From:

Guzman, Richard Sent:

Tuesday, June 15, 2010 12:41 PM To:

Darling, Theresa H Cc:

Dosa, John J

Subject:

NMP2 EPU Follow-up RAIs - Reactor Systems

Theresa, Please see follow-up RAI questions below. If necessary, we can look to have a phone call this Thursday for any clarification(s) needed to respond to the questions.
Thanks, Rich

Follow-up RAIs to June 3, 2010 NMPNS RAI Response Letter re: NMP2 License Amendment Request for EPU Operation----------------------

1. Regarding NMPNS response to NMP2-SRXB-RAI-5: Please submit the MCNP01A validation document to support the completion of the NRC staffs safety evaluation and review.
2. Regarding NMPNS response to NMP2-SRXB-RAI-5: Simply stating that [f]ission products benchmarks were not available and thus were not included in the validation set, is not appropriate. Table 12 of NEDC-33374P, Rev. 3, Safety Analysis Report for Fuel Storage Racks Criticality Analysis for ESBWR Plants, addresses the validation gaps associated with fission products and actinides. Address these validation gaps for NMP2.
3. Regarding NMPNS response to NMP2-SRXB-RAI-9: Table 12 of NEDC-33374P, Rev.

3, Safety Analysis Report for Fuel Storage Racks Criticality Analysis for ESBWR Plants, included a rack sliding bias of approximately 1500 pcm. The NRC staff understands that the ESBWR criticality analysis also assumed a no leakage condition.

Please provide a discussion explaining why the NMP2 analysis does not need to account for this bias.


Follow-up RAIs to June 3, 2010 NMPNS RAI Response Letter re: NMP2 License Amendment Request for EPU Operation----------------------

E-mail Properties Mail Envelope Properties (F5A4366DF596BF458646C9D433EA37D72F8165D313)

Subject:

NMP2 EPU Follow-up RAIs - Reactor Systems Sent Date: 6/15/2010 12:40:38 PM Received Date: 6/15/2010 12:40:00 PM

From: Guzman, Richard Created By: Richard.Guzman@nrc.gov Recipients:

Theresa.Darling@cengllc.com (Darling, Theresa H)

Tracking Status: None John.Dosa@cengllc.com (Dosa, John J)

Tracking Status: None Post Office:

HQCLSTR01.nrc.gov Files Size Date & Time MESSAGE 10835 6/15/2010 Options Expiration Date:

Priority: olImportanceNormal ReplyRequested: False Return Notification: False Sensitivity: olNormal Recipients received: