2251 1.1014 1.0080 0.8377 0.7505 0.6497 0.21 2.5706 2.4485 12.2330 2.0916 1.9307 1.7529 1.5807 1.4276 1.2973 1.1825 11.0052 0.86S3 0.7456 0.22 2.5639 2.3988 2.1996 2.0764 1.9531 1.8048 1.6478 1.4948 1.3630 1.2454 1.0531 0.8954 0.7713 0.23 2.5679 2.4723 2.2951 2.1264 1.9945 1.8715 1.7389 1.6151 1.4952 1.3784 1.1I808 11.0090 0.8629 0.24 2.2961 2.3546 2.2624 2.1089 2.0153 1.910D 1.7971 1.68'20 1.5697 1.4568 1.2470 11.0645 0.9119 0.25 2.0974 2.1782 2.1748 2.1116 2.0495 1.9619 1.8563 1.7446 1.6362 1.5258 1.3145 1.1374 10.9722 0.26 1.9716 1.9801 2.0415 2.0620 2.0394 1.9757 1.8840 1.7790 1.6742 1.5864 1.4087 1.2425 1.0835 0.27 1.7706 1.7579 1.7968 1.8439 1.8527 1.8222 1.7661 1.7023 1.6383 1.5700 1.4372 1.2855 1.1282 0.28 1.8051 1.6841 1.6314 1.6238 1.6573 1.6762 1.6671 1.6370 1.5938 1.5424 11.4381 1.3213 1.1954 0.29 1.8332 1.7025 1.6472 1.5778 1.5518 1.5761 1.5782 1.5556 i1.5196 1.4'713 1.3903 1.2891 1.1718 0.30 1.8368 1.6966 1.6394 1.5731 1.5220 1.4872 1.4531 1.4395 1.4312 1.4168 1.3474 1.2502 1.1339 0.31 1.8858 1.7291 1.6343 1.5551 1.4,788 1.4384 1.4016 1.3797 1.3832 1.3756 1.3341 11.2768 1.1880 0.32 1.9357 1.7395 1.6609 1.5616 1.4872 1.4278 1.3752 1.3444 1.3276 1.3242 1.3352 1.3199 11.2608 0.33 2.0684 1.8397 1.6879 1.5867 1.5077 1.4493 1.3988 1.3577 1.3271 1.3181 1.3562 1.3716 1.3305 0.34 2.1132 1.8686 1.6998 1.5482 1.4410 1.3826 1.3318 1.2904 1.2580 1.2276 1.2105 1.2340

-1.2069 0.35 2.1424 1.9212 1.7727 1.6045 1.4552 11.3599 1.3035 1.2631 11.2326 1.2056 11.1651 1.1576 1.1423 0.36 2.1641 1.9820 1.8455 1.6904 1.5678 1.4667 1.3791 1.3082 11.2501 1.1960 1.1395 1.1203 1.1070 0.37 2.1238 1.9768 1.8629 1.7355 1.6160 11.5190 1.4359 1.3673 1.3117 1.2597 1.1778 1.1151 1.0653 0.38 2.1669 1.9668 1.8430 1.7154 1.5972 11.5000 1.4207 1.3592 1.3071 1.2581 1.1882 1.1309 1.0688 0.39 2.1580 2.0153 1.8578 1.7264 1.6186 1.5403 1.4693 1.4080 1.3561 1.3050 1.2194 1.1494 1.0830 0.40 2.1392 2.0435 11.9218 1.7670 1.6523 1.5738 1.5050 1.4458 1.3949 1.3452 1.2596 1.1789 1.0932 0.41 2.0802 2.0735 11.9918 1.8473 1.6950 1.5896 1.5020 1.4439 1.3949 1.3461 1.2621 1.1807 1.0939 0.42 2.0651 2.0738 2.0234 1.8851 1.7290 1.6222 1.5460 1.4822 1.4248 1.3664 11.2593 1.1741 1.0902 0.43 1.9904 2.0258 1.9930 1.8720 1.7546 1.6631 1.5926 1.5270 11.4690 1.4105 1.3036 1.1947 1.0916 0.44 1.8333 1.8871 1.8999 1.8459 1:7765 1.6834 1.5939 1.5239.

1.4676 1.4114 1.3088 1.2066 1.1075 0.45 1.8088 1.8584 1.9262 1.9186 1.8360 11.7281 1.6340 1.5656 1.5038 1.4414 1.3437 1.2508 1.1508 0.46 1.7786 1.8303 1.8947 1.8875 1.8066 11.7284 1.6605 1.5936 1.5312 1.4687 1.3615 1.2711 11.1766 0.47 1.7295 1.7517 1.7883 1.7880 1.7492 1.6970 1.6291 1.5655 1.5024 1.4520 1.3702 1.2853 1.1976 0.48 1.7316 1.7464 11.7503 1.7314 1.7049 1.6647 1.6282 1.5821 1.5326 1.4780 1.3750 1.3009 1.2140 0.49 1.7228

-1.7376 11.7416 1.7204 1.6954 1.6755 1.6413 1.5972 1.5504 1.4999 1.3995 1.3101 1.2239 0.50 1.7181 1.7339 1.7395 1.7206 1.6940 1.6718 1.6386 1.5986 1.5557 1.5067 1.4083 1.3224 1.2362 0.51 1.7114 1.7283 1.7360 1.7198 1.6813 1.6485 1.6171 1.5787 1.5374 1.4910 1.4046 1.3309 1.2447 0.52 1.7066 1.7249 1.7337 1.7199 1.6834 1.6431 1.6009 1.5607 1.5224 1.4830 1.4113 11.3378 11.2520 0.53 1.7031 1.7221 1.7318 1.7196 1.6851 1.6457 1.6044 1.5646 1.5269 1.4878 1.4167 1.3440 11.2597 0.54 1.7010 1.7200 1.7305 1.7191 1.6858 1.6475 1.6070 1.5679 1.5307 1.4921' 1.4224 1.3513 1.2685 0.55 1.6994 1.7180 11.7288 1.7179 1.6857 1.6483 1.6089 1.5708 1.5345 1.4968 1.4432 1.3783 1.2859 0.56 1.6981 1.7155 11.7264 1.7162 1.6853 1.6492 1.6110 1.5742 1.5389 1.5101 1.4641 1.3980 1.3054 0.57 1.6962 1.7127 1.7238 1.7147 1.6852 1.6507 1.6142 1.5787 1.5449 1.5180 1.4731 1.4087 1.3309 0.58 1.6939 1.7098 1.7213 1.7136 1.6856 1.6530 1.6184 1.5845 1.5520 1.5200 1.4865 1.4463 1.3684 0.60 1.6690 1.6829 1.6961 1.6908 1.6670 1.6381 1.6069 1.5787 1.5582 1.5373 1.5011 1.4597 1.3934 0.62 1.6812 1.6664 1.6635 1.6612 1.6404 1.6151 1.5873 1.5593 1.5315 1.5110 1.4896 1.4626 1.4010 0.64 1.6801 1.6740 1.6729 1.6580 1.6270 11.5931 1.5625 1.5360 1.5128 11.4911 1.4729 1.4550 1.4143 0.66 1.6899 1.6819 1.6825 1.6715 1.6432 1.6115 1.5813 1.5543 1.5301 1.5070 1.41311.51 1.4128 0.68 1.703 1.95 1.6925 1.6828 1.6566 1.6263 1.5963 1.5692 1.5448 1.5213 1.48

.8 7

1.04

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 130 of 349 Date: 08/27/03 0.70 1 1.7170 1 1.6993 1 1.6982 1 1.6889 1 16639 1 1.6349 1.6059 1 1.5792 1 1.5546 1 1.5311 1.4929 1 1.4568 1.4127 I i-.-.--

-.4-.-.

4 4 ________

.

4-..--.------

4 0.72 1 1.7471 1 1.7155 1 16977 1.6887 I 16650 1 1.6379 1.6106 1 1.5848 1.5609 1 1.5376 1.4998 1 1.4639 1.4213 0.74 1.7404 1.7167 1.7013 1.6845 1.6627 1.6377 1.6122 1.5879 1.5648 1.5423 1.5054 j 1.4709 1.4309 0.76 1.8016 1.7501 1.7217 1.69R6 1.6642 1.6366 1.6131 1.5903 1.5682 1.5464 1.5106 1.4779 1.4407 0.78 1.8593 1.7663 1.7369 1.7153 1.6825 1.6492 1.6188 1.5920 1.5671 1.5428 1.5025 1.4712 1.4373 0.80 1.9751 1.8791 1.804 1.7456 1.7021 1.6579 1.6227 1.5962 1.5714 1.5472 1.5063 1.4680 1.4267 0.82 2.1537 2.0567 1.9719 1.8993 1.8237 1.7604 1.7179 1 6795 1.6433 1.6076 1.5432 1.483S 1.4373

-0.84 2.1928 2.1017 2.0238 1.9426 1.67S 1.8002 1.7i32 t-6990 1.6692 371

'.5741 1.5609X-f-4601 0.86 2.2463 2.1809 2.1213 2.0551 1.9827 1.9221 1.8675 1.8154 1.7655 1.7165 1.6504 1.5859 1.5200 0.88 2.4001 2.3325 2.2733 2.2079 2.1359 2.0689 2.0094 1.9582 1.9091 I1.627 1.7731 1.6922 1.6252 0.90 2.3901 2.3257 2.2695 2.2072 2.1390 2.0754 2.0189 1.9688 1.9231 1.8787 1.7919 1.7077 1.6308 0.92 2.3827 2.3316 2.2808 2.2188 2.1471 2.0S72 2.0337 1.9861 1.9424 1.8997 1.8157 1.7325 1.6544 0.94 2.4085 2.3646 2.3210 2.2658 2.1979 2.1286 J 2.0638 2.0055-1.9636 1.9226 1.8413 1.7594 1.6806 0.96 2.4395 2.3985 2.3601 2.3105 2.2474 2.1818 2.1198 2.0627 2.0101 1.9589 1.8698 1.7890 1.7097 0.98 2.4676 2.4280 2.3937 2.3490 2.2903 2.2284 2.1687 2.1130 2.0609 2.0098 1.9102 1.813 1.7386 1.00 2.4737 2.4367 2.4059 2.3659 2.3116 2.2533 2.1964 2.1426 2.0916 2.0412 1.9420 1.8429 1.7552 1.05 2.6525 2.6271 2.5772 2.4983 2.3944 2.3040 2.2525 2.2043 2.1573 2.1096 2.0135 1.9141

-I1.131 1.10 2.6655 2.6705 2.6423 2.5907 2.5046 2.4157 2.3593 2.3155 2.2689 2.2187 2.1135 2.0002 1.8933 1.15 2.4674 2.5204 - 2.S641-2.5933 2.5983.

1.57S4 2.5425 2.4947 2.4383 2.3721 2.2407 2.1057.

A I91 1.20 2.5069 2.6168 2.6865 2.7266 2.7340 2.7138 2.6767 2.6291 2.5813 2.5258 2.4342 21 9- -- IgSX' 1.25 2.3749 2.4893 2.5723 2.6271 2.6515 2.6599 2.6529 2.6413 2.6218 2.5939 2.5184 2.4191 2.3025 1.30 2.2743 2.3748 2.4667 2.5381 2.5889 2.6192 2.6354 2.6393 2.6324 2.6167 2.5628 2.4822 2.3803 1.35 2.2083 2.3060 2.4046 2.4905 2.5601 2.6085 2.639S 2.6559 2.6586 2.6509 2.6096 2.5402 2.4493 1.40 2.1230 2.2343 2.3325 2.4171 2.4881 2.5395 2.5746 2.5950 2.6026 2.6001 2.5711 2.5166 2.4418 1.45 1.9873 2.0920 2.1771 2.2545 23213 2.3745 2.4141 2.4408 2.4559 2.4617 2.4504 2.4128 2.3537 1.50 1.8625 1.9732 2.0627 2.1422

-2.2112 2.2646 2.3041 2.3307 2.3484 2.3585 2.3648 2.3523 2.3230 1.55 1.S575 1.9605 2.0476 2.1304 2.2027 2.2609 2.3061 2.3393 2.3632 2.3801 2.3956 2.3940 2.3944 1.60 1.S886 1.9746 2.0461 2.1109 2.1835 2.2520 2.3097 2.3569 2.3962 2.4312 2.4815 2.5077 2.5157 1.65 1.S751 1.9657 2.0415 2.1126 2.1783 2.2352 2.2850 2.3275 2.3645 2.3986 2.4499 2.5183 2.5603 1.70 1.7759 1.8681 1.9415 2.0058 2.0622 2.1094 2.1498 2.1834 2.2161 2.2554 2.3373 2.4229 2.4876 1.75 1.7053 1.7978 1.8729 1.9392 1.9967 2.0446 2.0853 2.1193 2.1475 2.1719 2.2102 2.2517 2.3096 1.80 1.6495 1.7357 1.8123 1.8830 1.9465 2.0011 2.0484 2.0881 2.1210 2.1497 2.1953 2.2333 2.2810 1.85 1.6426 1.7270 1.8046 1.8770 1.9428 1.9999 2.0496 2.0913 2.1262 2.1569 2.2064 2.2449 2.2946 1.90 1.6632 1.7175 1.7926 1.8669 1.9353 1.9945 2.0459 2.0893 2.1259 2.1584 2.2115 2.2540 2.3067 1.95 1.6662 1.7156 1.7660 1.8394 1.9084 1.9684 2.0206 2.0649 2.1026 2.1366 2.1928 2.2390 2.2S22 2.00 1.6578 1.7089 1.7518 1.S026 1.8718 1.9324 1.9853 2.0307 2.0696 2.1054 2.1654 2.2166 2.2660 2.05 1.6529 1.7050 1.7459 1.7890 1.8296 1.887 1.9431 1.9903 2.0314 2.0703 2.1366 2.1932 2.2473 2.10 1.6199 1.6731 1.7146 1.7573 1.7978 1.8344 1.8755 1.9215 1.9620 1.9999 2.0692 2.1290 2.1858 2.15 1.6046 1.6430 1.6799 1.7230 1.7642 1.8012 1.8346 1.8687 1.9112 1.9508 2.0157 2.0697 2.1196 2.20 1.5867 1.6263 1.6574 1.6853 1.7273 1.7649 1.7990 1.8284 1.8562 1.8970 1.9643 2.0208 2.0732 2.25 1.5635 1.6041 1.6373 1.6654 1.6887 1.7227 1.7574 1.7876 1.8133 1.8366 1.9051 1.9638 2.0189 2.30 1.5398 1.5812 1.6166 1.6464 1.6714 1.6917 1.7146 1.7455 1.7720 1.7960 1.8435 1.9046 1.9628 2.35 1.5181 1.5605 1.5974 1.6285 1.6550 1.6768 1.6949 1.7099 1.7315 1.7562 1.7998 1.8459 1.9079 2.40 1.5006 1.5437 1.5813 1.6132 1.6408 1.6639 1.6834 1.6996 1.7133 1.7261 1.7634 1.8046 1.8654 2.50 1.4780 1.5240 1.5616 1.5933 1.6209 1.6450 1.6667 1.6850 1.7006 1.7153 1.7416 1.7714 1.8297 2.60 1.4695 1.5126 1.5480 1.5787 1.6050 1.6268 1.6451 1.6653 1.6828 1.6992 1.7288 1.7560 1.7963 2.70 1.3858 1.4288 1.4662 1.4994 1.5300 1.5569 1.5809 1.6019 1.6202 1.6376 1.6684 1.6965 1.7250 2.80 1.3613 1.4033 1.4395 1.4717 1.4985 1.5202 1.5385 1.5545 1.5684 1.5815 1.6037 1.6230 1.6411 2.90 1.3571 13947 1.4288 1.4629 1.4923 1.5169 1.5380 1.5561 1.5717 1.5863 1.6112 1.6334 1.6553 3.00 1.3903 1.4306 1.4648 1.4949 1.5213 1.5433 1.5618 1.5772 1.5898 1.6008 1.6159 1.6295 1.6543 3.10 1.4019 1.4446 1.4814 1.5146 1.5450 1.5704 1.5921 1.6104 1.6258 1.6395 1.6598 1.6743 1.6846 3.20 1.3425 1.3865 1.4254 1.4608 1.4934 1.5209 1.5449 1.5656 1.5833 1.5992 1.6239 1.6428 1.6578 3.30 1.3103 1.3543 13947 1.4319 1.4666 1.4967 1.5233 1.5466 1.5666 1.5848 1.6139 1.6374 1.6569 3.40 1.2541 1.2841 1.3206 1.3564 1.3903 1.4211 1.4499 1.4749 1.4966 1.5166 1.5501 1.5794 1.6068 3.50 1.2582 1.2765 1.2893 1.3070 1.3422 1.3745 1.4034 1.4288 1.4509 1.4714 1.5056 1.5349 1.5611 3.60 1.2440 1.2695 1.2916 1.3129 1.3320 1.3582 1.3841 1.4069 1.4271 1.4459 1.4778 1.5057 1.5318 3.70 1.2303 1.2441.

1.2555 1.2761 1.2958 1.3200 1.3449 1.3681 1.3897 1.4100 1.4450 1.4762 1.5059 3.80 1.2406 1.2576 1.2688 1.2812 1.2928 1.3054 1.3317 1.3549 1.3750 1.3935 1.4235 1.4501

"'1.4762 3.90 1.2537 1.2734 1.2875 1.3021 1.3162 1.3291 1.3415-1.3544 1.3761 1.3963 1.4300 1.4600 1.4883 4.00 1.2629 1.2772 1.2936 1.3108 1.3274 1.3426 1.3571 1.3705 1.3827 1.3944 1.4321 1.4656 1.4960 4.10 1.2544 1.2705 1.2812 1.2939 1.3075 1.3267 1.3442 1.3600 1.3739 1.3873 1.4113 1.4462 1.4780 4.20 1.2211 1.2391 1.2511 1.2653 1.2782 1.2896 1.3019 1.3187 1.3338 1.3480 1.3738 1.3994 1.4320 4.30 1.1931 1.2122 1.2259 1.2411 1.2550 1.2675 1.2797 1.2918 1.3033 1.3148 1.3364 1.3597 1.3904 4.40 1.1885 1.2078 1.2240 1.2413 1.2559 1.2681 1.2794 1.2897 1.2987 1.3066 1.3259 1.3467 1.3728 4.50

-1.1974 1.2180 1.2352 1.2536 1.2690 1.2817 1.2932 1.3037 1.3129 1.3209 1.3356 1.3491 1.3706

Calc Number: GEO.HlBIP.03.02 Rev Number: 0 Sheet Number: 13 1 of 349 Date: 08/27/03 r - r n 4.60 l 1.2046 l 1.2267 1 1.2451 l 1.2647 l 1.2809 l 1.2940 l 1.3058 1 1.3164 7 1.3257 l 1.3338 7 1.3486 1.3642 1 1.37S2 4.70 1 1.2063 1 1.2283 1 1.2472 1 1.2676 1 1.2S60 1 1.3021 1 1.3173 1 1.3317 7 1.3451 I 1.3577 1 1.3795 1 1.39,2U 1.4139 I 4.80.

1.1829 1.2059 1.2255 1.2467 1.2655 1.2820 1.2976 1.3122 1.3259 1.3389 1.3617 1.3818 1.3993 4.90 1.1463 1.1709 1.1909 1.2123 1.2315 1.2483 1.2640 1.2788 1.2927 1.3062 1.3301 1.3516 1.3711 5.00 1.1142 1.1412 1.1619 1.1836 1.2030 1.2199 1.2356 1.2503 1.2644 1.2784 1.3034 1.3266 1.3483 5.10 1.0965 1.1135 1.1366 1.1594 1.1793 1.1963 1.2118 1.2264 1.2404 1.2543 1.2804 1.3052 1.3292 5.20 1.1001 1.1028 1.1259 1.1490 1.1671 1.1513 1.1970 1.2116 1.2254 1.2393 1.2659 1.2924 1.3189

-5.40 1.1740

1.1787 - 1.1823 1:2043 1:2236

-T:23 79 -1.2495 1.2597'

-1.2731 1.2860 1:309' 1.3336 1.35842 5.60 1.1920 1.1986 1.2037 1.2044 1.2246 1.2394 1.2512 1.2614 1.2702 1.2779 1.2923 1.3067 1.3248 5.80 1.2270 1.2357 1.2445 1.2580 1.2676 1.2730 1.2764 1.2844 1.2934 1.3015 1.3165 1.3317 1.3479 6.00 1.1642 1.1791 1.1920 1.2025 1.2097 1.2132 1.2163 1.2186 1.2204 1.2218 1.2244 1.2395 1.2555 6.20 1.1720 1.1792 1.1827 1.1868

-1.188S 1.I870 1.1832 1.1807 1.1804 1.1795 1.1788 1.159 1.1931 6.40 1.1675 1.1771 1.1829 1.1871 1.1889 1.1877 1.1I48 1.1813 1.1772 1.1732 1.1675 1.1652 1.16X9 6.60 1.1579 1.1683 1.1783 1.1869 1.1922 1.1931 1.1923 1.1900 1.1870 1.1831 1.1783 1.1851 1.1929 6.80 1.1541 1.1678 1.1781 1.1876 1.1944 1.1975 1.1987 1.1987 1.1982 1.1974 1.2015 1.2070 1.2112 7.00 1.1707 1.1826 1.1931 1.2006 1.2077 1.2122 1.2148 1.2161 1.2173 1.2224 1.2312 1.2384 1.2442 7.20 1.1998 1.2121 1.2234 1.2320 1.2368 1.2378 1.2366 1.2374 1.2391 1.2441 1.2547 1.2638 1.2713 7.40 1.2197 1.2337 1.2465 1.2556 1.2612 1.2626 1.2663 1.2697 1.2716 1.2727 1.2730 1.2765 1.2854 7.60 1 1.2483 I 1.2664 I 1.2795 1.2901 1.2962 I 1.3026 I 1.3084 I 1.311S I 1.3140 i 1.3151 1 1.3159 1 1.3149 1 1.3130

,>-sH

- -; S;.,

7.801 1.2550r

'.2709 I 1.2a57-T 2'80 1.3061 1.310-6 I l.315` 1`.3181i203-1.3215 1.3212

' 1.3212 1 ll3-19C 8.00 1.2476 1.2603 1.2731, 1.2827 1.2888 1.2933 1.2953 1.2956 1.2948 1.2941 1.2946 1.2938 1.2928 8.50 1.1861 1.2001 1.2146 1.2261 1.2332 1.2365 1.2374 1.2366 1.2351

' 1.2337 1.2304 1.2272 1.2268 9.00 1.1976 1.2092 1.2214 1.2296 1.2332 1.2332 1.2307 1.2272 1.2230 1.2191 1.2108 1.2031 1.2047 9.50 1.2684 1.2809 1.2946 1.3039 1.3090 1.3096 1.3084 1.3060 1.3027 1.2995 1.2925 1.2860 1.2806 10.00 1.2823 1.2968 1.3085 1.3192 1.3249 1.3263 1.3259 1.3243 1.3220 1.3194 1.3136 1.3081 1.3037

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 132 of 349 Date: 08/27/03 T21,lp 9-12.

Avernec am-Kfitinfac-r Cair the tsher soil nrnfile. M=7.S Per1 (sec)

Olg 0.2g 0.3g 0.4g 0.5g 0.6g 0.7g 0.8g 0.9g L.Og 1.2g 1.4g 1.6y 0.01 1.7490 1.4413 1.3777 1.3489 1.2820 1.2101 1.1409 1.0772 1.0275 0.9791 0.R882 0.8458 0.8129 0.03 1.8159 1.4927 1.4136 1.3819 1.3114 1.2359 1.1634 1.09S4 1.0452 0.9951 0.9007 0.8560 0.8225 0.04 1.5642 1.2970 1.1828 1.1512 1.0876 1.0218 0.9592 0.9054 0.85X2 0.8163 0.7376 0.6995 0.6720 0.05 1.6229 1.2929 1.0422 1.0034 0.9507 O.S939 0.8383 0.7909 0.7462 0.7093 0.6406 0.6052 0.5812 0.06 1.?134 12965

-1.0585 05139 0.8786 0.8236.0.'7748 0.7342 0.6882t ';0:6507 0.5S76 -- e:5-54x 0.5314 0.07 1.6674 1.3527 1.0882 0.9458 0.8737 0.8063 0.7552 0.7079 0.6562 0.6091 0.5431 0.5083 0.4871 0.08 1.7231 1.3979 1.1558 0.9690 0.8701 0.7947 0.7378 0.6852 0.6365 0.5930 0.5154 0.4810 0.4584 0.09 1.9200 1.5227 1.2659 1.0647 0.9391 0.8406 0.7592 0.6893 0.6388 0.5939 0.5213 0.4713 0.4483 0.10 2.0112 1.5369 1.2742 1.1370 1.0132 0.9037 0.8094 0.7366 0.6772 0.6264 0.5409 0.4826 0.4443 0.11 2.1297 1.6047 1.2807 1.1248 0.9913 0.8947 0.8188 1 0.7555 0.6962 0.6428 0.5497 0.4818 0.4283 0.12 1.9041 1.6258 1.3971 1.2062 1.0513 0.9484 0.8688 0.7972 0.7339 0.6745 0.5700 0.4954 0.4357 0.13 2.0828 1.6503 1.4076 1.2593 1.1072 0.9926 0.9035 0.8180 0.7360 0.6580 0.5423 0.4831 0.4375 0.14 2.0712 1.7842 1.4898 1.2850 1.1374 1.0187 0.9202 0.8314 0.7470 0.6765 0.5509 0.4761 0.4324 0.15 1.9452 1.7402 1.4950 1.3260 1.1897 1.0577 0.9714 0.9015 0.8223 0.7438 0.5972 0.4973 0.4348 0.16 2.1148 1.S229 1.5847 1.3880 1.2392 1.1238 1.0349 0.9592 0.8738 0.7912 0.6503 0.5445 0.4677

~~~~~~,

.~~~~~~~~~~~~~~~~~1n~~~~~047 0.17 23610 I I RAS5 I I752 1 19117 i Ivnn I I(lQ3 1.1061 I.00 16 A 9009 n 8091 0.6589 1 0.5537 0.4874 l

A

'I18 I 2575 1 i.U75 1 7790 1.17mt

'-f-Ifly'n 1 1751

-1 07m, 0 9941 n 0.9,

, A R09 0:6X37 t 0:5R97 1 0:5106 1 --

0.19 2.4552 2.1617 1.8769 1.6301 1.42S2 1.2561 1.1201 1.0159 0.9271 0.8639 0.7527 0.6489 0.557t 0.20 2.4255 2.2183 1.9610 1.7512 1.5185 1.3298 1.1715 1.0581 0.9854 0.9243 0.8117 0.7052 0.6021 0.21 2.3183 2.1551 2.0670 1.9088 1.6671 1.4340 1.2667 1.1373 1.0404 0.9630 0.8347 0.7311 0.6336 0.22 23594 2.1682 2.0525 1.9245 1.7412 15425 1.3560 1.2121 1.1094 1.0248 0.8796 0.7668 0.6676 0.23 2.3459 2.2045 2.0886 1.9396 1.7653 1.5998 1.4398 1.2885 1.1473 1.0453 0.9051 0.7928 0.6962 0.24 2.2808 2.3162 2.1799 1.9812 1.8088 1.6692 1.5341 1.3817 1.2336 1.1212 0.9420 0.8251 0.7252 0.25 2.0977 2.1523 2.0977 1.9832 1.8632 1.7677 1.6536 1.5149 1.3711 1.2259 1.0080 o.mo 0.7605 0.26 1.9251 1.9143 1.9589 1.9526 1.8866 1.7901 1.6803 1.5575 1.4243 1.2878 1.0568 0.8855 0.7715 0.27 1.8672 1.8297 1.8850 1.8959 1.8423 1.7577 1.6790 1.5719 1.4552 1.3263 1.0769 0.9105 0.7794 0.28 1.7996 1.7143 1.6983 1.7311 1.7507 1.7278 1.6860 1.5952 1.4941 1,3811 1.1439 0.9787 0.8422 0.29 1.7339 1.6v83 1.6660 1.6659 1.6575 1.6442 1.5915 1.5024 1.4254 1.3458 1.1719 1.0262 0.8850 0.30 1.7340 1.6700 1.6416 1.6374 1.6314 1.6041 1.5493 1.4948 1.4208 1.3335 1.1647 1.0413 0.9241 0.31 1.7304 1.6513 1.5676 1.5195 1.5116 1.4886 1.4386 1.3727 1.3062 1.2591 1.1499 1.0432 0.9236 0.32 1.7571 1.6745 1.6048 1.5472 1.4967 1.4458 1.4063 1.3497 1.2913 1.2452 1.1437 1.0413 0.9335 0.33 1.7521 1.6559 1.5934 1.5467 1.4986 1.4484 1.3973 1.3423 1.2858 1.2244 1.0990 1.0046 0.9028 0.34 1.S488 1.6805 1.6134 1.5468 1.4883 1.4394 1.3848 1.3163 1.2542 1.1952 1.0886 1.0012 0.9272 0.35 1.9234 1.7242 1.6192 1.5354 1.4758 1.4336 1.3834 1.3190 1.2606 1.2051 1.0999 1.0133 0.9264 0.36 1.9380 1.7360 1.6374 1.5402 1.4479 1.3751 1.3311 1.2719 1.2171 1.1651 1.0636 1.0044 0.9356 0.37 2.0369 1.8207 1.6566 1.5384 1.4524 1.3781 1.3132 1.2449 1.1953 1.1537 1.0793 1.0348 0.9849 0.38 2.1975 1.9632 1.7514 1.5814 1.4701 1.4019 13609 1.2993 1.2383 1.1810 1.1029 1.0620 1.0166 0.39 2.3646 2.1164 1.8537 1.6462 1.4959 1.3948 1.3386 1.2875 1.2346 1.1852 1.1087 1.0744 1.0295 0.40 2.2869 2.1325 1.9408 1.7429 1.5537 1.3951 1.2862 1.2059 1.1543 1.1118 1.0428 1.0168 0.9980 0.41 2.2165 2.1717 2.0296 1.8249 1.6224 1.4543 1.3053 1.1849 1.1157 1.0746 1.0158 1.0127 1.0068 0.42 2.2056 2.2072 2.0857 1.S926 1.6947 1.513S 13665 1.2307 1.1188 1.0471 1.0035 1.0022 1.0111 0.43 2.0809 2.1352 2.0618 1.8976 1.7103 1.5332 1.3770 1.2438 1.1337 1.0463 0.9568 0.9573 0.9703 0.44 2.0041 2.1066 2.0574 1.9051 1.7268 1.5518 1.4074 1.2771 1.1676 1.0750 0.9507 0.9387 0.9467 0.45 1.8323 1.9301 1.9275 1.8812 1.7687 1.6198 1.4936 1.3502 1.2210 1.1149 0.950S 0.8830 0.8747 0.46 1-7488 1.8464 1.9070 1.S743 1.7831 1.6860 1.5648 1.4206 1.2921 1.1825 1.006S 0.9189 0.8983 0.47 1.6719 1.7652 1.8499 1.85S7 1.8015 1.698S 1.5741 1.4372 1.3146 1.2097 1.0407 0.9457 0.8995 0.48 1.6060 1.7069 1.7827 1.8022 1.7574 1.6798 1.5766 1.4309 1.3152 1.2162 1.0543 0.9637 0.9087 0.49 1.5471 1.6402 1.7127 1.7338 1.7321 1.6810 1.5794 1.4441 1.3338 1.2321 1.0716 0.9823 0.9276 0.50 1.4887 1.5769 1.6532 1.6890 1.6795 1.6323 1.565S 1.4659 1.3649 1.2684 1.0969 1.0021 0.9482 0.51 1.4497 1.5405 1.6146 1.6421 1.6628 1.6416 1.5809 1.4941 1.4043 1.3133 1.1394 1.0299 0.9631 0.52 1.413S 1.4932 1.5652 1.6005 1.6251 1.6156 1.5695 1.4929 1.4130 1.3305 1.1653 1.0454 0.9668 0.53 1.4195 1.4678 1.5374 1.5812 1.5958 1.5849 1.5469 1.5029 1.4401 1.3664 1.2102 1.0931 1.0053 0.54 1.4364 1.4676 1.5295 1.5587 1.5776 1.5946 1.5930 1.5517 1.4890 1.4135 1.2523 1.1355 1.0495 0.55 1.4584 1.4709 1.5281 1.5627 1.5828 1.5979 1.5944 1.5537 1.4937 1.4242 1.2723 1.1548 1.0621 0.56 1.5010 1.4754 1.5267 1.5595 1.5775 1.5919 1.5881 1.5750 1.5319 1.4678

.1.3160 1.1984 1.1120 0.57 1.5528 1.5326 1.5298 1.5391 1.5421 1.5600 1.5794 1.5688 1.5290 1.4689 1.3352 1.2279 1.1335 0.58 1.6317 1.6196 1.5986 1.5744 1.5677 1.5728 1.5795 1.5630 1.5317 1.5018 1.4087 1.2959 1.1932 0.60 1.6311 1.6476 1.6520 1.6319 1.6132 1.6027 1.5944 1.5895 1.5893 1.5710 1.4765 1.3614 1.2580 0.62 1.5843 1.5439 1.5576 1.5473 1.5413 1.5441 1.5463 1.5388 1.5266 1.5108 1.4519 1.3798 1.2971 0.64 1.5641 1.4940 1.4628 1.4411 1.4311

.4292 1.4486 1.4584 1.4652 1.4702 1.4639 1.4135 1.3425 0.66 1.6422 1.5749 1.5203 1.4642 1.4314 1.4255 1.4278 1.4376 1.4569 1.4721 1.4742 1.4358 1.3808 0.68 -1.7806 1.7085 1.6554 1.5924 1.5405 i.5092 1.5027 1.4912 1.4892 1.4754 1.4765 1.4424 1.3984

Calc Number: GEOI-IBIP.03.02 Rev Number: 0 Sheet Number: 1 33 of 3 49

~ ~~ ~~~~Date:

08/27/03 0.70 1.8138 1.7667 11.7441 1.7084 1.6669 1.6298 1

75993jj.5709 1.5462 1.5183 1.4759 1.4496 1.4198 0.72 1.8003 1.7543 11.7361 1.7072 1.6732 1.6422 1.656j1.59101 1.5673 1.5389 1.4845 1.4541 1.4201 0.74 1.8322 1.7658 11.7434 1.7180 1.6882 1.6605 1.6368 1.6141 1.5916 1.5639 1.5007 1.4447 1.4099 0.76 1.9589 1.8275 1.7507 1.7197 1.6939 1.6698 1.6497

-j1.6307 1.611 1.5860 1.5251 1.4703 1.4225 0.78 2.0638 1.9275 1.8288 1.7317 1.6663 1.6456 1.6289 1.6136 1.5971 1.5738 1.5146 1.4604 1.4127 0.80 2.1151 1.9810 1.8794 1.7744 1.6777 1.6127 1.5-784 1.5667 1.5533 1.5330 1.4779 1.4-268 1.3816 0.82 2.1544 2.0272 1.9380 1.8530 1.7633

.-1.6809 1.6138 11.5634 1.5347 1.5126 11.4664 1.4238 1.3890 0.84 2.21 2.21 2.0503 1.9631 l.9699

'T.7832 1.7075 ~164~

-1.5939

  • r-5461

-1.4S79 1.4047

.136S1 0.86 2.2302 2.1556 12.0893 2.0047 1.9129 1.8267 1.7497 1.6812 1.6220 1.5719 11.4750 1.4013 1.3677 0.88 2.2287 2.1593 12.1019 2.0241 1.9368 1.8534 1.7774 1.7080 1.6475 1.5900 1.4877 1.4062 1.3540 0.90 2.2549 2.1889 2.1295 2.0586 1.9753 1.8937 1.8172 1.7457 1.6824 1.6213 1.5107 1.4240 1.3611 0.92 2.3756 2.2816 2.1871 2.1030 2.0196 11.9367 1.8579 1.7824 1.7145 1.6489 1.5294 1.4361 1.3677 0.94 2.4841 2.4026 2.3111 2.1993 2.0935 1.9993 1.9203 1.8462 1.7784 1.7127 1.5901 1.4933 1.4207 0.96 2.5224 2.4446 2.3599 2.2493 2.1338 2.0389 1.9568 11.8789 1.8076 1.7427 1.6200 1.5231 1.4500 0.98 2.6002 2.5225 2.4286 2.3021 2.1796 2.0796 1.9890 1.9087 1.8380 1.7654 1.6390

1. 5418S 1.4677 1.00 2.6553 2.5780 2.4839

'2.3567 2.2204 2.1167 2.0238 1.9365 1.8532 1.7816 1.6417 1.5433 1.4676 1.05 2.7451 2.6946 2.6396 2.5460 2.4350 2.3242 2.2137 2.1022 1.9983 1.9017 1.7197 1.5856 1.5011 1.10 2.7370 2.7762 2.7745 2.7195 2.6244 2.5293 2.4363 2.3322 12.2187 2.1002 1.8765 1.7127 1.5819 14.-5 2,U&33 2.7777 2.8160..

2.7996 2.7369.-2.6516 2.5552-2.4482 2.3427 2.2395 2.03 12 1.8638 1.7287 1.20 2.5624 2.6487 2.7004 2.7108 2.6799 2.6441 2.5976

-2.5353 '2.4641 2.3F761V' 1785 2.0'263 1:9031j 1.25.-

2.3139 2.4242 2.5039 2.5898 2.6425 2.6557 2.6290 2.5671 2.4814 2.3878 2.1809 2.0524 1.9507 1.30 2.1074 2.2481 2.3708 2.4701 2.5280 2.5470 2.5580 2.5391 2.4981.

2.4411

'2.2820 2.1184 2.0112 1.35 2.0474 2.1742 2.2864 2.38'76 2.4820 2.5609

-2.6226

-2.6506 2.6481 2.6207 2.5109 2.3531

-2.1953 1.40 2.0433 2.1583 2.2648 2.3769 2.4806 2.5654 2.6258 12.6714 2.6968 2.6951 2.6108 2.4714 2.3149 1.45 1.9965 2.0857 2.1806 2.2958 2.4121 2.5138 2.5969 2.6593 2.6957 2.7054 2.6465 2.5333 2.4192 1.50 1.9106 2.0174 2.1165 2.2107 2.2981 2.3902 2.4718 2.5340 2.5734 2.5900 2.5558 2.4834 2.3855 1.55 1.8654 1.9405 2.0221

.2.1029 2.1793 2.2513 2.3152 2.3719 2.4195 2.4536 2.4668 2.4235 2.3647 1.60 1.8933 1.9766 2.0484 2.1112 2.1701 2.2285 2.2849 2.3417.2.3938 2.4416 2.5076 2.5090 2.4689 1.65 1.8989 1.9853 2.0616 2.1296 2.2034 2.2742 2.3424 2.4151 2.4941 2.5607 2.6401 2.6670 2.6492 1.70 1.8396 1.9189 11.9978 2.0737 2.1544 2.2308 12.3037 2.3853 2.4681 2.5393 2.6350 2.6868 2.6807 1.75 A...7622 1.8405 1.9121 1.9773 2.0491 2.1260 2.1998 12.2751 2.3546 2.4287 2.5354 2.5991 267 1.80 1.7066 1.7849 1.8546 1.9217 1.9869 2.0507 2.1322 2.2132 2.2879 2.3543 2.4560 2.5129 2.5481 1.85 1.6886 1.7709 1.8457 1.9159 1.9823 2.0459 2.1064 2.1680 2.2304 2.2902 2.4017 2.4737 2.5183 1.90 1.6683 1.7497 1.8291 1.9062 1.9794 2.0491 2.1155 2.1831 2.2511 2.3162 2.4238 12.4907 2.5329 1.95 1.6263 1.6922 1.7584 1.8364 1.9133 1.9869 2.0572 2.1286 2.1991 2.2661 2.3780 2.4490 2.4944 2.00 1.5357 1.6021 1.6624 1.7257 1.7893 1.8502 1.9107 1.9726 2.0318 2.0932 2.2046 2.2807 2.3355 2.05 1.5028 1.5656 1.6220 1.6809 1.7394 1.7952 1.8486 1.9113 1.9711 2.0269 2.1304 2.2156 2.2881 2.10 1.5357 1.5927 1.6453 1.6995 1.7565 1.8145 1.8697 1.9248 1.9782 2.0299.

2.1207 2.2002 12.2822 2.15 1.4855 1.5431 1.5957 1.6586 1.7206 1.7802 1.8371 1.8943 1.9488 2.0001 2.0958 2.1690 2.2328 2.20 1.4554 1.5127 1.5664 1.6204 1.6740 1.7258 1.7806 1.8402 1.8987 1.9555 2.0552 2.1301 2.1935 2.25 1.4150 1.44699 1.5226 1.5777 1.6329 1.6865 1.7372 1.7878 1.8433 1.9040 2.0099 2.0901 2.1581 2.30 1.3873 1.4247 1.4682 1.5179 1.5694 1.6208 1.6720 1.7232 1.7753 1.8261 1.9346 2.0186 2.0904 2.35 1.3736 1.4129 I1.4481 1.4813 1.5248 1.5780 1.6287 1.6788 1.7298 1.7799 1.8700 1.9537 2.0300 2.40 1.3682 1.4092 1.4463 1.4826 1.5184 1.5536 1.5971 1.6412 1.6857 1.7338 1.8266 1.9006 1.9744 2.50 1.3118 1.3522 1.3886 1.4247-1.4597 1.4929 1.5247 1.5611 1.5980 1.6357 1.7235 1.7944 1.8684 2.60 1.3482 1.3890 1.4286 1.4666 1.5019 1.5355 1.5683 1.6033 1.6397 1.6759 1.7412 1.8161 1.8927 2.70 1.3061 1.3200 1.3403 1.3729 1.4135 1.4507 1.4858 1.5229 1.5610 1.5988 1.6677 1.7271 1.7927 2.80 1.2926 1.3122 1.3330 1.3550 1.3783 1.4029 1.4292 '1.4601 1.4918 1.5259 1.5883 1.6463 1.7021 2.90 1.2676 1.2856 11.3076 1.3386 1.3691 1.3980 1.4245 1.4490 1.4715 1.4921 1.5254 1.5576 1.5944 3.00 1.2627 1.2763 11.2923 1.3145 1.3384 1.3634 1.3912 1.4212 1.4489 1.4735 1.5116 1.5449 1.5792 3.10 1.2697 1.2905 11.3114 1.3377 1.3666 1.3954 1.4232 1.4509 1.4772 1.5019 1.5435 1.5725 11.5982 3.20 1.2577 1.2782 1.2970 1.3205 1.3466 1.3771 1.4075 1.4381 1.4674 1.4950 1.5418 1.5756 1.6054 3.30 1.2648 1.2915 1.3184 1.3475 1.3755 1.4002 1.4213 1.4403 1.4627 1.4862 1.5296 1.5630 1.5950 3.40 1.3270 1.3570 1.3857 1.4176 1.4493 1.4-777 1.5025 1.5248 1.5461 1.5745 1.6261 1.6678 1.7077 3.50 1.3535 1.3852 1.4160 1.4504 1.4860 1.5189 1.5483 1.5754 1.6000 1.6245 1.6806 1.7296 1.7768 3.60 1.3583 1.3699 1.3789 1.4083 1.4412 1.4738 1.5054 1.5363 1.5640 1.5906 1.6427 1.6861 1.7301 3.70 1.2550 1.2693 1.2789 1.2927 1.3109 1.3355 1.3668 1.4031 1.4392 1.4731 1.5329 1.5795 1.6220 3.80 1.1915 1.2043 11.2122 1.2200 1.2355 1.2576 1.2852 1.3189 1.3538 1.3871 11.4468 1.4938 1.5368 3.90 1.1691 1.1850 11.1975 1.2094 1.2209 1.2328 1.2458 1.2711 1.3001 1.3292 11.3899 1.4387 1.4838 4.00 1.1714 1.1834 11.1961 1.2087 1.2207 1.2334 1.2475 1.2638 1.2837 1.3052 1.3437 1.3790 1.4266 4.10 1.1339 1.1498 1.1652 1.1812 1.1959 1.2099 1.2241 11.2401 1.2591 1.2807 1.3240 1.3577 1.3842 4.20 11.1358 1.1361 1.1367 1.1410 1.1462 1.1522 1.1613 1.1750 1.1898 1.2061 1.2441 1.2808 1.3108 4.30 11. 1947 1.2008 1.2101 1.2195 1.2283 1.2365 1.43 1.2492 1.2575 1.2683 1.2917 1.3 174 136 4.40 1.2104 L.2222 1.2321 1.2409 1.2485 1.2550 1.29 1.2630 11.2669 1.2710 1.2814 11.2995 135 4.50 1.2000 1.2113 1.2216 1.2312 1.2394 1.2464 1.218 12557 1.-2600 1.64 1272

.70 127

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 134 of 349 Date: 08/27/03 4.60 1.174S 1.1857 1.1965 1.2069 1.2162 1.2245 1.2314 1.2387 1.2459 1.2526 1.2636]

1.2797 1.2969 4.70 1.1842 1.2014 1.2179 1.2344 1.2495 1.2628 1.2741 1.2840 1.2936 1.3027 1.3237 1.3453 1

.3664 I 4.80~ 1.1870 1.2040 1.2231 1.2429 1.2626 1.2809 1.2980 1.3147 1.3297 1.3422 1.3619 1.3815 1.4019 4.90 1.1821 1.1976 1.2124 1.2296 1.2488 1.2680 1.2865 1.3049 1.3220 1.3368 1.3611 1.3821 1.4025 5.00 1.1760 1.1893 1.2037 1.2181 1.2338 1.2503 1.2678 1.2864 1.3044 1.3208 1.3493 1.3741 1.3979 5.10 1.1924 1.2068 1.2188 1.2297 1.2439 1.2589 1.2753 1.2933 1.3112 1.3284 1.3605 1.38X9 1.4159 5.20 1.2165

-. 12285 1.2413 1.2537 1.2640 1 1.2723 1 1.2821 1.2950 1 1.3095 1.3250 1.3565' 368 1.4171 A.'0t I.

A -- A t-*--AI C n e I

A ls..

I I

5.40 I.2461

- 1.256U0 1.265 1:.285 '-

1.300 r 4

'I. 13220 1.330 L'

-1 404 1.3507 I.37i.

1 41 1iL.4452 5.60 1.1517 1.1643 1.1789 1.1944 1.2078 1.2183 1.2259 1.2309 1.2331 1.2337 1.2322 1.2276 1.2299 5.80 1.0982 1.1072 1.1149 1.1258 1.1434 1.1599 1.1751 1.1895 1.2012 1.2103 1.2232 1.2310 1.2372 6.00 1.0641 1.0712 1.0803 1.0921 1.1094 1.1271 1.1444 1.1618 1.1771 1.1899 1.2100 1.2242 1.2359 6.20 1.0987 1.0989 1.1013 1.1076 1.1142 1.1209 1.1277 1.1422 1.1552 1.1669 1.1869 1.2007 1.2106 6.40 1.1247 1.1318 1.1373 1.1426 1.1482 1.1535 1.1585 1.1643 1.1714 1.1822 1.2032 1.2207 1.2361 6.60 1.0991 1.1047 1.1080 1.1103 1.1189 1.1274 1.1353 1.1432 1.1507 1.1573 1.1688 1.1772 1.1838 6.80 I.&57 1.1049 1.1117 1.1162 1.1186 1.1201 1.1210 1.1210 1.1200 1.1205 1.1328 1.1431 1.1516 7.00 1.0829 1.0908 1.1003 1.1104 1.1177 1.1226 1.1260 1.1306 1.1355 1.1400 1.1498 1.1610 1.1736 7.20 1.1081 1.1133 1.1185 1.1232 1.1275 1.1306 1.1325 1.1333 1.1363 1.1437 1.1587 1.1724 1.1856 7.40 1.1132 1.1165 1.1188 1.1216 1.1267 1.1325 1.1373 1.1416 1.1456 1.1492 1.1555 1.1593 1.1613 7.60 1.1109 1.1172 1.1220 1.1260 1.1307 1.1362 1.1425 1.1494 1.1556 1.1605 1.1681 1.1730 1.1766 7.80 1.0950' 1.0941 1.0922 i.0921 1.0981 1.1043-

't'-lS 1.1204

'. 12gA 1.1351

- 1A467.

1.1567 1.1651 8.00 1.0802 1.0799 1.0798 1.0783 1.0765 1.0758 1.0790 1.0832 1.0887 1.0941 1.1029 1.1105 1.1177 8.50 1.0851 1.0892 1.0927 1.0945 1.0949 1.0950 1.0949 1.0946 1.0940 1.0935 1.0932 1.0937 1.0964 9.00 1.0889 1.0894 1.0902 1.0942 1.1020 1.1095 1.1161 1.1220 1.1274 1.1329 1.1429 1.1510 1.1595 9.50 1.1346 1.1382 1.1409 1.1442 1.1482 1.1524 1.1589 1.1673 1.1753 1.1835 1.1982 1.2102 1.2213 10.00 1.1765 1.1821 1.1843 1.1848 1.1836 1.1821 1.1811 1.1817 1.1848 1.1891 1.2033 1.2210 1.2414

. 4.

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 135 of 349 Date: 08/27/03 9.3 Step 3: Select a Subset of Spectral Periods The purpose of using a subset of periods is to limit the number of periods for which the probabilistic seismic hazard analysis needs to be run. In a typical PSHA based on smooth attenuation relations, about 15 periods spaced approximately equally on a log period axis

.are used. Since the site-specific site.response is not. as* smooth as attenuation relations, a finer period sampling is needed to adequately represent the site-specific soil effects.

For the PHSA, a subsets of 30 spectral periods were chosen to represent the full set of 152 spectral periods for each profile. The subset of selected periods is shown by the circles Figures 9-1 to 9-9. These periods were selected to adequately capture resonance peaks that are significant and are systematic over a range of input ground motion levels.

The selecteL.p~eriodls are listed in Table 7-12.

~

Table 7-12. Subset of periods representative of the full site response.

Index Period (sec) l 0.01 2

0.03 3

0.05 4

0.07 5

0.10 6

0.12 7

0.15 8

0.17 9

0.20 10 0.25 11 0.30 12 0.35 13 0.40 14 0.50 15 0.60 16 0.70 17 0.80 18 0.90 19 1.00 20 1.20 21 1.50 22 1.70 23 2.00 24 2.50 25 3.00 26 3.50 27 4.00 28 5.00 29 7.00 30 10.00

Calc Number (iEO.BI{BP.03.02 Rev Number: 0 Sheet Number: 136 of 349 Date: 08/27/03

10.

I-T

-02g

~~

