ML112370110
ML112370110 | |
Person / Time | |
---|---|
Site: | Browns Ferry |
Issue date: | 08/24/2011 |
From: | NRC/RGN-II |
To: | |
References | |
Download: ML112370110 (88) | |
Text
ES-401 Site-Specific RO Written Examination Form ES-401-7 Cover Sheet U.S. Nuclear Regulatory Commission Site-Specific RO Written Examination Applicant Information Name:
Date: Facility/Unit:
Region: I El Il El Ill El IV El Reactor Type: W El CE El BW El GE El Start Time: Finish Time:
Instructions Use the answer sheets provided to document your answers. Staple this cover sheet on top of the answer sheets. To pass the examination, you must achieve a final grade of at least 80.00 percent. Examination papers will be collected 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> after the examination begins.
Applicant Certification All work done on this examination is my own. I have neither given nor received aid.
Applicants Signature Results Examination Value Points Applicants Score Points Applicants Grade Percent
1.
Unit I was operating at 100% power when APRM 1 failed upscale.
Subsequently, the IA Recirc Pump tripped and the following conditions currently exist:
- Reactor power: 65%
- APRM I has NOT been bypassed Which ONE of the following completes the statements below?
The OPRM TRIP ENABLED annunciator (1-9-5A, Window 30) _(1)_ in alarm.
If Cell #28 in OPRM 3 subsequently exceeds its trip setpoint, an automatic reactor scram signal _(2)_ occur.
A. (1)is (2) will B. (I)is (2) will NOT C. (1) is NOT (2) will D. (1)is NOT (2) will NOT
2.
Unit 1 was operating at 100% power when a total loss of offsite power occurred (all three units).
- Diesel generators A, C, 3A and 3B started and tied to their respective boards.
- Only the A3 EECW pump is currently running.
Which ONE of the following completes the statements below in accordance with 0-AOI-57-IA, Loss of Offsite Power (161 and 500 KV)/Station Blackout?
Secure any Diesel Generator prior to (1) of operation without cooling water.
The second EECW Pump that should be started is the (2) Pump.
A. (1) eight minutes (2)B3 B. (1) eight minutes (2)C3 C. (1)ten minutes (2) B3 D. (1)ten minutes (2)C3
3.
A complete loss of power to Battery Board #3, Panel 11 has occurred.
Which ONE of the following describes how this affects the Unit 2 annunciator power supply to Panel 9-9 Cabinet 1?
A. No affect; the Unit 2 Panel 9-9 Cabinet I 48VDC power supply remains the same.
B. The Unit 2 Panel 9-9 Cabinet 1 48VDC power supply is now from Battery Board #1, Panel 11.
C. The Unit 2 Panel 9-9 Cabinet I 48VDC power supply is now from Battery Board #2, Panel 11.
D. The Unit 2 Panel 9-9 Cabinet 1 48VDC power supply to the annunciators is de-energized.
4.
Unit 1 is operating at 25% power with Auxiliary steam loads on Main Steam.
The following annunciator is alarming:
- TURBINE TRIP TIMER INITIATED (1-9-8A, Window 1)
The turbine has NOT yet tripped and turbine first stage pressure is 143 psig.
Which ONE of the following completes the statements below?
TURB CV FAST CLOSURE TURB SV CLOSURE SCRAM/RPT TRIP LOGIC BYPASS (1-9-5B, Window 16) is_(1)_.
Bypass valve capacity is _(2)_ to preclude a high reactor pressure SCRAM after the turbine trips.
A. (1)NOT in alarm (2) sufficient B. (1)NOT in alarm (2) NOT sufficient C. (1) in alarm (2) sufficient D. (1)in alarm (2) NOT sufficient
5.
Unit 2 was operating at 100% power when a scram occurred.
Which ONE of the following predicts the FINAL recirc pump speed, including the reason that the recirc pumps go to this speed?
Assume no manual operator action is taken after the reactor scram.
A. 28%;
mitigates the level shrink from the scram B. 28%;
prevent overheating of the recirc pumps or jet pump cavitation C. 75%;
mitigates the level shrink from the scram D. 75%;
prevent overheating of the recirc pumps or jet pump cavitation
6.
The Unit I Control Room is being abandoned in accordance with 1-AOl-I 00-2, Control Room Abandonment. ALL IMMEDIATE Operator Actions have just been completed.
Which ONE of the following completes the statements below?
UNTIL control is established at the Backup Control Panel, Reactor Pressure will be controlled by the (1).
BEFORE any Backup Control Panel transfers are performed, the reactor pressure value as indicated on Panel 1-25-32, for Reactor Pressure B, instrument 1 -P1-3-79 _(2)_ a valid indication.
A. (1) SRVs in Safety Mode (2) is NOT B. (1) Turbine Bypass Valves (2) is C. (1) SRVs in Safety Mode (2) is D. (1) Turbine Bypass Valves (2) is NOT
7.
Unit 3 is operating at 100% with the Unit I Spare RBCCW pump disassembled for maintenance.
One Unit 3 RBCCW pump trips and cannot be restarted.
Which ONE of the following completes the statements below?
The 3-FCV-070-48, RBCCW Sectionalizing Valve, will auto-close when the _(1 )_.
An IMMEDIATE manual reactor scram (2)_ in accordance with 3-AOI-70-1, Loss of RBCCW?
A. (1) supply header pressure reaches 57 psig.
(2)is required B. (1) suction header temperature reaches 95 deg.
(2) is required.
C. (1) supply header pressure reaches 57 psig.
(2) is NOT required D. (1) suction header temperature reaches 95 deg.
(2) is NOT required
8.
Unit 3 is operating at 100% power with all systems in their normal standby lineup.
Which ONE of the following describes how the HPCI standby lineup is affected following a loss of control air, in accordance with 3-AOI-32-2, Loss of Control Air?
A. 3-FCV-73-6A and 3-FCV-73-6B, HPCI STEAM LINE CNDS INBD & OUTBD DRAIN VLVs, fail CLOSED.
B. 3-FCV-73-17A and 3-FCV-73-17B, HPCI HOTWELL PUMP INBD & OUTBD CRW DISCH VLVs, fail OPEN.
C. 3-FCV-073-05, HPCI STEAM LINE STM TRAP BYP VLV, fails CLOSED.
D. 3-FCV-073-08, HPCI TURB EXH COND POT LCV, fails OPEN
9.
Unit I is in Mode 4. A loss of shutdown cooling has occurred.
The crew has placed RWCU in service in accordance with 1 -AOl-74-1, Loss of Shutdown Cooling, with two demineralizers in service.
Which ONE of the following completes the statements below?
The reason why 1-AOl-74-1 directs maximizing RWCU blowdown flow is to The maximum allowed flow with two-pump operation in accordance with 1-01-69, RWCU System is A. maintain reactor coolant temperature < 200 °F; 320 gpm B. establish natural circulation; 320 gpm C. maintain reactor coolant temperature < 200 °F; 200 gpm D. establish natural circulation; 200 gpm
10.
A core reload is in progress on Unit I and is almost complete in accordance with 0-GOl-100-3C, Fuel Movement Operation During Refueling. A fuel assembly is being lowered into the core.
Subsequently the following conditions occur:
- SRM PERIOD (1-9-5A, Window 20) alarms
- Rising count rate observed on all SRMs
- REFUELING ZONE EXHAUST RADIATION HIGH (1-9-3A, Window 34) alarms Which ONE of the following completes the statements below?
The main fuel grapple hoist downward motion _(1 )_ automatically blocked due to these conditions.
The CONTROL ROD WITHDRAWAL BLOCK annunciator (1-9-5A Window 7) _(2)_
in alarm.
A. (1)isNOT (2)is B. (1)1sNOT (2) is NOT C. (1)is (2)is D. (1)is (2) is NOT
11.
A station blackout has occurred on Unit 3 and the following containment conditions currently exist:
- Drywell pressure: 28 psig
- Drywell temperature: 250 °F and rising
- Torus pressure: 25 psig
- Torus level: 16ft Which ONE of the following completes the statements below?
