HBAP C-20.1 Rev. 7A Page 1 of 1 HUMBOLDT BAY POWER PLANT CALCULATION COVER SHEET File No. :

Calculation No.:

GEO.HBIP.02.06 El Preliminary 1 Final Department/Group:

HBPP/Geosciences Unit(s) 0 Structure, System or Component:

ISFSI Geotechnical Type or Purpose of Calculation:

Site Amplification Factors for HBIP No. of Sheets:

196 Signature Discipline/Dept Date Prepared by-Checked by:

Approved by (Sups By Geosciences By Geosciences v):

hippo WiAE 11/6/2002 11/7/2002 12/26/2002 Registered Engineer Approval: (Complete sein A for Civil calcs. Complete A or B for others A. Insert Engineer Stamp or Seal Below B.

Engineer's full name:

By Geosciences Registration Number:

Expiration Date:

Expiration Date:

RECORTS OF REVISTONS Approval Revision Prepared Checked Regis. Engr.

Supvr.

Number Date Reasons for Revision

-_ByBy 0

12/26/02 Initial Issue Geosc.

Geosci.

Geosci.

_t I I I

I I~~~~~~~~~~~~~~~~~~~

PACIFIC GAS AND ELECTRIC COMPANY GEOSCIENCES DEPARTMENT CALCULATION DOCUMENT Calc Number: GEO.HBIP.02.06 Revision: 0 Date: November 6, 2002 Calc Pages:

q Verification Method: A TITLE:

5 e

Arzp~~~~I 1,-a cr

,SI PREPARED BY:

I f

i f

DATE.

i//

/o/ Norm Abrahamson Printed Name Geosciences Organization VERIFIED BY:

DATE Josenh Sun

(

/((7/ 0 ~-

Printed Name x~ii>b~;

Organization

§ty' APPROVED BY:

DATE

/

Lloyd Cluff Printed Name Geosciences Organization

PG&E Geosciences Department Departmental Calculation and Data Report Procedure.4

Title:

Record of Revisions Number:

Revision:

Page:

GEO.001 05 1 of2 Rev.

Reason for Revision

.Revision No.

Date 00 Inita Issue 11/6/06

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 1 of 196 Date: 11/06/02

2. PURPOSE The purpose of this calculation is to quantify frequency dependent ground motion amplification induced by dynamic site response at the HBPP ISFSI site as part of Geosciences Work Plan GEO HBPP 2002-02. The soil amplification factors will be used to estimate site-specific surface ground motions for HBIP.
3. ASSUMPTIONS 3.1 Spectral Accelerations for Very Short Spectral Periods The spectral acceleration at spectral periods less than 0.02 seconds period is assumed to be equivalent to peak ground acceleration. The basis for the assumption is that there is no significant energy above 50 Hz in soil site time histories (Abrahamson and Silva, 1997).

3.2 Empirical Constraints on the Spectral Content The equivalent linear site response method used in the SHAKE program tends to overdamp the high frequencies for large input motions such as those used for HBPP.

Large amplitude ground motions recorded during the Jan. 15, 1994 Northridge, CA earthquake on seven soil sites listed below are assumed to have similar high frequency spectral shapes to the site response at HBIP for large amplitude ground motions.

Table 3.1 Time histories used for constraining the high frequency spectral shape Stations PGA Rinaldi Receiving Station 0.84g Sepulveda VA 0.94g Sylmar Converter Station 0.90g Sylmar Converter Station east 0.83g Sylmar Olive View Free-Field 0.84g Newhall Fire Station 0.59g Jensen Filtration Plant 0.59g The basis for this assumption is that the seven selected recordings are from soil sites with similar velocity profiles to the velocity profile at HBPP (driss, 2002) and the recorded peak accelerations at these stations are large. Given the high levels of ground motion and the similar velocity profile range, the high frequency spectral content is expected to be representative of the high frequency spectral shape at HBPP for large ground motions.

Calc Number. GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 2 of 196 Date: 11/06/02 3.3 Earthquake Time Histories for Site Response Analsis Using SHAKE Since the site response is only used to get amplification factors (expressed as spectral ratios between the computed surface motion with respect to the input motion), the results are not very sensitive to selection of the input time histories, so the choice of time histories is not critical as long as they have the appropriate spectral content.

The three acceleration time histories listed below are assumed to be representative of the input motion for large magnitude earthquakes at short distances. Sets 2 and 3 are composite time histories that were developed for the evaluation of the new San Francisco-Oakland Bay Bridge (Fugro, 1998). In these composite time histories, the long duration of large magnitude earthquakes was modeled by combining two time histories (one after the other). The long duration is appropriate to represent the Cascadia subduction zone event.

Table 3.2 Time histories used for the site response analysis Set Earthquake Date EQ Distance Station Component Mag (km) 1 Tabas 9/16/78 7.4 3.0 Tabas Fault Parallel 2

El Centro &

5/19/40 7.0 8.3 El Centro #9 Fault Imperial Valley 10/15/79 6.5 1.1 El Centro #6 Parallel Composite 3

Landers 6/28/92 7.3 1.1 Lucerne Fault Composite 11.6 Joshua Tree Parallel The basis for this assumption is that the design earthquake is dominated by a magnitude 7.7 rupture of the Little Salmon fault with increased duration from the synchronous rupture with the Cascadia subduction zone (GEO.HBIP.02.04, rev 0). These time histories have a broad spectral content (Figure 3-1). The basis for selecting the fault parallel component is that there is a concern that the soil column will be overdriven by the high ground motion levels and the use of the fault normal component, with its increased long period (and therefore increased soil strains) will increase the potential for overdriving the soil column that could result in lower computed amplification factors.

3.4 Reasonableness of Site Response Analysis Under High Ground Acceleration The reasonableness of the ground response analysis results using equivalent linear procedure by SHAKE was judged based on the evaluation of maximum shear strains developed in the profiles and the smooth trend in the computed surface responses with increasing input acceleration. For each profile and each time history, the three motions were scaled from 0.1 g to 1.0g in 0.1g increment, and from 1.2g, to 1.6g in 0.2g increment to evaluate the reasonableness in the computed surface response trend with increasing acceleration levels. The basis for this assumption is that non-linear soil properties(Seed and Idriss, 1970) used by SHAKE is defined to 10% strain. Effective

Calc Number GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 3 of 196 Date: 11/06/02 strains (typically taken as 2/3 of the maximum strains) in the range of 1% to 3% is generally consider within the reasonable strain range for the equivalent linear procedure.

This, in conjunction with a reasonable trend in the computed response with increasing levels of shaking provide a good basis for the evaluating the reasonableness of ground response analysis under high accelerations.

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 4 of 196 Date: 11/06/02 2.5 -

2.0 0q C

1.5 a)

C.,.

0 0.5 0.0 _

0.01 0.1 1

10 Period (sec)

Figure 3-1 Response Spectra for Ground Motions Used in Ground Response Analysis

Calc Number: GEO.HBIP.02.06 Rev Number. 0 Sheet Number: 5 of 196 Date: 11/06/02

4. INPUTS 4.1 Median Site Profile for HBIP The shear-wave velocity for the median soil profile at HBIP is listed in Table 4-1 (White, 2002). The non-linear properties (modulus and damping curves) for an equivalent linear analysis in the ground response analysis is also listed in Table 4-1 (White, 2002).

Calc Nurnber: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 6 of 196 Date: 11/06/02 Table 4-1. HBIP Median Site Soil Profile Layer Too of Layer Density Material Shear Nunbr Layer (ft)

Thickness (pcf)

Description Wave (fi)

Velocity (ft/sec)

I 0.0

3.

125.

Clay 750.

2 3.0

3.

125.

(Pi 15) 750.

3 6.0

4.

125.

750.

4

10.
5.

125.

750.

5

15.
5.

125.

750.

6

20.
5.

125.

Clay (PI 15) 1000.

7

25.
5.

130.

Sand (20-50')

1000.

8

30.
5.

130.

Sand 1150.

9

35.
5.

130.

(20-50')

1150.

10

40.
5.

130.

1150.

1

_ 45.

5.

__130.

1150.

12

50.

S.

130.

Clay 1500.

13

55.
5.

130.

(PI 15) 1500.

_14

60.

7.5 130.

Sand 1500.

15 67.5 7.5 130.

(50-120')

1500.

16

75.

7.5 130.

1500.

17_

82.5 7.5 130.-

1500.

18

90.
10.

130.

Sand 1750.

19 100.

11.

130.

(50-120')

1750.

20 Ill.

12.

130.

1750.

21 123.-

12.-

130.

1750.

22 135.

15.

130.

Sand(120-250')

2000.

23 150.

13.

130.

Clay 1550.

24 163.

13.

130.

(PI 15) 1550.

25

--176.

_13.

130.

1550.

26 189.

13.

130.

1550.

27 202.

13.

130.

1550.

28 215.

15.

130.

Sand 1650.

29 230.

15.

130.

(120-250')

1650.

30 245.

15.

130.

1650.

31 260.

20.

130.

Sand 2000.

32 280.

20.

130.

(250-500')

2000.

33 300.

20.

130.

2000.

34 320.

20.

130.

Sand 1800.

35 340.

20.

130.

(250-500')

1800.

36 360.

20.

130.

1800.

37 380.

20.

130.

1800.

38 400.

25.

130.

Sand 1900.

39 425.

25.

130.

(250-500')

1900.

40 450.

25.

130.

2000.

41 475.

25.

130.

2000.

42 500.

25.

130.

Sand 2100.

43 525.

25.

130.

(>500')

2100.

44 550.

25.

130.

2100.

45 575.

25.

130.

2100.

46 600.

Bedrock 5000.

Calc Number: GEO.HBIP.02.06 Rev Number- 0 Sheet Number: 7 of 196 Date: 11/06/02 4.2 Scale Factors for Upper and Lower Bound Soil Profiles The upper bound and lower bound profile is given by multiplying and dividing the shear modulus by a factor of 1.5, respectively (ASCE4, 1986, page 26). This corresponds to scaling the shear-wave velocity by factors of 1.22 (square root of 1.5).

4.3 Acceleration Time Histories from Northridge Earthquake The 14 Northridge acceleration time histories from 7 strong motion stations listed in Assumption 3.2 were downloaded from PEER strong motion data base at http://peer.berkeley.edu/smcat/.

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 8 of 196 Date: 11/06/02

5. METHOD AND EQUATION

SUMMARY

5.1 Methods 5.1.1 Site-Specific Amplification Factors The amplification factors are developed using the following steps:

1. Develop Soil Profiles Develop upper bound, and lower bound soil models using the median soil profile provided in Input 4.1 and the scaling factors from Input 4.2.
2. Select Input Time Histories Select three time histories for input into SHAKE96 based on Assumption 3.3.
3. Compute Site Response Compute site response for each of the three soil profiles using each of the three input time histories using program SHAKE96. Perform multiple runs using each input time history by scaling the input peak ground acceleration (PGA) to a range of values in accordance with Assumption 3.4.
4. Evaluate Site Response Results for Over-Softening of the Soil Profile in accordance with Assumption 3.4 Evaluate the results from the SHAKE runs (maximurn strains and spectral shape) to determine if there is a consistent trend in site response from low input peak ground acceleration (PGA) to high input PGA. If there is not a consistent trend, then develop a method for extrapolating the SHAKE analysis results from moderate to high peak ACCs to very high peak accelerations.
5. Compute Site Amplification Factors Compute amplification factors as response spectral ratio of surface ground motion to the input time histories for each PGA level. Surface ground motion spectra are computed within SHAKE96; spectra of input time histories are computed with SPCTLR.
6. Average the Amplification Factors Average the amplification factors (from step 4) for the three time histories for each PGA level and for each profile.

5.1.2 Empirical Constraints to the Spectral Shape Soil site recordings from the 1994 Northridge earthquake are used to develop empirical constraints on the spectral shape for large amplitude ground motions on soil sites. The spectral shape constraints are developed using the following steps.

1. Select Time Histories

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 9 of 196 Date: 11/06/02 The representative time histories from the 1994 Northridge earthquake are selected in accordance with Assumption 3.2 and Input 4.3.

2. Compute Response Spectra The response spectrum at 5% damping is computed for each time history.
3. Compute Average Spectral Shape The spectral shape is computed for each time history by dividing the response spectra with the corresponding PGA's (approximated with the spectral acceleration at 0.Olsecond in accordance with Assumption 3.1) and the average of the spectral shapes is computed.

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 10 of 196 Date: 11/06/02 5.2 Equations 5.2.1 Amplification factors are computed as the ratio of surface response spectral acceleration to input motion spectral acceleration.

AmpFac (t) =

a=Ltj Sa-msck(t)

(5-1) where Sa (t) is pseudo-absolute acceleration (spectral acceleration) at various periods (t).

5.2.2 The calculations use a statistic that we will call the "normalized standard error".

We define this statistic as the standard error of the mean normalized by the mean.

The mean, Ad of Nvalues, xi, is defined as (Bevington, 1969)

N xxi p N (5-2)

The standard deviation, a, of Nvalues, xi, is defined as (Bevington, 1969)

(xi - Py (N-1)

(5-3)

The standard error of the mean, SE[,qu, is defined as (Bevington, 1969)

SE[>] =

(5-4)

We define the normalized SE as Normalized SE = SEi]

(5-5)

I

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 11 of 196 Date: 11/06/02

6. SOFTWARE Two computer programs were used to develop the amplification functions: SHAKE96 and SPCTLR. SHAKE96 is compatible with verified software program SHAKE96S (White, 2002); SHAKE96 was used to compute site response including dynamic soil properties, surface ground motion time histories, and response spectra of the surface ground motions. SPCTLR (GEO.DCPP.01.32) is a verified software program used to compute ground motion response spectra of the input acceleration time histories.

6.1 Program SPCTLR The response spectrum calculation program SPCTLR.EXE is used to compute the response spectra of time histories. SPCTLR.EXE was verified in calculation GEO.DCPP.01.32 in accordance with Section 4.2.1 of GEO.001 Rev. 6.

6.2 Proram SHAKE96 The program used to compute site response is SHAKE96.EXE (termed SHAKE96 throughout this calculation).

Program Name/Number: SHAKE96 Program Function: The program computes the site response of a horizontally layered soil system subjected to one-dimensional vertically propagating body waves. Input includes a soil model, dynamic soil properties (shear modulus, damping) as a function of soil strain, and acceleration time history. Output includes the soil response (uniform strains, shear moduli, and damping values for all Model layers), acceleration time histories, peak shear strains, and response spectra.

Computer Platform: The program was developed for a DOS operating system running on a pc platform and was executed in DOS on a pc platform.

Capacity and Limitations: Maximum number of ACC data points is 16,384.

Users Manual

Reference:

The SHAKE96 users manual is the same as SHAKE91 (Idriss and Sun, 1992)

Program Certification: SHAKE96 was certified for the above uses under GEO.001 Rev 6 Method 3. A test case was run to compare the results from SHAKE96 and a previously certified and accepted SHAKE96S (White, 2002). Output files from both programs are included on the calculation CD-ROM (under subdirectory "SHAKE96 Test Run") and several output parameters are compared on an Excel spreadsheet. A typical comparison, between spectral accelerations, is shown in Table 6-1. Because the differences between results of SHAKE96 and SHAKE96S are only nominal, SHAKE96 may be used for this calculation according to GEO.001 Rev 6, Section 4.2.2, Method 3.

Calc Number: GEO.HBIP.02.06 Rev Number: 0 SheetNunber: 12 of 196 Date: 11/06/02 Table 6-1. Comparison of spectral accelerations computed using verified program SHAKE96S and SHAKE96.EXE Period Percent (secL SHAKE96S SHAKE96.EXE Difference 0.01 0.19201 0.19201 0.0000 0.03 0.19169 0.19169 0.0000 0.04 0.1917 0.1917 0.0000 0.05 0.19367 0.19367 0.0000 0.06 0.1957 0.1957 0.0000 0.07 0.19552 0.19552 0.0000 0.08 0.21533 0.21533 0.0000 0.09 0.21904 0.21904 0.0000 0.1 0.23911 0.23911 0.0000 0.11 0.26758 0.26758 0.0000 0.12 0.27821 0.27821 0.0000 0.13 0.26241 0.26241 0.0000 0.14 0.27509 0.27509 0.0000 0.15 0.27009 0.27009 0.0000 0.16 0.25978 0.25978 0.0000 0.17 0.27639 0.27639 0.0000 0.18 0.25895 0.25895 0.0000 0.19 0.26791 0.26791 0.0000 0.2 0.27254 0.27254 0.0000 0.21 0.27491 0.27491 0.0000 0.22 0.27313 0.27313 0.0000 0.23 0.29866 0.29866 0.0000 0.24 0.32505 0.32505 0.0000 0.25 0.37716 0.37716 0.0000 0.26 0.42656 0.42656 0.0000 0.27 0.44557 0.44557 0.0000 0.28 0.43921 0.43921 0.0000 0.29 OA5779 0.45779 0.0000 0.3 0.46268 0.46268 0.0000 0.31 0.44963 0.44963 0.0000 0.32 0.47659 0.47659 0.0000 0.33 0.54595 0.54595 0.0000 0.34 0.60503 0.60503 0.0000 0.35 0.65076 0.65076 0.0000 0.36 0.69821 0.69821 0.0000 0.37 0.76461 0.76461 0.0000 0.38 0.79666 0.79666 0.0000 0.39 0.80748 0.80748 0.0000 0.4 0.81635 0.81635 0.0000 0.41 0.83892 0.83892 0.0000 0.42 0.8269 0.8269 0.0000 0.43 0.80722 0.80722 0.0000 0.44 0.78926 0.78926 0.0000 0.45 0.77888 0.77888 0.0000 0.46 0.7614 0.7614 _

_0.0000 0.47 0.74117 0.74117 0.48 0.7033 0.7033 0.0000

Calc Number. GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 13 of 196 Date: 11/06/02 Table 6-1. (cont) Comparison of spectral accelerations computed using verified program SHAKE96S and SHAKE96.EXE 0.49 0.6501 0.6501 0.0000 0.5 0.60276 0.60276 0.0000 0.51 0.57675 0.57675 0.0000 0.52 0.57802 0.57802 0.0000 0.53 0.5937 0.5937 0.0000 0.54 0.61083 0.61083 0.0000 0.55 0.6035 0.6035 0.0000 0.56 0.58431 0.58431 0.0000 0.57 0.54511 0.54511 0.0000 0.58 0.51138 0.51138 0.0000 0.6 0.45241 0.45241 0.0000 0.62 0.43985 0.43985 0.0000 0.64 0.46379 0.46379 0.0000 0.66 0.47641 0.47641 0.0000 0.68 0.45701 0.45701 0.0000 0.7 0.41483 0.41483 0.0000 0.72 0.37998 0.37998 0.0000 0.74 0.3347 0.3347 0.0000 0.76 0.28821 0.28821 0.0000 0.78 0.25317 0.25317 0.0000 0.8 0.23135 0.23135 0.0000 0.82 0.21926 0.21926 0.0000 0.84 0.21067 0.21067 0.0000 0.86 0.20206 0.20206 0.0000 0.88 0.19994 0.19994 0.0000 0.9 0.20349 0.20349 0.0000 0.92 0.20483 0.20483 0.0000 0.94 0.20296 0.20296 0.0000 0.96 0.19864 0.19864 0.0000 0.98 0.19387 0.19387 0.0000 1

0.1882 0.1882 0.0000 1.05 0.17271 0.17271 0.0000 1.1 0.16299 0.16299 0.0000 1.15 0.15839 0.15839 0.0000 1.2 0.15122 0.15122 0.0000 1.25 0.13815 0.13815 0.0000 1.3 0.12284 0.12284 0.0000 1.35 0.10606 0.10606 0.0000 1.4 0.08937 0.08937 0.0000 1.45 0.0894 0.0894 0.0000 1.5 0.08476 0.08476 0.0000 1.55 0.07987 0.07987 0.0000 1.6 0.07656 0.07656 0.0000 1.65 0.07291 0.07291 0.0000 1.7 0.06984 0.06984 0.0000 1.75 0.06764 0.06764 0.0000 1.8 0.06612 0.06612 0.0000 1.85 0.06495 0.06495 0.0000 1.9 0.06393 0.06393 0.0000

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 14 of 196 Date: 11/06/02 Table 6-1. (cont) Comparison of spectral accelerations computed using verified program SHAKE96S and SHAKE96.EXE 1.95 0.06256 0.06256 0.0000 2

0.0608 0.0608 0.0000 2.05 0.05887 0.05887 0.0000 2.1 0.0567 0.0567 0.0000 2.15 0.05462 0.05462 0.0000 2.2 0.05241 0.05241 0.0000 2.25 0.05184 0.05184 0.0000 2.3 0.05234 0.05234 0.0000 2.35 0.05245 0.05245 0.0000 2.4 0.05201 0.05201 0.0000 2.5 0.04945 0.04945 0.0000 2.6 0.04548 0.04548 0.0000 2.7 0.04171 0.04171 0.0000 2.8 0.03766 0.03766 0.0000 2.9 0.0354 0.0354 0.0000 3

0.03277 0.03277 0.0000 3.1 0.02891 0.02891 0.0000 3.2 0.02633 0.02633 0.0000 3.3 0.02567 0.02567 0.0000 3.4 0.02466 0.02466 0.0000 3.5 0.02324 0.02324 0.0000 3.6 0.02141 0.02141 0.0000 3.7 0.01935 0.01935 0.0000 3.8 0.01834 0.01834 0.0000 3.9 0.01722 0.01722 0.0000 4

0.01606 0.01606 0.0000 4.1 0.0149 0.0149 0.0000 4.2 0.0138 0.0138 0.0000 4.3 0.01278 0.01278 0.0000 4.4 0.01186 0.01186 0.0000 4.5 0.0111 0.0111 0.0000 4.6 0.01065 0.01065 0.0000 4.7 0.01025 0.01025 0.0000 4.8 0.00991 0.00991 0.0000 4.9 0.00961 0.00961 0.0000 5

0.00961 0.00961 0.0000 5.1 0.00982 0.00982 0.0000 5.2 0.0099 0.0099 0.0000 5.4 0.00988 0.00988 0.0000 5.6 0.00976 0.00976 0.0000 5.8 0.00928 0.00928 0.0000 6

0.00877 0.00877 0.0000 6.2 0.00862 0.00862 0.0000 6.4 0.00809 0.00809 0.0000 6.6 0.00754 0.00754 0.0000 6.8 0.00697 0.00697 0.0000 7

0.00656 0.00656 0.0000

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 15 of 196 Date: 11/06/02 Table 6-1. (cont) Comparison of spectral accelerations computed using verified program SHAKE96S and SHAKE96.EXE 7.2 0.00619 0.00619 0.0000 7.4 0.00569 0.00569 0.0000 7.6 0.00532 0.00532 0.0000 7.8 0.00483 0.00483 0.0000 8

0.00447 0.00447 0.0000 8.5 0.0037 0.0037 0.0000 9

0.00295 0.00295 0.0000 9.5 0.00231 0.00231 0.0000 10 0.002 0.002 0.0000

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 16 of 196 Date: 11/06/02

7. BODY OF CALCULATIONS 7.1 Site-Specific Amplification Factors 7.1.1 Step 1: Develop Soil Profiles The soil profile for the median case is given in Table 4-1. Using Input 4.2, the shear-wave velocity for the upper bound and lower bound profiles are developed by scaling the median shear-wave velocity by a factor of sqrt(l.5) and 1/sqrt(1.5), respectively. The resulting upper bound and lower bound velocity profiles are listed in Table 7-1.

7.1.2 Step 2: Select Input Time Histories The input time histories for the site response are selected using Assumption 3.3. The digital values of the time histories are given on the enclosed CD under subdirectory "inpuLth" (Enclosure 1).

7.1.3 Step 3: Compute Site Response The three soil profiles and the three input time histories are used as input to SHAKE96 site response analyses.

Each time history is scaled to 13 different levels of input PGA (0.1 g, 0.2g, 0.3g, 0.4g, 0.5g, 0.6g, 0.7g, 0.8g, 0.9g, 1.0g, 1.2g, 1.4g, and 1.6g). Table 7-2 summarizes the run permutations. All input and output files used in the calculations are included on the calculation CD-ROM under subdirectories with names ending with " runs" (Enclosure 1).

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 17 of 196 Date: 11/06/02 Table 7-1. SHAKE dynamic model Layer Top of Layer Density Material Shear Wave Velocty (fUlsec)

Number Layer (ft) Thickness (pcf)

Description Median Lower Upper (ft) _

Profile Bound Bound I1 I

0.0

3.

125.

Clay 750.

615.

915.

2 3.0

3.

125.

(PI 15) 750.

615.

915.

3 6.0

4.

125.

750.

615.

915.

4

10.
5.

125.

750.

615.

915.

5

15.
5.

125.

750.

615.

915.

6

20.
5.

125.

Clay (PI 15) 1000.

820.

1220.

7

25.
5.

130.

Sand (20-50')

1000.

820.

1220.

8

30.
5.

130.

Sand 1150.

943.

1403.

9

35.
5.

130.

(20-50')

1150.

943.

1403.

t0

40.
5.

130.

1150.

943.

1403.

11

45.
5.

130.

1150.

943.

1403.

12

50.
5.

130.

Clay 1500.

1230.

1830.

13

55.
5.

130.

(PI 15) 1500.

1230.

1830.

14

60.

7.5 130.

Sand 1500.

1230.

1830.

15 67.5 7.5 130.

(50-120')

1500.

1230.

1830.

16

75.

7.5 130.

1500.

1230.

1830.

17 82.5 7.5 130.

1500.

1230.

1830.

18

90.
10.

130.

Sand 1750.

1434.

2135.

19 100.

11.

130.

(50-120')

1750.

1434.

2135.

20 111.

12.

130.

1750.

1434.

2135.

21 123.

12.

130.

1750.

1434.

2135.

22 135.

15.

130.

Sand (120-250')

2000.

1639.

2440.

23 150.

13.

130.

Clay 1550.

1270.

1891.

24 163.

13.

130.

(PI 15) 1550.

1270.

1891.

25 176.

13.

130.

1550.

1270.

1891.

26 189.

13.

130.

1550.

1270.

1891.

27 202.

13.

130.

1550.

1270.

1891.

28 I

215.

15.

130.

Sand 1650.

1352.

2013.

29 230.

15.

130.

(120-250')

1650.

1352.

2013.

30 245.

15.

130.

1650.

1352.

2013.

31 260.

20.

130.

Sand 2000.

1639.

2440.

32 280.

20.

130.

(250-500')

2000.

1639.

2440.

33 300.

20.

130.

2000.

1639.

2440.

34 320.

20.

130.

Sand 1800.

1475.

2196.

35 340.

20.

130.

(250-500')

1800.

1475.

2196.

36 360.

20.

130.

1800.

1475.

2196.

37 380.

20.

130.

1800.

1475.

2196.

38 400.

25.

130.

Sand 1900.

1557.

2318.

39 425.

25.

130.

(250-500')

1900.

1557.

2318.

40 450.

25.

130.

2000.

1639.

2440.

41 475.

25.

130.

2000.

1639.

2440.

42 500.

25.

130.

Sand 2100.

1721.

2562.

43 525.

25.

130.

(> 500')

2100.

1721.

2562.

44 550.

25.

130.

2100.

1721.

2562.

45 575.

25.

130.

2100.

1721.

2562.

46 600.

.050 Bedrock 5000.

4098.

6100.

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 18 of 196 Date: 11/06/02 Table 7-2. Matrix of input parameters for SHAKE96 computations Profile Input Time History Input pga (W)

Median Magnitude 7.8 (Sets 1, 2, and 3) 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7,0.8, 0.9, 1.0, 1.2, 1.4, 1.6 Lower Bound Magnitude 7.8 (Sets 1, 2, and 3) 0.1,0.2,0.3,0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0, 1.2,1.4,1.6 Upper Bound Magnitude 7.8 (Sets 1, 2, and 3) 0.1, 0.2,0.3, 0.4,0.5, 0.6, 0.7,0.8, 0.9, 1.0, 1.2,1.4, 1.6 7.1.4 Step 4: Evaluation of SHAKE Runs at Hih Ground Motion Levels The SHAKE runs at high input ground motion levels are evaluated in two ways. First, the maximum strains are checked. Second, the evolution of the spectral shape as a function of the input ground motion level is checked.

Maximum shear strains for the three time histories used to compute the amplification factors are listed in Table 7-3. These values are plotted in Figures 7-1 through 7-9 for input excitations of 0.6g through 1.6 g with 0.2g increment and the peak maximum strains (largest of the maximum strains) averaged over the three earthquakes are shown in Fig. 7-10 for input accelerations varying from O.lg to 1.6g. For all earthquakes, the maximum shear strains developed within each profile change in a regular manner. The peak maximum shear strains gradually increase with increasing acceleration levels without abnormal or abrupt trends. This is evidence that SHAKE96 computations are not breaking down with increasingly large levels of ground motion for this case. The effective shear strain is typically taken as 2/3 of the maximum shear strain and with maximum shear strain of 2.5% or effective strain of 1.6%, the equivalent linear approach is expected to perform well as in this strain range. This is also evident from the smooth change in peak surface accelerations with increasing input motions for all three profiles.

The response spectra shapes were computed by normalizing the spectra computed in SHAKE96 by the surface motion PGA (PGA values are listed in Table 7-4). The spectral shapes for each case are given in Appendix A. The average shapes for each profile are listed in Table 7-5 through 7-7 and plotted in Figures 7-11 through 7-13 for input accelerations above 0.6g. These plots shows that the spectral shapes evolve regularly to longer period with increasing levels of input pga with no dramatic changes in frequency content. This is further evidence that the equivalent linear method is still appropriate at these levels of input motion.

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 19 of 196 Date: 11/06/02 Table 7-3. Maximum shear strains (%) for three M7.8 earthquakes Input Earthquake 1 Earthquake 2 Earthquake 3 pga Median Lower Upper Median Lower Upper Median Lower Upper

(. )

Profile Bound Bound Profile Bound Bound Profile Bound Bound 0.1g 0.022 0.032 0.016 0.021 0.033 0.022 0.028 0.040 0.020 0.2g 0.050 0.073 0.038 0.053 0.077 0.045 0.070 0.081 0.047 0.3g 0.081 0.116 0.066 0.101 0.124 0.069 0.133 0.130 0.082 0.4g 0.118 0.157 0.098 0.164 0.189 0.090 0.189 0.182 0.125 0.5g 0.173 0.204 0.130 0.232 0.271 0.115 0.242 0.248 0.180 0.6g 0.229 0.301 0.163 0.306 0.381 0.152 0.308 0.352 0.249 0.7R 0.289 0.474 0.199 0.385 0.481 0.214 0.414 0.503 0.339 0.8g 0.350 0.602 0.243 0.452 0.513 0.301 0.491 0.612 0.450 0.9g 0.417 0.756 0.299 0.488 0.650 0.440 0.533 0.734 0.507 1.Og 0.470 0.954 0.379 0.541 0.803 0.536 0.608 0.884 0.571 1.2g 0.599 1.634 0.532 0.680 1.238 0.716 0.775 1.492 0.710 1.4g 0.863 2.034 0.643 0.833 1.738 0.896 1.157 1.897 0.901 1.6g 1.510 2.560 0.746 0.955 1.977 1.033 1.726 2.242

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 20 of 196 Date: 11/06/02 Figure 7-1. Depth dependence of maximum strains (%), median profile, Ground Motion Set Maximum Shear Strain 0

0.2 0.4 0.6 0.8 1

1.2 1.4 1.6

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 21 of 196 Date: 11/06/02 Figure 7-2. Depth dependence of maximum strains, median profile, ground motion set 2 Maximum Shear Strain 0

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

100-200 3-am CD

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 22 of 196 Date: 11/06/02 Depth dependence of maximum strains (%/o), median profile, ground motion Figure 7-3.

set 3 Maximum 0

0.2 0.4 0.6 0.8 Shear Strain 1

1.2 1.4 1.6 1.8

Calc Number: GEO.HBIP.02.06 Rev Number 0 Sheet Number: 23 of 196 Date: 11/06/02 Figure 74. Depth dependence of maximum strains (%), lower bound profile, ground motion set 1 Maximum Shear Strain 0

0.5 1

1.5 2

2.5 3

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 24 of 196 Date: 11/06/02 Figure 7-5. Depth dependence of maximum strains, lower bound profile, ground motion set 2 Maximum Shear Strain 0

0.2 0.4 0.6 0.8 1

1.2 1.4 1.6 1.8 2

0o-E 100-200 C

it,;

=

300

Calc Number. GEO.HBIP.02.06 Rev Number: 0 Sheet Number 25 of 196 Date: 11/06/02 Figure 7-6. Depth dependence of maximum strains (%), lower bound profile, ground motion set 3 Maximum Shear Strain 0

0.5 1

1.5 2

2.5

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 26 of 196 Date: 11/06/02 Figure 7-7. Depth dependence of maximum strains (%), upper bound profile, ground motion set 1 Maximum Shear Strain 0

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 27 of 196 Date: 11/06/02 Figure 7-8. Depth dependence of maximum strains, upper bound profile, ground motion set 2 Maximum Shear Strain 0

0.2 0.4 0.6 0.8 1

1.2

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 28 of 196 Date: 11/06/02 Figure 7-9. Depth dependence of maximum strains (%), upper bound profile, ground motion set 3 Maximum Shear Strain 0

0.2 0.4 0.6 0.8 1

1.2

Calc Number: GEO.HBEP.02.06 Rev Number: 0 Sheet Number: 29 of 196 Date: 11/06/02 Figure 7-10. Dependence of peak maximum strains (%), averaged over three input earthquakes, on input pga 2.5-Median Profile 2-Lower Bound A Upper Bound CD E

0.6 0.8 1

Input Motion PGA (g)

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 30 of 196 Date: 11/06/02 Table 7-4. Surface motion peak ground accelerations (approximated by spectral acceleration at 0.01 sec period; see assumption 3. 1; in g)

Input PGA Median Lower Upper Earthquak Profle Bound Bound 1

0.6 0.675 0.513 0.805 1

0.8 0.800 0.495 0.985 1

1.0 0.855 0.494 1.088 1

1.2 0.890 0.483 1.114 1

1.4 0.880 0.493 1.226 1

1.6 0.872 0.538 1.304 2

0.6 0.592 0.574 0.616 2

0.8 0.762 0.610 0.663 2

1.0 0.894 0.626 0.790 2

1.2 0.991 0.613 0.943 2

1.4 1.056 0.609 1.095 2

1.6 1.088 0.642 1.251 3

0.6 0.571 0.532 0.758 3

0.8 0.683 0.563 0.938 3

1.0 0.877 0.583 1.059 3

1.2 0.957 0.595 1.141 3

1.4 0.976 0.619 1.231 3

1.6 0.959 0.659 1.347

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 31 of 196 Date: 11/06/02 Table 7-5. Average normalized spectral accelerations for median profile (average of time histories: Set 1, Set 2, and Set 3>

Period Input PGA (see) 0.6u 0.3 1.02 1.2 1.42 1.6 L 0.01 1.000 1.000 1.000 W.000 1.000 1.000 0.03 1.005 1.004 1.003 1.003 1.003 1.003 0.04 1.010 1.007 1.006 1.006 1.005 1.005 0.05 1.017 1.012 1.010 1.009 1.008 1.008 0.06 1.028 1.019 1.015 1.014 1.012 1.011 0.07 1.033 1.024 1.019 1.018 1.017 1.015 0.08 1.049 1.022 1.020 1.021 1.021 1.020 0.09 1.122 1.073 1.047 1.038 L.032 1.028 0.10 1.213 1.130 1.073 1.058 1.047 1.040 0.11 1.234 1.142 1.054 1.052 1.048 1.044 0.12 1.335 1.182 1.077 1.053 1.047 1.045 0.13 1.356 1.211 1.083 1.059 1.051 1.049 0.14 1.446 1.231 1.084 1.053 1.048 1.054 0.15 i

1.577 1.320 1.106 1.066 1.060 1.059 0.16 1.737 1.423 1.211 1.144 1.122 1.108 0.17 1.855 1.536 1.331 1.228 1.183 1.164 0.18 1.877 1.654 1.442 1.318 1.255 1.180 0.19 2.048 1.772 1.498 1.390 1.321 1.269 0.20 2.236 1.953 1.697 1.560 1.472 1.420 0.21 2.314 2.085 1.808 1.670 1.572 1.510 0.22 2.436 2.174 1.909 1.774 1.673 1.590 0.23 2.484 2.208 1.944 1.827 1.738 1.644 0.24 2.547 2.282 2.065 1.943 1.857 1.783 0.25 2.656 2.385 2.108 1.993 1.914 1.844 0.26 2.719 2.384 2.136 2.025 1.932 1.850 0.27 2.773 2.466 2.125 1.995 1.909 1.849 0.28 2.946 2.559 2.190 2.074 1.981 1.907 0.29 3.022 2.599 2.248 2.139 2.047 1.972 0.30 3.084 2.702 2.318 2.200 2.116 2.046 0.31 3.167 2.765 2.415 2.294 2.213 2.153 0.32 3.052 2.722 2.392 2.286 2.221 2.173 0.33

- 2.961 2.640 2.333 2235 2.165 2.122 0.34 3.058 2.769 2.402 2.310 2.257 2.217 0.35 3.087 2.792 2.491 2.408 2.345 2.311 0.36 2.862 2.794 2.540 2.465 2.418 2.384 0.37 2.826 2.848 2.590 2.547 2.510 2.486 0.38 2.815 2.874 2.714 2.664 2.629 2.609 0.39 2.794 2.923 2.750 2.719 2.712 2.736 0.40 2.706 2.875 2.821 2.824 2.845 2.871 0.41 2.587 2.854 2.884 2.944 2.968 2.985 0.42 2.479 2.761 2.916 2.997 3.034 3.051 0.43 2.349 2.647 2.845 2.943 2.994 3.023 0.44 2.208 2.454 2.681 2.838 2.929 2.967 0.45 2.053 2.263 2.508 2.697 2.823 2.884 0.46 2.067 2.144 2.418 2.651 2.779 2.835 0.47 2.041 2.110 2.253 2.513 2.692 2.786 0.48 2.073 2.070 2.195 2.410 2.587 2.676 0.49 2.121 2.039 2.171 2.354 2.529 2.647 0.50 2.098 2.030 2.136 2.318 2.465 2.521

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 32 of 196 Date: 11/06/02 Table 7-5 (cont)

Pcod Input PGA (sec) 0.6 l 0.8 g 1.02 i 1.2 e

1.42 1.6 X 0.51 2.086 1.979 2.076 2.251 2.389 2.440 0.52 2.070 1.913 1.991 2.153 2.284 2.336 0.53 2.135 1.954 1.963 2.071 2.205 2.265 0.54 2.185 2.008 2.026 2.136 2.232 2.270 0.55 2.225 2.048 2.052 2.160 2.233 2.271 0.56 2.265 2.111 2.054 2.163 2.227 2.25 0.57 2.247 2.129 2.071 2.151 2.212 2.176 0.58 2.289 2.108 2.059 2.132 2.202 2201 0.60 2.344 2.178 2.054 2.089 2.177 2.199 0.62 2.377 2.236 2.084 2.099 2.125 2.072 0.64 2.444 2.338 2.206 2.206 2.188 2.110 0.66 2.406 2.368 2.293 2.336 2.337 2.229 0.68 2.244 2.244 2.222 2.281 2.303 2.216 0.70 2.090 2.180 2.199 2.246 2.240 2.143 0.72 2.081 2.192 2.221 2.271 2.276 2.177 0.74 2.028 2.142 2.173 2.228 2.244 2.184 0.76 1.977 2.062 2.107 2.184 2.235 2.204 0.78 1.900 1.984 2.027 2.145 2.255 2.231 0.80 1.44 1.944 2.033 2.181 2.298 2.282 0.82 1.797 1.910 2.011 2.165 2.287 2.279 0.84 1.690 1.812 1.925 2.083 2.216 2.256 0.86 1.663 1.783 1.916 2.081 2.222 2.270 0.88 1.600 1.705 1.838 2.002 2.143 2.196 0.90 1.529 1.594 1.722 1.878 2.017 2.076 0.92 1.486 1.537 1.647 1.799 1.941 2.013 0.94 1.521 1.569 1.646 1.778 1.945 2.079 0.96 1.546 1.601 1.677 1.812 1.979 2.115 0.98 1.531 1.589 1.660 1.791 1.955 2.090 1.00 1.504 1.561 1.624 1.750 1.909 2.042 1.05 1.451 1.492 1.543 1.659 1.810 1.946 1.10 1.461 1.438 1.467 1.554 1.675 1.805 1.15 1.516 1.503 1.504 1.573 1.676 1.808 1.20 1.574 1.576 1.561 1.602 1.665 1.740 1.25 1.559 1.578 1.575 1.627 1.691 1.756 130 1.564 1.592 1.603 1.668 1.749 1.824 135 1.619 1.603 1.604 1.655 1.725 1.785 1.40 1.636 1.605 1.576 1.615 1.680 1.734 IAS 1.630 1.651 1.606 1.610 1.655 1.692 1.50 1.559 1.592 1.575 1.613 1.662 1.693 1.55 1.503 1.582 1.594 1.647 1.705 1.743 1.60 1.502 1.587 1.585 1.631 1.693 1.733 1.65 1.516 1.619 1.618 1.631 1.666 1.708 1.70 I.454 1.566 1.573 1.580 1.633 1.691 1.75 1.355 1.475 1.503 1.547 1.612 1.668 1.80 1.296 1.440 1.497 1.567 1.632 1.698 1.85 1.271 1.419 1.485 1.576 1.668 1.741 1.90 1.218 1.371 1.450 1542 1.632 1.730 1.95 U148 1.292 1.368 1.467 1596 1.708 2.00 1.066 1.211 1.297 1.435 1.593 1.27 2.05 1.011 I.175 1.286 1.422 1.571 1.699 2.10 1 0.943

!.097 1.206 1.344 1.484 1.591 2.15 0.884 1.017 1.114 1.242 1391 1.549

Calc Number GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 33 of 196 Date: 11/06/02 Table 7-5 (cont)

Period In PGA sec 0.6g (se) 0.6.

(see) 0.6 sec 2.20 0.839 0.962 1.054 1.186 1.355 1.526 2.25 0.799 0.919 1.010 1.147 1.323 1.491 2.30 0.757 0.874 0.965 1.109 1.279 1.448 2.35 0.712 0.828 0.922 1.061 1.225 1.386 2.40 0.667 0.780 0.873 1.005 1.163 1.325 2.50 0.600 0.704 0.789 0.909 1.062 1.223 2.60 0.572 0.670 0.749 0.864 1.012 1.176 2.70 0.513 0.604 0.681 0.790 0.932 1.091 2.80 0.464 0.539 0.606 0.705 0.835 0.983 2.90 0.424 0.484 0.538 0.622 0.737 0.867 3.00 0.405 0.460 0.511 0.591 0.697 0.816 3.10 0.393 0.441 0.484 0.559 0.661 0.776 3.20 0.371 0.419 0.459 0.527 0.623 0.748 3.30 0.342 0.388 0.430 0.495 0.586 0.696 3.40 0.338 0.385 0.425 0.487 0.571 0.672 3.50 0.325 0.372 0.411 0.473 0.558 0.655 3.60 0.295 0.337 0.374 0.433 0.513 0.607 3.70 0.272 0.310 0.344 0.396 0.466 0.553 3.80 0.261 0.298 0.331 0.380 0.445 0.520 3.90 0.254 0.291 0.324 0.373 0.439 0.516 4.00 0.239 0.276 0.308 0.357 0.423 0.500 4.10 0.223 0.252 0.279 0.324 0.387 0.461 4.20 0.197 0.223 0.249 0.293 0.350 0.415 4.30 0.187 0.212 0.236 0.276 0.329 0.389 4.40 0.179 0.200 0.222 0.260 0.311 0.369 4.50 0.175 0.192 0.211 0.245 0.292 0.348 4.60 0.171 0.191 0.208 0.235 0.277 0.331 4.70 0.171 0.191 0.208 0.235 0.272 0.320 4.80 0.165 0.184 0.199 0.224 0.261 0.308 4.90 0.162 0.180 0.195 0.220 0.252 0.298 5.00 0.154 0.173 0.188 0.212 0.243 0.284 5.10 0.145 0.163 0.178 0.201 0.232 0.268 5.20 0.137 0.155 0.169 0.193 0.225 0.263 5.40 0.127 0.144 0.158 0.182 0.213 0.250 5.60 0.109 0.120 0.132 0.151 0.179 0.212 5.80 0.107 0.117 0.127 0.142 0.164 0.189 6.00 0.104 0.115 0.124 0.140 0.162 0.187 6.20 0.097 0.106 0.115-0.130 0.151 0.176 6.40 0.093 0.103 0.110 0.124 0.143 0.165 6.60 0.087 0.096 0.104 0.118 0.137 0.159 6.80 0.082 0.091 0.098 0.111 0.129 0.151 7.00 0.079 0.088 0.095 0.108 0.124 0.144 7.20 0.076 0.085 0.092 0.103 0.119 0.138 7.40 0.073 0.079 0.085 0.096 0.112 0.130 7.60 0.069 0.076 0.081 0.090 0.104 0.120 7.80 0.064 0.070 0.075 0.084 0.097 0.112 8.00 0.057 0.063 0.068 0.077 0.089 0.103 8.50 0.049 0.054 0.058 0.065 0.074

.084 9.00 0.046 0.051 0.054 0.061 0.070 0.080 9.50 0.042 0.046 0.049 0.055 0.063 0.072 10.00 0.036 0.040 0.043 0.048 0.055 0.063

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 34 of 196 Date: 11/06/02 Table 7-6. Average normalized spectral accelerations for lower bound profile (average of time histories Set 1, Set 2, and Set 3)

Period InpU PGA (sec) 0.6f 0X g 1.0 1.2 1.4 1.6 0.01 1.000 1.000 1.000 1.000 1.000 1.000 0.03 1.004 1.004 1.003 1.002 1.002 1.002 0.04 1.007 1.007 1.005 1.004 1.003 1.003 0.05 1.012 1.011 1.008 1.006 1.005 1.005 0.06 1.019 1.016 1.012 1.009 1.007 1.007 0.07 1.025 1.023 1.016 1.013 1.010 1.010 0.08 1.032 1.031 1.020 1.016 1.013 1.013 0.09 1.058 1.046 1.028 1.023 1.016 I 1.016 0.10 1.078 1.058 1.041 1.028 1.019 1.019 0.11 1.103 1.079 1.048 1.038 1.023 1.024 0.12 1.121 1.085 1.046 1.040 1.026 1.027 0.13 1.116 1.078 1.057 1.049 1.036 1.030 0.14 1.133 1.099 1.078 1.068 1.043 1.037 0.15 1.182 1.141 1.114 1.096 1.050 1.043 0.16 1.224 1.170 1.148 1.123 1.066 1.047 0.17 1.358 1.251 1.183 1.167 1.129 1.090 0.18 1.491 1.366 1.238 1.222 1.186 1.111 0.19 1.582 1.441 1.333 1.261 1.194 1.148 0.20 1.789 1.665 1.536 IAIS 1.272 1.150 0.21 1.947 1.792 1.643 1.514 1.360 1.200 0.22 2.068 1.914 1.726 1561 1.407 1.302 0.23 2.150 1.999 1.810 1.638 1526 1.399 0.24 2.211 2.091 1.922 1.791 1.658 1.505 0.25 2.280 2.178 2.012 1.869 1.708 1.540 0.26 2.324 2.241 2.086 1.952 1.779 1.573 0.27 2.303 2.197 2.081 1.985 1.858 1.652 0.28 2.372 2.296 2.184 2.099 1.969 1.766 0.29 2.427 2.359 2.252 2.169 2.040 1.837 0.30 2.415 2.358 2.261 2.185 2.063 1.868 0.31 2.463 2.447 2.349 2.200 2.057 1.871 0.32 2.480 2.484 2.407 2.275 2.106 1.865 0.33 2.505 2.464 2.409 2.304 2.140 1.912 0.34 2.593 2.514 2.451 2.348 2.189 1.961 0.35 2.678 2.605 2.546 2.418 2.252 2.010 0.36 2.765 2.696 2.644 2.517 2.348 2.098 0.37 2.835 2.748 2.694 2.579 2.409 2.201 0.38 2.939 2.855 2.789 2.665 2.487 2.240 0.39 3.015 3.006 2.934 2.723 2.514 2.261 0.40 3.227 3.184 3.102 2.878 2.600 2.319 0.41 3.362 3.355 3.260 3.004 2.689 2.391 0.42 3A36 3.453 3.372 3.102 2.766 2.468 0.43 3.391 3.429 3.368 3.117 2.775 2.490 0.44 3.313 3.373 3.317 3.090 2.787 2.542 0.45 3.214 3.360 3.366 3.225 3.007 2.755 0.46 3.176 3.372 3.444 3.349 3.164 2.880 0.47 3.072 3.325 3.437 3.432 3.273 2.984 0.48 2.969 3.269 3.430 3.497 3.386 3.097 0.49 2.900 3.221 3.389 3.461 3.369 3.131 0.50 2.706 3.056 3.246 3.350 3.292 3.089

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number 35 of 196 Date: 11/06/02 Period In ut PGA (sec) 0.6 (sec) 0.6 (sec) 0.6 (see) 0.51 2.602 2.917 3.103 3.220 3.202 3.033 0.52 2.481 2.794 2.982 3.109 3.101 2.955 0.53 2.390 2.700 2.897 3.043 3.068 2.978 0.54 2.333 2.621 2.853 3.067 3.147 3.082 0.55 2.334 2.627 _2.866 3.089 3.178 3.116 0.56 2.284 2.577 2.820 3.050 3.147 3.104 0.57 2.219 2.482 2.726 2.960 3.103 3.126 0.58 2.172 2.358 2.626 2.917 3.082 3.120 0.60 2.134 2.359 2.559 2.831 3.064 3.169 0.62 2.047 2.166 2.334 2.572 2.798 2.909 0.64 2.122 2.188 2.298 2.498 2.678 2.811 0.66 2.213 2.206 2.250 2.430 2.634 2.773 0.68 2.174 2.181 2.197 2.308 2.457 2.561 0.70 2.171 2.156 2.156 2.232 2.353 2.470 0.72 2.207 2.184 2.191 2.255 2.294 2.377 0.74 2.180 2.192 2.195 2.265 2.287 2.288 0.76 2.124 2.205 2.169 2.234 2.266 2.247 0.78 2.134 2.231 2.228 2.249 2.242 2.183 0.80 2.165 2.273 2.267 2.295 2.291 2.226 0.82 2.146 2.265 2.276 2.314 2.312 2.248 0.84 2.057 2.279 2.313 2.344 2.342 2.275 0.86 2.037 2.280 2.319 2.360 2.353 2.288 0.88 1.952 2.192 2.243 2.315 2.297 2.240 0.90 1.822 2.062 2.144 2.242 2.229 2.163 0.92 1.735 1.993 2.137 2.228 2.219 2.132 0.94 1.703 2.055 2.232 2.303 2.248 2.155 0.96 1.712 2.090 2.271 2.343 2.281 2.157 0.98 1.687 2.061.

2.248 2.329 2.267 2.139 1.00 1.641 2.018 2.247 2.328 2.257 2.121 1.05 1.536 1.897 2.145 2.316 2.308 2.196 1.10 1.412 1.724 1.987 2.225 2.329 2.265 1.15 1.389 1.713 1.996 2.266 2.387 2.342 1.20 1.365 1.610 1.869 2.138 2.287 2.315 1.25 1.376 1.571 1.749 L996 2.193 2.285 1.30 1.428 1.646 1.829 2.060 2.272 2.379 1.35 1.405 1.599 1.756 1.978 2.166 2.258 1.40 1.362 1.547 1.700 1.893 2.046 2.097 1.45 1.344 1.497 1.639 1.822 1.965 2.012 1.50 1.348 1.503 1.641 1.804 1.938 1.992 1.55 1.386 1.536 1.650 1.823 1.944 1979 1.60 1.368 1.521 1.627 1.789 1.904 1.924 1.65 1.337 1.492 1.599 1.759 1.876 1.897 1.70 1.329 1.488 1.597 1.741 1.844 1.858 1.75 1.312 1.464 1.579 1.717 1.817 1.830 1.80 1.327 1.489 1.603 1.737 1.835 1.47 1.85 1.343 1.522 1.641 1.765 1.851 1.865 1.90 1311 1.525 1.660 1.798 1.886 1.888 1.95 1283 1.532 1.670 1.811 1.901 1.908 2.00 1.289 1.547 1.682 1.836 1.950 1.967 2.05 1.272 1.515 1.662 1.816 1.934 1.956 2.10 1.196 1.426 1.613 1.770 1.853 1.874 2.15 1.108 1.401 1.596 1.747 1.843 1.852

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 36 of 196 Date: 11/06/02 Period Inut PGA (sec) 0.6 l (se) 0.6 (sec) 0.6 l (sec) 2.20 1.080 1.383 1.579 1.737 1.835 1.848 2.25 1.054 1.361 1.579 1.746 1.834 1.843 2.30 1.019 1.321 1.533 1.701 1.805 1.829 2.35 0.975 1.254 1.464 1.661 1.786 1.814 2.40 0.923 1.205 1.426 1.624 1.761 1.792 2.50 0.842 1.115 1.336 1.545 1.685 1.721 2.60 0.802 1.075 1.309 1.525 1.659 1.680 2.70 0.736 0.998 1.225 1.448 1.608 1.650 2.80 0.658 0.900 1.122 1.356 1.524 1.581 2.90 0.580 0.794 1.018 1.291 1.515 1.604 3.00 0.547 0.742 0.961 1.237 1.458 1.554 3.10 0.516 0.707 0.925 1.189 1.422 1.548 3.20 0.486 0.683 0.892 1.136 1.356 1.478 3.30 0.457 0.637 0.834 1.057 1.261 1.374 3.40 0.447 0.612 0.776 0.992 1.189 1.314 3.50 0.435 0.594 0.754 0.946 1.130 1.247 3.60 0.400 0.553 0.704 0.886 1.050 1.160 3.70 0.364 0.503 0.644 0.812 0.968 1.069 3.80 0.345 0.468 0.602 0.763 0.922 1.020 3.90 0.340 0.465 0.590 0.740 0.901 1.003 4.00 0.327 OA52 0.578 0.725 0.874 0.976 4.10 0.299 0.418 0.539 0.679 0.821 0.911 4.20 0.271 0.377 0.487 0.619 0.751 0.835 4.30 0.254 0.351 0.448 0.569 0.693 0.777 4.40 0.240 0.334 0.426 0.539 0.656 0.737 4.50 0.225 0.313 0.405 0.514 0.625 0.700 4.60 0.213 0.297 0.386 0.491 0.588 0.659 4.70 0.210 0.285 0.368 0.469 0.563 0.624 4.80 0.201 0.276 0.351 0.442 0.532 0.590 4.90 0.196 0.267 0.341 0.428 0.506 0.557 5.00 0.189 0.255 0.328 0.413 0.490 0.536 5.10 0.180 0.240 0.309 0.391 0.464 0.510 5.20 0.174 0.236 0.300 0.376 0.446 0.489 5.40 0.165 0.224 0.286 0.360 0.428 0.472 5.60 0.138 0.191 0.247 0.313 0.376 0.417 5.80 0.127 0.168 0211 0.264 0.312 0.347 6.00 0.125 0.166 0.208 0.258 0.304 0.332 6.20 0.117 0.157 0.197 0.246 0.289 0.316 6.40 0.110 0.146 0.183 0.227 0.266 0.288 6.60 0.105 0.141 0.177 0.219 0.256 0.279 6.80 0.099 0.134 0.169 0.209 0.246 0.269 7.00 0.096 0.128 0.162 0.202 0.239 0.261 7.20 0.092 0.122 0.153 0.192 0.228 0.251 7.40 0.086 0.115 0.144 0.177 0.208 0.227 7.60 0.080 0.106 0.132 0.164 0.193 0.210 7.80 0.074 0.099 0.124

-0.154 0.182 0.198 8.00 0.068 0.091 0.115 0.143 0.169 0.184 8.50 0.057 0.075 0.092 0.112 0.133 0.145 9.00 0.054 0.071 0.088 0.107 0.124 0.133 9.50 0.049 0.064 0.079 0.095 0.110 0.119 10.00 0.043 0.056 0.070 0.085 0.098 0.106

Calc Number-GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 37 of 196 Date: 11/06/02 Table 7-7. Average normalized spectral accelerations for upper bound profile (average of time histories Set 1, Set 2, and Set 3)

Period InPUt PGA (sec) 0.6 7 0.1 1.0!

1.2 s 1.4!

1.6 0.01 1.000 1.000 1.000 1.000 1.000 1.000 0.03 1.012 1.010 1.007 1.005 1.003 1.003 0.04 1.026 1.023 1.013 1.010 1.006 1.006 0.05 1.042 1.036 1.021 1.017 1.009 1.009 0.0 1.053 1.058 1.027 1.024 1.016 1.012 0.07 1.137 1.127 1.054 1.037 1.020 1.018 0.08 1.199 1.166 1.102 1.052 1.033 1.024 0.09 1.342 1.252 1.171 1.122 1.061 1.051 0.10 1.470 1.364 1.263 1.192 1.113 1.065 0.11 1.499 1.436 1.333 1.245 1.144 1.056 0.12 1.614 1.541 IA23 1.318 1.199 1.095 0.13 1.750 1.663 1.446 1.289 1.198 1.122 0.14 1.844 1.739 1.531 1.348 1.212 1.142 0.15 1.957 1.913 1.712 1.493 1.295 1.176 0.16 2.074 2.034 1.822 1.624 1.418 1.264 0.17 2.249 2.169 1.915 1.691 1.481 1.351 0.18 2.233 2.183 1.966 1.770 1.588 IA23 0.19 2.409 2.243 2.069 1959 1.760 1.564 0.20 2.564 2.362 2.237 2.131 1.929 1.706 0.21 2.758 2.527 2.334 2.198 2.007 1.801 0.22 2.970 2.683 2.477 2.317 2.108 1.901 0.23 3.077 2.859 2.514 2.370 2.166 1.970 0.24 3.210 3.053 2.701 2.481 2.270 2.067 0.25 3.357 3.288 2.910 2.622 2.376 2.146 0.26 t 3.394 3.357 3.047 2.752 2.416 2.183 0.27 3.293 3.361 3.113 2.768 2.453 2.179 0.28 3.253 3.422 3.247 2.940 2.636 2.357 0.29 3.100 3.206 3.145 2.999 2.754 2.471 0.30 2.940 3.096 3.012 2.891 2.711 2.504 0.31 2.778 2.906 2.896 2.896 2.756 2.542 0.32 2.635 2.788 2.791 2.806 2.680 2.502 0.33 2.577 2.707 2.682 2.635 2.526 2.362 0.34 2.534 2.629 2.593 2.581 2.489 2.397 0.35 2.502 2.609 2.587 2.583 2.496 2.373 0.36 2.400 2.519 2.502 2.498 2.469 2.389 0.37 2.380 2.447 2.453 2.501 2.508 2.479 0.38 2.363 2.481 2.445 2.490 2.508 2.493 0.39 2.315 2.420 2.409 2.456 2.487

-2.476 0.40

_ 2.344 2.313 2.307 2.361 2.407 2.454 0.41 2.425 2.252 2.212 2.278 2.374 2.452 0.42 2.481 2.300 2.114 2.206 2.304 2.415 0.43 2.523 2.335 2.121 2.112 2.212 2.328 0.44 2.444 2.292 2.087 2.007 2.074 2.172 0.45 2.537 2.404 2.133 1.987 1.930 1.988 0.46 2.632 2.525 2.259 2.095 2.000 2.030 0.47 2.610 2.521 2.289 2.144 2.035 2.008 0.48 2.535 2.467 2.275 2.147 2.050 2.004 0.49 2.525 2.480 2.297 2.174 2.082 2.039 0.50 2.387 2.457 2.304 2.171 2.074 2.036

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 38 of 196 Date: 11/06/02 Period Inut PGA (sec) 0.6 (sec) 0.6 (sec) 0.6 g (sec) 0.51 2.311 2.415 2.300 2.168 2.051 1.991 0.52 2.228 2.368 2.284 2.171 2.034 1.953 0.53 2.150 2.346 2.305 2.213 2.088 1.990 0.54 2.157 2.409 2.374 2.282 2.162 2.071 0.55 2.164 2.413 2.395 2.323 2.205 2.103 0.56 2.118 2.398 2.420 2.359 2.248 2.165 0.57 2.052 2.353 2.388 2.364 2.278 2.184 0.58 2.002 2.264 2.372 2.426 2.337 2.238 0.60 1.999 2.267 2.431 2.482 2.390 2.294 0.62 1.880 2.139 2.280 2.382 2.370 2.317 0.64 1.737 2.023 2.222 2.411 2.436 2.407 0.66 1.707 1.974 2.194 2.389 2.434 2.433 0.68 1.706 1.926 2.082 2.259 2.305 2.320 0.70 1.771 1.958 2.056 2.167 2.223 2.259 0.72 1.788 1.980 2.084 2.186 2.239 2.271 0.74 1.786 1.985 2.093 2.183 2.197 2.225 0.76 1.751 1.956 2.071 2.164 2.180 2.188 0.78 1.679 1.883 2.000 2.093 2.108 2.116 0.80 1.637 1.823 1.943 2.036 2.053 2.063 0.82 1.662 1.768 1.868 1.969 1.997 2.021 0.84 I 1.712 1.807 1.851 1.896 1.907 1.927 0.86 1.745 1.844 1.877 1.912 1.896 1.918 0.88 1.717 1.816 1.844 1.875 1.850 1.848 0.90 1.663 1.757 1.781 1.806 1.779 1.765 0.92 1.653 1.745 1.762 1.778 1.744 1.724 0.94 1.699 1.801 1.822 1.838 1.803 1.780 0.96 1.731 1.829 1.851 1.872 1.839 1.816 0.98 1.729 1.811 1.831 1.853 1.824 1.802 1.00 1.729 1.800 1.809 1.822 1.794 1.772 1.05 1.794 1.852 1.825 1.799 1.736 1.706 1.10 1.838 1.934 1.893 1.844 1.762 1.690 1.15 1.851 1.950 1.942 1.917 1.840 1.770 1.20 1.744 1.920 1.964 1.959 1.901 1.849 1.25 1.694 1.880 1.910 1.900 1.866 1.836 1.30 1.593 1.818 1.906 1.939 1.881 1.850 1.35 1.500 1.774 1.910 1.991 1.952 1.890 1.40 1.439 1.713 1.883 1.987 1.967 1.915 1.45 1.366 1.651 1.830 1.949 1.952 1.935 1.50 1.265 1.535 1.709 1.834 1.862 1.858 1.55 1.172 1.415 1.594 1.743 1.788 1.813 1.60 1.109 1.332 1.516 1.696 1.774 1.813 1.65 1.076 1.307 1.509 1.692 1.787 1.843 1.70 1.007 1.232 1.427 1.610 1.715 1.777 1.75 0.921 1.125 1.308 1.486 1.593 1.661 1.80 0.867 1.068 1.239 1.406 1.506 1.587 1.85 0.861 1.043 1.202 1370 1.476 1.559 1.90 0.826 1.007 1.165 1.325 IA24 1.503 1.95 0.766 0.936 1.089 1.244 1.341 1.419 2.00 0.710 0.864 1.001 1.149 1.246 1.326 2.05 0.669 0.812 0.941 1.078 1.176 1.262 2.10 0.638 0.772 0.886 1.008 1.095 1.180 2.15 0.602 0.732 0.841 0.957 1.036 1.108

Calc Number: GEO.HBIP.02.06 Rev Number. 0 Sheet Number: 39 of 196 Date: 11/06/02 Period Input PGA (sec) 0.6 (se) 0.6 a (sec) 0.6 (sec) 2.20 0.564 0.688 0.796 0.908 0.983 1.051 2.25 0.534 0.649 0.751 0.860 0.934 1.001 2.30 0.502 0.612 0.706 0.812 0.884 0.950 2.35 0.474 0.578 0.668 0.763 0.832 0.897 2.40 0.451 0.545 0.627 0.718 0.781 0.842 2.50 0.415 0.497 0.567 0.647 0.703 0.760 2.60 0.400 0.478 0.544 0.613 0.669 0.723 2.70 0.359 0.431 0.493 0.559 0.605 0.651 2.80 0.328 0.390 0.444 0.504 0.546 0.586 2.90 0.318 0.377 0.423 0.470 0.502 0.533 3.00 0.298 0.355 0.401 0.448 0.479 0.509 3.10 0.292 0.346 0.391 0.437 0.465 0.491 3.20 0.270 0.322 0.365 0.410 0.439 0.465 3.30 0.255 0.299 0.337 0.378 0.405 0.430 3.40 0248 0.291 0.329 0.371 0.399 0.425 3.50 0.236 0.278 0.313 0.354 0.383 0.409 3.60 0.2 14 0.254 0.287 0.324 0.348 0.372 3.70 0.192 0.231 0.265 0.300 0.323 0.345 3.80 0.184 0.222 0.254 0.289 0.311 0.332 3.90 0.183 0.217 0.247 0.281 0.303 0.324 4.00 0.179 0.211 0.238 0.267 0.286 0.306 4.10 0.167 0.196 0.221 0.248 0.266 0.282 4.20 0.149 0.174 0.195 0.219 0.235 0.250 4.30 0.149 0.172 0.190 0.210 0.224 0.238 4.40 0.146 0.169 0.185 0.202 0.214 0.225 4.50 0.143 0.165 0.181 0.198 0.208 0.218 4.60 0.137 0.159 0.175 0.192 0.204 0.215 4.70 0.135 0.157 0.174 0.192 0.204 0.214 4.80 0.129 0.152 0.169 0.186 0.197 0.207 4.90 0.125 0.148 0.165 0.182 0.193 0.202 5.00 0.118 0.139 0.156 0.172 0.183 0.193 5.10 0.110 0.130 0.145 0.162 0.172 0.182 5.20 0.105 0.122 0.137 0.152 0.163 0.173 5.40 0.099 0.114 0.126 0.140 0.151 0.160 5.60 0.092 0.106 0.116 0.125 0.131 0.136 5.80 0.086 0.101 0.112 0.122 0.128 0.134 6.00 0.082 0.097 0.108 0.118 0.125 0.131 6.20 0.077 0.090 0.100 0.109 0.115 0.120 6.40 0.075 0.087 0.096 0.105 0.111 0.116 6.60 0.070 0.082 0.090 0.099 0.104 0.109 6.80 0.068 0.077 0.084 0.093 0.098 0.103 7.00 0.065 0.075 0.082 0.090 0.095 0.100 7.20 0.062 0.071 0.079 0.086 0.091 0.096 7.40 0.060 0.069 0.076 0.083 0.087 0.091 7.60 0.056 0.065 0.072 0.079 0.083 0.086 7.80 0.052 0.060 0.066 0.073 0.077 0.080 8.00 0.047 0.055 0.060 0.066 0.069 0.072 8.50 0.042 0.048 0.052 0.056 0.059 0.061 9.00 0.038 0.044 0.048 0.052 0.055 0.057 9.50 0.034 0.040 0.044 0.048 0.050 0.052 10.00 0.029 0.034 0.037 0.040 0.042 0.045

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 40 of 196 Date: 11/06/02 Figure 7-11. Spectral shape of median profile, average of time histories Set 1, Set 2, and Set 3 3.5 0.6 g Input pga 0.8 g

1.

g AAX 3

1.2 2 2.5 1.6 g C

0 C) 0.5 0.01 0.1 1

10 Period (Sec)

Calc Number GEO.HBIP.02.06 Rev Number. 0 Sheet Number 41 of 196 Date: 11/06/02 Figure 7-12. Spectral shape of lower bound profile, average of time histories Set 1, Set 2, and Set 3 3.5 0.6 g Input pga 0.8g 0 -

1.O I

1.2 g i

1.4 g I:

E!2.5

1.

_g CL o

Il

0.

I1 0

0.01 0.1 1

10 Period (Sec)

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 42 of 196 Date: 11/06/02 Figure 7-13. Spectral shape of upper bound profile, average of time histories Set 1, Set 2, and Set 3 3.5,

a 0 '

l

.I 0.01 0.1 1

10 Perod (Sec)

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 43 of 196 Date: 11/06/02 7.1.5 Steo 5: Compute Amplification Factors Amplification factors are computed for input PGA levels of 1.2g, 1.4g. and 1.6g which is the expected acceleration range at HBIP. The amplification factor is computed using eq.

5-1 where the surface response spectra can be obtained by multiplying the normalized spectral shape included in Appendix A by the corresponding PGA listed in Table 7-4 and the corresponding input response spectra can be obtained by scaling the spectral shape listed in 7-8 by the PGA of 1.2g, 1.4g or 1.6g.

The resulting amplification factors at 1.2 g, 1.4 g, and 1.6g for each input motion are listed in Tables 7-9 through 7-11 for the median, lower bound, and upper bound profiles, respectively. The average amplification of three input motions for the three profiles are listed in Table 7-21.

The normalized standard error was computed (eq. 5-5) on the amplification factors for each profile at 1.2 g, 1.4g, and 1.6g input PGA in order to quantify limitations on the use of the average factors due to their development from three input time histories. The amplification factors for each earthquake, their average, and the normalized standard error of each average value are all listed in Tables 7-13 through 7-21. In general the normalized SE values are about 5%.

For the development of smooth design spectra, a subsets of 30 spectral periods were chosen to represent the 153 spectral periods for each profile. The subsets are plotted in Figures 7-14, 7-15, and 7-16. Most applications in which these factors will be used include 0.075 and 0.75 sec periods; therefore the 0.07 and 0.08 sec values have been interpolated to 0.075 sec, and the 0.74 and 0.76 sec values have been interpolated to 0.75 sec (log-log interpolations).

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 44 of 196 Date: 11/06/02 Table 7-8. Spectral shape (sa/pga) of the input time histories Period Time Time Time (sec)

History 1 History 2 History 3 0.01 1.000 1.000 1.000 0.03 1.007 1.005 0.964 0.04 1217 1.226 1.207 0.05 1.433 1.433 1.371 0.06 1.557 1.561 1.531 0.07 1.734 1.749 1.623 0.08 1.870 1.821 1.761 0.09 1.982 1.902 1.836 0.10 1.995 1.958 1.897 0.11 2.052 2.046 1.924 0.12 2.051 2.073 2.003 0.13 2.182 2.143 1.940 0.14 2.149 2.184 2.104 0.15 2.196 2.225 2.167 0.16 2.192 2.234 2.168 0.17 2.277 2.272 2.209 0.18 2.273 2.320 2.211 0.19 2.283 2.321 2.221 0.20 2.300 2.328 2.243 0.21 2.341 2.314 2.239 0.22 2.359 2.320 2.218 0.23 2.289 2.335 2.231 0.24 2.327 2.327 2.263 0.25 2.361 2.306 2.181 0.26 2.345 2.281 2.247 0.27 2.290 2.269 2.222 0.28 2.262 2.274 2.268 0.29 2.273 2.278 2.238 0.30 2.202 2.260 2.125 0.31 2.287 2.216 2.185 0.32 2.218 2.174 2.125 0.33 2.164 2.146 2.050 0.34 2.091 2.133 2.066 035 2.033 2.125 2.074 0.36 2.043 2.112 2.063 037 2.071 2.092 1.979 038 2.029 2.065 2.001 0.39 2.048 2.035 1.988 0.40 2.042 2.002 1.950 0.41 2.052 1.967 1.917 0.42 1.977 1.950 1.899 0.43 2.002 1.945 1.913 0.44 1.958 1.857 1.798 0.45 1.858 1.892 1.794 0.46 1.849 1.872 1.796 OA7 1.883 1.800 1.773 OA8 1.883 1.777 1.730 0.49 1.821 1.788 1.753 0.50 1.709 1.781 1.740 0.51 1.605 1.745 1.680

Calc Number: GEO.HBIP.02.06 Rev Number- 0 Sheet Number: 45 of 196 Date: 11/06/02 Period Time Time Time (see)

History 1 History 2 History 3 0.52 1.556 1.707 1.650 0.53 1.553 1.681 1.586 0.54 1.560 1.667 1.581 0.55 1.565 1.639 1.618 0.56 1.575 1.601 1.575 0.57 1.578 1.614 1.525 0.58 1.541 1.522 1.517 0.60 1.462 1.574 1.423 0.62 1.429 1.478 1.447 0.64 1.482 1.457 1.430 0.66 1.466 1.412 1.413 0.68 1.333 1.385 1.318 0.70 1.296 1.383 1.261 0.72 1.304 1.314 1.287 0.74 1.273 1.342 1.238 0.76 1.248 1.327 1.182 0.78 1.222 1.258 1.173 0.80 1.191 1.244 1.198 0.82 1.159 1.204 1.180 0.84 1.132 1.163 1.139 0.86 1.109 1.202 1.103 0.88 1.086 1.153 1.080 0.90 1.064 1.063 1.025 0.92 1.044 1.048 0.968 0.94 1.025 1.092 0.930 0.96 1.005 1.091 0.954 0.98 0.986 1.023 0.983 1.00 0.966 0.985 0.993 1.05 0.917 0.911 0.942 1.10 0.860 0.870 0.875 1.15 0.834 0.850 0.814 1.20 0.806 0.778 0.784 1.25 0.738 0.794 0.752 1.30 0.754 0.757 0.727 1.35 0.693 0.707 0.694 1.40 0.674 0.683 0.654 1.45 0.654 0.663 0.630 1.50 0.644 0.625 0.625 1.55 0.632 0.620 0.612 1.60 0.609 0.599 0.578 1.65 0.583 0.574 0.535 1.70 0.551 0.552 0.511 1.75 0.521 0.525 0.507 1.80 0.495 0.526 0.499 1.85 0.479 0.533 0.496 1.90 0.478 0.486 0.480 1.95 0.472 0.467 0.447 2.00 0.463 0.482 0.441 2.05 0.448 0.466 0.431 2.10 0.429 0.419 0.414 2.15 0.407 0.408 0.394 2.20 0.389 0.392 0.385 2.25 0.377 0.394 0.378

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 46 of 196 Date: 11/06/02 Period Time Time Time (sec)

HIstory 1 History 2 History 3 2.30 0.366 0.386 0.367 2.35 0.356 0.367 0.353 2.40 0.347 0.357 0.334 2.50 0.329 0.333 0.327 2.60 0.312 0.314 0.304 2.70 0.295 0.300 0.290 2.80 0.280 0.280 0.279 2.90 0.267 0.276 0.272 3.00 0.255 0.269 0.262 3.10 0.245 0.259 0.245 3.20 0.235 0.247 0.225 3.30 0.224 0.233 0.212 3.40 0.216 0.218 0.211 3.50 0.210 0.206 0.199 3.60 0.203 0.204 0.188 3.70 0.202 0.182 0.178 3.80 0.199 0.190 0.170 3.90 0.191 0.198 0.172 4.00 0.181 0.194 0.169 4.10 0.169 0.176 0.149 4.20 0.160 0.158 0.151 4.30 0.148 0.161 0.154 4.40 0.152 0.153 0.152 4.50 0.154 0.146 0.146 4.60 0.150 0.136 0.137 4.70 0.139 0.138 0.125 4.80 0.124 0.145 0.119 4.90 0.123 0.142 0.117 5.00 0.121 0.133 0.114 5.10 0.118 0.122 0.107 5.20 0.113 0.114 0.103 5.40 0.101 0.109 0.103 5.60 0.094 0.106 0.089 5.80 0.088 0.094 0.083 6.00 0.083 0.093 0.081 6.20 0.078 0.085 0.078 6.40 0.075 0.079 0.075 6.60 0.078 0.074 0.073 6.80 0.077 0.072 0.068 7.00 0.075 0.074 0.063 7.20 0.070 0.072 0.062 7.40 0.068 0.068 0.057 7.60 0.065 0.064 0.051 7.80 0.061 0.059 0.048 8.00 0.057 0.053 0.048 8.50 0.044 0.047 0.046 9.00

  • 0.037 0.046 0.041 9.50 0.030 0.042 0.037 10.00 0.024 0.034 0.034

Calc Number. GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 47 of 196 Date: 11/06/02 Table 7-9. Amplification factors for the median profile Period Time Histo 1

Time Histor 2 Time Histor3 3 (sec) 1.2 1.4 1.6 1.2 1.4 6 g 1.2 1.4 1.6 0.01 0.742 0.628 0.545 0.826 0.754 0.680 0.798 0.697 0.600 0.03 0.740 0.626 0.543 0.824 0.752 0.678 0.828 0.724 0.623 0.04 0.615 0.520 0.451 0.677 0.618 0.557 0.663 0.579 0.499 0.05 0.525 0.444 0.34 0.581 0.530 0.478 0.585 0.511 0.440 0.06 0.486 0.411 0.356 0.536 0.489 0.440 0.525 0.459 0.395 0.07 0.439 0.371 0.321 0.480 0.438 0.394 0.497 0.434 0.374 0.08 0.411 0.347 0.300 0.461 0.421 0.380 0.458 0.401 0.346 0.09 0.395 0.331 0.285 0.451 0.409 0.367 0.444 0.387 0.333 0.10 0.408 0.340 0.290 0.448 0.404 0.362 0.426 0.373 0.321 0.11 0.387 0.327 0.282 0.432 0.389 0.349 0.422 0.369 0.318 0.12 0.398 0.334 0.287 0.424 0.383 0.344 0.396 0.347 0.301 0.13 0.374 0.314 0.271 0.396 0.361 0.327 0.432 0.372 0.319 0.14 0.383 0.319 0.277 0.373 0.345 0.316 0.403 0.350 0.301 0.15 0.402 0.332 0.280 0.367 0.340 0.311 0.374 0.327 0.285 0.16 0.459 0.376 0.314 0.365 0.335 0.307 0.400 0.342 0.291 0.17 0.451 0.377 0.316 0.390 0.334 0.304 0.443 0.373 0.315 0.18 0.448 0.367 0.296 0.430 0.366 0.300 0.495 0.412 0.347 0.19 0.441 0.361 0.305 0.509 0.430 0.357 0.497 0.416 0.354 0.20 0.534 0.427 0.357 0.579 0.489 0.405 0.496 0.418 0.366 0.21 0.575 0.455 0.375 0.617 0.524 0.436 0.522 0.441 0.384 0.22 0.624 0.496 0.398 0.653 0.555 0.463 0.541 0.456 0.397 0.23 0.639 0.513 0.413 0.687 0.586 0.491 0.560 0.478 0.407 0.24 0.666 0.542 0.454 0.723 0.619 0.520 0.599 0.510 0.433 0.25 0.664 0.547 0.461 0.760 0.653 0.550 0.637 0.540 0.459 0.26 0.685 0.553 0.457 0.794 0.685 0.579 0.609 0.515 0.438 0.27 0.712 0.579 0.479 0.823 0.712 0.604 0.547 0.463 0.410 0.28 0.744 0.609 0.506 0.842 0.731 0.622 0.575 0.475 0.408 0.29 0.767 0.632 0.525 0.855 0.745 0.637 0.608 0.501 0.427 0.30 0.852 0.703 0.593 0.868 0.759 0.651 0.636 0.527 0.445 0.31 0.874 0.726 0.616 0.886 0.778 0.670 0.660 0.547 0.465 0.32 0.879 0.739 0.632 0.906 0.797 0.688 0.693 0.576 0.493 0.33 0.853 0.719 0.606 0.926 0.817 0.707 0.704 0.577 0.506 0.34 0.873 0.742 0.626 0.946 0.836 0.725 0.782 0.655 0.574 0.35 0.932 0.781 0.662 0.965 0.853 0.742 0.840 0.707 0.620 0.36 0.942 0.802 0.679 0.984 0.872 0.759 0.882 0.745 0.654 0.37 0.967 0.830 0.702 1.004 0.891 0.778 0.966 0.818 0.727 0.38 1.058 0.902 0.762 1.024 0.910 0.796 1.011 0.865 0.772 0.39 1.125 0.978 0.860 1.042 0.929 0.815 0.995 0.856 0.767 0.40 1.214 1.089 0.957 1.060 0.945 0.831 1.048 0.889 0.794 0.41 1.272 1.144 1.009 1.094 0.960 0.846 1.126 0.969 0.848 0.42 1.297 1.173 1.040 1.116 0.985 0.856 1.216 1.051 0.925 0.43 1.207 1.103 0.984 1.106 0.979 0.853 1.236 1.072 0.946 0.44 1.156 1.069 0.961 1.210 1.110 0.973 1.216 1.056 0.932 0.45 1.142 1.071 0.971 1.265 1.168 1.030 1.037 0.922 0.829 0.46 1.064 1.013 0.928 1.266 1.178 1.045 1.080 0.945 0.829 0.47 0.946 0.916 0.848 1.245 1.187 1.068 1.091 0.983 0.880 0.48 0.892 0.858 0.786 1.178 1.131 1.024 1.120 1.017 0.915 0.49 0.892 0.859 0.786 1.165 1.125 1.048 1.068 0.968 0.876 0.50 0.892 0.856 0.782 1.155 l.130 1.049 1.105 0.961 0.815 0.51 0.886 0.847 0.772 1.164 1.134 1.051 1.128 0.987 0.840 0.52 0.877 0.834 0.757 1.173 1.140 1.056 1.061 0.932 0.799 0.53 0.865 0.821 0.744 1.180 1.146 1.061 1.004 0.892 0.776 0.54 0.876 0.809 0.732 1.178 1.145 1.061 1.103 0.951 0.802 0.5 0.900 0.800 0.722 1.173 1.140 1.058 1.110 0.961 0.812 056 0.931 0.826 0.713 1.184 1.135 1.041 1.123 0.974 0.825 0.57 0.972 0.867 0.734 1.133 1.085 0.977 1.134 0.976 0.820

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 48 of 196 Date: 1 1/06/02 Period Time Histo 1

Time Histo 2

Time Histo 3

(sec) 1.22

1. 4 1.6 1.2 g 1.4 1.6 g 1.2 1.4 1.6 0.58 1.026 0.922 0.784 1.139 1.093 1.022 1.139 0.983 0.830 0.60 1.021 0.933 0.804 1.150 1.109 1.044 1.155 1.000 0.853 0.62 1.074 0.92-1 0.768 1.266 1.183 1.060 1.081 0.945 0.788 0.64 1.094 0.933 0.773 1.280 1.192 1.066 1.211 1.004 0.816 0.66 1.158 0.999 0.837 1.429 1.327 1.161 1.283 1.083 0.860 0.68 1.253 1.091 0.919 1.459 1.351 1.183 1.298 1.118 0.906 0.70 1.273 1.112 0.937 1.373 1.279 1.135 1.400 1.149 0.901 0.72 1.283 1.117 0.935 1.390 1.321 1.181 1.454 1.195 0.937 0.74 1.215 1.066 0.937 1.433 1.362 1.218 1.462 1.209 0.949 0.76 1.188 1.083 0.954 1.461 1.399 1.253 1.487 1.232 1.007 0.78 1.212 1.110 0.966 1.494 IA37 1.297 1.469 1.315 1.089 0.80 1.241 1.141 1.002 1.530 1.477 1.337 1.494 1.336 1.107 0.82 1.269 1.171 1.037 1.553 1.500 1.359 1.521 1.363 1.132 0.84 1.289 1.194 1.066 1.471 1.440 1.373 1.549 1.394 1.163 0.86 1.302 1.211 1.088 1.485 1.454 1.384 1.543 1.397 1.170 0.88 1.312 1.226 1.109 1.492 1.458 1.380 1.478 1.345 1.133 0.90 1.318 1.236 1.126 1.489 1.449 1.369 1.420 1.302 1.106 0.92 1.320 1.242 1.138 1.478 IA37 1.364 1.372 1.269 1.091 0.94 1.321 1.247 1.148 1.475 1.437 1.373 1.337 1.291 1.210 0.96 1.322 1.251 1.158 1.483 1.448 1.386 1.407 1.345 1.249 0.98 1.323 1.255 1.168 1.496 1.460 1.398 1.429 1.358 1.254 1.00 1.324 1.260 1.178 1.449 1.411 1.349 1.444 1.368 1.260 1.05 1.317 1.260 1.191 1.511 1.468 1.409 1.423 1.345 1.241 1.10 1.299 1.248 1.192 1.432 1.394 1.363 1.502 1.362 1.228 1.15 1.243 1.169 1.129 1.523 1.465 1.425 1.715 1.563 1.411 1.20 1.272 1.178 1.116 1.761 1.586 1.427 1.795 1.642 1.483 1.25 1.415 1.304 1.220 1.817 1.646 1.471 1.829 1.677 1.515 1.30 1.570 1.466 1.381 1.873 1.704 1.523 1.857 1.705 1.542 1.35 1.787 1.626 1.494 1.928 1.760 1.572 1.887 1.738 1.574 1.40 1.758 1.619 1.499 2.010 1.799 1.580 1.933 1.784 1.618 IAS 1.824 1.623 1.467 2.059 1.843 1.613 1.984 1.830 1.660 1.50 1.895 1.697 1.518 2.126 1.902 1.658 2.019 1.862 1.691 1.55 1.978 1.778 1.595 2.245 2.027 1.779 2.044 1.889 1.721 1.60 2.070 1.869 1.682 2.327 2.101 1.840 2.076 1.928 1.765 1.65 2.130 1.932 1.745 2.452 2.208 1.928 2.255 1.983 1.824 1.70 2.187 1.994 1.808 2.407 2.254 2.034 2.347 2.045 1.872 1.75 2.249 2.059 1.873 2.421 2.282 2.066 2.391 2.116 1.917 1.80 2.337 2.128 1.940 2.505 2.370 2.144 2.467 2.188 2.012 1.85 2.375 2.169 2.016 2.625 2.472 2.219 2.412 2.254 2.069 1.90 2.323 2.142 2.047 2.771 2.591 2.366 2.487 2.320 2.131 1.95 2.277 2.169 2.078 2.648 2.560 2.398 2.589 2.447 2.248 2.00 2.269 2.193 2.102 2.512 2.517 2.441 2.571 2.453 2.265 2.05 2.286 2.212 2.124 2.629 2.623 2.522 2.594 2.452 2.258 2.10 2.306 2.235 2.149 2.614 2.585 2.456 2.648 2.511 2.278 2.15 2.332 2.265 2.184 2.454 2.483 2.478 2.494 2.413 2.328 2.20 2.327 2.266 2.191 2.512 2.543 2.542 2.369 2.423 2.411 2.25 2.293 2.239 2.172 2.421 2.454 2.455 2.359 2.470 2.453 2.30 2.261 2.215 2.154 2.371 2.406 2.433 2.393 2.495 2.475 2.35 2.229 2.191 2.136 2.364 2.403 2.413 2.407 2.502 2.489 2.40 2.197 2.164 2.114 2.268 2.312 2.346 2.403 2.501 2.510 2.50 2.126 2.103 2.061 2.269 2.346 2.413 2.117 2.238 2.283 2.60 2.044 2.029 1.994 2.238 2.317 2.391 2.311 2.437 2.531 2.70 1.952 1.945 1.919 2.131 2.213 2.294 2.253 2.408 2.529 2.80 1.853 1.856 1.843 2.026 2.113 2.202 2.079 2.230 2.359 2.90 1.758 1.765 1.772 1.836 1.907 1.978 1.819 1.957 2.055 3.00 1.766 1.748 1.727 1.765 1.834 1.906 1.799 1.936 2.029 3.10 1.780 1.766 1.749 1.703 1.772 1.845 1.806 1.947 2.055

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Nunber: 49 of 196 Date: 1 1/06/02 Period Time Histor I Time Histo 2 Time Histon 3 (sec) 1.2 1.4 1.6 1.2 1.4 1.6 1.2 g 1.4.

1.6 L 3.20 1.801 1.792 1.874 1.651 1.720 1.800 1.834 1.978 2.094 3.30 1.829 1.825 1.841 1.610 1.688 1.782 1.789 1.917 2.031 3.40 1.841 1.841 1.838 1.642 1.694 1.791 1.85S 1.951 2.026 3.50 1.S16 1.822 1.825 1.670 1.729 1.798 1.957 2.066 2.154 3.60 1.799 1.811 1.820 1.510 1.585 1.677 1.832 1.943 2.036 3.70 1.716 1.734 1.751 1.577 1.656 1.751 1.672 1.734 1.823 3.80 1.643 1.670 1.697 1.538 1.573 1.609 1.625 1.690 1.742 3.90 1.599 1.638 1.675 1.529 1.570 1.617 1.573 1.643 1.702 4.00 1.580 1.629 1.670 1.546 1.596 1.655 1.525 1.609 1.684 4.10 1.570 1.623 1.667 1.560 1.621 1.692 1.505 1.615 1.716 4.20 1.540 1.596 1.641 1.506 1.573 1.650 1.368 1.455 1.512 4.30 1.525 1.584 1.631 1.365 1.406 1.456 1.331 1.418 1.478 4.40 1.355 1.410 1.454 1.358 1.405 1.463 1.315 1.403 1.466 4.50 1.280 1.318 1.360 1.293 1.341 1.403 1.315 1.406 1.473 4.60 1.280 1.316 1.356 1.297 1.317 1.381 1.363 1.423 1.502 4.70 1.280 1.316 1.354 1.394 1.403 1.411 1.475 1.493 1.574 4.80 1.280 1.316 1.354 1.397 1.416 1.436 1.414 1.462 1.560 4.90 1.267 1.295 1.326 1.401 1.430 1.461 1.419 1.389 1.485 5.00 1.261 1.290 1.322 1.405 1.443 1.485 1.411 1.384 1.398 5.10 1.262 1.291 1.324 1.401 1.446 1.497 1.439 1.416 1.387 5.20 1.270 1.298 1.329 1.385 1.434 1.490 1.503 1.523 1.539 5.40 1.303 1.332 1.362 1.303 1.356 1.417 1507 1.544 1.574 5.60 1.252 1.283 1.313 1.176 1.235 1.304 1.295 1.348 1.393 5.80 1.222 1.251 1.282 1.290 1.315 1.337 1.290 1.277 1.255 6.00

. 1.221 1.248 1.279 1.358 1.388 1.420 1.293 1.293 1.281 6.20 1.218 1.242 1.271 1.301 1.339 1.381 1.293 1.307 1.314 6.40 1.201 1.224 1.251 1.338 1.320 1.310 1.311 1.347 1.366 6.60 1.157 1.177 1.197 1255 1.257 1.283 1.310 1.355 1.382 6.80 1.150 1.170 1.190 1.177 1.184 1.211 1.270 1.321 1.358 7.00 1.142 1.161 1.181 1.136 1.154 1.171 1.349 1.358 1.363 7.20 1.132 1.150 1.169 1.109 1.114 1.120 1.365 1.389 1.407 7.40 1.135 1.150 1.166 1.151 1.161 1.173 1.253 1.293 1.324 7.60 1.135 1.149 1.166 1.126 1.120 1.108 1.284 1.331 1.370 7.80 1.133 1.147 1.163 1.171 1.166 1.157 1.244 1.265 1.306 8.00 1.130 1.145 1.161 1.216 1.214 1.207 1.126 1.169 1.210 8.50 1.131 1.128 1.139 1.080 1.093 1.104 1.145 1.133 1.113 9.00 1.161 1.163 1.164 1.136 1.160 1.188 1.191 1.196 1.194 9.50 1.151 1.159 1.164 1.234 1.243 1.254 1.182 1.180 1.187 10.00 1.180 1.189 1.201 1.325 1.340 1.360 1.215 1.215 1.213

Calc Number. GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 50 of 196 Date: 11/06/02 Table 7-10. Amplification factors for the lower bound profile Period Time Histor 1 TmeHistory 2 imeHistory 3 (sec) 12g 1.4g 1.6g 1.22 1.4 1.6g _

1.2 1.4g 1.62 0.01 0.402 0.352 0.336 0.511 0.435 0.402 0.496 0.442 0.412 0.03 0.400 0.350 0.334 0.509 0.433 0.400 0.515 0.459 0.428 0.04 0.332 0.290 0.277 0.418 0.356 0.328 0.412 0.368 0.342 0.05 0.283 0.247 0.235 0.359 0.305 0.281 0.364 0.324 0.302 0.06 0.261 0.228 0.217 0.331 0.281 0.259 0.327 0.291 0.271 0.07 0.235 0.205 0.195 0.296 0.251 0.232 0.309 0.276 0.257 0.08 0.219 0.191 0.182 0.285 I 0.242 0.223 0.286 0.255 0.237 0.09 0.209 0.180 0.172 0.275 0.232 0.214 0.275 0.245 0.228 0.10 0.209 0.180 0.171 0.270 0.227 0.209 0.266 0.238 0.222 0.11 0.207 0.175 0.167 0.260 0.218 0.201 0.264 0.235 0.220 0.12 0.210 0.176 0.168 0.256 0.217 0.200 0.251 0.226 0.211 0.13 0.200 0.167 0.157 0.244 0.211 0.194 0.265 0.236 0.220 0.14 0211 0.172 0.161 0.239 0.204 0.189 0.249 0.222 0.206 0.15 0.226 0.173 0.160 0.235 0202 0.187 0.237 0.212 0.199 0.16 0.236 0.181 0.163 0.234 0.197 0.184 0.244 0.216 0.200 0.17 0.228 0.179 0.161 0.238 0.211 0.191 0.260 0.226 0.205 0.18 0.232 0.187 0.156 0.240 0.213 0.193 0.283 0.243 0.218 0.19 0.232 0.180 0.162 0.260 0.221 0.199 0.287 0.246 0.221 0.20 0.283 0.212 0.166 0.293 0.233 0.200 0.286 0.233 0.213 0.21 0.299 0.225 0.173 0.317 0.252 0.214 0.303 0.245 0.214 0.22 0.296 0.219 0.188 0.339 0.268 0.227 0.316 0.264 0.236 0.23 0.307 0.248 0211 0.359_

0.284 0.239 0.339 0.286 0.252 0.24 0.343 0.275 0.232 0.382 _ 0.301 0.253 0.361 0.302 0.262 0.25 0.356 0.278 0231 0.406 0.320 0.268 0.384 0.318 0.275 0.26 0.391 0.304 0.241 0.429 0.338 0.283 0.367 0.303 0.261 0.27 0.411 0.325 0.261 0.449 0.353 0.296 0.362 0.322 0.278 0.28 0.419 0.333 0.274 0.465 0.366 0.306 0.410 0.362 0.312 0.29 0.437 0.348 0.287 0.477 0.376 0.315 0.424 0.377 0.328 0.30 OA60 0.368 0.306 OA91 0.386 0.324 0.437 0.391 0.344 0.31 0.457 0.368 0.306 0.506 0.398 0.334 0.410 0.355 0.317 0.32-0.488 0.394 0.330 0.521 0.411 0.345 0.447 0.371 0.300 0.33 0.510 0.413 0.348 0.537 0.423 0.356 0.464 0.387 0.320 0.34 0.531 0.433 0.367 0.552 0.435 0.365 0.476 0.399 0.331 0.35 0.553 0.453 0.386 0.566 0.447 0.375 0.503 0.417 0.340 0.36 0.572 0.469 0.399 0.582 0.459 0.386 0.539 0.448 0.367 0.37 0.588 0.483 0.411 0.599 0.472 0.396 0.566 0.473 0.418 0.38 0.611 0.502 0.429 0.616 0.485 0.408 0.602 0.500 0.419 0.39 0.632 0.506 0.434 0.633 0.499 0.419 0.607 0.504 0.418 0.40 0.712 0.534 0.441 0.650 0.512 0.429 0.631 0.532 0.451 0.41 0.764 0.573 0.472 0.665 0523 0.439 0.663 0.545 0.459 0.42 0.809 0.608 0.506 0.670 0.527 0.442 0.725 0.586 0.494 0.43 0.790 0.598 0.505 0.674 0.524 0.439 0.741 0.597 0.503 0.44 0.798 0.619 0.525 0.753 0.576 0.492 0.732 0.606 0.525 0.45 0.834 0.672 0.573 0.829 0.654 0.559 0.762 0.648 0.566 0.46 0.827 0.699 0.597 0.902 0.716 0.613 0.813 0.676 0.572 0.47 0.832 0.704 0.603 0.931 0.758 0.669 0.875 0.729 0.598 0.48 0.836 0.707 0.609 0.967 0.821 0.725 0.923 0.773 0.636 0.49 0.835 0.708 0.614 0.978 0.832 0.735 0.902 0.764 0.656 0.50 0.827 0.706 0.619 0.967 0.825 0.732 0.903 0.780 0.680 0.51 0.816 0.705 0.627 0.960 0.823 0.733 0.923 0.813 0.715

Calc Number: GEO.HBIP.02.06 Rev Number 0 Sheet Number 51 of 196 Date: 11/06/02 Period Time Histo 1

Time Histo 2 Time Histor 3 (sec) 1.2 1.4 g 1.6 g 1.2 1.4 1.6 1.2 g 1.4 1.6 0.52 0.811 0.712 0.642 0.960 0.827 0.738 0.897 0.781 0.687 0.53 0.814 0.724 0.660 0.965 0.834 0.747 0.880 0.776 0.716 0.54 0.819 0.737 0.675 0.967 0.838 0.750 0.900 0.830 0.780 0.55 0.826 0.750 0.692 0.966 0.838 0.751 0.906 0.832 0.778 0.56 0.835 0.766 0.712 0.951 0.824 0.749 0.914 0.837 0.781 0.57 0.849 0.787 0.735 0.883 0.785 0.734 0.899 0.832 0.803 0.58 0.867 0.810 0.778 0.915 0.812 0.742 0.885 0.834 0.808 0.60 0.797 0.791 0.805 0.974 0.874 0.804 0.904 0.852 0.825 0.62 0.722 0.730 0.746 0.976 0.883 0.815 0.798 0.743 0.727 0.64 0.711 0.688 0.707 0.893 0.817 0.771 0.807 0.742 0.725 0.66 0.711 0.703 0.725 0.896 0.828 0.788 0.781 0.715 0.694 0.68 0.764 0.741 0.761 0.885 0.792 0.739 0.752 0.686 0.661 0.70 0.790 0.736 0.750 0.816 0.728 0.684 0.765 0.715 0.705 0.72 0.793 0.727 0.739 0.836 0.721 0.650 0.789 0.691 0.684 0.74 0.816 0.728 0.708 0.838 0.722 0.652 0.806 0.714 0.666 0.76 0.829 0.741 0.691 0.842 0.729 0.662 0.816 0.729 0.684 0.78 0.839 0.749 0.705 0.923 0.775 0.674 0.816 0.710 0.658 0.80 0.848 0.758 0.714 0.968 0.818 0.715 0.836 0.727 0.665 0.82 0.858 0.767 0.723 1.022 0.866 0.759 0.868 0.755 0.689 0.84 0.863 0.772 0.727 1.106 0.937 0.823 0.910 0.791 0.722 0.86 0.874 0.774 0.728 1.098 0.934 0.824 0.939 0.818 0.744 0.88 0.902 0.775 0.729 1.098 0.945 0.839 0.936 0.818 0.745 0.90 0.927 0.789 0.729 1.122 0.975 0.869 0.941 0.828 0.754 0.92 0.949 0.811 0.731 1.152 0.999 0.889 0.954 0.844 0.769 0.94 0.971 0.832 0.748 1.160 0.999 0.886 1.046 0.864 0.786 0.96 0.992 0.854 0.766 1.156 0.995 0.884 1.084 0.885 0.768 0.98 1.026 0.879 0.785 1.156 1.003 0.896 1.091 0.892 0.767 1.00 1.060 0.915 0.810 1.166 0.993 0.887 1.097 0.897 0.771 1.05 1.121 0.989 0.883 1.253 1.080 0.970 1.137 0.980 0.864 1.10 1.207 1.109 1.011 1.254 1.134 1.009 1.110 1.016 0.951 1.15 1.208 1.131 1.047 1.343 1.204 1.079 1.255 1.157 1.083 1.20 1.143 1.114 1.062 1.348 1.216 1.162 1.312 1.205 1.128 1.25 1.135 1.115 1.129 1.219 1.188 1.156 1.329 1.220 1.144 1.30 1.277 1.249 1.240 1.228 1.203 1.179 1.345 1.247 1.208 1.35 1.337 1.296 1.274 1.243 1.216 1.193 1.366 1.257 1.213 1.40 1.288 1.208 1.159 1.261 1.228 1.205 1.394_

1.282 1.207 1.45 1.256 1.176 1.123 1.249 1.213 1.191 1.418 1.305 1.230 1.50 1.255 1.171 1.110 1.302 1.252 1.251 1.437 1.325 1.252 1.55 1.302 1.211 1.143 1.337 1.254 1.220 1.460 1.351 1.279 1.60 1.381 1.283 1.208 1.309 1.217 1.164 1.497 1.390 1.317 1.65 1.454 1.352 1.271 1.338 1.249 1.201 1.544 _

1.435 1.360 1.70 1.534 1.428 1.342 1.386 1.265 1.200 1.576 1.463 1.386 1.75 1.618 1.508 1.417 1.384 1.259 1.194 1.599 1.484 1.406 1.80 1.709 1.593 1.497 1.392 1.258 1.190 1.666 1.547 1.467 1.85 1.784 1.663 1.564 1.406 1.232 1.165 1.706 1.588 1.510 1.90 1.811 1.688 1.590 1.623 1.414 1.299 1.758 1.645 1.571 1.95 1.838 1.716 1.619 1.747 1.517 1.397 1.862 1.751 1.678 2.00 1.861 1.739 1.644 1.824 1.646 1.534 1.851 1.743 1.674 2.05 1.884 1.764 1.669 1.907 1.736 1.629 1.856 1.741 1.672 2.10 1.913 1.794 1.700 2.021 1.774 1.680 1.938 1.779 1.691 2.15 1.954 1.834 1.739 2.067 1.848 1.735 2.033 1.882 1.762

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 52 of 196 Date: 11/06102 Period Time Histon1 Time Histo 2

Time Histo 3

(sec) 1.2 e 1.4 a g

Mg 1.6.z 142

i.

1.4 1.6 2.20 1.973 1.854 1.758 2.157 1.968

_- 1.851 2.124 1.930 1.819 2.25 1.969 1.851 1.756 2.251 2.024 1.878 2.172 1.968 1.867 2.30 1.965 1.849 1.754 2.218 2.037 1.923 2.215 2.027 1.936 2.35 1.959 1.845 1.751 2.281 2.145 2.027 2.269 2.111 2.027 2.40 1.949 1.839 1.746 2.322 2.187 2.070 2.329 2.215 2.133 2.50 1.919 1.817 1.730 2.413 2.282 2.167 2.264 2.177 2.103 2.60 1.881 1.793 1.715 2.424 2.301 2.192 2.653 2.509 2.343 2.70 1.844 1.777 1.714 2.415 2.368 2.292 2.692 2.594 2.460 2.80 1.892 1.896 1.842 2.308 2.237 2.227 2.646 2.571 2.442 2.90 1.962 2.038 2.034 2.353 2.412 2.393 2.372 2.391 2.349 300 2.054 2.149 2.172 2.282 2.349 2.351 2.287 2.306 2.265 3.10 2.165 2.327 2.419 2.251 2.372 2.434 2.243 2.228 2.203 3.20 2.307 2.468 2.564 2.114 2.223 2.272 2.297 2.282 2.283 3.30 2.270 2.428 2.529 2.079 2.097 2.090 2.235 2.312 2.364 3.40 2.065 2.217 2.317 2.102 2.141 2.211 2.282 2.376 2.443 3.50 1.959 2.060 2.125 2.087 2.195 2.283 2.422 2.486 2.563 3.60 1.965 2.078 2.154 1.975 1.999 2.089 2.311 2.380 2.439 3.70 1.896 2.016 2.100 2.066 2.093 2.168 2.094 2.169 2.229 3.80 1.831 1.960 2.055 1.931 1 2.017 2.074 1.948 2.030 2.094 3.90 1.796 1.938 2.044 1.823 1.941 2.023 1.900 1.966 2.025 4.00 1.801 1.941 2.053 1.873 1.929 2.013 1.923 2.004 2.073 4.10 1.806 1.946 2.063 1.954 2.021 2.069 2.007 2.098 2.174 4.20 1.786 1.923 2.041 1.931 2.002 2.050 1.817 1.919 1.991 4.30 1.783 1.914 2.035 1.636 1.719 1.802 1.728 1.832 1.909 4.40 1.598 1.705 1.817 1.678 1.761 1.843 1.666 1.775 1.859 4.50 1.548 1.641 1.730 1.646 1.729 1.808 1.631 1.746 1.836 4.60 1.540 1.632 1.721 1.614 1.688 1.768 1.699 1.745 1.841 4.70 1.530 1.615 1.703 1.576 1.663 1.720 1.793 1.846 1.892 4.80 1.531 1.615 1.694 1.493 1.591 1.659 1.790 1.847 1.891 4.90 1.482 1.553 1.606 1.538 1.551 1.601 1.719 1.778 1.824 5.00 1.479 1.552 1.611 1.602 1.623 1.641 1.634 1.694 1.743 5.10 1.481 1.559 1.622 1.644 1.671 1.693 1.589 1.653 1.706 5.20 1.485 1.565 1.633 1.657 1.688 1.712 1.641 1.685 1.728 5.40 1.517 1.599 1.674 1.609 1.649 1.678 1.708 1.764 1.820 5.60 1.465 1.546 1.622 1.542 1.602 1.645 1.551 1.616 1.682 5.80 1.408 1.449 1.526 1.431 1.470 1.534 1.306 1.351 1.391 6.00 1.407 1A55 1.484 1.543 1.588 1.623 1.261 1.271 1.295 6.20 1.399 1.451 1.486 1.538 1.595 1.640 1.316 1.316 1.327 6.40 1.377 1.432 1.471 1.387 1.413 1.439 1.392 1.395 1.406 6.60 1.284 1.325 1.362 1.379 1.419 1.449 1.431 1.441 1.455 6.80 1.276 1.318 1.358 1.309 1.350 1.382 1.433 1.451 1.472 7.00 1.265 1.309 1.349 1.340 1.392 1.427 1.412 1.432 1.454 7.20 1.249 1.292 1.334 1.238 1.302 1.348 1.484 1.514 1.546 7.40 1.230 1.255 1.281 1.204 1.238 1.261 1.414 1.454 1.496 7.60 1.234 1.261 1.287 1.154 1.205 1.234 1.450 1.466 1.485 7.80 1.235 1.263 1.290 1.168 1.211 1.255 1.443 1.483 1.508 8.00 1.235 1.265 1.292 1.219 1.259 1.302 1.350 1.393 1.423 8.50 1.216 1.250 1.281 1.175 1.202 1.224 1.050 1.102 1.142 9.00 1.203 1.241 1.282 1.270 1.279 1.289 1.157 1.130 1.110 9.50 1.197 1.232 1.277 1.279 1.278 1.280 1.207 1.188 1.182 10.00 1.264 1.269 1.264 1.421 1.432 1.444 1.248 1.262 1.281

Calc Number: GEO.HBIP.02.06 Rev Number 0 Sheet Number: 53 of 196 Date: 11/06/02 Table 7-11. Amplification factors for the upper bound profile Period

_a__

quae I Earthquake2 Eathouske 3 (see) 1.2I 1.4g 1.6 1.2 l 1A g l1.6.

1.2g _

A g 1.6 0.01 0.928 0.876 0.815 0.786 0.782 0.782 0.950 0.879 0.842 0.03 0.928 0.874 0.813 0.785 0.779 0.780 0.990 0.915 0.875 0.04 0.773 0.727 0.676 0.645 0.639 0.640 0.794 0.733 0.700 0.05 0.664 0.621 0.577 0.555 0.548 0.549 0.702 0.647 0.618 0.06 0.618 0.576 0.535 0.510 0.505 0.504 0.634 0.583 0.555 0.07 0.568 0.522 0.484 0.458 0.449 0.451 0.604 0.553 0.526 0.08 0.553 0.491 0.453 0.434 0.441 0.437 0.559 0.511 0.484 0.09 0.531 0.486 0.443 0.482 0.427 0.430 0.551 0.500 0.472 0.10 0.554 0.502 0.456 0.510 0.448 0.416 0.558 0.497 0.461 0.11 0.581 0.498 0.433 0.510 0.450 0.394 0.555 0.497 0.458 0.12 0.611 0.522 0.452 0.541 0.478 0.417 0.557 0.486 0.439 0.13 0.526 0.457 0.404 0.561 0.498 0.436 0.540 0.494 0.472 0.14 0.609 0.519 0.448 0.574 0.470 0.424 0.470 0.439 0.425 0.15 0.671 0.562 0.487 0.609 0.484 0.408 0.512 0.446 0.409 0.16 0.700 0.625 0.548 0.650 0.520 0.416 0.600 0.489 0.438 0.17 0.685 0.588 0.527 0.689 0.557 0.447 0.603 0.516 0.488 0.18 0.691 0.597 0.507 0.724 0.589 0.477 0.636 0.584 0.547 0.19 0.797 0.666 0.536 0.811 0.703 0.591 0.650 0.578 0.544 0.20 0.863 0.733 0.600 0.903 0.789 0.672 0.669 0.593 0.534 0.21 0.863 0.743 0.630 0.939 0.828 0.713 0.703 0.622 0.558 0.22 0.931 0.804 0.686 0.971 0.863 0.749 0.737 0.633 0.568 0.23 0.951 0.820 0.702 1.000 0.895 0.782 0.765 0.663 0.605 0.24 0.956 0.822 0.706 1.026 0.925 0.814 0.844 0.728 0.656 0.25 1.015 0.858 0.726 1.053 0.957 0.848 0.956 0.805 0.708 0.26 1.115 0.867 0.745 1.076 0.983 0.877 0.980 0.807 0.692 0.27 1.179 0.926 0.768 1.090 1.003 0.900 0.961 0.803 0.670 0.28 1.192 0.996 0.840 1.125 1.009 0.910 1.115 0.931 0.776 0.29 1.282 1.114 0.932 1.098 1.007 0.913 1.135 0.958 0.809 0.30 1.266 1.142 1.021 1.073 0.998 0.911 1.155 0.983 0.840 0.31 1.243 1.155 1.033 1.060 0.992 0.912 1.146 0.983 0.825 0.32 1.244 1.152 1.027 1.047 0.986 0.915 1.139 0.987 0.858 0.33 1.138 1.050 0.935 1.038 0.983 0.921 1.121 0.981 0.852 0.34 1.112 0.996 0.896 1.032 0.989 0.964 1.121 1.019 0.921 0.35 1.109 0.995 0.902 1.029 0.987 0.956 1.162 1.058 0.921 0.36 1.101 0.995 0.913 1.029 0.991 0.948 1.061 1.027 0.945 0.37 1.108 1.012 0.939 1.029 0.996 0.958 1.101 1.097 1.058 0.38 1.129 1.038 0.970 1.027 0.999 0.966 1.095 1.091 1.057 0.39 1.107 1.024 0.964 1.022 0.999 0.972

-1.089 1.091 1.049 0.40 1.098 1.025 0.993 1.014 0.996 0.974 1.016 1.029 1.026 0.41 1.046 1.028 1.022 1.000 0.988 0Q973 1.001 1.022 1.025 0.42 1.016 1.014 1.023 0.970 0.963 0.955 1.024 1.029 1.055 0.43 0.919 0.910 0.932 0.924 0.924 0.923 1.028 1.038 1.056 0.44 0.914 0.857 0.870 0.907 0.912 0.919 1.032 1.047 1.051 0.45 1.001 0.893 0.857 0.889 0.831 0.845 0.963 0.925 0.922 0.46 1.047 0.902 0.862 0.955 0.878 0.864 1.019 0.977 0.969 0.47 1.059 0.917 0.845 1.022 0.923 0.866 1.041 0.997 0.987 0.48 1.071 0.933 0.841 1.043 0.956 0.897 1.049 1.002 0.989 0.49 1.084 0.951 0.859 1.082 0.996 0.940 1.049 1.001 0.984 0.50 1.102 0.972 0.879 1.094 1.009 0.958 1.095 1.025 1.007 0.51 1.125 0.996 0.901 1.112 1.023 0.974 1.181 1.070 1.014

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 54 of 196 Date: 11/06/02 Period Time Histo I

Time Histo 2

Time Histon 3 (see) 1.2 1.4 1.6 1.2 1.4 1.6 g 1.2 g 1.4 1.6 g 0.52 1.152 1.020 0.921 1.173 1.046 0.989 1.171 1.070 0.991 0.53 1.173 1.039 0.936 1.222 1.097 1.006 1.235 1.144 1.074 0.54 1.191 1.054 0.948 1.254 1.133 1.043 1.312 1.220 1.157 0.55 1.210 1.071 0.963 1.275 1.159 1.073 1.331 1.235 1.151 0.56 1.233 1.089 1.000 1.274 1.164 1.085 1.441 1.341 1.251 0.57 1.303 1.176 1.049 1-201 1.106 1.038 1.502 1.402 1.313 0.58 1.458 1.326 1.191 1.285 1.175 1.085 1.483 1.387 1.303 0.60 1.597 1.472 1.349 1.360 1.230 1.121 1.473 1.382 1.304 0.62 1.622 1.549 1.445 1.362 1.308 1.247 1.371 1.282 1.199 0.64 1.579 1.522 1.434 1.371 1.319 1.259 1.442 1.400 1.334 0.66 1.540 1.495 1.418 1.448 1.413 1.375 1.434 1.399 1.349 0.68 1.525 1.491 1.438 1.490 1.456 1.417 1.414 1.380 1.340 0.70 1.493 1.467 1.424 1.404 1.363 1.328 1.A67 IA55 1.444 0.72 1.468 1.454 1.421 1.427 1.368 1.319 1.558 1.540 1.521 0.74 1.481 1.390 1.353 1.436 1.381 1.338 1.585 1.562 1.538 0.76 1.501 1.412 1.333 1 A61 1.410 1.369 1.613 1.590 1.566 0.78 1.514 1.424 1.346 1.A88 1.435 1.392 1.542 1.523 1.500 0.80 1.526 1.437 1.358 1.502 1.453 1.413 IA06 1.391 1.373 0.82 1.538 1.449 1.371 1.501 1.458 1.423 1.360 1.364 1.373 0.84 1.542 1.453 1.375 1.471 1.391 1.344 1.361 1.370 1.385 0.86 1.540 1.452 1.377 1A87 1.409 1.362 1.398 1.343 1.363 0.88 1.537 1.452 1.388 1.513 1.436 1.386 1.412 1.331 1.288 0.90 1.552 1.463 1.395 1.550 1.468 1.411 1.430 1.341 1.276 0.92 1.568 1.472 1.400 1.574 1.486 1.425 1.446 1350 1.278 0.94 1.585 1A82 1.406 1.578 1.491 1.430 1.607 1.506 1.427 0.96 1.605 1.494 1.412 1.584 1.501 1.441 1.672 1.574 1.497 0.98 1.627 1.509 1 A21 1.603 1.522 1.462 1.687 1.595 1.519 1.00 1.650 1.525 1.432 1.574 1.A93 1.432 1.701 1.612 1.539 1.05 1.759 1.570 1.453 1.712 1.603 1.532 1.688 1.584 1.518 1.10 1.891 1.668 1.501 1.802 1.660 1.553 1.937 1.810 1.692 1.15 1.982 1.752 1.574 1.989 1.831 1.706 2.123 2.009 1.905 1.20 2.113 1.869 1.677 2.378 2.236 2.106 2.045 -

1.974 1.926 1.25 2.161 1.946 1.794 2.343 2.221 2.110 2.040 1.991 1.948 1.30 2.251 2.081 1.930 2.387 2.257 2.133 2.208 2.017 1.971 1.35 2.536 2.378 2.217 2.537 2.423 2.300 2.460 2.257 2.068 1.40 2.706 2.564 2.390 2.586 2.488 2.375 2.541 2.362 2.179 IA5 2.688 2.585 2.440 2.597 2.513 2.410 2.655 2.503 2.408 1.50 2.656 2.585 2.465 2.640 2.565 2.470 2.372 2.300 2.221 1.55 2.672 2.620 2.514 2.497 2.444 2.407 2.232 2.206 2.173 1.60 2.699 2.662 2.570 2.489 2.517 2.509 2.335 2.348 2.328 1.65 2.669 2.694 2.663 2.634 2.667 2.662 2.617 2.640 2.623 1.70 2.635 2.724 2.719 2.607 2.640 2.633 2.663 2.696 2.690 1.75 2.575 2.685 2.703 2A29 2.463 2.462 2.602 2.649 2.659 1.80 2.514 2.585 2.616 2.283 2.332 2.386 2.572 2.621 2.642 1.85 2.470 2.537 2.577 2.325 2.421 2.492 2.410 2.463 2.486 1.90 2.378 2.438 2.460 2.459 2.566 2.645 2.434 2.468 2.494 1.95 2.286 2.354 2.382 2.319 2.423 2.501 2.529 2.570 2.600 2.00 2.177 2.252 2.288 2.021 2.132 2.228 2.416 2.459 2.491 2.05 2.110 2.173 2.215 1.967 2.101 2.224 2.314 2.373 2.426 2.10 2.115 2.182 2.227 2.023 2.109 2.227 2.224 2.310 2.392 2.15 1 2.123 2.194 2.244 2.052 2.115 2.177 2.112 2.198 2.278

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 55 of 196 Date: 11/06/02 Period Time Histo I

Time Histo 2

Time History 3 (sec) 12 1.4 g 1.6 I 12 X 1.4 g 1.6 1.2 2 1.4 g 1.6 X 2.20 2.099 2.174 2.227 2.088 2.157 2.224 1.978 2.059 2.130 2.25 2.045 2.124 2.180 1.995 2.067 2.135 1.882 1.968 2.045 2.30 1.991 2.072 2.132 1.934 2.009 2.080 1.810 1.902 1.985 2.35 1.935 2.019 2.082 1.904 1.985 2.061 1.771 1.857 1.947 2.40 1.877 1.964 2.031 1.801 1.884 1.962 1.802 1.854 1.931 2.50 1.756 1.851 1.927 1.807 1.876 1.947 1.607 1.656 1.730 2.60 1.656 1.741 1.825 1.773 1.843 1.915 1.794 1.864 1.938 2.70 1.654 1.683 1.722 1.672 1.742 1.814 1.677 1.756 1.842 2.80 1.652 1.681 1.700 1.568 1.639 1.711 1.545 1.619 1.696 2.90 1.649 1.680 1.700 1.489 1.534 1.589 1.438 1.459 1.494 3.00 1.647 1.679 1.702 1.430 1.478 1.531 1.458 1.477 1.505 3.10 1.647 1.683 1.707 1.477 1.510 1.541 1.506 1.525 1.547 3.20 1.653 1.691 1.718 1.417 1.460 1.500 1.556 1.576 1.599 3.30 1.663 1.704 1.734 1.324 1.360 1.402 1.521 1.543 1.566 3.40 1.656 1.700 1.734 1.383 1.432 1.477 1.554 I1.582 1.616 3.50 1.615 1.662 1.698 1.355 1.413 1.468 1.629 1.662 1.701 3.60 1.581 1.630 1.670 1.260 1.290 1.326 1.503 1.540 1.581 3.70 1.488 1.538 1.579 1.399 1.427 1.450 1.352 1.401 1.451 3.80 1.405 1.456 1.499 1.372 1.404 1.431 1.307 1.355 1.405 3.90 1.344 1.397 1.442 1.337 1.375 1.407 1.258 1.305 1.354 4.00 1.324 1.351 1.400 1.317 1.362 1.401 1.218 1.247 1.296 4.10 1.335 1.367 1.383 1.297 1.348 1.393 1.339 1.357 1.376 4.20 1.322 1.360 1.381 1.227 1.280 1.328 1.149

_1.167 1.186 4.30 1.311 1.355 1.382 1.207 1.230 1.254 1.076 1.082 1.112 4.40 1.159 1.203 1.234 1.201 1.223 1.246 1.142 1.124 1.111 4.50 1.155 1.170 1.186 1.173 1.190 1.206 1.206 1.191 1.180 4.60 1.157 1.173 1.189 1.202 1.220 1.235 1.265 1.277 1.295 4.70 1.157 1.174 1.190 1.281 1.305 1.326 1.340 1.361 1.383 4.80 1.163 1,173 1.190 1.254 1.283 1.309 1.368 1.381 1.392 4.90 1.184 1.188 1.196 1.225 1.259 1.291 1.359 1.374 1.387 5.00 1.172 1.181 1.190 1.200 1.239 1.275 1.340 1.356 1.371 5.10 1.170 1.183 1.194 1.177 1.217 1.257 1.354 1.373 1.391 5.20 1.169 1.185 1.199 1.151 1.192 1.233 1.361 1.382 1.405 5.40 1.183 1.203 1.220 1.075 1.111 1.150 1.321 1.349 1.378 5.60 1.184 1.190 1.193 1.063 1.050 1.039 1.210 1.205 1.222 5.80 1.172 1.182 1.189 1.228 1.228 1.230 1.234 1.246 1.255 6.00 1.158 1.173 1.185 1.272 1.280 1.288 1.200 1.219 1.235 6.20 1.141 1.161 1.177 1.244 1.243 1.237 1.176 1.198 1.218 6.40 1.115 1.137 1.156 1.339 1.346 1.349 1.156 1.179 1.204 6.60 1.088 1.099 1.110 1.217 1.231 1.242 1.201 1.201 1.200 6.80 1.083 1.093 1.104 1.093 1.109 1.119 1.222 1.228 1.232 7.00 1.080 1.088 1.098 1.066 1.075 1.086 1.245 1.261 1.278 7.20 1.086 1.096 1.104 1.063 1.071 1.079 1.225 1.247 1.269 7.40 1.080 1.092 1.102 1.085 1.097 1.108 1.263 1.251 1.236 7.60 1.074 1.085 1.097 1.103 1.109 1.113 1.327 1.325 1.320 7.80 1.069 1.079 1.090 1.132 1.141 1.148 1.239 1.250 1.257 8.00 1.069 1.076 1.086 1.162 1.174 1.184 1.078 1.082 1.084 8.50 1.104 1.113 1.120 1.037 1.030 1.031 1.139 1.139 1.139 9.00 1.099 1.113 1.126 1.077 1.082 1.088 1.150 1.157 1.163 9.50 1.062 1.078 1.095 1.173 1.1 84 1.195 1.163 1.170 1.174 10.00 1.038 1.056 1.083 1.230 1.248 1.264 1.143 1.159 1173

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 56 of 196 Date: 11/06/02 Table 7-12. Average amplification factors for the median, lower bound, and upper bound profiles analyzed Period (sec)

Median Profile Lower Bound Profile Upper Bound Profile 1.2 r 1.4 I 1.6w i 1.2,

1. 4a 1-6 1.2 1 1.4i a

1.6 g 0.01 0.788 0.693 0.608 0.470 0.410 0.383 0.888 0.846 0.813 0.03 0.797 0.701 0.615 0.475 0.414 0.387 0.901 0.856 0.822 0.04 0.652 0.573 0.502 0.388 0.338 0.316 0.738 0.700 0.672 0.05 0.563 0.495 0.434 0.335 0.292 0.273 0.641 0.605 0.581 0.06 0.516 0.453 0.397 0.306 0.267 0.249 0.588 0.555 0.531 0.07 0.472 0.414 0.363 0.280 0.244 0.228 0.543 0.508 0.487 0.08 0.443 0.390 0.342 0.263 0.229 0.214 0.515 0.481 0.458 0.09 0.430 0.376 0.329 0.253 0.219 0.205 0.521 0.471 0.448 0.10 OA27 0.372 0.324 0.248 0.215 0.201 0.541 0.483 0.444 0.11 OA13 0.362 0.316 0.243 0.209 0.196 0.549 0.482 0.428 0.12 0.406 0.355 0.311 0.239 0.206 0.193 0.570 0.495 0.436 0.13 0.401 0.349 0.306 0.237 0.205 0.190 0.542 0.483 0.438 0.14 0.386 0.338 0.298 0.233 0.199 0.185 0.551 0.476 0.432 0.15 0.381 0.333 0.292 0.232 0.196 0.182 0.597 OA97 0.435 0.16 0.408 0.351 0.304 0.238 0.198 0.182 0.650 0.545 0.468 0.17

.OA28 0.361 0.312 0.242 0.205 0.186 0.659 0.554 0.487 0.18 OA58 0.382 0.315 0.252 0.214 0.189 0.684 0.590 0.511 0.19 0.482 0.403 0.339 0.260 0.216 0.194 0.753 0.649 0.557 0.20 0.536 0.445 0.376 0.287 0.226 0.193 0.812 0.705 0.602 0.21 0.571 OA73 0.399 0.306 0.241 0.200 0.835 0.731 0.634 0.22

- 0.606 0.502 0.419 0.317 0.250 0.217 0.880 0.767 0.668 0.23 0.628 0.526 0.437 0.335 0.273 0.234 0.905 0.793 0.696 0.24 0.663 0.557 0.469 0.362 0.293 0.249 0.942 0.825 0.725 0.25 0.687 0.580 0.490 0.382 0.305 0.258 1.008 0.873 0.760 0.26 0.696 0.584 0.491 0.396 0.315 0.262 1.057 0.886 0.771 0.27 0.694 0.585 0.498 0.407 0.333 0.279 1.077 0.910 0.779 0.28 0.720 0.605 0.512 0.431 0.354 0.297 1.144 0.979 0.842 0.29 0.743 0.626 0.530 0.446 0.367 0.310 1.172 1.026 0.885 0.30 0.785 0.663 0.563 0.462 0.382 0.325 1.165 1.041 0.924 0.31 0.807 0.683 0.583 0.458 0.374 0.319 1.150, 1.043 0.924 0.32 0.826 0.704 0.605 0.486 0.392 0.325 1.144 1.041 0.933 0.33 0.828 0.704 0.606 0.504 0.408 0.341 1.099 1.005 0.903 0.34 0.867 0.744 0.642 0.520 0.422 0.354 1.089 1.001 0.927 0.35 0.912 0.780 0.675 0.541 OA39 0.367 1.100 1.013 0.926 0.36 0.936 0.806 0.697 0.564 OA59 0.384 1.064 1.004 0.936 0.37 0.979 0.846 0.736 0.584 0.476 0.408 1.079 1.035 0.985 0.38 1.031 0.892 0.777 0.609 0496 0.418 1.083 1.043 0.998 0.39 1.054 0.921 0.814 0.624 0.503 0.423 1.073 1.038 0.995 0.40 1.107 0.975 0.861 0.664 0.526 0.440 1.043 1.017 0.998 0.41 1.164 1.024 0.901 0.697 0.547 0.457 1.016 1.013 1.007 0.42 1.210 1.070 0.940 0.735 0.574 0.481 1.004 1.002 1.011 0.43 1.183 1.051 0.928 0.735 0.573 0.482 0.957 0.957 0.970 0.44 1.194 1.078 0.955 0.761 0.600 0.514 0.951 0.939 0.947 0.45 1.148 1.054 0.943 0.808 0.658 0.566 0.951 0.883 0.875 0.46 1.137 1.045 0.934 0.847 0.697 0.594 1.007 0.919 0.898 OA7 1.094 1.028 0.932 0.879 0.730 0.623 1.041 0.946 0.899 0.48 1.064 1.002 0.908 0.908 0.767 0.656 1.054 0.964 0.909 0.49 1.042 0.984 0.903 0.905 0.768 0.668 1.072 0.982 0.928 0.50 1.050 0.982 0.882 0.899 0.770 0.677 1.097 1.002 0.948

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 57 of 196 Date: 11/06/02 Period Median Prorile Lower Bound Profile Uppe Bound Profile (sec) 1.2g 1AR 1.6 Ig 1.2 1.4i 1.6 1.2 1.4 1.6 0.51 1.059 0.990 0.888 0.900 0.780 0.692 1.139 1.030 0.963 0.52 1.037 0.969 0.871 0.889 0.773 0.689 1.165 1.045 0.967 0.53 1.017 0.953 0.861 0.886 0.778 0.707 1.210 1.093 1.005 0.54 1.052 0.968 0.865 0.895 0.801 0.735 1.252 1.136 1.049 0.55 1.061 0.967 0.864 0.899 0.806 0.740 1.272 1.155 1.062 0.56 1.079 0.978 0.859 0.900 0.809 0.747 1.316 1.198 1.112 0.57 1.080 0.976 0.844 0.877 0.801 0.758 1.335 1.228 1.133 0.58 1.101 0.999 0.879 0.889 0.819 0.776 1.409 1.296 1.193 0.60 1.109 1.014 0.900 0.892 0.839 0.811 1.476 1.361 1.258 0.62 1.140 1.016 0.872 0.832 0.785 0.763 1.452 1.380 1.297 0.64 1.195 1.043 0.885 0.804 0.749 0.734 1.464 1.414 1.342 0.66 1.290 1.136 0.952 0.796 0.749 0.736 1.474 1.436 1.381 0.68 1.337 1.187 1.003 0.800 0.740 0.720 1.476 1.442 1.398 0.70 1.349 1.180 0.991 0.790 0.726 0.713 1.455 1.428 1.399 0.72 1.375 1.211 1.018 0.806 0.713 0.691 1.485 1.454 1.420 0.74 1.370 1.213 1.035 0.820 0.722 0.675 1.501 1.445 1.410 0.76 1.379 1.238 1.071 0.829 0.733 0.681 1.525 1.470 1.422 0.78 1.392 1.287 1.117 0.859 0.745 0.679 1.515 1.460 1.413 0.80 1.422 1.318 1.149 0.884 0.768 0.698 1.478 1.427 1.382 0.82 1.447 1.345 1.176 0.916 0.796 0.724 1.466 1.424 1.389 0.84 IA36 1.343 1.201 0960 0.834 0.757 1.458 1.405 1.368 0.86 1.443 1.354 1.214 0.970 0.842 0.766 1.475 1.401 1.368 0.88 1.427 1.343 1.207 0.978 0.846 0.771 1.488 1.406 1.354 0.90 1.409 1.329 1.200 0.996 0.864 0.784 1.511 1.424 1.361 0.92 1.390 1.316 1.198 1.018 0.885 0.796 1.529 1.436 1.368 0.94 1.378 1.325 1.244 1.059 0.898 0.807 1.590 1.493 1.421 0.96 1.404 1.348 1.265 1.077 0.911 0.806 1.620 1.523 1.450 0.98 1.416 1.358 1.273 1.091 0.925 0.816 1.639 1.542 1.468 1.00 1.406 1.346 1.262 1.108 0.935 0.823 1.642 1.543 1.468 1.05 1.417 1.358 1.280 1.170 1.016 0.906 1.720 I S86 1.501 1.10 1.411 1.334 1.261 1.190 1.086 0.990 1.877 1.713 1.582 1.15 1.494 1.399 1.322 1.269 1.164 1.070 2.031 1.864 1.729 1.20 1.610 1.469 1.342 1.267 1.178 1.117 2.179 2.026 1.903 1.25 1.687 1.542 1.402 1.228 1.174 1.143 2.181 2.052 1.951 1.30 1.767 1.625 1.482 1.283 1.233 1.209 2.282 2.118 2.011 1.35 1.867 1.708 1.547 1.315 1.256 1.227 2.511 2.353 2.195 1.40 1.900 1.734 1.566 1.314 1.240 1.190 2.611 2.471 2.315 1.45 1.955 1.765 1.580 1.308 1.232 1.181 2.647 2.533 2.419 1.50 2.013 1.820 1.622 1.331 1.249 1.205 2.556 2.483 2.386 1.55 2.089 1.898 1.698 1.366 1.272 1.214 2.467 2.423 2.365 1.60 2.158 1.966 1.762 1.396 1.297 1.230 2.508 2.509 2.469 1.65 2.279 2.041 1.832 1.446 1.346 1.277 2.640 2.667 2.649 1.70 2.314 2.098 1.904 1.499 1.385 1.309 2.635 2.687 2.681 1.75 2.354 2.152 1.952 1.534 1.417 1.339 2.535 2.599 2.608 1.80 2.436 2.229 2.032 1.589 1.466 1.385 2.456 2.513 2.548 1.85 2.471 2.298 2.102 1.632 1.494 1.413 2.402 2.474 2.518 1.90 2.527 2.351 2.181 1.731 1.583 1.487 2.424 2.491 2.533 1.95 2.504 2.392 2.242 1.816 1.661 1.565 2.378 2.449 2.494 2.00 2.450 2.388 2.269 1.845 1.710 1.617 2.205 2.281 2.336 2.05 2.503 2.429 2.301 1.882 1.747 1.657 2.130 2.216 2.288 2.10 2.523 2.444 2.294 1.957 1.782 1.690 2.121 2.200 2.282

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 58 of 196 Date: 11/06/02 Period Median Profile Lower Bound Profile Upper Bound Profile (sec) 1.2 v

1.4 16 1.2g 1 1.4 1.6 1.2 1.4 E 11.6 2.15 2.427 2.387 2.330 2.018 1.855 1.745 2.096 2.169 2.233 2.20 2.403 2.411 2.381 2.085 1.918 1.809 2.055 2.130 2.194 2.25 2.358 2.388 2.360 2.131 1.948 1.833 1.974 2.053 2.120 2.30 2.341 2.372 2.354 2.133 1.971 1.871 1.911 1.995 2.065 2.35 2.333 2.365 2.346 2.170 2.034 1.935 1.870 1.954 2.030 2.40 2.289 2.326 2.323 2.200 2.080 1.983 1.827 1.901 1.974 2.50 2.171 2.229 2.252 2.199 2.092 2.000 1.723 1.794 1.868 2.60 2.197 2.261 2.305 2.319 2.201 2.083 1.741 1.816 1.893 2.70 2.112 2.189 2.248 2.317 2.246 2.155 1.668 1.727 1.793 2.80 1.986 2.066 2.134 2.282 2.235 2.170 1.588 1.646 1.702 2.90 1.804 1.876 1.935 2.229 2.280 2.259 1.525 1.558 1.594 3.00 1.777 1.839 1.887 2.207 2.268 2.262 1.512 1.545 1.579 3.10 1.763 1.828 1.883 2.220 2.309 2.352 1.544 1.573 1.598 3.20 1.762 1.830 1.922 2.240 2.324 2.373 1.542 1.576 1.605 3.30 1.743 1.810 1.884 2.195 2.279 2.327 1.503 1.536 1.567 3.40 1.779 1.829 1.885 2.149 2.245 2.324 1.531 1.571 1.609 3.50 1.814 1.872 1.926 2.156 2.247 2.324 1.533 1.579 1.622 3.60 1.714 1.780 1.844 2.084 2.152 2.227 1.448 I A87 1.525 3.70 1.655 1.708 1.775 2.018 2.092 2.166 1.413 1.455 1.494 3.80 1.602 1.644 1.683 1.903 2.002 2.074 1.361 1.405 1.445 3.90 1.567 1.617 1.665 1.840 1.948 2.030 1.313 1.359 1.401 4.00 1.550 1.612 1.670 1.866 1.958 2.046 1.286 1.320 1.366 4.10 1.545 1.620 1.692 1.922 2.022 2.102 1.324 1.357 1.384 4.20 1.471 1.541 1.601 1.845 1.948 2.027 1.233 1.269 1.298 4.30 1.407 1.469 1.521 1.716 1.821 1.915 1.198 1.222 1.250 4.40 1.343 1.406 1.461 1.647 1.747 1.840 1.167 1.183 1.197 4.50 1.296 1.355 1.412 1.608 1.705 1.792 1.178 1.184 1.191 4.60 1.313 1.352 1.413 1.618 1.688 1.776 1.208 1.223 1.240 4.70 1.383 1.404 1.446 1.633 1.708 1.771 1.259 1.280 1.300 4.80 1.364 1.398 1.450 1.605 1.684 1.748 1.262 1.279 1.297 4.90 1.362 1.371 1.424 1.580 1.627 1.677 1.256 1.274 1.292 5.00 1.359 1.372 IA02 1.571 1.623 1.665 1.237 1.259 1.279 5.10 1.367 1.384 1.403 1.572 1.628 1.674 1.234 1.258 1.280 5.20 1.386 1.418 1.453 1.594 1.646 1.691 1.227 1.253 1.279 5.40 1.371 1.411 1.451 1.611 1.671 1.724 1.193 1.221 1.250 5.60 1.241 1.289 1.337 1.520 1.588 1.650 1.152 1.149 1.151 5.80 1.267 1.281 1.292 1.382 1.423 1.484 1.211 1.219 1.225 6.00 1.291 1.310 1.327 1.404 1.438 1.467 1.210 1.224 1.236 6.20 1.271 1.296 1.322 1.418 1 A54 1.484 1.187 1.201 1.211 6.40 1.283 1.297 1.309 1.385 1.A14 1.439 1.203 1.221 1.236 6.60 1.241 1.263 1.287 1.365 1.395 1.422 1.169 1.177 1.184 6.80 1.199 1.225 1.253 1.339 1.373 1.A04 1.133 1.143 1.152 7.00 1.209 1.224 1.238 1.339 1.377 1.410 1.131 1.142 1.154 7.20 1.202 1.218 1.232 1.324 1.370 1.409 1.125 1.138 1.151 7.40 1.180 1.201 1.221 l.282 1.316 1.346 1.143 1.147 1.149 7.60 1.182 1.200 1.214 1.279 1.310 1.335 1.168 1.173 1.177 7.80 1.182 1.193 1.209 1.282 1.319 1.351 1.147 1.157 1.165 8.00 1.158 1.176 1.193 1.268 1.306 1.339 1.103 1.111 1.118 8.50 1.119 1.118 1.119 1.147 1.185 1.215 1.093 1.094 1.096 9.00 1.163 1.173 1.182 1.210 1.217 1.227 1.117 1.125 9.50 1.189 1.194 1.201 1.228 1.233 1.246 1.133 1.144 1.155 10.00 1.240 1.248 1.258 1.311.

1.321 1.330 1.137 1.154 1.174

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 59 of 196 Date: 11/06/02 Table 7-13. Average and normalized standard error (S.E.) of the median profile amplification factors, input pga 1.2 g.

Average Normalized Period Profle Am lification Factors Amplification S. E.

(sec)

Time History I Time History 2 Tme History 3 Factor

(

0.01 0.742 0.826 0.798 0.788 3.14 0.03 0.740 0.824 0.828 0.797 3.61 0.05 0.525 0.581 0.585 0.563 3.45 0.075 0.425 0.470 0.477 0.457 3.59 0.10 0.408 0.448 0.426 0.427 2.65 0.15 0.402 0.367 0.374 0.381 2.79 0.19 0.441 0.509 0.497 0.482 4.34 0.20 0.534 0.579 0.496 0.536 4.44 0.30 0.852 0.868 0.636 0.785 9.54 0.42 1.297 1.116 1.216 1.210 4.32 0.50 0.892 1.155 1.105 1.050 7.68 0.60 1.021 1.150 ilS5__

1109 394 0.75 1.201 1.447 1.474 1.374 6.32 0.86 1.302 1.485 1.543 1.443 5.05 1.00 1.324 1.449 1.444 1.406 2.90 1.40 1.758 2.010 1.933 1.900 3.93 1.50 1.895 2.126 2.019 2.013 3.32 1.70 2.187 2.407 2.347 2.314 2.84 1.80 2.337 2.505 2.467 2.436 2.10 2.00 2.269 2.512 2.571 2.450 3.77 2.10 2.306 2.614 2.648 2.523 4.32 2.50 2.126 2.269 2.117 2.171 2.28 2.60 2.044 2.238 2.311 2.197 3.63 3.00 1.766 1.765 1.799 1.777 0.64 3.20 1.801 1.651 1.834 1.762 3.21 3.50 1.816 1.670 1.957 1.814 4.57 4.00 1.580 1.546 1.525 1.550 1.03 5.00 1.261 1.405 1.411 1.359 3.60 7.00 1.142 1.136 1.349 1.209 5.77 10.00 1.180 1 1.325 1.215 1.240 3.52

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 60 of 196 Date: 11/06/02 Table 7-14. Average and normalized standard error (S. E.) of the median profile amplification factors, input pga 1.4 g.

Average Normalized Period Profile Amplification Factors Amplification S. E.

(see)

Time History I Time History 2 Time History 3 Factor l/)

0.01 0.628 0.754 0.697 0.693 5.24 0.03 0.626 0.752 0.724 0.701 5.44 0.05 0.444 0530 0.511 0.495 5.30 0.075 0.359 0.429 0.417 0.402 5.43 0.10 0.340 0.404 0.373 0.372 5.01 0.15 0.332 0.340 0.327 0.333 1.10 0.19 0.361 0.430 0.416 0.403 5.22 0.20 0.427 OA89 0.418 0.445 5.04 0.30 0.703 0.759 0.527 0.663 10.53 0.42 1.173 0.985 1.051 1.070 5.16 0.50 0.856 1.130 0.961 0.982 8.12 0.60 0.933 1.109 1.000 1.014 5.06 0.75 1.075 1.381 1.221 1.225 7.21 0.86 1.211 1.454 1.397 1.354 5.41 1.00 1.260 IAI 1 1.368 1.346 3.35 1.40 1.619 1.799 1.784 1.734 3.34 1.50 1.697 1.902 1.862 1.820 3.45 1.70 1.994 2.254 2.045 2.098 3.80 1.80 2.128 2.370 2.188 2.229 3.27 2.00 2.193 2.517 2.453 2.388 4.16 2.10 2.235 2.585 2.511 2.444 4.36 2.50 2.103 2.346 2.238 2.229 3.15 2.60 2.029 2.317 2.437 2.261 5.36 3.00 1.748 1.834 1.936 1.839 2.94 3.20 1.792 1.720 1.978 1.830 4.19 3.50 1.822 1.729 2.066 1.872 5.37 4.00 1.629 1.596 1.609 1.612 0.59 5.00 1.290 1.443 1.384 1.372 3.24 7.00 1.161 1.154 1.358 1.224 5.47 10.00 1.189 1.340 1.215 1.248 3.74

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 61 of 196 Date: 11/06/02 Table 7-15. Average and normalized standard error (S. E.) of the median profile amplification factors, input pga 1.6 g.

Average Normalized Period Profl Ampliflcation Factors Amplification S. E.

(sec)

Time History 1 Time History 2 Time History 3 Factor

(%/)

0.01 0.545 0.680 0.600 0.608 6.45 0.03 0.543 0.678 0.623 0.615 6.38 0.05 0.384 0.478 0.440 0.434 6.26 0.075 0.306 0.386 0.356 0.352 6.71 0.10 0.290 0.362 0.321 0.324 6.39 0.15 0.280 0.311 0.285 0.292 3.25 0.19 0.305 0.357 0.354 0.339 4.94 0.20 0.357 0.405 0.366 0.376 3.90 0.30 0.593 0.651 0.445 0.563 10.91 0.42 1.040 0.856 0.925 0.940 5.71 0.50 0.782 1.049 0.815 0.882 9.52 0.60 0.804 1.044 0.853 0.900 8.14 0.75 0.945 1.236 0.978 1.053 8.75 0.86 1.088 1.384 1.170 1.214 7.26 1.00 1.178 1.349-1.260 1.262 3.92 1.40 1.499 1.580 1.618 1.566 2.25 1.50 1.518 1.658 1.691 1.622 3.27 1.70 1.808 2.034 1.872 1.904 3.53 1.80 1.940 2.144 2.012 2.032 2.94 2.00 2.102 2.441 2.265 2.269 4.31 2.10 2.149 2.456 2.278 2.294 3.87 2.50 2.061 2.413 2.283 2.252 4.57 2.60 1.994 2.391 2.531 2.305 6.97 3.00 1.727 1.906 2.029 1.887 4.64 3.20 1.874 1.800 2.094 1.922 4.59 3.50 1.825 1.798 2.154 1.926 5.95 4.00 1.670 1.655 1.684 1.670 0.49 5.00 1.322 1.485 1.398 1.402 3.36 7.00 1.181 1.171 1.363 1.238 5.05 10.00 1.201 1.360 1.213 1.258 4.06

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 62 of 196 Date: 11/06/02 Table 7-16. Average and normalized standard error (S. E.) of the lower bound profile amplification factors, input pga 1.2 g.

Avcrage Normalized Period Profile Amplification Factors Amplification S. E.

(sec Time History 1 Time History 2 Time History 3 Factor

(%)

0.01 0.402 0.511 0.496 0.470 7.23 0.03 0.400 0.509 0.5 15 0.475 7.86 0.05 0.283 0.359 0.364 0.335 7.84 0.075 0.227 0.291 0.297 0.272 8.26 0.10 0.209 0.270 0.266 0.248 7.98 0.15 0.226 0.235 0.237 0.232 1.46 0.19 0.232 0.260 0.287 0.260 6.11 0.20 0.283 0.293 0.286 0.287 0.99 0.30 0.460 0.491 0.437 0.462 3.35 OA2 0.809 0.670 0.725 0.735 5.46 0.50 0.827 0.967 0.903 0.899 4.49 0.60 0.797 0.974 0.904 0.892 5.77 0.75 0.823 0.840 0.811 0.825 1.01 0.86 0.874 1.098 0.939 0.970 6.84 1.00 1.060 1.166 1.097 1.108 2.82 1.40 1.288 1.261 1.394 1.314 3.09 1.50 1.255 1.302 1.437 1.331 4.08 1.70 1.534 1.386 1.576 1.499 3.84 1.80 1.709 1.392 1.666 1.589 6.25 2.00 1.861 1.824 1.851 1.845 0.59 2.10 1.913 2.021 1.938 1.957 1.66 2.50 1.919 2A13 2.264 2.199 6.65 2.60 1.881 2A24 2.653 2.319 9.87 3.00 2.054 2.282 2.287 2.207 3.48 3.20 2.307 2.114 2.297 2.240 2.80 3.50 1.959 2.087 2.422 2.156 6.40 4.00 1.801 1.873 1.923 1.866 1.90 5.00 1.479 1.602 1.634 1.571 3.01 7.00 1.265 1.340 1.412 1.339 3.16 10.00 1.264 IA21 1.248 1.311 4.22

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number. 63 of 196 Date: 11/06/02 Table 7-17. Average and normalized standard error (S. E.) of the lower bound profile amplification factors, input pga 1.4g.

Average Normalized Period Profile Amplification Factors Amplification S. E.

(see)

Time History 1 Time History 2 Tme History 3 Factor

(%/ )

0.01 0.352 0.435 0.442 0.410 7.03 0.03 0.350 0.433 0.459 0.414 7.93 0.05 0.247 0.305 0.324 0.292 7.95 0.075 0.198 0.246 0.265 0.236 8.48 0.10 0.180 0.227 0.238 0.215 8.29 0.15 0.173 0.202 0.212 0.196 6.01 0.19 0.180 0.221 0.246 0.216 8.94 0.20 0.212 0.233 0.233 0.226 3.15 0.30 0.368 0,386 0.391 0.382 1.81 0.42 0.608 0.527 0.586 0.574 4.21 0.50 0.706 0.825 0.780 0.770 4.51 0.60 0.791 0.874 0.852 0.839 2.94 0.75 0.734 0.726 0.722 0.727 0.52 0.86 0.774 0.934 0.818 0.842 5.70 1.00 0.915 0.993 0.897 0.935 3.13 1.40 1.208 1.228 1.282 1.240 1.78 1.50 1.171 1.252 1.325 1.249 3.58 1.70 1.428 1.265 1.463 1.385 4.42 1.80 1.593 1.258 1.547

.1.466 7.15 2.00 1.739 1.646 1.743 1.710 1.86 2.10 1.794 1.774 1.779 1.782 0.33 2.50 1.817 2.282 2.177 2.092 6.72 2.60 1.793 2.301 2.509 2.201 9.66 3.00 2.149 2.349 2.306 2.268 2.67 3.20 2.468 2.223 2.282 2.324 3.18 3.50 2.060 2.195 2.486 2.247 5.59 4.00 1.941 1.929 2.004 1.958 1.18 5.00 1.552 1.623 1.694 1.623 2.52 7.00 1.309 1.392 1

1.432 1.377 2.63 10.00 1.269 1.432 1.262 1.321 4.21

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 64 of 196 Date: 11/06/02 Table 7-18. Average and normalized standard error (S. E.) of the lower bound profile amplification factors, input pga 1.6g.

Average Normalized Period Profile Amplification Factors Amplification S. E.

(sec)

Time History 1 Time Historg 2 Time History 3 Factor

( )

0.01 0.336 0.402 0.412 0.383 6.21 0.03 0.334 0.400 0.428 0.387 7.18 0.05 0235 0.281 0.302 0.273 7.21 0.075 0.179 0.223 0.239 0.221 8.40 0.10 0.171 0.209 0.222 0.201 7.53 0.15 0.160 0.187 0.199 0.182 6.29 0.19 0.162 0.199 0.221 0.194 8.80 0.20 0.166 0.200 0.213 0.193 7.32 0.30 0.306 0.324 0.344 0.325 3.40 0.42 0.506 0.442 0.494 0.481 4.09 0.50 0.619 0.732 0.680 0.678 4.83 0.60 0.805 0.804 0.825 0.811 0.84 0.75 0.705 0.655 0.672 0.677 2.14 0.86 0.728 0.824 0.744 0.766 3.86 1.00 0.810 0.887 0.771 0.823 4.16 1.40 1.159 1.205 1.207 1.190 1.31 1.50 1.110 1.251 1.252 1.205 3.90 1.70 1.342 1.200 1.386 1.309 4.28 1.80 1.497 1.190 1.467 1.385 7.05 2.00 1.644 1.534 1.674 1.617 2.63 2.10 1,700 1.680 1.691 1.690 0.34 2.50 1.730 2.167 2.103 2.000 6.81 2.60 1.715 2.192 2.343 2.083 9.09 3.00 2.172 2.351 2.265 2.262 2.29 3.20 2.564 2.272 2.283 2.373 4.04 3.50 2.125 2.283 2.563 2.324 5.52 4.00 2.053 2.013 2.073 2.046 0.86 5.00 1.611 1.641 1.743 1.665 2.40 7.00 1.349 1.427 1.454 1.410 2.23 10.00 1.264-1.444 1.281 1.330 4.31

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 65 of 196 Date: 11/06/02 Table 7-19. Average and normalized standard error (S. E.) of the upper bound profile amplification factors, input pga 1.2 g.

Average Normalized Period Profile Amplification Factors Amplification S. E.

(sec)

Time History 1 Time History 2 Time History 3 Factor (0/ )

0.01 0.928 0.786 0.950 0.888 5.82 0.03 0.928 0.785 0.990 0.901 6.75 0.05 0.664 0.555 0.702 0.641 6.90 0.075 0.560 0.446 0.581 0.529 7.95 0.10 0.554 0.510 0.558 0.541 2.85 0.15 0.671 0.609 0.512 0.597 7.72 0.19 0.797 0.811 0.650 0.753 6.85 0.20 0.863 0.903 0.669 0.812 8.93 0.30 1.266 1.073 1.155 1.165 4.79 0.42 1.016 0.970 1.024 1.004 1.67 0.50 1.102 1.094 1.095 1.097 0.21 0.60 1.597 1.360 1.473 1.476 4.63 0.75 1.491 1.449 1.599 1.513 2.95 0.86 1.540 1.487 1.398 1.475 2.81 1.00 1.650 1.574 1.701 1.642 2.25 1.40 2.706 2.586 2.541 2.611 1.89 1.50 2.656 2.640 2.372 2.556 3.59 1.70 2.635 2.607 2.663 2.635 0.61 1.80 2.514 2.283 2.572 2.456 3.59 2.00 2.177 2.021 2.416 2.205 5.21 2.10 2.115 2.023 2.224 2.121 2.74 2.50 1.756 1.807 1.607 1.723 3.48 2.60 1.656 1.773 1.794 1.741 2.47 3.00 1.647 1.430 1.458 1.512 4.50 3.20 1.653 1.417 1.556 1.542 4.45 3.50 1.615 1.355 1.629 1.533 5.82 4.00 1.324 1.317 1.218 1.286 2.68 5.00 1.172 1.200 1.340 1.237 4.18 7.00 1.080 1.066 1.245 1.131 5.09 10.00 1.038 1.230 1.143 1.137 4.88

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 66 of 196 Date: 11/06/02 Table 7-20. Average and normalized standard error (S. E.) of the upper bound profile amplification factors, input pga 1.4g.

Average Normalized Period ProfUle Amplification Factors Amplification S. L (sec)

Time History 1 Time History 2 Time Histor 3 Factor (9

0.01 0.876 0.782 0.879 0.846 3.76 0.03 0.874 0.779 0.915 0.856 4.69 0.05 0.621 0.548 0.647 0.605 4.92 0.075 0.506 0.445 0.532 0.494 5.20 0.10 0.502 0.448 0.497 0.483 3.55 0.15 0.562 0.484 0.446 0.497 6.83 0.19 0.666 0.703 0.578 0.649 5.69 0.20 0.733 0.789 0.593 0.705 8.26 0.30 1.142 0.998 0.983 1.041 4.85 0.42 1.014 0.963 1.029 1.002 1.98 0.50 0.972 1.009 1.025 1.002 1.58 0.60 1.472 1.230 1.382 1.361 5.9 0.75 1.401 1.395 1.576 1.457 4.07 0.86 1.452 1.409 1.343 1.401 2.26 1.00 1.525 1.493 1.612 1-543 2.31 1.40 2.564 2.488 2.362 2.471 2.39 1.50 2.585 2.565 2.300 2.483 3.70 1.70 2.724 2.640 2.696 2.687 0.92 1.80 2.585 2.332 2.621 2.513 3.61 2.00 2.252 2.132 2.459

_2.281 4.18 2.10 2.182 2.109 2.310 2.200 2.67 2.50 1.851 1.876 1.656 1.794 3.86 2.60 1.741 1.843 1.864 1.816 2.09 3.00 1.679 1 A78 1.477 1.545 4.36 3.20 1.691 1.460 1.576 1.576 4.23 3.50 1.662 1.413 1.662 1.579 5.26 4.00 1.351 1.362 1.247

_--.320 __

2.78 5.00 1.181 1.239 1.356 1.259 4.10 7.00 1.088 1.075 1.261 1.142 5.24 10.00 1.056 1.248 1.159 1.154 4.81

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 67 of 196 Date: 11/06/02 Table 7-21. Average and normalized standard error (S. E.) of the upper bound profile amplification factors, input pga 1.6g Average Normalized Period Profile Ampliflcatlon Factors Amplification S. E.

(see)

Time History I Time History 2 Time History 3 Factor (n.)

0.01 0.815 0.782 0.842 0.813 2.12 0.03 0.813 0.780 0.875 0.822 3.38 0.05 0.577 0.549 0.618 0.581 3.43 0.075 0.469 0.444 0.507 0.474 3.86 0.10 0.456 0.416 0.461 0.444 3.23 0.15 0.487 0.408 0.409 0.435 6.03 0.19 0.536 0.591 0.544 0.557 3.11 0.20 0.600 0.672 0.534 0.602 6.58 0.30 1.021 0.911 0.840 0.924 5.71 0.42 1.023 0.955 1.055 1.011 2.91 0.50 0.879 0.958 1.007 0.948 3.92 0.60 1.349 1.121 1.304 1.25S 5.56 0.75 1.350 1.343 1.542 1.412 4.62 0.86 1.377 1.362 1.363 1.368 0.35 1.00 1.432 1.432 1.539 1.468 2.44 1.40 2.390 2.375 2.179 2.315 2.94 1.50 2.465 2.470 2.221 2.386 3.44 1.70 2.719 2.633 2.690 2.681 0.94 1.80 2.616 2.386 2.642 2.548 3.20 2.00 2.288 2.228 2A91 2.336 3.41 2.10 2.227 2.227 2.392 2.282 2.40 2.50 1.927 1.947 1.730 1.868 3.70 2.60 1.825 1.915 1.938 1.893 1.81 3.00 1.702 1.531 1.505 1.579 3.90 3.20 1.718 1.500 1.599 1.605 3.93 3.50 1.698 1.68 1.701 1.622 4.76 4.00 1.400 I.40 1

1.296 1.366 2.54

_5.00 1.190 1.275 1.371 1.279 I

4.10 7.00 1.098 1.086 1.278 1.154 5.38 10.00 1.083 1.264 1.173 1.174 4.45

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 68 of 196 Date: 1 1/06/02 Figure 7-14. Average amplification factors, 1.2 g input pga

~Median Lower Bound

-'p 2.5 Upper Bound A

Selected Periods Selected Periods 2

Selected Periods

~

s.

.2

0.

1

.2 1.5-

-phl.

E 0.5

-I fill....

0.01 0.1 1

10 Period (Sec)

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number 69 of 196 Date: 11/06/02 Figure 7-15. Average amplification factors, 1.4 g input pga 3

-I-I-I-Median Lower Bound 2.5 Upper Bound Selected Periods Selected Periods 2

Selected Periods

/

C a

L1 C0 011 E

0.01 0.1 1

10 I

Period (Sec)

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 70 of 196 Date: 11/06/02 Figure 7-16. Average amplification factors, 1.6 g input pga 2.5 2.5 -

_ ~Median ____/-i _

-Lower Bound Upper Bound 2

Selected Periods

_7 Co-Selected Periods 1

M~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

C Selected Periods I I I

E 0 1_

_ _._ X l 5'U j

\\33\\_

c:

