S4BARTLETT ENGINEERING CALCULATION Calculation Number: ENG-HB-004 Revision Number:
0 Calculation
Title:
Guideline Levels Humboldt Bay Buildinc Surface Derived Concentration Preparer:
Reviewer:
Approval:
Date 2/ 24'1i-.
Date 2/t2IJ'*
A*e hee'si-en t Engineerin*/Corporate Project Manager Bartlett.
60 Industrial Park Road Plymouth, MA 02360
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 1.0 PURPOSE The purpose of this calculation is to develop building surface derived concentration guideline levels (DCGLs) to support final status surveys at the Humboldt Bay site. This calculation is part of the scope of work defined in Contract No. GTO12 3500895165.
2.0 APPLICABILITY This calculation addresses only the development of building surface DCGLs for Humboldt Bay.
3.0 REFERENCES
3.1 Bartlett Engineering Procedure ENG-AP-02, Verification of Software Operability 3.2 User's Manual for RESRAD-Build Version 3.0, June 2003 (ANL/EAD/03-1) 3.3 Bartlett Engineering Calculation ENG-HB-002, RESRAD-Build Input Parameter Sensitivity Analysis - Humboldt Bay 3.4 NUREG/CR-5512, Residual Radioactive Contamination from Decommissioning
" Volume 1: Technical Basis for Translating Contamination Levels to Annual Total Effective Dose Equivalent, Oct. 1992 (PNL-7994)
" Volume 3: Parameter Analysis, Draft Report for Comment, Oct. 1999 (SAND99-2148) 3.5 NUREG/CR-6697, Development of Probabilistic RESRAD 6.0 and RESRAD-Build 3.0 Computer Codes, Nov. 2000 (ANL/EAD/TM-98) 3.6 NUREG/CR-6755, Technical Basis for Calculating Radiation Doses for the Building Occupancy Scenario Using the Probabilistic RESRAD-Build 3.0 Code, Feb. 2002 (ANL/EAD/TM/02-1) 3.7 NUREG-1 727, NMSS Decommissioning Standard Review Plan, Sept. 2000 4.0 METHOD OF CALCULATION The operability of the RESRAD-Build code was verified on each computer used for code executions in accordance with Engineering procedure ENG-AP-02, Verification of Software Operability [ref. 3.1]. The RESRAD-Build user's manual [ref. 3.2] provided guidance for code operation.
Version 3.5 of the RESRAD-Build code was used to calculate building surface DCGL values.
The RESRAD-Build computer code is a pathway analysis model designed to evaluate the potential radiological dose incurred by an individual who works in a building contaminated with radioactive material.
The exposure scenario modeled in this calculation is the building renovation scenario. The exposure pathways considered are (i) direct external exposure from the source (i.e., radioactive material deposited on the floor, walls, and ceiling), (ii) external exposure from deposited material, (iii) external exposure due to air submersion, (iv) exposure
(*BARTLETT Page 2
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 due to inhalation of airborne radioactive material, (v) ingestion of radioactive material directly from the sources and material deposited on the surfaces.
The RESRAD-Build code requires input for numerous parameters in order to calculate the dose via various exposure pathways to a hypothetical individual working in a building contaminated with radioactive material. Bartlett Engineering Calculation ENG-HB-002 [ref. 3.3] documents the selection process and sensitivity analyses performed for these numerous parameters; this calculation incorporates those results.
The sensitivity analyses performed for the building renovation scenario input parameters identified four sensitive input parameters (i.e., parameters whose values greatly influence the calculated dose) for that scenario: deposition velocity, resuspension rate, time for source removal, and room air exchange rate.
All other input parameters for the building renovation scenario were non-sensitive.
In order to support the development of building surface DCGLs, Bartlett Engineering Calculation ENG-HB-002 [ref. 3.3] provided recommendations for reasonably conservative values for the sensitive parameters: 2 5th and 7 5th percentiles of the input parameter distributions. Use of 2 5th and 7 5 th percentiles values provides assurance that the DCGL calculations take into account the uncertainties associated with these sensitive input parameters. The input values used in this calculation are consistent with both the selected scenario and the results of the sensitivity analyses.
RESRAD-Build version 3.5 code runs were performed for each of the radionuclides-of-concern (ROCs) for the Humboldt Bay site. Because each radionuclide was entered at a concentration of 1.0 pCi/m 2 and RESRAD-Build code calculates the annual dose associated with that contamination level, the RESRAD-Build results (i.e., mrem/y per 1.0 pCi/m 2) were used as a dose conversion factor (DCF) to obtain building surface DCGL values that corresponded to the targeted acceptance criterion, 25 mrem/y.
This was accomplished using the following conversions:
The targeted acceptance criterion, 25 mrem/y, divided by the RESRAD-Build DCF, mrem/y per pCi/m 2 = the DCGL in units of pCi/m 2 corresponding to 25 mrem/y.
The next step was to convert the 25-mrem/y DCGL values (in units of pCi/m 2) to practical values (in units of dpm/1 00cm 2) that would support decommissioning and final status survey activities:
25-mrem/y DCGL (in pCi/m 2) - (2.22 dpm/1 pCi). (M/1 00cm)2. 100 = 25-mrem/y DCGL in units of dpm/1 00cm2 5.0 ASSUMPTIONS AND INPUT 5.1 Assumptions Building Occupancy Scenario description: The RESRAD-Build code v3.5 was used to model (through use of input parameter values) the building occupancy scenario defined in NUREG/CR-5512, volume 1 [ref. 3.5].
The following exposure pathways are assumed active: (i) direct external exposure from the source (i.e., residual radioactive material on the floor, walls, and ceiling), (ii) external exposure from deposited airborne material, (iii) external exposure due to air submersion, (iv) exposure due to inhalation of airborne radioactive material, (v) ingestion of radioactive material directly from the sources and material deposited on the surfaces.
B ARTLETT Page 3
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0
" Twenty-two ROCs are identified for the Humboldt Bay: Am-241, C-14, Cm243/244/245/246, Co-60, Cs-137, Eu-152, Eu-154, H-3, 1-129, Nb-94, Ni-59, Ni-63, Np-237, Pu-238/239/240/241, Sr-90, and Tc-99.
The hypothetical individual occupies a room and performs work-related activities inside the building for a full occupational year (assumed equivalent to 97.5 twenty-four hours days [ref.3.5]).
Conservative breathing rate equal to 45.6 m3/d, a rate appropriate for moderate to heavy activity [ref. 3.6].
" The dimensions assumed for the General Office Building (selected as a representative room for the Humboldt Bay site) are shown in Figure 1.
5.2 Input 0 Table 1 summarizes the classification, prioritization, values and their bases for all input parameters.
Values from NUREG/CR-5512, volume 3 [ref. 3.5], NUEG/CR-6697 [ref. 3.6],
NUREG/CR-6755 [ref. 3.7], or NUREG-1727 [ref. 3.8] were assigned for the following scenario-defined parameters:
o Exposure duration: 365.25 d o
Indoor fraction: 0.267 (= 97.5 work d/y divided by 365.25 d/y) o Breathing rate: 45.6 m3/d (= 24h x 1.9 m3/h, a rate appropriate for moderate to heavy activity [ref. 3.6]).
o Receptor location (center of room): 4.24m, 2.82m,1.Om o
Indirect ingestion rate: 1.1 E-04 m2/h o
Air fraction: 0.07 for all nuclides except H-3; 1.0 for H-3 o
Removable fraction: 0.1 0 Site-specific information (i.e., room dimensions) was used as the basis in calculations (see section 6.0) of values for the following parameters:
o Room area o
Room height o
Receptor location o
Location of center of source o
Source length o
Source area 25h or 7 5th percentile values from Bartlett Engineering Calculation ENG-HB-002
[ref. 3.3] were used as input for the sensitive parameters: deposition velocity, resuspension rate, time for source removal, and room air exchange rate. Table 1 shows these values.
MMBARTLETT Page 4
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Table 1: Percentile values for sensitive input parameters (data taken from Table 5 in Reference. 3.3)
Percentile Value Parametera 25th 50th 75th UD 1.51790E-05 8.52364E-05 4.78217E-04 DKSUS 6.70403E-10 1.79444E-08 4.87543E-07 RFO(1) 1.82493E+04 3.30569E+04 5.26952E+04 RFO(2) 1.82301 E+04 3.32029E+04 5.27188E+04 RFO(3) 1.81302E+04 3.30489E+04 5.27756E+04 RFO(4) 1.82071 E+04 3.3041 OE+04 5.27269E+04 RFO(5) 1.80948E+04 3.31085E+04 5.27132E+04 RFO(6) 1.82466E+04 3.30500E+04 5.26222E+04 LAMBDAT 8.35789E-01 1.51522E+00 2.72646E+00 a RFO(#) = source removal time (for source number), UD = deposition velocity, DKSUS = resuspension rate, and LAMBDAT = room air exchange rate.
Note: The parameters, deposition velocity (UD) and the resuspension rate (DKSUS), were not identified as sensitive for all sources of Co-60, Eu-152, and Eu-154 in the sensitivity analysis (see Table 4 in reference 3.3).
The 7 5 th percentile values were used as conservative input for all Co-60, Eu-1 52, and Eu-154 sources because only RESRAD-Build accepts and applies a single input value for these parameters to all sources.
6.0 CALCULATIONS AND RESULTS 6.1 Room dimensions: The dimensions of a representative room are shown in Figure 1.
Table 2 shows the unit conversion for the room dimensions and the area associated with each source (i.e., floor, walls, and ceiling).
6.2 Direct ingestion rate (hW) is calculated from the indirect ingestion rate from NUREG/CR-6755 [ref. 3.7], 1.1 E-04 m2/h, and the total source area, 118.36 M2, as follows:
(1.1 E-04 m2/h)/(118.03 M2) = 9.32E-07 hW 6.3 Location of the center of source: The center of each source was determined based on the representative room dimensions. The locations were determined as the mid-point of the dimension values for the X, Y, and Z-axes.
Table 3 presents the locations for the center of the sources.
6.4 RESRAD-Build v3.4 results: Table 4 (pages 9 through 14) summarizes the input used in each RESRAD-Build code execution.
6.4.1 Each of the radionuclides listed in section 5.1 was evaluated using an initial concentration of 1.0 pCi/m 2 in separate code executions.
6.4.2 Several evaluation times (t) were used to identify the approximate time of maximum dose.
For all ROCs except Pu-241, the maximum dose occurred in the first time interval (0-1 year; see Ref. 3.3). For Pu-241, the SBA RT L ETT Page 5
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 maximum dose may occur at a later time.
Therefore, multiple time intervals were used for Pu-241 to assure that the maximum dose was used to develop the DCGL value. RESRAD-Build results at the various time intervals are summarized below in Table 5.
6.5 The maximum doses shown in bold font in Table 5 were used to as the radionuclide-specific conversion factor (CF) for developing the DCGL values, which are presented in Table 6.
6.5.1 Column 2 in Table 6 presents the annual dose associated with a concentration of 1.0 pCi/m 2 as calculated using the RESRAD-Build code.
These results were used as radionuclide-specific conversion factors (CF) with units of mrem/y per pCi/m 2.
For each radionuclide, DCGL values corresponding to the acceptance criterion, 25 mrem/y (designated as DCGL25), were calculated as follows:
(15 mrem/y) divided by the radionuclide-specific CF = DCGL25 (pCi/m 2)
The resulting DCGL15 values are shown in column 3 of Table 6.
The following hand calculations verify the operation of the spreadsheet:
H-3: (25 mrem/y)/( 2.98E-09mrem/y per pCi/m2)= 8.39E+09 pCi/m2 Cs1 37: (25 mrem/y)/(1.15E-05 mrem/y per pCi/m2)= 2.10E+06 pCi/m 2 6.5.2 Column 3 of Table 6 presents the conversions of the DCGL25 values to practical values with units of dpm/1OOcm 2 (designated in Table 6 as DCGLw). These DCGLw values would support decommissioning and final status surveys at the Humboldt Bay site.
DCGL25, pCi/mi2. (2.22 dpm/1 pCi). (1 m2/1 0000cm 2) ° 100 = DCGLW, dpm/1 00cm 2 The following hand calculations verify the operation of the spreadsheet:
Sr-90: (2.1 OE+06)(2.22)(1 /10000)(100) = 4.66E+04 dpm/1 00cm 2 Pu-239: (1.69E+05)(2.22)(1 /10000)(100) = 3.75E+03 dpm/1 00cm 2 6.6 For practical application, the DCGLw values were rounded down to 2 significant digits. Table 7 presents the rounded DCGLw values.
(OBARTLETT Page 6
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Figure 1: Dimensions of Humboldt Bay General Office Building Room M BARTLETT Page 7
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Table 2: Representative Room Dimensions (Based on dimensions provided in Figure 1)
Recorded Source Dimension No.
Description Mt m b m2 1
floor N/A 47.77 2
north wall 27.8 8.47 21.09 3
east wall 18.5 5.64 14.04 4
south wall 27.8 8.47 21.09 5
west wall 18.5 5.64 14.04 wall height 8.17 2.49 total source area:
118.03 a Recorded length and width dimensions for representative room (see Figure 1).
b Feet to meter conversion factor: lft = 0.3048m.
Table 3: Location of Center of Sources Source Source Location of Center of Source (m)
No.
Description X-axis Y-axis Z-axis 1
floor 4.24 2.82 0.00 2
north wall 4.24 0.00 1.25 3
east wall 0.00 2.82 1.25 4
south wall 4.24 5.64 1.25 5
west wall 8.47 2.82 1.25 6
ceiling 4.24 2.82 2.49
/&)BARTLETT Page 8
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Table 4: RESRAD-Build Innut Parameter Values for DCGLs Parameter Type' Nuclide Treatmentb Value/Distribution Value Reference Source Exposure Duration (d)
B All D
365 NUREG/CR-5512, Vol.3,section 5.2.1 Indoor Fraction B
All D
0.267 NUREG/CR-5512, Vol.3,section 5.2.2.9 1,5 Use of ly provides doses at t=0y and Evaluation Time (y)
P All D
(1, 5, 10, 25, 50, t=ly; multiple input applied to verify 100 for Pu-241) time of peak dose Number of Rooms P
All D
1 NUREG/CR-5512 Am-241, Cm-243, Cm-244, Cm-245, Cm-246, Np-D 1.5179E-05 2 5th percentile value 237, Pu-238, Pu-239, Pu-240, and Pu-241 Deposition Velocity (m/s)
P C-14, Co-60, Cs-1 37, Eu-1 52, Eu-1 54, H-3, 1-129, D
4.78217E-04 Nb-94, Ni-59, Ni-63, Sr-90, and Tc-99 O
4.78217E-04 75___
percentilevalue Am-241, Cm-243, Cm-244, Np-237, Pu-238, Pu-5 0th 239, Pu-240, and Pu-241 D
1.79444E-08 percentile value Resuspension Rate (s-')
C-14, Cm-245, Cm-246, Co-60, Cs-137, Eu-152, Eu-1 54, H-3, 1-129, Nb-94, Ni-59, Ni-63, Sr-90, D
6.70403E-10 2 5( percentile value and Tc-99 Air Exchange Rate for Room (hW)
P All D
8.35789E-01 2 5th percentile value Room Area (M)
P All D
47.77 Humboldt Bay-specific data' (General Office Building)
Room Height (m)
P All D
2.49 Humboldt Bay-specific data (General Office Building)
Time Fraction B
All D
1 NUREG/CR-5512 Conservative inhalation rate for moderate to heavy activities -
Inhalation Rate (m3/d)
M All D
45.6 NUREG/CR-6697, Attachment C, section 5.1; NUREG/CR-5512, vol. 3, section 5.3.4 Indirect Ingestion Rate (m2/h)
B All D
0.0001 NUREG/CR6755 Receptor Location B
All D
4.24, 2.82,1.0 NUREG/CR-5512; site-specific room dimensions (General Office Building)
Shielding Thickness (cm)
P All D
0 Site-specific model-no shielding assumed RESRAD-Build default value for Shielding Density (g/cm3)
P All D
2.4 concrete - not used in DCGL calculations Default input - not used in DCGL Shielding Material P
All D
concrete calculatins calculations Number of Sources P
All 6Modeling for representative room (includes floor, 4 walls, and ceiling)
(0BARTLETT Page 9
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Table 4: RESRAD-Build Inhut Parameter Values for DCGLs Parameter Type' Nuclide Treatmentb Value/Distribution Value Reference Source External Dose Conversion Factor, (mrem/y M
All D
RESRAD-Build FGR12 per pCi/cm
- 2) library Air Submersion Dose Conversion Factor, RESRAD-Build FGR12 (mrem/y per pCi/m 3)
M All D
library Inhalation Dose Conversion Factor, M
All D
RESRAD-Build FGRi 1 (mrem/pCi) library Ingestionl Dose Conversion Factor, M
All D
RESRAD-Build FGR1 1 (mrem/pCi) library Source 1: Floor Type P
All area NUREG/CR-5512 Direction P
All Z
NUREG/CR-5512 site-specific data - center of floor Location of Center of Source: x,yz (m)
P All D
4.24, 2.82, 0.0 based on dimensions for General Office Building room site-specific data based on Source length X-axis (m)
P All D
8.47 dimensions for General Office Building room site-specific data based on Source length Y-axis (m)
P All D
5.64 dimensions for General Office Building room Area (M
- 2)
P All D
Source length inputs used H-3 1.0 Air Fraction B
All D
0.0 NUREG/CR-6697, Att. C Section 8.6 All others 0.07 Direct Ingestion (Wh)
B All D
9.32E-7 NUREG/CR6755, A.3.3 Removable Fraction P
All D
0.1 NUREG-1727, Table C.7. 1; NUREG/CR-6755, section 3.5 Time for Source Removal (d)
P C-1 4, Co-60, Cs-1 37, Eu-1 52, Eu-1 54,1-129, and D
52695.2 75'h percentile value Nb-94 Sr-90 and Tc-99 D
33056.9 501h percentile value Am-241, Cm-243, Cm-244, Cm-245, Cm-246, H-D 18249.3 2 5 Th percentiie value 3, Ni-59, Ni-63, Np-237, Pu-238, Pu-239, Pu-240, and Pu-241 Radionuclide Concentration (pCi/m
- 2)
P All D
1.0 Source 2: North Wall Type P
3 Area NUREG/CR-5512
(,
BARTLETT Page 10
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Table 4: RESRAD-Build Input Parameter Values for DCGLs Parameter Type' Nuclide Treatmentb Value/Distribution Value Reference Source Direction P
3 X
NUREG/CR-5512 site-specific data - center of floor Location of Center of Source: x,y,z (m)
P 3
D 4.24, 0.0, 1.25 based on dimensions for General Office Building room site-specific data based on Source length Y-axis (m)
P 2
D 8.47 dimensions for General Office Building room site-specific data based on Source length Z-axis (m)
P 2
D 2.49 dimensions for General Office Building room Area (M2)
P 2
D Source length inputs used Air Fraction B
All others D
1.0 NUREG/CR-6697, Alt. C Section 8.6 Direct Ingestion (hW)
B 2
D 9.32E-7 NUREG/CR6755,-A.3.3 Removable Fraction P
1 D
0.1 NUREG-1727, Table C.7.1; NUREG/CR-6755, section 3.5 Time for Source Removal (d)
P C-14, Co-60, Cs-1 37, Eu-1 52, Eu-1 54, and 1-129 D
52718.8 7 5th percentile value Nb-94, Sr-90, and Tc-99 D
33202.9 5 0 th percentile value Am-241, Cm-243, Cm-244, Cm-245, Cm-246, H-3, Ni-59, Ni-63, Np-237, Pu-238, Pu-239, Pu-240, D
18230.1 25Th percentile value and Pu-241 Radionuclide Concentration (pCi/m2)
P 2
D 1.0 Source 3: East Wall Type P
3 Area NUREG/CR-5512 Direction P
3 Y
NUREG/CR-5512 site-specific data - center of floor Location of Center of Source: x,y,z (m)
P 3
D 0.00, 2.82, 1.25 based on dimensions for General Office Building room site-specific data based on Source length X-axis (m)
P 2
D 5.64 dimensions for General Office Building room site-specific data based on Source length Z-axis (m)
P 2
D 2.49 dimensions for General Office Building room Area (M
- 2)
P 2
D Source length inputs used W;BARTLETT Page 11
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Table 4: RESRAD-Build Input Parameter Values for DCGLs Parameter Type8 Nuclide Treatmentb Value/Distribution Value Reference Source Air Fraction B
H-3 D
1.0NUREG/CR-6697, Att. C Section 8.6 All others 0.07 Direct Ingestion (hW)
B 2
D 9.32E-7 NUREG/CR6755, A.3.3 Removable Fraction P
1 D
0.1 NUREG-1727, Table C.7. 1; NUREG/CR-6755, section 3.5 Time for Source Removal (d)
P 0C-14, Co-60, Cs-1 37, 1-129, and Tc-99 D
52775.6 75fh percentile value Eu-1 52, Eu-1 54, and Sr-90 D
33048.9 501h percentile value Am-241, Cm-243, Cm-244, Cm-245, Cm-246, H-3, Nb-94, Ni-59, Ni-63, Np-237, Pu-238, Pu-239, D
18130.2 25h percentile value Pu-240, and Pu-241 I
Radionuclide Concentration (pCi/m2)
P 2
D 1.0 Source 4: South Wall Type P
3 area NUREG/CR-5512 Direction P
3 X
NUREG/CR-5512 site-specific data - center of floor Location of Center of Source: x,y,z (m)
P 3
D 4.24, 5.64, 1.25 based on dimensions for General Office Building room site-specific data based on Source length Y-axis (m)
P 2
D 8.47 dimensions for General Office Building room site-specific data based on Source length Z-axis (m)
P 2
D 2.49 dimensions for General Office Building room Area (M2)
P 2
D Source length inputs used Air Fraction B
H-3 D
1.0 NUREG/CR-6697, Att. C Section 8.6 All others 0.07 Direct Ingestion (h1)
B 2
D 9.32E-7 NUREG/CR6755, A.3.3 Removable Fraction P
1 D
0.1 NUREG-1727, Table C.7. 1; NUREG/CR-6755, section 3.5 V_ BARTLETT Page 12
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Table 4-RESRAD-Build Inout Parameter Values for DCGLs Parameter Type' Nuclide Treatmentb Value/Distribution Value Reference Source Time for Source Removal (d)
C-14, Co-60, Cs-137, Eu-1 54, 1-129, and Tc-99 D
52726.9 7 5th percentile value Nb-94 and Sr-90 D
33041.0 50&' percentile value Am-241, Cm-243, Cm-244, Cm-245, Cm-246, Eu-152, H-3, Ni-59, Ni-63, Np-237, Pu-238, Pu-239, D
18207.1 2 5Th percentile value
_Pu-240, and Pu-241 I
I I
Radionuclide Concentration (pCi/m
- 2)
P 2
D 1.0 1
Source 5: West Wall Type P
3 area NUREG/CR-5512 Direction P
3 Y
NUREG/CR-5512 site-specific data - center of floor Location of Center of Source: x,y,z (m)
P 3
D 8.47, 2.82, 1.25 based on dimensions for General Office Building room site-specific data based on Source length X-axis (m)
P 2D 5.64 dimensions for General Office Building room site-specific data based on Source length Z-axis (m)
P 2
D 2.49 dimensions for General Office Building room Area (m2)
P 2
D Source length inputs used H-3 1.0 Air Fraction B
All D
0.0 NUREG/CR-6697, Att. C Section 8.6 All others U.7 Direct Ingestion (Wh)
B 2
D 9.32E-7 NUREG/CR6-55, A.3.3 NUREG-1727, Table C.7.1; Removable Fraction P
1 D
0.1 NUREG/CR-6755, section 3.5 Time for Source Removal (d)
C-14, Co-60, Cs-i 37, 1-129, and Tc-99 D
52713.2 7 5th percentile value Eu-1 52, Eu-1 54, and Sr-90 D
33108.5 50" percentile value Am-241, Cm-243, Cm-244, Cm-245, Cm-246, H-3, Nb-94, Ni-59, Ni-63, Np-237, Pu-238, Pu-239, D
18094.8 2 5 Th percentile value Pu-240, and Pu-241 Radionuclide Concentration (pCi/M
- 2) p 2
D 1.0
(,
BARTLETT Page 13
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Table 4: RESRAD-Build Input Parameter Values for DCGLs Parameter Type' Nuclide Treatmentb Value/Distribution Value Reference Source Source 6: Ceiling Type P
3 area NUREG/CR-5512 Direction P
3 Y
NUREG/CR-5512 site-specific data - center of floor Location of Center of Source: x,y,z (m)
P 3
D 4.24, 2.82, 2.49 based on dimensions for General Office Building room site-specific data based on Source length X-axis (m) p 2
D 8.47 dimensions for General Office Building room site-specific data based on Source length Z-axis (m)
P 2
D 5.64 dimensions for General Office Building room Area (M2)
P 2
D Source length inputs used Air Fraction B
H-3 1.0 Air Fraction B
_All others D
0.07 NUREG/CR-6697, At. C Section 8.6 Direct Ingestion (h1)
B 2
D 9.32E-7 NUREG/CR6755, A.3.3 Removable Fraction P
1 D
0.1 NUREG-1727, Table C.7.1; NUREG/CR-6755, section 3.5 Time for Source Removal (d)
P t
C-14, Co-60, Cs-1 37, Eu-1 52, Eu-1 54,1-129, and D
52622.2 751h percentile value Nb-94 D
33050.0 50(" percentile value Sr-90 and Tc-99 Am-241, Cm-243, Cm-244, Cm-245, Cm-246, H-D 18246.6 25Th percentile value 3, Ni-59, Ni-63, Np-237, Pu-238, Pu-239, Pu-240, land Pu-241 Radionuclide Concentration (pCi/m 2)
P 2
D 1.0 aP = physical, B = behavioral, M = metabolic; (see NUREG/CR-6697, Attachment B, Table 4.)
b D = deterministic M-fBARTLETT Page 14
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Table 5: Maximum Dose at Various Evaluation Times Maximum dose (mrem) at evaluation time:
ROC Oy 1Y 5Y 10y
. 25y 50y.
Oy Am-241 1.84E-04 1.81 E-04 1.69E-04 C-14 7.90E-08 7.84E-08 7.63E-08 Cm-243 1.27E-04 1.22E-04 1.05E-04 Cm-244 9.98E-05 9.47E-05 7.65E-05 Cm-245 2.48E-04 2.45E-04 2.34E-04 Cm-246 2.04E-04 2.01 E-04 1.90E-04 Co-60 4.09E-05 3.58E-05 2.11E-05 Cs-137 1.19E-05 1.16E-05 1.05E-05 Eu-152 2.02E-05 1.92E-05 1.55E-05 Eu-154 2.15E-05 1.98E-05 1.44E-05 H-3 3.01 E-09 2.80E-09 2.1OE-09 1-129 1.12E-05 1.12E-05 1.09E-05 Nb-94 2.86E-05 2.86E-05 2.85E-05 Ni-59 8.77E-09 8.62E-09 8.01 E-09 Ni-63 2.28E-08 2.22E-08 1.99E-08 Np-237 2.27E-04 2.24E-04 2.11 E-04 Pu-238 1.60E-04 1.57E-04 1.43E-04 Pu-239 1.78E-04 1.75E-04 1.65E-04 Pu-240 1.78E-04 1.75E-04 1.65E-04 Pu-241 3.49E-06 3.56E-06 3.75E-06 3.83E-06 3.35E-06 1.93E-08 1.95E-08 Sr-90 5.71 E-06 5.52E-06 4.80E-06 Tc-99 5.76E-08 5.71 E-08 5.50E-08
(@-)BARTLETT Page 15
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Table 6: Radionuclide-Specific DCGL Values DCGL Value Development:
CF DCGL2 DCGLw Nuclide (mrem/y per 1 pCi/m2)
(pCi/m )
(dpm/100cm2)
Am-241 1.84E-04 1.36E+05 3.02E+03 C-14 7.90E-08 3.16E+08 7.03E+06 Cm-243 1.27E-04 1.97E+05 4.37E+03 Cm-244 9.98E-05 2.51 E+05 5.56E+03 Cm-245 2.48E-04 1.01 E+05 2.24E+03 Cm-246 2.04E-04 1.23E+05 2.72E+03 Co-60 4.09E-05 6.11 E+05 1.36E+04 Cs-1 37 1.19E-05 2.1 OE+06 4.66E+04 Eu-152 2.02E-05 1.24E+06 2.75E+04 Eu-154 2.15E-05 1.16E+06 2.58E+04 H-3 3.01E-09 8.31 E+09 1.84E+08 1-129 1.12E-05 2.23E+06 4.96E+04 Nb-94 2.86E-05 8.74E+05 1.94E+04 Ni-59 8.77E-09 2.85E+09 6.33E+07 Ni-63 2.28E-08 1.10E+09 2.43E+07 Np-237 2.27E-04 1.10E+05 2.44E+03 Pu-238 1.60E-04 1.56E+05 3.47E+03 Pu-239 1.78E-04 1.40E+05 3.12E+03 Pu-240 1.78E-04 1.40E+05 3.12E+03 Pu-241 3.83E-06 6.53E+06 1.45E+05 Sr-90 5.71 E-06 4.38E+06 9.72E+04 Fc-99 5.76E-08 4.34E+08 9.64E+06 Wj)BARTLETT Page 16
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Table 7: Building Surface DCGLw Values by Radionuclide Building Surface DCGLw Nuclide (dpm/1 00cm 2)
Am-241 3.OE+03 C-14 7.OE+06 Cm-243 4.3E+03 Cm-244 5.5E+03 Cm-245 2.2E+03 Cm-246 2.7E+03 Co-60 1.3E+04 Cs-1 37 4.6E+04 Eu-1 52 2.7E+04 Eu-1 54 2.5E+04 H-3 1.8E+08 1-129 4.9E+04 Nb-94 1.9E+04 Ni-59 6.3E+07 Ni-63 2.4E+07 Np-237 2.4E+03 Pu-238 3.4E+03 Pu-239 3.1 E+03 Pu-240 3.1 E+03 Pu-241 1.4E+05 Sr-90 9.7E+04 Tc-99 9.6E+06 B.ARTLETT Page 17
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Appendix A Selected Pages from RESRAD-Build Reports BARTLETT Page 18
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Am-241 Results:
RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 09:56:59 Page:
1 Title
- Humboldt Bay DCGLAm241 Input File
- C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Am241.bld RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters.............
2 Building Information.....................
3 Source Information.......................
4 For time = 0.OOE+00 yr Time Specific Parameters..............
7 Receptor-Source Dose Summary..........
10 Dose by Pathway Detail................
11 Dose by Nuclide Detail................
12 For time = 1.00E+00 yr Time Specific Parameters..............
14 Receptor-Source Dose Summary..........
17 Dose by Pathway Detail................
18 Dose by Nuclide Detail................
19 For time = 5.OOE+00 yr Time Specific Parameters..............
21 Receptor-Source Dose Summary..........
24 Dose by Pathway Detail................
25 Dose by Nuclide Detail................
26 Full Summary.............................
28 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 09:56:59 Page:
2 **
Title
- Humboldt Bay DCGLAm241 Input File : C:\\RESRADoFamily\\BUILD\\3.5\\HBDCGL-Am241.bld RESRAD-BUILD Input Parameters Number of Sources 6
Number of Receptors:
I Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information Receptor Room x
y z
FracTime Inhalation Ingestion(Dust)
[m]
[m]
[m]
[m3/day]
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+601 1.10E-04 Receptor-Source Shielding Relationship Receptor Source Densit Thickness Material
[g/cm3T
[cm]
1 1
1.OOE+00 O.OOE+00 Concrete 1
2 1.OOE+00 O.OOE+00 Concrete 1
3 1.OOE+00 O.OOE+00 Concrete 1
4 1.OOE+00 O.OOE+00 Concrete 1
5 1.OOE+00 O.OOE+00 Concrete 1
6 1.OOE400 0.OOE+00 Concrete
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 09:56:59 Page:.
3 na Title
- Humboldt Bay DCGLAm241 Input File
- C:\\RESRAD_.Family\\BUILD\\3.5\\HB.DCGL-Am241.bld Building Information Building Air Exchange Rate: 8.36E-01 1/hr Height[m]
Air Exchanges [m3/hr]
Area [m2]
=<Q01: 9.94E+01 HI:
2.490 Room 1
QI 9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 1.52E-05 [m/s]
Resuspension Rate: 1.79E-08 [t/si RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 09:56:59 Page:
4 **
(f~BARTLETT Page19
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Title : Humboldt Bay DCGL_Am241 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HB-DCGL-Am241.bld Source Information Source:
1 Location::
Room :
1 X:
4.24 y:
2.82 z:
0.00[mJ Geometry::
Type: Area Length[m]:8.47E+00 width [m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
Am-241 1.O00E+O0 3.640E-03 4.440E-01 9.554E-05 NP-237 OO.00E+00 4.444E-03 5.400E-01 1.212E-03 u-233 0.000E+00 2.890E-04 1.350E-01 1.904E-06 TH-229 0O00OE+00 4.027E-03 2.169E+00 1.741E-03 Source:
2 Location::
Room :
1 X:
4.24 y:
0.00 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.823E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pci]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
AM-241 1.OOE+O0 3.640E-03 4.440E-01 9.554E-05 NP-237 O.OOOE+00 4.444E-03 5.400E-01 1.212E-03
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 09:56:59 Page:
5
- Title : Humboldt Bay DCGLAm241 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Am241.bld u-233 O.OOOE+00 2.890E-04 1.350E-01 1.904E-06 TH-229 0.OOE+00 4.027E-03 2.169E+00 1.741E-03 Source:
3 Location::
Room :
1 X:
0.00 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.O00E-01 Time to Remove:
1.813E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
Am-241 1.OOOE+00 3.640E-03 4.440E-01 9.554E-05 NP-237 0.OOOE+00 4.444E-03 5.400E-01 1.212E-03 u-233 0.OOOE+00 2.890E-04 1.350E-01 1.904E-06 TH-229 O.OOOE+00 4.027E-03 2.169E+00 1.741E-03 Source:
4 Location::
Room :
I X:
4.24 y:
5.64 z:
1.25[m]
Geometry::
Type: Area Length[m]:S.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.00E-01 Time to Remove:
1.821E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
AM-241 1.OOOE+O0 3.640E-03 4.440E-01 9.554E-05 NP-237 0.OOOE+00 4.444P-03 5.400E-01 1.212E-03 u-233 0.OOOE+00 2.890E-04 1.350E-01 1.904E-06 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 09:56:59 Page:
6 Title : Humboldt Bay DCGLAm241 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Am241.bld TH-229 0.000E+00 4.027E-03 2.169E+00 1.741E-03 Source:
5 Location::
Room :
I x:
8.47 y:
2.82 z:
1.25[m]
110 BARTLETT Page 20
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.OOOE-02 Removable fraction:
1.O00E-01 Time to Remove:
1.809E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3))
Am-241 1.000E+00 3.640E-03 4.440E-01 9.554E-05 NP-237 0.000E+00 4.444E-03 5.400E-01 1.212E-03 u-233 0.000E+00 2.890E-04 1.350E-01 1.904E-06 TH-229 O.O00E+00 4.027E-03 2.169E+00 1.741E-03 Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.000E-02 Removable fraction:
1.0O0E-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation submersion
[pCi/m2)
[mrem/pCi)
[mrem/pCi)
[mrem/yr/
(pCi/m3)]
Am-241 1.000E+00 3.640E-03 4.440E-01 9.554E-05 NP-237 O.000E+00 4.444E-03 5.400E-01 1.212E-03 u-233 0.00OE+00 2.890E-04 1.350E-01 1.904E-06 TH-229 O.O0OE+00 4.027E-03 2.169E+00 1.741E-03
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 09:56:59 Page:
7 **
Title : Humboldt Bay DCGLAm241 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Am241.bld Evaluation Time:
O.00OOOOOOE+00 years Assessment for Time:
1 Time =0.00E+00 yr Source Information Source:
1 Location::
Room :
1 X:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.00OE-02 Removable fraction:
1.00OE-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2)
Am-241 1.OOOE+00 NP-237 O.OOOE+00 u-233 O.O00E+00 TH-229 O.OOOE+00 Source:
2 Location::
Room :
1 X:
4.24 y:
0.00 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.823E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
AM-241 1.0OOE+O0 NP-237 O.OOOE+00 U-233 O.O0OE+0 0
TH-229 0.O00E+00
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 09:56:59 Page:
8
- Title : Humboldt Bay DCGLAm241 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Am241.bld Evaluation Time:
O.0000OOOOE+OO years Source:
3 Location::
Room :
1 X:
0.00 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m):5.64E+00 width[m):2.49E+00 Direction: x Lt. eBART LETT Page 21
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time. to Remove:
1.813E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
Am-241 1.000E+00 NP-237 0.000E+00 u-233 0.0OOE+00 TH-229 0.000E+00 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+0O width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.821E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
AM-241 1.000E+00 NP-237 0.0O0E+00 u-233 0.OOOE+00 TH-229 O.O00E+00 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 09:56:59 Page:
9
- Title : Humboldt Bay DCGL_.Am241 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBJDCGL-Am241.bld Evaluation Time:
O.00000000E+00 years Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000-E02 Removable fraction:
1.000E-01 Time to Remove:
1.809E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
AM-241 1.OOOE+00 NP-237 O.OOOE+00 u-233 O.O00OE+00 TH-229 0.OOOE+00 Source:
6 Location::
ROOm :
1 X:
4.24 y:
2.82 z:
2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.825E+04 [day]
Contamination::
NuClide Concentration
[pCi/m2]
Am-241 1.000E+00 NP-237 O.O00E+00 u-233 0.000E+00 TH-229 O.OOOE400
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 09:56:59 Page:
10
- Title : Humboldt Bay DCGLAm241 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Am241.bld Evaluation Time:
0.OOOOOOOOE+00 years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mremJ Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
5.30E-05 2.33E-05 1.55E-05 2.33E-05 1.55E-05 5.29E-05 1.84E-04 Total 5.30E-05 2.33E-05 1.55E-05 2.33E-05 1.55E-05 5.29E-05 1.84E-04 (MBARTLETT Page 22
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 C-14 Results:
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:06:30 Page:
1
- Title : Humboldt Bay DCGLC14 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBSDCGL-C14.bld RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters............
2 Building Information.....................
3 Source Information.......................
4 For time = 0.0OE+00 yr Time specific Parameters..............
7 Receptor-Source Dose Summary..........
10 Dose by Pathway Detail................
11 Dose by Nuclide Detail................
12 For time = 1.00E+00 yr Time Specific Parameters..............
14 Receptor-Source Dose Summary..........
17 Dose by Pathway Detail................
18 Dose by Nuclide Detail................
19 For time = 5.09E+00 yr Time Specific Parameters..............
21 Receptor-Source Dose Summary..........
24 Dose by Pathway Detail................
25 Dose by Nuclide Detail................
26 Full Summary.............................
28
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:06:30 Page:
2 **
Title : Humboldt Bay DCGLC14 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-C14.bld RESRAD-BUILD Input Parameters Number of Sources 6
Number of Receptors:
1 Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information Receptor Room x
y z
FracTime Inhalation Ingestion(Dust)
[m]
[m]
[m]
[m3/day]
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 1.OOE-04 Receptor-Source shielding Relationship Receptor Source Density Thickness Material
[g/cm3]
[cm]
I I
1.OOE+00 O.OOE+O0 Concrete 1
2 1.OOE+00 0.OOE+00 Concrete 1
3 1.OOE+00 O.OOE+O0 Concrete 1
4 1.OOE+O0 O.OOE+O0 Concrete 1
5 1.00E+00 O.OOE+O0 Concrete 1
6 1.OOE+O0 O.OOE+O0 Concrete
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:06:30 Page:
3 Title : Humboldt Bay DCGLC14 Input File : C:\\RESRAD.Family\\BUILD\\3.S\\HBDCGL-C14.bld Building Information Building Air Exchange Rate: 8.36E-01 1/hr Height[m]
Air Exchanges [m3/hr]
Area [m2]
0
<=Q01: 9.94E+01 Hi:
2.490 Room 1 Q1O :
9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 4.78E-04 [m/s]
Resuspension Rate: 6.70E-10 [1/s]
t BARTLETT Page 23
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:06:30 Page:
4 **
Title : Humboldt Bay DCGLC14 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-C14.bld Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
5.270E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pci]
[mrem/yr/
(pCi/m3)]
C-14 1.000E+00 2.090E-06 2.090E-06 2.616E-0S Source:
2 Location::
Room :
I x:
4.24 y:
0.00 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
5.272E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
C-14 1.000E+00 2.090E-06 2.090E-06 2.616E-08 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:06:30 Page:
5
- Title : Humboldt Bay DCGLC14 Input File : C:\\RESRAD.Family\\BUILo\\3.5\\HBDCGL-C14.bld Source:
3 Location::
Room :
I x:
0.00 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
C-14 1.000E+00 2.090E-06 2.090E-06 2.616E-08 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
5.273E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
C-14 1.OOOE+00 2.090E-06 2.090E-06 2.616E-08 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:06:30 Page:
6 **
Title : Humboldt Bay OCGLC14 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-CI4.bld Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: X Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
5.271E+04 [day]
GBARTLETT Page 24
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11) ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
C-14 1.OOOE+00 2.090E-06 2.090E-06 2.616E-08 Source:
6 Location::
Room :
1 X:
4.24 y:
2.82 z:
2.49[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[i]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
5.262E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
C-14 1.000E+00 2.090E-06 2.090E-06 2.616E-08 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:06:30 Page:
7
- Title : Humboldt Bay DCGLC14 Input File : C:\\RESRADEFamily\\BUILD\\3.5\\HBDCGL-C14.bld Evaluation Time:
O.00000000E+00 years Assessment for Time:
1 Time =O.OOE+O0 yr Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:S.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.O00E-01 Time to Remove:
S.270E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
C-14 1.000E+00 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
5.272E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
C-14 1.OOOE+00 RESRAD-BUILD Dose Program Output, Version 3.50 01/2S/12 10:06:30 Page:
8 Title : Humboldt Bay DCGLC14 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-C14.bld Evaluation Time:
0.OOOOOOOOE+00 years Source:
3 Location::
Room :
1 x:
0.00 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.OOOE-01 Time to Remove:
5.278E+04 [day]
Contamination::
Nuclide Concentration
[pci/m2]
C-14 1.000E+00 Source:
4 Location::
Room :
I X:
4.24 y:
5.64 z:
1.25 [m)
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [l/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
5.273E+04 [day]
(BARTLETT Page 25
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Contamination::
Nuclide Concentration
[pCi/m2]
C-14 1.000E+00 Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.OO0E-01 Time to Remove:
5.271E+04 [day)
Contamination::
Nuclide Concentration
[pCi/m2]
C-14 1.O00OE+O0 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:06:30 Page:
9 **
Title : Humboldt Bay DCGLC14 Input File : C:\\RESRAD_Family\\BUILD\\3.5\\HBDCGL-C14.bld Evaluation Time:
0.0000000E+O0 years Source:
6 Location::
Room :
1 X:
4.24 y:
2.82 z:
2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m):S.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
S.262E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
C-14 1.000E+O0 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:06:30 Page:
10 **
Title : Humboldt Bay DCGL_C14 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-C14.bld Evaluation Time:
0.0000000OE+00 years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
2.28E-08 1.00E-08 6.67E-09 1.00E-08 6.67E-09 2.28E-08 7.90E-08 Total 2.28E-08 1.00E-08 6.67E-09 1.00E-08 6.67E-09 2.28E-08 7.90E-08 SBA RTLETT Page 26
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Cm-243 Results:
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:09:02 Page:
1 **
Title : Humboldt Bay DCGL_Cm243 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HBDCGL-Cm243.bld RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters............
2 Building Information......................
3 Source Information.......................
4 For time = O.OOE+00 yr Time Specific Parameters..............
8 Receptor-Source Dose Summary..........
11 Dose by Pathway Detail................
12 Dose by Nuclide Detail................
13 For time = 1.00E+00 yr Time Specific Parameters..............
15 Receptor-Source Dose Summary..........
18 Dose by Pathway Detail................
19 Dose by Nuclide Detail................
20 For time = 5.00E+00 yr Time Specific Parameters..............
22 Receptor-Source Dose Summary..........
25 Dose by Pathway Detail................
26 Dose by Nuclide Detail................
27 Full Summary.............................
29
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:09:02 Page:
2 **
Title : Humboldt Bay DCGL-Cm243 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HB.DCGL-Cm243.bld RESRAD-BUILD Input Parameters Number of Sources 6
Number of Receptors:
I Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information Receptor ROOm x
y z
FracTime Inhalation Ingestion(Cust)
[m]
[m]
[m]
[m3/day]
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 1.OOE-04 Receptor-Source Shielding Relationship Receptor Source Densit Thickness Material
[g/cm3 cm]
1 1
1.OOE+0OOO.00E+0 Concrete 1
2 1.OOE+O0 O.OOE+00 Concrete 1
3 1.OOE+00 O.OOE+00 Concrete 1
4 1.OOE+00 0.OOE+00 Concrete 1
5 1.00E+00 O.OOE+00 Concrete 1
6 1.OOE+00 O.OOE+00 Concrete
- iRESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:09:02 Page:
3
- Title : Humboldt Bay DCOLCm243 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm243.bld Building Information Building Air Exchange Rate: 8.36E-01 1/hr Height[m]
Air Exchanges [m3/hr]
Area [m2]
c*Q0l: 9.94E+01 Hl:
2.490 Room I
Q10 :
9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 1.52E-05 [m/s]
Resuspension Rate: 1.79E-08 [1/s]
t BARTLETT Page 27
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:09:02 Page:
4
- Title : Humboldt Say DCGLCm243 Input File : C:\\RESRAD-Family\\BUILD\\3.S\\HBDCGL-Cm243.bld Source Information Source:
I Location::
Room :
I x:
4.24 y:
2.82 z:
0.00[m]
Geometry::
Type: Area Length[m]:8.47E+00 Width[m]:5.64E+O0 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.O00E-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion tpCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
CM-243 1.OOOE+00 2.510E-03 3.070E-01 6.868E-04 PU-239 O.O000E+0 3.540E-03 4.290E-01 4.952E-07 u-235 O.OOOE+00 2.673E-04 1.230E-01 9.019E-04 PA-231 O.OOOE+00 1.060E-02 1.280E+00 2.009E-04 AC-227 O.OOOE+00 1.480E-02 6.724E+00 2.161E-03 Source:
2 Location::
Room :
1 X:
4.
Geometry::
Type: Area Pathway ::
Direct Ingestion Rate:
Fraction released to air:
Removable fraction:
Time to Remove:
24 y:
0.00 z:
1.25[m]
Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y 9.320E-07 [1/hr]
7.000E-02 1.O00E-01 1.823E+04 [day]
Contamination::'
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
CM-243 1.000E+00 2.S1OE-03 3.070E-01 6.868E-04
- RESRAD-BUILD Dose Program Output, Version 3.SO 01/25/12 10:09:02 Page:
Title : Humboldt Bay DCGLCm243 Input File : C:\\RESRAD-Family\\BUILD\\3.S\\HBDCGL-Cm243.bld Pu-239 O.000E+00 3.$40E-03 4.290E-01 4.952E-07 u-23S O.000E+00 2.673E-04 1.230E-01 9.019E-04 PA-231 O.O00E+00 1.060E-02 1.280E+00 2.009E-04 AC-227 O.OOOE+00 1.480E-02 6.724E+00 2.161E-03 5
- Source:
3 Location::
Room :
1 X:
0..