Drywell sprays _(1 )_ at this time.
A subsequent condition that requires IMMEDIATE emergency depressurization in accordance with 3-EOI-2, Primary Containment Control, is (2)_.
[REFERENCE PROVIDED]
A. are allowed the ACTION REQUIRED region of Curve 8, RPV Saturation Temp, is entered.
B. are allowed the ACTION REQUIRED region of Curve 6, Press Suppr Press, is entered.
C. are not allowed the ACTION REQUIRED region of Curve 8, RPV Saturation Temp, is entered.
D. are not allowed the ACTION REQUIRED region of Curve 6, Press Suppr Press, is entered.
12.
Unit I was operating at 100% power when a main turbine trip occurred, an ATWS exists. The following annunciators alarmed after the turbine tripped:
- . REACTOR PRESS HIGH (1-9-5A, Window 1)
- MAIN STEAM RELIEF VALVE OPEN (1-9-3C, Window 25)
The Unit Operator observes that two MSRVs are cycling.
Which ONE of the following completes the following statement in accordance with 1-EOI-1 ,RPV Control RC/P leg?
Manually open _(1 )_ using _(2).
A. (1) The Turbine bypass valves to lower reactor pressure until no MSRV5 are cycling (2) 1-EOI Appendix-IIH, Alternate RPV Pressure Control systems Main Condenser.
B. (1) MSRVs until RPV pressure drops to the pressure at which all Turbine bypass valves are fully open (2) 1 -EOI Appendix-i 1 A, Alternate RPV Pressure Control systems MSRVs C. (1) The Turbine bypass valves to lower reactor pressure until no MSRVs are cycling (2) 1-EOI Appendix-i IA, Alternate RPV Pressure Control systems MSRVs D. (1) MSRVs until RPV pressure drops to the pressure at which all Turbine bypass valves are fully open (2) 1-EOI Appendix-IIH, Alternate RPV Pressure Control systems Main Condenser.
13.
A LOCA has occurred on Unit I and the following conditions currently exist:
- Narrow Range Torus Level: (-)1
- Suppression Pool Temperature: 1900 F
- Torus Pressure: 20 psig
- RPV Pressure: 900 psig Which ONE of the following identifies the answer to the following decision block and the subsequent required action in accordance with EOl-2, Primary Containment Control, SPIT leg?
SPIT_B YES L
[REFERENCE PROVIDED]
A. NO; lower reactor pressure and maintain it at 700 psig B. NO; emergency depressurization is required C. YES; rapidly depressurize the reactor to the main condenser D. YES; operate all available loops in torus cooling
14.
Unit 3 was operating at 100% power with all drywell coolers in operation:
A LOCA and partial loss of AC power simultaneously occur and the following conditions currently exist:
- Core Spray has received an auto initiation signal The crew is currently implementing the following step in EOI-2, Primary Containment Control:
Which ONE of the following completes the statements below?
The temperature value listed in step DWIT-2 is _(1 )_.
The number of drywell coolers that are operating 1 minute after the LOCA and partial loss of AC power is (2)_.
[ASSUME NO drywell coolers are manually started.]
[See Diagram on next page]
A. (1)280°F (2) four B. (1)280°F (2) six C. (1)160°F (2) four D. (1)160°F (2) six
L 15.
Which ONE of the following completes the statements below?
The low torus water level entry condition value in 1-EOl-2, Primary Containment Control, is the _(1 )_.
A system in 1-EOI Appendix 18, Suppression Pool Water Inventory Removal and Makeup, that will provide the HIGHEST make-up flow rate to the torus is _(2)_.
A. (1) Tech Spec 3.6.2.2, Suppression Pool Water Level LCD value (2) HPCI B. (1) alarm setpoint value for SUPPR CHAMBER WATER LEVEL ABNORMAL (1-9-3B, Window 15)
(2) HPCI C. (1) Tech Spec 3.6.2.2, Suppression Pool Water Level LCD value (2) RCIC D. (1) alarm setpoint value for SUPPR CHAMBER WATER LEVEL ABNORMAL (1-9-3B, Window 15)
(2) RCIC
16.
While implementing 1 -EOl-1, RPV Control, the Unit Supervisor (US) reaches the following override step:
V WHILE EXECUTING THE FOLLOWING STEPS:
!! THEN WATER LVL DIP LW_____
QE IKKLIT AES Thf ADS TIMER HAS INfl9ATtX)
Which ONE of the following completes the statements below?
The RPV water level listed in this step is (1).
The reason for inhibiting ADS at this value is that an auto ADS actuation _(2)_.
A. (1)(-)162 (2) imposes a severe thermal transient on the RPV B. (1) ()162; (2) provides positive reactivity C. (1) ()120 (2) provides positive reactivity D. (1)(-)120 (2) imposes a severe thermal transient on the RPV
17.
Unit I was at 100% power.
The following conditions currently exist:
- REACTOR CHANNEL A(B) AUTO SCRAM (1-9-5B, Windows I & 2): alarming
- Reactor pressure: 1000 psig
- All 8 RPS lights at Panel 1-9-5 are illuminated
- Reactor level: (-) 26 and slowly lowering Which ONE of the following completes the statements below?
The current status of the ATWS AUTO INITIATE annunciator (1 4A, Window 10) is
_( I )_.
The procedure required to insert control rods given the above conditions is (2)_.
Note: 1-EOI Appendix-I A, Removal and Replacement of RPS Scram Solenoid Fuses 1-EOI Appendix-IF, Manual Scram A. (1) in alarm (2) I-EOl Appendix-IA B. (I) in alarm (2) I-EOl Appendix-1F C. (I) NOT in alarm (2) 1-EOI Appendix-IA D. (1)NOT in alarm (2) 1-EOI Appendix-IF
18.
A General Emergency has been declared on Unit 1. The control room crew is assisting the Radiation Protection Staff to perform EPIP-1 3, Dose Assessment.
The following conditions currently exist:
- Wind Direction: 225°
- Release is due to a damaged portion of the Turbine Building, elevation 617 Which ONE of the following completes the statements below?
The plume direction is towards the _(1 )_.
The release is required to be categorized as (2)_.
A. (1) Northeast (2) elevated B. (1)Southwest (2) elevated C. (1) Northeast (2) ground D. (1)Southwest (2) ground
19.
Which ONE of the following identifies a task that is performed outside the Main Control Room in accordance with O-SSI-16, Control Building Fire EL 593 Through EL 617?
B. Bypass groupi isolations.
C. Close RFPT discharge valves.
D. Align RHR in suppression pool cooling mode
20.
Which ONE of the following completes both statements in accordance with 0-GOI-300-4, Switchyard Operations?
A _(1 )_ MVAR maximum outgoing limit applies to all three units for both 500-kV and 161-kV offsite power source qualification.
If the outgoing MVAR limit is exceeded for a unit and is not corrected within _(2)_,
the TOp must immediately inform BEN that both offsite power sources are disqualified for the unit that is exceeding the limit.
(1) (2)
A. 300 5 minutes B. 150 5 minutes C. 300 15 minutes D. 150 15 minutes
21.
Unit 2 was operating at 100% when the Unit Operator (UO) noted main condenser vacuum degrading on the Hotwell Temperature and Pressure Recorder 2-XR-2-2.
The UO depressed the Recirc Mid-Power Runback Pushbutton..
Which ONE of the following completes the statements below?
Reactor Recirc Pump speeds will lower until total steam flow is less than (1 )_.
The Reactor Feed Pumps will trip if vacuum degrades to (2)_.
(1) (2)
A 90% 10Hg B 785% 10Hg C 90% 7 Hg D. 78.5% 7 Hg
22.
Unit 2 has been operating in Mode I for one year.
The crew has entered 2-AOI-64-1, Drywell Pressure and/or Temperature High, or Excessive Leakage Into Drywell.