E

~~~~~~V

<~~~~~~~~~~~~~

0.5 0.01 0.1 1

10 Period (Sec)

Calc Number. GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 71 of 196 Date: 11/06/02 7.2 Empirical Constraint on Spectral Shape An empirical constraint was developed to account for the potential over-damping of high frequency spectral content by SHAKE.

7.2.1 Select Time histories Based on Assumption 3.2, 14 time histories ( 2 horizontal components from 7 stations) from soil sites that recorded the 1994 Northridge earthquake with peak ground accelerations greater than 0.4g and having shear wave velocity profiles (http://geoinfo.usc.edu/rosrine/) similar to the HBIP shear wave velocity range were used for empirical constraints on the high frequency spectral shape (Idriss, 2002). The selected time histories are listed in Table 7-22.

Table 7-22. Ground motion recordings used to develop average horizontal rock shape.

Station Name Symbol Rupture Orientation PGA PGV PGD Distance (deg)

(Q)

(cm/s)

(cm)

Rinaldi Receiving Station RRS228 27.6 228 0.838 166.1 28.78 RRS318 318 0.472 73.0 19.76 Sylmar Converter Station East SCE018 6.1 018 0.828 117.5 34.22 SCE288 288 0.493 74.6 28.69 Sylmar Converter Station SCS052 6.2 052 0.612 117.4 53.47 SCS142 142 0.897 102.8 46.99 Sepulveda VA SPV270 8.9 270 0.753 84.8 18.68 SCS360 360 0.939 76.6 14.95 Sylmar, Olive View Medical SYLO90 6.4 090 0.604 78.2 16.05 SYL360 360 0.843 129.6 32.68 Newhall - Fire Station NWHO90 7.1 090 0.583 75.5 17.57 NWH360 360 0.590 97.2 38.05 Jensen Filter Plant JEN022 6.2 022 0.424 106.2 43.06 JEN292 292 0.593 99.3 24.00

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 72 of 196 Date: 11/06/02 7.2.2 Compute Response Spectra Response spectral accelerations at sixteen spectral periods and 5% damping for each of the fourteen time histories were computed using the program SPCTLR.EXE. The results are shown in pseudo-acceleration in Table 7-32 below.

Table 7-23. 5% damped response spectral accelerations for fourteen ground motion recordings in Table 7-22.

Period ___

Pseo Spectral lceenIons RRS RRS SCE SCE SCS SCS SPV SPV SYL SYL JEN JEN NWH NWH (sec) 228 318 018 288 052 142 270 360 090 360 022 292 090 360 0.01 0.838 0.473 0.828 0.493 0.615 0.900 0.756 944 0.609 0.853 0.426 0.593 0.585 0.597 0.02 0.840 0.475 0.831 0.497 0.621 0.909 0.761 0.951 0.613 0.862 0.427 0.595 0.586 0.604 0.03 0.844 0.478 0.839 0.504 0.636 0.933 0.757 0.974 0.604 0.908 0.425 0.596 0.581 0.600 0.05 0.904 0.795 0.895 0.516 0.655 0.998 0.768 0.947 0.605 0.956 0.431 0.613 0.614 0.618 0.08 0.946 0.912 1.087 0.646 0.851 0.983 0.800 0.950 0.655 1.090 0.456 0.629 0.703 0.746 0.10 1.0351 0.918 1.151 0.751 0.776 1.108 0.872 1.191 1.014 1.255 0.453 0.649 0.971 0.846 0.15 1.195 1.229 1.358 1.519 0.711 1.263 1.003 1.461 0.821 1.304 0.506 0.878 1.404 0.922 0.20 1.483 1.288 1.509 1.372 1.070 1.374 1.341 2.204 0.920 1.225 0.558 0.945 1.227 1.396 0.30 1.754 1.754 1.631 0.794 1.007 1.304 1.120 2.784 1.062 2.616 0.904 1.128 2.423 1.956 0.50 1.770 1.014 1.282 0.696 1.125 1.468 1.484 1.651 1.341 1.991 0.648 1.467 1.204 1.640 0.75 2.039 0.911 1.418 0.920 1.765 1.553 1.649 1.425 0.855 1.204 1.117 1.575 0.710 1.881 1.00 1.825 0.812 0.768 0.978 1.356 1.396 1.128 0.633 0.616 0.867 1.102 1.770 0.739 1.172 t.50 1.001 0.518 0.601 0.566 0.649 1.271 0.432 0.256 0.443 0.850 0.644 0.960 0.520 o.772 2.00 0.571 0.477 0.418 0.512 0.630 0.703 0.271 0.203 0450 0.616 0.498 0.763 0.260 0.439 3.00 0.261 0.245 0.356 0.260 0.567 0.184 0.083 0.248 0.263 0.343 0.509 0.250 0.156 0.187 4.00 0.149 0.083 0.174 0.100 0.237 0.100 0.049 0.096 0.092 0.126 0257 0.096 0.097 0.153

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 73 of 196 Date: 11/06/02 7.2.3 Compute Average Spectral Shape The spectral shapes for each of the fourteen records were obtained by normalizing the response spectral values to their respective peak ground accelerations. The results of the normalization are presented in Table 7-24.

Table 7-24. Spectral shapes for the fourteen ground motion recordings in Table 7-22.

Period Sectral Shape RRS RRS SCE SCE SCS SCS SPV SPV SYL SYL JEN JEN NWH NWH (sec) 228 318 018 288 052 142 270 360 090 360 022 292 090 360 0.010 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 0.020 1.003 1.005 1.004 1.007 1.010 1.010 1.007 1.007 1.006 1.011 1.003 1.003 1.002 1.011 0.030 1.008 1.011 1.013 1.023 1.034 1.036 1.002 1.032 0.991 1.065 1.000 1.004 0.994 1.005 0.050 1.079 1.682 1.080 1.047 1.065 1.109 1.018 1.003 0.992 1.121 1.012 1.032 1.049 1.038 0.075 1.130 1.929 1.312 1.310 1.383 1.091 1.058 1.008 1.074 1.278 1.072 1.060 1.202 1.250 0.100 1.238 1.942 1.389 1.523 1.261 1.230 1.154 1.261 1.664 1.471 1.06 1.094 1.661 1.417 0.150 1.426 2.601 1.639 3.079 1.155 1.403 1.327 1.547 1.347 1.529 1.189 1.479 2.400 1.543 0.200 1.770 2.726 1.822 2.782 1.740 1.527 1.774 2.334 1.510 1.436 1.311 1.592 2.098 2.338 0.300 2.094 3.712 1.969 1.611 1.637 1.449 1.483 2.949 1.742 3.067 2.12S 1.900 4.143 3.275 0.500 2.113 2.146 1.547 1.412 1.829 1.530 1.964 1.749 2.200 2.335 1.524 2.472 2.058 2.747 0.750 2.435 1.927 1.711 1.865 2.889 1.725 2.182 1.509 1.402 1.412 2.625 2.654 1.214 3.150 1.000 2.179 1.718 0.927 1.983 2.204 1.551 1.A93 0.670 1.011 1.018 2.590 2.983 1.263 1.963 1.500 1.195 1.096 0.726 1.148 1.055 1.411 0.572 0.271 0.726 0.998 1.512 1.617 0.888 1.293 2.000 0.682 1.010 0.50S 1.038 1.024 0.781 0.359 0.215 0.738 0.723 1.170 1.286 0445 0.734 3.000 0.312 0.518 0.430 0.527 0.921 0.204 0.110 0.263 0.431 0.402 1.198 0.421 0.268 0.313 4.000 0.177 0.176 0.210 0.203 0.384 0.111 0.065 0.101 0.151 0.148

.604 0.162 0.18 0.258 The final average horizontal spectral shape is determined by taking the linear average of the fourteen spectral shapes in Table 7-24. This final spectral shape is presented in Table 7-25 below.

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 74 of 196 Date: 11/06/02 Table 7-25 Average horizontal rock spectral shape based on 14 Northridge strong motion recordings.

Period Average (se Spectral Shape 0.010 1.0000 0.020 1.0063 0.030 1.0155 0.050 1.0945 0.075 1.2255 0.100 1.3835 0.150 1.6904 0.200 1.9114 0.300 2.3682 0.500 1.9805 0.750 2.0486 1.000 1.6823 1.500 1.0362 2.000 0.7649 3.000 0.4510 4.000 0.2081

8. RESULTS The average site-specific soil amplification factors for input rock pga levels of 1.4 g and 1.6 g are listed in Table 8-1. These amplification factors are applicable to rock spectra developed for "generic" soft-rock sites, consistent with the definition of rock used in the developing the empirical attenuation relations used in California.

The empirical spectral shape for large ground motions (PGA>0.6g) for soil sites with shear-wave velocity profiles similar to the profile at HBIP is listed in Table 8-2.

Calc Number. GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 75 of 196 Date: 11/06/02 Table 8-1. Average amplification factors Period Median Lower Bound Upper Bound (sec) 1.4 g 1.6 g-1.4 g 1.6 g 1.4 g 1.6 g 0.010 0.693 0.608 0.410 0.383 0.846 0.813 0.030 0.701 0.615 0.414 0.387 0.856 0.822 0.050 0.495 0.434 0.292 0.273 0.605 0.581 0.075 0.402 0.352 0.236 0.221 0.494 0.473 0.100 0.372 0.324 0.215 0.201 0.483 0.444 0.150 0.333 0.292 0.196 0.182 0.497 0.435 0.200 0.445 0.376 0.226 0.193 0.705 0.602 0.300 0.663 0.563 0.382 0.325 1.041 0.924 0.420 1.070 0.940 0.574 0.481 1.002 1.011 0.500 0.982 0.882 0.770 0.677 1.002 0.948 0.600 1.014 0.900 0.839 0.811 1.361 1.258 0.640 1.043 0.885 0.749 0.734 1.414 1.342 0.750 1.225 1.053 0.727 0.678 1.457 1.416 0.860 1.354 1.214 0.842 0.766 1.401 1.368 1.000 1.346 1.262 0.935 0.823 1.543 1.468 1.200 1.469 1.342 1.178 1.117 2.026 1.903 1.450 1.765 1.580 1.232 1.181 2.533 2.419 1.700 2.098 1.904 1.385 1.309 2.687 2.681 2.200 2.411 2.381 1.91

_ 1.809 2.130 2.194 2.600 2.261 2.305 2.201 2.083 1.816 1.893 3.200 1.830 1.922 2.324 2.373 1.576 1.605 3.500 1.872 1.926 2.247 2.324 1.579 1.622 4.100 1.620 1.692 2.022 2.102 1.357 1.384 4.300 1.469 1.521 1.821 1.915 1.222 1.250 SA00 1.411 1.451 1.671 1.724 1.221 1.250 6.200 1.296 1.322 1.454

_1.484 1.201 1.211 7.800 1.193 1.209 1.319 1.3S1 1.157 1.165 10.000 1.248 1.258 1.321 1.330 1.154 1.174 Note: Values for amplification factors for 0.075 and 0.75 seconds are from Tables 7-22 through 30. All other periods are from Tables 7-18 through 7-21.

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 76 of 196 Date: 11/06/02 Table 8-2. Average Horizontal Rock Spectral Shape Based on Northridge Strong Motion Recordings.

Period (sec)

Average Spectral Shape (Salpga) 0.010 1.000 0.020 1.000 0.030 1.016 0.050 1.095 0.075 1.225 0.100 1.384 0.150 1.690 0.200 1.911 0.300 2.368 0.500 1.980 0.750 2.049 1.000 1.682 1.500 1.036 2.000 0.765 3.000 0.451 4.000 0.208

Calc Number GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 77 of 196 Date: 1 1/06/02

9. CONCLUSIONS The amplification factors (Table 8-1) represent the site amplification of earthquake ground motion at the HBIP site at input pga motion levels of 1.4 g and 1.6g. The amplified surface soil spectrum should be check against Table 8-2 to ensure that the final spectrum has sufficient spectral contents, especially in the high frequency range.

Limitations:

1. The calculations were performed for a M7.8 earthquake. They may be applied to earthquakes with magnitudes from 7.5 to 7.8, with some conservatism at long periods for M<7.8.
2. Due to use of three time histories in the site response analyses, the uncertainty in the average amplification factors is in the range of 0.5% to 10%. Therefore, the median value of the amplification factors are accurate to 10% due to the limited number of time histories used.
10. REFERENCES Abrahamson, N. A., and W. J. Silva (1997) "Empirical Response Spectral Attenuation Relations for Shallow Crustal Earthquakes", Seismological Research Letters, Vol. 68, No. 1, pp.94-127.

ASCE4, (1986) Seismic Analysis of Safety-Related Nuclear Structures and Commentary on Standard for Seismic Analysis of Safety Related Nuclear Structures, published by American Society of Civil Engineers, N.Y., N.Y., September 1986.

Bevington, P. R. (1969). Data Reduction and Error Analysis for the Physical Sciences, McGraw-Hill.

GEO.HBIP.02.04, rev 0, Development of Response Spectra for the HBEP ISFSL prepared by PG&E Geosciences Department, November 2002.

GEO.DCPP.01.32, Verification of Computer Program SPCTLR.EXE, prepared by PG&E Geosciences Department for DCPP, ISFSI, August, 2002 Idriss I.M. and Sun, J.I. (1991) User's Manual for SHAKE91, A Computer Program for Conducting Equivalent Linear Seismic Response Analyses of Horizontally Layered Soil Deposits, published by Center for Geotechnical Modeling, Department of Civil and Environmental Engineering, University of California, Davis, November, 1992.

Idriss, I.M., (2002) Humboldt Nuclear Power Plant ISFSI Project, Letter to Norm Abrahamson, PG&E Geosciences Department, dated July 25, 2002.

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 78 of 196 Date: 11/06/02 Schnabel, P. B., Lysmer, J., and H. B. Seed (1972) "SHAKE: A Computer Program for Earthquake Response Analysis of Horizontally Layered Sites", Report No. UCB/EERC-72/12, Earthquake Engineering Research Center, University of California, Berkeley, December.

Seed, H.B. and Idriss, I.M. (1970) Soil Moduli and Damping Factors for Dynamic Response Analyses, Report No. EERC 70-10, Earthquake Engineering Research Center, University of California, Berkeley, December, 1970, 40 pp.

White, R.K., (2002) Review and Acceptance of ICEC SHAKE verification documentation, Letter to Chris Hartz, UFSP, DCPPm Amy 30, 2002.

White, R. K. (2002) Ground Response Analysis for Humbolt Bay ISFSI Project, Letter to Ann Becker with attachments, May 31, 2002.

Calc Number: GEO.HBIP.02.06 Rev Nunber: 0 Sheet Number: 79 of 196 Date: 11/06/02

11. ENCLOSURES AND ATTACHMENTS Enclosed CD-ROM contains the input and output files for ground response analysis using SHAKE96. Detailed description of the CD contents are listed below. A copy of the CD is filed under calculation package GEO.HBIP.02.06 available with PG&E Geosciences Department.

Appendix A contains the spectral shapes of the various ground response analysis Appendix B contains the printout of the 3 acceleration time histories used in the analysis Appendix C contains the key input of the ground response analysis Appendix D contains the key output of the ground response analysis README.TXT - DESCRIPTION OF CONTENTS ON CD The files and directories on this cd were used for the HBPP SHAKE analyses perormed in June, 2002 for calculation package GEO.HBIP.02.06 Rev. 0.

An files other than those Identified below are ASCII files (text files) that can be viewed by any text editor such as MS NotePad or WordPad programs or be Imported into any word processor such as MS WORD for viewing.

The four binary files under subdirectory SHAKE98 and one binary me under Northridge that cannot be read as text files are:

SHAKE96.EXE Executable file for SHAKE used In the analyses SHAKE96S.EXE Verified SHAKE program used to verify SHAKE96.

RUN386.EXE Lahey DOS Extender File needed for SHAKE96S.EXE F77L3.EER Lahey Error Messages File needed for SHAKE96S.EXE SPCTLR.EXE Executable file for SPCTLR DESCRIPTION OF FILE STRUCTURE ON CD The Input time histories are In directory 'inpuLth'; the program Is the executable SHAKE96.exe.

The remaining directories contain all Input and output files.

The directory naming scheme Includes the profile designation.

The profile analyzed is called profie m1'. Profile m2 Isthe lower bound and m3 is the upper bound on m1I. The earthquake used appears next hI the directory name: eqs 7 through 9 correspond to time histories sent by Norm Abrahamson (directory inpuLth')

according to:

Eq 7= M7.8 Set I Eq 8 = M7.8 Set 2 Eq 9 M7.8 Set 3.

In the 'Input' subdirectories under each mxyjruns' are the SHAKE input files.

The naming convention includes the profile designation and the Input pga used, with the letter p' standing in for a decimal. For example, file m2_1pOg.lnp In directory m28j'uns' models the lower bound profile, M7.8 Set 2 input time history, with pga scaled to 1.0g.

The output file suffixes correspond to:

  • .out - SHAKE output file

=.at 5 ACC time history file (at ground surface)

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 80 of 196 Date: 11/06/02

.rsp = response spectrum of surface motion SHAKE96 Test Run directory contains the executable file of SHAKE96 used for this project Testinp is the test run Input file. Test.out is the test run putput file. Dam.acc is the nput ACC time history used by Testinp. Testout is checked against the SHAKE96S.out under the subdirectoy Verified SHAKE96S' which was run the verified SHAKE96S using the same Test.inp and the Diam.acc.

Northridge subdirectoy contains the 14 records used to establish the high frequecy constraints on the surface response spectrum.

.at2 = recorded time histories

  • .050 = 5% damped spectrum computed by SPCTLR

.inp = input files for SPCTLR UST OF FILES Directory of CD FOR GEO.HBIP.02.06 REV.0 10/29/2002 01:52p 1 292002 01 :52p 10/29/2002 01:50p 10/29/2002 01:17p 10/29/2002 01:16p 029/2002 01:16p 10/22002 01:15p 10/29/2002 01:14p 10/29/2002 01:14p 10/29/2002 01:14p 10/29/2002 01:13p 10/29/2002 01:13p 06/27/2002 08:17a 10/2912002 01 -48p 2 Fle(s)

<DIR>

<DIR>

<DIR>

Input-th THREE INPUT TIME HISTORIES USED IN THE ANALYSES

<DIR>

ml7_runs ANALYSIS FOR THE MEDIAN PROFILE WITH EQ SET 1

<DIR>

mlnms ANALYSIS FOR THE MEDIAN PROFILE WITH EQ SET 2

<DIR>

mlg_runs ANALYSIS FOR THE MEDIAN PROFILE WITH EQ SET 3

<DIR>

m27_njns ANALYSIS FOR THE LOWER BOUND PROFILE WITH EQ SET 1

<DIR m28_runs ANALYSIS FOR THE LOWER BOUND PROFILE WITH EQ SET 2

<DIR>

m29-runs ANALYSIS FOR THE LOWER BOUND PROFILE WITH EQ SET 3

<DIR>

m37runs ANALYSIS FOR THE UPPER BOUND PROFILE WITH EQ SET 1

<DIR>

m38&runs ANALYSIS FOR THE LOWER BOUND PROFILE WITH EQ SET 2

<DIR>

m39nms ANALYSIS FOR THE LOWER BOUND PROFILE WITH EQ SET 3 1,446 readme.txt

<DIR>

SHAKE96 Test Run 1,446 bytes Directory of CD FOR GEO.HBIP.02.06 REV.Olnputh THREE INPUT TIME HISTORIES USED IN THE ANALYSES 10/29/2002 01 :50p 1029/2002 01:60p 05(29/2002 03:17a 05/29/2002 03:17a 05(29(2002 03:17a 3 File(s)

<DIR>

<DIR>

67.422 m78setl.acc GROUND MOTION SET 1 123,100 m78set2.acc GROUND MOTION SET 2 121,050 m7fset3.acc GROUND MOTION SET 3 311,572 bytes Directory of CD FOR GEO.KBIP.02.06 REV.0Vni17juns ANALYSIS FOR THE MEDIAN PROFILE WITH EQ SET 1 10/29/2002 01:17p 10(2912002 01:17p 10/29/2002 01:22p 06/04/202 09:41a 06104/2002 09:41a 06104/2002 09:41a 06104/2002 09:41a 06104/2002 09:41a 06104/2002 09:41a 0614/2002 09.42a 0804/2002 09:42a 06104/2002 09:42a 10/22/2002 01:36a 10/22/2002 01:36a 10/22/2002 01:36a 06/0412002 09-40a 06104/2002 09:40a

<DIR>

<DIR>

<DIR>

Input 66,574 mrp p0g.ath COMPUTED SURFACE MOTION WITH 1.OG INPUT ACO 105,311 ml_1pg.out OUTPUT OF ANALYSIS WITH 1.OG INPUT ACC 29,901 mlp0g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.OG INPUT 66,574 ml-1p2g.ath COMPUTED SURFACE MOTION WITH 1.2G INPUT ACC 105,311 m1_1p2g.out OUTPUT OF ANALYSIS WITH 1.2G INPUT ACC 29,901 mp2g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.2G INPUT 66,574 ml1lp4g.ath COMPUTED SURFACE MOTION WITH 1.4G INPUT ACC 105,311 ml_1p4g.out OUTPUT OF ANALYSIS WITH 1.4G INPUT AGC 29,901 ml_1p4g.rmp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.4G INPUT 66,574 mllp6g.ath COMPUTED SURFACE MOTION WITH 1.6G INPUT ACC 105,311 mI1 p6g.out OUTPUT OF ANALYSIS WITH 1.6G INPUT ACC 29,901 ml_lp6g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.6G INPUT 66,574 mlplg.ath COMPUTED SURFACE MOTION WITH 0.IG INPUT ACC 105,311 ml.plg.out OUTPUT OF ANALYSIS WITH 0.1 INPUT ACC

06/04/2002 09:40a 0104/2002 09:40a 06/04/2002 09:40a 0610412002 09:40a 06104/2002 0940a 06/04/2002 09:40a 08104/2002 09 40a 06104/2002 0941a 06t04/2002 09:41a 06104J2002 09:41a 06/0412002 09:41a 06t04/2002 0941a 06/0412002 09:41a 0810412002 09:41a 06/04/2002 09:41a 0810412002 09:41a 060412002 09:41 a 06/0412002 09:41a 06/04/2002 09:41a 06104/2002 09-41a 06J04/2002 0941a 06t0412002 09.41a 08104'2002 09:41a 06/0412002 09:41a 06/04/2002 0941a 39 File(s)

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 81 of 196 Date: 11/06/02 29,901 mlplg.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.1G INPUT 66,574 mlp2g.ath COMPUTED SURFACE MOTION WITH 0.2G INPUT ACC 105,311 mlp2g.out OUTPUT OF ANALYSIS WITH 0.2G INPUT ACC 29,901 mlp2g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.2G INPUT 66,574 ml-p3g.ath COMPUTED SURFACE MOTION WITH 0.3G INPUT ACC 105,311 mlp3g.out OUTPUT OF ANALYSIS WITH 0.3G INPUT ACC 29,901 mlp3g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.3G INPUT 66,574 mlp4g.ath COMPUTED SURFACE MOTION WITH 0.4G INPUT ACC 105,311 mlp4g.out OUTPUT OF ANALYSIS WITH 0.4G INPUT ACC 29,901 mlp4g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.4G INPUT 66,574 mnlp5g.ath COMPUTED SURFACE MOTION WITH 0.5G INPUT ACC 105,311 mlpSg.out OUTPUT OF ANALYSIS WITH 0.5G INPUT ACC 29,901 mlp5g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.5G INPUT 66,574 mlp6g.ath COMPUTED SURFACE MOTION WITH 0.6G INPUT ACC 105,311 mlD6g.out OUTPUT OF ANALYSIS WITH 0.6B INPUT ACC 29,901 mlp6g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.6G INPUT 66,574 mlp7g.ath COMPUTED SURFACE MOTION WITH 0.7G INPUT ACC 105,311 mlp7g.out OUTPUT OF ANALYSIS WITH 0.7G INPUT ACC 29,901 mlp7g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.7G INPUT 66,574 ml.p8g.ath COMPUTED SURFACE MOTION WITH 0.8G INPUT ACC 105,311 ml_p8g.out OUTPUT OF ANALYSIS WITH 0.8G INPUT ACC 29,901 mlp8g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.8G INPUT 66,574 ml p9g.ath COMPUTED SURFACE MOTION WITH 0.9G INPUT ACC 105,311 mlp9g.out OUTPUT OF ANALYSIS WITH 0.9G INPUT ACC 29,901 mlp9g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.9G INPUT 2,623,218 bytes Directory of CD FOR GEO.HBIP.02.06 REV.0 mt17_runs'dnput 10129/2002 01:22p 10t29/2002 01:22p 060412002 07:57a 060412002 07:57a 0604/2002 07:57a 1 0222002 12 40a 0810412002 07:56a 06104/2002 07:56a 0810V2002 07:56a 06/04/2002 07:56a 06/04/2002 07:56a 06104/2002 07:56a 08104/2002 07:56a 0J04/2002 07:56a 0104/2002 07:56a 13 File(s)

<DIR>

<DIR>

11,221 ml p0g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 1.OG 11,221 m1_1p2g.inp INPUT FILE FOR GROUND MOTION SCALED TO 1.2G 11,221 mll p4g.inp INPUT FILE FOR GROUND MOTION SCALED TO 1.4G 11,221 m 1p6g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 1.6G 11,221 mlplg.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.10 11,221 mlp2g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.1G 11,221 mlp3g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.3G 11,221 mlp4g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.4G 11,221 m1_p5g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.5G 11.221 m1 p6g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.6G 11,221 mlp7g.Ip INPUT FILE FOR GROUND MOTION SCALED TO 0.7G 11,221 mlp8g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.8G 11,221 m-1p9g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.9G 145,873 bytes Directory of CD FOR GEO.HBIP.02.06 REV.0 \\m18_runs ANALYSIS FOR THE MEDIAN PROFILE WITH EQ SET 2 10129/2002 01:16p 10/2912002 01:16p 10/29/2002 01:22p 06/04/2002 09-.47a 06104/2002 09:47a 0810412002 09 47a 08104/2002 09:47a 081042002 09:47a 06//2002 09:47a 04/W2002 09:48a 06/04/2002 09:48a 06/0412002 09:48a 10122/2002 01:36a 1012212002 01:36a 102/2002 01:36a 06104/2002 09.45a 06/04/2002 09:45a 060412002 09:45a 06104/2002 09.45a

<DIR>

<DIR>

<DIR>

input 121,573 mlp0g.ath COMPUTED SURFACE MOTION WITH 1.0G INPUT ACC 105,311 m_1pOg.out OUTPUT OF ANALYSIS WITH 1.0G INPUT ACC 29,901 m_1pOg.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.0G INPUT 121,573 m1lp2g.ath COMPUTED SURFACE MOTION WITH 1.2G INPUT ACC 105,311 ml_ p2g.out OUTPUT OF ANALYSIS WITH 1.2G INPUT ACC 29,901 mp2g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.20 INPUT 121,573 mIlp4g.ath COMPUTED SURFACE MOTION WITH 1.4G INPUT ACC 105,311 mllp4g.out OUTPUT OFANALYSIS WITH 1.4G INPUT ACC 29,901 mltp4g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.4G INPUT 121,573 ml1 p6g.ath COMPUTED SURFACE MOTION WITH 1.6G INPUT ACC 105,311 ml_ p6g.out OUTPUT OF ANALYSIS WITH 1.6G INPUT ACC 29,901 m1l-p6g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.6G INPUT 121,573 m_p1g.ath COMPUTED SURFACE MOTION WITH 0.1 G INPUT ACC 105,311 mlpl g.out OUTPUT OF ANALYSIS WITH 0.1 G INPUT ACC 29,901 mplg.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.1G INPUT 121,573 ml-p2g.ath COMPUTED SURFACE MOTION WITH 0.2G INPUT ACC

06/04/2002 09:45a 06104/2002 0945a 06104/2002 09:45a 06/04/2002 09:45a 06/04/2002 09:45a 06/04/2002 09:46a 06/04/2002 09:46a 06/04J2002 09:46a 06/04/2002 09:46a 06/04/2002 09:46a 06/04/2002 09:46a 06/042002 09:46a 06/04/2002 09:46a 06/04/2002 09:46a 06104J2002 09:46a 06/04/2002 09:46a 06/04/2002 09:46a 06/04/2002 09:47a 06/04/2002 09:47a 06/04/2002 09:47a 061/2002 09:47a 06/04/2002 09:47a 06/04/2002 09:47a 39 File(s)

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 82 of 196 Date: 1 1/06/02 105,311 mlp2g.out OUTPUT OF ANALYSIS WITH 0.2G INPUT ACC 29,901 mlp2g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 02G INPUT 121,573 ml1p3g.at COMPUTED SURFACE MOTION WITH 0.3G INPUT ACC 105,311 mlp3g.out OUTPUT OF ANALYSIS WITH 0.3G INPUT ACC 29,901 ml.p3g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.3G INPUT 121,573 mlp4g.ath COMPUTED SURFACE MOTION WITH 0.4G INPUT ACC 105,311 ml._p4g.out OUTPUT OF ANALYSIS WITH 0.4G INPUT ACC 29,901 mlp4g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.4G INPUT 121,573 ml_.p5g.ath COMPUTED SURFACE MOTION WITH 0.5G INPUT ACC 105,311 m1jp5g.out OUTPUT OF ANALYSIS WITH 0.5G INPUT ACC 29,901 mlp5g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.5G INPUT 121,573 mlp6g.ath COMPUTED SURFACE MOTION WITH 0.6G INPUT ACC 105,311 ml.p6g.out OUTPUT OF ANALYSIS WITH 0.6G INPUT ACC 29,901 mlp6g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.6G INPUT

.121,573 mlp7g.ath COMPUTED SURFACE MOTION WITH 0.7G INPUT ACC 105,311 mlp7g.out OUTPUT OF ANALYSIS WITH 0.7G INPUT ACC 29,901 mlp7g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.7G INPUT 121,573 mlp8g.ath COMPUTED SURFACE MOTION WITH 0.8G INPUT ACC 105,311 mlp~g.out OUTPUT OF ANALYSIS WITH 0.8G INPUT ACC 29,901 mlp8g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.8G INPUT 121,573 mlp9g.at) COMPUTED SURFACE MOTION WITH 0.9G INPUT ACC 105,311 m1_p9g.out OUTPUT OF ANALYSIS WITH 0.9G INPUT ACC 29,901 mlp9g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.9G INPUT 3,338,205 bytes Directory of CD FOR GEO.HBIP.02.06 REV.0 m18uns\\Input 10/29/2002 012p 1029/2002 01:22p 06/04/2002 07:59a 06/04/2002 07:59a 0604/2002 07:59a t122002 12:40a 06/04/2002 07:58a 06/04/2002 07:59a 06/04/2002 07:59a 06/04/2002 07:59a 06/42002 07:59a 06/04/2002 07:59a 06/04/2002 07:59a 06/04/2002 07:59a 06/04/2002 07:59a 13 File(s)

<DIR>

cDIR>

11,221 m1lpOg.Inp INPUT FILE FOR GROUND MOTION SCALED TO 1.OG 11,221 mllp2g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 12G 11,221 ml_1p4g.1np INPUT FILE FOR GROUND MOTION SCALED TO 1.4G 11,221 m_1p6g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 1.6G 11,221 ml-plg.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.1G 11,221 mlp2g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.1G 11,221 mp3g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.3G 11,221 mp4g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 4G 11,221 mp5g.inp INPUT LE FOR GROUND MOTION SCALED TO 0.5G 11,221 mp6g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.6G 11,221 mp7g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.7G 11,22Wp8g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.8G 11,221 mTp9g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.90 145,87 bytes Directory of CD FOR GEO.HBIP.02.06 REV.0 n19nuns ANALYSIS FOR THE MEDIAN PROFILE WITH EO SET 3 10/29/2002 01:16p 10292002 01:16p 1029/2002 01:22p 06/04/2002 09:56a 06/W2002 09:56a 06A04/2002 09:56a 06/04/2002 09:57a 06/04/2002 09:57a 06/04/2002 09:57a 06/042002 09:57a 06/02002 09:57a 06/04/2002 09 57a 10/22/2002 01:37a 1022/2002 01:37a 10/222002 01:37a 06/04/2002 09:54a 06/04/2002 09:54a 06/04/2002 09:54a 06/04/2002 09:54a 06/04/2002 09-54a 06/04/2002 08 54a

<DIR>

<DIR>

<DIR>

Input 119,548 ml-lp0g.ath COMPUTED SURFACE MOTION WITH 1.0G INPUT ACC 105,311 m1_1pOg.out OUTPUT OF ANALYSIS WITH 1.OG INPUT ACC 29,901 mlpOg.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.0G INPUT 119,548 m1lp2g.ath COMPUTED SURFACE MOTION WITH 1.2 INPUT ACC 105,311 ml-lp2g.out OUTPUT OF ANALYSIS WITH 1.2G INPUT ACC 29,901 m1lp2g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.2G INPUT 119,548 mllp4g.ath COMPUTED SURFACE MOTION WITH 1.4G INPUT ACC 105,311 m1lp4g.out OUTPUT OF ANALYSIS WITH 1.4G INPUT ACC 29,901 mllp4g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.4G INPUT 119,548 m1_1p6g.afl COMPUTED SURFACE MOTION WITH 1.6G INPUT ACC 105,311 mllp6g.out OUTPUT OF ANALYSIS WITH 1.6G INPUT ACC 29,901 m1_1p6g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.6G INPUT 119,548 mlplg.ath COMPUTED SURFACE MOTION WITH 0.1G INPUT ACC 105,311 mlplg.out OUTPUTOFANALYSIS WITH 0.1G INPUTACC 29,901 mlp1g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.1 G INPUT 119,548 mlp2g.ath COMPUTED SURFACE MOTION WITH 0.2G INPUT ACC 105,311 mlp2g.out OUTPUT OF ANALYSIS WITH 0.2G INPUT ACC 29,901 mlp2g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.2G INPUT

06/04/2002 09:55a 06/04/2002 09:55a 06/0412002 09:55a 06/04/2002 09:55a 0604/2002 09-55a 06/04/2002 09:55a 06/04/2002 09:55a 06/0412002 09:55a 06104/2002 09:55a 06/04/2002 09:55a 06/04/2002 09:55a 06/04/2002 09:55a 06/12002 09:56a 06/04/2002 09:58a 06/04/2002 09:58a 06/042002 09:56a 06/04/2002 09:56a 0610412002 09 5a 06/04/2002 09:56a 06/04/2002 09:56a 00412002 09:56a 39 File(s)

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 83 of 196 Date: 11/06/02 119,548 mlp3g.ath COMPUTED SURFACE MOTION WITH 0.3G INPUT ACC 105,311 mlp3g.out OUTPUT OF ANALYSIS WITH 0.3G INPUT ACC 29,901 ml1p3g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.3G INPUT 119,548 m1_P4g.ath COMPUTED SURFACE MOTION WITH 0.4G INPUT ACC 105,311 mlp4g.out OUTPUT OF ANALYSIS WITH 0.4G INPUT ACC 29,901 mlp4g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.4G INPUT 119,548 mlp5g.ath COMPUTED SURFACE MOTION WITH 0.5G INPUT ACC 105,311 ml.p5g.out OUTPUT OF ANALYSIS WITH 0.5G INPUT ACC 29,901 m1_p5g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.5G INPUT 119,548 mlp6g.ath COMPUTED SURFACE MOTION WITH 0.6¢ INPUT ACC 105,311 mlp6goout OUTPUT OF ANALYSIS WITH 0.6G INPUT ACC 29,901 m1_p6grsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.6G INPUT 119,548 mlp7g.ath COMPUTED SURFACE MOTION WITH 0.7G INPUT ACC 105,311 mlp7g.out OUTPUT OF ANALYSIS WITH 0.7G INPUT ACC 29,901 mlp7g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.7G INPUT 119,548 mlp8g.at COMPUTED SURFACE MOTION WITH 0.86 INPUT A¢C 105,311 mlpg.out OUTPUT OF ANALYSIS WITH 0.8G INPUT ACC 29,901 mtp8g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.8G INPUT 119,548 ml.p9g.ath COMPUTED SURFACE MOTION WITH 0.90 INPUT ACC 105,311 mlp9g.out OUTPUT OF ANALYSIS WITH 0.96 INPUT ACC 29,901 mlp9g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.9G INPUT 3,311,880 bytes Directory of CD FOR GEO.HBIP.02.06 REV.0nl9_unsUnput 10/29/2002 01:22p 10/2912002 01: 2 2p 06/04/2002 1227a 06/04/2002 1227a 06/0412002 12:27a 10Z22t2002 12.41a 06/04/2002 12:25a 06/0412002 1225a 06/0412002 1225a 06/04t2002 1225a 06/042002 1226a 06/0412002 12:26a 06/0412002 12.26a 06/0412002 12.26a 0604/2002 1226a 13 File(s)

<DIR>

<DIR>

11,221 m1_-1p0g.kp INPUT FILE FOR GROUND MOTION SCALED TO 1.OG 11,221 ml1p2g.1np INPUT FILE FOR GROUND MOTION SCALED TO 1.2G 11,221 m1_1p4g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 1.4G 11,221 ml_p6g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 1.6G 11,221 ml.plg.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.16 11,221 mlp2gInp INPUT FILE FOR GROUND MOTION SCALED TO 0.1 G 11.221 mlp3g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.3G 11,221 m1_p4g.np INPUT FILE FOR GROUND MOTION SCALED TO 0.4G 11.221 mlpsg.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.5G 11,221 mlp6g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.6G 11,221 mlp7g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.7G 11,221 m1 p8g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.8G 11,221 mp9g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.9G 145,873 bytes Direcoy of CD FOR GEO.HBIP.02.06 REV.0 um27_runs ANALYSIS FOR THE LOWER BOUND PROFILE WITH EQ SET 1 1012912002 01:15p 10/29t2002 01:15p 10129t2002 01:2 3p 06t0412002 09:43a 06/04t2002 0943a 06/04/2002 09 43a 06/042002 09:43a 06/04Z2002 09:43a 06042002 09:43a 060412002 09:43a 06/04/2002 09:43a 06t04t2002 09:43a 10/2212002 01:36a 10122/2002 01:36a 12212002 01:36a 06/0412002 09:42a 06/04/2002 09:42a 06/04J2002 09:42a 06/04/2002 09:42a 06/04/2002 09:42a 06/0412002 09:42a 06/042002 09:42a

<DIR>

<DIR>

<DIR>

Input 66,574 m2_lpOg.ath COMPUTED SURFACE MOTION WITH 1.0G INPUT ACC 105,311 m2_Ip0gout OUTPUT OF ANALYSIS WITH 1.06 INPUT ACC 29,901 m2_lpOg.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.0G INPUT 66,574 m2_1 p2g.ath COMPUTED SURFACE MOTION WITH 1.2G INPUT ACC 105,311 m2_lp2g.out OUTPUT OF ANALYSIS WITH 1.26 INPUT ACC 29,901 m2.jp2g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.2G INPUT 66,574 m2_lp4g.ath COMPUTED SURFACE MOTION WITH 1.4G INPUT ACC 105,311 m2_lp4g.out OUTPUT OF ANALYSIS WITH 1.46 INPUT ACC 29,901 m2_1p4g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.4G INPUT 68,574 m2_lp6g.ath COMPUTED SURFACE MOTION WITH 1.6G INPUT ACC 105,311 m2_ lp~g.out OUTPUT OF ANALYSIS WITH 1.66 INPUT ACe 29,901 m2_lpfgtrsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.6G INPUT 66,574 m2..pl g.alh COMPUTED SURFACE MOTION WITH 0.1G INPUT ACC 105,311 m2_pl g.out OUTPUT OF ANALYSIS WITH 0.1G INPUT AGC 29,901 m2_plg.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.1G INPUT 66,574 m2.p2g.ath COMPUTED SURFACE MOTION WITH 0.2G INPUT ACC 105,311 m2jp2g.out OUTPUT OF ANALYSIS WITH 0.2G INPUT ACC 29,901 m2_p2g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.2G INPUT 68,574 m2.p3g.ath COMPUTED SURFACE MOTION WITH 0.3G INPUT ACC

06/04/2002 09:42a 06/0412002 09:42a 06/04/2002 09:42a 06/04/2002 09:42a 06104/2002 09:42a 06104/2002 09:42a 06J0412002 09:42a 06/04/2002 09:42a 06/04/2002 09:42a 06/0412002 09:42a 06/04/2002 09:42a 06104/2002 09:42a 06/0412002 09:42a 061042002 09:42a 0604/2002 09:43a 06/04/2002 09 43a 06/04/2002 09:43a 06/04/2002 09:43a 06/04/2002 09:43a 06104/2002 09:43a 39 File(s)

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 84 of 196 Date: 11/06/02 105,311 m2.p3g.out OUTPUT OF ANALYSIS WITH 0.3G INPUT ACC 29,901 m2_p3g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.3G INPUT 66,574 m2p4g.at COMPUTED SURFACE MOTION WITH 0.4G INPUT ACC 105,311 m2.p4g.out OUTPUT OF ANALYSIS WITH 0.4G INPUT ACC 29,901 m2.p4g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.4G INPUT 66,574 m2.p5g.ath COMPUTED SURFACE MOTION WITH 0.5G INPUT ACC 105,311 m2_p5g.out OUTPUT OF ANALYSIS WITH 0.5G INPUT ACC 29,901 m2_p5g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.5G INPUT 66,574 m2_p6g.ath COMPUTED SURFACE MOTION WITH 0.6G INPUT ACC 105,311 m2_p6g.out OUTPUT OF ANALYSIS WITH 0.6G INPUT ACC 29,901 m2_p6g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.6G INPUT 66,574 m2_p7g.ath COMPUTED SURFACE MOTION WITH 0.7G INPUT ACC 105,311 m2_p7g.out OUTPUT OF ANALYSIS WITH 0.7G INPUT ACC 29,901 m2_p7g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.7G INPUT 66,574 m2p8g.at COMPUTED SURFACE MOTION WITH 0.8G INPUT ACC 105,311 m2.p8g.out OUTPUT OF ANALYSIS WITH 0.8G INPUT ACC 29,901 m2_p8g.nsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.8G INPUT 66,574 m2_p9g.ath COMPUTED SURFACE MOTION WITH 0.9G INPUT ACC 105,311 m2_p9g.out OUTPUT OF ANALYSIS WITH 0.9G INPUT ACC 29,901 m2_p9g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.9G INPUT 2,623,218 bytes Directory of CD FOR GEO.HBIP.02.06 REV.0 \\m27runs\\input 10/29/2002 01 :23p 10/29/2002 01:23p 06104/2002 08:20a 06/04/2002 08.20a 06/04/2002 0820a 10t22/2002 12:47a 06/0412002 08:19a 06/0412002 08:19a 06/0412002 08:t9a 06/04/2002 08:19a 06104/2002 08:20a 06/04/2002 08:20a 06/0412002 08:20a 060412002 0820a 06042002 08:20a 13 File(s)

<DIR>

<DIR>

11,217 m2_1 p0g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 1.0G 11,217 m2_1p2g.inp INPUT FILE FOR GROUND MOTION SCALED TO 1.2G 11,217 m2_1p4g.1np INPUT FILE FOR GROUND MOTION SCALED TO 1.4G 11,217 m2_lp6g.inp INPUT FILE FOR GROUND MOTION SCALED TO 1.6G 11,217 m2_plg.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.1 G 11,217 m2 p2g.Inp INPUT FILE FOR GROUND MOTION SCALED TO.1(G 11,217 m2_p3g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.3G 11,217 m2.p4g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.4G 11,217 m2..p5g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.5G 11,217 m2.p6g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.6G 11,217 m2_p7g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.7G 11,217 m2 p8g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.8G 11,217 m2_p9g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.9G 145,B21 bytes

  • Directory of CD FOR GEO.HIP.02.06 REV.0 m28_runs ANALYSIS FOR TE LOWER BOUND PROFILE WIT EQ SET 2 10/29/2002 01:14p 10/29/2002 01:14p 10/2912002 01:23p 0604/2002 09:50a 06104J2002 09:50a 06/04J2002 09:50a 0610412002 09:50a 06/04J2002 09:50a 0610412002 09:50a 06/04/2002 09:51a 06/0412002 09:51a 06/04/2002 09:51a 10/2212002 01:37a 10/22/2002 01:37a 1012212002 01:37a 06/04/2002 09:4a 0614/2002 09:48a 06/04/2002 09:48a 06/04/2002 09:48a 06104/2002 09:48a 06t04/2002 09.48a 06/04/2002 09:48a 06104f2002 09:48a

<DIR>

<DIR>

<DIR>

Input 121,573 m21pOg.ath COMPUTED SURFACE MOTION WITH 1.0G INPUT ACC 105,311 m2_lp0g.out OUTPUT OF ANALYSIS WITH.OG INPUTACC 29,901 m2_lpOy.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH.OG INPUT 121,573 m2_lp2g.ath COMPUTED SURFACE MOTION WITH 1.2G INPUT ACC 105,311 m2_1lp2g.out OUTPUT OF ANALYSIS WITH 1.2& INPUT ACC 29,901 m2_lp2g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.2G INPUT 121,573 m2_1lp4g.ath COMPUTED SURFACE MOTION WITH 1.4G INPUT ACC 105,311 m2_lp4g.out OUTPUT OF ANALYSIS WITH 1.4G INPUT ACC 29,901 m2_lp4g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.4G INPUT 121,573 m2.jp6g.ath COMPUTED SURFACE MOTION WITH 1.6G INPUT ACC 105,311 m2_1p6g.out OUTPUT OF ANALYSIS WITH 1.6G INPUT ACC 29,901 m2_lp6g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH.6G INPUT 121,573 m2_p1 g.ath COMPUTED SURFACE MOTION WITH 0.1(G INPUT ACC 105,311 m2_plg.out OUTPUT OF ANALYSIS WITH 0.1G INPUT ACC 29,901 m2_plg.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.1G INPUT 121,573 m2_p2g.ath COMPUTED SURFACE MOTION WITH 0.2& INPUT ACC 105,311 m2_p2g.out OUTPUT OFANALYSIS WITH 0.20 INPUT ACC 29,901 m2_p2g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.2G INPUT 121,573 m2-p3g.ath COMPUTED SURFACE MOTION WITH 0.3G INPUT ACC 105,311 m2p3g.out OUTPUT OF ANALYSIS WITH 0.3G INPUT ACC

06/04/2002 09:48a 06/04/2002 09:49a 0610412002 09:49a 0610412002 09:49a 06/04/2002 0949a 06/04/2002 09:49a 06/0412002 09:49a 06/04/2002 09 49a 06/04/2002 09 49a 06/04/2002 09 49a 06104/2002 09:49a 06/04/2002 09 49a 06/04/2002 09:49a 06/04/2002 09:50a 06104/2002 09:50a 06/04/2002 09:S0a 06/04/2002 09:50a 06/04/2002 09.50a 06/04/2002 09 50a 39 FIle(s)

Calc Number. GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 85 of 196 Date: 11/06/02 29,901 m2.p3g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.3G INPUT 121,573 m2_p4g.ath COMPUTED SURFACE MOTION WITH 0.4G INPUT ACC 105,311 m2.p4gout OUTPUT OF ANALYSIS WITH 0.4G INPUT ACC 29,901 m2jp4g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.4G INPUT 121,573 m2_p5g.ath COMPUTED SURFACE MOTION WITH 0.5G INPUT ACC 105,311 m2_p5g.out OUTPUT OF ANALYSIS WITH 0.5G INPUT ACC 29,901 m2 p5g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.5G INPUT 121.573 m2_p6g.ath COMPUTED SURFACE MOTION WITH 0.6G INPUT ACC 105,311 m2_p6g.out OUTPUT OF ANALYSIS WITH 0.6G INPUT ACC 29,901 m2_p6g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.6G INPUT 121,573 m2_p7g.ath COMPUTED SURFACE MOTION WITH 0.7G INPUT ACC 105,311 m2_p7g.out OUTPUT OF ANALYSIS WITH 0.7G INPUT ACC 29,901 m2_p7g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.7G INPUT 121,573 m2p8g.ath COMPUTED SURFACE MOTION WITH 0.8G INPUT ACC 105,311 m2p8g.out OUTPUT OF ANALYSIS WITH 0.8G INPUT ACC 29,901 m2_p8g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.8G INPUT 121,573 m2_p9g.ath COMPUTED SURFACE MOTION WITH 0.9G INPUT ACC 105,311 m2_p9g.out OUTPUT OF ANALYSIS WITH 0.9G INPUT ACC 29,901 m2_p9g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.9G INPUT 3,338,205 bytes Directory of CD FOR GEO.HBIP.02.06 REV.0 \\n28_runsnput 10/2612002 01 2 3p 10129/2002 01 23p 06/04/2002 08-22a 06/04/2002 0822a 06/04/2002 08:22a 10/22/2002 12 47a 06/042002 08:21a 06/04/2002 0821a 06/04/2002 08:21a 06/04/2002 08:22a 06/04/2002 08:22a 06/04/2002 08:22a 0604/2002 0822a 0U04/2002 08:22a 06/04/2002 08:22a 13 File(s)

<DIR>

<DIR 11,217 m2_1pOg.inp INPUT FILE FOR GROUND MOTION SCALED TO 1.OG 11,217 m2_1 p2g.inp INPUT FILE FOR GROUND MOTION SCALED TO 1.2G 11,217 m2_1p4g.inp INPUT FILE FOR GROUND MOTION SCALED TO 1.4G 11,217 m2_lp6g.inp INPUT FILE FOR GROUND MOTION SCALED TO 1.6G 11,217 m2 pl g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.1G 11,217 m2_p2g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.1G 11,217 m2_p3g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.3G 11,217 m24p4g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.4G 11,217 m2_p5g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.5G 11,217 m2_p6g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.6G 11,217 m2_p7g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.7G 11,217 m2_p8g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.8G 11,217 m2_p9g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.9G 145.821 bytes Directory of CD FOR GEO.HBIP.02.06 REV.0 \\m29jsrus ANALYSIS FOR THE LOWER BOUND PROFILE WITH EQ SET 3 10/29/2002 01:14p 10/29/2002 01:14p 10/29/002 01:23p 06/04/2002 09,59a 06/04/2002 09:59a 06J042002 095ga 06/0412002 10.00a 06104/2002 1000a 06/04/2002 1000a 06/042002 10:00a 06/04/2002 10:00a 06/0412002 1000a 10/22/2002 01:37a I =0222002 01:37a 1022/2002 01:37a 06/04/2002 09:57a 06/0412002 09:57a 06104/2002 09:57a 06/04/2002 09:57a 06/0412002 09:57a 06/04/2002 09:57a 06/04/2002 09:58a 06/04/2002 09:58a 0604/2002 09:58a

<DIR>

<DIR>

<DIR>

input 119,548 m2_1 pOg.ath COMPUTED SURFACE MOTION WITH 1.OG INPUT ACC 105,311 m2j pOg.out OUTPUT OF ANALYSIS WITH 1.OG INPUT ACC 29,901 m2_1pOg.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.06 INPUT 119,548 m2_1p2g.ath COMPUTED SURFACE MOTION WITH 1.2G INPUT ACC 105,311 m2jp2g.out OUTPUT OF ANALYSIS WITH 1.2G INPUT ACC 29,901 m2_lp2g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.2G INPUT 119,548 m2._lp4g.ath COMPUTED SURFACE MOTION WITH 1.4G INPUT ACC 105,311 m2_1p4g.out OUTPUT OF ANALYSIS WITH 1.4G INPUT ACC 29,901 m2_lp4g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.40 INPUT 119,548 m2p6g.ath COMPUTED SURFACE MOTION WITH 1.6G INPUTACC 105,311 m2j p6g.out OUTPUT OF ANALYSIS WITH 1.6G INPUT ACC 29,901 m2_1p6g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.66 INPUT 119,548 m2_plg.ath COMPUTED SURFACE MOTION WITH 0.1G INPUT ACC 105,311 m2_plg.out OUTPUT OF ANALYSIS WITH 0.1G INPUT ACC 29,901 m2_plg.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.1 G INPUT 119,548 m2_p2g.ath COMPUTED SURFACE MOTION WITH 0.2G INPUT ACC 105,311 m2_p2g.out OUTPUT OF ANALYSIS WITH 0.2G INPUT ACC 29,901 m2_p2g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.2G INPUT 11 9,548 m2jp3g.ath COMPUTED SURFACE MOTION WITH 0.3G INPUT ACC 105,311 m24D3g.out OUTPUT OF ANALYSIS WITH 0.36 INPUT ACC 29,901 m2_p3g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.3G INPUT

06/04/2002 09:58a 06104/2002 09:58a 06104/2002 09:58a 06104/2002 09:58a 06/04/2002 09:58a 06/04/2002 09:58a 06/04/2002 09:58a 06104/2002 09:58a 0610412002 09:58a 06104/2002 09:59a 06/04/2002 09:59a 0610412002 09:59a 06/04/2002 09:59a 0610412002 09:59a 0610412002 09:59a 0610412002 09:59a 060412002 09:59a 06/04/2002 09:59a 39 File(s)

Calc Number GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 86 of 196 Date: 11/06/02 119,548 m2_p4g.ath COMPUTED SURFACE MOTION WITH 0.4G INPUT ACC 105,311 m2p4g.out OUTPUT OF ANALYSIS WITH 0.4G INPUT ACC 29,901 m2_p4g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.4G INPUT 119,548 m2_p5g.ath COMPUTED SURFACE MOTION WITH 0.5G INPUT ACC 105,311 m2_p5g.out OUTPUT OF ANALYSIS WITH 0.5G INPUT ACC 29,901 m2_p5g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.56G INPUT 119,548 m2jp6g.ath COMPUTED SURFACE MOTION WITH 0.6G INPUT ACC 105,311 m2_p6g.out OUTPUT OF ANALYSIS WITH 0.6G INPUT ACC 29,901 m2_p6g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.6G INPUT 119,548 m2_p7g.ath COMPUTED SURFACE MOTION WITH 0.7G INPUT ACC 105.311 m2_p7g.out OUTPUT OF ANALYSIS WITH 0.7G INPUT ACC 29,901 m2_p7g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.7G INPUT 119,548 m2_p8g.ath COMPUTED SURFACE MOTION WITH 0.8G INPUT ACC 105,311 m2_p8g.out OUTPUT OF ANALYSIS WITH 0.8G INPUT ACC 29,901 m2_p8g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.8G INPUT 119,548 m2_p9g.ath COMPUTED SURFACE MOTION WITH 0.9G INPUT ACC 105,311 m2_p9g.out OUTPUT OF ANALYSIS WITH 0.9G NPUT ACC 29,901 m2_p9g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.9G INPUT 3,311,880 bytes Directory of CD FOR GEO.HBIP.02.06 REV.0 m29_.runs~Input 10/29/2002 01:23p 10129/2002 01.23p 0610412002 12:32a 0604/002 12.33a 06/0412002 1233a 1 022002 1247a 06104/2002 12.33a 06042002 1233a 0610412002 1233a 06102002 12:34a 0604/2002 12:34a 06/04/2002 12:34a 06104/2002 12:35a 0642002 1235a 06104/2002 1235a 13 File(s)

<DIR>

<DIR>

11,217 m2_1 p0g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 1.OG 11,217 m2_1 p2g.Ip INPUT FILE FOR GROUND MOTION SCALED TO 12G 11,217 m2_1 p4g.inp INPUT FILE FOR GROUND MOTION SCALED TO 1.4G 11,217 m2_lp6g.hp INPUT FILE FOR GROUND MOTION SCALED TO 1.6G 11,217 m2_pl g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.1G 11,217 m2_p2g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.1 G 11,217 m2_p3g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.3G 11,217 m2.p4g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.4G 11,217 m2.pSg.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.5G 11,217 m2.p6g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.6G 11,217 m2.p7g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.7G 11,217 m2_p8g.1np INPUT FILE FOR GROUND MOTION SCALED TO 0.8G 11,217 mr2_p9g.hnp INPUT FILE FOR GROUND MOTION SCALED TO 0.9G 145,821 bytes Directory of CD FOR GEO.HBIP.02.06 REV.0 \\n37-runs ANALYSIS FOR THE UPPER BOUND PROFILE WITH EQ SET 1 10/29/2002 01:14p 10/29/2002 01:14p 10/29/2002 01:24p 06/0412002 09:44a 0610412002 09:44a 0610412002 0944a 06/04/2002 09:44a 06/042002 09:44a 06104J2002 09:44a 06/04/2002 09:45a 06/0412002 09:45a 06/04/2002 09:45a 10/22/2002 01:36a 10/22/2002 01:36a 10/22/2002 01:36a 06/04/2002 09:43a 0610412002 09:43a 06104/2002 09:43a 06/04/2002 09:43a 06/04/2002 09:43a 06/2002 09:43a 06t04/2002 09:43a 06/0412002 09:43a 06/04)2002 09:43a 06/0412002 09:44a

<DIR>

<DIR>

cDIR>

Input 66,574 m3j1p0g.ath COMPUTED SURFACE MOTION WITH 1.OG INPUT ACC 105,311 m3_1 pOg.out OUTPUT OF ANALYSIS WITH 1.0G INPUT ACC 29,901 m3_1pOg.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.0G INPUT 66,574 m3_lp2g.ath COMPUTED SURFACE MOTION WITH 1.2G INPUT ACC 105,311 m3_1p2g.out OUTPUT OF ANALYSIS WITH 1.2G INPUT ACC 29,901 m3_1 p2g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.2G INPUT 66,574 m3_1 p4g ath COMPUTED SURFACE MOTION WITH 1.4G INPUT ACC 105,311 m3_1p4g.out OUTPUT OF ANALYSIS WITH 1.4G INPUT ACC 29,901 m3_lp4g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.4G INPUT 66,574 m3_1p6g ath COMPUTED SURFACE MOTION WITH 1.6G INPUT ACC 105,311 m3_lp6g.out OUTPUT OF ANALYSIS WITH 1.6G INPUT ACC 29,901 m3_1p6g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH.6G INPUT 66,574 m3_p1 g.ath COMPUTED SURFACE MOTION WITH 0.1G INPUT ACC 105,311 m3_plg.out OUTPUT OF ANALYSIS WITH 0.1G INPUT ACC 29,901 m3..plg.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.1G INPUT 66,574 m3.p2g.ath COMPUTED SURFACE MOTION WITH 0.2G INPUT ACC 105,311 m3_p2g.out OUTPUT OF ANALYSIS WITH 0.2G INPUT ACC 29,901 m3_p2g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.2G INPUT 66,574 m3..p3g.ath COMPUTED SURFACE MOTION WITH 0.3G INPUT ACC 105,311 m3_p3g.out OUTPUT OF ANALYSIS WITH 0.3G INPUT ACC 29,901 m3_p3g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.3G INPUT 66,574 m3_p4g.ath COMPUTED SURFACE MOTION WITH 0.4G INPUT ACC

0604/2002 09:44a 06(04/2002 09:44a 06/04/2002 09:44a 06104/2002 09:44a 06/04/2002 09:44a 06/04/2002 09:44a 06/04/2002 09:44a 0B104/2002 09.44a 06(04U2002 09:44a 06104/2002 09-44a 08/04/2002 09 44a 06104/2002 09:44a 06(0412002 09:44a 06(04/2002 09:44a 06/04/2002 09:44a 06104/2002 09:44a 06(04/2002 09:44a 39 File(s)

Calc Number GEO.HBIP.02.06 Rev Number: 0 Sheet Number 87 of 196 Date: 11/06/02 105,311 m3p4gout OUTPUT OF ANALYSIS WITH 0.4G INPUT ACC 29,901 m3_p4g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.4G INPUT 66,574 m3_p5g.ah COMPUTED SURFACE MOTION WITH 0.5G INPUT ACC 105,311 m3_pg.out OUTPUT OF ANALYSIS WITH 0.5G INPUT ACC 29,901 m3_p5g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.5G INPUT 66,574 m3.p6g.ath COMPUTED SURFACE MOTION WITH 0.6G INPUT ACC 105,311 m3_p6g.out OUTPUT OF ANALYSIS WITH 0.6G INPUT ACC 29.901 m3.peg.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.6G INPUT 68,574 m3.p7g.ath COMPUTED SURFACE MOTION WITH 0.7G INPUT ACC 105,311 m3.p7gout OUTPUT OF ANALYSIS WITH 0.7G INPUT ACC 29,901 m3_p7g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.7G INPUT 66,574 m3_p8gath COMPUTED SURFACE MOTION WITH 0.8G INPUT ACC 105,311 m3 p8g.out OUTPUT OF ANALYSIS WITH 0.8G INPUT ACC 29,901 m3_p8g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.8G INPUT 66,574 m3.p9g.ath COMPUTED SURFACE MOTION WITH 0.9G INPUT ACC 105,311 m3_p9g.out OUTPUT OF ANALYSIS WITH 0.9G INPUT ACC 29,901 m3_p9g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.9G INPUT 2,623,218 bytes Directory of CD FOR GEO.HBIP.02.06 REV.0 \\m37-runs\\Input 10/29/2002 01:24p 10(29/2002 01:24p 06/04/2002 08:3Ba 06/04/2002 08:38a 06104/2002 08:3Ba 1(O2212002 12:50a 06104/2002 08.35a 0B04/2002 08:35a 06/04/2002 08:35a 0610412002 08:35a 0610412002 08:35a 06(04/2002 08:36a 06(042002 08:36a O604/2002 08:36a 06/042002 08:3Ba 13 File(s)

<DIR>

<DIR>

11,223 m3_1p0g.inp INPUT FILE FOR GROUND MOTION SCALED TO 1.OG 11,223 m3_1 p2g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 1.2G 11,223 m3_1 p4g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 1.4G 11,223 m3_1 p~g.inp INPUT FILE FOR GROUND MOTION SCALED TO 1.60 11,223 m3.plg.kip INPUT FILE FOR GROUND MOTION SCALED TO 0.1(G 11,223 m3_p2g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.1G 11,223 m3_p3g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.3G 11,223 m3_p4g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.4G 11223 m3.p5g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.5G 11,223 m3_p6g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.6G 11,223 m3.p7g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.75 11,223 m3_p8g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.8G 11,223 m3_p9g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.9G 143,899 bytes Directory of CD FOR GEO.HBIP.02.06 REV.0 m38_uns ANALYSIS FOR THE UPPER BOUND PROFILE WITH EQ SET 2 1029/2002 01:13p 1029/2002 01:'3p 10/2912002 01:24p 0(042002 0953a 06(04/2002 09:53a 004/2002 09:53a 06(04/2002 09:53a 06(04/20 Q9:53a 06/04/2002 09:53a 06/04/2002 09:54a 06(04/2002 09:54a 06104/2002 09:54a 10/2212002 01:37a 10/22/2002 01:37a 101Z12002 01:37a 06(042002 09:51a 06104/2002 0951a 0604/2002 9:S1a 06/04/2002 09:51a 0604/2002 09:51a 06/04/2002 09:51a 06(04/2002 09:51a 06t04/2002 09:51a 06(04/2002 09:51a 06(04/2002 09:52a 0604/2002 09:52a

<DIR>

<DIR>

<DIR>

Inu 121,573 m3_1pOg.ath COMPUTED SURFACE MOTION WITH 1.O INPUT ACC 105,311 m3_1pOg.out OUTPUT OF ANALYSIS WITH 1.0G INPUT ACC 29,901 m3_1 pOg.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.OG INPUT 121,573 m3_lp2g.ath COMPUTED SURFACE MOTION WITH 1.20 INPUT ACC 105,311 m3_1p2g.out OUTPUT OF ANALYSIS WITH 12 INPUT ACC 29,901 m3_lp2g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.2G INPUT 121,573 m3_1p4g.ath COMPUTED SURFACE MOTION WITH 1.4( INPUT ACC 105,311 m3_1 p4g.out OUTPUT OF ANALYSIS WITH 1.4G INPUT ACC 29,901 m3_lp4g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.4G INPUT 121,573 m3_1p~g.ath COMPUTED SURFACE MOTION WITH 1.6G INPUT ACC 105,311 m3_1p6g.out OUTPUT OF ANALYSIS WITH 1.6G INPUT ACC 29,901 m3_1p6g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.6(G INPUT 121,573 m3pl g.ath COMPUTED SURFACE MOTION WITH o1(G INPUT ACC 105,311 m3_plg.out OUTPUT OF ANALYSIS WITH 0.1 G INPUT ACC 29,901 m3.plg.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.1(3 INPUT 121,573 m3.p2g.ath COMPUTED SURFACE MOTION WITH 0.2G INPUT ACC 105,311 m3 p2g.out OUTPUT OF ANALYSIS WITH 0.20 INPUT ACC 29,901 m3_p2g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.2 INPUT 121,573 m3_p3g.ath COMPUTED SURFACE MOTION WITH 0.3G INPUT ACC 105,311 m3_p3g.out OUTPUT OF ANALYSIS WITH 0.3G INPUT ACO 29,901 m3_p3g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.3 INPUT 121,573 m3p4g.ath COMPUTED SURFACE MOTION WITH 0.4G INPUT ACC 105,311 m3_p4g out OUTPUT OF ANALYSIS WITH 0.4G INPUT ACC

06104/2002 09:52a 06/04/2002 09:52a 06/04/2002 09:52a 06/04/2002 09:52a 06/0412002 09:52a 064/2002 09:52a 06/04/2002 09:52a 06/04/2002 09:52a 06/04/2002 09:52a 06/04/2002 09:52a 06/04/2002 09:53a 0604/2002 09:53a 06/04/2002 09:53a 06/0412002 09:53a 06/04/2002 09:53a 06/04/2002 09:53a 39 File(s)

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 88 of 196 Date: 11/06/02 29,901 m3.p4g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.4G INPUT 121.573 m3_p5g.ath COMPUTED SURFACE MOTION WITH 0.5G INPUT ACC 105,311 m3_p5g.out OUTPUT OF ANALYSIS WITH 0.5G INPUT ACC 29,901 m3_psg.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.5G INPUT 121,573 m3_p6g.ath COMPUTED SURFACE MOTION WITH 0.6G INPUT ACC 105,311 m3_p6g.out OUTPUT OF ANALYSIS WITH 0.6G INPUT ACC 29,901 m3_p6g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.6G INPUT 121,573 m3_p7g.ath COMPUTED SURFACE MOTION WITH 0.7G INPUT ACC 105,311 m3_p7g.cut OUTPUT OF ANALYSIS WITH 0.7G INPUT ACC 29,901 m3_p7g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.7G INPUT 121,573 m3_p8g.ath COMPUTED SURFACE MOTION WITH 0.8G INPUT ACC 105,311 m3_psg.out OUTPUT OF ANALYSIS WITH 0.8G INPUT ACC 29,901 m3_p8g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.8G INPUT 121,573 m3_p9g.ath COMPUTED SURFACE MOTION WITH 0.9G INPUT ACC 105,311 m3_p9g.out OUTPUT OF ANALYSIS WITH 0.9G INPUT ACC 29,901 m3_p9g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.9G INPUT 3,338,205 bytes Directory of CD FOR GEO.HBIP.02.06 REV.0 n38_uns\\input 10/29/2002 01 24p 10/29/2002 01:24p 06042002 08:38a 06/0412002 08:38a 06042002 08:38a 10/22/2002 12 51a 06/042002 08:37a 06/0412002 08:38a 06/0412002 08:38a 06/042002 08:38a 06104/2002 08:38a 06/04/2002 08:38a 06/0412002 08:38a 0610412002 08:38a 06/04/2002 08:38a 13 File(s)

<DIR>

<DIR>

11,223 m3_1pOg.Inp INPUT FILE FOR GROUND MOTION SCALED TO 1.0G 11,223 m3_lp2g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 1.2G 11,223 m3_lp4g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 1.AG 11, 123 m3_1p6g.inp INPUT FILE FOR GROUND MOTION SCALED TO 1.6G 11,223 m3.plg.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.1G 11,223 m3_jp2g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.1G 11,223 m3_p3g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.3G 11,223 m3_.p4g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.4G 11,223 m3.p5g.Inp INPUT FILE FOR GROUND MOTION SCALED TO 0.5G 11,223 m3_p6g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.6G 11,223 m3.p7g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.7G 11,223 m3_p8g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.8G 11.223 m3_p9g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.90 145,899 bytes Directory of CD FOR GEO.HBIP.02.06 REV.0 m39-uns ANALYSIS FOR THE UPPER BOUND PROFILE WITH EQ SET 3 10/29/2002 01:13p 1 02912002 01:13p 10/29/2002 01 24p 06/0412002 10:02a 0610412002 10:02a 06/0412002 10:02a 06/042002 10:03a 06/04t2002 10.03a 060412002 10:03a 06/0412002 10:03a 06/0412002 10:03a 06/0412002 10:03a 10/22/2002 01:38a 1012212002 01:38a 10/2212002 01 38a 06/12002 10:00a 06/0412002 10:00a 06/04/2002 10:00a 06/0412002 10:00a 06/0412002 10:00a 06/04/2002 10:00a 06104/2002 10:01a 06/04/2002 10:01a 06/04/2002 10:01a 06/04/2002 1001a 06/0412002 1001a 06/04/2002 10:01a

<DIR>

<DIR>

<DIR>

input 119,548 m3_1pOg.ath COMPUTED SURFACEMOTION WITH 1.0G INPUT ACC 105,311 m3_1pOg.out OUTPUT OF ANALYSIS WITH 1.0G INPUT ACC 29,901 m3_1pOg.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.0G INPUT 119,548 m3_lp2gath COMPUTED SURFACE MOTION WITH 1.2G INPUT ACC 105,311 m3_1p2g.out OUTPUT OF ANALYSIS WITH 1.20 INPUT ACC 29,901 m3_1p2g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.20 INPUT 119,548 m3_lp4g.ath COMPUTED SURFACE MOTION WITH 1.40 INPUT ACC 105,311 m3_1p4g.out OUTPUT OF ANALYSIS WITH 1.4G INPUT ACC 29,901 m3_1p4g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.4G INPUT 119.548 m3_1p6g.ath COMPUTED SURFACE MOTION WITH 1.60 INPUT ACC 105.311 m3_1 p6g.out OUTPUT OF ANALYSIS WITH 1.60 INPUT ACC 29,901 m3_1p6g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 1.6G INPUT 119,548 m3_plg.ath COMPUTED SURFACE MOTION WITH 0.1G INPUT ACC 105.311 m3_plg.out OUTPUT OF ANALYSIS WITH 0.1G INPUT ACC 29,901 m3_plg.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.1 G INPUT 119,548 m3_p2g.ath COMPUTED SURFACE MOTION WITH 0.2G INPUT ACC 105.311 m3_p2g.out OUTPUT OF ANALYSIS WITH 0.2G INPUT ACC 29,901 m3_p2g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.2G INPUT 119,548 m3p3g.ath COMPUTED SURFACE MOTION WITH 0.3G INPUT ACC 105.311 m3_p3g.out OUTPUT OFANALYSIS WITH 0.3G INPUTACC 29,901 m3_p3g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.3G INPUT 119,548 m3_jp4g.ath COMPUTED SURFACE MOTION WITH 0.4G INPUT ACC 105,311 m3p4g.out OUTPUT OF ANALYSIS WITH 0.4G INPUT ACC 29,901 m3.p4g.rsp RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.4G INPUT

06/04/2002 10:01a 0610412002 10:01a 06/04/2002 10:01a 06104/2002 10:01a 06/04/2002 10:01 a 06104/2002 10:01a 06/04/2002 10:02a 06/04/2002 10:02a 06/04/2002 10:02a 06/04/2002 10:02a 06/0412002 10:02a 060412002 10:02a 06/4/2002 10:02a 0610412002 10:02a 06/04/2002 10:02a 39 File(s) 119,548 m3_p5g.ath 105,311 m3_p5g.out 29,901 m3_p5g.rsp 119,548 m3p6g.ath 105,311 m3_p6g.out 29,901 m3.p6g.rsp 119,548 m3.p7g.ath 105,311 m3.p7g.out 29,901 m3_p7g.rsp 119,548 m3_p8gath 105,311 m3.p8g.out 29,901 m3_p8g.rsp 119,548 m3_p9g.ath 105,311 m3.p9g.out 29,901 m3_p9g.rsp 3,311,880 bytes Calc Number: GEO.HBIP.02.06 Rev Number 0 Sheet Number: 89 of 196 Date: 11/06/02 COMPUTED SURFACE MOTION WITH 0.5G INPUT ACC OUTPUT OF ANALYSIS WITH 0.5G INPUT ACC RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.5G INPUT COMPUTED SURFACE MOTION WITH 0.6G INPUT ACC OUTPUT OF ANALYSIS WITH 0.6G INPUT ACC RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.6G INPUT COMPUTED SURFACE MOTION WITH 0.7G INPUT ACC OUTPUT OF ANALYSIS WITH 0.7G INPUT ACC RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.7G INPUT COMPUTED SURFACE MOTION WITH 0.8G INPUT ACC OUTPUT OF ANALYSIS WITH 0.80 INPUT ACC RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.8G INPUT COMPUTED SURFACE MOTION WITH 0.9G INPUT ACC OUTPUT OF ANALYSIS WITH 0.9G INPUT ACC RESPONSE SPECTRUM OF SURFACE MOTION WITH 0.9G INPUT Directory of CD FOR GEO.HBIP.02.06 REV.0 W39jrunstinput 10/29/2002 01:24p 10/29/2002 01:24p 06/04/2002 1231a 08//2002 12.32a 06104/2002 12:32a 10/22/2002 12:51a 06/04/2002 1230a 06/04/2002 12:31a 06/04/2002 12:31a 06/04/2002 12:31a 06/04/2002 12:31a 06/04/2002 12:31a 06/04/2002 12:31a 06/04/2002 1231a 0604/2002 1231a 13 Fle(s)

<DIR>

<DIR>

11,223 m3_lp0g.inp INPUT FILE FOR GROUND MOTION SCALED TO 1.G0 11,223 m3_1 p2g.inp INPUT FILE FOR GROUND MOTION SCALED TO 1.2G 11,223 m3_1p4g.hip INPUT FILE FOR GROUND MOTION SCALED TO 1.4G 11,223 m3_1p6g.inp INPUT FILE FOR GROUND MOTION SCALED TO 1.6G 11,223 m3_ptg.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.1G 11,223 m3_p2g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.1 G 11,223 m3.p3g.lp INPUT FILE FOR GROUND MOTION SCALED TO 0.30 11,223 m3_p4g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.40 11,223 m3.p5ginp INPUT FILE FOR GROUND MOTION SCALED TO 0.5G 11,223 m3_p6ginp INPUT FILE FOR GROUND MOTION SCALED TO 0.60 11,223 m3_p7g.inp INPUT FILE FOR GROUND MOTION SCALED TO 0.7G 11,223 m3 p8gInp INPUT FILE FOR GROUND MOTION SCALED TO 0.8G 11,223 m3_p9g.np INPUT FILE FOR GROUND MOTION SCALED TO 0.9G 145,899 bytes Directory of CD FOR GEO.HBIP.02.06 REV.0 \\SHAKE96 Test Run 10/29/2002 01:48p 10/29/2002 01:48p 12/16/1989 02:18p 09/0611998 05:10a 11/28/1995 01:57p 10/29/2002 01:44p 5 File(s)

<DIR>

<DIR>

20,764 DIAM.ACC INPUT ACC TIME HISTORY FOR TEST RUN 307,712 SHAKE96.EXE SHAKE EXECUTABLE FILE USED FOR THIS PROJECT 4,143 Testnp INPUT FILE FOR TEST RUN 58,200 testout OURPUT FILE OF TEST RUN 451,241 bytes Directory of CD FOR GEO.HBIP.02.08 REV.0 \\SHAKE98 Test Run\\SHAKE9MS CERTIFIED SHAKE96S RUN RESULTS 10/29/2002 01 :47p 10/29/2002 01:47p 1216/1989 02:18p 07108/1992 01:24p 06103/2002 09:43a PROGRAM 04/061992 12.59p 05/0Y1996 05:43p 10l29/2002 01:40p 11/28/1995 01:57p 7 File(s)

<DIR>

<DIR>

20,764 DIAM.ACC INPUT AGC TIME HISTORY FOR TEST RUN 40,584 F77L3.EER Lahey Error Messages File 403 README.TXT README FILE DESCRIBING THE CERTIFIED SHAKE96S 183,076 RUN386.EXE Lahey DOS Extender File 205,746 SHAKE96S.EXE SHAKE96s Version 1.1 Executable File 58,200 SHAKE96S.OUT OUTPUT FILE OF TEST RUN USING SHAKE96S 4,143 TestInp INPUT FILE FOR TEST RUN 512,916 bytes Directoy of C:\\HBPP\\GEO.HBIP.02.06\\CD 02.08 Rev \\Northrldge 11105/2002 04:23p 11/05/2002 04:23p 10/29/2002 03:58p 10/29/02 03.29p

<DIR>

<DIR>

1,394 JEN022.050 5% daMped Sa for JEN022 19,062 JENO2AT2 A time history for JEN022

Calc Number: GEO.HBIP.02.06 Rev Nunber: 0 Sheet Number: 90 of 196 Date: 11/06/02 10/29/2002 03:40p 360 JEN022.IN Input file for SPCTLR for JEN022 10/20/2002 03:59p 1,394 JEN292.050 5% damped Sa for JEN292 1012912002 03:29p 19,061 JEN292AT2 Acc time history for JEN292 10/29/2002 03:38p 360 JEN292.IN Input file for SPCTLR for JEN292 10/29/2002 03:58p 1,394 NWHO90.050 5% damped Sa for NEW090 10/2912002 03:57p 31,118 NWH09O.AT2 Acc time history for NEW090 10/29/2002 03:58p 363 NWHO90.IN Input file for SPCTLR for NEWO90 10/29/2002 03:58p 1,394 NWH360.050 5% damped Sa for NWH270 10t29/2002 03:58p 31,066 NWH360AT2 Acc time history for NWH270 10/2912002 03:43p 363 NWH360.IN Input file for SPCTLR for NWH270 10/2112002 10:43a 1,394 RRS228.050 5% damped Sa for RRS228 07/13/2002 11:32a 46,920 RRS228AT2 Acc time history for RRS228 10/29/2002 03:41 p 363 RRS228.1N Input file for SPCTLR for RRS228 10/21/2002 10:43a 1,394 RRS318.050 5% damped Sa for RRS318 07/1312002 11-32a 46,920RRS31B.AT2 AectimehistoryforFIRS318 10/2112002 10 17a 363 RRS318.IN Input file for SPCTLR for RRS318 10/21/2002 10:43a 1,394SCEOI8.050 5%dampedSaforSCE0t8 0713/2002 11 :32a 125,076 SCEO18.AT2 Ac time history for SCE018 10t21t2002 10:17a 363SCE018.IN InputfileforSPCTLRforSCE018 10/21/2002 10:43a 1,394 SCE288.050 5% damped Sa for SCE288 07/13/2002 11:32a 125,076 SCE288.AT2 Aco time history for SCE288 10t2112002 10:18a 363 SCE28.IN Input file for SPCTLR for SCE28 10/21/2002 10:43a 1,394 SCS052.050 5% damped Sa for SCS052 07/13/2002 11:33a 125,076 SCS052.AT2 Acc time history for SCS052 1012112002 10:43a 363 SCS02In Input file for SPCTLR for SCS052 10/21/2002 10.43a 1,394 SCS142.050 5% damped Sa for SCS142 07/13/2002 11:33a 125,076 SCS142.AT2 Acc time history for SC142 10t2112002 10:43a 363SCS142.in InputfileforSPCTLRforSCS142 08/10t1989 10 08a 46,009 SPCTLR.EXE SPCTLR EXECUBALE FILE 10/21t2002 10:43a 1,394 SPV270.050 5% damped Sa for SPV270 07/13/2002 11:33a 19,308 SPV270.AT2 Acc time history for SPV270 10/21t2002 10-21a 363 SPV270.IN-Input file for SPCTLR for SPV270 10121/2002 10:43a 1,394 SPV360.050 5% damped Sa for SPC360 07/1312002 11 :33a 19,308 SPV360.AT2 Acc time history for SPC360 10/21/2002 10:21a 363 SPV360.IN Input file for SPCTLR for SPC360 10t212002 1 0.43a 1,394 SYL090.050 5% damped Sa for SYLO90 07/13/2002 11:34a 31,476 SYLO9O.AT2 Aco time history for SYLO90 10121/2002 10.20a 363 SYLO90.IN Input file for SPCTLR for SYLO90 10121t2002 10.20a 363 SYL260.IN 5% damped Sa for SYL360 10/212002 10:43a 1,394 SYL360.050 Acc time history for SYL360 07/1312002 11 :34a 31,476 SYL360.AT2 Input file for SPCTLR for SYL360 44 File(s) 866,620 bytes 2 Dir(s) 9,455,915,008 bytes free

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 91 of 196 Date: 11/06/02 Appendix A.

Spectral Shapes from Site Response Calculations The normalized spectral shapes from the SHAKE runs are listed in this appendix for each ground motion level, each profile, and each time history. Each table is for one velocity profile - time history pair.

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 92 of 196 Date: 11/06/02 Table A-i. Normalized spectral ACCs for median profile, earthquake 1 Period Input PGA (sec

.6 g ox L, 1.0 X 1.2 La 1A4 9 1.6 0.01 1.000 1.000 1.00 1.000 1.000 1.000 0.03 1.006 1.006 1.005 1.004 1.004 1.003 0.04 1.011 1.010 1.010 1.009 1.007 1.006 0.05 1.015 1.016 1.016 1.014 1.012 1.010 0.06 1.026 1.024 1.023 1.020 1.018 1.015 0.07 1.038 1.032 1.030 1.027 1.024 1.021 0.08 1.077 1.043 1.039 1.036 1.032 1.028 0.09 1.144 1.098 1.073 1.055 1.043 1.036 0.10 1.220 1.157 1.123 1.099 1.078 1.062 0.11 1.254 1.112 1.061 1.070 1.069 1.063 0.12 1.335 1.167 1.104 1.100 1.091 1.081 0.13 1.244 1.094 1.101 1.099 1.091 1.085 0.14 1.317 1.175 1.130 1.109 1.091 1.092 0.15 1.524 1.328 1.248 1.190 1.159 1.129 0.16 1.663 1.518 1.427 1.357 1.311 1.261 0.17 1.696 1.534 1.456 1.384 1.364 1.319 0.18 1.719 1.523 1.453 1.374 1.328 1.236 0.19 1.886 1.528 1.405 1.357 1.313 1.279 0.20 2.109 1.767 1.744 1.655 1.561 1.508 0.21 2.164 1.997 1.911 1.815 1.694 1.613 0.22 2.334 2.158 2.078 1.985 1.861 1.722 0.23 2.270 2.105 2.051 1.974 1.868 1.734 0.24 2.286 2.155 2.174 2.091 2.006 1.937 0.25 2A78 2.252 2.184 2.116 2.055 1.997 0.26 2.507 2.304 2.31 2.165 2.063 1.964 0.27 2.508 2.320 2.249 2.199 2.110 2.014 0.28 2.564 2.374 2.310 2.270 2.193 2.099 0.29 2.810 2.428 2373 2.351 2.284 2.190 0.30 2.966 2.740 2.592 2.531 2.464 2.397 0.31 3.092 2.871 2.744 2.696 2.641 2.582 0.32 2.936 2.739 2.647 2.629 2.608 2.574 0.33 2.602 2.475 2A64 2.489 2.474 2.405 0.34 2.510 2A10 2.415 2.462 2.468 2.401 0.35 2.510 2.466 2.525 2.556 2.528 2.470 0.36 2.517 2.88 2.560 2.597 2.607 2.545 0.37 2.567 2.556 2.610 2.700 2.736 2.668 0.38 2.583 2.574 2.809 2.896 2.913 2.836 0.39 2.566 2.699 3.001 3.108 3.187 3.229 0.40 2.566 2.756 3.071 3.343 3.539 3.586 0.41 2.516 2.877 3.227 3.520 3.735 3.797 0.42 2.393 2.782 3.152 3.459 3.692 3.773 0.43 2.164 2.566 2.942 3.259 3.514 3.613 0.44 2.002 2.337 2.720 3.052 3.331 3.453 0.45 1.963 2.117 2.512 2.861 3.166 3.311 0.46 1.948 1.988 2.289 2.652 2.979 3.146 0.47 1.987 1.983 2.054 2.401 2.744 2.930 0.48 2.018 1.956 2.042 2.266 2.571 2.716 0.49 1.990 1.877 1.975 2.191 2.488 2.625 0.50 1.911 1.785 1.857 2.055 2.328 2.453 0.51 I1.839 1.704 1.745 1919 2.164 2.272

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 93 of 196 Date: 11106102 0.52 1.823 1.672 1.700 1.840 2.065 2.162 0.53 1.849 1.681 1.718 1.812 2.029 2.119 0.54 1.882 1.714 1.761 1.843 2.010 2.096 0.55 1.915 1.773 1.814 1.899 1.992 2.074 0.56 1.957 1.851 1.887 1.977 2.070 2.060 0.57 1.986 1.931 1.967 2.070 2.178 2.125 0.58 2.137 1.968 2.012 2.131 2.259 2.217 0.60 2.272 2.136 2.016 2.014 2.172 2.156 0.62 2.370 2.273 2.114 2.070 2.095 2.013 0.64 2.439 2.383 2.233 2.186 2.199 2.103 0.66 2.404 2.366 2.259 2.291 2.331 2.250 0.68 2.119 2.158 2.195 2.252 2.315 2.248 0.70 1.968 2.086 2.156 2.226 2.295 2.228 0.72 1.955 2.110 2.189 2.257 2.319 2.238 0.74 1.810 1.973 2.034 2.086 2.161 2.188 0.76 1.715 1.785 1.888 2.000 2.151 2.183 0.78 1.688 1.760 1.864 1.996 2.157 2.165 0.80 1.654 1.727 1.855 1.993 2.162 2.189 0.82 1.617 1.691 1.840 1.983 2.160 2.204 0.84 1.578 1.653 1.821 1.967 2.152 2.213 0.86 1.538 1.618 1.796 1.947 2.138 2.215 0.88 1.496 1.586 1.768 1.921 2.118 2.209 0.90 1.455 1.552 1.736 1.891 2.092 2.197 0.92 1.415 1.519 1.703 1.859 2.063 2.179 0.94 1.377 1.487 1.670 1.825 2.032 2.158 0.96 1.343 1.456 1.636 1.792 2.000 2.136 0.98 1.321 1.428 1.604 1.758 1.968 2.112 1.00 1.303 1.399 1.572 1.724 1.936 2.086 1.05 1.264 1.325 1.482 1.629 1.838 2.003 1.10 1.253 1.237 1.372 1.507 1.708 1.880 1.15 1.271 1.247 1.315 1.399 1.552 1.729 1.20 1.309 1.279 1.325 1.383 1.512 1.651 1.25 1.286 1.282 1.339 1.408 1.532 1.652 1.30 1.400 1.417 1.500 1.597 1.759 1.911 1.35 1.484 1.513 1.596 1.670 1.794 1.899 1.40 1.539 1.545 1.557 1.598 1.736 1.853 1.45 1.503 1.542 1.585 1.609 1.689 1.760 1.50 1.491 1.549 1.607 1.646 1.739 1.794 1.55 1.495 1.563 1.630 1.687 1.790 1.851 1.60 1.471 1.551 1.625 1.701 1.812 1.880 1.65 1.445 1.561 1.635 1.675 1.793 1.867 1.70 1.388 1.523 1.614 1.626 1.749 1.829 1.75 1.296

.1.440 1.541 1.579 1.706 1.789 1.80 1.184 1.331 1.476 1.559 1.676 1.761 1.85 1.128 1.286 1.443 1.535 1.654 1.773 1.90 1.070 1.233 1.396 1.496 1.627 1.793 1.95 1.022 1.168 1.333 1.450 1.630 1.800 2.00 0.960 1.102 1.264 1.416 1.615 1.785 2.05 0.894 1.036 1.220 1.382 1.578 1.747 2.10 0.859 0.997 1.176 1.334 1.526 1.692 2.15 0.819 0.952 1.125 1.279 1.466 1.629 2.20 0.778 0.906 1.073 1.222 1.404 1.565 2.25 0.737 0.861 1.022 1.167 1.345 1.504 2.30 0.699 0.819 0.974 1.117 1.291 1.448 2.35 0.663 0.779 0.931 1.070 1.241 1.395 2.40 0.629 0.742 0.891 1.027 1.194 1.345

Calc Number: GEO.HBEP.02.06 Rev Number: 0 Sheet Number: 94 of 196 Date: 11/06/02 2.50 0.565 0.674 -0.814 0.944 1.102 1.245 2.60 0.505 0.609 0.739 0.860 1.008 1.142 2.70 0.456 0.546 0.666 0.778 0.914 1.040 2.80 0.432 0.493 0.597 0.700 0.827 0.947 2.90 0.410 0.469 0.551 0.632 0.749 0.867 3.00 0.393 0.450 0.529 0.608 0.710 0.809 3.10 0.377 0.433 0.511 0.588 0.688 0.786 3.20 0.363 0.418 0.494 0.570 0.669 0.807 3.30 0.350 0.404 0.478 0.553 0.651 0.758 3.40 0.335 0.388 0.462 0.535 0.632 0.727 3.50 0.320 0.372 0.443 0.515 0.610 0.704 3.60 0.303 0.353 0.422 0.493 0.585 0.678 3.70 0.284 0.333 0.400 0.468 0.558 0.649 3.80 0.265 0.311 0.375 0.441 0.528 0.619 3.90 0.244 0.288 0.349 0.412 0.498 0.587 4.00 0.223 0.265 0.323 0.385 0.469 0.554 4.10 0.209 0.241 0.298 0.358 0.437 0.518 4.20 0.196 0.224 0.274 0.331 OA05 0.481 4.30 0.181 0.209 0.251 0.304 0.373 0.443 4.40 0.165 0.192 0.229 0.278 0.341 0.406 4.50 0.162 0.187 0.225 0.266 0.324 0.385 4.60 0.157 0.181 0.218 0.258 0.313 0.372 4.70 0.146 0.168 0.203 0.240 0.291 0.346 4.80 0.130 0.150 0.181 0.214 0.260 0.309 4.90 0.130 0.149 0.178 0.209 0.253 0.298 5.00 0.128 0.146 0.175 0.207 0.249 0.295 5.10 0.125 0.143 0.170 0.201 0.242 0.287 5.20 0.120 0.138 0.165 0.194 0.234 0.277 5.40 0.110 0.126 0.151 0.178 0.215 0.254 5.60 0.100 0.112 0.134 0.159 0.192 0.227 5.80 0.093 0.105 0.124 0.145 0.176 0.208 6.00 0.087 0.099 0.117 0.137 0.165 0.194 6.20 0.082 0.093 0.110 0.129 0.155 0.183 6.40 0.076 0.088 0.104 0.121 0.146 0.172 6.60 0.076 0.087 0.103 0.121 0.145 0.170 6.80 0.076 0.086 0.103 0.120 0.144 0.169 7.00 0.072 0.083 0.098 0.115 0.138 0.162 7.20 0.068 0.078 0.092 0.107 0.128 0.150 7.40 0.067 0.076 0.090 0.105 0.125 0.146 7.60 0.063 0.072 0.086 0.100 0.120 0.140 7.80 0.059 0.068 0.080 0.094 0.112 0.131 8.00 0.054 0.062 0.074 0.086 0.103 0.120 8.50 0.043 0.049 0.058 0.067 0.078 0.091 9.00 0.037

.042 0.050 0.058 0.068 0.079 9.50 0.029 0.034 0.040 I

0.047 0.056 0.065 10.00 0.023 0.028 0.033 0.039 0.046 0.054

Calc Number GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 95 of 196 Date: 11106/02 Table A-2. Normalized spectral ACCs for median profile, earthquake 2 Period Invu PGA (se 1.6 0.0 0 1.013 1.2 1.4 1.6 0.01 1.000 1.000 1.048 1.000 1.000 1.000 0.03 1.005 1.003 1.003 1.003 1.002 1.002 0.04 1.008 1.006 1.006 1.005 1.005 1.004 0.05 1.016 1.011 1.080 1.00 1.054 1.007 0.06 1.028 1.018 1.026 1.024 1.012 1.010 0.07 1.017 1.018 1.020 1.017 1.015 1.014 0.08 1.612 1.12 1.007 1.016 1.017 1.017 0.09 1.130 1.32 1.029 08

.032 1.009 0.10 1.192 1.112 1.080 1.061 1.049 1.042 0.11 1.222 1.120 1.08 1.070 1.057 1.049 0.19 2.219 1.155 1.07 1.03 1.054 1.049 0.13 1.425 1.195 1.027 1.027 1.02 1.031 0.14 1.492 1.161 1.032 0.988 0.999 1.014 0.1 1.612 1.208 1.007 0.989 1.003 1.017 0.16 1.730 1.320 1.029 0.986 0.992 1.009 0.17 1.968 1.453 1.185 1.073 1.005 1.015 0.18 2.029 1.607 1.347 1.208 1.127 1.866 0.19 2.219 1.855 1.576 1.431 1.324 1.218 0.20 2.508 2.106 1.798 1.631 1.509 1.385 0.21 2.595 2.199 1.896 1.730 1.607 1.483 0.22 2.694 2.297 2.000 1.834 1.707 1.579 0.23 2.794 2.404 2.107 1.942 1.816 1.685 0.24 2.872 2.485 2.197 2.037 1.909 1.778 0.25 2.927 2.553 2.27 2.122 12.996

.866 0.26 2.969 2.609 2.343 2.194 2.072 1.94 0.27 3.004 2.652 2.403 2.262 2.142 2.01 0.2 3.024 2.689 2.453 2.318 2.204 2.081 0.29 3.013 2.694 2.780 2.360 2.249 2.132 0.30 2.961 2.669 2.44 2.376 2.275 2.164 0.31 2.994 2.626 2.471 2.379 2.285 2.182 0.32 2.983 2.596 2.464 2.384 2.298 2.200 0.33 3.083 2.592 2.479 2.405 2.324 2.231 0.34 3.321 2.781 2.62 2.607 2.643 2.273 0.43 3.245 2.739 2.549 2.483 2.404 2.317 0.36 2.881 2.658 2.579 2.518 2.442 2.35 0.37 2.792 2.775 2.597 2.544 2.472 2.392 0.38 - 2.770 2.660 2.608 2.561 2.492 2.417 0.39 2.735 2.64 2.608 2.568 2.506 2.437 0.40 2.687 2.619 2.599 2.569 2.310 2.447 0.41 2.627 2.580 2.620 2.607 2.504 2.447 0.42.

2.545 2.525 2.622 2.637 2.546 2.45 0.50 2.442 2.446 2.570 2.606 2.626 2.440 0.44 2.310 2.341 2.532 2.721 2.732 2.656 OA5 2.149 2.302 2.656 2.899 2.930 2.864 0.46 2.145 2.191 2592 2.870 2.924 2.876 0.47 2.074 2.085 2.331 2.713 2.832 2.827 0.48 2.14 2.071 _2.251 2.535 2.666 2.674 0.49 2.299 2.053 2.250 2523 2.667 2.76 0.50 2.323 2.095

.223 2.490I 2.668 2.74 0.1 I 2.302 12.090 2.209 12.460-2.623 2.696 0.52 2.274 2.076 2.189 2.425 2.581 2.649 0.53 2.337 2.065 2.174 2.404 2.555 2.623

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 96 of 196 Date: 11/06/02 0.54 2.380 2.075 2.153 2.379 2.530 2.600 0.55 2.379 2.094 2.126 2.329 2.477 2.550 0.56 2.318 2.065 2.101 2.297 2.410 2.450 0.57 2.201 1.988 2.030 2.214 2.321 2.318 0.58 2.211 1.914 1.953 2.100 2.206 2.287 0.60 2.400 2.107 2.051 2.192 2.316 2.417 0.62 2.451 2.217 2.176 2.266 2.317 2.303 0.64 2.417 2.204 2.171 2.260 2.303 2.283 0.66 2.395 2.307 2.327 2.445 2.485 2.410 0.68 2.405 2.321 2.338 2.447 2.481 2.409 0.70 2.224 2.156 2.190 2.299 2.345 2.307 0.72 2.064 2.019 2.094 2.212 2.302 2.282 0.74 2.110 2.091 2.193 2.329 2.425 2.404 0.76 2.118 2.109 2.213 2.349 2.462 2.445 0.78 2.026 2.015 2.117 2.277 2.397 2.398 0.80 2.009 2.016 2.130 2.306 2.436 2.446 0.82 1.937 1.961 2.080 2.263 2.394 2.406 0.84 1.731 1.764 1.887 2.071 2.220 2.347 0.86 1.798 1.811 1.968 2.161 2.317 2.445 0.88 1.756 1.760 1.901 2.084 2.229 2.340 0.90

'1.650 1.641 1.758 1.917 2.043 2.141 0.92 1.638 1.619 1.725 1.875 1.996 2.100 0.94 1.706 1.687 1.794 1.950 2.081 2.203 0.96 1.713 1.698 1.805 1.961 2.095 2.224 0.98 1.624 1.611 1.709 1.853 1.980 2.102 1.00 1.529 1.512 1.598 1.728 1.842 1.953 1.05 1.502 1.478 1.552 1.668 1.774 1.888 1.10 1.447 1.372 1.417 1.509 1.608 1.745 1.15 1.572 1.472 1.495 1.567 1.651 1.780 1.20 1.763 1.670 1.653 1.660 1.637 1.633 1.25 1.794 1.724 1.726 1.747 1.733 1.717 1.30 1.734 1.670 1.686 1.716 1.710 1.694 1.35 1.751 1.664 1.642 1.651 1.649 1.633 1.40 1.746 1.674 1.658 1.663 1.630 1.587 1.45 1.718 1.658 1.647 1.654 1.621 1.573 1.50 1.655 1.607 1.602 1.609 1.576 1.523 1.55 1.574 1.611 1.652 1.685 1.666 1.621 1.60 1.575 1.611 1.653 1.688 1.668 1.620 1.65 1.590 1.631 1.673 1.705 1.682 1.628 1.70 1.503 1.544 1.581 1.609 1.650 1.650 1.75 1.333 1.378 1.455 1.540 1.589 1.595 1.80 1.296 1.399 1.500 1.597 1.654 1.659 1.85 1.368 1 A85 1.595 1.695 1.748 1.739 1.90 1.324 1.440 1.543 1.632 1.671 1.691 1.95 1.202 1.309 1.403 1.499 1.587 1.648 2.00 1.087 1.213 1.335 1.467 1.610 1.731 2.05 1.045 1.192 1.338 1.484 1.621 1.729 2.10 0.942 1.072 1.200 1.326 1.435 1.512 2.15 0.904 0.990 1.095 1.214 1.344 1.488 2.20 0.885 0.970 1.074 1.191 1.321 1.463 2.25 0.854 0.940 1.041 1.156 1.283 1A23 2.30 0.813 0.899 0.997 1.108 1.231 1.380 2.35 0.764 0.848 0.943 1.049 1.168 1.300 2.40 0.707 0.789 0.880 0.981 1.095 1.232 2.50 0.652 0.726 0.814 0.915 1.035 1.181 2.60 0.603 0.674 0.756 0.851 0.965 1.104

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 97 of 196 Date: 1 1/06/02 2.70 0.542 0.609 1 0.685 0.773 1 0.879 1.011 2.80 0.477 0.537 0.607 0.688 0.785 0.907 2.90 0.440 0.487 0.545 0.614 0.699 0.803 3.00 OA12 0.456 0.510 0.575 0.654 0.753 3.10 0.403 0.433 0.474 0.534 0.608 0.703 3.20 0.373 0.405 0.445 0.494 0.563 0.653 3.30 0.327 0.359 0.403 0.455 0.522 0.611 3.40 0.323 0.354 0.390 0.434 0.490 0.574 3.50 0.303 0.335 0.373 0.417 0.473 0.546 3.60 0.274 0.297 0.331 0.373 0.429 0.503 3.70 0.266 0.284 0.309 0.347 0.399 0.468 3.80 0.273 0.293 0.319 0.353 0.395 0.448 3.90 0.280 0.302 0.331 0.367 0.413 0.471 4.00 0.272 0.296 0.326 0.363 0.411 0.472 4.10 0.245 0.268 0.297 0.333 0.379 0.438 4.20 0.209 0.230 0.255 0.287 0.329 0.382 4.30 0.203 0.218 0.240 0.267 0.301 0.345 4.40 0.192 0.206 0.226 0.252 0.286 0.330 4.50 0.177 0.188 0.204 0.228 0.259 0.300 4.60 0.170 0.180 0.195 0.214 0.238 0.277 4.70 0.185 0.197 0.213 0.233 0.257 0.287 4.80 0.190 0.204 0.222 0.245 0.271 0.305 4.90 0.184 0.199 0.218 0.241 0.270 0.305 5.00 0.170 0.185 0.204 0.226 0.255 0.291 5.10 0.153 0.168 0.186 0.207-0.234 0.269 5.20 0.140 0.154 0.171 0.191 0.216 0.249 5.40 0.125 0.137 0.153 0.172 0.196 0.227 5.60 0.112 0.119 0.133 0.150 0.173 0.202 5.80 0.118 0.123 0.134 0.147 0.164 0.185 6.00 0.121 0.127 0.138 0.152 0.170 0.193 6.20 0.109 0.112 0.121 0.135 0.152 0.173 6.40 0.108 0.113 0.119 0.127 0.138 0.151 6.60 0.093 0.098 0.104 0.112 0.123 0.139 6.80 0.082 0.087 0.094 0.103 0.113 0.128 7.00 0.080 0.085 0.092 0.101 0.113 0.127 7.20 0.079 0.083 0.089 0.097 0.107 0.119 7.40 0.076 0.080 0.086 0.094 0.104 0.116 7.60 0.072 0.075 0.080 0.087 0.095 0.104 7.80 0.068 0.072 0.077 0.083 0.091 0.100 8.00 0.063 0.067 0.071 0.078 0.085 0.094 8.50 0.049 0.052 0.056 0.061 0.068 0.076 9.00 0.050 0.053 0.057 0.063 0.071 0.080 9.50 0.051 0.054 0.058 0.063 0.069 0.078

_0.00 _

0_053 0Q046 I 0.049 0.060 -1 0.068 10.00 0.053 0.046 0.049 0.054 0.060

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 98 of 196 Date: 11/06/02 Table A-3. Normalized spectral ACCs for median profile, earthquake 3 Period In ut PGA (sec) 0.6g 0.8i 1.0 1.2 1A g 1.6 0.01 1.000 1.000 1.000 1.000 1.000 1.000 0.03 1.006 1.002 1.001 1.002 1.002 1.002 0.04 1.012 1.004 1.003 1.003 1.003 1.004 0.05 1.019 1.009 1.004 1.005 1.006 1.006 0.06 1.031 1.015 _1.006 1.008 1.008 1.008 0.07 1.044 1.021 1.009 1.011 1.011 1.011 0.08 1.058 1.021 1.006 1.012 1.014 1.014 0.09 1.091 1.049 1.020 1.021 1.021 1.020 0.10 1.226 1.121 1.015 1.013 1.014 1.015 0.11 1.224 1.193 1.012 1.017 1.019 1.020 0.12 1.354 1.276 1.046 0.994 0.998 1.004 0.13 1.400 1.346 1.121 1.051 1.034 1.032 0.14 1.539 1.356 1.091 1.063 1.055 1.055 0.15 1.594 1.425 1.064 1.018 1.018 1.031 0.16 1.816 1.430 1.178 1.088 I1.063 1.053 0.17 1.903 1.620 1.352 1.227 1.181 1.160 0.18 1.882 1.831 1.527 1.372 1.308 1.280 0.19 2.038 1.933 1.513 1.383 1.326 1.311 0.20 2.091 1.985 1.550 1.395 1.345 1.366 0.21 2.184 2.058 1.617 1.466 1.415 1.434 0.22 2.279 2.066 1.649 1.504 1.452 1.469 0.23 2.388 2.113 1.673 1.565 1.531 1.513 0.24 2.483 2.207 1.823 1.700 1.655 1.633 0.25 2.562 2.349 1.862 1.741 1.691 1.669 0.26 2.681 2.241 1.833 1.716 1.661 1.641 0.27 2.808 2.425 1.724 1.524 1.477 1.517 0.28 3.249 2.616 1.808 1.634 1.546 1.542 0.29 3.244 2.674 1.893 1.705 1.608 1.595 0.30 3.324 2.698 1.877 1.694 1.608 1.576 0.31 3.416 2.796 2.031 1.808 1.714 1.694 0.32 3.238 2.831 2.066 1.847 1.757 1.745 0.33 3.196 2.851 2.056 1.809 1.696 1.729 0.34 3.341 3.116 2.280 2.025 1.941 1.976 0.35 3.506 3.170 2.401 2.184 2.103 2.144 0.36 3.189 3.235 2.482 2.282 2.205 2.250 0.37 3.118 3.213 2.562 2.397 2.322 2.397 0.38 3.092 3.387 2.726 2.536 2.482 2.574 0.39 3.080 3.426 2.642 2.481 2.442 2.542 0.40 2.865 3.250 2.795 2.562 2.487 2.580 0.41 2.619 3.107 2.804 2.707 2.664 2.711 0.42 2.499 2.976 2.975 2.896 2.864 2.927 OA3 2.440 2.930 3.024 2.964 2.942 3.016 0.44 2.312 2.682 2.790 2.742 2.725 2.793 0.45 2.047 2.371 2.355 2.332 2.373 2.477 0.46 2.107 2.254 2.374 2.431 2A33 2.482 0.47 2.062 2.260 2.373 2.426 2.500 2.601 0.48 2.017 2.185 2.291 2A30 2.524 2.638 0.49 2.073 2.187 2.289 2.347 2.433 2.558 0.50 2.059 2.210 2.328 2.410 2.398 2.364 0.51 2.117 2.142 2.274 2.376 2.379 2.353 0.52 2.113 1.990 2.086 2.193 2.205 2.197 0.53 2.219 2.116 1.996 1.997 2.030 2.053

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 99 of 196 Date: 11/06/02 0.54 2.294 2.235 1 2.65 2.186 2.157 2.113 0.55 2.380 2.276 2.216 2.251 2.230 2.190 0.56 2.522 2.416 2.173 2.217 2.200 2.165 0.57 2.555 2.467 2.215 2.168 2.136 2.085 0.58 2.519 2.441 2.211 2.167 2.139 2.100 0.60 2.359 2.293 2.096 2.062 2.042 -2.024 0.62 2.308 2.217 1.962 1.962 1.962 1.901 0.64 2.476 2.426 2.214 2.172 2.061 1.944 0.66 2.417 2.432 2.294 2.273 2.196 2.026 0.68 2.207 2.254 2.132 2.145 2.113 1.991 0.70 2.079 2.296 2.251 2.214 2.079 1.894 0.72 2.223 2.446 2.380 2.345 2.207 2.010 0.74 2.164 2.362 2.291 2.269 2.147 1.959 0.76 2.097 2.291 2.219 2.204 2.090 1.985 0.78 1.987 2.176 2.102 2.161 2.213 2.130 0.80 1.867 2.090 2.114 2.245 2.297 2.211 0.82 1.837 2.078 2.113 2.250 2.307 2.227 0.84 1.762 2.018 2.067 2.211 2.278 2.207 0.86 1.652 1.919 1.983 2.134 2.210 2.150 0.88 1.547 1.768 1.845 2.000 2.083 2.038 0.90 1.481 1.588 1.672 1.826 1.916 1.891 0.92 1.406 1.472 1.514 1.665 1.763 1.760 0.94 1.481 1.532 1.473 1.560 1.723 1.876 0.96 1.583 1.650 1.591 1.683 1.841 1.986 0.98 1.649 1.728 1.666 1.762 1.916 2.056 1.00 1.681 1.771 1.703 1.798 1.949 2.086 1.05 1.585 1.672 1.596 1.681 1.818 1.948 1.10 1.683 1.706 1.611 1.647 1.709 1.791 1.15 1.705 1.790 1.703 1.752 1.826 1.915 1.20 1.650 1.780 1.704 1.764 I.846 1.936 1.25 1.596 1.727 1.660 1.725 1.809 1.898 1.30 1.558 1.689 1.624 1.692 1.778 1.867 1.35 1.621 1.633 1.573 1.643 1.731 1.822 1.40 1.624 1.596 1.512 1.584 1.673 1.763 1.45 1.669 1.752 1.585 1.568 1.655 1.744 1.50 1.530 1.619 1.515 1.583 1.671 1.762 1.55 1.439 1.572 1.502 1.569 1.660 1.756 1.60 1.460 1.600 1.478 1.503 1.598 1.700 1.65 1.514 1.664 1.545 1.514 1.523 1.628 1.70 1.472 1.630 1.525 1.505 1.501 1.596 1.75 1.436 1.607 1.513 1.521 1.540 I 1.621 1.80 1.409 1.590 1.514 1.543 1.566 1.673 1.85 1.316 1.486 1.416 1.499 1.603 1.710 1.90 1.260 1.441 1.409 1.497 1.598 1.705 1.95 1.221 1.399 1.368 1.452 1.570 1.676 2.00 1.151 1.319 1.293 1.423 1.554 1.666 2.05 1.094 1.297 1.301 1.401 1.515 1.621 2.10 1.027 1.221 1.242 1.373 1.490 1.570 2.15 0.929 1.108 1.123 1.232 1.364 1.529 2.20 0.855 1.010 1.014 1.144 1.339 1.548 2.25 0.805 0.956 0.966 1.118 1.340 1.546 2.30 0.757 0.905 0.922 1.102 1.315 1.516 2.35 0.710 0.856 0.892 1.064 1.266 1.464 2.40 0.664 0.808 0.847 1.008 1.200 1.399 2.50 0.582 0.712 0.739 0.868 1.050 1.245 2.60 0.608 0.727 0.753 0.881 1.063 1.283

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 100 of 196 Date: 1 1/06/02 2.70 0.540 0.657 0.691 0.820 1.002 1.223 2.80 0.485 0.586 0.613 0.727 0.892 1.096 2.90 0.420 0.496 0.517 0.620 0.763 0.931 3.00 0.409 0.474 0.494 0.590 0.727 0.885 3.10 0.398 0.457 0.467 0.556 0.686 0.840 3.20 0.377 0.433 0.439 0.517 0.638 0.785 3.30 0.349 0.401 0.409 0.476 0.584 0.719 3.40 0.356 0.413 0.422 0.492 0.592 0.714 3.50 0.352 0.409 0.418 0.488 0.590 0.714 3.60 0.308 0.360 0.370 0.433 0.525 0.640 3.70 0.265 0.314 0.323 0.373 0.442 0.540 3.80 0.245 0.291 0.299 0.346 0.412 0.493 3.90 0.238 0.284 0.292 0.339 0.406 0.488 4.00 0.223 0.266 0276 0.323 0.390 0.475 4.10 0.215 0.245 0.243 0.281 0.345 0.426 4.20 0.187 0.215 0.218 0.259 0.316 0.381 4.30 0.176 0.208 0.216 0.256 0.312 0.378 4.40 0.181 0.203 0.211 0.250 0.305 0.371 4.50 0.184 0.203 0.203 0.241 0.294 0.358 4.60 0.185 0.212 0.210 0.234 0.279 0.343 4.70 0.180 0.207 0.207 0.231 0.268 0.328 4.80 0.175 0.198 0.195 0.212 0.250 0.310 4.90 0.170 0.193 0.190 0.208 0.233 0.289 5.00 0.164 0.186 0.184 0.202 0.227 0.266 5.10 0.156 0.178 0.176 0.194 0.218 0.248 5.20 0.150 0.173 0.173 0.194 0.224 0.264 5.40 0.146 0.170 0.171 0.194 0.227 0.270 5.60 0.114 0.131 0.127 0.145 0.173 0.207 5.80 0.110 0.124 0.122 0.135 0.153 0.174 6.00 0.105 0.119 0.118 0.131 0.150 0.173 6.20 0.099 0.113 0.113 0.127 0.146 0.171 6.40 0.094 0.108 0.108 0.123 0.145 0.171 6.60 0.092 0.104 0.105 0.119 0.141 0.168 6.80 0.088 0.099 0.097 0.109 0.130 0.155 7.00 0.084 0.096 0.096 0.107 0.123 0.143 7.20 0.081 0.094 0.094 0.106 0.123 0.145 7.40 0.075 0082 0.079 0.090 0.106 0.126 7.60 0.071 0.079 0.076 0.082 0.097 0.116 7.80 0.064 0.072 0.069 0.075 0.087 0.105 8.00 0.055 0.061 0.059 0.067 0.080 0.096 8.50 0.055 0.061 0.060 0.066 0.075 0.085 9.00 0.050 0.057 0.056 0.062 0.071 0.082 9.50 0.046 0.051 0.050 0.055 0.063 0.073 10.00 0.041 0.047 0.046 0.05 1 0.058 0.068

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number 101 of 196 Date: 11/06/02 Table A-4. Normalized spectral ACCs for lower bound profile, earthquake 1 Period Input PGA (see) 0.6 0.8 1.0 1.2 14 1.6 0.01 1.000 1.000 1.000 l.000 1.000 1.000 0.03 1.006 1.006 1.003 1.002 1.001 1.001 0.04 1.011 1.011 1.006 1.004 1.003 1.003 0.05 1.018 1.018 1.010 1.006 1.004 1.004 0.06 1.027 1.026 1.015 1 1.009 1.0071 1.006 0.07 1.039 1.037 1.021 1.013 1.009 1.009 0.08 1.073 1.059 1.028 1.017 1.012 1.011 0.09 1.084 1.073 1.035 1.027 1.015 1.015 0.10 1.102 1.092 1.065 1.034 1.017 1.018 0.11 1.168 1.141 1.070 1.053 1.018 1.020 0.12 1.222 1.185 1.086 1.068 1.022 1.023 0.13 1.178 1.160 1.104 1.086 1.035 1.019 0.14 1.285 1.245 1.165 1.126 1.050 1.029 0.15 1.366 1.377 1.310 1.231 1.078 1.047 0.16 1.386 1.428 1.366 1.283 1.126 1.064 0.17 1.510 1.446 1.354 I 1.290 1.160 1.091 0.18 1.550 1.499 1.333 1.312 1.207 1.052 0.19 1.496 1.454 1.388 1.318 1.165 1.103 0.20 1.816 1.848 1.756 1.619 1.384 1.133 0.21 2.083 2.032 1.886 1.739 1.498 1.204 0.22 2.285 2.231 1.977 1.734 1.466 1.323 0.23 2.262 2.227 1.986 1.747 1.611 1.439 0.24 2.320 2.295 2.121 1.983 1.818 1.605 0.25 2.367 2.399 2.248 2.088 1.861 1.623 0.26 2.432 2.513 2.397 2.275 2.025 1.685 0.27 2.450 2.511 2.419 2.338 2.111 1.781 0.28 2.519 2.593 2.486 2.355 2.136 1.842 0.29 2.606 2.691 2.591 2.467 2.245 1.943 0.30 2.618 2.709 2.627 2.515 2.303 2.007 0.31 2.724 2.914 2.797 2.599 2.386 2.086 0.32 2.729 2.942 2.845 2.692 2.479 2.177 0.33 2.738 2.879 2.833 2.741 2.538 2.241 0.34 2.721 2.873 2.841 2.758 2.569 2.283 0.35 2.737 2.898 2.871 2.795 2.616 2.335 0.36 2.844 3.005 12.980 2.905 2.721 2.429 0.37 2.956 3.118 3.103 3.027 2.837 2.532 0.38 3.068 3.203 3.147 3.079 2.892 2.590 0.39 3.349 3.644 3.546 3.217 2.941 2.644 0.40 3.715 4.052 3.967 3.612 3.094 2.681 OA1 3.917 4.298 4.242 3.894 3.334 2.886 0.42 3.869 4.287 4.278 3.972 3.414 2.981 0.43 3.687 4.134 4.173 3.928 3.398 3.006 0.44 3.515 3.989 4.069 3.880 3.440 3.061 0.45 3.367 3.870 3.989 3.850 3.547 3.169 0.46 3.198 3.728 3.876 3.800 3.667 3.287 0.47 2.974 3.519 3.732 3.893 3.761 3.382 0.48 2.900 3.469 3.741 3.909 3.779 3.412 0.49 2.807 3.351 3.614 3.776 3.659 3.326 0.50 2.619 3.114 3.356 3.513 3A25 3.148 0.51 2.419 2.860 3.090 3.255 3.212 2.998 0.52 2295 2.705 2.942 3.134 3.144 2.975 0.53 2.245 2.651 2.910 3.140 3.192 3.049

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 102 of 196 Date: 11/06/02 0.54 2.222 2.631 2.913 3.177 3.263 3.137 0.55 2.202 2.612 2.915 3.213 3.331 3.226 0.56 2.191 2.606 2.934 3.269 3.425 3.340 0.57 2.216 2.594 2.952 3.330 3.525 3.455 0.58 2.311 2.524 2.905 3.319 3.544 3.570 0.60 2.240 2.463 2.598 2.898 3.285 3.504 0.62 2.059 2.180 2.294 2.565 2.961 3.173 0.64 2.156 2.266 2.372 2.619 2.896 3.120 0.66 2.161 2.235 2.338 2.590 2.927 3.165 0.68 2.172 2.242 2.367 2.530 2.805 3.021 0.70 2.177 2.277 2A04 2.543 2.706 2.894 0.72 2.236 2.300 2.431 2.572 2.692 2.868 0.74 2.135 2.305 2.439 2.582 2.632 2.685 0.76 2.026 2.290 2.427 2.572 2.624 2.588 0.78 2.018 2.259 2.400 2.546 2.599 2.565 0.80 2.001 2.258 2.364 2.511 2.564 2.531 0.82 1.979 2.261 2.330 2.471 2.524 2.492 0.84 1.953 2.259 2.348 2.428 2.481 2.450 0.86 1.923 2.253 2.363 2.410 2.436 2A05 0.88 1.890 2.240 2.371 2.432 2.388 2.357 0.90 1.854 2.222 2.372 2.449 2.383 2.309 0.92 1.816 2.200 2.369 2.462 2.402 2.270 0.94 1.778 2.176 2.362 2.471 2.420 2.280 0.96 1.741 2.150 2.353 2.478 2.436 2.292 0.98 1.705 2.124 2.358 2.513 2.459 2.304 1.00 1.668 2.096 2.366 2.542 2.508 2.329 1.05 1.565 2.006 2.330 2.553 2.573 I 2.409 1.10 1.435 1.874 2.210 2.581 2.709 2.588 1.15 1.281 1.703 2.100 2.505 2.678 2.600 1.20 1.227 1.566 1.891 2.289 2.549 2.548 1.25 1.215 1.497 1.734 2.081 2.336 2.480 1.30 1.417 1.779 2.064 2.394 2.674 2.783 1.35 1.443 1.745 1.979 2.302 2.549 2.629 1.40 1.390 1.698 1.923 2.157 2.312 2.326 1.45 1.364 1.596 1.816 2.041 2.183 2.186 1.50 1.410 1.625 1.788 2.010 2.141 2.130 1.55 IA52 1.682 1.822 2.046 2.174 2.152 1.60 1.468 1.710 1.859 2.090 2.219 2.190 1.65 1.446 1.695 1.870 2.107 2.239 2.207 1.70 1.403 1.656 1.861 2.101 2.235 2.202 1.75 1.361 1.616 1.852 2.094 2.228 2.196 1.80 1.332 1.604 1.858 2.102 2.237 2.205 1.85 1.311 1.622 1.879 2.125 2.262 2.231 1.90 1.287 1.641 1.900 2.149 2.289 2.260 1.95 1.272 1.646 1.907 2.157 2.300 2.275 2.00 1.258 1.630 1.889 2.140 2.285 2.264 2.05 1.227 1.591 1.849 2.099 2.244 2.228 2.10 1.182 1.538 1.793 2.040 2.185 2.171 2.15 1.131 1.478 1.731 1.975 2.117 2.105 2.20 1.080 1.419 1.669 1.909 2.049 2.037 2.25 1.032 1.364 1.611 1.847 1.984 1.973 2.30 0.990 1.315 1.557 1.788 1.923 1.912 2.35 0.951 1.269 1.506 1.733 1.865 1.856 2.40 0.915 1.225 IA57 1.680 1.810 1.802 2.50 0.845 1.137 1.357 1.571 1.699 1.696 2.60 0.773 1.044 1.252 1.459 1.588 1.593

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 103 of 196 Date: 11/06/02 2.70 0.701 0.951 1.149 1.354 1.491 1.508 2.80 0.632 0.864 1.059 1.317 1.507 1.536 2.90 0.569 0.789 0.996 1.300 1.543 1.614 3.00 0.540 0.734 0.978 1.302 1.557 1.649 3.10 0.522 0.717 0.980 1.317 1.617 1.763 3.20 0.507 0.741 1.008 1.346 1.645 1.792 3.30 0.492 0.696 0.949 1.265 1.546 1.688 3.40 0.476 0.659 0.829 1.106 1.357 1.487 3.50 0.459 0.637 0.798 1.024 1.230 1.331 3.60 0.439 0.613 0.772 0.992 1.198 1.303 3.70 0.417 0.587 0.745 0.952 1.157 1.264 3.80 0.394 0.560 0.716 0.905 1.106 1.216 3.90 0.369 0.532 0.684 0.854 1.052 1.163 4.00 0.346 0.503 0.647 0.809 0.996 1.105 4.10 0.324 0.471 0.607 0.760 0.936 1.040 4.20 0.300 0.438 0.565 0.708 0.871 0.970 4.30 0.276 0.404 0.523 0.656 0.804 0.896 4.40 0.253 0.371 0.480 0.604 0.736 0.822 4.50 0.237 0.346 0.456 0.594 0.719 0.795 4.60 0.229 0.334 0.440 0.573 0.693 0.767 4.70 0.213 0.310 0.408 0.529 0.638 0.705 4.80 0.190 0.277 0.364 0.472 0.569 0.626 4.90 0.185 0.267 0.350 0.452 0.540 0.586 5.00 0.183 0.264 0.346 0.446 0.535 0.583 5.10 0.177 0.257 0.336 0.434 0.522 0.570 5.20 0.171 0.247 0.324 0.419 0.504 0.551 5.40 0.158 0.227 0.296 0.383 0.461 0.506 5.60 0.141 0.203 0.265 0.342 0.413 0.454 5.80 0.128 0.186 0.242 0.309 0.363 0.401 6.00 0.120 0.173 0.226 0.290 0.342 0.366 6.20 0.113 0.163 0.212 0.272 0.323 0.347 6.40 0.107 0.153 0.199 0.256 0.304 0.327 6.60 0.106 0.151 0.195 0.247 0.291 0.314 6.80 0.106 0.150 0.194 0.246 0.290 0.313 7.00 0.101 0.144 0.185 0.235 0.277 0.300 7.20 0.094 0.133 0.171 0.217 0.256 0.277 7AO 0.092 0.130 0.166 0.209 0.243 0.260 7.60 0.088 0.124 0.159 0.200 0.234 0.250 7.80 0.082 0.116 0.149 0.188 0.220 0.236 8.00 0.076 0.107 0.138 0.174 0.203 0.218 8.50 0.058 0.081 0.104 0.132 0.155 0.166 9.00 0.050 0.070 0.088 0.110 0.130 0.141 9.50 0.041 0.058 0.073 0.090 0.106 0.116 10.00 0.034 0.048 0.061 0.077 0.088 0.092

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 104 of 196 Date: 11/06/02 Table A-5. Normalized spectral ACCs for lower bound profile, earthquake 2 Period Input PGA (see)

.6g 0.8 1.0g L12 iiA 11.6!

0.01 1.000 1.000 1.000 1.000 1.000 1.000 0.03 1.003 1.003 1.002 1.002 1.002 1.001 0.04 1.006 1.005 1.004 1.004 1.003 1.003 0.05 1.010 1.008 1.007 1.006 1.005 1.004 0.06 1.017 1.013 1.011 1.009 1.007 1.006 0.07 1.018 1.017 1.015 1.013 1.009 1.009 0.08 1.010 1.017 1.017 1.017 1.012 1.012 0.09 1.052 1.036 1.028 1.024 1.015 1.015 0.10 1.090 1.060 1.043 1.033 1.022 1.020 0.11 1.101 1.068 1.051 1.039 1.027 1.025 0.12 1.096 1.066 1.050 1.039 1.034 1.032 0.13 1.050 1.038 1.031 1.025 1.038 1.037 0.14 1.016 0.994 1.009 1.019 1.024 1.029 0.15 1.005 0.991 1.009 1.022 1.032 1.036 0.16 1.056 0.991 1.002 1.021 1.013 1.024 0.17 1.232 1.060 0.998 1.056 1.101 1.078 0.18 1.397 1.186 1.048 1.091 1.137 1.113 0.19 1.601 1.415 1.255 1.179 1.181 1.149 0.20 1.823 1.616 1.433 1.334 1.249 1.158 0.21 1.924 1.722 1.540 1.435 1.340 1.235 0.22 2.038 1.837 1.652 1.537 1.430 1.311 0.23 2.156 1.955 1.766 1.642 1.523 1.392 0.24 2.256 2.060 1.872 1.741 1.612 IA68 0.25 2.344 2.153 1.966 1.832 1.694 1.542 0.26 2.417 2.236 2.055 1.917 1.772 1.609 0.27 2.486 2.313 2.134 1.995 1.845 1.675 0.28 2.546 2.381 2.210 2.070 1.912 1.736 0.29 2.585 2.435 2.269 2.128 1.969 1.787 0.30 2.601 2.462 2.306 2.169 2.006 1.822 0.31 2.597 2.473 2.326 2.193 2.031 1.845 0.32 2.598 2.482 2.348 2.218 2.055 1.869 0.33 2.616 2.507 2.382 2.255 2.088 1.900 0.34 2.650 2.547 2.428 2.303 2.134 1.941 0.35 2.688 2.593 2.481 2.356 2.184 1.985 0.36 2.723 2.634 2.532 2.407 2.230 2.028 0.37 2.749 2.670 2.574 2.452 2.272 2.064 0.38 2.765 2.696 2.612 2.489 2.306 2.097 0.39 2.777 2.719 2.641 2.520 2.335 2.122 0.40 2.854 2.731 2.664 2.545 2.356 2.140 0.41 2.969 2.796 2.676 2.558 2.368 2.150 0.42 3.019 2.863 2.736 2.558 2.365 2.147 0.43 2.991 2.855 2.737 2.566 2.344 2.127 0.44 3.208 3.083 2.943 2.734 2.458 2.275 0.45 3.452 3.354 3.216 3.069 2.843 2.632 0.46 3.448 3.390 3.393 3.303 3.080 2.858 0.47 3.225 3.298 3.335 3.278 3.136 2.997 0.48 2.959 3.114 3.220 3.361 3.355 3.208 OA9 2.954 3.164 3.278 3.421 3.420 3.276 0.50 2.769 3.064 3.224 3.369 3.379 3.246 0.51 2.700 2.976 3.129 3.279 3.303 3.184 0.52 2.635 2.900 3.050 3.209 3.247 3.139 0.53 2.591 2.854 3.008 3.176 3.226 3.126

Calc Number. GEO.HBIP.02.06 Rev Number: 0 Sheet Number. 105 of 196 Date: 11/06/02 0.54 2.552 2.818 -2.979 3.155 3.211 3.115 0.55 2A88 2.760 2.923 3.100 3.159 3.065 0.S6 2.377 2.648 2.809 2.981 3.036 2.986 0.57 2.255 2.483 2.634 2.789 2.915 2.951 0.58 2.125 2.317 2.501 2.726 2.841 2.812 0.60 2.159 2.474 2.715 3.002 3.164 3.152 0.62 2.152 2.248 2.514 2.822 2.999 2.998 0.64 2.132 2.210 2.315 2.547 2.738 2.797 0.66 2.265 2.254 2.294 2.475 2.689 2.770 0.68 2.234 2.198 2.250 2.398 2.523 2.550 0.70 2.198 2.202 2.142 2.208 2.314 2.356 0.72 2.145 2.143 2.085 2.149 2.179 2.128 0.74 2.254 2.230 2.146 2.202 2.230 2.180 0.76 2.273 2.247 2.126 2.186 2.226 2.188 0.78 2.200 2.208 2.189 2.273 2.243 2.111 0.80 2.233 2.255 2.257 2.357 2.339 2.215 0.82 2.198 2.219 2.300 2.408 2.398 2.276 0.84 1.996 2.292 2.410 2.516 2.506 2.382 0.86 2.046 2.371 2.470 2.582 2.583 2.466 0.88 1.962 2.248 2.344 2.478 2.506 2.410 0.90 1.786 2.042 2.170 2.334 2.384 2.303 0.92 1.728 2.006 2.182 2.362 2.408 2.319 0.94 1.789 2.112 2.308 2.478 2.509 2.409 0.96 1.795 2.133 2.317 2.469 2.497 2.402 0.98 1.691 2.009 2.169 2.313 2.358 2.282 1.00 1.567 1.889 2.132 2.247 2.248 2.176 1.05 1.487 1.787 2.004 2.235 2.265 2.202 1.10 1.322 1.662 1.914 2.136 2.270 2.188 1.15 1.310 1.678 1.969 2.233 2.353 2.284 1.20 1.279 1.485 1.779 2.053 2.177 2.252 1.25 1.364 1.479 1.623 1.894 2.170 2.286 1.30 1.350 1.456 1.575 1.818 2.093 2.221 1.35 1.303 1.399 1.493 1.719 1.976 2.100 1.40 1.283 1.349 1.451 1.686 1.930 2.050 1.45 1.274 1.328 1.407 1.622 1.851 1.967 1.50 1.234 1.309 1.434 1.592 1.800 1.947 1.55 1.321 1.366 1.439 1.622 1.788 1.884 1.60 1.308 1.351 1.391 1.534 1.677 1.737 1.65 1.305 1.347 1.369 1.504 1.650 1.718 1.70 1.326 1.406 1.410 1.497 -

1.605 1.650 1.75 1.279 1.358 1.350 1.422 1.520 1.562 1.80 1.330 1.405 1.377 1.434 1.523 1.561 1.85 1.399 1.458 1.443 1.467 1.511 1.547 1.90 1.331 1.457 1.487 1.544 1.582 1.573 1.95 1.269 1.A76 1.544 1.598 1.630 1.627 2.00 1.319 1.548 1.605 1.722 1.826 1.842 2.05 1.326 1.531 1.602 1.740 1.861 1.891 2.10 1.165 1.367 1.531 1.656 1.708 1.752 2.15 1.088 1.360 1.527 1.652 1.736 1.765 2.20 1.069 1.338 1.506 1.653 1.773 1.806 2.25 1.039 1.334 1.566 1.736 1.835 1;843 2.30 0.999 1.296 1.511 1.675 1.808 1.848 2.35 0.948 1.193 1.398 1.636 1.808 1.851 2.40 0.889 1.152 1.385 1.623 1.797 1.842 2.50 0.844 1.106 1.336 1.572 1.747 1.796 2.60 0.786 1.038 1.261 1.490 1.663 1.715

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 106 of 196 Date: 11/06/02 2.70 0.715 0.953 1.166 1.416 1.632 1.710 2.80 0.638 0.858 1.058 1.265 1.442 1.554 2.90 0.565 0.758 0.980 1.272 1.533 1.646 3.00 0.527 0.705 0.926 1.201 1.453 1.575 3.10 0.489 0.657 0.860 1.141 1.413 1.570 3.20 0.452 0.613 0.792 1.022 1.263 1.398 3.30 0.421 0.579 0.750 0.949 1.126 1.215 3.40 0.397 0.545

-0.708 0.897 1.074 1.201 3.50 0.381 0.512 0.665 0.843 1.042 1.173 3.60 0.349 0.479 0.622 0.789 0.938 1.062 3.70 0.325 0.446 0.579 0.735 0.875 0.982 3.80 0.315 0.413 0.548 0.716 0.879 0.979 3.90 0.331 0.435 0.549 0.707 0.885 0.999 4.00 0.330 0.438 0.559 0.711 0.860 0.972 4.10 0.305 0.410 0.526 0.674 0.819 0.908 4.20 0.265 0.359 0.463 0.595 0.726 0.805 4.30 0.240 0.319 0.405 0.517 0.638 0.724 4AO 0.228 0.306 0.393 0.504 0.622 0.704 4.50 0.207 0.280 0.364 0.469 0.579 0.656 4.60 0.191 0.259 0.335 0.430 0.529 0.600 4.70 0.205 0.259 0.326 0.426 0.528 0.592 4.80 0.216 0.278 0.339 0.422 0.529 0.597 4.90 0.215 0.280 0.347 0.428 0.507 0.567 5.00 0.203 0.268 0.335 0.417 0.497 0.544 5.10 0.188 0.249 0.314 0.393 0.470 0.515 5.20 0.173 0.231 0.294 0.369 0.442 0.485 5.40 0.157 0.212 0.271 0.344 0.414 0456 5.60 0.139 0.190 0.247 0.319 0.389 0.433 5.80 0.132 0.169 0210 0.264 0.319 0.360 6.00 0.136 0.177 0.221 0.279 0.338 0.374 6.20 0.121 0.160 0.202 0.257 0.313 0.349 6.40 0.109 0.137 0.170 0.213 0.256 0.282 6.60 0.098 0.128 0.159 0.199 0.241 0.267 6.80 0.091 0.118 0.147 0.185 0.224 0.248 7.00 0.090 0.116 0.149 0.193 0.236 0.262 7.20 0.085 0.108 0.134 0.175 0.216 0.242 7.40 0.083 0.106 0.130 0.159 0.192 0.212 7.60 0.075 0.092 0.113 0.144 -0.176 0.196 7.80 0.072 0.089 0.107 0.134 0.163 0.183 8.00 0.067 0.084 0.101 0.126 0.153 0.171 8.50 0.055 0.070 0.086 0.108 0.130 0.143 9.00 0.056 0.073 0.092 0.114 0.135 0.147 9.50 0.055 0.070 0.086 0.105 0.124 0.134 10.00 0.048 0.062 0.076 0.094 0.111 0.121

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 107 of 196 Date: 11/06/02 Table A-6. Normalized spectral ACCs for lower bound profile, earthquake 3 Period Input PGA (sec) 0.6 0.8 1.0 12 1.2 1.4x 1.62 0.01 1.000 1.000 1.000 1.000 1.000 1.000 0.03 1.003 1.002 1.002 1.002 1.002 1.002 0.04 1.005 1.004 1.004 1.004 1.004 1.003 0.05 1.008 1.007 1.006 1.006 1.006 1.006 0.06 1.012 1.010 1.009 1.008 1.008 1.008 0.07 1.017 1.014 1.012 1.012 1.011 1.011 0.08 1.014 1.016 1.016 1.015 1.015 1.015 0.09 1.039 1.029 1.022 1.020 1.018 1.018 0.10 1.043 1.022 1.014 1.017 1.019 1.021 0.11 1.041 1.028 1.022 1.023 1.024 1.026 0.12 1.045 1.005 1.001 1.014 1.022 1.026 0.13 1.121 1.035 1.037 1.036 ! 1.036 1.035 0.14 1.098 1.057 1.061 1.058 1.055 1.052 0.15 1.175 1.055 1.022 1.034 1.041 1.046 0.16 1.229 1.091 1.076 1.065 1.059 1.054 0.17 1.332 1.246 1.198 1.156 1.128 1.102 0.18 1.525 1.413 1.333 1.263 1.214 1.168 0.19 1.648 1.455 1.357 1.286 1.235 1.191 0.20 1.727 1.530 1.419 1.292 1.183 1.159 0.21 1.833 1.623 1.504 1.367 1.243 1.162 0.22 1.881 1.674 1.549 1.413 1.325 1.272 0.23 2.031 1.814 1.678 1.526 1.445 1.366 0.24 2.056 1.917 1.773 1.648 1.544 1.441 0.25 2.130 1.982 1.823 1.687 1 L570 1.456-0.26 2.121 1.975 1.805 1.663 1.541 1.424 0.27 1.972 1.767 1.688 1.622 1.619 1.500 0.28 2.050 1.914 1.855 1.873 1.859 1.720 0.29 2.089 1.952 1.896 1.912 1.906 1.780 0.30 2.027 1.904 1.849 1.872 1.879 1.775 0.31 2.070 1.953 1.925 1.806 1.754 1.683 0.32 2.114 2.029 2.029 1.915 1.783 1.549 0.33 2.161 2.006 2.013 1.917 1.795 1.593 0.34 2.407 2.122 2.083 1.982 1.863 1.659 0.35 2.608 2.324 2.286 2.103 1.957 1.711 0.36 2.727 2.448 2.419 2.240 2.092 1.836 0.37 2.798 2.456 2.406 2.257 2.117 2.006 0.38 2.984 2.665 2.607 2.426 2.263 2.033 0.39 2.919 2.655 2.614 2.432 2.265 2.017 0.40 3.113 2.768 2.675 2.479 2.348 2.135 0.41 3.199 2.970 2.861 2.560 2.364 2.137 0.42 3.421 3.208 3.101 2.776 2.518 2.276 0.43 3.495 3.300 3.192 2.858 2.584 2.337 0.44 3.216 3.047 2.938 2.654 2.463 2.291 0.45 2.824 2.856 2.891 2.756 2.630 2.465 0.46 2.883 2.997 3.063 2.942 2.745 2.495 0.47 3.016 3.158 3.245 3.126 2.923 2.573 0.48 3.047 3.223 3.328 3.220 3.023 2.670 0.49 2.940 3.148 3.275 3.186 3.026 2.790 0.50 2.729 2.990 3.158 3.168 3.071 2.874 0.51 2.687 2.916 3.089 3.125 3.090 2.917 0.52 2.513 2.778 2.954 2.984 2.912 2.750 0.53 2.332 2.596 2.775 2.814 2.784 2.758

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 108 of 196 Date: 11/06/02 0.54 2.225 2.413 2.667 2.868 2.967 2.993 0.55 2.312 2.510 2.761 2.954 3.044 3.056 0.56 2.284 2.478 2.717 2.900 2.979 2.985 0.57 2.185 2.369 2.592 2.762 2.870 2.973 0.58 2.080 2.235 2.473 2.706 2.862 2.977 0.60 2.005 2.141 2.363 2.593 2.744 2.850 0.62 1.929 2.070 2.194 2.328 2.433 2.555 0.64 2.079 2.087 2.209 2.327 2.400 2.515 0.66 2.213 2.129 2.116 2.226 2.287 2.382 0.68 2.116 2.104 1.973 1.997 2.044 2.113 0.70 2.137 1.990 1.923 1.945 2.040 2.160 0.72 2.240 2.109 2.057 2.046 2.012 2.136 0.74 2.151 2.041 2.001 2.011 2.000 2.000 0.76 2.072 2.079 1.952 1.945 1.949 1.963 0.78 2.184 2.226 2.094 1.929 1.885 1.874 0.80 2.262 2.305 2.178 2.018 1.970 1.934 0.82 2.262 2.315 2.198 2.064 2.014 1.974 0.84 2.221 2.286 2.180 2.088 2.038 1.994 0.86 2.142 2.216 _ 2.123 2.088 2.040 1.993 0.88 2.004 2.088 2.012 2.036 i.998 1.952 0.90 1.826 1.922 1.891 1.944 1.919 1.877 0.92 1.662 1.775 1.860 1.861 1.848 1.808 0.94 1.543 1.878 2.025 1.961 1.817 1.775 0.96 1.600 1.987 2.143 2.083 1.910 1.778 0.98 1.666 2.051 2.215 2.162 1.985 1.832 1.00 1.689 2.070 2.242 2.196 2.015 1.858 1.05 1.557 1.899 2.101 2.159 2.087 1.976 1.10 1.478 1.636 1.838 1.957 2.010 2.020 1.15 1.576 1.757 1.919 2.061 2.131 2.141 1.20 1.588 1.778 1.937 2.071 2.135 2.146 1.25 1.549 1.738 1.889 2.014 2.075 2.088 1.30 1.516 1.703 1.848 1.970 2.049 2.131 1.35 1.469 1.654 1.795 1.912 1.974 2.044 1.40 1.413 1.593 1.726 1.837 1.895 1.915 1.45 1.393 1.568 1.695 1.802 1.861 1.882 1.50 1.401 1.575 1.702 1.811 1.875 1.901 1.55 1.384 1.561 1.689 1.802 1.871 1.901 1.60 1.327 1.503 1.631 1.743 1.815 1.847 1.65 1.260 1.434 1.559 1.667 1.738 1.768 1.70 1.258 IAOI 1.521 1.624 1.693 1.721 1.75 1.297 IA18 1.535 1.636 1.703 1.732 1.80 1.319 1 A59 1.575 1.675 1.746 1.776 1.85 1.320 1.486 1.601 1.704 1.780 1.816 1.90 1.314 1.476 1.593 1.702 1.786 1.831 1.95 1.307 1.473 1.561 1.679 1.771 1.822 2.00 1.291 1.464 1.552 1.647 1.740 1.793 2.05 1.262 1.421 1.534 1.611 1.696 1.748 2.10 1.241 1.372 1.515 1.616 1.664 1.698 2.15 1.106 1.364 1.532 1.614 1.677 1.685 2.20 1.092 1.391 1.564 1.649 1.682 1.701 2.25 1.091 1.386 1.561 1.655 1.683 1.714 2.30 1.069 1.354 1.531 1.641 1.684 1.726 2.35 1.025 1.301 1.487 1.613 1.684 1.735 2.40 0.965 1.238 1.435 1.570 1.676 1.731 2.50 0.835 1.1011.315 1.4921.610 1.670 2.60 0.846 1.144 1.415 1.627 1.726 1.730

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 109 of 196 Date: 11/06/02 2.70 0.791 1.091 1.361 1.574 1.702 1.733 2.80 0.705 0.979 1.249 1.487 1.621 1.653 2.90 0.605 0.835 1.077 1.300 1.471 1.551 3.00 0.573 0.787 0.978 1.206.

1.365 1.439 3.10 0.537 0.746 0.936 1.110 1.236 1.312 3.20 0.499 0.696 0.876 1.041 1.161 1.246 3.30 0.458 0.637 0.803 0.957 1.111 1.218 3.40 0.468 0.631 0.792 0.972 1.136 1.254 3.50 0.465 0.632 0.798 0.971 1.118 1.237 3.60 0.413 0.566 0.718 0.878 1.014 1.116 3.70 0.350 0.477 0.609 0.750 0.872 0.962 3.80 0.325 0.432 0.541 0.667 0.780 0.864 3.90 0.319 0.427 0.538 0.659 0.765 0.846 4.00 0.306 0.415 0.530 0.656 0.766 0.851 4.10 0.268 0.374 0.484 0.603 0.707 0.786 4.20 0.247 0.333 0.432 0.554 0.656 0.730 4.30 0.244 0.331 0.417 0.535 0.636 0.712 4.40 0.239 0.325

.406 0.510 0.609 0.685 4.50 0.230 0.314 0.394 0.480 0.576 0.650 4.60 0.218 0.299 0.383 0.469 0.540 0.612 4.70 0.213 0.287 0.368 0.452 0.523 0.575 4.80 0.196 0.272 0.350 0.431 0.499 0.548 4.90 0.187 0.254 0.328 0.405 0.470 0.518 5.00 0.182 0.234 0.303 0.376 0.437 0.483 5.10 0.175 0.215 0.277 0.344 0.402 0.445 5.20 0.178 0.229 0.282 0.340 0.392 0.431 5.40 0.179 0.234 0.291 0.354 0.410 0.454 5.60 0.135 0.180 0.227 0.279 0.326 0.365 5.80

-0.121 0.149 0.180 0.219 0.255 0.281 6.00 0.119 0.148 0.176 0.206 0.233 0.255 6.20 0.115 0.147 0.177 0.207 0.232 0.251 6.40 0.114 0.148 0.179 0.211 0.237 0.256 6.60 0.111 0.145 0.177 0.210 0.237 0.257 6.80 0.102 0.134 0.166 0.198 0.224 0.244 7.00 0.098 0.124 0.151 0.180 0.204 0.223 7.20 0.097 0.125 0.154 0.185 0.212 0.232 7.40 0.083 0.110 0.135 0.163 0.188 0.208 7.60 0.076 0.101 0.125 0.149.

0.169 0.184 7.80 0.068 0.091 0.114 0.140 0.162 0.176 8.00 0.063 0.083 0.106 0.130 0.151 0.165 8.50 0.059 0.073 0.085 0.097 0.114 0.127 9.00 0.056 0.071 0.084 0.096 0.105 0.111 9.50 0.050 0.063 0.077 0.090 0.100 0.106 10.00 0.047 0.059 0.071 0.084 0.096 0.104

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 110 of 196 Date: 11/06/02 Table A-7. Normalized spectral ACCs for upper bound profile, earthquake 1 Period Input PGA (sec) 0.6e 0.8 1.0 e 1.2 1.4 1.62 0.01 1.000 1.000 1.000 1.000 1.000 1.000 0.03 1.016 1.012 1.009 1.006 1.005 1.005 0.04 1.039 1.025 1.018 1.014 1.010 1.009 0.05 1.056 1.043 1.032 1.025 1.016 i.015 0.06 1.069 1.054 11.042 1.036 1.024 1.022 0.07 1.150 1.104 1.076 1.060 1.034 1.030 0.08 1.287 1.203 1.149 1.114 1.048 1.040 0.09 1.312 1.113 1.100 1.133 1.101 1.078 0.10 1.398 1.219 1.188 1.191 1.144 1.117 0.11 1.524 1.425 1.354 1.285 1.168 1.090 0.12 1.609 1.519 1.436 1.351 1.223 1.137 0.13 1.579 1.495 1.325 1.235 1.140 1.083 0.14 1.707 1.537 1.462 1.409 1.273 1.180 0.15 I 1.795 1.778 1.693 1.586 1.408 1.313 0.16 1.910 1.771 1.666 1.653 1.564 1.475 0.17 2.228 2.038 1.767 1.680 1.530 1.472 0.18 2.118 1.899 1.747 1.692 1.549 1.415 0.19 2.219 1.930 1.944 1.960 1.736 1.503 0.20 2.419 2.014 2.078 2.138 1.925 1.694 0.21 2.827 2.351 2.214 2.176 1.987 1.811 0.22 2.886 2.556 2.415 2.367 2.166 1.986 0.23 2.748 2.508 2.393 2.345 2.144 1.973 0.24 3.089 2.758 2.556 2.395 2.184 2.015 0.25 3.251 3.149 2.837 2.581 2.313 2.104 0.26 3.425 3.397 3.139 2.815 2.322 2.145 0.27 3.311 3.364 3.178 2.908 2.422 2.160 0.28 3.103 3.227 3.115 2.903 2.573 2.332 0.29 2.784 2.969 3.059 3.139 2.890 2.600 0.30 2.587 2.860 2.995 3.002 2.873 2.760 0.31 2.520 2.612 2.798 3.062 3.017 2.900 0.32 2.500 2.618 2.741 2.973 2.918 2.797 0.33 2.442 2.578 2.617 2.652 2.594 2.485 0.34 2.355 2.495 2.536 2.505 2.378 2.301 0.35 2.286 2A19 2.458 2.428 2.311 2.252 0.36 2.275 2.404 2.448 2.423 2.322 2.291 0.37 2.275 2.415 2.478 2A72 2.392 2.388 0.38 2.225 2.375 2.455 2.467 2.405 2.416 0.39 2.207 2.324 2.416 2.443 2.396 2.423 0.40 2.278 2.259 2.369 2.416 2.391 2.490 0.41 2.317 2.192 2.239 2.312 2.409 2.575 0.42 2.245 2.165 2.043 2.164 2.289 2.483 0.43 2.268 2.169 2.075 1.981 2.081 2.291 0.44 2.219 2.187 2.116 1.927 1.916 2.090 0.45 2.182 2.242 2.184 2.003 1.896 1.955 0.46 2.233 2.305 2.256 2.084 1.905 1.956 0.47 2.272 2.348 2.309 2.149 1.973 1.954 0.48 2.264 2.342 2.313 2.171 2.006 1.944 0.49 2.173 2.245 2.237 2.126 1.977 1.919 0.50 2.006 2.079 2.100 2.028 1.897 1.845 0.51 1.843 1.926 1.983 1.944 1.827 1.776 0.52 1.755 1.859 1.950 1.930 1.813 1.759 0.53 1.736 1.863 1.976 1.963 1.842 1.784 I

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 111 of 196 Date: 11/06/02 0.54 1.736 1.879 2.009 2.001 1.877 1.816 0.55 1.738 1.895 2.041 2.040 1.914 1.849 0.56 1.750 1.922 2.087 2.092 1.960 1.933 0.57 1.775 1.948 2.130 2.215 2.121 2.033 0.58 1.802 1.953 2.176 2.420 2.333 2.253 0.60 1.677 1.851 2.245 2.515 2.459 2.422 0.62 1.586 1.775 2.109 2.497 2.529 2.534 0.64 1.544 1.777 2.126 2.520 2.576 2.609 0.66 1.566 1.701 2.044 2.433 2.504 2.553 0.68 1.588 1.685 1.830 2.190 2.270 2.353 0.70 1.607 1.705 1.850 2.084 2.172 2.266 0.72 1.619 1.718 1.865 2.062 2.166 2.275 0.74 1.618 1.717 1.866 2.031 2.022 2.115 0.76 1.605 1.703 1.851 2.018 2.012 2.042 0.78 1.582 1.678 1.825 1.992 1.987 2.018 0.80 1.554 1.647 1.792 1.958 1.954 1.986 0.82 1.551 1.614 1.756 1.920 1.918 1.950 0.84 1.560 1.580 1.718 1.881 1.879 1.911 0.86 1.567 1.583 1.680 1.840 1.839 1.875 0.88 1.573 1.586 1.657 1.798 1.800 1.849 0.90 _

1.576 1.589 1.652 1.778 1.777 1.822 0.92 1.577 1.591 1.649 1.763 1.755 1.794 0.94 1.580 1.592 1.646 1.749 1.734 1.768 0.96 1.614 1.605 1.643 1.738 1.715 1.743 0.98 1.640 1.637 1.651 1.727 1.698 1.720 1.00 1.659 1.660 1.680 1.716 1.682 1.697 1.05 1.681 1.679 1.710 1.737 1.643 1.635 1.10 1.748 1.757 1.761 1.752 1.638 1.585 1.15 1.722 1.752 1.775 1.781 1.669 1.612 1.20 1.721 1.768 1.817 1.834 1.721 1.659 1.25 1.559 1.642 1.700 1.718 1.641 1.625 1.30 1.316 1.500 1.681 1.829 1.793 1.786 1.35 1.218 1.426 1.659 1.893 1.883 1.886 1.40 1.244 1.457 1.714 1.964 1.974 1.977 1.45 1.175 1.372 1.624 1.893 1.930 1.959 1.50 1.117 1.303 1.555 1.843 1.902 1.949 1.55 1.081 1.265 1.520 1.820 1.893 1.952 1.60 1.038 1.219 1.472 1.771 1.852 1.922 1.65 0.970 1.142 1.384 1.676 1.794 1.906 1.70 0.885 1.044 1.272 1.565 1.716 1.840 1.75 0.809 0.948 1.162 1.444 1.597 1.728 1.80 0.762 0.892 1.082 1.340 1.461 1.589 1.85 0.722 0.846 1.029 1.275 1.389 1.516 1.90 0.684 0.803 0.981 1.223 1.330 1.442 1.95 0.641 0.755 0.927 1.162 1.270 1.381 2.00 0.603 0.703 0.861 1.085 1.190 1.299 2.05 0.584 0.679 0.822 1.019 1.112 1.219 2.10 0.559 0.650 0.787 0.978 1.069 1.173 2.15 0.529 0.616 0.747 0.930 1.019 1.120 2.20 0.497 0.580 0.705 0.880 0.967 1.064 2.25 0.465 0.544 0.664 0.832 0.915 1.010 2.30 0.435 0.511 0.625 0.785 0.867 0.958 2.35 0.407 0.479 0.588 0.742 0.821 0.910 2.40 0.381 0.449 0.553 0.701 0.778 0.864 2.50 0.360 0.409 0.487 0.623 0.696 0.779 2.60 0.340 0.387 0.458 0.557 0.621 0.699

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 112 of 196 Date: 11/06/02 2.70 0.321 0.366 0.433 0.526 0.568 0.625 2.80 0.304 0.346 0.409 0.498 0.538 0.584 2.90 0.288 0.328 0.389 0.474 0.512 0.557 3.00 0.275 0.313 0.371 0.453 0.489 0.533 3.10 0.263 0.300 0.356 0.434 0.470 0.513 3.20 0.253 0.288 0.342 0.418 0.453 0.495 3.30 0.242 0.276 0.328 OA02 0.436 0.477 3.40 0.230 0.264 0.314 0.385 0.419 0.459 3.50 0.218 0.250 0.298 0.366 0.399 0.439 3.60 0.205 0.235 0.281 0.346 0.378 0.416 3.70 0.191 0.219 0.262 0.324 0.355 0.392 3.80 0.175 0.202 0.243 0.301 0.331 0.366 3.90 0.167 0.188 0.222 0.277 0.305 0.338 4.00 0.159 0.179 0.212 0.258 0.279 0.311 4.10 0.150 0.168 0.199 0.244 0.264 0.287 4.20 0.139 0.156 0.184 0.227 0.248 0.271 4.30 0.127 0.143 0.169 0.209 0.229 0.251 4.40 0.125 0.138 0.158 0.190 0.209 0.230 4.50 0.127 0.141 0.161 0.192 0.206 0.225 4.60 0.124 0.136 0.157 0.187 0.200 0.218 4.70 0.115 0.126 0.145 0.173 0.186 0.203 4.80 0.105 0.116 0.132 0.155 0.166 0.181 4.90 0.104 0.116 0.132 0.156 0.166 0.180 5.00 0.101 0.112 0.129 0.153 0.164 0.177 5.10 0.097 0.108 0.124 0.149 0.159 0.173 5.20 0.093 0.103 0.119 0.143 0.154 0.167 5.40 0.087 0.096 0.109 0.129 0.139 0.152 5.60 0.081 0.089 0.101 0.120 0.128 0.138 5.80 0.074 0.082 0.094 0.111 0.119 0.129 6.00 0.067 0.075 0.086 0.103 0.111 0.121 6.20 0.062 0.069 0.080 0.096 0.104 0.113 6.40 0.059 0.065 0.075 0.090 0.097 0.106 6.60 0.061 0.067 0.077 0.091 0.097 0.106 6.80 0.061 0.067 0.076 0.090 0.097 0.105 7.00 0.059 0.065 0.074 0.087 0.093 0.101 7.20 0.055 0.060 0.069 0.082 0.087 0.095 7.40 0.054 0.059 0.067 0.079 0.085 0.092 7.60 0.051 0.056 0.064 0.076 0.081 0.088 7.80 0.048 0.053 0.060 0.071 0.076 0.082 8.00 0.045 0.049 0.055 0.065 0.070 0.075 8.50 0.035 0.038 0.044 0.052 0.055 0060 9.00 0.029 0.032 0.037 0.044 0.047 0.051 9.50 0.023 0.025 0.029 0.035 0.037 0041 10.00 0.019 0.021 0.023 0.027 0.029 0.032

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 113 of 196 Date: 11/06/02 Table A-8. Normalized spectral ACCs for upper bound profile, earthquake 2 Period Invu PGA (sece 0.6 j.j 1.0 1.2x 1.4 I.

0.01 1.000 1.000 1.000 1.000 1.000 1.000 0.03 1.012 1.013 1.006 1.004 1.001 1.002 0.04 1.024 1.030 1.012 1.007 1.002 1.004 0.05 1.047 1.045 1.012 1.013 1.003 1.006 0.06 1.046 1.086 1.011 1.014 1.008 1.006 0.07 1.197 1.227 1.046 1.020 1.005 1.010 0.08 1.269 1.249 1.111 1.006 1.026 1.018 0.09 1.564 1.527 1.323 1.167 1.038 1.046 0.10 1.648 1.629 1.430 1.272 1.122 1.041 0.11 1.701 1.687 1.491 1.327 1.177 1.031 0.12 1.810 1.813 1.602 1.429 1.266 1.105 0.13 2.224 2.300 1.865 1.531 1.365 1.196 0.14 2.342 2.454 2.024 1.595 1.312 1.185 0.15 2.447 2.577 2.163 1.725 1.377 1.162 0.16 2.507 2.700 2.297 1.850 1.486 1.189 0.17 2.630 2.827 2.454 1.991 1.616 1.298 0.18 2.641 2.953 2.620 2.137 1.746 1.415 0.19 3.030 3.080 2.689 2.397 2.085 1.755 0.20 3.189 3.323 2.994 2.676 2.349 1.999 0.21 3.231 3.396 3.073 2.764 2.450 2.109 0.22 3.485 3.504 3.175 2.866 2.560 2.222 0.23 3.794 3.935 3.268 2.972 2.673 2.334 0.24 3.619 3.892 3.326 3.040 2.752 2.423 0.25 3.672 3.958 3.438 3.092 2.820 2.499 0.26 3.449 3.740 3.377 3.123 2.865 2.557 0.27 3.440 3.923 3.641 3.149 2.908 2.611 0.28 3.438 3.995 3.756 3.256 2.934 2.647 0.29 3.397 3.642 3.514 3.184 2.933 2.661 0.30 3.335 3.567 3.295 3.087 2.884 2.633 0.31 3.245 3.464 3.191 2.991 2.809 2.586 0.32 3.161 3.359 3.087 2.898 2.738 2.543 0.33 3.101 3.283 3.011 2.835 2.696 2.526 0.34 3.067 3.240 2.966 2.802 2.697 2.630 0.35 3.051 3.214 2.936 2.785 2.681 2.598 0.36 3.034 3.187 2.908 2.768 2.677 2.562 0.37 3.008 3.149 2.872 2.740 2.662 2.561 0.38 2.974 3.104 2.823 2.699 2.638 2.551 0.39 2.932 3.046 2.761 2.647 2.600 2.528 0.40 2.884 2.980 2.690 2.584 2.548 2.494 0.41 3.044 2.899 2.602 2.504 2.485 2.447 0.42 3.159 3.003 2.496 2.408 2.402 2.381 0.43 3.161 3.024 2.459 2.288 2.297 2.295 0.44 3.053 2.924 2.401 2.143 2.165 2.181 0.45 3.333 3.164 2.447 2.140 2.010 2.043 0.46 3.515 3.399 2.668 2.276 2.100 2.066 0.47 3.377 3.345 2.695 2.341 2.123 1.993 0.48 3.093 3.151 2.685 2.360 2.172 2.037 0.49 3.075 3.216 2.787 2.462 2.276 2.150 0.50 2.802 3.185 2.793 2.480 2.298 2.181 0.51 2.705 3.168 2.834 2.470 2.282 2.172 0.52 2.675 3.196 2.897 2.549 2.283 2.158 0.53 2.683 3.221 2.950 2.616 2.357 2.163

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 114 of 196 Date: 11/06/02 0.54 2.679 3.235 2.985 2.661 2.414 2.223 0.55 2.635 3.199 2.969 2.661 2.428 2.248 0.56 2.529 3.087 2.883 2.596 2.384 2.222 0.57 2.366 2.901 2.725 2.467 2.282 2.142 0.58 2.211 2.671 2.671 2.491 2.287 2.112 0.60 2.385 2.914 2.940 2.726 2.476 2.256 0.62 2.213 2.700 2.713 2.562 2.470 2.356 0.64 1.945 2.465 2.582 2.543 2.458 2.347 0.66 1.990 2.536 2.643 2.603 2.551 2.482 0.68 2.083 2A87 2.647 2.627 2.578 2.509 0.70 2.131 2.558 2.561 2.472 2.409 2.348 0.72 2.058 2.472 2.478 2.387 2.298 2.215 0.74 2.098 2.520 2.539 2.454 2.370 2.297 0.76 2.073 2.499 2.541 2.469 2.391 2.323 0.78 1.987 2.398 2.448 2.382 2.307 2.239 0.80 1.963 2.371 2.434 2.378 2.310 2.248 0.82 1.967 2.261 2.337 2.300 2.244 2.190 0.84 2.054 2.365 2.308 2.176 2.066 1.997 0.86 2.110 2.441 2.399 2.274 2.165 2.093 0.88 2.030 2.361 2.334 2.222 2.117 2.044 0.90 1.913 2.230 2.206 2.099 1.996 1.919 0.92 1.933 2.244 2.212 2.099 1.991 1.908 0.94 2.028 2.346 2.309 2.193 2.081 1.995 0.96 2.021 2.340 2.309 2.200 2.094 2.011 0.98 1.947 2.204 2.184 2.087 1.990 1.912 1.00 1.917 2.132 2.064 1.973 1.879 1.802 1.05 2.091 2.304 2.161 1.986 1.868 1.785 1.10 2.171 2A18 2.216 1.996 1.847 1.728 1.15 2.200 2.449 2.325 2.151 1.989 1.854 1.20 2.017 2.467 2.475 2.356 2.224 2.096 1.25 2.027 2A64 2.466 2.368 2.254 2.142 1.30 1.879 2.330 2.380 2.299 2.183 2.064 1.35 1.750 2.247 2.335 2.283 2.190 2.079 IA0 1.671 2.153 2.280 2.249 2.173 2.075 1.45 1.592 2.068 2.209 2.193 2.131 2.044 1.50 1.497 1.958 2.105 2.100 2.049 1.974 1.55 1.383 1.817 1.965 1.970 1.937 1.907 1.60 1.277 1.660 1.830 1.898 1.927 1.921 1.65 1.287 1.675 1.854 1.926 1.958 1.954 1.70 1.211 1.584 1.761 1.832 1.863 1.858 1.75 1.064 1.398 1.559 1.624 1.654 1.653 1.80 0.982 1.301 1.460 1.530 1.570 1.606 1.85 1.002 1.321 1.487 1.578 1.650 1.699 1.90 0.952 1.264 1.430 1.522 1.595 1.644 1.95 0.851 1.139 1.294 1.380 1.448 1.494 2.00 0.777 1.030 1.157 1.241 1.314 1.374 2.05 0.735 0.967 1.088 1.167 1.252 1.325 2.10 0.730 0.946 1.038 1.078 1.129 1.192 2.15 0.713 0.928 1.024 1.067 1.104 1.137 2.20 0.686 0.897 0.995 1.041 1.080 1.113 2.25 0.650 0.855 0.953 1.001 1.042 1.076 2.30 0.608 0.803 0.901 0.950 0.991 1.026 2.35 0.561 0.745 0.839 0.888 0.930 0.966 2.40 0.540 0.696 0.770 0.819 0.861 0.896 2.50 0.516 0.664 0.731 0.766 0.798 0.829 2.60 0.477 0.613 0.676 0.709 0.740 0.769

Calc Number: GEO{BIP.02.06 Rev Number: 0 Sheet Number: 115 of 196 Date: 11/06/02 2.70 0.425 0.550 0.607 0.638 0.667 0.695 2.80 0.379 0.483 0.531 0.559 0.587 0.613 2.90 0.375 0.479 0.514 0.524 0.542 0.561 3.00 0.337 0.435 0.476 0.490 0.508 0.527 3.10 0.340 OA34 0.472 0.487 0.500 0.510 3.20 0.302 0.390 0.428 0.445 0.461 0.474 3.30 0.284 0.357 0.382 0.393 0.406 0.418 3.40 0.269 0.338 0.367 0.384 0.399 0.412 3.50 0.252 0.318 0.340 0.356 0.373 0.387 3.60 0.235 0.297 0.318

-0.327 0.337 0.346 3.70 0.218 0.284 0.313 0.324 0.332 0.337 3.80 0.221 0.288 0.319 0.331 0.340 0.347 3.90 0.226 0.292 0.323 0.337 0.349 0.357 4.00 0.220 0.281 0.310 0.325 0.338 0.347 4.10 0.198 0.253 0.277 0.291 0.304 0.314 4.20 0.176 0.222 0.238 0.246 0.258 0.268 4.30 0.179 0.226 0.242 0.248 0.254 0.259 4.40 0.170 0.214 0.229 0.235 0.240 0.245 4.50 0.159 0.200 0.213 0.218 0.222 0.225 4.60 0.150 0.189 0.203 0.208 0.212 0.215 4.70 0.159 0.203 0.219 0.225 0.231 0.234 4.80 0.161 0.206 0.223 0.231 0.237 0.242 4.90 0.153 0.196 0.214 0.222 0.229 0.235 5.00 0.141 0.179 0.195 0.203 0.211 0.217 5.10 0.129 0.162 0.176 0.183 0.190 0.196 5.20 0.119 0.149 0.160 0.167 0.173 0.179 5.40 0.110 0.136 0.145 0.149 0.155 0.160 5.60 0.111 0.138 0.143 0.143 0.142 0.140 5.80 0.108 0.137 0.146 0.147 0.148 0.148 6.00 0.107 0.137 0.147 0.150 0.151 0.152 6.20 0.101 0.127 0.134 0.135 0.136 0.135 6.40 0.098 0.124 0.132 0.134 0.135 0.136 6.60 0.081 0.104 0.112 0.114 0.116 0.117 6.80 0.078 0.095 0.098 0.100 0.102 0.103 7.00 0.076 0.094 0.099 0.100 0.101 0.102 7.20 0.073 0.091 0.096 0.098 0.099 0.100 7.40 0.069 0.086 0.092 0.093 0.095 0.096 7.60 0.066 0.082 0.088 0.089 0.090 0.091 7.80 0.062 0.077 0.083 0.084 0.085 0.086 8.00 0.057 0.071 0.076 0.078 0.079 0.080 8.50 0.049 0.060 0.062 0.062 0.062 0.062 9.00 0.047 0.059 0.062 0.063 0.063 0.064 9.50 0.047 0.058 0.062 0.063 0.064 0.064 10.00 0.039 0.048 0.052 0.053 0.054 0.055

'1

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 116 of 196 Date: 11/06/02 Table A-9. Normalized spectral ACCs for upper bound profile, earthquake 3 Period In ut PGA (see) 06 g

.8 g 1.0 g 1.2 g 1.4 g 1.6 g 0.01 1.000 1.000 1.000 1.000 1.000 1.000 0.03 1.008 1.007 1.006 1.004 1.003 1.002 0.04 1.016 1.013 1.011 1.008 1.006 1.004 0.05 1.025 1.021 1.018 1.013 1.009 1.006 0.06 1.045 1.035 I1.029 1.022 1.015 1.009 0.07 1.063 1.051 11.041 1.031 1.021 1.013 0.08 1.040 1.045 1.045 1.036 1.024 1.013 0.09 1.149 1.114 1.089 1.065 1.045 1.029 0.10 1.363 1.243 1.172 1.114 1.073 1.038 0.11 1.272 1.195 1.153 1.123 1.087 1.047 0.12 1.423 1.291 1.231 1.174 1.107 1.043 0.13 1.447 1.195 1.147 1.102 1.089 1.087 0.14 1.484 1.225 1.107 1.041 1.051 1.062 0.15 1.629 1.384 1.278 1.168 1.099

-1.052 0.16 1.804 1.630 1.503 1.369 1.204 1.129 0.17 1.887 1.643 1.523 1.401 1.297 1.281 0.18 1.940 1.698 1.530 1.480 1.468 1.438 0.19 1.979 1.721 1.573 1.519 1.460 1.434 0.20 2.082 1.748 1.638 1.578 1.513 1.424 0.21 2.216 1.834 1.715 1.655 1.584 1.484 0.22 2.538 1.989 1.842 1.719 1.597 1.495 0.23 2.689 2.133 1.881 1.794 1.682 1.603 0.24 2.922 2.510 2.220 2.009 1.874 1.762 0.25 3.148 2.756 2.456 2.193 1.996 1.834 0.26 3.308 2.935 2.626 2.317 2.062 1.848 0.27 3.127 2.796 2.520 2.246 2.028 1.768 0.28 3.218 3.045 2.870 2.660 2.401 2.091 0.29 3.118 3.007 2.862 2.673 2.438 2.152 0.30 2.898 2.861 2.747 2.582 2.376 2.119 0.31 2.570 2.642 2.700 2.635 2.442 2.142 0.32 2.245 2.385 2.546 2.547 2.383 2.165 0.33 2.189 2.262 2.417 2.418 2.287 2.074 0.34 2.178 2.153 2.277 2.437 2.393 2.260 0.35 2.167 2.195 2.367 2.536 2.496 2.269 0.36 1.892 1.967 2.151 2.302 2.409 2.316 0.37 1.858 1.777 2.008 2.292 2.470 2.487 0.38 1.891 1.965 2.058 2.304 2.483 2.513 0.39 1.805 1.891 2.049 2.277 2.467 2.477 0.40 1.870 1.702 1.863 2.084 2.282 2.377 0.41 1.913 1.666 1.794 2.019 2.227 2.334 0.42 2.039 1.731 1.803 2.046 2.223 2.380 OA3 2.140 1.811 1.829 2.068 2.258 2.399 0.44 2.062 1.766 1.744 1.951 2.140 2.245 OA5 2.097 1.804 1.768 1.817 1.886 1.964 0.46 2.148 1.872 1.854 1.924 1.994 2.067 0.47 2.180 1.871 1.862 1.941 2.010 2.079 0.48 2.248 1.908 1.827 1.909 1.972 2.032 0.49 2.329 1.980 1.867 1.934 1.994 2.048 0.50 2.354 2.106 2.020 2.004 2.028 2.081 0.51 2.387 2.151 2.082 2.088 2.044 2.024 0.52 2.254 2.050 2.006 2.033 2.006 1.941 0.53 2.032 1.955 1.990 2.061 2.063 2.023

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 117 of 196 Date: 11/06/02 0.54 2.057 2.112 2.128 2.183 2.195 2.173 0.55 2.120 2.146 2.174 2.267 2.272 2.212 0.56 2.076 2.184 2.290 2.388 2.402 2.341 0.57 2.013 2.209 2.311 2.410 2.430 2.378 0.58 1.994 2.169 2.267 2.367 2.392 2.348 0.60 1.934 2.037 2.106 2.205 2.237 2.205 0.62 1.841 1.944 2.018 2.088 2.110 2.062 0.64 1.722 1.828 1.958 2.169 2.276 2.266 0.66 1.565 1.685 1.896 2.133 2.249 2.265 0.68 1.447 1.608 1.770 1.960 2.068 2.097 0.70 1.574 1.609 1.756 1.946 2.087 2.163 0.72 1.686 1.749 1.909 2.109 2.254 2.324 0.74 1.640 1.718 1.874 2.064 2.199 2.262 0.76 1.574 1.667 1.822 2.006 2.137 2.199 0.78 1.467 1.573 1.726 1.903 2.031 2.091 0.80 1.394 1.451 1.603 1.772 1.895 1.954 0.82 1.468 1.429 1.510 1.688 1.830 1.924 0.84 1.523 1.478 1.525 1.630 1.774 1.873 0.86 1.558 1.509 1.553 1.623 1.684 1.786 0.88 1.549 1.501 1.540 1.604 1.634 1.652 0.90 1.500 1.453 1.486 1.542 1.563 1.555 0.92 1.448 1.400 1.426 1.473 1.486 1.469 0.94 1.490 1.465 1.510 1.573 1.593 1.577 0.96 1.559 1.543 1.601 1.677 1.707 1.695 0.98 1.599 1.591 1.659 1.746 1.783 1.775 1.00 1.610 1.609 1.684 1.777 1.820 1.815 1.05 1.609 1.573 1.602 1.672 1.696 1.698 1.10 1.596 1.628 1.703 1.783 1.801 1.758 1.15 1.632 1.648 1.724 1.819 1.860 1.843 1.20 1.495 1.524 1.601 1.686 1.759 1.793 1.25 1.498 1.536 1.566 1.613 1.702 1.740 1.30 1.585 1.624 1.657 1.688 1.667 1.701 1.35 1.531 1.650 1.736 1.797 1.782 1.706 1.40 1.403 1.529 1.655 1.747 1.755 1.692 1.45 1.333 1.512 1.656 1.761 1.794 1.803 1.50 1.182 1.343 1.466 1.561 1.636 1.650 1.55 1.053 1.162 1.296 1.438 1.536 1.580 1.60 1.012 1.116 1.245 1.419 1.542 1.597 1.65 0.972 1.105 1.289 1.474 1.607 1.668 1.70 0.927 1.068 1.249 1.433 1.568 1.634 1.75 0.891 1.030 1.204 1.389 1.528 1.602 1.80 I 0.858 I 1.011 I 1.175 1.350 1.487 1.566 1.85 0.859 0.964 1.091 1.257 1.388 1.464 1.90 0.843 0.952 1.084 1.229 1.347 1.422 1.95 0.805 0.915 1.046 1.190 1.307 1.382 2.00 0.751 0.858 0984 1.122 1.234 1.306 2.05 0.689 0.790 0.912 1.049 1.162 1.241 2.10 0.625 0.719 0.834 0.968 1.086 1.175 2.15 0.563 0.650 0.752 0.875 0.985 1.066 2.20 0.509 0.588 0.687 0.802 0.902 0.975 2.25 0.486 0.547 0.637 0.749 0.846 0.918 2.30 0.464 0.522 0.594 0.700 0.795 0.866 2.35 0.455 0.510 0.578 0.657 0.745 0.816 2.40 0.433 0.490 0.556 0.634 0.705 0.767 2.50 0.368 0.419 0.482 0.553 0.616_

0.672 2.60 0.383 0.432 0.497 0574 0.645 0.700

Calc Number: GEO.HBEP.02.06 Rev Number: 0 Sheet Number: 118 of 196 Date: 11/06/02 2.70 0.330 0.378 0.439 0.512 0.579 0.635 2.80 0.302 0.341 0.392 0.453 0.513 0.562 2.90 0.291 0.324 0.365 0.412 0.451 0.483 3.00 0.282 0.315 0.356 0.402 0.440 0.468 3.10 0.272 0.304 0.344 0.389 0.425 0.451 3.20 0.256 0.287-0.325 0.368 0.403 0.427 3.30 0.240 0.264 0.300 0.340 0.373 0.395 3.40 0.245 0.272 0.306 0.346 0.380 0.406 3.50 0.237 0.265 0.300 0.341 0.376 OA02 3.60 0.202 0.229 0.261 0.298 0.330 0.354 3.70 0.168 0.190 0.219 0.253 0.283 0.306 3.80 0.156 0.175 0.202 0.234 0.262 0.284 3.90 0.156 0.171 0.197 0.228 0.255 0.277 4.00 0.160 0.173 0.193 0.217 0.240 0.260 4.10 0.152 0.166 0.186 0.210 0.230 0.244 4.20 0.133 0.144 0.162 0.183 0.201 0.213 4.30 0.140 0.148 0.160 0.174 0.189 0.203 4.40 0.144 0.153 0.167 0.182 0.194 0.200 4.50 0.144 0.154 0.168 0.185 0.198 0.205 4.60 0.139 0.150 0.165 0.182 0.199 0.211 4.70 0.131 0.142 0.157 0.176 0.194 0.206 4.80 0.122 0.135 0.153 0.172 0.188 0.197 4.90 0.118 0.131 0.148 0.167 0.183 0.193 5.00 0.112 0.126 0.142 0.161 0.176 0.186 5.10 0.106 0.119 0.135 0.153 0.168 0.177 5.20 0.105 0.116 0.130 0.147 0.162 0.172 5.40 0.099 0.111 0.126 0.143 0.157 0.168 5.60 0.084 0.092 I 0.102 0.114 0.122 0.130 5.80 0.076 0.085 0.096 0.108 0.118 0.124 6.00 0.071 0.079 0.090 0.102 0.112 0.119 6.20 0.068 0.074 0.085 0.097 0.106 0.113 6.40 0.067 0.072 0.081 0.091 0.101 0.107 6.60 0.069 0.074 0.082 0.092 0.099 0.104 6.80 0.064 0.070 0.079 0.088 0.095 0.100 7.00 0.059 0.065 0.073 0.083 0.090 0.096 7.20 0.058 0.063 0.070 0.080 0.088 0.093 740 0.057 0.062 0.069 0.076 0.081 0.084 7.60 0.052 0.057 0.064 0.071 0.077 0.080 7.80 0.045 0.050 0.056 0.063 0.068 0.072 8.00 0.040 0.044 0.048 0.054 0.059 0.061 8.50 0.041 0.044 0.049 0.055 0.059 0.062 9.00 0.036 0.040 0.045 0.050 0.054 0.057 9.50 0.033 0.036 0.040 0.045 0.049 0.052 10.00 0.030 0032 0.036 0.040 0.044 0.047

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 119 of 196 Date: 11/06/02 Appendix B Input Time Histories Used in SHAKE Analysis (m78setl.acc)

(m7S~et2.acc)

(m78Set3.acc)

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 120 of 196 Date: 11/06/02 M78Setl.ACC Time history matched to spectrum:::SetTarget:M78_D005_RVJHW.target 6565 0.0050 0.00730 0.00722 0.00715 0.00708 0.00702 0.00696 0.00690 0.00685 1

0.00679 0.00672 0.00666 0.00659 0.00652 0.00646 0.00639 0.00633 2

0.00626 0.00620 0.00614 0.00608 0.00602 0.00596 0.00591 0.00585 3

0.00579 0.00573 0.00567 0.00561 0.00555 0.00549 0.00542 0.00534 4

0.00526 0.00518 0.00508 0.00498 0.00486 0.00473 0.00458 0.00442 5

0.00423 0.00402 0.00378 0.00353 0.00326 0.00290 0.00245 0.00189 6

0.00119 0.00036 -0.00061 -0.00190 -0.00334 -0.00438 -0.00518 -0.00586 7

-0.00633 -0.00690 -0.00743 -0.00754 -0.00759 -0.00811 -0.00863 -0.00902 8

-0.00915 -0.00842 -0.00741 -0.00656 -0.00560 -0.00453 -0.00348 -0.00232 9

-0.00136 -0.00119 -0.00130 -0.00113 -0.00125 -0.00223 -0.00346 -0.00450 10

-0.00566 -0.00698 -0.00821 -0.00969 -0.01076 -0.01021 -0.00909 -0.00856 11

-0.00744 -0.00458 -0.00139 0.00175 0.00465 0.00607 0.00692 0.00841 12 0.00922 0.00792 0.00608 0.00458 0.00294 0.00141 0.00000 -0.00165 13

-0.00296 -0.00313 -0.00297 -0.00304 -0.00297 -0.00273.-0.00240 -0.00217 14

-0.00183 -0.00108 -0.00027 0.00055 0.00129 0.00164 0.00176 0.00219 15 0.00225 0.00099 -0.00045 -0.00200 -0.00315 -0.00236 -0.00105 -0.00010 16 0.00100 0.00204 0.00273 0.00410 0.00451 0.00129 -0.00262 -0.00644 17 00974 -0.00990 -0.00901 -0.00912 -0.00836 -0.00540 -0.00232 0.00132 18 0.00376 0.00096 -0.00314 -0.00648 -0.00997 -0.01226 -0.01385 -0.01649 19

-0.01779 -0.01442 -0.00991 -0.00603 -0.00204 0.00089 0.00340 0.00643 20 0.00887 0.00957 0.00972 0.01033 0.01055 0.00979 0.00879 0.00792 21 0.00703 0.00633 0.00584 0.00500 0.00463 0.00598 0.00777 0.00929 22 0.01089 0.01217 0.01326 0.01464 0.01564 0.01530 0.01459 0.01416 23 0.01353 0.01252 0.01141 0.01037 0.00925 0.00790 0.00633 0.00511 24 0.00341 -0.00005 -0.00400 -0.00761 -0.01137 -0.01520 -0.01860 -0.02290 25

-0.02585 -0.02372 -0.02015 -0.01768 -0.01450 -0.01032 -0.00627 -0.00154 26 0.00202 0.00094 -0.00131 -0.00287 -0.00459 -0.00542 -0.00562 -0.00681 27

-0.00671 -0.00216 0.00346 0.00857 0.01358 0.01683 0.01900 0.02275 28 0.02447 0.01916 0.01213 0.00603 -0.00017 -0.00456 -0.00783 -0.01274 29

-0.01560 -0.01138 -0.00560 -0.00042 0.00437 0.00539 0.00498 0.00618 30 0.00568 0.00007 -0.00658 -0.01302 -0.01884 -0.02069 -0.02114 -0.02304 31

-0.02351 -0.01996 -0.01554 -0.01140 -0.00756 -0.00605 -0.00541 -0.00386 32

-0.00319 -0.00510 -0.00739 -0.00984 -0.01161 -0.01000 -0.00746 -0.00561 33

-0.00337 -0.00080 0.00150 0.00449 0.00643 0.00428 0.00128 -0.00145 34

-0.00386 -0.00367 -0.00275 -0.00245 -0.00168 -0.00005 0.00174 0.00355 35 0.00519 0.00593 0.00649 0.00712 0.00776 0.00874 0.00953 0.01080 36 0.01129 0.00861 0.00505 0.00217 -0.00116 -0.00521 -0.00921 -0.01360 37

-0.01726 -0.01795 -0.01763 -0.01828 -0.01802 -0.01524 -0.01187 -0.00877 38

-0.00570 -0.00353 -0.00164 0.00051 0.00244 0.00383 0.00507 0.00642 39 0.00768 0.00876 0.00961 0.01087 0.01156 0.01008 0.00805 0.00636 40 0.00457 0.00306 0.00191 0.00014 -0.00079 0.00132 0.00408 0.00663 41 0.00894 0.00933 0.00898 0.00948 0.00908 0.00593 0.00235 -0.00135 42

-0.00438 -0.00402 -0.00272 -0.00212 -0.00109 0.00042 0.00188 0.00366 43 0.00491 0.00398 0.00268 0.00138 0.00044 0.00156 0.00304 0.00452 44 0.00560 0.00447 0.00249 0.00145 -0.00054 -0.00546 -0.01052 -0.01636 45

-0.02051 -0.01733 -0.01215 -0.00842 -0.00386 0.00140 0.00626 0.01225 46 0.01646 0.01379 0.00938 0.00606 0.00232 -0.00073 -0.00347 -0.00668 47

-0.00930 -0.01009 -0.01023 -0.01101 -0.01114 -0.00940 -0.00703 -0.00526 48

-0.00295 0.00085 0.00475 0.00898 0.01244 0.01252 0.01163 0.01151 49 0.01083 0.00919 0.00740 0.00552 0.00392 0.00366 0.00374 0.00360 50 0.00353 0.00328 0.00292 0.00273 0.00233 0.00122 0.00013 -0.00126 51

-0.00209 -0.00053 0.00181 0.00340 0.00563 0.00950 0.01337 0.01783 52 0.02109 0.01925 0.01590 0.01378 0.01073 0.00587 0.00090 -0.00455 53

-0.00899 -0.00903 -0.00782 -0.00760 -0.00670 -0.00470 -0.00248 -0.00027 54 0.00176 0.00276 0.00351 0.00441 0.00524 0.00624 0.00716 0.00826 55 0.00906 0.00858 0.00789 0.00718 0.00670 0.00750 0.00854 0.00953 56 0.01034 0.00996 0.00902 0.00881 0.00772 0.00366 -0.00107 -0.00551 57

-0.00985 -0.01282 -0.01513 -0.01836 -0.02044 -0.01865 -0.01561 -0.01370 58

-0.01082 -0.00548 0.00019 0.00609 0.01120 0.01249 0.01256 0.01377 59 0.01395 0.01149 0.00837 0.00561 0.00278 0.00047 -0.00165 -0.00396 60

-0.00608 -0.00774 -0.00921 -0.01088 -0.01234 -0.01312 -0.01380 -0.01444 61

-0.01522 -0.01675 -0.01821 -0.02007 -0.02117 -0.01920 -0.01630 -0.01413 62

-0.01147 -0.00795 -0.00474 -0.00056 0.00206 -0.00152 -0.00666 -0.01082 63

-0.01532 -0.01907 -0.02238 -0.02636 -0.02949 -0.02976 -0.02946 -0.02929 64

-0.02937 -0.03138 -0.03365 -0.03606 -0.03784 -0.03647 -0.03382 -0.03268 65

Caic Number: GEO.HBIP.02.06

-0.02981 -0.02149 0.02944 0.02266

-0.04728 -0.04279 0.02245 0.02759 0.02838 0.01891

-0.03140 -0.02461 0.03675 0.03476 0.01022 0.00972

-0.01726 -0.02146

-0.00535 0.00049 0.02057 0.02266 0.03690 0.03527 0.00165 0.00159 0.03373 0.03286 0.00321 -0.00065

-0.02608 -0.02662

-0.01292 -0.01050 0.02130 0.02581

-0.01894 -0.02830

-0.00598 0.00086 0.01352 0.01131

-0.01568 -0.02213

-0.05009 -0.04643

-0.01323 -0.00736 0.00506 -0.00439

-0.06527 -0.06055

-0.01062 -0.00801 0.01351 0.00969

-0.04303 -0.04219 0.00818 0.01275

-0.00460 -0.00906

-0.01590 -0.01507 0.01093 0.01466

-0.01580 -0.02207

-0.00897 -0.00427 0.00631 0.00700 0.01180 0.01435 0.02767 0.02561 0.02812 0.02868 0.00744 0.00435

-0.02404 -0.02916

-0.01884 -0.00804 0.03696 0.03715 0.04828 0.05219 0.09804 0.10826 0.17133 0.16921 0.12258 0.12345 0.14441 0.14248 0.13441 0.13451 0.12146 0.12137 0.12055 0.11811 0.09723 0.08874 0.00710 -0.00805

-0.12390 -0.13937

-0.24281 -0.25814

-0.35568 -0.36584

-0.39504 -0.38481

-0.28977 -0.28059

-0.26633 -0.27252

-0.26487 -0.24672

-0.11787 -0.10305

-0.03840 -0.03861

-0.05232 -0.04269 0.16951 0.22755 0.30595 0.25323 0.32673 0.36371 0.34402 0.34249 0.36716 0.36669 0.34239 0.32827 0.19074 0.16962 0.05518 0.04911 0.00727 -0.00275

-0.07632 -0.07883

-0.01186 -0.00283 0.00605 0.01272 0.00517 -0.00385

-0.03441 -0.02903 0.03091 0.03606 0.00823 -0.00210

-0.01506 -0.00741 0.03026 0.02742 0.00946 0.00963

-0.02441 -0.02919 0.00576 0.01187 0.02506 0.02721 0.03249 0.03088 0.00355 0.00351 0.02985 0.02860

-0.00408 -0.00781

-0.02623 -0.02680

-0.00805 -0.00597 0.02870 0.03433

-0.03517 -0.04561 0.00606 0.01313 0.00879 0.00669

-0.02865 -0.03548

-0.04145 -0.03732

-0.00169 0.00475

-0.01556 -0.02582

-0.05297 -0.04735

-0.00635 -0.00426 0.00373 -0.00033

-0.03839 -0.03733 0.01520 0.02005

-0.01257 -0.01724

-O.01402 -0.01356 0.01700 0.02147

-0.02660 -0.03355

-0.00054 0.00432 0.00795 0.00872 0.01726 0.02004 0.02313 0.02045 0.02841 0.02923 0.00166 -0.00112

-0.03360 -0.03948 0.00323 0.01501 0.03697 0.03672 0.05658 0.06030 0.11882 0.12935 0.16438 0.16184 0.12668 0.12817 0.13946 0.13690 0.13439 0.13471 0.12197 0.12211 0.11525 0.11265 0.07879 0.07016

-0.02373 -0.03888

-0.15432 -0.16965

-0.27352 -0.28905

-0.37487 -0.38538

-0.37199 -0.36108

-0.27340 -0.26382

-0.27872 -0.28601

-0.22612 -0.20682

-0.08932 -0.07409

-0.04030 -0.04080

-0.02825 -0.01980 0.28345 0.34826 0.20192 0.13878 0.39102 0.43092 0.34764 0.34786 0.36492 0.36420 0.31162 0.29720 0.14929 0.12765 0.04451 0.03896

-0.01362 -0.02400

-0.07935 -0.08147

-0.02158

0. 03938

-0. 01186

0. 00122
0. 02380 0.00871

-0.03166 0.01690 0.02944 0.02807 0.00529

0. 02598

-0.01141

-0.02644

-0.00318

0. 03616

-0.05156 0.01827 0.00406

-0.04154

-0.03271 0.00987

-0.03606

-0.04063

-0.00208

-0.00592

-0.03381 0.02231

-0.02063

-0.01214 0.02310

-0.03755 0.00796 0.00954 0.02266 0.01854 0.02875

-0.00415

-0.04315 0.02536 0.03692 0.06490 0.13956 0.15748 0.13068 0.13448 0.13437 0.12237 0.10988 0.06035

-0. 05453

-0.18471

-0.30418

-0.39391

-0.34879

-0.25682

-0.29093

-0.18720

-0.06076

-0.04211

-0.00402 0.39741 0.09699 0.45601 0.35093 0.36244 0.28071 0.10769 0.03361

-0.03465

-0.08231 0.01265

-0.01500

-0.01084 0.03756

-0. 01769 0.01042

0. 02031 0.00278

-0.02609 0.01827 0.03147 0.02170 0.01206 0.02061

-0.01517

-0.02336 0.00261 0.02403

-0.04202 0.01784

-0.00058

-0.04433

-0.02794 0.00964

-0.04411

-0.03309 0.00188

-0.01510

-0.02394 0.01655

-0.01996

-0.00679 0.01457

-0.03160 0.00799 0.01007 0.02418 0.02052 0.02390

-0.00890

-0.03834 0.02920 0.03943 0.07270 0.14809 0.14894 0.13417 0.13421 0.13137 0.12205 0.10694 0.04749

-0.07176

-0.19929

-0.31740

-0.39552

-0.33420

-0.25805

-0.28615

-0.16957

-0.05411

-0.04490 0.03560 0.38382 0.14390 0.43344 0.35496 0.35814 0.25892 0.09360 0.02735

-0.04532

-0.08054 0.01771

-0.02555 0.00038

0. 03387

-0. 02161

0. 01894 0.01708

-0. 00431

-0. 01848 0.01876 0.03320

0. 01488 0.01952
0. 01465

-0. 01874

-0. 01969

0. 00913 0.00854

-0.02877

0. 01589

-0.00585

-0.04584

-0. 02300

0. 00741

-0.05067

-0.02571 0.00573

-0.02449

-0.01283

0. 00886

-0.01828

-0. 00054 0.00363

-0.02324 0.00716 0.01069 0.02516

0. 02337 0.01811

-0.01414

-0.03096 0.03113 0.04261 0.08148 0.15545 0.14008 0.13752 0.13449 0.12794 0.12146

-0.10358 0.03374

-0.08924 -

-0.21380 -

-0.32998 -

-0.39455 -

-0.31936 -

-0.26171 -

-0.27795 -

-0.15259 -

-0.04959

-0.04732 0.08294 0.35126 0.21231 0.40039 0.35906 0.35252 0.23581 0.08155

0. 02054

-0.05543

-0.07735 Rev Number: 0 Sheet Number: 121 of 196 Date: 11/06/02 0.02514 66

-0.03814 67 0.01200 68 0.03208 69

-0.02802 70 0.02910 71 0.01329 72

-0.01085 73

-0.01213 74 0.01967 75 0.03547 76 0.00763 77 0.02737 78 0.00881 79

-0.02275 80

-0.01629 81 0.01529 82

-0.00519 83

-0.01744 84 0.01502 85

-0.01052 86

-0.04875 87

-0.01823 88 0.00739 89

-0.05946 90

-0.01762 91 0.01043 92

-0.03482 93

-0.00186 94 0.00215 95

-0.01720 96 0.00528 97

-0.00610 98

-0.01619 99 0.00674 100 0.01103 101 0.02684 102 0.02580 103 0.01268 104

-0.01900 105

-0.02577 106 0.03462 107 0.04523 108 0.08941 109 0.16463 110 0.13036 111 0.14157 112 0.13434 113 0.12445 114 0.12126 115 0.10101 116 0.02073 117

-0.10674 118

-0.22822 119

-0.34320 120

-0.39626 121

-0.30400 122

-0.26328 123

-0.27313 124

-0.13485 125

-0.04307 126

-0.05116 127 0.12365 128 0.33440 129 0.26845 130 0.37101 131 0.36367 132 0.34858 133 0.21330 134 0.06734 135 0.01437 136 0.06677 137 0.07599 138

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 122 of 196 Date: 11/06/02

-0.07221 0.03626

-0.07797

-0.11631

-0.04497

-0.08074

-0.16003

-0.08688

-0.09377

-0.10282

-0.11992

-0.20828

-0.05442 0.04414

-0.02329 0.07936

-0.03299

-0.04561

-0.02586

-0.01459 0.08878 0.08345 0.03732 0.23797 0.15669 0.12843

-0.03986

-0.03487

-0.03136 0.03252

-0.03305 0.06878 0.00510

-0.07452

-0.06390 0.01185

-0.07756

-0.05035

-0.10504

-0.09510

-0.08363

-0.08178

-0.02676

-0.00233

-0.11148

-0.11183

-0.04263

-0.03980

-0.08659

-0.11366 0.02176 0.24459 0.20815 0.11138 0.16042 0.09244 0.06396

-0.04711

-0.01104

-0.02332

-0.08984

-0.00733

-0.05848 0.11134 0.07109 0.19022 0.00728 0.00309 0.19132 0.09709

-0.15815

-0.29616

-0.23634

-0. 06018 0.01589

-0.06280

-0.12829

-0.03740

-0. 09350

-0.15610

-0.07726

-0.10213

-0.10222

-0.12569

-0.20674

-0.02638 0.02733

-0.00673 0.06881

-0.03797

-0.04553

-0.02408

-0.00373 0.09506 0.06970 0.06205 0.23930 0.14938 0.10904

-0.04074

-0.04092

-0.01751 0.02100

-0.02213 0.07178

-0.01127

-0.07331

-0.05795 0.00478

-0.07625

-0.05288

-0.10846

-0.09784

-0. 07692

-0.07814

-0.02423

-0.00860

-0.11939

-0.10810

-0.02658

-0.05536

-0.09241

-0.09760 0.04812 0.25095 0.19405 0.11276 0.15949 0.09156 0.04062

-0.04442

-0.00528

-0.03877

-0. 07403

-0. 02133

-0.03477 0.11242 0.07400

0. 19280

-0.02237 0.03834 0.18277 0.07648

-0.20108

-0.27211

-0.22833

-0.04570

-0.01112

-0. 04610

-0.13407

-0. 03558

-0.10542

-0.14922

-0.06978

-0.10912

-0.10320

-0.13261

-0.19917

-0. 00170 0.00847 0.01271 0.05392

-0.04013

-0.04517

-0.02303 0.00949 0.09880 0.05516 0.09149 0.23451 0.14522 0.08536

-0.03723

-0.04755

-0.00299 0.00703

-0.00782 0.07120

-0.02661

-0.07109

-0.05025

-0.00701

-0.07153

-0.05741

-0.10975

-0.10167

-0.07093

-0.07187

-0.02297

-0.01822

-0.12377

-0.10428

-0.01201

-0.06968

-0.10020

-0.07815 0.07704 0.25129 0.17992 0.11720 0.15521 0.09344 0.01513

-0.04033

-0.00041

-0.05490

-0.05527

-0.03804

-0.00684 0.10922 0.08127 0.18737

-0.04488 0.07390 0.16980 0.05298

-0.24092

-0.24709

-0.21502

-0.03294

-0.03533

-0.02622

-0.14708

-0.02771

-0. 11955

-0.14546

-0.05928

-0.11837

-0.10279

-0.13782

-0.19839 0.02785

-0.01087 0.03137 0.04233

-0.04387

-0.04517

-Q.02125 0.02108 0.10565 0.03964 0.11778 0.23516 0.13826 0.06426

-0.03691

-0.05536 0.01224

-0.00606 0.00406 0.07426

-0.04389

-0.06890

-0.01923

-0.05810

-0.01382

-0.15152

-0.02521

-0.13308

-0.13948

-0.05296

-0.12489

-0.10360

-0.14523

-0. 19021 0.05108

-0.02725 0.04893 0.02891

-0.04616

-0.04428

-0.01980 0.03374 0.10971 0.02728 0.14507 0.23083 0.13328 0.04197

-0.03545

-0.06078 0.02534

-0.01823 0.01706 0.07290

-0.05859

-0.06673

-0. 00428

-0.06578

-0.03563

-0.12803

-0.03730

-0.14090

-0.12662

-0.06126

-0.12150

-0.10722

-0.16059

-0.15907 0.05275

-0.02879 0.05817 0.01321

-0.04646

-0.04008

-0.01885 0.04741 0.10456 0.02754 0.16991 0.21363 0.13231 0.02089

-0.03475

-0.05500 0.02883

-0.02338 0.03047 0.05790

-0.06407

-0.06633

-0.04382 -0.03584 -0.02390

-0.01520 -0.02558 -0.03867

-0.06929

-0.06001

-0.11287

-0.10488

-0.06258

-0.06791

-0.02178

-0.02480

-0.13111

-0.10074 0.00604

-0.08749

-0.10745

-0.06052 0.10403 0.25679 0.16526 0.11877 0.15431 0.09415

-0. 01100

_0.03737 0.00593

-0.07192

-0.03610

-0.05417 0.01847 0.10902 0.08482 0.19257

-0.07780 0.11094 0.16125 0.03380

-0.28757

-0.22031

-0.20916

-0.06580 -0.06176

-0.06446 -0.07422

-0.11403 -0.10999

-0.10682 -0.10233

-0.05692 -0.06228

-0.06232 -0.05340

-0.02038 -0.01554

-0.03455 -0.05310

-0.13515 -0.13079

-0.09549 -0.08340 0.01808 0.00700

-0.10121 -0.09890

-0.11418 -0.11527

-0.04228 -0.02647 0.13204 0.16096 0.25762 0.24705 0.15137 0.14064 0.12253 0.13176 0.15015 0.13641 0.09429 0.08810

-0.03385 -0.03950

-0.03367 -0.02811 0.00953 0.00308

-0.08638 -0.08966

-0.01882 -0.01427

-0.06786 -0.06794 0.04345 0.06230 0.10608 0.09754 0.09336 0.11563 0.18695 0.14595

-0.09873 -0.07832 0.14355 0.15833 0.15099 0.13726 0.00994 -0.02984

-0.32420 -0.32258

-0.19975 -0.20496

-0.19772 -0.16904 0.00829 0.02618

-0.06784 -0.07586

-0.06534 -0.09103

-0.09846 -0.07053

-0.05309 -0.06651

-0.14639 -0.15463

-0.11237 -0.09941

-0.07329 -0.08321

-0.11500 -0.10864

-0.11166 -0.11547

-0.17684 -0.19424

-0.12228 -0.08851 0.04758 0.04840

-0.02523 -0.02668 0.06393 0.07409

-0.00222 -0.01881

-0.04618 -0.04596

-0.03520 -0.03033

-0.01729 -0.01705 0.06091 0.07562 0.09646 0.09110 0.03261 0.03190 0.19221 0.21781 0.19396 0.17445 0.13096 0.13170 0.00149 -0.02150

-0.03490 -0.03405

-0.04585 -0.03980 0.02879 0.03257

-0.02559 -0.03131 0.04324 0.05722 0.03929 0.02264

-0.06672 -0.07158

-0.06587 -0.06547

-0.01228 0.00182

-0.05142 -0.06608

-0.05803 -0.05342

-0.08483 -0.09555

-0.10511 -0.09948

-0.09588 -0.09017

-0.06964 -0.07644

-0.04418 -0.03481

-0.01077 -0.00541

-0.07312 -0.09332

-0.12428 -0.11816

-0.06911 -0.05645

-0.01034 -0.02401

-0.09337 -0.08945

-0.11381 -0.11579

-0.01044 0.00458 0.18850 0.21905 0.23327 0.22130 0.13153 0.12003 0.14162 0.15207 0.12129 0.10563 0.07902 0.07358

-0.04034 -0.04511

-0.02209 -0.01661

-0.00666 -0.01374

-0.08858 -0.09166

-0.01410 -0.00830

-0.06286 -0.06367 0.07816 0.09697 0.08835 0.07847 0.14044 0.16720 0.09684 0.05161

-0.04668 -0.02436 0.16694 0.18209 0.12275 0.11069

-0.07407 -0.11540

-0.30972 -0.30627

-0.21621 -0.22702

-0.13736 -0.10637 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211

Caic Number. GEO.HBE?.02.06

-0.07806

-0.02641

-0.03943

-0.09332 0.01596

-0.04068

-0.06771 0.07682 0.14318 0.04371

-0.05189 0.06329 0.28325 0.12127 0.12879 0.05427 0.12530

-0.01356 0.02194 0.06918 0.04109

-0.06827 0.03222 0.05132

-0.12992

-0.22359 0.00915

-0.27090

-0.12639 0.23705

-0.29973 0.03970 0.04355 0.32903 0.07693 0.03987 0.28865

-0.28680

-0.10701 0.34869 0.19953

-0.27468

-0.43739 0.10641 0.19299 0.30232

-0.56035

-0.44418

-0.28354 0.00960 0.11975 0.82565 0.59804 0.50643

-0.10773

-0.39742

-0.27486

-0.26759 0.10634

-0.47183

-0.65253 0.03105

-0.10600

-0.13697 0.13495 0.58913 0.10703 0.14891

-0.62059

-0.10923

-0.04606

-0.48253

-0.18062

-0.06528

-0.03617

-0.03782

-0.06292

-0.01795

-0.03333

-0.05266 0.09439 0.12287 0.03525

-0.04722 0.09715 0.26780 0.12314 0.11662 0.05870 0.10505 0.00176 0.01225 0.09027 0.01240

-0.05822 0.03445 0.04025

-0.15720

-0.18927

-0.00088

-0.30117

-0.05761 0.18457

-0.28329 0.05950 0.05201 0.33983 0.04293 0.06950 0.23887

-0.28840

-0.05144 0.35701 0.15815

-0.33920

-0.34553 0.10909 0.22792 0.22828

-0.60753

-0.38204

-0.28358

-0.02496 0.19482 0.87216 0.59080 0.47515

-0.16406

-0.39132

-0.24134

-0.33470 0.21090

-0.52388

-0.67374 0.10973

-0.10252

-0.18619 0.21658 0'. 57731 0.08040 0.08850

-0.61254

-0.08094

-0.07232

-0.48639

-0.14930 Sheet Ni

-0.05693 -0.04410 -0.03433 -0.03175 -0.03171 -0.02764

-0.04715 -0.05732 -0.06480 -0.06078 -0:05362 -0.04654

-0.03862 -0.03524 -0.03557 -0.04950 -0.06338 -0.08284

-0.02505 0.00858 0.03745 0.03841 0.02899 0.02710

-0.05423 -0.09492 -0.12555 -0.11085 -0.08501 -0.06328

-0.03058 -0.02036 -0.01545 -0.02738 -0.04144 -0.05708

-0.03131 -0.01700 -0.00027 0.02060 0.04159 0.05960 0.11037 0.12656 0.13954 0.14251 0.14107 0.14482 0.09947 0.07828 0.05950 0.05320 0.05031 0.04694 0.02503 0.01596 0.00518 -0.00862 -0.02230 -0.03910

-0.03732 -0.02969 -0.01827 -0.00253 0.01698 0.03789 0.13359 0.17428 0.21255 0.23385 0.24846 0.27059 0.24423 0.22212 0.19788 0.17935 0.16289 0.13961 0.13006 0.13262 0.13551 0.13640 0.13510 0.13361 0.10224 0.08625 0.07097 0.06369 0.05955 0.05503 0.06646 0.07902 0.09264 0.09956 0.10426 0.11810 0.07862 0.05402 0.02974 0.01835 0.01139 -0.00442 0.02122 0.04184 0.05860 0.04942 0.03484 0.02901 0.00500 -0.00485 -0.00848 0.01157 0.03684 0.05277 0.10737 0.12004 0.12452 0.11026 0.08817 0.06645

-0.01548 -0.04173 -0.06288 -0.07297 -0.07624 -0.07503

-0.04495 -0.02739 -0.00961 0.00333 0.01405 0.02477 0.03441 0.02848 0.02347 0.03203 0.04133 0.04806 0.02410 0.01181 -0.00514 -0.03350 -0.06524 -0.09732

-0.18212 -0.21541 -0.24219 -0.24099 -0.23120 -0.23192

-0.14830 -0.10064 -0.05586 -0.04306 -0.03610 -0.01012

-0.01897 -0.02423 -0.03993 -0.08647 -0.14212 -0.20686

-0.32127 -0.37166 -0.40078 -0.34526 -0.26791 -0.20150 0.01039 0.10193 0.18244 0.20122 0.20270 0.23001 0.11372 0.04201 -0.03605 -0.09928 -0.15677 -0.23801

-0.24444 -0.21994 -0.18288 -0.13043 -0.07501 -0.01385 0.06767 0.08005 0.08370 0.07572 0.06411 0.05134 0.07111 0.09930 0.13670 0.17546 0.21772 0.27684 0.33606 0.33941 0.32623 0.28204 0.22468 0.15069 0.01940 -0.01700 -0.03968 -0.03241 -0.01235 0.01059 0.10094 0.13475 0.16862 0.20046 0.22635 0.26657 0.16874 0.12374 0.06765 -0.02345 -0.11385 -0.20878

-0.27187 -0.30253 -0.31830 -0.25488 -0.18178 -0.14570 0.00324 0.06024 0.11572 0.14974 0.18896 0.27166 0.35349 0.38615 0.40439 0.36926 0.31658 0.26011 0.11729 0.05669 -0.01091 -0.07425 -0.14376 -0.21277

-0.39336 -0.43862 -0.47327 -0.47863 -0.46712 -0.46499

-0.24652 -0.17209 -0.09805 -0.02374 0.03698 0.08082 0.10217 0.09853 0.09428 0.08671 0.09320 0.13565 0.25853 0.31259 0.35827 0.36072 0.34915 0.33956 0.12254 -0.01009 -0.14475 -0.25476 -0.34767 -0.45529

-0.60212 -0.60018 -0.60204 -0.56724 -0.51719 -0.48632

-0.33645 -0.30296 -0.27196 -0.26230 -0.28169 -0.28622

-0.25645 -0.19709 -0.12713 -0.06692 -0.01898 -0.00295

-0.07936 -0.09850 -0.11549 -0.08130 -0.01369 0.05600 0.23512 0.29622 0.40074 0.50591 0.64754 0.74075 0.89095 0.87802 0.89226 0.63052 0.43232 0.61241 0.65004 0.61130 0.50074 0.48453 0.53070 0.52737 0.49856 0.42624 0.26832 0.21194 0.18030 0.04834

-0.19766 -0.27775 -0.36904 -0.43969 -0.47242 -0.44336

-0.39281 -0.41602 -0.44518 -0.41476 -0.37038 -0.33571

-0.25243 -0.25193 -0.23884 -0.24014 -0.23372 -0.22910

-0.38291 -0.39340 -0.37089 -0.30706 -0.20155 -0.05458 0.23604 0.22675 0.17222 0.02213 -0.17069 -0.34526

-0.53350 -0.53899 -0.52279 -0.47818 -0.47722 -0.56220

-0.66980 -0.68664 -0.65931 -0.52682 -0.35022 -0.14995 0.15516 0.20601 0.20408 0.13926 0.06490 -0.02508

-0.07366 -0.06159 -0.05474 -0.06908 -0.09824 -0.11611

-0.21508 -0.18888 -0.13454 -0.07418 -0.00301 0.06709 0.28613 0.32746 0.36989 0.43110 0.48655 0.54384 0.54390 0.51343 0.46455 0.39394 0.31234 0.20495 0.07753 0.07024 0.07890 0.09560 0.11546 0.14407

-0.00502 -0.10149 -0.21599 -0.34849 -0.46890 -0.56459

-0.56415 -0.52630 -0.46775 -0.34044 -0.21984 -0.15281

-0.06986 -0.04461 -0.02514 -0.06321 -0.09630 -0.07084

-0.11252 -0.14900 -0.20221 -0.26544 -0.33204 -0.41513

-0.46008 -0.43002 -0.38517 -0.32931 -0.27273 -0.22190

-0.12119 -0.10222 -0.07969 -0.03298 0.01016 0.04075 Rev Number: 0 umber: 123 of 196 Date: 11/06/02 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 124 of 196 Date: 11/06/02 0.05485 0.03231 -0.00695 -0.04945 -0.09258 -0.12240 -0.13502 -0.14103 285

-0.11998 -0.04509 0.04599 0.13707 0.21795 0.25565 0.26783 0.27432 286 0.25543 0.19807 0.12872 0.05651 -0.00956 -0.04555 -0.06830 -0.08685 287

-0.09371 -0.09239 -0.08176 -0.05484 -0.02195 -0.00105 0.02280 0.07178 288 0.11362 0.11020 0.09028 0.07741 0.04403 -0.02848 -0.11644 -0.21746 289}

-0.31716 -0.37855 -0.42636 -0.47667 -0.50949 -0.51748 -0.50747 -0.48638 290

-0.45179 -0.40336 -0.34869 -0.30388 -0.25863 -0.19364 -0.13558 -0.09472 291

-0.06780 -0.06403 -0.07019 -0.08397 -0.09561 -0.08271 -0.05719 -0.04884 292

-0.02104 0.07473 0.18380 0.28713 0.38388 0.43630 0.47473 0.53393 293 0.57775 0.57223 0.55889 0.56227 0.57052 0.58403 0.60229 0.64032 294 0.67117 0.65103 0.61671 0.59786 0.56420 0.49654 0.41565 0.32258 295 0.22354 0.14639 0.07331 -0.02528 -0.10810 -0.12631 -0.12561 -0.12518 296

-0.11346 -0.10591 -0.08993 -0.06781 -0.03483 0.02942 0.10513 0.15702 297 0.21775 0.33248 0.44344 0.53347 0.59823 0.59477 0.56722 0.54497 298 0.51555 0.48446 0.45767 0.45325 0.45163 0.41874 0.38410 0.38078 299 0.36821 0.30363 0.23004 0.15397 0.08401 0.06593 0.05774 0.02825 300 0.00361 -0.00462 -0.01117 -0.01692 -0.02424 -0.04867 -0.07326 -0.08483 301

-0.09280 -0.10195 -0.10820 -0.10934 -0.11037 -0.11451 -0.12145 -0.13424 302

-0.15080 -0.16472 -0.18112 -0.20985 -0.23632 -0.24082 -0.23875 -0.24160 303

-0.23548 -0.21186 -0.17802 -0.13522 -0.08434 -0.03363 0.02164 0.08839 304 0.15417 0.20406 0.24677 0.29381 0.32794 0.33111 0.31942 0.30562 305 0.27969 0.23802 0.19129 0.13613 0.08712 0.07210 0.06994 0.05783 306 0.06007 0.09849 0.14706 0.19461 0.24135 0.27256 0.29757 0.32696 307 0.34999 0.35705 0.35882 0.36168 0.36123 0.35777 0.35201 0.35315 308 0.34950 0.32136 0.28986 0.26816 0.24772 0.22805 0.21238 0.19603 309 0.18519 0.19141 0.19845 0.20806 0.20793 0.16796 0.11426 0.06493 310 0.00600 -0.06452 -0.13902 -0.22118 -0.29868 -0.34646 -0.38196 -0.43027 311

-0.46281 -0.44509 -0.40777 -0.39416 -0.35692 -0.24149 -0.10852 0.01440 312 0.13698 0.23411 0.31880 0.42128 0.50189 0.50798 0.49220 0.49560 313 0.48500 0.44345 0.39529 0.35586 0.31462 0.26814 0.22196 0.17257 314 0.12615 0.09623 0.06888 0.03683 0.00450 -0.03059 -0.06733 -0.10829 315

-0.14982 -0.18269 -0.21202 -0.25408 -0.28656 -0.27733 -0.25727 -0.24900 316

-0.23469 -0.20729 -0.17927 -0.15119 -0.12881 -0.12835 -0.13453 -0.13424 317

-0.13771 -0.15159 -0.16699 -0.17645 -0.18507 -0.19794 -0.21127 -0.21533 318

-0.22268 -0.25106 -0.28329 -0.30636 -0.33145 -0.36350 -0.39468 -0.42388 319

-0.44791 -0.46034 -0.46544 -0.47078 -0.46875 -0.44930 -0.42314 -0.40521 320

-0.37936 -0.32632 -0.26664 -0.20647 -0.14726 -0.10630 -0.07361 -0.03224 321

-0.00542 -0.01948 -0.04625 -0.07195 -0.09862 -0.11093 -0.11442 -0.12538 322

-0.12148 -0.07399 -0.01363 0.03575 0.09049 0.15770 0.22379 0.28830 323 0.34619 0.38123 0.40994 0.44623 0.47856 0.49876 0.51494 0.53200 324 0.54164 0.53816 0.52545 0.51565 0.49742 0.45293 0.40489 0.37014 325 0.33420 0.28610 0.23223 0.17474 0.10839 0.03477 -0.04365 -0.12395 326

-0.19984 -0.26526 -0.32154 -0.37852 -0.43003 -0.46378 -0.49700 -0.54722 327

-0.59236 -0.60667 -0.60734 -0.61195 -0.59837 -0.54850 -0.48788 -0.43748 328

-0.38539 -0.32279 -0.25865 -0.19476 -0.12607 -0.05648 0.01330 0.09711 329 0.16631 0.17857 0.17065 0.18418 0.18461 0.13867 0.08967 0.05161 330 0.01613 0.00018 -0.01630 -0.05306 -0.08393 -0.08043 -0.06008 -0.02838 331 0.01107 0.03256 0.03750 0.02465 -0.01667 -0.08140 -0.15289 -0.22357 332

-0.26439 -0.24278 -0.19283 -0.14112 -0.10452 -0.11265 -0.15794 -0.23786 333

-0.31686 -0.33477 -0.29843 -0.24035 -0.12320 0.08246 0.28575 0.45972 334 0.56629 0.52938 0.45238 0.43755 0.42627 0.35576 0.29046 0.24203 335 0.18343 0.14130 0.08641 -0.00458 -0.08216 -0.09955 -0.08436 -0.06256 336

-0.02528 0.02032 0.05353 0.06720 0.06193 0.03852 0.01356 -0.00713 337

-0.01532 0.00155 0.02498 0.03280 0.03971 0.06581 0.09399 0.12815 338 0.16588 0.18081 0.19300 0.22070 0.23295 0.20243 0.15413 0.11268 339 0.06768

,0.01424

-0.03047 -0.05693 -0.07841 -0.10679 -0.14091 -0.19140 340

-0.24497 -0.27037 -0.28615 -0.30856 -0.31306 -0.28286 -0.23960 -0.20641 341

-0.17238 -0.12575 -0.08301 -0.05697 -0.02821 0.02155 0.07963 0.14675 342 0.21590 0.26239 0.30085 0.34789 0.38277 0.38756 0.38386 0.38786 343 0.39210 0.39481 0.40115 0.41362 0.42869 0.44331.0.45783 0.46895 344 0.47848 0.49071 0.49848 0.50662 0.50473 0.47094 0.42417 0.38876 345 0.33896 0.24787 0.14783 0.04124 -0.05813 -0.10547 -0.13525 -0.18806 346

-0.21816 -0.17992 -0.12314 -0.07207 -0.01801 0.01922 0.04960 0.09267 347 0.12390 0.11326 0.09029 0.08433 0.06773 0.01600 -0.04274 -0.09554 348

-0.14753 -0.18865 -0.22426 -0.26639 -0.29990 -0.30553 -0.30667 -0.31468 349

-0.32371 -0.33940 -0.35701 -0.38096 -0.39809 -0.38407 -0.35799 -0.34710 350

-0.32175 -0.24846 -0.16682 -0.08698 -0.01395 0.01760 0.03518 0.07386 351 0.09620 0.06221 0.01683 -0.02165 -0.05700 -0.06520 -0.06291 -0.06768 352

-0.06174 -0.03160 0.00359 0.04064 0.07128 0.07116 0.05970 0.05526 353 0.04136 0.00655 -0.03266 -0.07350 -0.11122 -0.12792 -0.13874 -0.16155 354

-0.17803 -0.16981 -0.15743 -0.14741 -0.13977 -0.14933 -0.16524 -0.17246 355

-0.18824 -0.23116 -0.28024 -0.32493 -0.36917 -0.40093 -0.42698 -0.45593 356

-0.47510 -0.46792 -0.45117 -0.44046 -0.42189 -0.38357 -0.33915 -0.29804 357

Caic Number GEO.HBIP.02.06

-0.25322 0.21046 0.44988 0.09892

-0.11993

-0.02593

-0.12162

-0.14052

-0.26727 0.07929 0.20202

-0.09567 0.15172 0.05539

-0.04104

-0.20310

-0.28607

-0.17366

-0.12327 0.25777 0.17983

-0.11438 0.02151 0.21359 0.19562 0.01753 0.10342 0.00436

-0.18675

-0.11889

-0.06766 0.09638 0.20447 0.15639

-0.01884

-0.21930 0.09069

-0.03840

-0.03665 0.03162 0.18417 0.15728 0.12301

-0.11440

-0.32386

-0.28815

-0.03192

-0.13057 0.02387 0.04182

-0.06773 0.01433 0.00793

-0.08682

-0.12422 0.06770

-0.05736

-0.00766 0.01951 0.17384 0.21300 0.04809

-0.07078

-0.19159

-0.07623

-0.07242

-0.06606

-0.16464

-0.11475

-0.12153

-0.03986-

-0.05864

-0.05767-

-0.20177 -0.14771 -0.09745 -0.0445C 0.26761 0.42601 0.04105

-0.10475

-0.02495

-0.13375

-0.15256

-0.24938 0.12241 0.15590

-0.06102 0.13239 0.06558

-0.07579

-0.20901

-0.28841

-0.16072

-0.08682 0.28093 0.13812

-0.13440

0. 06854 0.21739 0.17093 0.02302 0.10296

-0.02512

-0.19239

-0.09859

-0.05769 0.11350 0.20463 0.14352

-0.05329

-0.19879 0.10805

-0.06840

-0.01324 0.04222 0.18947 0.15500 0.09599

-0.14278

-0.32343

-0.26637

-0.03691

-0.11091 0.02558 0.03824

-0.06948 0.00486 0.02877

-0.11946

-0.10023 0.06393

-0.04971

-0.01608 0.03588 0.19694 0.18648 0.03694

-0.08972

-0.18507

-0.06980

-0.07247

-0.07589

-0.16045

-0.12117

-0.10863

-0.04168

-0.05497

-0.04359 0.32014 0.37763 0.39361 0.36933

-0.01250 -0.07298

-0.08729 -0.07014

-0.02694 -0.02574

-0.14202 -0.15467

-0.16922 -0.18098

-0.22030 -0.20135 0.15782 0.20217 0.10271 0.05121

-0.01409 0.02660 0.10538 0.08122 0.07519 0.08870

-0.10870 -0.14626

-0.21565 -0.22041

-0.28579 -0.28838

-0.15226 -0.13962

-0.04127 -0.00375 0.29309 0.31732 0.09639 0.05397

-0.14718 -0.17045 0.11150 0.16131 0.22101 0.22506 0.14284 0.11605 0.03426 0.04136 0.09812 0.09820

-0.05536 -0.08599

-0.19365 -0.19984

-0.08042 -0.05820

-0.04262 -0.03262 0.12770 0.14417 0.20171 0.20156 0.12915 0.11719

-0.08768 -0.12373

-0.16808 -0.14665 0.11345 0.13205

-0.09115 -0.12388 0.00702 0.03235 0.05756 0.06850 0.18929 0.19387 0.15424 0.15262 0.06440 0.03570

-0.17071 -0.19907

-0.31743 -0.31506

-0.23952 -0.21774

-0.05276 -0.06097

-0.08388 -0.06109 0.02457 0.02501 0.03158 0.02880

-0.06499 -0.06656

-0.00980 -0.02315 0.04745 0.07363

-0.14587 -0.18123

-0.07557 -0.05117 0.05259 0.04786

-0.03536 -0.02467

-0.02510 -0.03600 0.05269 0.06887 0.21806 0.24362 0.15792 0.12927 0.02579 0.01546

-0.10836 -0.12778

-0.17368 -0.16658

-0.06712 -0.06116

-0.07148 -0.07130

-0.08853 -0.09896

-0.15214 -0.14662

-0.12966 -0.13802

-0.09456 -0.08063

-0.04543 -0.04799

-0.05072 -0.04602

-0.02510 -0.00998 0.42510 0.33700

-0.12172

-0.05434

-0.02959

-0.16299

-0.19526

-0.17164 0.23535 0.00231 0.06730 0.05906 0.09382

-0.17787

-0.22726

-0.28429

-0.13035 0.03937 0.32810 0.01342

-0.17923 0.20179 0.22725 0.08973

0. 05110 0.09331

-0.11468

-0.20034

-0.04163

-0.01790 0.15896 0.19884 0.10175

-0.15642

-0.11712 0.13654

-0.14422 0'.05136 0.08341 0.19454 0.15063 0.00553

-0.22672

-0.31071

-0.19131

-0.07338

-0.03749 0.02545 0.02172

-0.06274

-0.03390 0.09717

-0.20516

-0.02682 0.03773

-0.01363

-0.04254 0.08608 0.26222 0.10277 0.00366

-0.14579

-0.15594

-0.05792

-0.07059

-0.11074

-0.13979

-0.14455

-0.06759

-0.05093

-0.04267 0.00713 0.01980 0.08587 0.43845 0.44010 0.28013 0.21714

-0.12839 -0.12250

-0.04566 -0.03946

-0.05008 -0.07442

-0.15888 -0.15265

-0.21471 -0.23265

-0.11215 -0.04614 0.23351 0.21939

-0.02681 -0.04625 0.09181 0.10902 0.05557 0.05789 0.06496 0.02696

-0.18701 -0.19030

-0.24174 -0.25731

-0.25910 -0.22942

-0.12869 -0.12653 0.09388 0.14912 0.29661 0.25390

-0.02016 -0.05118

-0.13571 -0.07885 0.20917 0.20802 0.22120 0.21173 0.07002 0.05374 0.06409 0.07705 0.07317 0.04858

-0.13439 -0.15092

-0.18238 -0.15959

-0.04606 -0.05471 0.00944 0.03922 0.17116 0.18183 0.18921 0.17774 0.07343 0.04142

-0.17525 -0.18790

-0.06662 -0.01311 0.09791 0.04895

-0.12267 -0.09043 0.04860 0.04131 0.10798 0.13370 0.18620 0.17609 0.14504 0.13698

