Text

From:

Singal, Balwant Sent:

Thursday, April 14, 2011 3:37 PM To:

Harrison, Albon Cc:

plwalker@STPEGS.COM

Subject:

Relief Request RR-ENG-2 Request for Additional Information (TACs ME4514 and ME4515)

Attachments:

ME4514-RAI.docx Wayne:

Based the information provided for the subject application, the U.S. Nuclear Regulatory Commission (NRC) staff has determined that the additional information is needed for the NRC staff to complete its review. The request for additional information (RAI) is described in the attachment to this e-mail.

As discussed with Phil Walker, the schedule for this task is very tight and your response to this RAI is requested by April 30, 2011. If there are any questions, please contact me.

Thanks.

Balwant K. Singal Senior Project Manager (Comanche Peak and STP)