Which ONE of the following completes the statements below?
A _(1 )_ will result in rising Drywell pressure and/or temperature.
An actual leakage value that exceeds the Tech Spec 3.4.4, Operational Leakage, limit is an Unidentified Leakage _(2)_.
A. (1) leak from the Drywell Equipment Drain Sump Cooler (2) increase of 3 gpm within the previous 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> B. (1) leak from the Drywell Equipment Drain Sump Cooler (2) rate at 4 gpm C. (1) packing leak from 2-FCV-74-48, SHUTDOWN COOLING INBD SUCT ISOL (2) rate at 4 gpm D. (1) packing leak from 2-FCV-74-48, SHUTDOWN COOLING INBD SUCT ISOL (2) increase of 3 gpm within the previous 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />
23.
A startup is being performed on Unit 3 and all IRMs are on Range 8.
Which ONE of the following completes the statements below?
3-Tl-64-1 62, Suppression Pool Bulk Temperature, at Panel 3-9-3 is identified as a post accident monitoring instrument by a/an _(l )_.
3-TI-64-1 62 indicating _(2)_ requires entering an action statement in Tech Spec 3.6.2.1, Suppression Pool Average Temperature.
A. (1) orange label (2)103°F while RCIC is operating for a surveillance test B. (1) black label (2) 96°F with no testing in progress C. (1) orange label (2) 96°F with no testing in progress D. (1)black label (2) 103°F while RCIC is operating for a surveillance test
24.
Unit 2 is starting up with reactor pressure at 750 psig.
The 2A CRD Pump trips.
CRD ACCUM Press LOW/LEVEL HIGH (2-9-5A, Window 29) is in alarm CRD Charging Water Header Pressure: 1000 psig and slowly lowering Four Accumulator lights are illuminated on the full core display.
Which ONE of the following describes the required operator sequence of actions in accordance with 2-AOI-85-3, CRD System Failure?
A. Manually scram and immediately place the mode switch to shutdown; then place 1 B CRD Pump in service B. Immediately attempt to place I B CRD Pump in service; do not manually scram C. Immediately attempt to restart 2A CRD Pump; do not manually scram D. Manually scram and immediately place the mode switch to shutdown and then attempt to restart 2A CRD Pump
25.
Which ONE of the following completes the statements below?
A VALID annunciator that requires entry into 3-EOI-3, Secondary Containment Control is(1)_.
One radiation detector/monitor that triggers this annunciator is (2)_.
A. (1) RX BLDG AREA RADIATION HIGH (3-9-3A, Window 22)
(2) Rx Zone HVAC Radiation Monitor 142 B. (1) RX BLDG AREA RADIATION HIGH (3-9-3A, Window 22);
(2) area radiation monitor on the 565 elevation of the Reactor Bldg C. (1) RX BLDG, TURB BLDG, RF ZONE EXH RADIATION HIGH (3-9-3A, Window 4)
(2) Rx Zone HVAC Radiation Monitor 142 D. (1) RX BLDG, TURB BLDG, RE ZONE EXH RADIATION HIGH (3-9-3A, Window 4)
(2) area radiation monitor on the 565 elevation of the Reactor Bldg
26.
Which ONE of the following choices completes the following statements in accordance with the Updated Final Safety Analysis Report?
The reason that the main steam vault is equipped with blowout panels is to
_(1)_ following a main steam line rupture between the outboard isolation valve and the secondary containment wall.
Following a main steam line rupture between the outboard isolation valve and the secondary containment wall, the main steam vault blowout panels will relieve the steam and the steam would flow to the (2).
A. (1) ensure the steam release is routed via a pathway monitored for radioactivity; (2) Refuel Floor B. (1) ensure the steam release is routed via a pathway monitored for radioactivity; (2) Turbine Building C. (1) prevent overpressurization of the Reactor Building; (2) Refuel Floor D. (1) prevent overpressurization of the Reactor Building; (2) Turbine Building
27.
Which ONE of the following completes the statements below?
Primary Containment hydrogen concentration above _(1 )_ is an entry condition for 1 -EOl-2, Primary Containment Control.
The method used to control hydrogen and oxygen concentration in accordance with 1-EOl-2, is to inject the _(2)_ in to containment.
A. (1)4%
(2) A Nitrogen Storage Tank B. (1)4%
(2) B Nitrogen Storage Tank C. (1)2.4%
(2) A Nitrogen Storage Tank D. (1)2.4%
(2) B Nitrogen Storage Tank
28.
Current conditions on Unit 2:
- Reactor power is at 100%.
- 480V Shutdown Board 2B is de-energized
- 480 V RMOV Board 2A is de-energized Which ONE of the following predicts how the Unit 2 Low Pressure Coolant Injection (LPCI) system is affected if a large break LOCA occurred and reactor pressure lowers to 120 psig?
A. Loop 1 and Loop 2 will inject.
B. Loop I will inject and Loop 2 will NOT inject.
C. Loop 1 and Loop 2 will NOT inject.
D. Loop 1 will NOT inject and Loop 2 will inject.
29.
Current conditions on Unit 1:
- Reactor is in Mode 3.
- 1A Recirculation Pump is running.
- The operator is placing RHR Loop I in Shutdown Cooling in accordance with 1-01-74, Section 8.12.1, Initiation / Operation of RHR Loop I in Shutdown Cooling.
Which ONE of the following completes the statements below?
IF the operator places the IA RHR Pump control switch to START, AND performs NO further actions, flow indication on I -Fl-74-50, RHR SYS I FLOW, will _(l )_ AND flow indications on Jet Pumps I through 10 (Panel 1-9-4) will (2)_.
A. (1)rise (2) rise B. (1)rise (2) remain the same C. (1) remain at zero (2) remain the same D. (1) remain at zero (2) rise
30.
On Unit 1, HPCI has automatically started following a valid low water level initiation signal and is currently injecting to the RPV.
The following alarm is received while HPCI is operating:
Which ONE of the following completes the statements below?
The required operator action in accordance with the alarm response procedure, is to
_( I )_.
SUBSEQUENTLY a complete loss of control oil pressure occurs, the final position of 1-FCV-73-18, HPCI Turbine Stop Valve and I-FCV-73-19, HPCI Turbine Control Valve are _(2).
Assume the initiation signal remains present.
A. (1) start the Auxiliary Oil Pump (2) open B. (I) raise and maintain turbine speed above 2,400 RPM.
(2) closed C. (I) start the Auxiliary Oil Pump.
(2) closed D. (I) raise and maintain turbine speed above 2,400 RPM.
(2) open
31.
Unit I is starting up and the crew is performing 1-SR-3.5.1 .7, HPCI Main and Booster Pump Set Developed Head and Flow Rate Test at Rated Reactor Pressure.
The following conditions currently exist:
- HPCI is operating with its flow controller in AUTO set at 5300 gpm
- Unit Operator (UO) is throttling 1-FCV-73-35, HPCI Pump CST Test Valve, to establish the discharge pressure required by the surveillance.
Which ONE of the following completes the statements below?
If the Unit Operator fully closes I -FCV-73-35, then the 1 -FCV-73-30, HPCI Pump Mm Flow valve will _(1)_.
HPCI Turbine speed will _(2)_.
A. (1)auto open (2) rise B. (1)NOTautoopen (2) rise C. (1)auto open (2) lower D. (1) NOT auto open (2) lower
32.
Current conditions on Unit 2:
- All power has been lost to B 4KV Shutdown Board.
- A reactor scram has occurred due to high drywell pressure.
- Reactor pressure is 85 psig.
Which ONE of the following describes the response of the Core Spray system and the action(s) that must be taken in accordance with 2-01-75, Core Spray System?
A. Core Spray pumps A, C and D will auto start Loop I Inboard Injection Valve, 2-FCV-75-25 must manually be throttled locally.