Geometry::
Type: Area Pathway ::
Direct Ingestion Rate:
Fraction released to air:
Removable fraction:
Time to Remove:
00 y:
2.82 z:
1.25[m]
Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x 9.320E-07 [1/hr]
7.OOOE-02 1.OOOE-01 1.813E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
CM-243 1.O00E+00 2.510E-03 3.070E-01 6.868E-04 PU-239 O.OOOE+00 3.540E-03 4.290E-01 4.952E-07 u-235 O.OOOE+0O 2.673E-04 1.230E-01 9.019E-04 PA-231 0.000E+00 1.060E-02 1.280E+00 2.009E-04 AC-227 O.O0OE+0O 1.480E-02 6.724E+00 2.161E-03 Source:
4 Location::
Room :
I x:
4.
Geometry::
Type: Area Pathway ::
Direct Ingestion Rate:
Fraction released to air:
Removable fraction:
Time to Remove:
24 y:
5.64 z:
1.25[m]
Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y 9.320E-07 [1/hr]
7.000E-02 1.00OE-01 1.821E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
L)BARTLETT Page 28
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:09:02 Page:
6 **
Title : Humboldt Bay DCGLCm243 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm243.bld CM-243 1.000E+00 2.510E-03 3.070E-01 6.868E-04 Pu-239 O.O00E+00 3.540E-03 4.290E-01 4.952E-07 u-235 O.O00E+00 2.673E-04 1.230E-01 9.019E-04 PA-231 0.000E+00 1.060E-02 1.280E+00 2.009E-04 AC-227 0.000E+00 1.480E-02 6.724E+00 2.161E-03 Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25[m)
Geometry::
Type: Area Length[m):5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
1.809E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi)
[mrem/pCi]
(mrem/yr/
(pCi/m3))
CM-243 1.000E+00 2.510E-03 3.070E-01 6.868E-04 Pu-239 0.000E+00 3.540E-03 4.290E-01 4.952E-07 u-235 O.O00E+00 2.673E-04 1.230E-01 9.019E-04 PA-231 O.OOOE+00 1.060E-02 1.280E+00 2.009E-04 AC-227 O.O00E+00 1.480E-02 6,724E+00 2.161E-03
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:09:02 Page:
7 **
Title : Humboldt Bay DCGLcm243 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm243.bld Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49(m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 (1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.00OE-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
(mrem/pCi]
[mrem/pCi)
[mrem/yr/
(pCi/m3))
CM-243 1.000E+00 2.510E-03 3.070E-01 6.868E-04 Pu-239 O.008E+00 3.540E-03 4.290E-01 4.952E-07 u-235 0.000E+00 2.673E-04 1.230E-01 9.019E-04 PA-231 O.008E+00 1.060E-02 1.280E+00 2.009E-04 AC-227 O.000E+00 1.480E-02 6.724E+00 2.161E-03 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:09:02 Page:
8
- Title : Humboldt Bay DCGLCm243 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm243.bld Evaluation Time:
0.00000000E+O0 years Assessment for Time:
1 Time =0.OO+O0 yr Source Information
-=
Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.825E+04 [day]
contamination::
Nuclide Concentration (pci/m2)
Cm-243 1.000E+00 Pu-239 0.O00E+00 U-235 O.O00E+00 PA-231 0.O00E+00 AC-227 O.000E+00 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m):2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.000E-02 t
SBARTLETT Page 29
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Removable fraction:
1.000E-01 Time to Remove:
1.823E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CM-243 1.O00E+00 Pu-239 O.O00E+00 u-235 O.O00E+00 PA-231 O.O00E+00 AC-227 O.000E+00
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:09:02 Page:
9
- Title : Humboldt Bay DCGLCm243 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm243.bld Evaluation Time:
O.O0000000E+00 years Source:
3 Location::
Room :
1 x:
0.00 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.O00E-01 Time to Remove:
1.813E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CM-243 1.OOOE+00 Pu-239 O.000E+00 u-235 O.O00E+00 PA-231 O.000E+00 AC-227 O.000E+00 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.821E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CM-243 1.OOOE+00 PU-239 0.O00E+00 u-235 O.OOE+00 PA-231 O.O00E+00 AC-227 O.OOOE+00
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:09:02 Page:
10
- Title : Humboldt Bay DCGL.Cm243 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HBDCGL-Cm243.bld Evaluation Time:
O.OOOOOOOOE+00 years Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOcE-O1 Time to Remove:
1.809E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CM-243 1.OOOE+00 PU-239 O.O00E+00 U-235 0.OOOE+00 PA-231 O.O00E+00 AC-227 O.OOOE+00 Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:. 2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CM-243 1.000E+00 PU-239 O.OOOE+00 U-235 O.OOOE+00 PA-231 O.OOOE+00 AC-227 O.OOOE+00 M8ARTLETT Page 30
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:09:02 Page:
11
- Title : Humboldt Bay DCGLCm243 Input File : C:\\RESRAD.Family\\BUILD\\3.S\\HBDCGL-Cm243.bld Evaluation Time:
O.00000000E+OO years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mreml Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
3.69E-05 1.61E-05 1.07E-05 1.61E-05 1.07E-05 3.67E-05 1.27E-04 Total 3.69E-05 1.61E-05 1.07E-05 1.61E-05 1.07E-05 3.67E-O5 1.27E-04 BARTLETT Page 31
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Cm-244 Results:
RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:12:41 Page:
1 Title
- Humboldt Bay DCGLCm244 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm244.bld RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters............
2 Building Information.....................
3 Source Information.......................
4 For time - 0.OO0E+0 yr Time Specific Parameters..............
8 Receptor-Source Dose Summary..........
11 Dose by Pathway Detail................
12 Dose by Nuclide Detail................
13 For time = 1.00E+00 yr Time Specific Parameters..............
15 Receptor-Source Dose Summary..........
18 Dose by Pathway Detail................
19 Dose by Nuclide Detail................
20 For time = 5.0OE+00 yr Time Specific Parameters..............
22 Receptor-Source Dose Summary..........
25 Dose by Pathway Detail................
26 Dose by Nuclide Detail................
27 Full Summary.............................
29 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:12:41 Page:
2 **
Title
- Humboldt Bay DCGL-Cm244 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm244.bld RESRAD-BUILD Input Parameters-Number of Sources 6
Number of Receptors:
I Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information
=
Receptor Room x
y z
FracTime Inhalation Ingestion(Dust)
[m]
[m]
[m]
[m3/day)
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 1.OOE-04
=
Receptor-Source shielding Relationship
=
Receptor Source Density Thickness Material 1g/cml]
[cm]
1 1
1.OOE+00 0.0OE+00 Concrete 1
2 1.OOE+00 O.00E+O0 Concrete 1
3 1.OOE+00 0.OOE+O0 Concrete 1
4 1.00E+00 O.O0E+O0 Concrete 1
5 1.OOE+00 0.OOE+00 Concrete 1
6 1.00E+00 0.OOE+00 Concrete RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:12:41 Page:
3 Title
- Humboldt Bay DCGLCm244 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HBDCGL-Cm244.bld Building Information Building Air Exchange Rate: 8.36E-01 1/hr Height[m]
Air Exchanges [m3/hr]
Area [m2]
<*Q01: 9.94E+01 HI:
2.490 Room I
Q1O :
9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 1.52E-05 [m/s]
Resuspension Rate: 1.79E-08 [1/s]
(tBARTLETT Page 32
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:12:41 Page:
4 **
Title ; Humboldt Bay DCGLCm244 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm244.bld Source Information Source:
I Location::
Room :
1 X:
4.24 y:
2.82 z:
0.00[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.825E+04 [day]
Radon Release Fraction:
1.0OOE-01 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
CM-244 1.000E+00 2.020E-03 2.480E-01 5.735E-07 PU-240 O.000E+00 3.540E-03 4.290E-01 S.548E-07 U-236 0.000E+00 2.690E-04 1.250E-01 5.852E-07 TH-232 0.000E+00 2.730E-03 1.640E+00 1.018E-06 TH-228 O.O00E+00 8.086E-04 3.454E-01 9.378E-03 RA-228 0.OOOE+00 1.442E-03 5.078E-03 5.583E-03 Source:
2 Location::
Room :
1 X:
4.24 y:
0.00 z:
1.25[m)
Geometry::
Type: Area Length[m]:8.47E+00 width(i]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000-E02 Removable fraction:
1.OOOE-01 Time to Remove:
1.823E+04 [day]
Radon Release Fraction:
1.OOOE-01 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pci/m3)]
RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:12:41 Page:
5 Title : Humboldt Bay DCGLCm244 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HB_DCGL-Cm244.bld CM-244 1.0008+00 2.020E-03 2.480E-01 5.735E-07 PU-240 0.O000E+0 3.540E-03 4.290E-01 5.548E-07 u-236 O.O00E+00 2.690E-04 1.250E-01 5.852E-07 TH-232 O.0OOE+00 2.730E-03 1.640E+00 1.018E-06 TH-228 0.000E+00 8.086E-04 3.454E-01 9.378E-03 RA-228 O.OOOE+00 1.442E-03 5.078E-03 5.583E-03 Source:
3 Location::
Room :
I X:
0.00 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Lengthfm]:5.64E+00 Width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
1.813E+04 (day]
Radon Release Fraction:
1.000E-01 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pci/m2]
[mrem/pCi]
(mrem/pCi]
(mrem/yr/
(pCi/m3)]
CM-244 1.000E+00 2.020E-03 2.480E-01 5.7358-07 Pu-240 OO.008E+0 3.5408-03 4.290E-01 5.5488-07 u-236 O.O00E+00 2.6908-04 1.250E-01 5.852E-07 TH-232 O.O00E+00 2.7308-03 1.640E+00 1.018E-06 TH-228 O.000E+00 8.086E-04 3.454E-01 9.378E-03 RA-228 O.O00E+00 1.442E-03 5.078E-03 5.583E-03
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:12:41 Page:
6
- Title : Humboldt Bay DCGLCm244 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm244.bld Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25[m]
Geometry::
Type: Area Lengthnm]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000-E02 Removable fraction:
1.000O-01 Time to Remove:
1.821E+04 [day]
Radon Release Fraction:
1.000E-01 (MBARTLETT Page 33
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
CM-244 1.OOE+00 2.020oE-03 2.480E-01 5.73SE-07 Pu-240 O.O00E+00 3.540E-03 4.290E-01 5.548E-07 u-236 O.O00oE+00 2.690E-04 1.250E-01 5.852E-07 TH-232 0.000oE+00 2.730E-03 1.640E+00 1.018E-06 TH-228 O.OOOE+0O0 8.086E-04 3.454E-01 9.378E-03 RA-228 0.000E+00 1.442E-03 5.078E-03 5.583E-03 Source:
5 Location::
Room :
1 x:
8.
Geometry::
Type: Area Pathway ::
Direct Ingestion Rate:
Fraction released to air:
Removable fraction:
Time to Remove:
Radon Release Fraction:
47 y:
2.82 z:
1.25[m)
Length[m]:5.64E+00 width[i]:2.49E+00 Direction: x 9.320E-07 [1/hr]
7.OOOE-02 1.OOOE-01 1.809E+04 [day) 1.000E-01 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
CM-244 1.000E+00 2.020E-03 2.480E-01 5.735E-07 PU-240 0.OOOE+00 3.540E-03 4.290E-01 5.548E-07 u-236 OO00oE+00 2.690E-04 1.250E-01 5.852E-07
- RESAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:12:41 Page:
7 **
Title : Humboldt Bay DCGL.Cm244 Input File : C:\\RESRAD-Family\\BUILD\\3.5\\HB-DCGL-Cm244.bld TH-232 0.OOE+00 2.730E-03 1.640E+00 1.018E-06 TH-228 0.OOOE+00 8.086E-04 3.454E-01 9.378E-03 RA-228 O.OO0E+00 1.442E-03 5.078E-03 5.583E-03 Source:
6 Location::
Room :
1 X:
4.24 y:
2.82 z:
2.49[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.825E+04 [day]
Radon Release Fraction:
1.O00E-01 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pci/m3)]
CM-244 1.OOOE+00 2.020E-03 2.480E-01 5.735E-07 Pu-240 O.O0OE+OO 3.540E-03 4.290E-01 5.548E-07 u-236 O.OOOE+00 2.690E-04 1.250E-01 5.852E-07 TH-232
.OOOOE+00 2.730E-03 1.640E+00 1.018E-06 TH-228 O.OOOE+O0 8.086E-04 3.454E-01 9.378E-03 RA-228 O.OOOE+0O 1.442E-03 5.078E-03 5.583E-03
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:12:41 Page:
8 **
Title : Humboldt Bay DCGL.Cm244 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm244.bld Evaluation Time:
0.OOOOOOOO00E+ years Assessment for Time:
1 Time =.OOE+00 yr Source Information Source:
1 Location::
Room :
1 X:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide CM-244 Pu-240 u-236 TH-232 TH-228 Concentration
[pCi/m2]
1.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00
.OOOOE+O0 BARTLETT Page 34
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 RA-228 O.0O0E+00 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 Width[m]:2.49E+00 Direction: y Pathway :
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.OOOE-02 Removable fraction:
1.O00E-01 Time to Remove:
1.823E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CM-244 1.000E+00 PU-240 O.O00E+00 u-236 O.000E+00 TH-232 O.O00E+00 TH-228 0.O00E+00 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:12:41 Page:
9 Title : Humboldt Bay DCGLCm244 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm244.bld Evaluation Time:
0.O0000000E+00 years RA-228 O.000E+00 Source:
3 Location::
Room :
1 X:
0.00 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+0O Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.813E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CM-244 1.OOOE+00 PU-240 0.OOOE+00 u-236 O.000E+00 TH-232 O.OOOE+00 TH-228 O.OOOE+00 RA-228 O.OOOE+00 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+O0 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
1.821E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CM-244 1.000E+00 PU-240 O.OOOE+00 u-236 0.OOOE+00 TH-232 0.OOOE+00 TH-228 0.OOOE+00 RA-228 0.000E+00
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:12:41 Page:
10
- Title : Humboldt Bay DCGLCm244 Input File : C:\\RESRAD-Family\\BUILD\\3.5\\HBDCGL-Cm244.bld Evaluation Time:
O.OOOOOOOOE+00 years Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.O00E-01 Time to Remove:
1.809E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
Cm-244 1.000E+00 PU-240 0.O00E+00 u-236 O.OOOE+00 TH-232 O.OOOE+00 TH-228 0.OOOE+00 RA-228 O.000E+00 Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49 [im Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.O00E-01 (MEBARTLETT Page 35
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CM-244 1.000E+00 Pu-240 0.000E+00 u-236 0.O00E+0O TH-232 0.00OE+00 TH-228 0.0OOE+0O RA-228 0.OOOE+00
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:12:41 Page:
11 **
Title : Humboldt Bay DCGLCm244 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm244.bld Evaluation Time:
0.00000000E+0O years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
2.87E-05 1.27E-05 8.46E-06 1.27E-05 8.47E-06 2.87E-05 9.98E-05 Total 2.87E-05 1.27E-05 8.46E-06 1.27E-05 8.47E-06 2.87E-05 9.98E-05 SBARTLETT Page 36
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Cm-245 Results:
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:16:05 Page:
1 **
Title : Humboldt Bay DCGL-Cm245 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm245.bld RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters............
2 Building Information.....................
3 Source Information.......................
4 For time = O.00E+00 yr Time Specific Parameters...............
8 Receptor-Source Dose Summary..........
11 Dose by Pathway Detail................
12 Dose by Nuclide Detail................
13 For time = 1.00E+00 yr Time Specific Parameters..............
15 Receptor-Source Dose Summary..........
18 Dose by Pathway Detail................
19 Dose by Nuclide Detail................
20 For time = 5.OOE+00 yr Time Specific Parameters..............
22 Receptor-Source Dose Summary..........
25 Dose by Pathway Detail................
26 Dose by Nuclide Detail................
27 Full Summary.............................
29
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:16:05 Page:
2
- Title : Humboldt Bay DCGLCm245 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBSDCGL-Cm245.bld RESRAD-BUILD Input Parameters Number of Sources 6
Number of Receptors:
1 Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information
=
Receptor Room x
y z
FracTime Inhalation Ingestion(Dust)
[m]
[ml
[im
[m3/day]
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 1.OOE-04 Receptor-Source shielding Relationship Receptor Source Density Thickness Material
[g/cm3)
[cm]
1 1
1.OOE+00 O.OOE+00 Concrete 1
2 1.OOE+00 0.OOE+00 Concrete 1
3 1.OOE+00 O.OOE+00 Concrete 1
4 1.OOE+00 O.00E+00 Concrete 1
5 1.OOE+00 0.OOE+00 Concrete 1
6 1.OOE+00 O.00E+00 Concrete
- RESRAD-BUILD Dose Program output, Version 3.50 01/25/12 10:16:05 Page:
3 **
Title : Humboldt Bay DCGL_Cm245 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm245.bld Building Information Building Air Exchange Rate: 8.36E-01 1/hr Height[m]
Air Exchanges [mi/hr]
Area (m2)
<=Q01: 9.94E+01 HI:
2.490 Room 1
Q10 :
9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 1.52E-05 [m/s]
Resuspension Rate: 6.70E-10 [1/s]
_ BARTLETT Page 37
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:16:05 Page:
4 **
Title : Humboldt Bay DCGLCm245 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HB.DCGL-Cm245.bld Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00[m)
Geometry::
Type: Area Length[m]:8.47E+00 widthm] :5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.000E-02 Removable fraction:
1.OOE-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
CM-245 Pu-241 AM-241 NP-237 u-233 TH-229 Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
1.000E+00 3.740E-03 4.550E-01 4.625E-04 0.O00E+00 6.840E-05 8.250E-03 2.555E-08 0.OOOE+00 3.640E-03 4.440E-01 9.SS4E-05 0.OOOE+00 4.444E-03 5.400E-01 1.212E-03 0.0000E+0 2.890E-04 1.350E-01 1.904E-06 0.O0OE+00 4.027E-03 2.169E+00 1.741E-03 Source:
2 Location::
ROOm :
I X:
4.24 y:
0.00 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.823E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:16:05 Page:
5 Title : Humboldt Bay DCGLCm245 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm245.bld CM-245 PU-241 AM-241 NP-237 u-233 TH-229 1.00OE+O0
- 0. OOOE+00 O.OOOE+00 0.000E+00 0.OOOE+00 0.OOE+O00 3.740E-03 6.840E-05 3.640E-03 4.444E-03 2.890E-04 4.027E-03 4.550E-01 4.625E-04 8.250E-03 2.555E-08 4.440E-01 9.554E-05 5.400E-01 1.212E-03 1.350E-01 1.904E-06 2.169E+00 1.741E-03 Source:
3 Location::
Room :
1 x:
0.00 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
I.O0OE-01 Time to Remove:
1.813E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
CM-245 Pu-241 AM-241 NP-237 U-233 TH-229 Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
1.0O0E+O0 3.740E-03 4.550E-01 4.625E-04 O.OOOE+00 6.840E-05 8.250E-03 2.55SE-08 0.OOE+O0 3.640E-03 4.440E-01 9.554E-05 0.OOOE+00 4.444E-03 5.400E-01 1.212E-03 O.OOOs+00 2.890E-04 1.350E-01 1.904E-06 O.O00E+00 4.027E-03 2.169E+00 1.741E-03
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:16:05 Page:
- Title : Humboldt Bay DCGL-Cm245 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm245.bld 6 **
Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25[m3 Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.000E-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.821E+04 [day]
t BARTLETT Page 38
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2J
[mrem/pCi)
[mrem/pCi)
[mrem/yr/
(pCi/m3)]
CM-245 1.000E+00 3.740E-03 4.550E-01 4.625E-04 Pu-241 O.O00E+00 6.840E-05 8.250E-03 2.555E-08 AM-241 O.000E+00 3.640E-03 4.440E-01 9.554E-05 NP-237 O.O00E+00 4.444E-03 5.400E-01 1.212E-03 u-233 0.000E+00 2.890E-04 1.350E-01 1.904E-06 TH-229 O.O00E+00 4.027E-03 2.169E+00 1.741E-03 Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOO-02 Removable fraction:
1.000E-01 Time to Remove:
1.809E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
CM-245 1.000E+00 3.740E-03 4.550E-01 4.625E-04 Pu-241 0.o00E+O0 6.840E-05 8.250E-03 2.555E-08 AM-241 O.O00E+00 3.640E-03 4.440E-01 9.554E-05
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:16:05 Page:
7 **
Title : Humboldt Bay DCGL-Cm245 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm245.bld NP-237 O.O00E+00 4.444E-03 5.400E-01 1.212E-03 u-233 0.OOE+O0 2.890E-04 1.350E-01 1.904E-06 TH-229 0.0OOE+00 4.027E-03 2.169E+00 1.741E-03 Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49[m]
Geometry::
Type: Area Length[ml:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3))
CM-245 1.O00E+00 3.740E-03 4.550E-01 4.625E-04 PU-241 O.O00E+00 6.840E-05 8.250E-03 2.555E-08 AM-241 O.O00E+00 3.640E-03 4.440E-01 9.554E-05 NP-237 O.O00E+00 4.444E-03 S.400E-01 1.212E-03 u-233 O.000E+00 2.890E-04 1.350E-01 1.904E-06 TH-229 O.O00E+00 4.027E-03 2.169E+00 1.741E-03 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:16:05 Page:
8 **
Title : Humboldt Bay DCGL.Cm245 Input File : C:\\RESRAD.Family\\BUILD\\3.5\\HB-DCGL-Cm245.bld Evaluation Time:
0.00000000E+00 years
-=
Assessment for Time:
1 Time =O.OOE+00 yr Source Information Source:
ILocation::
Room :
I x:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E600 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CM-245 1.OOOE+00 PU-241 O.OOOE+00 Am-241 O.O00E+00 NP-237 O.OOOE+00 u-233 0.000E+00 TH-229 O.OOOE+00 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
1.25 [m]
(fjBARTLETT Page 39
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Geometry::
Type: Area Length(m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
i.OOOE-01 Time to Remove:
1.823E+04 [day]
Contamination::
Nuclide Concentration
[pCi/mn]
CM-245 1.000E+00 Pu-241 0.OOOE+00 AM-241 0.000E+00 NP-237 0.OO0E+00 u-233 0.O00E+OO
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:16:05 Page:
9 **
Title : Humboldt Bay DCGL-Cm245 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm245.bld Evaluation Time:
O.O0000000E+00 years TH-229 O.000E+O0 Source:
3 Location::
Room :
1 x:
0.00 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.813E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CM-245 1.000E+00 PU-241 O.O00E+O0 AM-241 O.OOOE+00 NP-237 O.O00E+O0 u-233 O.OOOE+00 TH-229 O.O00E+00 Source:
4 Location::
Room :
I x:
4.24 y:
5.64 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.8211+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CM-245 1.000E+00 Pu-241 0.000E+00 AM-241 O.00OE+00 NP-237 0.000E+00 U-233 O.OOOE+00 TH-229 O.O00E+00
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:16:0S Page:
Title : Humboldt Bay DCGL-Cm245 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBtDCGL-Cm245.bld Evaluation Time:
0.O000000OE+00 years 10 **
Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.809E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CM-245 1.000E+00 Pu-241 0.000E+00 Am-241 0.OO0E+00 NP-237 0.000E+00 u-233 O.OOOE+00 TH-229 0.000E+00 Source:
6 Location::
Room :
I x:
4.24 y:
2.82 z:
2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.825E+04 [day]
BARTLETT Page 40
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Contamination::
Nuclide Concentration lPCi/m2]
CM-245 1.OOOE+00 Pu-241 0.OOOE+00 AM-241 O.OOOE+00 NP-237 O.OOOE+00 u-233 O.O00E÷00 TH-229 0.OOOE+00 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:16:05 Page:
11
- Title : Humboldt Bay DCGLCm245 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm245.bld Evaluation Time:
O.OOOOOOOOE+00 years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
8.02E-05 2.90E-05 1.80E-OS 2.90E-05 1.80E-05 7.34E-0S 2.48E-04 Total 8.02E-05 2.90E-05 1.80E-05 2.90E-05 1.80E-05 7.34E-05 2.48E-04 111 E3A RTL ETT Page 41
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Cm-246 Results:
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:20:05 Page:
1 Title : Humboldt Bay DCGLCm246 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm246.bld RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters............
