Letter Sequence RAI |
|---|
|
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request
- Acceptance...
Results
Other: DCL-16-023, Response to NRC Letter Dated February 2, 2016, Requests for Additional Information for the Review of the License Renewal Application - Set 39, ML100710113, ML100710114, ML101690321, ML101890832, ML101960644, ML110460718, ML13135A010, ML15037A540, ML15233A518, ML15243A582, ML15275A094, ML15275A130, ML16271A439
|
MONTHYEARML1007101142010-03-10010 March 2010 Task Order No. 002 Under Delivery Order No. NRC-03-10-070 Project stage: Other ML1007101132010-03-10010 March 2010 Task Order No. 002 Under Delivery Order No. NRC-03-10-070 Project stage: Other ML1013201872010-05-18018 May 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application Project stage: RAI ML1013806142010-05-24024 May 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC Nos. ME2896 and ME2897) - Scoping and Screening Methodology Project stage: RAI DCL-10-066, License Amendment Request 10-03, Damping Values for the Seismic Design and Analysis of the Reactor Vessel Integrated Head Assembly2010-06-14014 June 2010 License Amendment Request 10-03, Damping Values for the Seismic Design and Analysis of the Reactor Vessel Integrated Head Assembly Project stage: Request ML1015404192010-06-14014 June 2010 Letter Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC Nos. ME2896 and ME2897) - Aging Management Programs Project stage: RAI DCL-10-067, Response to License Renewal Application (LRA) Request for Additional Information & LRA Errata2010-06-18018 June 2010 Response to License Renewal Application (LRA) Request for Additional Information & LRA Errata Project stage: Request ML1016201872010-06-21021 June 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC Nos. ME2896 and ME2897) - Aging Management Programs Project stage: RAI ML1016901302010-06-29029 June 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC Nos. ME2896 and ME2897) - Aging Management Programs Project stage: RAI ML1017601042010-07-0606 July 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application Project stage: RAI DCL-10-073, Response to NRC Request for Additional Information on License Renewal Application2010-07-0707 July 2010 Response to NRC Request for Additional Information on License Renewal Application Project stage: Response to RAI ML1017602432010-07-14014 July 2010 RAI Related to the Review of the DCPP LRA - Aging Management Programs Project stage: RAI ML1018301312010-07-15015 July 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC Nos. ME2896 and ME2897) - Scoping and Screening and Aging Management Review Project stage: RAI ML1018908322010-07-16016 July 2010 Audit Report Regarding the Diablo Canyon Nuclear Power Plant License Renewal Application Scoping and Screening Methodology Project stage: Other DCL-10-077, Response to NRC Letter Dated June 21, 2010 Request for Additional Information (Set 5) for License Renewal Application2010-07-19019 July 2010 Response to NRC Letter Dated June 21, 2010 Request for Additional Information (Set 5) for License Renewal Application Project stage: Request ML1018700882010-07-19019 July 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC Nos. ME2896 and ME2897) - Aging Management Programs Project stage: RAI ML1018301442010-07-20020 July 2010 RAI Related to the Review of the DCPP LRA - Aging Management Programs and Aging Management Review Project stage: RAI ML1018802552010-07-20020 July 2010 RAI Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC Nos. ME2896 and ME2897) - Reactor Vessel Internals Project stage: RAI ML1019004702010-07-20020 July 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 & 2, LRA (Tac Nos. ME2896, and ME2897) - Scoping and Screening Project stage: RAI ML1018807352010-07-22022 July 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application - Aging Management Review and Aging Management Programs Project stage: RAI ML1018900212010-07-22022 July 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application - Aging Management Review and Time Limited Aging Analysis Project stage: RAI DCL-10-091, Response to NRC Letter Dated June 18, 2010, Request for Additional Information (High Energy Piping) for License Renewal Application2010-07-28028 July 2010 Response to NRC Letter Dated June 18, 2010, Request for Additional Information (High Energy Piping) for License Renewal Application Project stage: Request ML1020004882010-08-0303 August 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC Nos. ME2896 and ME2897) - Aging Management Review and Aging Management Programs Project stage: RAI ML1020402512010-08-0909 August 2010 RAI Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC Nos. ME2896 and ME2897) - Scoping and Screening and Aging Management Review Project stage: RAI ML1016903212010-08-11011 August 2010 Audit Report for Plant Aging Management Programs for DCPP, Units 1 and 2 Project stage: Other ML1019606442010-08-13013 August 2010 Safety Project Manager Change for the License Renewal Project for Diablo Canyon Nuclear Power Plant Project stage: Other DCL-2010-536, Submittal of National Marine Fisheries Service (NMFS) Marine Mammal and Marine Turtle Stranding Report for a Sea Turtle Discovered in the Diablo Canyon Intake Structure2010-08-25025 August 2010 Submittal of National Marine Fisheries Service (NMFS) Marine Mammal and Marine Turtle Stranding Report for a Sea Turtle Discovered in the Diablo Canyon Intake Structure Project stage: Request ML1021705242010-08-25025 August 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC Nos. ME2896 and ME2897) - Metal Fatigue Project stage: RAI ML1020107002010-08-26026 August 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC Nos. ME2896 and ME2897) - Time Limited Aging Analyses and Aging Management Programs Project stage: RAI ML1022402772010-08-26026 August 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC ME2896 and ME2897) - Aging Management Programs Project stage: RAI ML1022905422010-08-30030 August 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC Nos. ME2896 and ME2897) - Aging Management Review and Time Limited Aging Analyses Project stage: RAI DCL-10-113, Response to NRC Letter Dated August 3, 2010, Request for Additional Information (Set 16) for the License Renewal Application2010-08-30030 August 2010 Response to NRC Letter Dated August 3, 2010, Request for Additional Information (Set 16) for the License Renewal Application Project stage: Request ML1023607492010-09-0101 September 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC Nos. ME2896 and ME2897) - Aging Management Programs Project stage: RAI ML1024300272010-09-13013 September 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC Nos. Me 2869 and ME2897) - Scoping and Screening Project stage: RAI ML1024600502010-09-17017 September 2010 RAI Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC Nos. ME2896 & ME2897) Aging Management Programs Project stage: RAI ML1025202782010-09-17017 September 2010 RAI Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC Nos. ME2896 and ME2897) - Scoping and Screening Project stage: RAI DCL-10-121, Response to NRC Letter Dated August 25, 2010, Request for Additional Information (Set 19) for License Renewal Application2010-09-22022 September 2010 Response to NRC Letter Dated August 25, 2010, Request for Additional Information (Set 19) for License Renewal Application Project stage: Request ML1025102972010-09-23023 September 2010 RAI Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC Nos. ME2896 and ME2897) - Time Limited Aging Analyses Project stage: RAI DCL-10-120, Response to NRC Letter Dated August 26, 2010, Request for Additional Information (Set 17) for License Renewal Application2010-09-24024 September 2010 Response to NRC Letter Dated August 26, 2010, Request for Additional Information (Set 17) for License Renewal Application Project stage: Request ML1024601512010-09-28028 September 2010 Summary of Telephone Conference Call Held on 9/2/10 Between Us NRC and Pacific Gas and Electric Company Concerning the Response to RAIs Related to the Diablo Canyon Nuclear Power Plant Units 1 and 2 LRA Project stage: RAI ML1025202642010-09-29029 September 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application - Aging Management Review Project stage: RAI ML1026605412010-09-30030 September 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC Nos. ME2896 and ME2897) - Fire Protection Project stage: RAI DCL-10-126, Response to NRC Letter Dated September 1, 2010, Request for Additional Information(Set 22) for the Diablo Canyon License Renewal Application2010-09-30030 September 2010 Response to NRC Letter Dated September 1, 2010, Request for Additional Information(Set 22) for the Diablo Canyon License Renewal Application Project stage: Request ML1029806892010-11-0202 November 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC Nos. ME2896 and ME2897) - Time Limited Aging Analysis Project stage: RAI ML1029306302010-11-0303 November 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application - Aging Management Programs Project stage: RAI ML1034104342010-12-20020 December 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC ME2896 and ME2897) - Time Limited Aging Analysis Project stage: RAI ML1034810132010-12-20020 December 2010 Request for Additional Information Related to the Review of the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Application (TAC Nos. ME2896 and ME2897) - Aging Management Program and Time Limited Aging Analysis Project stage: RAI ML1035603212011-01-10010 January 2011 12/8/10 Summary of Telephone Conference Call Held Btw the USNRC and Pacific Gas and Electric Company Concerning Requests for Additional Information Response Related to the Diablo Canyon Nuclear Power Plant, Units 1 and 2, License Renewal Ap Project stage: RAI ML1034904172011-01-10010 January 2011 12/1/10 Summary of Telephone Conference Call Held Btw the USNRC and Pacific Gas and Electric Company Concerning Draft Request for Additional Information Related to the Diablo Canyon Nuclear Power Plant, Units 1 and 2, LRA Project stage: Draft RAI ML1034306232011-01-11011 January 2011 Summary of Telephone Conference Call Held Between NRC and PG&E Concerning Request for Additional Information Related Tot the Diablo Canyon Nuclear Power Plant, Units 1 and 2, LRA (TAC Nos. ME2896 & ME2897) Project stage: RAI 2010-07-07
[Table View] |
Text
c,\\.~P.R REGilt _
UNITED STATES
-t",
(:t~.. o~
NUCLEAR REGULATORY COMMISSION
- r g
WASHINGTON, D.C. 20555*0001 Ii;
~
~
~
-:-"'o?
....o~
February 7, 2011
LICENSEE:
Pacific Gas and Electric Company FACILITY:
Diablo Canyon Nuclear Power Plant, Units 1 and 2
SUBJECT:
SUMMARY
OF TELEPHONE CONFERENCE CALL HELD ON DECEMBER 14, 2010, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND PACIFIC GAS AND ELECTRIC COMPANY CONCERNING REQUESTS FOR ADDITIONAL INFORMATION RESPONSE RELATED TO THE DIABLO CANYON NUCLEAR POWER PLANT. UNITS 1 AND 2, LICENSE RENEWAL APPLICATION (TAC NUMBERS ME2896 AND ME2897)
The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of Pacific Gas and Electric Company (PG&E or the applicant) held a telephone conference call on December 14, 2010, to obtain clarification on PG&E's responses to the staff's requests for additional information (RAI) regarding the Diablo Canyon Nuclear Power Plant license renewal application.
By letters dated October 12, 15,27, November 3, and 8, 2010, PG&E sent the staff its responses to RAls regarding scoping and screening and TLAAs The staff reviewed the information contained therein, and requested a telephone conference call The telephone conference call was useful in clarifying PG&E's response. Enclosure 1 provides a listing of the participants. Enclosure 2 provides discussions on the RAI response for which the staff requested clarification.
The applicant had an opportunity to comment on this summary.
~
-~.
Nathaniel B. Ferrer, Project Manager Projects Branch 2 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-275 and 50-323
Enclosures:
As stated cc w/encls: Distribution via Listserv
TELEPHONE CONFERENCE CALL DIABLO CANYON NUCLEAR POWER PLANT, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION LIST OF PARTICIPANTS DECEMBER 14, 2010 PARTICIPANTS:
Nate Ferrer Bill Rogers Stan Gardocki Garry Armstrong John Tsao Carol Nove Terry Grebel Dan Gibbons Brandy Sizemore Kevin Braico Chris Beard David Gonzalez Miranda Tan Sid Bowern Greg Porter Larry Price Phillipe Soenen David Kunsemiller Stan Shepard AI Saunders Rye Davis AFFILIATIONS:
U.S. Nuclear Regulatory Commission (NRC)
NRC NRC NRC NRC NRC Pacific Gas and Electric Company (PG&E)
PG&E PG&E PG&E PG&E PG&E PG&E PG&E PG&E PG&E PG&E Strategic Teaming And Resource Sharing (STARS)
STARS STARS STARS ENCLOSURE 1
Diablo Canyon Nuclear Power Plant. Units 1 and 2 License Renewal Application Request for Additional Information Scoping/Screening and TLAA RAI2.1-1 In its supplemental response to request for additional information (RAI) 2.1-1, the applicant provided its Title 10 of the Code of Federal Regulations (10 CFR) 54.4(a)(2) evaluation for nonsafety-related, fluid-filled components in the vicinity of safety-related components in the turbine building.
Discussion:
The staff was not clear on whether nonsafety-related, fluid-filled components could affect the HVAC supply and exhaust ducts in the 480V switchgear rooms. The staff was also not sure whether nonsafety-related, fluid-filled components could affect the CRPS supply fans, controls, and instrumentation. The applicant agreed to supplement its response to RAI 2.1-1 to address the staff's concerns.
RAt 2.3-1 In its supplemental response to RAI 2.3-1, the applicant provided justification for not including non safety-related piping directly attached to safety-related solenoid-operated valves in the compressed air system. The applicant referenced Nuclear Energy Institute (NEI) 95-10, Appendix F, Section 5.2.3.1, as part of its justification.
Discussion:
The staff noted that NEI95-10, Appendix F, Section 5 applies to nonsafety-related structures and components (SCs) that are not directly attached to safety-related SCs; therefore, the staff was not clear why this section of NEI 95-10 applies to the nonsafety-related piping. The applicant agreed to supplement its response to RAI 2.3-1 to address the staff's concerns.
RAt 2.3-3 In its supplemental response to RAI 2.3-1, the applicant provided justification for not including nonsafety-related, fluid-filled components located in the fuel oil transfer pump vaults.
