ML101970453

From kanterella
Jump to navigation Jump to search

E-mail from R. Guzman to T. Darling Request for Additional Information Extended Power Uprate LAR - Clarification in Fire Protection Review RAI D1, D3
ML101970453
Person / Time
Site: Nine Mile Point Constellation icon.png
Issue date: 02/01/2010
From: Richard Guzman
Division of Operating Reactor Licensing
To: Darling T
Nine Mile Point
Guzman R, NRR/DORL, 415-1030
References
TAC ME1476
Download: ML101970453 (2)


Text

From: Guzman, Richard Sent: Monday, February 01, 2010 11:55 AM To: Darling, Theresa H; Dosa, John J

Subject:

RE: Follow-up re: Piping & NDE Call John, Theresa -

For D1, the staff would like to understand the NMP2 application of the GE BWROG TR relative to the associated 10 CFR requirements. In other words, how is the criteria being changed in reference to the TR, and still meeting all associated requirements (e.g., 10 CFR 50 App R).

For D3, the staff requests clarification to NMP2 core cooling assurance using RCIC or pseudo LPCI, and actions needed to get plant to cold S/D. Is licensee/NMP2 relying on RCIC until operator can get to remote S/D panel? Is licensee's approach consistent with the regulations?

Sorry for the delay in getting this additional info to you.

Rich Guzman 301-415-1030 From: Darling, Theresa H [1]

Sent: Monday, February 01, 2010 10:25 AM To: Guzman, Richard Cc: Dosa, John J

Subject:

RE: Follow-up re: Piping & NDE Call Yes we have this action. Do you have the questions from the Fire Protection Branch on D1 or D3?

From: Guzman, Richard [2]

Sent: Monday, February 01, 2010 10:24 AM To: Darling, Theresa H

Subject:

Follow-up re: Piping & NDE Call

Theresa, I understand from Jay Wallace that the question we had on the MSIP weld was addressed - specifically, that the weld (2RPV-KC-32) does not have a weld overlay and it will be inspected every 6 years per BWRVIP-75. I understand that you can provide a supplement on the docket. I recommend that you reference the 1/27 phone call in the letter.

Please confirm you have this for action and advise when I should expect the letter.

Thanks, Rich Rich Guzman Sr. Project Manager NRR/DORL US NRC 301-415-1030 Richard.Guzman@nrc.gov

>>> This e-mail and any attachments are confidential, may contain legal, professional or other privileged information, and are intended solely for the addressee. If you are not the intended recipient, do not use the information in this e-mail in any way, delete this e-mail and notify the sender. CEG-IP2 E-mail Properties Mail Envelope Properties (92E0E77F3622DA40B501E8D45083D5D9508499081F)

Subject:

RE: Follow-up re: Piping & NDE Call Sent Date: 2/1/2010 10:40:34 AM Received Date: 2/1/2010 11:54:00 AM From: Guzman, Richard Created By: Richard.Guzman@nrc.gov Recipients:

Theresa.Darling@cengllc.com (Darling, Theresa H)

Tracking Status: None John.Dosa@cengllc.com (Dosa, John J)

Tracking Status: None Post Office:

HQCLSTR01.nrc.gov Files Size Date & Time MESSAGE 12518 2/1/2010 Options Expiration Date:

Priority: olImportanceNormal ReplyRequested: False Return Notification: False Sensitivity: olNormal Recipients received: