( PL JUN 3 0 2008 L-2008-138 10 CFR 50.54(f)

U. S. Nuclear Regulatory Commission ATTN: Document Control Desk 11555 Rockville Pike Rockville, Maryland 20852 Florida Power & Light Company, Turkey Point Unit 3 Docket No. 50-250

Subject:

Supplemental Response to NRC Generic Letter 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors"

References:

(1)

Generic Letter 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors," dated September 13, 2004 (2)

Letter L-2005-034 from J. A. Stall (FPL) to U. S. Nuclear Regulatory Commission "Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized Water Reactors," dated March 4, 2005 (ML050670429)

(3)

Letter from E. A. Brown (U. S. Nuclear Regulatory Commission) to J. A.

Stall (FPL), "Turkey Point Plant, Units 3 and 4 - Request for Additional Information (RAI) Related to Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized Water Reactors,"

dated June 2,

2005 (ML051520202)

(4)

Letter L-2005-145 from J. A. Stall (FPL) to U. S. Nuclear Regulatory Commission "Request for Additional Information - Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized Water Reactors,"

dated July 20, 2005 (ML052080038)

(5)

Letter L-2005-181 from J. A. Stall (FPL) to U. S. Nuclear Regulatory Commission "Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized Water Reactors - Second Response," dated September 1, 2005 (ML052490339)

(6)

Letter from B. T. Moroney (U. S. Nuclear Regulatory Commission) to J. A.

Stall (FPL) "Turkey Point, Units 3 and 4, Request for Additional Information Re: Response to Generic letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design-Basis Accidents at Pressurized-Water Reactors," dated February 8, 2006 (ML060370438)

/

an FPL Group company

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 2 of 4 (7)

Letter from C. T. Haney (U. S. Nuclear Regulatory Commission) to Holders of Operating Licensees for Pressurized Water Reactors, "Alternate Approach for Responding to the Nuclear Regulatory Commission Request for Additional Information RE: Generic Letter 2004-02," dated March 28, 2006 (ML060860257)

(8)

Letter from C. T. Haney (U. S. Nuclear Regulatory Commission) to Holders of Operating Licenses for Pressurized Water Reactors, "Alternate Approach for Responding to the Nuclear Regulatory Commission Request for Additional Information Letter Regarding Generic Letter 2004-02," dated January 4, 2007 (ML063460258)

(9)

Letter from W. H. Ruland (U. S. Nuclear Regulatory Commission) to A.

Pietrangelo (Nuclear Energy Institute), "Content Guide for Generic Letter 2004-02 Supplemental Responses,"

dated August 15, 2007 (ML071060091)

(10) Letter from W. H. Ruland (U. S. Nuclear Regulatory Commission) to A.

Pietrangelo (Nuclear Energy Institute), "Revised Content Guide for Generic Letter 2004-02 Supplemental Responses," dated November 21, 2007 (ML073110389)

(11)

Letter from W. H. Ruland (U. S. Nuclear Regulatory Commission) to A.

Pietrangelo (Nuclear Energy Institute), "Supplemental Licensee Responses to Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors," dated November 30, 2007 (ML073320176)

(12) Letter L-2007-155 from J. A. Stall (FPL) to U. S. Nuclear Regulatory Commission "Request for Extension of Completion Date of the St. Lucie Unit 1, St. Lucie Unit 2 and Turkey Point Unit 3 Generic Letter 2004-02 Actions," dated December 7, 2007 (ML073450338)

(13) Letter L-2007-194 from J. A. Stall (FPL) to U. S. Nuclear Regulatory Commission "Response to Questions Regarding Request for Extension of Completion Date of the St. Lucie Unit 1, St. Lucie Unit 2 and Turkey Point Unit 3 Generic Letter 2004-02 Actions," dated December 20, 2007 (ML080090147)

(14) Letter from T. H. Boyce (U. S. Nuclear Regulatory Commission) to J. A.

Stall (FPL) "St. Lucie Nuclear Plant, Units 1 and 2, and Turkey Point Nuclear Plant, Unit 3 - Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized Water Reactors, Extension Request Evaluation,"

dated December 28, 2007 (ML073610401)

(15) Letter L-2008-033 from W. Jefferson, Jr.,. (FPL) to U. S. Nuclear Regulatory Commission "Supplemental Response to NRC Generic Letter 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation During

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 3 of 4 Design Basis Accidents at Pressurized-Water Reactors," dated February 28, 2008 (ML080710429)

The purpose of this submittal is to provide the Florida Power and Light Company (FPL) updated supplemental response to Generic Letter (GL) 2004-02 (Reference 1).

The U. S. Nuclear Regulatory Commission (NRC) issued Reference 1 to request that addressees perform an evaluation of the emergency core cooling system (ECCS) and containment spray system (CSS) recirculation functions in light of the information provided in the GL and, if appropriate, take additional actions to ensure system functions.

Additionally, the GL requested addressees to provide the NRC with a written response in accordance with 10 CFR 50.54(f). The request was based on identified potential susceptibility of the pressurized water reactor (PWR) recirculation sump screens to debris blockage during design basis accidents requiring recirculation operation of ECCS or CSS and on the potential for additional adverse effects due to debris blockage of flowpaths necessary for ECCS and CSS recirculation and containment drainage.

Reference 2 provided the initial Florida Power and Light Company (FPL) response to the GL.

Reference 3 requested additional information regarding the Reference 2 response to the GL for Turkey Point Plant Units 3 and 4.

Reference 4 provided the FPL response to Reference 3.

Reference 5 provided the second of two responses requested by the GL.

Reference 6 requested FPL to provide additional information to support the NRC staff's review of Reference 2, as supplemented by References 4 and 5.

Reference 7 provided an alternative approach and timetable that licensees may use to address outstanding requests for additional information (i.e., Reference 7). Reference 8 supplemented Reference 7 with the NRC expectation that all GL 2004-02 responses will be provided no later than December 31, 2007. For those licensees granted extensions to allow installation of certain equipment in spring 2008, the NRC staff expects that the facility response will be appropriately updated with any substantive GL corrective action analytical results or technical detail changes within 90 days of the change or outage completion. As further described in Reference 8, the NRC expects that all licensees will inform the NRC, either in supplemental GL 2004-02 responses or by separate correspondence as appropriate, when all GSI-191 actions are complete.

Reference 9 describes the content to be provided in a licensee's final GL 2004-02 response that the NRC staff believes would be sufficient to support closure of the GL. Reference 10 revised the guidance provided in Reference 9 by incorporating minor changes which were viewed by the NRC as clarifications.

Reference 11 authorized all PWR licensees up to two months beyond December 31, 2007 (i.e.,

to February 29, 2008) to provide the supplemental responses to the NRC.

In Reference 12, FPL requested an extension for completing Turkey Point Unit 3 chemical effects testing and analysis activities until June 30, 2008, and in-vessel and ex-vessel downstream effects evaluations until March 31, 2008. Reference 13 provided FPL's response to NRC questions regarding Reference 12. The request for an extension was approved in the Reference 14 evaluation.

In Reference 15, FPL provided the initial GL 2004-02 supplemental response using the content guide provided in Reference 9. This letter provides an updated supplemental response, as

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 4 of 4 discussed in References 12, 13, 14, and 15, using the NRC Revised Content Guide for GL 2004-02 Supplemental Responses, dated November 21, 2007, that was provided by the NRC in Reference 10. provides a summary level description of the approach taken to provide reasonable assurance that long-term core cooling is maintained, as requested by the revised content guide. provides the updated supplemental response to GL 2004-02 for Turkey Point Units 3. Information previously provided, in Reference 15, continues to apply except where supplemented or revised. A revision bar in the right hand margin of the updated supplemental response indicates where information has been either supplemented or revised.

This letter also serves to inform the NRC that all GL 2004-02 related GSI-191 actions for Turkey Point Unit 3 are complete.

There are no new regulatory commitments made by FPL in this submittal.

This information is being provided in accordance with 10 CFR 50.54(f).

Please contact Olga Hanek, at (305) 246-6607, if you have any questions regarding this response.

I declare under penalty of perjury that the foregoing is true and correct.

Executed on June,

, 2008.

William Jefftlr'son, Jr4-,"

Site Vice President Turkey Point Nuclear Plant Attachments: (2) cc:

NRC Regional Administrator, Region II USNRC Project Manager, Turkey Point Nuclear Plant Senior Resident Inspector, USNRC, Turkey Point Nuclear Plant

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 1 of 3 ATTACHMENT 1 Turkey Point Unit 3 GL 2004-02 Summary Description of Approach

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 2 of 3

SUMMARY

DESCRIPTION OF APPROACH The following key aspects summarize the FPL approach to GL 2004-02 at Turkey Point Unit 3.

Design Modifications New sump strainers ensure adequate NPSH during recirculation with margin for chemical effects.

Removal of the PRT insulation and replacement of the RCP and Pressurizer drain surge line insulation with Reflective Metal Insulation (RMI) ensures that strainer design basis fiber debris loads will not be exceeded.

Process Changes SPEC-C-034 (re: Protective Coatings) update ensures that strainer design basis coating debris loads will not be exceeded.

Procedure 0-SMM-051.3 (Containment Closeout Inspection) ensures that the potential choke point, refueling canal drain covers, will be removed prior to restart so that the design basis sump water supply will be available.

Supporting Analyses Downstream effects evaluations confirmed that no other modifications are required to ensure long-term cooling capability is maintained.

Coating adhesion tests confirm that current inspection methods are adequate to control quantity of degraded qualified coatings.

Evaluation of in-vessel chemical effects confirms that fuel temperatures will be maintained at an acceptable low value.

Conservatisms and Margin FPL has made improvements in the ECCS system to address the issues identified in Generic Letter 2004-02. As part of the analysis, FPL has included a number of conservatisms to ensure sufficient margin is available. These margins are summarized below.

The new sump strainer system installed in PTN-3 in the fall of 2007 is a General Electric design with a surface area of approximately 5,500 ft2 with 3/32-inch perforations to retain debris. The new strainers replaced the previous sump screens which had a combined total surface area of approximately 63 ft2 with a %-inch screen mesh.

Debris head loss testing was performed for a variety of surface areas. Although testing demonstrated that acceptable debris head losses could be obtained for 3,256 ft2, FPL installed approximately 5,500 ft2 for additional margin.

" A uniform factor of 1.1 has been applied to the ZOI radius to ensure the calculation was conservative.

100% of the Calcium Silicate (cal-sil) generated is assumed to transport to the strainers.

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 3 of 3 100% of unqualified coatings, regardless of types and location inside containment, were assumed to fail as particulates and transport to the screen. EPRI and industry testing indicates some unqualified coatings do not fail and some coatings fail as chips and may not transport to the sump.

The near-field effect was not credited in the debris head loss testing. The steps taken to minimize near-field effects in the tests included placing the flow return near the bottom of the test tank to help suspend debris, and using five (5) motor driven agitators to ensure that debris remained suspended. This maximizes the amount of debris on the screen and will provide very conservative results.

The design basis flow strainer flow rates are 2,697 gpm for the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and then 3,750 gpm at 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. 3,750 gpm, which represents a 39% increase in the maximum flow, was utilized from initiation in the debris head loss testing. This higher flow rate provides conservative head loss numbers.

The combination of these design modifications, process changes, and supporting analysis provides reasonable assurance that long-term core cooling is maintained.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 1 of 89 ATTACHMENT 2 Turkey Point Unit 3 GL 2004-02 Updated Supplemental Response

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 2 of 89 UPDATED SUPPLEMENTAL RESPONSE TO GL 2004-02 This final supplemental response to NRC Generic Letter (GL) 2004-02 updates the information previously submitted in FPL letter L-2008-033, Supplemental Response to NRC Generic Letter 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors," dated February 28, 2008. Changes to the original supplemental response are indicated by revision bars. Where original text was relocated to meet the format requirements of the NRC staff's November 2007 guidance document, but otherwise unchanged, the text is shown as boxed text.

Additional information to support the staff's evaluation of Turkey Point Unit 3 compliance with the regulatory requirements of GL 2004-02 was requested by the NRC in a "Request for Additional Information" (RAI) dated February 8, 2006 (NRC Letter to FPL (J. A. Stall), Turkey Point Plant, Units 3 and 4, "Request for Additional Information RE: Response to Generic Letter 2004-02, 'Potential Impact of Debris Blockage on Emergency Sump Recirculation at Pressurized-Water Reactors"' (TAC Nos. MC4725 and MC4726), February 8, 2006). Each RAI question is addressed in this response. The RAI question (and specific RAI response) is identified by the RAI question number in the following format: [RAI ##], where ## is the RAI question number. As above, where information related to chemical effects or the results of downstream analysis was incomplete it is provided in this final supplemental response in accordance with the schedule provided to the NRC staff in FPL letter L-2007-155, dated December 7, 2007.

Topic 1: Overall Compliance FPL Response The response to GL 2004-02 that was submitted to the NRC on September 1, 2005 (September 1 response) was based on the information that was available at that time. Subsequent to the September 1 response, all identified corrective actions have been completed (e.g., installation of new sump strainers and removal of fibrous insulation from areas where it could contribute to the strainer debris load and downstream effects). In addition, improvements in programmatic controls have been implemented to ensure that the potential quantity of debris is maintained within the new sump strainer design values.

These corrective actions have created NPSH margin, reduced the size of debris that can pass through the sump strainers, and reduced the maximum quantity of fiber that could be generated and transported to the sump strainers. Walkdowns have confirmed that the only potential choke points that could prevent the design basis volume of water from being available for recirculation are the refueling canal drain covers. Procedural controls have been put in place to ensure that refueling canal drain covers which could cause a potential choke point are removed prior to restart from an outage.

Based on the completed corrective actions and enhanced procedural controls, and based upon completion of the confirmatory tests and analyses, Table 1-1 provides the information which demonstrates Turkey Point Unit 3 compliance with the regulatory requirements listed in GL 2004-02.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 3 of 89 Table 1-1: GL 2004-02 Regulatory Compliance Regulatory Applicable Requirement Basis For Compliance Statute 10 CFR 50.46 Long-term cooling. After any calculated New sump strainers ensure adequate (b)(5) successful initial operation of the ECCS, the NPSH during recirculation with margin calculated core temperature shall be for chemical effects maintained at an acceptably low value and 0

Removal of the PRT insulation and decay heat shall be removed for the extended replacement of the RCP and period of time required by the long-lived Pressurizer surge line insulation with radioactivity remaining in the core.

Reflective Metal Insulation (RMI) ensures that strainer design basis fiber debris loads will not be exceeded 0

SPEC-C-034 update ensures that strainer design basis coating debris loads will not be exceeded 0

Procedure 0-SMM-051.3 ensures that the potential choke point, refueling canal drain covers, will be removed prior to restart so that the design basis sump water supply will be available 0

Resolution of pump issues ensures that ECCS pumps can provide long term cooling capability 0

Downstream effects evaluations confirmed that no other modifications are required to ensure long-term cooling capability is maintained Coating adhesion tests confirm that current inspection methods are adequate to control quantity of degraded qualified coatings Evaluation of in-vessel chemical effects confirms that fuel temperatures will be maintained at an acceptable low value 10 CFR 50, Criterion 35--Emergency core cooling. A The assurance of long-term cooling Appendix A, system to provide abundant emergency core capability during recirculation ensures that GDC 35 cooling shall be provided. The system safety the design basis emergency core cooling function shall be to transfer heat from the capabilities are maintained reactor core following any loss of reactor coolant at a rate such that (1) fuel and clad damage that could interfere with continued effective core cooling is prevented and (2) clad metal-water reaction is limited to negligible amounts.

10 CFR 50, Criterion 38--Containment heat removal. A The assurance of long-term cooling Appendix A, system to remove heat from the reactor capability for the Containment Spray GDC 38 containment shall be provided. The system System (CSS) pumps during recirculation safety function shall be to reduce rapidly, ensures that the design basis containment consistent with the functioning of other heat removal capabilities are maintained associated systems, the containment pressure and temperature following any loss-of-coolant accident and maintain them at acceptably low levels.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 4 of 89 Table 1-1: GL 2004-02 Regulatory Compliance Regulatory Applicable Requirement Basis For Compliance Statute 10 CFR 50, Criterion 41--Containment atmosphere The containment atmosphere clean up Appendix A, cleanup. Systems to control fission products, system is not affected by GS1-191 issues GDC 41 hydrogen, oxygen, and other substances because it does not rely on ECCS which may be released into the reactor recirculation to perform its intended function containment shall be provided as necessary to reduce, consistent with the functioning of other associated systems, the concentration and quality of fission products released to the environment following postulated accidents, and to control the concentration of hydrogen or oxygen and other substances in the containment atmosphere following postulated accidents to assure that containment integrity is maintained.

FPL has made significant improvements in the ECCS system to address the issues identified in Generic Letter 2004-02. As part of the analysis, FPL has included a number of conservatisms to ensure sufficient margin is available. These margins are summarized below.

The new sump strainer system installed in PTN-3 in the fall of 2007 is a General Electric design with a surface area of approximately 5,500 ft2 with 3/32-inch perforations to retain debris. The new strainers replaced the previous sump screens which had a combined total surface area of approximately 63 ft2 with a %-inch screen mesh.

0 Debris head loss testing was performed for a variety of surface areas. Although testing demonstrated that acceptable debris head losses could be obtained for 3,256 ft2, FPL installed approximately 5,500 ft2 for additional margin.

A uniform factor of 1.1 has been applied to the ZOI radius to ensure the calculation was conservative.

100% of the Calcium Silicate (cal-sil) generated is assumed to transport to the strainers.

100% of unqualified coatings, regardless of types and location inside containment, were assumed to fail as particulates and transport to the screen. EPRI and industry testing indicates some unqualified coatings do not fail and some coatings fail as chips and may not transport to the sump.

0 The near-field effect was not credited in the debris head loss testing. The steps taken to minimize near-field effects in the tests included placing the flow return near the bottom of the test tank to help suspend debris, and using motor driven agitators to ensure that debris remained suspended. This maximizes the amount of debris on the screen and will provide very conservative results.

The design basis strainer flow rates are 2,697 gpm for the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and then 3,750 gpm at 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. 3,750 gpm, which represents the maximum flow, was utilized from initiation in the debris head loss testing.

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 5 of 89 Topic 2: General Description of and Schedule for Corrective Actions FPL Response The corrective actions identified for Turkey Point Unit 3 have been completed. Florida Power &

Light requested, and received, a short extension to complete selected confirmatory tests and analyses. The delayed tests and analyses were those that depended on the resolution of chemical effects issues or those that were impacted by the recent revision to WCAP-16406-P, Evaluation of Downstream Sump Debris Effects in Support of GSI-191, Revision 1, August, 2007.

A general description of the actions taken is presented below. Additional details are contained in subsequent sections of this response.

The original sump screens have been completely replaced with a strainer system that has a total strainer surface area of approximately 5,543 ft2. The new system consists of 12 strainer modules with interconnecting piping and is passive (i.e., it does not have any active components or rely on backflushing). The strainer system is described in the response to NRC Topic 3.j, Screen Modification Package.

Three insulation modifications have been completed that reduce the quantities of fibrous and particulate debris that could be transported to the sump strainers. These modifications replaced the insulation on the Pressurizer Surge Line with reflective metal insulation (RMI),

replaced the insulation on the Reactor Coolant Pumps with RMI, and removed the insulation from the Pressurizer Relief Tank (PRT).

A walkdown confirmed that the only potential choke points are the fuel transfer canal drain covers at the bottom of the refueling canal. These potential choke points have been removed by updating the closeout procedure to ensure that the drain covers are removed prior to restart.

The downstream effects assessments of the fuel and vessel are complete. FPL participated in the PWR Owners Group (PWROG) program to evaluate downstream effects related to in-vessel long-term cooling using the methodology of WCAP-16793-NP "Evaluation of Long-Term Cooling Considering Particulate, Fibrous and Chemical Debris in the Recirculating Fluid," Rev.

0. A Turkey Point Unit 3 calculation, using plant-specific parameters and WCAP-1 6793-NP methodology, confirms that chemical plate-out on the fuel is acceptable. This assessment was completed in accordance with the schedule provided to the NRC staff in FPL letter L-2007-155, dated December 7, 2007.

The downstream effects assessment of components was revised to incorporate the methodology of WCAP-16406-P, Revision 1, "Evaluation of Downstream Sump Debris Effects in Support of GSI-191." This assessment was completed in accordance with the schedule provided to the NRC staff in letter L-2007-155. An additional issue with the High Head Safety Injection pumps not meeting the shaft stiffness acceptance criteria (per WCAP-1 6406-P Revision 1) was identified to the NRC, indicating that the final ex-vessel downstream effects analytical results would be provided to the NRC by June 30, 2008. FPL refined the downstream High Head Safety Injection pump analysis to demonstrate the pump meets the WCAP shaft stiffness acceptance criteria.

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 6 of 89 Enhancements to programmatic controls have been put in place at Turkey Point Unit 3.

Engineering procedures have been revised to provide guidance to design engineers working on plant modifications to take into account the impact of the design on the "containment sump debris generation & transport analysis and/or recirculation functions."

As an enhancement to the existing process for controlling the quantities of piping insulation within the containment, the engineering specification that controls thermal insulation was revised to provide additional guidance for maintaining containment insulation configuration.

New controls have been instituted limiting the permissible quantity of unqualified coatings in the containment building to ensure that the ECCS strainer design requirements, as documented in the Turkey Point Unit 3 debris generation calculation, remain within permissible limits.

Based on the results of the latent and foreign material walkdowns that were performed, it was determined that changes in the Turkey Point Unit 3 housekeeping procedures were not required because of the limited amount of material observed.

Chemical effects testing was performed by Alion Science and Technology. This testing was completed in accordance with the schedule provided to the NRC staff in letter L-2007-155.

The results of the tests and analyses indicate that no additional corrective actions are needed to comply with the regulatory requirements of GL 2004-02.

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 7 of 89 Specific Information Regarding Methodology for Demonstrating Compliance:

Topic 3.a: Break Selection FPL Response In agreement with the staff's SE of NEI 04-07, the objective of the break selection process was to identify the break size and location which results in debris generation that will maximize the head loss across the containment sump. Breaks were evaluated based on the methodology in Nuclear Energy Institute (NEI) guidance document NEI 04-07, as modified by the staff's SE for NEI 04-07.

The Nuclear Steam Supply System (NSSS) system is located between a bioshield wall near the outer wall of containment and a primary shield that surrounds the reactor cavity. The bioshield is a two-piece wall with one wall starting at the floor and extending up, and the other starting at the ceiling and extending down. The two walls are offset so that they do not intersect, which creates an opening between them due to their overlap. This opening can provide a path for jet impingement on piping outside the bioshield by breaks inside the bioshield (or vice versa). An evaluation of potential breaks and potential targets in both the inner annulus and the outer annulus was performed. The evaluation concluded that the effect of this opening is negligible, and that the opening does not affect the selection of the limiting break.

[RAI 33] The following specific break location criteria were considered:

Breaks in the reactor coolant system with the largest.amount of potential debris within the postulated ZOI, Large breaks with two or more different types of debris, including breaks with the most variety of debris, Breaks in areas with the most direct path to the sump, Medium and large breaks with the largest potential particulate debris to insulation ratio by weight, and Breaks that generate an amount of fibrous debris that, after transport to the surnp strainer, could form a uniform "thin bed."

[RAI 34] All Reactor Coolant System (RCS) piping and attached energized piping was evaluated for potential break locations. Inside the bioshield breaks in the hot legs (29-inch ID),

cold legs (271/2 -inch ID), crossover legs (31-inch ID), pressurizer surge line (14-inch nominal) and Residual Heat Removal (RHR) recirculation line from the hot leg (14-inch nominal), were considered. Feedwater and main steam piping was not considered for potential break locations because ECCS in recirculation mode is not required for Main Steam or Feedwater line breaks.

