Category:Letter
MONTHYEARIR 05000324/20253012024-10-17017 October 2024 Notification of Licensed Operator Initial Examination 05000325/2025301 and 05000324/2025301 IR 05000324/20244012024-10-15015 October 2024 Security Baseline Inspection Report 05000324/2024401 and 05000325/2024401 ML24297A6262024-10-11011 October 2024 PCA Letter to NRC Brunswick Potential Tropical Storm Eight IR 05000324/20240102024-09-10010 September 2024 Focused Engineering Inspection Commercial Grade Dedication Report 05000324-2024010 and 05000325-2024010 ML24249A1362024-09-0404 September 2024 EN 57304 - Westinghouse Electric Company, LLC, Final Report - No Embedded Files. Notification of the Potential Existence of Defects Pursuant to 10 CFR Part 21 IR 05000324/20240052024-08-23023 August 2024 Updated Inspection Plan for Brunswick Steam Electric Plant, Units 1 and 2 (Report 05000324/2024005 and 05000325/2024005) IR 05000324/20240022024-08-0505 August 2024 Integrated Inspection Report 05000324/2024002 and 05000325/2024002 and 07200006/2024001 ML24206A1062024-07-30030 July 2024 2024 Brunswick Requal Inspection Corporate Notification Letter ML24183A0972024-07-12012 July 2024 ISFSI; Catawba 1, 2 & ISFSI; McGuire 1, 2 & ISFSI; Oconee 1, 2, 3 & ISFSI; Shearon Harris 1; H. B. Robinson 2 & ISFSI; and Radioactive Package Shipping Under 10 CFR 71 (71-266 & 71-345) – Review of QA Program Changes EPID L-2024-LLQ-0002 IR 05000324/20244202024-07-0202 July 2024 – Security Baseline Inspection Report 05000324/2024420 and 05000325/2024420 ML24108A0702024-06-0505 June 2024 – Issuance of License Amendments to Revise the 10 CFR 50.69 Categorization Process to Reflect an Alternative Seismic Approach IR 05000324/20244022024-05-17017 May 2024 Plan Material Control and Accounting Program Inspection Report 05000324/2024402 and 05000325/2024402 - Cover Letter IR 05000324/20240012024-05-0909 May 2024 Integrated Inspection Report 05000324/2024001 and 05000325/2024001 05000325/LER-2024-002, Re Automatic Start of Emergency Diesel Generator Due to Emergency Bus De-energization2024-04-10010 April 2024 Re Automatic Start of Emergency Diesel Generator Due to Emergency Bus De-energization 05000325/LER-2024-001, Primary Containment Penetration Local Leak Rate Testing Failure2024-04-10010 April 2024 Primary Containment Penetration Local Leak Rate Testing Failure ML24066A0132024-03-0505 March 2024 Bru 2024-002 Radiation Safety Baseline Inspection Information Request ML24026A0982024-03-0101 March 2024 Exemption from Select Requirements of 10 CFR Part 73 (EPID L-2023-LLE-0057 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting)) IR 05000324/20230062024-02-28028 February 2024 Annual Assessment Letter for Brunswick Steam Electric Plant, Units 1 and 2 – NRC Inspection Reports 05000324/2023006 and 05000325/2023006 IR 05000324/20244032024-02-14014 February 2024 Information Request for the Cybersecurity Baseline Inspection, Notification to Perm Inspection 05000325/2024403; 05000324/2024403 ML24032A1392024-02-12012 February 2024 Correction of Errors within Authorized Alternative Request RA-22-0308 IR 05000324/20230042024-02-0606 February 2024 Integrated Inspection Report 05000324/2023004 and 05000325/2023004 IR 05000324/20230112023-12-26026 December 2023 NRC Fire Protection Team Inspection - FPTI Report 05000324/2023011 and 05000325/2023011 IR 05000324/20234022023-12-14014 December 2023 Security Baseline Inspection Report 05000324-2023402 and 05000325-2023402 ML23297A0262023-11-27027 November 2023 – Proposed Alternatives to ASME Code Section XI Subsection IWE Requirements for