-0.02445 -0.05432-

-0.25227 -0.27540-

-0.30584 -0.29961-

-0.15143 -0.11155-

-0.08839 -0.10155-

-0.02083 -0.00697 0.02932 0.03364 0.00040 -0.02308-

-0.04421 -0.02423-

-0.02613 -0.01256-0.04975 -0.00014-

-0.19016 -0.16475-

-0.00212 0.02053 0.01447 -0.00968-

-0.01079 -0.01086-

-0.02954 -0.01151 0.10743 0.13007 0.25387 0.23749 0.08752 0.07546

-0.01418 -0.03364-

-0.15859 -0.16872-

-0.13661 -0.11607-

-0.06086 -0.06515-

-0.06918 -0.06837-

-0.12462 -0.13769-

-0.13306 -0.12736-

-0.14039 -0.13294-

-0.05968 -0.05377-

-0.05317 -0.05474-

-0.04623 -0.05019-0.02673 0.04570 Rev Number: 0 Sheet Number 125 of 196 Date: 11/06/02 0.14873 358 0.44990 359 0.15864 360

-0.12462 361

-0.03160 362

-0.09859 363

-0.14505 364

-0.25409 365 0.01779 366 0.21643 367

-0.07864 368 0.13579 369 0.05458 370

-0.00553 371

-0.19760 372

-0.27290 373

-0.20060 374

-0.12863 375 0.20676 376 0.21890 377

-0.08450 378

-0.03025 379 0.21198 380 0.20595 381 0.03262 382 0.09171 383 0.02783 384

-0.17063 385

-0.13987 386

-0.06229 387 0.06867 388 0.19450 389 0.16754 390 0.01231 391

-0.20833 392 0.04210 393 0.00521 394

-0.06467 395 0.03547 396 0.16090 397 0.16614 398 0.13248 399

-0.08458 400

-0.30252 401

-0.29573 402

-0.06701 403

-0.11998 404 0.01037 405 0.03845 406

-0.04729 407

-0.00214 408 0.00427 409

-0.04276 410 0.14640 411 0.04730 412 0.03671 413 0.00773 414 0.00312 415 0.15166 416 0.22790 417 0.06101 418 0.05191 419 0.18242 420 0.09487 421 0.06902 422 0.06596 423 0.15316 424 0.11954 425 0.12852 426 0.04559 427 0.05736 428 0.05571 429 0.06677 430

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 126 of 196 Date: 11/06/02 0.08435 0.15684 0.18202 0.04517 0.12919 0.02398

-0.02236 0.13115 0.11375 0.07489

-0.09668

-0.03810

-0.13253 0.16362 0.03887 0.16357 0.02640

-0.06979

-0.23926

-0.03075 0.03758

-0.00819 0.12131

-0.00140 0.02578

-0.00341 0.07307 0.01433

-0.05580

-0.16026

-0.16199 0.00210 0.11718 0.07712 0.17475 0.18869 0.19358 0.13117 0.10943

-0.00444 0.03379 0.06801 0.14632 0.11841 0.05089 0.01746

-0.03764

-0.18035

-0.13434

-0.08428

-0.14574 0.01390

-0.09815 0.04775 0.00856 0.04557

-0.00688 0.04063 0.02431 0.12438 0.00233

-0.06561

-0.12377 0.03308

-0.08225 0.01635

-0.06637 0.06464 0.06438

-0.03806

-0.10655 0.04984 0.06571 0.08803 0.08906 0.09051 0.17199 0.18549 0.20213 0.16645 0.14908 0.13303 0.04446 0.04900 0.04835 3 0.12457 0.11363 0.10795 a0.01274 0.00371 -0.00753

-0.00613 0.01427 0.03165 0.13475 0.13399 0.13678 0.11741 0.12217 0.12780 0.04742 0.01782 -0.01166

-0.09599 -0.09114 -0.08994

-0.05022 -0.06785 -0.08211

-0.09639 -0.05026 -0.01021 0.15278 0.13179 0.11753 0.05183 0.07135 0.08656 0.15929 0.14920 0.14478 0.00427 -0.01520 -0.03821

-0.08891 -0.11210 -0.13223

-0.22566 -0.20297 -0.18781

-0.00571 0.01525 0.04154 0.01914 -0.00027 -0.02151 0.01844 0.04783 0.07757 0.10149 0.07719 0.05452

-0.00295 -0.00242 -0.00388 0.03541 0.04366 0.05528

-0.00731 -0.00656 -0.01118 0.07596 0.07358 0.07623 0.00020 -0.01290 -0.02764

-0.06157 -0.06876 -0.07367

-0.17710 -0.19126 -0.20998

-0.13199 -0.10027 -0.06758 0.01610 0.03123 0.04536 0.11126 0.10108 0.09323 0.08723 0.10025 0.11125 0.18063 0.18447 0.19020 0.18774 0.18717 0.18601 0.19387 0.19270 0.19386 0.11998 0.11090 0.09892 0.10314 0.09330 0.08714

-0.01117 -0.01337 -0.02036 0.04130 0.04681 0.05418 0.07837 0.09054 0.10168 0.14690 0.14537 0.14574 0.10756 0.09610 0.08456 0.05021 0.05011 0.05037 0.01107 0.00511 -0.00112

-0.05919 -0.08336 -0.10659

-0.17451 -0.16474 -0.15713

-0.13394 -0.13336 -0.13409

-0.08430 -0.08814 -0.08817

-0.13292 -0.11325 -0.09909 0.00706 -0.00750 -0.01616

-0.08926 -0.07340 -0.06336 0.05875 0.06474 0.07657

-0.00495 -0.01485 -0.03036 0.05849 0.06692 0.08173

-0.02355 -0.03546 -0.05451 0.05611 0.06664 0.08354 0.02516 0.03171 0.03255 0.12455 0.11799 0.11827

-0.01257 -0.02374 -0.03833

-0.07743 -0.09061 -0.10365-

-0.10312 -0.07759 -0.05480 0.01837 -0.00308 -0.02061

-0.06278 -0.03761 -0.01445

-0.00612 -0.03234 -0.05868

-0.04706 -0.02489 -0.00370 0.07198 0.07748 0.08524 0.04747 0.02897 0.01059 -

-0.04609 -0.05447 -0.06229-

-0.09052 -0.06858 -0.05082-0.04760 0.04104 0.03618 0.08428 0.10297 0.12459 0.09369 0.10812 0.1254 0.21411 0.20860 0.1980 0.11621 0.09796 0.0806 0.05262 0.07086 0.0909 0.09824 O.OaO51 0.0611

-0.01654 -0.01945 -0.0194 0.05068 0.07123 0.0909 0.13692 0.13148 0.1254 0.13048 0.11888 0.1025

-0.03915 -0.05552 -0.0679:

-0.08577 -0.07388 -0.0619

-0.09716 -0.10819 -0.1147 0.03153 0.06696 0.0974!

0.10024 0.08378 0.0696!

0.10363 0.11943 0.1335!

0.13487 0.10956 0.0805!

-0.05698 -0.06143 -0.0634(

-0.15392 -0.17643 -0.1966

-0.16686 -0.13408 -0.0987' 0.06119 0.05864 0.0492!

-0.03805 -0.03397 -0.02291 0.10372 0.11140 0.1123!

0.03309 0.02280 0.0158'

-0.00332 0.00310 0.0113:

0.06167 0.04753 0.02891

-0.01000 0.00911 0.0315, 0.07431 0.06080 0.0443C

-0.04016 -0.04502 -0.0479'

-0.08159 -0.10002 -0.12111

-0.22219 -0.21075 -0.19199

-0.03841 -0.02626 -0.01821 0.06001 0.07501 0.08857 0.08515 0.08210 0.08120 0.12335 0.13635 0.14907 0.19416 0.19340 0.19145 0.18555 0.18733 0.18963 0.19179 0.17797 0.16139 0.09050 0.09408 0.10000 0.07742 0.05773 0.03641

-0.02244 -0.01001 0.00569 0.05997 0.06216 0.06404 0.11290 0.12182 0.12962 0.14439 0.13864 0.13139 D.07385 0.06737 0.06240 0.04937 0.04211 0.03338

-0.00738 -0.01434 -0.02257

-0.12883 -0.14339 -0.15454

-0.14919 -0.14489 -0.14186

-0.13250 -0.12120 -0.10829

-0.09172 -0.10497 -0.11875

-0.08124 -0.05712 -0.03367

-0.02857 -0.04623 -0.06333

-0.04890 -0.02543 -0.00050 0.08180 0.06603 0.04506

-0.03846 -0.02050 0.00373 0.08848 0.06791 0.04061

-0.06430 -0.04180 -0.01166 0.09300 0.07828 0.05858 0.03871 0.05907 0.08163 0.11185 0.08644 0.05705

-0.04995 -0.05451 -0.05787

-0.11532 -0.11926 -0.11949

-0.03174 -0.01371 0.00061

-0.03889 -0.05159 -0.06042 0.00674 0.01208 0.01133

-0.08089 -0.08068 -0.07349 0.01660 0.02971 0.04064 0.09016 0.08534 0.07721

-0.00638 -0.01533 -0.02221

-0.07055 -0.08032 -0.08858

-0.03095 -0.01003 0.00937 0.03239 0.03903 0.04927 0.14019 0.13029 0.11338 6

0.14074 5

0.19158 1

0.06093 2

0.11231 7

0,04199 4 -0.02315 3

0.11295 3

0.11865 5

0.09086 1 -0.08452 5 -0.04746 2 -0.12905 5 0.13596 9

0.05085 9 0.15094 9 0.05341 0 -0.06526 1-0.22197 7-0.06408 9 0.04570 3 -0.01862 9 0.12039 9 0.00593 1 0.01810 1 0.01212 0.05373 D 0.02959

-0.05195 L -0.14060

-0.17957 P -0.00782 0.10519 0.07752 0.16271 0.19018 0.19172 0.14624 0.10555 0.01473 0.02000 0.06518 0.13896 0.12555 0.05589 0.02547

-0.02846

-0.16993

-0.13755

-0.09524

-0.13497

-0.00649

-0.08366 0.02489 0.02700 0.02462 0.01703 0.01455 0.04023 0.10498 0.02889

-0.06104

-0.12459 0.02068

-0.07515 0.01740

-0.07266 0.05350 0.07234

-0.03043

-0.10040 0.03223 0.05585 0.10169 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number-127 of 196 Date: 11/06/02 0.08697 0.06902 0.05225 0.03184 0.01750 0.02675 0.04217 0.05349 504 0.06660 0.07875 0.08951 0.10291 0.11254 0.10865 0.10117 0.09615 505 0.08985 0.08310 0.07610 0.06933 0.06235 0.05433 0.04665 0.03803 506 0.03101 0.03000 0.03059 0.03031 0.02991 0.02716 0.02104 0.02104 507 0.01235 -0.02837 -0.07768 -0.12095 -0.16692 -0.21289 -0.25469 -0.30508 508

-0.34229 -0.33000 -0.30336 -0.28825 -0.26480 -0.22540 -0.18373 -0.14086 509

-0.10253 -0.08557 -0.07419 -0.05908 -0.04583 -0.03231 -0.01903 -0.00535 510 0.00741 0.01613 0.02232 0.03216 0.03735 0.02595 0.01146 -0.00258 511

-0.01423 -0.01161 -0.00421 -0.00144 0.00553 0.02337 0.04218 0.06295 512 0.07867 0.07215 0.05905 0.05129 0.03955 0.02012 0.00016 -0.02155 513

-0.03923 -0.03973 -0.03552 -0.03471 -0.03198 -0.02765 -0.02398 -0.01832 514

-0.01577 -0.02528 -0.03707 -0.04849 -0.05823 -0.05762 -0.05404 -0.05285 515

-0.05008 -0.04491 -0.04033 -0.03365 -0.03063 -0.04188 -0.05651 -0.06926 516

-0.08218 -0.09116 -0.09862 -0.10794 -0.11526 -0.11648 -0.11643 -0.11676 517

-0.11752 -0.12161 -0.12615 -0.13101 -0.13451 -0.13159 -0.12537 -0.12359 518

-0.11636 -0.09055 -0.06042 -0.03241 -0.00491 0.01492 0.03017 0.05202 519 0.06533 0.04894 0.02502 0.00573 -0.01516 -0.03266 -0.04779 -0.06662 520

-0.08055 -0.07752 -0.07027 -0.06553 -0.05996 -0.05671 -0.05357 -0.05090 521

-0.04704 -0.03749 -0.02629 -0.01649 -0.00575 0.00672 0.01860 0.03234 522 0.04285 0.04061 0.03439 0.03176 0.02603 0.01279 -0.00213 -0.01645 523

-0.03012 -0.03927 -0.04567 -0.05601 -0.06119 -0.04851 -0.03085 -0.01683 524

-0.00083 0.01716 0.03341 0.05395 0.06762 0.05499 0.03484 0.02059 525 0.00246 -0.02201 -0.04611 -0.07326 -0.09468 -0.09283 -0.08488 -0.08106 526

-0.07524 -0.06947 -0.06432 -0.05780 -0.05317 -0.05514 -0.05796 -0.06146 527

-0.06272 -0.05303 -0.04052 -0.03003 -0.01848 -0.00670 0.00526 0.01706 528 0.02891 0.04111 0.05263 0.06563 0.07614 0.07724 0.07466 0.07612 529 0.07336 0.05738 0.03949 0.02087 0.00573 0.00788 0.01492 0.01809 530 0.02385 0.03371 0.04369 0.05497 0.06364 0.06145 0.05698 0.05327 531 0.05043 0.05467 0.06125 0.06544 0.07186 0.08407 0.09735 0.11065 532 0.12269 0.12819 0.13081 0.13700 0.13895 0.12691 0.11100 0.09806 533 0.08317 0.06515 0.04636 0.02806 0.00964 -0.00850 -0.02626 -0.04466 534

-0.06186 -0.07482 -0.08504 -0.09919 -0.10814 -0.09853 -0.08417 -0.07291 535

-0.06039 -0.04881 -0.03840 -0.02593 -0.01632 -0.01682 -0.01959 -0.02141 536

-0.02282 -0.01946 -0.01452 -0.01112 -0.00645 0.00122 0.00874 0.01771 537 0.02383 0.01839 0.00919 0.00345 -0.00522 -0.02142 -0.03822 -0.05647 538

-0.07112 -0.06996 -0.06433 -0.06217 -0.05775 -0.04993 -0.04232 -0.03300 539

-0.02679 -0.03314 -0.04242 -0.05023 -0.05789 -0.06075 -0.06173 -0.06500 540

-0.06566 -0.05812 -0.04822 -0.04024 -0.03082 -0.01849 -0.00503 0.00716 541 0.02067 0.03856 0.05736 0.07579 0.09381 0.10890 0.12246 0.13810 542 0.15094 0.15419 0.15395 0.15736 0.15694 0.14485 0.12963 0.11662 543 0.10249 0.08740 0.07307 0.05696 0.04369 0.04112 0.04119 0.03981 544 0.03857 0.03464 0.02872 0.02581 0.01921 -0.00038 -0.02121 -0.04413 545

-0.06129 -0.05250 -0.03507 -0.02603 -0.00944 0.02754 0.06695 0.10860 546 0.14312 0.14448 0.13674 0.13583 0.13071 0.12073 0.11065 0.09885 547 0.09034 0.09515 0.10261 0.10948 0.11475 0.10924 0.10040 0.09477 548 0.08625 0.07071 0.05324 0.03706 0.02041 0.00392 -0.01141 -0.02898 549

-0.04306 -0.04416 -0.04108 -0.04185 -0.03920 -0.02752 -0.01414 -0.00108 550 0.01087 0.01605 0.01961 0.02405 0.02837 0.03481 0.04181 0.04828 551 0.05506 0.06228 0.06924 0.07682 0.08337 0.08576 0.08746 0.08916 552 0.09145 0.09742 0.10346 0.11060 0.11527 0.10930 0.09979 0.09371 553 0.08450 0.06678 0.04794 0.02840 0.01149 0.00717 0.00635 0.00283 554 0.00114 0.00216 0.00388 0.00522 0.00674 0.00828 0.01027 0.01138 555 0.01373 0.02095 0.02883 0.03704 0.04380 0.04346 0.04085 0.04037 556 0.03804 0.03101 0.02348 0.01529 0.00895 0.01099 0.01528 0.01796 557 0.02147 0.02532 0.02862 0.03322 0.03582 0.03094 0.02422 0.01857 558 0.01272 0.00859 0.00530 0.00086 -0.00214 -0.00040 0.00268 0.00476 559 0.00746 0.01093 0.01445 0.01817 0.02141 0.02274 0.02328 0.02473 560 0.02513 0.02213 0.01804 0.01497 0.01098 0.00452 -0.00261 -0.00923 561

-0.01614 -0.02342 -0.03076 -0.03812 -0.04527 -0.05160 -0.05715 -0.06395 562

-0.06896 -0.06751 -0.06427 -0.06231 -0.05969 -0.05647 -0.05392 -0.04985 563

-0.04809 -0.05511 -0.06393 -0.07224 -0.07956 -0.08038 -0.07833 -0.07980 564

-0.07729 -0.06192 -0.04418 -0.02666 -0.01134 -0.00824 -0.00976 -0.00622 565

-0.00798 -0.02574 -0.04678 -0.06685 -0.08538 -0.09315 -0.09731 -0.10504 566

-0.10934 -0.10441 -0.09722 -0.09127 -0.08510 -0.08085 -0.07700 -0.07303 567

-0.06891 -0.06329 -0.05761 -0.05165 -0.04638 -0.04417 -0.04271 -0.04084 568

-0.03899 -0.03627 -0.03274 -0.03055 -0.02660 -0.01626 -0.00465 0.00659 569 0.01714 0.02305 0.02730 0.03327 0.03750 0.03670 0.03498 0.03331 570 0.03242 0.03600 0.04063 0.04467 0.04870 0.05107 0.05253 0.05529 571 0.05639 0.05177 0.04578 0.04056 0.03523 0.03133 0.02786 0.02398 572 0.02051 0.01794 0.01563 0.01288 0.01074 0.01058 0.01049 0.01099 573 0.01017 0.00383 -0.00469 -0.01075 -0.01935 -0.03579 -0.05344 -0.07139 574

-0.08727 -0.09290 -0.09481 -0.10071 -0.10238 -0.09143 -0.07697 -0.06512 575

-0.05175 -0.03623 -0.02107 -0.00447 0.00948 0.01303 0.01343 0.01650 576

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 128 of 196 Date: 11/06/02 0.01740 0.01340 0.00830 0.00368 -0.00084 -0.00362 -0.00616 -0.00860 577

-0.01145 -0.01662 -0.02198 -0.02771 -0.03241 -0.03242 -0.03108 -0.03086 578

-0.02980 -0.02707 -0.02406 -0.02101 -0.01832 -0.01747 -0.01712 -0.01637 579

-0.01595 -0.01603 -0.01670 -0.01641 -0.01743 -0.02330 -0.03015 -0.03672 580

-0.04273 -0.04513 -0.04586 -0.04871 -0.04903 -0.04096 -0.03082 -0.02193 581

-0.01275 -0.00511 0.00177 0.00967 0.01623 0.01851 0.01932 0.02150 582 0.02239 0.01974 0.01624 0.01318 0.01011 0.00799 0.00637 0.00408 583 0.00261 0.00384 0.00569 0.00724 0.00877 0.00938 0.00989 0.01026 584 0.01104 0.01378 0.01719 0.01990 0.02325 0.02845 0.03378 0.03948 585 0.04420 0.04463 0.04337 0.04402 0.04257 0.03455 0.02480 0.01625 586 0.00717 -0.00197 -0.01067 -0.02023 -0.02844 -0.03176 -0.03373 -0.03664 587

-0.03900 -0.04084 -0.04284 -0.04425 -0.04660 -0.05250 -0.05936 -0.06551 588

-0.07198 -0.07850 -0.08457 -0.09159 -0.09706 -0.09670 -0.09425 -0.09397 589

-0.09149 -0.08245 -0.07173 -0.06214 -0.05213 -0.04244 -0.03329 -0.02320 590

-0.01456 -0.01118 -0.00956 -0.00624 -0.00460 -0.00771 -0.01225 -0.01557 591

-0.01986 -0.02648 -0.03343 -0.04048 -0.04693 -0.05051 -0.05329 -0.05663 592

-0.05961 -0.06214 -0.06455 -0.06704 -0.06931 -0.07102 -0.07204 -0.07425 593

-0.07476 -0.06890 -0.06141 -0.05504 -0.04818 -0.04143 -0.03495 -0.02800 594

-0.02175 -0.0l801 -0.01477 -0.01143 -0.00785 -0.00248 0.00323 0.00882 595 0.01415 0.01792 0.02075 0.02490 0.02734 0.02386 0.01893 0.01483 596 0.01064 0.00789 0.00617 0.00288 0.00166 0.00780 0.01556 0.02260 597 0.02933 0.03258 0.03460 0.03790 0.03992 0.03832 0.03600 0.03384 598 0.03208 0.03292 0.03430 0.03550 0.03645 0.03551 0.03389 0.03303 599 0.03140 0.02755 0.02334 0.01908 0.01536 0.01436 0.01442 0.01333 600 0.01352 0.01758 0.02234 0.02707 0.03110 0.03133 0.03014 0.03052 601 0.02926 0.02307 0.01589 0.00894 0.00263 0.00025 -0.00061 -0.00318 602

-0.00389 0.00103 0.00720 0.01286 0.01816 0.02046 0.02123 0.02403 603 0.02437 0.01650 0.00681 -0.00208 -0.01055 -0.01493 -0.01741 -0.02229 604

-0.02432 -0.01707 -0.00771 0.00067 0.00875 0.01286 0.01536 0.01984 605 0.02207 0.01735 0.01095 0.00545 -0.00008 -0.00351 -0.00601 -0.00968 606

-0.01197 -0.00983 -0.00658 -0.00401 -0.00124 0.00091 0.00270 0.00502 607 0.00664 0.00598 0.00471 0.00386 0.00279 0.00157 0.00037 -0.00092 608

-0.00206 -0.00268 -0.00324 -0.00371 -0.00441 -0.00612 -0.00817 -0.00988 609

-0.01188 -0.01461 -0.01739 -0.02033 -0.02286 -0.02368 -0.02387 -0.02473 610

-0.02490 -0.02301 -0.02077 -0.01849 -0.01663 -0.01697 -0.01813 -0.01839 611

-0.01954 -0.02338 -0.02768 -0.03197 -0.03577 -0.03694 -0.03738 -0.03837 612

-0.03901 -0.03926 -0.03967 -0.03958 -0.04031 -0.04421 -0.04896 -0.05308 613

-0.05751 -0.06202 -0.06632 -0.07110 -0.07505 -0.07595 -0.07576 -0.07669 614

-0.07646 -0.07290 -0.06835 -0.06463 -0.06031 -0.05472 -0.04911 -0.04312 615

-0.03802 -0.03658 -0.03655 -0.03500 -0.03505 -0.04009 -0.04611 -0.05185 616

-0.05708 -0.05891 -0.05962 -0.06139 -0.06222 -0.06059 -0.05878 -0.05646 617

-0.05531 -0.05934 -0.06459 -0.06915 -0.07372 -0:07661 -0.07854 -0.08189 618

-0.08334 -0.07817 -0.07110 -0.06559 -0.05895 -0.05003 -0.04056 -0.03143 619

-0.02233 -0.01388 -0.00613 0.00275 0.00992 0.01088 0.00983 0.01063 620 0.00979 0.00465 -0.00122 -0.00710 -0.01216 -0.01287 -0.01226 -0.01279 621

-0.01239 -0.00989 -0.00688 -0.00417 -0.00137 0.00120 0.00373 0.00625 622 0.00879 0.01157 0.01425 0.01717 0.01965 0.02035 0.02043 0.02116 623 0.02121 0.01921 0.01652 0.01452 0.01188 0.00747 0.00271 -0.00193 624

-0.00638 -0.00962 -0.01229 -0.01565 -0.01817 -0.01794 -0.01707 -0.01652 625

-0.01596 -0.01620 -0.01661 -0.01695 -0.01721 -0.01683 -0.01602 -0.01589 626

-0.01484 -0.01050 -0.00525 -0.00073 0.00423 0.00987 0.01541 0.02137 627 0.02648 0.02828 0.02889 0.03071 0.03131 0.02835 0.02457 0.02119 628 0.01789 0.01595 0.01456 0.01255 0.01123 0.01197 0.01327 0.01416 629 0.01530 0.01681 0.01838 0.01996 0.02144 0.02253 0.02343 0.02453 630 0.02542 0.02562 0.02574 0.02577 0.02607 0.02761 0.02951 0.03112 631 0.03290 0.03492 0.03680 0.03903 0.04067 0.04002 0.03869 0.03795 632 0.03674 0.03450 0.03209 0.02966 0.02746 0.02637 0.02556 0.02459 633 0.02367 0.02259 0.02135 0.02041 0.01906 0.01628 0.01310 0.01022 634 0.00721 0.00421 0.00144 -0.00180 -0.00428 -0.00392 -0.00255 -0.00224 635

-0.00086 0.00366 0.00887 0.01378 0.01851 0.02167 0.02426 0.02745 636 0.02998 0.03058 0.03058 0.03111 0.03115 0.02997 0.02827 0.02718 637 0.02543 0.02149 0.01725 0.01285 0.00915 0.00872 0.00939 0.00897 638 0.00958 0.01305 0.01700 0.02098 0.02436 0.02467 0.02402 0.02424 639 0.02372 0.02148 0.01902 0.01639 0.01433 0.01489 0.01621 0.01691 640 0.01804 0.01997 0.02190 0.02409 0.02575 0.02520 0.02418 0.02334 641 0.02264 0.02325 0.02432 0.02490 0.02596 0.02843 0.03115 0.03384 642 0.03629 0.03741 0.03803 0.03918 0.03975 0.03860 0.03690 0.03568 643 0.03409 0.03161 0.02910 0.02635 0.02417 0.02438 0.02546 0.02561 644 0.02670 0.03053 0.03488 0.03913 0.04297 0.04447 0.04507 0.04669 645 0.04716 0.04402 0.03982 0.03652 0.03254 0.02700 0.02100 0.01543 646 0.00956 0.00291 -0.00381 -0.01059 -0.01704 -0.02211 -0.02654 -0.03174 647

-0.03592 -0.03673 -0.03639 -0.03716 -0.03685 -0.03342 -0.02915 -0.02555 648

-0.02152 -0.01675 -0.01182 -0.00699 -0.00222 0.00218 0.00633 0.01081 649

Calc Number: GEO.HBIP.02.06 0.01477 0.01431 0.00231 0.00096 0.01667 0.01636

-0.00562

-0.02094 0.00144 0.02080 0.03068 0.04874 0.05495

0. 04204
0. 01115 0.02037 0.03312 0.04541 0.02632 0.01055 0.00020 0.01398 0.03315 0.03976 0.03421 0.02859 0.01651 0.00816 0.00127 0.01073 0.02251 0.02364 0.00222 0.00593 0.01481 0.02041 0.01355

-0.00674

-0.01766

-0.00737 0.00104 0.00912

-0.01413

-0.00915 0.00872 0.00623

-0.00575

-0.00882

-0.00408

-0.01071

-0.00988

-0.01901

-0.01700

-0.00708

-0.01638

-0.01409

-0.00599

-0.01144

-0.01449

-0.01666

-0.01041

-0.01663

-0.01581

-0.00671

-0.01593

-0.02881

-0.02276

-0.01836

-0.01873

-0.01786

-0.02666

-0.02601

-0.02645 0.01699 0.01155 0.00228 0.00251 0.01783 0.01372

-0. 00777

-0.01987 0.00405 0.02266 0.03277 0.05013 0.05423 0.03855 0.00974 0.02215 0.03662 0.04250 0.02483 0.00751 0.00311 0.01471 0.03574 0.03905 0.03364 0.02659 0.01614 0.00641 0.00240

0. 01149 0.02468 0.02032 0.00180 0.00721 0.01574 0.02013 0.01152

-0.00934

-0.01642

-0.00685 0.00333 0.00653

-0.01501

-0.00663 0.00944 0.00431

-0.00647

-0.00790

-0.00527

-0.00991

-0.01162

-0.01871

-0.01567

-0.00826

-0.01623

-0.01298

-0.00648

-0.01196

-0.01483

-0.01570

-0.01135

-0.01669

-0.01477

-0.00682

-0.01818

-0.02838

-0.02227

-0.01805

-0.01861

-0.01868

-0.02715

-0.02604

-0.02632 0.01850 0.00882 0.00225 0.00452 0.01863 0.01075

-0.00980

-0.01797 0.00631 0.02432 0.03518 0.05125 0.05318 0.03476 0.00923 0.02355 0.04028

0. 03918 0.02332 0.00456 0.00637 0.01576 0.03780 0.03835 0.03308 0.02440 0.01579 0.00477 0.00377 0.01226 0.02658 0.01678 0.00181 0.00848 0.01663 0.01962 0.00929

-0.01171

-0.01488

-0.00641

0. 00561 0.00341

-0.01527

-0.00401 0.00979 0.00228

-0.00710

-0.00681

-0.00670

-0.00896

-0.01351

-0.01828

-0.01410

-0.00991

-0.01584

-0.01172

-0.00727

-0.01242

-0.01518

-0.01451

-0.01258

-0.01665

-0.01355

-0.00733

-0.02039

-0.02761

-0.02186

-0.01786

-0.01838

-0.01972

-0.02738

-0.02620

-0.02618 0.02080 0.00585 0.00228 0.00616 0.01983 0.00802

-0.01189

-0.01688 0.00878 0.02620 0.03733 0.05261 0.05248 0.03127 0.007747 0.02521 0.04417 0.03601 0.02193 0.00128 0.00964 0.01628 0.04048 0.03764 0.03254 0.02224 0.01557 0.00292 0.00499 0.01288 0.02899 0.01328 0.00142 0.00977 0.01755 0.01934 0.00730

-0.01440

-0.01352

-0.00604 0.00809 0.00069

-0.01614

-0.00143 0.01052 0.00025

-0.00782

-0.00577

-0.00804

-0.00798

-0.01540

-0.01790

-0.01268

-0.01128

-0.01561

-0.01056

-0.00784

-0.01293

-0.01551

-0.01344

-0.01366

-0.01668

-0.01248

-0.00741

-0.02269

-0.02709

-0.02142

-0.01754

-0.01821

-0.02055

-0.02786

-0.02627

-0.02601 0.02218 0.00336 0.00223 0.00802

0. 02056 0.00521

-0.01391

-0.01504 0.01113 0.02782 0.03960 0.05372 0.05142 0.02758 0.00731 0.02673 0.04735 0.03300 0.02035

-0.00134 0.01249 0.01749 0.04242 0.03694 0.03195 0.02025 0.01508 0.00142 0.00624 0.01377 0.03060 0.00999 0.00141 0.01100 0.01840 0.01883 0.00508

-0.01662

-0.01212

-0.00547 0.01011

-0.00222

-0.01639 0.00105 0.01082

-0.00163

-0.00842

-0.00484

-0.00928

-0.00725

-0.01708

-0.01754

-0.01126

-0.01269

-0.01531

-0.00940

-0.00853

-0.01338

-00.

1584

-0.01241

-0.01471

-0.01665

-0.01133

-0.00794

-0.02475

-0.02642

-0.02097

-0.01737

-0.01804

-0.02152

-0.02810

-0.02637

-0.02590 0.02061 0.01822 0.00284 0.00284 0.00188 0.00159 0.01019 0.01237 0.01976 0.01845 0.00245 -0.00023

-0.01580 -0.01745

-0.01111 -0.00676 0.01358 0.01600 0.02860 0.02926 0.04193 0.04420 0.05416 0.05435 0.04924 0.04671 0.02341 0.01931 0.01024 0.01389 0.02827 0.02996 0.04735 0.04636 0.03117 0.02966 0.01801 0.01541

-0.00138 -0.00055 0.01313 0.01322 0.02117 0.02538 0.04205 0.04108 0.03625 0.03557 0.03118 0.03026 0.01917 0.01838 0.01348 0.01159 0.00118 0.00135 0.00740 0.00850 0.01582 0.01818 0.02929 0.02709 0.00783 0.00608 0.00241 0.00368 0.01200 0.01292 0.01897 0.01942 0.01761 0.01618 0.00218 -0.00087

-0.01715 -0.01714

-0.01088 -0.00974

-0.00397 -0.00218 0.01019 0.00961

-0.00528 -0.00822

-0.01482 -0.01274 0.00309 0.00492 0.00986 0.00851

-0.00277 -0.00370

-0.00861 -0.00862-

-0.00452 -0.00446 -

-0.00977 -0.00998 -

-0.00772 -0.00858-

-0.01773 -0.01805-

-0.01742 -0.01727 -

-0.01009 -0.00916 -

-0.01371 -0.01454 -

-0.01503 -0.01470 -

-0.00846 -0.00768 -

-0.00926 -0.00999 -

-0.01368 -0.01394 -

-0.01610 -0.01625 -

-0.01180 -0.01141 -

-0.01527 -0.01568 -

-0.01648 -0.01623 -

-0.01013 -0.00900 -

-0.00978 -0.01197 -

-0.02594 -0.02680 -

-0.02551 -0.02458 -

-0.02032 -0.01965 -

-0.01767 -0.01806 -

-0.01795 -0.01795 -

-0.02281 -0.02412 -

-0.02764 -0.02705 -

-0.02640 -0.02641 -

-0.02605 -0.02621 -

Rev Number: 0 Sheet Number: 129 of 196 Date: 11/06/02 0.01646 650 0.00248 651 0.00107 652 0.01463 653 0.01764 654

-0.00300 655

-0.01953 656

-0.00255 657 0.01846 658 0.02984 659 0.04657 660 0.05480 661 0.04454 662 0.01493 663 0.01719 664 0.03132 665 0.04629 666 0.02791 667 0.01307 668

-0.00056 669 0.01365 670 0.02933 671 0.04051 672 0.03488 673 0.02957 674 0.01735 675 0.00992 676 0.00112 677 0.00967 678 0.02031 679 0.02566 680 0.00393 681 0.00476 682 0.01388 683 0.02001 684 0.01497 685

-0.00382 686

-0.01764 687

-0.00847 688

-0.00068 689 0.00971 690

-0.01142 691

-0.01109 692 0.00698 693 0.00751 694

-0.00479 695

-0.00885 696

-0.00409 697

-0.01051 698

-0.00906 699

.0.01866 700

-0.01726 701

-0.00785 702

-0.01560 703 0.01448 704

-0.00667 705

-0.01074 706

-0.01421 707 0.01659 708 0.01072 709 0.01622 710 0.01611 711 0.00770 712 0.01388 713 0.02801 714 0.02362 715 0.01897 716 0.01843 717 0.01780 718 0.02547 719 0.02649 720 0.02645 721 0.02644 722

Calc Number: GEO.HBEP.02.06 Rev Number: 0 Sheet Number: 130 of 196 Date: 11/06/02

-0.02649

-0.01782

-0.01565

-0.02226

-0.02204

-0. 01626

-0.01401

-0.02439

-0. 02178

-0.02358

-0.02129

-0.01915

-0.01361

-0.01146

-0.01160

-0.01582

-0.01300

-0.00590

-0.00583

-0.00703

-0.00928

-0.00481

-0.00401 0.00167

-0.00207

-0.00208

-0.00237

-0.00055

-0.00019 0.00323 0.00582 0.00484 0.00479 0.00444 0.00427

0. 00689 0.00563 0.00404 0.00529 0.00888 0.00929 0.00915 0.00884 0.00900 0.00943 0.01041 0.01141 0.01110 0.01114 0.01119 0.01100 0.01104 0.01146 0.01079 0.01095 0.01121 0.01114 0.01065 0.01956 0.01976 0.01922 0.01874 0.01793 0.01694 0.01601 0.01506 0.01392 0.01254 0.01106 0.00942 0.00772 0.00594 0.00410

-0.02575

-0.01716

-0.01621

-0.02272

-0.02142

-0.01546

-0.01533

-0.02447

-0.02154

-0.02371

-0.02109

-0.01849

-0.01300

-0.01149

-0.01207

-0.01583

-0.01218

-0.00523

-0.00643

-0.00701

-0.00936

-0.00420

-0.00357 0.00165

-0.00238

-0.00205

-0.00219

-0.00052 0.00023 0.00352 0.00587 0.00487 0.00464 0.00442 0.00458 0.00684 0.00545 0.00396 0.00580 0.00903 0.00925 0.00917 0.00877 0.00914 0.00940 0.01069 0.01132 0.01118 0.01107 0.01123 0.01094 0.01114 0.01137 0.01083 0.01094 0.01125 0.01109 0.01053 0.01955 0.01975 0.01916 0.01865 0.01782 0.01682 0.01591 0.01493 0.01376 0.01236 0.01087 0.00921 0.00750 0.00570 0.00388

-0.02478

-0.01668

-0.01692

-0.02301

-0.02076

-0.01474

-0.01690

-0.02428

-0. 02145

-0.02367

-0.02098

-0.01778

-0.01247

-0.01152

-0.01266

-0.01568

-0.01131

-0.00469

-0.00698

-0.00708

-0.00925

-0.00377

-0.00293 0.00138

-0.00253

-0.00207

-0.00196

-0.00055 0.00071 0.00378 0.00583 0.00495 0.00448 0.00438 0.00496 0.00669 0.00528 0.00395 0.00633 0.00913 0.00920 0.00917 0.00872 0.00928 0.00939

0. 01095 0.01121 0.01126 0.01101
0. 01125 0.01089 0.01123 0.01126
0. 01088 0.01094 0.01128 0.01104 0.01041 0.01957 0.01970 0.01911 0.01854 0.01770 0.01669 0.01581 0.01478 0.01359 0.01218 0.01067
0. 00899 0.00729 0.00546 0.00367

-0.02402 -0.02310

-0.01604 -0.01556

-0.01747 -0.01815

-0.02348 -0.02374

-0.02014 -0.01949

-0.01389 -0.01324

-0.01829 -0.01972

-0.02432 -0.02417

-0.02118 -0.02111

-0.02381 -0.02376

-0.02082 -0.02066

-0.01711 -0.01643

-0.01184 -0.01135

-0.01156 -0.01158

-0.01315 -0.01368

-0.01568 -0.01553

-0.01050 -0.00966

-0.00396

-0.00763

-0.00703

-0.00937

-0.00314

-0.00249 0.00134

-0.00282

-0.00204

-0.00177

-0.00054 0.00114 0.00405 0.00587 0.00501 0.00431 0.00436 0.00529 0.00663 0.00512 0.00386 0.00684 0.00928 0.00915 0.00919 0.00864 0.00944 0.00933 0.01124 0.01111 0.01135 0.01093 0.01130 0.01083 0.01133 0.01116 0.01092 0.01092 0.01132 0.01098 0.01027 0.01957.

0.01968 0.01904 0.01844 0.01759 0.01657 0.01571 0.01464 0.01343 0.01200 0.01047 0.00878 0.00707 0.00523 0.00345

-0.00351

-0.00811

-0.00712

-0.00922

-0.00273

-0.00190 0.00110

-0.00298

-0.00205

-0.00156

-0.00054 0.00159 0.00432 0.00584 0.00506 0.00418 0.00433 0.00564 0.00651 0.00494 0.00386 0.00734 0.00938 0.00911 0.00919 0.00860 0.00956 0.00934 0.01147 0.01102 0.01141 0.01089 0.01131 0.01079 0.01141 0.01106 0.01096 0.01092 0.01134 0.01093 0.01019 0.01958 0.01963 0.01898 0.01834 0.01747 0.01644 0.01559 0.01449 0.01326 0.01181 0.01027 0.00856 0.00685 0.00500 0.00324

-0.02179

-0.01551

-0.01917

-0.02340

-0.01869

-0.01330

-0.02096

-0.02361

-0.02167

-0.02319

-0.02031

-0.01571

-0.01132

-0.01157

-0.01424

-0.01496

-0.00871

-0.00398

-0.00791

-0.00763

-0.00820

-0.00300

-0.00100 0.00034

-0.00279

-0.00213

-0.00130

-0.00047 0.00201 0.00471 0.00560 0.00501 0.00422 0.00430 0.00597 0.00630 0.00471 0.00418 0.00775 0.00937 0.00912 0.00911 0.00869 0.00955 0.00959 0.01149 0.01103 0.01136 0.01095 0.01124 0.01085 0.01144 0.01098 0.01096 0.01099 0.01130 0.01086 0.01975 0.01963 0.01954 0.01892 0.01824 0.01734 0.01633 0.01547 0.01436 0.01308 0.01163 0.01006 0.00835 0.00662 0.00477 0.00302

-0.02044

-0. 01561

-0. 02023

-0. 02289

-0. 01786

-0. 01363

-0. 02208

-0.02297

-0.02236

-0.02252

-0.01990

-0.01500

-0.01141

-0.01159

-0.01476

-0.01426

-0.00776

-0.00469

-0.00756

-0.00822

-0.00699

-0.00338

-0. 00009

-0.00051

-0.00253

-0.00221

-0.00105

-0.00036 0.00241 0.00508 0.00533 0.00492 0.00431 0.00430 0.00627 0.00606 0.00448 0.00458 0.00812 0.00934 0.00913 0.00901 0.00880 0.00949 0.00989 0.01144 0.01106 0.01127 0.01104 0.01115 0.01092 0.01144 0.01092 0.01096 0.01107 0.01124 0.01079 0.01972 0.01968 0.01943 0.01887 0.01814 0.01721 0.01623 0.01533 0.01421 0.01290 0.01144 0.00985 0.00814 0.00639 0.00455 0.00280

-0. 01906

-0.01555

-0.02130

-0.02250

-0.01706

-0.01366

-0.02337

-0. 02234

-0.02301

-0.02187

-0. 01956

-0.01429

-0.01142

-0.01154

-0.01535

-0.01367

-0.00680

-0.00522

-0.00729

-0.00879

-0.00587

-0.00376 0.00089

-0.00133

-0.00229

-0.00232

-0.00077

-0.00032 0.00284 0.00549 0.00506 0.00487 0.00438 0.00425 0.00662 0.00584 0.00425 0.00491 0.00853 0.00932

0. 00914 0.00893 0.00889 0.00947 0.01014 0.01145
0. 01108 0.01121 0.01111 0.01108 0.01098 0.01147 0.01085 0.01096 0.01115 0.01120 0.01072 0.01961 0.01973 0.01933 0.01881 0.01804 0.01707 0.01612 0.01520 0.01407 0.01272 0.01125 0.00963 0.00793 0.00617 0.00432 0.00258 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795

0.00236 0.00064

-0.00095

-0.00246

-0.00384

-0.00510

-0.00620

-0.00716

-0.00794

-0.00856

-0.00905

-0.00943

-0.00961

-0.00958

-0.00932

-0.00887

-0.00831

-0.00769

-0.00706

-0.00646

-0.00590

-0.00535

-0.00482

-0.00428

-0.00372

-0.00314 0.00214 0.00043

-0.00114

-0.00264

-0.00401

-0.00524

-0.00633

-0.00726

-0.00803

-0.00863

-0.00910

-0.00946

-0.00962

-0.00956

-0.00927

-0.00881

-0.00823

-0.00761

-0.00699

-0.00639

-0.00583

-0.00529

-0.00475

-0.00421

-0.00365

-0.00307 0.00192 0.00023

-0.00134

-0. 00281

-0.00417

-0.00539

-0.00646

-0.00737

-0.00811

-0.00869

-0.00916

-0.00949

-0.00963

-0.00953

-0.00922

-0.00874

-0. 00816

-0.00753

-0.00691

-0.00632

-0.00576

-0.00522

-0.00469

-0.00414

-0.00358

-0.00299 0.00170 0.00148 0.00003 -0.00017

-0.00153 -0.00172

-0.00299 -0.00316

-0.00433 -0.00449

-0.00553 -0.00567

-0.00658 -0.00670

-0.00747 -0.00757

-0.00819 -0.00827

-0.00875 -0.00882

-0.00921 -0.00926

-0.00952 -0.00955

-0.00963 -0.00962

-0.00950 -0.00947

-0.00917 -0.00911

-0.00867 -0.00860

-0.00808 -0.00800

-0.00745 -0.00737

-0.00683 -0.00676

-0.00625 -0.00618

-0.00569 -0.00562

-0.00515 -0.00509

-0.00462 -0.00455

-0.00407 -0.00400

-0.00351 -0.00343

-0.00292 -0.00284 0.00127

-0.00036

-0.00191

-0.00333

-0.00465

-0.00580

-0.00682

-0.00767

-0.00835

-0.00888

-0.00930

-0.00957

-0.00962

-0.00944

-0.00906

-0.00853

-0.00792

-0.00730

-0.00668

-0.00610

-0.00555

-0.00502

-0.00448

-0.00393

-0.00336

-0.00170 Calc Number: GEO.HBIP.02.06 Rev Number: 0 SheetNumber: 131 of 196 Date: 11/06/02 0.00106 0.00085 796

-0.00056 -0.00075 797

-0.00209 -0.00228 798

-0.00351 -0.00367 799

-0.00480 -0.00495 800

-0.00594 -0.00607 801

-0.00693 -0.00705 802

-0.00776 -0.00785 803

-0.00842 -0.00849 804

-0.00894 -0.00899 805

-0.00935 -0.00939 806

-0.00959 -0.00960 807

-0.00961 -0.00959 808

-0.00940 -0.00936 809

-0.00900 -0.00894 810

-0.00846 -0.00838 811

-0.00784 -0.00777 812

-0.00722 -0.00714 813

-0.00661 -0.00654 814

-0.00603 -0.00597 815

-0.00549 -0.00542 816

-0.00495 -0.00489 817

-0.00442 -0.00435 818

-0.00386 -0.00379 819

-0.00329 -0.00321 820

-0.00206 -0.00243 821

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 132 of 196 Date: 11/06/02 M78Set2.ACC Time history matched to spectrum:::SetTarget:M78_DO05_RV_HW.tazget2 11997 0.0050 0.00019 0.00019 0.00018 0.00018 0.00018 0.00020.

0.00017

-0.00005

-0. 00055

-0.00120

-0.00165

-0.00302

-0.01017

-0.02120

-0.02421

-0.01549

-0.00966

-0.02687

-0.05987

-0.06479

-0.03241 0.00179

-0.00042 0.00412 0.04560 0.08061 0.09853 0.05288

-0.00505 0.00629 0.06655

-0.00212

-0.00002 0.00375 0.01700 0.09060 0.17981 0.19453 0.17325 0.21635 0.15023 0.20777

-0.13388 -

-0.26880 -

-0.19186 -

-0.22400 -

-0.26368 -

-0.26693 -

-0.09649 -

0.09196 0.15673 0.21714 0.15299 0.22026 0.37815 0.16369

-0.28087

-0.48344 0.04177 0.33311 0.52396 0.59997

-0.45323 -

-0.40267 -

-0.33884 -

-0.70841 -

0.00621 0 00936 0 01441 0 02044 0 02709 0 03385 0 03999 24 0.05026 0 05450 0 05901 0 06345 0 06782 0 07217 0 07643 25 0.08442 0 08810 0 09186 0 09519 0 09775 0 09934 0 09958 26 0.09608 0 09240 0 08792 0 08242 0 07557 0 06809 0 06061 27 0.04482 0 03666 0 02871

'O 02086 0 01251 0 00497

-0 00082 28

-0.00722

-0 00794

-0 00739

-0 00599

-0 00459

-0 00220 0 00104 29 0.01473 0 02525 0 03750 0 04966 0 06025 0 06747 0 06963 30 0.05765 0 04496 0 02981 0 01509 0 00358 -0 00368

-0 00515 31 0.00529 0 01370 0 01949 0 02249 0 02130 0 01670 0 00872 32

-0.00659

-0 01100

-0 01205

-0 01051

-0 00673

-0 00214 0 00122 33 0.00459 0 00470 0 00474 0 00510 0 00678 0 00924 0 01290 34 0.02063 0 02488 0 02977 0 03654 0 04651 0 05907 0 07399 35 0.10785 0 12480 0 14055 0 15410 0 16455 0 17221 0 17677 36 0.18300 0 18607 0 19029 0 19425 0 19649 0 19757 0 19664 37 0.19155 0 18803 0 18484 0 18163 0 17785 0 17475 0 17316 38 0.17557 0 17999 0 18679 0 19474 0 20321 0 21065 0 21487 39 0.21410 0 20917 0 20257 0 19408 0 18477 0 17405 0 16237 40 0.13742 0 12750 0 12194 0 12390 0 13578 0 15532 0 18217 41 0.22647 0 23025 0 20988 0 16819 0 10408 0 02688

-0 05528 42 0.19835

-0 24704

-0 27452

-0 28625

-0 28591

-:0 27897 -0 27317 43 0.26990

-0 27257

-0 27505

-0 27363

-0 26399

-0 24711

-0 22100 44 0.16339

-0 14084

-0 13097

-0 13248

-0 14637

-0 1689D

-0 19589 45 0.24854

-0 26828

-0 28189

-0 28892

-0 28994

-0 28531

-0 27585 46 0.25157

-0 24060

-0 23148

-0 22697

-0 22803

-0 23548

-0 24944 47 0.28715

-0 30158

-0 30487

-0 29303

-0 25889

-0 21127

-0 15463 48 0.04757

-0 00649 0 02303 0 04453 0 06274 0 07592 0 08561 49 0.09517 0 09723 0 10017 0 10535 0 11347 0 12519 0 14027 so 0.17342 0 18867 0 20091 0 21111 0 21889 0 22313 0 22253 51 0.20762 0 19565 0 18458 0 17444 0 16537 0 15906 0 15455 52 0.15521 0 16028 0 16833 0 17858 0 19077 0 20247 0 21267 53 0.22240 0 22321 0 22534 0 23399 0 25343 0 28413 0 32823 54 0.42652 0 46191 0 47207 0 45473 0 40991 0 34361 0 25900 55 0.06434

-0 03693

-0 13326

-0 21420

-0 27242

-0 30191

-0 30007 56 0.25468

-0 23426

-0 22701

-0 23920

-0 28161

-0 34248

-0 41747 57 0.51806

-0 51793

-0 47396

-0 39854

-0 29472

-0 17596

-0 06337 58 0.12983 0 20171 0 25853 0 29904 0 32819 0 33990 0 33907 59 0.31849 0 30765 0 30754 0 31822 0 34700 0 39338 0 45692 60 0.58559 0 64451 0 68354 0 70236 0 70393 0 68816 0 66048 61 0.51221 0 41128 0 26885 0 09434

-0 07885

-0 23163

-0 36092 62 0.48240

-0 48085

-0 46041

-0 42263

-0 39988

-0 39706

-0 39615 63 0.41727

-0 41950

-0 39791

-0 34888

-0 33871

-0 32038

-0 32165 64 0.36355

-0 36902

-0 35662

-0 37167

-0 42655

-0 49513

-0 57072 65 0.78161

-0 84568

-0 86432

-0 88108

-0 76270

-0 69390

-0 55416 66 0.00019 0.00019 0.00019 0.00019 0.00018 0.00018 0.00017 0.00017 0.00018 0.00018 0.00020 0.00020 0.00016 0.00014

-0.00010 -0.00015

-0.00063 -0.00071

-0.00127 -0.00134

-0.00171 -0.00178

-0.00349 -0.00407

-0.01157 -0.01301

-0.02239 -0.02344

-0.02352 -0.02254

-0.01447 -0.01344

-0.01055 -0.01215

-0.02877 -0.03100

-0.06507 -0.06926

-0.06100 -0.05710

-0.02760 -0.02267 0.00369 0.00473

-0.00105 -0.00129 0.00621 0.00936 0.05026 0.05450 0.08442 0.08810 0.09608 0.09240 0.04482 0.03666

-0.00722 -0.00794 0.01473 0.02525 0.05765 0.04496 0.00529 0.01370

-0.00659 -0.01100 0.00459 0.00470 0.02063 0.02488 0.10785 0.12480 0.18300 0.18607 0.19155 0.18803 0.17557 0.17999 0.21410 0.20917 0.13742 0.12750 0.22647 0.23025 0.19835 -0.24704 0.26990 -0.27257 0.16339 -0.14084 0.24854 -0.26828 0.25157 -0.24060 0.28715 -0.30158 0.04757 -0.00649 0.09517 0.09723 0.17342 0.18867 0.20762 0.19565 0.15521 0.16028 0.22240 0.22321 0.42652 0.46191 0.06434 -0.03693 0.25468 -0.23426 0.51806 -0.51793 0.12983 0.20171 0.31849 0.30765 0.58559 0.64451 0.51221 0.41128 0.48240 -0.48085 0.41727 -0.41950 0.36355 -0.36902 -

0.78161 -0.84568 0.00019 0.00019 0.00019 0.00019 0.00018 0.00018 0.00017 0.00017 0.00018 0.00019 0.00020 0.00020 0.00012 0.00009

-0.00021 -0.00027

-0.00080 -0.00088

-0.00140 -0.00145

-0.00187 -0.00199

-0.00477 -0.00560

-0.01448 -0.01593

-0.02417 -0.02464

-0.02102 -0.01939

-0.01268 -0.01192

-0.01452 -0.01724

-0.03406 -0.03789

-0.07218 -0.07356

-0.05344 -0.04976

-0.01766 -0.01280 0.00474 0.00408

-0.00109 -0.00056 0.01441 0.02044 0.05901 0.06345 0.09186 0.09519 0.08792 0.08242 0.02871 0.02086

-0.00739 -0.00599 0.03750 0.04966 0.02981 0.01509 0.01949 0.02249

-0.01205 -0.01051 0.00474 0.00510 0.02977 0.03654 0.14055 0.15410 0.19029 0.19425 0.18484 0.18163 0.18679 0.19474 0.20257 0.19408 0.12194 0.12390 0.20988 0.16819

-0.27452 -0.28625

-0.27505 -0.27363

-0.13097 -0.13248

-0.28189 -0.28892

-0.23148 -0.22697

-0.30487 -0.29303 0.02303 0.04453 0.10017 0.10535 0.20091 0.21111 0.18458 0.17444 0.16833 0.17858 0.22534 0.23399 0.47207 0.45473

-0.13326 -0.21420

-0.22701 -0.23920

-0.47396 -0.39854 0.25853 0.29904 0.30754 0.31822 0.68354 0.70236 0.26885 0.09434 -

-0.46041 -0.42263 -

-0.39791 -0.34888

-0.35662 -0.37167 -

-0.86432 -0.88108 -

0.00019 0.0001E 0.0001f 0.00017

0. 00019 0.0002C 0.00006

-0.00033

-0.00096

-0.00151

-0.00216

-0.00656

-0.01732

-0.02490

-0.01812

-0.01113

-0.02005

-0.04257

-0.07306

-0.04586

-0.00836 0.00309 0.00023 0.02709 0.06782 0.09775 0.07557 0.01251

-0.00459 0.06025 0.00358 0.02130

-0.00673 0.00678 0.04651 0.16455 0.19649 0.17785 0.20321 0.18477 0.13578 0.10408

-0.28591

-0.26399

-0.14637

-0.28994

-0.22803

-0.25889 0.06274 0.11347 0.21889 0.16537 0.19077 0.25343 0.40991

-0.27242

-0.28161

-0.29472 0.32819 0.34700 0.70393

-0.07885

-0.39988

-0.33871

-0.42655

-0.76270 0.00019 0.00019 0.00018 0.00018 I0.00018 0.00018 0.00017 0.00017 0.00019 0.00019 D0.00019 0.00018 0.00003 -0.00001

-0.00040 -0.00048 S-0.00104 -0.00112

-0.00155 -0.00160

-0.00237 -0.00266

-0.00765 -0.00886

-0.01864 -0.01996

-0.02491 -0.02470

-0.01700 -0.01620

-0.01047 -0.00981

-0.02272 -0.02488

-0.04791 -0.05392

-0.07119 -0.06834

-0.04176 -0.03721

-0.00438 -0.00093 0.00189 0.00064 0.00129 0.00244 0.03385 0.03999 0.07217 0.07643 0.09934 0.09958 0.06809 0.06061 0.00497 -0.00082

-0.00220 0.00104 0.06747 0.06963

-0.00368 -0.00515 0.01670 0.00872

-0.00214 0.00122 0.00924 0.01290 0.05907 0.07399 0.17221 0.17677 0.19757 0.19664 0.17475 0.17316 0.21065 0.21487 0.17405 0.16237 0.15532 0.18217 0.02688 -0.05528

-0.27897 -0.27317

-0.24711 -0.22100

-0.16890 -0.19589

-0.28531 -0.27585

-0.23548 -0.24944

-0.21127 -0.15463 0.07592 0.08561 0.12519 0.14027 0.22313 0.22253 0.15906 0.15455 0.20247 0.21267 0.28413 0.32823 0.34361 0.25900

-0.30191 -0.30007

-0.34248 -0.41747

-0.17596 -0.06337 0.33990 0.33907 0.39338 0.45692 0.68816 0.66048

-0.23163 -0.36092

-0.39706 -0.39615

-0.32038 -0.32165

-0.49513 -0.57072

-0.69390 -0.55416 1

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66

Caic Number GEO.HBIP.02.06

-0.35874 -0.36916

-0.19445 -0.23286

-0.28400 -0.19439 0.31917 0.30952 0.11889 0.09382

-0.08939 -0.16379

-0.35766 -0.31352 0.24947 0.25793

-0.22785 -0.24173 0.06888 0.07907

-0.10345 -0.17347

-0.48880 -0.43713

-0.12027 -0.08920 0.05299 0.02703 0.07065 0.09141 0.06440 0.06088 0.31108 0.38192 0.57247 0.52441

-0.09863 -0.24753

-0.60565 -0.54122 0.01596 0.04556 0.44716 0.38988 0.04070 0.11645 0.08494 0.01889

-0.22807 -0.20942

-0.01890 -0.05966

-0.19571 -0.16350

-0.23596 -0.23477 0.03182 0.05165

-0.01652 -0.04410

-0.01479 0.02105 0.26065 0.24801 0.00723 0.0li93 0.11034 0.13817 0.37976 0.32019

-0.35295 -0.35680

-0.22438 -0.21949

-0.04462 0.01277 0.23622 0.27206 0.11117 0.06011 0.24442 0.30932 0.44609 0.46663 0.51878 0.47820 0.13630 0.17985

-0.30051 -0.30843 0.37803 0.32079 0.15768 0.13566

-0.41917 -0.38077

-0.19626 -0.21642

-0.09112 -0.08058

-0.10991 -0.11628 0.04417 0.05541

-0.49827 -0.54867

-0.15827 -0.09703 0.18087 0.22146 0.50495 0.54043 0.46034 0.31697 0.11139 0.17069 0.00850 0.01094

-0.01088 -0.08609

-0.26267 -0.21447

-0.01330 -0.07626

-0.14099 -0.11487

-0.45442 -0.54577

-0.43749 -0.35448

-0.11796 -0.10745

-0.16006 -0.13937

-0.17216 -0.32130

-0.26982 -0.16902 0.07241 0.09687 0.47732 0.51946 0.29627 0.20613

-0.02271 -0.03980

-0.27139 -0.11183

-0.31326 -0.36560

-0.08581 0.01922 0.27589 0.24396 0.07726 0.06805

-0.24343 -0.31391

-0.24941 -0.16352 0.22757 0.15896

-0.22970 -0.19270 0.07055 0.05399

-0.25349 -0.34071

-0.37421 -0.31238

-0.05624 -0.01926

-0.00079 -0.01900 0.10381 0.10344 0.06321 0.07440 0.45240 0.51792 0.46550 0.40748

-0.38814 -0.49844

-0.45534 -0.34531 0.08475 0.15412 0.29930 0.18892 0.19458 0.24711

-0.04424 -0.10064

-0.17704 -0.13185

-0.11230 -0.16824

-0.13780 -0.13103

-0.21711 -0.18101 0.06212 0.06622

-0.06806 -0.08406 0.06159 0.10478 0.21891 0.17518 0.02509 0.04167 0.17782 0.23028 0.22848 0.10874

-0.33976 -0.31202

-0.21300 -0.20516 0.06765 0.10988 0.30101 0.31627 0.02444 0.00859 0.36142 0.38667 0.48713 0.49471 0.41285 0.31561 0.20800 0.18936

-0.25161 -0.12463 0.23817 0.16404 0.07667 -0.02406

-0.31768 -0.24933

-0.22490 -0.21591

-0.07694 -0.07653

-0.11741 -0.10784 0.04052 -0.00717

-0.56017 -0.53127

-0.04602 -0.00166 0.26308 0.31060 0.57833 0.62224 0.17187 0.05124 0.20805 0.20619 0.03044 0.06212

-0.16396 -0.22791

-0.15446 -0.08532

-0.14306 -0.19339

-0.10246 -0.10824

-0.61659 -0.65963

-0.27864 -0.21727

-0.09904 -0.09073

-0.09849 -0.03131

-0.46167 -0.55147

-0.08395 -0.02296 0.13352 0.18332 0.54670 0.56116 0.12616 0.06662

-0.06467 -0.09434

-0. 01045

-0.38359 0.10605 0.22851 0.05729

-0.36381

-0.06333 0.06798

-0.13942 0.03193

-0.42040

-0.25624

0. 01521

-0.02678 0.09543 0.09681 0.57100 0.33949

-0.58183

-0.23423 0.23575 0.08310 0.27326

-0.14817

-0.08421

-0.21587

-0.13872

-0.13458 0.06242

-0.09102 0.14836 0.12596 0.05840 0.28714

-0.01986

-0.28161

-0.19130 0.14521 0.31261

0. 01579 0.39879 0.50218 0.21803 0.12900 0.03390 0.10979

-0.14511

-0.19250

-0.19337

-0.07866

-0.08848

-0.08470

-0.47229 0.03849 0.35622 0.65354

-0. 03093 0.17737 0.09151

-0.27718

-0.02258

-0.22439

-0.13786

-0.67255

-0.17096

-0.09017 0.02783

-0.59141 0.01558 0.24344 0.55310 0.02617

-0.00013

-0.39739 0.19857 0.21238 0.04173

-0.39023

0. 04089

-0.02870

-0.07925 0.01282

-0.48231

-0.21344 0.04522

-0.01466 0.08676 0.13479 0.60588 0.26128

-0.63105

-0.13743

  • 0.32840 0.00886 0.25839

-0.18775

-0.04077

-0.24048

-0.16273

-0.08511 0.05171

-0.08584 0.19178 0.07923 0.07126 0.34364

-0.14285

-0.25798

-0.17032 0.16579 0.28092 0.04812 0.40423 0.51276 0.14202 0.02012 0.19138 0.10019

-0.26456

-0.16190

-0.16390

-0.08419

-0.05860

-0.18846

-0.39507

0. 07415 0.39907 0.66537

-0.05057 0.12858 0.10261

-0.30345 0.02388

-0.22612

-0.19040

-0.64688

-0.14392

-0.10620 0.05461

-0.56344 0.03873 0.30567 0.52017 0.00479

-0.07803

-0.43066 0.27623 0.18220

0. 01496

-0. 39758 0.13296

-0.11564

-0.01675

-0.01268

-0.51790

-0.17830

0. 06449
0. 00872 0.07673 0.18541
0. 61978 0.16575

-0.64788

-0. 05873 0.40733

-0.02819 0.21562

-0.21484

-0. 01091

-0.24554

-0.19244

-0.03710 0.03456

-0.07057 0.22758 0.04079 0.08306 0.38453

-0.24614

-0.24052

-0.14070

0. 18468 0.23236 0.09942 0.40735 0.51939
0. 09700

-0.10569 0.31858 0.11530

-0.36134

-0.15585

-0.13331

-0.09060

-0.02226

-0.30219

-0.31064 0.11036 0.43928 0.64212

-0.02579 0.07453 0.09277

-0.30819 0.04474

-0.20644

-0.26479

-0.59320

-0.12836

-0.12563 0.03787

-0.48797 0.04985 0.36968 0.46435

-0.00528

-0.17443 Rev Number: 0 Sheet Number: 133 of 196 Date: 11/06/02

-0.14915 67

-0.38666 68 0.30821 69 0.14797 70

-0.02928 71

-0.38675 72 0.20451 73

-0.18351 74 0.03456 75

-0.05133 76

-0.51673 77

-0.14849 78 0.06490 79 0.03920 80 0.06929 81 0.24472 82 0.60568 83 0.04033 84

-0.64157 85

-0.01519 86 0.44790 87

-0.01114 88 0.15588 89

-0.22932 90

-0.00414 91

-0.22620 92

-0.21894 93 0.00173 94 0.01040 95

-0.04654 96 0.25221 97 0.01710 98 0.09361 99 0.39894 100

-0.31532 101

-0.23050 102

-0.09559 103 0.20942 104 0.17217 105 0.17025 106 0.42534 107 0.52843 108 0.10387 109

-0.22198 110 0.37671 111 0.14170 112

-0.41285 113

-0.17180 114

-0.10823 115

-0.10054 116 0.01511 117

-0.41092 118

-0.23003 119 0.14456 120 0.47129 121 0.56912 122 0.03657 123 0.03323 124 0.05108 125

-0.29550 126 0.02876 127

-0.17596 128

-0.35750 129

-0.52018 130

-0.12162 131

-0.15021 132

-0.04773 133

-0.38565 134 0.05956 135 0.42696 136 0.38501 137

-0.01292 138

-0.18146 139

-0.12636 -0.15483

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 134 of 196 Date: 11/06/02

-0.17085 -0.14170 -0.09574 -0.03703 0.02678 0.08751 0.13830 0.17333 140 0.19049 0.19147 0.17783 0.15544 0.12912 0.10353 0.08559 0.07714 141 0.08294 0.10275 0.13439 0.17519 0.21675 0.25438 0.27972 0.28867 142 0.27907 0.25083 0.20901 0.15717 0.10441 0.05624 0.01898 -0.00437 143

-0.01281 -0.00625 0.01036 0.03469 0.05998 0.08330 0.10127 0.11207 144 0.11834 0.12071 0.12445 0.13167 0.14387 0.16133 0.17965 0.19497 145 0.20214 0.19710 0.17898 0.14813 0.10953 0.06905 0.03363 0.01051 146 0.00307 0.01386 0.04017 0.07794 0.11989 0.15737 0.18476 0.19578 147 0.18975 0.16703 0.13187 0.09042 0.04858 0.01358 -0.01103 -0.02195 148

-0.01972 -0.00658 0.01422 0.03750 0.06015 0.07847 0.09145 0.09929 149 0.10335 0.10661 0.11222 0.12360 0.14290 0.17154 0.20819 0.25065 150 0.29350 0.33103 0.35795 0.36857 0.36161 0.33554 0.29370 0.24044 151 0.18025 0.11969 0.06194 0.01091 -0.03105 -0.06341 -0.08434 -0.09451 152

-0.09400 -0.08338 -0.06591 -0.04324 -0.01959 0.00178 0.01901 0.03005 153 0.03467 0.03289 0.02493 0.01138 -0.00623 -0.02748 -0.04835 -0.06679 154

-0.07913 -0.08142 -0.07473 -0.05772 -0.03477 -0.00874 0.01645 0.03609 155 0.04989 0.05563 0.05582 0.05156 0.04607 0.04218 0.04084 0.04425 156 0.04908 0.05438 0.05500 0.04679 0.02842 -0.00308 -0.04332 -0.09000 157

-0.13674 -0.17753 -0.20863 -0.22523 -0.22811 -0.21700 -0.19589 -0.16846 158

-0.13874 -0.11142 -0.08777 -0.07048 -0.05789 -0.04891 -0.04249 -0.03610 159

-0.03101 -0.02712 -0.02512 -0.02640 -0.02954 -0.03474 -0.03968 -0.04232 160

-0.04245 -0.03860 -0.03264 -0.02524 -0.01865 -0.01520 -0.01496 -0.01950 161

-0.02649 -0.03474 -0.04252 -0.04772 -0.05088 -0.05112 -0.05117 -0.05314 162

-0.05829 -0.06883 -0.08419 -0.10406 -0.12756 -0.15326 -0.17927 -0.20437 163

-0.22503 -0.23932 -0.24522 -0.24040 -0.22802 -0.20884 -0.18843 -0.17167 164

-0.16052 -0.15891 -0.16410 -0.17511 -0.18823 -0.19935 -0.20751 -0.20968 165

-0.20778 -0.20257 -0.19509 -0.18786 -0.17864 -0.16809 -0.15346 -0.13213 166

-0.10715 -0.07769 -0.05132 -0.03311 -0.02576 -0.03537 -0.05482 -0.08171 167

-0.10798 -0.12484 -0.13200 -0.12459 -0.10917 -0.09011 -0.07256 -0.06390 168

-0.06400 -0.07550 -0.09490 -0.11924 -0.14485 -0.16687 -0.18372 -0.19252 169

-0.19374 -0.18772 -0.17551 -0.15897 -0.13922 -0.11766 -0.09584 -0.07507 170

-0.05567 -0.03876 -0.02253 -0.00606 0.01150 0.03212 0.05407 0.07729 171 0.10045 0.12170 0.14295 0.16357 0.18694 0.21511 0.24751 0.28533 172 0.32205 0.35428 0.37421 0.37508 0.35543 0.31141 0.25099 0.17875 173 0.10610 0.04418 -0.00190 -0.02371 -0.02533 -0.00800 0.02080 0.05219 174 0.08287 0.10602 0.12210 0.13024 0.13153 0.12851 0.12069 0.10982 175 0.09475 0.07491 0.05110 0.02271 -0.00728 -0.03706 -0.06470 -0.08723 176

-0.10513 -0.11753 -0.12458 -0.12726 -0.12477 -0.11754 -0.10494 -0.08643 177

-0.06340 -0.03611 -0.00647 0.02363 0.05332 0.08104 0.10709 0.13150 178 0.15454 0.17648 0.19735 0.21735 0.23682 0.25563 0.27336 0.28984 179 0.30288 0.31120 0.31263 0.30535 0.28966 0.26499 0.23441 0.20019 180 0.16620 0.13632 0.11265 0.09774 0.09120 0.09284 0.10001 0.11028 181 0.12018 0.12628 0.12689 0.11971 0.10638 0.08755 0.06686 0.04765 182 0.03226 0.02391 0.02199 0.02685 0.03607 0.04731 0.05840 0.06658 183 0.07125 0.07119 0.06759 0.06135 0.05431 0.04834 0.04472 0.04491 184 0.04855 0.05564 0.06429 0.07283 0.07920 0.08140 0.07835 0.06864 185 0.05361 0.03405 0.01246 -0.00874 -0.02740 -0.04087 -0.04859 -0.04962 186

-0.04429 -0.03337 -0.01741 0.00221 0.02442 0.04780 0.07015 0.08984 187 0.10372 0.10987 0.10600 0.08982 0.06325 0.02681 -0.01483 -0.05782 188

-0.09851 -0.13228 -0.15946 -0.17858 -0.19236 -0.20332 -0.21245 -0.22257 189

-0.23199 -0.24041 -0.24616 -0.24674 -0.24275 -0.23347 -0.21962 -0.20229 190

-0.18125 -0.15744 -0.13059 -0.10045 -0.06864 -0.03565 -0.00355 0.02584 191 0.05239 0.07480 0.09492 0.11357 0.13204 0.15226 0.17271 0.19333 192 0.21166 0.22538 0.23365 0.23459 0.22961 0.21939 0.20580 0.19157 193 0.17755 0.16547 0.15719 0.15302 0.15619 0.16796 0.18803 0.21750 194 0.24962 0.28116 0.30451 0.31226 0.30513 0.27955 0.24430 0.20494 195 0.16833 0.14364 0.12822 0.12466 0.12465 0.12135 0.11131 0.08703 196 0.05341 0.01121 -0.03297 -0.07171 -0.10428 -0.12589 -0.14077 -0.15148 197

-0,16082 -0.17378 -0.18938 -0.20877 -0.23001 -0.25086 -0.27017 -0.28589 198

-0.29755 -0.30437 -0.30676 -0.30521 -0.30126 -0.29591 -0.29094 -0.28772 199

-0.28523 -0.28385 -0.27950 -0.27001 -0.25161 -0.22103 -0.18018 -0.12870 200

-0.07490 -0.02450 0.01473 0.03453 0.03471 0.01212 -0.02628 -0.07507 201

-0.12672 -0.17212 -0.20825 -0.23009 -0.23853 -0.23424 -0.22052 -0.20137 202

-0.18016 -0.16102 -0.14560 -0.13604 -0.13147 -0.13153 -0.13359 -0.13528 203

-0.13479 -0.12954 -0.12062 -0.10786 -0.09374 -0.08060 -0.06958 -0.06308 204

-0.05986 -0.05964 -0.06101 -0.06225 -0.06287 -0.06171 -0.05924 -0.05575 205

-0.05204 -0.04879 -0.04708 -0.04766 -0.05046 -0.05589 -0.06134 -0.06546 206

-0.06487 -0.05678 -0.04050 -0.01428 0.01826 0.05521 0.09155 0.12243 207 0.14629 0.15989 0.16630 0.16682 0.16614 0.16890 0.17662 0.19266 208 0.21414 0.23953 0.26492 0.28627 0.30159 0.30768 0.30631 0.29793 209 0.28601 0.27394 0.26382 0.25881 0.25839 0.26290 0.27064 0.27984 210 0.28912 0.29618 0.30074 0.30211 0.30028 0.29535 0.28806 0.27901 211 0.26939 0.26065 0.25270 0.24620 0.24029 0.23396 0.22702 0.21853 212

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 135 of 196 Date: 11/06/02 0.20870 0.09905

-0.42121

-0.56508

-0.50352

-0.07009 0.21450 0.29815 0.13791

0. 10658

-0.09682 0.07856

0. 18259

-0.04939

-0.35046

-0.22205 0.01987 0.05098

-0.06972 0.18105

-0.29042

-0.12786

-0.15998

-0.07106

-0.08912 0.00296

0. 09180 0.14853

-0.55645

-0.19210 0.18014 0.22174 0.20041 0.19280

-0.05094 0.23440

-0.16497

-0.29432

-0.56524

-0.19640 0.16733 0.08149 0.19029 0.13775 0.13941 0.27860 0.39342 0.15621

-0.08177 0.02232

-0.34180

-0.03697 0.00759 0.01351

-0.03037

-0.00306

-0.03664

-0.15493 0.04518 0.30519 0.24339 0.19753 0.16433 0.17101 0.05563

-0.36098

-0.40738

-0.21363 0.01091

-0.23004

-0.23353

-0.13149 0.00972 0.19767 0.18562 0.17269 0.07428 0.03819 -0.01340

-0.48761 -0.53767 -0.56845

-0.55300 -0.54168 -0.53414

-0.46622 -0.41567 -0.35229

-0.04008 -0.01377 0.01491 0.24313 0.26156 0.26625 0.31882 0.33214 0.32668 0.12516 0.12621 0.13831 0.07684 0.04561 0.01906

-0.11550 -0.12664 -0.12553 0.12461 0.15623 0.16543 0.24229 0.30760 0.36588

-0.24118 -0.41372 -0.53418

-0.26850 -0.20742 -0.18109

-0.21330 -0.19732 -0.17706 0.07801 0.12943 0.16687 0.00121 -0.03975 -0.06609

-0.06842 -0.06230 -0.05227 0.22518 0.24067 0.21425

-0.35571 -0.38713 -0.37357

-0.11308 -0.11593 -0.12933

-0.12980 -0.09409 -0.06141

-0.08404 -0.09371 -0.10088

-0.04570 0.00473 0.05454

-0.00558 0.00659 0.04993 0.06619 0.06002 0.09850 0.00184 -0.17487 -0.34927

-0.49897 -0.43999 -0.39080

-0.13871 -0.08660 -0.03506 0.23702 0.28874 0.33371 0.17634 0.14123 0.12841 0.22647 0.25094 0.27129 0.15628 0.12057 0.08515

-0.03638 -0.00099 0.05407 0.19842 0.14162 0.07292

-0.17744 -0.18778 -0.20084

-0.30950 -0.32908 -0.35675

-0.57025 -0.55085 -0.50513

-0.15539 -0.11614 -0.07251 0.17635 0.16699 0.14032 0.10633 0.13398 0.15687 0.19541 0.20044 0.20397 0.12293 0.11507 0.11671 0.13345 0.12995 0.13379 0.30455 0.32250 0.33037 0.41653 0.43039 0.42680 0.09394 0.04116 0.00265

-0.07779 -0.06293 -0.03427

-0.03853 -0.11780 -0.20802

-0.28408 -0.21669 -0.15463

-0.03655 -0.03687 -0.03439 0.02344 0.03925 0.05390

-0.01318 -0.03774 -0.05534

-0.01963 -0.01200 -0.00982 0.00428 0.01111 0.01515

-0.05690 -0.07756 -0.09663

-0.15303 -0.14404 -0.12675 0.08507 0.12405 0.16113 0.31907 0.32492 0.32134 0.24017 0.24282 0.25129 0.16029 0.12475 0.09876 0.19215 0.21367 0.22338 0.16014 0.15173 0.14539 0.01399 -0.03496 -0.08940

-0.40136 -0.43284 -0.45421

-0.38008 -0.35211 -0.32592

-0.19072 -0.16545 -0.13733 0.01987 0.01435 -0.00926

-0.25669 -0.27240 -0.27561

-0.22556 -0.21718 -0.20624

-0.11384 -0.09547 -0.07602 0.02335 0.03590 0.04786 0.15960

-0.07924

-0.58375

-0.53124

-0.28369 0.04705 0.26515 0.30580 0.15293

-0.00514

-0.11025 0.16155 0.39222

-0.59843

-0.17746

-0.15045

0. 18407

-0.08054

-0.02912 0.15326

-0.33205

-0.15072

-0.03834

-0. 10588 0.09069 0.09950 0.15537

-0.49479

-0.34668 0.01321 0.35883 0.12794 0.28034 0.05066 0.11841 0.00301

-0.21669

-0.39373

-0.44344

-0.02416 0.10838 0.17403 0.20245 0.12362 0.14747 0.33511 0.40437

-0.02614

-0.00130

-0.29161

-0.10150

-0.02978 0.06315

-0.06508

-0.01013 0.01527

-0.11412

-0.10223 0.19619 0.31056 0.25866 0.08486 0.22355 0.13848

-0.14707

-0.46468

-0.30136

-0.10685

-0.04622

-0.27035

-0.19376

-0.05661 0.05754 0.14610 0.13212

-0.16075 -0.24925

-0.58794 -0.58359

-0.53329 -0.53229

-0.21741 -0.15677 0.08706 0.13033 0.26367 0.26581 0.26458 0.21648 0.15731 0.15268

-0.02840 -0.05042

-0.07748 -0.03203 0.14754 0.13944 0.36245 0.27810

-0.59219 -0.53741

-0.18986 -0.20822

-0.12035 -0.08180 0.17623 0.14793

-0.08224 -0.07934 0.00999 0.06044 0.05137 -0.06601

-0.27522 -0.21191

-0.16917 -0.18000

-0.03176 -0.03788

-0.11421 -0.11716 0.09310 0.07551 0.13247 0.14712 0.21808 0.25519

-0.58127 -0.61572

-0.31178 -0.27559 0.05181 0.09244 0.35251 0.32582 0.13792 0.15642 0.27576 0.25750 0.01451 -0.01808 0.17802 0.22361

-0.05962 -0.10950

-0.23749 -0.25824

-0.44146 -0.49093

-0.37400 -0.30529 0.03235 0.08729 0.11780

-0.33867

-0.57531

-0.52354

-0. 10878 0.17466 0.27995 0.17249 0.13403

-0.07455 0.02339 0.15088 0.13074

-0.44901

-0.21839

-0.03406 0.10245

-0.07440 0.12404

-0.18588

-0.16352

-0.17735

-0.05290

-0.10966 0.03831 0.12470 0.23053

-0.60070

-0.23559 0.13387 0.27599 0.17583 0.22812

-0.04165 0.24300

-0.14305

-0.27703

-0.53566

-0.24682 0.13487 0.06687 0.18808 0.15751 0.14194 0.24409 0.37097 0.22748

-0.07670 0.05078

-0.37688

-0.03778

-0.00536 0.03739

-0.04414

-0.00826

-0.01762

-0.15087 0.00462 0.28475 0.25589 0.22843 0.13294 0.18558 0.08818

-0.31394

-0.43250

_0.23544

-0.01083

-0.19064

-0.24181

-0.14820

-0.00480 0.06270 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235

.236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 0.08153

0. 18241 0.19309 0.13297 0.17379 0.34095 0.35854

-0. 04813 0.03251

-0.35178

-0.06696

-0.02410 0.06376

-0.06433

-0.01121 0.00925

-0.12947

-0.07076 0.22905 0.29278 0.25929 0.08871 0.21478 0.12817

-0.20497

-0.46333

-0.27841

-0.07381

-0.09339

-0.26158

-0.17953

-0.03804 0.06424 0.06514 0.18620 0.17780 0.14051 0.20704 0.35136 0.29792

-0.06360 0.05339

-0.38379

-0.04636

-0.01565 0.05566

-0.05668

-0.01151

-0.00176

-0.14175

-0.03449 0.25864 0.27339 0.25092 0.10549 0.20067 0.11235

-0.26137

-0.45220

-0.25672

-0.04111

-0.14370

-0.25069

-0.16396

-0.02045 0.06642

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 136 of 196 Date: 11/06/02 0.05359 0.03853 0.02058 0.00128 -0.01643 -0.02927 -0.03876 -0.04367 286

-0.04881 -0.05751 -0.07098 -0.09288 -0.11803 -0.14451 -0.16641 -0.17737 287

-0.17752 -0.16374 -0.14095 -0.11285 -0.08322 -0.05772 -0.03668 -0.02228 288

-0.01309 -0.00772 -0.00482 -0.00205 0.00093 0.00535 0.01069 0.01640 289 0.02240 0.02784 0.03299 0.03781 0.04202 0.04595 0.04894 0.05049 290 0.05129 0.05121 0.05168 0.05384 0.05780 0.06438 0.07250 0.08140 291 0.09051 0.09852 0.10579 0.11224 0.11766 0.12230 0.12565 0.12740 292 0.12754 0.12591 0.12273 0.11825 0.11285 0.10676 0.10081 0.09535 293 0.09102 0.08845 0.08676 0.08583 0.08386 0.07931 0.07161 0.05969 294 0.04435 0.02621 0.00669 -0.01259 -0.02975 -0.04329 -0.05117 -0.05187 295

-0.04530 -0.03063 -0.01064 0.01326 0.03833 0.06154 0.08402 0.10451 296 0.12728 0.15443 0.18809 0.23108 0.27844 0.32889 0.37208 0.40043 297 0.40803 0.38686 0.34260 0.27586 0.19915 0.12352 0.05545 0.00629 298

-0.02838 -0.04808 -0.05920 -0.06975 -0.07884 -0.09126 -0.10080 -0.10384 299

-0.09783 -0.07751 -0.04728 -0.00812 0.03291 0.06917 0.09673 0.10969 300 0.10946 0.09566 0.07294 0.04598 0.01856 -0.00408 -0.02095 -0.03003 301

-0.03232 -0.02914 -0.02203 -0.01314 -0.00416 0.00312 0.00808 0.00963 302 0.00926 0.00759 0.00639 0.00762 0.01069 0.01643 0.02240 0.02665 303 0.02827 0.02525 0.01867 0.00882 -0.00302 -0.01515 -0.02703 -0.03757 304

-0.04656 -0.05384 -0.05948 -0.06380 -0.06736 -0.07087 -0.07507 -0.08075 305

-0.08883 -0.09984 -0.11472 -0.13417 -0.15773 -0.18541 -0.21544 -0.24626 306

-0.27635 -0.30349 -0.32708 -0.34639 -0.36002 -0.36810 -0.36909 -0.36244 307

-0.34984 -0.33158 -0.31306 -0.29763 -0.28988 -0.29449 -0.31016 -0.33797 308

-0.37097 -0.40448 -0.43156 -0.44500 -0.44466 -0.42700 -0.39976 -0.36761 309

-0.33790 -0.31949 -0.31108 -0.31602 -0.32627 -0.33571 -0.33897 -0.32784 310

-0.30430 -0.26709 -0.22166 -0.17362 -0.12690 -0.08748 -0.05643 -0.03589 311

-0.02474 -0.02176 -0.02455 -0.03023 -0.03703 -0.04224 -0.04598 -0.04741 312

-0.04718 -0.04612 -0.04325 -0.03894 -0.03052 -0.01682 0.00424 0.03449 313 0.07216 0.11726 0.16373 0.20777 0.24421 0.26739 0.27915 0.27793 314 0.27135 0.26489 0.26370 0.27487 0.29557 0.32672 0.36078 0.39124 315 0.41396 0.42215 0.41825 0.40176 0.37843 0.35295 0.32811 0.30964 316 0.29623 0.28929 0.28610 0.28311 0.27900 0.27012 0.25928 0.24727 317 0.23639 0.23127 0.23102 0.23629 0.24479 0.25439 0.26564 0.27679 318 0.28653 0.29498 0.29985 0.29897 0.29078 0.27403 0.24915 0.21608 319 0.17783 0.13739 0.09681 0.05874 0.02450 -0.00438 -0.02654 -0.04164 320

-0.04908 -0.04848 -0.04075 -0.02632 -0.00762 0.01348 0.03512 0.05457 321 0.07342 0.09174 0.10988 0.12873 0.14660 0.16355 0.17652 0.18295 322 0.18212 0.17205 0.15462 0.13108 0.10345 0.07497 0.04758 0.02275 323 0.00168 -0.01496 -0.02615 -0.03122 -0.03227 -0.03002 -0.02869 -0.03125 324

-0.03958 -0.05679 -0.07913 -0.10519 -0.12899 -0.14513 -0.15182 -0.14519 325

-0.12856 -0.10307 -0.07343 -0.04492 -0.01850 0.00206 0.01939 0.03454 326 0.04910 0.06637 0.08400 0.10234 0.11789 0.12751 0.13171 0.12830 327 0.12185 0.11504 0.11056 0.11284 0.11966 0.13170 0.14520 0.15609 328 0.16485 0.16849 0.17035 0.17224 0.17388 0.17797 0.17883 0.17435 329 0.16064 0.13269 0.09474 0.04672 -0.00259 -0.04596 -0.07953 -0.09627 330

-0.10040 -0.09284 -0.07985 -0.06857 -0.06073 -0.06134 -0.06808 -0.07965 331

-0.09403 -0.10748 -0.11922 -0.12747 -0.13129 -0.13073 -0.12516 -0.11473 332

-0.10148 -0.08605 -0.07287 -0.06449 -0.06278 -0.07057 -0.08288 -0.09857 333

-0.10901 -0.10791 -0.09296 -0.05883 -0.01512 0.03431 0.07579 0.09715 334 0.0O9505 0.06107 0.00670 -0.06231 -0.13025 -0.18106 -0.20926 -0.20380 335

-0.17189 -0.11682 -0.04953 0.01722 0.07849 0.12426 0.15684 0.17560 336 0.18361 0.18590 0.18081 0.17101 0.15152 0.11968 0.07364 0.01021 337

-0.06558 -0.15132 -0.23702 -0.31459 -0.37508 -0.40954 -0.41638 -0.39207 338

-0.34468 -0.27954 -0.20837 -0.14302 -0.08870 -0.05457 -0.03657 -0.03366 339

-0.03995 -0.04759 -0.05578 -0.05971 -0.06185 -0.06382 -0.06661 -0.07325 340

-0.08236 -0.09410 -0.10681 -0.11870 -0.12869 -0.13527 -0.13813 -0.13681 341

-0.13218 -0.12495 -0.11670 -0.10888 -0.10260 -0.09894 -0.09747 -0.09842 342

-0.09994 -0.10101 -0.09921 -0.09233 -0.08075 -0.06338 -0.04392 -0.02426 343

-0.00754 0.00230 0.00777 0.00812 0.00902 0.01487 0.02738 0.05115 344 0.08117 0.11607 0.15038 0.17815 0.20103 0.21598 0.23133 0.25129 345 0.28097 0.32733 0.38309 0.44731 0.50511 0.54466 0.55822 0.53370 346 0.47838 0.39352 0.29257 0.18955 0.09074 0.00844 -0.05926 -0.11150 347

-0.15000 -0.17999 -0.19969 -0.21117 -0.21369 -0.20604 -0.19123 -0.16996 348

-0.14602 -0.12285 -0.10159 -0.08478 -0.07108 -0.05994 -0.04989 -0.03876 349

-0.02639 -0.01165 0.00503 0.02298 0.04236 0.06227 0.08262 0.10360 350 0.12307 0.14068 0.15459 0.16271 0.16796 0.16960 0.17323 0.18246 351 0.19608 0.21703 0.23439 0.24293 0.23342 0.19567 0.13499 0.04947 352

-0.04445 -0.13449 -0.21003 -0.25591 -0.27724 -0.27176 -0.25272 -0.23212 353

-0.21559 -0.21567 -0.22573 -0.24492 -0.26468 -0.27431 -0.27398 -0.25716 354

-0.22961 -0.19551 -0.15647 -0.11892 -0.07847 -0.03480 0.01370 0.07096 355 0.13129 0.19342 0.25064 0.29649 0.33086 0.34986 0.35966 0.36378 356 0.36720 0.37657 0.39027 0.41029 0.43085 0.44706 0.45568 0.45079 357 0.43435 0.40581 0.36813 0.32544 0.27798 0.22857 0.17702 0.12319 358

Caic Number: GEO.HBIP.02.06 0.06945

-0.19111

-0.11866

-0.08085

-0.40540

-0.23370

-0.00771

-0.03221

-0.15552

-0.16775 0.10961 0.33606 0.36721 0.22105

-0.06180 0.12979 0.20912

-0.11293

-0. 08045 0.10059 0.14129

-0.18446

-0.26857

-0.16959

-0.08687

-0.32699

-0.26144

-0. 08186

-0.08797 0.09197 0.17832

0. 12001 0.23070 0.25811

-0.08369

-0.18207 0.01089

0. 06541

-0.18602

-0.07665 0.06532 0.07208

-0.00341

-0. 08895 0.09960

0. 18321 0.14688

-0.16778

-0.32840

-0.09880 0.16902 0.02152 0.17864 0.09811

0. 08955

-0.09790

-0.15990

-0.02566

-0.09444

-0.14208

-0.08814

-0.03624 0.02575

-0. 06511 0.08076 0.29378 0.33223 0.17794

-0.04470

-0.09867

-0.00616 0.15634

-0.01515 0.01638

-0.19411

-0.11678

-0.08563

-0.43079

-0.18589

-0.01033

-0.03008

-0.18721

-0.12061 0.12785 0.35270 0.38538 0.13257

-0.01210 0.13163 0.18877

-0.14636

-0.04811 0.13150 0.09650

-0.20686

-0.26080

-0.15915

-0.10382

-0.34722

-0.23216

-0.05592

-0.09762 0.11234 0.18257 0.11682 0.25538 0.21404

-0.10364

-0.16054 0.01578 0.04930

-0.20184

-0.05075 0.08574 0.04765

-0.01183

-0.06875 0.11211 0.19260 0.12123

-0.23524

-0.28194

-0.08292 0.18722 0.02935 0.16311 0.10717 0.06702

-0.11927

-0.13698

-0.01557

-0.12165

-0.14218

-0.07205

-0.03400 0.03215

-0.07275 0.10735 0.32002 0.31997 0.14134

-0.06142

-0.08578 0.01808 0.13866

-0.02751

-0.03328

-0.19090

-0.11663

-0.10337

-0.43890

-0.14128

-0.01671

-0.03120

-0.21563

-0.07124 0.14907 0.36122 0.40343 0.04483 0.03900 0.13912 0.15718

-0.16989

-0.01913 0.16221 0.04705

-0.22567

-0.24942

-0.14717

-0.12965

-0.35963

-0.20557

-0.03409

-0.09564 0.12656 0.18280 0.11927 0.27794 0.16265

-0.12191

-0.13120 0.02051 0.02359

-0.20722

-0.02846 0.10462 0.02555

-0.02560

-0.04184 0.12286 0.20002 0.09294

-0.29924

-0.23507

-0.06124 0.18899 0.05193 0.14209 0.11665 0.04180

-0.13990

-0.11210

-0.00796

-0.14376

-0.14332

-0.05820

-0.03012 0.03304

-0.07117 0.13237 0.34154 0.30735 0.10424

-0.07702

-0.07211 0.04720

0. 11383

-0.04027

-0.07691

-0. 18111

-0.11622

-0.13875

-0.42907

-0.10128

-0.02508

-0.03844

-0.23838

-0.02524 0.17619 0.36125 0.41675

-0.03149 0.08139 0.15567 0.11686

-0.18198 0.00272

0. 18871

-0.00224

-0.24170

-0.23480

-0.13136

-0.16230

-0.36352

-0.18429

-0.02070

-0.07737 0.13657 0.17720 0.12767 0.29703 0.10744

-0.14233

-0.09670 0.02968

-0.01032

-0.20154

-0.01094 0.11930 0.00977

-0.04583

-0.01229 0.13317 0.20468 0.06414

-0.35282

-0.19549

-0.03162 0.17083 0.08625 0.12165 0.12399 0.01552

-0.16023

-0. 08999

-0.00396

-0.15588

-0.14379

-0.04882

-0.02455 0.02634

-0.05853 0.15653 0.35577 0.29508 0.06970

-0.09208

-0.06066 0.08050

0. 08599

-0.05537

-0.11421

-0.16770

-0.11368

-0.18680

-0.40460

-0.06765

-0.03276

-0.05162

-0.25123 0.01552 0.20753 0.35729 0.41785

-0.08913 0.11319 0.17585 0.07037

-0.18189 0.02088 0.20683

-0.04935

-0.25455

-0.21917

-0.11478

-0.19899

-0.35841

-0.16522

-0.01709

-0.04813 0.14413 0.16754 0.14151 0.30973 0.05367

-0.16148

-0.06216 0.04075

-0.04929

-0.18652 0.00387 0.12728

-0. 00016

-0.06718 0.01764 0.14320 0.20492 0.03133

-0.39033

-0.16332 0.00507 0.14002 0.12381 0.10398 0.12780

-0.01053

-0.17633

-0.07051

-0.00632

-0.16056

-0.14175

-0.04283

-0.01681 0.01328

-0.03755 0.18101 0.36293 0.28081 0.03842

-0.10415

-0.05052 0.11274 0.05792

-0.07315

-0.14361

-0.15184

-0.10604

-0.24577

-0.37036

-0.04113

-0.03706

-0.07099

-0.25070 0.04766 0.24281 0.35242 0.39962

-0.11923 0.12937 0.19587 0.02185

-0.16863 0.03645 0.21116

-0.09110

-0.26416

-0.20429

-0.09811

-0.23538

-0.34341

-0.14754

-0.02732

-0.01116 0.15274 0.15457 0.15978 0.31450

-0.16581

-0.13686

-0.09669

-0.30701

-0.32804

-0.02221

-0.03839

-0.09585

-0.23660 0.07307 0.27812 0.35061 0.36103

-0.12359 0.13501 0.21127

-0.02671

-0.14560 0.05303 0.20193

-0.12756

-0.26993

-0.19053

-0.08572

-0.27019

-0.32106

-0.12890

-0.04513 0.02815 0.16129 0.14075 0.18166 0.30841 0.00743 -0.03157

-0.17878 -0.19003

-0.03319 -0.01035 0.05422 0.06530

-0.08934 -0.12760

-0.16353 -0.13568 0.01706 0.03070 0.12523 0.11473

-0.00304 -0.00270

-0.08569 -0.09779 0.04392 0.06664 0.15309 0.16321 0.19909 0.18758

-0.00610 -0.05097

-0,40409 -0.39719

-0.14037 -0.12402 0.04854 0.09328 0.10039 0.06205 0.15503 0.17718 0.09330 0.08905 0.12668 0.12002

-0.03432 -0.05682

-0.18551 -0.18664

-0.05629 -0.04489

-0.01839 -0.03780

-0.15776 -0.15150

-0.13386 -0.12193

-0.03969 -0.03846

-0.00693 0.00411

-0.00609 -0.02775

-0.01022 0.02054 0.20758 0.23548 0.36205 0.35555 0.26270 0.24008 0.01259 -0.00937

-0.11141 -0.11340

-0.04295 -0.03443 0.13938 0.15742 0.03396 0.01368

-0.09384 -0.11705 Rev Number: 0 Sheet Number: 137 of 196 Date: 11/06/02

-0.18194 359

-0.12594 360

-0.08615 361

-0.36173 362

-0.28182 363

-0.01145 364

-0.03580 365

-0.12452 366

-0.20744 367 0.09254 368 0.31008 369 0.35592 370 0.29894 371

-0.10154 372 0.13328 373 0.21581 374

-0.07252 375

-0.11448 376 0.07488 377 0.17748 378

-0.15846 379

-0.27147 380

-0.17979 381

-0.08174 382

-0.30115 383

-0.29237 384

-0.10602 385

-0.06788 386 0.06271 387 0.17055 388 0.12873 389 0.20563 390 0.28934 391

-0.06063 392

-0.19113 393 0.00294 394 0.06953 395

-0.16062 396

-0.10589 397 0.04717 398 0.09559 399

-0.00172 400

-0.09838 401 0.08491 402 0.17335 403 0.16941 404

-0.10622 405

-0.36934 406

-0.11124 407 0.13574 408 0.03468 409 0.18391 410 0.09123 411 0.10738 412

-0.07758 413

-0.17692 414

-0.03468 415

-0.06503 416

-0.14620 417

-0.10575 418

-0.03745 419 0.01588 420

-0.04871 421 0.05110 422 0.26503 423 0.34497 424 0.21110 425

-0.02804 426

-0.10824 427

-0.02274 428 0.16253 429

-0.00213 430

-0.14218 431

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 138 of 196 Date: 1/06/02

-0.16692 -0.18975 -0.20725 -0.21680 -0.21712 -0.20618 -0.18669 -0.15996 432

-0.13004 -0.10098 -0.07461 -0.05409 -0.03828 -0.02702 -0.01803 -0.00905 433 0.00133 0.01516 0.03147 0.05022 0.06850 0.08390 0.09407 0.09594 434 0.08987 0.07520 0.05386 0.02796 -0.00088 -0.03015 -0.05864 -0.08497 435

-0.10786 -0.12657 -0.14048 -0.14905 -0.15307 -0.15307 -0.15024 -0.14598 436

-0.14087 -0.13615 -0.13207 -0.12882 -0.12665 -0.12558 -0.12631 -0.12904 437

-0.13427 -0.14239 -0.15262 -0.16487 -0.17714 -0.18819 -0.19671 -0.20098 438

-0.20215 -0.20019 -0.19738 -0.19583 -0.19608 -0.19996 -0.20590 -0.21316 439

-0.22071 -0.22664 -0.23159 -0.23499 -0.23760 -0.24035 -0.24235 -0.24400 440

-0.24349 -0.23963 -0.23209 -0.21950 -0.20386 -0.18561 -0.16670 -0.14924 441

-0.13159 -0.11457 -0.09337 -0.06509 -0.02784 0.02190 0.07951 0.14329 442 0.20664 0.26293 0.31005 0.34325 0.36496 0.37664 0.38074 0.38123 443 0.37952 0.37776 0.37724 0.37840 0.38119 0.38566 0.38843 0.38775 444 0.37983 0.36115 0.33256 0.29284 0.24741 0.20011 0.15576 0.12015 445 0.09350 0.07820 0.07096 0.06922 0.07032 0.07009 0.06895 0.06537 446 0.06135 0.05873 0.05788 0.06068 0.06563 0.07219 0.07916 0.08475 447 0.08912 0.09177 0.09323 0.09400 0.09436 0.09488 0.09605 0.09812 448 0.10141 0.10611 0.11142 0.11693 0.12095 0.12210 0.11943 0.11170 449 0.09934 0.08254 0.06261 0.04090 0.01927 -0.00054 -0.01669 -0.02759 450

-0.03260 -0.03100 -0.02395 -0.01233 0.00174 0.01619 0.02925 0.03893 451 0.04493 0.04641 0.04447 0.03995 0.03390 0.02781 0.02158 0.01587 452 0.00966 0.00216 -0.00692 -0.01838 -0.03147 -0.04584 -0.06019 -0.07325 453

-0.08375 -0.09053 -0.09260 -0.08926 -0.08070 -0.06703 -0.05015 -0.03166 454

-0.01395 0.00054 0.01018 0.01318 0.00922 -0.00207 -0.01963 -0.04249 455

-0.06868 -0.09618 -0.12342 -0.14822 -0.17024 -0.18861 -0.20288 -0.21341 456

-0.21862 -0.21816 -0.21140 -0.19750 -0.17865 -0.15576 -0.13211 -0.11077 457

-0.09289 -0.08083 -0.07323 -0.06942 -0.06767 -0.06585 -0.06295 -0.05743 458

-0.04929 -0.03838 -0.02546 -0.01141 0.00275 0.01571 0.02701 0.03589 459 0.04228 0.04622 0.04772 0.04715 0.04484 0.04098 0.03667 0.03258 460 0.02940 0.02805 0.02802 0.02930 0.03119 0.03280 0.03445 0.03571 461 0.03744 0.04037 0.04459 0.05071 0.05823 0.06685 0.07629 0.08598 462 0.09591 0.10583 0.11578 0.12568 0.13550 0.14535 0.15488 0.16393 463 0.17225 0.17946 0.18581 0.19099 0.19545 0.19961 0.20257 0.20433 464 0.20323 0.19809 0.18880 0.17432 0.15667 0.13689 0.11667 0.09819 465 0.08085 0.06532 0.04996 0.03351 0.01546 -0.00529 -0.02734 -0.05019 466

-0.07106 -0.08792 -0.09851 -0.10061 -0.09482 -0.08084 -0.06253 -0.04282 467

-0.02601 -0.01670 -0.01637 -0.02746 -0.04862 -0.07868 -0.11481 -0.15384 468

-0.19258 -0.22764 -0.25698 -0.27830 -0.29178 -0.29724 -0.29648 -0.29126 469

-0.28305 -0.27397 -0.26387 -0.25326 -0.24115 -0.22648 -0.20836 -0.18564 470

-0.15788 -0.12492 -0.08701 -0.04483 -0.00011 0.04559 0.08884 0.12718 471 0.15700 0.17531 0.18152 0.17419 0.15716 0.13263 0.10616 0.08299 472 0.06538 0.05730 0.05624 0.06117 0.06833 0.07326 0.07461 0.06908 473 0.05771 0.04092 0.01948 -0.00448 -0.03116 -0.05930 -0.08843 -0.11829 474

-0.14603 -0.17046 -0.18777 -0.19521 -0.19147 -0.17458 -0.14770 -0.11242 475

-0.07436 -0.03863 -0.00856 0.01116 0.02176 0.02294 0.01809 0.01087 476 0.00335 -0.00089 -0.00171 0.00159 0.00872 0.01873 0.03113 0.04492 477 0.05918 0.07305 0.08578 0.09657 0.10560 0.11262 0.11831 0.12325 478 0.12729 0.13069 0.13240 0.13175 0.12751 0.11862 0.10466 0.08515 479 0.06115 0.03335 0.00424 -0.02422 -0.04950 -0.06912 -0.08244 -0.08831 480

-0.08830 -0.08361 -0.07657 -0.06971 -0.06463 -0.06337 -0.06615 -0.07342 481

-0.08434 -0.09793 -0.11293 -0.12768 -0.14107 -0.15186 -0.15904 -0.16192 482

-0.15993 -0.15275 -0.14079 -0.12427 -0.10463 -0.08298 -0.06051 -0.03876 483

-0.01749 0.00269 0.02259 0.04283 0.06301 0.08345 0.10238 0.11881 484 0.13079 0.13650 0.13565 0.12727 0.11327 0.09465 0.07398 0.05385 485 0.03484 0.01885 0.00412 -0.01022 -0.02522 -0.04294 -0.06195 -0.08241 486

-0.10224 -0.11930 -0.13372 -0.14412 -0.15209 -0.15853 -0.16381 -0.16926 487

-0.17314 -0.17495

-0.17264 -0.16442 -0.14994 -0.12801 -0.10092 -0.06977 488

-0.03762 -0.00750 0.01997 0.04253 0.06264 0.08122 0.10029 0.12252 489 0.14612 0.17137 0.19407 0.21096 0.21956 0.21642 0.20288 0.17889 490 0.14842 0.11493 0.08213 0.05427 0.03244 0.01876 0.01139 0.00905 491 0.00921 0.00868 0.00661 0.00104 -0.00735 -0.01819 -0'.03044 -0.04273 492

-0.05425 -0.06391 -0.07157 -0.07689 -0.08065 -0.08331 -0.08594 -0.08985 493

-0.09489 -0.10176 -0.10961 -0.11778 -0.12623 -0.13422 -0.14267 -0.15191 494

-0.16240 -0.17486 -0.18841 -0.20288 -0.21667 -0.22847 -0.23749 -0.24262 495

-0.24439 -0.24281 -0.23969 -0.23637 -0.23413 -0.23463 -0.23708 -0.24164 496

-0.24611 -0.24860 -0.24784 -0.24189 -0.23105 -0.21525 -0.19526 -0.17228 497

-0.14723 -0.12140 -0.09600 -0.07214 -0.05104 -0.033?3 -0.02045 -0.01156 498

-0.00630 -0.00406 -0.00359.-0.00372 -0.00356 -0.00188 0.00099 0.00544 499 0.01060 0.01569 0.02130 0.02680 0.03449 0.04559 0.06109 0.08290 500 0.10871 0.13782 0.16757 0.19489 0.21994 0.24101 0.26000 0.27834 501 0.29615 0.31497 0.33302 0.34959 0.36316 0.37187 0.37602 0.37486 502 0.37003 0.36265 0.35407 0.34606 0.33841 0.33184 0.32482 0.31622 503 0.30509 0.28978 0.27119 0.24919 0.22535 0.20119 0.17718 0.15445 504

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 139 of 196 Date: 11/06/02 0.13258 0.11146 0.09045 0.06888 0.04629 0.02216 -0.00301 -0.02925 505

-0.05474 -0.07825 -0.09850 -0.11377 -0.12487 -0.13162 -0.13581 -0.13925 506

-0.14223 -0.14615 -0.14994 -0.15315 -0.15514 -0.15465 -0.15228 -0.14785 507

-0.14219 -0.13600 -0.12967 -0.12376 -0.11767 -0.11137 -0.10327 -0.09234 508

-0.07764 -0.05788 -0.03438 -0.00735 0.02054 0.04702 0.07085 0.08976 509 0.10491 0.11626 0.12547 0.13431 0.14261 0.15139 0.15855 0.16295 510 0.16284 0.15606 0.14349 0.12455 0.10234 0.07909 0.05688 0,03879 511 0.02396 0.01281 0.00364 -0.00563 -0.01541 -0.02720 -0.04083 -0.05593 512

-0.07285 -0.09094 -0.10965 -0.12867 -0.14514 -0.15751 -0.16284 -0.15842 513

-0.14459 -0.12051 -0.08947 -0.05400 -0.01714 0.01736 0.04881 0.07540 514 0.09839 0.11855 0.13758 0.15751 0.17882 0.20266 0.22779 0.25346 515 0.27773 0.29844 0.31452 0.32429 0.32771 0.32466 0.31574 0.30178 516 0.28385 0.26317 0.24104 0.21867 0.19694 0.17678 0.15813 0.14099 517 0.12472 0.10868 0.09213 0.07437 0.05492 0.03332 0.01005 -0.01494 518

-0.03997 -0.06400 -0.08593 -0.10433 -0.12025 -0.13360 -0.14659 -0.16090 519

-0.17701 -0.19642 -0.21676 -0.23702 -0.25401 -0.26469 -0.26839 -0.26308 520

-0.25129 -0.23433 -0.21493 -0.19650 -0.17893 -0.16396 -0.14944 -0.13379 521

-0.11635 -0.09486 -0.07110 -0.04545 -0.01917 0.00552 0.02993 0.05348 522 0.07751 0.10341 0.12948 0.15589 0.17892 0.19598 0.20518 0.20379 523 0.19405 0.17652 0.15581 0.13596 0.11992 0.11175 0.11071 0.11738 524 0.12892 0.14229 0.15563 0.16561 0.17181 0.17321 0.16934 0.16067 525 0.14648 0.12710 0.10316 0.07501 0.04550 0.01645 -0.00881 -0.02737 526

-0.03787 -0.03841 -0.03061 -0.01521 0.00451 0.02544 0.04545 0.06154 527 0.07424 0.08294 0.08974 0.09665 0.10451 0.11541 0.12814 0.14240 528 0.15702 0.17016 0.18214 0.19203 0.20043 0.20783 0.21332 0.21710 529 0.21725 0.21259 0.20237 0.18530 0.16327 0.13698 0.10950 0.08349 530 0.06039 0.04259 0.02875 0.01865 0.01004 0.00048 -0.01059 -0.02493 531

-0.04126 -0.05904 -0.07680 -0.09266 -0.10640 -0.11702 -0.12511 -0.13118 532

-0.13576 -0.13983 -0.14374 -0.14806 -0.15305 -0.15883 -0.16541 -0.17268 533

-0.18012 -0.18745 -0.19352 -0.19761 -0.19896 -0.19680 -0.19162 -0.18339 534

-0.17373 -0.16392 -0.15492 -0.14825 -0.14328 -0.14011 -0.13770 -0.13493 535

-0.13171 -0.12718 -0.12221 -0.11735 -0.11309 -0.11026 -0.10854 -0.10809 536

-0.10793 -0.10734 -0.10556 -0.10174 -0.09593 -0.08783 -0.07835 -0.06809 537

-0.05798 -0.04913 -0.04140 -0.03534 -0.02995 -0.02466 -0.01902 -0.01224 538

-0.00533 0.00143 0.00635 0.00795 0.00558 -0.00196 -0.01368 -0.02924 539

-0.04688 -0.06498 -0.08244 -0.09770 -0.11119 -0.12267 -0.13348 -0.14473 540

-0.15701 -0.17150 -0.18698 -0.20311 -0.21785 -0.22940 -0.23687 -0.23871 541

-0.23579 -0.22848 -0.21822 -0.20675 -0.19503 -0.18458 -0.17581 -0.16927 542

-0.16524 -0.16368 -0.16475 -0.16829 -0.17402 -0.18180 -0.19082 -0.20060 543

-0.21034 -0.21929 -0.22744 -0.23426 -0.24060 -0.24693 -0.25338 -0.26070 544

-0.26758 -0.27357 -0.27742 -0.27752 -0.27451 -0.26779 -0.25864 -0.24813 545

-0.23564 -0.22211 -0.20495 -0.18290 -0.15499 -0.11940 -0.07920 -0.03538 546 0.00739 0.04496 0.07602 0.09739 0.11216 0.12159 0.12942 0.13978 547 0.15293 0.17118 0.19142 0.21170 0.22920 0.24029 0.24499 0.24181 548 0.23316 0.22092 0.20749 0.19581 0.18689 0.18245 0.18169 0.18429 549 0.18872 0.19327 0.19719 0.19882 0.19915 0.19806 0.19659 0.19592 550 0.19491 0.19392 0.18996 0.18113 0.16606 0.14242 0.11258 0.07718 551 0.03996 0.00468 -0.02740 -0.05319 -0.07408 -0.09037 -0.10288 -0.11375 552

-0.12133 -0.12583 -0.12562 -0.11899 -0.10698 -0.08908 -0.06817 -0.04636

-0.02542 -0.00803 0.00660 0.01811 0.02824 0.03866 0.05036 0.06483 0.08174 0.10106 0.12122 0.14080 0.15763 0.16967 0.17552 0.17361 0.16463 0.14879 0.12842 0.10558 0.08268 0.06220 0.04533 0.03357 0.02616 0.02281 0.02161 0.02084 0.01921 0.01491 0.00884 0.00085

-0.00666 -0.01177 -0.01321 -0.00892 -0.00024 0.01262 0;02714 0.04090 0.05262 0.06012 0.06415 0.06459 0.06307 0.06119 0.05966 0.05995 0.06117 0.06324 0.06464 0.06390 0.06069 0.05390 0.04488 0.03423 0.02373 0.01512 0.00911 0.00693 0.00769 0.01105 0.01531 0.01890 0.02092 0.02002 0.01703 0.01199 0.00711 0.00401 0.00415 0.00936 0.01869 0.03210 0;04685 0.06067 0.07134 0.07607 0.07495 0.06709 0.05420 0.03776 0.01923 0.00081 -0.01731 -0.03432 -0.05037 -0.06614

-0.08122 -0.09612 -0.11107 -0.12576 -0.14214 -0.16044 -0.18198 -0.20791

-0.23504 -0.26265 -0.28390 -0.29415 -0.28986 -0.26600 -0.22725 -0.17479

-0.11725 -0.06248 -0.01456 0.01937 0.04275 0.05598 0.06487 0.07572 0.09049 0.11395 0.14346 0.17793 0.21372 0.24622 0.27367 0.29275 0.30361 0.30610 0.30116 0.29042 0.27536 0.25778 0.23966 0.22263 0.20816 0.19760 0.19059 0.18729 0.18607 0.18548 0.18445 0.18136 0.17663 0.16996 0.16239 0.15491 0.14772 0.14172 0.13597 0.13012 0.12311 0.11370 0.10207 0.08754 0.07117 0.05371 0.03548 0.01766

-0.00064 -0.01947 -0.03902 -0.06001 -0.08076 -0.10078 -0.11801 -0.13055

-0.13830 -0.14024 -0.13822 -0.13343 -0.12785 -0.12374 -0.12143 -0.12215

-0.12465 -0.12825 -0.13160 -0.13307 -0.13279 -0.13001 -0.12625 -0.12256

-0.12004 -0.12040 -0.12309 -0.12843 -0.13519 -0.14211 -0.14861 -0.15342

-0.15674 -0.15838 -0.15845 -0.15742 -0.15497 -0.15129 -0.14626 -0.13975 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577

Calc Number: GEO.HBIP.02.06 Rev Nunber: 0 Sheet Number: 140 of 196 Date: 11/06/02

-0.13222

-0.06956 0.01293

-0.06125 0.02115 0.09024 0.03074

-0.18221

-0.30122

-0.17431 0.02209 0.04172

-0.05860

-0.19514 0.03968 0.18255 0.07983 0.03483 0.08143 0.21745 0.06173

-0.19413

-0.15899 0.05143 0.09095

-0.05099

-0.30560

-0.21328 0.22530 0.56119 0.40397

-0.05683

-0.38629

-0.24668 0.06399 0.18421 0.04037 0.15642 0.31172 0.22691 0.17732 0.20756 0.17529 0.07288

-0.17509

-0.41116

-0.45264

-0.30314

-0.00805

-0.02156

-0.19704

-0.14039 0.27952 0.24780 0.10572

-0.09007

-0.26274

-0.25969

-0.15427 0.14973 0.20873 0.10291 0.12234 0.21228 0.28350 0.25780

-0.04429

-0.46911