The other piping lines have smaller diameters (10-inch nominal maximum), which will produce a much smaller quantity of debris.

[RAI 33] Inside the bioshield the break selection process used the discrete approach described in Section 3.3.5.2 of the staff's SE of NEI 04-07. The staff's SE of NEI 04-07 notes that the concept of equal increments is only a reminder to be systematic and thorough. As stated in the staff's SE of NEI 04-07, the key difference between many breaks (especially large breaks) will not be the exact location along the pipe, but rather the envelope of containment material targets that is affected. Consistent with this guidance, break locations were selected based on the total debris, mixture of debris, and distance from the sump. Containment symmetry

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 8 of 89 ensures similar results for each break, but each break is also unique in certain aspects, and this was considered in the break selection process. The crossover leg is the largest line (31-inch ID) inside the bioshield and would produce the largest zone of influence (ZOI). A crossover leg break is analyzed in loops B and C in order to maximize the ZOI radius which maximizes the insulation encircled. A cold leg break in loop A is chosen for its proximity to a large amount of calcium silicate (cal-sil) insulation.

Outside the bioshield a break was considered in an RHR line. The RHR lines are of smaller diameter than the RCS piping. Therefore, inside the bioshield, a break in these lines would be bounded by the reactor coolant loops, and thus need not be analyzed. However, the RHR recirculation line travels outside the bioshield before the second isolation valve. This location was selected in order to include a break outside the bioshield.

The postulated break locations were as follows:

S1 The Loop B Crossover Leg at the base of the reactor coolant pump (31-inch ID)

S2 The Loop C Crossover Leg at the low point of the pipe (31-inch ID)

S3 The Loop A Cold Leg at the base of the reactor coolant pump (27.5-inch ID)

S5 The RHR line RC-2501R from Loop C Hot Leg outside the bioshield (14-inch nominal)

Break S1 generated the greatest quantity of cal-sil debris. Therefore it was selected for the strainer design basis.

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 9 of 89 Topic 3.b: Debris Generation/Zone of Influence (ZOI) (excluding coatin.qs)

FPL Response The debris generation calculations used the methodologies of Regulatory Guide 1.82, Rev. 3, and the staff's SE of NEI 04-07. However, there have been changes in the input to the analyses since the September 1 response.

Debris specific ZOIs were used in the debris generation calculations for calcium-silicate (cal-sil),

low density fiber glass (LDFG) and reflective insulation. ZOls for commonly used insulation were obtained from Table 3-2 and § 3.4.2.2 of the staff's SE of NEI 04-07. Specific insulation ZOIs that were used are: 17D for Nukon (fiber) insulation, 5.45D for Calcium Silicate (cal-sil) insulation, 28.6D for Mirror reflective metallic insulation (RMI), and 2.OD for Transco/Darchem RMI. The ZOI for Min-K insulation, 28.6D, was used for Microtherm insulation. This value was selected because Microtherm and Min-K are similar, and Min-K has the largest of ZOI of all the tested insulation materials. All cal-sil, Nukon and RMI insulation is jacketed.

The updated debris generation calculations make use of two assumptions related to non-coating debris generation.

Assumption 1 Supporting members fabricated from steel shapes (angles, plates) are installed to provide additional support for insulation on equipment. It is assumed that as a result of the postulated pipe break, these supporting members will be dislodged from the equipment, and may be bent and deformed, but will not become part of the debris that may be transported to the sump.

Assumption 2 In the September 1 response it was noted that an analytical process was used that conservatively overstated the quantity of debris from insulation by 5-15%. That analytical process has been completely replaced and the debris quantity is no longer overstated. Instead, a 10% margin has been added to the cal-sil insulation volume results. In addition, a uniform factor of 1.1 is applied to the ZOI used for calculating piping insulation volumes to account for minor variances such as insulation around valves, irregularities in the as-installed configuration, etc.

The quantities of debris and destruction ZOI are provided in Table 3.b-1 below.

Table 3.b-1: Destruction ZOI and Limitina Break Comparison Debris Type Destruction Break S1 Break S2 Break S3 Break S5 ZOI (Note 1)

(Note 1)

(Note 1)

Note 1)

Fiber Insulation (Note 2 17.0 D 0.00 ft" 0.00 ft" 0.00 ft" 0.00 ft" Cal-sil (Note 3) 5.45 D 56.18 ft3 44.96 ft3 46.03 ft3 26.89 ft3 Microtherm 28.6 D 2.28 f 3 1.14 ft3 2.28 ft3 0.00 ft3 RMI (mirror) 28.6 D 12023.52 ft2 7002.33 ft 13090.12 ft2 0.00 ft2 Insulation Jacketing (Note 4) 28.6 D 2119.91 ft2 1248.42 ft2 2241.55 ft2 209.42 ft2 Coatings Qualified - Steel 4.0 D 1.10 ft3 1.10 ft3 1.10 ft3 0.20 ft Qualified - Concrete 4.0 D 2.90 ft3 2.90 ft3 2.90 ft3 0.20 ft3 Unqualified -Total N/A 5.06 ft3 5.06 ft3 5.06 ft3 5.06 ft3

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 10 of 89 Table 3.b-1: Destruction ZOI and Limitinq Break Comparison Debris Type Destruction Break S1 Break S2 Break S3 Break S5 ZOI (Note 1)

(Note 1)

(Note 1)

Note 1 Latent Debris N/A 77.22 Ibm 77.22 Ibm 77.22 Ibm 77.22 Ibm (15% fiber, 85% particulates)

Miscellaneous Debris Labels, Tags, etc N/A 35.62 ft2 35.62 ft2 35.62 ft2 35.62 ft2 Glass N/A 57.57 ft2 57.57 ft2 57.57 ft2 57.57 ft2 Adhesive N/A 0.02 ft3 0.02 ft3 0.02 ft3 0.02 ft3 Notes:

1. Break locations are discussed in the response to NRC Topic 3.a, Break Selection
2. Existing fibrous insulation was removed from areas affected by the limiting breaks by replacing it with RMI on the reactor coolant pumps and pressurizer surge line. Other potential areas exist, but none will deliver enough fiber, along with the latent fiber, to result in a thin bed effect on the strainers. The original worst case of 8.22 ft 3 of fiber for the S1 break will be used in the downstream effects calculations in Topic 3.m, Downstream Effects

- Components and Systems.

3. The cal-sil value contains an additional 10% margin.
4. This entry is the total for all jacketing. For each insulation type, the insulation jacketing ZOI is the same as the underlying insulation.

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 11 of 89 Topic 3.c: Debris Characteristics FPL Response

[RAI 35] As discussed in the staff's SE of NEI 04-07, the categories in any size distribution are related to the transport model. For the purposes of determining the strainer debris load and head loss at Turkey Point Unit 3, a single integrated transport model was not used. Instead, each debris type was addressed separately; (i.e., Reflective Metal Insulation (RMI), paint chips, particulates, and fiber). These debris specific transport analyses did not use the size distribution as part of the input. Therefore, detailed size distributions were not required or developed for the determination of the strainer debris load or head loss. The transport analysis for each debris type is discussed in the response to NRC Topic 3.e, Debris Transport.

The bulk densities that were used to ensure that the proper quantities of the surrogate materials were used in the module head loss tests (excluding chemical effects) are provided in Table 3.c-1 below.

Table 3.c-1: Bulk Densities Used For Module Tests Debris Type Bulk density Cal-sil 14.5 Ibs/ft3 Fiber 2.4 Ibs/ft3 Zinc Filler (surrogate for zinc coatings) 457 Ibs/ft3 Silicon Carbide (surrogate for coatings) 94 lbs/ft3 Microtherm 12 lbs/ft3 The technical basis for the surface areas of signs, placards, tags, tape, etc is provided in the response to NRC Topic 3.d, Latent Debris.

The specific surface area, Sv, is a parameter that is used in the NUREG/CR-6224 head loss correlation. The head loss across the strainers was determined by testing, not the NUREG/CR-6224 correlation. Therefore, the specific surface area was not calculated or used. The head loss determination is described in the response to NRC Topic 3.f, Head Loss and Vortexing.

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 12 of 89 Topic 3.d: Latent Debris FPL Response The bases and assumptions related to latent and miscellaneous debris, and the resulting quantities used for analyses and testing, have been updated since the September 1 response.

In that response it was noted that the quantity of latent debris was an assumed value in lieu of applied survey results, and that the sacrificial area for miscellaneous debris was independently estimated. Subsequently, walkdowns have been completed in the Turkey Point Unit 3 containment specifically for the purpose of characterizing latent, miscellaneous and foreign debris (labels, stickers, etc.). The results of the walkdowns are discussed below and summarized in Table 3.b-1 in the response to NRC Topic 3.b, Debris Generation/Zone of Influence (ZOI) (Excluding coatings). These walkdowns utilized the guidance of NEI 02-01 and the staff's SE of NEI 04-07.

The methodology used to estimate the quantity and composition of latent debris in the Unit 3 containment is that of the staff's SE of NEI 04-07, Section 3.5.2. Samples were collected from eight surface types; floors, containment liner, ventilation, cable trays, walls, equipment, piping and grating. For each surface type, a minimum of (4) samples were collected, bagged and weighed to determine the quantity of debris that was collected. A statistical approach was used to estimate an upper limit of the mean debris loading on each surface. The horizontal and vertical surface areas were conservatively estimated. The total latent debris mass for a surface type is the upper limit of the mean debris loading multiplied by the conservatively estimated area for that surface type, and the total latent debris is the sum of the latent debris for each surface type.

Based on the walkdown data, the quantity of latent debris in the Unit 3 containment is estimated to be 77.22 pounds. The latent debris composition is assumed to be 15% fiber and 85%

particulate in agreement with the staff's SE of NEI 04-07.

A walkdown was performed in the Unit 3 containment for the purpose of identifying and measuring the miscellaneous (foreign) debris that constitutes the sacrificial area (e.g., labels, stickers, tape, tags etc). Based on the walkdown data, the total quantity of miscellaneous debris in the Unit 3 containment is estimated to be 93.21 ft2.

The strainer system accounts for foreign materials by inclusion of 93 ft2 of sacrificial perforated plate filtration area. This area is assumed to be blocked by the foreign materials, leaving approximately 5,450 ft2 of remaining surface area to capture the remaining debris load.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 13 of 89 Tonic 3.e: Debris TransPort FPL Response

[RAI 41] In the September 1 response it was noted that debris transport would be analyzed using the computational fluid dynamics (CFD) based methodology outlined in NEI 04-07.

Instead, for the purposes of determining the strainer debris load and head loss, each debris type was addressed separately (i.e., Reflective Metal Insulation (RMI), paint chips, particulates, and fiber).

The transport models for RMI and paint chips accounted for the low approach velocities and the fact that the lower edge of the strainer disks is approximately 5 inches above the floor. The velocities required to lift materials over a curb (lift velocity) are provided in NUREG/CR-6808.

The lift velocities are 0.3 ft/sec for aluminum RMI, 0.5 ft/sec for paint chips, and 0.84 ft/sec for stainless steel RMI. The velocity under the strainer is approximately 0.1 ft/sec, and the velocity entering the strainer disks is approximately 0.02 ft/sec. These velocities are well below the velocity required to lift paint chips and RMI above a 2-inch curb, and the disks are approximately 5 inches above the floor. Therefore it is concluded that RMI and paint chips will not be transported to the strainer disks.

Although a separate calculation was not done for insulation jacketing, the same logic applies, and it is concluded that insulation jacketing will not be transported to the strainer disks.

For the remainder of the debris load it was assumed that 100% of the latent fiber, latent particulates, cal-sil, microtherm, and coating particulates are transported to the strainer disks.

The quantity of debris that arrives at the strainer modules is provided in Table 3.e-1 below.

Table 3.e-1:

Debris at Sump Strainer Modules for Limiting Case (Break S)

Constituent Quantity Generated Quantity at Strainer (From Table 3.b-1)

Fiber Insulation (Note 1) 0.00 ft3 0.00 ft3 Cal-sil 56.18 ft3 56.18 ft3 Microtherm 2.28 ft3 2.28 ft 3 RMI (Mirror) 12023.52 ft2 0 ft2 Insulation Jacketing 2119.91 ft2 0 ft2 Coatings Qualified - Steel 1.10ft3 1.10ft3 Qualified - Concrete 2.90 ft3 2.90 ft3 Unqualified -Total 5.06 ft3 5.06 ft3 Latent Debris 15% Fiber 11.58 Ibm 11.58 Ibm 85% Particulate 65.64 Ibm 65.64 Ibm Total 77.22 Ibm 77.22 Ibm Foreign Materials Labels, Tags, etc 35.62 ft2 35.62 ft2 Glass 57.57 ft 2

57.57 ft2 Adhesive 0.02 ft3 0.02 ft3 Total 93.21 ft2 93.21 ft2

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 14 of 89 Notes:

1.

Existing fibrous insulation was removed from areas affected by the limiting breaks by replacing it with RMI on the reactor coolant pumps and pressurizer surge line.

Topic 3.f: Head Loss and Vortexinq FPL Response A piping schematic of the ECCS and containment/reactor building spray systems is provided in Figure 3.f-1 below. A description of the strainer system including the capability to accommodate thin bed effects is provided in the response to NRC Topic 3.j, Screen Modification Package. However, Turkey Point Unit 3 has very little fibrous debris.

[RAI 37] [RAI 40] The entire distributed strainer system is fully submerged from the initiation of recirculation through the duration of the event. At the minimum Large Break LOCA (LBLOCA) water level the submergence of the strainer disk (which is the highest opening in the strainer system) is approximately 7.9 inches. At the minimum Small Break LOCA (SBLOCA) water level, the submergence of the strainer disks is approximately 4.1 inches.

The possibility of vortex formation at the strainer modules was evaluated by both tests and analyses. The strainer module tests were conducted at a test submergence that is less than the submergence during recirculation (- 3/2 inches for the test vs. -7.9 inches for LBLOCA and 4.1 inches for SBLOCA recirculation). No vortexing or air ingestion was observed during the testing. In addition an evaluation was conducted that doubled the approach velocity (a 100%

increase). This evaluation generated an air ingestion factor of -0.1, which, because it is much less than 1.0, indicates that air ingestion will not occur at the strainer module during operation.

[RAI 40] Vortexing at the sump ECCS/CSS suction inlets is not a concern because the strainers are piped directly to the suction inlets.

No formal analysis has been performed regarding buoyant debris circulating, on top of the sump water over the strainer modules. However, it is noted that other than latent fiber, Turkey Point Unit 3 has little or no fibrous debris, and is thus effectively immune to issues associated with buoyant fibrous debris. Further, with the highest screens submerged by a good margin, and with no vortexing possible, the potential for floating debris reaching the screens is remote.

[RAI 39] The new strainer system has a surface area of approximately 5,543 ft2, which can accommodate the maximum debris load, after transport to the strainer, from the bounding break discussed in the response to NRC Topic 3.a, Break Selection.

The total strainer system head loss is made up of two components; the strainer module head loss, and the interconnecting piping head loss. Each of these components was evaluated for two recirculation flow conditions. For the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after a LOCA, the maximum flow rate is 2,697 gpm, and after 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (> 24 hrs post-LOCA) the maximum flow rate is 3,750 gpm.

The strainer module head loss, excluding chemical effects, is based on tests that were run specifically for Turkey Point Unit 3 by General Electric at Continuum Dynamics, Inc (CDI). The tests were performed using a test module with 16 discs. The module tests simulated plant debris loads and strainer approach velocities to validate the design. The module discs were aligned vertically in the same manner as the plant strainer discs. The tests were performed

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 15 of 89 with a submergence of -31/2 inches. The strainer head loss test results were scaled to the full sized strainer system based on velocity, and bed thickness differences. The scaling process assumed that flow through the strainer internals is turbulent due to the abrupt direction changes and abrupt expansions from the strainer discs to plenum.

[RAI 36] The near-field effect was not credited in the design or tests. The steps taken to minimize near-field effects in the tests included placing the flow return near the bottom of the test tank to help suspend debris, and using six (6) motor driven agitators to ensure that all debris remained suspended. Eight (8) agitators were started prior to debris addition to facilitate mixing and prevent settling of debris prior to strainer test pump startup, and the two agitators behind the module were stopped after flow through the module was established. The materials listed in Table 3.f-1 below were used to represent the Turkey Point Unit 3 debris in the test.

The piping head losses are the hydraulic losses associated with flow through the twelve strainer plenums, interconnecting pipe and discharge piping to the ECCS pump suction inlets.

Assumptions, margins and conservatisms used in establishing the head losses are:

A maximum temperature of 300°F A minimum temperature of 65 0F A flow rate of 2,697 gpm during the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after a LOCA A flow rate of 3,750 gpm after the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after a LOCA For the piping line head loss, the flow was analyzed for both the north and south sumps and the limiting case was used Temperature/viscosity was not used to scale the results of the head loss tests to actual plant conditions

[RAI 39] The head loss for the strainer system, not considering chemical effects, is provided in Table 3.f-2 below.

Table 3.f-1:

Module Test Debris Materials Debris Type Material Density Manufacturer Fiber Transco Thermal Wrap (shredded) 2.4 lb/ft3 Transco Cal-Sil Thermo 12 Gold (pulverized) 14.5 lb/ft3 Industrial Insulation Group Inorganic Zinc Carboline Carbo-Zinc filler 457 lb/ft3 Carboline Microtherm Microtherm (pulverized) 12 lb/ft3 Microtherm, Inc.

Coating Particulates Silicon Carbide (- 10 micron dia) 94 lb/ft3 Electro Abrasives Table 3.f-2: Strainer System Head Loss Summary (Excluding Chemical Effects)

Condition Flow Rate Strainer Piping Total (gpm)

Head Loss Head Loss Head Loss (ft) ft ft Debris Laden (< 24 hrs) 2,697 0.97 1.18 2.15 Clean (< 24 hrs) 2,697

.08 1.18 1.26 Debris Laden (> 24 hrs) 3,750 1.02 2.28 3.30 Clean (> 24 hrs) 3,750

.09 2.28 2.37 For the limiting design case (lowest pool level) the existing volume of air in containment with the pressure adjusted for temperature and the vapor pressure equal to the saturation pressure of

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 16 of 89 the sump water is credited for prevention of flashing at the immediate strainer/debris bed surface. However, for the overall NPSH analysis the greater of the air pressure prior to the postulated design basis accident or the vapor pressure, not both, was used.

Turkey Point Unit 3 Docket Nos. 50-250 L-2008-138 Page 17 of 89 UNIT 4 RWST Figure 3.f-1: ECCS/CSS Piping Schematic

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 18 of 89 Topic 3..q: Net Positive Suction Head (NPSH)

FPL Response Following a large break LOCA (LBLOCA) both trains of the RHR/Low Head Safety Injection (RHR/LHSI) Pumps and High Pressure Safety Injection (HHSI) pumps are automatically started on a safety injection signal (SIS). Both Containment Spray (CS) pumps are automatically started on a containment high pressure signal (CHPS). Recirculation is initiated manually on the refueling water storage tank (RWST) low level alarm, which occurs at approximately 30 minutes after the LBLOCA. At the changeover to recirculation both RHR/LHSI pumps are manually stopped and switched over from the RWST to the recirculation sump. One RHR/LHSI pump is then manually restarted. At this point, the CS and HHSI pumps continue to draw water from the RWST although one CS pump is manually stopped. When the RWST level reaches 60,000 gallons the HHSI and CS pumps are manually stopped and aligned to take suction from the RHR/LHSI pumps ("piggyback" mode), and one HHSI pump is restarted.

Following a small break LOCA (SBLOCA) both trains of the RHR/LHSI Pumps and HHSI pumps could automatically start if an SIS is received. Both Containment Spray (CS) pumps could automatically start if a CHPS is received. If the recirculation phase is entered, suction to the safety injection pumps is provided by the RHR/LHSI pumps as in the LBLOCA. For a SBLOCA where the RCS pressure is above the RHR/LHSI shut-off head, the RHR/LHSI pumps will not deliver flow into the RCS during the injection phase. Under these conditions the time to recirculation, which is based on the RWST level, is increased beyond the LBLOCA value of approximately 30 minutes.

The range of SBLOCA breaks includes those that require recirculation from the containment sump as well as those that permit the operators to depressurize the RCS and initiate the shutdown cooling mode of decay heat removal, which does not require suction from the containment sump. Because the SBLOCA produces less debris, the debris load on the sump strainers is less than the design basis debris load. However, for the purpose of evaluating the sump strainer under SBLOCA conditions, it is conservatively assumed that the recirculation flow from the containment sump and the debris load are the same as the LBLOCA, and that the water level is that of the SBLOCA.

Contrary to the usual single failure analyses for safety analysis which are postulated to minimize overall safeguards flows, the failure mode postulates for the containment sump strainer design are most limiting when ECCS/CS recirculation flows from the post-LOCA containment pool are maximized, or when the overall available suction strainer area is minimized, thus maximizing strainer head losses and reducing the safeguards pumps overall (NPSH) margin.

The alignment of the ECCS and CS from the injection mode to the recirculation mode of operation is accomplished entirely by manual action in accordance with Emergency Operating Procedures (EOPs). A detailed single failure analyses was performed to determine the worst case single failure. The analysis considered each component action requiring manipulation or mechanical action dictated by EOPs and documented the component, the postulated failure mode, resultant outcome and net incremental recirculation flow effect. Two postulated scenarios involving valve alignment failures (RHR cold leg header isolation valves and RHR

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 19 of 89 alternate discharge isolation) were determined to be the worst case single failures. The evaluation concluded that the Turkey Point ECCS/CS recirculation strainer design flow bounds the worst case postulated single failures of this evaluation.

The minimum sump water level is 17.35 feet for the LBLOCA and 17.03 feet for the SBLOCA.

The assumptions made in the calculation for minimum containment sump level are as follows:

The initial RWST level is assumed to be at the minimum Tech. Spec. level.

The worst case instrument error is assumed.

The inventory is reduced by the equivalent water volume needed to make up the LOCA steam/air mixture.

For the large break accident the vessel is considered to be flooded, thus the volume of the vessel, RCS piping, and reactor coolant pumps is not included in the sump water.

The volume is reduced by the volume required to fill the containment spray piping.

The calculation of the water condensation film on all passive heat sink surfaces exposed to air in the containment utilizes the conservative heat sink areas. The thickness of the film is based on classic laminar film condensation calculations. Conservatively, the average thickness plus 10% was used The water held up inside containment as spray droplets was calculated utilizing the containment spray flow, the droplet fall distance, and droplet terminal velocity.

During a SBLOCA the volume of the RWST water spills to the containment floor.

A 20% margin is added to the combined length of containment spray piping to account for small bore piping and configuration differences.

The remaining net volume, after the above adjustments, was divided by the free area above 14 ft elevation to determine the minimum corresponding water height within the containment. For conservatism, the volume occupied by equipment other than the vessel and large concrete structures will not be considered.

The following table provides a summary of the water sources:

Table 3.q-1 Post-LOCA Containment Pool Water Sources Component Water Volume Sources ft3 - LBLOCA ft;

- SBLOCA Steam Generators:

2,805 N/A Pressurizer 780 N/A Accumulator Tanks 2,625 N/A Reactor Vessel 3,667 N/A RCS Piping 783 N/A Reactor Coolant Pumps 192 N/A Total volume inside containment at LOCA t=0 10,852 0

Refueling Water Storage Tank:

42,778 42,778 Total volume inside containment at initial RAS (recirculation actuation signal) =

53,630 42,778

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 20 of 89 The LBLOCA sump flow rates used to calculate the NPSH margin are 2697 gpm for the period prior to 24 hrs and 3750 gpm after 24 hrs, which are the same as those used to determine the strainer system head loss discussed in the response to NRC Topic 3.f, Head Loss and Vortexing. In recirculation mode, the CS and HHSI pumps operate in "piggyback" mode on the RHR/LHSI pumps. Therefore they are already included in the RHR/LHSI pump flow.

The temperature ranges used to calculate the NPSH margin are 65 °F to 300 OF for the period prior to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, and 65 OF to 170 OF for the period after 24 hrs. The minimum NPSH margin occurs at a temperature of approximately 200 OF.

Under these conditions, the minimum NPSH margin, excluding chemical effects, is approximately 6.1 feet for the LBLOCA and 5.8 ft for the SBLOCA. The minimum NPSH margin, including chemical effects, is approximately 3.4 feet for the LBLOCA and 3.1 feet for the SBLOCA. The key assumptions are listed below.

Containment accident pressure is consistent with Regulatory Guide 1.1 guidance (i.e., at lower temperatures, when the vapor pressure of water is less than the partial pressure of air, the total containment pressure is set equal to the minimum partial pressure of air and is not increased; at higher temperatures when the vapor pressure of water is greater than the minimum partial pressure of air, the total containment pressure is set equal to the vapor pressure of water.)

NPSH required (NPSHR) is based on pump test curves The debris only strainer head loss was determined by testing.

The chemical testing program and the application of a "bump up factor" to account for the impact of chemical effects on NPSH is discussed in Topic 3.o, Chemical Effects.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 21 of 89 ToDic 3.h: Coatinas Evaluation FPL Response At Turkey Point Unit 3, coatings are classified as qualified/acceptable, or unqualified. The qualified/acceptable coating systems used in the Turkey Point Unit 3 containment are listed in Table 3.h-1 below.

Table 3.h-1 Qualified/Acceptable Coatings in the Turkey Point Unit 3 Containment Substrate Application Coating Application Product Thickness (mils)

Steel 1st Coat Carboguard 890 6

2nd Coat Carboguard 890 6

1st Coat (Note 1)

Carbozinc 11 4.5 2nd Coat (Note 1)

Phenoline 305 5

Concrete Floor 1st Coat Carboguard 2011S 50 2na Coat Carboguard 890 7

3rd Coat Carboguard 890 7

1st Coat (Note 1)

Phenoline 305 4.5 Concrete Primer 2nd Coat (Note 1)

Phenoline 305 4.5 Concrete Wall 1st Coat Carboguard 2011S 35 2nd Coat Carboguard 890 7

3rd Coat Carboguard 890 7

Concrete Wall 1st Coat (Note 1)

Phenoline 305 4.5 Concrete Primer 2nd Coat (Note 1)

Phenoline 305

4.5 Notes

1. Specified thickness for original coatings. Repaired coatings are thicker, and the debris generation is based on the maximum coating thicknesses of the repair coatings.

[RAI 30] For Turkey Point Unit 3, the fiber is that contributed by latent debris, i.e., 11.58 Ibm (15% of 77.2 Ibm). ElectroCarb black silicon carbide was used as a surrogate for coatings other than inorganic zinc. ElectroCarb has a 10-micron diameter, which is the limiting particle size for head loss per NEI 04-07, and has a density similar to the qualified and unqualified coatings in Table 3-3 of NEI 04-07. As discussed in the response to NRC Topic 3.e, Debris Transport, coating chips will not be transported to the strainer disks. Carboline Carbo-zinc filler was used as the surrogate for inorganic zinc because it is the principal constituent.

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 22 of 89 Selected features of the treatment of qualified and unqualified coatings in the determination of coating debris that reaches the sump strainers have been updated since the September 1 response. These changes are discussed individually below.

[RAI 29] The qualified coating ZOI in the September 1 response for Turkey Point Unit 3 was 1OD. The ZOI for qualified coatings has subsequently been reduced to 4D. The 4D ZOI is based on testing that was completed at the St. Lucie Plant during February of 2006.

A description of the test, the test data, and the evaluation of the test data, were previously provided to the NRC staff for information on July 13, 2006 in FPL Letter L-2006-169 (R. S.

Kundalkar (FPL) to M.G. Yoder (NRC), "Reports on FPL Sponsored Coatings Performance Tests Conducted at St. Lucie Nuclear Plant," July 13, 2006 ). The evaluation of the test results confirms that a 4D ZOI is applicable to the in-containment qualified coating systems at Turkey Point Unit 3. As stated in the test plan, heat and radiation increase coating cross linking, which tends to enhance the coating physical properties. Therefore, since artificial aging, heat, or irradiation to the current plant conditions could enhance the physical properties and reduce the conservatism of the test, the test specimens were not aged, heated, or irradiated.

The coating thicknesses in the September 1 response were assumed to be 3 mils of inorganic zinc primer plus 6 mils of epoxy (or epoxy-phenolic) top coat for qualified coatings, and 3 mils of inorganic zinc (IOZ) for unqualified coatings. Subsequently, the analyses have been updated.

The current debris generation model conservatively assumes the maximum thicknesses for each applicable coating system.

The coating area in the ZOI in the September 1 response was assumed to be equal to the surface area of the ZOI. Subsequently, the updated debris generation calculations calculate the quantity of qualified coatings for each break by using the concrete and steel drawings to determine the amount of coating that will be within the ZOI for each break. Coatings that are shielded from the jet by a robust barrier are not included in the total. The calculated volume of qualified steel coating is then increased by 10% to account for small areas of additional items such as piping, pipe/conduit/HVAC/cable tray supports, stiffener plates, ladders, cages, handrails and kick plates.

The estimated quantity of unqualified/failed coatings in the September 1 response was 6 ft3.

With the changes discussed above, the total quantity of unqualified/failed coatings is now 9.06 ft3.

Subsequent to the September 1 response, the process for controlling the quantity of degraded qualified coatings in containment has been enhanced to ensure that it does not exceed the sump strainer design basis.

The previous program for controlling in-containment coatings was described in the FPL response to NRC Generic Letter 98-04, "Potential for Degradation of the Emergency Core Cooling System and the Containment Spray System After a Loss-of-Coolant Accident Because of Construction and Protective Coating Deficiencies and Foreign Material in Containment" in letter L-98-272 on November 9, 1998. The letter summarized the program in place at that time for assessing and documenting the condition of qualified/acceptable coatings in the primary containment at Turkey Point Unit 3.

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 23 of 89

[RAI 25] The current program for controlling the quantity of unqualified/degraded coatings includes two separate inspections by qualified personnel during each refueling outage, and notification of plant management prior to restart if the volume of unqualified/degraded coatings approaches pre-established limits.

The first inspection takes place at the beginning of every refueling outage, when all areas and components from which peeling coatings have the potential for falling into the reactor cavity are inspected by the FPL Coating Supervisor. The second inspection takes place at the end of every refueling outage when the condition of containment coatings is assessed by a team (including the Nuclear Coating Specialist) using guidance from EPRI Technical Report 1003102

("Guidelines On Nuclear Safety-Related Coatings," Revision 1, (Formerly TR-1 09937)).

Accessible coated areas of the containment and equipment are included in the second inspection. Plant management is notified prior to restart if the volume of unqualified/degraded coatings approaches pre-established limits.

The initial coating inspection process is a visual inspection. The acceptability of visual inspection as the first step in monitoring of Containment Building coatings is validated by EPRI Report No. 1014883, "Plant Support Engineering: Adhesion Testing of Nuclear Coating Service Level 1 Coatings," August 2007. Following identification of degraded coatings, the degraded coatings are repaired per procedure, if possible. For degraded coatings that are not repaired, all areas of coatings determined to have inadequate adhesion are removed, and the Nuclear Coatings Specialist assesses the remaining coating to determine if it is acceptable for use.

The assessment is by means of additional nondestructive and destructive examinations as appropriate.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 24 of 89 Topic 3.i: Debris Source Term FPL Response Information related to programmatic controls for foreign materials was provided to the NRC in previous submittals. Such information was provided in letter L-2003-201 which responded to NRC Bulletin 2003-01, and most recently in letter L-2005-181 which responded to GL 04-02. In general, the information related to programmatic controls that was supplied in these responses remains applicable. However, since the September 1 response, modifications, tests and walkdowns have been completed and these have been used to inform and update the programmatic controls that support the new sump strainer system design basis.

The results of the recently completed walkdowns to assess the quantities of latent and miscellaneous debris are discussed in the response to NRC Topic 3.d, Latent Debris. These walkdowns were conducted without any preconditioning or pre-inspections. Consequently, the debris found during the walkdowns is characteristic of approximately 33 years of operation under the existing housekeeping programs. Given the small quantity of latent and miscellaneous debris after 33 years of operation under the current housekeeping program, it is concluded that the current housekeeping program is sufficient to ensure that the new strainer system design bases will not be exceeded.

Currently insulation and materials inside containment are controlled by procedures that require:

(a) a review of changes to insulation or other material inside containment that could affect the containment sump debris generation and transport analysis and/or recirculation functions and (b) a review of the effect of a change package for its impact on containment sump debris generation and transport. This guidance has been enhanced by updating the engineering specification that controls insulation configuration with the insulation information that was obtained for the debris generation and transport calculations via walkdowns during outages PT3-19 and PT3-20.

Detailed containment cleanliness procedures exist for unit restart readiness and for containment cleanliness prior to entry into Mode 4. These procedures incorporate the industry guidance of Nuclear Energy Institute (NEI) 02-01, Revision 1 to minimize miscellaneous debris sources within the containment. The requirements to assure that the containment is free of loose debris and fibrous material, and that items not approved for storage in the containment are removed, are specifically addressed. Detailed containment sump inspections are performed at the end of each outage. Plant procedures also require that the Site Vice President and the Plant General Manager perform a walkdown of the containment prior to entry into Mode 4 at the end of each refueling outage to ensure plant readiness.

One new procedure has been written for inspection of the new strainer system, and the containment close-out procedure has been updated. The new procedure requires that there are no holes or gaps greater than 3/32 inch (0.09375 inch) in the strainers. The new procedure includes all of the new strainer system components in the final containment closeout inspection.

Note that programmatic controls related to coatings are provided in the response to NRC Topic 3.h, Coatings Evaluation.

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 25 of 89 The second debris source term refinement discussed inSection 5.1 of NEI 04-07, "change-out of insulation", was utilized to improve the debris source term. Three (3) insulation modifications were completed that reduced the quantities of fibrous and particulate debris that could be transported to the sump strainers. The first modification replaced the Nukon and cal-sil insulation on the Pressurizer Surge Line with reflective metal insulation (RMI). The second modification replaced the coated blanket insulation on the Reactor Coolant Pumps with RMI.

The third modification completely removed the insulation from the Pressurizer Relief Tank (PRT).

In accordance with 10 CFR 50.65 (Maintenance Rule), PTN-3 maintenance activities (including associated temporary changes or temporary system alterations) are controlled by plant procedure. This process maintains configuration control for non-permanent changes to plant structures, systems, and components while ensuring the applicable technical reviews and administrative reviews and approvals are obtained. If, during power operation conditions, the temporary alteration associated with maintenance is expected to be in effect for greater than 90 days, the temporary alteration is subject to the requirements of 10 CFR 50.59 prior to implementation.

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 26 of 89 Topic 3.i: Screen Modification Package FPL Response The original sump screens have been completely replaced with a single, non-redundant, distributed sump strainer system that consists of twelve (12) modules combined into four (4) assemblies and interconnecting piping, and increases the surface area to approximately 5,543 ft2. The strainer system uses the General Electric discreet modular stacked disc strainers.

[RAI 32] The new strainer system is completely passive (i.e., it does not have any active components or rely on backflushing).

As in the original design, the new distributed strainer system serves both ECCS suction intakes.

The original ECCS intake design has a permanent cross-connection downstream of the containment ECCS sump inlets (outside the containment), which permits either train to draw from both ECCS sump inlets. The new strainer design provides a pathway inside the containment that is parallel to the original cross-connection. Because the original Turkey Point Unit 3 design contained this ECCS cross-connection, the new design is not a departure from the existing design basis. It is consistent with the current design basis, Technical Specifications and regulatory commitments for Turkey Point Unit 3. The new strainer system is sized for the full debris load and full ECCS flow from the ECCS/CSS systems. Design basis flow is discussed in the response to NRC Topic 3.f: Head Loss and Vortexing. Because a single non-redundant strainer system is used, the system has been designed such that there is no credible passive failure mechanism that could render both ECCS trains inoperable. Active strainer failure mechanisms are not considered because the strainer system is completely passive. The strainer system structural design is discussed in the response to NRC Topic 3.k, Sump Structural Analysis.

The strainer modules consist of a series of vertically oriented rectangular discs, stacked in parallel along a horizontal axis, that have exterior debris capturing surfaces of perforated plate covered with woven wire mesh. The wire mesh decreases the head loss across the strainer plates by breaking up debris beds. Each strainer disc is constructed of two plates and has an open interior to channel disc flow toward the strainer plenum. The discs are mounted on a frame and to the discharge plenum on the side of the disc set which channels disc flow to the interconnecting suction piping. Stainless steel is used as the material of construction.

The quantity of fibrous debris available for transport is not sufficient to produce a 1/8-inch thick debris bed. Nevertheless, the debris plate and the small pitch between disks allow the strainer to mitigate thin bed effects should they occur.

The strainer perforations are nominal 3/32-inch diameter holes. This is an enhancement from FPL's statement in the September 1, 2005 submittal, where the stated expectation was only that the perforation size would be less than 1/8-inch by 1/8-inch square opening (that is, the current opening size is 93.75 mils, while the initial postulated square opening had a diagonal dimension of 176.78 mils.).

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 27 of 89 The modules in each assembly are tied together into larger units by a connected common plenum. The strainer plenums are connected together and to the ECCS suction inlets by the strainer piping.

Fabrication and installation tolerances of all equipment are such that debris larger than 0.1031 inch (110% of nominal opening diameter) cannot bypass the strainer system. Therefore, debris retention capacity of the entire system is at least as good as the strainer modules.

The entire strainer system is designed and situated to be fully submerged at the minimum containment water level during recirculation. During flood-up water would fill the strainer system from the bottom up, forcing air out of the perforated strainer discs, thereby venting the system. Because the discs are below the containment water level prior to the start of recirculation, air will not be sucked in through the perforated discs. Because the strainers vent the system prior to the start of recirculation, no other venting is required.

The capability of the strainer system to accommodate the maximum mechanistically-determined debris volume has been confirmed by a combination of testing and analysis. The volume of debris at the screen is discussed in the response to NRC Topic 3.c, Debris Characteristics. The capability to provide the required NPSH with this debris volume is discussed in the response to NRC Topic 3.g, Net Positive Suction Head (NPSH). The capability to structurally withstand the effects of the maximum debris volume is discussed in the response to NRC Topic 3.k, Sump Structural Analysis.

Two additional modifications were completed that are not directly related to the requirements of GL 2004-02. The first of these modifications created a cylindrical core bore 15/2 feet long with a 16-inch diameter beneath the refueling cavity (also known as the fuel transfer canal) to provide a pathway for the piping that connects the strainer assemblies to the south ECCS sump suction inlet.

The second modification filled the existing ECCS sump suction inlet pits with reinforced concrete. At Turkey Point Unit 3, the ground floor of the containment acts as a sump pool, and the ECCS pumps take suction from this pool via two inlet lines that are set into the containment floor on the 14-foot elevation. The piping from the new strainers is connected directly to the ECCS suction inlet piping. Therefore, the existing ECCS sump pits no longer provide any benefits.

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 28 of 89 Topic 3.k: Sump Structural Analysis FPL Response The previous sump strainer system has been completely replaced by a new strainer system.

The new system is passive and does not utilize backflushing. It is described in the response to NRC Topic 3.j, Screen Modification Package. Assurance that strainer system is inspected for adverse gaps or breaches prior to concluding an outage is discussed in the response to NRC Topic 3.i, Debris Source Term.

There are four (4) strainer assemblies in the system. Each assembly consists of multiple strainer units bolted together. There are three (3) major subcomponents: passive strainer assemblies, strainer piping, and pipe supports. The pipe runs that connect the strainer assemblies and ECCS/CSS suction inlets are nominal 14-inch stainless steel, schedule 10S, and utilize flexible bellows connections to allow for thermal expansion. The assemblies are connected to the south ECCS/CSS suction inlet by piping that runs through a cylindrical core bore 15Y feet long with a 16-inch diameter beneath the refueling cavity (also known as the fuel transfer canal). The piping that connects to both the north and south ECCS/CSS suction inlets is embedded in concrete within the sumps so that negligible loads are imposed on the ECCS/CSS suction piping.

The NSSS system is located between a bioshield near the outer wall of containment and a primary shield that surrounds the reactor cavity. The bioshield is a two-piece wall with one wall starting at the floor and extending upwards, and the other starting at the ceiling and extending down. The two walls are offset so that they do not intersect, which creates an opening between them due to their overlap. This opening provides a clear path for jet impingement on piping outside the bioshield by breaks inside the bioshield (or vice versa) in certain instances. An evaluation of potential breaks and potential targets in both the inner annulus and the outer annulus was performed. The evaluation concluded that the effect of the opening is negligible.

The system only operates once the containment is filled with water and the entire system is fully submerged. The system is also designed to vent during containment flood up, and there is no requirement to be leak tight. That is, the strainers and piping are not pressure-retaining vessels, but rather are required to guide the screened water to the pump suction lines while fully submerged. However, the strainers and associated piping have been designed to withstand a maximum differential pressure of 20 psi. The maximum debris only head loss experienced by the strainers is 1.54 psi, which is much less than the design strength for maximum differential pressure.

The strainer module structural loads and load combinations are summarized in Tables 3.k-1 and 3.k-2 below. The strainer module structural qualification results are summarized in Table 3.k-3 below. Finite element analyses were performed for all components of the strainer module assembly using the ANSYS program. The strainer modules were designed using ASME Section III, Subsection NC Class 2 (components) and Subsection NF (supports) as a guide.

The capability of the strainer perforated plate discs as structural members was calculated, using the equivalent plate approach which is contained in the ASME B&PV Code,Section III, Appendix, Article A-8000. For the concurrent events of a LOCA, seismic event, and the strainer

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 29 of 89 modules fully clogged, the strainer discs were designed to ASME Section III Subsection NCA-2142, Level D allowable stresses.

The connecting piping was analyzed using Sargent & Lundy computer program PIPSYSW.

The connecting piping was designed and analyzed in accordance with ASME III Subsection NC (Class 2 components). The analyses confirmed that the pipe stresses are below the Code allowable limits.

The piping supports were designed to AISC with allowable stresses based on the AISC manual of Steel Construction, 13th Edition. In all cases the loads were applied in the direction that generated the maximum stress levels, and the analyses confirmed that the supports met the acceptance criteria.

The 16-inch diameter core bore was analyzed for its effect on the structural integrity of the concrete wall that it penetrates. The only affected component is the concrete wall that contains the core bore. The analysis confirmed that the concrete wall with the core bore continues to meet the design basis requirements with margin. Subsequent to drilling the 16-inch diameter concrete core, the penetration was coated to protect the cut ends of steel reinforcement from corrosion.

With regard to trash racks, the design is robust and the trash rack function is incorporated into the design. Separate (distinct) trash racks are not required. This is consistent with the original Turkey Point Unit 3 strainers/sumps, which did not have separate trash racks.

The new strainer system is described in the response to NRC Topic 3.j, Screen Modification Package. Assurance that there are no adverse gaps or breaches that could allow larger debris to bypass strainer system is discussed in the response to NRC Topic 3.i, Debris Source Term.

Table 3.k-1: Strainer Structural Loads and Load Combinations Load Load Combination 1

D+L +Ej 2

D+L'+E 2 3

D+L+ T + E1 4

D+L'+T + E2 5

D+L +T

+ E',

6 D+L +TA 7

D+L'+TA + E' 2 + PCR Table 3.k-2: Structural Load Symbols Symbol Load Definition D

Weight of Dry Strainer Assembly L'

Water Weight + Debris Weight + Hydrodynamic Mass L

Live Load, 250 Pound Person T

Normal Operating Thermal Load TA Accident Thermal Load El Earthquake Load, OBE in air

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 30 of 89 Table 3.k-2: Structural Load Symbols Symbol Load Definition E2 Earthquake Load, OBE in water E',

Earthquake Load, SSE in air E' 2 Earthquake Load, SSE in water Pcr Differential (Crush) Pressure S

The Limit, S, is the section strength based on elastic design methods and allowable stresses defined in AISC Specification Part 1, Manual of Steel Construction Allowable Stress Design, 9th Edition, 1989 Sy ASTM minimum yield strength Table 3.k-3: Strainer Structural Load Stress Ratio Results Load Combination (Note 1) 4 7

Allowable Stress Sy Sy or 2.4S (Note 2)

Stress Ratio Plenum Support Plate 1.01 1.37 Plenum Support Frame 1.33 1.79 14 inch pipe 1.05 1.4 Pipe run Connection Plate 1.54 2.08 Plenum Side Cover 28 Disks 1.11 1.46 Plenum Flange 4.38 5.92 Foot Top Plate 5.51 6.42 Plenum Inspect Plate 3.49 4.69 Foot Base Plate 15.08 19.59 Foot 1.68 2.18 Plenum Support Block 5.60 7.33 Angle Bracket 1.08 1.22 Plenum Body 2.35 3.15 1" Angle Support Plate 12.55 13.97 Notes:

1. Load combinations 4 and 7 were bounding, and therefore were the only loads that were analyzed.
2. The higher limit is based on ASME Sub-section NF, Appendix F. The higher limit only applies to the disks (all parts).

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 31 of 89 Topic 3.1: Upstream Effects FPL Response In the September 1 Turkey Point response it was noted that the refueling canal drains required further evaluation to determine if they constituted potential choke points. Subsequent to the September 1 response, a walkdown was conducted in the Turkey Point Unit 3 containment specifically to evaluate ECCS recirculation flow paths. The walkdown utilized the guidance in Nuclear Energy Institute (NEI) Report 02-01, NEI Report 04-07 and the staff's SE of NEI 04-07.

[RAI 38] The information obtained during the walkdown confirmed that the only potential choke points are the fuel transfer canal drain covers at the bottom of the refueling canal. The drain covers are intended to prevent items from falling into the drains during refueling operations.

There are 2 drain lines in the refueling cavity.

These drains are 6 inches in diameter and as such any debris that would reach the lower cavity is expected to drain through this large line provided the covers are removed. Therefore, the potential choke points have been eliminated by updating the containment closeout procedure to ensure that the drain covers are removed prior to restart. The procedure changes are described in the response to NRC Topic 3.i, Debris Source Term.

Other specific NEI and NRC concerns that were addressed in the walkdown are itemized below.

Choke points will not be created by debris accumulating on access barriers (fences and/or gates).

" Choke points will not be created by debris accumulation in narrow hallways or passages.

No curbs or ledges were observed within the recirculation flow paths. At the upper elevations, concrete slabs smoothly transition to grating or open space without any contiguous curbs.

No potential choke points were observed at upper elevations, including floor grates, which would be expected to retain fluid from reaching the containment floor.

" The containment floor was surveyed for choke points formed by equipment, components, and other obstructions. While some debris hold up may occur, it will not prevent water from reaching the sump strainers.

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 32 of 89 Topic 3.m: Downstream Effects - Components and Systems FPL Response In the September 1 response it was noted that, at that time, the downstream evaluations identified instrumentation and seventeen (17) components that required further evaluation.

Subsequently, the strainer opening size has been reduced from an assumed opening of 1/8-inch by 1/8-inch (diagonal dimension of 0.177-inch) to an installed opening of 3/32-inch diameter (0.09375 inch), and the quantity of insulation debris available for transport has been reduced.

The analysis of downstream effects at PTN-3 primarily follows that set forth in WCAP-16406-P, Revision 1. A summary of the application of those methods is provided below with a summary and conclusions of the downstream effects calculations performed. Any exceptions or deviations from the NRC-approved methodology are noted below. The methodology, summary, and conclusions are provided as related to downstream component blockage and wearing, the subjects addressed by Topic 3.m. The Turkey Point Unit 3 responses to the NRC staff's Limits and Conditions related to the staff review of WCAP 16406-P are provided in Enclosure 1.

