NL-12-166, Reply to Request for Additional Information Regarding the License Renewal Application

From kanterella
(Redirected from ML12340A154)
Jump to navigation Jump to search

Reply to Request for Additional Information Regarding the License Renewal Application
ML12340A154
Person / Time
Site: Indian Point  
(DPR-026, DPR-064)
Issue date: 11/20/2012
From: Dacimo F
Entergy Nuclear Northeast
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NL-12-166
Download: ML12340A154 (9)


Text

%- Entergy Entergy Nuclear Northeast Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, NY 10511-0249 Tel (914) 254-2055 Fred Dacimo Vice President Operations License Renewal NL-12-166 November 20, 2012 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001

SUBJECT:

REFERENCE:

Reply to Request for Additional Information Regarding the License Renewal Application Indian Point Nuclear Generating Unit Nos. 2 & 3 Docket Nos. 50-247 and 50-286 License Nos. DPR-26 and DPR-64

1. NRC letter, "Request for Additional Information for the Review of the Indian Point Nuclear Generating Units 2 and 3, License Renewal Application, SET 2012-03" dated October 16, 2012

Dear Sir or Madam:

Entergy Nuclear Operations, Inc is providing the additional information requested in Reference 1 pertaining to NRC review of the License Renewal Application (LRA) for Indian Point 2 and Indian Point 3. Proprietary and Non-Proprietary versions of the reply are provided in Attachments 1 and 2, respectively. Attachment 3 provides the background for the response.

Attachments 1 and 3 include information deemed proprietary by an entity that is providing support to Entergy on this RAI response. As such, in Attachment 4, a 10 CFR 2.390 affidavit has been executed by the owner of the information.

There are no new regulatory commitments in this submittal.

If you have any questions, or require additional information, please contact Mr. Robert Walpole at 914-254-6710.

I declare under penalty of perjury that the foregoing is true and correct. Executed on

/-*2-710-1 2-Sincerely, FRD/rw

Docket Nos. 50-247 & 50-286 NL-12-166 Page 2 of 2

Attachment:

1.

Reply to NRC Request for Additional Information Regarding the License Renewal Application (Proprietary Reply)

2.

Reply to NRC Request for Additional Information Regarding the License Renewal Application (Non-Proprietary Reply)

3.

Westinghouse Proprietary Letter LTR-RIDA-12-197

4.

Application for Withholding Proprietary Information from Public Disclosure cc:

Mr. William Dean, Regional Administrator, NRC Region I Mr. Sherwin E. Turk, NRC Office of General Counsel, Special Counsel Mr. Dave Wrona, NRC Branch Chief, Engineering Review Branch I Mr. John Daily, NRC Sr. Project Manager, Division of License Renewal Mr. Douglas Pickett, NRR Senior Project Manager Ms. Bridget Frymire, New York State Department of Public Service NRC Resident Inspector's Office Mr. Francis J. Murray, Jr., President and CEO NYSERDA

ATTACHMENT 2 TO NL-12-166 REPLY TO NRC REQUEST FOR ADDITIONAL INFORMATION REGARDING THE LICENSE RENEWAL APPLICATION (Non-Proprietary Reply)

ENTERGY NUCLEAR OPERATIONS, INC.

INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 & 3 DOCKET NOS. 50-247 AND 50-286

NL-12-166 Page 1 of 6 INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 AND 3 LICENSE RENEWAL APPLICATION (LRA)

REQUESTS FOR ADDITIONAL INFORMATION (RAI)

RAI 16

Entergy Nuclear Operations, Inc. (Entergy)'s response to Applicant/Licensee Action Item 3 in the Reactor Vessel Internal (RVI) Inspection Plan (Reference 1), indicates that the current Indian Point Unit 2 (IP2) guide tube support pins (split pins) were installed in 1995 and are fabricated from X750 Rev. B material, which has improved resistance to stress corrosion cracking (SCC). Entergy's response further states that it plans to begin preliminary IP2 split pin replacement engineering and walkdowns in 2014 and replace the split pins in 2016. However, no basis was given for these dates. The response to request for additional information (RAI) 8 (Reference 2) indicates, in part, that no inspections are planned for the split pins during the period of extended operation, except that the replacement cold-worked Type 316 pins could potentially be inspected if determined to be necessary based on operating experience. Based on the above, the applicant apparently does not plan any inspections of the currently installed IP2 split pins.

Requested Information:

1.

Justify the proposed date for replacement of the IP2 split pins, based on predicted degradation of the split pins, and considering that no inspections will be performed on the currently-installed pins prior to replacement.

2.

If (a) the proposed replacement date (2016) cannot be justified without performing inspections; or (b) the currently-installed IP2 split pins are not replaced by the proposed date, provide the date when inspections would need to commence, and the periodicity of these inspections to ensure the intended function(s) of the split pins will be maintained until replacement.

3.

Describe the inspection methods to be used for any inspections proposed.