Torus Metallic Liner Inspections ML23317A3462023-11-14014 November 2023 Duke Fleet - Correction Letter to License Amendment Nos. 312 & 340 Issuance of Amendments Regarding the Adoption of Technical Specifications Task Force Traveler TSTF-554, Revision 1 IR 05000324/20230032023-11-0101 November 2023 Integrated Inspection Report 05000324/2023003 and 05000325/2023003 IR 05000324/20230102023-10-17017 October 2023 Biennial Problem Identification and Resolution Inspection Report 05000324/2023010 and 05000325/2023010 IR 05000325/20234012023-10-16016 October 2023 Security Baseline Inspection Report 05000324 and 05000325 2023401 ML23346A1322023-10-0606 October 2023 Communication from C-10 Research & Education Foundation Regarding NextEra Common Emergency Fleet Plan License Amendment Request and Related Documents Subsequently Published ML23256A0882023-09-25025 September 2023 Issuance of Alternative to Steam Generator Welds ML23195A0782023-08-29029 August 2023 Issuance of Amendments Regarding the Adoption of Technical Specifications Task Force Traveler TSTF-554, Revision 1 IR 05000324/20230052023-08-23023 August 2023 Updated Inspection Plan for Brunswick Steam Electric Plant, Units 1 and 2 (Report 05000324/2023005 and 05000325/2023005) IR 05000324/20230022023-08-0404 August 2023 Integrated Inspection Report 05000324/2023002 and 05000325/2023002 ML23201A2042023-07-28028 July 2023 Summary of Regulatory Audit in Support of Alternative Request RA-22-0308 for Inservice Inspection of the Torus Metallic Liner IR 05000324/20243012023-07-25025 July 2023 – Notification of Licensed Operator Initial Examination 05000325/2024301 and 05000324/2024301 05000324/LER-2023-001, Two Main Steam Line Safety Relief Valves Inoperable2023-07-17017 July 2023 Two Main Steam Line Safety Relief Valves Inoperable 05000325/LER-2023-001, Loss of Redundant Power Supply Operation Causes Turbine Trip and Subsequent Reactor Scram2023-06-15015 June 2023 Loss of Redundant Power Supply Operation Causes Turbine Trip and Subsequent Reactor Scram ML23146A0012023-05-24024 May 2023 EN 56538 - Engine Systems Inc and Brunswick ML23212A9502023-05-24024 May 2023 Engine Systems, Inc., Part 21 Report Re Woodward EGB-35P Governor/Actuator with Foreign Material ML23130A3902023-05-12012 May 2023 – Regulatory Audit Plan in Support of Alternative Request RA 22-0308 for Inservice Inspection of the Torus Metallic Liner IR 05000324/20230012023-05-10010 May 2023 – Integrated Inspection Report 05000324 2023001 and 05000325 2023001 ML23118A0762023-05-0101 May 2023 Approval for Use of Specific Provision of a Later Edition of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section XI IR 05000324/20220042023-04-0404 April 2023 Reissue - Brunswick Steam Electric Plant - Integrated Inspection Report 05000324/2022004 and 05000325/022004 ML22332A4932023-03-10010 March 2023 William States Lee III 1 and 2 - Issuance of Amendments Regarding the Relocation of the Emergency Operations Facility IR 05000324/20220062023-03-0101 March 2023 Annual Assessment Letter for Brunswick Steam Electric Plant, Units 1 and 2 – NRC Inspection Reports 05000324/2022006 and 05000325/2022006 ML23033A5252023-02-0808 February 2023 Integrated Inspection Report 05000324/2022004 and 05000325/2022004 IR 05000324/20223012023-02-0303 February 2023 NRC Operator License Examination Report 05000325/2022301 and 05000324/2022301 IR 05000324/20224022022-11-23023 November 2022 Security Baseline Inspection Report 05000324 2022402 and 05000325 2022402 ML22332A0132022-11-23023 November 2022 Operator Licensing Written Examination Approval 05000325/2022301 and 05000324/2022301 ML22096A0032022-11-18018 November 2022 McGuire Nuclear Station and Shearon Harris Nuclear Power Plant Authorization of RA-19-0352 Regarding Use of Alternative for RPV Head Closure Stud Examinations 2024-09-04