2 Building information.....................
3 Source Information.......................
4 For time = O.OOE+00 yr Time Specific Parameters..............
7 Receptor-Source Dose Summary..........
10 Dose by Pathway Detail................
11 Dose by Nuclide Detail................
12 For time = 1.OOE+00 yr Time Specific Parameters..............
14 Receptor-Source Dose Summary..........
17 Dose by Pathway Detail................
18 Dose by Nuclide Detail................
19 For time = S.OOE+00 yr Time Specific Parameters..............
21 Receptor-Source Dose Summary..........
24 Dose by Pathway Detail................
25 Dose by Nuclide Detail................
26 For time = I.OOE+02 yr Time specific Parameters..............
28 Receptor-Source Dose Summary..........
31 Dose by Pathway Detail................
32 Dose by Nuclide Detail................
33 Full Summary.............................
35 (B ART LETT Page 42
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:20:05 Page:
2
- Title : Humboldt Bay DCGLcm246 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HB_DCGL-cm246.bld RESRAD-RUILD Input Parameters Number of sources 6
Number of Receptors:
1 Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information Receptor Room x
y z
FracTime Inhalation Ingestion(Dust)
[m]
[m]
[ml
[m3/day]
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 1.00E-04 Receptor-Source Shielding Relationship
==-
Receptor Source Density Thickness Material
[g/cm3]
[cm]
1 1
1.00E+00 O.OOE+00 Concrete 1
2 1.OOE+00 O.00E+00 Concrete 1
3 1.00E+00 O.OOE+00 Concrete 1
4 1.00E+00 0.00E+00 Concrete 1
5 1.00E+00 O.OOE+00 Concrete 1
6 1.OOE+00 0.00E+00 Concrete
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:20:05 Page:
3
- Title : Humboldt Bay DCGLCm246 Input File : C:\\RESRAD.Family\\BUILD\\3.5\\HBDCGL-cm246.bld Building Information Building Air Exchange Rate: 8.36E-01 1/hr Height[m]
Air Exchanges [m3/hr]
Area [m2]
- <Q01: 9.94E+01 Hi:
2.490 Room 1
QIO :
9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 1.52E-05 [m/s]
Resuspension Rate: 6.70E-10 [1/s]
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:20:05 Page:
4 **
Title : Humboldt Bay DCGLCm246 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBoDCGL-cm246.bld Source Information Source:
1 Location::
Room :
I X:
4.24 y:
2.82 z:
0.00[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
CM-246 1.000E+00 3.700E-03 4.510E-01 5.209E-07 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.0008-01 Time to Remove:
1.823E+04 [day]
t0 BARTLETT Page 43
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
CM-246 1.000E+00 3.700E-03 4.510E-01 5.209E-07 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:20:05 Page:
.5 **
Title : Humboldt Bay DCGLCm246 Input File : C:\\RESRADFaMily\\BUILD\\3.S\\HBDCGL-Cm246.bld Source:
3 Location::
Room :
1 x:
0.00 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 (1/hr)
Fraction released to air: 7.000E-02 Removable fraction:
1.OO0E-Ol Time to Remove:
1.813E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation submersion
[pci/m2]
[mrem/pci)
[mrem/pCi]
[mrem/yr/
(pCi/m3))
CM-246 1.O00E+00 3.700E-03 4.510E-01 5.209E-07 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25[m]
Geometry::
Type: Area Length[ml]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.821E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
CM-246 1.OOOE+00 3.700E-03 4.510E-01 5.209E-07
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:20:05 Page:
6 **
Title : Humboldt Bay DCGL--Cm246 Input File : C:\\RESRAD-Family\\BUILD\\3.5\\HBDCGL-Cm246.bld Source:
5 Location::
Room :
I X:
8.47 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.000E-02 Removable fraction:
1.00OE-01 Time to Remove:
1.809E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3))
CM-246 1.OOOE+00 3.700E-03 4.510E-01 5.209E-07 Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.000E-02 Removable fraction:
1.00OE-01 Time to Remove:
1.825E+04 [day)
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi)
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
CM-246 1.00OE+00 3.700E-03 4.510E-01 5.209F-07
- RESRAD-BUILD Dose Program output, version 3.50 01/25/12 10:20:05 Page:
7 **
Title : Humboldt Bay DCGLCm246 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm246.bld Evaluation Time:
0.OOOOOOOOE+00 years Assessment for Time:
1 Time =O.OOE+00 yr
rB=ARTL=ETT=
Page===
44====
Lt=.) BARTLETT, Page 44
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m]:8.47E+D0 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.OE-01 Time to Remove:
1.825E+04 [day]
contamination::
Nuclide CM-246 Concentration
[pCi/m2]
1.000E+00 Source:
2 Location::
Room :
1 X:
4.24 y:
0.00 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [3/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.00DE-g1 Time to Remove:
1.823E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CM-246 1.OD0E+00
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:20:05 Page:
8 **
Title : Humboldt Bay DCGLCm246 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HB.DCGL-Cm246.bld Evaluation Time:
O.O0000000E+00 years Source:
3 Location::
Room :
1 x:
0.00 y:
2.82 z:
Geometry::
Type: Area Length[m]:5.64E+D0 Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.O00E-01 Time to Remove:
1.813E+04 [day]
1.25 [i]
width[m]:2.49E+O0 Direction: x Contamination::
Nuclide CM-246 Concentration
[pCi/m2]
1.OOOE+00 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
Geometry::
Type: Area Length[m]:8.47E+00 Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.821E+04 [day]
1.25 [m]
width[m]:2.49E+00 Direction: y Contamination::
Nuclide CM-246 Concentration
[pCi/m2]
1.OOOE+O0 Source:
5
.Location::
Room :
1 X:
8.47 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+O0 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.ODOE-02 Removable fraction:
"1.O0E-01 Time to Remove:
1.809E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CM-246 1.000E+00
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:20:05 Page:
9 **
Title : Humboldt Bay DCGL.Cm246 Input File : C:\\RESRAD-Family\\BUILD\\3.S\\HBDCGL-Cm246.bld Evaluation Time:
O.O0000000E+00 years Source:
6 Location::
Room :
1 X:
4.24 y:
2.82 z:
2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:S.64E+00 Direction: z Pathway Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.O0E-D02 Removable fraction:
1.000E-01 (rOARTLETT Page 45 1MEARTLETT Page 45
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CM-246 1.000E+00 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:20:05 Page:
10 **
Title : Humboldt Bay DCGLCm246 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cm246.bld Evaluation Time:
O.O0000000E+O0 years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
6.14E-05 2.52E-05 1.64E-05 2.52E-05 1.64E-05 5.93E-05 2.04E-04 Total 6.14E-05 2.52E-05 1.64E-05 2.52E-05 1.64E-05 5.93E-05 2.04E-04 t9BARTLETTPae4 Page 46
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Co-60 Results:
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:22:41 Page:
1 **
Title : Humboldt Bay DCGL-co60 Input File : C:\\RESRAD.Family\\BUILD\\3.5\\HBDCGL-Co6O.bld
-=
RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters............
2 Building Information.....................
3 Source Information.......................
4 For time = 0.00E+O0 yr Time Specific Parameters..............
7 Receptor-Source Dose Summary..........
10 Dose by Pathway Detail................
11 Dose by Nuclide Detail................
12 For time = 1.00E+00 yr Time Specific Parameters..............
14 Receptor-Source Dose Summary..........
17 Dose by Pathway Detail................
18 Dose by Nuclide Detail................
19 For time = 5.O0E+O0 yr Time Specific Parameters..............
21 Receptor-Source Dose Summary..........
24 Dose by Pathway Detail................
25 Dose by Nuclide Detail................
26 Full Summary.............................
28 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:22:41 Page:
2 **
Title : Humboldt Bay DCGL.Co60 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HBDCGL-CO60.bld RESRAD-BUILD Input Parameters Number of Sources 6
Number of Receptors:
1 Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information Receptor Room x
y z
FracTime Inhalation Ingestion(Dust)
[m]
[m]
[m]
[m3/day]
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 I.OOE-04 Receptor-Source Shielding Relationship Receptor Source Densit' Thickness Material
[cm]
1 1
1.OOE+O0 O.OOE+00 Concrete 1
2 1.OOE+00 O.OOE+00 Concrete 1
3 1.OOE+00 O.OOE+00 Concrete 1
4 I.OOE+00 0.OOE+OO Concrete 1
5 1.OOE+0O 0.O0E+00 Concrete 1
6 1.OOE+00 O.OOE+OO Concrete
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:22:41 Page:
3
- Title : Humboldt Bay DCGLCo60 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBsDCGL-Co6O.bld Building Information Building Air Exchange Rate: 8.36E-01 1/hr Height[m]
Air Exchanges [m3/hr]
Area [m2]
<=Q01: 9.94E+01 HI:
2.490 Room I
Q10 :
9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 4.78E-04 [M/si Resuspension Rate: 6.70E-10 (1/s]
4)BARTLETT Page 47
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:22:41 Page:
4 **
Title : Humboldt Bay DCGLCo60 Input File : C:\\RESRAD-Family\\BUILD\\3.5\\HBDCGL-Co6O.bld Source Information Source:
1 Location::
Room :
1 X:
4.24 y:
2.82 z:
0.00[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[n]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hrl Fraction released to air: 7.OOOE-02 Removable fraction:
1.0OOE-01 Time to Remove:
S.270E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pci/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
CO-60 1.OO0E+00 2.690E-05 2.190E-04 1.472E-02 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway :
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
5.272E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
CO-60 1.OOOE+00 2.690E-05 2.190E-04 1.472E-02
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:22:41 Page:
5
- Title : Humboldt Bay DCGLCo60 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Co6O.bld Source:
3 Location::
Room :
1 x:
0.00 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.OO0E-01 Time to Remove:
5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
CO-60 1.0O0E+00 2.690E-05 2.190E-04 1.472E-02 Source:
4 Location::
Room :
1 X:
4.24 y:
5.64 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway :
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
5.273E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
Co-60 1.000E+00 2.690E-05 2.190E-04 1.472E-02 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:22:41 Page:
6
- Title : Humboldt Bay DCGLCo60 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HB.DCGL-Co60.bld Source:
5 Location::
Room :
1 X:
8.47 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:S.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
5.271E+04 [day]
(B ART LETT Page 48
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Contamination::
Nuclide Concentration
[pCi/m2]
CO-60 1.OOOE+00 Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation submersion
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
2.690E-05 2.190E-04 1.472E-02 Source:
6 Location::
Room :
I x:
4.24 y:
2.82 z:
2.49[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
5.262E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
CO-60 1.00OE+O0 2.690E-05 2.190E-04 1.472E-02
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:22:41 Page:
7 Title : Humboldt Bay DCGLCo60 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HB-DCGL-Co60.bld Evaluation Time:
O.O0000000E+00 years Assessment for Time:
1 Time =0.OOE+O0 yr Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:S.64E+00 Direction: Z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
5.270E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CO-60 1.000E+00 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
Geometry::
Type: Area Length[m]:8.47E+00 Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
5.272E+04 [day]
1.25 [m]
width[m]:2.49E+00 Direction: y Contamination::
Nuclide Concentration
[pCi/m2]
CO-60 1.000E+00 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:22:41 Page:
Title : Humboldt Bay DCGLCO60 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HB-DCGL-Co6O.bld Evaluation Time:
O.OOOOOOOOE+00 years 8 **
Source:
3 Location::
Room :
1 X:
0.00 y:
2.82 z:
Geometry::
Type: Area Length[m]:5.64E+00 Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OO0E-01 Time to Remove:
5.278E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
C0-60 1.00E4+00 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
Geometry::
Type: Area Length[m]:8.47E+00 Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.0OOE-01 Time to Remove:
5.273E+04 [day]
1.25 [m]
width[m]:2.49E+O0 Direction: x 1.25 [m]
width[m]:2.49E+00 Direction: y BARTLETT Page 49
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Contamination::
Nuclide Concentration
[pCi/m2]
CO-60 1.000E+00 Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[mn:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OooE-01 Time to Remove:
5.271E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CO-60 1.OOE+00 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:22:41 Page:
Title : Humboldt Bay DCGLCo60 Input File : C:\\RESRADoFamily\\BUILD\\3.5\\HBDCGL-Co6O.bld Evaluation Time:
0.0000000E+O0 years 9
Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m):5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.O00E-01 Time to Remove:
5.262E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CO-60 1.000E+00 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:22:41 Page:
10
- Title : Humboldt Bay DCGL-Co6O Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-CoSO.bld Evaluation Time:
0.00000000E+00 years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
1.78E-05 3.50E-06 1.45E-06 3.50E-06 1.45E-06 1.32E-05 4.09E-05 Total 1.78E-05 3.50E-06 1.45E-06 3.50E-06 1.45E-06 1.32E-05 4.09E-05 CBARTLETT Page 50
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Cs-137 Results:
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:25:02 Page:
1 **
Title : Humboldt Bay DCGL-CS137 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-CS137.bld RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters............
2 Building Information.....................
3 Source Information.......................
4 For time O.0OE+00 yr Time Specific Parameters..............
7 Receptor-Source Dose Summary..........
10 Dose by Pathway Detail................
11 Dose by Nuclide Detail................
12 For time 1
I.OOE+00 yr Time Specific Parameters..............
14 Receptor-Source Dose Summary..........
17 Dose by Pathway Detail................
18 Dose by Nuclide Detail................
19 For time = 5.00E+00 yr Time Specific Parameters..............
21 Receptor-Source Dose Summary..........
24 Dose by Pathway Detail................
25 Dose by Nuclide Detail................
26 Full Summary.............................
28
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:25:02 Page:
2 **
Title : Humboldt Bay DCGL-Cs137 Input Pile : C:\\RESRADFamily\\BUILD\\3.S\\HBDCGL-Cs137.bld RESRAD-BUILD Input Parameters Number of Sources 6
Number of Receptors:
1 Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information Receptor Room x
y Z FracTime Inhalation Ingestion(Dust)
[mD
[m]
[m]
[m3/day]
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 I.OOE-04
=
Receptor-Source Shielding Relationship
=
Receptor Source Density Thickness Material Eg/cm3]
[cm]
1 1
1.OOE+00 O.00E+O0 Concrete 1
2 1.00E+00 0.OOt+O0 Concrete 1
3 1.o0E+O0 O.00E+00 Concrete 1
4 1.OOE+00 O.OOE+00 Concrete 1
5 1.OOE+00 O.00E+OO Concrete 1
6 1.OOE+00 O.OOE+00 Concrete
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:25:02 Page:
3 **
Title : Humboldt Bay DCGL-CS137 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-CS137.bld
=...
Building Information Building Air Exchange Rate: 8.36E-01 1/hr Height[mJ Air Exchanges [m3/hr]
Area [m2]
=<QO1: 9.94E+01 Hi:
2.490 Room 1
010 :
9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 4.78E-04 Em/s]
Resuspension Rate: 6.70E-10 [1/sJ t
BARTLETT Page 51
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:25:02 Page:
4 **
Title : Humboldt Bay DCGL_Cs137 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HB.DCGL-Cs137.bld Source Information Source:
1 Location::
Room :
1 x:
4.
Geometry::
Type: Area Pathway ::
Direct Ingestion Rate:
Fraction released to air:
Removable fraction:
Time to Remove:
24 y:
2.82 z:
0.00[m]
Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z 9.320E-07 [1/hr) 7.000E-02 1.000E-01 5.270E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
Cs-137 1.O00E+00 Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[mrem/pCi)
[mrem/pCi)
[mrem/yr/
(pCi/m3)]
5.000E-05 3.190E-05 3.183E-03 Source:
2 Location::
Room :
1 x:
4.
Geometry::
Type: Area Pathway ::
Direct Ingestion Rate:
Fraction released to air:
Removable fraction:
Time to Remove:
24 y:
0.00 z:
1.25(m]
Length[m):8.47E+00 width[m]:2.49E+00 Direction: y 9.320E-07 [1/hr) 7.OOOE-02 1.O00E-01 5.272E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi)
[mrem/pCi]
[mrem/yr/
(pCi/m3))
CS-137 1.OOOE+00 5.OOOE-05 3.190E-05 3.183E-03
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:25:02 Page:
Title : Humboldt Bay DCGLCs137 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cs137.bld 5 **
Source:
3 Location::
Room :
1 X:
0.
Geometry::
Type: Area Pathway ::
Direct Ingestion Rate:
Fraction released to air:
Removable fraction:
Time to Remove:
00 y:
2.82 z:
1.25[m]
Length[m):5.64E+00 width[m):2.49E+00 Direction: x 9.320E-07 [1/hr) 7.OOOE-02 1.000E-01 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2)
[mrem/pCi)
[mrem/pCi)
[mrem/yr/
(pCi/m3))
cs-137 1.000E+00 5.000E-05 3.190E-05 3.183E-03 Source:
4Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.OOOE-02 Removable fraction:
1.00OE-01 Time to Remove:
5.273E+04 [day]
contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
cs-137 1.OOOE+00 5.OOE-O5 3.190E-05 3.183E-03
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:25:02 Page:
6 **
Title : Humboldt Bay DCGLCs137 Input File : C:\\RESRAOFamily\\BUILD\\3.5\\HBDCGL-Cs137.bld Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25[m)
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
5.271E+04 [day]
tBARTLETT Page 52
Bartlett Engineering ENG-iB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2J
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
CS-137 1.000E+00 5.000E-05 3.190E-05 3.183E-03 Source:
6 Location::
Room :
1 X:
4.24 y:
2.82 z:
2.49(m)
Geometry::
Type: Area Length[m]:8.47E+00 width[i]:S.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.O00E-02 Removable fraction:
1.000E-01 Time to Remove:
5.262E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
CS-137 1.000E+00 5.000E-05 3.190E-05 3.183E-03 RESRAD-BUILD Dos'e Program Output, version 3.50 01/25/12 10:25:02 Page:
7 **
Title : Humboldt Bay DCGL_CS137 Input File : C:\\RESRAD_.Family\\BUILD\\3.5\\HBDCGL-Cs137.bld Evaluation Time:
O.O0000000E+00 years Assessment for Time:
1 Time =O.OOE+00 yr Source Information
-=
Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway :
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.0OOE-02 Removable fraction:
1.000E-01 Time to Remove:
5.270E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CS-137 1.OOOE+00 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
5.272E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CS-137 1.000E+00 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:25:02 Page:
8
- Title : Humboldt Bay DCGLCs137 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HBDCGL-Cs137.bld Evaluation Time:
0.O0000OOOE+00 years Source:
3 Location::
Room :
1 X:
0.00 y:
2.82 z:
1.25 [in Geometry::
Type: Area Length[m):5.64E+00 width[m]:2.49E+00 Direction:. x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
5.278E+04 [day)
Contamination::
Nuclide Concentration
[pCi/m2]
CS-137 1.0O0E+O0 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.00OE-02 00 8DAR T L E TT Page 53
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Removable fraction:
Time to Remove:
Contamination::
Nuclide Cs-137 1.O00E-01 5.273E+04 [day]
Concentration
[pCi/m2]
I.OOOE+00 Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
5.271E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
cs-137 I.O00E+00
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:25:02 Page:
9 Title : Humboldt Bay DCGL-Cs137 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cs137.bld Evaluation Time:
O.OOO00000E+00 years Source:
6 Location::
Room :
1 X:
4.24 y:
2.82 z:
2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: Z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
5.262E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
CS-137 1.OOOE+00 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:25:02 Title : Humboldt Bay DCGLCs137 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Cs137.bld Evaluation Time:
O.OO000000E+00 years Page:
10 **
==
RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
4.93E-06 1.05E-06 4.99E-07 1.08E-06 5.00E-07 3.77E-06 1.19E-05 Total 4.93E-06 1.08E-06 4.99E-07 1.08E-06 5.OOE-07 3.77E-06 1.19E-05 fghBARTLETT Page 54
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Eu-152 Results:
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:30:22 Page:
1
- Title : Humboldt Bay DCGL-EU152 Input File : C:\\RESRAD-Family\\BUILD\\3.S\\HBDCGL-EulS2.bld RESRAD-BUILD Table of contents RESRAD-BUILD Input Parameters............
2 Building Information.....................
3 Source Information.......................
4 For time = 0.0OE+00 yr Time Specific Parameters..............
7 Receptor-Source Dose Summary..........
10 Dose by Pathway Detail................
11 Dose by Nuclide Detail................
12 For time = 1.00E+00 yr Time Specific Parameters..............
14 Receptor-Source Dose Summary..........
17 Dose by Pathway Detail................
18 Dose by Nuclide Detail.................
19 For time = 5.OOE+00 yr Time Specific Parameters..............
21 Receptor-Source Dose Summary..........
24 Dose by Pathway Detail................
25 Dose by Nuclide Detail.................
26 Full Summary..............................
28 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:30:22 Page:
2 **
Title : Humboldt Bay DCGLEu152 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-EulS2.bld RESRAD-BUILD Input Parameters Number of Sources 6
Number of Receptors:
1 Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information Receptor Room x
y z
FracTime Inhalation Ingestion(Dust)
[m)
[m]
[m]
[m3/day]
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 1.OOE-04 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3 cm]
1 1
1.OOE+00 O.OOE+00 Concrete 1
2 1.OOE+00 0.00E+00 Concrete 1
3 1.OOE+00 O.0E+00 Concrete 1
4 I.OOE+00 0.OOE+00 Concrete 1
5 1.OOE+00 0.OOE+OO Concrete 1
6 1.OOE+00 O.OOE+00 Concrete RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:30:22 Page:
3 **
Title : Humboldt Bay DCGL-Eu152 Input File : C:\\RESRAD-Family\\BUILD\\3.5\\HBDCGL-Eu152.bld Building Information Building Air Exchange Rate: 8.36E-01 1/hr Heightlm]
Air Exchanges [m3/hr)
Area [m2]
<=Q01: 9.94E+01 HI:
2.490 Room 1
Q10 :
9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 4.78E-04 [m/s]
Resuspension Rate: 6.70E-10 [i/s]
'AMBARLETT Page 55
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:30:22 Page:
4 **
Title : Humboldt Bay DCGLCEO152 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBLDCGL-Eu152.bld Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
O.00[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.O00E-02 Removable fraction:
1.000E-01 Time to Remove:
5.270E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
GD-152 0.000E+00 1.610E-04 2.430E-01 O.OOiE+0O EU-I52 1.O00E+O0 6.480E-06 2.210E-04 6.599E-03 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hrJ Fraction released to air: 7.000E-02 Removable fraction:
l.OOE-01 Time to Remove:
5.272E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
GD-152 O.O00E+O 1.610E-04 2.430E-01 O.OO0E+00 EU-152 1.0OOE+00 6.480E-06 2.210E-04 6.599E-03 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:30:22 Page:
S
- Title : Humboldt Bay DCGL-EU152 Input File : C:\\RESRADFaMily\\BUILD\\3.5\\HBDCGL-Eu152.bld Source:
3 Location::
Room :
I x:
0.00 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+O0 width[m]:2.49E+0O Direction: X Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.00OE-01 Time to Remove:
3.305E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
GD-152 OO00E+00 1.610E-04 2.430E-01 O.OOOE+00 EU-152 1.000E+00 6.480E-06 2.210E-04 6.599E-03 Source:
4 Location::
Room :
I X:
4.24 y:
5.64 z:
1.2S[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.821E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
GD-152 0.O00E+00 1.610E-04 2.430E-01 O.OOOE+00 EU-152 1.OOOE+00 6.480E-06 2.210E-04 6.599E-03
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:30:22 Page:
6 **
Title : Humboldt Bay DCGL-EU152 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Eui52.bld Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 t&BARTLETTTTaag 56
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Removable fraction:
1.OOOE-01 Time to Remove:
3.311E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pci]
[mrem/yr/
(pCi/m3)]
GD-152 O.O00E+00 1.610E-04 2.430E-01 O.000E+00 EU-152 1.O00E+00 6.480E-06 2.210E-04 6.599E-03 Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.00OE-01 Time to Remove:
5.262E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pci]
[mrem/yr/
(pCi/m3)]
GD-152 O.O00E+00 1.610E-04 2.430E-01 O.OOOE+00 EU-152 1.000E+00 6.480E-06 2.210E-04 6.599E-03
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:30:22 Page:
7 Title : Humboldt Bay DCGLEu152 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Eu152.bld Evaluation Time:
O.000.OOE+00 years Assessment for Time:
I Time =0.OOE+00 yr Source Information Source:
1 Location::
Room :
I x:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
I.O00E-01 Time to Remove:
5.270E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
GD-152 0.000E+00 EU-152 1.000E+00 Source:
2 Location::
Room :
1 X:
4.24 y:
0.00 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway :
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
5.272E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
GD-152 O.OOOE+00 EU-152 1.OOOE+00
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:30:22 Page:
8 Title : Humboldt Bay DCGLEu152 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Eu152.bld Evaluation Time:
0.OO000OOE+00 years Source:
3 Location::
Room :
1 X:
0.00 y:
2.82 z:
1.25 [ml Geometry::
Type: Area Length[m]:S.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
3.305E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
GD-152 O.000E+00 t BA RT LETT Page 57
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 EU-152 1.000E+00 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.821E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
GD-152 O.OOOE+00 EU-152 1.O00E+00 Source:
5 Location::
Room :
1 X:
8.47 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.00OE-01 Time to Remove:
3.311E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:30:22 Page:
9 **
Title : Humboldt Bay DCGL-Eu152 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HBDCGL-Eu152.bld Evaluation Time:
O.O000O000E+00 years GD-152 O.O00EOO00 EU-152 1.O00E+00 Source:
6 Location::
Room :
1 X:
4.24 y:
2.82 z:
2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+O0 width[m]:5.64E+00 Direction: z Pathway :
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:.
5.262E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
GD-152 O.OOOE+00 EU-152 1.OOOE+00 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:30:22 Page:
10 **
Title : Humboldt Bay DCGLEu152 Input File : C:\\RESRADPamily\\BUILD\\3.5\\HBDCGL-Eul52.bld Evaluation Time:
O.OOOOOOOOE+00 years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
8.83E-06 1.72E-06 7.09E-07 1.72E-06 7.11E-07 6.52E-06 2.02E-05 Total 8.83E-06 1.72E-06 7.09E-07 1.72E-06 7.11E-07 6.52E-06 2.02E-05 CF.BARTLETT Page 58
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Eu-154 Results:
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:31:37 Page:
1 **
Title : Humboldt Bay DCGL-Eu154 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Eu154.bld RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters............
2 Building Information.....................
3 Source Information.......................
4 For time = O.OOE+00 yr Time Specific Parameters..............
7 Receptor-Source Dose Summary..........
10 Dose by Pathway Detail................
11 Dose by Nuclide Detail................
12 For time = 1.OOE+00 yr Time Specific Parameters..............
14 Receptor-Source Dose Summary..........
17 Dose by Pathway Detail................
18 Dose by Nuclide Detail................
19 For time = 5.0OE+00 yr Time Specific Parameters..............
21 Receptor-Source Dose Summary..........
24 Dose by Pathway Detail................
25 Dose by Nuclide Detail................
26 Full Summary.............................
28 RESRAD-BUILD Dose Program output, version 3.50 01/25/12 10:31:37 Page:
2 **
Title : Humboldt Bay DCGLEul54 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-EuI54.bld RESRAD-BUILD Input Parameters Number of Sources 6
Number of Receptors:
1 Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information Receptor Room x
y z
FracTime Inhalation Ingestion(Dust)
[m]
[m]
[m]
[m3/day]
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 1.00E-04 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[gc.
cm]
1 1
1.OOE+00 O.OOE+00 Concrete 1
2 1.OOE+00 O.OOE+00 Concrete 1
3 1.OOE+00 0.OOE+OO Concrete 1
4 1.OOE+00 O.OOE+00 Concrete 1
S 1.OOE+00 0.OOE+00 Concrete 1
6 1.OOE+00 0.OOE+00 Concrete RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:31:37 Page:
3
- Title : Humboldt Bay DCGL_Eu154 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-EulS4.bld Building Information Building Air Exchange Rate: 8.36E-01 1/hr Height[m]
Air Exchanges [m3/hr]
Area [m2]
<=QO1: 9.94E+01 H1:
2.490 Room 1
q10 :
9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 4.78E-04 [m/s]
Resuspension Rate: 6.70E-10 [1/s]
(&BARTLETT S& I Page 59
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:31:37 Page:
4 **
Title : Humboldt Bay DCGLEU154 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HBDCGL-Eul54.bld Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00[mJ Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
5.270E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
EU-154 1.0006+00 9.550E-06 2.860E-04 7.172E-03 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.O00E-01 Time to Remove:
5.272E+04 (day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
EU-154 1.OO0E+00 9.550E-06 2.860E-04 7.172E-03 n* RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:31:37 Page:
5 **
Title : Humboldt Bay DCGLEu154 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Eu154.bld Source:
3 Location::
Room :
1 x:
0.00 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.00E-O1 Time to Remove:
3.305E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
(mrem/yr/
(pCi/m3)]
EU-154 1.OO0E+00 9.550E-06 2.860E-04 7.172E-03 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
5.273E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pci]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
EU-154 1.OOOE+00 9.550E-06 2.860E-04 7.172E-03
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:31:37 Page:
6 **
Title : Humboldt Bay DCGLEU154 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Eu154.bld Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25(m]
Geometry::
Type: Area Length[m]:5.64E+O0 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.O00E-01 Time to Remove:
3.311E+04 [day]
t BARTLETT Page 60
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
EU-154 1.OOOE+00 9.550E-06 2.860E-04 7.172E-03 Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49[m3 Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
5.262E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
EU-154 1.000E+00 9.550E-06 2.860E-04 7.172E-03 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:31:37 Page:
7
- Title : Humboldt Bay DCGL-Eu154 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-EU154.bld Evaluation Time:
O.O0000000E+00 years Assessment for Time:
1 Time =O.00E+00 yr
-= Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m):8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
5.270E+04 [day]
Contamination::
Nuclide concentration
[pCi/m2]
EU-154 1.000E+00 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.O00E-01 Time to Remove:
5.272E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
EU-154 1.000E+00
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:31:37 Page:
8 *u Title : Humboldt Bay DCGL-EU154 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Eu154.bld Evaluation Time:
0.O00OO00OE+00 years Source:
3 Location::
ROOm :
1 x:
0.00 y:
2.82 z:
1.25 [ml Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
3.305E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
EU-154 1.00OE+00 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway :
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 CBARTLETT Page 61
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Time to Remove:
5.273E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
EU-154 1.O00E+O0 Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+O0 width[m]:2.49E+O0 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
3.311E+04 (day]
Contamination::
Nuclide Concentration
[pCi/m2]
EU-154 1.000E+00 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:31:37 Page:
9 **
Title : Humboldt Bay DCGL-Eu1S4 Input File : C:\\RESRAD..Family\\BUILD\\3.5\\HBDCGL-EulS4.bld Evaluation Time:
O.OOOOOOOOE+00 years Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:S.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
5.262E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
EU-154 1.O00E+O0
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:31:37 Page:
10 **
Title : Humboldt Bay DCGL-Eu154 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-EU154.bld Evaluation Time:
O.O0000000E+00 years RESRAD-BUILD Dose Tables
==
-===
ý=========
=
=
=.....
-=- =-=-
Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 RecePtor 1
9.36E-06 1.83E-06 7.56E-07 1.83E-06 7.58E-07 6.92E-06 2.15E-05 Total 9.36E-06 1.83E-06 7.56E-07 1.83E-06 7.58E-07 6.92E-06 2.15E-05 W)B ART L ETT Page 62
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 H-3 Results:
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:32:46 Page:
1 **
Title : Humboldt Bay DCGL_H3 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HB_.DCGL-H3.bld
=-
RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters.............
2 Building Information.....................
3 Source Information........................
4 For time = 0.0OE+00 yr Time specific Parameters..............
7 Receptor-Source Dose Summary..........
10 Dose by Pathway Detail................
11 Dose by Nuclide Detail...............
12 For time = 1.OOE+00 yr Time Specific Parameters..............
14 Receptor-Source Dose Summary..........
17 Dose by Pathway Detail................
18 Dose by Nuclide Detail................
19 For time = 5.00E+00 yr Time Specific Parameters..............
21 Receptor-Source Dose Summary..........
24 Dose by Pathway Detail................
25 Dose by Nuclide Detail................
26 Full Summary.............................
28
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:32:46 Page:
2 **
Title : Humboldt Bay DCGLIH3 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-H3.bld RESBAD-BUILD Input Parameters Number of Sources 6
Number of Receptors:
1 Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information Receptor Room x
y z
FracTime Inhalation Ingestion(Dust)
[m]
[m]
[m]
[m3/day]
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 1.OOE-04
=
Receptor-Source Shielding Relationship
=
Receptor Source Densit Thickness Material
[g/cm3 T cmnes 1
1 1.00E+00 O.OOE+00 Concrete 1
3 1.00E+00 O.OOE+00 Concrete 1
3 1.OOE+O0 O.OOE+O0 Concrete 1
4 1.00E+00 O.OOE+00 Concrete 1
5 1.00E+00 O.OOE+00 Concrete 1
6 1.00E+00 0.OOE+00 Concrete
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:32:46 Page:
3 **
Title : Humboldt Bay DCCL_H3 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-H3.bld Building Information Building Air Exchange Rate: 8.36E-01 1/hr Height[m]
Air Exchanges [m3/hr]
Area [m2]
<=QO1: 9.94E+01 HI:
2.490 Room 1
QIO :
9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 4.78E-04 [m/s]
Resuspension Rate: 6.708-10 Il/s]
f)BARTLETT Page 63
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:32:46 Page:
4 Title : Humboldt Ray DCGLH3 Input File : C:\\RESRAD-Family\\BUILD\\3.5\\HBJDCGL-H3.bld Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00[m]
Geometry::
Type: Area Length[m]:8.47E+00 widthim]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 1.O00E+00 Removable fraction:
1.000E-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCiJ
[mrem/yr/
(pCi/m3)]
H-3 1.OOOE+00 6.400E-08 6.400E-08 3.866E-08 Source:
2 Location::
Room :
1 x:
4.
Geometry::
Type: Area Pathway ::
Direct Ingestion Rate:
Fraction released to air:
Removable fraction:
Time to Remove:
24 y:
0.00 z:
1.25[m]
Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y 9.320E-07 [1/hr]
1.000E+00 1.000E-01 1.823E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
H-3 1.OO0E+0O 6.400E-08 6.400E-08 3.866E-08 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:32:46 Page:
Title : Humboldt Bay DCGLH3 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-H3.bld 5 *.
Source:
3 Location::
Room :
1 x:
0.1 Geometry::
Type: Area Pathway ::
Direct Ingestion Rate:
Fraction released to air:
Removable fraction:
Time to Remove:
30 y:
2.82 z:
1.25[m]
Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x 9.320E-07 [1/hr]
1.OOOE+00 1.00OE-01 1.813E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
(mrem/yr/
(pCi/m3)]
H-3 1.OOOE+00 6.400E-08 6.400E-08 3.866E-08 Source:
4 Location::
Room :
1 x;
4.
Geometry::
Type: Area Pathway ::
Direct Ingestion Rate:
Fraction released to air:
Removable fraction:
Time to Remove:
24 y:
5.64 z:
1.25[m]
Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y 9.320E-07 [1/hr]
1.O00E+00 1.000E-01 1.821E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
H-3 1.OOOE+00 6.400E-08 6.400E-08 3.866E-08 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:32:46 Page:
6
- Title : Humboldt Bay DCGL-H3 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-H3.bld Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:S.64E+O0 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 1.000E+00 Removable fraction:
1.000E-01 Time to Remove:
1.809E+04 [day]
Z)BARTLETT Page 64
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
H-3 1.0OOE+00 6.400E-08 6.400E-08 3.866E-08 Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:S.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 1.000E+00 Removable fraction:
1.OoOE-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
H-3 1.000E+00 6.400E-08 6.400E-08 3.866E-08 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:32:46 Page:
7 a*
Title : Humboldt Bay DCGLH3 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-H3.bld Evaluation Time:
O.OGOOOOOOE+00 years Assessment for Time:
1 Time =O.OOE+00 yr
-..... Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 1.000E+00 Removable fraction:
1.000E-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide concentration
[pCi/m2]
H-3 1.00OE+00 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 1.000E+00 Removable fraction:
1.000E-01 Time to Remove:
1.823E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
H-3 1.000E+00 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:32:46 Page:
8 n*
Title : Humboldt Bay DCGL-H3 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HB.DCGL-H3.bld Evaluation Time:
O.0000000OE+00 years Source:
3 Location::
Room :
I x:
0.00 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:S.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 1.OOOE+00 Removable fraction:
1.OOOE-01 Time to Remove:
1.813E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
H-3 1.000E+00 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 1.000E+00 t
BARTLETT Page 65
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Removable fraction:
1.000E-01 Time to Remove:
1.821E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
H-3 1.0OOE+O0 Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [l/hr]
Fraction released to air: l.O00E+00 Removable fraction:
1.000E-01 Time to Remove:
1.809E+04 [day]
Contamination::
Nuclide Concentration
[pci/m2]
H-3 1.O00E+00 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:32:46 Page:
9 Title : Humboldt Bay DCGLH3 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HBDCGL-H3.bld Evaluation Time:
0.00000000E+00 years Source:
6 Location::
Room :
I x:
4.24 y:
2.82 z:
2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 1.000E+00 Removable fraction:
1.000E-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
H-3 1.OOOE+00
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:32:46 Page:
10 **
Title : Humboldt Bay DCGLH3 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-H3.bld Evaluation Time:
O.O0000000E+00 years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
8.66E-10 3.82E-10 2.55E-10 3.82E-10 2.55E-10 8.66E-10 3.01E-09 Total 8.66E-10 3.82E-10 2.55E-10 3.82E-10 2.55E-10 8.66E-10 3.01E-09 f&BARTLETT Page 66
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 1-129 Results:
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:34:05 Page:
1 **
Title : Humboldt Bay DCGL_I129 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-I129.bld RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters............
2 Building Information.....................
3 Source Information.......................
4 For time = O.OOE+00 yr Time Specific Parameters..............
7 Receptor-Source Dose Summary..........
10 Dose by Pathway Detail................
11 Dose by Nuclide Detail................
12 For time = 1.OOE+00 yr Time Specific Parameters..............
14 Receptor-Source Dose Summary..........
17 Dose by Pathway Detail................
18 Dose by Nuclide Detail................
19 For time = 5.OOE+00 yr Time Specific Parameters..............
21 Receptor-Source Dose Summary..........
24 Dose by Pathway Detail................
25 Dose by Nuclide Detail................
26 Full Summary.............................
28 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:34:05 Page:
2 **
Title : Humboldt Bay DCGLI129 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HBDCGL-I129.bld RESRAD-BUILD Input Parameters Number of Sources 6
Number of Receptors:
1 Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information Receptor Room x
y z
FracTime Inhalation Ingestion(Dust)
[m]
[m]
Em]
[m3/day]
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 1.00E-04
=
Receptor-Source Shielding Relationship
=
Receptor Source Density Thickness Material
[g/cm3]
[cm]
1 1
1.OOE+00 0.0OE+00 Concrete 1
2 1.0OE+00 0.0OE+00 Concrete 1
3 1.OOE+00 0.OOE+O0 Concrete 1
4 1.00E+00 0.00E+OO0 Concrete 1
5 1.OOE+00 0.OOE+O0 Concrete 1
6 1.OOE+00 0.OOE+O0 Concrete 4
RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:34:05 Page:
3.4 Title : Humboldt Bay DCGLI129 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-I129.bld
-===
Building Information Building Air Exchange Rate: 8.36E-01 1/hr Height[m]
Air Exchanges [m3/hr]
Area [m2
<=q0l: 9.94E+01 HI:
2.490 Room I
Q10 :
9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 4.78E-04 Em/a] Resuspension Rate: 6.70E-10 [1/si t
GBARTLETT Page 67
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:34:05 Page:
4 **
Title : Humboldt Bay DCGL_1129 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-1129.bld Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway Direct Ingestion Rate:
9.320E-07 (1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
5.270E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
1-129 1.000E+00 2.760E-04 1.740E-04 4.438E-05 source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
5.272E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
1-129 1.OOOE+00 2.760E-04 1.740E-04 4.438E-05 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:34:05 Page:
5 **
Title : Humboldt Bay DCGL-1129 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-I129.bld Source:
3
.Location::
Room :
I x:
0.00 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:S.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
(mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
1-129 1.OOOE+00 2.760E-04 1.740E-04 4.438E-05 Source:
4 Location::
Room :
I X:
4.24 y:
5.64 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
5.273E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
1-129 1.OOOE+00 2.760E-04 1.740E-04 4.438E-05
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:34:05 Page:
6 **
Title : Humboldt Bay DCGL-I129 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-I129.bld Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.OOOE-01 Time to Remove:
5.271E+04 [day]
t BARTLETT Page 68
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
(mrem/yr/
(pCi/m3)]
1-129 1.000E+0O 2.760E-04 1.740E-04 4.438E-05 Source:
6 Location::
Room :
1 X:
4.24 y:
2.82 z:
2.49[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[ml]:S.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
5.262E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
1-129 1.O00E+00 2.760E-04 1.740E-04 4.438E-05 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:34:05 Page:
7 **
Title : Humboldt Bay DCGLI129 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-i129.bld Evaluation Time:
O.O0000000E+00 years Assessment for Time:
I Time =O.00E+00 yr
-==
=
Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
5.270E+04 [day]
Contamination::
Nuclide 1-129 Concentration
[pCi/m2]
1.OOOE+00 Source:
2 Location::
Room :
1 X:
4.24 y:
0.00 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.OOOE-01 Time to Remove:
5.272E+04 (day]
Contamination::
Nuclide Concentration
[pCi/m2]
1-129 1.OOOE+00
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:34:05 Page:
Title : Humboldt Bay DCGL1I129 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HBDCGL-129.bld Evaluation Time:
0.OOOOOOOOE+00 years 8
- Source:
3 Location::
Room :
1 X:
0.00 y:
2.82 z:
Geometry::
Type: Area Length[m]:5.64E+00 Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
5.278E+04 [day]
1.25 [m]
width[m]:2.49E+00 Direction: x Contamination::
Nuclide 1-129 Concentration
[pCi/m2]
1.OOOE+00 Source:
4 Location::
Room :
1 X:
4.24 y:
5.64 z:
Geometry::
Type: Area Length[m]:8.47E+00 Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.O00E-01 Time to Remove:
5.273E+04 [day]
1.25 [m]
width[m]:2.49E+00 Direction: y tSBARTLETT Page 69
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Contamination::
Nuclide Concentration
[pCi/m2]
1-129 1.OOOE+00 Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+O0 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.O00E-01 Time to Remove:
5.271E+04 [day)
Contamination::
Nuclide Concentration
[pCi/m2]
1-129 1.000E+00
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:34:05 Page:
9 **
Title : Humboldt Bay DCGL_1129 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-1129.bld Evaluation Time:
O.OOOOOOOOE+00 years Source:
6 Location::
Room :
I X:
4.24 y:
2.82 z:
2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+O0 width[m]:S.64E+0O Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
5.262E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
1-129 1.000E+00 n* RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:34:05 Page:
10 **
Title : Humboldt Bay DCGLI129 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-i129.bld Evaluation Time:
O.OOOO0OOOE+00 years RESRAD-BUILD Dose Tables
=
-- - - - -- -=
=
= - -
Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
3.33E-06 1.40E-06 9.10E-07 1.40E-06 9.11E-07 3.28E-06 1.12E-05 Total 3.33E-06 1.40E-06 9.10E-07 1.40E-06 9.11E-07 3.28E-06 1.12E-05 t
BARTLETT Page 70
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Nb-94 Results:
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:36:17 Page:
1
- Title : Humboldt Bay DCGLNb94 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Nb94.bld RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters............
2 Building Information.....................
3 Source Information.......................
4 For time = O.OOE+00 yr Time Specific Parameters..............
7 Receptor-Source Dose Summary..........
10 Dose by Pathway Detail................
11 Dose by Nuclide Detail................
12 For time = 1.00E+00 yr Time Specific Parameters..............
14 Receptor-Source Dose Summary..........
17 Dose by Pathway Detail................
18 Dose by Nuclide Detail................
19 For time = 5.00E+00 yr Time Specific Parameters..............
21 Receptor-Source Dose Summary..........
24 Dose by Pathway Detail................
25 Dose by Nuclide Detail................
26 Full Summary.............................
28
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:36:17 Page:
2 **
Title : Humboldt Bay DCGLNb94 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Nb94.bld RESRAD-BUILD Input Parameters Number of Sources 6
Number of Receptors:
1 Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information Receptor Room x
y z
FracTime Inhalation Ingestion(Dust)
[m]
[m]
[m]
[m3/day]
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 1.OOE-04 Receptor-Source shielding Relationship Receptor Source Densit '
Thickness Material 1g/cm31
[cm C
1 1
1.OOE+O0 0.00E+00 Concrete 1
2 1.OOE+00 O.OOE+00 Concrete 1
3 1.00E+00 O.OOE+00 Concrete 1
4 I.OOE+O0 O.OOE+O0 Concrete 1
5 1.OOE+00 0.OOE+00 Concrete 1
6 1.00E+O0 0.OOE+00 Concrete RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:36:17 Page:
3
- Title : Humboldt Bay DCGLNb94 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Nb94.bld Building Information Building Air Exchange Rate: 8.36E-01 1/hr Height[m]
Air Exchanges [m3/hr]
Area [m2)
<=QO1: 9.94E+01 Hi:
2.490 Room 1
Q1O :
9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 4.78E-04 [m/s]
Resuspension Rate: 6.70E-10 [i/s]
- 'BARTLETT Page 71
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:36:17 Page:
4 **
Title : Humboldt Bay DCGL.Nb94 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Nb94.bld Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
O.00[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+O0 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.00OE-01 Time to Remove:
5.270E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
NB-94 1.OOOE+00 7.140E-06 4.140E-04 8.994E-03 Source:
2 Location::
Room :
1 X:
4.24 y:
0.00 z:
1.25(m]
Geometry::
Type: Area Length[m):8.47E+00 width[m]:2.49E+O0 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.OO0E-01 Time to Remove:
3.320E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
( pCi/m3)]
NB-94 1.OOOE+O0 7.140E-06 4.140E-04 8.994E-03 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:36:17 Page:
5 **
Title : Humboldt Bay DCGLNb94 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HBDCGL-Nb94.bld Source:
3 Location::
Room :
1 X:
0.00 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:S.64E+00 width[m]:2.49E+O0 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.813E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
NB-94 1.000E+00 7.140E-06 4.140E-04 8.994E-03 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+O0 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.OOOE-01 Time to Remove:
3.304E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
NB-94 1.OOOE+00 7.140E-06 4.140E-04 8.994E-03
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:36:17 Page:
6 **
Title : Humboldt Bay DCGLNb94 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Nb94.bld Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+O0 width[m]:2.49E+O0 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
1.809E+04 [day]
t BARTLETT Page 72
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
NB-94 1.O00E+00 7.140E-06 4.140E-04 8.994E-03 Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[i]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
5.262E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
NB-94 1.000E+00 7.140E-06 4.140E-04 8.994E-03 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:36:17 Page:
7 **
Title : Humboldt Bay DCGL.Nb94 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Nb94.bld Evaluation Time:
O.OOOOOOOOE+00 years Assessment for Time:
I Time =0.OOE+00 yr Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.0OOE-02 Removable fraction:
1.00OE-01 Time to Remove:
5.270E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
NB-94 1.OOOE+00 Source:
2 Location::
Room :
I x:
4.24 y:
0.00 z:
1.25 [m)
Geometry::
Type: Area Length[m]:8.47E+00 Width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.O00E-01 Time to Remove:
3.320E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
NB-94 1.OOOE+0O
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:36:17 Page:
8 **
Title : Humboldt Bay DCGLNb94 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Nb94.bld Evaluation Time:
O.O000000OE+00 years Source:
3 Location::
Room :
I x:
0.00 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.813E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
NB-94 1.OOOE+00 Source:
4 Location::
Room :
I x:
4.24 y:
5.64 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 B9 E ART L ETT Page 73
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Removable fraction:
1.OOOE-01 Time to Remove:
3.304E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
NB-94 1.000E+0O Source:
5 Location::
Room :
1 X:
8.47 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-O1 Time to Remove:
1.809E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
NB-94 1.OOOE+00 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:36:17 Page:
9 Title : Humboldt Bay DCGLNb94 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HBRDCGL-Nb94.bld Evaluation Time:
O.O0000000E+00 years Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+OO width[m]:5.64E+O0 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
5.262E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
NB-94 1.OO0E+00 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:36:17 Page:
10
- Title : Humboldt Bay DCGLNb94 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Nb94.bld Evaluation Time:
0.OO000OOOE+00 years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
1.25E-05 2.44E-06 1.01E-06 2.44E-06 1.02E-06 9.21E-06 2.86E-05 Total 1.25E-05 2.44E-06 1.01E-06 2.44E-06 1.02E-06 9.21E-06 2.86E-05 SB ART L ETT Page 74
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Ni-59 Results:
RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:37:29 Page:
1 Title : Humboldt Bay DCGLNi59 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HB.DCGL-NiS9.bld RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters............
2 Building Information.....................
3 Source Information.......................
4 For time = O.OOE+00 yr Time Specific Parameters..............
7 Receptor-Source Dose Summary..........
10 Dose by Pathway Detail................
11 Dose by Nuclide Detail................
12 For time = 1.OOE+00 yr Time Specific Parameters..............
14 Receptor-Source Dose Summary..........
17 Dose by Pathway Detail................
18 Dose by Nuclide Detail................
19 For time = 5.00E+00 yr Time Specific Parameters..............
21 Receptor-Source Dose Summary..........
24 Dose by Pathway Detail................
25 Dose by Nuclide Detail................
26 Full Summary.............................
28 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:37:29 Page:
2
- Title
- Humboldt Bay DCGLNi59 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Ni59.bld RESRAD-BUILD Input Parameters Number of Sources 6
Number of Receptors:
I Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information Receptor Room x
y z
FracTime Inhalation Ingestion(Dust)
[m]
[m]
[m]
[m3/day]
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 1.00E-04
=
Receptor-Source Shielding Relationship
=
Receptor Source Densit Thickness Material
[g/cm3]
[cm]
I 1
1.OOE+00 O.OOE+00 Concrete 1
2 1.OOE+00 O.00E+00 Concrete 1
3 1.00E+00 O.OOE+00 Concrete 1
4 1.OOE+00 0.OOE+O0 Concrete 1
5 1.00E+00 O.OOE+00 Concrete 1
6 1.0OE+O0 0.OOE+00 Concrete RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:37:29 Page:
3 **
Title
- Humboldt Bay DCGLNi59 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-NiS9.bld
-=
=
Building Information Building Air Exchange Rate: 8.36E-01 1/hr Height[m]
Air Exchanges [m3/hr]
Area [m2]
<=<01: 9.94E+01 Hi:
2.490 Room 1
Q1O :
9.94E401 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 4.78E-04 [m/s]
Resuspension Rate: 6.70E-10 [1/s]
t BARTLETT Page 75
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:37:29 Page:
4 **
Title : Humboldt Bay DCGLNi59 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Ni59.bld Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway :
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
I.OOOE-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation submersion
[pCi/m2]
[mrem/pCi]
(mrem/pCi]
[mrem/yr/
(pCi/m3)]
NI-59 1.O00E+00 2.100E-07 2.700E-06 O.O00E+00 Source:
2 Location::
Room :
1 X:
4.24 y:
0.00 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway :
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.O00E-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.823E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
NI-59 1.OO0E+O0 2.100E-07 2.700E-06 O.O00E+D0 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:37:29 Page:
5 **
Title : Humboldt Bay DCGLNi59 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Ni59.bld Source:
3 Location::
Room :
1 x:
0.00 y:
2.82 z:
1.25[m)
Geometry::
Type: Area Length[m]:5.64E+00 widthEm]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 (1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.813E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
NI-59 1.O00E+O0 2.100E-07 2.700E-06 O.OOOE+00 Source:
4 Location::
Room :
1 X:
4.24 y:
5.64 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.821E+04 (day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
NI-59 1.O00E+00 2.100E-07 2.700E-06 O.OOOE+00 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:37:29 Page:
6 **
Title : Humboldt Bay DCGLNi59 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Ni59.bld Source:
5 Location::
Room :
1 X:
8.47 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 (1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.809E+04 [day]
t BA R.T L ETT Page 76
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
NI-59 1.000E+00 2.100E-.07 2.700E-06 O.OOOE+00 Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49[m)
Geometry::
Type: Area Length[m]:8.47E+00 widthim]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
I.00E-OI Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
NI-59 1.000E+00 2.100E-07 2.700E-06 O.000E+00
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:37:29 Page:
7
- Title : Humboldt Bay DCGLNi59 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-NiS9.bld Evaluation Time:
O.OOOOOOOOE+0O years Assessment for Time:
I Time =O.OOE+00 yr Source Information source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m):8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide NI-59 Concentration
[pCi/m2]
1.O00E+00 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 Width[m]:2.49E+O0 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.O00E-01 Time to Remove:
1.823E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
NI-59 1.OOOE+00
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:37:29 Page:
8 **
Title : Humboldt Bay DCGLNi59 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Ni59.bld Evaluation Time:
O.O0000000E+00 years Source:
3 Location::
Room :
1 x:
0.00 y:
2.82 z:
Geometry::
Type: Area Length[m]:5.64E+00 Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.813E+04 [day]
1.25 [m]
width[m]:2.49E+00 Direction: x Contamination::
Nuclide Ni-59 Concentration
[pCi/m2) 1.000E+O0 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
Geometry::
Type: Area Length[m]:8.47E+00 Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.821E+04 [day]
1.25 [m]
width[m]:2.49E+00 Direction: y BARTLETT Page 77
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Contamination::
Nuclide NI-59 Concentration
[pCi/m2]
1.O00E+00 Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:S.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.809E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
NI-59 1.OOOE+00
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:37:29 Page:
Title : Humboldt Bay DCGLNi59 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-NiS9.bld Evaluation Time:
O.OOO00000E+OO years 9 **
Source:
6 Location::
Room :
1 X:
4.24 y:
2.82 z:
2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.O00E-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
NI-59 1.000E+00
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:37:29 Page:
10
- Title : Humboldt Bay DCGLNi59 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Ni59.bld Evaluation Time:
O.OOOOOOOOE+OO years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
2.53E-09 1.12E-09 7.43E-10 1.12E-09 7.43E-10 2.53E-09 8.77E-09 Total 2.53E-09 1.12E-09 7.43E-10 1.12E-09 7.43E-10 2.53E-09 8.77E-09
(/SBARTLETT Page 78
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Ni-63 Results:
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:38:29 Page:
1 **
Title : Humboldt Bay DCGL_Ni63 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Ni63.bld RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters............
2 Building Information.....................
3 Source Information.......................
4 For time = 0.OOE+00 yr Time Specific Parameters..............
7 Receptor-Source Dose Summary..........
10 Dose by Pathway Detail................
11 Dose by Nuclide Detail................
12 For time = 1.OOE+00 yr Time Specific Parameters..............
14 Receptor-Source Dose Summary..........
17 Dose by Pathway Detail................
18 Dose by Nuclide Detail.................
19 For time = 5.OOE+00 yr Time Specific Parameters..............
21 Receptor-Source Dose Summary..........
24 Dose by Pathway Detail................
25 Dose by Nuclide Detail................
26 For time = 1.OOE+01 yr Time Specific Parameters..............
28 Receptor-Source Dose Summary..........
31 Dose by Pathway Detail................
32 Dose by Nuclide Detail................
33 Full Summary.............................
35
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:38:29 Page:
2 **
Title : Humboldt Bay DCGLNi63 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Ni63.bld RESRAD-BUILD Input Parameters Number of Sources 6
Number of Receptors:
1 Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information Receptor Room x
y z
FracTime Inhalation Ingestion(Dust)
[im]
[im]
[im]
[m3/day]
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 1.OOE-04
=
Receptor-Source Shielding Relationship
=
Receptor Source Densit Thickness Material
[g/cm3T
[cm]
1 1
1.OOE+00 O.OOE+00 Concrete 1
2 1.OOE+00 O.OOE+0O Concrete 1
3 1.OOE+00 O.OOE+00 Concrete 1
4 1.OOE+00 O.OOE+00 Concrete 1
5 1.00E+00 0.OOE+00 Concrete 1
6 1.OOE+00 O.OOE+00 Concrete RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:38:29 Page:
3 Title : Humboldt Bay DCGL_Ni63 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Ni63.bld Building Information Building Air Exchange Rate: 8.36E-01 1/hr Height[m]
Air Exchanges [m3/hr]
Area [m2]
<=QO1: 9.94E+01 HI:
2.490 Room 1
Q10 :
9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 4.78E-04 [m/s]
Resuspension Rate: 6.70E-10 [1/s]
tBARTLETT Page 79
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:38:29 Page:
4
- Title : Humboldt Bay DCGLNi63 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Ni63.bld Source Information Source:
1 Location::
Room :
1 X:
4.24 y:
2.82 z:
0.00(m]
Geometry::
Type: Area Length[m]:8.47E+00 Width[m):5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.00OE-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCiJ
[mrem/pci]
[mrem/yr/
(pCi/m3)]
NI-63 1.000E+00 5.770E-07 6.290E-06 O.OOOE+00 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m):2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.823E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
Ni-63 1.O00E+00 5.770E-07 6.290E-06 0.OOOE+00
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:38:29 Page:
5
- Title : Humboldt Bay DCGLNi63 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Ni63.bld Source:
3 Location::
Room :
I x:
0.00 y:
2.82 z:
1.25(m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.813E+04 [day)
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi)
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
NI-63 1.OOOE+00 5.770E-07 6.290E-06 0.O00E+O0 Source:
4 Location::
Room :
I X:
4.24 y:
5.64 z:
1.25(m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.821E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
(mrem/pCi]
[mrem/pci]
[mrem/yr/
(pCi/m3)]
NI-63 1.000E+O0 5.770E-07 6.290E-06 0.O00E+00
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:38:29 Page:
6
- Title : Humboldt Bay DCGLNi63 Input File : C:\\RESRAD-Family\\BUILD\\3.5\\HBDCGL-Ni63.bld Source:
5 Location::
Room :
1 X:
8.47 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
1.809E+04 [day]
(&BARTLETT Page 80
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
NI-63 1.0OOE+00 5.770E-07 6.290E-06 O.OOOE+00 Source:
6 Location::
Room :
1 X:
4.24 y:
2.82 z:
2.49[m]
Geometry::
Type: Area Length[m]:8.47E+00 widthto]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
NI-63 1.OOOE+00 5.770E-07 6.290E-06 O.O00E+00 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:38:29 Page:
7 **
Title : Humboldt Bay DCGLNi63 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Ni63.bld Evaluation Time:
O.OOOOOOOOE+00 years Assessment for Time:
1 Time =O.OOE+O0 yr Source Information Source:
1 Location::
Room :
1 X:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
I.OOE-Ol Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
NI-63 1.OOOE+00 Source:
2 Location::
Room :
I x:
4.24 y:
0.00 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 Width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
l.OOOE-Ol Time to Remove:
1.823E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
NI-63 1.000E+00
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:38:29 Page:
8 **
Title : Humboldt Bay DCGLNi63 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Ni63.bld Evaluation Time:
O.O0000000E+00 years Source:
3 Location::
Room :
1 x:
0.00 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.813E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
NI-63 1.OOOE+00 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25 [ml Geometry::
Type: Area Length[n]:8.47E+00 width[m]:2.49E+00 pirection: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.821E+04 [day]
t BARTLETT Page 81
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Contamination::
Nuclide Concentration
[pCi/m2]
NI-63 1.000E+00 Source:
5 Location::
Room :
1 X:
8.47 y:
2.82 z:
1.25 [mJ Geometry::
Type: Area Length[m]:5.64E+0O width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.O00E-O1 Time to Remove:
1.809E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
NI-63 1.000E+00
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:38:29 Page:
9 **
Title : Humboldt Bay DCGLNi63 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Ni63.bld Evaluation Time:
O.O000000OE+O0 years Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+O0 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
I.O00E-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
NI-63 1.000E.00 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:38:29 Page:
10
- Title : Humboldt Bay DCGLNi63 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Ni63.bld Evaluation Time:
O.OOOOOOOOE+O0 years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
6.56E-09 2.90E-09 1.93E-09 2.90E-09 1.93E-09 6.56E-09 2.28E-08 Total 6.56E-09 2.90E-09 1.93E-09 2.90E-09 1.93E-09 6.56E-09 2.28E-08
~g)6ARTLETT Page 82 tMARTLETT Page 82
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Np-237 Results:
RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:39:32 Page:
1
- Title : Humboldt Bay DCGLNp237 Input File C:\\RESRADFamily\\BUILD\\3.S\\HBDCGL-Np237.bld RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters............
2 Building Information.....................
3 Source Information.......................
4 For time = O.OOE+00 yr Time Specific Parameters..............
7 Receptor-Source Dose Summary..........
10 Dose by Pathway Detail................
11 Dose by Nuclide Detail................
12 For time = 1.00E+00 yr Time Specific Parameters..............
14 Receptor-Source Dose Summary..........
17 Dose by Pathway Detail................
18 Dose by Nuclide Detail................
19 For time = 5.0OE+00 yr Time Specific Parameters..............
21 Receptor-Source Dose Summary..........
24 Dose by Pathway Detail................
25 Dose by Nuclide Detail................
26 Full Summary.............................
28
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:39:32 Page:
2 **
Title : Humboldt Bay DCGLNp237 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Np237.bld RESRAD-BUILD Input Parameters Number of Sources 6
Number of Receptors:
1 Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information Receptor Room x
y z
FracTime Inhalation Ingestion(Dust)
[m]
[m]
[m]
[m3/day]
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 1.OOE-04 Receptor-Source Shielding Relationship Receptor Source Densit Thickness Material Recptr ouce
[g/cm3T c.
1 1
1.OOE+00 O.OOE+00 Concrete 1
2 1.OOE+00 O.OOE+00 Concrete 1
3 1.OOE+00 0.00E+00 Concrete 1
4 1.OOE+00 0.OoE+00 Concrete 1
5 1.OOE+00 0.oOE+00 Concrete 1
6 1.OOE+00 0.OOs+00 Concrete
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:39:32 Page:
3 **
Title : Humboldt Bay DCGLNp237 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HB-DCGL-Np237.bld Building Information Building Air Exchange Rate: 8.36E-01 1/hr Height[m]
Air Exchanges (m3/hr]
Area [m2]
<=oOl: 9.94E+01 Hi:
2.490 Room 1
010 :
9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 1.52E-05 (n/sI Resuspension Rate: 1.79E-08 [1/s) t BARTLETT Page 83
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:39:32 Page:
4
- Title : Humboldt Bay DCGLNp237 Input File : C:\\RESRADFami1y\\BUILD\\3.5\\HBDCGL-Np237.bld Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
NP-237 1.00OE+00 4.444E-03 5.400E-01 1.212E-03 u-233 0.O0E+00 2.890E-04 1.350E-01 1.904E-06 TH-229 O.OO0E+0 0
4.027E-03 2.169E+00 1.741E-03 Source:
2 Location::
Room :
1 X:
4.24 y:
0.00 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 Width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.823E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
NP-237 1.00OE+00 4.444E-03 5.400E-01 1.212E-03 u-233 0.OO0E+00 2.890E-04 1.350E-01 1.904E-06 TH-229 0.00OE+O0 4.027E-03 2.169E+00 1.741E-03 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:39:32 Page:
5 **
Title : Humboldt Bay DCGLNp 237 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HBDCGL-Np237.bld Source:
3 Location::
Room :
I x:
0.00 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.813E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
NP-237 1.0006E+0 4.444E-03 5.400E-01 1.212E-03 u-233 0.O006E+0 2.890E-04 1.350E-01 1.904E-06 TH-229 00006E+O0 4.027E-03 2.169E+00 1.741E-03 Source:
4 Location::
Room :
1 X:
4.24 y:
5.64 z:
1.25(m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.821E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
(mrem/yr/
(pCi/m3)]
NP-237 1.OOOE+00 4.444E-03 5.400E-01 1.212E-03 u-233 O.006E+0 2.890E-04 1.350E-01 1.904E-06 TH-229 O.006E+0 4.027E-03 2.169E+00 1.741E-03 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:39:32 Page:
6
- Title : Humboldt Bay DCGLNp237 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Np237.bld Source:
5 Location::
Room :
1 X:
8.47 y:
2.82 z:
1.25(m3 t
BARTLETT Page 84
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Geometry::
Type: Area Length[m):5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.809E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3))
NP-237 1.O00E+O0 4.444E-03 5.400E-01 1.212E-03 u-233 O.OOOE+00 2.890E-04 1.350E-01 1.904E-06 TH-229 0.000E+00 4.027E-03 2.169E+00 1.741E-03 Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.O00E-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2n
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3))
NP-237 1.000E+00 4.444E-03 5.400E-01 1.212E-03 u-233 0.000E+00 2.890E-04 1.350E-01 1.904E-06 TH-229 0.000E+00 4.027E-03 2.169E+00 1.741E-03
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:39:32 Page:
7 **
Title : Humboldt Bay DCGLNp237 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Np237.bld Evaluation Time:
O.OOOOOOOOE+00 years Assessment for Time:
1 Time =O.OOE+0O yr Source Information Source:
1 Location::
Room :
1 X:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:S.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2i NP-237 1.000E+00 u-233 O.OOOE+00 TH-229 O.OOOE+00 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.823E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
NP-237 1.0O0E+00 u-233 O.OOOE+00 TH-229 O.OOOE+00
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:39:32 Page:
8 **
Title : Humboldt Ray DCGLNp237 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Np237.bld Evaluation Time:
O.OOOOOOOOE+00 years Source:
3 Location::
Room :
I x:
0.00 y:
2.82 z:
1.25 [ml Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOcE-Ol t9 BARTLETT Page 85
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Time to Remove:
1.813E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
NP-237 I.OOOE+O0 u-233 O.OOOE+00 TH-229 O.O00E+00 Source:
4 Location::
Room :
1 X:
4.24 y:
5.64 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.821E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
NP-237 1.000E+O0 u-233 O.OOOE+O0 TH-229 O.OOOE+O0 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:39:32 Page:
9 **
Title : Humboldt Bay DCGLNp23 7
Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBSDCGL-Np237.bld Evaluation Time:
0.O0000000E+0O years Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.809E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
NP-237 1.000E+00 u-233 O.O00E+00 TH-229 O.O00E+00 Source:
6 Location::
Room :
1 X:
4.24 y:
2.82 z:
2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
NP-237 1.000E+00 u-233 0.O00E+O0 TH-229 0.O00E+00 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:39:32 Page:
10 **
Title : Humboldt Bay DCGLNp237 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Np237.bld Evaluation Time:
0.OQOOOOOOE+00 years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
6.62E-05 2.87E-05 1.91E-05 2.88E-05 1.91E-05 6.57E-05 2.27E-04 Total 6.62E-05 2.87E-05 1.91E-05 2.88E-05 1.91E-05 6.57E-05 2.27E-04 t
BARTLETT Page 86
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Pu-238 Results:
RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:41:26 Page:
1
- Title : Humboldt Bay DCGLPu238 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu238.bld RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters............
2 Building Information.....................
3 Source Information.......................
4 For time = O.0OE+O0 yr Time Specific Parameters..............
8 Receptor-Source Dose Summary..........
11 Dose by Pathway Detail................
12 Dose by Nuclide Detail................
13 For time = 1.OOE+00 yr Time Specific Parameters..............
15 Receptor-Source Dose Summary..........
18 Dose by Pathway Detail................
19 Dose by Nuclide Detail................
20 For time = 5.00E+00 yr Time Specific Parameters..............
22 Receptor-Source Dose Summary..........
25 Dose by Pathway Detail.................
26 Dose by Nuclide Detail................
27 Full Summary.............................
29 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:41:26 Page:
2 **
Title : Humboldt Bay DCGLPu238 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu238.bld RESRAD-BUILD Input Parameters Number of Sources 6
Number of Receptors:
1 Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information Receptor Room x
y z
FracTime Inhalation Ingestion(Dust)
[m]
[m]
[m]
[m3/day]
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 1.OOE-04
=
Receptor-Source Shielding Relationship
=
Receptor Source Densit Thickness Material
[g/cm3]
[cm]
1 1
1.00E+00 0.OE+-00 Concrete 1
2 1.00E+00 0.0OE+00 Concrete 1
3 1.OOE+00 0.OE+-00 Concrete 1
4 1.OOE+00 O.OOE+00 Concrete 1
5 1.OOE+00 O.OOE+00 Concrete 1
6 1.OOE+00 0.OOE+00 Concrete
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:41:26 Page:
3
- Title : Humboldt Bay DCGL_Pu238 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HBDCGL-Pu238.bld Building Information Building Air Exchange Rate: 8.36E-01 1/hr Height[m]
Air Exchanges [m3/hr]
Area [m2
<=QO1: 9.94E+01 Hi:
2.490 Room 1
Q10 :
9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 1.52E-05 [m/s]
Resuspension Rate: 1.79E-08 [1/s]
t9BARTLETT Page 87
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:41:26 Page:
4 **
Title : Humboldt Bay DCGLPu238 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu238.bld
=
Source Information Source:
1 Location::
Room :
1 X:
4.24 y:
2.82 z:
0.00[m]
Geometry::
Type: Area Length[m]:8.47E+O0 width[m]:5.64E+0O Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.825E+04 [day]
Radon Release Fraction:
1.O00E-01 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
Pu-238 1.OOOE+00 3.200E-03 3.920E-01 5.700E-07 u-234 O.OOOE+00 2.830E-04 1.320E-01 8.912E-07 TH-230 O.O00E+00 5.480E-04 3.260E-01 2.032E-06 RA-226 O.OOOE+O0 1.321E-03 8.594E-03 1.035E-02 PB-210 O.OO0E+O0 5.376E-03 1.380E-02 1.043E-05 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
1.25(m]
Geometry::
Type: Area Length[m]:8.47E+00 Width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.823E+04 [day]
Radon Release Fraction:
1.OOOE-01 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
Pu-238 1.OOOE+00 3.200E-03 3.920E-01 5.700E-07 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:41:26 Page:
5 **
Title : Humboldt Bay DCGL-Pu238 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu238.bld u-234 O.OOOE+00 2.830E-04 1.320E-01 8.912E-07 TH-230 O.OOOE+00. 5.480E-04 3.260E-01 2.032E-06 RA-226 O.OOOE+00 1.321E-03 8.594E-03 1.035E-02 PB-210 O.OOOE+00 5.376E-03 1.380E-02 1.043E-05 Source:
3 Location::
Room :
1 X:
0.00 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
1.813E+04 [day]
Radon Release Fraction:
1,OO0E-Ol Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
(mrem/pCi]
[mrem/yr/
(pCi/m3)]
Pu-238 1.OOOE+00 3.200E-03 3.920E-01 5.700E-07 u-234 0.000E+00 2.830E-04 1.320E-01 8.912E-07 TH-230 O.OOOE+00 5.480E-04 3.260E-01 2.032E-06 RA-226 O.OOOE+00 1.321E-03 8.594E-03 1.035E-02 PB-210 O.OOOE+00 5.376E-03 1.380E-02 1.043E-05 Source:
4 Location::
Room :
1 X:
4.24 y:
5.64 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 (i/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.O00E-01 Time to Remove:
1.821E+04 [day]
Radon Release Fraction:
1.O00E-01 f)SARTLETT Page 88 (1BARTLETT Page 88
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR'11)
Ingestion Inhalation Submersion
[pCi/m2)
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:41:26 Page:
6 *.