~~~

~~~

~0.49

-O.6g

-0.7g 141-.iA2 I

I~~~~~~~Ijo 1i6g 11111 1

1 III' Hid o

~~~~0.7g 0.1

~~~~~~~~~~~~~~~~~~1.4 n

n 4~~r-uj1

~rITT f

Perlod (sec)

Figure 7-1. Amp factors for M=6.0, median soil profile.

Calc Number: GEO.HBIP.03.02 Rev Number 0 Sheet Number 137 of 349 Date: 08/27/03 I I l

-0 9

.2g liig

~~ I ~~~

0.49 I il l~ji 0.5g 0.69

-0.89 I I~~~l 1.09o

.11

[II

-12g llit~~

-1.6g III i~fl o 0.7g 1T1TII1-

~o 1.4g Period (see)

Figure 7-2. Amp factors for M=7.0, median soil profile.

Calc Number: GEO-HBIP.03.02 Rev Number: 0 Sheet Number 138 of 349 Date: 08/27/03

~~ ~II O.lg

-02g X

IW18 Iiij

-O0.7g liii~ in I I

~~~o 0.7g itt 0~

1.4g b-C)

.0 9t Period (sec)

Figure 7-3. Amp factors for M=7.8, median soil profile.

Calc Number. GEO.HBIP.03.02 Rev Number 0 Sheet Number. 139 of 349 Date: 08/27/03 I

~~~~~02g

_~~~

1 0 <

I

]

! X g ! 2 1

t Xf~I I

l

$ F~~~~ll.;

1I,,'S

.~~~I 111 l I I ll X I

tl I Iii 11i

! li 1

-O.ag lOg oO.Bg 10ll l11 1!

al !!! A A l Ag 10 Period (sac)

Figure 74. Amp factors for M=6.0, lower soil profile.

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number. 140 of 349 Date: 08/27/03 ii iii~~~~

2

-~ O.Ig

~~ 11~!!

I ~~

21 02g I

I 2~~~~~~~04

-O.F~g I

I I

I 2211

-~~~~

O.g 0.1 I.

a 1.4g~~~

I 0

0.1~~~~~~Hi1f I I I 1111 Perio I sec1IU I

Figur 7-5 Am fcorIorM7,loe soil11 1epe

Cale Number: G3EO.HBIP.03.02 Rev Number. 0 Sheet Number. 141 of 349 Date: 08/27/03

~~~~~

I ~ ~

~

~

~

OI

'I II~i

'111111

-O2g I '

~~~~~~~~~~~~~0.49 1%

~~~~0.6g LI

~~~~~~~~~~O.Bg

-~~~I O.2g Rilg 0.1 i~~~~~~~~

IJgi Period (sec)

Figure 7-6. Amp factors for M=7.8, lower soil profile.

Cale Number: GEO.BBIP.03.02 Rev Number 0 Sheet Number: 142 of 349 Date: 08/27/03 11111

-~~~~~~~02g

~~III ill

-~~~~~05g

-0.7g 0.8g 111:1 eio Sect higure 7-7.

Amp factors for M=6 upper soil profile.12g 0.1 o

10.141 Period (sec)

Figure 7-7. Amp factors for M=6.0, upper soil profile.

Cale Number: GEOMEBIIP.03.02 Rev Number. 0 Sheet Numbers 143 of 349 Date: 08/27/03 io_~~~~~~i 1111:21

~

~

~

~

~

~

OI I

~~l!~i 1

i~~i-02 1111111 ~

-0.

I

~~-

0.6g

' f~~~fJ;~~~J I

~-

1.4g I

I~~~~~~~~~~

1.6g ii ii;Ij~~~~~~~~~~~~

oO.lg 1K

' *I lid oO~~~~~0

.7g 0.1~~~~~~.

I Period (Sec)

Figure 7-8. Amp factors for M=7.0, upper soil profile.

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 144 of 349 Date: 08/27/03 1o 2

2..

Zs 3

L 0.7g 0..~~~~~~~~~~~~~~~~~~~08 LT~~

i'111 11WIO Ii Iii

I~~~~IIII~~'I 11111111 A

0A or t

~

ttii rt-T h

1.4g Perod (sec)

Figure 7-9. Amp factors for M=7.8, upper soil profile.

Calc Number: GEO.HBIP.03.02 Rev Number 0 Sheet Number: 145 of 349 Date: 08/27/03

10. RESULTS AND CONCLUSIONS The input rock spectra values at the-selected 30 spectral periods (from Tables 9-1 to 9-3) are listed in Tables 10-1 a, b, and c. The average site-specific soil amplification factors for each profile and each magnitude are listed in Tables 10-2 to 10-4. To use these amplification factors for a given.rock spectra acceleration at a selected spectral period, the rock spectral values (Tables 10-la, b, c) define the x-axis values and the soil amplification values (Tables 10-2 to 10-4) define the y-axis values. Linear interpolation should be used to compute the site amplification for the desired rock spectral acceleration level. For spectral acceleration less than the minimum value given in Table 10-1, the amplification should be set a the value for the minimum ground motion and for spectral accelerations greater than the largest value in Table 10-1, the amplification should be set at the value for the largest ground motion.

.Similarly, for the. magnitude interpolatiQp,.for magnitudes. between 6.0 and 7.8, linear interpolation should be used between the interpolated values for the M6, M7, and M7.8 cases. For magnitudes less than 6.0, the M6 value should be used. For magnitudes greater than 7.8, the M7.8 values should be used.

As an example, consider a magnitude 6.4 earthquake with a rock spectral acceleration of 0.4g at a period of 1.0 sec with the median soil profile. Reading the 1.0 sec values from Tables 10-la and 10-2a gives the values shown in Figure 10-1 for M=6 and M=7. Using linear interpolation, the site amplification is 2.06 for M=6. Reading the 1.0 sec values from Table 10-lb and 10-2b gives the values shown in Figure 10-1 for M=7. Using linear interpolation, the site amplification is 1.82 for M=7. Finally, using linear interpolation on the interpolated site amplifications for M6 and M7 leads to an amplification factor of 1.96 for M=6.4.

These amplification factors are applicable to hard rock spectra (Vs - 5000 ft/sec). Therefore, the generic "soft-rock" ground motions from attenuation relations used in California need to be scaled for hard rock conditions before applying these amplification factors.

The final soil spectra, computed using these amplification factors must be checked for the requirement that the spectral shape not fall below the empirical shape listed in Table 10-5. If the computed soil spectrum falls below this empirical shape, then the soil spectrum must be increased so that this requirement is met (Assumption 3.2)

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 146 of 349 Date: 08/27/03 A: '.

I I

-...~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~...

1.4-I. _________
  • 1-7 I
  • s_.._!

t;2..'-,

4-4 I~ ~ ~~.....

I 1

I

~~~~~~~~~~ ~~~~

~~

.t

...j.

  • I 0I -

~C2 0 ~ 4 ~ : 6 0.8 I:,,' !.

I2.

Figure 10-1. Example for interpolation of site amplification factors.

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 147 of 349 Date. 08/27/03 Table 10-la.

nput Rock Spectra Acceleration for M=6.0__

Per PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA (sec) 0.1g 0.2g 0.3g 0.4g I

.5a 0.6g 0.7g 0.8g O.9g j.Og 1.2g I.4 1.6g 0.01 0.1000 0.2000 0.3000 0.4000 0.5000 0.6000 0.7000 0.8000 0.9000 1.0000 1.2000 1.4000) 1.6000 0.03 0.0933 0.1866 0.2799 0.3732 0.4665 0.5598 0.6531 0.7464 0.8397 0.9330 1.1196 1.3063 1,4929 0.05 0.1159, 0.2318

.0.3477.0.4637 0.5796 0.6955 0.8114 0.9273 1.0432 1.1591 1.3910 1.6228 1.8546 0.07 0.1425 0.2849 0.4274 0.5698 10.7123 0.8548 0.9972 11.1397 1.2821 1.4246 1.7095 1.9944 2.2794 0.10 0.1772 0.3543 0.5315 0.7086 0.8858 1.0630 1.2401 1.4173 1.5945 1.7716 2.1259 2.4803 2.8346 0.12 0.1950 0.3900 0.5850 0.7800 0.9750 1.1700 1.3649 1.5599 1.7549 1.9499 2.3399 2.7299 3.1199 0.15 0.2078 0.4157 0.6235 0.8313 1.0391 1.2470 1.4548 1.6626 1.8704 2.0783 2.4939 2.9096 3.3252 0.17 0.2085 0.4170 0.6255 0.8340 1.0425 1.2510 1.4595 1.6680 1.8765 2.0850 2.5020 2.9190 3.3360 0.20 0.2109 0.4218 0.6327 0.8436 1.0545 1.2654 1.4762 1.6871 1.8980 2.10S9 2.5307 2.9525 3.3743 0.25 0.1931 0.3863 0.5794 0.7726 0.9657 1.1589 1.3520 1.5452 1.7383 1.9314 2.3177 2.7040 3.0903 0.30 0.1741 0.3483 0.5224 0.6966 0.8707 1.0449 1.2190 1.3931 1.5673 1.7414 2.0897 2.4380 2.7863 0.35 0.1577 0.3154 0.4731 0.6308 0.7885 0.9462 1.1039 1.2616 1.4193 1.5770 1.8924 2.2078 2.5232 0.40 0.1431r. 0.2861 0.4292 0.5722- 0.7153 0.8583..,-,L0014 1.1444 1.2875 1.4306 1.7J67 2.0028 2.2889 0.50 0.1106 0.2212 0.3318 0.4425 0.5531 0.6637 0.7743 0.8849 0.9955 1.1061 1.324-1.5486 1.7698.

0.60 0.0900 0.1801 0.2701 0.3601 0.4501 _0.5402 0.6302 0.7202 0.8102 0.9003 1.0803 1.2604 1.4404 0.70 0.0776 0.1552 0,2329 0.3105 0.3881 0.4657 0.5433 0.6210 0.6986 0.7762 0.9315 1.0867 1.2419 0.80 0.0678 0.1357 0.2035 0.2713 0.3392 0.4070 0.4748 0.5427 0.6105 0.6783 0.8140 0.9496 1.0853 0.90 0.0573 0.1145 0.1718 0.2291 0.2864 0.3436 0.4009 0.4582 0.5155 0.5727 0.6873 0.8018 0.9164 1.00 0.0529 0.1058 0.1587 0.2116 0.2645 0.3174 0.3703 0.4232 0.4760 0.5289 0.6347 0.7405 0.8463 1.20 0.0401 0.0802 0.1203 0.1604 0.2004 0.2405 0.2806 0.3207 0.3608 0.4009 0.4811 0.5612 0.6414 1.50 0.0290 0.0580 0.0870 0.1160 0.1450 0.1740 0.2030 0.2320 0.2610 0.2900 0.3480 0.4060 _0.4640 1.70 0.0246 0.0493 0.0739 0.0986 0.1232 0.1479 0.1725 0.1971 0.2218 0.2464 0.2957 0.3450 0.3943 2.00 0.0190 0.0380 0.0570 0.0760 0.0951 0.1141 0.1331 0.1521 0.1711 0.1901 0.2281 0.2662 0.3042 2.50 0.0131 0.0261 0.0392 0.0523 0.0654 0.0784 0.0915 0.1046 0.1177 0.1307 0.1569 0.1830 0.2092 3.00 0.0099 0.0199 0.0298 0.0398 0.0497 0.0597 0.0696 -0.0796 0.0895 0.0994 0.1193 0.1392 0.1591 3.50 0.0072 0.0144 0.0217 0.0289 0.0361 0.0434 0.0506 0.0579 0.0651 0.0723 0.0867 0.1012 0.1157 4.00 0.0054 0.0108 0.0163 0.0217 0.0271 0.0325 0.0379 0.0434 0.0488 0.0542 0.0650 0.0759 0.0867 5.00 0.0034 0.0068 0.0103 0.0137 0.0171 0.0205 0.0239 0.0273 0.0308 0.0342 0.0410 0.0479 0.0;47 7.00 0.0017 0.0033 0.0050 0.0067 0.0084 0.0100 0.0117 0.0134 0.0151 0.0167 0.0201 0.0234 0.0268 10.00 0.0007 0.0013 0.0020 0.0027 0 0033 0.0040 0.0046 0.0053 0.0060 0.0066 0.0080 0.0093 0.0106

Calc Number: GEO.HB IP.03.02 Rev Number: 0 Sheet Number: 148 of 349 Date: 08/27/03 Table 10-lb. Input Rock Spectra Acceleration (.) for M-7.0 Per PGA PGA GA PGA G

PGA PGx A PGA PGA PGA PGA PGA PGA (sec) 0.lg 0.2 0.3g 0.4g O.Sg 0.6g 0.7g 0.82 0.9g 1.02 1.2g 1.4g 1.6fi 0.01 0.1000 0.2000 0.3000 0.4000 0.5000 0.6000 0.7000 0.8000 0.9000 1.0000 1.2000 1.4000 1.6000 0.03 0.0986 0.1973 0.2959 0.3946 0.4932 0.5919 0.6905 0.7892 0.8878 0.9865 1.1838 1.3811 1.5784

-*-0.05 0.1242 0.2484 _0.3726 0.4968

.D.6210 0.7452 086Q4 0.9936 1.11.78. 1.2420 1.4903 I.73-S7 1.9871 0.07 0.1506 0.3012 0.4517 0.6023 0.7529 0.9035 1.0541 1.2046 1.3552 1.5058 1.8069 2.1081 2.4093 0.10 0.1825 0.3649 0.5474 0.7299 0.9124 1.0948 1.2773 1.4598 1.6423 1.8247 2.1897 2.5546 2.9196 0.12 0.2014 0.4027 0.6041 0.8055 1.0069 1.2082 1.4096 1.6110 1.8123 2.0137 2.4164 2.8192 3.2219 0.15 0.2183 0.4367 0.6550 0.8734 1.0917 1.3100 1.5284 1.7467 1.9651 2.1834 2.6201 3.0568 3.4934 0.17 0.2199 0.4397 0.6596 0.8795 1.0994 1.3192 1.5391 1.7590 1.9789 2.1987 2.6385 3.0782 3.5180 0.20 0.2257 0.4515 0.6772 0.9030 1.1287 1.3544 1.5802 1.8059 2.0316 2.2574 2.7089 3.1603 3.6118 0.25 0.2185 0.4369 0.6554 0.8738 1.0923 1.3107 1.5292 1.7476 1.9661 2.1845 2.6214 3.0583 3.4952 0.30 02081 0.4161 0.6242 0.8322 1.0403 1.2483 1.4564 1.6644 1.8725 2.0805 2.4966 2.9127 3.3289 0.35 0.1959 0.3917 0.5876 0.7834 0.9793 1.1752 1.3710 1.5669 1.7627 1.9586 2.3503 2.7420 3.1338 OAO... 0.1777 O 3ss4_ O5331 0.710&8.0.8884 11.0661 1.2438.

1.4215 1.5992

.1.7769 2.1323.. 2.4876.. 2.8430 0.50 0.1550 0.3100 0.4650 0.6201 0.7751 0.9301 1.0851 1.2401 1.3951 1.5502 1.8602 2.1702 '2.4803 0.60 0.1305 0.2610' 0.3914 0.5219 0.6524 0.7829 0.9133 1.0438 1.1743 1.3048 1.5657 1.8267 2.0876 0.70 0.1096 0.2193 0.3289 0.4386

'0.5482 0.6578 0.7675 0.8771 0.9867 1.0964 1.3157 11.5349 1.7542 0.80 0.0960 0.1921 0.2881 0.3841 0.4801 0.3762 0.6722 0.7682 0.8642 0.9603 1.1523 1.3444 1.5364 0.90 0.0844 0.1688 0.2532 0.3375 0.4219 0.5063 0.5907 0.6751 0.7595 0.8438 1.0126 1.1814' 1.3501 1.00 0.0744 0.1489 0.2233 0.2978 0.3722 0.4467 0.5211 0.5956 0.6700 0.7445 0.8933 1.0422 1.1911 1.20 0.0603 0.1206 0.1808 0.2411 0.3014 0.3617 0.4219 0.4822 0.5425 0.6028 0.7233 0.8439 0.9644 1.50 0.0458 0.0916 0.1375 0.1833 0.2291 0.2749 0.3208 0.3666 0.4124 0.4582 0.5499 0.6415' 0.7332 1.70 0.0358 0.0716 0.1074 0.1432 0.1790 0.2148 0.2506 0.2864 0.3222 0.3580 0.4297 0.5013 0.5729 2.00- 0.0286 0.0572 0.0858 0.1143 0.1429 0.1715 0.2001 0.2287 0.2573 0.2858 0.3430 0.4002 0.4573 2.50 0.0202 0.0403 0.0605 0.0806 0.1008 0.1210 0.1411 0.1613 0.1815 0.2016 0.2419 0.2823 0.3226 3.00 0.0157 0.0314 0.0471 0.0628 0.0785

.0.0942 0.1099 0.1255 0.1412 0.1569 0.1883 0.2197 0.2511 3.50 0.0116 0.0233 0.0349 0.0465 0.0582 0.0697 0.0813 0.0929 0.1046 0.1162 0.1395 0.1627 0.1859 4.00 0.0093 0.0185 0.0278 0.0370 0.0463 0.0555 0.0648 0.0740 0.0833 0.0925 0.1110 0.1295 0.1480 5.00 0.0065 0.0130 0.0194 0.0259 0.0324 0.0389 0.0454 0.0519 0.0583 0.0648 0.0778 0.0908 0.1037 7.00 0.0031 0.0063 0.0094 0.0125 0.0156 0.0188 0.0219 0.0250 0.0281 0.0313 0.0375 0.0438 0.0500 10.00 0.0014 0.0029 0.0043 0.0058 0.0072 0.0087 0.0101 0.0116 0.0130 0.0145 0.0174 0.0203 0.0232

Calc Number: GEO.HB[P.03.02 Rev Number: 0 Sheet Number: 149 of 349 Date: 08/27/03 Table 10-ic.

Rock Sp ectra Acceleration () for M=7.8 Per PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA (sec) 0.12 0.2g 0.3g 0.4a 0.5g 0.6g 0.7g 0.82 0.92 I.Og 1.2gz t.4g 1.6g 0.01 0.1000 0.2000 0.3000 0.4000 0.5000 0.6000 0.7000 0.8000 0.9000 1.0000 1.2000 1.4000 1.6000 0.03 0.0992 0.1984 0.2976 0.3969 0.4961 0.5953 0.6945 0.7937 0.8929 0.9921 1.1906 1.3890 1.5874 0.05.

0.1412 0.2825

.A0.437 0.5650 0.7062..o0,8474 0.9887

.1.1299 1.2712 1.4124..1.6949 I1.9774. :.2599 0.07 0.1702 0.3404 0.5106 0.6808 0.8510 1.0212 1.1914 1.3616 1.5318 1.7020 2.0424 2.3828 2.7232 0.10 0.1950 0.3900 0.5850 0.7800 0.9750 1.1700 1.3649 1.5599 1.7549 1.9499 2.3399 2.7299 3.1199 0.12 0.2042 0.4084 0.6127 0.8169 1.0211 1.2253 1.4296 1.6338 1.8380 2.0422 2.4507 2.8591 3.2676 0.15 0.2196 0.4392 0.6589 0.8785 1.0981 1.3177 1.5374 1.7570 1.9766 2.1962 2.6355 3.0747 3.5140 0.17 0.2252 0.4505 0.6757 0.9010 1.1262 1.3514 1.5767 1.8019 2.0272 2.2524 2.7029 3.1534 3.6039 0.20 0.2290 0.4580 0.6870 0.9161 1.1451 1.3741 1.6031 1.8321 2.0611 2.2901 2.7482 3.2062 3.6642 0.25 0.2283 0.4565 0.6848 0.9131 1.1414 1.3696 1.5979 1.8262 2.0544 2.2827 2.7393 3.1958 3.6523 0.30 0.2196 0.4391 0.6587 0.8782 1.0978 11.3174 1.5369 1.7565 1.9761 2.1956 2.6347 3.0739 3.5130 0.35 0.2078 0.4155 0.6233 0.8311 1.0388 1.2466 1.4544 1.6621 1.8699 2.0777 2.4932 2.9088 3.3243 0.0. 041998 0.3996

.0.f994 0.7992 0.9990. 1,1988 1.3986,.j.5rJ4: 1.7982 1.9980,2.3976 2.7972, 23.1968 0.50 0.1743 0.3487 0.5230 0.6973 0.8717-1.0460 1.2204 1.3947 1.5690 1.7434 2.0920 2.4407 2.7894 0.60 0.1487 0.2974 0.4460 0.5947 0.7434 0.8921 1.0407 r.1894 1.3381 1.4868 1.7841 2.0815 2.3789 0.70 0.1296 0.2592 0.3888 0.5184 0.6479 0.7775 0.9071 1.0367 1.1663 1.2959 1.5551 1.8143 2.0734 0.80 0.1211 0.2422 0.3633 0.4844 0.6055 0.7266 0.8478 0.9689 1.0900 1.2111 1.4533 1.6955 1.9377 0.90 0.1051 0.2102 0.3152 0.4203 0:5254 0.6305 0.7356 0.8407 0.9457 1.0508 1.2610 1.4712 1.6813 1.00 0.0981 0.1962 0:2943 0.3924 0.4905 0.5886 0.6867 0.7848 0.8829 0.9810 1.1772 1.3735 1.5697 1.20 0.0789 0.1579 0.2368 0.3157 0.3947 0.4736 0.5526 0.6315 0.7104 0.7894 0.9472 1.1051 1.2630 1.50 0.0632 0.1263 0.1895 0.2526 0.3158 0.3789 0.4421 0.5052 0.5684 0.6315 0.7578 0.8842 I.0105 1.70 0.0538 0.1076 0.1615 0.2153 0.2691 0.3229 0.3768 0.4306 0.4844 0.5382 0.6459 0.7535 0.8612 2.00 0.0462 0.0924 0.1386 0.1849 0.2311 0.2773 0.3235 0.3697 0.4159 0.4621 0.5546 0.6470 0.7394 2.50 0.0330 0.0659 0.0989 0.1319 0.1649 0.1978 0.2308 0.2638 0.2968 0.3297 0.3957 0.4616 0.5276 3.00 0.0262 0.0524 0.0786 0.1048 0.1310 0.1572 0.1834 0.2096 0.2358 0.2620 0.3144 0.3667 0.4191 3.50 0.0190 0.0381 0.0572 0.0762 0.0952 0.1143 0.1333 0.1524 0.1715 0.1905 0.2286 0.2667 0.3048 4.00 0.0174 0.0349 0.0523 0.0697 0.0871 0.1046 0.1220 0.1394 0.1569 0.1743 0.2092 0.2440 0.2789 5.00 0.0113 0.0226 0.0340 0.0453 0,0566 0.0679 0.0792 0.0905 0.1019 0.1132 0.1358 0.1584 0.1811 7.00 0.0069 0.0138 0.0208 0.0277 0.0346 0.041 0.0484 0.0553 0.0623 0.0692 0.0830 0.0969 0.1107 10.00 0.0029 0.0058 0.0087 0.0116 0144 173 0.0202 0.0231 0.0260 0.0289 0.0347 0.0404 0.0462

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 150 of 349 Date: 08/27/03 Table 10-2a. Amplification Factor for Median Profile, M=6.0 Per PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA (sec)

O.1R 0.22 0.3g 0.4O2o 0.5g2 02.7g 0.8g 0.9g LOR 1.2e 1.4 1.6e 0.01 1.7786 1.6002 1.4221 1.2761 1.1575 1.0643 1.0193 0.9764 0.9386 0.9077 0.8495 0.7864 0.7152 0.03 1.9870 1.7743 1.5656 1.3996 1.2670 1.1630 1.1072 1.0583 1.0173 0.9837 0.9203 0.8518 0.7740 0.05 1.8128 1.5808 1.3769 -1.2195 1.0919 0O9883- 0.9304 0.8814 G:Q.8372 0.8055

.0.7531. 0.6967 0.6329 0.07 1.8296 1.4773 1.2767 1.1057 0.9671 0.8670 0.8075 0.7606 0.7190 0.6784 0.6233 0.5788 0.5276 0.10 2.0215 1.6758 1.4390 1.2689 1.1234 0.9915 0.8831 0.7938 0.7180 0.6687 0.5890 0.5261 0.4700 0.12 2.2937 1.8815 1.6211 1.4292 1.2691 1.1252 0.9998 0.8908 0.7954 0.7059 0.5956 0.5248 0.4652 0.15 2.1766 1.9983 1.7477 1.5660 1.4311 1.2996 1.1736 1.0623 0.9651 0.8766 0.7341 0.6412 0.5652 0.17 2.3690 2.1737 1.8990 1.6871 1.5430 1.4481 1.3505 1.2473 1.1476 1.0452 0.8902 0.7720 0.6707 0.20 2.5966 2.2572 2.0518 1.9051 1.7725 1.6604 1.5676 1.4717 1.3734 1.2673 1.0741 0.9241 0.8059 0.25 2.5695 2.5336 2.4170 2.2852 2.1465 1.9973 1.8517 1.7175 1.6045 1.4930 1.2978 1.1291 0.9832 0.30 2.2454 2.3315 2.3360 2.2808 2.1835 2.1106 2.0552 1.9932 1.9401 1.8739 1.6922 1.4852 1.2931 0.35 2.0227 1.9042 1.8720 1.8786 1.8768 1.8773 1.8769 1.8726 1.8644 1.8461 1.7886 1.6875 1.5502 0.40 2.1784 1.9790 1.8482; 4-7.5j

-1.6777 1.6196 1...J5881 1.5685-1.S510 1.5269 1.5129.1.5075 1.4667.