Blockage/Plugqging of ECCS and CSS Flowpaths and Components GL 2004-02 Requested Information Item 2(d)(v) addresses the potential for blockage of flow restrictions in the ECCS and CSS flowpaths downstream of the sump screen, while item 2(d)(vi) refers to plugging of downstream components due to long-term post-accident recirculation.

The difference in requirements is that blockage refers to the instantaneous blockage of flowpath components due to the maximum debris size that passes the recirculation sump filtration system, as compared to plugging which can result from the settling of any size debris in downstream components long-term. The evaluations performed for downstream components at PTN-3 considered both blockage and plugging as required for a particular component type, although the terminology was used interchangeably in the evaluations. The following summarizes the evaluation of downstream components that was performed at PTN-3, using the blockage and plugging terminology consistent with the GL 2004-02 Requested Information Item.

As part of the resolution for GSI-191, the existing sump screen system was removed and replaced with General Electric (GE) stainless steel modular sump strainers. Following the installation, the nominal strainer opening size has been reduced from a 1/4 in. nominal square opening (diagonal dimension of 0.354 in.) to a nominal round opening of 3/32 in. diameter (0.09375 in.). The new strainer system is described in the response to NRC Topic 3.j, Screen Modification Package.

GL 2004-02 Requested Information Item 2(d)(v) requires that the licensee state "the basis for concluding that adverse gaps or breaches are not present on the screen surface." The inspection procedure to ensure that adverse gaps or breaches are not present on the screen surface is described in NRC Topic 3.i, Debris Source Term.

WCAP-16406-P Section 5.5 provides assumed particle dimensions for recirculation debris

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 33 of 89 ingestion based on sump screen hole dimensions. Rather than the WCAP-16406-P suggested asymmetrical dimensions, the PTN-3 downstream components were analyzed for blockage based on a maximum 0.125 in. spherical particle. The actual maximum spherical size particulate debris that can pass through the strainer system and into the ECCS and CSS recirculation flowpaths is documented as 0.1031 in.

All ECCS and CSS downstream components that see active flow during recirculation (including control valves, orifices, flow elements, containment spray nozzles, and heat exchanger tubes) were analyzed for blockage due to this maximum particulate debris size. All flowpaths that could see recirculation flow per the plant design basis were considered. In accordance with the WCAP-16406-P methodology, the minimum clearance dimension within the component was checked to ensure it is larger than 0.125 in. The results of that analysis are summarized below.

Where necessary, low-flow components and piping were analyzed for plugging due to settling, as described below. Finally, static instrument sensing lines, relief valves, and check valves required to close during recirculation were analyzed for potential debris interference as discussed below.

Control Valves WCAP-1 6406-P Section 7.3 lists possible failure modes for valve types that can be expected in the recirculation flowpaths. The SER Section 3.2.5 notes that this list is comprehensive and acceptable for general use, but notes that it is not all-inclusive. In accordance with the SER recommendation, all valves in all possible recirculation flowpaths were considered and found to be of standard types as listed in WCAP-1 6406-P Section 7.3. Every recirculation control valve was compared to the general criteria in WCAP-16406-P Table 8.2-3; any valve requiring further evaluation for plugging per WCAP-1 6406-P Section 8.2.4 was identified, including all throttled valves (globe, needle, and butterfly) and globe and check valves less than 1.5 in. nominally.

The minimum flow clearance through these valves was determined from vendor drawings, and for any throttled valves based on the subcomponent dimensions and lift settings. This minimum flow clearance was compared to the cross-sectional area of a 0.125 in. sphere to ensure that blockage would not occur. The WCAP-16406-P does not require analyzing valves for debris settling. In general, control valves see higher flow velocities then the pipe leading to them, and therefore the valves were not checked for debris settling where the pipe velocity was sufficient (see below).

Root valves and other valves in static instrument sensing lines were analyzed with those instrument lines as discussed below. Relief valves were analyzed for interference as discussed below. Check valves that open but then may require closing during recirculation were also checked for possible interference issues as identified in WCAP-16406-P Table 7.3-1. This could occur where low flow causes debris settling around the valve seat while open, and then the debris prevents proper closure when the check valve should close. In accordance with WCAP-1 6406-P guidance, a flow velocity of 0.42 ft/s was considered sufficient to prevent debris settling and thereby preclude interference with proper valve closure. The flow velocity for settling was determined from the larger flow area of the nominal pipe size leading to the valve.

Because all flow clearances were sufficiently large to preclude blocking and flow velocities are fast enough to preclude plugging and interference, all control valves at PTN-3 were found to be

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 34 of 89 acceptable with respect to blockage and plugging during recirculation. Again, relief valves and instrumentation root valves were addressed separately as discussed below.

Relief Valves Relief valves on the recirculation flow paths were also considered for interference issues.

Here, the maximum pressure in the primary line during recirculation operation was conservatively determined based on maximum containment pressure, pump shut-off heads, and no line losses. Where the relief valve set pressure was higher than this pressure, it was determined not to open during recirculation and therefore debris interference was not an issue.

If a relief valve could potentially open, then blockage and the effects of debris interference with closure would be considered. This was not applicable to PTN-3 because all relief valves were found not to be subject to opening during recirculation.

Heat Exchangers All heat exchangers that see recirculation flow were also considered for blockage and plugging.

This included both the major heat exchangers as well as those in the pump seal subsystems that see debris-laden flow. In accordance with WCAP-16406-P Section 8.3.1, the inner diameter of tubes was compared to the maximum assumed particle size. In accordance with the SER Section 3.2.6, the heat exchanger tubes were also checked for plugging due to settling within the tubes, by comparing the minimum average flow velocity in the tubes to the WCAP-16406-P settling velocity (0.42 ft/s). All heat exchangers were found to be acceptable with respect to blockage and plugging.

Orifices, Flow Elements, Spray Nozzles All orifices, flow elements, and spray nozzles in the ECCS and CSS recirculation flowpaths were checked for blockage. In accordance with WCAP-16406-P Section 8.4, the minimum flow clearance of each was compared to the maximum assumed particle size. All orifices, flow elements, and spray nozzles were found to be acceptable with respect to blockage. The WCAP-1 6406-P does not suggest analyzing orifices, flow elements, and spray nozzles for debris settling.

In general, orifices, flow elements, and spray nozzles see higher flow velocities then the pipe leading to them, and therefore were not checked for debris settling where the pipe velocity was sufficient (see below).

Instrumentation Lines All instrumentation branch lines on the ECCS and CSS recirculation flow paths were analyzed for blockage and plugging. WCAP-1 6406-P Section 8.6 generically justifies static flow (water-solid) sensing lines on the basis of minimum expected flow velocities compared to debris settling velocities. However, the PTN-3 review of instrument lines was plant specific. First, the actual orientation of each instrument line was determined. Water-solid sensing lines oriented horizontally or above are considered not susceptible to debris settling into the lines. For any instrument lines oriented below horizontal, the actual minimum flow velocity through the header line at the point of the branch was determined. This velocity was compared to the WCAP-16406-P bounding settling velocity of 0.42 ft/s, as opposed to the lower debris-specific settling velocities listed in WCAP-16406-P Table 8.6-1. This approach is consistent with the

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 35 of 89 recommendation of the SER to WCAP-1 6406-P. All sensing lines were found to be acceptable with respect to plugging due to debris settling. Because the lines are water-solid, they are not susceptible to direct blockage due to large debris flowing into the lines.

Any sampling lines on the ECCS and CSS recirculation flowpaths that are required by plant procedure to be used post-accident were also considered. The sampling lines were analyzed as any other flow path when opened to take a sample: blockage and plugging of the tubing and each component was considered. The orientation of each sampling line was also checked, like an instrument line, to ensure it was not susceptible to settling of debris into the line when water-solid. All sampling lines were found to be acceptable.

Per the guidance of WCAP-1 6406-P Section 8.6.10, the PTN-3 RVLIS design was compared to the generic designs reviewed and deemed acceptable by the WCAP-16406-P. The plant design was found to be consistent, and therefore it is expected to be acceptable with regards to recirculation operation. However, the SER Section 3.2.6 notes that "evaluation of specific RVLIS design and operation is outside the scope of this SE and should be performed in the context of a licensee's reactor fuel and vessel evaluations." This is discussed in Enclosure 1, L

&C 19.

Piping The WCAP-1 6406-P does not require evaluation of piping for potential blockage or plugging.

However, in accordance with the SER Section 3.2.6, ECCS and CSS system piping was evaluated for potential plugging due to debris settling. As stated above, control valves in the ECCS and CSS lines were checked to ensure debris settling does not interfere with valve movement. The valves were checked using the flow area of the pipe in which the valves are installed. Therefore, the evaluation for control valves was used to validate that settling will not occur in the system pipes generally. It was verified that the analysis of control valves included valves in all lines in the ECCS and CSS used for recirculation, so that local flow velocities of the various line sizes and flow rates in the PTN-3 ECCS and CSS were all considered. As with other settling reviews, the minimum expected system flow rates in each line were used to minimize the flow velocity. The average velocity was determined for each pipe size based on the specific flow rate in that line and compared to the bounding settling velocity of 0.42 ft/s. All valve locations, and therefore all lines, were found acceptable with respect to plugging. Piping was not considered specifically for blockage because flow restrictions in the lines are more limiting with respect to minimum flow clearance.

Pumps The WCAP-16406-P addresses two concerns with regard to debris blockage or plugging. First, Section 7.2 states that debris in the pumped flow has the potential of blocking the seal injection flow path, or limiting the performance of the seal components due to debris buildup in bellows and springs. A review of the PTN-3 ECCS and CSS pump seals in accordance with the WCAP-16406-P methodology determined that the HHSI and LHSI pumps have seal injection arrangements using only recirculated seal cavity fluid. This precludes blockage of the seal injection flow path and the injection of debris laden post-LOCA fluids into the seal cavity chamber so that sump debris will not enter the seal chamber and will not impact the operation of seal internal components. The CS pump seals have a seal cooling system relying on

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 36 of 89 process water with a cyclone separator. Although WCAP-16406-P recommends removing cyclone separators, consistent with SER Section 3.2.5 a plant-specific review of CS pump operation was performed. The evaluation determined that the CS pump seal injection system using injected process fluid would not result in blockage of the seal injection flow path and is acceptable Further, the SER Section 3.2.6 disagreed with a WCAP-16406-P statement that seal failure due to debris ingestion is considered unlikely, because the WCAP-1 6406-P statement was founded upon only a single test. However, since the PTN-3 HHSI and LHSI pump seals use only recirculated seal cavity fluid in the spring and bellow areas of the seal that were identified as a concern, the SER Section 4.0 limitation expressing concern with this WCAP-16406-P statement is not applicable. Again, plant evaluation of the CSS pump seal water arrangement found it acceptable for continued use. Otherwise, the SER endorses the mechanical seal analysis recommended by the WCAP-16406-P with respect to debris interference.

WCAP-1 6406-P Section 7.2.3 further states that running clearances of 0.010 inch on the diameter could be clogged when exposed to pumpage with 920 PPM and higher debris concentration from failed containment coatings. It states that as a consequence of the clogging, a packing type wear pattern was observed on the rotating surface. This clogging of running clearances creates asymmetrical wear, but was not identified as having a negative impact on pump performance aside from increased wearing (which was considered as discussed below). Also, the WCAP-16406-P states that shaft seizure due to packing debris build-up is unlikely. The SER Section 3.2.5 also endorses this WCAP-16406-P guidance.

No other areas of concern for debris plugging or blockage within ECCS and CSS pumps were identified by either the WCAP-1 6406-P or the SER. Wear analysis of the pumps due to debris-laden water in close-tolerance running clearances, including packing type debris build-up, was considered as discussed below.

Conclusion (Blockage/PlucQing)

As summarized above, analysis of all lines and components in the recirculation flowpaths at PTN-3 determined that there is no potential for either debris blockage or long-term plugging, which would threaten adequate core or containment cooling.

Wearinq of ECCS and CSS Recirculation Flowpath Components GL 2004-02 Requested Information Item 2(d)(vi) concerns excessive wear of ECCS and CSS recirculation components due to extended post-accident operation with debris-laden fluids. All ECCS and CSS downstream components that see active flow during recirculation (including pumps, control valves, orifices, flow elements, containment spray nozzles, piping, and heat exchanger tubes) were analyzed for wear due to an analytically determined bounding debris load for the full recirculation mission time. All flowpaths that could see recirculation flow per the plant design basis were considered.

The evaluation of long-term wearing of ECCS and CSS recirculation components was performed for a 30-day period following initiation of recirculation post-LOCA. The 30 days period is consistent with the SE of NEI 04-07, WCAP-16406-P, and the PTN-3 UFSAR. All components were analyzed for a full 30 days of operation, unless plant specific procedures and

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 37 of 89 system configurations established a shorter maximum duration of operation. WCAP-16406-P Section 4.2 provides guidance for reducing mission times outside of plant licensing basis for components that are predicted to fail due to recirculation wear. However, consistent with SER Section 3.2.2, only plant-specific component mission time input in accordance with design and licensing basis was utilized for any deviation from a 30 day mission time, and only existing design basis hot-leg recirculation methods were credited. The following summarizes the evaluation of downstream components that was performed at PTN-3.

Debris Concentration and Size Distribution The PTN-3 debris concentration and size distribution for downstream effects wear was calculated based upon the methodology provided by WCAP-16406-P, except as otherwise noted.

The total debris load was determined for a bounding LBLOCA in accordance with NEI 04-07. A minimum sump water volume for recirculation was determined for a SBLOCA to maximize the debris concentration in containment. All debris was assumed to be in the sump pool and eroded (to the extent it would be after 30 days) at the start of recirculation. Only RMI and fiberglass insulation (Nukon) were categorized into fines and debris too large to pass the strainer (e.g., small, large, and intact); this categorization was based on industry experimental data. All other debris was assumed to be entirely fines, capable of passing the strainer unless its final eroded size is larger than 0.125 in. based on a detailed size distribution described below (see above regarding debris size assumed to pass through the strainer). Based on these inputs, the initial debris concentration at the start of recirculation was calculated.

The debris concentration was then depleted over the recirculation mission time in accordance with the methodology presented in WCAP-1 6406-P Section 5. For the purposes of debris depletion, only latent particulate debris, Microtherm, Cal-Sil, and unqualified coatings were size distributed. The Cal-Sil and latent debris size distributions were calculated from industry data, and Microtherm was assumed to have a similar distribution to Cal-Sil. The distributions were calculated based on empirical data and for the specific debris types at PTN-3, but the distribution was not based on plant-specific testing. For unqualified coatings, the size/mass distributions of the WCAP-1 6406-P were used. Qualified coatings were not taken to fail entirely to 10 micron spherical particulate, which is consistent with the WCAP-16406-P as amended by the SER Section 3.2.15 since a fibrous thin-bed was not substantiated. While SER Section 3.2.15 states that plant-specific analysis should be performed to size the coating debris, 50 microns was assumed as the coating debris size for qualified coatings based on the upper size limit documented in NEI 04-07 Appendix A.

The particulate debris distribution (in addition to reducing the amount of debris assumed to initially pass the strainer, as discussed above) was utilized to deplete the particulate over time due to settling in the reactor vessel. Consistent with the WCAP-16406-P guidance, the particulate debris size subject to vessel depletion was calculated for each debris type based on force balance methods using a maximum core flow rate (cold leg recirculation for a hot leg break) to minimize debris settling. All particulate debris was assumed to be spherical for determination of settling size. Debris smaller than the calculated size for a given type was taken to remain in solution throughout recirculation. Two cases were analyzed for particulate depletion: a high vessel flow rate that would occur if low-head safety injection were used during

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 38 of 89 long-term recirculation was used to calculate particulate depletion for input into the LHSI pump wear analysis (discussed below); a lower vessel flow rate that would occur if high-head safety injection were used was used to calculate particulate depletion HHSI pump wear analysis. The depletion coefficient for depletable particulate was calculated according to WCAP-1 6406-P Section 5.8 based on plant specific inputs for conditions to minimize depletion.

Two deviations were taken from the WCAP-16406-P approach with respect to fibrous debris depletion. First, all fiber was assumed to be depletable and no fibrous debris is too small as to remain in solution. Second, in lieu of the 95% fiber capture efficiency for the strainer suggested by WCAP-16406-P, or an empirically determined fiber capture efficiency as stated by the SER Section 3.2.17, the strainer capture efficiency was calculated based on an equation originally found in Draft Rev. 0 of the WCAP-16406-P. This resulted in a conservative strainer capture efficiency of only 45.29%. However, in all cases, the depletion coefficient used for the fibrous debris was the SER and WCAP-16406-P agreed conservative value of (X = 0.07/hr or half-life of 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br />).

For analysis of abrasive wear (pump moving parts), the debris was further categorized based on the size distribution of particulate debris as erosive versus abrasive debris. All fibrous debris was assumed to be large enough to be abrasive. For particulate debris, a modification to the WCAP-1 6406-P methodology was used to refine the distribution of abrasive versus erosive debris. While the WCAP-16406-P considers 50 microns to be the constant threshold for abrasive debris (which is equal to 2.5X the wear ring gap of the hypothetical pump considered therein), PTN-3 used 2.5X the actual wear ring gap at any given time to define the threshold for abrasive-sized particulate. In other words, as the wear ring gap opens, the abrasive debris is reduced. However, the amount of abrasive debris that was reduced was then taken to contribute to erosive wear.

The calculation of erosive wear considered the effect of small particulates. Credit was taken for reduced erosive wear in accordance with the Hutchings Summation methodology presented in WCAP-16406-P Appendix F. The Hutchings Summation was conservatively calculated based upon the particulate distribution discussed above.

The time-dependent debris concentration calculated according to the above methodology was then utilized for the calculation of wear on all ECCS and CSS recirculation components. The calculation of wear for each type of component, including the effect of the wear on component performance, is summarized below.

Pumps The ECCS and CSS pumps were analyzed for wear in general accordance with the methodology presented in Sections 7.2 and 8.1 of WCAP-16406-P. The depleting abrasive and erosive debris concentrations as discussed above were a primary input of the analysis.

For all pumps, the wear rings were assumed to have a starting gap equal to the midpoint of the wear ring acceptability range prescribed by the pump manufacturer. All wear rates were calculated specifically for each PTN-3 pump based on actual pump dimensions, materials, and operating speeds, and the debris concentration at a given time (the generic wear rates determined in the WCAP-16406-P were not applied). The wear analysis considered the

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 39 of 89 combined effect of abrasive wear due to larger debris and debris packing, and erosive wear due to smaller debris (as defined above). The wear rate at each hour was numerically integrated to determine the total material wear following the recirculation mission time.

Pump wear analysis considered the combined effect of abrasive wear due to larger debris, and erosive wear due to smaller debris (as defined above). In accordance with WCAP-16406-P Appendix Q and the SER Section 3.2.23, a penalty was not applied to the debris concentration wear rate because the total concentration of abrasive particulates and fibrous debris did not exceed 720 PPM. A conservative deviation from the WCAP-1 6406-P approach was made in that all debris large enough to be abrasive was considered to wear equally, as opposed to the WCAP-16406-P approach of taking coatings as softer. In accordance with the SER Section 3.2.23, the ratio of abrasive to fibrous debris is greater than 5 to 1, but this is inconsequential since the bounding concentration penalty is not applicable.

The single-stage CS and LHSI pumps were analyzed for symmetrical wearing of the inboard and outboard wear rings (no "suction multiplier" was applied). Packing-type wear was not applied to the single-stage pumps, in accordance with the WCAP-16406-P. The total material wear after the recirculation mission time was then used to determine the final wear rings gaps for the suction and discharge side. The change in gap was used to evaluate the impact on pump hydraulic performance per the approach of WCAP-1 6406-P Section 8.1. The discharge head following 30 days of wear was determined to be acceptable for the CS and LHSI pumps.

Per WCAP-1 6406-P Section 8.1.4, no vibration analysis was performed for single-stage pumps.

The mechanical seals were evaluated for debris interference concerns as discussed above.

The multistage HHSI pumps were also analyzed for concurrent abrasive and erosive wear.

Here, however, packing-type abrasive wear was found to be more limiting than free-flowing abrasive wear. Therefore, the HHSI pumps were analyzed according to the Archard wear model presented by WCAP-16406-P Appendix 0. For inputs into the Archard wear equation, the pressure drop across the wear rings was calculated for the actual PTN-3 pumps based on actual pump head at the expected recirculation flow rate, actual pump (subcomponent) dimensions were used, the eccentricity was assumed maximum, and the wear coefficient was taken as the bounding of the range provided by the WCAP-1 6406-P. The packing was assumed to occur immediately upon pump recirculation initiation, and to continue until a wear ring gap of 50 mils was attained, at which point the packing at each discharge-side wear ring was assumed to expel, in accordance with the WCAP-1 6406-P methodology. If the expulsion of the packing occurred prior to the end of the analyzed mission time, the wear of the discharge side wear ring was analyzed for continuing abrasive and erosive wear (free-flow) until the end of the mission time. The suction-side wear rings were taken to wear asymmetrically as a result of the packing-wear on the discharge side, and were analyzed using a suction multiplier of 0.205, per PWR Owners Group document OG-07-510.

The final wear ring gap of the suction and discharge sides after the recirculation mission time was then utilized to perform hydraulic and vibration analyses of the multistage pumps. Based on the pumps' starting discharge head (per IST history) and the acceptable range, the discharge head following 30 days of wear was determined to be acceptable for the HHSI pumps. The shaft centering load (Lomakin effect) method in WCAP-1 6406-P Appendix 0 was used to evaluate the HHSI pumps for vibration failure due to wear. In order to maximize vibration, the centering load was maximized by assuming a minimum friction coefficient,

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 40 of 89 maximum eccentricity, and also maximized in relation to Cd (diametric clearance) and f (friction coefficient). Again, the wear ring pressure drop was calculated based on actual pump head at the expected recirculation flow rate. The resulting shaft stiffness based on the centering load and wear ring gap was calculated using the suction and discharge side wear ring gaps following 30 days of wear. The stiffness was compared with the stiffness that would result from doubling the manufacturer's allowable wear ring gap (symmetric wear acceptability criterion from WCAP-16406-P). The shaft stiffness of the HHSI pumps under asymmetric wear was found to be greater than this acceptance criteria, and therefore the HHSI pumps were determined to be acceptable with respect to vibration. The mechanical seals were evaluated for debris interference concerns as discussed above.

Non-mechanistic failure of an ECCS or CSS pump seal is considered as a single-failure in the plant design basis and is acceptable. The WCAP-16406-P attempts to justify failure of the seals due to recirculation debris, which is a potential common-mode failure. The HHSI and LSHI pump seals at PTN-3 have been evaluated as not susceptible to failure by debris-laden water because they recirculate only seal cavity fluids, while the CS pump seal injection system using process water and a cyclone separator has been evaluated as acceptable for long-term recirculation. Therefore the only potential failure that must be considered is an assumed single failure,-which again is part of the existing design basis of the plant (bounded by a moderate energy line break in the pump room). The potential effect of debris causing an increased leakage flow through the disaster bushing following that single-failure has been evaluated and been determined to be acceptable.

The WCAP-16406-P criteria were based on performance of each individual component.

However, the SER further identifies the need to check the entire ECCS and CSS systems in an integrated approach to ensure that the combination of pump and system component wear would not threaten adequate core cooling, considering increased system flow and decreased pump performance due to wear. An overall system performance assessment determined that these systems remain capable of fulfilling their required safety related functions in the presence of debris-laden fluid following a LBLOCA at the PTN-3 Nuclear Power Plant.