-0.34255 0.04538 0.34400 0.27787 0.09351

-0.12380 -0.11515

-0.05950 -0.04756 0.00639 -0.00508

-0.05384 -0.04297 0.03063 0.04036 0.09348 0.09440 0.00748 -0.01790

-0.21117 -0.23895

-0.28860 -0.27245

-0.15706 -0.13751 0.04344 0.05933 0.03158 0.02169

-0.07992 -0.10227

-0.19325 -0.18289 0.08319 0.12128 0.17361 0.16297 0.06084 0.04345 0.04284 0.05021 0.09164 0.10466 0.22761 0.22908 0.02809 -0.00388

-0.21827 -0.23393

-0.14259 -0.12598 0.08333 0.10794 0.08400 0.07744

-0.08956 -0.12815

-0.33101 -0.35119

-0.14921 -0.08297 0.26950 0.31426 0.58613 0.60108 0.33298 0.26087

-0.09627 -0.13579

-0.41680 -0.43567

-0.19309 -0.14311 0.09729 0.12954 0.16318 0.13847 0.03736 0.03908 0.18554 0.21328 0.31611 0.31556 0.21350 0.20344 0.17195 0.16776 0.21902 0.22739 0.15925 0.14457 0.05313 0.02917

-0.20936 -0.24191

-0.43602 -0.45741

-0.43301 -0.41272

-0.27232 -0.23576 0.00821 0.01699

-0.03771 -0.05648

-0.21442 -0.22683

-0.09421 -0.04117 0.30882 0.32654 0.22692 0.20752 0.08964 0.07289

-0.12940 -0.16750

-0.25798 -0.25177

-0.26916 -0.27687

-0.10113 -0.04603 0.15657 0.16093 0.21221 0.21019 0.08793 0.07847 0.13367 0.14412 0.22729 0.24146 0.28901 0.29249 0.24729 0.23177

-0.10581 -0.16495

-0.51738 -0.55432

-0.27059 -0.20414 0.09242 0.14362 0.33936 0.32847 0.27355 0.26489 0.07294 0.06308 5-0.10675

-0. 03336 8 -0.0203E 7 -0.03084 6 0.05061 0.0928!

-0.04431 S -0.26467

-0.25507

-0.11470 0.06849 0.01250

-0.12416

-0.16291 0.15144 0.15239 0.02981 0.05552 0.12024 0.21912

-0.03401

-0.23747

-0.10769 0.12113

0. 07016

-0.16321

-0.36341

-0.02035 0.35989 0.60421 0.19287

-0.17663

-0.43894

-0.10031 0.15908 0.11393 0.04569 0.23758 0.30904 0.19723 0.16613 0.23056 0.13233 0.00084

-0.27243

-0.47397

-0.39439

-0.19353 0.01955

-0.07818

-0.23333 0.01661 0.33178 0.18967 0.05525

-0.20144

-0.24655

-0.28078 0.00619 0.16564 0.20100 0.07565 0.15356 0.25114 0.29238 0.20843

-0.21831

-0.57273

-0.14909 0.19857 0.31586 0.24795 0.06651

-0.09885

-0.01873 3 -0.03638

-0.01827 10.06076 50.08811

-0.07150

-0.28599

-0.23738 p -0.08916 0.07156 0.00275

-0.14499

-0.13409 0.17322 0.14095 0.02076 0.05974 0.13848 0.19951

-0.06411

-0.23173

-0.08567 0.12531 0.05939

-0.19581

-0.36379

0. 03815 0.40554 0.59329 0.13018

-0.21893

-0.42658

-0.06287 0.18293 0.09091 0.05778 0.25881 0.29763 0.19323 0.16776 0.22844 0.12158

-0.03107

-0.30158

-0.48420

-0.37726

-0.14914 0.01703

-0.10185

-0.23252 0.07643 0.32666 0.17293 0.03484

-0.22936

-0.24325

-0.27727 0.05283 0.17157 0.18612 0.07851 0.16273 0.25764 0.28962 0.17607

-0.26905-

-0.56916-

-0.10296-0.25053 0.30344 0.22396 0.07905

-0.09174

-0.00466

-0.05007

-0.0071!

0.07011 0.0796!

-0.09853

-0.30084

-0.22094

-0.06110 0.06875

-0.00876

-0.16358

-0.09670 0.18592 0.12851 0.01815 0.06356 0.15902 0.17035

-0.09657

-0.21719

-0.05660 0.12073 0.04156

-0.22489

-0.34809

0. 09011 0.44962 0.56646 0.07537

-0.26232

-0.39693

-0.02983 0.19801 0.07220 0.07621 0.27667 0.28137 0.19004 0.17362 0.22030 0.11162

-0.06586

-0.32980

-0.48652

-0.36203

-0.10563 0.01138

-0.12691

-0.22360 0.13531 0.31256 0.15589 0.01033

-0.24876

-0.24279

-0.26331 0.09025 0.18034 0.16646 0.08638 0.17123 0.26393 0.28332 0.13172

-0.31775

_0.53717

-0.06459 0.29285 0.29308 0.19235

0. 09876 1 -0.08473 0.00646 7 -0.05986 S0.00308 1 0.07849 50.06733

-0.12599

-0.30871

-0.20520 p -0.03217 i 0.06184

-0.02239

-0.17881 P -0.05351 0.19084 0.11449 0.02033 0.06773 0.18008 0.13560

-0.12948

-0.19800

-0.02320 0.11134 0.01741

-0.25230

-0.31741 0.13751 0.49139 0.52505 0.02690

-0.30599

-0.35441 0.00093 0.20369 0.05746 0.09945 0.29125 0.26287 0.18690 0.18278 0.20778 0.10111

-0.10222

-0.35736

-0.48169

-0.34589

-0.06576-0.00270 -

-0.15204-

-0.20552-0.19048 0.29276 0.13922

-0.01859-

-0.26038-

-0.24565-

-0.23832-0.11870 0.19031 0.14441 0.09745 0.18068 0.27029 0.27540 0.07885

-0.36655

-0.48533

-0.02969 0.32417 0.28544 0.15768 0.11971

-0.07771 0.01253

-0.06328 0.01231 0.08520 0.05079

-0.15393

-0.30828

-0.19001

-0.00377 0.05239

-0. 03929

-0.18998

-0.00699 0.18902 0.09776 0.02654 0.07360 0.20077 0.09878

-0.16349

-0.17849 0.01449 0.10109

-0.01453

-0.27963

-0.27073

0. 18217 0.52919 0.46926

-0.01663

-0.34861

-0.30246 0.03227 0.19825 0.04676 0.12697 0.30338 0.24414 0.18235 0.19485 0.19217 0.08848

-0.13897

-0.38481

-0.46950

-0.32685

-0.03314

-0.00818

-0.17578

-0.17762 0.23941 0.27064 0.12239

-0.05275

-0.26433 0.25158 0.20081 0.13781 0.20059 0.12252 0.10973 0.19575 0.27716 0.26743 0.01875 0.41867 0.41757 0.00610 0.33983 0.28139 0.12330 0.13584 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 141 of 196 Date: 11/06/02 0.14604 0.14488 0.13466 0.11936 0.10378 0.09265 0.08749 0.09173 651 0.10497 0.12573 0.14808 0.16693 0.18187 0.18985 0.19305 0.19317 652 0.19139 0.19041 0.19025 0.19165 0.19493 0.19985 0.20648 0.21445 653 0.22306 0.23188 0.23976 0.24586 0.24975 0.25069 0.24966 0.24677 654 0.24344 0.24092 0.23869 0.23737 0.23436 0.22801 0.21657 0.19772 655 0.17264 0.14100 0.10580 0.06947 0.03366 0.00114 -0.02938 -0.05747 656

-0.08548 -0.11538 -0.14690 -0.18155 -0.21513 -0.24562 -0.26889 -0.28057 657

-0.28120 -0.26905 -0.24882 -0.22397 -0.19850 -0.17767 -0.16161 -0.15219 658

-0.14683 -0.14388 -0.14132 -0.13591 -0.12768 -0.11564 -0.10176 -0.08770 659

-0.07563 -0.06825 -0.06647 -0.07178 -0.08388 -0.10241 -0.12633 -0.15429 660

-0.18455 -0.21551 -0.24525 -0.27206 -0.29522 -0.31368 -0.32836 -0.33980 661

-0.34924 -0.35808 -0.36681 -0.37641 -0.38615 -0.39580 -0.40415 -0.40993 662

-0.41241 -0.41053 -0.40451 -0.39432 -0.38135 -0.36674 -0.35072 -0.33421 663

-0.31689 -0.29901 -0.28028 -0.26032 -0.23996 -0.21943 -0.20033 -0.18337 664

-0.17139 -0.16426 -0.16210 -0.16503 -0.17152 -0.18032 -0.18962 -0.19751 665

-0.20314 -0.20536 -0.20449 -0.20066 -0.19485 -0.18804 -0.18102 -0.17473 666

-0.16899 -0.16391 -0.15819 -0.15096 -0.14069 -0.12592 -0.10614 -0.08052 667

-0.05015 -0.01570 0.02103 0.05819 0.09470 0.12902 0.16123 0.19102 668 0.21915 0.24629 0.27318 0.30064 0.32852 0.35696 0.38452 0.41018 669 0.43219 0.44890 0.46017 0.46479 0.46322 0.45735 0.45032 0.44213 670 0.42969 0.41252 0.39126 0.36743 0.34295 0.31913 0.29712 0.27652 671 0.25667 0.23707 0.21792 0.19995 0.18313 0.16775 0.15340 0.13884 672 0.12384 0.10798 0.09147 0.07433 0.05688 0.04032 0.02376 0.00686 673

-0.01091 -0.03037 -0.04993 -0.06910 -0.08521 -0.09618 -0.10075 -0.09706 674

-0.08663 -0.06997 -0.05001 -0.02950 -0.01028 0.00492 0.01657 0.02414 675 0.02907 0.03298 0.03623 0.04019 0.04419 0.04788 0.05102 0.05262 676 0.05299 0.05199 0.04924 0.04493 0.03806 0.02915 0.01520 -0.00124 677

-0.01965 -0.03912 -0.05809 -0.07484 -0.08902 -0.09962 -0.10736 -0.11269 678

-0.11609 -0.11853 -0.11959 -0.11949 -0.11762 -0.11342 -0.10707 -0.09830 679

-0.08794 -0.07661 -0.06518 -0.05472 -0.04562 -0.03856 -0.03359 -0.03073 680

-0.03003 -0.03131 -0.03449 -0.03949 -0.04580 -0.05319 -0.06101 -0.06873 681

-0.07626 -0.08324 -0.09014 -0.09716 -0.10455 -0.11267 -0.12107 -0.12963 682

-0.13714 -0.14283 -0.14549 -0.14412 -0.13867 -0.12870 -0.11551 -0.10003 683

-0.08423 -0.07027 -0.05915 -0.05231 -0.04956 -0.05088 -0.05554 -0.06256 684

-0.07094 -0.07960 -0.08752 -0.09382 -0.09799 -0.09973 -0.09953 -0.09774 685

-0.09567 -0.09431 -0.09502 -0.09899 -0.10627 -0.11732 -0.13042 -0.14449 686

-0.15730 -0.16671 -0.17182 -0.17116 -0.16568 -0.15590 -0.14325 -0.12945 687

-0.11527 -0.10195 -0.08950 -0.07811 -0.06739 -0.05702 -0.04643 -0.03518 688

-0.02330 -0.01055 0.00182 0.01321 0.02191 0.02647 0.02660 0.02112 689 0.01240 0.00199 -0.00838 -0.01645 -0.02210 -0.02436 -0.02504 -0.02561 690

-0.02692 -0.03054 -0.03587 -0.04306 -0.05110 -0.05896 -0.06636 -0.07238 691

-0.07781 -0.08298 -0.08846 -0.09505 -0.10275 -0.11210 -0.12252 -0.13332 692

-0.14389 -0.15342 -0.16161 -0.16812 -0.17237 -0.17418 -0.17328 -0.16944 693

-0.16335 -0.15526 -0.14636 -0.13770 -0.12967 -0.12313 -0.11746 -0.11233 694

-0.10723 -0.10136 -0.09472 -0.08702 -0.07836 -0.06896 -0.05867 -0.04766 695

-0.03586 -0.02331 -0.01022 0.00327 0.01670 0.02976 0.04196 0.05282 696 0.06228 D.07001 0.07647 0.08186 0.08643 0.09068 0.09406 0.09645 697 0.09720 0.09560 0.09162 0.08488 0.07567 0.06433 0.05086 0.03571 698 0.01892 0.00054 -0.01846 -0.03770 -0.05597 -0.07231 -0.08636 -0.09746 699

-0.10649 -0.11378 -0.12054 -0.12793 -0.13608 -0.14566 -0.15529 -0.16427 700

-0.17087 -0.17340 -0.17154 -0.16429 -0.15308 -0.13881 -0.12324 -0.10836 701

-0.09472 -0.08358 -0.07449 -0.06717 -0.06115 -0.05552 -0.05011 -0.04448 702

-0.03828 -0.03134 -0.02337 -0.01418 -0.00396 0.00723 0.01894 0.03073 703 0.04229 0.05310 0.06320 0.07235 0.08066 0.08822 0.09470 0.10017 704 0.10380 0.10509 0.10371 0.09908 0.09195 0.08252 0.07209 0.06177 705 0.05199 0.04366 0.03595 0.02862 0.02062 0.01092 -0.00035 -0.01363 706

-0.02741 -0.04075 -0.05178 -0.05874 -0.06094 -0.05723 -0.04876 -0.03612 707

-0.02135 -0.00645 0.00738 0.01848 0.02722 0.03352 0.03886 0.04453 708 0.05201 0.06275 0.07714 0.09574 0.11713 0.14042 0.16286 0.18215 709 0.19642 0.20338 0.20381 0.19762 0.18748 0.17558 0.16431 0.15656 710 0.15248 0.15312 0.15688 0.16242 0.16808 0.17168 0.17277 0.17019 711 0.16481 0.15708 0.14824 0.13973 0.13196 0.12596 0.12113 0.11715 712 0.11360 0.10956 0.10539 0.10085 0.09634 0.09232 0.08844 0.08484 713 0.08089 0.07614 0.07053 0.06375 0.05650 0.04910 0.04269 0.03825 714 0.03652 0.03825 0.04290 0.05044 0.05973 0.06955 0.07948 0.08840 715 0.09650 0.10353 0.10909 0.11350 0.11559 0.11478 0.11075 0.10278 716 0.09211 0.07929 0.06603 0.05409 0.04367 0.03571 0.02912 0.02341 717 0.01765 0.01061 0.00304 -0.00531 -0.01233 -0.01662 -0.01676 -0.01090 718

-0.00004 0.01587 0.03451 0.05372 0.07225 0.08791 0.10130 0.11223 719 0.12188 0.13151 0.14143 0.15263 0.16459 0.17709 0.18967 0.20148 720 0.21241 0.22189 0.23002 0.23678 0.24205 0.24600 0.24834 0.24901 721 0.24780 0.24443 0.23956 0.23325 0.22666 0.22061 0.21541 0.21183 722 0.20865 0.20534 0.20071 0.19336 0.18371 0.17129 0.15755 0.14356 723

0.1304!

0.08391 0.00795

-0.04519

-0.08313

-0.13980

-0.18525

-0.17937

-0.08796 0.05493 0.09167 0.05450 0.07454 0.08835

-0.00399

-0.05524

0. 00819
0. 02992

-0.04306

-0.10953

-0.12719

-0.13127

-0.07870

-0.01208 0.05287

0. 04939 0.04962 0.06652 0.04005 0.00837

-0.04144

-0.11381

-0.20853

-0.20229

-0.09598

0. 05090 0.09971 0.14733 0.18113 0.11349
0. 01000

-0.09865

-0.15315

-0.13899

-0.10948

-0.09496

-0.03142

0. 01122 0.03693 0.09499 0.12657 0.13247 0.10519 0.1.0448 0.13277 0.05657

-0.07896

-0.21753

-0.18021

-0.10717

-0.10213

-0.08775

-0.05899

-0.00239 0.07236 0.13665 0.17020 0.11416

-0. 00597

-0.05561

-0.12939

-0.17530

-0.08231 50.11962 1 0.07589 9-0.00160 I -0.04850 l -0.08813

-0.14968

-0.18883

-0.16975

-0.06598 30.06057 0.08915 0.05363 0.07957

0.08059

-0.01497

-0.05013

0. 01471 0.02161

-0.05093

-0.11435

-0.12646

-0.13315

-0.06448

-0. 00641

0. 05670 0.04925 0.05164 0.06339 0.03890

-0.00045

-0. 04450

-0.12937

-0.21632

-0.18998

-0.07722 0.06135 0.10564 0.15166 0.18090 0.10069

-0.00584

-0.10529

-0.15795

-0.13524

-0.10685

-0.08839

-0.02422 0.01384 0.04200 0.10106 0.13250 0.12489 0.10313 0.10889 0.13323 0.03901

-0.09645

-0.22749

-0.17040

-0.09693

-0.10565

-0.08421

-0.05320 0.00663 0.08100 0.14337 0.16818 0.10124

-0.01734-

-0.06345

-0.13632

-0.17384

-0.07386 0.11107 0.10526 0.06661 0.0566E

-0.01077 -0.01931

-0.05204 -0.05623

-0.09315 -0.09823

-0.15865 -0.16576

-0.19217 -0.19515

-0.15954 -0.15015

-0.04214 -0.01791 0.06539 0.07101 0.08443 0.07799 0.05392 0.05492 0.08433 0.08852 0.07045 0.05831

-0.02526 -0.03505

-0.04255 -0.03308 0.02100 0.02761 0.01161

-0.05914

-0.11804

-0.12552

-0.13347

-0.05143 0.00047 0.05828 0.04935 0.05446 0.05918 0.03763

-0.00925

-0.04845

-0.14445

-0.22266

-0.17704

-0.05705 0.06955 0.11202 0.15593 0.17795 0.08819

-0.02210

-0.11116

-0.16046

-0.13177

-0.10502

-0.08059

-0.01739 0.01623 0.04793 0.10590 0.13831 0.11773 0.10071 0.11347 0.13133 0.02164

-0.11426

-0.23265

-0.16182

-0.08885

-0.10731

-0.08112

-0.04697 0.01597 0.08943 0.14966 0.16450 0.08708

-0.02635

-0.07259

-0.14279

-0.16820

-0.06827 0.00112

-0.06819

-0.12100

-0.12464

-0. 13138

-0.04082

0. 00887
0. 05758
0. 04915
0. 05809
0. 05455 0.03586

-0.01730

-0.05396

-0.15806

-0.22712

-0.16472

-0.03610 0.07582 0.11860 0.16033 0.17168 0.07604

-0.03838

-0.11701

-0.15988

-0.12820

-0.10425

-0.07209

-0. 01088 0.01873 0.05485 0.10927 0.14329 0.11247 0.09815 0.11744 0.12615 0.00497

-0.13215

-0.23179

-0.15445

-0.08458

-0.10673

-0.07849

-0.04061 0.02546 0.09770 0.15557 0.15931 0.07179

-0.03272

-0.08261

-0.14903

-0.15739

-0.06489 60.1011' 30.0463E

-0. 02695

-0.0609!

-0.1040!

-0.17142

-0.1968C

-0. 1405X 0.00473 0.07677

0. 0709E 0.05694 0.0918C 0.04512

-0.04353

-0.02297 0.03312

-0.00934

-0.07750

-0.12323

-0.12428

-0.12643

-0.03234 0.01826 0.05562 0.04889 0.06179 0.05000 0.03313

-0.02437

-0.06150

-0.17037

-0.22887

-0.15240

-0.01526

0. 08086 0.12518 0.16494 0.16280 0.06393

-0.05391

-0.12323

-0.15718

-0.12458

-0.10386

-0.06323

-0. 00492 0.02140 0.06246 0.11197 0.14647 0.10881 0.09624 0.12117 0.11774

-0.01138

-0.15031

-0.22620

-0.14716

-0.08363

-0.10437

-0.07584

-0.03390 0.03505 0.10582 0.16084 0.15272 0.05576

-0.03741

-0.09302

-0.15524

-0.14318

-0.06277 3 0.09789 8 0.03658 9 -0.03307 5 -0.06631 S-0.11128

-0.17564

-0.19629 7-0.13118 30.02316 70.08278 B0.06484 10.06020 00.09421 0.03195

-0.05050

-0.01385 0.03673

-0.01880 I -0.08682

-0.12515

-0.12496

-0.11801

-0.02606 0.02825 0.05336 0.04848 0.06509 0.04631 0.02907

-0.03015

-0.07172

-0.18123

-0.22703

-0.14020 0.00437 0.08529 0.13140 0.16999 0.15184 0.05158

-0.06797

-0.13057

-0.15297

-0.12065

-0.10348

-0.05475 0.00003 0.02453 0.07076 0.11452 0.14684 0.10717 0.09604 0.12465 0.10567

-0.02787

-0.16879

-0.21642

-0.13874

-0.08637

-0.10074

-0.07267

-0.02678 0.04467 0.11393 0.16535 0.14499 0.03925

-0.04110 -

-0.10318 -

-0.16186 -

-0.12653 -

-0.06049 -

0.

0.

-0.

-0.

-0.

-0.

-0.

-0.

0.

0.

0.

0.

0.

-0.

-0.

-0.

-0.

-0.

-0.

-0.

-0.

-0.

-0.

0.

0.

0.

0.

0.

-0.

-0.

-0.~

-O.

-O.:

-0.:

0.'

0.:

0.:

0.:

0.I

-0.I

-O.:

-O.:

-0.

-0.

-0.(

O.c 0.-

0.-

0.2 0.2 0.2 0.3 O.C

.0C

-0.1

-O.1

  • 0.C

-0.1

-O.:

-0.0

-0.0

-O.:

0.1 0.1 0.1 0.0 0.0

  • 0.1

-0.1

-0.1 0.0 Calc Number. GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 142 of 196 Date: 11/06/02

.09459 0.08994 724

.02691 0.01738 725

.03800 -0.04187 726

.07194 -0.07760 727

.11968 -0.12954 728

.17902 -0.18219 729

.19343 -0.18739 730

.12003 -0.10559 731 03781 0.04787 732

.08789 0.09093 733 05972 0.05640 734 06431 0.06925 735 09476 0.09288 736 01908 0.00727 737 05524 -0.05684 738 00543 0.00169 739 03783 0.03534 740 02751 -0.03544 741 09560 -0.10316 742 12647 -0.12714 743 12646 -0.12885 744 10684 -0.09326 745 02113 -0.01670 746 03788 0.04630 747 05119 0.05000 748 04830 0.04860 749 06732 0.06774 750 04341 0.04142 751 02360 0.01651 752 03475 -0.03834 753 08409 -0.09844 754 19102 -0.20018 755 22192 -0.21325 756 12720 -0.11246 757 02230 0.03785 758 08963 0.09442 759 13721 0.14248 760 17471 0.17875 761 13946 0.12657 762 03866 0.02478 763 28027 -0.09036 764 13829 -0.14622 765 14796 -0.14337 766 L1672 -0.11287 767 L0230 -0.09950 768

)4653 -0.03878 769

)0428 0.00800 770 02819 0.03230 771

)7920 0.08748 772

.1750 0.12159 773

.4463 0.13938 774

.0655 0.10600 775 09727 0.10035 776

.2778 0.13080 777 D9095 0.07428 778 14444 -0.06155 779

.8660 -0.20347 780

.0441 -0.19208 781

.2935 -0.11829 782 19123 -0.09682 783 i9637 -0.09196 784 16894 -0.06430 785 11921 -0.01104 786 5417 0.06339 787 2186 0.12942 788 6863 0.17026 789 3598 0.12572 790 2307 0.00772 791 4476 -0.04956 792 1281 -0.12152 793 6782 -0.17286 794 0958 -0.09470 795 5788 -0.05432 796

Caic Number: GEO.HBIP.02.06

-0.05014 -0.04551

-0.02783 -0.02099 0.08042 0.07719

-0.00643 -0.01140

-0.01573 -0.01440

-0.02421 -0.02359 0.00931 0.01120

-0.01604 -0.02094

-0.03926 -0.04458

-0.08534 -0.08821

-0.04599 -0.03493

-0.02193 -0.02911

-0.04094 -0.03004 0.03469 0.04081 0.02899 0.02134 0.03111 0.02919

-0.02401 -0.02464 0.00352 0.01172 0.01236 -0.00251

-0.05123 -0.04734 0.05390 0.07307 0.10573 0.10048 0.07114 0.06986 0.09504 0.10039 0.13907 0.14172 0.10658 0.09820 0.04460 0.04711 0.07183 0.06330 0.00553 0.00151 0.00187 0.00237

-0.04262 -0.05086

-0.08339 -0.08643

-0.12070 -0.12499

-0.10312 -0.09522

-0.07086 -0.07388

-0.10756 -0.11012

-0.09849 -0.09494

-0.04228 -0.03059 0.05218 0.05810 0.04450 0.04603 0.06516 0.06281 0.02702 0.02485 0.03983 0.03896 0.01462 0.01633 0.04059 0.03758 0.01668 0.01687 0.03611 0.04437 0.07814 0.07723 0.07388 0.07164 0.06051 0.05977 0.03413 0.02711

-0.04187 -0.04830

-0.06518 -0.06503

-0.01335 -0.00951

-0.00769 -0.00521

-0.00227 0.00217 0.04380 0.04512 0.04516 0.04129 0.01295 0.01340 0.02812 0.02901 0.04058 0.04187 0.00507 -0.00413

-0.02621 -0.02593

-0.04797 -0.05096

-0.03715 -0.03464

-0.06472 -0.07057

-0.07332 -0.07015 0.00654 0.01653

-0.00098 -0.00557

-0.00029 0.00480 0.03523 0.03534 0.01851 0.01306 0.01744 0.02251

-0.04108 -0.03733

-0.01007 0.00617 0.06780 0.05373

-0.01458 -0.01710

-0.01372 -0.01431

-0.02127 -0.01705 0.01125 0.00958

-0.02478 -0.02713

-0.05070 -0.05705

-0.08908 -0.08755

-0.02510 -0.01758

-0.03674 -0.04413

-0.01772 0.04590 0.01570 0.02388

-0.02329 0.01996

-0.01801

-0.04091 0.08969 0.09503 0.06999 0.10583 0.14226 0.08927 0.05259 0.05278

-0.00147 0.00116

-0.05817

-0.08982

-0.12770

-0.08759

-0.07803

-0.11139

-0.09079

-0.01825 0.06097 0.04934 0.05898 0.02448 0.03635

0. 01991 0.03320 0.01743 0.05316 0.07620 0.06911 0.05868 0.01903

-0.05304

-0.06275

-0.00809

-0.00318 0.00832 0.04582 0.03634 0.01502 0.02989 0.04201

-0.01231

-0.02635

-0.05262

-0.03378

-0.07507

-0.06521 0.02296

-0.00866 0.01052 0.03467 0.00811 0.02627

-0.00574 0.04978 0.01376 0.01496

-0.02102 0.02771

-0.03161

-0.03191 0.10216 0.09011 0.07185 0.11133 0.13997 0.07939 0.06046 0.04200

-0.00352

-0.00248

-0.06431

-0.09373

-0.12825

-0.08074

-0.08291

-0.11116

-0.08575

-0.00556 0.06029 0.05377 0.05400 0.02599 0.03210 0.02503 0.02826 0.01798 0.06174 0.07601 0.06672 0.05681 0.00962

-0.05607

-0.05741

-0.00889

-0.00262 0.01596 0.04665 0.03073 0.01753 0.03112 0.04051

-0.01868

-0.02806

-0.05274

-0.03521

-0.07765

-0.05779 0.02476

-0.01015 0.01675 0.03377

0. 00446 0.02760

-0.03453 0.02498 0.03760

-0.01854

-0.01582

-0.01161 0.00627

-0.02876

-0.06358

-0.08349

-0.01272

-0.04989 0.00549 0.05136 0.01481 0.00442

-0.01768 0.03314

-0.04271

-0.01997 0.11041 0.08558 0.07503 0.11699 0.13561 0.06951 0.06853 0.03159

-0.00440

-0.00816

-0.06938

-0.09828

-0.12668

-0.07515

-0.08824

-0.10980

-0.07963 0.00731 0.05736

0. 05850 0.04825 0.02879 0.02706 0.03062 0.02351 0.01911 0.06920 0.07610 0.06458 0.05417

-0.00067

-0.05809

-0.04983

-0.01054

-0.00284 0.02395 0.04729 0.02511 0.02038 0.03267 0.03704

-0.02321

-0.03089

-0.05135

-0.03864

-0. 07875

-0.04795 0.02296

-0.01019 0.02273 0.03226 0.00270 0.02668

-0.03318 0.04510 0.02289

-0.01901

-0.01827

-0.00551 0.00152

-0.03019

-0.06987

-0.07674

-0.01104

-0.05314 0.01447 0.04944 0.01906

-0.00583

-0.01395 0.03486

-0.04955

-0.00450 0.11392

0. 08117 0.07928 0.12300 0.12950 0.05970 0.07474 0.02298

-0.00373

-0.01571

-0.07361

-0.10360

-0.12298

-0.07132

-0.09374

-0.10761

-0.07210 0.02016 0.05295 0.06232 0.04208 0.03243 0.02202 0.03580 0.02010 0.02108 0.07443 0.07632 0.06297 0.05044

-0. 01190

-0.06007

-0.03999

-0.01150

-0.00390 0.03116 0.04808 0.02024 0.02303 0.03453 0.03126

-0.02578

-0.03484

-0.04853

-0.04403

-0.07851

-0.03521 0.01819

-0.00929 0.02780 0.03023 0.00371 0.02337

-0.03208 0.06293

0. 00991

-0.01868

-0.02088 0.00052

-0.00407

-0.03200

-0.07574

-0.06786

-0.01228

-0.05305 0.02213 0.04484 0.02431

-0.01483

-0.00925 0.03228

-0.05298 0.01346 0.11373 0.07729 0.08428 0.12888 0.12220 0.05162

0. 07808 0.01581

-0.00221

-0.02444

-0.07716

-0.10930

-0.11749

-0.06929

-0.09899

-0.10482

-0.06331 0.03226 0.04852 0.06499 0.03616 0.03599 0.01780 0.03967 0.01778 0.02435 0.07768 0.07631 Q. 06182 0.04579

-0.02298

-0.06186

-0.02974

-0.01168

-0.00469 0.03723 0.04830 0.01639 0.02534 0.03661 0.02371

-0.02682

-0.03935

-0.04486

-0.05063

-0.07731

-0.02112 0.01174

-0.00723 0.03178 0.02736 0.00680 0.01833 Rev Number. 0 Sheet Number: 143 of 196 Date: 11/06/02

-0.03103 797 0.07492 798 0.00040 799

-0.01731 800

-0.02307 801 0.00557 802

-0.01020 803

-0.03511 804

-0.08110 805

-0.05727 806

-0.01607 807

-0.04867 808 0.02880 809 0.03732 810 0.02879 811

-0.02071 812

-0.00340 813 0.02420 814

-0.05349 815 0.03353 816 0.11063 817 0.07374 818 0.08956 819 0.13454 820 0.11468 821 0.04642 822 0.07681 823 0.01005 824 0.00002 825

-0.03358 826

-0.08036 827

-0.11525 828

-0.11073 829

-0.06923 830

-0.10374 831

-0.10183 832

-0.05332 833 0.04330 834 0.04561 835 0.06593 836 0.03094 837 0.03862 838 0.01523 839 0.04120 840 0.01680 841 0.02946 842 0.07857 843 0.07540 844 0.06111 845 0.04042 846

-0.03315 847

-0.06394 848

-0.02060 849

-0.01007 850

-0.00428 851 0.04124 852 0.04733 853 0.01395 854 0.02694 855 0.03874 856 0.01465 857

-0.02673 858

-0.04390 859

-0.04079 860

-0.05779 861

-0.07577 862

-0.00663 863 0.00515 864

-0.00427 865 0.03411 866 0.02327 867 0.01180 868 0.01228 869

Caic Number: GEO.HBIP.02.06 0.00579 -0.00033

-0.01357 -0.01175

-0.03404 -0.03993

-0.03643 -0.03683

-0.05401 -0.05362

-0.03849 -0.03701

-0.03488 -0.03147 0.04187 0.05163 0.08071 0.08450 0.07960 0.07533 0.07995 0.08477 0.11636 0.11975 0.13449 0.13276 0.07479 0.05720

-0.06016 -0.06563

-0.05558 -0.05347

-0.03961 -0.03108 0.05273 0.05478 0.00401 -0.00046 0.00000 0.00064 0.01379 0.01589 0.03557 0.03736 0.03726 0.03836 0.03712 0.03562 0.05701 0.06570 0.12977 0.13438 0.14916 0.15189 0.13054 0.12102 0.04642 0.04009 0.04831 0.05047 0.04719 0.04601 0.03336 0.03164 0.03099 0.03292 0.03761 0.03649 0.03720 0.04145 0.09438 0.09995 0.09622 0.09059 0.03590 0.02400

-0.03410 -0.03254 0.00009 0.00345 0.00022 -0.00461

-0.05561 -0.06618

-0.12145 -0.12274

-0.10572 -0.10029

-0.07201 -0.07406

-0.11576 -0.12300

-0.15568 -0.15698

-0.14615 -0.14407

-0.15113 -0.15314

-0.17295 -0.17722

-0.18264 -0.18097

-0.17924 -0.17850

-0.12471 -0.11168

-0.05371 -0.05072

-0.03657 -0.03628

-0.04101 -0.04331

-0.05494 -0.05344

-0.04572 -0.04432

-0.03328 -0.03213

-0.03795 -0.03923

-0.00051 0.00872 0.04547 0.04629 0.03724 0.03489 0.01597 0.01508 0.02913 0.02927 0.02424 0.02383 0.00347 0.00229 0.00719 0.00730 0.01852 0.02168 0.03753 0.03822 0.03138 0.02732

-0.00010 -0.00155 0.00250 0.00330

-0.00574 -0.01007

-0.01037 -0.01006

-0.04417 -0.04568

-0.03860 -0.04161

-0.05230 -0.05041

-0.03616 -0.03603

-0.02594 -0.01796 0.05938 0.06472 0.08792 0.09031 0.07179 0.06976 0.08995 0.09526 0.12308 0.12652 0.12974 0.12551 0.03789 0.01744

-0.06797 -0.06796

-0.05196 -0.05106

-0.01994 -0.00634 0.05279 0.04700

-0.00296 -0.00380 0.00143 0.00265 0.01804 0.02032 0.03831 0.03823 0.03961 0.04073 0.03473 0.03496 0.07540 0.08584 0.13763 0.13967 0.15400 0.15472 0.11050 0.09928 0.03610 0.03471 0.05167 0.05185 0.04470 0.04303 0.03017 0.02898 0.03491 0.03664 0.03524 0.03402 0.04714 0.05425 0.10402 0.10655 0.08438 0.07799 0.01156 -0.00090

-0.02896 -0.02410 0.00610 0.00807

-0.01010 -0.01594

-0.07706 -0.08786

-0.12263 -0.12159

-0.09439 -0.08822

-0.07771 -0.08264

-0.12996 -0.13649

-0.15747 -0.15730

-0.14266 -0.14241

-0.15509 -0.15707

-0.18108 -0.18399

-0.17954 -0.17861

-0.17644 -0.17255

-0.09893 -0.08714

-0.04813 -0.04546

-0.03639 -0.03665

-0.04600 -0.04909

-0.05165 -0.05019

-0.04270 -0.04100

-0.03135 -0.03102

-0.03922 -0.03724 0.01737 0.02498 0.04633 0.04575 0.03235 0.02965 0.01536 0.01707 0.02865 0.02751 0.02279 0.02058 0.00218 0.00305 0.00751 0.00816 0.02489 0.02794 0.03860 0.03875 0.02267 0.01763

-0.00236 -0.00271 0.00346 0.00270

-0.01312

-0.01137

-0.04522

-0.04521

-0.04804

-0.03634

-0.00788 0.06852 0.09136 0.06917 0.10041 0.12972 0.11965

-0.00279

-0.06622

-0. 05038 0.00836

0. 03869

-0. 00346 0.00426 0.02290 0.03766 0.04141 0.03645 0.09639 0.14114 0.15383 0.08771 0.03544 0.05130 0.04119 0.02823 0.03800 0.03309 0.06229 0.10745 0.07114

-0.01236

-0.01855 0.00904

-0.02235

-0.09791

-0.11969

-0.08239

-0.08852

-0.14231

-0.15632

-0.14314

-0.15930

-0.18583

-0.17818

-0.16666

-0.07679

-0.04293

-0.03707

-0.05198

-0.04891

-0.03923

-0.03132

-0.03327 0.03145 0.04468 0.02678 0.01962 0.02622 0.01756 0.00441 0.00926 0.03073 0.03851 0.01267

-0.00248 0.00128

-0.01494

-0.01503

-0.04301

-0.04861

-0.04553

-0.03686 0.00419 0.07146 0.09041 0.07013 0.10507 0.13236 0.11206

-0.02160

-0.06375

-0.04980 0.02296 0.02903

-0.00267 0.00644 0.02610 0.03701 0.04127 0.03935 0.10649 0.14254 0.15074 0.07606 0.03795 0.05045 0.03920 0.02799 0.03874 0.03264 0.07089 0.10677 0.06390

-0.02187

-0.01321 0.00872

-0.02933

-0.10656

-0.11728

-0.07739

-0.09487

-0.14709

-0.15436

-0.14474

-0.16197

-0.18632

-0.17824

-0.15864

-0.06847

-0.04065

-0.03755

-0.05422

-0.04811

-0.03763

-0.03237

-0.02702 0.03672 0.04320 0.02370 0.02268 0.02525 0.01365 0.00558 0.01085 0.03308 0.03788 0.00832

-0.00161

-0.00059

-0.01547

-0.02031

-0.04014

-0.05149

-0.04301

-0. 03710 0.01710 0.07409 0.08794 0.07245 0.10931 0.13424 0.10222

-0.03800

-0.06087

-0. 04825 0.03607 0.01925

-0.00162 0.00888 0.02944 0.03654 0.04046 0.04378 0.11569 0.14417 0.14571 0.06498 0.04143 0.04936 0.03716 0.02836 0.03890 0.03303 0.07947 0.10460 0.05578

-0.02895

-0.00815 0.00717

-0.03711

-0.11356

-0.11415

-0.07370

-0.10166

-0.15091

-0.15186

-0.14684

-0.16512

-0.18577

-0.17861

-0.14874

-0.06194

-0.03869

-0.03830

-0.05560

-0.04749

-0.03609

-0.03395

-0.01912 0.04078 0.04143 0.02075 0.02563 0.02456 0.00963 0.00656 0.01297 0.03501 0.03658 0.00464

-0.00038 Rev Number: 0 Sheet Number: 144 of 196 Date: 11/06/02

-0.01488 870

-0.02712 871

-0.03783 872

-0.05328 873

-0.04055 874

-0.03664 875 0.02998 876 0.07728 877 0.08406 878 0.07575 879 0.11297 880 0.13493 881 0.08977 882

-0.05086 883

-0.05806 884

-0.04509 885 0.04621 886 0.01080 887

-0.00077 888 0.01134 889 0.03274 890 0.03666 891 0.03889 892 0.04967 893 0.12349 894 0.14652 895 0.13891 896 0.05488 897 0.04505 898 0.04830 899 0.03521 900 0.02943 901 0.03848 902 0.03446 903 0.08740 904 0.10095 905 0.04643 906

-0.03294 907

-0.00374 908 0.00422 909

-0.04593 910

-0.11844 911

-0.11031 912

-0.07194 913

-0.10867 914

-0.15375 915

-0.14891 916

-0.14898 917

-0.16889 918

-0.18441 919

-0.17914 920

-0.13725 921

-0.05723 922

-0.03740 923 0.03941 924 0.05570 925 0.04670 926 0.03461 927 0.03604 928 0.01007 929 0.04366 930 0.03943 931 0.01799 932 0.02780 933 0.02439 934 0.00613 935 0.00701 936 0.01557 937 0.03646 938 0.03442 939 0.00189 940 0.00114 941

-0.00268 -0.00465 942

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number. 145 of 196 Date: 11/06/02

-0.00633 -0.00751 -0.00806 -0.00791 -0.00711 -0.00573 -0.00404 -0.00229 943

-0.00076 0.00020 0.00048 -0.00008 -0.00150 -0.00375 -0.00667 -0.01018 944

-0.01377 -0.01707 -0.01967 -0.02110 -0.02134 -0.02023 -0.01793 -0.01470 945

-0.01056 -0.00573 -0.00030 0.00566 0.01179 0.01793 0.02371 0.02879 946 0.03325 0.03695 0.04029 0.04348 0.04681 0.05061 0.05470 0.05906 947 0.06323 0.06676 0.06933 0.07045 0.07016 0.06835 0.06524 0.06110 948 0.05607 0.05045 0.04444 0.03816 0.03223 0.02687 0.02285 0.020?4 949 0.02066 0.02292 0.02695 0.03237 0.03844 0.04432 0.04970 0.05408 950 0.05746 0.05979 0.06132 0.06231 0.06304 0.06380 0.06465 0.06570 951 0.06667 0.06735 0.06746 0.06660 0.06481 0.06196 0.05822 0.05380 952 0.04873 0.04316 0.03710 0.03053 0.02359 0.01634 0.00889 0.00139 953

-0.00611 -0.01352 -0.02069 -0.02750 -0.03371 -0.03919 -0.04359 -0.04677 954

-0.04830 -0.04801 -0.04587 -0.04166 -0.03599 -0.02937 -0.02300 -0.01781 955

-0.01421 -0.01297 -0.01349 -0.01556 -0.01833 -0.02086 -0.02291 -0.02388 956

-0.02412 -0.02376 -0.02335 -0.02350 -0.02433 -0.02628 -0.02888 -0.03198 957

-0.03508 -0.03746 -0.03925 -0.04044 -0.04158 -0.04306 -0.04491 -0.04752 958

-0.05040 -0.05332 -0.05591 -0.05770 -0.05873 -0.05890 -0.05856 -0.05796 959

-0.05720 -0.05657 -0.05603 -0.05578 -0.05586 -0.05633 -0.05698 -0.05749 960

-0.05820 -0.05915 -0.06039 -0.06219 -0.06405 -0.06585 -0.06710 -0.06725 961

-0.06652 -0.06476 -0.06237 -0.05980 -0.05680 -0.05365 -0.04972 -0.04470 962

-0.03889 -0.03223 -0.02525 -0.01830 -0.01198 -0.00700 -0.00337 -0.00137 963

-0.00052 -0.00047 -0.00067 -0.00049 0.00037 0.00236 0.00546 0.00965 964 0.01495 0.02104 0.02787 0.03522 0.04260 0.04976 0.05612 0.06121 965 0.06474 0.06624 0.06620 0.06481 0.06285 0.06115 0.05989 0.05952 966 0.05966 0.06004 0.06027 0.05990 0.05890 0.05697 0.05446 0.05166 967 0.04913 0.04734 0.04667 0.04751 0.04986 0.05380 0.05884 0.06452 968 0.07018 0.07514 0.07910 0.08156 0.08283 0.08302 0.08246 0.08155 969 0.08048 0.07964 0.07890 0.07818 0.07722 0.07577 0.07385 0.07126 970 0.06824 0.06488 0.06143 0.05813 0.05499 0.05213 0.04935 0.04649 971 0.04345 0.04001 0.03629 0.03227 0.02813 0.02410 0.02028 0.01681 972 0.01378 0.01122 0.00920 0.00771 0.00676 0.00633 0.00636 0.00681 973 0.00758 0.00857 0.00971 0.01088 0.01212 0.01338 0.01485 0.01659 974 0.01875 0.02149 0.02458 0.02796 0.03110 0.03360 0.03508 0.03501 975 0.03369 0.03108 0.02781 0.02438 0.02115 0.01871 0.01686 0.01565 976 0.01487 0.01412 0.01370 0.01347 0.01377 0.01491 0.01663 0.01903 977 0.02156 0.02379 0.02554 0.02636 0.02662 0.02643 0.02615 0.02619 978 0.02648 0.02720 0.02794 0.02838 0.02825 0.02710 0.02508 0.02214 979 0.01863 0.01483 0.01109 0.00785 0.00505 0.00286 0.00094 -0.00092 980

-0.00293 -0.00546 -0.00822 -0.01119 -0.01399 -0.01623 -0.01786 -0.01861 981

-0.01870 -0.01829 -0.01752 -0.01668 -0.01567 -0.01460 -0.01333 -0.01177 982

-0.00994 -0.00783 -0.00571 -0.00370 -0.00228 -0.00181 -0.00241 -0.00440 983

-0.00735 -0.01109 -0.01506 -0.01861 -0.02169 -0.02395 -0.02561 -0.02689 984

-0.02774 -0.02845 -0.02876 -0.02860 -0.02798 -0.02675 -0.02528 -0.02379 985

-0.02243 -0.02150 -0.02081 -0.02038 -0.01996 -0.01928 -0.01844 -0.01730 986

-0.01618 -0.01531 -0.01472 -0.01469 -0.01478 -0.01485 -0.01451 -0.01331 987

-0.01150 -0.00897 -0.00632 -0.00410 -0.00240 -0.00170 -0.00157 -0.00190 988

-0.00243 -0.00272 -0.00313 -0.00369 -0.00485 -0.00706 -0.01025 -0.01469 989

-0.01980 -0.02524 -0.03048 -0.03487 -0.03838 -0.04070 -0.04213 -0.04287 990

-0.04311 -0.04325 -0.04298 -0.04231 -0.04081 -0.03806 -0.03414 -0.02885 991

-0.02271 -0.01616 -0.00964 -0.00376 0.00125 0.00504 0.00758 0.00888 992 0.00908 0.00830 0.00689 0.00514 0.00328 0.00157 -0.00006 -0.00157 993

-0.00320 -0.00521 -0.00754 -0.01031 -0.01321 -0.01606 -0.01857 -0.02046 994

-0.02171 -0.02215 -0.02203 -0.02153 -0.02087 -0.02037 -0.02004 -0.02007 995

-0.02031 -0.02066 -0.02122 -0.02187 -0.02291 -0.02455 -0.02681 -0.02997 996

-0.03363 -0.03761 -0.04164 -0.04530 -0.04859 -0.05141 -0.05369 -0.05553 997

-0.05673 -0.05722 -0.05709 -0.05628 -0.05519 -0.05411 -0.05323 -0.05290 998

-0.05293 -0.05329 -0.05376 -0.05405 -0.05411 -0.05379 -0.05307 -0.05197 999

-0.05041 -0.04841 -0.04601 -0.04329 -0.04034 -0.03731 -0.03436 -0.03164 1000

-0.02933 -0.02757 -0.02639 -0.02591 -0.02587 -0.02614 -0.02656 -0.02688 1001

-0.02730 -0.02779 -0.02867 -0.03025 -0.03243 -0.03536 -0.03862 -0.04190 1002

-0.04491 -0.04725 -0.04893 -0.04986 -0.05018 -0.05014 -0.04980 -0.04936 1003

-0.04885 -0.04838 -0.04796 -0.04763 -0.04745 -0.04742 -0.04761 -0.04807 1004

-0.04874 -0.04961 -0.05039 -0.05092 -0.05085 -0.04992 -0.04803 -0.04503 1005

-0.04115 -0.03662 -0.03170 -0.02673 -0.02195 -0.01764 -0.01384 -0.01067 1006

-0.00793 -0.00550 -0.00321 -0.00083 0.00152 0.00384 0.00590 0.00743 1007 0.00847 0.00878 0.00874 0.00857 0.00843 0.00866 0.00914 0.00985 1008 0.01087 0.01210 0.01383 0.01620 0.01929 0.02325 0.02787 0.03302 1009 0.03848 0.04391 0.04929 0.05446 0.05940 0.06403 0.06835 0.07234 1010 0.07589 0.07895 0.08135 0.08293 0.08372 0.08360 0.08284 0.08160 1011 0.08003 0.07839 0.07660 0.07467 0.07263 0.07032 0.06802 0.06582 1012 0.06387 0.06237 0.06118 0.06024 0.05946 0.05857 0.05777 0.05701 1013 0.05643 0.05614 0.05605 0.05616 0.05623 0.05613 0.05561 0.05442 1014 0.05260 0.05000 0.04700 0.04383 0.04075 0.03813 0.03588 0.03404 1015

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 146 of 196 Date: 11/06/02 0.03245 0.03087 0.02422 0.02461 0.02954 0.03103 0.03908 0.03828 0.03566 0.03413 0.00886 0.00729

-0.00833 -0.01126

-0.02472 -0.02728

-0.02651 -0.02417

-0.00700 -0.00353 0.00639 0.00659 0.01609 0.01763 0.02868 0.03063 0.02596 0.02195 0.00861 0.00943 0.01910 0.01910 0.00836 0.00610

-0.00965 -0.01178

-0.02716 -0.02718

-0.02084 -0.02067

-0.01811 -0.01752

-0.02139 -0.02274

-0.03500 -0.03623

-0.03978 -0.04237

-0.06390 -0.06455

-0.06135 -0.06007

-0.06458 -0.06730

-0.07145 -0.07074

-0.05734 -0.05440

-0.03623 -0.03258

-0.01716 -0.01642

-0.01453 -0.01579

-0.01734 -0.01768

-0.01240 -0.01016 0.01446 0.01744 0.02349 0.02420 0.02250 0.02324 0.02469 0.02317 0.01068 0.00746 0.00126 0.00362 0.02020 0.02159 0.02659 0.02809 0.04208 0.04345 0.05187 0.05348 0.06473 0.06501 0.05520 0.05304 0.05072 0.05186 0.04291 0.04167 0.04082 0.04010 0.02822 0.02530 0.01844 0.01840 0.00336 0.00117

-0.01368 -0.01502

-0.01007 -0.00812 0.00906 0.01131 0.03631 0.03912 0.05154 0.05454 0.07174 0.07369 0.07632 0.07540 0.07247 0.07040 0.06566 0.06593 0.06373 0.06335 0.05271 0.05129 0.03789 0.03548 0.02720 0.02715 0.01433 0.01113 0.00153 0.00119

-0.00157 -0.00203 0.00566 0.00853 0.02501 0.02736 0.03520 0.03289 0.01888 0.01926 0.00897 0.00588 p

I I

I II I

I 0.02937 0.02778 0.02634 0.02518 0.02573 0.02632 0.03276 0.03465 0.03646 0.03733 0.03654 0.03600 0.03163 0.02790 0.02357 0.00616 0.00501 0.00356

-0.01377 -0.01556 -0.01705

-0.02959 -0.03124 -0.03210

-0.02184 -0.01982 -0.01780

-0.00024 0.00246 0.00452 0.00707 0.00797 0.00924 0.01907 0.02043 0.02181 0.03236 0.03368 0.03426 0.01792 0.01442 0.01157 0.01070 0.01227 0.01399 0.01855 0.01746 0.01598 0.00377 0.00136 -0.00103

-0.01409 -0.01675 -0.01947

-0.02654 -0.02545 -0.02413

-0.02061 -0.02049 -0.02028

-0.01711 -0.01703 -0.01727

-0.02420 -0.02575 -0.02743

-0.03698 -0.03716 -0.03710

-0.04564 -0.04945 -0.05337

-0.06464 -0.06453 -0.06417

-0.05891 -0.05808 -0.05782

-0.06980 -0.07166 -0.07286

-0.06990 -0.06897 -0.06768

-0.05163 -0.,04931 -0.04711

-0.02892 -0.02555 -0.02263

-0.01566 -0.01464 -0.01372

-0.01697 -0.01760 -0.01788.

-0.01803 -0.01815 -0.01796

-0.00750 -0.00443 -0.00097 0.01974 0.02112 0.02193 0.02476 0.02484 0.02460 0.02433 0.02560 0.02669 0.02158 0.02021 0.01883 0.00423 0.00138 -0.00078 0.00631 0.00901 0.01166 0.02266 0.02338 0.02391 0.02994 0.03210 0.03439 0.04466 0.04579 0.04689 0.05527 0.05721 0.05917 0.06477 0.06403 0.06285 0.05113 0.04957 0.04857 0.05255 0.05235 0.05138 0.04100 0.04091 0.04115 0.03914 0.03802 0.03665 0.02251 0.02011 0.01834 0.01776 0.01611 0.01385

-0.00090 -0.00303 -0.00518

-0.01581 -0.01590 -0.01544

-0.00593 -0.00339 -0.00073 0.01384 0.01694 0.02047 0.04130 0.04281 0.04404 0.05772 0.06076 0.06361 0.07549 0.07707 0.07819 0.07474 0.07464 0.07475 0.06822 0.06636 0.06497 0.06597 0.06557 0.06501 0.06269 0.06146 0.05990 0.04995 0.04851 0.04692 0.03325 0.03134 0.02981 0.02695 0.02641 0.02531 0.00828 0.00617 0.00459 0.00092 0.00070 0.00045

-0.00226 -0.00212 -0.00154 0.01147 0.01426 0.01685 0.02981 0.03235 0.03458 0.03001 0.02686 0.02387 0.01965 0.01955 0.01885 0.00283 -0.00003 -0.00285 0.02518 0.02689 0.03800 0.03599 0.01903 0.00125

-0.01855

-0.03186

-0.01567 0.00570

0. 01083 0.02330 0.03380 0.00963 0.01576 0.01431

-0.00335

-0.02217

-0.02292

-0.01993

-0.01795

-0.02936

-0. 03701

-0.05706

-0.06378

-0.05845

-0.07318

-0.06574

-0.04487

-0.02047

-0.01311

-0.01771

-0.01719 0.00290 0.02230 0.02382 0.02709 0.01740

-0.00180 0.01413 0.02432 0.03661 0.04799 0.06104 0.06130 0.04826 0.04948 0.04135 0.03507 0.01757 0.01119

-0.00747

-0.01453 0.00193 0.02453 0.04531 0.06594 0.07853 0.07491 0.06449 0.06452 0.05805 0.04498 0.02863 0.02341 0.00343 0.00009

-0.00051 0.01902 0.03614

0. 02145 0.01725

-0.00577 0.02431 0.0275' 0.03901

0. 0360!

0.01471

-0.0015!

-0.0201!

-0.0307!

-0.0132!

0.0062-0.0126C 0.0249!

0.03221 0.00855 0.01732 0.01245

-0.00558

-0.02452

-0.02189

-0.01943

-0. 01892

-0.03132

-0.03723

-0.06021

-0.06321

-0.05983

-0.07292

-0.06334

-0.04242

-0.01889

-0.01293

-0.01739

-0.01598 0.00690 0.02251 0.02303 0.02693 0.01568

-0.00179 0.01639 0.02482 0.03871 0.04916 0.06268 0.05945 0.04858 0.04719 0.04148 0.03316 0.01744 0.00836

-0.00972

-0.01323 0.00451 0.02872 0.04685 0.06803 0.07830 0.07479 0.06457 0.06409 0.05612 0.04280 0.02785 0.02089 0.00265

-0.00037 0.00105 0.02103 0.03688 0.01974 0.01498

-0.00876 0.02412 0.02842 60.03934 90.03615 80.01142 9 -0.00494

-0.02234 5-0.02884 5-0.01026 7 0.00640 0.01437 50.02676 B0.02951 0.00823 0.01845 0.01047

-0.00761

-0.02621

-0.02123

-0.01878

-0.02008

-0.03330

-0.03813

-0.06245

-0.06237

-0.06200

-0.07230

-0.06043

-0.03950

-0.01789

-0.01355

-0.01731

-0.01440 0.01085 0.02297 0.02255 0.02602 0.01338

-0.00067 0.01844 0.02553 0.04051 0.05043 0.06393 0.05736 0.04954 0.04491 0.04128 0.03082 0.01792 0.00578

-0.01185

-0.01178 0.00680 0.03272 0.04897 0.06993 0.07741 0.07389 0.06505 0.06392 0.05435 0.04038 0.02741 0.01771 0.00200

-0.00098 0.00315 0.02298 0.03653 0.01899 0.01212

-0.01195 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088

Calc Number: GEO.HBEIP.02.06 Rev Number: 0 Sheet Number: 147 of 196 Date: 11/06/02

-0.01511 -0.01817 -0.02087

-0.02463 -0.02417 -0.02393

-0.02836 -0.02852 -0.02809

-0.01691 -0.01552 -0.01464

-0.01267 -0.01107 -0.00930

-0.00277 -0.00130 0.00045 0.00324 0.00063 -0.00230

-0.01294 -0.01381 -0.01443

-0.01250 -0.01228 -0.01225

-0.00915 -0.00724 -0.00540

-0.00849 -0.01070 -0.01273

-0.01743 -0.01805 -0.01867

-0.01820 -0.01749 -0.01683

-0.01614 -0.01631 -0.01662

-0.02413 -0.02579 -0.02713

-0.03024 -0.03145 -0.03256

-0.02662 -0.02435 -0.02234

-0.02166 -0.02284 -0.02427

-0.03968 -0.04274 -0.04534

-0.04650 -0.04546 -0.04423

-0.03349 -0.03202 -0.03100

-0.03448 -0.03532 -0.03597

-0.03991 -0.04144 -0.04310

-0.04618 -0.04465 -0.04280

-0.03327 -0.03232 -0.03164

-0.03489 -0.03619 -0.03738

-0.04170 -0.04279 -0.04384

-0.04509 -0.04536 -0.04588

-0.05232 -0.05381 -0.05539

-0.06007 -0.05909 -0.05788

-0.05083 -0.04878 -0.04651

-0.03860 -0.03886 -0.03927

-0.04064 -0.04134 -0.04218

-0.04161 -0.03991 -0.03819

-0.03536 -0.03556 -0.03592

-0.04254 -0.04329 -0.04344

-0.03826 -0.03876 -0.03945

-0.03080 -0.02682 -0.02281

-0.01163 -0.01189 -0.01232

-0.01009 -0.00923 -0.00869

-0.01367 -0.01383 -0.01339

-0.00693 -0.00623 -0.00522 0.01154 0.01472 0.01769 0.02904 0.02946 0.02935 0.02187 0.02071 0.01967 0.01272 0.01104 0.00919

-0.00139 -0.00196 -0.00209

-0.00142 -0.00213 -0.00270 0.00774 0.01126 0.01461 0.02157 0.02094 0.02009 0.01811 0.01947 0.02128 0.02842 0.02756 0.02647 0.02446 0.02447 0.02451 0.02574 0.02525 0.02414 0.00620 0.00340 0.00120

-0.00004 0.00031 0.00044

-0.00297 -0.00352 -0.00393

-0.00421 -0.00405 -0.00380

-0.00043 0.00007 0.00046 0.00142 0.00169 0.00207 0.00420 0.00442 0.00493 0.01203 0.01191 0.01147 0.01513 0.01683 0.01841 0.02468 0.02604 0.02699 0.01691 0.01500 0.01364 0.01445 0.01570 0.01748 0.03195 0.03221 0.03182 0.02612 0.02457 0.02268 0.00674 0.00436 0.00224

-0.00430 -0.00400 -0.00334 0.00023 -0.00036 -0.00127

-0.00866 -0.00969 -0.01083

-0.02350 -0.02562 -0.02738

-0.02300

-0.02416

-0.02701

-0.01439

-0.00768 0.00254

-0.00500

-0.01473

-0.01244

-0. 00402

-0.01422

-0.01925

-0.01636

-0.01708

-0.02788

-0.03325

-0.02089

-0.02595

-0.04715

-0.04280

-0.03063

-0.03641

-0.04477

-0.04089

-0. 03128

-0.03828

-0.04468

-0.04672

-0.05712

-0.05675

-0.04418

-0.03962

-0.04315

-0.03682

-0.03645

-0.04281

-0.04001

-0.01921

-0.01269

-0.00871

-0.01227

-0.00354 0.02038 0.02866 0.01871 0.00720

-0.00181

-0.00285 0.01742 0.01917 0.02345 0.02552 0.02456 0.02219

-0.00030 0.00025

-0.00418

-0.00346 0.00073 0.00262 0.00591 0.01092 0.01952 0.02709 0.01300 0.01998 0.03106 0.02037 0.00040

-0.00236

-0.00245

-0.01227

-0.02867

-0.02450

-0.02476

-0.02537

-0.01441

-0.00624 0.00441

-0.00743

-0.01473

-0.01256

-0.00328

-0.01531

-0.01965

-0.01605

-0.01782

-0.02831

-0.03336

-0.02000

-0.02797

-0.04823

-0.04117

-0.03079

-0.03677

-0.04620

-0. 03900

-0.03128

-0.03901

-0.04527

-0.04775

-0.05868

-0.05563

-0.04202

-0.03991

-0.04391

-0.03578

-0.03724

-0.04173

-0.04006

-0.01617

-0.01283

-0.00922

-0. 01086

-0.00129 0.02279 0.02757 0.01776 0.00516

-0.00136

-0.00235 0.01961

0. 01831 0.02557 0.02475 0.02470 0.01959

-0.00113

-0.00019

-0.00431

-0.00300 0.00092 0.00319 0.00718 0.01060 0.02045 0.02638 0.01284 0.02283 0.03007 0.01777

-0.00116

-0.00131

-0.00375

-0.01402

-0.02953

-0.02525

-0.02568

-0.02331

-0.01450

-0.00528 0.00561

-0.00930

-0.01432

-0.01242

-0.00352

-0.01601

-0.01970

-0.01593

-0.01898

-0. 02851

-0. 03254

-0.01973

-0. 03043

-0.04849

-0.03931

-0.03143

-0.03720

-0.04716

-0.03730

-0.03172

-0.03958

-0.04541

-0.04879

-0.05989

-0.05469

-0.04036

-0.04001

-0.04421

-0.03526

-0.03843

-0.04039

-0.03917

-0.01396

-0.01258

-0.01029

-0.00952 0.00157 0.02492 0.02618 0.01671 0.00311

-0.00094

-0. 00091 0.02102 0.01760 0.02728 0.02439 0.02501 0.01641

-0.00134

-0.00084

-0.00436

-0.00238 0.00104 0.00365 0.00880 0.01094 0.02128 0.02455 0.01291 0.02589 0.02917 0.01497

-0.00249

-0.00042

-0.00509

-0.01618

-0.02998

-0.02541 -0.02512 3-0.02672 -0.02769 L -0.02106 -0.01885 I -0.01439 -0.01374 3 -0.00447 -0.00372 0.00597 0.00505

-0.01078 -0.01200

-0.01373 -0.01307

-0.01186 -0.01071

-0.00455 -0.00633

-0.01648 -0.01696

-0.01947 -0.01892

-0.01593 -0.01600

-0.02044 -0.02228

-0.02874 -0.02938

-0.03104 -0.02897

-0.01998 -0.02066

-0.03323 -0.03643

-0.04816 -0.04748

-0.03735 -0.03533

-0.03237 -0.03343

-0.03779 -0.03871

-0.04754 -0.04716

-0.03578 -0.03442

-0.03250 -0.03363

-0.04013 -0.04086

-0.04534 -0.04518

-0.04992 -0.05106

-0.06061 -0.06060

-0.05366 -0.05240

-0.03918 -0.03867

-0.04010 -0.04028

-0.04398 -0.04303

-0.03508 -0.03513

-0.03979 -0.04129

-0.03917 -0.03848

-0.03733 -0.03442

-0.01251 -0.01178

-0.01200 -0.01109

-0.01155 -0.01279

-0.00831 -0.00757 0.00482 0.00817 0.02669 0.02810 0.02467 0.02322 0.01555 0.01423 0.00126 -0.00028

-0.00070 -0.00093 0.00132 0.00431 0.02176 0.02190 0.01726 0.01740 0.02845 0.02875 0.02428 0.02432 0.02536 0.02569 0.01295 0.00946

-0.00110 -0.00060

-0.00158 -0.00231

-0.00435 -0.00431

-0.00170 -0.00104 0.00114 0.00124 0.00401 0.00410 0.01034 0.01142 0.01180 0.01333 0.02218 0.02340 0.02215 0.01948 0.01327 0.01368 0.02869 0.03069 0.02823 0.02726 0.01211 0.00935

-0.00348 -0.00410 0.00022 0.00043

-0.00639 -0.00756

-0.01857 -0.02108

-0.03011 -0.03005 1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157 1158 1159 1160 1161

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 148 of 196 Date: 11/06/02

-0.02988 -0.02967 -0.02956 -0.02972 -0.03003 -0.03048 -0.03094 -0.03127 1162

-0.03146 -0.03140 -0.03122 -0.03102 -0.03078 -0.03062 -0.03043 -0.03012 1163

-0.02968 -0.02904 -0.02820 -0.02717 -0.02595 -0.02456 -0.02308 -0.02161 1164

-0.02016 -0.01884 -0.01750 -0.01614 -0.01461 -0.01275 -0.01075 -0.00861 1165

-0.00675 -0.00550 -0.00496 -0.00542 -0.00659 -0.00833 -0.01030 -0.01216 1166

-0.01370 -0.01468 -0.01512 -0.01498 -0.01452 -0.01401 -0.01352 -0.01334 1167

-0.01327 -0.01329 -0.01323 -0.01288 -0.01233 -0.01154 -0.01070 -0.00994 1168

-0.00940 -0.00925 -0.00945 -0.01006 -0.01082 -0.01158 -0.01210 -0.01210 1169

-0.01171 -0.01088 -0.00990 -0.00904 -0.00836 -0.00817 -0.00823 -0.00844 1170

-0.00868 -0.00878 -0.00869 -0.00839 -0.00784 -0.00704 -0.00607 -0.00495 1171

-0.00382 -0.00281 -0.00187 -0.00112 -0.00033 0.00063 0.00177 0.00325 1172 0.00488 0.00650 0.00806 0.00940 0.01051 0.01136 0.01193 0.01221 1173 0.01242 0.01262 0.01317 0.01433 0.01616 0.01884 0.02205 0.02556 1174 0.02915 0.03235 0.03534 0.03807 0.04057 0.04305 0.04520 0.04697 1175 0.04811 0.04834 0.04778 0.04639 0.04451 0.04239 0.04033 0.03862 1176 0.03735 0.03667 0.03639 0.03646 0.03658 0.03641 0.03602 0.03520 1177 0.03426 0.03341 0.03275 0.03252 0.03256 0.03280 0.03311 0.03323 1178 0.03328 0.03323 0.03316 0.03316 0.03319 0.03329 0.03340 0.03346 1179 0.03347 0.03343 0.03327 0.03296 0.03253 0.03194 0.03135 0.03084 1180 0.03050 0.03046 0.03062 0.03091 0.03123 0.03138 0.03134 0.03100 1181 0.03036 0.02937 0.02815 0.02671 0.02527 0.02399 0.02287 0.02205 1182 0.02126 0.02034 0.01915 0.01745 0.01540 0.01304 0.01057 0.00821 1183 0.00604 0.00418 0.00266 0.00147 0.00065 0.00023 0.00011 0.00023 1184 0.00057 0.00100 0.00178 0.00293 0.00469 0.00731 0.01052 0.01426 1185 0.01805 0.02147 0.02429 0.02610 0.02712 0.02733 0.02713 0.02690 1186 0.02677 0.02704 0.02759 0.02842 0.02935 0.03011 0.03083 0.03137 1187 0.03206 0.03308 0.03451 0.03658 0.03894 0.04139 0.04367 0.04539 1188 0.04655 0.04698 0.04688 0.04640 0.04566 0.04487 0.04395 0.04295 1189 0.04170 0.04003 0.03801 0.03553 0.03293 0.03033 0.02807 0.02645 1190 0.02541 0.02506 0.02504 0.02503 0.02484 0.02412 0.02292 0.02118 1191 0.01907 0.01677 0.01441 0.01212 0.00999 0.00812 0.00642 0.00484 1192 0.00330 0.00167 0.00009 -0.00149 -0.00279 -0.00366 -0.00402 -0.00372 1193

-0.00294 -0.00181 -0.00050 0.00072 0.00192 0.00299 0.00412 0.00543 1194 0.00704 0.00913 0.01162 0.01449 0.01763 0.02088 0.02413 0.02723 1195 0.03016 0.03283 0.03524 0.03741 0.03932 0.04094 0.04230 0.04340 1196 0.04428 0.04492 0.04536 0.04564 0.04572 0.04560 0.04530 0.04479 1197 0.04419 0.04355 0.04296 0.04253 0.04220 0.04197 0.04177 0.04145 1198 0.04116 0.04081 0.04062 0.04072 0.04100 0.04151 0.04187 0.04184 1199 0.04121 0.03966 0.03749 0.03479 0.03198 0.02949 0.02746 0.02621 1200 0.02549 0.02514 0.02497 0.02468 0.02423 0.02349 0.02252 0.02135 1201 0.02001 0.01863 0.01710 0.01541 0.01360 0.01161 0.00968 0.00787 1202 0.00641 0.00547 0.00494 0.00484 0.00485 0.00468 0.00421 0.00315 1203 0.00167 -0.00020 -0.00221 -0.00410 -0.00586 -0.00732 -0.00863 -0.00992 1204

-0.01116 -0.01243 -0.01362 -0.01470 -0.01555 -0.01605 -0.01629 -0.01625 1205

-0.01610 -0.01600 -0.01600 -0.01628 -0.01669 -0.01718 -0.01761 -0.01782 1206

-0.01786 -0.01770 -0.01746 -0.01727 -0.01709 -0.01701 -0.01695 -0.01688 1207

-0.01682 -0.01675 -0.01670 -0.01675 -0.01678 -0.01677 -0.01665 -0.01634 1208

-0.01586 -0.01521 -0.01444 -0.01363 -0.01284 -0.01213 -0.01161 -0.01136 1209

-0.01147 -0.01205 -0.01306 -0.01453 -0.01628 -0.01818 -0.02010 -0.02188 1210

-0.02347 -0.02478 -0.02578 -0.02652 -0.02687 -0.02680 -0.02632 -0.02542 1211

-0.02422 -0.02281 -0.02137 -0.02007 -0.01901 -0.01840 -0.01811 -0.01810 1212

-0.01826 -0.01844 -0.01857 -0.01857 -0.01842 -0.01816 -0.01776 -0.01731 1213

-0.01680 -0.01626 -0.01577 -0.01544 -0.01534 -0.01556 -0.01614 -0.01711 1214

-0.01844 -0.02017 -0.02200 -0.02385 -0.02542 -0.02646 -0.02700 -0.02695 1215

-0.02661 -0.02620 -0.02593 -0.02613 -0.02663 -0.02742 -0.02829 -0.02900 1216

-0.02955 -0.02984 -0.02996 -0.02998 -0.02997 -0.03006 -0.03027 -0.03064 1217

-0.03128 -0.03223 -0.03355 -0.03533 -0.03738 -0.03965 -0.04185 -0.04377 1218

-0.04526 -0.04613 -0.04650 -0.04637 -0.04601 -0.04572 -0.04555 -0.04573 1219

-0.04606 -0.04654 -0.04688 -0.04681 -0.04633 -0.04533 -0.04400 -0.04247 1220

-0.04093 -0.03963 -0.03862 -0.03812 -0.03786 -0.03774 -0.03753 -0.03692 1221

-0.03601 -0.03472 -0.03326 -0.03188 -0.03056 -0.02945 -0.02837 -0.02722 1222

-0.02595 -0.02442 -0.02271 -0.02086 -0.01897 -0.01711 -0.01540 -0.01400 1223

-0.01283 -0.01194 -0.01112 -0.01029 -0.00940 -0.00827 -0.00729 -0.00664 1224

-0.00648 -0.00719 -0.00831 -0.00975 -0.01097 -0.01141 -0.01125 -0.01028 1225

-0.00911 -0.00826 -0.00789 -0.00851 -0.00979 -0.01165 -0.01370 -0.01549 1226

-0.01701 -0.01799 -0.01874 -0.01943 -0.02031 -0.02177 -0.02366 -0.02613 1227

-0.02870 -0.03103 -0.03298 -0.03417 -0.03501 -0.03568 -0.03654 -0.03811 X228

-0.04022 -0.04304 -0.04616 -0.04923 -0.05200 -0.05410 -0.05549 -0.05602 1229

-0.05585 -0.05516 -0.05409 -0.05286 -0.05156 -0.05041 -0.04928 -0.04815 1230

-0.04698 -0.04570 -0.04441 -0.04315 -0.04202 -0.04118 -0.04053 -0.04010 1231

-0.03978 -0.03942 -0.03900 -0.03847 -0.03777 -0.03690 -0.03580 -0.03443 1232

-0.03289 -0.03122 -0.02952 -0.02795 -0.02643 -0.02499 -0.02354 -0.02200 1233

-0.02046 -0.01888 -0.01750 -0.01649 -0.01585 -0.01573 -0.01593 -0.01635 1234

Caic Number: GEO.HBIP.02.06

-0.01684

-0.01599

-0.01628

-0.00660 0.00477 0.02014 0.02614 0.02372 0.01469 0.00404 0.00586 0.01176 0.00260 0.00037 0.00751 0.00999 0.01438 0.02270 0.01792

0. 02469 0.02761 0.02988 0.02393 0.03002 0.04078 0.05161 0.04827 0.04525 0.04410 0.03073 0.02369 0.02172 0.01667 0.02074 0.03505 0.02903 0.01149

-0.00429

-0.01285

-0.00787

-0.00808 0.00110

-0.00358

-0.00804

-0.01388

-0.02224

-0.03472

-0.02424

-0.02182

-0.02120

-0.02779

-0.02142

-0.01810

-0.02363

-0.01800

-0.01429

-0.02322

-0.03016

-0.03221

-0.02815

-0.02541

-0.01054

-0.00469

-0.00699 0.00542 0.01419 0.00854

-0.01085

-0.01371

-0.01814

-0.02451

-0.01835

-0.01373

-0.01720

-0.01640

-0.01526

-0.00459 0.00653 0.02049 0.02652 0.02267 0.01380 0.00407 0.00576 0.01212 0.00141 0.00040 0.00790 0.01061 0.01616 0.02213 0.01772 0.02592 0.02685 0.03031 0.02415 0.03181 0.04103 0.05265 0.04738 0.04581 0.04224 0.02983 0.02273 0.02082 0.01743 0.02182 0.03556 0.02777 0.00906

-0.00620

-0.01252

-0.00794

-0.00722 0.00125

-0.00357

-0.00917

-0.01494

-0.02425

-0.03484

-0.02217

-0.02166

-0.02233

-0.02775

-0.02026

-0.01794

-0.02351

-0. 01804

-0.01558

-0.02279

-0.03040

-0.03322

-0.02831

-0.02280

-0. 00884

-0. 00536

-0.00692 0.00762 0.01422 0.00682

-0.01192

-0.01471

-0.01892

-0.02494

-0.01710

-0.01419

-0.01739

-0.01697

-0.01422

-0.00264 0.00868 0.02076 0.02662 0.02149 0.01272 0.00453 0.00590 0.01192 0.00062 0.00064 0.00797 0.01109 0.01809 0.02145 0.01786 0.02699 0.02627 0.03022 0.02474 0.03379 0.04150

0. 05309 0.04658 0.04641 0.04021 0.02905 0.02202 0.01966 0.01825 0.02334 0.03549 0.02632 0.00687

-0.00801

-0.01195

-0.00824

-0.00617 0.00093

-0.00349

-0.01007

-0.01595

-0.02638

-0.03451

-0.02059

-0.02121

-0.02357

-0.02745

-0.01929

-0.01798

-0. 02284

-0.01796

-0.01744

-0.02263

-0.03020

-0.03375

-0.02881

-0.02012

-0.00711

-0.00599

-0.00654 0.00947 0.01400 0.00471

-0.01242

-0.01567

-0.01981

-0.02502

-0.01596

-0.01470

-0.01733

-0.01770

-0.01338

-0.00097 0.01128 0.02133 0.02650 0.02016 0.01127 0.00522 0.00643 0.01107 0.00024 0.00128 0.00782 0.01123 0.01992 0.02083 0.01848 0.02793 0.02606 0.02939 0.02545 0.03584 0.04242 0.05282 0.04578 0.04693 0.03817 0.02833 0.02172 0.01831 0.01884 0.02533 0.03487 0.02451 0.00491

-0.00965

-0.01129

-0.00875

-0.00499 0.00013

-0.00348

-0.01054

-0.01664

-0.02846

-0.03378

-0.01986

-0.02060

-0.02472

-0.02692

-0.01869

-0.01847

-0.02167

-0.01746

-0.01968

-0.02321

-0.02964

-0.03335

-0.02948

-0.01783

-0.00555

-0.00641

-0.00571 0.01078 0.01344 0.00208

-0.01242

-0.01629

-0.02063

-0.02456

-0.01489

-0.01519

-0.01708

-0.01827

-0.01248 0.00046 0.01393 0.02211 0.02618 0.01884 0.00962 0.00592 0.00728 0.00972 0.00014 0.00224 0.00768 0.01133 0.02149 0.02022 0.01944 0.02858 0.02627 0.02817 0.02628 0.03771 0.04379 0.05209 0.04514 0.04722 0.03623 0.02759 0.02169 0.01708 0.01929 0.02760 0.03389 0.02238 0.00310

-0.01102

-0.01053

-0.00922

-0.00370

-0.00089

-0.00368

-0.01087

-0.01731

-0.03039

-0.03258

-0.01973

-0.02001

-0.02576

-0.02614

-0.01833

-0.01927

-0.02034

-0.01670

-0.02179

-0.02429

-0.02915

-0.03240

-0.02996

-0.01584

-0.00432

-0.00668

-0.00436 0.01177 0.01270

-0.00080

-0.01223

-0.01673

-0.02146

-0.02371

-0.01403

-0.01551

-0.01665 -0.01624

-0.01838 -0.01810

-0.01142 -0.01013 0.00153 0.00250 0.01628 0.01822 0.02321 0.02439 0.02576 0.02521 0.01758 0.01644 0.00774 0.00601 0.00624 0.00632 0.00844 0.00969 0.00797 0.00605 0.00022 0.00036 0.00364 0.00513 0.00792 0.00839 0.01153 0.01201 0.02252 0.02308 0.01957 0.01897 0.02067 0.02206 0.02888 0.02882 0.02696 0.02792 0.02667 0.02527 0.02695 0.02774 0.03907 0.04003 0.04568 0.04777 0.05115 0.05009 0.04474 0.04461 0.04713 0.04661 0.03454 0.03308 0.02676 0.02585 0.02193 0.02214 0.01630 0.01595 0.01954 0.01977 0.02993 0.03210 0.03273 0.03148 0.01981 0.01704 0.00129 -0.00051

-0.01205 -0.01271

-0.00968 -0.00890

-0.00940 -0.00931

-0.00224 -0.00086

-0.00189 -0.00274

-0.00433 -0.00529

-0.01132 -0.01187

-0.01809 -0.01907

-0.03199 -0.03325

-0.03094 -0.02894

-0.02022 -0.02092

-0.01975 -0.01981

-0.02660 -0.02721

-0.02514 -0.02398

-0.01827 -0.01829

-0.02054 -0.02185

-0.01924 -0.01840

-0.01556 -0.01456

-0.02313 -0.02384

-0.02594 -0.02768

-0.02925 -0.02977

-0.03103 -0.02962

-0.02990 -0.02918

-0.01440 -0.01317

-0.00373 -0.00363

-0.00682 -0.00688

-0.00233 0.00009 0.01262 0.01328 0.01188 0.01091

-0.00384 -0.00669

-0.01215 -0.01227

-0.01697 -0.01716

-0.02228 -0.02307

-0.02253 -0.02114

-0.01348 -0.01322

-0.01565 -0.01541 Rev Number: 0 Sheet Number. 149 of 196 Date: 11/06/02

-0.01600 1235

-0.01732 1236

-0.00847 1237 0.00350 1238 0.01941 1239 0.02536 1240 0.02454 1241 0.01555 1242 0.00477 1243 0.00612 1244 0.01087 1245 0.00421 1246 0.00035 1247 0.00646 1248 0.00916 1249 0.01300 1250 0.02307 1251 0.01836 1252 0.02338 1253 0.02831 1254 0.02899 1255 0.02437 1256 0.02874 1257 0.04051 1258 0.04984 1259 0.04916 1260 0.04481 1261 0.04556 1262 0.03180 1263 0.02475 1264 0.02209 1265 0.01613 1266 0.02012 1267 0.03384 1268 0.03027 1269 0.01422 1270

-0.00239 1271

-0.01295 1272

-0.00826 1273

-0.00883 1274 0.00031 1275

-0.00329 1276

-0.00664 1277

-0.01282 1278

-0.02051 1279

-0.03419 1280

-0.02658 1281

-0.02149 1282

-0.02034 1283

-0.02762 1284

-0.02270 1285

-0.01818 1286

-0.02295 1287

-0.01808 1288

-0.01410 1289

-0.02371 1290

-0.02914 1291

-0.03094 1292

-0.02867 1293

-0.02759 1294

-0.01189 1295

-0.00403 1296

-0.00698 1297 0.00277 1298 0.01384 1299 0.00986 1300

-0.00905 1301

-0.01287 1302

-0.01759 1303

-0.02387 1304

-0.01974 1305

-0.01336 1306

-0.01468 1307

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 150 of 196 Date: 11/06/02

-0.01361 -0.01215 -0.01076 -0.00977 -0.00931 -0.00972 -0.01068 -0.01201 1308

-0.01350 -0.01480 -0.01594 -0.01686 -0.01758 -0.01818 -0.01864 -0.01900 1309

-0.01929 -0.01952 -0.01968 -0.01987 -0.01991 -0.01976 -0.01937 -0.01864 1310

-0.01775 -0.01683 -0.01592 -0.01523 -0.01452 -0.01373 -0.01280 -0.01155 1311

-0.01017 -0.00874 -0.00736 -0.00623 -0.00528 -0.00453 -0.00387 -0.00321 1312

-0.00243 -0.00144 -0.00023 0.00126 0.00291 0.00462 0.00636 0.00794 1313 0.00953 0.01112 0.01281 0.01474 0.01665 0.01848 0.01996 0.02079 1314 0.02103 0.02053 0.01963 0.01859 0.01757 0.01684 0.01633 0.01606 1315 0.01585 0.01547 0.01496 0.01416 0.01329 0.01246 0.01180 0.01148 1316 0.01150 0.01188 0.01254 0.01334 0.01426 0.01513 0.01602 0.01692 1317 0.01778 0.01862 0.01932 0.01981 0.02012 0.02016 0.02010 0.02001 1318 0.01999 0.02016 0.02048 0.02089 0.02139 0.02190 0.02242 0.02288 1319 0.02335 0.02389 0.02443 0.02496 0.02538 0.02560 0.02562 0.02534 1320 0.02487 0.02429 0.02364 0.02299 0.02234 0.02172 0.02108 0.02038 1321 0.01962 0.01874 0.01785 0.01697 0.01623 0.01571 0.01543 0.01544 1322 0.01556 0.01570 0.01566 0.01518 0.01429 0.01286 0.01109 0.00910 1323 0.00708 0.00520 0.00359 0.00238 0.00152 0.00098 0.00060 0.00024 1324

-0.00024 -0.00109 -0.00215 -0.00348 -0.00486 -0.00607 -0.00717 -0.00805 1325

-0.00887 -0.00971 -0.01064 -0.01185 -0.01316 -0.01453 -0.01589 -0.01708 1326

-0.01825 -0.01941 -0.02067 -0.02215 -0.02374 -0.02548 -0.02708 -0.02836 1327

-0.02918 -0.02938 -0.02904 -0.02818 -0.02707 -0.02598 -0.02507 -0.02461 1328

-0.02456 -0.02498 -0.02582 -0.02699 -0.02844 -0.03007 -0.03177 -0.03346 1329

-0.03498 -0.03624 -0.03713 -0.03759 -0.03763 -0.03726 -0.03660 -0.03575 1330

-0.03483 -0.03398 -0.03326 -0.03278 -0.03251 -0.03245 -0.03252 -0.03264 1331

-0.03272 -0.03265 -0.03240 -0.03190 -0.03119 -0.03035 -0.02935 -0.02825 1332

-0.02701 -0.02562 -0.02413 -0.02257 -0.02105 -0.01971 -0.01853 -0.01761 1333

-0.01681 -0.01605 -0.01533 -0.01458 -0.01386 -0.01327 -0.01271 -0.01216 1334

-0.01159 -0.01097 -0.01030 -0.00959 -0.00886 -0.00818 -0.00753 -0.00692 1335

-0.00641 -0.00606 -0.00584 -0.00584 -0.00581 -0.00567 -0.00533 -0.00459 1336

-0.00377 -0.00298 -0.00245 -0.00254 -0.00292 -0.00359 -0.00417 -0.00427 1337

-0.00396 -0.00312 -0.00194 -0.00065 0.00073 0.00203 0.00333 0.00464 1338 0.00602 0.00751 0.00912 0.01082 0.01253 0.01421 0.01564 0.01662 1339 0.01717 0.01711 0.01675 0.01622 0.01571 0.01550 0.01546 0.01559 1340 0.01581 0.01589 0.01590 0.01580 0.01558 0.01529 0.01488 0.01430 1341 0.01366 0.01298 0.01248 0.01228 0.01244 0.01309 0.01400 0.01499 1342 0.01593 0.01658 0.01696 0.01700 0.01675 0.01626 0.01567 0.01505 1343 0.01455 0.01431 0.01423 0.01434 0.01447 0.01440 0.01420 0.01372 1344 0.01316 0.01271 0.01229 0.01197 0.01163 0.01113 0.01059 0.00996 1345 0.00937 0.00890 0.00853 0.00831 0.00818 0.00797 0.00784 0.00778 1346 0.00789 0.00828 0.00888 0.00966 0.01054 0.01135 0.01212 0.01279 1347 0.01340 0.01389 0.01436 0.01486 0.01539 0.01597 0.01650 0.01694 1348 0.01715 0.01696 0.01653 0.01579 0.01502 0.01446 0.01399 0.01370 1349 0.01336 0.01274 0.01187 0.01061 0.00926 0.00783 0.00658 0.00625 1350 0.00601 0.00508 0.00404 0.00299 0.00199 0.00121 0.00075 0.00072 1351 0.00112 0.00198 0.00319 0.00464 0.00622 0.00776 0.00925 0.01052 1352 0.01176 0.01304 0.01441 0.01607 0.01773 0.01926 0.02053 0.02127 1353 0.02175 0.02200 0.02230 0.02301 0.02397 0.02522 0.02652 0.02757 1354 0.02835 0.02859 0.02854 0.02829 0.02796 0.02773 0.02763 0.02772 1355 0.02794 0.02823 0.02853 0.02871 0.02881 0.02877 0.02865 0.02851 1356 0.02831 0.02812 0.02778 0.02718 0.02637 0.02520 0.02394 0.02275 1357 0.02166 0.02080 0.02005 0.01936 0.01862 0.01765 0.01655 0.01527 1358 0.01398 0.01279 0.01177 0.01105 0.01054 0.01019 0.00992 0.00958 1359 0.00922 0.00876 0.00838 0.00815 0.00816 0.00847 0.00906 0.00990 1360 0.01087 0.01186 0.01277 0.01346 0.01397 0.01422 0.01441 0.01467 1361 0.01502 0.01561 0.01622 0.01668 0.01693 0.01669 0.01622 0.01553 1362 0.01485 0.01447 0.01422 0.01410 0.01395 0.01358 0.01304 0.01227 1363 0.01140 0.01053 0.00975 0.00917 0.00884 0.00881 0.00899 0.00933 1364 0.00974 0.01005 0.01039 0.01071 0.01126 0.01222 0.01352 0.01526 1365 0.01714 0.01887 0.02046 0.02166 0.02269 0.02367 0.02461 0.02563 1366 0.02663 0.02748 0.02821 0.02876 0.02913 0.02932 0.02931 0.02904 1367 0.02863 0.02807 0.02750 0.02705 0.02669 0.02648 0.02632 0.02605 1368 0.02574 0.02532 0.02489 0.02449 0.02408 0.02374 0.02333 0.02274 1369 0.02201 0.02110 0.02009 0.01904 0.01798 0.01690 0.01598 0.01525 1370 0.01477 0.01462 0.01461 0.01468 0.01463 0.01424 0.01360 0.01259 1371 0.01148 0.01044 0.00953 0.00889 0.00845 0.00814 0.00799 0.00790 1372 0.00791 0.00802 0.00815 0.00825 0.00825 0.00801 0.00764 0.00712 1373 0.00655 0.00605 0.00562 0.00528 0.00506 0.00493 0.00490 0.00495 1374 0.00503 0.00507 0.00507 0.00490 0.00472 0.00457 0.00452 0.00469 1375 0.00496 0.00529 0.00564 0.00585 0.00607 0.00633 0.00668 0.00722 1376 0.00776 0.00816 0.00835 0.00817 0.00775 0.00712 0.00640 0.00578 1377 0.00526 0.00481 0.00453 0.00443 0.00451 0.00483 0.00522 0.00557 1378 0.00590 0.00607 0.00627 0.00663 0.00705 0.00760 0.00810 0.00836 1379 0.00842 0.00808 0.00760 0.00715 0.00676 0.00656 0.00645 0.00633 1380

Caic Number: GEO.HBIP.02.06 0.00623 0.00449 0.00358

-0.00040

-0.00627

-0.00936

-0.00981

-0.00894

-0.01156

-0.01089

-0.01538

-0.01520

-0.01410

-0.01449

-0.01750

-0.01321

-0.01300

-0.01305

-0.01443

-0.01199

-0.01162

-0.01101

-0.01065

-0.00959

-0.00884

-0.00762

-0.00945

-0.01169

-0.01502

-0.01412

-0.01071

-0.00924

-0.01038

-0.00957

-0.00944

-0.01038

-0.01045

-0.00908

-0.00641

-0.00224 0.00026 0.00240 0.00445 0.00548 0.00577

-0.01030

-0.01263

-0.01230

-0.00936

-0.00643

-0.00266 0.00028 0.00164 0.00310 0.00429 0.00502 0.00554 0.00600 0.00643 0.00678 0.00709 0.00726 0.00737 0.00739 0.00732 0.00714 0.00687 0.00654 0.00617 0.00575

0. 00530 0.00484 0.00437 0.00607 0.00430 0.00336

-0.00146

-0.00664

-0.00934

-0.00935

-0.00946

-0.01157

-0.01158

-0.01523

-0. 01510

-0.01418

-0.01501

-0.01717

-0. 01281

-0.01301

-0.01333

-0.01452

-0.01168

-0.01130

-0.01102

-0.01048

-0.00971

-0. 00859

-0.00765

-0. 00985

-0.01203

-0.01539

-0.01377

-0.01034

-0. 00918

-0.01031

-0.00949

-0.00958

-0.01031

-0.01035

-0.00879

-0.00600

-0.00196 0.00047 0.00255 0.00447

0. 00558 0.00600

-0.01215

-0.01259

-0.01206

-0.00890

-0.00594

-0.00235

-0.00004 0.00179 0.00326 0.00441 0.00509 0.00559 0.00606 0.00647 0.00682 0.00711 0.00728 0.00737 0.00738 0.00730 0.00711 0.00683 0.00650 0.00612 0.00569 0.00524 0.00477 0.00431 0.00590 0.00421 0.00316

-0.00248

-0.00703

-0.00931

-0.00882

-0.01000

-0.01149

-0.01245

-0.01505

-0.01492

-0.01424

-0.01563

-0.01669

-0.01250

-0.01292

-0.01359

-0.01450

-0.01152

-0.01097

-0.01101

-0.01028

-0.00983

-0.00836

-0.00775

-0.01023

-0.01241

-0.01561

-0.01340

-0.01002

-0.00915

-0. 01015

-0.00940

-0.00975

-0.01028

-0.01025

-0.00848

-0.00554

-0.00171 0.00068 0.00273 0.00447 0.00566 0.00661

-0.01269

-0.01260

-0.01177

-0. 00848

-0.00542

-0.00206 0.00021 0.00195 0.00342 0.00453 0.00517 0.00565 0.00613 0.00652 0.00688 0.00713 0.00730 0.00738 0.00738 0.00729 0.00708 0.00679 0.00645 0.00607 0.00564 0.00518 0.00472 0.00426 0.00575 0.00557 0.00426 0.00433 0.00301 0.00277

-0.00341 -0.00421

-0.00760 -0.00817

-0.00946 -0.00965

-0.00841 -0.00812

-0.01052 -0.01095

-0.01131 -0.01108

-0.01342 -0.01433

-0.01499 -0.01498

-0.01469 -0.01445

-0.01419 -0.01411

-0.01629 -0.01689

-0.01611 -0.01548

-0.01230 -0.01224

-0.01271 -0.01251

-0.01377 -0.01389

-0.01433 -0.01401

-0.01160 -0.01176

-0.01080 -0.01071

-0.01099 -0.01095

-0.01006 -0.00986

-0.00989 -0.00987

-0.00819 -0.00804

-0.00792 -0.00815

-0.01056 -0.01084

-0.01280 -0.01321

-0.01561 -0.01545

-0.01296 -0.01249

-0.00976 -0.00955

-0.00923 -0.00937

-0.00995 -0.00975

-0.00934 -0.00930

-0.01000 -0.01024

-0.01042 -0.01057

-0.01021 -0.01013

-0.00820 -0.00790

-0.00499 -0.00439

-0.00140 -0.00106 0.00095 0.00125 0.00304 0.00340 0.00457 0.00472 0.00580 0.00591 0..00636 0.00728

-0.01329 -0.01333

-0.01259 -0.01257

-0.01148 -0.01115

-0.00815 -0.00786

-0.00491 -0.00442

-0.00178 -0.00150 0.00047 0.00073 0.00214 0.00235 0.00358 0.00375 0.00463 0.00474 0.00524 0.00532 0.00571 0.00577 0.00619 0.00624 0.00656 0.00661 0.00691 0.00696 0.00715 0.00717 0.00731 0.00733 0.00738 0.00738 0.00737

.000736 0.00726 0.00724 0.00704 0.00702 0.00675 0.00671 0.00641 0.00636 0.00601 0.00596 0.00558 0.00553 0.00512 0.00507 0.00466 0.00460 0.00420 0.00414 0.00537 0.00429 0.00227

-0.00491

-0. 00870

-0.00992

-0.00806

-0.01125

-0.01078

-0.01497

-0.01507

-0.01422

-0.01402

-0.01733

-0.01484

-0.01237

-0.01245

-0.01402

-0.01356

-0. 01191

-0. 01078

-0.01093

-0.00969

-0.00971

-0.00790

-0.00841

-0.01105

-0.01364

-0. 01518

-0. 01203

-0.00942

-0.00968

-0.00966

-0.00932

-0.01043

-0.01063

-0.00997

-0.00755

-0.00376

-0.00070 0.00154 0.00368 0.00485

0. 00584 0.00555

-0.01317

-0.01267

-0.01086

-0.00764

-0. 00394

-0.00118 0.00100 0.00256 0.00390 0.00482 0.00537 0.00582 0.00629 0.00664 0.00699 0.00719 0.00733 0.00738 0.00735 0.00722 0.00698 0.00667 0.00631 0.00591 0.00547

0. 00501 0.00454 0.00408 0.00514 0.00419 0.00159

-0. 00547

-0.00912

-0.01011

-0.00819

-0.01144

-0.01058

-0.01536

-0.01517

-0. 01406

-0.01400

-0.01759

-0.01422

-0.01258

-0.01249

-0.01412

-0.01303

-0.01198

-0.01089

-0.01088

-0. 00958

-0.00946

-0.00777

-0.00870

-0.01124

-0.01408

-0.01483

-0.01157

-0.00932

-0.01000

-0.00961

-0.00936

-0.01054

-0.01064

-0.00974

-0.00717

-0.00316

-0.00034 0.00184 0.00395 0.00502 0.00578

-0.00468

-0.01288

-0.01270

-0.01051

-0.00737

-0. 00348

-0.00086 0.00125 0.00277 0.00405 0.00490 0.00543 0.00588 0.00634 0.00669 0.00703 0.00722 0.00735 0.00738 0.00735 0.00720 0.00695 0.00663 0.00627 0.00586 0.00541 0.00495 0.00449 0.00402 Rev Number: 0 Sheet Number: 151 of 196 Date: 11/06/02 0.00480 1381 0.00389 1382 0.00065 1383

-0.00590 1384

-0.00930 1385

-0.01005 1386

-0.00850 1387

-0.01154 1388

-0.01061 1389

-0.01546 1390

-0.01522 1391

-0.01406 1392

-0.01417 1393

-0.01765 1394

-0.01369 1395

-0.01282 1396

-0.01273 1397

-0.01429 1398

-0.01248 1399

-0.01186 1400

-0.01096 1401

-0.01079 1402

-0.00956 1403

-0.00916 1404

-0.00767 1405

-0.00907 1406

-0.01146 1407

-0.01458 1408

-0.01448 1409

-0.01113 1410

-0.00927 1411

-0.01024 1412

-0.00959 1413

-0.00938 1414

-0.01048 1415

-0.01056 1416

-0.00943 1417

-0.00681 1418

-0.00266 1419

-0.00003 1420 0.00213 1421 0.00423 1422 0.00525 1423 0.00570 1424

-0.00859 1425

-0.01273 1426

-0.01254 1427

-0.00995 1428

-0.00694 1429

-0.00305 1430

-0.00057 1431 0.00145 1432 0.00294 1433 0.00417 1434 0.00496 1435 0.00548 1436 0.00593 1437 0.00638 1438 0.00673 1439 0.00705 1440 0.00724 1441 0.00736 1442 0.00738 1443 0.00733 1444 0.00717 1445 0.00691 1446 0.00658 1447 0.00622 1448 0.00580 1449 0.00535 1450 0.00489 1451 0.00443 1452 0.00397 1453

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 152 of 196 Date: 11/06/02 0.00391 0.00346 0.00302 0.00260 0.00221 0.00184 0.00151 0.00120 0.00092

0. 00067 0.00045
0. 00027 0.00010

-0.00003

-0.00014

-0.00023

-0.00030

-0.00036

-0.00040

-0.00042

-0.00043

-0.00043

-0.00041

-0.00040

-0.00038

-0.00037

-0.00035

-0.00035

-0.00034

-0.00034

-0.00034

-0.00035

-0.00035

-0.00036

-0.00037

-0.00037

-0.00038

-0.00039

-0.00040

-0.00040

-0.00041

-0.00042

-0.00042

-0.00043

-0.00043

-0.00043 0.003 85 0.00340 0.00297 0.00255 0.00216 0.00180 0.00146 0.00116

0. 00088 0.00064 0.00043 0.00024 0.00008

-0.00005

-0.00016

-0.00024

-0.00031

-0.00036

-0.00040

-0.00042

-0.00043

-0.00042

-0.00041

-0.00040

-0.00038

-0.00036

-0.00035

-0.00035

-0.00034

-0.00034

-0.00034

-0.00035

-0.00035

-0.00036

-0.00037

-0.00037

-0.00038

-0.00039

-0.00040

-0.00040

-0.00041

-0.00042

-0.00042

-0.00043

-0.00043

-0.00043 0.00380 0.00335 0.00292 0.00250 0.00212 0.00176 0.00143 0.00112 0.00085 0.00061 0.00040 0.00022 0.00007

-0.00006

-0.00017

-0.00025

-0.00032

-0.00037

-0.00040

-0.00042

-0.00043

-0.00042

-0.00041

-0.00039

-0.00038

-0.00036

-0.00035

-0.00034

-0.00034

-0.00034

-0.00034

-0.00035

-0.00035

-0.00036

-0.00037

-0.00038

-0.00038

-0.00039

-0.00040

-0.00041

-0.00041

-0.00042

-0.00042

-0.00043

-0.00043

-0.00044

-0.00044 0.00374 0.00329 0.00286

0. 00245 0.00207 0.00171 0.00138
0. 00109 0.00082 0.00058 0.00038 0.00020 0.00005

-0. 00008

-0.00018

-0.00026

-0.00033

-0.00038

-0.00041

-0.00043

-0.00043

-0.00042

-0.00041

-0.00039

-0.00038

-0.00036

-0.00035

-0.00034

-0.00034

-0.00034

-0.00034

-0.00035

-0.00035

-0.00036

-0.00037

-0.00038

-0.00038

-0.00039

-0.00040

-0.00041

-0.00041

-0.00042

-0.00042

-0.00043

-0.00043

-0.00044

-0.00044 0.00369 0.00324 0.00281 0.00240 0.00202 0.00167 0.00135 0.00105 0.00079 0.00056 0.00036 0.00018 0.00003

-0. 00009

-0.00019

-0.00027

-0.00033

-0.00038

-0.00041

-0.00043

-0.00043

-0.00042

-0. 00041

-0.00039

-0.00037

-0.00036

-0.00035

-0.00034

-0.00034

-0.00034

-0.00034

-0.00035

-0.00036

-0.00036

-0.00037

-0.00038 0.00363 0.00318 0.00276 0.00235 0.00198 0.00163 0.00131 0.00102 0.00076 0.00053 0.00033 0.00016 0.00002

-0.00010

-0.00020

-0.00028

-0.00034

-0.00038

-0.00041

-0.00043

-0.00043

-0.00042

-0.00040

-0.00039

-0.00037

-0.00036

-0.00035

-0.00034

-0.00034

-0.00034

-0.00034

-0.00035

-0.00036

-0.00036

-0.00037

-0.00038 0.00351 0.00313 0.00271 0.00231 0.00193 0.00159 0.00127 0.00098 0.00073 0.00050 0.00031 0.00014 0.00000

-0.00012

-0.00021

-0.00029

-0.00035

-0.00039

-0.00042

-0.00043

-0.00043

-0.00042

-0.00040

-0.00039

-0.00037

-0.00036

-0.00035

-0.00034

-0.00034

-0.00034

-0.00034

-0.00035

-0.00036

-0.00036

-0.00037

-0.00038

-0.00039

-0.00039

-0.00040

-0.00041

-0.00041

-0.00042

-0.00043

-0.00043

-0.00043

-0.00044 0.00000 0.00351 3 0.00307 1 0.00265 L 0.00226 0.00189 3 0.00154

0. 00123 0.00095 0.00070 0.00048 0.00029 0.00012

-0.00002

-0.00013

-0. 00022

-0.00030

-0.00035

-0.00039

-0.00042

-0.00043

-0.00043

-0.00042

-0.00040

-0. 00038

-0.00037

-0. 00036

-0.00035

-0.00034

-0.00034

-0.00034

-0.00035

-0.00035

-0.00036

-0.00037

-0.00037

-0.00038

-0.00039

-0.00040

-0.00040

-0.00041

-0.00042

-0.00042

-0.00043

-0.00043

-0.00043

-0.00044 0.00000 1454 1455 1456 1457 1458 1459 1460 1461 1462 1463 1464 1465 1466 1467 1468 1469 1470 1471 1472 1473 1474 1475 1476 1477 1478 1479 1480 1481 1482 1483 1484 1485 1486 1487 1488 1489 1490 1491 1492 1493 1494 1495 1496 1497 1498 1499 1500

-0.00039 -0.00039

-.0.00039 -0.00039

-0.00040 -0.00040

-0.00041 -0.00041

-0.00041 -0.00041

-0.00042 -0.00042

-0.00042 -0.00042

-0.00043 -0.00043

-0.00043 -0.00043

-0.00044 -0.00044

-0.00044 0.00000

-0.00044 -0.00044

Calc Number-GEO.HBIP.02.06 Rev Number: 0 Sheet Number. 153 of 196 Date: 11/06/02 M78Set3.ACC Time history matched to spectrum:::SetTarget:M78.D005RVHWtarget2 11795 0.0050 0.00004 0.00005 0.00004 0.00005 0.00004 0.00004 0.00004 0.0001 0.00004 0.00004 0.00004 0.00004 0.00004 0.00004 0.00003 0.0001 0.00003 0.00003 0.00003 0.00003 0.00003 0.00003 0.00002 0.0001 0.00002 0.00002 0.00001 0.00001 0.00000 0.00000 0.00000 0.0001

-0.00001 -0.00001 -0.00002 -0.00002 -0.00003 -0.00003 -0.00004 -0.0004

-0.00006 -0.00006 -0.00007 -0.00008 -0.00009 -0.00010 -0.00011 -0.000:

-0.00013 -0.00014 -0.00016 -0.00017 -0.00019 -0.00020 -0.00022 -0.000

-0.00025 -0.00027 -0.00029 -0.00031 -0.00034 -0.00036 -0.00039 -0.0004

-0.00044 -0.00047 -0.00050 -0.00053 -0.00057 -0.00060 -0.00064 -0.0000

-0.00072 -0.00076 -0.00080 -0.00084 -0.00089 -0.00093 -0.00099 -0.0014

-0.00108 -0.00112 -0.00118 -0.00122 -0.00127 -0.00131 -0.00135 -0.001

-0.00142 -0.00143 -0.00145 -0.00144 -0.00142 -000136 -0.00128 -0.0011

-0.00093 -0.00061 -0.00016 0.00049 0.00141 0.00270 0.00444 0.006i 0.00984 0.01373 0.01846 0.02415 0.03059 0.03776 0.04517 0.052!

0.05933 0.06497 0.06928 0.07178 0.07277 0.07233 0.07101 0.069!

0.06796 0.06657 0.06523 0.06397 0.06275 0.06152 0.06030 0.0591 0.05795 0.05685 0.05573 0.05461 0.05343 0.05219 0.05084 0.0493 0.04775 0.04595 0.04395 0.04175 0.03936 0.03683 0.03417 0.0314 0.02872 0.02602 0.02332 0.02070 0.01813 0.01566 0.01330 0.0113 0.00909 0.00732 0.00575 0.00444 0.00334 0.00246 0.00178 0.0013 0.00103 0.00099 0.00115 0.00157 0.00219 0.00304 0.00406 0.0052 0.00655 0.00798 0.00946 0.01102 0.01256 0.01409 0.01552 0.016S 0.01792 0.01879 0.01941 0.01977 0.01985 0.01970 0.01927 0.0186 0.01777 0.01672 0.01547 0.01408 0.01254 0.01093 0.00922 0.0074 0.00567 0.00383 0.00194 0.00004 -0.00187 -0.00374 -0.00557 -0.0072

-0.00887 -0.01030 -0.01161 -0.01277 -0.01383 -0.01480 -0.01572 -0.0166

-0.01747 -0.01832 -0.01917 -0.01998 -0.02077 -0.02147 -0.02211 -0.0226

-0.02302 -0.02328 -0.02346 -0.02353 -0.02358 -0.02359 -0.02364 -0.0237

-0.02385 -0.02403 -0.02429 -0.02458 -0.02490 -0.02520 -0.02547 -0.0256

-0.02569 -0.02556 -0.02531 -0.02487 -0.02433 -0.02370 -0.02303 -0.0223

-0.02169 -0.02103 -0.02037 -0.01967 -0.01897 -0.01821 -0.01748 -0.0167

-0.01608 -0.01546 -0.01489 -0.01435 -0.01381 -0.01320 -0.01253 -0.0117

-0.01081 -0.00974 -0.00858 -0.00728 -0.00592 -0.00448 -0.00308 -0.0017

-0.00053 0.00046 0.00114 0.00149 0.00147 0.00110 0.00039 -0.0005

-0.00179 -0.00309 -0.00446 -0.00575 -0.00695 -0.00790 -0.00867 -0.0091

-0.00948 -0.00963 -0.00975 -0.00991 -0.01020 -0.01071 -0.01149 -0.0125

-0.01404 -0.01587 -0.01806 -0.02060 -0.02343 -0.02646 -0.02960 -0.0326

-0.03565 -0.03834 -0.04074 -0.04273 -0.04431 -0.04540 -0.04599 -0.0460

-0.04546 -0.04429 -0.04260 -0.04038 -0.03778 -0.03486 -0.03176 -0.0285

-0.02537 -0.02225 -0.01934 -0.01667 -0.01436 -0.01249 -0.01109 -0.0102

-0.00978 -0.00976 -0.01008 -0.01060 -0.01127 -0.01193 -0.01258 -0.0130

-0.01346 -0.01359 -0.01348 -0.01307 -0.01238 -0.01137 -0.01009 -0.0085

-0.00677 -0.00480 -0.00273 -0.00056 0.00154 0.00355 0.00530 0.0067 0.00766 0.00810 0.00801 0.00740 0.00630 0.00482 0.00301 0.0009

-0.00114 -0.00325 -0.00524 -0.00692 -0.00823 -0.00898 -0.00924 -0.0088

-0.00800 -0.00666 -0.00504 -0.00324 -0.00146 0.00019 0.00150 0.0023 0.00256 0.00202 0.00063 -0.00171 -0.00496 -0.00913 -0.01409 -0.0197

-0.02584 -0.03220 -0.03856 -0.04462 -0.05015 -0.05480 -0.05851 -0.0609

-0.06236 -0.06252 -0.06166 -0.05986 -0.05722 -0.05384 -0.04985 -0.0452'

-0.04037 -0.03521 -0.03008 -0.02521 -0.02068 -0.01674 -0.01325 -0.0102:

-0.00757 -0.00507 -0.00284 -0.00071 0.00107 0.00248 0.00339 0.0036.

0.00343 0.00262 0.00143 0.00002 -0.00149 -0.00287 -0.00401 -0.0047.

-0.00495 -0.00450 -0.00345 -0.00166 0.00067 0.00356 0.00673 0.0100 0.01341 0.01655 0.01943 0.02194 0.02409 0.02588 0.02734 0.0285!

0.02951 0.03032 0.03089 0.03129 0.03131 0.03093 0.02987 0.0280:

0.02518 0.02120 0.01620 0.01010 0.00335 -0.00385 -0.01090 -0.0173'

-0.02259 -0.02614 -0.02794 -0.02748 -0.02531 -0.02132 -0.01642 -0.0110,

-0.00604 -0.00220 0.00009 0.00009 -0.00193 -0.00625 -0.01209 -0.0191:

-0.02641 -0.03314 -0.03874 -0.04223 -0.04361 -0.04221 -0.03859 -0.0326X

-0.02524 -0.01684 -0.00828 -0.00036 0.00649 0.01152 0.01476 0.0158!

0.01523 0.01300 0.00973 0.00592 0.00194 -0.00154 -0.00452 -0.0065:

-0.00784 -0.00838 -0.00858 -0.00869 -0.00897 -0.00979 -0.01102 -0.0128

-0.01488 -0.01690 -0.01847 -0.01911 -0.01865 -0.01656 -0.01310 -0.00791

-0.00181 0.00529 0.01257 0.01954 0.02561 0.03011 0.03285 0.0333:

0.03180 0.02816 0.02294 0.01650 0.00937 0.00217 -0.00476 -0.0107'

-0.01585 -0.01949 -0.02187 -0.02283 -0.02263 -0.02138 -0.01929 -0.01651 204 204 2

0 D2 L2 123 11 168

)3 L3 I0

.2 48 57

.1 11 2

64 48 27 61 1

'3 6

S 2

2 9

6 8

8 0

6 0

9 3

0 9

5 5

3 8

7 3

a 2

9 5

I 5

I S

I 3

9 a

1 2

3 4

5 6

7 8

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66

Caic Number: GEO.HBEP.02.06

-0.01328 -0.00955 0.03432 0.04251 0.06623 0.06095

-0.02943 -0.04567

-0.12666 -0.12890

-0.06608 -0.05171

-0.00975 -0.01464

-0.06989 -0.07540

-0.08494 -0.08213

-0.02671 -0.01643 0.02397 0.02512 0.02888 0.02892 0.00872 0.00384

-0.02622 -0.03003

-0.05233 -0.05224

-0.00929 -0.00008 0.02963 0.02791 0.01124 0.01024 0.00478 0.00469 0.03564 0.04345 0.05480 0.04691

-0.02535 -0.03156

-0.04097 -0.04082

-0.03791 -0.03583

-0.02252 -0.02283

-0.02020 -0.01575 0.02613 0.02866 0.00499 -0.00096

-0.02496 -0.02567

-0.01482 -0.01060 0.03635 0.04438 0.09132 0.09436 0.07181 0.06373 0.00705 0.00148

-0.00927 -0.00743 0.01024 0.01183 0.01343 0.01324 0.02041 0.02243 0.02919 0.02925 0.03950 0.04244 0.05567 0.05645 0.06358 0.06369 0.02433 0.01282

-0.06213 -0.06769

-0.06499 -0.06080

-0.02211 -0.01610 0.00978 0.00995 0.00705 0.00945 0.05381 0.06127 0.09866 0.10216 0.10440 0.09886 0.01777 0.00505

-0.04754 -0.05199

-0.10626 -0.11562

-0.11990 -0.10913

-0.01816 -0.00957 0.01037 0.00998

-0.00282 -0.00536

-0.00027 0.00534 0.06684 0.07616 0.11303 0.11222 0.07532 0.06911 0.05017 0.05112 0.06109 0.06073 0.02491 0.01484

-0.06183 -0.06996

-0.09307 -0.09330

-0.10733 -0.11156

-0.11533 -0.10905

-0.02964 -0.01656 0.08490 0.09924 0.10173 0.09482 0.08484 0.08856

-0.00526 0.05031 0.05329

-0.06155

-0.12807

-0.03828

-0.02139

-0.07982

-0.07803

-0.00677 0.02573 0.02837

-0.00109

-0.03387

-0.05065 0.00854 0.02538 0.00946 0.00540 0.05073 0.03724

-0.03617

-0.04075

-0.03344

-0.02356

-0.01028 0.02953

-0.00662

-0.02584

-0.00567 0.05237 0.09589 0.05513

-0.00311

-0.00515 0.01297 0.01323 0.02434 0.02943 0.04533 0.05721 0.06276 0.00064

-0.07156

-0.05612

-0.01037 0.00944 0.01300 0.06832 0.10514 0.09144

-0.00664

-0.05688

-0.12384

-0.09653

-0.00270 0.00915

-0.00753 0.01206 0.08488 0.10985 0.06347

0. 05258
0. 05936 0.00396

-0.07685

-0.09358

-0.11562

-0.10108

-0.00333 0.11102 0.08871 0.09373

-0.00038 0.05731 0.04328

-0.07664

-0.12384

-0.02671

-0.02942

-0.08309

-0.07238 0.00174 0.02621 0.02698

-0.00579

-0.03781

-0.04719 0.01604 0.02251 0.00875 0.00731 0.05685 0.02625

-0.03 909

-0.04084

-0.03076

-0.02452

-0.00381 0.02855

-0.01153

-0.02549 0.00003 0.06024 0.09571 0.04633

-0.00659

-0.00249 0.01370 0.01354 0.02600 0.02997 0.04798 0.05815 0.06048

-0.01173

-0.07364

-0.05106

-0.00503 0.00846 0.01792 0.07473 0.10766 0.08197

-0.01673

-0.06274

-0.13016

-0.08263 0.00243 0.00801

-0.00903 0.01986 0.09281 0.10601 0.05873 0.05435 0.05686

-0.00753

-0.08233

-0.09420

-0.11911

-0.09150 0.00989 0.11855 0.08481 0.10087 0.00514 0.06308 0.03129

-0.09055

-0.11669

-0.01740

-0.03819

-0.08534

-0.06539 0.00902 0.02659 0.02480

-0.01032

-0.04166

-0. 04215 0.02219 0.01950 0.00803 0.01042 0.06132 0.01464

-0.04077

-0.04090

-0.02815

-0.02532 0.00307 0.02600

-0.01579

-0.02460 0.00635 0.06777 0.09388 0.03753

-0.00904 0.00031 0.01405 0.01417 0.02734 0.03086 0.05032 0.05918 0.05668

-0.02391

-0.07422

-0.04569

-0.00030 0.00730 0.02385 0.08057 0.10938 0.07090

-0.02541 0.01151 0.06713 0.01761

-0.10291

-0.10659

-0.01107

-0.04698

-0.08669

-0.05692 0.01474 0.02718 0.02170

-0.01453

-0.04534

-0.03540 0.02655 0.01683 0.00717 0.01510 0.06349 0.00317

-0.04146

-0.04077

-0.02585

-0.02555 0.00998 0.02197

-0.01915

-0.02312 0.01329 0.07491 0.09038 0.02903

-0.01042 0.00314 0.01413 0.01526 0.02826 0.03236 0.05219 0.06044 0.05105

-0.03534

-0.07342

-0.04003 0.00363 0.00629 0.03076 0.08582 0.11022 0.05838

-0.03243 0.01852 0.06920

0. 00264

-0. 11330

-0.09442

-0.00762

-0.05550

-0.08707

-0.04748

0. 01909 0.02777 0.01790

-0.01857

-0.04853

-0.02748 0.02925 0.01445 0.00629 0.02095 0.06328

-0.00771

-0.04150

-0. 04035

-0.02403

-0.02500 0.01644 0.01689

-0.02179

-0.02105 0.02067 0.08133 0.08541 0.02097

-0.01088

0. 00582 0.01397 0.01667 0.02884 0.03428 0.05368 0.06166 0.04376

-0.04577

-0.07147

-0.03418 0.00667 0.00570 0.03824 0.09053 0.10983 0.04502

-0.03829

-0.08668

-0.13325

-0.04064 0.00978 0.00234

-0.00756 0.04738

0. 10951 0.08863
0. 05055 0.05956 0.04162

-0.04205

-0.09148

-0. 09995

-0.12219

-0. 05602 0.05327 0.11654 0.08153 0.12876 Rev Number: 0 Sheet Number: 154 of 196 Date: 11/06/02 0.02627 67 0.06891 68

-0.01316 69

-0.12130 70

-0.08058 71

-0.00734 72

-0.06314 73

-0.08655 74

-0.03720 75 0.02206 76 0.02844 77 0.01351 78

-0.02242 79

-0.05096 80

-0.01857 81 0.03015 82 0.01266 83 0.00539 84 0.02803 85 0.06026 86

-0.01723 87

-0.04130 88

-0.03935 89

-0.02295 90

-0.02317 91 0.02191 92 0.01111 93

-0.02369 94

-0.01827 95 0.02841 96 0.08690 97 0.07913 98 0.01362 99

-0.01043 100 0.00821 101 0.01372 102 0.01846 103 0.02910 104 0.03676 105 0.05480 106 0.06285 107 0.03472 108

-0.05471 109

-0.06861 110

-0.02814 111 0.00869 112 0.00591 113 0.04602 114 0.09483 115 0.10796 116 0.03131 117

-0.04312 118

-0.09643 119

-0.12795 120

-0.02865 121 0.01041 122

-0.00021 123

-0.00454 124 0.05717 125 0.11209 126 0.08195 127 0.04995 128 0.06065 129 0.03386 130

-0.05241 131

-0.09253 132

-0.10340 133

-0.11967 134

-0.04294 135 0.06942 136 0.10965 137 0.08253 138 0.13845 139

-0.06957 -0.07770

-0.13419 -0.13518

-0.06821 0.00606 0.00649

-0.00970 0.02847 0.09968 0.10100 0.05491 0.05622 0.05312

-0.01925

-0.08656

-0.09535

-0.12166

-0.08066 0.02355 0.12231 0.08238 0.10923

-0.05407 0.00845 0.00457

-0.00921 0.03774 O.10532

0. 09511 0.05223 0.05803 0.04803

-0.03085

-0.08952

-0.09730

-0.12270

-0.06869 0.03819 0.12097 0.08128 0.11879

Calc Number: GEO.HBIP.02.06 0.14750 0.15733 0.01891

-0.09321

-0.04450

-0.07705

-0.12769

-0.02706 0.15382 0.12007 0.02519

-0.00432 0.09913 0.20597 0.26186 0.11398

-0.14993

-0.30971

-0.28164

-0.12249

-0.00596 0.05232 0.06595 0.05493 0.06661 0.17723 0.24483 0.13453

-0.09055

-0.09466 0.01794

-0.05745

-0.26287

-0.32807

-0.16326

-0.00399 0.05350 0.19654 0.30586 0.23464 0.05834

-0.04706

-0.19013

-0.30667

-0.17770

-0.21425

-0.40616

-0.16456 0.33958 0.48137 0.19641

-0.04969

-0.11670

-0.04192

-0.05085

-0.27812

-0.26997 0.03464 0.29957 0.37297 0.34636 0.17471

-0.11825

-0.30177

-0.20699 0.00995 0.13475 0.11128 0.03274

-0.09196

-0.20869

-0.16318

-0.14955 0.15524 0.16156 0.14786 0.13571

-0.00318 -0 :02422

-0.09246 -0.08887

-0.04059 -0.03899

-0.08736 -0.09742

-0.12538 -0.12036

-0.00208 0.02402 0.16295 0.16760 0.10626 0.09239 0.01665 0.00903 0.00158 0.00997 0.11573 0.13167 0.21631 0.22621 0.25840 0.25082 0.08028 0.04542

-0.17697 -0.20217

-0.31813 -0.32324

-0.26501 -0.24664

-0.10321 -0.08512 0.00351 0.01225 0.05640 0.05967 0.06561 0.06494 0.05301 0.05151 0.07548 0.08627 0.19230 0.20612 0.24223 0.23661 0.10666 0.07696

-0.10758 -0.11990

-0.07930 -0.06283 0.02255 0.02334

-0.08213 -0.10846

-0.28251 -0.29937

-0.31896 -0.30586

-0.13584 -0.10952 0.00445 0.01129 0.06568 0.07985 0.21690 0.23613 0.30770 0.30639 0.21399 0.19192 0.04023 0.02386

-0.05879 -0.07187

-0.21387 -0.23678

-0.30164 -0.29193

-0.16177 -0.15002

-0.24206 -0.27215

-0.40592 -0.39711

-0.10151 -0.03512 0.16618 0.16890 0.16962 0.12084 0.10362 0.08425

-0.04338 -0.06015 -0.07371

-0.08276 -0.07510 -0.06662

-0.04014 -0.04371 -0.04972

-0.10651 -0.11445 -0.12070

-0.11245 -0.10154 -0.08736 0.05058 0.07643 0.10057 0.16758 0.16361 0.15605 0.07922 0.06669 0.05513 0.00239 -0.00290 -0.00651 0.02097 0.03403 0.04899 0.14642 0.16016 0.17271 0.23584 0.24459 0.25227 0.23851 0.22173 0.20026 0.01040 -0.02436 -0.05799

-0.22556 -0.24696 -0.26637

-0.32461 -0.32252 -0.31682

-0.22692 -0.20628 -0.18508

-0.06853 -0.05336 -0.03970 0.02050 0.02813 0.03523 0.06214 0.06390 0.06508 0.06395 0.06264 0.06099 0.05068 0.05081 0.05222 0.09905 0.11331 0.12881 0.21822 0.22835 0.23623 0.22791 0.21593 0.20054 0.04603 0.01497 -0.01521

-0.12682 -0.12887 -0.12592

-0.04612 -0.02982 -0.01464 0.01984 0.01218 0.00017

-0.13570 -0.16324 -0.19027

-0.31310 -0.32352 -0.33044

-0.28861 -0.26799 -0.24427

-0.08522 -0.06323 -0.04417 0.01713 0.02261 0.02850 0.09620 0.11426 0.13388 0.25371 0.26929 0.28249 0.30189 0.29425 0.28345 0.16893 0.14553 0.12233 0.00946 -0.00345 -0.01496

-0.08683 -0.10373 -0.12291

-0.25784 -0.27620 -0.29075

-0.27767 -0.26007 -0.23975

-0.14448 -0.14758 -0.15787

-0.30319 -0.33312 -0.35992

-0.37917 -0.35245 -0.31696 0.03302 0.10108 0.16694 0.45534 0.47828 0.49233 0.40103 0.36264 0.32137 0.08304 0.05008 0.02035

-0.09255 -0.10170 -0.10859

-0.10492 -0.09612 -0.08465

-0.00897 -0.00589 -0.00868

-0.13307 -0.16463 -0.19617

-0.31892 -0.32085 -0.31673

-0.17722 -0.13849 -0.09692 0.15788 0.19368 0.22583 0.34284 0.35228 0.36002 0.37185 0.36920 0.36538 0.30825 0.28868 0.26544 0.06065 0.02128 -0.01658

-0.20483 -0.23097 -0.25521

-0.29645 -0.28482 -0.26979

-0.12558 -0.09683 -0.06850 0.07337 0.09050 0.10541 0.13975 0.13674 0.13196 0.08682 0.07777 0.06791

-0.01029 -0.02588 -0.04175

-0.14572 -0.16301 -0.17895

-0.20299 -0.19541 -0.18670

-0.15377 -0.15324 -0.15312

-0.13120 -0.12080 -0.10815 0.16804 0.06333

-0. 08396

-0.05816

-0. 05759

-0.12517

-0.07017 0.12210

0. 14575 0.04437

-0.00818

0. 06515 0.18441 0.25810 0.17483

-0.09038

-0.28346

-0.30795

-0.16381

-0.02735 0.04167

0. 06572 0.05910 0.05514 0.14495 0.24171 0.18181

-0.04355

-0.11885

-0.00124

-0.01567

-0.21630

-0.33365

-0.21842

-0.02792 0.03523 0.15445 0.29313 0.26976 0.09973

-0.02576

-0.14389

-0.30109

-0.21838

-0.17188

-0.38219

-0.27344 0.22960 0.49761 0.27881

-0.00627

-0.11332

-0.07148

-0.01701

-0.22647

-0.30679

-0.05363 0.25431 0.36595 0.36015 0.23861

-0.05298

-0.27592

-0.25145

-0.04091 0.11785 0.12581 0.05721

-0.05813

-0.19247

-0.17778

-0.15291

-0.09337 Rev Number: 0 Sheet Number: 155 of 196 Date: 11/06/02 0.16399 140 0.04131 141

-0.09033 142

-0.05061 143

-0.06689 144

-0.12756 145

-0.04982 146 0.13995 147 0.13354 148 0.03439 149

-0.00745 150 0.08206 151 0.19546 152 0.26153 153 0.14577 154

-0.12101 155

-0.29800 156

-0.29606 157

-0.14282 158

-0.01615 159 0.04738 160 0.06603 161 0.05701 162 0.05993 163 0.16126 164 0.24463 165 0.15963 166

-0.06886 167

-0.10812 168 0.00982 169

-0.03510 170

-0.24060 171

-0.33287 172

-0.19108 173

-0.01470 174 0.04352 175 0.17553 176 0.30097 177 0.25335 178 0.07833 179

-0.03624 180

-0.16660 181

-0.30634 182

-0.19718 183

-0.19063 184

-0.39777 185

-0.22210 186 0.28734 187 0.49363 188 0.23716 189

-0.02953 190

-0.11609 191

-0.05670 192

-0.03136 193

-0.25403 194

-0.29108 195

-0.00946 196 0.27875 197 0.37025 198 0.35399 199 0.20819 200

-0.08651 201

-0.29140 202

-0.23042 203

-0.01475 204 0.12764 205 0.11889 206 0.04544 207

-0.07481 208

-0.20238 209

-0.16989 210

-0.15182 211

-0.07650 212 0.38543 0.46119 0.15671

-0.06674

-0.11517

-0.02805

-0.07504

-0.29733

-0.24358 0.07773 0.31685 0.37382 0.33663 0.13826

-0.14825

-0.30540

-0.18123 0.03294 0.13901 0.10349 0.01912

-0.10970

-0.21032

-0.15846

-0.14544 0.42418 0.43437 0.11864

-0.0809a

-0.11131

-0.01656

-0.10278

-0.31122

-0.21258 0.11907 0.33110 0.37332 0.32423 0.10004

-0.17676

-0.30360

-0.15400 0.05408 0.14067 0.09530 0.00470

-0.12758

-0.20843

-0.15530

-0.13944

Caic Number: GEO.HBIP.02.06

-0.05785 0.10932 0.19142 0.12909

-0.00303

-0.03927

-0.01946 0.20898 0.32835 0.09600

-0.05252

-0.12017

-0.29291

-0.32207

-0.11635

-0.17199

-0.22344 0.04620

-0.04065

-0.14507 0.18872 0.30051 0.17819

-0.00859

-O.07848

-0.16477

-0.37654

-0.42321

-0.17516

-0.19075 0.20289 0.09720 0.01743

0. 05021 0.44922 0.28699 0.13767 0.16947

-0.46652 0.08193 0.54528 0.46145 0.37012

-0.13139 0.30735

-0.06806

-0.52375 0.28844 0.34087 0.39849

-0.04593 0.05743

-0.15175 0.11029 0.08993

-0.40208

-0.37998

-0.32331

-0.82453

-0.39910

-0.13469 0.15907 0.36049

-0.07220

-0.06225 0.22886 0.03129 0.24820 0.02930 0.33853

-0.39054 0.223 88 0.49138

-0.03745 0.12561 0.19155 0.11198

-0.01201

-0.04146

-0.00329 0.24184 0.31328 0.06591

-0.05998

-0.13501

-0.31396

-0.30190

-0.09813

-0.20093

-0.19375 0.06378

-0.07327

-0.12230 0.22685 0.29730 0.15126

-0.02374

-0.08371

-0.19722

-0.38377

-0.40772

-0.18438

-0.12312 0.21171 0.07214

-0.02663 0.12038 0.49301 0.31807

0. 05412 0.10396

-0.47381 0.18542

0. 54030
0. 55514 0.22542

-0.02930 0.24476

-0. 10543

-0.44545 0.33665 0.30622 0.39040

-0.08073 0.05915

-0.16146 0.16224

-0.01595 0.14027 0.18916 0.09374

-0.01908

-0.04326 0.0172C 0.27152 0.29197 0.03887

-0.06668

-0. 15234

-0.33145

-0.27806

-0.08617

-0.22747

-0.15908 0.07322

-0.10386

-0.09146 0.25772 0.29142 0.12410

-0.03626

-0.08901

-0.23244

-0.38987

-0.38298

-0.20452

-0.04838 0.21393

0. 05203

-0.06994 0.19138 0.51755 0.35794

-0.00467 0.00631

-0.45562 0.28334 0.52662 0.67330

-0.00968 0.08339 0.15964

-0.16425

-0.33130 0.37459 0.28361 0.36725

-0.09929 0.04652

-0.15644 0.20592 0.00641 0.15357 S 0.18437 1 0.07466 3 -0.02452

-0.04461 0.04247 0.29657 7 0.26474 7 0.01577

-0.07332

-0. 17238

-0.34396

-0.25142

-0.08208

-0.24805

-0.12150 0.07314

-0.12934

-0.05237 0.27878 0.28225 0.09841

-0. 04588

-0. 09310

-0.26876

-0.39773

-0.34461

-0.23477 0.02239 0.21195 0.04636

-0.10232 0.24501 0.50144 0.40630 0.00102

-0.11032

-0. 41573 0.37422 0.49597 0.73343 0.00674 0.16676 0.06345

-0.25436

-0.19916 0.40705 0.28983 0.32000

-0.09330 0.01802

-0.13442 0.23152

-0.14546

-0.49957

-0.27237

-0.50152

-0.79590

-0.17704

-0.11788 0.33056 0.21863

-0.17058 0.07803 0.15295 0.08359 0.26923 0.07310 0.01817 0.17478 0.41436 0.43948 0.02887 0.16514 0.17727

0. 05575

-0.02870

-0.04470 0.07148 0.31634 0.23340

-0. 00388

-0.08026

-0.19462

-0.35125

-0.22312

-0.08574

-0.26179

-0.08274 0.06442

-0.14891

-0.00762 0.29267 0.26927 0.07380

-0.05353

-0.09911

-0.30276

-0.40553

-0.30189

-0.26262 0.08699 0.20266 0.04634

-0.11765 0.28950 0.46431 0.43895 0.03495

-0.23180

-0.34535 0.43391 0.45307 0.88802

-0.06479 0.22306

-0.01358

-0.35230

-0.06866 0.42566 0.31061 0.25636

-0.07273

-0.01727

-0.09908 0.23923

-0.21018

-0.50677

-0.27572

-0.57082

-0.69139

-0.15386

-0.07974 0.39432 0.15617

-0.17552 0.12180 0.10929 0.11540 0.24148 0.10451

-0.22988 0.24599 0.44646 0.33156

0. 05081 0.17510 0.16830 0.03810

-0.03199

-0.04299 0.10402 0.32979 0.19926

-0. 01999

-0.08804

-0.21889

-0.35249

-0.19411

-0.09842

-0.26574

-0.04494 0.04660

-0.16060 0.04219 0.29990 0.25132 0.05053

-0.06010

-0.10738

-0.33019

-0.41528

-0.25605

-0.27532 0.13422 0.18351

0. 05279

-0.10271 0.32563 0.39768 0.41332 0.10305

-0.32451

-0.25903 0.49165 0.42836 0.74973

-0.14720 0.27843

-0.05167

-0.44787

0. 05040 0.42682 0.34323 0.17539

-0.03902

-0.05451

-0.05608 0.23342

-0.26842

-0.49172

-0.27092

-0.63173

-0.63941

-0.12005

-0.02371 0.41322 0.09581

-0.16517 0.15925 0.06832 0.14999 0.18345 0.14907

-0.43391 0.24345 0.45486 0.20473 0.07181

0. 18296
0. 1572 0.02196

-0.03466

-0.03872 0.13853 0.33 655 0.1638B

-0. 03316

-0.09705

-0.24402

-0.34798

-0.16587

-0.11777

-0.26092

-0.00971 0.02206

-0.16415 0.09319 0.30240 0.22977 0.02910

-0.06611

-0.12012

-0.35220

-0.42279

-0.21536

-0.27209 0.16917 0.15909 0.05602

-0.07108 0.35924 0.33778 0.35820 0.16522

-0.40592

-0.15342 0.52833 0.37657 0.80762

-0.19234 0.31436

-0.07931

-0.51867

0. 15815 0.41331 0.37197 0.09151 0.00232

-0.09519

-0.00172 0.20601

-0.32605

-0.46344

-0.26888

-0.69612

-0.55538

-0.11809 0.04354 0.41779 0.04047

-0.14031 0.19541 0.04068 0.18317 0.11419 0.19404

-0.58110 0.20398 0.44572 0.07671 Rev Number: 0 Sheet Number: 156 of 196 Date: 11/06/02 70.09132 213 0.18843 214 0.14409 215 60.00840 216 B -0.03708 217 2-0.03098 218 30.17402 219 0.33599 220 0.12923 221

-0.04380 222 i-0.10760 223

-0.26911 224 3 -0.33760 225

-0.13933 226

-0.14347 227

-0.24613 228 0.02117 229

-0.00793 230

-0.15899 231 0.14294 232 0.30276 233 0.20497 234 0.00908 235

-0.07236 236

-0.13977 237

-0.36639 238

-0.42653 239

-0.18873 240

-0.24015 241 0.19067 242 0.12768 243 0.04266 244

-0.01628 245 0.40552 246 0.30344 247 0.25047 248 0.17925 249

-0.44965 250

-0.02514 251 0.53278 252 0.42298 253 0.53742 254

-0.18688 255 0.32030 256

-0.06896 257

-0.54203 258 0.23307 259 0.37946 260 0.39009 261 0.01614 262 0.03496 263

-0.12733 264 0.05646 265 0.15033 266

-0.35771 267

-0.42008 268

-0.31063 269

-0.67997 270

-0.48786 271

-0.13434 272 0.10222 273 0.39869 274

-0.01973 275

-0.10598 276 0.22021 277 0.03166 278 0.22162 279 0.06612 280 0.27974 281

-0.53132 282 0.20369 283 0.46377 284

-0.01150 285 0.01508 -0.07083

-0.45208 -0.46949

-0.33450 -0.30843

-0.39811 -0.43419

-0.77791 -0.73146

-0.30679 -0.25227

-0.14444 -0.13466 0.22558 0.26756 0.31557 0.26819

-0.11349 -0.14923

-0.01480 0.03001 0.22258 0.19607 0.04323 0.06208 0.27067 0.28508 0.03032 0.05473 0.31860 0.24113

-0.18248 0.04923 0.28397 0.36355 0.50840 0.50631

Calc Number: GEO.HIP.02.06

-0.07384

-0.57201

-0.51279

-0.23164

-0.21027 0.00046

-0.01955

-0.07300

-0. 48483

-0. 29686

0. 03 172

-0. 05296 0.2 9731

0. 68249 0.05672 0.3 8995

-0.22535

-0.32929

-0. 28086

-0.07454

-0. 02728

-0. 02766

-0. 02897

-0.06892 0.34737

0. 52210

-0.03904

-0.56360

-0.25161

-0. 17143

-0. 06514 0.24829 0.26980 0.24756

0. 02171

-0. 04525 0.14519

-0. 05325

-0. 09519

0. 04009
0. 04934
0. 05510 0.08356 0.27789 0.38801
0. 22806
0. 14571 0.07130

-0.06673

-0.37134

-0.33 930 0.13972 0.17071

0. 05086 0.22381
0. 17601

-0.3 1827

-0. 49687

-0. 16068 0.01553

-0. 33502

-0. 40955

-0.10164 0.20344

0. 32175

-0. 00753

0. 05914 0.42341
0. 56382
0. 38936

-0. 20480

-0.34189

0. 04603

-0. 12648

-0. 56747

-0. 50449

-0. 10898

-0. 24885

-0. 00102

-0.02648

-0.10836

-0. 44 958

-0. 26981

0. 08555

-0. 06236

0. 35900
0. 64168
0. 06663
0. 363 38

-0. 26937

-0. 35033

-0. 26550

-0. 05337

-0. 01816

-0. 03438

-0.04697

-0.04464

0. 39043 0.50945

-0.14935

-0. 55627

-0.22419

-0.16583

-0. 02697

0. 26764 0.27135
0. 22818

-0. 00810

-0. 02150

0. 14191

-0. 07786

-0.08067 0.05105 0.04559 0.05752

0. 09661
0. 30721
0. 37569
0. 21311
0. 13 842
0. 05916

-0. 09607

-0. 40392

-0. 28536 0.17711

0. 14393
0. 06284 0.24451
0. 12947

-0.37561

-0. 47252

-0. 11322

-0. 00616

-0. 37596

-0. 38008

-0. 06116 0.23575

0. 29883

-0.03783 0.10574 0.45824

0. 56527
0. 32186

-0.26318

-0.30404

0. 08248

-0. 18456

-0. 57079

-0. 51569

-0.01638

-0.26637

-0. 01879

-0.03290

-0. 15755

-0.39938

-0. 23472 0.12909

-0. 04461 0.42364 0.57279 0.10711 0.31011

-0.29875

-0.37253

-0. 25601

-0.04292

-0. 01205

-0. 03754

-0. 06645

-0. 00931

0. 42598
0. 48190

-0. 25291

-0. 53344

-0.20492

-0.15933

0. 01563 0.28027 0.27484 0.20489

-0. 03417

0. 00659
0. 12937

-0. 09710

-0. 06417

0. 05884
0. 04298 0.05948
0. 11338 0.33394
0. 35837 0.20033
0. 13097 0.04620

-0. 12910

-0. 42902

-0. 22443

0. 20444
0. 11662
0. 07982 0.26019
0. 07547

-0.42515

-0.44033

-0. 07029

-0. 03704

-0. 41022

-0.34546

-0.02122

0. 26520
0. 26677

-0. 05794

0. 15502 0.48908
0. 56317 0.24718

-0.31185

-0.25824

0. 11030

-0.26889

-0.57 946

-0. 53499

0. 03249

-0.23 844

-0. 02763

-0.03930

-0.23206

-0. 35561

-0. 19144

0. 14930
0. 00102
0. 49474
0. 47459 0.1673 0
0. 22563

-0. 31657

-0.39762

-0.25774

-0.05077

-0. 00855

-0. 03043

-0. 07897

0. 04128 0.45555
0. 43558

-0. 34201

-0. 493 58

-0.19337

-0. 15334 0.06110 0.28564 0.27893

0. 17853

-0. 05470

0. 03745 0.10702

-0.10981

-0.04610

0. 06295 0.04232 0.06080
0. 13428 0.35668 0.33716 0.18913
0. 122 96
0. 03 244

-0. 16623

-0. 44391

-0. 15852 0.22087

0. 09123
0. 10030
0. 26898
0. 01505

-0.46450

-0. 40166

-0. 033 02

-0. 07907

-0. 43440

-0.30732

0. 01845
0. 29144
0. 22555

-0. 06542

0. 20426 0.51465
0. 55819
0. 16895

-0.34927

-0. 20665

0. 12890

-0.37138 -0.46721

-0.59510 -0.59215

-0.55001 -0.52795 0.03527 -0.00689

-0.19015 -0.12909

-0.04123 -0.03737

-0.05025 -0.05004

-0. 31624

-0. 32119

-0. 14777

0. 14334
0. 06131 0.56413 0.36222 0.23714
0. 12810

-0. 32622

-0. 41178

-0. 25538

-0. 06495

-0.00890

-0. 02118

-0.08813 0.10006 0.47879 0.37156

-0. 41757

-0. 44475

-0.18705

-0.14495

0. 10675
0. 28612 0.27987
0. 14938

-0. 06889 0.06839 0.07819

-0.11677

-0.02736

0. 06408
0. 04313 0.06234
0. 15860
0. 37472
0. 31376 0.17929
0. 11434
0. 01726

-0. 20619

-0.44779

-0. 09109

0. 22726 0.06955
0. 12366 0.26982

-0.04992

-0. 49351

-0.35801

-0.00312

-0.12927

-0.44807

-0.26684 0.05748 0.31270

0. 17875

-0. 06131

0. 25311 0.53467
0. 54628
0. 08863

-0. 37462

-0. 15206

0. 13 682

-0.39578

-0. 30984

-0. 10768

0. 103 02
0. 12285
0. 62348
0. 25056
0. 30231
0. 02239

-0. 32 668

-0. 39448

-0. 22176

-0.06469

-0.00875

-0.01279

-0. 09157

0. 16619
0. 49912 0.28630

-0. 47837

-0.39065

-0.18274

-0.13427

0. 14955 0.28276
0. 27755
0. 11834

-0. 07477

0. 09715
0. 04495

-0. 11811

-0. 00852 0.06229 0.04546 0.06461

0. 18627 0.3 8728
0. 28984
0. 16999
0. 10465
0. 00031

-0. 24871

-0. 43 869

-0. 02533

0. 22406
0. 05448
0. 14871 0.26085

-0. 11813

-0. 51075

-0. 31063 0.01683

-0. 18235

-0. 45157

-0.22554

0. 09580
0. 32792 0.12a6l

-0. 04483

0. 29975
0. 54780
0. 52442
0. 009 84

-0. 38605

-0. 09765 0.13159

-0. 53 876

-0. 57235

-0.4638S

-0. 0678C

-0. 06201

-0. 02905

-0.05503

-0.46110

-0.3 0721

-0. 06551

0. 04751 0.18459
0. 66815
0. 15209
0. 353 81

-0. 07810 m-0.32645

-0. 36630

-0. 18047

-0.05949

-0. 01126

-0. 00783

-0.08891

0. 23302 0.51402 0.18703

-0. 52274

-0.33680

-0.18012

-0. 11852

0. 18852
0. 27748 0.27231
0. 08613

-0. 07296

0. 12112
0. 01008

-0. 11460

0. 00959
0. 05871
0. 04857 0.06819
0. 21601
0. 39366
0. 26656 0.16140 0.09423

-0. 01904

-0.29154

-0. 41739 0.03668 0.. 21268

0. 04574
0. 17442 0.24244

-0.18700

-0. 51698

-0.26103

0. 02708

-0. 23650

-0. 44 669

-0. 183 83 0.13316 0.33546

0. 07861

-0. 01860

0. 343 87
0. 55670 0.49224

-0. 06655

-0. 38434

-0. 04498

0. 11722 Rev Number: 0 Sheet Number. 157 of 196 Date: 11/06/02

-0.57291 286 i-0.54506 287

-0.35943 288 I-0.14361 289

-0.02445 290

-0.02679 291

-0.06033 292

-0.48826 293

-0.30526 294

-0.01905 295

-0.00980 296 0.24125 297 0.68890 298 0.08784 299 0.38549 300

-0.15954 301

-0.32576 302

-0.32318 303

-0.12567 304

-0.04499 305

-0.01958 306

-0.01565 307

-0.08326 308 0.29320 309 0.52288 310 0.07602 311

-0.55186 312

-0.29075 313

-0.17586 314

-0.09504 315 0.22149 316 0.27274 317 0.26204 318 0.05340 319

-0.06262 320 0.13742 321

-0.02303 322

-0.10669 323 0.02596 324 0.05410 325 0.05191 326 0.07437 327 0.24702 328 0.39356 329 0.24619 330 0.15341 331 0.08310 332

-0.04122 333

-0.33320 334

-0.38348 335 0.09215 336 0.19413 337 0.04502 338 0.20009 339 0.21382 340

-0.25453 341

-0.51192 342

-0.21039 343 0.02659 344

-0.28864 345

-0.43208 346

-0.14253 347 0.16911 348 0.33340 349 0.03253 350 0.01693 351 0.38525 352 0.56182 353 0.44614 354

-0.13877 355

-0.36894 356 0.00330 357 0.09218 358

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 158 of 196 Date: 11/06/02 0.06491 0.04016 0.02209 0.01995 0.02802 0.05040 0.07791 0.10432 359 0.12772 0.13887 0.14399 0.14134 0.13608 0.13384 0.13293 0.13763 360 0.14329 0.14812 0.15039 0.14604 0.13631 0.11970 0.09731 0.07010 361 0.03800 0.00205 -0.03773 -0.08081 -0.12642 -0.17384 -0.22192 -0.26946 362

-0.31519 -0.35762 -0.39555 -0.42738 -0.45229 -0.46891 -0.47688 -0.47546 363

-0.46448 -0.44372 -0.41347 -0.37372 -0.32588 -0.27047 -0.20974 -0.14533 364

-0.07936 -0.01406 0.04914 0.10832 0.16278 0.21110 0.25382 0.29012 365 0.32190 0.35000 0.37537 0.40077 0.42349 0.44506 0.46111 0.46884 366 0.46807 0.45435 0.43256 0.40306 0.37100 0.34194 0.31528 0.29538 367 0.27916 0.26547 0.25418 0.24230 0.23200 0.22333 0.21599 0.21165 368 0.20712 0.20142 0.19290 0.17840 0.15974 0.13582 0.10881 0.08076 369 0.05162 0.02342 -0.00475 -0.03275 -0.06047 -0.08811 -0.11547 -0.14182 370

-0.16864 -0.19552 -0.22317 -0.25479 -0.28931 -0.32407 -0.35462 -0.38159 371

-0.40356 -0.41752 -0:42399 -0.42130 -0.41097 -0.39351 -0.37026 -0.34264 372

-0.31222 -0.28017 -0.24894 -0.22041 -0.19633 -0.17885 -0.16791 -0.16537 373

-0.16890 -0.17872 -0.19150 -0.20386 -0.21437 -0.22050 -0.22337 -0.22068 374

-0.21418 -0.20464 -0.19381 -0.18353 -0.17489 -0.16960 -0.16776 -0.17060 375

-0.17706 -0.18714 -0.19926 -0.21213 -0.22390 -0.23278 -0.23737 -0.23573 376

-0.22753 -0.21127 -0.18790 -0.15693 -0.12025 -0.07878 -0.03449 0.01091 377 0.05556 0.09784 0.13597 0.16830 0.19424 0.21176 0.22323 0.22791 378 0.22967 0.23131 0.23333 0.24032 0.24832 0.25707 0.26413 0.26497 379 0.26138 0.25056 0.23602 0.22051 0.20198 0.18389 0.15979 0.12722 380 0.08389 0.02361 -0.04792 -0.13227 -0.22113 -0.30863 -0.39009 -0.45763 381

-0.51031 -0.54351 -0.55733 -0.55033 -0.52352 -0.47676 -0.41340 -0.33468 382

-0.24599 -0.15075 -0.05438 0.03809 0.12319 0.19583 0.25579 0.29963 383 0.33054 0.34843 0.35775 0.36199 0.36351 0.36704 0.37143 0.37914 384 0.38777 0.39612 0.40207 0.40332 0.39881 0.38659 0.36637 0.33648 385 0.29804 0.25089 0.19759 0.13971 0.07963 0.01972 -0.03708 -0.08845 386

-0.13060 -0.16067 -0.17592 -0.17237 -0.15163 -0.11087 -0.05627 0.01043 387 0.08261 0.15416 0.22176 0.27914 0.32609 0.35946 0.38006 0.38753 388 0.38302 0.36735 0.34229 0.30935 0.27036 0.22730 0.18135 0.13427 389 0.08667 0.03968 -0.00630 -0.05064 -0.09298 -0.13299 -0.17009 -0.20402 390

-0.23397 -0.25923 -0.27956 -0.29403 -0.30349 -0.30759 -0.30812 -0.30572 391

-0.30075 -0.29420 -0.28621 -0.27729 -0.26726 -0.25631 -0.24365 -0.22865 392

-0.21100 -0.18997 -0.16590 -0.13839 -0.10850 -0.07656 -0.04405 -0.01200 393 0.01803 0.04454 0.06646 0.08217 0.09176 0.09420 0.09069 0.08139 394 0.06809 0.05210 0.03511 0.01897 0.00488 -0.00543 -0.01141 -0.01175 395

-0.00693 0.00370 0.01853 0.03714 0.05745 0.07795 0.09690 0.11238 396 0.12348 0.12858 0.12777 0.12021 0.10707 0.08857 0.06661 0.04246 397 0.01819 -0.00419 -0.02297 -0.03604 -0.04244 -0.04047 -0.03022 -0.01069 398 0.01681 0.05225 0.09336 0.13884 0.18643 0.23385 0.27978 0.32202 399 0.36020 0.39317 0.42066 0.44255 0.45870 0.46882 0.47210 0.46835 400 0.45722 0.43848 0.41291 0.38008 0.34049 0.29467 0.24365 0.18830 401 0.13005 0.07003 0.01008 -0.04837 -0.10333 -0.15291 -0.19575 -0.22976 402

-0;25496 -0.26992 -0.27606 -0.27337 -0.26380 -0.24868 -0.22979 -0.20890 403

-0.18756 -0.16736 -0.14939 -0.13510 -0.12451 -0.11859 -0.11621 -0.11717 404

-0.12006 -0.12360 -0.12685 -0.12831 -0.12769 -0.12402 -0.11745 -0.10762 405

-0.09518 -0.08027 -0.06402 -0.04711 -0.03078 -0.01614 -0.00414 0.00410 406 0.00795 0.00662 -0.00023 -0.01309 -0.03174 -0.05658 -0.08698 -0.12240 407

-0.16065 -0.20059 -0.24005 -0.27699 -0.30968 -0.33589 -0.35464 -0.36410 408

-0.36415 -0.35375 -0.33365 -0.30369 -0.26546 -0.21961 -0.16849 -0.11356 409

-0.05729 -0.00186 0.05100 0.09902 0.14176 0.17771 0.20763 0.23132 410 0.25018 0.26512 0.27754 0.28886 0.30017 0.31290 0.32731 0.34467 411 0.36401 0.38538 0.40645 0.42607 0.44200 0.45195 0.45487 0.44855 412 0.43409 0.41021 0.37854 0.34013 0.29699 0.25056 0.20213 0.15373 413 0.10606 0.06054 0.01752 -0.02218 -0.05865 -0.09144 -0.12126 -0.14816 414

-0.17322 -0.19707 -0.22056 -0.24455 -0.26933 -0.29548 -0.32273 -0.35097 415

-0.37982 -0.40889 -0.43783 -0.46575 -0.49156 -0.51440 -0.53095 -0.53983 416

-0.54177 -0.53807 -0.52830 -0.50865 -0.47950 -0.44106 -0.39456 -0.34051 417

-0.28106 -0.21766 -0.15239 -0.08733 -0.02398 0.03560 0.09082 0.14024 418 0.18404 0.22171 0.25362 0.28004 0.30115 0.31740 0.32883 0.33598 419 0.33873 0.33686 0.33102 0.32138 0.30886 0.29409 0.27861 0.26306 420 0.24813 0.23553 0.22414 0.21413 0.20502 0.19661 0.18766 0.17737 421 0.16480 0.14872 0.12907 0.10501 0.07722 0.04577 0.01160 -0.02453 422

-0.06163 -0.09871 -0.13481 -0.16883 -0.20018 -0.22782 -0.25189 -0.27154 423

-0.28726 -0.29910 -0.30731 -0.31239 -0.31396 -0.31216 -0.30629 -0.29586 424

-0.28080 -0.26039 -0.23544 -0.20577 -0.17286 -0.13744 -0.10109 -0.06510 425

-0.03078 0.00042 0.02770 0.04982 0.06672 0.07766 0.08323 0.08343 426 0.07914 0.07105 0.05990 0.04664 0.03172 0.01596 -0.00043 -0.01692 427

-0.03340 -0.04958 -0.06538 -0.08068 -0.09520 -0.10882 -0.12094 -0.13125 428

-0.13900 -0.14348 -0.14419 -0.14031 -0.13184 -0.11817 -0.09985 -0.07679 429

-0.04987 -0.01950 0.01328 0.04770 0.08267 0.11724 0.15039 0.18113 430 0.20861 0.23193 0.25052 0.26366 0.27108 0.27234 0.26743 0.25619 431

Caic Number: GEO.HBIP.02.06 0.23903

-0.03184

-0.16332

-0.08150

-0.20504

-0.32862

-0.17852

-0.00280

-0.11291

-0.01101 0.27261 0.31470 0.17314

-0.02684

-0.13861

-0.15340

-0.09399 0.01817 0.06802 0.28538

-0.13855

-0.16700

-0.26721

-0.20331 0.13658 0.35577 0.29679 0.16824

-0.21381

-0.03775

-0.00396

-0. 26734

-0.13634 0.33658

-0.00666 0.09882 0.25704

-0.02903 0.20858

-0.03710

-0.20538 0.05364 0.13670

-0.20466 0.11473

-0.13360

-0.04598 0.09860 0.11974 0.07775 0.16833 0.12307

-0.05642

-0.02164

-0.32398 0.02149 0.01008

-0.51509

-0.23839 0.11141

-0.14764 0.03925 0.25994

-0.00024 0.12037 0.15297

-0.15142

-0.20966

-0.14584

-0.12890 0.01663

-0.01766 0.00855 0.21607

-0.06594

-0.15546

-0. 08251

-0.23074

-0.32417

-0.14759

-0.00419

-0.12365

0. 02814 0.29200 0.30485 0.14804

-0.04742

-0.14426

-0.15069

-0.07886 0.03068

0. 06720 0.27940

-0.17564

-0.16026

-0.28199

-0.16856 0.18732 0.33952 0.30746

0. 11340

-0.22070

-0.01254

-0.02062

-0.29702

-0.07832 0.35588

-0.06464 0.18032 0.18529

0. 01121 0.18276

-0.05107

-0.22613

0. 13272 0.06752

-0.18202 0.12016

-0.16712

-0.00364 0.10348

0. 10728
0. 08777 0.17774
0. 09117

-0.04389

-0.06350

-0.31253 D.07623

-0.07633

-0.51111

-0.17934 0.09493

-0.15148 0.08617 0.23492

-0.00506 0.14070

0. 12718

-0.18087

-0.19752

-0.14850

-0.10949 0.02096

-0.02948 0.02529 0.18816

-0.09633

-0.14438

-0. 08819

-0.25540

-0.31495

-0.11692

-0.01135

-0.12879 0.06913 0.30685 0.29236 0.12222

-0.06624

-0.14850

-0.14682

-0.06289 0.04277 0.07414 0.25215

-0.19947

-0.15930

-0.29134

-0.13044 0.23585

0. 31988 0.31511 0.05492 0.15583

-0.12179

-0.13108

-0.09880

-0.27769

-0.30117

-0.08748

-0.02408

-0.12678 0.11013

0. 31740 0.27744 0.09607

-0.08309

-0.15153

-0.14165

-0.04646 0.05616 0.09786 0.19780

-0.21059

-0.16747

-0.29370

-0.09062 0.28075 0.30150 0.31498

-0.00477 I

I

-0.21546 -0.19772 0.00676 0.01843

-0.04236 -0.07018

-0.31560 -0.31735

-0.01639 0.04859 0.35478 0.32731

-0.10620 -0.12489 0.25624 0.31701 0.11051 0.04347 0.05945 0.10984 0.14778 0.10822

-0.06429 -0.08033

-0.23618 -0.23020 0.20164 0.24922

-0.00373 -0.06906

-0.14628 -0.09854 0.11063 0.08549

-0.18934 -0.19614 0.03409 0.06122 0.10936 0.11790 0.09366 0.08140 0.09950 0.11139 0.18470 0.18876 0.05694 0.02218

-0.02646 -0.00624

-0.11319 -0.16746

-0.28771 -0.25151 0.12178 0.15422

-0.16937 -0.26136

-0.49246 -0.46450

-0.11886 -0.05662 0.06509 0.02393

-0.14482 -0.12955 0.13298 0.17867 0.20037 0.15907

-0.00091 0.01115 0.15793 0.17158 0.09479 0.05600

-0.20373 -0.21908

-0.18484 -0.17264

-0.15212 -0.15596

-0.08735 -0.06376 0.02190 0.02093

-0.03915 -0.04462 0.03964 0.04768 0.12026

-0.14198

-0. 11714

-0.11378

-0. 29692

-0. 28319

-0. 06070

-0.04056

-0. 11773 0.14989

0. 323 86 0.26027
0. 06992

-0.09802

-0. 15354

-0. 13512

-0. 03045

0. 06724 0.13068
0. 12915

-0.21143

-0. 18173

-0. 28918

-0. 04860

0. 31850 0.28635 0.30662

-0.06233

-0.17139 0.02385

-0.10315

-0.30529 0.11415 0.28079

-0.12154 0.35836

-0.01202 0.15653 0.06764

-0.09905

-0.20764 0.27552

-0.12599

-0.04578 0.04919

-0.18923 0.08070 0.12583 0.07142 0.12362 0.18824

-0.00957 0.01133

-0.22051

-0.20569 0.16955

-0.34672

-0.42797 0.00101

-0.02186

-0.10613 0.21841 0.11568 0.02918 0.18031 0.01355

-0.22774

-0.16196

-0.15829

-0.04061 0.01726

-0.04530 0.05229

0.08241 0.04361

-0.15604 -0.16429

-0.10408 -0.0929E 3 -0.13279 -0.15493

-0.31191 -0.32253

-0.26132 -0.23622

  • -0.03791 -0.02002

-0.05955 -0.07913

-0.10073 -0.07694 0.18659 0.21983 0.32659 0.32579 0.24103 0.21992 0.04422 0.01926

-0.11100 -0.12207

-0.15484 -0.15525

-0.12739 -0.11806

-0.01667 -0.00382 0.07335 0.07625 0.17764 0.22410 0.05403 -0.02142

-0.20437 -0.19270

-0.20199 -0.22486

-0.27735 -0.25887

-0.00531 0.03988 0.34512 0.36117 0.27986 0.27923 0.28673 0.25684

-0.11473 -0.15924

-0.13882 -0.10348 0.02352 0.01806

-0.14304 -0.18508

-0.27769 -0.23854 0.18116 0.24276 0.21566 0.14134

-0.09329 -0.04528 0.37016 0.35743

-0.04636 -0.06168 0.19185 0.21465 0.03281 0.00244

-0.12332 -0.14987

-0.16302 -0.10318 0.27232 0.24666

-0.16945 -0.19822 0.00731 0.05532 0.00473 -0.04343

-0.16639 -0.13306 0.09054 0.09506 0.13088 0.13265 0.06664 0.06586 0.13543 0.14688 0.18183 0.16922

-0.03484 -0.05240 0.02118 0.02116

-0.26542 -0.30041

-0.15335 -0.09632 0.16229 0.13394

-0.41581 -0.46902

-0.38760 -0.34183 0.05071 0.08827

-0.06540 -0.10409

-0.07747 -0.04298 0.24861 0.26727 0.07555 0.04062 0.05062 0.07429 0.18381 0.18082

-0.03085 -0.07467

-0.23003 -0.22710

-0.15367 -0.14808

-0.15763 -0.15316

-0.02049 -0.00347 0.01164 0.00388

-0.03836 -0.02667 0.05253 0.05181 Rev Number: 0 Sheet Number: 159 of 196 Date: 11/06/02 0.00513 432 9-0.16636 433 8-0.08531 434 l-0.17940 435 1 -0.32802 436

-0.20826 437

-0.00834 438 3-0.09742 439

-0.04640 440 0.24846 441 0.32176 442 0.19720 443

-0.00447 444

-0.13121 445

-0.15482 446

-0.10683 447 0.00734 448 0.07173 449 0.26214 450

-0.08515 451

-0.17910 452

-0.24707 453

-0.23370 454 0.08774 455 0.36312 456 0.28650 457 0.21658 458

-0.19241 459

-0.06924 460 0.00930 461

-0.22840 462

-0.19109 463 0.29669 464 0.06500 465 0.02195 466 0.31613 467

-0.05393 468 0.21880 469

-0.01955 470

-0.17905 471

-0.02719 472 0.19877 473

-0.20964 474 0.09145 475

-0.09085 476

-0.09098 477 0.09732 478 0.12804 479 0.07009 480 0.15811 481 0.14901 482

-0.05882 483 0.00589 484

-0.31930 485

-0.03671 486 0.08076 487

-0.50066 488

-0.29214 489 0.10796 490

-0.13098 491

-0.00369 492 0.27024 493 0.01561 494 0.09777 495 0.17060 496

-0.11527 497

-0.21988 498

-0.14569 499

-0.14325 500 0.00856 501

-0.00654 502

-0.00980 503 0.05302 504

Calc Number: GEO.HBIP.02.06 0.05649 0.11686

-0.07849 0.02108 0.25051 0.27427

-0.20828

-0.31527 0.05938 0.13205 0.19089 0.25185 0.10834

-0.04548

-0.02955 0.21828

-0.11986

-0.42006

-0.34182

-0.24221 0.05695 0.41385 0.38297 0.40590 0.20679

-0.21117

-0.14770

-0.02901 0.16929 0.25277

-0.01611 0.03548

-0.01642 0.08366

-0.16971

-0.33883

-0.39150 0.18369 0.46801 0.16935 0.00515

-0.04579 0.06411

-0.10574

-0.24365

-0.26486

-0.15860

-0.10123

-0.14086

-0.39120

-0.22255 0.33670 0.42156 0.01224

-0.20401

-0.00076

-0.13663

-0.07817 0.43854 0.57999 0.01518

-0.29023

-0.21130

-0.19606 0.13049 0.19636 0.05134

-0.06572

-0.08435

-0.02373 0.12588

-0.15761

-0.26923 0.06584 0.09906

-0.08557 0.04688 0.27087 0.24660

-0.26786

-0.28326 0.09764 0.12729 0.20701 0.24473 0.08812

-0.07131 0.01209 0.21208

-0.17945

-0.42619

-0.32226

-0.23201 0.12164 0.42229 0.38085 0.39396 0.16996

-0.24964

-0.11071

-0.03058 0.22091 0.20273

-0.01271 0.02800

0. 00645
0. 05604

-0.19224

-0.36121

-0.35716 0.25767 0.46721 0.11246 0.00744

-0.04347 0.06723

-0.13662

-0.25035

-0.25704

-0.14689

-0.09994

-0.16151

-0.40833

-0.15999 0.39038 0.38689

-0.04557

-0.19053 0.01145

-0.15976

-0.02819 0.49136 0.54006

-0.05346

-0.29068

-0.21364

-0.15882 0.15237 0.18455 0.03141

-0.06574

-0.09144

-0.00039 0.12307

-0.20607

-0.25414 0.07788 0.07524

-0.08560 0.07411 0.28682 0.20793

-0.31542

-0.24456 0.12692 0.12541 0.22210 0.23378 0.06938

-0.09387 0.05603 0.19376

-0.23483

-0.42631

-0.30386

-0.21646 0.18495 0.42433 0.38188 0.37650 0.12790

-0.27489

-0.07786

-0.02776 0.26763 0.14948

-0.00451 0.01677 0.03355 0.02235

-0.21299

-0.38202

-0.30934 0.32086 0.45682 0.06366 0.00701

-0.03570 0.06246

-0.16404

-0.25629

-0.24655

-0.13664

-0.09998

-0.18737

-0.41536

-0.09201 0.43314 0.34589

-0.09774

-0.17049 0.01395

-0.17607 0.02976 0.53571 0.48670

-0.11395

-0.28480

-0.21970

-0.11477 0.16940 0.16917 0.01188

-0.06417

-0.09613 0.02372 0.11051

-0.24670

-0.23738 0.09340 0.04643

-0.07809 0.10346 0.29730 0.15499

-0.34608

-0.19923 0.14423 0.12824 0.23481 0.21874 0.05352

-0.10966 0.09816 0.16169

-0.28335

-0.42073

-0.28765

-0.19231 0.24324 0.42135 0.38738 0.35340 0.07757

-0.28247

-0.05310

-0.01694 0.30413 0.09970 0.00566 0.00118 0.06217

-0.01355

-0.23283

-0.39999

-0.24555 0.36874 0.43394 0.02954 0.00061

-0.02143 0.04790

-0.18597

-0.26183

-0.23319

-0.12770

-0.10124

-0.21958

-0.40996

-0.01984 0.46190 0.30012

-0.14046

-0.14471 0.00370

-0.18310 0.09569 0.57086 0.41916

-0.16483

-0.27253

-0.22930

-0.06627 0.18361 0.15088

-0.00781

-0.06244

-0.09584 0.04734 0.08574

-0.27435

-0.22049 Sheet I 0.10841 0.12028 0.12725 0.1257 0.01565 -0.01438 -0.04163 -0.0631

-0.06491 -0.04729 -0.02622 -0.0035 0.13367 0.16527 0.19606 0.2248 0.30296 0.30472 0.30074 0.2917 0.09198 0.01824 -0.05936 -0.1364

-0.36297 -0.36615 -0.35776 -0.3408

-0.14949 -0.09522 -0.04070.0.0119 0.15262 0.15251 0.14718 0.1398 0.13491 0.14551 0.15897 0.1744 0.24498 0.25181 0.25532 0.2554 0.20043 0.17864 0.15531 0.1315 0.03779 0.02079 0.00208 -0.0211

-0.11697 -0.11105 -0.09460 -0.0659 0.13707 0.17009 0.19560 0.2122 0.11886 0.06558 0.00603 -0.0566

-0.32525 -0.35978 -0.38702 -0.4070:

-0.41059 -0.39665 -0.37995 -0.3612!

-0.27387 -0.26378 -0.25554 -0.2494,

-0.15981 -0.11654 -0.06531 -0.0062, 0.29532 0.33839 0.37286 0.39751 0.41484 0.40620 0.39710 0.38891 0.39448 0.40252 0.40862 0.4098:

0.32666 0.29901 0.26924 0.23951 0.02224 -0.03921 -0.10090 -0.15961

-0.27597 -0.25490 -0.22421 -0.18713

-0.03551 -0.02672 -0.02378 -0.0257!

0.00224 0.03251 0.07109 0.11849 0.32788 0.33314 0.32260 0.29364 0.05530 0.02239 -0.00098 -0.01284 0.01654 0.02634 0.03352 0.03676

-0.01403 -0.02623 -0.03273 -0.02853 0.08749 0.10308 0.10935 0.10153

-0.05040 -0.08453 -0.11641 -0.14449

-0.25244 -0.27284 -0.29390 -0.31625

-0.41358 -0.42145 -0.42146 -0.41221

-0.17040 -0.08382 0.00710 0.09776 0.40529 0.43178 0.44951 0.46262 0.40002 0.35169 0.29538 0.23230 0.00668 -0.00277 -0.00411 -0.00042

-0.00880 -0.02080 -0.0325S

-0.04117

-0.00353 0.01676 0.03646 0.05286 0.02590 -0.00326 -0.03648 -0.07127

-0.20372 -0.21729 -0.22782 -0.23651

-0.26632 -0.26945 -0.27065 -0.26912

-0.21826 -0.20251 -0.18672 -0.17210

-0.12011 -0.11349 -0.10812 -0.10404

-0.10420 -0.10853 -0.11569 -0.12604

-0.25520 -0.29350 -0.33082 -0.36413

-0.39324 -0.36492 -0.32631 -0.27846 0.05455 0.12998 0.20355 0.27348 0.47789 0.47979 0.47014 0.45023 0.24949 0.19370 0.13494 0.07318

-0.17401 -0.19598 -0.20798 -0.21033

-0.11538 -0.08298 -0.05150 -0.02302

-0.01550 -0.04316 -0.07491 -0.10684

-0.18109 -0.16978 -0.14875 -0.11822 0.16592 0.23843 0.31006 0.37708 0.59581 0.61091 0.61389 0.60388 0.34255 0.25957 0.17455 0.09262

-0.20666 -0.24010 -0.26485 -0.28155

-0.25738 -0.24101 -0.22629 -0.21646

-0.23767 -0.24101 -0.23726 -0.22144

-0.01688 0.02837 0.06949 0.10287 0.19390 0.20126 0.20449 0.20266 0.13079 0.11083 0.09051 0.07088

-0.02590 -0.04152 -0.05402 -0.06156

-0.06166 -0.06423 -0.06878 -0.07632

-0.09109 -0.08031 -0.06508 -0.04582 0.06973 0.09039 0.10737 0.12007 0.05094 0.00500 -0.04699 -0.10285

-0.29150 -0.29653 -0.29301 -0.28339

-0.20289 -0.18376 -0.16455 -0.14451 Rev Number: 0 N4umber: 160 of 196 Date: 11/06/02 0

505 4

506 3

507 0

508 0

509 0

510 6

511 2

512 4

513 4

514 4

515 2

516 9

517 9

518 6

519 8

520 2

521 B

522 1

523 1

524 3

525 5

526 L

527 i6 528 i8 529 3

530

'S 531 1

532 i

533 534 535 3

536 3

537 9

538 S

539 540 541 542 e

543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577

-0.12595

-0.06708 0.18520 0.28613 0.11822 0.17911 0.16730

-0.07771 0.08794 0.00130

-0.16035 0.20475 0.05837

-0.25997

-0.31154

-0.33228

-0.37723

-0.33663 0.03829 0.56337 0.52721 0.05320

-0.27667

-0.34542

-0.22715

-0.08122

-0.08675

-0.06354 0.25172 0.15727

-0.03173 0.02531

-0.09855

-0.11142

-0.00566

-0.06538

-0.10982

-0.04667

-0.01840 0.21487 0.29116.

0.34808 0.51203 0.52052 0.21210 0.03303 0.01598

-0.17082

-0.25448

-0.17879

-0.22279

-0.25429

-0.05868

-0.00466

-0.14255

-0.07047 0.09826

-0.18146

-0.26726

-0.05118

-0. 04986

-0.07306

-0. 18089

-0.27378

-0.05424

-0.05179

-0.18509 0.13806 0.34437 0.28438 0.23451 0.22868 0.15331

-0. 11005

-0. 05035 0.21358 0.27615 0.10802 0.19379 0.13627

-0.08086 0.11308

-0.04096

-0.13679 0.23553 0.00480

-0.27883

-0.31027

-0. 33852

-0.38574

-0.30007 0.09845

0. 60667 0.47089 0.00164

-0.29850

-0.33771

-0.21069

-0.06778

-0.09903

-0.03199 0.27619 0.11987

-0.03330 0.02550

-0.12141

-0.08779

-0.00830

-0.07953

-0.09681

-0.05388 0.00699 0.23810 0.29129 0.36471 0.51973 0.52028 0.15571 0.03691

-0. 00314

-0.19224

-0.24948

-0.17181

-0.23668

-0.23819

-0.03767

-0.01769

-0.15263

-0.03810 0.08632

-0.22292

-0.23815

-0.04212

-0.05238

-0.07685

-0.20578

-0.25994

-0.02930

-0.07622

-0.17054 0.18361 0.35086 0.26538 0.24026 0.22025 0.14268

-0.09728 -0.08969 -0.08485 -0.08309

-0.02752 0.00302 0.23750 0.25659 0.26072 0.23889 0.10434 0.10817 0.20583 0.21451 0.10078 0.06206

-0.07481 -0.05952 0.13010 0.13514

-0.08145 -0.11609

-0.10281 -0.05789 0.25229 0.25109

-0.04746 -0.09498

-0.29335 -0.30351

-0.30961 -0.31027

-0.34464 -0.34980

-0.39344 -0.39981

-0.25822 -0.21341 0.16257 0.23203 0.63744 0.65338 0.40973 0.34683

-0.04750 -0.09485

-0.31590 -0.32927

-0,32848 -0.31757

-0.19381 -0.17569

-0.05809 -0.05323

-0.10978 -0.11726 0.00491 0.04618 0.29052 0.29181 0.08412 0.05292

-0.03040 -0.02282 0.02058 0.00976

-0.14047 -0.15357

-0.06402 -0.04335

-0.01285 -0.01792

-0.09338 -0.10601

-0.08218 -0.06748

-0.06135 -0.06661 0.03561 0.06605 0.25751 0.27223 0.29247 0.29628 0.38362 0.40562 0.52295 0.52072 0.51215 0.48943 0.10769 0.07397 0.04128 0.04534

-0.02529 -0.04915

-0.21141 -0.22772

-0.24203 -0.23277

-0.16803 -0.16893

-0.24903 -0.25851

-0.21828 -0.19418

-0.02038 -0.00672

-0.03391 -0.05276

-0.15816 -0.15853

-0.00485 0.02716 0.06551 0.03595

-0.25831 -0.28492

-0.20542 -0.17182

-0.03733 -0.03611

-0.05474 -0.05735

-0.08227 -0.08995

-0.22956 -0.24998

-0.24028 -0.21475

-0.01049 0.00021

-0.10190 -0.12727

-0.14615 -0.11091 0.22392 0.25694 0.35355 0.35217 0.24827 0.23536 0.24540 0.24830 0.21106 0.20169 0.13187 0.12069

0. 03808 0.27110 0.21372 0.11738 0.21831 0.02344

-0.03695 0.12912

-0.14411

-0.00623 0.23506

-0.13818

-0.31008

-0.31223

-0.35482

-0.40216

-0.16588 0.30341

0. 65506 0.28338

-0.13927

-0.33889

-0.30189

-0.15694

-0.05271

-0.12018

0. 08991 0.28213 0.02595

-0.01267

-0.00591

-0.16015

-0.02602

-0.02438

-0.11605

-0.05453

-0.06857 0.09755 0.28278 0.30220 0.42881 0.51692 0.45483 0.05068 0.04737

-0.07425

-0.24080

-0.22218

-0.17378

-0.26478

-0.16717 0.00285

-0.07288

-0.15318 0.05578

-0.00055

-0.30229

-0.13911

-0.03745

-0.06000

-0.10064

-0.26648

-0.18516 0.00344

-0.15039

-0.06794 0.28406 0.34661 0.22659 0.24905 0.19210 0.10976

0. 07625 0.28196 0.18614 0.13061 0.21625

-0.01199

-0.00810 0.10968

-0.16331 0.05082 0.20382

-0.17595

-0.31315

-0.31571

-0.35932

-0.39783

-0.11817 0.37558 0.64165 0.22222

-0.18038

-0.34561

-0.28343

-0.13689

-0.05672

-0.11653 0.13486 0.26059 0.00398

-0.00077

-0.02602

-0.15806

-0.01451

-0.03207

-0.12172

-0.04594

-0.06453 0.12893 0.28864 0.31059 0.45358 0.51509 0.40323 0.03747 0.04616

-0.09920

-0.24983

-0.21070

-0.18285

-0.26819

-0.13862 0.00788

-0. 09289

-0.14129 0.07833

-0.04301

-0.30837

-0.11005

-0.04011

-0.06309

-0.11572

-0.27728

-0.15201

-0.00136

-0.16971

-0.01838 0.30544 0.33596 0.22369 0.24703 0.18276 0.09983

-0 0

0 0

0 0

-0 0

0

-0 O.

0

-0

-0

-0

-O.

-0.

-O.

0.

0.

O.

-0

-0.

-0.

-0.

-O.

-0.

0.

0.

-0.

0.

-0.

-0.

-0.

-0.

-0.

-0.

-0.

0.

0.

0.

0.

0.

0.

0.

0.

-0.

-0.

-0.

-0.

-0.

-0.

0.

-0.

-0.

0.

-0.

-0.

-0.

-0.

-0.

-0.

-0.

-0.

-0.

-0.

0.

0.

-O.

0.;

0.:

0.:

0.1 Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 161 of 196 Date: 11/06/02

.08100 -0.07616 578

.11513 0.15157 579

.28806 0.28980 580

.15934 0.13637 581

.14648 0.16289 582

.20756 0.19085 583

.04232 -0.06425 584

.02388 0.05718 585

.08065 0.04319 586

.17292 -0.17213 587

.10769 0.16035 588

.16182 0.11225 589

.20866 -0.23672 590

.31392 -0.31308 591

.32034 -0.32605 592

.36428 -0.37042 593

.38651 -0.36529 594

.06837 -0.01669 595

.44496 0.50832 596

.61511 0.57597 597

.16296 0.10684 598

.21750 -0.24943 599

.34890 -0.34882 600

.26374 -0.24465 601

.11711 -0.09813 602

.06425 -0.07479 603

.10634 -0.08835 604

.17819 0.21813 605

.23100 0.19561 606 01289 -0.02488 607 01069 0.01972 608 04905 -0.07391 609 14903 -0.13240 610 00739 -0.00485 611 04130 -O.05273 612 12304 -0.11850 613 04127 -0.04231 614 05519 -0.03932 615 15945 0.18843 616 29143 0.29178 617 32123 0.33351 618 47682 0.49659 619 51405 0.51808 620 34313 0.27737 621 03192 0.03062 622 04109 0.03065 623 12396 -0.14799 624 25519 -0.25650 625 19925 -0.18818 626 19457 -0.20819 627 26865 -0.26440 628 11011 -0.08333 629 00821 0.00390 630 11197 -0.12872 631 12346 -0.09913 632 09390 0.10054 633 08877 -0.13584 634 30433 -0.28972 635 08496 -0.06555 636 04363 -0.04678 637 06634 -0.06944 638 13417 -0.15663 639 28242 -0.28124 640 11790 -0.08461 641 01284 -0.03014 642 18309 -0.18855 643 03433 0.08715 644 32196 0.33510 645 32175 0.30373 646 22449 0.22867 647 24272 0.23638 648 17325 0.16343 649 09078 0.08307 650

Calc Number: GEO.HBIP.02.06 0.07536

-0.07153

-0.22534

-0.17186 0.10497 0.25211 0.14718

-0.07604

-0.08672

-0.06597

-0.04111

-0.05674

-0.03900 0.20867 0.36540 0.25334 0.01798 0.00321

-0.03511

-0.13024

-0.17501

-0.10614 0.17458 0.36303 0.25465

-0.06679

-0.19798

-0.24113

-0.24562

-0.24859

-0.21077

-0. 01135 0.15379 0.28932 0.20576 0.12614 0.15098 0.07441

-0.13700

-0.19300 -

-0.02971 -

0.14554 0.17049 0.00567 -

-0.09811 -

-0.03130 -

-0.03743 -

0.01121

-0.05303 -

-0.04629 -

0.0677 0.18500

-0.02893 -

-0.15905 -

-0.17703 -

-0.13060 -

-0.15838 -

-0.27179 -

-0.22830 -

-0.02196 0.08668

-0.07695 -

0.04964 0.32618 0.22396 0.12525 0.03079

-0.11121 -

0.10388 0.19151

-0.12003 -

-0.21987 -

0.08905 0.06741 0.05743 0.04434 0.02813

-0.09939 -0.12622 -0.14986 -0.17078

-0.23423 -0.24026 -0.24324 -0.24169

-0.13864 -0.10190 -0.06331 -0.02447 0.12968 0.15220 0.17360 0.19332 0.25552 0.25348 0.24459 0.23086 0.12307 0.09727 0.06897 0.03934

-0.09251 -0.10280 -0.10502 -0.10278

-0.08878 -0.09187 -0.09473 -0.09593

-0.05421 -0.04333 -0.03573 -0.03092

-0.04528 -0.04891 -0.05067 -0.05173

-0.06079 -0.06499 -0.06895 -0.07113

-0.01763 0.00829 0.03837 0.07125 0.23983 0.26852 0.29430 0.31667 0.36575 0.36143 0.35241 0.33924 0.22522 0.19525 0.16358 0.13146

-0.00035 -0.01350 -0.02053 -0.02259 0.01062 0.01572 0.01679 0.01403

-0.05144 -0.06750 -0.08173 -0.09455

-0.13693 -0.14306 -0.14863 -0.15400

-0.18010 -0.18335 -0.18391 -0.18039

-0.07337 -0.03736 0.00033 0.03855 0.20284 0.22928 0.25431 0.27819 0.37693 0.38476 0.38427 0.37554 0.21146 0.16653 0.12239 0.07926

-0.09489 -0.11926 -0.13939 -0.15612

-0.20560 -0.21254 -0.21900 -0.22491

-0.24351 -0.24526 -0.24631 -0.24684

-0.24590 -0.24649 -0.24752 -0.24860

-0.24732 -0.24567 -0.24400 -0.24141

-0.19325 -0.17197 -0.14640 -0.11868 0.00965 0.02906 0.04743 0.06573 0.17847 0.20263 0.22516 0.24541 0.28921 0.28495 0.27647 0.26497 0.19195 0.17902 0.16720 0.15649 0.12388 0.12394 0.12693 0.13153 0.15095 0.14821 0.14234 0.13366 0.05329 0.02972 0.00342 -0.02453

-0.15921 -0.17765 -0.19132 -0.20051

-0.18150 -0.16684 -0.14937 -0.12937 -

-0.00144 0.02658 0.05372 0.07889 0.15429 0.16104 0.16706 0.17158 0.16034 0.14604 0.12708 0.10499

-0.01740 -0.03857 -0.05753 -0.07349

-0.09326 -0.08541 -0.07512 -0.06389 -

-0.02884 -0.02835 -0.02942 -0.03150 -

-0.03528 -0.03122 -0.02455 -0.01664 -

0.01069 0.00681 -0.00097 -0.01105 -

-0.06007 -0.06518 -0.06843 -0.06935 -

-0.03374 -0.01977 -0.00523 0.00969 0.08512 0.10356 0.12399 0.14376 0.17624 0.15973 0.13486 0.10462

-0.05529 -0.07801 -0.09647 -0.11195 -

0.16851 -0.17644 -0.18211 -0.18567 -

-0.17172 -0.16587 -0.16004 -0.15408 -

0.12597 -0.12291 -0.12204 -0.12362 -

0.17268 -0.18821 -0.20435 -0.22048 -

0.27805 -0.28104 -0.28020 -0.27599 -

0.20971 -0.18858 -0.16483 -0.13894 -

0.00629 0.03212 0.05448 0.07248 0.07447 0.05721 0.03545 0.01116 -

0.08771 -0.09157 -0.08713 -0.07472 -

0.09307 0.13765 0.18132 0.22225 0.33339 0.33335 0.32641 0.31353 0.19837 0.17460 0.15424 0.13808 0.12885 0.13085 0.12819 0.12066 0.00108 -0.02809 -0.05419 -0.07671 -

0.10400 -0.09021 -0.06972 -0.04333 -

0.14271 0.17754 0.20591 0.22581 0.15664 0.11570 0.07155 0.02643 -

0.14574 -0.16769 -0.18702 -0.20273 -

0.20469 -0.18078 -0.14651 -0.10519 -

0.12987 0.16487 0.19214 0.21326 0.0073

-0. 1880

-0.2340 0.0122 0.2123 0.2130 0.0073

-0.0974:

-0.0928

-0. 03021

-0.0520!

-0.0700 0.1057 0.33531 0.3224:

0.0994'

-0.0197 0.0064,

-0.10531

-0. 15911

-0. 1709' 0.07551 0.30171 0.3565i

0. 0385C

-0.1695C

-0. 2300C

-0.24671

-0.24934

-0.2379C

-0. 08995 0.08558 0.26238 0.25115 0.14659 0.13745 0.12254

-0.05385

-0.20498

-0.10715 0.10076 0.17540 0.08079

-0.08598

-0.05317

-0.03394

-0.00758

-0.02225

-0.06781 0.02376 0.16207 0.07074

-0.12547

-0.18637

-0.14802

-0.12829 0.23596

0. 26840 0.11086 0.08516
0. 01412
0. 05373 0.25818 0.29566 0.12800 0.10571
0. 09406
0. 01125 0.23438
0. 01598 0.21561
0. 05760 0.22851 4 -0.0164 1 -0.2026 6 -0.2203 1

0.0466 7 0.2289 7

0.1923 9 -0.0233!

3 -0.0913 5 -0.0871:

9 -0.0322:

9 -0.05261 5 -0.0650 5 0.1409:

0. 3499!

L 0.3021 7 0.0691(

-0.01361 2-0.00471 6-0. 11472 0-0.1642!

7 -0.15589 0.1109E 0.32384 B0.3296C D 0.00032 D -0.18051 P -0.23445

-0.24636

-0.24978

-0.23218

-0. 06153 0.10657 0.27566 0.23599 0.13812 0.14336 0.10880

-0.08310

-0.20507

-0.08296 0.11950 0.17696 0.05535

-0. 09455

-0. 04354

-0.03614 0.00087

-0.03381

-0.06363 0.03806 0.17638 0.03558

-0.13731

-0.18504

-0.14207

-0.13566

-0.25011

-0.25774

-0.08158 0.09207

-0.03849

-0.02549 0.28831 0.27398 0.12259 0.08539

-0.10598 0.02480 0.23200

-0:05557

-0.22346

-0.00745 0.23936 Rev Number: 0 Sheet Number: 162 of 196 Date: 11/06/02 8 -0.04340 651 2 -0.21513 652 7 -0.19905 653 7

0.07726 654 6

0.24266 655 0

0.17064 656 9 -0.05182 657 6 -0.08828 658 1 -0.07731 659 1 -0.03620 660 0 -0.05427 661 7 -0.05455 662 1 0.17539 663 5 0.35999 664 3 0.27909 665 00.04163 666 6 -0.00543 667 1-0.01904 668 2-0.12298 669 5-0.16979 670 9 -0.13370 671 8 0.14386 672 0.34503 673 4 0.29479 674

-0.03494 675

-0.18989 676

-0.23812 677

-0.24591 678

-0.24939 679

-0.22326 680

-0.03550 681 0.12972 682 0.28468 683 0.22080 684 0.13111 685 0.14803 686 0.09289 687

-0.11113 688

-0.20095 689

-0.05691 690 0.13403 691 0.17554 692 0.03023 693

-0.09838 694

-0.03636 695

-0.03748 696 0.00736 697

-0.04401 698

-0.05617 699 0.05245 700 0.18423 701 0.00220 702

-0.14873 703

-0.18170 704

-0.13602 705

-0.14590 706

-0.26220 707

-0.24439 708

-0.05156 709 0.09244 710

-0.05989 711 0.00968 712 0.31092 713 0.24955 714 0.12271 715 0.05960 716

-0.11178 717 0.06406 718 0.21678 719

-0.08986 720

-0.22538 721 0.04208 722 0.24735 723

Caic Number: GEO.HBEP.02.06 0.25297 0.21268

-0.05182

-0.01048 0.15548 0.16031 0.12121

-0.18201

-0.23036

-0.05210

-0.07349 0.00459 0.07818 0.02625 0.00719 0.08245

-0.08912

-0.18443

-0.24096

-0.22269

-0.07421 0.01710

-0.02036

-0.11280

-0.11449 0.02360

-0.02537

-0.04347 0.18684 0.15404 0.07793 0.05229

-0.20213

-0.25199

-0.01975 0.02717

-0.08457

-0.03190 0.08414 0.11820

-0.04706

-0.17643 0.10040 0.27540 0.19115

-0.07495

-0.13227

-0.13240

-0.07788

-0.11697

-0.17917 0;17010 0.19017 0.09817 0.22320 0.17416

-0.05748

-0.02494

-0.06875

-0.02654

-0.02932

-0.03210 0.03828 0.04522 0.02910 0.03733

-0.06205

-0.15697 0.07404 0.20899

-0.07457

-0.14439 0.01682 0.25781 0.18289

-0.06537 0.01295 0.16132 0.16093 0.09721

-0.21597

-0.20374

-0.04784

-0.07329 0.01927 0.07784 0.01590 0.02150 0.06941

-0.10705

-0.19468

-0.24213

-0.21191

-0.05316 0.01724

-0.02905

-0.12556

-0.09729 0.03083

-0.04112

-0.01760 0.19847 0.13575 0.08564 0.02460

-0.22762

-0.22857 0.00149 0.01356

-0.08689

-0. 01961 0.09830 0.10919

-0.08121

-0.15205 0.12951 0.28433 0.15752

-0.09660

-0.12865

-0.13151

-0.07121

-0.13670

-0.15004 0.20137 0.16858 0.10754 0.23256 0.14748

-0.06911

-0.01853

-0.07652

-0.01688

-0.03679

-0.02248 0.04188 0.04439 0.02802 0.03410

-0.08150

-0.14716 0.11151 0.18759

-0.10373

-0.12803 0.03367 0.26103 0.14821

-0.07239 0.03792 0.16397 0.16147 0.06723

-0.24331

-0.17471

-0.04743

-0.07012 0.03301 0.07523 0.00641 0.03769 0.05134

-0.12254

-0.20480

-0.24240

-0.19843

-0.03416 0.01555

-0.03851

-0.13621

-0.07817 0.03396

-0.05548 0.01297 0.20447 0.11754 0.09375

-0.00693

-0.24908

-0.20060 0.01862

-0.00245

-0.08571

-0.00667 0.11048 0.09710

-0.11437

-0.12045 0.15618 0.28840 0.12158

-0.11388

-0.12561

-0.12865

-0.06708

-0.15682

-0.11235 0.22416 0.14714 0.12084 0.23784 0.11746

-0.07437

-0.01569

-0.08063

-0.00981

-0.04330

-0.01199 0.04423 0.04316 0.02790 0.02815

-0.10053

-0.13066 0.14573 0.15846

-0.12743

-0.10850 0.04872 0.26341 0.26301 0.10925 0.06931

-0.07350 -0.06913 0.06385 0.08886 0.16433 0.16320 0.16168 0.16038 0.03066 -0.01020

-0.26230 -0.27290

-0.14553 -0.11786

-0.04996 -0.05455

-0.06310 -0.05320 0.04530 0.05594 0.07045 0.06383

-0.00182 -0.00765 0.05474 0.07026 0.02926 0.00473

-0.13537 -0.14642

-0.21440 -0.22307

-0.24232 -0.24133

-0.18193 -0.16307

-0.01826 -0.00528 0.01242 0.00799

-0.04862 -0.05968

-0.14340 -0.14684

-0.05819 -0.03822 0.03250 0.02699

-0.06727 -0.07502 0.04724 0.08229 0.20565 0.20216 0.10059 0.08644 0.10002 0.10292

-0.04059 -0.07542

-0.26596 -0.27716

-0.16941 -0.13666 0.03148 0.03979

-0.02003 -0.03768

-0.08119 -0.07411 0.00703 0.02142 0.11967 0.12596 0.08210 0.06359

-0.14477 -0.16980

-0.08353 -0.04382 0.18128 0.20435 0.28680 0.27944 0.08477 0.04810

-0.12631 -0.13442

-0.12451 -0.12467

-0.12302 -0.11553

-0.06621 -0.06887

-0.17625 -0.19217

-0.06676 -0.01685 0.23729 0.24175 0.12803 0.11203 0.13746 0.15591 0.23857 0.23471 0.08427 0.05037

-0.07290 -0.06671

-0.01769 -0.02345

-0.07906 -0.07346

-0.00650 -0.00632

-0.04780 -0.05010

-0.00134 0.00899 0.04557 0.04613 0.04140 0.03924 0.02926 0.03131 0.01887 0.00681

-0.11853 -0.13439

-0.10682 -0.07728 0.17525 0.19863 0.12226 0.08194

-0.14527 -0.15704

-0.08698 -0.06448 0.06203 0.07328 0.25914 0.25030 0.03141 -0.00300

-0.06048 -0.04750 0.11134 0.13064 0.16198 0.16073 0.15697 0.15001

-0.05426 -0.09907

-0.27421 -0.26724

-0.09429 -0.07487

-0.06023 -0.06594

-0.04050 -0.02607 0.06478 0.07153 0.05577 0.04654

-0.01017 -0.00894 0.08190 0.08879

-0.02038 -0.04524

-0.15623 -0.16539

-0.22991 -0.23533

-0.23944 -0.23603

-0.14197 -0.11967 0.00431 0.01103 0.00225 -0.00449

-0.07200 -0.08507

-0.14528 -0.13937

-0.01926 -0.00212 0.01752 0.00508

-0.07732 -0.07343 0.11528 0.14504 0.19504 0.18432 0.07718 0.07231 0.09976 0.09080

-0.109SS -0.14266

-0.28156 -0.27915

-0.10429 -0.07316 0.04348 0.04256

-0.05383 -0.06777

-0.06520 -0.05484 0.03683 0.05258 0.12866 0.12819 0.04118 0.01520

-0.18653 -0.19427

-0.00466 0.03354 0.22606 0.24542 0.26572 0.24624 0.01314 -0.01961

-0.13795 -0.13830

-0.12654 -0.12894

-0.10627 -0.09635

-0.07541 -0.08572

-0.20225 -0.20476 0.03455 0.08478 0.23762 0.22671 0.10088 0.09455 0.17503 0.19349 0.22650 0.21359 0.01721 -0.01312

-0.05703 -0.04570

-0.03329 -0.04502

-0.06357 -0.05149

-0.00932 -0.01464

-0.04940 -0.04615 0.01833 0.02653 0.04632 0.04610 0.03657 0.03384 0.03407 0.03647

-0.00789 -0.02467

-0.14732 -0.15608 Rev Number: 0 Sheet Number. 163 of 196 Date: 11/06/02 0.23462 724

-0.03052 725

-0.03061 726 0.14508 727 0.16030 728 0.13834 729

-0.14222 730

-0.25187 731

-0.06109 732

-0.07064 733

-0.01085 734 0.07602 735 0.03656 736

-0.00278 737 0.08866 738

-0.06819 739

-0.17486 740

-0.23879 741

-0.23052 742

-0.09670 743 0.01520 744

-0.01205 745

-0.09910 746

-0.12872 747 0.01237 748

-0.00961 749

-0.06179 750 0.16867 751 0.17027 752 0.07335 753 0.07446 754

-0.17368 755

-0.26883 756

-0.04489 757 0.03686 758

-0.07793 759

-0.04376 760 0.06870 761 0.12470 762

-0.01481 763

-0.19024 764 0.06827 765 0.26216 766 0.22096 767

-0.04910 768

-0.13591 769

-0.13113 770

-0.08661 771

-0.09991 772

-0.19682 773 0.13037 774 0.21020 775 0.09385 776 0.20975 777 0.19612 778

-0.03813 779 0.03458 780 0.05747 781 0.03874 782

-0.02161 783 0.04012 784 0.03313 785 0.04581 786 0.03120 787 0.03778 788 0.04288 789 0.15950 790

-0.04262 -0.00476 0.03466 0.21466 0.22233 0.22026 0.04005 -0.00158 -0.03991

-0.16270 -0.16241 -0.15591

-0.04254 -0.02127 -0.00149 0.08224 0.08903 0.09348 791 792 793 794 795 796

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 164 of 196 Date: 11/06/02 0.09599 0.06365

-0.15021

-0.29666 0.01811 0.17351

-0.00281 0.10594 0.08957 0.04975 0.12119

-0.04065

-0.11576

-0.00693

-0.10402

-0.16129 0.00475 0.12810 0.04215

-0. 07436

-0.07934 0.03975 0.15908 0.10526

-0.09567

-0.08943

-0.14065

-0.16511 0.08820 0.10011 0.00155 0.20635 0.22142

-0.10841

-0.27641

-0.05543 0.08773 0.12393 0.09883

-0.02020

-0.16856

-0.17401

-0.24742

-0.18433 0.02527 0.07261 0.05491 0.06836

-0.01668

-0.00059 0.05842

-0.08030

-0.10397 0.16858 0.29081 0.30268 0.30742 0.11221

-0.25034

-0.04547 0.00781

-0.00482 0.08498 0.09003 0.22395 0.34391 0.04970

-0.16522

-0.19723

-0.21455

-0.24179

-0.23594

-0.17740 0.09676 0.05089

-0.18612

-0.28359 0.06914 0.14976

-0.00200 0.12229 0.06797 0.06808 0.11053

-0.06274

-0.10796

-0.00276

-0.11980

-0.15382 0.03004 0.12788 0.02380

-0.08083

-0.07091 0.05962 0.16137 0.08439

-0.10990

-0.08308

-0.15675

-0.14111 0.10921 0.08159 0.01266 0.23257 0.18967

-0.14699

-0.26895

-0.02306 0.09665 0.12149 0.09624

-0.05243

-0.16624

-0.18401

-0.24967

-0.15837 0.03961 0.07084 0.05608 0.06380

-0.02561 0.01195 0.05097

-0.09891

-0.08139 0.20132 0.28723 0.31001 0.30343 0.05346

-0.24916

-0.02123 0.00166 0.00439 0.09192 0.09356 0.25082 0.32454 0.01408

-0.17974

-0.19566

-0.21745

-0.24811

-0.22632

-0.17770 0.09601 0.03442

-0.21945

-0.26189 0.11435 0.12147 0.00460 0.13485 0.04775 0.08694 0.09585

-0.08217

-0.09693

-;0.00435

-0.13328

-0.14183 0.05328 0.12402 0.00560

-0.08554

-0.06027 0.07924 0.16075 0.06037

-0.11898

-0.07972

-0.17143

-0.11179 0.12451 0.06188 0.03002 0.25372 0.15261

-0.18177

-0.25423 0.00514 0.10481 0.11818 0.09188

-0.08401

-0.16254

-0.19522

-0.24965

-0.12977

0. 05072 0.06822 0.05819 0.05670

-0.03174 0.02464 0.03949

-0.11450

-0.05353 0.22982 0.28308 0.31605 0.29656

-0.00781

-0.23650

-0.00268

-0.00453 0.01543 0.09651 0.10080 0.27703 0.29664

-0.01863

-0.19081

-0.19502

-0.21994

-0.25365

-0.21632

-0.18059 0.09410 0.01334

-0.24785

-0.23055 0.15056 0.09131 0.01598 0.14217 0.03198 0.10343 0.07770

-0.09766

-0.08256

-0.01328

-0.14406

-0.12416 0.07376 0.11647

-0.01185

-0.08877

-0.04729 0.09840 0.15789 0.03300

-0.12222

-0.08102

-0.18343

-0.07772 0.13373 0.04219 0.05345 0.26814 0.11157

-0.21172

-0.23141 0.02716 0.11216 0.11447 0.08495

-0.11201

-0.15947

-0.20692

-0.24770

-0.09935 0.05925 0.06500 0.06126 0.04676

-0.03423 0.03668 0.02397

-0.12604

-0.02059 0.25304 0.28034 0.31874 0.28589

-0.06837-

-0.21289 0.00930

-0.01006 0.02766 0.09820 0.11310 0.30217 0.26035

-0.04876

-0.19781

-0.19613

-0.22176

-0.25712

-0.20681

-0.18640 0.09091 0.08669

-0.01203 -0.04251

-0.27113 -0.28803

-0.19131 -0.14389 0.17716 0.19215 0.06187 0.03666 0.03115 0.04882 0.14380 0.13821 0.02143 0.01898 0.11698 0.12540 0.05670 0.03327

-0.10938 -0.11687

-0.06641 -0.04872

-0.02714 -0.04525

-0.15237 -0.15894

-0.10257 -0.07731 0.09130 0.10578 0.10582 0.09250

-0.02817 -0.04269

-0.09038 -0.09054

-0.03243 -0.01601 0.11608 0.13149 0.15246 0.14517 0.00429 -0.02455

-0.12089 -0.11531

-0.08630 -0.09607

-0.19155 -0.19457

-0.04142 -0.00491 0.13711 0.13491 0.02435 0.01019 0.08125 0.11216 0.27529 0.27393 0.06780 0.02274

-0.23663 -0.25600

-0.20257 -0.16788 0.04478 0.05836 0.11829 0.12239 0.11065 0.10712 0.07419 0.05788

-0.13575 -0.15236

-0.15744 -0.15787

-0.21836 -0.22836

-0.24282 -0.23465

-0.06895 -0.04059 0.06533 0.06965 0.06167 0.05870 0.06451 0.06759 0.03492 0.02159

-0.03342 -0.02907 0.04717 0.05523 0.00546 -0.01540

-0.13296 -0.13455 0.01572 0.05440 0.27095 0.28299 0.27933 0.28203 0.31945 0.31767 0.26904 0.24326

-0.12490 -0.17323

-0.18214 -0.14693 0.01594 0.01819

-0.01415 -0.01593 0.04046 0.05310 0.09788 0.09541 0.12939 0.14954 0.32381 0.34082 0.21897 0.17530

-0.07635 -0.10232

-0.20170 -0.20259

-0.19845 -0.20211

-0.22380 -0.22671

-0.25846 -0.25642

-0.19800 -0.19028

-0.19464 -0.20516 0.0808E

-0. 07629

-0. 2981X

-0.0917!

0. 1964a 0.01632 0.06791 0.1270C 0.02293 0.1291C 0.00864

-0.12032

-0.03191

-0.06544

-0.16274

-0.05009 0.11684 0.07706

-0.05542

-0.08889 0.00173 0.14422 0.13505

-0.05191

-0.10733

-0.10899

-0.19173 0.03014 0.12764 0.00076 0.14444 0.26449

-0.02248

-0.26932

-0.13044 0.06915 0.12478 0.10391 0.03684

-0.16339

-0.16059

-0.23693

-0.22258

-0.01469 0.07214 0.05634 0.06968 0.00789

-0.02186 0.06021

-0.03740

-0.13048 0.09377 0.29004 0.28692 0.31457 0.20903

-0.21185

-0.11033 0.01680

-0.01526 0.06506 0.09255 0.17264 0.35102 0.13092

-0.12585

-0.20163

-0.20636

-0.23044

-0.25190

-0.18410

-0.21701 0.07352

-0.11293

-0.30138 5-0.03661 0.18938 0.00350

  • 0.08750 D0.10978 0.03416 0.12755

-0.01641

-0.11996 l -0.01743

-0.08515

-0.16389

-0. 02248 0.12434 0.06010

-0.06586

-0.08518 0.02041 0.15325 0.12186

-0. 07580

-0. 09812

-0.12427

-0.18171 0.06134

0. 11565

-0.00205 0.17640 0.24657

-0. 06648

-0.27635

-0.09225 0.07902 0.12513 0.10147 0.00986

-0.16806

-0.16615

-0.24316

-0.20551 0.00705 0.07307 0.05510 0.07007

-0.00512

-0.01208 0.06132

-0.05935

-0.12024 0.13223 0.29204 0.29445 0.31154 0.16427

-0.23734

-0.07617 0.01317

-0.01134 0.07588 0.09031 0.19761 0.35203 0.08922

-0.14702

-0.19956

-0.21056

-0.23586

-0.24475

-0.17966

-0.22965 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 165 of 196 Date: 11/06/02

-0.24157 -0.25175 -0.25844 -0.26010 -0.25541 -0.24247 -0.22163 -0.19152 870

-0.15438 -0.11051 -0.06272 -0.01317 0.03633 0.08307 0.12660 0.16511 871 0.19883 0.22726 0.25052 0.26886 0.28221 0.29090 0.29482 0.29419 872 0.28894 0.27913 0.26509 0.24677 0.22540 0.20136 0.17636 0.15166 873 0.12829 0.10804 0.09043 0.07652 0.06489 0.05507 0.04612 0.03669 874 0.02697 0.01609 0.00484 -0.00653 -0.01748 -0.02719 -0.03555 -0.04192 875

-0.04635 -0.04858 -0.04862 -0.04641 -0.04197 -0.03530 -0.02651 -0.01565 876

-0.00306 0.01119 0.02618 0.04167 0.05598 0.06831 0.07680 0.07986 877 0.07678 0.06576 0.04807 0.02307 -0.00670 -0.03986 -0.07428 -0.10725 878

-0.13811 -0.16451 -0.18664 -0.20367 -0.21526 -0.22151 -0.22122 -0.21407 879

-0.19929 -0.17567 -0.14477 -0.10576 -0.06247 -0.01631 0.02886 0.06939 880 0.10370 0.12809 0.14375 0.14921 0.14702 0.13845 0.12570 0.11136 881 0.09682 0.08438 0.07473 0.06941 0.06840 0.07249 0.08078 0.09323 882 0.10825 0.12482 0.14143 0.15649 0.16912 0.17789 0.18251 0.18227 883 0.17715 0.16693 0.15204 0.13254 0.10948 0.08336 0.05557 0.02729 884

-0.00047 -0.02625 -0.04967 -0.06969 -0.08625 -0.09895 -0.10774 -0.11248 885

-0.11347 -0.11052 -0.10469 -0.09614 -0.08642 -0.07650 -0.06752 -0.06098 886

-0.05692 -0.05637 -0.05856 -0.06337 -0.07009 -0.07777 -0.08621 -0.09459 887

-0.10259 -0.10993 -0.11552 -0.11904 -0.11915 -0.11473 -0.10580 -0.09092 888

-0.07219 -0.04952 -0.02577 -0.00291 0.01755 0.03287 0.04387 0.04919 889 0.05087 0.04983 0.04772 0.04661 0.04727 0.05140 0.05929 0.07180 890 0.08874 0.11052 0.13578 0.16439 0.19361 0.22207 0.24693 0.26551 891 0.27661 0.27744 0.26908 0.25045 0.22374 0.19010 0.15146 0.11016 892 0.06730 0.02495 -0.01606 -0.05445 -0.08925 -0.11953 -0.14439 -0.16288 893

-0.17479 -0.17925 -0.17711 -0.16815 -0.15394 -0.13525 -0.11387 -0.09124 894

-0.06900 -0.04884 -0.03174 -0.01919 -0.01126 -0.00881 -0.01108 -0.01800 895

-0.02836 -0.04124 -0.05547 -0.06972 -0.08323 -0.09475 -0.10409 -0.11048 896

-0.11435 -0.11539 -0.11473 -0.11276 -0.11075 -0.10979 -0.11037 -0.11376 897

-0.11909 -0.12686 -0.13536 -0.14368 -0.15078 -0.15485 -0.15631 -0.15400 898

-0.14894 -0.14146 -0.13186 -0.12111 -0.10853

-0.09436 -0.07829 -0.05958 899

-0.03934 -0.01719 0.00499 0.02619 0.04541 0.06091 0.07331 0.08176 900 0.08753 0.09131 0.09373 0.09611 0.09823 0.10080 0.10355 0.10640 901 0.10955 0.11285 0.11658 0.12095 0.12585 0.13151 0.13738 0.14334 902 0.14870 0.15297 0.15548 0.15570 0.15288 0.14650 0.13614 0.12116 903 0.10225 0.07901 0.05366 0.02690 0.00146 -0.02043 -0.03733 -0.04648 904

-0.04879 -0.04279 -0.03114 -0.01470 0.00362 0.02127 0.03621 0.04565 905 0.04882 0.04377 0.03116 0.01026 -0.01677 -0.04916 -0.08388 -0.11859 906

-0.15085 -0.17744 -0.19760 -0.20881 -0.21180 -0.20574 -0.19199 -0.17131 907

-0.14526 -0.11513 -0.08320 -0.05107 -0.02149 0.00329 0.02143 0.03024 908 0.03018 0.01959 0.00088 -0.02528 -0.05624 -0.08941 -0.12310 -0.15455 909

-0.18273 -0.20591 -0.22299 -0.23291 -0.23492 -0.22794 -0.21235 -0.18745 910

-0.15500 -0.11551 -0.07133 -0.02423 0.02348 0.06957 0.11181 0.14807 911 0.17638 0.19464 0.20222 0.19728 0.18157 0.15459 0.11983 0.07928 912 0.03613 -0.00595 -0.04546 -0.07912 -0.10665 -0.12654 -0.13852 -0.14232 913

-0.13759 -0.12403 -0.10249 -0.07266 -0.03723 0.00291 0.04448 0.08480 914 0.12202 0.15296 0.17792 0.19513 0.20583 0.21038 0.20929 0.20380 915 0.19350 0.17898 0.15994 0.13611 0.10840 0.07662 0.04283 0.00794 916

-0.02589 -0.05667 -0.08328 -0.10356 -0.11789 -0.12505 -0.12664 -0.12293 917

-0.11586 -0.10697 -0.09760 -0.08960 -0.08349 -0.08047 -0.08063 -0.08429 918

-0.09142 -0.10193 -0.11518 -0.13100 -0.14748 -0.16388 -0.17750 -0.18630 919

-0.18857 -0.18150 -0.16590 -0.13987 -0.10655 -0.06654 -0.02328 0.02027 920 0.06239 0.09968 0.13258 0.15928 0.18119 0.19872 0.21251 0.22409 921 0.23257 0.23885 0.24133 0.23934 0.23217 0.21838 0.19903 0.17343 922 0.14387 0.11146 0.07823 0.04645 0.01706 -0.00786 -0.02819 -0.04290 923

-0.05205 -0.05540 -0.05312 -0.04521 -0.03227 -0.01448 0.00706 0.03174 924 0.05840 0.08602 0.11379 0.14064 0.16617 0.18962 0.21081 0.22933 925 0.24503 0.25780 0.26708 0.27290 0.27391 0.26976 0.25888 0.24005 926 0.21302 0.17624 0.13189 0.07976 0.02371 -0.03400 -0.09018 -0.14087 927

-0.18526 -0.22007 -0.24633 -0.26309 -0.27152 -0.27255 -0.26662 -0.25482 928

-0.23761 -0.21545 -0.18961 -0.16060 -0.13023 -0.09968 -0.07044 -0.04413 929

-0.02135 -0.00336 0.00976 0.01753 0.02004 0.01727 0.00959 -0.00278 930

-0.01895 -0.03838 -0.05973 -0.08197 -0.10356 -0.12315 -0.13916 -0.15004 931

-0.15463 -0.15132 -0.14009 -0.11968 -0.09190 -0.05669 -0.01721 0.02472 932 0.06629 0.10436 0.13781 0.16395 0.18318 0.19456 0.19911 0.19741 933 0.19045 0.17930 0.16529 0.14950 0.13374 0.11942 0.10807 0.10153 934 0.10007 0.10520 0.11574 0.13187 0.15179 0.17433 0.19761 0.21992 935 0.23971 0.25521 0.26559 0.26930 0.26664 0.25677 0.24088 0.21933 936 0.19323 0.16396 0.13173 0.09783 0.06209 0.02486 -0.01324 -0.05226 937

-0.09047 -0.12716 -0.16049 -0.18870 -0.21113 -0.22595 -0.23383 -0.23407 938

-0.22794 -0.21599 -0.19931 -0.17906 -0.15608 -0.13148 -0.10594 -0.08038 939

-0.05528 -0.03134 -0.00889 0.01168 0.02989 0.04555 0.05784 0.06641 940 0.07054 0.06951 0.06353 0.05198. 0.03626 0.01667 -0.00489 -0.02694 941

-0.04812 -0.06647 -0.08167 -0.09230 -0.09887 -0.10098 -0.09943 -0.09462 942

Caic Number: GEO.HBIP.02.06

-0.08733

-0.02554

-0.02579

-0.09454

-0.09571

-0.03186

-0.08465

-0.12627

-0.10530 0.14675 0.10047 0.08772 0.30119 0.34859

-0.01532

-0.11867

-0.08862

-0.14359 0.07990 0.27883 0.29191 0.18370 0.14235 0.14894 0.11682

-0.14546

-0.30239

-0.52623

-0.29381 0.23046 0.08362

-0.11093 0.11189 0.18271

-0.05884

-0.32483

-0.34285

-0.25365

-0.22739

-0.07768 0.13849 0.06810 0.01869 0.23163 0.30510

-0.18000

-0.25589

-0.09653

-0.05574 0.02052 0.18824 0.20178 0.15669 0.19488

-0.20049

-0.29941 0.01144 0.15998 0.10357 0.12312 0.07822 0.02995 0.05837

-0.16829

-0.35664

-0.47401

-0.31990

0. 03402 0.40947 0.16654

-0.19684

-0.14044 0.00709

-0.07827 -0.06827

-0.02438 -0.02426

-0.02826 -0.03248

-0.10539 -0.11440

-0.08034 -0.06456

-0.03749 -0.04441

-0.09250 -0.10016

-0.12859 -0.13067

-0.08358 -0.05636 0.16557 0.17647 0.08302 0.06891 0.10336 0.12246 0.33084 0.35599 0.31848 0.28111

-0.05533 -0.08816

-0.10615 -0.09313

-0.10546 -0.12393

-0.11897 -0.08955 0.10317 0.12667 0.29555 0.30788 0.27964 0.26610 0.17179 0.16124 0.14579 0.14916 0.15186 0.15540 0.08640 0.05132

-0.16540 -0.18296

-0.33048 -0.36033

-0.54018 -0.54478

-0.21351 -0.13081 0.25354 0.26391 0.03324 -0.01429

-0.09496 -0.07265 0.13800 0.15998 0.16828 0.14861

-0.09950 -0.13937

-0.34319 -0.35706

-0.32761 -0.31204

-0.24908 -0.24556

-0.22341 -0.21683

-0.04078 -0.00376 0.14300 0.14240 0.05112 0.03532 0.03470 0.05539 0.26227 0.29038 0.26206 0.20762

-0.22212 -0.25431

-0.23244 -0.20688

-0.08738 -0.07985

-0.05500 -0.05314 0.04126 0.06308 0.20267 0.21358 0.19259 0.18297 0.16593 0.17802 0.16434 0.12406

-0.24386 -0.27974

-0.27097 -0.23633 0.04550 0.07539 0.15929 0.15522 0.10064 0.10015 0.12622 0.12783 0.05845 0.03925 0.04575 0.06173 0.03642' 0.01008

-0.19251 -0.21558

-0.37839 -0.39869

-0.47794 -0.47629

-0.27959 -0.23808 0.08926 0.14566 0.42167 0.42111 0.10316 0.04111

-0.20947 -0.21511

-0.11629 -0.09111

-0.00062 -0.01554

-0.05805

-0.02451

-0.03927

-0.12082

-0.05018

-0.05091

-0.10713

-0.13303

-0.02321 0.17793 0.06065 0.14536 0.37433 0.23670

-0. 11191

-0.08147

-0.14238

-0.05785

0. 15240 0.31499 0.25203 0.15220 0.15100 0.16018 0.01337

-0.19941

-0.39110

-0.53750

-0.05077 0.26105

-0.05439

-0.04559 0.17675 0.12347

-0.17730

-0.36613

-0.29827

-0.24201

-0.20634 0.03124 0.13722 0.02164 0.08020 0.31566 0.14264

-0.27645

-0.18155

-0.07262

-0.04867 0.08521 0.21998 0.17332 0.19304 0.07467

-0.30689

-0.19682 0.10059 0.14786 0.10226 0.12806 0.02296 0.07487

-0.01965

-0.23838

-0.41671

-0.46699

-0.19722 0.20222 0.40616

-0.01608

-0.21426

-0.06525

-0.03773

-0. 04835

-0.02501

-0.04797

-0.12397

-0.03817

-0. 05762

-0.11332

-0. 13408

0. 01297 0.17188 0.05715 0.17160 0.38565 0.18765

-0.12749

-0.07269

-0.15773

-0. 02545 0.17877 0.31760 0.23765 0.14521 0.15195 0.16290

-0.02514

-0.21587

-0.42211

-0.51732 0.02473 0.24582

-0.08651

-0.01516 0.18846 0.09371

-0.21306

-0.37049

-0.28578

-0.23889

-0.19138 0.06321 0.12813 0.01116 0.10811 0.33468 0.07246

-0.28889

-0.15754

-0.06662

-0.04155 0.10740 0.22257 0.16474 0.20680 0.01958

-0.32485

-0.15436 0.12122 0.13863 0.10600 0.12556 0.01098 0.08421

-0.05111

-0.26107

-0.43253

-0.45080

-0.15534 0.25656 0.37849

-0.06776

-0.20776

-0.04107

-0.06399

-0.03998 -0.0331

-0.02488 -0.02491

-0.05863 -0.07041

-0.12292 -0.11801

-0.03083 -0.0271S

-0.06393 -0.07036

!-0.11788 -0.12154

-0.13336 -0.1291(

0.05072 0.08723 0.15863 0.14092 0.05900 0.06521 0.20204 0.23446 0.38881 0.38377 0.13522 0.08234

-0.13452 -0.13463

-0.06860 -0.06948

-0.16655 -0.16835 0.00408 0.03194 0.20624 0.23289 0.31598 0.31073 0.22351 0.20964 0.14099 0.13903 0.15091 0.14963 0.16151 0.15464

-0.06087 -0.09377

-0.23393 -0.25390

-0.45230 -0.48050

-0.48112 -0.43150 0.09143 0.14893 0.21759 0.17987

-0.10750 -0.11859 0.01728 0.05017 0.19483 0.19591 0.05938 0.02187

-0.24602 -0.27589

-0.36984 -0.36483

-0.27574 -0.26701

-0.23587 -0.23294

-0.17022 -0.14413 0.09026 0.11226 0.11595 0.10133 0.00509 0.00384 0.13785 0.16898 0.34569 0.34597 0.00175 -0.06660

-0.29226 -0.28736

-0.13748 -0.12039

-0.06189 -0.05836

-0.03038 -0.01620 0.12953 0.15067 0.22119 0.21676 0.15759 0.15329 0.21672 0.21998

-0.03798 -0.09580

-0.33283 -0.33123

-0.11086 -0.06771 0.13739 0.14909 0.12829 0.11819 0.11037 0.11514 0.11953 0.10989 0.00652 0.00801 0.08730 0.08436

-0.08257 -0.11338

-0.28494 -0.30893

-0.44580 -0.45667

-0.42604 -0.39531

-0.11216 -0.06683 0.30650 0.35003 0.33776 0.28736

-0.11178 -0.14827

-0.19651 -0.18103

-0.01982 -0.00356

-0.09215 -0.11959 Rev Number: 0 Sheet Number: 166 of 196 Date: 11/06/02 3-0.02850 943 1-0.02490 944 1-0.08261 945 1-0.10835 946 7-0.02805 947 6-0.07741 948 4 -0.12411 949 6-0.11992 950 30.11975 951 0.12078 952 1 0.07467 953 60.26834 954 0.37034 955 0.03152 956 3 -0.12868 957 3 -0.07670 958

-0.15983 959 0.05656 960 0.25734 961 0.30252 962 0.19631 963 0.13996 964 0.14882 965 0.13914 966

-0.12149 967

-0.27692 968

-0.50595 969

-0.36737 970 0.19550 971 0.13368 972

-0.11921 973 0.08212 974 0.19196 975

-0.01791 976

-0.30228 977

-0.35537 978

-0.25956 979

-0.23055 980

-0.11253 981 0.12822 982 0.08509 983 0.00856 984 0.20042 985 0.33218 986

-0.12720 987

-0.27448 988

-0.10715 989

-0.05680 990 0.00105 991 0.17062 992 0.21015 993 0.15298 994 0.21252 995

-0.15034 996

-0.31963 997

-0.02673 998 0.15661 999 0.10989 1000 0.11941 1001 0.09537 1002 0.01688 1003 0.07441 1004

-0.14167 1005

-0.33310 1006

-0.46654 1007

-0.35929 1008

-0.01774 1009 0.38490 1010 0.22912 1011

-0.17646 1012

-0.16216 1013 0.00546 1014

-0.14306 1015

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 167 of 196 Date: 11/06/02

-0.16160 -0.17245 -0.17634 -0.17215 -0.16158 -0.14530 -0.12510 -0.10265 1016

-0.07917 -0.05640 -0.03491 -0.01580 0.00077 0.01429 0.02508 0.03300 1017 0.03891 0.04320 0.04656 0.05000 0.05304 0.05654 0.05888 0.05967 1018 0.05770 0.05138 0.04147 0.02680 0.00973 -0.00891 -0.02717 -0.04261 1019

-0.05532 -0.06323 -0.06811 -0.06986 -0.07005 -0.07028 -0.07048 -0.07214 1020

-0.07377 -0.07534 -0.07526 -0.07204 -0.06522 -0.05318 -0.03684 -0.01565 1021 0.00873 0.03550 0.06302 0.08980 0.11458 0.13585 0.15295 0.16464 1022 0.17133 0.17226 0.16909 0.16232 0.15354 0.14466 0.13565 0.12844 1023 0.12156 0.11503 0.10842 0.10012 0.09238 0.08468 0.08016 0.08118 1024 0.08792 0.10366 0.12462 0.15120 0.17905 0.20436 0.22630 0.24068 1025 0.25039 0.25469 0.25673 0.25937 0.26306 0.27091 0.28099 0.29388 1026 0.30733 0.31963 0.32948 0.33479 0.33498 0.32874 0.31582 0.29560 1027 0.26844 0.23416 0.19421 0.14907 0.10113 0.05198 0.00398 -0.04040 1028

-0.07987 -0.11197 -0.13701 -0.15359 -0.16326 -0.16621 -0.16423 -0.15877 1029

-0.15078 -0.14206 -0.13227 -0.12237 -0.11162 -0.09965 -0.08652 -0.07130 1030

-0.05558 -0.03917 -0.02451 -0.01301 -0.00620 -0.00642 -0.01312 -0.02779 1031

-0.04826 -0.07386 -0.10262 -0.13221 -0.16195 -0.18971 -0.21537 -0.23815 1032

-0.25685 -0.27136 -0.27929 -0.27942 -0.27037 -0.24976 -0.21926 -0.17744 1033

-0.12864 -0.07452 -0.01934 0.03258 0.07948 0.11713 0.14611 0.16472 1034 0.17392 0.17437 0.16631 0.15083 0.12811 0.09853 0.06339 0.02302 1035

-0.02019 -0.06488 -0.10893 -0.15001 -0.18744 -0.21919 -0.24600 -0.26720 1036

-0.28393 -0.29684 -0.30684 -0.31500 -0.32209 -0.32893 -0.33641 -0.34516 1037

-0.35579 -0.36899 -0.38443 -0.40254 -0.42162 -0.44123 -0.45873 -0.47227 1038

-0.47973 -0.47835 -0.46774 -0.44562 -0.41352 -0.37096 -0.32015 -0.26256 1039

-0.19999 -0.13457 -0.06752 -0.00055 0.06517 0.12847 0.18814 0.24307 1040 0.29277 0.33612 0.37369 0.40511 0.43130 0.45291 0.47009 0.48383 1041 0.49333 0.49878 0.49944 0.49448 0.48428 0.46848 0.44862 0.42460 1042 0.39800 0.37040 0.34224 0.31519 0.28850 0.26268 0.23703 0.21088 1043 0.18459 0.15756 0.13088 0.10499 0.08090 0.05977 0.04214 0.02905 1044 0.02077 0.01796 0.02059 0.02909 0.04258 0.06111 0.08297 0.10732 1045 0.13225 0.15611 0.17775 0.19535 0.20888 0.21729 0.22119 0.22070 1046 0.21646 0.20925 0.19929 0.18744 0.17370 0.15843 0.14204 0.12452 1047 0.10707 0.09015 0.07490 0.06257 0.05304 0.04757 0.04448 0.04379 1048 0.04395 0.04332 0.04117 0.03570 0.02803 0.01783 0.00639 -0.00512 1049

-0.01680 -0.02743 -0.03779 -0.04772 -0.05744 -0.06754 -0.07721 -0.08644 1050

-0.09388 -0.09885 -0.10080 -0.09846 -0.09220 -0.08136 -0.06682 -0.04883 1051

-0.02829 -0.00596 0.01743 0.04105 0.06443 0.08690 0.10825 0.12805 1052 0.14614 0.16241 0.17647 0.18828 0.19733 0.20336 0.20617 0.20531 1053 0.20137 0.19415 0.18488 0.17419 0.16299 0.15262 0.14292 0.13493 1054 0.12761 0.12092 0.11411 0.10619 0.09753 0.08747 0.07707 0.06674 1055 0.05724 0.04968 0.04406 0.04124 0.04074 0.04269 0.04638 0.05153 1056 0.05742 0.06347 0.06920 0.07387 0.07775 0.08031 0.08242 0.08440 1057 0.08666 0.09019 0.09419 0.09917 0.10355 0.10660 0.10719 0.10386 1058 0.09659 0.08443 0.06805 0.04757 0.02398 -0.00198 -0.02881 -0.05548 1059

-0.07989 -0.10046 -0.11547 -0.12274 -0.12230 -0.11240 -0.09505 -0.07025 1060

-0.04081 -0.00868 0.02400 0.05451 0.08202 0.10444 0.12206 0.13407 1061 0.14140 0.14440 0.14413 0.14169 0.13766 0.13326 0.12816 0.12308 1062 0.11712 0.11003 0.10121 0.08980 0.07611 0.05959 0.04127 0.02148 1063 0.00131 -0.01816 -0.03635 -0.05212 -0.06546 -0.07572 -0.08325 -0.08798 1064

-0.09049 -0.09103 -0.09043 -0.08918 -0.08815 -0.08810 -0.08938 -0.09282 1065

-0.09776 -0.10447 -0.11147 -0.11798 -0.12266 -0.12393 -0.12153 -0.11408 1066

-0.10240 -0.08621 -0.06670 -0.04465 -0.02123 0.00247 0.02516 0.04578 1067 0.06309 0.07588 0.08378 0.08559 0.08239 0.07386 0.06196 0.04786 1068 0.03290 0.01912 0.00646 -0.00369 -0.01215 -0.01895 -0.02458 -0.02983 1069

-0.03460 -0.03934 -0.04399 -0.04843 -0.05311 -0.05792 -0.06345 -0.07006 1070

-0.07770 -0.08683 -0.09659 -0.10683 -0.11658 -0.12493 -0.13156 -0.13548 1071

-0.13710 -0.13604 -0.13304 -0.12855 -0.12312 -0.11726 -0.11167 -0.10683 1072

-0.10357 -0.10246 -0.10408 -0.10920 -0.11735 -0.12906 -0.14265 -0.15757 1073

-0.17193 -0.18396 -0.19280 -0.19649 -0.19555 -0.18909 -0.17837 -0.16382 1074

-0.14669 -0.12812 -0.10888 -0.09018 -0.07228 -0.05601 -0.04121 -0.02814 1075

-0.01677 -0.00679 0.00100 0.00684 0.00933 0.00776 0.00156 -0.01065 1076

-0.02763 -0.04989 -0.07534 -0.10261 -0.13077 -0.15761 -0.18389 -0.20858 1077

-0.23244 -0.25612 -0.27860 -0.30047 -0.31939 -0.33432 -0.34352 -0.34464 1078

-0.33804 -0.32196 -0.29856 -0.26797 -0.23288 -0.19521 -0.15682 -0.12029 1079

-0.08581 -0.05528 -0.02750 -0.00269 0.02053 0.04346 0.06635 0.09075 1080 0.11555 0.14113 0.16610 0.18941 0.21065 0.22847 0.24337 0.25497 1081 0.26361 0.26985 0.27327 0.27425 0.27217 0.26670 0.25800 0.24557 1082 0.23067 0.21355 0.19583 0.17882 0.16344 0.15130 0.14243 0.13784 1083 0.13698 0.14002 0.14613 0.15489 0.16528 0.17656 0.18768 0.19766 1084 0.20585 0.21124 0.21388 0.21319 0.20961 0.20327 0.19443 0.18360 1085 0.17074 0.15619 0.13988 0.12185 0.10226 0.08116 0.05879 0.03538 1086 0.01117 -0.01354 -0.03844 -0.06324 -0.08744 -0.11061 -0.13222 -0.15167 1087

-0.16862 -0.18253 -0.19332 -0.20068 -0.20466 -0.20512 -0.20243 -0.19651 1088

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 168 of 196 Date: 11/06/02

-0.15204 -0.15346 -0.15957 1089

-0.18852

-0.16840

-0.21240

-0.21854

-0.24876

-0.14718

-0.05662 0.04777 0.14286 0.09467

' 0.06258 0.14439 0.13368 0.03659 0.06901

0. 07298 0.03037

-0.03001

-0.11194

-0.19373

-0.25057

-0.27497

-0.01386 0.19810 0.12205 0.09836 0.23849 0.30820 0.18336 0.13486 0.21076 0.19656

-0.05436

-0.20265

-0.05054 0.11124 0.03306

-0.03400

-0.00832 0.03869 0.05553 0.11755 0.13355 0.07973

-0.01988

-0.17208

-0.27113

-0.33021

-0.32584

-0.26459

-0.12558

-0.01845 0.05798 0.08479 0.07387 0.09222 0.04942 0.03125 0.03220

-0.02036

-0.04724 0.06413 0.11205 0.14654 0.14677

-0.03530

-0.10997

-0.12222

-0.11847

-0.12709

-0.01874 0.05191 0.06489

-0.17871

-0.17931

-0.21092

-0.22135

-0.24791

-0.12899

-0. 04741 0.06107 0.14916 0.08199 0.07143 0.14953 0.12177 0.03342 0.07452 0.06853 0.02563

-0.03823

-0.12735

-0.19962

-0.26065

-0.25536 0.02442 0.20123 0.10842 0.10912 0.25979 0.29855 0.16469 0.14194 0.21896 0.17582

-0.08841

-0.19811

-0.01893 0.10958 0.02093

-0.03624

-0.00083 0.04074 0.06101 0.12548 0.12827 0.07074

-0.03652

-0.18953

-0.28000

-0.33299

-0.32437

-0.24754

-0.11001

-0.00814 0.06744 0.07941 0.07934 0.08838 0.04546 0.03065 0.03030

-0.02953

-0.03853 0.07624 0.11369 0.15392 0.13026

-0.05396

-0.11336

-0.11863

-0.12359

-0.11961

-0.00370 0.05289 0.07158

-0.16897

-0.19059

-0.20953

-0.22465

-0.24373

-0.11264

-0.03696 0.07388 0.15205 0.07086 0.08210 0.15290 0.10819 0.03316 0.07866 0.06345 0.02041

-0.04630

-0.14231

-0.20566

-0.27072