Discussion:
The staff could not determine, based on the applicant's justification, why the nonsafety-related, fluid-filled components would not affect the safety-related components located in the vaults.
The applicant agreed to supplement its response to RAI 2.3-1 to address the staffs concerns.
ENCLOSURE 2
- 2 RAI 2.3.3.7-1 In its supplemental response to RAI 2.3.3.7-1, the applicant provided justification for not including water traps in the compressed air system within the scope of license renewal.
Discussion:
The staff was not clear on whether a complete failure of the water traps could affect safety-related components that are located in the vicinity of the traps. The applicant agreed to supplement its response to RAI 2.3.3.7-1 to address the staff's concerns.
RAI 2.3.3.14-1 In its supplemental response to RAI 2.3.3.14-1, the applicant provided justification for why the diesel air start unloader line was in scope for 10 CFR 54.4(a)(2).
Discussion:
The staff was not clear why the unloader line was not considered as part of the pressure boundary and relied upon to perform a safety-related function. The applicant agreed to supplement its response to RAI 2.3.3.14-1 to address the staff's concerns.
RAI4.7.5-2 In its supplemental response to RAI4.7.5-2, the applicant provided details of the flaw evaluation for RHR piping well WIC-95.
Discussion:
The staff noted that based on the indication from the flaw evaluation, the flaw should be considered surface connected per the American Society of Mechanical Engineers Boiler and Pressure Vessel Code,Section XI IWA-3310. The staff also noted that the applicant did not consider the flaw surface connected in its evaluation. The applicant agreed to supplement its response to RAI 4.7.5-2 to address the staff's concern.
February 7, 2011 LICENSEE:
Pacific Gas and Electric Company FACILITY:
Diablo Canyon Nuclear Power Plant, Units 1 and 2
SUBJECT:
SUMMARY
OF TELEPHONE CONFERENCE CALL HELD ON DECEMBER 14, 2010, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND PACIFIC GAS AND ELECTRIC COMPANY CONCERNING REQUESTS FOR ADDITIONAL INFORMATION RESPONSE RELATED TO THE DIABLO CANYON NUCLEAR POWER PLANT, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION (TAC NUMBERS ME2896 AND ME2897)
The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of Pacific Gas and Electric Company (PG&E or the applicant) held a telephone conference call on December 14,2010, to obtain clarification on PG&E's responses to the staff's requests for additional information (RAI) regarding the Diablo Canyon Nuclear Power Plant license renewal application.
By letters dated October 12, 15,27, November 3, and 8, 2010, PG&E sent the staff its responses to RAls regarding scoping and screening and TLAAs. The staff reviewed the information contained therein, and requested a telephone conference call. The telephone conference call was useful in clarifying PG&E's response. Enclosure 1 provides a listing of the participants. Enclosure 2 provides discussions on the RAI response for which the staff requested clarification.
The applicant had an opportunity to comment on this summary.
IRA!
Nathaniel B. Ferrer, Project Manager Projects Branch 2 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-275 and 50-323
Enclosures:
As stated cc w/encls: Distribution via Listserv DISTRIBUTION:
See next page ADAMS Accession Number: ML110120418 OFFICE LA: DLR PM: DLR/RPB2 BC: DLR/RPB2 PM: DLR/RPB2 NAME YEdmonds NFerrer DWrona NFerrer DATE 01/21/2011 01/26/2011 01/31/2011 02/07/2011 OFFICIAL RECORD COPY
Letter to Pacific Gas and Electric Company from Nathaniel B. Ferrer dated February 7, 2011
SUBJECT:
SUMMARY
OF TELEPHONE CONFERENCE CALL HELD ON DECEMBER 14, 2010, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND PACIFIC GAS AND ELECTRIC COMPANY CONCERNING REQUESTS FOR ADDITIONAL INFORMATION RESPONSE RELATED TO THE DIABLO CANYON NUCLEAR POWER PLANT, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION (TAC NUMBERS ME2896 AND ME2897)
DISTRIBUTION:
HARD COPY:
DLR R/F E-MAII_:
PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRarb Resource RidsNrrDlrRapb Resource RidsNrrDlrRasb Resource RidsNrrDlrRerb Resource RidsNrrDlrRpob Resource RidsOgcMailCenter Resource NFerrer KGreen AStuyvenberg DWrona AWang MPeck, RIV TBrown, RI GMiller, RIV NO'Keefe, RIV ICouret,OPA VDricks, OPA WMaier, RIV JWeil,OCA EWilliamson,OGC SUttal,OGC RRihm, EDO