Heat Exchanqers In accordance with WCAP-16406-P Section 8.3, the recirculation heat exchangers (both the primary system heat exchangers, and the pump seal heat exchangers) were analyzed for erosive wear. The standard erosive wear formulas in the WCAP-16406-P, adjusted for the actual material hardness and adjusted via the Hutchings Summation described above, were used with the PTN-3 heat exchanger dimensions and maximum recirculation flow rates to predict the maximum erosive wear over 30 days of recirculation. All heat exchangers were found to have sufficient wall thickness margin for a maximum possible differential pressure across the heat exchanger tubes.

Valves The WCAP-1 6406-P guidance is that manual throttle valves should be analyzed for the effects of erosive wear. It is assumed that a manually throttled valve as defined in WCAP-16406-P is one that requires an operator to locally throttle the valve (at the valve location) as opposed to a remote manual valve that can be adjusted from the control room.

It is further assumed that a

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 41 of 89 remote manual valve can be adjusted from the control room to compensate for an increase in flow area due to erosive wear. Therefore, erosion wear analyses were not performed for remote manual valves. Since there are no locally throttled ECCS or CSS valves at PTN-3, no wear analysis was required to assess downstream effects on valves in the recirculation paths.

Orifices, Flow Elements, Spray Nozzles All orifices, flow elements, and the containment spray nozzles in the PTN-3 recirculation flowpaths were analyzed for the effects of erosive wear upon performance. The standard erosive wear formulas in the WCAP-1 6406-P, adjusted for the actual material hardness and adjusted via the Hutchings Summation described above, were used with the PTN-3 component dimensions and maximum recirculation flow rates to predict the maximum erosive wear over 30 days of recirculation. The total material wear was used with the WCAP-16406-P formulas to predict the maximum change in flow rate due to the erosive wear of an orifice, flow element or spray nozzle. A conservative deviation was made from the WCAP-1 6406-P guidance in that a 3% limit for change in flow was applied for all orifices, flow elements, and spray nozzles.

Furthermore, all orifices were assumed to be sharp-edged, which creates a higher change in flow rate for a given amount of wear. Based on the analysis, all PTN-3 orifices, flow elements, and the containment spray nozzles were found to be acceptable. Only the CSS spray nozzles were found to exceed the 3% for negligible change in flow, but a conservative evaluation of the impact on system performance (including pump NPSH available) determined that the change in flow was acceptable.

alp-in The SER to WCAP-16406-P requires that licensees perform a piping wear evaluation. The SER Section 3.2.6 does not detail the scope of the assessment, but since it refers to the need for a vibration assessment if areas of high piping wear are identified, it is taken to mean that piping should be checked for wall-thinning (structural) purposes like the heat exchanger tubes.

With regard to pipe wall erosion, WCAP-16406-P states "There is no expected impact on ECCS and CSS piping based on downstream sump debris... since the pipe wall thickness is sufficiently larger than expected wear." To validate this assumption, the material wear of the bounding orifice in the ECCS and CSS was compared to the pipe wall thicknesses used in the systems.

This conservative material wear exceeds that applicable to piping because the flow velocities in piping are much less compared to the bounding orifice velocity (the wear rate is proportional to the flow velocity squared), while the material of construction is the same. The material wear was found to be insignificant compared to the pipe wall thick-nesses used in the ECCS and CSS. Therefore, all recirculation pipes were determined to have sufficient margin, and the erosion was considered so slight as to not require vibration analysis.

Conclusion (Wear)

No other components required erosive wear analysis. As summarized above, analysis of all lines and components in the recirculation flowpaths at PTN-3 determined that the components are expected to wear acceptably based on the WCAP-16406-P criteria for 30 days of recirculation.

The WCAP criteria were based on the performance of each individual component. The SER

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 42 of 89 further identifies the need to check the ECCS and CSS systems in an integrated approach to ensure that the combination of pump and system component wear would not threaten adequate core cooling, considering increased System flow and decreased pump efficiency due to wear.

Based on an overall system performance assessment, the ECCS and CSS remain capable of fulfilling their required safety related functions in the presence of debris-laden fluid following a LBLOCA at the PTN-3 Nuclear Power Plant.

Summary of Design or Operational Changes Additionally, NRC Content Guide Topic 3.m requests that licensees "Provide a summary of design or operational changes made as a result of downstream evaluations." Three plant.

design changes made in response to GSI-191 contribute to the resolution of downstream effects:

As previously discussed, in response to downstream blockage concerns the new strainer system was designed with nominal strainer opening holes of 3/32 in. diameter (0.09375 in.), reduced from the previous 1/4 in. nominal square opening (diagonal dimension of 0.354 in.). The new strainer system is described in the response to NRC Topic 3.j, Screen Modification Package. The actual maximum spherical size particulate debris that can pass through the new strainer system and into the ECCS and CSS recirculation flowpaths is documented as 0.1031 in.

In response to the WCAP-16406-P concern over blockage of pump seal cyclone separators by fibrous debris, the Nukon insulation on the pressurizer surge line was removed to reduce fibrous insulation in the recirculation fluid.

" The insulation on the Pressurizer Relief Tank was permanently removed and the tank coated with qualified coatings. This reduced the quantity of Cal-sil insulation that can be generated during a LOCA and thus resulted in decreased wearing of downstream components.

The only operational change made related to downstream effects is that inspection requirements were updated for the new strainer system. Inspection of the strainer system requires verification of maximum strainer equipment gaps to meet new specifications to maintain debris bypass size limits, and inspection now includes new strainer system piping in addition to the strainer filtration surface. This procedure is discussed further in NRC Topic 3.i, Debris Source Term.

No other design or operational changes were required in response to ECCS and CSS downstream effects evaluations.

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 43 of 89 Topic 3.n: Downstream Effects - Fuel and Vessel FPL response FPL participated in the PWR Owners Group (PWROG) program to evaluate downstream effects related to in-vessel long-term cooling. The results of the PWROG program are documented in WCAP-16793-NP (WCAP-16793-NP, "Evaluation of Long-Term Cooling Considering Particulate, Fibrous and Chemical Debris in Recirculating Fluid," Rev. 0, May, 2007), which was provided to the NRC staff for review in June 2007. The program was performed such that the results apply to the entire fleet of PWRs, regardless of the design (e.g.,

Westinghouse, CE, or B&W).

The PWROG program demonstrated that the effects of fibrous debris, particulate debris and chemical precipitation would not prevent adequate long-term core cooling flow from being established. In the cases that were evaluated, the fuel clad temperature remained below 800 OF in the recirculation mode. This is well below the acceptance criterion of 2200 OF in 10 CFR 50.46, "Acceptance Criteria For Emergency Core Cooling Systems For Light-Water Nuclear Power Reactors." The specific conclusions reached by the PWROG are noted below.

" Adequate flow to remove decay heat will continue to reach the core even with debris from the sump reaching the RCS and core. Test data has demonstrated that any debris that bypasses the screen is not likely to build up an impenetrable blockage at the core inlet.

While any debris that collects at the core inlet will provide some resistance to flow, in the extreme case that a large blockage does occur, numerical analyses have demonstrated that core decay heat removal will continue. Per WCAP 16793-NP, Revision 0, no plant specific evaluation is recommended. This conclusion thus applies to Turkey Point Unit 3.

Decay heat will continue to be removed even with debris collection at the fuel assembly spacer grids. Test data has demonstrated that any debris that bypasses the screen is small and consequently is not likely to collect at the grid locations. Further, any blockage that may form will be limited in length and not be impenetrable to flow. In the extreme case that a large blockage does occur, numerical and first principle analyses have demonstrated that core decay heat removal will continue. Per WCAP 16793-NP, Revision 0, no plant specific evaluation is recommended. This conclusion thus applies to Turkey Point Unit 3.

Fibrous debris, should it enter the core region, will not tightly adhere to the surface of fuel cladding. Thus, fibrous debris will not form a "blanket" on clad surfaces to restrict heat transfer and cause an increase in clad temperature. Therefore, adherence of fibrous debris to the cladding is not plausible and will not adversely affect core cooling. Per WCAP 16793-NP, Revision 0, no plant specific evaluation is recommended. This conclusion thus applies to Turkey Point Unit 3.

" Using an extension of the chemical effects method developed in WCAP-16530-NP to predict chemical deposition of fuel cladding, two sample calculations using large debris loadings of fiberglass and calcium silicate, respectively, were performed. The cases demonstrated that decay heat would be removed and acceptable fuel clad temperatures would be maintained.

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 44 of 89 WCAP-16530-NP Revision 0 evaluated the potential for chemical precipitation to form on the cladding surface as summarized in the preceding bullet, which is demonstrated in WCAP-16793, Revision 0, to produce acceptable fuel clad temperature results for two sample cases.

As recommended in the WCAP-16793-NP, Revision 0, FPL has performed a plant.-specific calculation using plant-specific parameters and the recommended WCAP methodology to confirm that chemical plate-out on the fuel does not result in the prediction of fuel cladding temperatures approaching the 800 OF value. This calculation concluded that the maximum fuel cladding temperature is 366.04 OF.

The Turkey Point Unit 3 responses to the NRC staff's Limits and Conditions related to the staff review of WCAP 16793-NP are provided in Enclosure 2.

The Turkey Point Unit 3 responses to the NRC staff's Limits and Conditions related to the staff review of WCAP 16530-NP are provided in Enclosure 3.

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 45 of 89 Topic 3.o: Chemical Effects FPL Response As discussed in our December 7, 2007, extension request, although the identified corrective actions have been completed, the impact of chemical effects on full implementation of GSI-191 corrective actions was not able to be fully assessed until this June 30, 2008 submittal.

Therefore, responses to the staff's RAI items related to chemical effects in the NRC RAI dated February 8, 2006 (TAC Nos. MC4725 and MC4726) are now provided herein. The available NPSH margin was updated to incorporate the results of the chemical effects tests and analyses and is discussed in Topic 3g, Net Positive Suction Head (NPSH).

The NRC Issues related to Topic 3.0 in accordance with Enclosure 3, chemical effects, to the letter from the NRC to NEI dated September 27, 2007 are presented below. The responses to those issues are then presented, as applicable to PTN-3. Additionally, answers to the chemical effects RAIs are presented below.

1. Provide a summary of evaluation results that show that chemical precipitates formed in the post-LOCA containment environment, either by themselves or combined with debris, do not deposit at the sump screen to the extent that an unacceptable head loss results, or deposit downstream of the sump screen to the extent that long-term core cooling is unacceptably impeded.
2. Content guidance for chemical effects is provided in Enclosure 3 to a letter from the NRC to NEI dated September 27, 2007 (ADAMS Accession No. ML0726007425).

2.1 Sufficient 'Clean' Strainer Area: Those licensees performing a simplified chemical effects analysis should justify the use of this simplified approach by providing the amount of debris determined to reach the strainer, the amount of bare strainer area and how it was determined, and any additional information that is needed to show why a more detailed chemical effects analysis is not needed.

2.2 Debris Bed Formation: Licensees should discuss why the debris from the break location selected for plant-specific head loss testing with chemical precipitate yields the maximum head loss. For example, plant X has break location I that would produce maximum head loss without consideration of chemical effects.

However, break location 2, with chemical effects considered, produces greater head loss than break location 1. Therefore, the debris for head loss testing with chemical effects was based on break location 2.

2.3 Plant Specific Materials and Buffers: Licensees should provide their assumptions (and basis for the assumptions) used to determine chemical effects loading: pH range, temperature profile, duration of containment spray, and materials expected to contribute to chemical effects.

2.4 Approach to Determine Chemical Source Term (Decision Point): Licensees should identify the vendor who performed plant-specific chemical effects testing.

2.5 Separate Effects Decision (Decision Point): State which method of addressing plant-specific chemical effects is used.

2.6 AECL Model: Since the NRC USNRC is not currently aware of the testing approach, the NRC USNRC expects licensees using it to provide a detailed discussion of the chemical effects evaluation process along with head loss test

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 46 of 89 results. Licensees should provide the chemical identities and amounts of predicted plant-specific precipitates.

2.7 WCAP Base Model: Input of plant parameters into the WCAP-16530 spreadsheet should be done in a manner that results in a conservative amount of precipitate formation. In other words, plant parameter inputs selection will not be biased to lower the predicted amount of precipitate beyond what is justified.

Analysis, using timed additions of precipitates based on WCAP-16530 spreadsheet predictions should account for potential non-conservative initial aluminum release rates. Licensees should list the type (e.g., AlOOH) and amount of predicted plant-specific precipitates.

2.8 WCAP Refinements: State whether refinements to WCAP-16530-NP were utilized in the chemical effects analysis. Conservative assumptions in the WCAP-16530 base model were intended to balance uncertainties in the GSI-191 chemical effects knowledge. Therefore, overall chemical effects assessment remains conservative when implementing these model refinements.

2.9 Solubility of Phosphates, Silicates and Al Alloys: Licensees should clearly identify any refinements (plant-specific inputs) to the base WCAP-16530 model and justify why the plant-specific refinement is valid.

" For crediting inhibition of aluminum that is not submerged, licensees should provide the substantiation for the following: (1) the threshold concentration of silica or phosphate needed to passivate aluminum, (2) the time needed to reach a phosphate or silicate level in the pool that would result in aluminum passivation, and (3) the amount of containment spray time (following the achieved threshold of chemicals) before aluminum that is sprayed is assumed to be passivated.

For any attempts to credit solubility (including performing integrated testing),

licensees should provide the technical basis that supports extrapolating solubility test data to plant-specific conditions. In addition, licensees should indicate why the overall chemical effects evaluation remains conservative when crediting solubility given that small amount of chemical precipitate can produce significant increases in head loss.

Licensees should list the type (e.g., AlOOH) and amount of predicted plant specific precipitates.

2.10 Precipitate Generation (Decision Point): State whether precipitates are formed by chemical injection into a flowing test loop or whether the precipitates are formed in a separate mixing tank.

2.11 Chemical Injection into the Loop: Licensees should provide the one-hour settled volume (e.g., 80 ml of 100 ml solution remained cloudy) for precipitate prepared with the same sequence as with the plant-specific, in-situ chemical injection.

" For plant-specific testing, the licensee should provide the amount of injected chemicals (e.g., aluminum), the percentage that precipitates, and the percentage that remains dissolved during testing.

Licensees should indicate the amount of precipitate that was added to the test for the head loss of record (i.e., 100 percent 140 percent).

2.12 Pre-Mix in Tank: Licensees should discuss any exceptions taken to the procedure recommended for surrogate precipitate formation in WCAP-16530.

2.13 Technical Approach to Debris Transport (Decision Point): State whether near-field settlement is credited or not.

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 47 of 89 2.14 Integrated Head Loss Test with Near-Field Settlement Credit: Licensees should provide the one-hour or two-hour precipitate settlement values measured within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of head loss testing.

2.14a Integrated Head Loss Test with Near-Field Settlement Credit: Licensees should provide a best estimate of the amount of surrogate chemical debris that settles away from the strainer during the test.

2.15 Head Loss Testing Without Near Field Settlement Credit: Licensees should provide an estimate of the amount of debris and precipitate that remains on the tank/flume floor at the conclusion of the test and justify why the settlement is acceptable.

2.15a Head Loss Testing Without Near Field Settlement Credit: Licensees should provide the one-hour or two-hour precipitate settlement values measured and the timing of the measurement relative to the start of head loss testing (e.g.,

within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />).

2.16 Test Termination Criteria: Provide the test termination criteria.

2.17 Data Analysis: Licensees should provide a copy of the pressure drop curve(s) as a function of time for the testing of record. Licensees should explain any extrapolation methods used for data analysis.

2.18 Integral Generation (Alion): Licensees should discuss why the test parameters (e.g., temperature, pH) provide for a conservative chemical effects test.

2.19 Tank Scaling / Bed Formation: Explain how scaling factors for the test facilities are representative or conservative relative to plant-specific values. Explain how bed formation is representative of that expected for the size of materials and debris that is formed in the plant specific evaluation.

2.20 Tank Transport: Explain how the transport of chemicals and debris in the testing facility is representative or conservative with regard to the expected flow and transport in the plant-specific conditions.

2.21 30-Day Integrated Head Loss Test: Licensees should provide the plant-specific test conditions and the basis for why these test conditions and test results provide for a conservative chemical effects evaluation. Licensees should provide a copy of the pressure drop curve(s) as a function of time for the testing of record.

2.22 Data Analysis Bump Up Factor: Licensees should provide the details and the technical basis that show why the bump-up factor from the particular debris bed in the test is appropriate for application to other debris beds.

Issue 3.o.1:

Chemical precipitates that form in the post-LOCA containment environment combined with debris do not result in an unacceptable head loss. The effects of the sump chemical environment were evaluated in an integrated chemical effects head loss test by Alion at the VUEZ test facility. The results of the chemical effects testing has been incorporated into the NPSH calculations as discussed in section 3.g above.

Issue 3.o.2.1 Although Turkey Point 3 installed a very large strainer (>5,500 ft2) and has a low fiber load, a "simplified" chemical effects evaluation was not performed. Debris head loss testing was

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 48 of 89 performed utilizing stirrers to ensure the debris did not settle.

Issue 3.o.2.2 Turkey Point 3 has performed prototype sector testing of the GE Modular Stacked Disc Strainer at the CDI test facility without chemical surrogates to develop the non-chemical debris head losses. The Modular Strainer also makes use of the GE Debris Plate to mitigate thin-bed effects. Based on the plant specific head loss testing, a limiting debris load case was selected to be evaluated for chemical effects.

Issue 3.o.2.3 The following assumptions were applied to chemical effects testing for head loss.

The pH profile is based on an initial reactor coolant system pH value of 5.0 (2,350 ppm Boron) immediately after the LOCA. The pH of the sump is raised to a maximum value of 7.2 with sodium Tetraborate (NaTB).

The containment and sump temperature profile ranges from 120OF to 270 OF. The maximum test temperature and range is 120*F to 1901F. Material corrosion greater than 190OF was included in the test by adding more surface area for a prescribed period of time.

Containment sprays are assumed to be in operation for the full 30-day mission time.

The materials considered to contribute to chemical effects are: concrete, zinc, carbon steel, aluminum, and fiberglass.

Issue 3.0.2.4 Alion Science and Technology performed plant-specific chemical effects testing. The testing protocol is the VUEZ 30 day integrated chemical effects testing.

Issue 3.o.2.5 Turkey Point 3 does not use the WCAP or AECL based models for testing. Additionally, near field settling was not credited and the test was run for 30 days.

Therefore, responses to items 3.o.2.6 throuqh 3.o.2.17 are not applicable.

Issue 3.o.2.18 Alion's VUEZ CE Test Program is designed to replicate the potential corrosive interactions of the spray and pool fluid chemistry with those materials and debris sources in containment and resident on the sump screen. These potential interactions may cause additional precipitates and/or impacts on debris head loss over the 30-day mission time. To provide representative testing, certain scaled parameters are selected to ensure that the reactions take place in the correct quantity and environment and that the resulting debris head losses satisfactorily reflect any chemical effects. Critical plant parameters include sump screen area, recirculation fluid volume, recirculation flow rate, containment debris, and recirculation pool chemistry

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 49 of 89 (temperature and pH).

The test tank and setup represents these containment parameters to replicate the corrosion potential of the structural materials inside containment. The testing preserves the material surface area to pool volume similar to the integrated chemical effects testing (ICET); past experience with these types of corrosion tests have shown that the release rate is based on surface area of the material and not necessarily the mass.

UIUO U.Z. 10-1.

VUE=L.

I e5L I drIKS krOW 01 SIX)

Submerged materials are insulation, debris or other material that is below the sump water level and not transported to the sump. This material does not directly contribute to sump screen head loss but can affect pool pH and chemical properties. Unsubmerged materials are materials within containment that undergo coolant spray but are above the pool volume. These materials do not contribute to head loss or pool chemistry directly but can affect the pool pH and chemistry due to coolant spray corrosion and run off that enters the containment pool.

Materials that reach the sump screen are insulation and debris that are created by the line break and transport to the sump screen via the containment pool recirculation. These materials contribute to the sump screen head loss via bed thickness and porosity.

The containment materials included are divided into the three categories that correspond to exactly where the materials will lie within the test tank: submerged, unsubmerged, and on the sump screen. Each category is scaled according to either pool volume ratio or screen area ratio of the plant versus the test apparatus based on the transport characteristics or residence of the debris within the containment.

Chemical loads that are present in the containment pool were conserved by using the same concentration (ppm by weight value) in testing'as is present in containment. The temperature and pH curves that would be present in the containment pool were represented during testing.

The chemical effects testing parameters are derived from the containment parameters and are conservative for the following reasons:

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 50 of 89

1. The quantities of materials that contribute to chemical effects are provided by the plant personnel based on the design documents, walkdowns or conservative estimates. The materials included in the testing are concrete, aluminum, zinc, carbon steel, dirt/dust and LOCA generated debris. Metallic coatings are represented by sheet materials.
2. The scale between the containment material to pool Volume and test material to pool volume is preserved to the extent possible.
3. Although the testing was limited to a maximum temperature of 1900 F, the release of materials expected in containment at temperatures greater than 1900 F was accounted for through an increase in materials (additional coupons).
4. The test fluid pH profile throughout the test is based on design basis containment sump pH profile.

The following sections discuss the selection of the test parameters.

Temperature Adiustment/Temporary Material The test program was designed to replicate the potential corrosive interactions of the spray and pool fluid chemistry with those materials and debris sources in containment and resident on the sump screen. To provide a representative test, it was necessary to ensure that the quantity of corrosion products released in the plant containment environment were reproduced in the test environment such that the resulting debris head losses satisfactorily reflected the plant's chemical effects. Since the test has limit of 1900 F, an adjustment is required to ensure the quantity of material released at 1900 F in the test equaled the quantity of materials released at temperatures above 1900 F.

The elemental release rates were determined based on the method and equations in WCAP-16530-NP and are based on the Arrhenius principle. The release rates from the plant and test profiles were correlated to determine material adjustments or dwell adjustments for the chemical effects testing to conservatively generate the chemical effects products that would not otherwise be generated since the post LOCA containment and sump temperatures are higher than the maximum operating temperature that can be attained in the test apparatus.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 51 of 89 PTN-3 Temperature Profile 280.0 260.0-250.0 240.0 L.230.0......

a220.0-----

~210.0-----

-200.0 2190.0. __

1H S180.0

&*L170.0 -

1 1! 1 50.0 140.0 130.0 120.0 1.E021.E01I.E001.E+01 1.+21.E+03 1.E+04 1.E+05 1.E+06 1.E+07 Time, seconds post LOCA

-.- Sump -n.m-Containment -VUEZ Test Figure 3o.2.18-2: PTN-3 Temperature Profile The test method focuses on the pre-recirculation time period and on the post recirculation time period up to the time the sump temperature drops to 190 OF. In these time periods the plant's temperature profile is higher than the test apparatus temperature profile and therefore the higher the plant's temperature, the higher chemical release rates and consequently the higher the total releases. To match the plant's total releases during this period above 1900 F, the quantity of material in the test apparatus was increased until such time the temperature fell below 1900 F. The method used to determine the additional quantity of materials was based on the method and equations in WCAP-16530-NP.

The WCAP-1 6530-NP method first evaluates the elemental release rates of Al, Si and Ca as function of time, for the time period that the plant sump temperature is higher than 190 OF, for the respective plant and test temperature and pH profiles. The elemental release rates of Al, Si and Ca as a function of time for these time periods are then calculated and the ratio of the elemental releases (sumpNUEZ test) as a function of time determined. These elemental ratios of the release rates are integrated as a function of time. The integrated ratios of the release rates in effect show the relationship between the plant and test time that would result in the generation of equal releases of Al, Si and Ca within a time interval of interest. The results of this evaluation are used to increase the test material to generate the same integrated releases within any time period that the plant temperature exceeds the test temperature.