Title : Humboldt Bay DCGLPu238 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu238.bld Pu-238 1.OOOE+00 3.200E-03 3.920E-01 5.700E-07 u-234 O.OOOE+00 2.830E-04 1.320E-01 8.912E-07 TH-230 0.O00E+0O 5.480E-04 3.260E-01 2.032E-06 RA-226 O.OOOE+00 1.321E-03 8.594E-03 1.035E-02 PB-210 O.OOOE+O0 5.376E-03 1.380E-02 1.043E-05 Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.0OOE-01 Time to Remove:
1.809E+04 [day]
Radon Release Fraction:
1.OOGE-Ol Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
Pu-238 1.OOE+00 3.200E-03 3.920E-01 5.700E-07 u-234 O.O00E+0O 2.830E-04 1.320E-01 8.912E-07 TH-230 O.OOOE+0D 5.480E-04 3.260E-01 2.032E-06 RA-226 O.O00E+00 1.321E-03 8.594E-03 1.035E-02 PB-210 0.OOOE+00 5.376E-03 1.380E-02 1.043E-05
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:41:26 Page:
7
- Title : Humboldt Bay DCGLPu238 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HBDCGL-Pu238.bld Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.825E+04 [day]
Radon Release Fraction:
1.0OOE-01 Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
Pu-238 1.OOOE+00 3.200E-03 3.920E-01 5.700E-07 u-234 O.OO0E+0O 2.830E-04 1.320E-01 8.912E-07 TH-230 O.OOOE+00 5.480E-04 3.260E-01 2.032E-06 RA-226 O.OOOE+00 1.321E-03 8.594E-03 1.035E-02 PB-210 O.OOOE+00 5.376E-03 1.380E-02 1.043E-05
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:41:26 Page:
8 **
Title : Humboldt Bay DCGLPu238 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu238.bld Evaluation Time:
0.OOOOOOOOE+00 years Assessment for Time:
1 Time =0.OOE+00 yr
===========ý====... ---..
Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
Pu-238 1.OOOE+O0 u-234 0.OOOE+00 t&BARTLETT Page 89
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 TH-230 0.O00E+00 RA-226 O.OOOE+00 PB-210 O.O0OE+00 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
Geometry::
Type: Area Length[m]:8.47E+00 Pathway ::
Direct Ingestion Rate:
9.320E-07 (1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.00OE-01 Time to Remove:
1.823E+04 [day]
1.25 [m]
width[m]:2.49E+00 Direction: y Contamination::
Nuclide Concentration
[pCi/m2]
PU-238 1.OOOE+00 U-234 O.OOOE+00 TH-230 O.O00E+00 RA-226 O.000E+00 PB-210 O.O00E+00 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:41:26 Page:
9 **
Title : Humboldt Bay DCGLPu238 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu238.bld Evaluation Time:
0.00000000E+00 years Source:
3 Location::
Room :
1 x:
0.00 y:
2.82 z:
Geometry::
Type: Area Length[m]:5.64E+00 Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.813E+04 [day]
1.25 [m]
width[m]:2.49E+00 Direction: x Contamination::
Nuclide Concentration
[pCi/m2]
Pu-238 1.OOOE+00 u-234 0.000E+00 TH-230 O.OOOE+00 RA-226 O.OOOE+00 PB-210 O.OOOE+00 Source:
4 Location::
Room :
1 X:
4.24 y:
5.64 z:
Geometry::
Type: Area Length[m]:8.47E+00 Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
1.821E+04 [day]
1.25 [m]
width[m]:2.49E+00 Direction: y Contamination::
Nuclide Concentration
[pCi/m2]
PU-238 1.0OOE+00 U-234 O.O00E+00 7H-230 O.O00E+0O RA-226 O.OOOE+00 PB-210 O.OOOE+00 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:41:26 Page:
10 **
Title : Humboldt Bay DCGLPu238 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu238.bld Evaluation Time:
O.OO0OOOOOE+00 years Source:
5 Location::
Room :
1 x:
8.
Geometry::
Type: Area Pathway ::
Direct Ingestion Rate:
Fraction released to air:
Removable fraction:
Time to Remove:
47 y:
2.82 z:
1.25 [m]
Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x 9.320E-07 [1/hr]
7.OOOE-02 1.000E-01 1.809E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
PU-238 1.OOOE+O0 u-234 O.O00E+00 TH-230 0.O00E+O0 RA-226 O.OOOE+00 PB-210 0.00E+O0 Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+00 Width[m]:S.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.825E+04 [day]
teA RTL ETT Page 90 AMBART'ETT Page 90
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Contamination::
Nuclide Concentration
[pCi/m2]
PU-238 1.000E+00 u-234 O.O00E+00 TH-230 O.O00E+00 RA-226 O.OOOE+00 PB-210 O.OOOE+00
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:41:26 Page:
11 **
Title : Humboldt Bay DCGL.Pu238 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu238.bld Evaluation Time:
0.OOQOOOOOE+00 years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
4.62E-05 2.04E-05 1.36E-05 2.04E-05 1.36E-05 4.62E-05 1.60E-04 Total 4.62E-05 2.04E-05 1.36E-05 2.04E-05 1.36E-05 4.62E-05 1.60E-04 AMBARTLETT Page 91
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Pu-239 Results:
RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:44:48 Page:
1 4.
Title : Humboldt Bay DCGL_Pu239 Input File : C:\\RESRADFaMily\\BUILD\\3.S\\HBDCGL-Pu239.bld RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters............
2 Building Information.....................
3 Source Information.......................
4 For time = 0.OOE+00 yr Time Specific Parameters..............
7 Receptor-Source Dose Summary..........
10 Dose by Pathway Detail................
11 Dose by Nuclide Detail................
12 For time = 1.OOE+00 yr Time Specific Parameters..............
14 Receptor-Source Dose Summary..........
17 Dose by Pathway Detail................
18 Dose by Nuclide Detail................
19 For time = 5.0E+O00 yr Time Specific Parameters...............
21 Receptor-Source Dose Summary:..........
24 Dose by Pathway Detail................
25 Dose by Nuclide Detail................ 26 Full Summary.............................
28
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:44:48 Page:
2 **
Title : Humboldt Bay DCGLPu239 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HBDCGL-Pu239.bld RESRAD-BUILD Input Parameters Number of Sources 6
Number of Receptors:
1 Total Time
- 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information Receptor Room x
y z
FracTime Inhalation Ingestion(Dust)
[m]
[m]
[m]
[m3/day]
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 1.OOE-04
=*
Receptor-Source Shielding Relationship
=
Receptor Source Densit Thickness Material Recptr ouce
[g/cm3T cm 1
1 1.OOE+O0 O.00E+00 Concrete 1
2 1.OOE+O0 0.OOE+00 Concrete 1
3 1.00E+O0 0.OOE+00 Concrete 1
4 1.0OE+O0 O.OOE+O0 Concrete 1
5 1.OOE+O0
.OOOE+O0 Concrete 1
6 1.OOE+O0 O.OOE+00 Concrete RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:44:48 Page:
3 Title : Humboldt Bay DCGLPu239 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HBDCGL-Pu239.bld Building Information Building Air Exchange Rate: 8.36E-01 1/hr Height[m]
Air Exchanges [m3/hr]
Area [m 2]
c=QO1: 9.94E+01 Hi:
2.490 Room 1
Q10 :
9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 1.52E-05 [m/si Resuspension Rate: 1.79E-08 [1/s]
t)BARTLETT Page 92
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:44:48 Page:
4
- Title : Humboldt Bay DCGL.Pu239 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu239.bld Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[n]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.0OOE-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
Pu-239 1.OOOE+00 3.540E-03 4.290E-01 4.952E-07 u-235 O.OOOE+00 2.673E-04 1.230E-01 9.019E-04 PA-231 O.OOOE+00 1.060E-02 1.280E+00 2.009E-04 AC-227 0.000E+00 1.480E-02 6.724E+00 2.161E-03 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OO0E-01 Time to Remove:
1.823E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pci]
[mrem/yr/
(pCi/m3)]
Pu-239 1.000E+00 3.540E-03 4.290E-01 4.952E-07 u-235 O.000E+00 2.673E-04 1.230E-01 9.019E-04 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:44:48 Page:
5 **
Title : Humboldt Bay DCGLPu239 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HB_.DCGL-Pu239.bld PA-231 O.O00E+O0 1.060E-02 1.280E+00 2.009E-04 AC-227 O.000E+00 1.480E-02 6.724E+00 2.161E-03 Source:
3 Location::
Room :
1 x:
0.00 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
I.OOOE-01 Time to Remove:
1.813E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion-Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
Pu-239 1.O00E+00 3.540E-03 4.290E-01 4.952E-07 u-235 O.OOOE+00 2.673E-04 1.230E-01 9.019E-04 PA-231 O.000E+00 1.060E-02 1.280E+00 2.009E-04 AC-227 O.O000E+0 1.480E-02 6.724E+00 2.161E-03 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.821E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
Pu-239 1.OO0E+00 3.540E-03 4.290E-01 4.952E-07 u-235 O.O00E+00 2.673E-04 1.230E-01 9.019E-04 PA-231 O.OO0E+00 1.060E-02 1.280E+00 2.009E-04
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:44:48 Page:
6
- Title : Humboldt Bay DCGLPu239 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu239.bld AC-227 0.000E+00 1.480E-02 6.724E+00 2.161E-03 Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
teARTLETT Page 93
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
1.809E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
Pu-239 1.000E+00 u-235 0.000E+00 PA-231 0.OOOE+00 AC-227 O.OOOE+00 Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
3.540E-03 4.290E-01 4.952E-07 2.673E-04 1.230E-01 9.019E-04 1.060E-02 1.280E+00 2.009E-04 1.480E-02 6.724E+00 2.161E-03 Source:
6 Location::
Room :
1 X:
4..
Geometry::
Type: Area Pathway ::
Direct Ingestion Rate:
Fraction released to air:
Removable fraction:
Time to Remove:
24 y:
2.82 z:
2.49[m]
Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z 9.320E-07 [1/hr]
7.O00E-02 1.000E-01 1.825E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
PU-239 1.OO0E+00 3.540E-03 4.290E-01 4.952E-07 u-235 O.OOOE+00 2.673E-04 1.230E-01 9.019E-04 PA-231 O.O00E+00 1.060E-02 1.280E+00 2.009E-04 AC-227 O.O00E+00 1.480E-02 6.724E+00 2.161E-03 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:44:48 Page:
Title : Humboldt Bay DCGLPu239 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HB.DCGL-Pu239.bld Evaluation Time:
O.O0000OOOE+00 years 7 **
=
Assessment for Time:
1 Time =O.OE+O00 yr Source Information Source:
I Location::
Room :
1 X:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air:
7.O00E-02 Removable fraction:
1.O00OE-01 Time to Remove:
.1.825E+04 [day]
Contamination::
Nuclide Pu-239 u-235 PA-231 AC-227 Concentration
[pCi/m2]
1.O00E+00 0.0OOE+0O 0.000E+00 O.00OE+0O Source:
2 Location::
Room :
1 X:
4.24 y:
0.00 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 widtb[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.823E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
Pu-239 1.OOOE+00 u-235 O.OOOE+00 PA-231 O.OOOE+00 AC-227 0O00E+O0
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:44:48 Page:
8 **
Title : Humboldt Bay DCGLPu239 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu239.bld Evaluation Time:
O.OOOOOOOOE+00 years Source:
3 Location::
Room :
1 x:
Geometry::
Type: Area Pathway ::
Direct Ingestion Rate:
Fraction released to a Removable fraction:
Time to Remove:
Contamination::
Nuclid Pu-239 U-235 PA-231 AC-227 0.00 y:
2.82 z:
1.25 [m]
Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x 9.320E-07 [1/br]
ir: 7.OOOE-02 1.O0OE-01 1.813E+04 [day]
Concentration
[pci/m2]
1.0OOE+0O O.O0OE+00 0.OOOE+00 0.OOOE+00 t BA RRT L ETT Page 94
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.O00E-01 Time to Remove:
1.821E+04 [day]
Contamination::
Nuclide Concentration
[pci/m2]
PU-239 1.OOOE+OO u-235 O.O00OE+0O PA-231 O.OOOE+OO AC-227 O.OOOE+OO
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:44:48 Page:
9 **
Title : Humboldt Bay DCGLPu239 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu239.bld Evaluation Time:
O.OOOOOOOOE+00 years Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+O0 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.809E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
Pu-239 1.OO0E+OO u-235 O.OOOE+00 PA-231 O.OOOE+00 AC-227 O.OOOE+00 Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
Pu-239 1.OOOE+00 u-235 O.000E+OO PA-231 0.OOOE+0O AC-227 O.OOOE+0O RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:44:48 Page:
10
- Title : Humboldt Bay DCGL_Pu239 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu239.bld Evaluation Time:
0.00000000E+00 years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
5.11E-05 2.26E-05 1.51E-05 2.26E-05 1.51E-05 5.11E-05 1.78E-04 Total 5.11E-0S 2.26E-05 1.51E-05 2.26E-05 1.S1E-OS 5.11E-O5 1.78E-04
/t) SART L cr Page 95
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Pu-240 Results:
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:48:07 Page:
1 **
Title
- Humboldt Bay DCGLPu240 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu240;bld RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters............
2 Building Information.....................
3 Source Information.......................
4 For time = 0.OOE+O0 yr Time Specific Parameters..............
8 Receptor-Source Dose Summary..........
11 Dose by Pathway Detail................
12 Dose by Nuclide Detail................
13 For time = 1.OOE+00 yr Time Specific Parameters..............
15 Receptor-Source Dose Summary..........
18 Dose by Pathway Detail................
19 Dose by Nuclide Detail................
20 For time = 5.OOE+00 yr Time Specific Parameters..............
22 Receptor-Source Dose Summary..........
25 Dose by Pathway Detail................
26 Dose by Nuclide Detail................
27 Full Summary.............................
29
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:48:07 Page:
2 **
Title
- Humboldt Bay DCGL_Pu240 Input File : C:\\RESRADFamily\\BUILo\\3.5\\HBDCGL-Pu240.bld RESRAD-BUILD Input Parameters Number of Sources 6
Number of Receptors:
1 Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information Receptor Room x
y z
FracTime Inhalation Ingestion(Dust)
[m]
[m]
[m)
[m3/day]
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 1.OOE-04 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material Eg/cm3T
[cm]e 1
1 1.OOE+00 0.OOE+00 Concrete 1
2 1.OOE+00 0.OOE+00 Concrete 1
3 1.OOE+00 0.00E+00 Concrete 1
4 1.OOE+00 0.OOE+00 Concrete 1
5 1.0OE+00 0.OOE+00 Concrete 1
6 1.OOE+00 0.00E+O0 Concrete RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:48:07 Page:
3 Title
- Humboldt Bay DCGL_Pu240 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu240.bld Building Information Building Air Exchange Rate: 8.36E-01 1/hr Height[m]
Air Exchanges
[m3/hr]
Area [m2]
c=*QO1:9.94E+01 HI:
2.490 Room 1
Q1O :
9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 1.52E-05 [m/s]
Resuspension Rate: 1.79E-08 [l/s]
(
BARTLETT Page 96
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:48:07 Page:
4 **
Title : Humboldt Bay DCGL-Pu240 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu240.bld
==
Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.0008-02 Removable fraction:
1.0O0E-01 Time to Remove:
1.825E+04 [day]
Radon Release Fraction:
1.000E-01 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
(mrem/yr/
(pCi/m3)]
Pu-240 1.000E+00 3.540E-03 4.290E-01 5.548E-07 u-236 O.O00E+00 2.690E-04 1.250E-01 5.852E-07 TH-232 O.O00E+00 2.730E-03 1.640E+00 1.018E-06 TH-228 O.OOOE+00 8.086E-04 3.454E-01 9.378E-03 RA-228 0.000E+0O 1.442E-03 5.078E-03 5.583E-03 Source:
2 Location::
Room :
1 X:
4.24 y:
0.00 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.823E+04 [day]
Radon Release Fraction:
1.OOOE-01 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
Pu-240 1.OOOE+00 3.540E-03 4.290E-01 5.548E-07
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:48:07 Page:
5 **
Title : Humboldt Bay DCGLPu240 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu240.bld u-236 O.00E+00 2.690E-04 1.250E-01 5.852E-07 TH-232 O.OOOE+00 2.730E-03 1.640E+00 1.018E-06 TH-228 O.OOOE+00 8.086E-04 3.454E-01 9.378E-03 RA-228 O.O00E+00 1.442E-03 5.078E-03 5.583E-03 Source:
3 Location::
Room :
1 x:
0.00 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.813E+04 [day]
Radon Release Fraction:
1.OOOE-01 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
PU-240 1.OOOE+00 3.540E-03 4.290E-01 5.548E-07 u-236 O.OOOE+00 2.690E-04 1.250E-01 5.852E-07 TH-232 0.OOOE+00 2.730E-03 1.640E+00 1.018E-06 TH-228 O.O00E+00 8.086E-04 3.454E-01 9.378E-03 RA-228 O.OOOE+00 1.442E-03 5.078E-03 5.583E-03 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
1.821E+04 [day]
Radon Release Fraction:
1.0O0E-01 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:48:07 Page:
6 Title : Humboldt Bay DCGLPu240 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu240.bld t
BARTLETT Page 97
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Pu-240 1.OOOE+00 3.540E-03 4.290E-01 5.548E-07 u-236 0.000E+00 2.690E-04 1.250E-01 5.852E-07 TH-232 0.OOOE+00 2.730E-03 1.640E+00 1.018E-06 TH-228 0.000E+00 8.086E-04 3.454E-01 9.378E-03 RA-228 OO008E+00 1.442E-03 5.078E-03 5.583E-03 Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 widthEm]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.00E-01 Time to Remove:
1.809E+04 [day]
Radon Release Fraction:
1.000E-01 Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
Pu-240 1.000E+O0 3.540E-03 4.290E-01 5.548E-07 u-236 O.OOOE+00 2.690E-04 1.250E-01 5.852E-07 TH-232 0.000E+O0 2.730E-03 1.640E+00 1.018E-06 TH-228 O.OOOE+00 8.086E-04 3.454E-01 9.378E-03 RA-228 O.OOOE+00 1.442E-03 5.078E-03 5.583E-03
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:48:07 Page:
7
- Title : Humboldt Bay DCGLPu240 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu240.bld Source:
6Location::
Room :
I x:
4.24 y:
2.82 z:
2.49[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.O00E-02 Removable fraction:
1.000E-01 Time to Remove:
1.825E+04 [day]
Radon Release Fraction:
1.OOOE-01 Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
Pu-240 1.00OE+O0 3.540E-03 4.290E-01 5.548E-07 u-236 0.O0OE+00 2.690E-04 1.250E-01 5.852E-07 TH-232 0.00OE+00 2.730E-03 1.640E+00 1.018E-06 TH-228 0.000E+00 8.086E-04 3.454E-01 9.378E-03 RA-228 O.OOOE+00 1.442E-03 5.078E-03 5.583E-03
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:48:07 Page:
8 **
Title : Humboldt Bay DCGLPu240 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu240.bld Evaluation Time:
O.00000000E+00 years Assessment for Time:
1 Time =O.OOE+00 yr Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.O00E-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
Pu-240 1.OOOE+00 u-236 0.OOOE+00 TH-232 0.OOOE+00 TH-228 0.OOOE+00 RA-228 0.OOOE+00 Source:
2 Location::
Room :
1 X:
4.24 y:
0.00 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.823E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
Pu-240 1.000E+00 u-236 O.O00E+00 TH-232 O.O00E+00 TH-228 O.000E+00 RA-228 0.000E+00 t
BARTLETT Page 98
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:48:07 Page:
9 Title : Humboldt Bay DCGLPu240 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu240.bld Evaluation Time:
O.OOOOOOOOE+00 years Source:
3 Location::
Room :
1 X:
0.00 y:
2.82 z:
1.25 (m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.813E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
Pu-240 1.0OOE+0O u-236 O.OO0E+00 TH-232 O.O00E+00 TH-228 0.OOOE+00 RA-228 0.OOOE+00 source:
4 Location::
Room :
1 X:
4.24 y:
5.64 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.821E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
PU-240 1.O00E+00 u-236 O.O00E+00 TH-232 O.000E+00 TH-228 O.O00E+00 RA-228 O.000E+00 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:48:07 Page:
10 **
Title : Humboldt Bay DCGLPu240 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu240.bld Evaluation Time:
O.O00OOO0OE+O0 years Source:
5 Location::
Room :
Geometry::
Type: Ar Pathway ::
Direct Ingestion Fraction releas Removable fract Time to Remove:
Contamination::
I x:
8.47 y:
2.82 z:
1.25 [m]
ea Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x n Rate:
9.320E-07 [1/hr]
ed to air: 7.OOOE-02 ion:
1.OOOE-01 1.809E+04 [day]
Nuclide concentration
[pCi/m2]
Pu-240 1.000E+00 u-236 O.OOOE+00 TH-232 O.OOOE+00 TH-228 0.O00OE+00 RA-228 O.OOOE+00 Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
Pu-240 1.000E+00 u-236 O,0OOE+00 TH-232 O.00E+00 TH-228 0.0OOE+00 RA-228 O.OOOE+00
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:48:07 Page:
11
- Title : Humboldt Bay DCGL-Pu240 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu240.bld Evaluation Time:
O.O000000E+O0 years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
5.11E-05 2.26E-05 1.51E-05 2.26E-05 1.51E-05 5.11E-05 1.78E-04 Total 5.11E-05 2.26E-05 1.51E-05 2.26E-05 1.S1E-05 5.11E-05 1.78E-04 (fBARTLETT Page 99
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Pu-241 Results:
RESRAD-BUILD.Dose Program Output, Version 3.50 01/25/12 10:51:42 Page:
I **
Title : Humboldt Bay DCGL_Pu241 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu241.bld RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters............