B. Core Spray pumps A, B and D will auto start Loop II Inboard Injection Valve, 2-FCV-75-53 must be throttled.
C. Core Spray pumps A and C will auto start Core Spray Pump D must be manually started and Loop II Inboard Injection Valve 2-FCV-75-53 must be throttled.
D. Core Spray pumps B and D will auto start Core Spray Pump A must be manually started and Loop I Inboard Injection Valve 2-FCV-75-25 must be manually throttled locally.
33.
Which ONE of the following choices completes the following statement for how the Jet Pump Flow Indications at Panel 9-4 are developed at the SLC injection sparger?
The SLC injection spargers (1)_ tube is used to obtain a pressure signal for
_(2).
A. (1) inner (2) all 20 jet pumps B. (1) inner (2) only 16 jet pumps C. (1)outer (2) all 20 jet pumps D. (1)outer (2) only 16 jet pumps
34.
Which ONE of the following completes both statements for the Unit I B RPS MG set?
The normal power supply feed to the Unit 1 B RPS MG set is via the _(l )_.
The alternate power supply feed to the I B RPS Bus is from the _(2)_.
A. (1)4KVSDB0ardC (2) Unit Preferred Transformer B. (1)4KVSDB0ardB (2) 480 V RMOV Board 1 B C. (I)4KVSDB0ardC (2) 480 V RMOV Board 1 B D. (1)4KVSDB0ardB (2) Unit Preferred Transformer
35.
A startup is in progress on Unit 1 with the following conditions:
- Reactor Power is 6%
- RPV Pressure 750 psig
- IRM D failed upscale and annunciator procedure actions are complete
- IRMA25onRange9
- lRMB400nRange9
- lRMC200nRange9
- lRME600nRange9
- lRMF300nRange9
- lRMG65onRange9
- lRMH700nRange8 Which ONE of the following predicts the plant response if the Unit Operator places IRM B to Range 8?
A. No rod block or scram signals exist.
B. A rod block and half scram exist.
C. ONLY a rod block exists (no half scram exists).
D. A full scram exists.
36.
A startup is in progress on Unit 1 in accordance with 1-GOI-1 00-IA, Unit Startup.
The following conditions currently exist:
(3
- lRMA35onRange8
- lRMB400nRange8
- lRMC600nRange7
- IRMD300nRange8
- lRME300nRange8
- lRMF5OonRange7
- lRMG45onRange8
- lRMH4OonRange8 Which ONE of the following completes the statements below?
The required position of the SRM5 A, B, and C at this point in the startup is fully
_( I )_.
The CONTROL ROD WITHDRAWAL BLOCK (1-9-5A, Window 7) annunciator is
_(2)_.
A. (1)inserted (2) in alarm B. (1)withdrawn (2) in alarm C. (1) inserted (2) NOT in alarm D. (1)withdrawn (2) NOT in alarm
3T A reactor startup is in progress on Unit 1 with the following conditions:
- All SRMs are reading between 100 and 130 cps
- All SRMs are fully inserted
- All lRMs are on Range 2 and reading 3040
- Unit operator selects SRM D i gr,i t Fad ) S Which ONE of the following completes the statement below if the operator attempts to withdraw SRM D?
SRM D _(1 )_ withdraw and a Control Rod Withdrawal Block _(2)_ occur.
A. (1)will (2) will B. (1)will (2) will NOT C. (1)will NOT (2) will D. (1)wiII NOT (2) will NOT
38.
Which ONE of the following completes the statements below?
There are a total of _(1 )_ LPRM detectors in the core.
LPRMs are located such that _(2).
A. 185; every core location or its symmetrical counterpart in another quadrant is monitored.
B. 172; every core location or its symmetrical counterpart in another quadrant is monitored.
C. 185; the A detectors are at the top of the core and the D detectors are at the bottom of the core.
D. 172; the A detectors are at the top of the core and the D detectors are at the bottom of the core.
39.
Unit 2 was operating at 100% power when RCIC received a valid auto initiation signal.
RCIC STEAM LINE FLOW EXCESSIVE (2-9-3B, Window 21) annunciator was SUBSEQUENTLY received.
The following indications currently exist:
- 2-FCV-71-2, RCIC Steam Line Inboard Isolation Valve GREEN light is illuminated
- 2-FCV-71-3, RCIC Steam Line Outboard Isolation Valve GREEN light is illuminated
- 2-FCV-71 -8, Steam Supply Valve RED light is illuminated
- 2-FCV-71 -34, RCIC Pump Mm Flow Valve GREEN light is illuminated
- 2-FCV-1-55, Main Steam Line Inboard Drain Valve GREEN light is illuminated
- 2-FCV-1 -56, Main Steam Line Outboard Drain Valve GREEN light is illuminated
- RPV level is currently at -60 inches.
Which ONE of the following describes the automatic valve alignment?
ASSUME NO operator action has been taken A. All valves are properly aligned.
B. 2-FCV-71-8 is misaligned.
C. 2-FCV-71-34 is misaligned.
D. 2-FCV-1-55 and -56 are misaligned.
40.
Unit 2 is operating at 100% power.
SR-3.5.3.3, RCIC System Rated Flow at Normal Operating Pressure, is in progress with RCIC operating to the CST.
A loss of 250 VDC RMOV Board 2B occurs.
Five minutes later, the following annunciator is received:
- RCIC STEAM LINE LEAK DETECTION TEMP HIGH (2-9-3D, Window 10)
Which ONE of the following completes the statements below if a RCIC isolation SUBSEQUENTLY occurs?
_(1 )_ will auto close.
2- EOl-3, Secondary Containment Control is_(2)_ to be entered.
Note 2-FCV-71-2, RCIC Steam Line Inboard Isolation Valve 2-FCV-71-3, RCIC Steam Line Outboard Isolation Valve A. (1)Onlythe7l-2 (2) NOT required B. (1)Both 71-2 and 71-3 (2) NOT required C. (1) Only the 71-2 (2) required D. (1)Both 71-2 and 71-3 (2) required
41.
Unit 3 was operating at 100% power with HPCI tagged out for maintenance.
The following timeline of events subsequently occurred:
- T-0: Loss of Offsite Power on Unit 3; 3A and 3D EDGs failed to start
- T÷5 minutes: Drywell pressure reached 2.45 psig slowly rising
- T÷7 minutes: Level lowered to (+) 2 inches
- T+1 0 minutes: Level is currently at (-) 135 inches and slowly lowering with RCIC injecting Which ONE of the following completes the statements below?
ADS will actuate _(1 )_ after level reached the low low low level setpoint.
The ADS valves will _(2) if the operator depresses the XS-1 -159/161, Hi DW Pressure / RX LO Level Logic A/B Reset pushbuttons AFTER ADS has actuated.
A. (1)360 seconds (2) remain open B. (1)95seconds (2) remain open C. (1)360 seconds (2) close D. (1)95 seconds (2) close
42.
Unit 3 was operating at 100% power when an MSIV closure and ATWS occurred.
Reactor Pressure peaked at 1150 psig (maximum).
Which ONE of the following completes the statements below?
One of the MSRVs that initially auto cycled _(1 )_ an ADS Valve.
With Reactor Power at 15% _(2)_ MSRVs are required to control Reactor Pressure (1) (2)
A. was 2 B. was 3 C. was NOT 2 D. was NOT 3
43.
The following LOCA conditions exist on Unit 1:
- Drywell pressure is 2.2 psig
- Reactor water level is (-) 40 inches
- Main Steam Tunnel temperature is 180°F
- RCIC Pump Room temperature is 175 °F
- HPCI Pump room temperature is 175 °F Which ONE of the following identifies whether PCIS Groups 4, 5, and 8 have received an automatic isolation signal?
A. Groups 4, 5, and 8 all have automatically isolated.
B. Only Groups 4 and 5 have automatically isolated.
C. Only Group 8 has automatically isolated.
D. Only Groups 5 and 8 have automatically isolated.
44.
Unit 3 is operating at 100% power when the following conditions are observed:
- MAIN STEAM RELIEF VALVE OPEN (3-9-3C, Window 25) Alarms
- GENERATOR LOAD recorder, 3-XR-57-57 indicates MWs lowering
- Suppression Pool temperature is 85°F and rising
- A fire is reported in the Unit 3 Diesel Generator Building; SSI entry is NOT req u i red Which ONE of the following describes the required actions to take in accordance with 3-AOl-i-i, Relief Valve Stuck Open?
A. Immediately initiate a load reduction to 90%, THEN cycle the affected relief valve control switch several times as required in an attempt to close the valve.
B. Immediately cycle the affected relief valve control switch several times and if the MSRV does not close, THEN initiate a load reduction to 90% power.
C. Immediately insert a scram, THEN cycle the affected relief valve control switch several times.
D. Immediately cycle the affected relief valve control switch several times and if the MSRV does not close, THEN Immediately initiate a scram.
45.
Unit 2 is operating at 100% power with the following alarms due to a failure of the Turbine 1st stage pressure transmitter:
- RFWCS INPUT FAILURE (2-9-6C, Window 14)
- MAIN STEAM LINE VS STEAM FLOW MISMATCH (2-9-SB, Window 24)
FWLC is currently in 3 element control.
SUBSEQUENTLY the A main steam line flow signal slowly fails to ZERO over a 10 minute period.
Which ONE of the following completes the statements below?
As the main steam line flow signal fails, Reactor Water Level will (1 )_.
The final status of the Feedwater Level Control System will be _(2)_ control.
A. (1) lower (2) single element B. (1)lower (2) three element C. (1) remain constant (2) single element D. (1) remain constant (2) three element
46.
Unit 3 is operating at 100% power with a small coolant leak in the drywell. Standby Gas Treatment (SGT) Train C was placed in service to vent the drywell. The following conditions currently exist:
- Drywell pressure has stabilized at 1.6 psig
- SGT C vent flow rate is 100 scfm SUBSEQUENTLY the normal feeder breaker to 3ED 4KV Shutdown Board trips open and the board cannot be re-energized.
Which ONE of the following completes the statements below?
Drywell pressure will (1 )_.
The A and B SGT5 _(2)_ immediately auto start.
A. (1) remain constant (2) will B. (1) remain constant (2) will NOT C. (1)rise (2) will D. (1)rise (2) will NOT
47.
A LOCA with significant fuel failure has occurred on Unit 3.
The A and B Standby Gas Treatment (SGT) trains have been used several times to vent the drywell.
The A SGT train was shutdown in accordance with 0-01-65, Standby Gas Treatment System.
Which ONE of the following completes the statements below?
The minimum temperature at which decay heat removal is required to be initiated due to iodine absorption in accordance with 0-01-65, Standby Gas Treatment System is
_( I )_
If the annunciator SGT TRAIN A UNAVAILABLE (3-9-3B, Window 11)
SUBSEQUENTLY alarms, the Unit 3 operator is required to contact _(2)_ to determine the cause.
A. (1) 150°F (2) Unit I Control Room B. (1) 150°F (2) Unit 2 Control Room C. (1)270°F (2) Unit I Control Room D. (1)270°F (2) Unit 2 Control Room
48.
Which ONE of the following completes the statements below for Unit 1?
The transformer that is part of a required offsite power circuit in accordance with Technical Specification 3.8.1, AC Sources-Operating is _(l)_.
The shutdown bus that normally feeds 4KV SD Board B is Shutdown Bus (2)_.
(1) (2)
A. USSTIA 1 B. USST1A 2 C. USSTIB 1 D. USST1B 2
49.
Which ONE of the following describes the normal and alternate power supplies to Battery Board 1, Panel 11?
A. Normal power is supplied by an inverter; alternate power is from the unit preferred transformer from 480 volt RMOV board I A, or the Unit 3 MMG set.
B. Normal power is supplied by an inverter; alternate power is from the unit preferred transformer from 480 volt RMOV board IA, or the Unit 2 MMG set.
C. Normal power is supplied by the unit preferred transformer; alternate power is from the Unit 3 MMG set.
D. Normal power is supplied by the unit preferred transformer; alternate power is from the Unit 2 MMG set.
50.
All three units are operating at 100% power with all battery chargers in normal operation.
Which ONE of the following completes both statements in accordance with 0-01-31 Control Bay and Off-Gas Treatment Building Air Conditioning System, Section 7.11, Shutdown of Battery and Board Room Exhaust Fans?
Battery Room ventilation is required to be in operation _(1 )_.
Obtain _(2)_ permission prior to shutting down the Battery Room Exhaust fan.
A. (1) in accordance with Tech Spec LCO 3.&4, DC Systems Operating (2) Electrical Maintenance B. (1) to prevent buildup of explosive hydrogen (2) Electrical Maintenance C. (1) in accordance with Tech Spec LCO 3.8.4, DC Systems Operating (2) Unit Supervisor D. (1) to prevent buildup of explosive hydrogen (2) Unit Supervisor
51.
Which ONE of the following completes the statements below?
The lube oil circulating pump (1)_ provide oil to the turbocharger bearing area.
If the 3A diesel generator lube oil circulating pump is lost, the 3A DIG _(2) be able to start and load.
A. (1)doesNOT (2) will B. (1)does NOT (2) will NOT C. (1)does (2) will D. (1)does (2) will NOT
52.
The following plant conditions exist:
- G Air Compressor is in service
- O-TCV-32-2945, Cooling System Heat Exchanger Bypass Valve, has failed such that the air compressor has lost its cooling Which ONE of the following completes the statement below?
In accordance with 0-01-32, Control Air System, the Compressor G trip setpoint for
_(1 )_ is _(2)_.
A. (1) air discharge temperature (2)120°F B. (1) lube oil temperature (2) 130°F C. (1) lube oil temperature (2)120°F D. (1) air discharge temperature (2) 130°F
53.
The Unit 2 crew is adjusting the RBCCW system flow in accordance with 2-01-70, RBCCW System, Section 6.5, RBCCW Flow Control.
During the evolution, the following annunciator alarms:
- RBCCW 2-FCV-70-48 CLOSED (2-9-4C, Window 19)
Which ONE of the following:
- 1) identifies the required method for adjusting RBCCW system flow in accordance with 2-01-70, Section 6.5 and
- 2) predicts another annunciator that will alarm as a result of the 2-FCV-70-48 closure?
A. (1) manually throttle the RBCCW HX 2A and 2B Outlet Valves, 2-ISV-70-607A and 2-ISV-70-607B locally (2) RBCCW PUMP SUCT HDR TEMP HIGH (2-9-4C, Window 5)
B. (1) manually throttle the RBCCW HX 2A and 28 Outlet Valves, 2-ISV-70-607A and 2-ISV-70-607B locally (2) RWCU NON-REGNERATIVE HX DISCH TEMP HIGH (2-9-4B, Window 17)
C. (1) manually adjust RBCCW HX A (B) temperature controller, 2-TIC-24-80 on Panel 25-1 96 (2) RBCCW PUMP SUCT HDR TEMP HIGH (2-9-4C, Window 5)
D. (1) manually adjust RBCCW HX A (B) temperature controller, 2-TIC-24-80 on Panel 25-1 96 (2) RWCU NON-REGNERATIVE HX DISCH TEMP HIGH (2-9-4B, Window 17)
54.
Unit I is at 80% power with the following plant conditions:
- I -FIC-85-1 1, CRD System Flow Controller, is in automatic.
- The handswitch for 1-HS-85-23, Drive Water Pressure Control Valve, has been throttled in the CLOSE direction for ONE second.
Which ONE of the following completes the statements below?
After conditions have stabilized, CRD Drive Water Header DP, as indicated on l-PDI-85-17A will _(1)_ and CRD Cooling Water Header Flow, as indicated on 1 -Fl-85-25A will (2)_.
(1) (2)
A. increase remain the same B. increase decrease C. decrease remain the same D. decrease decrease
55.
Unit 2 is operating at 100% power and the following alarm is received:
- CONTROL ROD DRIVE UNIT TEMP HIGH (2-9-5A, Window 17)
Which ONE of the following completes both statements below?
The set point for this alarm is _(1 )_.
One cause of this alarm is a leaking scram _(2)_ valve.
A. (1)250°F (2) inlet B. (1)350°F (2) inlet C. (1)250°F (2) outlet D. (1)350°F (2) outlet
56.
Which ONE of the following completes both statements below?
The function of 2-FCV-69-94, RWCU Appendix R Isolation Valve, is to mitigate the spurious opening of(1)_.
2-FCV-69-94 is located on the (2) of the RWCU Pumps.
A. (1) RWCU Inboard/Outboard Suction Isolation Valves 2-FCV-69-112 (2) suction side B. (1) RWCU Inboard/Outboard Suction Isolation Valves 2-FCV-69-1/2 (2) discharge side C. (1) RWCU Blowdown valve 2-FCV-69-15 (2) suction side D. (1) RWCU Blowdown valve 2-FCV-69-15 (2) discharge side
57.
Unit 3 plant conditions are as follows:
- Reactor Power is at 75%
- Traversing In-core Probe (TIP) scans are in progress
- B TIP Drive Control Unit Mode Switch (S-7) is in MANUAL A valid group 8 isolation signal is received.
Which ONE of the following predicts the FINAL status of the B TIP Purge Valve and Ball Valve?
Purge Valve Ball Valve A. Closed Open B. Open Closed C. Open Open D. Closed Closed
58.
Which ONE of the following completes both statements regarding the APRM and Voter power supply arrangement?
Each APRM chassis is powered from _(1 )_.
A. only one RPS bus B. a 0200 VDC High Voltage Power Supply (HVPS)
C. only one Quadruple Low Voltage Power Supply (QLVPS)
D. its associated 2 out of 4 voter chasis
59.
Unit I is operating at 100% power with the following conditions:
Surveillance in progress on 1-LIS-3-203A, Reactor Water Level Low RX VESSEL WTR LEVEL LOW HALF SCRAM (1-9-4A, Window 2) is in alarm Before the half scram is reset, I -LT-3-203C fails downscale.
Which ONE of the following predicts the status of the Group 3 PCIS valves?
A. RWCU remains in service B. ONLY 1-FCV-69-1, RWCU Inboard Isolation Valve, auto closes C. ONLY 1-FCV-69-2, RWCU Outboard Isolation Valve, auto closes D. BOTH 1-FCV-69-1 and 2, RWCU Inboard and Outboard Valves auto close
60.
Which ONE of the following completes both statements pertaining to the Drywell D/P Air Compressor?
The air compressor will auto start when TORUS pressure is _(1) DRYWELL pressure.
The air compressor will stop when TORUS pressure is _(2)_ DRYWELL pressure.
(1) (2)
A. 1.30 psid lower than 1.15 psid lower than B. 1.15 psid lower than 1.30 psid lower than C. 1.30 psid higher than 1.15 psid higher than D. 1.15 psid higher than 1.30 psid higher than
61.
A LOCA has occurred on Unit 2, Drywell and Torus Sprays are in service in accordance with the PC/P leg of EOl-2, Primary Containment Control, 2-EOl Appendix-I 7B, RHR System Operation Drywell Sprays, and 2-EOI-Appendix-l 7C, RHR System Operation Suppression Chamber Sprays.
After sprays were initiated, the following conditions are noted:
- Torus pressure: 1.5 psig and lowering
- Drywell pressure: 1.0 psig and lowering
- Suppression Pool Water Level: 17 ft Which ONE of the following completes both statements below?
A concern with the automatic operation of the Reactor-Building-to-Torus Vacuum Breakers is _(I )_.
When Suppression Pool Water Level cannot be maintained below _(2)_, 2-EOl-2 requires Drywell Sprays to be secured.
A. (1) ECCS Pump NPSH Limits (2) 19.0 ft B. (1) ECCS Pump NPSH Limits (2) 18.0 ft C. (I) Oxygen Concentration (2) 19.0 ft D. (1) Oxygen Concentration (2) 18.0 ft
62.
Unit I was operating at 100% power when the Main Hydrogen Seal Oil Pump tripped and seal oil pressure initially dropped to 105 psig.
Which ONE of the following completes both statements below?
The Seal Oil Vacuum Pump will (1).
Hydrogen Purity will (2)_.
A. (1)trip (2) lower B. (1)trip (2) remain unchanged C. (1)NOTtrip (2) lower D. (1)NOTtrip (2) remain unchanged
63.
Unit 2 is operating at 100% power:
- Master Level Controller in AUTO set at 33 inches
- 2A Reactor Feedwater Controller in AUTO
- 2B Reactor Feedwater Controller in AUTO
- 2C Reactor Feedwater Controller in MANUAL Operator depresses the Column Selector pushbutton, selects Column 3, and then depresses the Ramp Up Pushbutton on Reactor Feed Pump Turbine 2C.
Which ONE of the following completes both statements below?
Reactor Feed Pump Turbine 2C speed will _(1 )_.
Reactor Feed Pump Turbines 2A and 2B speed will (2)_.
[REFERENCE PROVIDED]
A. (1) rise (2) lower B. (1) lower (2) rise C. (1) remain the same (2) rise D. (1) remain the same (2) remain the same
64.
Which ONE of the following completes both statements below?
In a NORMAL standby lineup the FIRST CREV train that will auto start on a valid initiation signal is _(l)_.
IF CREV fails to initiate on a valid initiation signal the procedure(s) that contains the required steps to be used to start a CREV Fan is _(2)_.
NOTE: 0-01-31, Control Bay and Off-Gas Treatment Building Air Conditioning System 0-AOI-31-1, Control Bay Isolation (High Radiation)
A. (1)TrainA (2) ONLY 0-01-31 B. (1)TrainA (2) either 0-01-31 or 0-AOl-31-1 C. (1)TrainB (2) ONLY 0-01-31 D. (1)TrainB (2) either 0-01-31 or 0-A0I-31-1
65.
Which ONE of the following completes both statements regarding the design basis (DBA) LOCA analysis?
The DBA LOCA analysis is based on the double-ended break of one of the recirculation loops _(1 )_.
IF another break at the _(2)_ exists, THEN reactor water level will NOT be maintained above two-thirds core height, without injection.
A. (1) suction piping (2) jet pump inlet riser B. (1) suction piping (2) jet pump diffuser C. (1) ring header (2) jet pump inlet riser D. (1) ring header (2)jet pump diffuser
66.
Unit 2 is operating at 100% power.
An annunciator alarmed because one of its inputs had failed downscale, i.e.;
NOT a valid indication.
The invalid input was subsequently disabled in accordance with OPDP-4, Annunciator Disablement.
Which ONE of the following completes both statements below in accordance with OPDP-4?
The annunciator window is required to be flagged with a _(1 )_ magnetic border.
The associated ESOM5 narrative log entry shall include the (2).
A. (1)blue (2) method used to disable annunciator B. (1)blue (2) reactor power and generator output at the time the annunciator was disabled C. (1)white (2) method used to disable annunciator D. (1)white (2) reactor power and generator output at the time the annunciator was disabled
67.
Unit 2 turbine generator is operating as follows:
- GENERATOR LOAD RECORDER: 1000 MW.
- GENERATOR HYDROGEN PRESSURE, 2-Pl-35-17A: 60 psig and lowering at a rate of 15 psig per hour.
Which ONE of the following identifies the MAXIMUM time the generator can be operated without exceeding the limits of the Estimated Reactive Capability Curves?
(ASSUME NO operator action.)
[REFERENCE PROVIDED]
A. 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> B. 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> C. 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> D. 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />
68.
Unit 2 is in Mode 2 with single notch rod withdrawal in progress per 2-GOl-100-1A, Unit Startup and Power Operation.
When the Unit Operator withdrew the next rod, it moved from 00 to 04 and the following indications were observed:
- CHANNEL A PERIOD, 2X1-92-7/44A 25 seconds
- CHANNEL B PERIOD, 2Xl-92-7144B 25 seconds
- CHANNEL C PERIOD, 2X1-92-7144C 25 seconds
- CHANNEL D PERIOD, 2X1-92-7144D 25 seconds WHICH ONE of the following completes both statements below?
The required operator action in accordance with 2-GOl-1 00-IA, Unit Startup and Power Operation is to _(I)_.
In accordance with 2-AOl-85-7, Mispositioned Control Rod, the control rod _(2)_
considered mispositioned.
A. (1) make the reactor subcritical (2)is B. (I) make the reactor subcritical (2) is NOT C. (I) reinsert the last control rod pulled to obtain a stable period greater than 60 seconds (2) is D. (1) reinsert the last control rod pulled to obtain a stable period greater than 60 seconds (2) is NOT
69.
Which ONE of the following meets the requirements of a Complex Infrequently Performed Test or Evolution (CIPTE) per NPG-SPP-06.9.1, Conduct of Testing?
A. Switching Order to remove the West Point 500KV line in accordance with 0-GOI-300-4, Switchyard Manual.
B. 1-SR-3.5.1.7(COMP), HPCI Comprehensive Pump Test.
C. 0-SR-3.8.1.9(A) Diesel Generator A Emergency Unit I Load Acceptance Test.
D. I-SR-3.5.1 .6(RHR I) Quarterly RHR System Rated Flow Test Loop I.
70.
Unit 2 is critical in Mode 2 with a Reactor Coolant System heatup in progress.
Which ONE of the following completes both statements below?
The maximum heatup rate allowed by 2-SR-3.4.9.1(1), Reactor Heatup and Cooldown Rate Monitoring and Tech Spec 3.4.9 RCS Pressure and Temperature (PIT) Limits, is
_(1) °F in any one hour period.
The LOWEST level of permission/authorization required to perform 2-SR-3.4.9.1(1), is from the (2)_.
A. (1)90 (2) Unit Supervisor B. (1)90 (2) Shift Manager C. (1)100 (2) Unit Supervisor D. (1)100 (2) Shift Manager
71.
Unit 3 has entered the EOIs and immediate entry into a High Radiation Area by an Assistant Unit Operator (AUO) is required. NO RWP currently exists for this entry.
Which ONE of the following completes both statements below in accordance with RCI-9.1, Radiation Work Permits?
This High Radiation Area entry, without an RWP, must be authorized by the _(1)_.
A Radiation Protection individual _(2).
A. (1) Shift Manager (2) equipped with a dose rate monitoring device must escort the AUO.
B. (1) Radiation Protection Shift Supervisor (2) equipped with a dose rate monitoring device must escort the AUO.
C. (1) Shift Manager (2) escort is not required.
D. (1) Radiation Protection Shift Supervisor (2) escort is not required.
72.
Unit 3 initial drywell entry is in progress in accordance with 3-GOI-200-2, Primary Containment Initial Entry and Closeout.
The entry will be made by a team consisting of a Rad Protection Technician, a maintenance mechanic, laborer, and an Assistant Unit Operator (AUO). All of these personnel will inspect all accessible elevations in the drywell.
The following conditions currently exist:
- All control rods have been inserted
- Reactor Pressure is 50 psig
- The Mode Switch is in the Shutdown position Which ONE of the following completes both statements below?
The minimum required Oxygen concentration that allows entry without a Self Contained Breathing apparatus (SCBA) is at least _(1)_.
An additional member of _(2)_ is required to remain at the Personnel Airlock Door while the team is inspecting the drywell.
A. (1)20.8%
(2) Maintenance B. (1) 19.5%
(2) Maintenance C. (1)20.8%
(2) Operations D. (1) 19.5%
(2) Operations
73.
Which ONE of the following identifies a plant parameter value that is listed as an entry condition on 3-EOl-3, Secondary Containment Control, and will also cause an automatic Secondary Containment isolation signal?
A. Reactor Vessel Water Level at 0 B. Drywell Pressure at 3 psig C. Refueling Floor Exhaust Radiation at 50 mR/hr D. Reactor Zone Exhaust Radiation at 100 mR/hr
74.
Unit 2 is operating at 100% RTP and the following valid alarms are received:
- OG POST TRTMT RADIATION HIGH (2-9-4C, Window 33)
- OG POST TRTMT RADIATION HIGH HIGH, (2-9-4C, Window 34)
Which ONE of the following completes both statements below?
The current status of the Offgas System Isolation Valve, 2-FCV-66-28 with the above listed alarms is _(1).
SUBSEQUENTLY the OG POST TRTMT RADIATION HIHI-HI/INOP (2-9-4C, Window
- 35) is in alarm, the alarm is verified valid and the required operator action would be to reduce _(2)_.
A. (1) closed (2) power to maintain off-gas radiation within ODCM limits (Scram not required)
B. (1)closed (2) core flow to between 50-60% and manually scram the reactor if a scram has not already occurred C. (1)open (2) power to maintain off-gas radiation within ODCM limits (Scram not required)
D. (1)open (2) core flow to between 50-60% and manually scram the reactor if a scram has not already occurred
75.
Unit I has experienced an ATVVS and RPS cannot immediately be de-energized.
The US has dispatched an AUD to perform i-EOl Appendix-I B, Vent and Depressurize the Scram Pilot Air Header.
Which ONE of the following completes both statements below?
The AUO will perform I -EOl Appendix-i B (1 )_.
The AUO will vent the scram header at (2).
A. (1) at the CRD catwalk above Hydraulic Control Units (2) the pressure switch used for the SCRAM PILOT AIR HEADER PRESS LOW (I-9-5B, Window 28) annunciator.
B. (1) at the 565 elevation north east at the CRD station (2) one of the 3-way Alternate Rod Insertion (ARI) solenoid valves.
C. (I) at the 565 elevation north east at the CRD station (2) the pressure switch used for the SCRAM PILOT AIR HEADER PRESS LOW (i-9-5B, Window 28) annunciator.
D. (1) at the CRD catwalk above Hydraulic Control Units (2) one of the 3-way Alternate Rod Insertion (ARI) solenoid valves.
RO Exam Reference Packet
- Q#1 1: Curve 5 (DWSIL Curve: Unit 3) and Curve 8
- Q#13: Curve 3 (HCTL Curve: Unit 1)
- Q#63: 2-01-3, Illustration 2 (Only Page 1 of 4)
- Q#67: 2-01-47, Illustration 6 WI notes extracted; curve only (Generator Capability Curve)
- 11 Curve 5 (DWSIL Curve) and Curve 8 (RPV Saturation) Unit 3
- 13 Curve 3 (HCTL) Unit I
- 63 2-01-3 Illustration 2 page 1 of 4
- 67 2-01-47 Illustration 6 (Generator Capability Curve), with notes extracted.
0 0 CURVE 5 DW SPRAY INIT LIMIT 500 400 U
a w 300 200 100 0 10 20 30 40 50 60 DW PRESS (PSIG)
- CONSTANT ABOVE 60 PSIG
CD CURVE 8 RPV SATURATION TEMP 400 380 360 Co z
D 340 I
z 320 UI D
300 I-U) z 280 UI 260 z
a 240 UI 1-220 200 0 50 100 150 200 250 RPV PRESS (PSIG)
- CONSTANT ABOVE 250 PSIG
0 CURVE 3 HEAT CAPACITY TEMP LIMIT 2601 I I I I I o I - SAFE WHEN RX PRESS RPVPrs IS BELOW 90 PSIG 240 - I I I in I I Ii 220 w p3 I-
-J 21 0 I a
200 RpiIess.5O -
£1 a 190 D pv PresS. -
(I) 180 SAFE I
150 I V V 11.5 12 15 16 SUPPR PL LVL (FT)
ACTiON REQUIRED IF ABOVE CURVE FOR EXISTING RX PRESS
BFN Reactor Feedwater System 2-01-3 Unit 2 Rev. 0136 Page 180 of 216 Illustration 2 (Page 1 of 4)
RFPT Speed Control Panel Display Station MANUAL GOVERNOR CONTROL INDICATING LIGHT 0 0 0 NORM LOWER - - RAISE RFPT SPEED CONTROL 0 0 PUSH FOR MANUAL GOVERNOR PULL FOR FEEDWATER CONTROL SELECTED TAG ABOVE SCALE SELECTED VALUE INDICATOR SELECTED COLUMN AUTO /MANUAL RL÷ INDICATOR COLUMN 1 COLUMN 2 COLUMN 3 BAR GRAPH DISPLAY COLUMNS E + FIELDBUS ERROR BELOW SCALE INDICATOR pjiip u I A II VI I /L j* AUTO/MANUAL SELECTOR RAMP DO?N COLUMN SELECTOR Figure 2
If4flJ EARS LAG o i.