Acids and Bases (pH)

The testing begins with the addition of the requisite amount of boron (2350 ppm) through the addition of boric acid. The pH during this phase is approximately 5.0. Reviewing the industry testing, ALION benchtop tests and VUEZ results have revealed that the primary release during this phase is calcium and it is not overly sensitive to small changes in pH units. It has been noted that debris in demineralized water will raise the pH of the water due to the alkalinity of the

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 52 of 89 fiberglass and calcium silicate. When adding the requisite amount of boron to the system, the pH was approximately 5.7. At the lower pHs, the relevant corrosion is to the concrete and the release of calcium. A review of the results of the 30 day testing yielded calcium levels greater than that of ICET and increasing over time with no precipitation from calcium. Therefore, not achieving the lower bound pH of 5.0 is of little significance to the results.

Conservative Effect on TestinQ PTN-3 is only minimally represented by ICET Test #5, as ICET #5 contained significant amounts of NUKON fiberglass insulation. ICET Test #5 was fiberglass/cal-sil in a sodium tetraborate (NaTB) environment with a pH of approximately 8.2 to 8.4. The maximum pH of PTN-3 is only 7.2 and should produce minimal corrosion products. The following table provides a comparison of the material surface area to fluid volume ratios.

Table 3o.2.18-1:

PTN-3 Containment Material Surface Area to Pool Volume Ratios WCAP-Containment Materials PTN-3 Specific ICET Test #5 16530-NP Zinc in Galvanized Steel 2.3 ft2/ft3 8.0 ft2/ft3 19.5 ft2/ft 3 Zinc Coatings 4.2 ft2/ft 3 4.6 ft2/ft 3 28.0 ft2/ft 3 Aluminum 1.6 ft2/ft 3 3.5 ft2/ft3 5.42 ft2/ft3 Copper 0.0 ft2/ft 3 6.0 ft 2/ft 3 11.11 ft2/ft 3 Carbon Steel 0.003 ft2/ft 3 0.15 ft2/ft3 10.78 ft2/ft 3 Concrete Surface 0.04 ft2/ft 3 0.045 ft2/ft3 4.79 ft2/ft 3 Fiber 1.5E-4 ft3/ft 3 1 3 0.23 ft3/ft 3 Calcium Silicate 0.0017 ft3/ft 3 0.18 ft3/ft 3 Microtherm 7.2E-5 ft3/ft 3 0.0 ft 3/ft3 5.5E-4 ft3/ft 3 WCAP-16530-NP and WCAP-1 6785-NP computer analyses postulated that the precipitate material is Sodium Aluminum Silicate (NaAlSi 30 8) and Aluminum Oxyhydroxide (AIOOH) because of the excess dissolved aluminum. As noted, however, the WCAP model may over predict the Al release with silica in solution - PTN-3 does contain a considerable amount of silica and a relatively neutral pH (7.2) with NaTB.

The test was designed to maximize the pH and temperature of the test to promote corrosion while ensuring the minimum containment sump temperature was realized to ensure any potential precipitation could be evaluated for impact on head loss.

Issue 3.o.2.19

1.

Scaling Factors The testing was conducted with scaled, representative material surface areas, sump volumes

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 53 of 89 and chemical constituents to provide conditions closely simulating the post-LOCA sump environment. In order to promote the reactions that would be expected in this environment, the test tank contained the proportions of non-metallic, metallic, and construction materials similar to those present in the PTN-3 containment environments.

Structural and debris materials were obtained from plant surveys or documents and scaled for input into the 30 day chemical test. In several cases, debris materials were determined to be inert and suitable surrogates were selected for development of the debris bed. The materials considered in the test were:

NUKON Aluminum Carbon Steel

" Zinc Concrete Calcium Silicate Microtherm The scale testing was configured to achieve the following conditions:

1. The test apparatus screen average fluid approach velocity should be greater than or equal to the containment sump screen representative average approach velocity within the limits of the test equipment.
2. The temperature and pH conditions of the tests should be as representative as possible of the actual containment conditions.
3. The ratio of the test material surface area to tank volume should be equal to that of the containment materials surface area to containment pool volume.
4. The fibrous debris bed thickness on the screen of the test apparatus should be equal to the containment sump screen equivalent debris bed thickness.

The control of the parameters defined above ensured that the corrosion/leaching conditions and debris head loss characteristics that occur during the test were representative of the containment conditions during the postulated LOCA.

2.

Bed Formation The VUEZ 30-day debris head loss testing represents a combination of ICET and vertical loop debris head loss testing. The screen installed in the test is a horizontally oriented flat plate on which the plant specific debris bed was developed and head loss measured. The screen is slightly spherical on the bottom to inhibit the formation of voids that may build up underneath the debris bed. The sump solution is circulated in the areas outside the suction plenum and drawn down through the debris bed and recirculated.

The debris bed developed in the VUEZ test loop provided a representative, average debris bed (bed thickness and composition) on which the impact of chemical effects was measured over the 30-day mission time.

The debris bed composition and thickness selected for the VUEZ chemical effects testing is

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 54 of 89 based on the range of plant specific debris loads and size characteristics determined in the plant-specific debris generation, transport, head loss analysis and prototype testing. The VUEZ size distribution selected is primarily represented by Classes 1 through 5 in Table 3-2 and Figure 3-3 (NUREG/CR-6808). This ensures that the characteristic size of the debris is small compared to the characteristic size of the VUEZ screen. Further, this leads on average to a higher debris density, which is expected to maximize the impact of any chemical precipitates that might form.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 55 of 89 Table 3-2 Size Classification Scheme for Fibrous Debris" No.

_______Oescroticri 1

Very -mall pieces of fiberglass material; 'microscopice fines that appear to be cylinders of varying UD.

2 Single, flexible strands of fiberglass; essentially acts as a suspending strand.

3 Multiple attached or inte:,oven strands that exhibit considerable flexibility and that, because of random orientations induced by turbulent dra,, can exhibit low settling velocities.

4 V

Fiber clusters that have more rigidity than Class 3 debris and that react to drag forces as a semi-rigid body.

5 Clumps of fibrous debris that ha.ve been noted to sink vM en saturated with water. Generated dY Ifferent merthods by various researchers but easily created by manual shredding of fiber matting.

6 Larger clumps of fibers li ng between Classes 5 and 7.

7 Fragments of fiber that retain some aspects of the original rectangular construction of the fiber matting. Typically precut pleces of a large blanket to simulate moderate.size segments of original blanket.

Figure 3-3. Fiberglass Insulation Debris of Two Example Size Classes The fibrous materials are boiled to remove the oils or gasses trapped within the fibers. This process helps to ensure that the materials do not agglomerate, float and simulate aging (lose resiliency). The material is then shredded consistent with standard head loss testing practices (leaf shredder, cuisenart, etc.) to resemble the size distribution presented in Table 3-2 and

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 56 of 89 Figure 3-3. The particulate surrogates are procured with an average size distribution near 10 micron.

The fiber and particulate mixture is thoroughly mixed in a beaker containing the test solution (Figure 3o.2.19-1). The mixture is slowly added through a funnel to ensure an even distribution across the test screen area while the pump is circulating (Figure 30.2.19-2). The bed is constructed to be uniform (minimal clumps, unevenness, etc.) to the extent possible by the technicians.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 57 of 89 Tank Screen and Metal Coupons PTN-3 Debris Bed Figure 3o.2.19-2: VUEZ Tanks Screen and PTN-3 Debris Beds The debris beds formed on the VUEZ screen are similar in that all the debris is accumulated on

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 58 of 89 the screen similar to the prototype testing provided in Figure 3o.2.19-3. The bed is similar in that debris is homogenously mixed into the tank and accumulates on the screen surface dependent upon localized flow velocities. The VUEZ debris bed is homogenously mixed and manually formed to be as uniform as possible to represent the overall debris bed on the sector.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 59 of 89 Figure 3o.2.19-3: Debris Bed on Test Article (Sector Test)

Issue 3.o.2.20 The circulation of fluid is essential to the development of a homogenous chemical solution by which corrosion and subsequent precipitation can occur. The testing is not a transport test and

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 60 of 89 therefore comparing plant floor velocities to test tank velocities is not a requirement. The test tank has sufficient turbulence to ensure the solution is passed by all metallic, concrete and fibrous surfaces and carries those dissolved species and any subsequent hydrated precipitates through the debris bed.

The circulation in the test tank is approximately 1.0 liter/min. The loop is approximately 59 liter and therefore the fluid is turned over approximately once every 59 minutes. The PTN-3 minimum sump volume is between 32,136 ft3 and 51,900 ft3, respectively. This would produce a pool turnover between 64 and 103 minutes at the design flow rate of 375.0 gpm which is slightly lower than that of test tank.

Issue 3.o.2.21 As stated in Section 3o.2.18, the temperature and pH of the test was selected to provide reasonable and conservative conditions to promote corrosion and precipitation within the plant specific condition evaluated. PTN-3 has many sources of silicate (concrete, calcium-silicate and fiberglass) and these silicates will inhibit the corrosion of aluminum. However, the pH of the fluid is only 7.2 and the corrosion of aluminum under these conditions is minimal.

Removing the silicate sources from the test would remove the debris sources on the screen and therefore any head loss from the testing.

From the VUEZ 30-day integrated head loss test wet chemistry results, the silica concentration is only about 13 ppm with an aluminum concentration of about 8 ppm. Although both levels are relatively low, it is relevant that the levels are decreasing and suggest potential precipitation/filtration.

Si ( 5)

(0.)

1.

,i,,

O 0127 071 11 07122-7113 071127 071211 071226 Date Date VUEZ 30 Day Silica Concentration VUEZ 30 Day Aluminum Concentration Figure 3o.2.21-1: VUEZ ICP Analysis of Fluid The following figure is the pressure loss curve as a function of time for the VUEZ 30 day test.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 61 of 89 TSVUEZ EQ#4 I Time history - TP31Case 5 i 14-13 -

12 -

11" 10 -

9-8 -

7 5-4-

3-2_"

0:

5-4 0

2 -

0-071119 1700 100 90 80 70 60 602 50.2 -

40 EC 30 20 10 5

4 3-2C 0

  • i
  • 0 0711241700 0711291700 0712041700 0712091700 0712141700 0712191700 Date/Time Figure 3o.2.21-2: VUEZ 30 Day Pressure Drop Time History Issue 3.o.2.22 Figure 3o.2.21-2 is the PTN-3 actual debris head loss time history over a varying temperature profile. The majority of the increase in debris head loss occurs at the addition of the NaTB buffer. Given the relatively thin calcium silicate bed, the bed itself was prone to boreholes after the 1 5th day most likely due to bed dissolution/deterioration over time and the GE wire mesh overlay.

The following Figure 3o.2.22-1 illustrates the progression of the development of the chemical bump-up factor. The chemical bump-up factor (CBU) is defined as the ratio of the head loss (dP) over temperature/time versus the demineralized water or non-chemical effects head loss.

From the VUEZ testing, the non-chemical effects head loss is the reference head loss at that point prior to the acid addition. Figure 3o.2.22-1 corrects the data presented in Figure 3o.2.21-2 for the flow reduction and bore holes. This correction is manual and documented in the test reports.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 62 of 89 (0

M0 M

90 85 80 75 0 0

653 55 50 0

100 200 300 400 500 600 700 Time (hr)

Figure 3o.2.22-1: PTN-3 Debris Bed Head Loss Time History (Corrected)

Figure 3o.2.22-2 presents the same data in Figure 3o.2.22-1 except adds the chemical bump up (CBU) factor which is the ratio of the head loss over the reference or non-chemical head loss. This reference value is 0.22 kPa and is obtained from the VUEZ raw data at time zero.

The next step in the process is to remove the impact of viscosity from the head loss term as we are investigating the impact of chemical effects only. Figure 3o.2.22-3 is a plot of the dynamic viscosity over a temperature range normalized to a selected temperature - where the ratio is 1.0.

Several figures containing ICP data have been added to this example to collaborate the chemical data with the head loss data. We are not directly correlating the chemistry with the head loss but providing supporting basis for what can be occurring in the solution and the debris bed.

Based on the solution ICP data presented, Figures 3o.2.22-4, 3o.2.22-5 and 3o.2.22-6 correlate the potential chemical precipitate to the increase in debris head loss. The K value represents the potential formation of NAS, and the Ksp value represents the solubility of NAS under these conditions. In this case, the ICP data would confirm the potential for sodium aluminum silicate (NAS) formation. As shown, the concentration of NAS exceeds the solubility limit immediately in the test.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 63 of 89 7.0 6.0 0 5.0 3.0 I-,

42.0 cc 1.0 0,0

-I 0

0 100 200 300 400 500 600 Time (hr) 700 Figure 3o.2.22-2: Debris Head Loss/Chemical Bump-up Factor Time History 4.0 3.5 o

3.0 2.5 0

2.0 0

1.5 a.

1.0 0.5 0.0 90 80 70 60 50 T(C) 40 30 20 Figure 3o.2.22-3: Viscosity of Water vs. Temperature Ratio (normalized)

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 64 of 89 40 35 30 8

7 7

--7

_+...

....!....+ __8 o _

e+

0 U-VUEZ.ICP C-5 4M E.

0.-

0L 2 5 A l F &

S........

.. t+-

.. s i

........ M 2 0 : 4 P........

+

..... -. C a

.....t...... C u +

+ + +:

+.

+

........ M O.....

a Z n I K0 C1 1 0

--- + ---------

-.A+

+. ------
+.* _+.

+....

5 Olt 2

i

~

4--

.........." + ÷- + +. + * +,. - -! + *.

0 100 200 300

400, 500 60Q 700 80(

Time (h)

Figure 30.2.22-4: Solution ICP Data vs Time QI z

0

-j

-13.0

-14.0

-15.0

-16.0

+

T(C)

-4 Lo K(Na)(AI)(Si)3 Fl**

log Ksp(low albite)

"-** "_<+

Sodium aluminum silicate

[rof. Am, J. Sc6, 299, 173-209 (1999)]

-\\SEBOG rm-tm 90 85 80 75

-I 70 (0 65 60 55 50

-17.0

-18.0

-19.0

-20.0 0

100 200 300 400 500 600 700 Time (h)

Figure 3o.2.22-5: Potential Sodium Aluminum Silicate in Solution vs. Solubility (from ICP data)

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 65 of 89

-15,0 I

I

-16.0 -

Log K (Na)(AI)(Si) 3 0-J

-17.0

-18.0 -

'F-3 0

log Ksp (low albite)

-19.0 -Sodium.aluminum silicate

[ref: Am. J. Sci. 299,173-209 (1999)]

-20.0 1

1I I

90 85 80 75 70 65 60 55 50 T(C)

Figure 30.2.22-6: Potential Sodium Aluminum Silicate in Solution vs. Solubility (as a function of Temperature)

From Figure 3o.2.22-7 and Figure 3o.2.22-8 it is apparent that the potential for chemical effects associated with NAS and the increase in head loss occurs at the very beginning of the test.

There is also an increase in head loss during the buffer addition at 87 deg C.

7,0 I

I I

I o~60 CBU 1.4

-" 6.0 (ref = 0.22: kPa) 1,.2 5.0 E

.0.8 u*

3.0 0.6 S2.0 X

0.4

,4) 0.4 90 85 80 75 70 65 60 55 50 TemperatUre (C)

Figure 3o.2.22-7: Chemical Bump up Factor/Head Loss versus Temperature

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 66 of 89 7.0 0

LL C.

E.

(2 6.0 5.0 4.0 I

I I

I I

I TPN-3.VUEZ. Test CBU w/T effect Log K [(Na)(AI)(Si)J CBU w/o T effect Log Ksp (low albite)

I I

I I

I

-13.0 1-14.0 0

-15.0

-16.0

-17.0 3.0 2.0 1.0 0.0

-18.0

-19.0

-20.0 I-0 0

100 200 300 400 500 600 700 Time (hr)

Figure 3o.2.22-8: Composite Plot of CBU versus Time, Temperature, and NAS From this test it is clear that most of the.chemical effects occur as a result of the buffer addition.

The long term increase in head loss due to chemical effects is from 3.0 to 3.75 results from the degradation of the debris bed combined with a nominal amount of sodium aluminum silicate.

The results of the PTN-3 chemical effects testing have provided a chemical effects increase of 3.75x over that of the non-chemical effects head loss for the limiting plant specific bed evaluated. Most of this increase occurred relatively early from the results associated with bed dissolution and compaction in the thin bed case. The long term chemical effects increases were not significant ranging from 3.0 to 3.75x over that of the non-chemical effects head loss.

The results of this chemical evaluation result in a conservative application of a chemical bump up factor based on the early rise in dP from the test data. The reality of immediate chemical effects under this relatively neutral environment is most likely overestimated since corrosion and solubility products are not significant at this time. Most of the increase in head loss from this test is due to bed degradation over time. Applying this bump-up factor over the course of the entire time/temperature range does yield conservative results.

[RAI 2] The Integrated Chemical Effects Test Project Test #5 Data Report is most applicable to the current plant specific conditions at Turkey Point Unit 3.

The comparison is as follows:

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 67 of 89 Table 3.o-1 Comparision of PTN-3 to ICET Test #5 Material Value of Ratio for PTN 3 Total Amount PTN 3 Ratio' ICET values for submerged and the Test unsubmerged Zinc in Galvanized Steel 8.0 (ft1/ft*)

70,000 ftW 2.2 (ft;/ft")

5% submerged 10% submerged 95% unsubmerged 90% unsubmerged Inorganic Zinc Primer Coating 4.6 (ftl/ftJ) 5000 ft1 0.16 (ftzlft*)

(non top coated) 10% submerged 4% submerged 90% unsubmerged 96% unsubmerged Aluminum 3.5 (ft1/ft )

51,740 ftC 1.6 (ft1/ft*)

5% submerged 7.5% submerged 95% unsubmerged 92.5% unsubmerged Copper 6.0 (ft2/ft*)

3452 ftf 0.11 (ftW/ft4)

(including Cu-Ni alloys) 25% submerged 75% unsubmerged Carbon Steel 0.15 (ft1/ft*)

100 ft2 0.00 (ft2/ftc) 34% submerged 10% submerged 66% unsubmerged 90% unsubmerged Concrete (uncoated) 0.045 (ftWIftW) 1300 ft1 0.26 (ft1/ft1) 34% submerged 60% submerged 66% unsubmerged 40% unsubmerged Note: 1. Minimum volume of water at the start of recirculation was assumed to be 32,136 ft3.

As indicated by the table, the quantities of materials used in the Integrated Chemical Effects Test Project Test #5 Data Report bound the actual conditions at PTN 3 with the exception of exposed concrete surface area.. Strainer testing was performed using the plant specific quantities of materials.

[RAI 3] For Turkey Point Unit 3 (PTN-3), the small amount of carbon steel knuckles and aluminum ladders stored in the containment are included in the debris quantities used for design inputs used to perform the chemical effects testing. The carbon steel DBA-qualified coated scaffold poles are not considered as a contributor for chemical testing.

PTN-3 currently has approval for scaffolding poles and connector storage in containment during power operation for 2549 square-feet of scaffold poles and 555 square-feet of galvanized steel connectors. Only scaffolding poles that have a DBA-qualified coating applied in accordance with the Coatings Specification are allowed in containment. The majority of the scaffolding is permanently secured in place per plant seismic requirements while some may be stored in scaffold storage racks. Scaffold storage racks are seismically qualified and coated with DBA-qualified coatings per the Coatings Specification.

Forty scaffold poles are stored at the 14'-0" elevation in the vertical position, secured inside of two W-shape columns, and seismically secured during plant operation. The connecting knuckles are galvanized steel and are permanently installed or stored in some or all of the approved seismically restrained 30-gallon stainless steel barrels. The barrels are sealed and are not a concern for exposure to

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 68 of 89 containment spray or immersion in floodwater.

One (1) stainless steel barrel is approved for location on the 14'-0" elevation, three (3) on the 30'-6" elevation and one (1) on the 58"-0" elevation. The amount of steel knuckles approved for installation and storage in containment is approximately 555 square-feet, and these are either permanently installed, or are contained in the referenced stainless steel sealed steel barrels.

Four hundred (400) linear feet of scaffold poles are approved for storage on the 14'-0" elevation and are stored in a vertical position. The scaffold pole ends would be submerged in the event of a LOCA. For the permanently installed connectors, less than 5 square feet of galvanized steel knuckles would be submerged in LOCA floodwater which has been evaluated to be negligible with respect to containment hydrogen generation. The galvanized steel knuckles stored in a single 30-gallon stainless steel sealed barrel on the 14'-0" elevation is not a concern since it is sealed. The calculated flood water level is 17.35' post LB-LOCA. There would be no adverse affect due to coatings to the Containment Spray (CS) and Emergency Core Cooling System (ECCS) since only an insignificant amount of galvanized knuckles are submerged and all the scaffolding poles are coated with DBA-qualified coatings.

Six (6) steel DBA-qualified coated ladders are permanently installed in the containment building.

The steel ladders are installed on the 58'-0" elevation for Steam Generator A, B & C inspection ports. Storage is approved for two aluminum ladders on the 58 foot elevation of the containment building. The total square footage of the aluminum ladder surface area is approximately 100 square feet. These ladders are above the LOCA flood level of 17.35' feet and there is no adverse impact to the CS and ECCS.

[RAI 4] Not applicable; there is no metallic paint or non-stainless steel insulation jacketing that is not included in the response to RAI 2.

[RAI 5] The minimum pH immediately following a LOCA is 4.95. The final pH is achieved by manual addition rather than an automatic addition by fixed chemicals. The EOPs direct addition of the buffer until a pH of 7.2 is obtained. Thus, the beginning or end of a fuel cycle is not relevant.

[RAI 6] The ICET environment most similar to TP-3 is ICET#5. Turkey Point 3 contains both calcium silicate and fibrous insulation with a sodium Tetraborate (NaTB) buffered environment.

The significant difference between Turkey Point -3 and ICET#5 is the upper range of pH.

Turkey Point -3 design basis supports a maximum pH of 7.2. Based on this lower pH, the impact of aluminum corrosion and subsequent chemical effects should be considerably less than that exhibited in ICET#5.

Table RAI 6-1:

Comparison of TP-3 and ICET#5 Environments Chemical Parameters Turkey Point -3 ICET#5 Boron Concentration 2,350 ppm 2,800 ppm Buffer Sodium Tetraborate Sodium Tetraborate Buffer Concentration As required to reach As required to reach

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 69 of 89 target profile of 7.2 boron concentration of 2400 ppm pH 7.2 8.2 to 8.4

[RAI 7] The time until ECCS external recirculation initiation is approximately 30 minutes (see Topic 3.g, Net Positive Suction Head). The associated pool temperature is shown in Figure 3.o.2.18-2 above. The pool volume is provided in Table 3.g-1.

[RAI 8] The information on the FPL Turkey Point Unit 3 Chemical Effects Testing Program is provided in Sections 3.o.1 thru 3.o.2.22.

[RAI 9] [RAI 15] At the time of the September 1 response, it was planned to change the buffering agent from sodium tetraborate (borax) to tri-sodium phosphate (TSP). Subsequently, in consideration of results from the industry Integrated Chemical Effects Tests (ICET), it has been decided to retain borax as the buffering agent. Nukon insulation was replaced with reflective metal insulation during the outage in which the strainers were installed. There are no future plans to remove materials from the containment building or make a change from the existing chemicals that buffer containment pool pH following a LOCA.

[RAI 10] FPL has completed chemical effects bench testing to provide insight into the dissolution and corrosion of these materials in a combined, integrated post-LOCA environment.

The benchtop testing was performed and provided by Alion Science & Technology and was generic in development similar to ICET and WCAP testing.

The benchtop testing was performed prior to the Turkey Point Unit 3 plant-specific 30-day integrated head loss testing and was intended to provide an expectation of what might form in the plant specific 30 day testing as compared to the ICET#5 testing.