-0.23014 0.06102 0.19909 0.09696 0.12228 0.27907 0.28603 0.14847 0.15059 0.22543 0.15072

-0.11956

-0.18882 0.01185 0.10390 0.00958

-0.03682 0.00663 0.04216 0.06743 0.13223 0.12218 0.06082

-0.05415

-0.20552

-0.28870

-0.33440

-0.32208

-0.22955

-0.09507 0.00165 0.07597 0.07382 0.08491 0.08352 0.04210 0.03040 0.02702

-0.03795

-0.02718 0.08644 0.11563 0.16061 0.11025

-0.06961

-0.11654

-0.11479

-0.12861

-0.10991 0.00994 0.05304 0.07897

-0.1604C

-0.20010

-0.20936

-0.22859

-0.23489

-0. 09937

-0.02456 0.08626 0.15013 0.06231 0.09416 0.15494 0.09338 0.03586 0.08097 0.05773 0.01406

-0. 05389

-0.15523

-0.21219

-0.28086

-0.19994 0.09534 0.19216 0.08873 0.13746 0.29496 0.27159 0.13758 0.16030 0.22989 0.12156

-0.14647

-0.17520 0.04025 0.09523

-0.00071

-0.03550 0.01380 0.04315 0.07470 0.13728 0.11585 0.04977

-0.07290

-0.21951

-0.29726

-0 33421

-0.31835

-0.21139

-0.08064 0.01100 0.08312 0.06916 0.08964 0.07792 0.03937 0.03069 0.02196

-0.04514

-0.01323 0.09451 0.11841 0.16613 0.08711

-0.08170

-0.11992

-0.11139

-0.13249

-0.09779 0.02163 0.05269 0.08645 I -0.15416 I -0.20788

-0.20997

-0.23292

-0.22243

-0. 08831

-0.01098 0.09832 0.14445 0.05639 0.10656 0.15507 0.07848 0.04070 0.08175 0.05180 0.00684

-0.06214

-0.16655

-0.21914

-0.28898

-0.16594 0.12617 0.18148 0.08368 0.15464 0.30706 0.25560 0.13100 0.17069 0.23144 0.08922

-0.16880

-0.15736 0.06517 0.08423

-0.00991

-0.03260

0. 02045 0.04415 0.08266 0.14054 0.10916 0.03771

-0.09239

-0.23198

-0.30545

-0.33310

-0.31278

-0.19321

-0.06686 0.02017 0.08838 0.06579 0.09336 0.07186 0.03714 0.03123 0.01547

-0.05063 0.00223 0.10072 0.12206 0.16949 0.06206

-0.09105 -

-0.12277

-0.10901 -

-0.13522 -

-0.08389 -

0.03143 0.05258 0.09395

-0.21211

-0.21147

-0.23796

-0.20593

-0.07947 0.0036E 0.11071 0.13464 0.05341 0.1182C 0.15343 0.06466 0.04728 0.08118 0.04596

-0. 00188

-0.07204

-0.17516

-0.22610

-0.29369

-0.12959 0.15247 0.16803 0.08247 0.17388 0.31414 0.23888 0.12773 0.18121 0.22939 0.05443

-0.18543

-0.13535 0.08486 0.07201

-0.01794

-0.02804 0.02642 0.04568 0.09119 0.14154 0.10241 0.02467

-0.11267

-0.24293

-0.31313

-0.33134

-0.30439

-0.17554

-0.05369 0.02942 0.09099 0.06489 0.09541 0.06569 0.03521 0.03204 0.00753

-0.05396 0.01849 0.10517 0.12689 0.16979 0.03617

-0.09783

-0.12462

-0.10883

-0.13616

-0.06823 0.03932 0.05352 0.10087

-0. 2141;

-0.21355 6-0.24264 3-0.18715

-0.0718C 0.01873 I

0.1224(

0.12233 0.05342 0.1288C 0.1495C 0.0525C 0.05467 0.07934 0.04026

-0.01117

-0.08335

-0.18227

-0.23368

-0.29390

-0.09146 0.17368 0.15291 0.08459 0.19449 0.31670 0.22199 0.12736 0.19162 0.22326 0.01823

-0.19673

-0.10993 0.09944 0.05896

-0.02469

-0.02229 0.03152 0.04786 0.09998 0.14063 0.09532 0.01066

-0.13301

-0.25281

-0.31997

-0.32925

-0.29367

-0.15832

-0.04122 0.03873 0.09131 0.06589 0.09593 0.05969 0.03364 0.03265

-0.00137

-0.05477 0.03477 0.10828 0.13264 0.16646 0.01053

-0.10285

-0.12539

-0.11031

-0.13525

-0.05175 0.04530 0.05558 0.10752 2 -0.21384

-0.21584 1 -0.24664 9-0.16716 0-0.06436 30.03342 00.13361 30.10867 0.05662 0.13744 D0.14280 0.04317 0.06210 0.07663 0.03528

-0.02064

-0.09715

-0.18830

-0.24178

-0.28743

-0.05267 0.18877 0.13727 0.09002 0.21651 0.31447 0.20315 0.12991 0.20159 0.21225

-0.01843

-0.20230

-0.08110 0.10793 0.04591

-0.03009

-0.01560 0.03558 0.05120 0.10896 0.13781 0.08785

-0.00412

-0.15297

-0.26217

-0.32569

-0.32752

-0.28009

-0.14166

-0.02949 0.04844 0.08888 0.06922 0.09480 0.05427 0.03228 0.03285

-0.01079

-0.05250 0.05008 0.11043 0.13938 0.15868

-0.01344

-0.10676

-0.12435

-0.11385

-0.13227

-0.03503

0. 04942 0.05959 0.11393 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157 1158 1159 1160 1161

Caic Number: GEO.HBIP.02.06 0.12007 0.13817 0.03474

-0.05634

-0.08986

-0.16698

-0.26352

-0.26293

-0.10105

-0.05096

-0.04202 0.04216 0.10132 0.06967 0.12512 0.14155 0.05163 0.00029

-0.07378

-0.06807 0.03087

-0.01177

-0.04329 0.08655 0.12348 0.07181 0.03274

-0.01573

-0.00641

-0.01976

-0.05192

-0.06015

-0.09988

-0.03033 0.03812 0.09459 0.12369 0.05791 0.03199 0.04366 0.04490 0.04638.

0.05018 0.01895

-0.03760

-0.06850

-0.09847

-0.07973

-0.07064

-0.14068

-0:21186

-0.08401 0.05245

-0.03008

-0.05156 0.01463 0.04599 0.12312 0.22331 0.22780 0.19644

-0.00055

-0.06896

0. 09806 0.13323 0.02661 0.03154 0.00877 0.04412 0.08713

-0.01024

-0.02183 0.00431 0.12631 0.13206 0.13734 0.13116 0.12183 0.11033 0.01916 0.00427 -0.00954

-0.06067 -0.06403 -0.06665

-0.09796 -0.10683 -0.11587

-0.17953 -0.19263 -0.20618

-0.27141 -0.27777 -0.28276

-0.24653 -0.22697 -0.20454

-0.08806 -0.07771 -0.06956

-0.05057 -0.05073 -0.05127

-0.03567 0.05421 0.10242 0.06577 0.13712 0.13364 0.04090

-0.00607

-0.08096

-0.05732 0.03573

-0.02271

-0.03366 0.10134 0.11707 0.06814 0.02537

-0.01796

-0.00388

-0.02573

-0.05266

-0.06375

-0.10077

-0.01490 0.04142 0.10271 0.11914 0.05094 0.03312 0.04390 0.04505 0.04654 0.04908 0.01372

-0.04411

-0.07324

-0.09808

-0.07577

-0.07511

-0.15329

-0.21100

-0.05525 0.05008

-0.04061

-0.04637 0.02177 0.04961 0.14236 0.22327 0.23096 0.17636

-0.01998

-0.05868 0.11750 0.12146 0.02012 0.03164 0.00773 0.05417 0.08051

-0.01820

-0.02092 0.00962

-0.02777 -0.01834 0.06531 0.07493 0.10185 0.09942 0.06463 0.06772 0.14693 0.15308 0.12434 0.11381 0.03157 0.02434

-0.01363 -0.02275

-0.08619 -0.08896

-0.04499 -0.03109 0.03717 0.03471

-0.03269 -0.04103

-0.02098 -0.00525 0.11351 0.12249 0.10968 0.10196 0.06466 0.06097 0.01787 0.01062

-0.01903 -0.01885

-0.00222 -0.00187

-0.03169 -0.03708

-0.05308 -0.05338

-0.06824 -0.07367

-0.09905 -0.09398

-0.00068 0.01113 0.04549 0.05143 0.10992 0.11602 0.11272 0.10442 0.04507 0.04035 0.03475 0.03678 0.04394 0.04403 0.04518 0.04537 0.04678 0.04727 0.04702 0.04364 0.00808 0.00170

-0.04963 -0.05353

-0.07839 -0.08370

-0.09684 -0.09507

-0.07207 -0.06889

-0.08095 -0.08798

-0.16571 -0.17733

-0.20618 -0.19657

-0.02774 -0.00342 0.04406 0.03489

-0.04906 -0.05466

-0.03991 -0.03205 0.02764 0.03193 0.05428 0.06011 0.16163 0.17969 0.22208 0.22106 0.23349 0.23489 0.15304 0.12703

-0.03673 -0.05087

-0.04383 -0.02412 0.13310 0.14381 0.10785 0.09304 0.01649 0.01631 0.03020 0.02707 0.00812 0.01012 0.06407 0.07326 0.07095 0.05843

-0.02360 -0.02602

-0.01978 -0.01800 0.01425 0.01752 0.14147 0.09706

-0.02211

-0. 06929

-0.12536

-0. 21960

-0.28547

-0.18105

-0. 06339

-0.05161

-0.00768 0.08316 0.09540 0.07416 0.15619 0.10229 0.01842

-0.03283

-0.08941

-0.01670 0.02917

-0.04729 0.01243 0.12840 0.09429 0.05686 0.00374

-0.01765

-0.00283

-0.0419

-0.05379

-0.07960

-0.08600

0. 02075 0.05857 0.12078 0.09502 0.03672 0.03886
0. 04409 0.04554 0.04787
0. 03943

-0. 00528

-0.05663

-0.08875

-0.09275

-0.06655

-0.09627

-0.18793

-0.18242 0.01733 0.02338

-0.05795

-0.02331 0.03521 0.06776 0.19563 0.22036 0.23420

0. 09969

-0.06190

-0.00124 0.15000 0.07779 0.01825 0.02301 0.01377 0.08106 0.04425

-0.02654

-0.01550 0.01972 0.14397 0.08242

-0.03317

-0.07271

-0.1,3484

-0.23221

-0.28554

-0.15802

-0.05845

-0.05116 0.00414 0.08981 0.08948 0.08460 0.15599 0.08968 0.01380

-0.04365

-0.08746

-0.00227 0.02093

-0.05100 0.03147 0.13113 0.08740 0.05191

-0.00245

-0.01542

-0.00537

-0.04566

-0.05447

-0.08584

-0.07478 0.02742 0.06712 0.12427 0.08516 0.03407 0.04066 0.04429 0.04580 0.04881 0.03459

-0.01326

-0.05913

-0.09283

-0.09006

-0.06550

-0.10586

-0.19702

-0.16291 0.03317 0.01014

-0.05893

-0.01357 0.03793 0.07780 0.20769 0.22093 0.23060 0.07246

-0.06989 0.02403 0.15149 0.06268 0.02187 0.01871 0.01922 0.08681 0.02912

-0.02580

-0.01161 0.02065 0.14452 0.06683

-0.0426!

-0. 0770C

-0.1448!

-0.24402

-0.28223

-0.13621

-0. 0549C

-0.04970 0.01658

0. 09498 0.08284 0.09721 0.15312 0.07676 0.00964

-0.05450

-0.08319 0.01105 0.01080

-0. 05180 0.05079 0.13101 0.08120 0.04626

-0.00788

-0.01263

-0.00915

-0.04862

-0.05566

-0.09169

-0.06139 0.03222 0.07632 0.12602 0.07526 0.03242 0.04216 0.04450 0.04602 0.04961 0.02933

-0.02151

-0.06160

-0.09601

-0.08699

-0.06574

-0.11654

-0.20428

-0.13957

0. 04438

-0.00377

-0.05796

-0.00370 0.04031 0.09020 0.21651 0.22235 0.22351 0.04595

-0.07403 0.04997 0.14887 0.04864 0.02597 0.01449

0. 02618 0.09003 0.01425

-0.02432

-0.00697

0. 02069 Rev Number: 0 Sheet Number. 169 of 196 Date: 11/06/02 0.14255 1162 0.05080 1163 5-0.05027 1164

-0.08288 1165

-0.15555 1166

-0.25436 1167

-0.27456 1168

-0.11734 1169 1-0.05242 1170 I -0.04661 1171 0.02946 1172 0.09891 1173 0.07575 1174 0.11123 1175 0.14829 1176 0.06386 1177 0.00527 1178

-0.06469 1179

-0.07669 1180 0.02229 1181

-0.00029 1182

-0.04921 1183 0.06938 1184 0.12827 1185 0.07616 1186 0.03978 1187

-0.01232 1188

-0.00945 1189

-0.01410 1190

-0.05061 1191

-0.05750 1192

-0.09659 1193

-0.04614 1194 0.03545 1195 0.08557 1196 0.12586 1197 0.06619 1198 0.03179 1199 0.04310 1200 0.04471 1201 0.04619 1202 0.05021 1203 0.02425 1204

-0.02980 1205

-0.06478 1206

-0.09777 1207

-0.08345 1208

-0.06748 1209

-0.12831 1210

-0.20948 1211

-0.11259 1212 0.05067 1213

-0.01742 1214

-0.05552 1215 0.00587 1216 0.04297 1217 0.10575 1218 0.22127 1219 0.22484 1220 0.21199 1221 0.02167 1222

-0.07380 1223 0.07501 1224 0.14260 1225 0.03644 1226 0.02928 1227 0.01116 1228 0.03470 1229 0.09016 1230 0.00102 1231

-0.02311 1232

-0.00140 1233 0.02019 1234

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 170 of 196 Date: 11/06/02 0.01911 0.01791 0.01618 0.01401 0.01109 0.00715 0.00238 -0.00344 1235

-0.00966 -0.01604 -0.02188 -0.02649 -0.02965 -0.03057 -0.02976 -0.02691 1236

-0.02300 -0.01845 -0.01409 -0.01085 -0.00888 -0.00894 -0.01059 -0.01392 1237

-0.01839 -0.02349 -0.02892 -0.03408 -0.03887 -0.04290 -0.04611 -0.04833 1238

-0.04960 -0.04980 -0.04925 -0.04796 -0.04640 -0.04483 -0.04359 -0.04307 1239

-0.04317 -0.04411 -0.04545 -0.04700 -0.04838 -0.04906 -0.04906 -0.04789 1240

-0.04599 -0.04328 -0.04031 -0.03741 -0.03493 -0.03333 -0.03265 -0.03314 1241

-0.03462 -0.03706 -0.04019 -0.04378 -0.04751 -0.05106 -0.05415 -0.05637 1242

-0.05772 -0.05782 -0.05710 -0.05548 -0.05363 -0.05192 -0.05080 -0.05091 1243

-0.05210 -0.05477 -0.05835 -0.06263 -0.06706 -0.07098 -0.07417 -0.07595 1244

-0.07647 -0.07537 -0.07303 -0.06950 -0.06519 -0.06041 -0.05542 -0.05060 1245

-0.04597 -0.04173 -0.03781 -0.03414 -0.03082 -0.02770 -0.02501 -0.02280 1246

-0.02109 -0.02007 -0.01938 -0.01899 -0.01842 -0.01726 -0.01530 -0.01199 1247

-0.00760 -0.00187 0.00471 0.01197 0.01943 0.02672 0.03341 0.03912 1248 0.04354 0.04630 0.04741 0.04661 0.04422 0.04034 0.03534 0.02965 1249 0.02348 0.01731 0.01112 0.00518 -0.00041 -0.00556 -0.01004 -0.01365 1250

-0.01631 -0.01777 -0.01824 -0.01753 -0.01599 -0.01377 -0.01102 -0.00796 1251

-0.00455 -0.00081 0.00328 0.00781 0.01270 0.01800 0.02359 0.02946 1252 0.03534 0.04124 0.04666 0.05147 0.05502 0.05688 0.05679 0.05416 1253 0.04940 0.04229 0.03368 0.02413 0.01408- 0.00442 -0.00498 -0.01358 1254

-0.02163 -0.02918 -0.03614 -0.04271 -0.04857 -0.05357 -0.05767 -0.06049 1255

-0.06241 -0.06332 -0.06358 -0.06350 -0.06297 -0.06226 -0.06092 -0.05875 1256

-0.05555 -0.05078 -0.04486 -0.03754 -0.02945 -0.02094 -0.01233 -0.00419 1257 0.00360 0.01081 0.01757 0.02400 0.03007 0.03604 0.04165 0.04689 1258 0.05162 0.05570 0.05913 0.06190 0.06393 0.06529 0.06576 0.06535 1259 0.06386 0.06116 0.05732 0.05225 0.04615 0.03913 0.03145 0.02335 1260 0.01508 0.00696 -0.00085 -0.00804 -0.01457 -0.02013 -0.02468 -0.02813 1261

-0.03039 -0.03141 -0.03100 -0.02900 -0.02534 -0.01973 -0.01255 -0.00367 1262 0.00621 0.01677 0.02736 0.03735 0.04646 0.05410 0.06034 0.06496 1263 0.06815 0.06992 0.07050 0.07019 0.06909 0.06752 0.06524 0.06245 1264 0.05863 0.05363 0.04709 0.03853 0.02818 0.01570 0.00181 -0.01319 1265

-0.02868 -0.04386 -0.05863 -0.07228 -0.08502 -0.09664 -0.10719 -0.11678 1266

-0.12519 -0.13237 -0.13813 -0.14220 -0.14458 -0.14500 -0.14364 -0.14039 1267

-0.13545 -0.12889 -0.12103 -0.11194 -0.10220 -0.09209 -0.08219 -0.07302 1268

-0.06480 -0.05806 -0.05250 -0.04825 -0.04488 -0.04199 -0.03952 -0.03696 1269

-0.03458 -0.03226 -0.03011 -0.02835 -0.02667 -0.02513 -0.02330 -0.02082 1270

-0.01766 -0.01337 -0.00843 -0.00279 0.00302 0.00857 0.01369 0.01795 1271 0.02135 0.02382 0.02520 0.02557 0.02468 0.02242 0.01896 0.01411 1272 0.00867 0.00289 -0.00231 -0.00604 -0.00802 -0.00727 -0.00433 0.00114 1273 0.00837 0.01689 0.02629 0.03590 0.04559 0.05503 0.06384 0.07197 1274 0.07866 0.08359 0.08625 0.08595 0.08298 0.07691 0.06860 0.05842 1275 0.04708 0.03554 0.02383 0.01274 0.00194 -0.00844 -0.01844 -0.02828 1276

-0.03756 -0.04626 -0.05392 -0.06009 -0.06467 -0.06718 -0.06791 -0.06669 1277

-0.06399 -0.06000 -0.05517 -0.04984 -0.04443 -0.03928 -0.03467 -0.03092 1278

-0.02799 -0.02606 -0.02483 -0.02415 -0.02374 -0.02318 -0.02252 -0.02137 1279

-0.02005 -0.01852 -0.01701 -0.01576 -0.01466 -0.01387 -0.01304 -0.01200 1280

-0.01056 -0.00832 -0.00548 -0.00178 0.00231 0.00667 0.01092 0.01468 1281 0.01785 0.02015 0.02166 0.02237 0.02235 0.02176 0.02058 0.01895 1282 0.01684 0.01431 0.01146 0.00835 0.00518 0.00215 -0.00058 -O.D0274 1283

-0.00429 -0.00499 -0.00488 -0.00383 -0.00194 0.00087 0.00438 0.00857 1284 0.01310 0.01781 0.02236 0.02647 0.02998 0.03266 0.03447 0.03539 1285 0.03529 0.03427 0.03205 0.02860 0.02386 0.01765 0.01041 0.00218 1286

-0.00628 -0.01443 -0.02175 -0.02741 -0.03144 -0.03328 -0.03331 -0.03151 1287

-0.02822 -0.02374 -0.01830 -0.01215 -0.00564 0.00108 0.00741 0.01308 1288 0.01758 0.02045 0.02162 0.02073 0.01814 0.01392 0.00860 0.00264 1289

-0.00346 -0.00909 -0.01385 -0.01717 -0.01881 -0.01829 -0.01572 -0.01079 1290

-0.00407 0.00438 0.01369 0.02337 0.03260 0.04059 0.04694 0.05091 1291 0.05261 0.05171 0.04870 0.04376 0.03747 0.03042 0.02302 0.01597 1292 0.00945 0.00397 -0.00048 -0.00367 -0.00572 -0.00660 -0.00656 -0.00564 1293

-0.00420 -0.00239 -0.00051 0.00120 0.00269 0.00376 0.00465 0.00541 1294 0.00635 0.00779 0.00980 0.01278 0.01647 0.02105 0.02610 0.03148 1295 0.03689 0.04200 0.04677 0.05094 0.05467 0.05794 0.06083 0.06354 1296 0.06587 0.06798 0.06940 0.07000 0.06936 0.06709 0.06318 0.05729 1297 0.04990 0.04108 0.03150 0.02171 0.01205 0.00326 -0.00479 -0.01170 1298

-0.01772 -0.02291 -0.02731 -0.03111 -0.03415 -0.03639 -0.03779 -0.03813 1299

-0.03767 -0.03630 -0.03443 -0.03225 -0.02992 -0.02772 -0.02554 -0.02342 1300

-0.02128 -0.01893 -0.01653 -0.01393 -0.01142 -0.00910 -0.00708 -0.00555 1301

-0.00445 -0.00379 -0.00352 -0.00350 -0.00379 -0.00429 -0.00503 -0.00600 1302

-0.00712 -0.00832 -0.00946 -0.01036 -0.01100 -0.01116 -0.01093 -0.01022 1303

-0.00915 -0.00773 -0.00604 -0.00413 -0.00210 0.00004 0.00210 0.00405 1304 0.00573 0.00704 0.00790 0.00825 0.00806 0.00733 0.00607 0.00434 1305 0.00223 -0.00016 -0.00274 -0.00530 -0.00784 -0.01015 -0.01223 -0.01400 1306

-0.01530 -0.01606 -0.01604 -0.01500 -0.01292 -0.00943 -0.00502 0.00046 1307

Caic Number: GEO.HBIP.02.06 0.00622 0.02186 0.00628

-0.00337

-0.03179

-0.06681

-0.08029

-0. 04646

-0.00473

-0.01780

-0.04270

-0.03999 0.01298 0.04906 0.04430 0.04823 0.04165 0.03519 0.02701 0.02631

-0.01215

-0.01978 0.02143 0.03774 0.03209 0.03273 0.00718 0.00180 0.01478 0.02096 0.03157 0.02698 0.00868

-0.01363

-0. 00898 0.00462 0.00869 0.01538 0.02490 0.02672 0.03955 0.04206 0.01553

-0.02528

-0.03833

-0.04713

-0.02789

-0.02806

-0.03929

-0.03745

-0.00978

-0.00168

-0.00931

-0. 00187

-0.00560

-0.01917

-0.01613

-0.01796

-0.02832

-0.02539

-0. 01814

-0.02429

-0.01132 0.00401

-0.01103

-0.01416

-0.01777

-0.02380

-0.01217

-0.00568

-0.00516

-0.01052

-0.00933 0.01188 0.01695 0.02007 0.01804 0.00472 0.00335

-0.00558 -0.00826

-0.03634 -0.04094

-0.07036 -0.07356

-0.07846 -0.07576

-0.04088 -0.03529

-0.00190 -0.00032

-0.02268 -0.02733

-0.04408 -0.04523

-0.03552 -0.03012 0.02012 0.02673 0.04976 0.04979 0.04388 0.04382 0.04826 0.04791 0.04055 0.03954 0.03394 0.03247 0.02815 0.02946 0.02290 0.01880

-0.01675 -0.02062

-0.01570 -0.01087 0.02521 0.02835 0.03790 0.03763 0.03217 0.03254 0.03090 0.02846 0.00414 0.00165 0.00361 0.00556 0.01576 0.01661 0.02206 0.02332 0.03178 0.03163 0.02555 0.02384 0.00569 0.00257

-0.01433 -0.01444

-0.00782 -0.00653 0.00599 0.00703 0.00903 0.00950 0.01661 0.01786 0.02555 0.02594 0.02788 0.02936 0.04052 0.04125 0.04122 0.03981 0.00922 0.00279

-0.02750 -0.02928

-0.04036 -0.04243

-0.04542 -0.04316

-0.02677 -0.02615

-0.02906 -0.03028

-0.03995 -0.04032

-0.03583 -0.03368

-0.00601 -0.00292

-0.00315 -0.00471

-0.00882 -0.00805

-0.00129 -0.00099

-0.00739 -0.00934

-0.01975 -0.01998

-0.01541 -0.01490

-0.01944 -0.02104

-0.02883 -0.02911

-0.02417 -0.02295

-0.01931 -0.01883

-0.02404 -0.02334

-0.00849 -0.00567 0.00312 0.00160

-0.01245 -0.01355

-0.01398 -0.01395

-0.01869 -0.01966

-0.02348 -0.02276

-0.01048 -0.00904

-0.00548 -0.00531

-0.00564 -0.00628

-0.01094 -0.01123

-0.00868 -0.00817 0.02075 0.01609 0.00233

-0.01141

-0.04553

-0.07630

-0.07210

-0.02966

-0.00030

-0.03128

-0.04619

-0.02383 0.03268 0.04933 0.04430 0.04722 0.03871 0.03072 0.03070 0.01422

-0.02342

-0.00540 0.03090 0.03684 0.03321 0.02546

-0.00007 0.00749 0.01740 0.02491 0.03120 0.02177

-0.00073

-0.01394

-0.00490 0.00770 0.01017 0.01914 0.02601 0.03118 0.04184 0.03775

-0.00343

-0.03073

-0.04443

-0.04039

-0.02592

-0.03180

-0.04036

-0.03074

-0.00078

-0.00616

-0.00703

-0.00095

-0.01135

-0.01981

-0.01462

-0.02262

-0.02911

-0. 02175

-0.01975

-0.02212

-0.00282

-0.00038

-0.01427

-0.01416

-0.02063

-0.02153

-0.00792

-0.00509

-0.00700

-0.01133

-0. 00786 0.02338 0.01409 0.00142

-0.01498

-0.05008

-0.07853

-0.06776

-0.02412

-0.00164

-0.03470

-0.04668

-0.01693 0.03782 0.04848 0.04504 0.04626 0.03795 0.02903 0.03155

0. 00921

-0.02515 0.00036 0.03295 0.03578 0.03387 0.02203

-0. 00109 0.00933 0.01810 0.02655 0.03053 0.01944

-0.00398

-0.01310

-0.00313

0. 00808 0.01098 0.02039 0.02594 0.03312
0. 04223 0.03492

-0.00928

-0.03206

-0.04618

-0.03743

-0.02603

-0.03345

-0.04017

-0.02725 0.00050

-0.00745

-0.00590

-0.00123

-0.01334

-0.01936

-0.01465

-0.02415

-0.02887

-0.02067

-0.02087

-0.02050

-0.00027

-0.00266

-0.01470

-0.01459

-0.02157

-0.01997

-0.00707

-0.00491

-0.00780

-0.01127

-0.00781 0.02447 0.01207 0.00059

-0.01884

-0.05452

-0.08014

-0.06284

-0.01858

-0.00442

-0.03734

-0.04647

-0.00960 0.04202 0.04739 0.04603 0.04519 0.03737 0.02765 0.03156 0.00389

-0.02557 0.00618 0.03470 0.03456 0.03432 0.01831

-0.00127 0.01097 0.01875 0.02823 0.02985 0.01695

-0.00711

-0.01213

-0. 00110 0.00829 0.01195 0.02169 0.02582 0.03503 0.04253 0.03123

-0.01439

-0.03339

-0.04743

-0.03450

-0.02627

-0.03516

-0.03984

-0.02308 0.00088

-0.00844

-0.00473

-0.00183

-0.01518

-0.01866

-0.01499

-0.02548

-0.02831

-0.01968

-0.02207

-0.01857 0.00185,

-0.00496

-0.01478

-0.01520

-0.02245

-0.01810

-0.00649

-0.00476

-0.00856

-0.01098

-0.00808 0.02443 0.01008

-0.00039

-0.02300

-0.05884

-0. 08105

-0.05753

-0.01341

-0.00824

-0.03949

-0.04544

-0.00206 0.04529 0.04623 0.04700 0.04400 0.03676 0.02669 0.03078

-0. 00156

-0.02482 0.01180 0.03603 0.03339 0.03439 0.01446

-0.00082 0.01242 0.01941 0.02972 0.02901 0.01427

-0.00990

-0.01105 0.00093 0.0083S 0.01302 0.02288 0.02579 0.03681 0.04261 0.02674

-0.01883

-0.03483

-0.04811

-0.03181

-0.02674

-0.03681

-0.03929

-0.01865 0.00053

-0.00912

-0.00363

-0.00278

-0.01683

-0.01783

-0.01567

-0.02665

-0.02754

-0.01891

-0.02318

-0.01636 0.00337

-0.00724

-0.01469

-0.01599

-0.02318

-0.01610

-0.00611

-0.00474

-0.00931

-0.01056

-0.00864 Rev Number: 0 Sheet Number: 171 of 196 Date: 11/06/02 0.02348 1308 30.00812 1309

-0.00169 1310 I -0.02731 1311

-0.06294 1312

-0.08110 1313

-0.05206 1314

-0.00866 1315

-0.01282 1316

-0.04124 1317

-0.04323 1318 0.00555 1319 0.04761 1320 0.04516 1321 0.04776 1322 0.04282 1323 0.03608 1324 0.02659 1325 0.02898 1326

-0.00700 1327

-0.02283 1328 0.01690 1329 0.03710 1330 0.03259 1331 0.03386 1332 0.01071 1333 0.00028 1334 0.01369 1335 0.02013 1336 0.03083 1337 0.02810 1338 0.01155 1339

-0.01206 1340

-0.01004 1341 0.00288 1342 0.00852 1343 0.01417 1344 0.02399 1345 0.02610 1346 0.03831 1347 0.04251 1348 0.02142 1349

-0.02239 1350

-0.03649 1351

-0.04797 1352

-0.02961 1353

-0.02729 1354

-0.03818 1355

-0.03855 1356

-0.01410 1357

-0.00036 1358

-0.00939 1359

-0.00265 1360

-0.00404 1361

-0.01815 1362

-0.01695 1363

-0.01668 1364

-0.02759 1365

-0.02653 1366

-0.01836 1367

-0.02391 1368

-0.01393 1369 0.00407 1370

-0.00925 1371

-0.01442 1372

-O.01683 1373

-0.02365 1374

-0.01409 1375

-0.00584 1376

-0.00486 1377

-0.00996 1378

-0.00996 1379

-0.00947 1380

Caic Number: GEO.HB[P.02.06

-0.01049 -0.01161

-0.01670 -0.01651

-0.01107 -0.01054

-0.01162 -0.01209

-0.01423 -0.01380

-0.00831 -0.00780

-0.00504 -0.00483

-0.00498 -0.00512

-0.00792 -0.00831

-0.00948 -0.00923

-0.00546 -0.00486

-0.00046 0.00004 0.00119 0.00139 0.00459 0.00519 0.00987 0.01036 0.00902 0.00833 0.00577 0.00611 0.01069 0.01126 0.01091 0.01044 0.00932 0.00982 0.01323 0.01372 0.01363 0.00997

-0.00233 -0.00185

-0.00069 -0.00033 0.00118 0.00146 0.00539 0.00612 0.01098 0.01164 0.01572 0.01628 0.01967 0.02013 0.02337 0.02386 0.02733 0.02783 0.03088 0.03121 0.03239 0.03243 0.03175 0.03155 0.02956 0.02921 0.02653. 0.02614 0.02305 0.02258 0.01899 0.01846 0.01472 0.01419 0.01050 0.00999 0.00648 0.00600 0.00286 0.00245

-0.00023 -0.00057

-0.00275 -0.00302

-0.00471 -0.00491

-0.00613 -0.00627

-0.00709 -0.00717

-0.00764 -0.00768

-0.00788 -0.00789

-0.00788 -0.00786

-0.00769 -0.00765

-0.00739 -0.00734

-0.00700 -0.00695

-0.00658 -0.00652

-0.00614 -0.00608

-0.00570 -0.00564

-0.00526 -0.00521

-0.00485 -0.00479

-0.00445 -0.00440

-0.00408 -0.00403

-0.00372 -0.00367

-0.00338 -0.00334

-0.00307 -0.00303

-0.00277 -0.00273

-0.00250 -0.00246

-0.00224 -0.00220

-0.00198 -0.00194

-0.00172 -0.00169

-0.00148 -0.00145

-0.00127 -0.00125

-0.00111 -0.00109

-0.00098 -0.00097

-0.00089 -0.00088

-0.01278 -0.01386 -0.01485

-0.01610 -0.01541 -0.01459

-0.01023 -0.01012 -0.01022

-0.01260 -0.01311 -0.01359

-0.01320 -0.01237 -0.01147

-0.00738 -0.00695 -0.00657

-0.00471 -0.00468 -0.00471

-0.00534 -0.00565 -0.00605

-0.00867 -0.00896 -0.00922

-0.00890 -0.00842 -0.00788

-0.00428 -0.00365 -0.00302 0.00043 0.00071 0.00088 0.00165 0.00203 0.00246 0.00579 0.00646 0.00714 0.01069 0.01085 0.01081 0.00761 0.00696 0.00638 0.00658 0.00719 0.00787 0.01169 0.01198 0.01208 0.00996 0.00958 0.00925 0.01041 0.01114 0.01183 0.01406 0.01497 0.01510 0.00584 0.00236 -0.00063

-0.00136 -0.00121 -0.00118 0.00002 0.00031 0.00054 0.00180 0.00225 0.00276 0.00684 0.00757 0.00826 0.01226 0.01287 0.01346 0.01679 0.01731 0.01780 0.02058 0.02105 0.02150 0.02434 0.02484 0.02533 0.02831 0.02880 0.02926 0.03148 0.03173 0.03192 0.03243 0.03241 0.03234 0.03131 0.03108 0.03080 0.02883 0.02847 0.02808 0.02572 0.02531 0.02488 0.02208 0.02159 0.02108 0.01792 0.01739 0.01685 0.01365 0.01313 0.01260 0.00947 0.00896 0.00845 0.00553 0.00507 0.00460 0.00204 0.00164 0.00125

-0.00091 -0.00123 -0.00156

-0.00329 -0.00354 -0.00380

-0.00511 -0.00529 -0.00548

-0.00641 -0.00653 -0.00666

-0.00726 -0.00733 -0.00741

-0.00773 -0.00776 -0.00780

-0.00790 -0.00790 -0.00791

-0.00784 -0.00782 -0.00780

-0.00762 -0.00758 -0.00755

-0.00730 -0.00724 -0.00720

-0.00690 -0.00684 -0.00680

-0.00647 -0.00641 -0.00636

-0.00603 -0.00597 -0.00592

-0.00559 -0.00553 -0.00548

-0.00516 -0.00510 -0.00505

-0.00475 -0.00469 -0.00465

-0.00436 -0.00430 -0.00426

-0.00398 -0.00394 -0.00390

-0.00363 -0.00359 -0.00355

-0.00330 -0.00326 -0.00322

-0.00299 -0.00295 -0.00292

-0.00270 -0.00266 -0.00263

-0.00243 -0.00239 -0.00237

-0.00217 -0.00214 -0.00211

-0.00191 -0.00188 -0.00185

-0.00166 -0.00162 -0.00160

-0.00143 -0.00140 -0.00137

-0.00123 -0.00121 -0.00119

-0.00107 -0.00105 -0.00104

-0.00096 -0.00094 -0.00093

-0.00087 -0.00086 -0.00085

-0.01565

-0.01364

-0.01043

-0. 01400

-0.01055

-0.00613

-0.00475

-0.00650

-0.00941

-0.00728

-0.00234 0.00098 0.00296 0.00788 0.01059 0.00597 0.00860 0.01200 0.00905 0.01235

0. 01538

-0. 00219

-0.00115 0.00071 0.00335 0.00897 0.01405 0.01829 0.02197 0.02584 0.02972 0.03209 0.03225 0.03053 0.02770 0.02445 0.02057 0.01632 0.01208 0.00796 0.00416 0.00087

-0.00186

-0. 00403

-0.00565

-0.00677

-0.00747

-0.00782

-0.00790

-0. 00777

-0.00751

-0.00715

-0.00674

-0.00630

-0.00586

-0.00542

-0.00500

-0.00459

-0.00421

-0.00385

-0.00350

-0.00318

-0.00288

-0.00260

-0.00233

-0.00207

-0.00181

-0.00156

-0.00134

-0.00116

-0.00102

-0.00092

-0.00085

-0.01625

-0.01269

-0.01078

-0. 01428

-0. 00968

-0.00574

-0.00483

-0. 00700

-0.00954

-0.00667

-0.00169 0.00102 0.00348 0.00858 0.01019 0.00569 0.00933 0.01176 0.00897 0.01277 0.01824

-0. 00298

-0.00115 0.00083 0.00399 0.00965 0.01461 0.01875

0. 02243
0. 02633 0.03013 0.03221 0.03211 0.03022 0.02730 0.02399 0.02004 0.01578 0.01154 0.00745 0.00372 0.00049

-0.00217

-0.00427

-0.00582

-0.00689

-0.00754

-0.00785

-0.00790 -

-0.00775 -

-0.00747 -

-0.00710 -

-0.00669 -

-0.00625 -

-0.00581 -

-0.00537 -

-0.00495 -

-0.00455 -

-0.00417 -

-0.00381 -

-0.00347 -

-0.00315 -

-0.00285 -

-0.00256 -

-0.00230 -

-0.00204 -

-0.00178 -

0.00154 -

0.00132 -

-0.00115 -

0.00101 -

0.00091 -

0.00084 -

Rev Number: 0 Sheet Number: 172 of 196 Date: 11/06/02

-0.01659 1381

-0.01181 1382

-0.01116 1383

-0.01435 1384

-0.00894 1385

-0.00535 1386

-0.00487 1387

-0.00746 1388

-0.00955 1389

-0.00606 1390

-0.00104 1391 0.00110 1392 0.00403 1393 0.00927 1394 0.00966 1395 0.00565 1396 0.01005 1397 0.01138 1398 0.00907 1399 0.01302 1400 0.01668 1401

-0.00287 1402

-0.00094 1403 0.00100 1404 0.00468 1405 0.01034 1406 0.01518 1407 0.01922 1408 0.02291 1409 0.02684 1410 0.03053 1411 0.03233 1412 0.03195 1413 0.02991 1414 0.02693 1415 0.02353 1416 0.01952 1417 0.01526 1418 0.01103 1419 0.00697 1420 0.00329 1421 0.00014 1422

-0.00246 1423

-0.00449 1424

-0.00597 1425

-0.00698 1426

-0.00759 1427

-0.00786 1428

-0.00788 1429

-0.00772 1430

-0.00742 1431

-0.00705 1432

-0.00663 1433

-0.00619 1434

-0.00575 1435

-0.00531 1436

-0.00489 1437

-0.00450 1438

-0.00412 1439

-0.00376 1440

-0.00342 1441

-0.00310 1442

-0.00281 1443

-0.00253 1444

-0.00227 1445 0.00201 1446 0.00175 1447 0.00151 1448 0.00130 1449 0.00112 1450 0.00099 1451 0.00090 1452 0.00083 1453

Calc Number: GEO.HBIP.02.06

-0.00083 -0.00082

-0.00078 -0.00078

-0.00075 -0.00075

-0.00073 -0.00073

-0.00071 -0.00071

-0.00070 -0.00069

-0.00068 -0.00068

-0.00067 -0.00066

-0.00065 -0.00065

-0.00063 -0.00063

-0.00061 -0.00061

-0.00060 -0.00059

-0.00058 -0.00057

-0.00056 -0.00055

-0.00054 -0.00053

-0.00052 -0.00051

-0.00049 -0.00049

-0.00047 -0.00047

-0.00045 -0.00045

-0.00043 -0.00042

-0.00040 -0.00040

-0.00038 -0.00038

-0.00081

-0.00077

-0.00075

-0.00073

-0.00071

-0.00069

-0.00068

-0.00066

-0.00064

-0.00063

-0.00061

-0. 00059

-0.00057

-0.00055

-0.00053

-0.00051

-0.00049

-0.00047

-0.00044

-0.00042

-0.00040

-0.00037

-0.00081

-0.00077

-0.00074

-0.00072

-0.00071

-0.00069

-0.00067

-0.00066

-0.00064

-0.00062

-0.00061

-0.00059

-0.00057

-0. 00055

-0.00053

-0. 00051

-0.00049

-0. 00046

-0.00044

-0.00042

-0.00039

-0.00042

-0.00080

-0.00077

-0.00074

-0.00072

-0.00070

-0.00069

-0.00067

-0.00066

-0.00064

-0.00062

-0.00060

-0.00059

-0.00057

-0.00055

-0. 00053

-0. 00051

-0.00048

-0.00046

-0.00044

-0.00041

-0.00039

-0.00042

-0.00080

-0.00076

-0.00074

-0.00072

-0. 00070

-0.00069

-0.00067

-0.00065

-0.00064

-0.00062

-0.00060

-0. O0058

-0.00056

-0.00054

-0.00052

-0.00050

-0. 00043

-0.00046

-0.00044

-0.00041

-0.00039

-0.00042

-0.00079

-0.00076

-0.00074

-0.00072

-0.00070

-0.00068

-0.00067

-0.00065

-0.00064

-0.00062

-0. 00060

-0. 00058

-0.00056

-0.00054

-0.00052

-0.00050

-0. 00048

-0.00046

-0. 00043

-0. 00041

-0.00038

-0.00042 Rev Nwnber: 0 Sheet Number. 173 of 196 Date: 11/06/02

-0.00079 1454

-0.00076 1455

-0.00073 1456

-0.00071 1457

-0.00070 1458

-0.00068 1459

-0.00067 1460

-0.00065 1461

-0.00063 1462

-0.00062 1463

-0.00060 1464

-0.00058 1465

-0.00056 1466

-0.00054 1467

-0.00052 1468

-0.00050 1469

-0.00048 1470

-0.00045 1471

-0.00043 1472

-0.00041 1473

-0.00038 1474

-0.00042 1475

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 174 of 196 Date: 11/06/02 Appendix C Key Input File For Ground Response Analysis Upper Bound Velocity Profile with 1.6g Excitation using Set 1 Ground Motion

(..\\m37 nms\\input\\m3.lp6g.inp)

option 1

13 11 0.0001 1.

1.000 0.25 11 0.0001 1.

0.24 21.

11 0.0001 1.

1.000 0.080 11 0.0001 1.

0.24 21.

11

0. 0001 1.

1.000

.09 11 0.0001 1.

1.7 20.2 11

0. 0001 1.

1.000 0.18 11 0.0001 2.

1.0 16.9 11 0.0001 2.

1.000 0.28 11

0. 0001 1.

1.0 13.4 11 0.0001 1.

1.000 0.040 11

0. 0001 1.

1.4 27.0 11

0. 0001 1.

1.000 0.060 11 0.0001 1.

1.2 24.9 1 -

dynamic soil properties -

(max is thirteen):

  1. 1 Modulus for generic Clay (idriss 990) 0.0003 0.001 0.003 0.01 0.03
3.

10.

1.000 1.000 0.98 0.94 0.85 0.11 0.04 damping for both clay&sand (idriss 1990) 0.0003 0.001 0.003 0.01 0.03

3.

10.

0.42 0.8 1.4 2.8 5.1

25.

28.

  1. 2 modulus for sand (upper Range sand from seed &

0.0003 0.001 0.003 0.01 0.03

3.

10.

1.000 0.99 0.96 0.85 0.64 0.033 0.013 damping for both clay&sand (idriss 1990) 0.0003 0.001 0.003 0.01 0.03

3.

10.

0.42 0.8 1.4 2.8 5.1

25.

28.

  1. 3 modulus for Clay PI 15 (Vucetic and Dobry 1991) 0.0003 0.001 0.003 0.01 0.03
3.

10.

1.000 1.000

.95

.82

.65

.04

.02 damping for Clay PI 15 (Vucetic & Dobry 1991) 0.0003 0.001 0.003 0.01 0.03

3.

10.

1.7 1.7 2.5 4.5 7.5 22.9 22.9

  1. 4 modulus for Clay PI 30 (Vucetic & Dobry 1991) 0.0003 0.001 0.003 0.01 0.03
3.

10.

1.000 1.000 0.98 0.91 0.74 0.075 0.029 damping for Clay PI 30 (Vucetic & Dobry 1991) 0.0003 0.001 0.003 0.01 0.03

3.

10.

1.0 1.3 2.1 3.9 6.0 20.5 22.3

  1. 5 modulus for Clay PI 50 (Vucetic & Dobry 1991) 0.0003 0.001 0.003 0.01 0.03
3.

10.

1.000 1.000 0.99 0.95 0.84 0.12 0.045 damping for Clay PI 50 (Vucetic & Dobry 1991) 0.0003 0.001 0.003 0.01 0.03

3.

10.

1.0 1.3 1.9 3.0 4.3 17.0 19.8

  1. 6 modulus for Sand (0 to 20 ft) (EPRI 1993) 0.0003 0.001 0.003 0.01 0.03
3.

10.

1.000 0.980 0.914 0.750 0.509 0.017 0.006 damping for Sand (0 to 20 ft) (EPRI 1993) 0.0003 0.001 0.003 0.01 0.03

3.

10.

1.5 1.8 2.8 5.0 9.3 29.0 30.0

  1. 7 modulus for Sand (20 to 50 ft) (EPRI 1993) 0.0003 0.001 0.003 0.01 0.03
3.

10.

1.000 0.990 0.946 0.820 0.608 0.025 0.010 damping for Sand (20 to 50 ft) (EPRI 1993) 0.0003 0.001 0.003 0.01 0.03

3.

10.

1.2 1.4 2.1 3.6 7.0 alc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 175 of 196 Date: 11/06/02 0.1 0.3 0.66 0.44 0.1 9.8 idriss 01.1 0.37 0.1 9.8 0.3 15.5 1970) 0.3 0.18 0.3 15.5 0.1 0.3

.40 0.1 11.7

.21 0.3 15.8 0.1 0.3 0.55 0.35 0.1 8.7 0.1 0.68 0.1 6.2 0.1 0.270 0.1 15.3 0.1 0.360 0.1 12.4 0.3 12.3 0.3 0.47 0.3 9.3 0.3 0.116 0.3 21.9 0.3 0.165 0.3 19.1 27.2 28.9

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 176 of 196 Date: 1 1/06/02 o.c 1.

1.C o.c o.c 1.

1.o 22.

0.0 1.

1.0 0.1 0.0 1.

0.8 21.

0.0 1.

1.0 0.1 0.0 1.

0.7 19.

0.0 1.

1.0' 0.2 0.01 1.

0.6 16.'

O.Ot 1.

1.01 0.34 0.0(

1.

0.24 21.

0.0 1.

1.0(

0.71 0.0C 1.

0.3 5.

Opts 11

  1. 8 modulus for Sand (50 to 120 ft) (EPRI 1993) 1001 0.0003 0.001 0.003 0.01 0.03
3.

10.

00 1.000 1.000 0.970 0.870 0.680 190 0.037 0.014 11 damping for Sand (50 to 120 ft) (EPRI 1993) 001 0.0003 0.001 0.003 0.01 0.03

3.

10.

1.0 1.2 1.64 2.8 5.49 9

25.5 27.0 11

  1. 9 modulus for Sand (120 to 250 ft) (EPRI 1993) 001 0.0003 0.001 0.003 0.01 0.03
3.

10.

'00 1.000 1.000 0.980 0.900 0.740 20 0.050 0.019 11 damping for Sand (120 to 250 ft) (EPRI 1993) 001 0.0003 0.001 0.003 0.01 0.03

3.

10.

0.9 1.0 1.3 2.2 4.4 2

23.8 25.5 11

  1. 10 modulus for Sand (250 to 500 ft) (EPRI 1993) 001 0.0003 0.001 0.003 0.01 0.03
3.

10.

00 1.000 1.000 0.990 0.930 0.810 50 0.080 0.05 11 damping for Sand (250 to 500 ft) (EPRI 1993) 001 0.0003 0.001 0.003 0.01 0.03

3.

10.

0.8 0.8 1.1 1.8 3.5 3

22.4 24.0 11

  1. 11 modulus for Sand (> 500 ft) (EPRI 1993) 001 0.0003 0.001 0.003 0.01 0.03
3.

10.

00 1.000 1.000 0.990 0.950 0.852 0.083 0.032 L

damping for Sand (> 500 ft) (EPRI 1993) 001 0.0003 0.001 0.003 0.01 0.03

3.

10.

0.6 0.6 0.8 1.2 2.5 7

20.2 22.5 LI 112 modulus for Weathered Rock

)01 0.0003 0.001 0.003 0.01 0.03

3.

10.

0 1.000 1.000 0.990 0.960 0.900 4

0.2 0.12 1

damping for Weathered Rock 001 0.0003 0.001 0.003 0.01 0.03

3.

10.

4 0.42 0.8 1.4 2.8 5.1

25.

28.

9

  1. 13 modulus for Competent Rock

)01 0.0003 0.001 0.003 0.01 0.03 0.1 0.3 0.430 0.220 0.1 0.3 10.2 16.5 0.1 0.3 0.500 0.270 0.1 0.3 8.6 14.6 0.1 0.570 0.3 0.330 0.1 0.3 7.1 12.8 0.1 0.65 0.1 5.3 0.3 0.41 0.3 10.3 0.1 0.3 0.75 0.55 0.1 9.8 0.3 15.5 0.1 0.3

)0 9

001 7

.on1 1.000 1.000 0.980 0.960 0.930 0.890 0.840 amping for Competent Rock 0.0003 0.001 0.003 0.4 0.8 1.1 0.01 1.5 0.03 0.1 0.3 2.1

3.

4.

3 7

8 9

10 11 12 2 -- Soil Profile 2

1 46 1

3 2

3 3

3 4

3 5

3 6

3 7

7 8

7 9

7 Idriss interpretation

3.

.050

3.

.050

4.

.050

5.

.050

5.

.050

5.

.050

5.

.050

5.

.050

5.

.050

.125

.125

.125

.125

.125

.125

.130

.130

.130 915.

915.

915.

915.

915.

1220.

1220.

1403.

1403.

10 7

11 7

12 3

13 3

14 8

15 8

16 8

17 8

18 8

19 8

20 8

21 8

22 9

23 3

24 3

25 3

26 3

27 3

28 9

29 9

30 9

31 10 32 10 33 10 34 10 35 10 36 10 37 10 38 10 39 10 40 10 41 10 42 11 43 11 44 11 45 11 46 12 Option 3 --

5.

5.

5.

5.

7.5 7.5 7.5 7.5 10.

11.

12.

12.

15.

13.

13.

13.

13.

13.

15.

15.

15.

20.

20.

20.

20.

20.

20.

20.

25.

25.

25.

25.

25.

25.

25.

25.

input motion:

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.050

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.130

.135 Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 177 of 196 Date: 11/06/02 1403.

1403.

1830.

1830.

1830.

1830.

1830.

1830.

2135.

2135.

2135.

2135.

2440.

1891.

1891.

1891.

1891.

1891.

2013.

2013.

2013.

2440.

2440.

2440.

2196.

2196.

2196.

2196.

2318.

2319.

2440.

2440.

2562.

2562.

2562.

2562.

6100.

(8f9.6) or outcropping 0):

3 6565 8192.005 m78setl.acc 1.6

50.

2 8

Option 4 -- sublayer for input motion (within (1) 4 46 0

Option 5 -- number of iterations & ratio of avg strain to max strain 5

0 12 0.68 option 9 -- compute & save response spectrum:

9 1

0 1

0 0.05 Option 6 --

6 981.0 sublayers for which accn time histories are computed a saved:

1 2

3 4

5 6

7 8

9 0

1 1

1 1

1 1

1 1

1 0

0 0

0 0

0 0

0 Option 6 -- sublayers for which accn time hist 6

16 17 18 19 20 21 22 23 24 1

1 1

1 1

1 1

1 1

0 0

0 0

0 0

0 0

0 Option 6 -- sublayers for which accn time hist 6

31 32 33 34 35 36 37 38 39 1

1 1

1 1

1 1

1 1

0 0

0 0

0 0

0 0

0 Option 6 -- sublayers for which accn time hist 6

46 1

0 execution will stop when program encounters 0 10 1

0 tories 25 1

tories 40 1

0 tories 11 12 13 14 15 1

1 1

1 1

0 0

0 0

0 are computed & saved:

26 27 28 29 30 1

1 1

1 1

0 0

0 0

0 are computed a saved:

41 42 43 44 45 1

1 1

1 1

0 0

0 0

0 are computed & saved:

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number 178 of 196 Date: 11/06/02 0

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 179 of 196 Date: 11/06/02 Appendix D Key Output File For Ground Response Analysis Upper Bound Velocity Profile with 1.6g Excitation using Set 1 Ground Motion

(..\\m37juns\\m3_Ip6g.out)

(

C (f

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 180 of 196 Date: 11/06/02

  • SHAKE:

A COMPUTER PROGRAM FOR EARTHQUAKE RESPONSE ANALYSIS OF HORIZONTALLY*

LAYERED SITES by: Per B.

Schnabel & John Lysmer -- 1970

  • shake85:

IBM-PC version of SHAKE by: S.S. (Willie) Lai, January 1985 *

  • shake98:New modulus reduction curves for clays added using results from Sun*

et al (1988) by: J. I. Sun & Ramin Golesorkhi February 26, 1988 *

  • SHAKE90/91: Adjust last iteration; Input now is either Gmax or max Vs; up *
  • to 13 material types can be specified by user; up to 50 Layers can be
  • specified; object motion can be read in from a separate file and can have
  • user specified format; Different periods for response spectral calcs;
  • options are renumbered; and general cleanup by: J. I. Sun, I. M. Idriss *
  • & P. Dirrim June 1990 - February 1991 *
  • SHAKE91: General cleanup and finalization of input/output format...

etc by: I. M. Idriss December 1991

  • SHAKE96S: Max. no. of values for FFT=16384; write time histories, soil
  • properties, and amplification spectra to separate files; improve response *
  • spectrum calculation for high frequencies by:

D.Hamasaki and W.S.Tseng *

  • This is PC Single Precision Version by: CEC May 3, 1996
  • MAX.

NUMBER OF TERMS IN FOURIER TRANSFORM u 16384 NECESSARY LENGTH OF BLANK COMMON X 102419 ACTUAL LENGTH OF BLANK COMMON X

=

102420 1******

OPTION 1 READ RELATION BETWEEN SOIL PROPERTIES AND STRAIN MATERIAL TYPE NO. 3 CURVE NO.

5:

  1. 3 modulus for Clay PI 15 Vucetic and Dobry 1991)

CURVE NO.

6:

damping for Clay PI 15 (Vucetic & Dobry 1991)

CURVE NO. 5 CURVE NO. 6 a..........

STRAIN G/Gmax STRAIN DAMPING 0__01_

1--000-1_____0_

.0001 1.000

.0001 1.70

.0003 1.000

.0003 1.70

.0010 1.000

.0010 1.70

.0030

.950

.0030 2.50

.0100

.820

.0100 4.50

.0300

.650

.0300 7.50

.1000

.400

.1000 11.70

.3000

.210

.3000 15.80 1.0000

.090 1.0000 20.20 3.0000

.040 3.0000 22.90 10.0000

.020 10.0000 22.90

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 181 of 196 Date: 1 1/06/02 MATERIAL TYPE NO. 7 CURVE NO. 13:

CURVE NO. 14:

CURVE NO.13 STRAIN G/Gmax

.0001 1.000

.0003 1.000

.0010

.990

.0030

.946

.0100

.820

.0300

.608

.1000

.360

.3000

.165 1.0000

.060 3.0000

.025 10.0000

.010

  1. 7 modulus for Sand (20 to 50 ft)

EPRI 1993) damping for Sand (20 to 50 ft) (EPRI 1993)

CURVE NO.14

.=

X

=

STRAIN

.0001---

.0001

.0003

.0010

.0030

.0100

.0300

.1000

.3000 1.0000 3.0000 10.0000 DAMPING 1.20____

1.20 1.20 1.40 2.10 3.60 7.00 12.40 19.10 24.90 27.20 28.90 MATERIAL TYPE NO. 8 CURVE NO. 15:

CURVE NO. 16:

  1. 8 modulus for Sand (50 to 120 ft) (EPRI 1993) damping for Sand (50 to 120 ft) (EPRI 1993)

CURVE NO.15 0....=======...

u.

STRAIN G/Gmax

__0001__

1.000--

.0001 1.000

.0003 1.000

. 0010 1.000

.0030

.970

.0100

.870

.0300

.680

.1000

.430

.3000

.220 1.0000

.090 3.0000

.037 10.0000

.014 CURVE NO.16 w~s=5=-

STRAIN

__0001__

.0001

.0003

.0010

.0030

.0100

.0300

.1000

.3000 1.0000 3.0000 10.0000 DAMPING 1.00 1.00 1.20 1.64 2.80 5.49 10.20 16.50 22.90 25.50 27.00 MATERIAL TYPE NO. 9

(

(

(

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 182 of 196 Date: 11/06/02 CURVE NO. 17:

19 modulus for Sand (120 to 250 ft) (EPRI 1993)

CURVE NO. 18:

damping for Sand (120 to 250 ft)

EPRI 1993)

CURVE NO.17 CURVE N.18

====.==....====..............

======u===.=.

STRAIN G/Gmax STRAIN DAMPING

.0001 1.000

.0001

.80

.0003 1.000

.0003

.90

.0010 1.000

.0010 1.00

.0030

.980

.0030 1.30

.0100

.900

.0100 2.20

.0300

.740

.0300 4.40

.1000

.500

.1000 8.60

.3000

.270

.3000 14.60 1.0000

.120 1.0000 21.20 3.0000

.050 3.0000 23.80 10.0000

.019 10.0000 25.50 MATERIAL TYPE NO.10 CURVE NO. 19:

CURVE NO. 20:

CURVE NO.19 STRAIN G/Gmax

.0001 1.000

.0003 1.000

.0010 1.000

.0030

.990

.0100

.930

.0300

.810

.1000

.570

.3000

.330 1.0000

.150 3.0000

.080 10.0000

.050

  1. 10 modulus for Sand (250 to 500 ft) (EPRI 1993) damping for Sand (250 to 500 ft) (EPRI 1993)

CURVE N.20

======---..

w

sw5=

STRAIN

_.0 0 0_

_ 1

.0001

.0003

.0010

.0030

.0100

.0300

.1000

.3000 1.0000 3.0000 10.0000 DAMPING

.70

.80

.80 1.10 1.80 3.50 7.10 12.80 19.30 22.40 24.00 MATERIAL TYPE NO.11

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 183 of 196 Date: 11/06/02 CURVE NO. 21:

CURVE NO. 22:

  1. 11 modulus for Sand > 500 ft) (EPRI 1993) damping for Sand (> 500 ft) (EPRI 1993)

CURVE NO.21

=

STRAIN

______0_

.0001

.0003

.0010

.0030

.0100

.0300

.1000

.3000 1.0000 3.0000 10.0000 G/Gmax 1.000--

1.000 1.000 1.000

  • .990

.950

.852

.650

.410

.200

.083

.032 CURVE NO.22

=....

STRAIN DAMPING 0_____

6----

.0001

.60

.0003

.60

.0010

.60

.0030

.80

.0100 1.20

.0300 2.50

.1000 5.30

.3000 10.30 1.0000 16.70 3.0000 20.20 10.0000 22.50 MATERIAL TYPE NO.12 CURVE NO. 23:

CURVE NO. 24:

CURVE NO.23 STRAIN G/Gmax

.0001 1.000

.0003 1.000

.0010 1.000

.0030

.990

.0100

.960

.0300

.900

.1000

.750

.3000

.550 1.0000

.340 3.0000

.200 10.0000

.120 112 modulus for Weathered Rock damping for Weathered Rock CURVE NO.24

===.===.=.-...-

STRAIN

_.0_001

.0001

.0003

.0010

.0030

.0100

.0300

.1000

.3000 1.0000 3.0000 10.0000 DAMPING

.24

.42

.80 1.40 2.80 5.10 9.80 15.50 21.00 25.00 28.00 1******

OPTION 2 **,

NEW SOIL PROFILE NO.

NUMBER OF LAYERS NO. TYPE THICKNESS (ft)

  • READ SOIL PROFILE 1

IDENTIFICATION 46 Idriss interpretation DEPTH TO BEDROCK 600.00 DEPTH Tot.

PRESS.

MODULUS DAMPING UNIT WT.

SHEAR VEL (ft)

(ksf)

(ksf)

(kcf)

(fps)

(

C

(

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 184 of 196 Date: 11/06/02 1

3 3.00 1.50

.19 3250.

.050

.125 915.0 2

3 3.00 4.50

.47 3250.

.050

.125 915.0 3

3 4.00 8.00

.69 3250.

.050

.125 915.0 4

3 5.00 12.50

.97 3250.

.050

.125 915.0 5

3 5.00 17.50 1.28 3250.

.050

.125 915.0 6

3 5.00 22.50 1.60 5778.

.050

.125 1220.0 7

7 5.00 27.50 1.92 6009.

.050

.130 1220.0 8

7 5.00 32.50 2.26 7947.

.050

.130 1403.0 9

7 5.00 37.50 2.60 7947.

.050

.130 1403.0 10 7

5.00 42.50 2.94 7947.

.050

.130 1403.0 11 7

5.00 47.50 3.27 7947.

.050

.130 1403.0 12 3

5.00 52.50 3.61 13520.

.050

.130 1830.0 13 3

5.00 57.50 3.95 13520.

.050

.130 1830.0 14 8

7.50 63.75 4.37 13520.

.050

.130 1830.0 15 8

7.50 71.25 4.88 13520.

.050

.130 1830.0 16 8

7.50 78.75 5.39 13520.

.050

.130 1830.0 17 8

7.50 86.25 5.89 13520.

.050

.130 1830.0 18 8

10.00 95.00 6.48 18403.

.050

.130 2135.0 19 8

11.00 105.50 7.19 18403.

.050

.130 2135.0 20 8

12.00 117.00 7.97 18403.

.050

.130 2135.0 21 8

12.00 129.00 8.78 18403.

.050

.130 2135.0 22 9

15.00 142.50 9.70 24036.

.050

.130 2440.0 23 3

13.00 156.50 10.64 14437.

.050

.130 1891.0 24 3

13.00 169.50 11.52 14437.

.050

.130 1891.0 25 3

13.00 182.50 12.40 14437.

.050

.130 1891.0 26 3

13.00 195.50 13.28 14437.

.050

.130 1891.0 27 3

13.00 208.50 14.16 14437.

.050

.130 1891.0 28 9

15.00 222.50 15.10 16360.

.050

.130 2013.0 29

9.

15.00 237.50 16.12 16360.

.050

.130 2013.0 30 9

15.00 252.50 17.13 16360.

.050

.130 2013.0 31 10 20.00 270.00 18.31 24036.

.050

.130 2440.0 32 10 20.00 290.00 19.67 24036.

.050

.130 2440.0 33 10 20.00 310.00 21.02 24036.

.050

.130 2440.0 34 10 20.00 330.00 22.37 19469.

.050

.130 2196.0 35 10 20.00 350.00 23.72 19469.

.050

.130 2196.0 36 10 20.00 370.00 25.07 19469.

.050

.130 2196.0 37 10 20.00 390.00 26.43 19469.

.050

.130 2196.0 38 10 25.00 412.50 27.95 21693.

.050

.130 2318.0 39 10 25.00 437.50 29.64 21693.

.050

.130 2318.0 40 10 25.00 462.50 31.33 24036.

.050

.130 2440.0 41 10 25.00 487.50 33.02 24036.

.050

.130 2440.0 42 11 25.00 512.50 34.71 26500.

.050

.130 2562.0 43 11 25.00 537.50 36.40 26500.

.050

.130 2562.0 44 11 25.00 562.50 38.09 26500.

.050

.130 2562.0 45 11 25.00 587.50 39.78 26500.

.050

.130 2562.0 46 BASE 156005.

.050

.135 6100.0 PERIOD = 1.11 FROM AVERAGE SHEAR VELOCITY =

2157.

MAXIMUM AMPLIFICATION =

13.34

Cale Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 185 of 196 Date: 11/06/02 FOR FREQUENCY

.97 C/SEC.

PERIOD 1.03 SEC.

1******

OPTION 3

READ INPUT MOTION FILE NAME FOR INPUT MOTION = m78setl.acc NO.

OF INPUT ACC.

POINTS a 6565 NO.

OF POINTS USED IN FFT =

8192 NO.

OF HEADING LINES -

2 NO.

OF POINTS PER LINE =

8 TIME STEP FOR INPUT MOTION -

.0050 FORMAT FOR OF TIME HISTORY a (8f9.6)

          • H E A D R

Time history matched to spectrum:::SetTarget:M78_D005_RVJHW.target 6565 0.0050 FIRST E LAST 5 LINES OF INPUT MOTION

  • 1

.007300

.007220

.007150

.007080

.007020

.006960

.00690C 2

.006790

.006720

.006660

.006590

.006520

.006460

.00639(

3

.006260

.006200

.006140

.006080

.006020

.005960

.00591C 4

.005790

.005730

.005670

.005610

.005550

.005490

.00542C 5

.005260

.005180

.005080

.004980

.004860

.004730

.00458C

........ INPUT MOTION READ NOT ECHOED.

817

-.005350 -.005290 -.005220 -.005150 -.005090 -.005020 -.00495(

818

-. 004820 -. 004750 -. 004690 -. 004620 -. 004550 -. 004480 -. 00442(

819

-. 004280 -. 004210 -. 004140 -. 004070 -. 004000 -. 003930 -. 00386C 820

-. 003720 -. 003650 -. 003580 -. 003510 -. 003430 -. 003360 -. 00329C 821

-. 003140 -. 003070 -. 002990 -. 002920 -. 002840

.000000

.00000(

MAXIMUM ACCELERATION =

.89226 AT TIME

  • 10.50 SEC THE VALUES WILL BE MULTIPLIED BY A FACTOR -

1.793 TO GIVE NEW MAXIMUM ACCELERATION 1.60000 MEAN SQUARE FREQUENCY =

4.00 C/SEC.

MAX ACCELERATION -

1.64242 FOR FREQUENCIES REMOVED ABOVE 50.

1******

OPTION 4

READ WHERE OBJECT MOTION IS GIVEN OBJECT MOTION IN LAYER NUMBER 46 OUTCROPPING 1******

OPTION 5

OBTAIN STRAIN COMPATIBLE SOIL PROPERTIES MAXIMUM NUMBER OF ITERATIONS

=

12 FACTOR FOR UNIFORM STRAIN IN TINE DOMAIN

=

.68 EARTHQUAKE

- m78setl.acc SOIL PROFILE -

Idriss interpretation ITERATION NUMBER 1

VALUES IN TIME DOMAIN

.006850

.006330

.005850

.005340

.004420

-. 004890

-. 004350

-. 003790

-. 003210

.000000

.00 C/SEC.

K

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 186 of 196 Date: 11/06/02 NO TYPE DEPTH UNIFRM.

<---- DAMPING ----

<---- SHEAR MODULUS ----- >

G/Go (FT)

STRAIN NEW USED ERROR NEW USED ERROR RATIO 1

3 1.5

.00816

.042

.050

-20.1 2736.3 3250.1

-18.8 1.000 2

3 4.5

.02440

.069

.050 27.9 2216.6 3250.1

-46.6 1.000 3

3 8.0

.04298

.088

.050 42.9 1869.9 3250.1

-73.8 1.000 4

3 12.5

,06589

.102

.050 51.2 1581.6 3250.1

-105.5 1.000 5

3 17.5

.08941

.113

.050 55.8 1375.6 3250.1

-136.3 1.000 6

3 22.5

.06249

.101

.050 50.3 2875.4 5778.0

-100.9 1.000 7 7 27.5

.07256

.110

.050 54.4 2560.3 6009.1

-134.7 1.000 8 7 32.5

.06406

.104

.050 51.9 3590.0 7947.0

-121.4 1.000 9

7 37.5

.07283

.110

.050 54.5 3380.0 7947.0

-135.1 1.000 10 7

42.5

.08112

.115

.050 56.4 3203.5 7947.0

-148.1 1.000 11 7

47.5

.08887

.119

.050 57.9 3054.1 7947.0

-160.2 1.000 12 3

52.5

.05646

.097

.050 48.5 7012.9 13520.4

-92.8 1.000 13 3

57.5

.06045

.099

.050 49.7 6821.4 13520.4

-98.2 1.000 14 8

63.8

.06510

.085

.050 41.3 7018.8 13520.4

-92.6 1.000 15 8

71.3

.07018

.088

.050 43.3 6807.7 13520.4

-98.6 1.000 16 8

78.8

.07541

.091

.050 45.0 6606.2 13520.4

-104.7 1.000 17 8 86.3

.08057

.094

.050 46.6 6420.2 13520.4

-110.6 1.000 18 8 95.0

.06326

.084

.050 40.5 9663.2 18402.8

-90.4 1.000 19 8 105.5

.06772

.087

.050 42.4 9402.5 18402.8

-95.7 1.000 20 8 117.0

.07219

.089

.050 44.0 9158.6 18402.8

-100.9 1.000 21 8 129.0.07633

.091

.050 45.3 8945.5 18402.8

-105.7 1.000 22 9 142.5

.06169

.069

.050 27.7 14332.3 24036.3

-67.7 1.000 23 3

156.5

.10786

.120

.050 58.3 5585.7 14436.8

-158.5 1.000 24 3

169.5

.11155

.121

.050 58.7 5501.8 14436.8

-162.4 1.000 25 3

182.5

.11890

.123

.050 59.5 5342.5 14436.8

-170.2 1.000 26 3 195.5

.12580

.126

.050 60.2 5201.7 14436.8

-177.5 1.000 27 3

208.5

.13214

.127

.050 60.8 5078.9 14436.8

-184.2 1.000 28 9 222.5

.12204

.097

.050 48.4 7497.5 16359.7

-118.2 1.000 29 9 237.5

.12725

.099

.050 49.6 7354.5 16359.7

-122.4 1.000 30 9 252.5

.13188

.101

.050 50.5 7232.2 16359.7

-126.2 1.000 31 10 270.0

.09302

.069

.050 27.4 14047.2 24036.3

-71.1 1.000 32 10 290.0

.09637

.070

.050 28.5 13877.6 24036.3

-73.2 1.000 33 10 310.0

.09939

.071

.050 29.4 13730.0 24036.3

-75.1 1.000 34 10 330.0.12597

.083

.050 39.7 10115.4 19469.4

-92.5 1.000 35 10 350.0

.12875

.084

.050 40.6 10022.8 19469.4

-94.3 1.000 36 10 370.0

.13102

.085

.050 41.2 9948.5 19469.4

-95.7 1.000 37 10 390.0

.13280

.086

.050 41.7 9891.0 19469.4

-96.8 1.000 38 10 412.5.12050

.081

.050 38.0 11481.2 21692.7

-88.9 1.000 39 10 437.5.12135

.081

.050 38.3 11448.0 21692.7

-89.5 1.000 40 10 462.5

.10985

.076

.050 34.1 13207.3 24036.3

-82.0 1.000 41 10 487.5

.11001

.076

.050 34.2 13199.9 24036.3

-82.1 1.000 42 11 512.5

.10103

.053

.050 6.5 17165.4 26500.0

-54.4 1.000 43 11 537.5

.10196

.054

.050 7.2 17112.8 26500.0

-54.9 1.000 44 11 562.5.10229

.054

.050 7.5 17093.7 26500.0

-55.0 1.000 45 11 587.5.10202

.054

.050 7.3 17109.0 26500.0

-54.9 1.000 1

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 187 of 196 Date: 11/06/02 EARTHQUAKE

- m78setl.acc SOIL PROFILE -

Idriss interpretation Skip results from iteration 2 through 11.............

ITERATION NUMBER 12 VALUES IN TIME DOMAIN NO TYPE DEPTH UNIFRM.

<---- DAMPING ----

<---- SHEAR MODULUS ----- >

(FT)

STRAIN NEW USED ERROR NEW USED ERROR 1 3 1.5

.00568

.036

.036 2

3 4.5-.02081

.065

.065 3

3 8.0

.04539

.089

.090 4 3 12.5

.09448

.115

.115 5

3 17.5

.17902

.139

.139 6 3 22.5

.08833

.113

.113 7 7 27.5

.14948

.149

.149 8 7 32.5

.10973

.130

.130 9 7 37.5

.14660

.147

.148 10 7

42.5

.20481

.168

.168 11 7

47.5

.32746

.195

.195 12 3

52.5

.07256

.106

.106 13 3

57.5

.08284

.110

.110 14 8

63.8

.08617

.096

.096 15 8

71.3

.10127

.103

.103 16 8 78.8

.11645

.111

.111 17 9 86.3

.13250

.118

.118 18 8 95.0

.08597

.096

.096 19 8 105.5

.09846

.101

.101 20 8 117.0

.11771

.111

.111 21 8 129.0

.13921

.121

.121 22 9

142.5

.07880

.078

.078 23 3 156.5

.42026

.170

.170 24 3 169.5

.46504

.174

.174 25 3 182.5

.49471

.176

.176 26 3 195.5

.50712

.177

.177 27 3 208.5

.50338.177

.177 28 9 222.5

.20699

.126

.126 29 9 237.5

.20299

.125

.125 30 9 252.5

.20897

.126

.126 31 10 270.0

.08525

.066

.066 32 10 290.0

.09635

.070

.070 33 10 310.0

.11388

.078

.078 34 10 330.0

.20056

.107

.107 35 10 350.0

.23420

.115

.115 36 10 370.0

.26858

.122

.122 37 10 390.0

.29942

.128

.128 38 10 412.5

.24117

.117

.117 0

2863.7

-.1 2296.5

-1 1833.1

-.1 1338.4

-.2 972.7

-.1 2460.1

-.4 1734.5

-.1 2730.0

-.2 2321.3

-. 3 1849.6 0

1250.5 0

6308.5

.0 5936.8 0

6231.6 0

5781.1

-.1 5420.1

-.1 5086.4

.0 8490.7

-.1 7972.6

-.1 7339.6

-.1 6749.5 0

13159.9 0

2546.7 0

2401.0 0

2312.0

.0 2276.3

.0 2287.0

-.1 5688.1

-.1 5755.1

-.1 5655.5 0

14465.1 0

13878.9 0

13018.2 0

8137.5 0

7478.0 1

6895.5 1

6433.1

.0 8193.1 2863.3 2295.8 1831.7 1335.6 968.2 2455.8 1725.3 2725.6 2314.5 1839.0 1250.0 6305.2 5932.7 6228.5 5779.0 5417.6 5083.4 8488.4 7962.3 7332.2 6743.2 13156.9 2546.8 2402.1 2313.6 2277.8 2287.9 5683.4 5748.5 5649.8 14467.3 13875.7 13015.1 8136.7 7479.9 6902.0 6444.7 8194.5 0_

.0

.0

.1

.2

.5

.2

.5

.2

.3

.6

.0

.1

.1

.0

.0

.0

.1

.0

.1

.1

.1

.0

.0

.0

-. 1

-. 1

.0

.1

.1

.0

.0

.0

.0

.0

-.1

-. 2

.0 G/Go RATIO

.881

.706

.564

.411

.298

.425

.287

.343

.291

.231

.157

.466

.439

.461

.427

.401

.376

.461

.433

.398

.366

.547

.176

.166

.160

.158

.158

.347

.351

.345

.602

.577

.541

.418

.384

.355

.331

.378

(

(.

C

(

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 188 of 196 Date: 11/06/02 39 10 437.5 40 10 462.5 41 10 487.5 42 11 512.5 43 11 537.5 44 11 562.5 45 11 587.5

.25141

.20088

.20599

.13283

.14331

.15165

.15725

.119

.107

.108

.066

.069

.072

.074

.119

.107

.109

.066

.069

.072

.074

.0 7995.9

.0 10038.0

.0 9906.2

.0 15581.5

.0 15142.0

.0 14814.5

.0 14604.3 7994.9 10034.5 9904.7 15581.2 15141.4 14813.5 14602.9

.0

.369

.0

.417

.0

.412

.0

.588

.0

.571

.0

.559

.0

.551 VALUES IN TIME DOMAIN LAYER TYPE 1

3 2

3 3

3 4

3 5

3 6

3 7

7 8

7 9

7 10 7

11 7

12 3

13 3

14 8

15 8

16 8

17 8

18 8

19 8

20 8

21 8

22 9

23 3

24 3

25 3

26 3

27 3

28 9

29 9

30 9

31 10 32 10 33 10 34 10 35 10 36 10 37 10 THICKNESS T

3.0 3.0 4.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 7.5 7.5 7.5 7.5 10.0 11.0 12.0 12.0 15.0 13.0 13.0 13.0 13.0 13.0 15.0 15.0 15.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 DEPTH MAX STRAIN MAX STRESS FT PRCNT PSF 1.5 4.5 8.0 12.5 17.5 22.5 27.5 32.5 37.5 42.5 47.5 52.5 57.5 63.8 71.3 78.8 86.3 95.0 105.5 117.0 129.0 142.5 156.5 169.5 182.5 195.5 208.5 222.5 237.5 252.5 270.0 290.0 310.0 330.0 350.0 370.0 390.0

.00835

.03060

.06675

.13894

.26327

.12990

.21983

.16137

.21559

.30120

.48156

.10671

.12182

.12672

.14893

.17126

.19486

.12643

.14479

.17311

.20472

.11588

.61802

.68389

.72751

.74577

.74026

.30440

.29851

.30732

.12537

.14169

.16747

.29495

.34441

.39497

.44033 239.09 702.56 1222.67 1855.64 2548.97 3189.96 3792.69 4398.19 4989.76 5538.99 6019.78 6728.32 7227.19 7892.99 8606.56 9277.94 9905.48 10731.96 11528.51 12692.41 13804.84 15245.91 15739.54 16427.33 16831.56 16987.51 16936.03 17300.39 17159.77 17362.71 18137.94 19660.21 21796.34 23998.72 25761.71 27260.68 28378.13 TIME SEC 12.23 12.23 12.23 12.24 11.00 12.24 11.00 13.24 13.24 13.24 13.24 13.22 13.22 13.22 13.22 13.22 13.22 13.21 12.32 12.32 12.32 12.31 12.33 12.33 12.34 12.34 12.33 12.30 12.29 12.43 13.34 12.51 12.51 12.52 12.52 12.52 12.52

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 189 of 196 Date: 11/06/02 38 10 39 10 40 10 41 10 42 11 43 11 44 11 45 11 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 412.5 437.5 462.5 487.5 512.5 537.5 562.5 587.5

.35466

.36973

.29541

.30292

.19534

.21075

.22301

.23125 29062.49 29559.29 29642.94 30003.52 30435.79 31909.94 33035.52 33769.91 12.51 12.49 12.48 12.62 12.60 12.60 12.59 12.59 PERIOD = 1.73 FROM AVERAGE SHEAR VELOCITY =

1390.

MAXIMUM AMPLIFICATION =

FOR FREQUENCY

=

PERIOD 5.78

.60 C/SEC.

1.68 SEC.

1******

OPTION 9

      • COMPUTE RESPONSE SPECTRUM RESPONSE SPECTRUM ANALYSIS FOR LAYER NMBER CALCULATED FOR DAMPING

.050 1

TIMES AT WHICH MAX.

SPECTRAL VALUES OCCUR TD - TIME FOR MAX.

RELATIVE DISP.

TV - TIME FOR MAX.

RELATIVE VEL.

TA = TIME FOR MAX.

ABSOLUTE ACC.

DAMPING RATIO

.05 PER -

.01 TIMES FOR MAXIMA--

TD =

PER =

.03 TIMES FOR MAXIMA --

TD -

PER -

.04 TIMES FOR MAXIMA --

TD -

PER =

.05 TIMES FOR MAXIMA --

TD -

PER -

.06 TIMES FOR MAXIMA--

TD -

PER =

.07 TIMES FOR MAXIMA --

TD -

PER u

.08 TIMES FOR MAXIMA --

TD -

PER -

.09 TIMES FOR MAXIMA --

TD -

PER -

.10 TIMES FOR MAXIMA --

TD -

PER =

.11 TIMES FOR MAXIMA --

TD =

PER -

.12 TIMES FOR MAXIMA --

TD =

PER =

.13 TIMES FOR MAXIMA --

TD a PER -

.14 TIMES FOR MAXIMA --

TD -

PER a

.15 TIMES FOR MAXIMA --

TD =

PER -

.16 TIMES FOR MAXIMA --

TD =

PER =

.17 TIMES FOR MAXIMA --

TD -

PER -

.18 TIMES FOR MAXIMA--

TD =

PER =

.19 TIMES FOR MAXIMA --

TD =

PER -

.20 TIMES FOR MAXIMA --

TD -

PER *.21 TIMES FOR MAXIMA --

TD a PER =

.22 TIMES FOR MAXIMA --

TD -

PER =

.23 TIMES FOR MAXIMA --

TD =

PER =

.24 TIMES FOR MAXIMA --

TD =

PER -

.25 TIMES FOR MAXIMA --

TD -

PER -

.26 TIMES FOR MAXIMA --

TD w PER =

.27 TIMES FOR MAXIMA --

TD =

12.2280 12.2275 12.2275 12.2300 12.2300 12.2300 12.2250 12.2300 12.2350 10.9850 10.9950 12.2300 10.9950 12.2100 12.2300 12.2500 14.2500 13.1550 13.1700 10.9750 10.9900 11.0000 11.0100 11.1700 11.1800 11.1900 TV a 11.0700 TV = 11.0700 TV = 11.0700 TV - 11.0700 TV - 11.0700 TV = 11.0700 TV

  • 11.0800 TV = 11.0900 TV = 12.1250 TV = 11.4950 TV = 11.0400 TV - 11.0550 TV - 11.6000 TV = 11.0600 TV = 11.0800 TV - 11.1000 TV = 10.8700 TV = 10.8800 TV = 10.8950 TV a 13.6550 TV - 10.9250 TV = 11.0750 TV = 11.0850 TV = 11.1000 TV = 11.1100 TV = 11.6650 TA = 12.2280 TA = 12.2275 TA - 12.2275 TA - 12.2300 TA = 12.2300 TA - 12.2250 TA = 12.2250 TA = 12.2250 TA = 12.2350 TA = 10.9850 TA - 10.9900 TA = 12.2250 TA - 10.9950 TA - 12.2100 TA - 12.2250 TA = 12.2500 TA = 14.2450 TA - 13.1500 TA = 13.1650 TA = 10.9700 TA - 10.9850 TA - 11.0000 TA w 11.0100 TA a 11.1650 TA - 11.1750 TA = 11.1850

(,

(

(

C Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 190 of 196 Date: 11/06/02 PER -

PER =

PER =

PER =

PER =

PER =

PER =

PER =

PER -

PER -

PER =

PER =

PER -

PER -

PER =

PER -

PER a PER =

PER =

PER =

PER -

PER =

PER -

PER =

PER -

PER =

PER -

PER =

PER =

PER -

PER =

PER =

PER -

PER =

PER =

PER -

PER =

PER w PER -

PER =

PER =

PER =

PER a PER =

PER =

PER w PER -

PER =

PER =

PER =

.28

.29

.30

.31

.32

.33

.34

.35

.36

.37

.38

.39

.40

.41

.42

.43

.44

.45

.46

.47

.48

.49

.50

.51

.52

.53

.54

.55

.56

.57

.58

.60

.62

.64

.66

.68

.70

.72

.74

.76

.78

.80

.82

.84

.86

.88

.90

.92

.94

.96 TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES TIMES FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA --

FOR MAXIMA FOR MAXIMA FOR MAXIMA FOR MAXIMA FOR MAXIMA FOR MAXIMA FOR MAXIMA FOR MAXIMA FOR MAXIMA FOR MAXIMA FOR MAXIMA FOR MAXIMA FOR MAXIMA FOR MAXIMA T

TD =

TD =

TD =

TD =

TD =

TD =

TD -

TD =

TD e TD =

TD -

TD =

TD X TD =

TD -

TD -

TD =

TD -

TD =

TD TD -

TD =

TD =

TD =

TD a TO =

TO -

TD -

TD =

TD =

TD =

TD =

TD =

TD =

TD TD =

TD a 7D-TD =

TD =

TD =

TD =

TD -

TD =

TD =

TD =

TD a TD a TD =

13.2350 13.2550 12.2650 12.2850 12.3000 12.3150 11.2400 11.2450 11.2450 11.2550 11.2600 11.2700 12.3300 12.3500 12.3650 12.3850 12.4000 11.3200 11.3250 11.3300

11. 8450 11.8600 11.8700 11.8800 11.8850 11.8950 11.9050 11.9150 11.3750 12.2950 12.3150 12.3500 13.3300 13.3600 13.3900 12.4550 12.4750 12.5000 12.5350 5.9100 5.9250 5.9350 5.9450 5.9600 6.4100 6.4300 6.4500 6.4700 6.4900 6.5050 TV TV =

TV =

TV =

TV.

TV TV TV =

TV TV =

TV TV =

TV TV =

TV a TV -

TV TV =

TV TV TV =

TV =

TV TV TV =

TV =

TV =

TV -

TV =

TV =

TV TV =

TV =

TV =

TV -

TV -

TV =

TV TV -

TV =

TV =

TV =

TV =

TV TV TV =

TV =

TV =

TV =

TV =

11.6800 14.9850 13.6900 13.7100 12.3750 11.1500 13.7300 13.7400 13.7550 13.7650 13.6000 13.6050 13.6200 11.1900 12.2700 12.2800 12.9600 11.2050 11.2050 11.9450 11.7250 11.7350 11.7500 11.7550 11.7600 11.7700 11.7750 11.7850 11.7950 11.8050 11.5550 13.4550 13.4800 13.5000 13.5250 12.6250 12.6450 12.6650 6.0850 6.1000 6.1200 6.1350 6.1550 6.1700 6.1850 6.2000 6.2200 6.2350 6.2500 6.2600 TA - 13.2300 TA

  • 13.2500 TA a 12.2600 TA = 12.2800 TA = 12.2950 TA = 12.3100 TA = 11.2350 TA 11.2350 TA - 11.2400 TA = 11.2500 TA = 11.2550 TA - 11.2650 TA = 12.3250 TA - 12.3400 TA - 12.3600 TA = 12.3750 TA = 12.3950 TA a 11.3100 TA

= 11.3150 TA -

11.3250 TA = 11.8350 TA a 11.8500 TA = 11.8600 TA - 11.8700 TA = 11.8750 TA = 11.8850 TA e 11.8950 TA - 11.9050 TA = 11.3650 TA

  • 11.3750 TA - 12.3050 TA = 12.3400 TA = 13.3250 TA = 13.3500 TA - 13.3800 TA 12.4450 TA = 12.4650 TA = 12.4900 TA - 12.5250 TA -

5.9000 TA -

5.9100 TA -

5.9200 TA -

5.9350 TA -

5.9450 TA =

6.3950 TA

  • 6.4150 TA w 6.4350 TA -

6.4550 TA -

6.4750 TA =

6.4900

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 191 of 196 Date: 11/06/02 PER =

.98 TIMES FOR MAXIMA --

TD -

6.5250 TV -

6.2750 TA =

6.5100 PER = 1.00 TIMES FOR MAXIMA --

TD -

6.5450 TV -

6.2900 TA =

6.5300 PER = 1.05 TIMES FOR MAXIMA --

TD

  • 6.5950 TV -

6.3250 TA =

6.5800 PER = 1.10 TIMES FOR MAXIMA --

TD =

8.3600 TV =

6.9500 TA =

8.3400 PER = 1.15 TIMES FOR MAXIMA --

TD =

8.4450 TV =

8.1700 TA =

8.4300 PER = 1.20 TIMES FOR MAXIMA --

TD =

9.7700 TV = 10.0550 TA -

9.7500 PER = 1.25 TIMES FOR MAXIMA --

TD = 12.4900 TV -

9.5550 TA

  • 12.4700 PER = 1.30 TIMES FOR MAXIMA --

TD - 12.5850 TV = 12.9450 TA = 12.5650 PER = 1.35 TIMES FOR MAXIMA --

TD - 13.4250 TV = 14.5400 TA = 13.4050 PER = 1.40 TIMES FOR MAXIMA --

TD -

14.9850 TV - 14.6800 TA - 14.9600 PER -

1.45 TIMES FOR MAXIMA --

TO - 15.0650 TV -

14.7350 TA a 15.0400 PER = 1.50 TIMES FOR MAXIMA --

TD - 15.1200 TV a 14.7600 TA = 15.1000 PER - 1.55 TIMES FOR MAXIMA --

TO = 15.1750 TV = 14.7800 TA - 15.1500 PER = 1.60 TIMES FOR MAXIMA --

TD - 15.2250 TV = 14.8000 TA = 15.2000 PER - 1.65 TIMES FOR MAXIMA -~

TO = 16.9650 TV a 15.7200 TA a 16.9400 PER = 1.70 TIMES FOR MAXIMA--

TD - 17.0400 TV = 16.6300 TA - 17.0150 PER = 1.75 TIMES FOR MAXIMA --

TD = 17.1150 TV = 16.6800 TA = 17.0850 PER = 1.80 TIMES FOR MAXIMA --

TD = 17.1850 TV - 15.8650 TA = 17.1550 PER = 1.85 TIMES FOR MAXIMA --

TD = 15.5100 TV - 15.0800 TA - 15.4850 PER = 1.90 TIMES FOR MAXIMA --

TD = 15.5550 TV = 14.2850 TA - 15.5250 PER = 1.95 TIMES FOR MAXIMA --

TD - 14.6900 TV -

14.2950 TA = 14.6600 PER = 2.00 TIMES FOR MAXIMA --

TD = 14.7250 TV = 14.3100 TA = 14.6900 PER - 2.05 TIMES FOR MAXIMA --

TD - 13.8800 TV - 14.3250 TA = 13.8450 PER - 2.10 TIMES FOR MAXIMA --

TD e 13.9100 TV - 14.3400 TA = 13.8750 PER = 2.15 TIMES FOR MAXIMA --

TD w 13.9400 TV = 14.3600 TA = 13.9100 PER = 2.20 TIMES FOR MAXIMA --

TD a 13.9700 TV = 14.3750 TA = 13.9350 PER = 2.25 TIMES FOR MAXIMA --

TD = 13.9950 TV = 14.3850 TA -

13.9600 PER = 2.30 TIMES FOR MAXIMA --

TD e 14.0150 TV = 14.3950 TA

  • 13.9800 PER = 2.35 TIMES FOR MAXIMA --

TD -

14.0350 TV - 13.6150 TA = 14.0000 PER = 2.40 TIMES FOR MAXIMA --

TD - 14.0600 TV = 13.6200 TA -

14.0200 PER = 2.50 TIMES FOR MAXIMA --

TD a 14.1000 TV -

13.6250 TA = 14.0600 PER = 2.60 TIMES FOR MAXIMA --

TD = 14.1450 TV -

13.6350 TA = 14.1050 PER = 2.70 TIMES FOR MAXIMA --

TD - 14.1750 TV -

13.6400 TA -

14.1350 PER a 2.80 TIMES FOR MAXIMA --

TO - 13.1550 TV - 13.6500 TA - 13.1100 PER = 2.90 TIMES FOR MAXIMA --

TO - 13.1650 TV -

13.6550 TA - 13.1250 PER a 3.00 TIMES FOR MAXIMA --

TD = 13.1750 TV = 13.6600 TA - 13.1300 PER = 3.10 TIMES FOR MAXIMA --

TO = 13.1900 TV = 13.6650 TA = 13.1400 PER = 3.20 TIMES FOR MAXIMA --

TO - 13.2000 TV a 13.6750 TA - 13.1500 PER = 3.30 TIMES FOR MAXIMA --

TO -

13.2100 TV = 13.6850 TA = 13.1650 PER - 3.40 TIMES FOR MAXIMA --

TD = 13.2250 TV -

13.8050 TA = 13.1750 PER a 3.50 TIMES FOR MAXIMA --

TD = 13.2400 TV -

12.8250 TA -

13.1850 PER = 3.60 TIMES FOR MAXIMA --

TD = 13.2550 TV -

12.8300 TA = 13.1950 PER = 3.70 TIMES FOR MAXIMA --

TD -

13.2650 TV w 12.8350 TA = 13.2100 PER = 3.80 TIMES FOR MAXIMA --

TD = 13.2850 TV -

12.8400 TA = 13.2200 PER - 3.90 TIMES FOR MAXIMA --

TD = 13.3000 TV = 12.8450 TA = 13.2300 PER = 4.00 TIMES FOR MAXIMA --

TD - 13.3150 TV a 12.8450 TA = 13.2400 PER - 4.10 TIMES FOR MAXIMA --

TO = 15.6700 TV = 12.8500 TA - 15.6050 PER = 4.20 TIMES FOR MAXIMA --

TD = 15.7150 TV = 12.8550 TA = 15.6500 PER = 4.30 TIMES FOR MAXIMA --

TD = 15.7550 TV -

12.8550 TA a 15.6850 PER = 4.40 TIMES FOR MAXIMA --

TD = 15.7900 TV = 12.8600 TA = 15.7150 K

(

(

(

PER a 4.50 PER = 4.60 PER -

4.70 PER = 4.80 PER = 4.90 PER = 5.00 PER = 5.10 PER = 5.20 PER - 5.40 PER = 5.60 PER = 5.80 PER a 6.00 PER = 6.20 PER - 6.40 PER = 6.60 PER a 6.80 PER - 7.00 PER - 7.20 PER -

7.40 PER = 7.60 PER - 7.80 PER = 8.00 PER = 8.50 PER = 9.00 PER - 9.50 PER.10.00 TIMES FOR MAXIMA -

TIMES FOR MAXIMA TIMES FOR MAXIMA -

TIMES FOR MAXIMA -

TIMES FOR MAXIMA TIMES FOR MAXIMA -

TIMES FOR MAXIMA -

TIMES FOR MAXIMA TIMES FOR MAXIMA TIMES FOR MAXIMA TIMES FOR MAXIMA TIMES FOR MAXIMA TIMES FOR MAXIMA TIMES FOR MAXIMA -

TIMES FOR MAXIMA TIMES FOR MAXIMA TIMES FOR MAXIMA -

TIMES FOR MAXIMA -

TIMES FOR MAXIMA TIMES FOR MAXIMA TIMES FOR MAXIMA -

TIMES FOR MAXIMA -

TIMES FOR MAXIMA TIMES FOR MAXIMA -

TIMES FOR MAXIMA TIMES FOR MAXIMA -

TD TD TD TO TD TD TD TO TD TD TD TO TD TD TD TD TO TD TD TD TO TD TD TD TD TD

  • 32.2600

= 30.1800

= 30.3500

= 30.5150

= 21.7700

= 21.8500

= 21.9600 a 22.0500

= 22.1800 a 19.8450

= 19.9200

- 20.0200

= 20.1150

- 20.1600

= 30.7800

- 30.9950

= 31.2150

- 28.2800

= 28.4300

- 28.5750

= 28.7350

= 28.8950

- 25.8850

= 26.0350

  • 26.1600

- 17.9700 TV = 12.8600 TV = 12.8650 TV = 12.8650 TV a 12.8650 TV - 12.8650 TV a 12.8650 TV - 12.8650 TV = 12.8650 TV = 12.8700 TV = 12.8700 TV = 12.8650 TV - 12.8650 TV = 12.8650 TV -

12.8650 TV a 12.8650 TV -

12.8650 TV -

12.8650 TV = 12.8650 TV -

12.8650 TV - 12.8650 TV = 12.8650 TV -

12.8650 TV = 12.8650 TV = 12.8650 TV = 12.8650 TV = 12.8650 TA =

TA =

TA =

TA TA =

TA =

TA =

TA -

TA -

TA =

TA -

TA -

TA =

TA -

TA =

TA -

TA =

TA a TA -

TA =

TA =

TA a TA TA =

TA =

TA =

1.1850

).1100 0.2750 1.4400 L.6950

!.7550 L.8900 1.9650

!.1100 9.7450 9.8300

.. 9000

!.0500

!.0900 3.6750 1.8850 L.1050 3.1650

!.3150 3.4550 3.6000 3.7600 5.7350 5.9000 5.9950 7.7350

.05 PSU.ABS.ACC.

1.30350 1.30984 1.31557 1.32276 1.33201 1.34283 1.35613 1.40580 1.45637 1.42078 1.48182 1.41174 1.53876 1.71192 1.92218 1.91907 1.84436 1.95887 2.20867 2.36012 Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 192 of 196 Date: 11/06/02 FREQ.

100.0000 33.3333 25.0000 20.0000 16.6667 14.2857 12.5000 11.1111 10.0000 9.0909 8.3333 7.6923 7.1429 6.6667 6.2500 5.8824 5.5556 5.2632 5.0000 4.7619 SPECTRAL VALUES --

tAcceleration of gravity used.

Time history matched to ape driss NO.

PERIOD REL. DISP.

1

.0100

.00324 2

.0300

.02929 3

.0400

.05230 4

.0500

.08217 5

.0600

.11916 6

.0700

.16350 7

.0800

.21567 8

.0900

.28296 9

.1000

.36189 10

.1100

.42719 11

.1200

.53023 12

.1300

.59286 13

.1400

.74944 14

.1500

.95714 15

.1600 1.22277 16

.1700 1.37815 17

.1800 1.48491 18

.1900 1.75720 19

.2000 2.19533 20

.2100 2.58632 981.001 interpretation DAMPING RATIO.

REL. VEL.

PSU.REL.VEL.

ABS. ACC.

.04659 2.03517 1.30348

.42323 6.13519 1.30994

.75929 8.21602 1.31575 1.19333 10.32620 1.32241 1.75055 12.47812 1.33154 2.44990 14.67598 1.34322 3.39500 16.93872 1.35718 3.85041 19.75402 1.40738 5.31972 22.73844 1.45864 7.11518 24.40102 1.42069 9.42262 27.76295 1.48118 12.14857 28.65415 1.41284 15.71104 33.63474 1.53836 22.71461 40.09249 1.71239 28.92574 48.01797 1.92701 29.86922 50.93645 1.92126 34.88205 51.83300 1.84782 41.31991 58.10957 1.96498 48.57540 68.96835 2.21413 57.10815 77.38247 2.36919

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 193 of 196 Date: 11/06/02 21

.2200 3.11335 60.67159 88.91719 2.59523 2.58865 4.5455 22

.2300 3.38051 67.27795 92.34930 2.58089 2.57168 4.3478 23

.2400 3.75947 78.92089 98.42281 2.63454 2.62661 4.1667 24

.2500 4.25960 88.93032 107.05540 2.75187 2.74271 4.0000 25

.2600 4.69605 92.48391 113.48510 2.80478 2.79561 3.8462 26

.2700 5.09995 98.88936 118.68130 2.82722 2.81533 3.7037 27

.2800 5.92268 105.48130 132.90460 3.04974 3.04013 3.5714 28

.2900 7.08256 129.52820 153.45190 3.39989 3.38911 3.4483 29

.3000 8.04715 143.60400 168.53910 3.61016 3.59824 3.3333 30

.3100 9.02608 151.56310 18.2.94360 3.79420 3.77978 3.2258 31

.3200 9.27798 139.86720 182.17280 3.66088 3.64623 3.1250 32

.3300 8.76538 134.08110 166.89240 3.25218 3.23917 3.0303 33

.3400 8.61399 138.88570 159.18620 3.01081 2.99873 2.9412 34

.3500 8.93408 151.73010 160.38430 2.94704 2.93498 2.8571 35

.3600 9.61659 156.73820 167.84110 2.99995 2.98612 2.7778 36

.3700 10.58843 157.51910 179.80830 3.12482 3.11257 2.7027 37

.3800 11.30116 165.45840 186.86130 3.16454 3.14954 2.6316 38

.3900 11.93637 179.61290 192.30360 3.17142 3.15816 2.5641 39

.4000 12.90272 182.98040 202.67540 3.25995 3.24528 2.5000 40

.4100 14.01802 180.83850 214.82390 3.37015 3.35591 2.4390 41

.4200 14.18628 175.78710 212.22620 3.24964 3.23639 2.3810 42

.4300 13.72272 167.49180 200.51720 2.99790 2.98672 2.3256 43

.4400 13.10733 161.50390 187.17220 2.73397 2.72458 2.2727 44

.4500 12.82593 158.99890 179.08380 2.55988 2.54891 2.2222 45

.4600 13.40888 162.67210 183.15320 2.55983 2.55016 2.1739 46

.4700 13.97853 167.39250 186.87180 2.55681 2.54658 2.1277 47

.4800 14.50521 175.20890 189.87270 2.54520 2.53357 2.0833 48

.4900 14.92303 178.01870 191.35550 2.51442 2.50124 2.0408 49

.5000 14.94276 175.73670 187.77630 2.41679 2.40537 2.0000 50

.5100 14.96067 173.59370 184.31500 2.32670 2.31474 1.9608 51

.5200 15.40997 176.91300 186.19940 2.30397 2.29343 1.9231 52

.5300 16.23315 185.54520 192.44510 2.33738 2.32564 1.8868 53

.5400 17.15452 195.76640 199.60190 2.37949 2.36746 1.8519 54

.5500 18.12130 206.74220 207.01730 2.42261 2.41076 1.8182 55

.5600 19.63611 219.32080 220.31660 2.53044 2.51982 1.7857 56

.5700 21.39442 231.43700 235.83360 2.66075 2.64997 1.7544 57

.5800 24.55191 240.40780 265.97270 2.94888 2.93711 1.7241 58

.6000 28.24199 286.58040 295.74940 3.16993 3.15707 1.6667 59

.6200 31.55596 317.74660 319.79340 3.31802 3.30361 1.6129 60

.6400 34.61403 329.56680 339.82250 3.41711 3.40082 1.5625 61

.6600 36.01749 312.34340 342.88570 3.34489 3.32749 1.5152 62

.6800 35.24006 290.59330 325.61740 3.07928 3.06697 1.4706 63

.7000 35.97029 288.04930 322.86860 2.96662 2.95419 1.4286 64

.7200 38.19618 293.81020 333.32460 2.97841 2.96514 1.3889 65

.7400 37.51666 289.23540 318.54610 2.76996 2.75709 1.3514 66

.7600 38.20645 297.65770 315.86610 2.67433 2.66195 1.3158 67

.7800 39.77415 304.03510 320.39530 2.64371 2.63089 1.2821 68

.8000 41.17450 309.11010 323.38380 2.60118 2.58904 1.2500 69

.8200 42.46626 313.46290 325.39440 2.55408 2.54160 1.2195 70

.8400 43.68412 317.26520 326.75650 2.50422 2.49147 1.1905

(~~~~~~~~

3/4\\A.

(

(7

(

Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 194 of 196 Date: 11/06/02 71

.8600 44.91529 320.47110 328.15240 2.45519 2.44393 1.1628 72

.8800 46.38626 323.11460 331.19710 2.42146 2.41054 1.1364 73

.9000 47.80081 325.42150 333.71260 2.38554 2.37488 1.1111 74

.9200 49.19193 327.54440 335.95870 2.34943 2.33889 1.0870 75

.9400 50.59373 329.70350 338.18060 2.31478 2.30426 1.0638 76

.9600 52.02686 332.02960 340.51500 2.28239 2.27183 1.0417 77

.9800 53.49854 334.52480 343.00130 2.25226 2.24172 1.0204 78 1.0000 54.97274 336.91190 345.40390 2.22266 2.21227 1.0000 79 1.0500 58.38807 340.72460 349.39340 2.14107 2.13126

.9524 80 1.1000 62.11906 347.84250 354.82330 2.07610 2.06600

.9091 81 1.1500 69.06382 380.37430 377.33980 2.11171 2.10158

.8696 82 1.2000 77.39297 414.09780 405.22870 2.17360 2.16287

.8333 83 1.2500 82.25122 403.02980 413.43970 2.12681 2.11842

.8000 84 1.3000 97.79282 402.36610 472.65420 2.34017 2.32869

.7692 85 1.3500 111.34890 459.59480 518.24150 2.47276 2.45872

.7407 86 1.4000 125.53840 528.09360 563.41490 2.58861 2.57757

.7143 87 1.4500 133.40600 577.95590 578.07920 2.56380 2.55347

.6897 88 1.5000 142.05640 610.86680 595.04440 2.55269 2.54079

.6667 89 1.5500 151.90200 638.34880 615.76030 2.55797 2.54443

.6452 90 1.6000 159.38910 646.71600 625.91940 2.51883 2.50559

.6250 91 1.6500 168.11860 634.75100 640.19420 2.49727 2.48507

.6061 92 1.7000 172.27960 644.20360 636.74380 2.41180 2.39898

.5882 93 1.7500 171.37720 633.29210 615.31130 2.26462 2.25200

.5714 94 1.8000 166.79820 610.51050 582.23550 2.08335 2.07175

.5556 95 1.8500 168.04660 590.96090 570.73940 1.98744 1.97595

.5405 96 1.9000 168.63110 610.34220 557.65300 1.89195 1.87984

.5263 97 1.9500 170.08080 627.62320 548.02520 1.81266 1.80002

.5128 98 2.0000 168.35460 633.75150 528.90170 1.70648 1.69378

.5000 99 2.0500 165.93540 627.13460 508.58680 1.59814 1.58899

.4878 100 2.1000 167.58340 609.59190 501.40840 1.53801 1.52927

.4762 101 2.1500 167.68280 584.81340 490.03830 1.46808 1.45983

.4651 102 2.2000 166.86510 556.22140 476.56560 1.39556 1.38743

.4545 103 2.2500 165.60350 526.21000 462.45210 1.32472 1.31642

.4444 104 2.3000 164.19690 495.94790 448.55630 1.25752 1.24911

.4348 105 2.3500 162.75310 466.36220 435.15230 1.19436 1.18600

.4255 106 2.4000 161.25040 465.75020 422.15260 1.13462 1.12660

.4167 107 2.5000 157.72590 461.77450 396.40830 1.02245 1.01558

.4000 108 2.6000 153.14970 453.61750 370.10310

.91820

.91172

.3846 109 2.7000 147.48190 442.06940 343.20600

.82114

.81415

.3704 110 2.8000 148.41260 429.19750 333.03710

.76940

.76181

.3571 111 2.9000 151.59370 416.46350 328.44530

.73311

.72540

.3448 112 3.0000 155.37330 404.14160 325.41320

.70257

.69474

.3333 113 3.1000 159.68120 391.62080 323.64720

.67663

.66868

.3226 114 3.2000 164.17640 377.96790 322.35960

.65326

.64521

.3125 115 3.3000 168.37420 362.36080 320.58370

.63039

.62221

.3030 116 3.4000 171.80870 347.86700 317.50170

.60640

.59811

.2941 117 3.5000 174.03610 342.34620 312.42900

.58011

.57173

.2857 118 3.6000 174.75380 351.99860 305.00300

.55102

.54264

.2778 119 3.7000 173.78030 359.94670 295.10650

.51911

.51084

.2703 120 3.8000 171.06990 365.72630 282.85890

.48479

.47676

.2632

121 122 123 124 125 126.

127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 3.9000 4.0000 4.1000 4.2000 4.3000 4.4000 4.5000 4.6000 4.7000 4.9000 4.9000 5.0000 5.1000 5.2000 5.4000 5.6000 5.8000 6.0000 6.2000 6.4000 6.6000 6.8000 7.0000 7.2000 7.4000 7.6000 7.8000 8.0000 8.5000 9.0000 9.5000 10.0000 166.72280 160.92660 156.48810 154.60190 150.39620 144.37750 147.44120 149.71550 145.41010 135.36530 139.96570 143.66060 145.62800 146.19050 143.60700 139.81530 140.39800 140.55660 140.94020 140.68240 148.96680 157.10400 159.66520 158.98670 163.89800 164.65210 161.83370 156.26420 140.46410 133.68110 119.54790 104.95790 369.07580 369.94000 368.40200 364.64610 359.04010 351.94680 343.75310 334.82060 325.55170 316.20020 307.01640 298.20010 289.89900 282.20670 268.83910 258.15750 249.92410 243.74250 239.17730 235.82830 233.35530 231.48850 230.02440 228.81640 227.76460 226.79870 225.88080 224.98460 222.77620 220.61510 218.55140 216.63920 2.5 SEC. 268.60260 252.78290 239.81560 231.28380 219.75980 206.17070 205.86680 204.49800 194.39120 177.19280 179.47560 180.52930 179.41330 176.64270 167.09440 156.87240 152.09430 147.19050 142.83120 138.11470 141.81600 145.16380 143.31510 138.74210 139.16240 136.12370 130.36300 122.72960 103.83080 93.32703 79.06756 65.94698 5.317 986.626 3.794 646.716

.44875

.41182

.37786

.35612

.33081

.30329

.29450

.28620

.26634

.23774

.23666

.23311

.22648

.21886

.19989

.18079

.16922

.15820

.14836

.13950

.13844

.13754

.13189

.12424

.12129

.11554

.10776

.09888

.07917

.06732

.05409

.04397

.44112

.40476

.37463

.35270

.32733

.30011

.29301

.28474

.26490

.23644

.23460

.23125

.22532

.21757

.19819

.17942

.16796

.15712

.14755

.13822

.13762

.13673

.13113

.12342

.12045

.11472

.10705

.09826

.07824

.06642

.05331

.04224 Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 195 of 196 Date: 11/06/02

.2564

.2500

.2439

.2381

.2326

.2273

.2222

.2174

.2128

.2083

.2041

.2000

.1961

.1923

.1852

.1786

.1724

.1667

.1613

.1563

.1515

.1471

.1429

.1389

.1351

.1316

.1282

.1250

.1176

.1111

.1053

.1000 VALUES IN PERIOD RANGE.1 TO AREA OF ACC.

RESPONSE SPECTRUM

=

AREA OF VEL.

RESPONSE SPECTRUM MAX.

ACCELERATION RESPONSE VALUE =

MAX.

VELOCITY RESPONSE VALUE =

1******

OPTION 6

COMPUTE MOTION IN NEW SUBLAYERS EARTHQUAKE -m78setl.acc SOIL DEPOSIT -

Idriss interpretation LAYER OUTCR.

WITHIN WITHIN WITHIN WITHIN WITHIN DEPTH FT

.0 3.0 6.0 10.0 15.0 20.0 MAX.

ACC.

G 1.30238 1.30042 1.29307 1.27178 1.21633 1.11340 TIME SEC 12.23 12.23 12.23 12.22 12.22 12.22 MEAN SQ.

FR.

C/SEC 1.57 1.57 1.56 1.53 1.45 1.33 ACC.

RATIO QUIET ZONE

.032

.032

.032

.032

.034

.037 TH SAVED ACC.

RECORD 820 0

0 0

0 0

(

(

(I Calc Number: GEO.HBIP.02.06 Rev Number: 0 Sheet Number: 196 of 196 Date: 11/06/02 WITHIN 25.0 1.06406 12.22 1.28

.038 0

WITHIN 30.0 1.03401 13.20 1.21

.039 0

WITHIN 35.0 1.01464 13.20 1.17

.040 0

WITHIN 40.0

.98905 13.19 1.13

.041 0

WITHIN 45.0

.95400 13.19 1.09

.042 0

WITHIN 50.0

.97016 12.32 1.09

.041 0

WITHIN 55.0

.97524 12.32 1.09

.041 0

WITHIN 60.0

.97691 12.32 1.09

.041 0

WITHIN 67.5

.97278 12.32 1.08

.041 0

WITHIN 75.0

.96068 12.31 1.07

.041 0

WITHIN 82.5

.93971 12.31 1.06

.042 0

WITHIN 90.0

.90967 12.31 1.05

.043 0

WITHIN 100.0

.87952 12.31 1.05

.044 0

WITHIN 111.0

.83811 12.31 1.05

.046 0

WITHIN 123.0

.78376 12.30 1.07

.049 0

WITHIN 135.0

.72617 12.29 1.10

.052 0

WITHIN 150.0

.68979 12.28 1.11

.054 0

WITHIN 163.0

.81477 13.39 1.36

.044 0

WITHIN 176.0

.95303 13.38 1.76

.036 0

WITHIN 189.0 1.05166 13.36 2.04

.031 0

WITHIN 202.0 1.08762 13.35 2.18

.028 0

WITHIN 215.0 1.08162 10.74 2.26

.026 0

WITHIN 230.0 1.07762 10.73 2.21

.025 0

WITHIN 245.0 1.01561 10.72 2.13

.026 0

WITHIN 260.0

.94807 10.71 2.10

.027 0

WITHIN 280.0

.89577 10.70 2.05

.028 0

WITHIN 300.0

.83075 10.72 1.96

.029 0

WITHIN 320.0

.77896 11.02 1.94

.030 0

WITHIN 340.0

.88032 11.00 2.19

.025 0

WITHIN 360.0

.95581 10.99 2.57

.022 0

WITHIN 380.0 1.01875 10.63 2.85

.019 0

WITHIN 400.0 1.13496 10.61 3.04

.016 0

WITHIN 425.0 1.20688 10.59 3.08

.014 0

WITHIN 450.0 1.29138 10.57 3.18

.012 0

WITHIN 475.0 1.26698 10.56 3.26

.011 0

WITHIN 500.0 1.22885 10.55 3.45

.010 0

WITHIN 525.0 1.15961 10.53 3.41

.010 0

WITHIN 550.0 1.12298 10.52 3.48

.010 0

WITHIN 575.0 1.14992 10.51 3.72

.009 0

WITHIN 600.0 1.22566 10.49 4.01

.008 0