0.50 2.3135 2.2683 2.1865 2.0986 1.9986 1.9099 1.8420 1.7780 1.7198 1.6569 1.5530 1.4590 1.3738 0.60 1.8813 1.9206 1.9377 1.9464 1.9380 1.9202 1.9016 1.8747 1.8416 1.7953 1.6968 1.6164 1.5197 0.70 1.6460 1.6640 1.6773 1.6964 1.7150 1.7340 1.7469 1.7546 1.7588 1.7577 1.7518 1.7437 1.6970 0.80 1.9230 1.9021 1.8557 1.8172 1.7905 1.7698 1.7500 1.7352 1.7265 1.7227 1.7208 1.7162 1.7015 0.90 2.2347 2.1964 2.1326 2.0824 2.0390 1.9935 1.9478 1.9041 1:8634 1.8254 1.7698 1.7380 1.7062 1.00 22966 2.2830 2.2427 2.2083 2.1729 2.1283 2.0803 2.0352 1.9949 1.9586 1.8955 1.8370 1.7808 1.20 2.7893 2.7544 2.6844 2.6249 2.5645 2.4915 2.4263 2.3601 2.3045 2.2638 2.1954 2.1324 2.0680 1.50 2.5448 2.6057 2.6561 2.6935 2.7215 2.7440 2.7582 2.7646 2.7633 2.7555 2.7209 2.6630 2.5816 1.70 2.3771 2.4253 2.4685 2.5188 2.5665 2.6072 2.6412 2.6696 2.6922 2.7110 2.7271 2.7215 2.6904 2.00 2.1339 2.1772 2.2117 2.2375 2.2599 2.2798 2.3125 2.3468 2.3802 2.4154 2.5002 2.5836 2.6678 2.50 1.8054 1.8417 1.8671 1.8857 1.9169 1.9497 1.9819 2.0134 2.0450 2.0781 2.1420 2.2059 2.2848 3.00 1.6092 1.6314 1.6494 1.6620 1.6720 1.6811 1.6938 1.7087 1.7240 11.7403 1.7791 1.8316 1.8781 3.50 1.5239 1.5528 1.5764 1.6004 1.6225 1.6443 1.6646 1.6836 1.7020 1.7206 1 1.7557 1.7899 1.8224 4.00 1.5293 1.5371 1.5595 1.5797 1.5996 1.6189 1.6380 1.6567 1.6741 1.6907 1.7197 1.7501 1.7876 5.00 1.5664 1.5761 1.5814 1.5846 1.5879 1.5904 1.5935 1.5970 1.6013 1.6065 1.6295 1.6571 1.6812 7.00 1.3910 1.4024 1.4129 1.4211 1.4264 1.4304 1.4333 1.4353 I1.4368 1.4379 1.4380 1.4341 1.4276 10.00 1.4817

  • 1.4893 1.4967 1.5038 1.5089 1.5107 1.5119 1.5123 1.5125 1.5120 1.5183 1.5295 1.5358

Cal Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 151 of 349 Date: 08/27/03 Table 10-2b. AmDpl ication Factor for Median Profile, M=7.0 Per PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA (sec)

O.lgg 0.2g 0.3e 0.4g 0.5g 0.6g 0.7g 0.8g 0.9g I.Og 1.2g 1.4g 1.6e 0.01 1.7101 1.5542 1.4053 1.2672 1.1531 1.0873 1.0262 0.9669 0.9117 0.8636 0.7886 0.7324 0.6763 0.03 1.7683 1.6061 1.4504 1.3051 1.1856 1.1135 1.0501 0.9891 0.9321 0.8822 0.8045 0.7466 0.6885 0.05 1.5404 1.3713-1.2130 1.0809 0.9749 0.9063 0.8532 :-0.8015 0.7541.

037124 0.6477.0.5.999

.0.5521 0.07 1.5073 1.1995 1.0306 0.9251 0.8486 0.7918 0.7395 0.6906 0.6459 0.6074 0.5462 0.5042 0.4621 0.10 1.6290 1.3287 1.0915 0.9221 0.8087 0.7265 0.6627 0.6073 0.5629 0.5288 0.4814 0.4408 0.3997 0.12 1.9462 1.4978 1.2038 1.0216 0.9000 0.8039 0.7155 0.6508 0.6008 0.5571 0.4825 0.4238 0.3798 0.15 2.0805 1.6550 1.3488 1.1455 1.0146 0.8939 0.7789 0.6832 0.6109 0.5608 0.4918 0.4316 0.3703 0.17 2.1190 1.7133 1.4530 1.1481 1.0782 0.9580 0.8683 0.7966 0.7268 0.6597 0.5399 0.4403 0.3800 0.20 2.2138 1.7324 1.4458 1.2493 1.1383 1.0300 0.9241 0.8424 0.7647 0.7073 0.6176 0.5168 0.4493 0.25 2.6223 2.3172 2.0782 1.8314 1.6061 1.3963 1.2363 1.0885 0.9709 0.9007 0.7677 0.6290 0.5535 0.30 2.1083 2.1104 2.0396 1.8788 1.7551 1.6320 1.5091 1.3822 1.2640 1.1618 0.9759 0.7939 0.6809 0.35 1.7322 1.6330 1.6081 1.5951 1.6489 1.6699 1.6615 1.6295 1.5728 1.4957 1.2947 1.0485 0.8716

>.-_0.4@i V 1.9201

_1.7709 l16705 1.5860 1,517.1 1.4570 1.4.138 1.3875 1.3547.jL O-10 1.2996 1.2053 1.0906 0.50 1.9544 1.8690 1.7731 1.6475 1.5297 1.4675 1.4110 1.3597 1.3098 1.2658 1.2249 1.1918 1.1367 0.60 1.7907 1.7411 1.7176 1.7166 1.7142 1.6852 1.6204 1.5418 1.4696 1.4030 1.3135 1.2631 1.2023 0.70 1.7026 1.6602 1.6353 1.6103 1.5886 1.5706 1.5517 1.5341 1.5004 1.4604 1.4003 1.3691 1.3327 0.80 1.6751 1.6291 1.6086 1.5815 1.5521 1.5353 1.5211 1.5078 1.4888 1.4755 1.4590 1.4378 1.4113 0.90 2.0282 1.9445 1.8698 1.7932 1.7205 1.6683 1.6298 1.5937 1.5640 1.5429 1.5077 1.4800 1.4525 1.00 2.1606 2.0556 1.9768 1.9052 1.8397 1.7864 1.7397 1.6985 1.6652 1.6393 1.6006 1.5708 1.5467 1.20 2.6592 2.5729 2.4969 2.4132 2.3134 2.2146 2.1207 2.0316 1.9575 1.8878 1.8006 1.7279 1.6740 1.50 2.3265 2.3710 2.3982 2.4094 2.4024 2.3812 2.3537 2.3178 2.2771 2.2345 2.1488 2.0601 1.9776 1.70 2.1798 2.2354 2.2955 2.3926 2.4782 2.5436 2.5839 2.5940 2.5867 2.5586 2.4798 2.3696 2.2786 2.00 1.9990 2.0821 2.1440 2.1959 2.2470 2.2973 2.3431 2.3824 2.4202 2.4539 2.4974 2.5171 2.5200 2.50 1.6905 1.7248 1.7507 1.7728 1.8041 1.8547 1.9002 1.9408 1.9909 2.0396 2.1205 2.1903 2.2446 3.00 1.5575 1.5908 1.6147 1.6317

.1.6522 1.6766 1.6991 1.7188 1.7367 1.7524 1.8056 1.8590 1.9196 3.50 1.3983 1.4531 1.4935 1.5264 1.5551 1.5798 1.6010 1.6198 1.6370 1.6512 1.6788 1.7111 1.7560 4.00 1.3570 1.3830 1.4061 1.4390 1.4722 1.5034 1.5321 1.5592 1.5847 1.6073 1.6466 1.6815 1.7073 5.00 1.2365 1.2594 1.2823 1.3062 1.3280 1.3475 1.3651 1.3809 1.3956 1.4081 1.4300 1.4484 1.4610 7.00 1.2150 1.2272 1.2384 1.2484 1.2561 1.2612 1.2648 1.2682 1.2715 1.2742 1.2773 1.2835 1.2962 10.00 1.3233 1.3204 0.9463 1.3181 1.3172 1.3179 1.3197 1.3233 1.3283 1.3338 1.3448 1.3604 1.3789

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 152 of 349 Date: 08/27/03 Table 10-2c. Amplification Factor for Median Profile, M=7.8 Per PCIA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA (sec) 0.1g 0.2g 0.3g 0.4g 0.6g 0.7g 0.82 0.9g2 1.0 1.2g 1.4a 1.62 0.01 1.6554 1.4777 1.3110 1.1554 1.0685 1.0211 0.9738 0.9356 0.9107 0.8756 0.7883 0.6932 0.6084 0.03 1.7049 1.5146 1.3407 1.1760 1.0851 1.0341 0.9849 0.9458 0.9209 0.8858 0.7974 0.7009 0.6149 0.05 I1.30V8-1.1215 0.9822.- 0.8430 0.7773-. 0.7347 0.6982 0.6700 0.6514 0.6264.4-5635 0.4951 0.4341 0.07 1.2965 0.9983 0.8692 0.7453 0.6619 0.6199 0.5875 0.5624 0.5458 0.5249 0.4721 0.4144 0.3631 0.10 1.5433 1.2275 0.9940 0.8369 0.7131 0.6346 0.5802 0.5419 0.5092 0.4814 0.4274 0.3721 0.3244 0.12 1.6635 1.3145 1.0741 0.8996 0.7708 0.6671 0.5975 0.5399 0.4958 0.4615 0.4059 0.3550 0.3108 0.15 1.8602 1.5537 1.2630 1.0298 0.8497 0.7318 0.6400 0.5611 0.4846 0.4404 0.3811 0.3330 0.2921 0.17 2.1221 1.7195 1.3901 1.1591 0.9852 0.8374 0.7173 0.6365 0.5701 0.5169 0.4279 0.3609 0.3116 0.20 2.0373 1.5904 1.4033 1.2672 1.1206 0.9937 0.8871 0.7954 0.7154 0.6484 0.5361 0.4445 0.3759 0.25 2.2817 2.1158 1.8273 1.5197 1.3056 1.1837 1.0789 0.9761 0.8744 0.8077 0.6870 0.5801 0.4901 0.30 2.1607 2.1814 1.9669 1.7206 1.5726 1.4321 1.2967 1.1514 1.0165 0.9216 0.7853 0.6633 0.5632 0.35 1.8239 1.7785 1.6964 1.6022 1.5658 1.5013 1.3841 1.2486 1.1335 1.0499 0.9122 0.7804 0.6747 0.40.

1;7.698-1.5687 1.4727

-1.4183 1.3914-137

.38070 0.9746 0.8609 0.50 2.0871 1.9070 1.6860 1.4950 1.3374 1.2235 1.1410 1.0833 1.0773 1.0731 1.0503 0.9821 0.8822 0.60 1.6679 1.7477 1.8337 1.8282 1.7402 1.6096 1.4837 1.3703 1.2867 1-2119 1.1087 1.0143 0.9002 0.70 1.6566 1.6279 1.6305 1.6190 1.6465 1.6438 1.6167 1.5727 1.5358 1.4908 1.3690 1.1970 1.0041 0.80 1.5938.

1.5708 1.5839 1.5705 1.5602 1.5463 1.5226 1.4946 1.4829 1.4706 1.4219 1.3179 1.1488 0.90 1.8526 1.7312 1.6469 1.5825 1.5297 14A814 1.4381 1.4174 1.4314 1.4351 1.4091 1.3292 1.2004 1.00 2.0390 1.9030 1.8063 1.6965 1.6099 1.5536 1.5103 1.4785 1.4647 I14493 1.4058 11.3463 1.2624 1.20 2.5977 2.4999 2.3954 2.2462 2.1219 2.0216 1.9339 1.8571 1.7983 1.7377 1.6096

.1.4688 1.3419 1.50 2.4217 2.5452 2.6067 2.5985 2.5617 2.5152 2.4441 2.3551 2.2656 2.1836 2.0135 1.8201 1.6220 1.70 2.2534 2.3776 2.5088 2.6151 2.7059 2.7521 2.7539 2.7169 2.6545 2.5604 2.3138 2.0977 1.9044 2.00 1.8752 1.9719 2.0695 2.1769 2.2711 2.3460 2.4039 2.4436 2.4645 2.4602 2.4504 2.3877 2.2693 2.50 1.5114 1.5641 1.6171 1.6945 1.7732 1.8519 1.9279 1.9946 2.0507 2.0943 2.1707 2.2289 2.2524 3.00 1.3759 1.4276 1.4698 1.5087 1.5438 1.5771 1.6086 1.6408 1.6751 1.7083 1.7766 1.8393 1.8873 3.50 1.5312 1.5845 1.6271 1.6710 1.7208 1.7661 1.8085 1.8491 1.8868 1.9215 1.9915 2.0593 2.1207 4.00 1.2463 1.2744 1.3030 1.3373 1.3677 1.4011 1.4443 1.4847 1.5215 1.5550 1.6218 1.6874 1.7489 5.00 1.2507 1.2819 1.3110 _ 1.3393 1.3645 1.3874 1.4094 1.4312 1.4514 1.4676 1.4899 1.5070 1.5402 7.00 1.1205 1.1279 1.1360 1.1449 1.1550 1.1658 1.1777 1.1894 1.2007 1.2111 1.2295 1.2451 1.2593 10.00 1.1837 1.1805 1.1858 1.1978 1.2136 1.2311 1.2502 1.2688 1.2850 1.2968 1.3104 1.3193 1.3303

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 153 of 349 Date: 08/27/03 Table 10-3a. Amplification Factor for Lower Profile, M=6.0 Per PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA (sec)

O.e 0.22 0.3e 0.4Q e

.50 0.6V 0.7e 0.8e 0.9E 1.0° 1.2Q 1.4 1.6e 0.01 1.5335 1.3705 1.2483 1.1519 1.0586 0.9701 0.8888 0.8151 0.7527 0.7095 0.6298 0.5582 0.5034 0.03 1.7150 1.51 12 1.3604 1.2525 1.1497 1.0528 0.9643 0.8845 0.8153 0.7687 0.6811 0.6026 0.5430

.0.05 1.5447 1.3123 1.1218 1.0262 0.9401 0.8614

-27884

-0.7232.0.6665. 0.6283 0.5558.

0.4901 0.4413 0.07 1.4400 1.1753 0.9807 0.8618 0.7795 0.7191 0.6636 0.6134 0.5705 0.5354 0.4689 0.4096 0.3671 0.10 1.7507 1.3860 1.0869 0.8936 0.7902 0.7104 0.6433 0.5857 0.5341 0.4883 0.4119 0.3549 0.3110 0.12 1.7860 1.4506 1.1431 0.9197 0.8022 0.7212 0.6569 0.6030 0.5554 0.5115 0.4301 0.3553 0.2984 0.15 2.0303 1.6496 1.3415 1.1132 0.9880 0.8985 0.8209 0.7409 0.6636 0.5945 0.4743 0.3878 0.3212 0.17 2.3793 1.9440 1.5981 1.3498 1.1744 1.0313 0.9129 0.8201 0.7390 0.6715 0.5612 0.4694 0.3930 0.20 2.4923 2.0136 1.6916 1.4862 1.3404 1.1987 1.0708 0.9724 0.8906 0.8190 0.6943 0.5872 0.5000 0.25 2.5782 2.1830 1.9234 1.7095 1.5213 1.3577 1.2245 1.1145 1.0270 0.9540 0.8252 0.7062 0.6201 0.30 2.7213 2.6243 2.4646 2.1882 1.8944 1.6609 1.4871 1.3536 1.2465 1.1537 1.0063 0.8642 0.7540 0.35 2.4637 2.5343 2.5073 2.4080 2.2519 2.0756 1.9009 1.7414 1.6006 1.4761 1.2698 1.0829 0.9426

--040 2.0119,.2.0213N-2.0793 2.1310 0.2.1218 2.0813. -t2.0301 1.9764 1.9150

.1.8358 1.6369 r4148 1.2296 0.50 2.0735 1.9910 1.9191 1.8493 1.7792 1.7176 1.6729 1.6477 1.6299 1.6075 1.5602 1.4794 1.4033 0.60 2.1605 2.1176 2.0547 1.9702 1.8901 1.8107 1.7288 1.6517 1.5879 1.5308 1.4339 1.3508 1.2979 0.70 1.9545 2.0121 2.0703 2.0989 2.1148 2.0857 2.0202 1.9398 1.8588 1.7648 1.5605 1.3857 1.2952 0.80 1.7403 1.7602 1.7939 1.8307 1.8494 1.8554 1.8609 1.8631 1.8518 1.8222 1.7420 1.6422 1.5589 0.90 1.8606 1.8049 1.7735 1.7616 1.7708 1.7776 1.7846 1.7911 1.7957 1.7952 1.7689 1.7079 1.6484 1.00 1.9772 1.9386 1.8994 1.8694 1.8292 1.7902 1.7600 1.7385 1.7263 1.7175 1.6976 1.6595 1.6242 1.20' 2.2407 2.1709 2.1206 2.0896 2.0428 2.0016 1.9682 1.9384 1.9129 1.8882 1.8329 1.7856 1.7498 1.50 2.7638 2.7373 2.6935 2.6521 2.5878 2.5086 2.4298 2.3520 2.2759 2.1999 2.0808 1.9734 1.9242 1.70 2.7057 2.7314 2.7264 2.7171 2.6894 2.6473 2.5974 2.5423 2.4849 2.4229 2.2828 2.1717 2.0855 2.00 2.3827 2.4646 2.5479 2.6206 2.6863 2.7508 2.8028 2.8386 2.8610 2.8701 2.8457 2.7616 2.6509 2.50 2.0405 2.1093 2.1742 2.2315 2.2980 2.3889 2.4748 2.5528 2.6231 2.6887 2.8085 2.9032 2.9470 3.00 1.7262 1.7715 1.8176 1.8586 1.8978 1.9322 1.9621 1.9896 2.0161 2.0419 2.0909 2.1502 2.2062 3.50 1.6972 1.7272 1.7584 1.7913 1.8229 1.8521 1.8785 1.9025 1.9251 1.9468 1.9881 2.0238 2.0640 4.00 1.6925 1.7181 1.7378 1.7585 1.7861 1.8200 1.8582 1.8951 1.9287 1.9597 2.0148 2.0589 2.0857 5.00 1.6051 1.6272 1.6504 1.6722.

1.6909 1.7065 1.7202 1.7331 1.7454 1.7634 1.7966 1.8251 1.8415 7.00 1.4460 1.4483 1.4505 1.4522 1.4529 1.4509 1.4503 1.4522 1.4563 1.4637 1.4902 1.5275 1562 10.00 1.5256 1.5205 1.5362 1.5523 1.5625 1.5672 1.5700 1.5728 1.5768 1.5825 1.5935 1.6107 1 68

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 154 of 349 Date: 08/27/03 Table 10,3b. A licaion Factor for Lower Profile M=7.0___

Per PGA PGA PGA PGA PGA PGA PGA PGA PGA PdA PGA PGA PGA (sec)

0.

2g 0

.3e 0.4g 03e 0.7g 0.8gy 0.9g 1.Og 1.2a I.4° 1.6g 0.01 1.5524 1.4049 1.2415 1.1406 1.0728 1.0003 0.9232 0.8447 0.7773 0.7276 0.6454 0.5818 0.5237 0.03 1.5964 1.4461 1.2741 1.1663 1.0961 1.0214 0.9420 0.8615 0.7922 0.7406 0.6557 0.5909 0.5318

  • 0.05 1.3640 T.1846 It.0324 0.9433-0:8849 0.8236 0.782 0.6920 0.63560.5933 0.5238 0;47S O

0.4247 0.07 1.2242 1.0658 0.9099 0.8063 0.7496 0.6944 0.6379 0.5808 0.5323 0.4953 0.4357 0.3922 0.3530 0.10 1.3233 1.0026 0.8165 0.7344 0.6790 0.6230 0.5661 0.5110 0.4638 0.4275 0.3690 0.3306 0.2954 0.12 1.5171 1.1164 0.9112 0.7566 0.6651 0.6032 0.5436 0.4870 0.4396 0.4036 0.3457 0.3061 0.2724 0.15 1.7719 1.2000 0.9885 0.8226 0.7069 0.6252 0.5516 0.4810 0.4252 0.3898 0.3343 0.2920 0.2591 0.17 1.8435 1.4092 1.1931 0.9787 0.7884 0.6519 0.5432 0.4805 0.4268 0.3849 0.3315 0.2930 0.2635 0.20 1.8216 1.4479 1.3053 1.1222 0.9490 0.8052 0.6849 0.6004 0.5338 0.4738 0.3768 0.3245 0.2815 0.25 2.2286 1.7065 1.4292 1.2712 1.1342 1.0033 0.8677 0.7548 0.6724 0.5956 0.4775 0.3989 0.3399 0.30 2.3626 2.0255 1.6983 1.4760 1.2885 1.1282 0.9977 0.8906 0.7989 0.7141 0.5963 0.5063 0.4350 0.35 2.3034 2.2749 2.1130 1.9177 1.6959 1.4724 1.2563 1.1167 0.9877 0.8790 0.7197 0.6123 0.5310

-0.4L1 1.9034 1;9156- -. 9012 1.8729 1.7928 1.6843 L,5494_

F;4023 1.2587 I.1}293 0.9309 0-.-7922

  • 0.6934 0.50 1.6908 1.6467 1.6082 1.5732 1.5512 1.5101 1.4490 1.3938 1.3459 1.2820 1.1369 1.0064 0.9003 0.60 2.0634 1.9563 1.7671 1.6356 1.5817 1.5170 1.4417 1.3726 1.3292 1.2747 11.1559 1.0466 0.9590 0.70 1.7307 1.7769 1.7626 1.7122 1.6682 1.6086 1.5615 1.5219 1.4763 1.4141 1.2715 1.1489 1.0538 0.80 1.6436 1.6608 1.6736 1.7014 1.7061 1.6785 1.6266 1.5926 1.5600 1.5097 1.3750 1.2479 1.1437 0.90 1.6772 1.6346 1.6139 1.6169 1.6111 1.5926 1.5688 1.5526 1.5421 1.5292 1.4696 1.3911 1.3081 1.00 1.7517 1.6908 1.6721 1.6628 1.6657 1.6580 1.6414 1.6275 1.6147 1.5997 1.5417 1.4577 1.3601 120 2.1262 1.9931 1.9053 1.8166 1.7567 1.7153 1.6853 1.6755 1.6637 1.6530 1.6180 1.5666 1.4967 1.50 2.3961 2.3315 2.2634 2.1954 2.1216 2.0456 1.9819 1.9350 1.8952 1.8558 1.7746 1.7030 1.6283 1.70 2.5699 2.6109 2.6021 2.5455 2.4460 2.3637 2.3079 2.2471 2.1955 2.1415 2.0585 1.9740 1.8792 2.00 2.3184 2.4116 2.4881 2.5412 2.5676 2.5710 2.5758 2.5696 2.5479 2.5129 2.4087 2.2809 2.1606 2.50 1.9042 1.9769 2.0518 2.1273 2.1945 2.2541 2.3095 2.3568 2.3938 2.4262 2.4814 2.4946 2.4618 3.00 1.7033 1.7446 1.7728 1.8048 1.8527 1.9019 1.9715 2.0293 2.0731 2.1188 2.2101 2.2867 2.3407 3.50 1.5940 1.6320 1.6619 1.6935 1.7279 1.7564 1.8050 _1.8471 1.8814 1.9111 1.9566 2.0017 2.0688 4.00 1.5184 1.5771 1.6251 1.6684 1.7049 1.7342 1.7558 1.7715 1.7827 1.7920 1.8055 1.8262 1.8494 5.00 1.3356 1.3721 1.4036 1.4288 1.4483 1.4641 I.4759 1.4846 1.4909 1.4995 1.5098 1.5168 1.5411 7.00 1.2752 1.2780 1.2895 1.2979 1.3038 1.3106 1.3217 1.3332 1.3406 1.3449 1.3423 1.3371 1.3582 10.00 1.3238 1.3354 1.3557 1.3752 1.3918 1.4055 1.4189 1.4340 1.4463 1.4578 1.4707 1 4768 1.4743

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 155 of 349 Date: 08/27/03.

Table 10-3 c. Amplification Factor for Lower Profile, M=7. 8 D

Per PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA (sec) 0.12 0.2g 0.32 0.4g 0.5g 0.6g 0.7 08g 0.9g lO 1.2e 1.4e 1.6g 0.01 1.4649 1.3085 1.2061 1.0903 0.9983 0.8995 0.7894 0.6946 0.6262 0.5680 0.4699 0.4098 0.3831 0.03 1.5063 1.3293 1.2214 1.1045 1.0104 0.9103 0,7988 0.7029 0.6333 0.5744 0.4751 0.4143 0.;874

-- 0.05 1.1144" 0.9391 0:8683' 0.7846 0.7162- 0.6446 0.5653 0.49Th' 0.4474 0.4055-G.33S1 0.2920

01730.

0.07 1.0280 0.8113 0.7323 0.6597 0.6024 0.5417 0.4747 0.4174 0.3747 0.3394 0.2801 0.2438 0.2279 0.10 1.2705 0.9260 0.7705 0.6459 0.5623 0.4975 0.4316 0.3767 0.3366 0.3032 0.2480 0.2147 0.2007 0.12 1.4259 0.9867 0.7915 0.6661 0.5750 0.4927 0.4228 0.3674 0.3233 0.2901 0.2390 0.2060 0.1928 0.15 1.5899 1.1728 0.8676 0.6678 0.5653 0.4815 0.4072 0.3565 0.3176 0.2847 0.2324 0.1957

0.

O820 0.17 1.7882 1.2756 0.9451 0.7492 0.6315 0.5403 0.4556 0.3817 0.3310 0.2951 0.2417 0.2053 0.1857 0.20 1.8847 1.4404 1.1830 0.9889 0.8358 0.7024 0.5892 0.5020 0.4341 0.3774 0.2873 0.2262 0.1927 0.25 1.9435 1.6089 1.3925 1.2171 1.0401 0.8986 0.7673 0.6597 0.5702 0.4974 0.3819 0.3051 0.2582 0.30 2.2532 1.9228 1.5510 1.2939 1.1329 0.9877 0.8522 0.7403 0.6507 0.5788 0.4624 0.3818 0.3247 0.35 2.2836 1.9788 1.7031 1.4945 1.3296 1.1587 0.9939 0.8662 0.7727 0.6906 0.5408 0.4390 0.3669 0.40 1.8486 - 1.9904 1.93 41-370 1.6535

-1.4449 1.2419.1.0884 0.9704 0.8647.

0.6640 0.5260 0404 4 0.50 1.6985 1.4837 1.4102 1.4120 1.4262 1.3960 1.3124 1.2155 I 1.1314 1.0544 0.8992 0.7705 0.6770 0.60 2.2111 1.9183 1.6439 1.4528 1.3652 1.2900 1.1914 1.0988 1.0291 0.9756 0.8919 0Q8392 0.8112 0.70 1.8280 1.9047 1.8602 1.7768 1.6616 1.5082 1.3138 1.1527 1.0332 0.9385 0.8013 0.7365 0.7233 0.80 1.6354 1.6806 1.6781 1.6806 1.6687 1.6093 1.4702 1.3022 1.1612 1.0594 0.8841 0.7677 0.6978 0.90 1.5449

.J.5110 1.5233 1.5688 1.5862 1.5590 1.4712 1.3577 1.2481 1.1521 0.9963 0.8639 0.7842 1.00 1.5604 1.5320 1.5019 1.5140 1.5138 T.5024 1.4710 1.4i33 1.3657 1.2948 1.1076 0.9350 0.8228 1.20 2.0553 1.9280 1.8179 1.7312 1.6477 1.5567 1.4714 1.4170 1.3804 1.3442 1.2674 1.1783 1.1171 1.50 2.5332 2.4411 2.2897 2.1566 2.0457 1.9156 1.7666 1.6425 1.5428 1.4656 1.3313 1.2494 1.2045 1.70 2.6906 2.7303 2.6498 2.5215 2.3701 2.2183 2.0582 1.9085 1.7757 1.6679 1.4985 1.3853 1.3095 2.00 2.2814 2.3979 2.4561 2.5081 2.5365 2.5116 2.4317 2.3188 2.1885 2.0514 1.8454 1.7096 1.6171 2.50 1.8021 1.9463 2.0671 2.1601 2.2267 2.2953 2:3358 2.3452 2.3302 2.2989 2.1987 2.0919 2.0001 3.00 1.5626 1.6192 1.6787 1.7468 1.8130 1.8751 1.9271 1.9638 2.0142 2.0775 2.2074 2.2679 2.2623 3.50 1.7449 1.8216 1.8892 1.9581 2.0250 2.0893 2.1491 2.2022 2.2503 2.2903 2.3759 2.4727.2.5566 4.00 1.3841 1.4400 1.5126 1.5803 1.6391 1.6985 1.7548 1.8045 1.8475 1.8863 1.9565 2.0523 2.1440 5.00 1.3710 1.4112 1.4477 1.4800 1.5047 1.5246 1 5428 1.5832 1.6237 1.6587 1.7210 1.7747 1.8184 7.00 1.1557 1.1764 1.1988 1.2197 1.2373 1.2530 1.2657 1.2785 1 1.2980 1.3198 1.3633 1.4024 1.4355 10.00 1.2207 1.2533 1.2854 1.3071 1.3204 1.3298 1.3398 1.3512 1.3620 1.3717 1.3863 1.3967 1.4061

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 156 of 349 Date: 08/27/03 Table 10-4a. Amrlification Factor for Hiszher Profile. M=6.0 Per PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA (sec) 0.1 0.2g 0.3g 0.4g 0.5g 0.6

0.

0.8g 0.9g I.Og 1.2g 1.4g 1.6g 0.01 1.7674 1.6451 1.5553 1.5064 1.4744 1.4269 1.3609 1.2937 1.2312 1.1727 1.0778 I 1.0001 0.9234 0.03 2.0233 1.8699 1.7308 1.6684 1.6271 1.5709 1.4948 1.4181 1.3460 1.2793 1.1707 1.0850 1.0009 0.05 1.8849 1.409 1.5494 -1.469V1 1.4184 1.3624 A.:2881 1.2134 1.1429 L0826 0.9793

-0.9042 0.8322.

0.07 2.0195 1.7347 1.5003 1.3470 1.2822 1.2272 1.1549 1.0966 1.0344 0.9752 0.8785 0.7922 0.71-5.9 0.10 2.0986 1.9066 1.7077 1.5452 1.4137 1.2973 1.2069 1.1176 1.0250 0.9487 0.8395 0.7670 0.6981 0.12 2.2636 2.1650 1.9581 1.8286 1.7009 1.3760 1.4793 1.3826 1.2802 1.1895 1.0313

.0.9035

-0(8001

-0.15 2.1773 1.9823 1.8769 1.7745 1.6563 1.5207 1.3891 1.2957 1.2218 1.1546 1.0293.

0:929.

0.8503 0.17 2.9341 2.5581 2.2998 2.0508 1.8442 1.6837 1.5624 1.4624 1.3787 1.3189 1.2166 1.1121 1.0221 0.20 2.6021 2.4836 2.4434 2.4190 2.3290 2.1777 2.0285 1.8926 1.7709 1.6748 1.5287 1.4043 1.2960 0.25 2.1728 2.1911 2.2050 2.2261 2.2329 2.2045 2.1511 2.0869 2.0174 1.9495 1.8312 1.7166 1.6085 0.30 1.9011 1.7785 1.6988 1.6742 1.7022 1.7314 1.7458 1.7476 1.7361 1.7276 1.7130 1.6753 1.6303 0.35 2.3740 2.2212 2.0827.1.9719 1.8866 1.8164 1.7520 1.6861 1.6221 1.5684 1.4898 1.4495 1.4261 70`40 2.4067 1 2;4126-2.36581 2 307 J-2.2430 2.1557 1.2;0559-1.9528 I 1.84890+/--L7446 1.57921 1,4616 1.3830 1.7106 0.50 1.8305 I 1.8754 1.8998 1 l.9533-1 2.0035 2.0330 1 2.0402 2.0305 I 2.0053 I 1.9710 1.8895 i 1.8003 0.60 1.6728 1.7013 1.7192 1.7378 1.7619 1.7766 1.7822 1.7852 1.7847 f.7826 1.7723 1.7580 1.7336 0.70 1.8738 1.8204 1.7696 1.7213 1.7093 1.6991 1.6810 1.6733 1.6680 1.6623 1.6490 1.6398 1.6298 0.80 2.2278 2.1628 2.1162 2.0909 2.0784 2.0602 2.0350 2.0061 1.9737 1.9435 1.8862 1.8355 1.7900 0.90 2.5844 2.5429 2.4848 2A331 2A169 2.4019 2.3816 2.3570 2.3249 2.2898 2.2176 2.1499 2.0851 1.00 2.5357 2.5473 2.5405 2.5238 2.5052 2.4752 2.4326 2.3944 2.3563 2.3330 2.2850 2.2382 2.1900 1.20 2.5835 2.6372 2.6788 2.7266 2.7718 2.8064 2.8262 2.8320 2.8252 2.8089 2.7635 2.7053 2.6415 1.50 2.0752 2.1320 2.1898 2.2382 2.2772 2.3141 2.3522 2.3996 2.4442 2.4847 2.5540 2.6092 2.6504 1.70 1.9727 2.0143 2.0526 2.0864 2.1227 2.1558 2.1938 2.2319 2.2687 2.3028 2.3640 2.4204 2.4808 2.00 1.7971 1.8380 1.8773 1.9149 1.9495 1.9811 2.0089 2.0336 2.0570 2.0881 2.1402 2.1812 2.2131 2.50 1.5603 1.5853 1.6113 1.6390 1.6655 1.6927 1.7183 1.7416 1.7638 1.7841 1.8186 1.8465 1.8802 3.00 1.4399 1.4589 1.4810 1.5024 1.5209 1.5381 1.5535 1.5671 1.5802 1.5922 1.6136 1.6311 1.6450 3.50 1.4070 1.4173 1.4251 1.4346 1.4434 1.A560 1.4675 1.4842 1.5006 1.5158 1.5428 1.5714 1.5984 4.00 1.4808 1.4881 1.4941 1.4999 1.5058 1.5123 1.5186 1.5243 1.5288 1.5325 1.5381 1.5475 1.5706 5.00 1.4892 1.5030 1.5147 1.5251 1.5348 1.5440 1.5524 1.5598 1.5659 1.5710 1.5794 1.5857 1.5896 7.00 1.3881 1.3938 1.3942 1.3934 1.3929 1.3919 1.3906 1.3888 1.3870 1.3849 1.3928 1.4024 1.4098 10-00 1.4256 1.4377 1IA449 1 1.4485 1.4536 1.4571 1.4605 1.4637 1.4669 1.4704 1.4786

[.4858 1.49070

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 157 of 349 Date: 08/27/03 Table 10-4b. Amplifcation Factor for Higher Profile, M=7.0 Per PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA (sec) 0.1l 0.22 0.3a 0.4g 0M5 0.6g 0

0.8e 0.9g 1.04 1.6a 0.01 1.8493 1.7348 1.5964 1.4577 1.3326 1.2301 1.1627 1.1108 1.0641 1.0176 0.9388 0.8730 0.8123 0.03 1.9270 1.8028 1.6571 1.5069 1.3734 1.2660 1.1953 1.1413 1.0929 1.0446 0.9626 0.8928 0.8304

  • 0.05. 1.7008 1.5342 1.3954 1.2658

.1.1477 1.0527 0.9852.0.9361 0.89;1.

.0$536 0.7831 0-7225 0.6710 0.07 1.7484 1.4557 1.2679 1.1306 1.0208 0.9357 0.8584 0.8072 0.7649 0.7298 0.6698 0.6206 0.5735 0.10 2.1173 1.6355 1.3471 1.1873 1.0883 0.9881 0.8996 0.8216 0.7541 0.7007 0.6202 0.5604 0.5065 0.12 2.1207 1.9185 1.6482 1.4301 1.2747 1.1581 1.0473 0.9473 0.8598 0.7802 0.6641 0.5963 0.5331 0.15 2.0388 1.8216 1.7056 1.5340 -1.4039 1.2866 1.1780 1.0755 0.9818 0.8962 0.7508 0.6370 0.5507 0.17 2.6295 2.1466 1.7496 1.5516 1.3913 1.2687 1.1722 1.0904 1.0108 0.9541 0.8418 0.7308 0.6331 0.20 2.6089 2.4705 2.2315 1.9680 1.7304 1.5273 1.3692 1.2251 1.1014 1.0080 0.8577 0.7505 0.6497 0.25 2.0974 2.1782 2.1748 2.1116 2.0495 1.9619 1.8563 1.7446 1.6362 1.5258 1.3145 1.1374 0.9722 0.30 1.8368 1.6966 1.6394 1.5731 1.5220 1.4872 1.4531 1.4395 1.4312 1.4168 1.3474 1.2512 1.1339 0.35 2.1424 1.9212 1.7727 1.6045 1.4552 1.3599 1.3035 1.2631 1.2326 1.2056 1.1651 1.1576 1.1423

.0.40 2.1392 2.0435..1.9218 1.7670.1.-52-3e

.1.5738 1.5050 1.4458 1.3949 iL3452 1.2596 1.1789 1.0932 0.50 1.7181

.1.7339 1.7395 1.7206 1.6940 1.6718 1.6386 1.5986 1.5557 1.5067 1.4083 1.3224 1.2362 0.60 1'6690 1.6829 1.6961 1.6908 1.6670 1.6381 1.6069 1.5787 1.5582 1.5373 1.5011 1.4597 1.3934 0.70 1.7170 1.6993 1.6982 1.6889 1.6639 1.6349 1.6059 1.5792 1.5546 1.5311 1.4929 1.4568 1.4127 0.80 1.9751 1.8791 1.8084 1.7456 1.7021 1.6579 1.6227 1.5962 1.5714

.1.5472 1.5063 1.4680 1.4267 0.90 2.3901 2.3257 2.2695 2.2072 2.1390 2.0754 2.0189 1.9688 1.9231 1.8787 1.7919 1.7077 1.6308 1.00 2.4737 2.4367 2.4059 2.3659 2.3116 2.2533 2.1964 2.1426 2.0916 2.0412 1.9420 1.8429 1.7552 1.20 2.5069 2.6168 2.6865 2.7266 2.7340 2.7138 2.6767 2.6291 2.5813 2.5258 2.4342 2.3199 2.1888 1.50 1.8625 1.9732 2.0627 2.1422 2.2112 2.2646 2.3041 2.3307 2.3484 2.3585 2.3648 2.3523 2.3230 1.70 1.7759 1;8681 1.9415 2.0058 2.0622 2.1094 2.1498 2.1834 2.2161 2.2554 2.3373 2.4229 2.4876 2.00 1.6578 1.7089 1.7518 1.8026 1.8718 1.9324 1.9853 2.0307 2.0696 2.1054 2.1654 2.2166 2.2660 2.50 1.4780 1.5240 1.5616 1.5933 1.6209 1.6450 1.6667 1.6850 1.7006 1.7153 1.7416 1.7714 1.8297 3.00 1.3903 1.4306 1.4648 1.4949 1.5213 1.5433 1.5618 1.5772 1.5898 1.6008 1.6159 1.6295 1.6543 3.50 1.2582 1.2765 1.2893 1.3070 1.3422 1.3745 1.4034 1.4288 1.4509 1.4714 1.5056 1.5349 1.5611 4.00 1.2629 1.2772 1.2936 1.3108 1.3274 1.3426 1.3571 1.3705 1.3827 1.3944 1.4321 11.4656 1.4960 5.00 1.1142 1.1412 1.1619 1.1836 1.2030 1.2199 1.2356 1.2503 1.2644 1.2784 1.3034 1.3266 1.3483 7.00 1.1707 1.1826 1.1931 1.2006 1.2077 1.2122 1.2148 1.2161 1.2173 1.2224 1.2312 1.2384 1.2442 10.00 1.2823 1.2968 1.3085 1.3192 1.3249 1.3263 1.3259 1.3243 1.3220 1.3194 1.3136 1.3081 1.3037

Calc Number: GEO.HB[P.03.02 Rev Number: 0 Sheet Number: 158 of 349 Date: 08/27/03 Table 10-4c. Amplification Factor for Higher Profile, M=7.8 Per PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA PGA (sec)

O.

0.2g 0.3g 0.4g 0U5 0.7g O.Sg 0.92

.02 1.22 1.4g 1.6g 0.01 1.7490 1.4413 1.3777 1.3489 1.2820 1.2101 1.1409 1.0772 1.0275 0.9791 0-8882 0.8458 0.8129 0.03 1.8159 1.4927 1.4136 1.3819 1.3114 1.2359 1.1634 1.0984 1.0452 0.9951 0.9007 (0.856()

0.8225 0.05 1L6229 - 1.2929 1.0422..1.0034 0.9507.048939 0.8383 0.7909 :0.7462 0.7093 0.6406 0.6052 0.5812 0.07 1.6674 1.3527 1.0882 0.9458 0.8737 0.8063 0.7552 0.7079 0.6562 0.6091 0.5431 0.5083 0.4871 0.10 2.0112 1.5369 1.2742 1.1370 1.0132 0.9037 0.8094 0.7366 0.6772 0.6264 0.5409 0.4826 0.4443 0.12 1.9041 1.6258 1.3971 1.2062 1.0513 0.9484 0.8688 0.7972 0.7339 0.6745 0.5700 0.4954 0.4357 0.15 1.9452 1.7402 1.4950 1.3260 1.1897 1.0577 0.9714 0.9015 0.8223 0.7438 0.5972 0.4973 0.4348 0.17 2.3610 1.8655 1.5758 1.3917 1.2600 1.1933 1.1061 1.0016 0.9009 0.8093 0.6589 0.5537 0.4874 0.20 2.4255 2.2183 1.9610 1.7512 1.5185 1.3298 1.1715 1.0581 0.9854 0.9243 0.8117 0.7052 0.6021 0.25 2.0977 2.1523 2.0977 1.9832 1.8632 1.7677 1.6536 1.5149 1.3711 1.2259 1.0080 0.8730 0.7605 0.30 1.7340 1.6700 1.6416 1.6374 1.6314 1.6041 1.5493 1.4948 1.4208 1.3335 1.1647 1.0413 0.9241 0.35 1.9234 1.7242 1.6192 1.5354 1.4758 1.4336 1.3834 1.3190 1.2606 1.2051 1.0999 1.0133 0.9264 0.40 2.;2869.~.2.1325 1.9408, 1,7429 1.5537 1.395.1 1.2862 1.2059 1.1543 1.1118 J.D8. 1.0168 0.9980 0.50 1.4887 1.5769 1.6532 1.6890 1.6795 1.6323 1.5658 1.4659 1.3649 1.2684 1.0969 1.0021 0.9482 0.60 1.6311 1.6476 I 1.6520 1.6319 1.6132 1.6027 1.5944 1.5895 1 1.5893 1.5710 I 1.4765 1.3614 1.2580 0.70 1.8138 1.7667

.1.7441 1.7084 1.6669 1.6298 1.5983 1.5709 1.5462 1.5183 1.4759 1.4496 1.4198 0.80 2.1151 1.9810 1.8794 1.7744 1.6777 1.6127 1.5784 1.5667 1.5533 1.5330 1.4779 1.4268 1.3816 0.90 2.2549 2.1889 2.1295 2.0586 1.9753 1.8937 1.8172 1.7457 1.6824 1.6213 1.5107 1.4240 1.3611 1.00 2.6553 2.5780 2.4839 2.3567 2.2204 2.1167 2.0238 1.9365 1.8532 1.7816 1.6417 1.5433 1.4676 1.20 2.5624 2.6487 2.7004 2.7108 2.6799 2.6441 2.5976 2.5353 2.4641 23761 2.1785 2.0263 1.9031 1.50 1.9106 2.0174 2.1165 2.2107 2.2981 2.3902 2.4718 2.5340 2.5734 2.5900 2.5558 2.4834 2.3855 1.70 1.8396 1.9189 1.9978 2.0737 2.1544 2.2308 2.3037 2.3853 2.4681 2.5393 2.6350 2.6868 2.6807 2.00 1.5357 1.6021 1.6624 1.7257 1.7893 1.8502 1.9107 1.9726 2.0318 2.0932 2.2046 2.2807 2.3355 2.50 1.3118 1.3522 1.3886 1.4247 1.4597 1.4929 1.5247 1.5611 1.5980 1.6357 1.7235 1.7944 1.8684 3.00 1.2627 1.2763 1.2923 1.3145 1.3384 1.3634 1.3912 1.4212 1.4489 1.4735 1.5116 1.5449 1.5792 3.50 1.3535 1.3852 1.4160 1.4504 1.4860 1.5189 1.5483 1.5754 1.6000 1.6245 1.6806 1.7296 1.7768 4.00 1.1714 1.1834 1.1961 1.2087 1.2207 1.2334 1.2475 1.2638 '1.2837 1.3052 1.3437 1.3790 1.4266-5.00 1.1760 1.1893 1.2037 1.2181 1.2338 1.2503 1.2678 1.2864 1.3044 1.3208 1.3493 1.3741 1.3979 7.00 1.0829 1.0908 1.1003 1.1104 1.1177 1.1226 1.1260 1.1306 1.1355 1.1400 1.1498 1.1610 1.1736 10.00 1.1765 1.1821 1.1843 1.1848 1.1836 1.1821 1.1811 1.1817 1.1848 1.1891 1.2033 1.2210 1.2414

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 159 of 349 Date: 08/27/03 Table 10-5. Average Horizontal Rock Spectral Shape Based on Northridge Strong Motion Recordings.

Period (sec)

Average r-Spectral Shape (Sa/pga) 0.010 1ooo 0.020 1.000 0.030 1.016 0.050 1.095 0.075 1.225

-0.100 1.384 0.150 1.690 0.200 1.911 0.300 2.368 0.500 1.980 0.750 2.049 1.000 1.682 1.500 1.036 2.000 0.765 3.000 0.451 4.000 0.208 i r

... 4

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 160 of 349 Date: 08/27/03

.11. LIMITATIONS After applying the amplification factors, the response spectral shape needs to be checked for the constraint that the shape is not less than the empirical shape given in Table 8-5.

12. IMPACT EVALUATION This calculation provides the site amplification factors needed for the PSHA study at HBIP (Calculation GEO.HBIP.03.04). It is consistent with the previous site amplification factors used in the deterministic evaluation of the ground motion at HBIP (GEO.HBIO.02.04).
13. REFERENCES Abrahamson, N. A., and W. J. Silva (1997) "Empirical Response Spectral Attenuation Relations for Shallow Crustal Earthquakes", Seismological Research Letters, Vol. 68, No. 1, pp.94-127.

GEO.BIP.02.06, Site Amplification Factors for HBIP, prepared by PG&E Geosciences Department, November 6, 2002.

GEO.DCPP.01.32, Verification of Computer Program SPCTLR.EXE, prepared by PG&E Geosciences Department for DCPP, ISFSI, August, 2002

Calc Number: GEO.HBIP.03.02 Rev Number: 0 Sheet Number: 161 of 349 Date: 08/27/03

14. ENCLOSURES AND ATTACHMENTS Three spreadsheets used to compute the amplification factors are given on the enclosed CD ROM.

Each spreadsheet file contains three worksheets; one for each magnitude (M6, M7, M7. 8)

Within each worksheet, there art the rock motion spectral shapes, the soil spectra, the amplification for..

each case (each time history), the average amplification (averaged over the three time histories), and the average rock spectrum (averaged over the three time histories).

File Name Contents ampFactor medProfile.xls amplification factors for the median soil profile ampFactor lowProfile.xls amplification factors for the lower bound soil profile ampFactor highProfile.xls amplification factors for the upper bound soil profile I

I -

The CD ROM also contains the all of the files used in the SHAKE96 calculations. A complete listing of these files is given in Appendix A.

GEO.HBIP.03.02, Rev 0 Page: 162 of 349 9/29/03 Pages 162 through 349 are attachments of computer input and output data, and are not printed. They exist in electronic format on a CD in records retention system.