The tests investigated the dissolution and corrosion of Aluminum, Zinc, Temp Mat, Cal-Sil, Nukon, and concrete in NaTB-containing solutions at pH 7.5 - 7.8; and the potential formation of chemical precipitates from these reactions at elevated temperature and chemical conditions that simulate post-LOCA conditions for a typical nuclear power plant. The test materials and solutions were visually examined and analyzed by ICP-AES, respectively.

The bench tests were performed in 350 mL boric acid solutions 2800 ppm of Boron and 0.7 ppm of Lithium (as LiOH) with NaTB buffer targeting a pH in the range of 7.5 - 7.8. The solution temperature was initially set at 200°F + 5°F for the first several hours followed by a decrease in temperature to 140'F + 5°F which was maintained for the remainder of the 30 day test. Table 3-1 shows the material to pool volume ratios for the benchtop tests.

Test 1: Aluminum, Zinc, Concrete, Temp-Mat, Cal-Sil, and Nukon in NaTB (Test 223-1 Test 2: Aluminum, Zinc, Concrete, Temp-Mat, Alkyd Paint, Dirt/Dust in NaTB (Test 214-4)

Table RAI 10-1:

Comparison of Material Surface to Pool Volume Ratios Containment Turkey Benchtop Benchtop Units Materials Point -3 Test 1 Test 2 Aluminum 1.6 0.04 0.3 ft2/ft3

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 70 of 89 Table RAI 10-1:

Comparison of Material Surface to Pool Volume Ratios Containment Turkey Benchtop Benchtop Units Materials Point -3 Test 1 Test 2 Zinc in Galvanized 2.3 0.6 0.9 ft2/ft 3 Steel Zinc Coatings 4.2 0.0 0.0 ft2/ft 3 Carbon Steel 0.003 0.0 0.0 ft2/ft 3 Temp-Mat 0.0 0.003 0.002 ft3/ft 3 NUKON 1.5E-4 0.027 0.0 ft3/ft 3 Cal-Sil 0.0017 0.0015 0.0 ft3/ft 3 Microtherm 7.2E-5 0.0 0.0 ft3/ft 3 Concrete Surface 0.04 0.047 3.48 ft2/ft 3 Solution samples were taken at the intervals specified in the test plan and coupons and fibers were analyzed to determine elemental compositions. It should be noted that the scaling of the benchtop testing were not identical to Turkey Point 3, but reasonable for the purpose of identifying visual precipitation and solution analyses.

Overall, the benchtop tests identified no precipitate formation similar as that confirmed in NUREG/CR-6913. Test 1 has the highest applicability because it was performed at a pH closest to Turkey Point 3. The benchtop tests were monitored for visual observations and test solutions, materials, and reaction products were examined by ICP-AES and EPMA.

The solutions remained relatively clear for the entire duration of the benchtop test. In addition, after each sample was taken it was observed that the solution remained clear as the solution cooled which suggests that no precipitation formed. The test materials after removal from the test solution showed some dark discoloration on the aluminum coupons which most likely the oxidation due to water condensation and the lack of buffer available at the metallic air/liquid interface.

Since the pH for Turkey Point Unit 3 is 7.2, the results of benchtop Test 1 (pH 7.5-7.8) are expected to be most applicable to Turkey Point 3. This benchtop program evaluated Aluminum, Zinc, Temp Mat, Cal-Sil, Nukon, and Concrete corrosion and dissolution in the NaTIB environment with a pH of 7.5 -7.8 and can make the following conclusions with respect to Test 1:

1)

No visible precipitation was noted during the test.

2)

Aluminum dissolution is minimal under near neutral pH conditions.

3)

Si and Al ICP levels are low which may be because of silicate inhibition of aluminum corrosion is occurring in the form of Si depositing on the aluminum substrate.

4)

Al ICP levels are reducing over time which may also indicate that the Al is being used to form precipitate on the fibers.

From these results, it is concluded that chemical effects (corrosion and precipitation) in the Aluminum, Zinc, Temp Mat, Cal-Sil, Nukon, and Concrete in the NaTB environment are negligible which is expected for these conditions.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 71 of 89 The benchtop program was not designed to address uncertainties in chemical effects head loss but to provide insight into the chemical reactions that would take place prior to performing an integrated 30 day chemical effects head loss test. Ultimately, Turkey Point 3 performed an integrated chemical effects head loss test with plant specific values that maximized the potential for corrosion products (pH, temperature). Benchtop results as well as other industry testing have confirmed that lower pH values provide lower corrosion. The values utilized in the Turkey Point 3 integrated 30-day test were consistent with the plant scaling parameters. No chemical surrogates were used in the Turkey Point 3 chemical effects head loss testing.

The results of the Turkey Point 3 chemical effects testing have provided a chemical effects increase of 3.75x over that of the non-chemical effects head loss for the limiting plant specific bed evaluated. Most of this increase occurred relatively early from the results associated with bed dissolution and compaction in the thin bed case. The long term chemical effects increases were not significant ranging from 3.0 to 3.75x over that of the non-chemical effects head loss.

The 30-day head losses and increases (bump-up factor CBU) are provided in Figures 3-1 and 3-2.

6.0 o 5.0 4.0 3.0 n S20~

2.0 1-0 1,.0 TPN-3.VUEZ.Test

.........TIRC5.1 [st.C]*1

E.

1_FJ

____ PDIR5.1 [KPa]

PDIR5.2 [KPa]

F..............

F IR S.[Im i ]

-.0 Bump up Factor W(ref

= 0.22 kPa) 80

  • 0 50 (D

50 7.0 6.0 50 E

3.0 M

2.0 E

1.0 4)

TPN-3.VUEZ. Test CBU wrr effect r*"*,5-S..,*

Log K [(Na)(AI)(Si)j]

CBU w/0 T effect Log Ksp (low albile)

-13.0 r-

-14.0 0

-15.0

-16.0

-17.01"0

-18.0 0

-20.0 0.0 U.U

  • U 0

100 200 300 400 500 600 700 Time (hr)

Figure 3-1: PTN-3 Head Loss Test Results 0

100 200 300 400 500 800 700 Time (hr)

Figure 3-2: PTN-3 Head Loss Increase Factor The results of this chemical evaluation result in a conservative application of a chemical bump up factor based on the early rise in dP from the test data. The reality of immediate chemical effects under this relatively neutral environment is most likely overestimated since corrosion and solubility products are not significant at this time. Most of the increase in head loss from this test is due to bed degradation over time. Applying this bump-up factor over the course of the entire time/temperature range does yield conservative results.

[RAI 11] ALION Science & Technology performed 30 day integrated chemical effects head loss testing at the VUEZ Test Facility in VUEZ, Slovakia.

As stated, Turkey Point -3 is only minimally represented by ICET Test #5, as ICET #5 contained significant amounts of NUKON fiberglass insulation. WCAP-16530-NP and WCAP-16785-NP computer analyses postulated that the precipitate material is Sodium Aluminum Silicate (NaAlSi308) and Aluminum Oxyhydroxide (AIOOH) because of the excess dissolved aluminum.

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 72 of 89 As noted, however, the WCAP model may over predict the Al release with silica in solution -

PTN-3 does contain a considerable amount of silica not to mention a relatively neutral pH with NaTB.

To determine the impact of sump chemistry and this precipitate on debris head loss, an integrated chemical effects head loss test was designed based on the ICET configuration. This test would allow for the direct measurement of the debris head loss during the 30-day mission time through the sump environmental history - essentially, ICET plus head loss testing.

The purpose of the Turkey Point 3 30 Day Chemical Effects (CE) debris head loss test program is similar to the ICET program but has also evaluated (measured) the impacts of chemical corrosion products and chemistry on the debris head loss over the 30-day sump history. The major differences between the programs is that the ICET program had no provisions for measuring head loss across the debris bed and held the temperature profile constant at 140 0F, whereas the PTN-3 testing included head loss measurements and included a specific temperature profile ranging from 190°F down to approximately 125 0F.

Integrated CE Head Loss Test Configuration and Set-up The test was conducted in a vessel (Figure 4-1) with representative structural materials, insulation and debris samples included in the simulated containment environment, their quantities scaled to preserve the PTN-3 specific conditions. Representative debris samples were placed in the vessel in a chemically non-reactive container that allows water to flow in the region of the samples while confining the material. Test conditions, i.e., material quantities and containment environment were PTN-3 specific and chosen to maximize the amount of chemical effects within realistic plant limits (temperature, pH, etc.). The technical basis for scaling plant specific debris quantities to the test quantities is developed and documented under separate calculations.

The test tank has appropriate temperature control such that temperatures of the simulated sump fluid follows the time-temperature profile that matches the plant estimated temperature profile to within +/-5 OF. The maximum temperature of the test tank is 190 0F. The test temperature profile and amount of added materials were modified to account for the release of materials associated with the early portion of the accident where the plant sump temperature is in excess of 190'F.

The initial make-up of the solution within the tank replicates that which is assumed to occur at the start of a post-LOCA event. Buffer was added to the test tank at an appropriate conservative rate as it is expected to be introduced into the containment environment over approximately 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />. Once sufficient buffer was added, no further pH adjustment was made, i.e., system pH was not artificially maintained at a certain level, but instead allowed to seek its own equilibrium level due to corrosion, etc., Based on bench-top testing and ICET results, pH does not change appreciably throughout the 30 day test once initial equilibrium is reached.

Within the test tank is a screen that was loaded with appropriately scaled quantities of the plant specific debris mixture. The screen used in the 30-day test is representative of the same design and materials as used for the actual plant strainers. The coolant was circulated through

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 73 of 89 the debris bed at the same approach velocity-as the new strainer approach velocity. Head loss measurements across the debris bed were recorded continuously for the duration of the test.

The test was designed to replicate the amount and rate of release of those elemental materials within containment that are potentially responsible for the formation of precipitates. Small samples of fluid were taken at regular intervals and analyzed for various metals (Al, Ca, Cu, Fe, Ni, Na, Si, and Zn) by AES ICP spectroscopy. Upon conclusion of the test, the mass of the metal coupons, and their general condition were recorded and compared to their initial state. In addition, debris bed samples were analyzed using SEM/EDS techniques.

Figure 4-1: Test Reactor (Quantity 6 in a row)

The chemical fluid environment of the test was similar to that of plant in that it included boron, hydrochloric and nitric acid, lithium hydroxide and buffer to match the plant specific conditions.

The only limitation on the test was the maximum test temperature (190 deg F). Corrosion for temperatures greater than 190 deg F was accommodated by adding additional metal and concrete coupons and fiberglass materials to ensure the total release of materials at the lower temperature was equivalent to that of the higher plant specific profile (only for temperatures greater than 190 deg F). These temporary materials were removed at predetermined times.

No chemical surrogates were utilized in this test and the corrosion products generated within the integrated test are expected to be similar to those generated under plant post-LOCA conditions. The test is similar to ICET but more representative of specific plant conditions along with capability of real time head loss measurements over the 30 day mission time.

[RAI 12] This RAI requested FPL provide the maximum projected head loss resulting from chemical effects (a) within the first day following a LOCA, and (b) during the entire ECCS recirculation mission time. The overall chemical effects testing program is discussed in section 3.o and the resulting NPSH is discussed in Topic 3.g, Net Positive Suction Head. Note that the full 30 day debris load (non chemical debris and the maximum bump up factor) is applied at the initiation of recirculation. This is extremely conservative because, as the chemical products are

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 74 of 89 being created during the 30 days, the sump pool is cooling down providing additional NPSH margin.

[RAI 13] The light precipitates were visible after the test solution sat at room temperature for several days. The aluminum concentration for ICET#5 was approximately 40 to 55 ppm at a pH of 8.5. The aluminum concentration for PTN-3 is below 10 ppm at a pH of 7.2. Turkey Point -3 does not directly utilize the results of ICET#5 and has evaluated the impact of chemical effects for 30 days down to the minimum plant temperature of 100 deg F.

Turkey Point Unit 3 L-2008-138 Docket No. 50-250 Page 75 of 89 Topic 3.p: Licensinq Basis FPL Response The UFSAR and Technical Specification Bases have been updated to incorporate the effects of plant modifications and evaluations performed in accordance with the requirements of 10 CFR 50.59. The requested actions described in GL 2004-02 where addressed for Turkey Point Unit 3 without the need for changing the plant technical specifications.

The Technical Specification Bases were updated to expand the definition of the recirculation sump inspection requirements to include the entire distributed sump strainer system. This change ensures that the entire system will come under the technical specification requirements for sump inspection and control.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 76 of 89 (Turkey Point Unit 3 Updated Supplemental Response)

NRC Safety Evaluation Report Limitations and Conditions for WCAP 16406-P Revision 1

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 77 of 89 L&C No.

NRC Limitations & Conditions (WCAP-1 6406-P, Rev 1)

FPL (Turkey Point Unit 3) Response 1

Where a TR WCAP-16406-P, Revision 1, section or General WCAP-16406-P examples and appendix refers to examples, tests, or general technical technical data were not used for site specific data, a licensee should compare and verify that the input. The wear equations developed in the information is applicable to its analysis.

WCAP-16406-P based on tests and general technical data were developed and benchmarked on equipment and with debris similar to that found at PTN-3. The wear equations were adjusted for the specific materials and debris concentration at PTN-3.

2.

A discussion of EOPs, AOPs, NOPs or other plant-The downstream effects analysis for PTN-3 reviewed alternate system line-ups should be included in considered all procedural recirculation system the overall system and component evaluations as noted line-ups that are used by the plant, including any in the NRC staffs SE of NEI 04-07, Section 7.3 alternate line-ups. Analysis of components in (Reference 13).

the alternate flowpaths was performed for the full recirculation mission time, like the primary flowpath components. The system evaluation discusses the procedures and alternate system line-ups.

3.

A licensee using TR WCAP-16406-P, Revision 1, will The downstream effects analysis uses a need to determine its own specific sump debris mixture bounding site-specific sump debris mixture and and sump screen size in order to initiate the evaluation, the actual sump strainer hole size. Since site specific debris bypass test data were not available, the WCAP-16406-P methodology of strainer efficiency and retention size were utilized. The assumed maximum particulate size capable of passing the strainer was altered from the suggested WCAP-16406-P approach.

Fibrous debris was modeled as completely depletable based on strainer capture efficiency, only. Debris size distribution was determined based on experimental data (not site specific) and the PTN-3 specific debris types were used.

4.

TR WCAP-16406-P, Revision 1, Section 4.2, provides a Recirculation operation is analyzed for 30 days general discussion of system and component mission post-LOCA. The mission time of all components times. It does not define specific times, but indicates that is 30 days unless the plant's recirculation the defined term of operation is plant-specific. As stated procedures limit the time that specific in the NRC staffs SE of NEI 04-07, Section 7.3 components are used. The 30 day recirculation (Reference 13), each licensee should define and provide duration is based on the SE of NEI 04-07, and adequate basis for the mission time(s) used in its was reviewed and found to be consistent (does downstream evaluation.

not conflict) with the PTN-3 design and licensing basis.

5.

TR WCAP-16406-P, Revision 1, Section 5.8, assumes PTN-3 utilizes lower plenum injection.

that the coolant which is not spilled flows into the reactor system and reaches the reactor vessel downcomer. This would be true for most PWR designs except for plants with UPI. Therefore, the methodology of Section 5.8 may not be applicable to plants with UPI and its use should be justified on a plant-specific basis.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 78 of 89 L&C No.

NRC Limitations & Conditions (WCAP-16406-P, Rev 1)

FPL (Turkey Point Unit 3) Response

6.

TR WCAP-16406-P, Revision 1, Section 5.8, provides The initial particulate debris concentration was equations which a licensee might use to determine determined for PTN-3 based on a plant-specific particulate concentration in the coolant as a function of limiting debris loads and sump water volumes.

time. Assumptions as to the initial particulate debris Debris depletion in the calculations is based on concentration are plant-specific and should be plant specific flows, debris types and debris determined by the licensee. In addition, model concentrations. The size of debris subject to assumptions for ECCS flow rate, the fraction of coolant settling in the lower plenum was determined on spilled from the break and the partition of large heavy a plant-specific basis; the ECCS flows and particles which will settle in the lower plenum and smaller spillage assumed are the most conservative for lighter particles which will not settle should be determined this purpose.

and justified by the licensee.

7.

TR WCAP-16406-P, Revision 1, Sections 5.8 and 5.9, The site specific debris settling size is assumes that debris settling is governed by force balance determined in calculations which were according methods of TR Section 9.2.2 or Stokes Law. The effect of to force balance methods. The methodology debris and dissolved materials on long-term cooling is uses empirical friction factors based on the being evaluated under TR WCAP-16793-NP (Reference debris shape. This methodology is 12). If the results of TR WCAP-1 6793-NP show that benchmarked against the NRC-sponsored debris settling is not governed by force balance methods testing of paint chip settling reported in of TR Section 9.2.2 or Stokes Law, then the core settling NUREG/CR-6916.

term determined from TR WCAP-16793-NP should be used.

8.

TR WCAP-16406-P, Revision 1, Section 7.2, assumes a Analysis was performed for a mission time of mission time of 720 hours0.00833 days <br />0.2 hours <br />0.00119 weeks <br />2.7396e-4 months <br /> for pump operation. Licensees thirty days following initiation of LBLOCA event.

should confirm that 720 hours0.00833 days <br />0.2 hours <br />0.00119 weeks <br />2.7396e-4 months <br /> bounds their mission time No reduction in mission time is credited in this or provide a basis for the use of a shorter period of analysis. The use of a full thirty day mission required operation.

time is consistent with NEI 04-07 and its NRC SER, and the UFSAR. Additionally, use of a 30 day mission time is consistent with the time periods anticipated in NUREG 0800, Section 9.2.5, Ultimate Heat Sink. Reasonable and prudent management and operator action is credited for any actions required beyond thirty days to ensure continued safe operation of needed ECCS and CSS pumps. The mission time of individual components was a full 30 days except where the plant's recirculation procedures limit the time that specific components are used.

9.

TR WCAP-16406-P, Revision 1, Section 7.2, addresses Calculations consider the maximum of either wear rate evaluation methods for pumps. Two types of free-flow or packing type abrasive wear until a wear are discussed: 1) free-flowing abrasive wear and 2) wear ring clearance of 50 mils diametral is packing-type abrasive wear. Wear within close-tolerance, reached. Beyond that time, the packing is high-speed components is a complex analysis. The assumed expelled and free-flow wear (abrasive actual abrasive wear phenomena will likely not be either a and erosive) is modeled.

classic free-flowing or packing wear case, but a combination of the two. Licensees should consider both in their evaluation of their components.

10:

TR WCAP-16406-P, Revision 1, Section 7.2.1.1, Debris depletion coefficients in the calculations addresses debris depletion coefficients. Depletion are based on plant specific flows, debris types coefficients are plant-specific values determined from and debris concentrations and the strainer plant-specific calculations, analysis, or bypass testing.

design. The ECCS flows and spillage assumed Licensees should consider both hot-leg and cold-leg are the most conservative for this purpose of break scenarios to determine the worst case conditions either cold or hot-leg break scenarios. The for use in their plant specific determination of debris calculated plant-specific depletion coefficient is depletion coefficient.

only utilized where it is lower than (i.e., more conservative) the WCAP-16406-P lower-limit values.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 79 of 89 L&C No.

NRC Limitations & Conditions (WCAP-16406-P, Rev 1)

FPL (Turkey Point Unit 3) Response

11.

TR WCAP-16406-P, Revision 1, Section 7.3.2.3, Wear of elastomeric materials, reduced by a recognizes that material hardness has an effect on factor of 10, is not applicable to any of the erosive wear. TR WCAP-1 6406-P, Revision 1, suggests downstream effects wear calculations.

that "For elastomers, the wear rate is at least one order of magnitude less than steel. Therefore, for soft-seated valves, divide the estimated wear rate of steel from above equations by 10 per Appendix F." The NRC staff agrees that the wear rates of elastomers are significantly less than for steels. However, the wear coefficient should be determined by use of a suitable reference, not by dividing the steel rate by a factor of 10.

12.

TR WCAP-16406-P, Revision 1, Section 8.1.1.2, Non-mechanistic failure of an ECCS or CSS "Evaluation of ECCS Pumps for Operation with Debris-pump seal is considered as a single-failure in Laden Water from the Containment Sump," states that the plant design basis and is acceptable. The "Sufficient time is available to isolate the leakage from the WCAP-16406-P attempts to justify failure of the failed pump seal and start operation of an alternate seals due to recirculation debris, which is a ECCS or CSS train." Also, Section 8.1.3, "Mechanical potential common-mode failure. The pump seals Shaft Seal Assembly," states: "Should the cooling water at PTN-3 have been evaluated as not to the seal cooler be lost, the additional risk for seal susceptible to failure by debris-laden water, the failure is small for the required mission time for these LHSI and HHSI pump seals recirculate seal pumps." These statements refer only to assessing seal cavity fluid while the CS pump seal injection of leakage in the context of pump operability and 10 CFR process fluid was evaluated as acceptable for Part 100 concerns. A licensee should evaluate leakage in long-term recirculaiton. Therefore the only the context of room habitability and room equipment potential failure that must be considered is an operation and environmental qualification, if the assumed single failure, which again is part of calculated leakage is outside that which has been the existing design basis of the plant (bounded previously assumed.

by a moderate energy line break in the pump room). The potential effect of debris causing an increased leakage flow through the disaster bushing following that single-failure has been evaluated and determined to be acceptable.

13.

TR WCAP-16406-P, Revision 1, Section 8.1.3, discusses The CS pump seal injection uses a cyclone cyclone separator operation. TR WCAP-1 6406-P, separator. Plant-specific evaluation of the pump Revision 1, generically concludes that cyclone separators seal during accident operation determined that it are not desirable during post-LOCA operation of HHSI was acceptable for long-term recirculation pumps. The NRC staff does not agree with this generic based on the cyclone separator design and the statement. If a licensee pump contains a cyclone fibrous debris load it would see.

separator, it should be evaluated within the context of both normal and accident operation. The evaluation of cyclone separators is plant-specific and depends on cyclone separator design and the piping arrangement for a pump's seal injection system.

14.

TR WCAP-16406-P, Revision 1, Section 8.1.4, refers to The pump wear analysis assumes 30 days of pump vibration evaluations. The effect of stop/start pump continuous wear. PTN-3 procedure does not operation is addressed only in the context of clean water direct to stop then start the ECCS/CSS pumps operation, as noted in Section 8.1.4.5 of TR WCAP-during recirculation. In the event the pumps 16406-P, Revision 1. If an ECCS or CSS pump is must be stopped and restarted, the Archard operated for a period of time and builds up a debris wear model assumed the highest friction factors "packing" in the tight clearances, stops and starts again, and eccentricity postulated by the WCAP-the wear rates of those areas may be different due to 16406-P. Therefore, any "additional packing" additional packing or imbedding of material on those wear that could be caused by stopping and starting surfaces. Licensees who use stop/start operation as part the pumps is bounded by the Archard model of their overall ECCS or CSS operational plan should used.

address this situation in their evaluation.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 80 of 89 L&C No.

NRC Limitations & Conditions (WCAP-16406-P, Rev 1)

FPL (Turkey Point Unit 3) Response 15.1 TR WCAP-16406-P, Revision 1, Section 8.1.4, states:

The plant's procedures were not changed to "should the multistage ECCS pumps be operated at flow reflect the WCAP-16406-P concerns. The PTN-rates below 40% of BEP during the containment 3 multistage pumps performed adequately with recirculation, one or more of the pumps should be respect to pump design and plant design basis secured to bring the flow rate of the remaining pump(s)'.,

before GSI-1 91 concerns. The pump above this flow rate." The NRC staff does not agree with assessment concludes that the HHSI pumps this statement. System line-ups and pump operation and continue to be capable of performing their operating point assessment are the responsibility of the intended design basis functions based on the licensee. Licensees must ensure that their ECCS pumps pump's hydraulic characteristics after 30 days of are capable of performing their intended function and the wearing.