Response to RAI 16

1. The current IP2 split pins were installed in 1995 as a replacement for the original X-750 split pins which exhibited stress corrosion cracking (SCC) of one pin. The replacement split pins were designed, fabricated and installed in accordance with the requirements of Westinghouse Specification [Westinghouse Proprietary Information] and EPRI NP-7032.

These design, fabrication and installation improvements over the previous generation of split pins resulted in lower susceptibility to SCC by lowering the residual stresses, reducing the stress concentration effects, improving surface condition and increasing the material's resistance to stress corrosion cracking (SCC). The following summarizes the improvements made to the replacement pins as well as the operating experience of other Revision B, X-750 split pins:

NL-12-166 Page 2 of 6 a) The design improvements included the following.

Split Pin Threads - [Westinghouse Proprietary Information] no radius specification except as per the ANSI requirements for 0.625-11 UNC-2A. The thread engagement on the nut is the same for both the original and the replacement pins.

Split Pin Shank - [Westinghouse Proprietary Information].

[Westinghouse Proprietary Information]. This change, combined with the slightly smaller shank diameter, reduced the fillet stress [Westinghouse Proprietary Information].

Leaves - [Westinghouse Proprietary Information].

b) The material improvements to resist SCC included the following.

The support pin material was procured to a newer Westinghouse material specification, [Westinghouse Proprietary Information], than for the reference plant pin

[Westinghouse Proprietary Information] material specification. The newer specification incorporates all of the requirements in the Rev. B specification and addresses additional EPRI recommendations provided in EPRI report N-7032.

The material certification package indicates that the X-750 material was produced to the HTH condition, which is consistent with the heat treat requirements of

[Westinghouse Proprietary Information]. The HTH condition is a higher temperature (i.e. 1975 OF - 2050 OF) heat treatment designed to provide X-750 with improved SCC resistance over earlier heat treatments. A review of the Certified Material Test Reports (CMTRs) confirmed that the solution and precipitation hardening heat treatments meet both specifications. Mechanical, chemical and rising load test requirements were also met based on a review of the CMTRs.

From these evaluations, the material procured for the Indian Point Unit 2 support pins meets the requirements of both material specifications [Westinghouse Proprietary Information] as well as the improvements provided in EPRI N-7032.

c) Review of operating experience.

A review of the Operating Experience (OE) of the Alloy X-750 Revision B material was also performed to establish the likelihood that IP2 could experience cracking prior to the planned replacement date of 2016.

An analysis was performed to normalize the number of effective full power hours of fourteen plants to the same stress and operating temperature to allow for comparison between IP2 and the other plants with the same Revision B, split pin material.

Of these plants, twelve had cracking and separation at the pin shanks (either at the bottom of the shank or near the bottom of the threads) and two had pins with cracked and broken leaves. Therefore, the normalization was separated into these two groups due to the different operating time normalization method.

The operating times were normalized to the Indian Point Unit 2 operating conditions by both temperature and preload stress. The cracking susceptibility (Arrhenius)

NL-1 2-166 Page 3 of 6 equation was used to perform this normalization by multiplying each reference plant support pin operating Effective Full Power Hours (EFPH) by the ratio of this equation derived at the Indian Point Unit 2 conditions to that of each operating plant:

t ocex Q

-a IRTI?]

where, t = operating time to crack initiation

[Westinghouse Proprietary Information]

R = universal gas constant = 0.001986 kcal/(gmole OK)

T = absolute temperature in OK a = stress due to preload plus temperature (for the shank region)

[Westinghouse Proprietary Information]

For the ranges for Q and a, [Westinghouse Proprietary Information] were found to be most conservative to minimize the operating times normalized to Indian Point Unit 2 conditions. The exponent for the stress is typically closer to 4.0, however, since the shank stress is reduced by the reduced installation torque and typically lower temperature for Indian Point Unit 2, the value of [Westinghouse Proprietary Information] was used to minimize the benefit gained by the lower stress.

Pin Shank The shank stress, a,, is derived as a function of temperature. This is added to the initial preload stress. The stress as a function of temperature is based on the relative thermal expansion between the Inconel X-750 and Type 304 stainless materials, and the stiffness of the pin shank and surrounding guide tube flange.

o, - &E -

o a 2 )AT E

eb b

where,

/I = bottom flange thickness between pin shoulder and nut

/b = pin shank length from shoulder to thread engagement al and a2 = coefficients of thermal expansion for Type 304 and X-750 respectively AT = temperature change from room temperature to core exit normal operating temperature K = combined axial stiffness of bottom flange and nut Kb = pin shank axial stiffness E = X-750 elastic modulus The installation preload stress is derived using the minimum torque coefficient for two reasons. First, this maximizes the preload force which minimizes the effect of the added temperature stress when ratioed since the Indian Point Unit 2 operating core

NL-12-166 Page 4 of 6 exit temperature is typically less than for the reference plants. Secondly, it is likely that the pins that crack and fracture first, which are the ones used for the reference operating times, would have the highest stress. Thus, it is assumed that these pins had a higher preload. [Westinghouse Proprietary Information].

For each reference plant, the operating times were derived by summing operating intervals which occurred at different core exit temperatures.

The Indian Point core exit temperature was derived from the cycle-specific vessel outlet temperatures from cycle 13 when the pins were installed in 1995 until the proposed removal in 2016. A weighted average based on the effective full power days (EFPD) of each cycle times the temperatures was used for the measured temperatures up through cycle 18 (2008), and then from 2008 until 2016, four more cycles of 680 EFPD based on the highest EFPD per cycle is used times a bounding temperature of 5970F. This averaging resu!ts in a vessel outlet temperature of 594.90F. To convert to core exit temperature, an additional [Westinghouse Proprietary Information] based on Westinghouse derived core exit and vessel outlet temperatures for Indian Point Unit 2 is added to give [Westinghouse Proprietary Information]. To provide additional margin, the temperature is increased two more degrees to

[Westinghouse Proprietary Information].

Based on the above methodology and operating temperature, the following normalized operating times to failure of the support pin shanks result.

No. of Shank EFPH Normalized to Plant Fractures Indian Point Unit 2 A*

1 276,100 A

2 299,500 B

6 305,700 C

2 317,400 D

1 242,200 E

2 301,200 F*

1 349,500 F

4 356,500 G

4 376,800 H

5 241,700 K

2 277,300 L

1 270,400 N

1 307,000 O

5 232,900

  • Fractured during operation The average and 2a standard deviation range from this distribution are:

Average = 296,700 EFPH 2a range = 199,700 to 393,600 EFPH The above statistics are derived using the number of fractured shanks as listed. If based on the number of plants with no weighting by the number of fractures per plant,

NL-12-166 Page 5 of 6 the average is essentially the same at 296,600 EFPH, but with a slightly smaller 2C standard deviation, so the above derivation is slightly bounding.

Pin Leaves As previously mentioned, two plants had only fractures of the pin leaves. These were plants J and M.

To minimize the stress reduction due to the lower pinching interference of the Indian Point Unit 2 pins, the minimum interference is assumed for the reference plants and the maximum interference is assumed for the Indian Point Unit 2 pins. As shown above, this resulted in the same diametrical interference of [Westinghouse Proprietary Information]. Therefore, the reference plant operating times are normalized using only the effect of temperature. In reality, it is very likely that less interference preload exists. For this derivation, the resulting operating times normalized to Indian Point Unit 2 are:

No. of Shank EFPH Normalized to Plant Fractures Indian Point Unit 2 J

5 232,700 M

2 252,100 This gives an average time of 238,200 EFPH. Due to the small number of fractures, no standard deviation was derived.

Comparison to Indian Point Unit 2 Operating Time The above normalized operating times indicate that the probability of split pin cracking at IP2 due to SCC is extremely low based on the 152,000 EFPH estimated for IP2 between 1995 and the currently scheduled replacement date of March 2016. The lowest number of normalized EFPH before cracking was observed at other plants with Revision B split pin material was 232,700 EFPH which is significantly more than the estimated number of EFPH for IP2.

Conclusion Based on the results of the above review, it is concluded that the current IP2, X-750 Revision B split pins are acceptable for continued service through the current planned replacement date of 2016. The likelihood of pin cracking prior to 2016 resulting from SCC is low considering the low residual and preload stresses, the improved material's resistance to SCC and the OE of other Revision B split pins. It should be further noted that split pins are not core support structures and although failure of a split pin could result is a loose part it would not be expected to adversely affect the ability of the vessel internals to withstand a design basis transient.

2. a) As discussed above, the current IP2 split pins are acceptable for continued service through the proposed replacement date of 2016 given the design improvements, the improved material resistance to SCC and the operating experience of other plants with Revision B material split pins. Therefore, no split pin inspections are required prior to the 2016 replacement date.

NL-12-166 Page 6 of 6 b) The IP2 split pins are scheduled to be replaced during the 2016 refueling outage. If the replacement is not implemented as currently scheduled, Entergy will provide the NRC staff with a detailed inspection plan, including inspection methods, inspection coverage and inspection frequency no later than March 2015.

3. Since no inspections are planned, no details are provided in this response. However, if the replacement is not implemented during the March 2016 refueling outage, Entergy will provide the NRC staff with the inspection methods no later than March 2015.

References

1. Indian Point Energy Center Revised Reactor Vessel Internals Inspection Plan Compliant with MRP-227-A. Attachment 2 to Entergy Letter NL-12-037, Letter from Fred Dacimo to NRC dated February 17, 2012,

Subject:

License Renewal Application -Revised Reactor Vessel Internals Program and Inspection Plan Compliant with MRP-227 -A, Indian Point Nuclear Generating, Units 2 and 3 Docket Nos. 50-247 and 50-286-License Nos. DPR-26 and DPR-64 (ADAMS Accession No. ML12060A312).

2. Letter from Fred Dacimo to NRC dated June 14, 2012,

Subject:

Reply to Request for Additional Information Regarding the License Renewal Application Indian Point Nuclear Generating Unit Nos. 2 &3 Docket Nos. 50-247 and 50-286 License Nos. DPR-26 and DPR-64 (NL-12-089) (ADAMS Accession No. ML12184A037).