2 Building Information.....................
3 Source Information.......................
4 For time = O.OOE+00 yr Time Specific Parameters..............
8 Receptor-Source Dose Summary..........
11 Dose by Pathway Detail................
12 Dose by Nuclide Detail................
13 For time = 1.00E+00 yr Time Specific Parameters..............
15 Receptor-Source Dose Summary..........
18 Dose by Pathway Detail................
19 Dose by Nuclide Detail................
20 For time = 5.00E+00 yr Time Specific Parameters..............
22 Receptor-Source Dose Summary..........
25 Dose by Pathway Detail................
26 Dose by Nuclide Detail................
27 For time = 1.00E+01 yr Time Specific Parameters..............
29 Receptor-Source Dose Summary..........
32 Dose by Pathway Detail................
33 Dose by Nuclide Detail................
34 For time = 2.50E+01 yr Time Specific Parameters..............
36 Receptor-Source Dose Summary..........
39 Dose by Pathway Detail................
40 Dose by Nuclide Detail................
41 For time = 5.OOE+01 yr Time Specific Parameters..............
43 Receptor-Source Dose Summary..........
46 Dose by Pathway Detail................
47 Dose by Nuclide Detail................
48 For time = 1.OOE+02 yr Time Specific Parameters..............
50 Receptor-Source Dose Summary..........
53 Dose by Pathway Detail................
54 Dose by Nuclide Detail................
55 Full Summary.............................
57
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:51:42 Page:
2
- Title : Humboldt Bay DCGLPu241 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu241.bld RESRAD-BUILD Input Parameters Number of Sources 6
Number of Receptors:
1 Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information Receptor Room x
y z
FracTime Inhalation Ingestion(Dust)
[m]
[m]
[m]
[m3/dayJ
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 1.00E-04
=-
Receptor-Source Shielding Relationship Receptor Source Densit Thickness Material g/mT [cm]
1 1
1.00E+O0 O.OOE+00 Concrete 1
2 1.00E+00 O.OOE+00 Concrete 1
3 1.OOE+00 O.OOE+00 Concrete 1
4 1.0OE+O0 O.OOE+00 Concrete 1
5 1.00E+00 O.OOE+00 Concrete 1
6 1.00E+00 0.00E+00 Concrete
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:51:42 Page:
3
- Title : Humboldt Bay DCGI_Pu241 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu241.bld
-- Building Information tWBARTLETT Page 100
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Building Air Exchange Rate: 8.36E-01 i/hr Height[m]
Air Exchanges [m3/hr]
Area [m2]
<=QO1: 9.94E+01 HI:
2.490 Room 1
Q10 :
9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 1.52E-05 [m/s]
Resuspension Rate: 1.79E-08 [1/s]
RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:51:42 Page:
4 **
Title : Humboldt Bay DCGLPu241 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu241.bld Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration Dose conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
PU-241 1.OOOE+00 6.840E-05 8.250E-03 2.555E-08 AM-241 O.OOOE+00 3.640E-03 4.440E-01 9.554E-05 NP-237 O.OOOE+00 4.444E-03 5.400E-01 1.212E-03 u-233 O.OOOE+00 2.89OE-04 1.350E-01 1.904E-06 TH-229 0.OOOE+00 4.027E-03 2.169E+00 1.741E-03 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.823E+04 [day]
Contamination::
Nuclide concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCiJ
[mrem/yr/
(pCi/m3)]
PU-241 1.000E+00 6.840E-05 8.250E-03 2.555E-08 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:51:42 Page:
5 **
Title : Humboldt Bay DCGLPu241 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu241.bld AM-241 0.000E+00 3.640E-03 4.440E-01 9.554E-05 NP-237 0.00OE+00 4.444E-03 5.400E-01 1.212E-03 u-233 0.OOOE+00 2.890E-04 1.350E-01 1.904E-06 TH-229 0.000E-00 4.027E-03 2.169E+00 1.741E-03 Source:
3 Location::
Room :
1 X:
0.00 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.813E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
PU-241 1.000E+00 6.840E-05 8.250E-03 2.555E-08 AM-241 O.OOOE+00 3.640E-03 4.440E-01 9.554E-05 NP-237 0.OOOE+00 4.444E-03 5.400E-01 1.212E-03 U-233 0.OOOE+00 2.890E-04 1.350E-01 1.904E-06 TH-229 0.O00E+00 4.027E-03 2.169E+00 1.741E-03 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.821E+04 [day]
t BARTLETT Page 101
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Contami nation::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:51:42 Page:
6 **
Title : Humboldt Bay DCGL.Pu241 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HBDCGL-Pu241.bld Pu-241 1.OOOE+00 6.840E-05 8.250E-03 2.555E-08 AM-241 0.000E+O0 3.640E-03 4.440E-01 9.554E-05 NP-237 O.000E+00 4.444E-03 5.400E-01 1.212E-03 u-233 O.OOOE+00 2.890E-04 1.350E-01 1.904E-06 TH-229 O.OOOE+00 4.027E-03 2.169E+00 1.741E-03 Source:
5 Location::
Room :
I x:
8.47 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
LOO0E-01 Time to Remove:
1.809E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
Pu-241 1.OOOE+00 6.840E-05 8.250E-03 2.555E-08 AM-241 O.OOOE+00 3.640E-03 4.440E-01 9.554E-05 NP-237 O.OOOE+00 4.444E-03 5.400E-01 1.212E-03 u-233 O.OOOE+00 2.890E-04 1.350E-01 1.904E-06 TH-229 O.OOOE+00 4.027E-03 2.169E+00 1.741E-03 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:51:42 Page:
7 **
Title : Humboldt Bay DCGLPu241 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu241.bld Source:
6 Location::
Room :
I X:
4.24 y:
2.82 z:
2.49[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway :
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.00OE-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
Pu-241 1.O0E+O0 6.840E-05 8.250E-03 2.555E-08 Am-241 O.000E+00 3.640E-03 4.440E-01 9.554E-05 NP-237 0.OO0E+00 4.444E-03 5.400E-01 1.212E-03 u-233 O.OOOE+00 2.890E-04 1.350E-01 1.904E-06 TH-229 O.OOOE+00 4.027E-03 2.169E+00 1.741E-03
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:51:42 Page:
8 **
Title : Humboldt Bay DCGLPu241 Input File : C:\\RESRADoFamily\\BUILD\\3.5\\HBDCGL-Pu241.bld Evaluation Time:
0.00000000E+00 years Assessment for Time:
1 Time =0.0OE+00 yr Source Information Source:
1 Location::
Room :
1 X:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr)
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
Pu-241 1.OOOE+00 AM-241 O.OOOE+00 NP-237 0.OOOE+00 u-233 0.OOOE+00 TH-229 0.OOOE+00 Source:
2 Location::
Room :
1 X:
4.24 y:
0.00 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.823E+04 [day]
f)BARTLETT Page 102
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0 Contamination::
Nuclide Concentration
[pCi/m2]
Pu-241 1.000E+00 AM-241 0.000E+00 NP-237 O.000E+00 u-233 O.000E+00 TH-229 O.000E+00
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:51:42 Page:
9 **
Title : Humboldt Bay DCGL.Pu241 Input File : C:\\RESRAD-Family\\BUILD\\3.5\\HBDCGL-Pu241.bld Evaluation Time:
O.O0000000E+00 years Source:
3 Location::
Room :
1 x:
0.00 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 Width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 (1/br]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
1.813E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
Pu-241 1.000E+00 Am-241 O.000E+00 NP-237 O.000E+00 u-233 O.000E+00 TH-229 O.000E+00 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.OOE-O1 Time to Remove:
1.821E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
Pu-241 1.O00E+00 AM-241 0.O00E+00 NP-237 0.O00E+00 u-233 0.O00E+00 TH-229 O.O00E+00
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:51:42 Page:
10
- Title : Humboldt Bay DCGLPu241 Input File : C:\\RESRAD_.Family\\BUILD\\3.5\\HBDCGL-pu241.bld Evaluation Time:
0.O0000000E÷00 years Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
1.809E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
Pu-241 1.0000E+0 Am-241 0.0OE+O0 NP-237 0.000E+00 u-233 0.OOOE+00 TH-229 0.OO0E+00 Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.0OOE-02 Removable fraction:
1.000E-01 Time to Remove:
1.825E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
Pu-241 1.000E+00 AM-241 O.O00E+00 NP-237 O.O00E+00 u-233 O.000E+00 TH-229 O.O00E+00 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:51:42 Page:
11
- Title : Humboldt Bay DCGLPu241 Input File : C:\\RESRADOFamily\\BUILD\\3.5\\HBDCGL-Pu241.bld Evaluation Time:
O.O0000000E+00 years RESRAD-BUILD Dose Tables
=-
CB DART L-ETT Page 103
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
1.OOE-06 4.44E-07 2.96E-07 4.44E-07 2.96E-07 1.OOE-06 3.49E-06 Total 1.OOE-06 4.44E-07 2.96E-07 4.44E-07 2.96E-07 1.00E-06 3.49E-06
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:51:42 Page:
18
- Title : Humboldt Bay DCGLPu241 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu241.bld Evaluation Time:
1.00000000 years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[trem)
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
1.03E-06 4.53E-07 3.02E-07 4.53E-07 3.02E-07 1.03E-06 3.56E-06 Total 1.03E-06 4.53E-07 3.02E-07 4.53E-07 3.02E-07 1.03E-06 3.56E-06
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:51:42 Page:
25 **
Title : Humboldt Bay DCGLPu241 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu241.bld Evaluation Time:
5.00000000 years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
1.08E-06 4.77E-07 3.18E-07 4.77E-07 3.18E-07 1.08E-06 3.75E-06 Total 1.08E-06 4.77E-07 3.18E-07 4.77E-07 3.18E-07 1.08E-06 3.75E-06
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:51:42 Page:
32 **
Title : Humboldt Bay DCGLPu241 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu241.bld Evaluation Time:
10.0000000 years
==
==
======--...
==
RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 S
6 Receptor 1
1.1OE-06 4.86E-07 3.24E-07 4.87E-07 3.24E-07 1.1OE-06 3.83E-06 Total 1.1OE-06 4.86E-07 3.24E-07 4.87E-07 3.24E-07 1.10E-06 3.83E-06
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:51:42 Page:
39 **
Title : Humboldt Bay DCGL._Pu241 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Pu241.bld Evaluation Time:
25.0000019 years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
9.67E-07 4.25E-07 2.83E-07 4.25E-07 2.82E-07 9.65E-07 3.35E-06 Total 9.67E-07 4.25E-07 2.83E-07 4.25E-07 2.82E-07 9.65E-07 3.35E-06 tfBARTLETT Page 104
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Sr-90 Results:
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:59:26 Page:
1 **
Title : Humboldt Bay DCGLSr9O Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Sr90.bld RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters............
2 Building Information.....................
3 Source Information.......................
4 For time = O.OOE+00 yr Time Specific Parameters..............
7 Receptor-Source Dose Summary..........
10 Dose by Pathway Detail................
11 Dose by Nuclide Detail................
12 For time = 1.00E+0O yr Time Specific Parameters..............
14 Receptor-Source Dose Summary..........
17 Dose by Pathway Detail................
18 Dose by Nuclide Detail................
19 For time = 5.OOE+00 yr Time Specific Parameters..............
21 Receptor-Source Dose Summary..........
24 Dose by Pathway Detail................
25 Dose by Nuclide Detail................
26 Full Summary.............................
28 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:59:26 Page:
2
- Title : Humboldt Bay DCGL.Sr90 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Sr90.bld RESRAD-BUILD Input Parameters Number of Sources 6
Number of Receptors:
1 Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information Receptor Room x
y z
FracTime Inhalation Ingestion(Dust)
[m]
[m]
[im]
[m3/day]
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 1.OOE-04
=
Receptor-Source Shielding Relationship
=
Receptor Source DensitT Thickness Material 1g/cm31
.cm 1
2 1.00E+00 0.00E+O0 Concrete 1
2 1.OOE+00 O.OOE+00 Concrete 1
3 1.OOE+00 O.OOE+00 Concrete 1
5 1.OOE+00 O.OOE+00 Concrete 1
S 1.OOE+0O O.OOE+00 Concrete 1
6 I.OOE+O0 O.OOE+O0 Concrete RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:59:26 Page:
3 **
Title : Humboldt Bay DCGL_Sr90 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Sr90.bld Building Information Building Air Exchange Rate: 8.36E-01 1/hr Height[m]
Air Exchanges [m3/hr]
Area [m2]
=<QOI: 9.94E+01 Hl:
2.490 Room 1
Q10 :
9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 4.78E-04 [M/s]
Resuspension Rate: 6.70E-10 [1/s]
tl)
BARTL ETT Page 105
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:59:26 Page:
4 **
Title : Humboldt Bay DCGL-Sr90 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Sr90.bld Source Information Source:
1 Location::
Room :
1 X:
4.24 y:
2.82 Z:
0.00[m]
Geometry::
Type: Area Length[m]:8.47E+00 width Inm]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
3.306E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
SR-90 1.000E+00 1.528E-04 1.308E-03 2.307E-05 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
3.320E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
SR-90 1.O00E+00 1.528E-04 1.308E-03 2.307E-05
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:59:26 Page:
5 **
Title : Humboldt Bay DCGLSr90 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Sr9O.bld Source:
3 Location::
Room :
1 x:
0.00 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:S.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
3.305E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCiJ
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
SR-90 1.000E+00 1.528E-04 1.308E-03 2.307E-05 Source:
4 Location::
Room :
1 x:
4.24 y:
5.64 z:
1.25[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
3.304E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
SR-90 1.000E+00 1.528E-04 1.308E-03 2.307E-05
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:59:26 Page:
6 **
Title : Humboldt Bay DCGLSr90 Input File : C:\\R8SRADFamily\\BUILD\\3.5\\HBDCGL-sr90.bld Source:
5 L'ocation::
Room :
1 X:
8.47 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:S.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
3.311E+04 [day]
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
SR-9O 1.OOOE+00 1.528E-04 1.308E-03 2.307E-05 Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[i]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
3.305E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
SR-90 1.000E+00 1.528E-04 1.308E-03 2.307E-05 RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:59:26 Page:
7 **
Title : Humboldt Bay DCGL-Sr9O Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Sr9O.bld Evaluation Time:
O.OOOOOOOOE+00 years Assessment for Time:
1 Time =O.OOE+00 yr
- =
ý= --==
Source Information Source:
1 Location::
Room :
1 X:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
3.306E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
SR-g0 1.000E+00 Source:
2 Location::
Room :
1 x:
4.24 y:
0.00 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.O00E-01 Time to Remove:
3.320E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2J SR-90 1.000E+00 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:59:26 Page:
8 **
Title : Humboldt Bay DCGL-Sr90 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Sr90.bld Evaluation Time:
0.00000000E+00 years Source:
3 Location::
Room :
1 x:
0.00 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.OOOE-01 Time to Remove:
3.305E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
SR-90 1.000E+00 Source:
4 Location::
Room :
1 X:
4.24 y:
5.64 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hrJ Fraction released to air: 7.OOOE-02
't1BARTLETT Page 107
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Removable fraction:
1.OOOE-Q1 Time to Remove:
3.304E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
SR-90 1.O00E+OO Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+O0 width[m]:2.49E+O0 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
3.311E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
SR-90 1.00OE+0O RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 10:59:26 Page:
9
- Title : Humboldt Bay DCGLSr90 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Sr90.bld Evaluation Time:
O.OOOOOOOOE+O0 years Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+O0 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.0OOE-01 Time to Remove:
3.305E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
SR-90 1.000E+O0
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 10:59:26 Page:
10 **
Title : Humboldt Bay DCGLSr90 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Sr9O.bld Evaluation Time:
.. 00000000E+00 years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
1.66E-06 7.22E-07 4.78E-07 7.22E-07 4.78E-07 1.65E-06 5.71E-06 Total 1.66E-06 7.22E-07 4.78E-07 7.22E-07 4.78E-07 1.65E-06 5.71E-06 4BARTLETT Page 108
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Tc-99 Results:
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 11:00:53 Page:
1 **
Title
- Humboldt Bay DCGLTC99 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-TC99.bld RESRAD-BUILD Table of Contents RESRAD-BUILD Input Parameters............
.2 Building Information.....................
'3 Source Information.......................
4 For time = O.0OE+00 yr Time Specific Parameters..............
7 Receptor-Source Dose Summary..........
10 Dose by Pathway Detail................
11 Dose by Nuclide Detail................
12 For time = 1.OOE+00 yr Time Specific Parameters..............
14 Receptor-Source Dose Summary...........
17 Dose by Pathway Detail.................
18 Dose by Nuclide Detail................
19 For time = 5.00E+00 yr Time Specific Parameters..............
21 Receptor-Source Dose Summary..........
24 Dose by Pathway Detail................
25 Dose by Nuclide Detail................
26 Full Summary.............................
28 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 11:00:53 Page:
2 **
Title
- Humboldt Bay DCGL_Tc99 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-TC99.bld RE'SRAD-BUILD Input Parameters Number of Sources 6
Number of Receptors:
1 Total Time 3.650000E+02 days Fraction Inside 2.670000E-01 Receptor Information
=
Receptor Room x
y z
FracTime Inhalation Ingestion(Dust)
[m]
[m]
[m]
[m3/day]
[m2/hr]
1 1
4.240 2.820 1.000 1.000 4.56E+01 1.OOE-04
=
Receptor-Source Shielding Relationship
=
Receptor Source Densit Thickness Material
[g/cm3ý
[cm]
1 1
1.OOE+00 O.OOE+0O Concrete 1
2 1.OOE+0O O.OOE+0O Concrete 1
3 1.OOE+00 O.OOE+0O Concrete 1
4 1.OOE+00 O.OOE+00 Concrete 1
5 1.OOE+00 O.OOE+00 Concrete 1
6 1.OOE+0O O.OOE+00 Concrete RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 11:00:53 Page:
3
- Title
- Humboldt Bay DCGLTc99 Input File
- C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-TC99.bld Building Information Building Air Exchange Rate: 8.36E-01 1/hr Height[m]
Air Exchanges [m3/hr]
<=QO1: 9.94E+01 Hi:
2.490 Room 1
Q10 :
9.94E+01 LAMBDA: 8.36E-01 Area 47.770 Deposition velocity: 4.78E-04 [m/s]
Resuspension Rate: 6.70E-10 [I/s]
IdMBARTLETT Page 109
Bartlett Engineering Humboldt Bay Building Surface DCGLs ENG-HB-004 Rev. 0
- RESRAD-BUILD Dose Program Output, version 3.50 01/25/12 11:00:53 Page:
4 **
Title : Humboldt Bay DCGLTc99 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Tc99.bld Source Information Source:
1 Location::
Room :
1 x:
4.
Geometry::
Type: Area Pathway ::
Direct Ingestion Rate:
Fraction released to air:
Removable fraction:
Time to Remove:
24 y:
2.82 z:
0.00[m]
Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z 9.320E-07 [1/hr]
7.000E-02 1.000E-01 3.306E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
TC-99 1.000E+00 1.460E-06 8.320E-06 1.892E-07 Source:
2 Location::
Room :
1 x:
4.
Geometry::
Type: Area Pathway ::
Direct Ingestion Rate:
Fraction released to air:
Removable fraction:
Time to Remove:
24 y:
0.00 z:
1.25[m]
Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y 9.320E-07 [1/hr]
7.000E-02 1.000E-01 3.320E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
TC-99 1.000E+00 1.460E-06 8.320E-06 1.892E-07 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 11:00:53 Page:
Title : Humboldt Bay DCGLTc99 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HB.DCGL-TC99.bld 5 **
Source:
3 Location::
Room :
1 x:
0.00 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pci/m3)]
TC-99 1.O00E+00 1.460E-06 8.320E-06 1.892E-07 Source:
4 Location::
Room :
1 x:
Geometry::
Type: Area Pathway ::
Direct Ingestion Rate:
Fraction released to ai Removable fraction:
Time to Remove:
4.24 y:
5.64 z:
1.25[m]
Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y 9.320E-07 [1/hr]
ir: 7.000E-02 1.OOOE-Ol 5.273E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pci/m3)]
TC-99 1.O00E+00 1.460E-06 8.320E-06 1.892E-07
- RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 11:00:53 Page:
6 **
Title : Humboldt Bay DCGLTc99 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-Tc99.bld Source:
5 Location::
Room :
1 x:
8.47 y:
2.82 z:
1.25[m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.OOOE-01 Time to Remove:
5.271E+04 [day]
(MBARTLETT Page 110
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2J (mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
TC-99 1.O00E+00 1.460E-06 8.320E-06 1.892E-07 Source:
6 Location::
Room :
I x:
4.24 y:
2.82 z:
2.49[m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.OOOE-01 Time to Remove:
3.305E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library: FGR 11)
Ingestion Inhalation Submersion
[pCi/m2]
[mrem/pCi]
[mrem/pCi]
[mrem/yr/
(pCi/m3)]
TC-99 1.OOOE+0O 1.460E-06 8.320E-06 1.892E-07 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 11:00:53 Page:
7 **
Title : Humboldt Bay DCGLTc99 Input File : C:\\RESRADFamily\\BUILD\\3.S\\HB.DCGL-TC99.bld Evaluation Time:
0.OOOOOOOOE+O0 years Assessment for Time:
1 Time =O.OOE+00 yr Source Information Source:
1 Location::
Room :
1 x:
4.24 y:
2.82 z:
0.00 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:S.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
3.306E+04 [day]
Contamination::
Nuclide Concentration (pCi/m2]
TC-99 1.000E+00 Source:
2 Location::
Room :
I X:
4.24 y:
0.00 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.OOOE-02 Removable fraction:
1.000E-01 Time to Remove:
3.320E+04 (day]
Contamination::
Nuclide Concentration
[pCi/m2]
TC-99 1.000E+00 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 11:00:53 Page:
8 *0 Title : Humboldt Bay DCGL-TC99 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-TC99.bld Evaluation Time:
0.00000000E+00 years Source:
3 Location::
Room :
I X:
0.00 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
5.278E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
TC-99 1.OOOE+00 Source:
4 Location::
Room :
1 X:
4.24 y:
5.64 z:
1.25 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:2.49E+00 Direction: y Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.000E-01 r BARTLETT Page 111
Bartlett Engineering ENG-HB-004 Humboldt Bay Building Surface DCGLs Rev. 0 Time to Remove:
5.273E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
TC-99 1.00OE+00 Source:
5 Location::
Room :
1 X:
8.47 y:
2.82 z:
1.25 [m]
Geometry::
Type: Area Length[m]:5.64E+00 width[m]:2.49E+00 Direction: x Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction:
1.OOOE-01 Time to Remove:
5.271E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
TC-99 1.000E+00 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 11:00:53 Page:
9 Title : Humboldt Bay DCGLTc99 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HB_DCGL-Tc99.bld Evaluation Time:
0.00OO0000E+00 years Source:
6 Location::
Room :
1 x:
4.24 y:
2.82 z:
2.49 [m]
Geometry::
Type: Area Length[m]:8.47E+00 width[m]:5.64E+00 Direction: z Pathway ::
Direct Ingestion Rate:
9.320E-07 [1/hr]
FPaction released to air: 7.000E-02 Removable fraction:
1.000E-01 Time to Remove:
3.305E+04 [day]
Contamination::
Nuclide Concentration
[pCi/m2]
TC-99 1.0OOE+00 RESRAD-BUILD Dose Program Output, Version 3.50 01/25/12 11:00:53 Page:
10 **
Title : Humboldt Bay DCGLTc99 Input File : C:\\RESRADFamily\\BUILD\\3.5\\HBDCGL-TC99.bld Evaluation Time:
0.00000000E+00 years RESRAD-BUILD Dose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Source Total 1
2 3
4 5
6 Receptor 1
1.69E-08 7.32E-09 4.72E-09 7.14E-09 4.72E-09 1.68E-08 5.76E-08 Total 1.69E-08 7.32E-09 4.72E-09 7.14E-09 4.72E-09 1.68E-08 5.76E-08 1,
A RT L E TT Page 112