NRC has no requirements as to their operating point during the recirculation phase of a LOCA.

16.

TR WCAP-16406-P, Revision 1, Section 8.1.5, makes a The pump wear analysis assumed a starting generic statement that all SI pumps have wear rings that wear ring clearance as the average of the are good "as new" based solely upon "very little service vendor recommended gap range. The beyond inservice testing." A stronger basis is needed to combination of low run time and very clean validate this assumption, if used (e.g., maintenance, test fluids would justify an assumption that the wear and operational history and/or other supporting data).

rings are "as good as new" and thus closer to the low end of the recommended ring clearance, but the wear calculation conservatively assumes that the wear rings are mid-way between the lower and the upper ring clearance recommended by the pump manufacturers.

17.

TR WCAP-16406-P, Revision 1, Section 8.3, identifies The minimum heat exchanger tube velocity was criteria for consideration of tube plugging. Licensees calculated and compared to the bounding should confirm that the fluid velocity going through the particle settling velocity. No heat exchangers heat exchanger is greater than the particle settling were found to be susceptible to debris settling velocity and evaluate heat exchanger plugging if the fluid within the tubes.

velocity is less than the settling velocity.

18.

TR WCAP-16406-P, Revision 1, Section 8.6, refers to The evaluation of instrumentation tubing was evaluation of instrumentation tubing and system piping.

based primarily on the instrument line's specific Plugging evaluations of instrument lines may be based on configuration, and then upon the local flow system flow and material settling velocities, but they must velocity for instrument lines oriented below the consider local velocities and low-flow areas due to horizontal datum. Plant-specific layout and specific plant configuration.

actual local flow velocities were used in all cases.

19.

TR WCAP-i 6406-P, Revision 1, Sections 8.6.7, 8.6.8, The PTN-3 RVLIS design was compared to the 8.6.9, and 8.6.10 describe, in general terms, the generic designs reviewed and deemed Westinghouse, CE, and B&W RVLIS. TR WCAP-16406-acceptable by the WCAP-16406-P. The plant P, Revision 1, recommends that licensees evaluate their design was found to be consistent, and specific configuration to confirm that a debris loading due therefore acceptable with regards to to settlement in the reactor vessel does not effect the '

recirculation operation. Turkey Point Unit 3 operation of its RVLIS. The evaluation of specific RVLIS utilizes a Heated Junction Thermocouple design and operation is outside the scope of this SE and System consisting of eight pairs of should be performed in the context of a licensees reactor heated/unheated thermocouples. Two pairs of fuel and vessel evaluations, thermocouples are located in the upper head region above the upper support plate and six pairs are located in the upper plenum region between the core alignment and support plates.

Since the probes are not in the lower plenum where debris could potentially settle, debris settling will not affect the operation of the RVLIS.

.1.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 81 of 89 L&C No.

NRC Limitations & Conditions (WCAP-16406-P, Rev 1)

FPL (Turkey Point Unit 3) Response

20.

TR WCAP-16406-P, Revision 1, Section 8.7, refers to ECCS and CSS system piping was checked for evaluation of system piping. Plugging evaluations of potential plugging due to debris settling. At each system piping should be based on system flow and control valve in the recirculation systems, the material settling velocities. Licensees should consider the minimum expected system flow rates in each effects of local velocities and low-flow areas due to line were used to minimize the flow velocity and specific plant configuration. A piping wear evaluation compared to the bounding settling velocity. The using the free-flowing wear model outlined in Section 7 evaluation at control valve locations considered should be performed for piping systems. The evaluation the local flow velocities of all the various line should consider localized high-velocity and high-sizes and flow rates used for recirculation in the turbulence areas. A piping vibration assessment should PTN-3 ECCS and CSS. All lines were found be performed if areas of plugging or high localized wear acceptable with respect to plugging. Regarding are identified.

wear, the material wear of the bounding ECCS/CSS orifice, which sees much higher wear than system piping, was compared to the pipe wall thicknesses in the recirculation lines.

The material wear was found to be insignificant compared to the pipe wall thickness. Therefore, all pipes were determined to have sufficient wear margin, and the erosion was considered so slight as to not require vibration analysis.

21.

TR WCAP-16406-P, Revision 1, Section 9, addresses Reactor internal and fuel blockage was reactor internal and fuel blockage evaluations. This SE evaluated utilizing WCAP-16793-NP and is summarizes seven issues regarding the evaluation of discussed in NRC Topic 3.n, Downstream reactor internal and fuel. The PWROG indicated that the Effects - Fuel and Vessel.

methodology presented in TR WCAP-16793-NP (Reference 15) will address the seven issues. Licensees should refer to TR WCAP-16793-NP and the NRC staff's SE of the TR WCAP-16793-NP, in performing their reactor internal and fuel blockage evaluations. The NRC staff has reached no conclusions regarding the information presented in TR WCAP-16406-P, Section 9.

22.

TR WCAP-16406-P, Revision 1, Table 4.2-1, defines a This WCAP-16406-P guidance was not utilized.

plant Category based on its Low-Head / Pressure Safety PTN-3 has single-failure tolerant hot-leg Injection to RCS Hot-Leg Capability. Figure 10.4-2 recirculation capability as part of the existing implies that Category 2 and 4 plants can justify LHSI for design and licensing basis. No credit was taken hot-leg recirculation. However, these categories of plants for a single hot-leg injection pathway as only have one hot-leg injection pathway. Category 2 and suggested by the WCAP-16406-P.

Category 4 plant licensees should confirm that taking credit for the single hot-leg injection pathway for their plant is consistent with their current hot-leg recirculation licensing basis.

23.

TR WCAP-16406-P, Revision 1, Appendix F, discusses The debris and wear models were component wear models. Prior to using the free-flowing conservatively applied to ensure that they abrasive model for pump wear, the licensee should show conservatively predict expected wear. Actual that the benchmarked data is similar to or bounds its pump dimensions, characteristics, and plant conditions.

materials, and the actual plant debris concentration was utilized-in predicting pump wear.

24.

TR WCAP-16406-P, Revision 1, Appendix H, references The pump calculations all assume that the American Petroleum Institute (API) Standard 610, Annex starting point for the wear rings is the midpoint 1 eighth edition. This standard is for newly manufactured of the manufacturers recommended ring pumps. Licensees should verify that their pumps are "as clearance (see #16, above). Since the pumps good as new" prior to using the analysis methods of API-rings are in new condition, the analysis methods 610. This validation may be in the form of maintenance of API-610 are applicable.

records, maintenance history, or testing that documents that the as-found condition of their pumps.

/

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 82 of 89 L&C No.

NRC Limitations & Conditions (WCAP-16406-P, Rev 1)

FPL (Turkey Point Unit 3) Response

25.

TR WCAP-16406-P, Revision 1, Appendix I, provides This SER limitation is simply a statement of the guidelines for the treatment, categorization and amount of limit of the NRC's review; no action is required.

DBA Qualified, DBA Acceptable, Indeterminate, DBA For reference, however, the amount of specific Unqualified, and DBA Unacceptable coatings to be used types of coatings used in the downstream in a licensee's downstream sump debris evaluation. A effects analysis was determined on a plant-technical review of coatings generated during a DBA is specific basis considering the types of coatings not within the scope of this SE. For guidance regarding actually in use in the PTN-3 containment. The this subject see the NRC staff's SE of NEI-04-07 methodology of NEI 04-07 and the SER thereto (Reference 13) Section 3.4 "Debris Generation."

was followed generally.

26.

TR WCAP-16406-P, Revision 1, Appendix J, derives an This approach that is "only applicable to approach to determining a generic characteristic size of screens" was only applied to the sump screens deformable material that will pass through a strainer hole.

(strainers in the case of PTN-3). The This approach is only applicable to screens and is not characteristic size of debris that can pass applicable to determining material that will pass through through the sump strainer was calculated and other close tolerance equipment.

then compared to the smallest passages of downstream components. The component was deemed acceptable where the smallest passage is larger than this characteristic size, in other words the deformation of the debris was not credited to allow it to pass the downstream close tolerances.

27.

TR WCAP-16406-P, Revision 1, Appendix 0, Section 2.2, The Archard model wear coefficient utilized in states that the wear coefficient, K, in the Archard Model is the PTN-3 HHSI pump wear analysis is the determined from testing. The wear coefficient (K) is more "conservative upper bound" suggested by the uncertain than the load centering approach and K may WCAP-1 6406-P and 5 times larger than the vary widely. Therefore, licensees should provide a clear value actually used in the WCAP-16406-P basis, in their evaluation, for their selection of a wear example. Its use resulted in calculated wear coefficient.

greater than the amount seen in the Davis-Besse testing. The materials, debris types and concentrations are comparable. Therefore, the K-value used appears to be the best conservative information available on ECCS pump wear when exposed to insulation and coating debris.

28.

TR WCAP-16406-P, Revision 1, Appendix P, provides a The methodology of Appendix P was not used in method to estimate a packing load for use in Archard's the determination of packing loads. The PTN-3 wear model. The method presented was benchmarked for calculation utilized the methodology discussed a single situation. Licensees are expected to provide a in Appendix 0 of WCAP-16406-P (centering discussion as to the similarity and applicability to their load) for defining loads to be used in the conditions. The licensee should incorporate its own packing wear model, and specific design specific design parameters when using this method.

parameters were applied to that methodology.

29.

TR WCAP-1 6406-P, Revision 1, Appendix Q, discusses 9.02E-5 (mils/hr)/10 PPM was not used as the bounding debris concentrations. Debris concentrations free flowing abrasive wear constant at the plant.

are plant-specific. If 9.02E-5 (mils/hr)/10 PPM is to be The wear rate was calculated for each pump's used as the free flowing abrasive wear constant, the actual material hardness and actual debris licensee should show how it is bounding or representative concentrations, including application of the of its plant.

bounding debris penalty as required.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 83 of 89 L&C No.

NRC Limitations & Conditions (WCAP-16406-P, Rev 1)

FPL (Turkey Point Unit 3) Response

30.

TR WCAP-16406-P, Revision 1, Appendix R, evaluates a Acceptance criteria and stiffness values from Pacific 11-Stage 2.5" RLIJ pump. The analysis was Appendix R were not used. All pump performed by the PWROG using specific inputs. ECCS calculations utilize plant specific information and pumps with running clearance designs and dimensions data to perform wear calculation and shaft significantly different than those covered by the analysis stiffness evaluations. Example data from the should be subjected to pump-specific analysis to WCAP-16406-P is not used in any calculation.

determine the support stiffness based on asymmetric The designs and dimensions of the PTN-3 HHSI wear. If licensees use the aforementioned example, a pumps were reviewed and found to not be similarity evaluation should be performed showing how significantly different than those covered by the the example is similar to or bounds their situations.

WCAP-16406-P analysis.

Multi-stage pumps were evaluated by finding the shaft stiffness at a symmetric increase in wear ring clearance equal to 2X as the as-new clearance. The stiffness of the pumps after debris induced wear was then calculated. The stiffness of the pumps after recirculation asymmetric wear was compared to the allowed stiffness equivalent to a uniform 2X initial clearance to judge the acceptability of the pump.

31.

Licensees should compare the design and operating The criteria and analysis specific for Pacific 2.5" characteristics of the Pacific 2.5" RLIJ 11 to their specific RLIJ 11 as shown in Appendix S were not used.

pumps prior to using the results of Appendix S in their As stated in response 30 above, all pump component analyses.

calculations utilize plant specific information and data to perform wear calculation and shaft stiffness evaluations. Example data from the WCAP-16406-P is not used in any calculation.

Multi-stage pumps were evaluated by finding the shaft stiffness at a symmetric increase in wear ring clearance equal to 2X as the as-new clearance. The stiffness of the pumps after debris induced wear was then calculated. The stiffness of the pumps after recirculation asymmetric wear was compared to the allowed stiffness equivalent to a uniform 2X initial clearance to judge the acceptability of the pump.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 84 of 89 (Turkey Point Unit 3 Updated Supplemental Response)

NRC Safety Evaluation Report Limitations and Conditions for WCAP 16793-NP Revision 0

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 85 of 89 L&C No.

NRC Limitations & Conditions (WCAP-16793-NP Rev. 0)

FPL (Turkey Point Unit 3) Response 1

WCAP-16793-NP states that licensees shall either The Turkey Point Unit 3 plant-specific fiber demonstrate that previously performed bypass testing is bypass testing was performed by the strainer applicable to their plant-specific conditions, or perform their vendor.

own plant-specific testing. The NRC staff agrees with this stated position.

2.

There are very large margins between the amount of core A plant specific analysis using the blockage that could occur based on the fuel designs and Westinghouse LOCA Deposition Model the debris source term discussed in the TR and the (LOCADM) was performed for Turkey Point blockage that would be required to degrade the coolant flow Unit 3. The results of the calculation yielded to the point that the decay heat could not be adequately a maximum fuel cladding temperature and removed. Plant-specific evaluations referencing TR WCAP-thickest calculated scale well below the 16793-NP should verify the applicability of the TR blockage threshold criteria.

conclusions to the licensees' plant and fuel designs.

(Section 3.2 of this SE)

3.

Should a licensee choose to take credit for alternate flow No alternative flow paths were used for paths such as core baffle plate holes, it shall demonstrate Turkey Point Unit 3. The flow paths are as that.the flow paths would be effective and that the flow described in WCAP 16793. No alternative holes will not be become blocked with debris during a loss-flow paths were utilized in the LOCADM.

of-coolant accident (LOCA) and that the credited flowpath would be effective.

4.

Existing plant analyses showing adequate dilution of boric The PWR Owners Group has a project to acid during the long-term cooling period have not develop the approach for boric acid considered core inlet blockage. Licensees shall show that precipitation analyses and evaluations, possible core blockage from debris will not invalidate the Project Number ACS-0264R1, Post LOCA existing post-LOCA boric acid dilution analysis for the plant.

Boric Acid Precipitation Analysis Methodology Program. The PWROG provided a response to the NRC for justification of continued operations. FPL will continue to follow the project developments.

5.

The staff expects the Pressurized Water Reactor Owners This L&C refers to information to be included Group (PWROG) to revise WCAP-16793-NP to address the in a revision to WCAP 16793-NP.

staff's requests for additional information and the applicant's responses. A discussion of the potential for fuel rod swelling and burst to lead to core flow blockage shall be included in this revision.

6.

WCAP-16793 shall be revised to indicate that the licensing Not Applicable. Turkey Point Unit 3 is not an basis for Westinghouse two-loop PWRs is for the upper plenum injection plant. The upper recirculation flow to be provided through the upper plenum plenum injection plants are Westinghouse injection (UPI) ports with the cold-leg flow secured.

two-loop PWRs. Turkey Point Unit 3 is a Westinghouse three loop plant.

7.

Individual UPI plants will need to analyze boric acid Not Applicable. Turkey Point Unit 3 is not an dilution/concentration in the presence of injected debris for upper plenum injection plant.

a cold-leg break LOCA.

8.

WCAP-16793 states that the assumed cladding oxide The Turkey Point Unit 3 LOCADM calculation thickness for input to LOCADM will be the peak local used the 17% cladding oxide thickness.

oxidation allowed by 10 CFR 50.46, or 17 percent of the cladding wall thickness. The WCAP states that a lower oxidation thickness can be used on a plant-specific basis if that value is justified. The staff does not agree with the flexibility in this approach. Licensees shall assume 17 percent oxidation in the LOCADM analysis.

9.

The staff accepts a cladding temperature limit of 8001F as The Turkey Point Unit 3 LOCADM calculation the long-term cooling acceptance basis for GSI-191 used 800°F as the cladding temperature limit.

considerations. Should a licensee calculate a temperature that exceeds this value, cladding strength data must be provided for oxidized or pre-hydrided cladding material that exceeds this temperature.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 86 of 89 L&C No.

NRC Limitations & Conditions (WCAP-16793-NP Rev. 0)

FPL (Turkey Point Unit 3) Response

10.

In the response to NRC staff requests for additional The Turkey Point Unit 3 LOCADM calculation information, the PWR Owners Group indicated that if plant-did not use plant-specific refinements for specific refinements are made to the WCAP-16530-NP chemical product generation, therefore, no base model to reduce conservatisms, the LOCADM user reduction in the chemical source term is shall demonstrate that the results still adequately bound present.

chemical product generation. If a licensee uses plant-specific refinements to the WCAP-16530-NP base model

,that reduce the chemical source term considered in the downstream analysis, the licensee shall provide a technical justification that demonstrates that the refined chemical source term adequately bounds chemical product generation. This will provide the basis that the reactor vessel deposition calculations are also bounding.

11.

WCAP-16793-NP states that the most insulating material The Turkey Point Unit 3 LOCADM calculation that could deposit from post-LOCA coolant impurities would used the deposit thermal conductivity value be sodium aluminum silicate. WCAP-16793 recommends of 0.11 BTU/hr-ft-°F. The Westinghouse that a thermal conductivity of 0.11 BTU/hr-ft-OF be used for LOCADM model listed a default value of 0.2 the sodium aluminum silicate scale and for bounding W/m-K, which is the metric equivalent of 0.11 calculations when there is uncertainty in the type of scale BTU/hr-ft-°F.

that may form. If plant-specific calculations use a less conservative thermal conductivity value for scale (i.e.,

greater than 0.11 BTU/hr-ft-°F), the licensee shall provide a technical justification for the plant-specific thermal conductivity. This justification shall demonstrate why it is not possible to form sodium aluminum silicate or other scales with conductivities below the selected value.

12.

WCAP-16793-NP indicates that initial oxide thickness and The Turkey Point Unit 3 LOCADM calculation initial crud thickness could either be plant-specific estimates used 17 percent of the cladding wall based on fuel examinations that are performed or default thickness for peak local oxidation allowed by values in the LOCADM model. Consistent with Conditions 10 CFR 50.46; see item #8 above. The and Limitations item number 8, the default value for oxide default value for the crud thickness used for used for input to LOCADM will be the peak local oxidation input to the LOCADM calculation was 140 allowed by 10 CFR 50.46, or 17 percent of the cladding wall microns, which is a more conservative value thickness. The default value for crud thickness used for than 127 microns.

input to LOCADM is 127 microns, the thickest crud that has been measured at a modern PWR. Licensees using plant-The 140 microns is the bounding crud specific values instead of the WCAP-16793-NP default thickness for all plants provided by values for oxide thickness and crud thickness shall justify Westinghouse.

the plant-specific values.

13.

As described in the Conditions and Limitations for WCAP-The Turkey Point Unit 3 LOCADM calculation 16530-NP (ADAMS ML073520891), the aluminum release applied a factor of two to the aluminum rate equation used in WCAP-16530-NP provides a release rate while maintaining the total reasonable fit to the total aluminum release for the 30-day aluminum release to that of the 30 day ICET tests but under-predicts the aluminum concentrations mission time.

during the initial active corrosion portion of the test. To provide more appropriate levels of aluminum for the The methodology for increasing the LOCADM analysis in the initial days following a LOCA, aluminum release rate by a factor of two was licensees shall apply a factor of two to the aluminum provided in additional guidance to the LOCA release as determined by the WCAP-16530-NP Deposition Model by Westinghouse.

spreadsheet, although the total aluminum considered does not need to exceed the total predicted by the WCAP-16530-NP spreadsheet for 30 days. Alternately, licensees may choose to use a different method for determining the aluminum release, but in all cases licensees shall not use a method that under-predicts the aluminum concentrations measured during the initial 15 days of ICET 1.

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 87 of 89 (Turkey Point Unit 3 Updated Supplemental Response)

NRC Safety Evaluation Report Limitations and Conditions for WCAP 16530-NP Revision 0

Turkey Point Unit 3 Docket No. 50-250 L-2008-138 Page 88 of 89 L&C No.

NRC Limitation & Condition (WCAP 16530 NP Rev. 0)

FPL (Turkey Point Unit 3) Response

1.

A peer review of NRC-sponsored chemical effects testing Not Applicable--This is not a limit or condition.

was performed and a number of technical issues related to GSI-191 chemical effects were raised by the independent peer review panel members (NUREG-1861). The peer review panel and the NRC staff developed a PIRT of technical issues identified by the peer review panel. The NRC staff is working to resolve the technical issues identified in the PIRT. Part of the resolution process includes NRC-sponsored analyses being performed by PNNL. Although the NRC staff has not developed any information related to the PIRT issues resolution that would alter the conclusions of this evaluation, some issues raised by the peer review panel were not completely resolved at the time this evaluation was written. An example of such an issue is the potential influences of organic materials on chemical effects. Therefore, it is possible that additional analysis or other results obtained during the resolution of the remaining peer review panel issues could affect the conclusions in this evaluation. In that event, the NRC staff may modify the SEor take other actions as necessary.

2.

This evaluation does not address TR WCAP-16785-NP, Not Applicable--This is not a limit'or condition.

"Evaluation of Additional Inputs to the WCAP-16530-NP FPL used the Pressurized Water Reactor Chemical Model." The NRC staff will provide comments on Owners Group (PWROG) methodology, which WCAP-16785-NP separate from this evaluation. In is in accordance with WCAP-16793-NP, addition, a separate SE will address a related TR, WCAP-Revision 0, to evaluate chemical effects in the 16793-NP, "Evaluation of Long-Term Cooling Considering reactor vessel.

Particulate, Fibrous, and Chemical Debris in the Recirculating Fluid." Chemical effects in the reactor vessel are not addressed in WCAP-16530-NP or in this SE.

Therefore, the approval of this TR does not extend to chemical effects in the reactor vessels.

If a licensee performs strainer head loss tests with Turkey Point Unit 3 did not perform strainer surrogate precipitate and applies a time-based pump head loss tests with surrogate precipitate or NPSH margin acceptance criteria (i.e., timed precipitate timed precipitate additions. The Alion VUEZ additions based on topical report model predictions), they chemical effects test program was used to must use an aluminum release rate that does not under-replicate head loss due to chemical effects.

predict the initial 15 day aluminum concentrations in ICET The program replicates the potential 1, although aluminum passivation can be considered interactions of the spray and pool fluid during the latter parts of the ECCS mission time in this chemistry with those materials and debris case.

sources in containment and resident on the sump screen.

For head loss tests in which the objective is to keep Turkey Point Unit 3 did not perform strainer chemical precipitate suspended (e.g., by tank agitation):

head loss tests in which the objective is to Sodium aluminum silicate and aluminum oxyhydroxide keep chemical precipitate suspended.

precipitate settling shall be measured within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of the time the surrogate will be used and the 1-hour settled volume shall be 6 ml or greater and within 1.5 ml of the freshly prepared surrogate. Calcium phosphate precipitate settling shall be measured within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of the time the surrogate will be used and the 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> settled volume shall be 5 ml or greater and within 1.5 ml of the freshly prepared surrogate. Testing shall be conducted such that the surrogate precipitate is introduced in a way to ensure transportation of all material to the test screen.

Turkey Point Unit 3 Docket No. 50-250 L--2008-138 Page 89 of 89 L&C No.

NRC Limitation & Condition (WCAP 16530 NP Rev. 0)

FPL (Turkey Point Unit 3) Response For head loss testing in which the objective is to settle Turkey Point Unit 3 did not perform strainer chemical precipitate and other debris: Aluminum head loss tests in which the objective is to containing surrogate precipitate that settles equal to or settle chemical precipitate and other debris.

less than the 2.2 g/l concentration line shown in Figure 7.6-1 of WCAP-16530-NP (i.e., 1-or 2-hour settlement data on or above the line) is acceptable. The settling rate shall be measured within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of the time the surrogate precipitate will be used.

For strainer head loss testing that uses TR WCAP-16530-Turkey Point Unit 3 did not utilize the testing NP sodium aluminum silicate and is performed in a de-methodology of WCAP-16530-NP.

ionized water environment, the total amount of sodium aluminum silicate added to the test shall account for the solubility of sodium aluminum silicate in this environment.