OPERATING TEST COMMENTS JPM COMMENTS
- 1. JPM No. 2010-301-AT-01R - Unable to setup simulator to support performance of MODE 5 Shiftly/Daily Surveillance
- a. Changed from a MODE 5 to MODE 4 surveillance
- b. Changed K/A from 2.1.44 to 2.1.18
- c. Changed task elements due to changes in MODE to include:
- i. Recording of Torus Water Level ii. Recording of RPV Flange Temperature iii. Identification abnormal indication for annunciator 3D57 iv. Identification of abnormal RHR configuration
- v. Identification of abnormal SRM indication
- 2. JPM No. 2010-301-AT-01S
- b. Changed SRM verification step
- i. From 1 SRM below 3 cps to 2 SRMs below 3 cps ii. Included completed SRM signal to noise verification packages to be evaluated
- c. Included Secondary Containment Differential Pressure Correction Tables as required material
- 3. JPM No. 2010-301-AT-02
- a. Revised to allow use of IPCS including addition of appropriate cues
- b. Revised to include data tables (information to be provided when requested);
allows performance in classroom setting rather than in Simulator
- 4. JPM No. 2010-301-AT-03S
- a. Changed task from Assess Shutdown Risk to Evaluate a Temporary Change Notice since procedure guidance for assessing risk was too generic to support a JPM.
- b. Replacement JPM from bank
- 5. JPM No. 2010-301-AT-04R
- a. Changed to RO only
- b. Revised required materials to include Mock Up RWP and Survey Map
- 6. JPM No. 2010-301-AT-04S
- b. Replacement JPM from bank
- 7. JPM No. 2010-301-AT-05S
- a. Updated to reflect changes in procedure.
- 8. JPM No. 2010-301-CR-04
- a. Included a recommended IC for setup
- b. Added clarifying information to evaluator prompt and note
- 9. JPM No. 2010-301-CR-05
- a. Added step to setup to ensure that injection path is isolated
- b. Added step to un-isolate injection path
- c. Included preferred level band in evaluator notes.
- 10. JPM No. 2010-301-CR-07
- a. Added guidance for simulator operator to act as RO responsible for maintaining reactor period and ranging of IRMs
- 11. JPM No. 2010-301-IP-02
- a. Changed valve number and fuse location to simplify access to panel
- 12. JPM No. 2010-301-IP-03
- a. Added clarifying information for evaluator
- b. Added missed step SCENARIO COMMENTS
- 1. Scenario 1
- a. Eliminated reactivity manipulation to shorten scenario run time
- b. Increased delay time for sticking IRM to provide a more noticeable indication of failure.
- c. Included additional role play messages for communicator
- d. Added clarification that applicants may isolate RCIC before auto isolation signal is actuated
- e. Added clarifying note for CRD Flow transmitter failure
- f.
Added clarifying not related to exiting ATWS EOP power leg to SCRAM AOP
- g. Changed mechanical vacuum pump failure from a credited component failure to simply an observation of failure
- 2. Scenario 2
- a. Changed RR Pump trip event type from Reactivity Manipulation to Component malfunction due to insufficient time between initiation of malfunction and automatic trip of pump.
- b. Added Role-Play communications
- c. Revised Bypass Valve Test expected actions to include both procedurally allowed methods for reclosing valve.
- d. Revised expected TS actions for failed accumulator to provide more detail
- e. Added expectation for insertion of CRAM array in response to RR Pump Trip
- f.
Revised response actions for Feed Pump suction strainer clogging to include possibility that applicants may trip pump rather than perform a controlled shutdown of pump (power already low enough to support single pump operation due to RR pump trip response)
- 3. Scenario 3
- a. Changed CW system rupture event type from Major to Component failure.
- b. Revised severity of SBFW Injection valve failure to permit some injection to ensure that response to small break LOCA is driven by containment parameters and not RPV parameters
- c. Eliminated RCIC malfunction and changed HPCI failure from a credited malfunction to recognition of failure.
- d. Added Role-Play communications
- e. Changed stator water cooling malfunction from TCV failure to HX fouling
- f.
Added clarifying information where needed.