C F çJ 8
0 I
m Up rr C,,
0
§ 1I
KEYID fl iRING & 0 RESCORE I MULTiPLE ANSWER SCORING Pearson NCS Test Sheet Lc©©J L PRINTING OPTIONS:
( CORRECT ANSWER 0 MARKX 0 TOTAL ONL)
MARK ONLY ONE 1001W T F Form No. 95677 I A.C TF 51 A BØ.D E TF A B C
- E A B C 0 E Reorder Form No. 95677
2 0 B C 0 B 26 27 4: B :C
- E 52 A
- C D B 76 77 A B C. B 1-800-367-6627 Fax 1-507-451-4513
(
valuebridge. ncspearson. com 3 A,*C Q, E 53 A C D, £ 280 B C D E 78 A B C D E 4 A B
- D E 54
- B C 0 E 29 A B)*(0,i £ 79 B (C).D E 5 AC 0 B 55 A B C
- E ANSWER PERFORMANCE
6 A C D E 30 A B
- 0 E 56* B C D E 80 A B C D E KEY INFO.
- OF KEYS ASSESSMENT
% OF
31 ,A .C .0 B 81 ,A B, C D E iTEM TOTAL EA RNED 7 A, B,* 0 B 57 A (BCØ B COUNT SCORE
8 B C 0 E 32 A B C
- E 58 A B
- 0 E 82 A B C 0 F 00 = 100%
9 A ,B
- 0 B 33
- B ) B C 0 E 83 A B c b E aaa
10
- B C 0 E 34 A B
- 0 B 590B 60 A C 0 E 84 A B C V E DD rD cDD 35 AjC .0 E 85 A B, c(o E cc 0 cDD
11 A
- C 0 B 36 A B C
- E 61 A (, C
- E 86 A B C 0 E cDcD c
cc 12 A
- C 0 B 37* C DE 62 0 B C D B 87 A B C,)0 ac ca 13 A,0 C B 38 A
- C 0 E 630(B,)C D E 88 A B C 0 E c
14 A B C
- E 390 B QD,E 64 A
- C 0 E 89 A.B E 1
CD Copyright © 1994, 2001 NCS Pearson, Inc.
All rights reserved. Printed in U.S.A.
is*o C 65 A OC V E
16 A B C
- B E
40 A B
- 0 B 66
- B C V E 90 A B C D E 41 A, B C
- E 91 A B ,c, (D) *E IZO Et*c
17 4: B *D, 18 A B D E
E 42 A
- C D E 67 68 A
- B ,C, C
P E 0 £0 92 A B C C E IAJe4Z1 frl 43 A. BC* B 93 A B. () b,) E 19 *, C, D E 69 A B
- 0 E 44* B C D E 94 A B C 0 E
20 A BLD E 45 B)c CE 70 A B
- D B 95 A Q,0, £ 21 A B d
- E 71
- B C P E 46 A B C *IE 96 A B C D E
22 A B C
- E 470 B C, V E) 72 A B C
- B 97 A C V E 0,
23 A 73 A B ,C)* B
24 A
- C D B 48 A B
- 0 E 74 A B C
- B 98 A B C 0 E 0 C) 0.
00 49 4, C, 0 E 99 ,A, B C D C 25 A 0. £ 75 A BQ E 50 A B C
- E 100 A B C D E 4.-----
COMBINED NUMBER POINTS CORRECT EARNED
COMBINED L
PERCENT PERCENT CORRECT CORRECT
ROSTER LETTER NUMBER GRADE SCORE SCORE STUDENT ID NUMBER 1
RESCORE MARKING INSTRUCTIONS DacDcDa
()aDaDc:D I NAME O (E\STEa Ly Use a No. 2 Pencil SUBJECT
//0
/_ E?<Jfr A.c p B Fill oval completely ccc
Mark Reflex EIOD , DATE 00 forms by Pearson NCS MM956774 20
/ / / ao i A B 0 E Erase cleanly Ca) ID CD
/
RO E><ciM QUESTION KIA STATEMENTS ID -----
295001AA2.02 I 2 295003G2.I.23 I 3 295004AK1.02 I 4 295005AK2.UI I 5 295006AK3 06 1 6 295016AA1.08 I 7 295018AK1.01 I 8 295019AK2.179 9 295021AK3.04 1 10 295023AA105 I II ZSo?A- A2.OI 12 295025G2.4.47 I 13 295026EK2.06 I 14 295028EA1.03 I 15 295030EA2.01 I 16 295031EK3.0l I 17 295037G2.4.46 I 18 295038EK1.03 I 19 600000G2.4.34 I 20 700000AKI.02 I 21 295002AA1.08 I 22 2%O1OAA2Ott 29SOlOAA2.GI 23 295013G2.4.3 I 24 295022AKI.02 I 25 295033EK2.02 I 26 295035EK3.01 I 27 500000EKI.01 I 28 203000K6.01 I 29 205000A1.02 I 30 206000A2.15 I 31 206000A3.06 1 32 209001A4.05 I 33 211000K1.071 34 212000K2.0l 1 35 215003K3.01 I 36 215004K4.06 I 37 215004K5.03 I 38 215005K5.04 I 39 2-l-OOOA301 1- Zi7000A3.OI 40 217000A2.05 I 41 I8OOpAJ.o1I 42 218000G2.1.7 I 43 223002A406 I 44 239002G2.1.20 I 45 259002K102 I 46 261000K3.03 1 47 4GM--+ a6I000AJ.Q7
-Q0:Ot M I of 3
To X&kP QUESTION KIA STATEMENTS ID 48 262001K2.01 I 49 262002K4.01 I 50 263000K5.01 I 51 264000K6.03 I 52 300000K4.03 I 53 400000A1.0I 1 54 201001A3.04 I 55 201003A4.01 I 56 20400002,1.28 1 57 215001K1.05 I 58 215002K2.03 1 59 216000K3.02 I 60 223001K4.06 I 61 230000K5.07 I 62 245000K6.03 I 63 259001A1.01 I 64 290003A2,04-+ 2.9OOO3A2.0 65 290002K3.01 I 66 G2.I.182 67 02.1.253 68 G2.1.37 3 69 02.2.7 3 70 02.2.12 3 71 02.3.7 4 72 02.3.124 73 02.4.2 3 74 02.4.4 3 75 02.4.35 I 76 295004AA2.02 I 77 295006G2.4.41 I 78 79 02 102.4.30 1 80 29503 .4.6 1 8! 600000G2.4.
82 700000AA2.05 I 83 295009AA2.0l I 84 29501402.2.38 1 87 259002A2.06 I 88 eoøe--i 89 264000A2.03 I 90 40000002.4.11 1 91 OOA2.05-1 1JZGOOA2OS 92 20200102.2.44 1 93 214000A2.01 I 94 02.1.5 1 Thcayiunc 00, 2011 O:2OM z0 P3
RD QUESTION KIA STATEMENTS 99 02.4.5 I 100 G2.4.38 I go 3