[Table view] Category:License-Operator Examination Report
MONTHYEARIR 05000324/20203012021-01-22022 January 2021 NRC Operator License Examination Report 05000325/2020301 and 05000324/2020301 IR 05000324/20193012019-03-0404 March 2019 NRC Operator License Examination Report 05000325/2019301 and 05000324/2019301 ML17277A3302017-10-0303 October 2017 NRC Examination Report 05000325/2017301 and 05000324/2017301 IR 05000324/20163012017-01-27027 January 2017 NRC Examination Report 05000325/2016301 and 05000324/2016301 IR 05000324/20153012016-02-19019 February 2016 NRC Examination Report 05000325/2015301 and 05000324/2015301, December 17, 2015 and December 15, 2015 IR 05000324/20143012014-11-19019 November 2014 Er 05000325/2014301 and Er 05000324/2014301; Operating Test October 6 - 14, 2014, & Written Exam October 21, 2014; Brunswick Steam Electric Plant, Units 1 & 2; Operator License Examinations IR 05000324/20123012013-01-23023 January 2013 Er 05000325/12-301 & 05000324/12-301, on 12/03-13/20123, Brunswick Steam Electric Plant - NRC Examination Report IR 05000324/20103022011-02-0101 February 2011 Er 05000325-10-302 and Er 05000324-10-302; on December 6-13, 2010, and December 20, 2010; Brunswick Steam Electric Plant, Units 1 & 2; Licensed Operator Examinations IR 05000324/20083022008-08-0505 August 2008 Er 05000325-08-302 and 05000324-08-302, on 08/04/2008, 10/06/2008, and 11/10/2008, Brunswick Steam Electric Plant - Reactor and Senior Reactor Operator Initial ML0821802362008-08-0505 August 2008 Er 05000325-08-302 and 05000324-08-302, on 08/04/2008, 10/06/2008, and 11/10/2008, Brunswick Steam Electric Plant - Reactor and Senior Reactor Operator Initial IR 05000324/20083012008-05-29029 May 2008 on 04/17/08 Examination Report 05000325/08-301 and 05000324/08-301, Reactor and Senior Reactor Operator Retake Initial IR 05000324/20073012007-09-12012 September 2007 Er 05000325-07-301, Er 05000324-07-301; 7/16 - 22/2007 and 08/3/2007; Brunswick Steam Electric Plant, Units 1 & 2; Licensed Operator Examinations ML0725600022007-09-12012 September 2007 Er 05000325-07-301, Er 05000324-07-301; 7/16 - 22/2007 and 08/3/2007; Brunswick Steam Electric Plant, Units 1 & 2; Licensed Operator Examinations BSEP-05-0120, Operator Licensing Examination Data2005-09-22022 September 2005 Operator Licensing Examination Data ML0435200362004-12-16016 December 2004 NRC Examination Report 05000325-04-301 and 05000324-04-301 2021-01-22
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION
REGION II
May 29, 2008
SUBJECT:
BRUNSWICK STEAM ELECTRIC PLANT - REACTOR AND SENIOR REACTOR OPERATOR RETAKE INITIAL EXAMINATIONS 05000325/2008301 AND 05000324/2008301
Dear Mr. Waldrep:
On April 17, 2008, the Nuclear Regulatory Commission (NRC) administered operating retake examinations to two Senior Reactor Operator (SRO) applicants of your company who had reapplied for licenses to operate the Brunswick Steam Electric Plant, Units 1 & 2. The NRC waived the written examinations since the individuals passed that portion of the test during the initial examination. On April 17, 2008, members of your staff administered an NRC Reactor Operator (RO) written retake examination to three employees of your company who had reapplied for a license to operate the Brunswick Steam Electric Plant, Units 1 & 2. The NRC waived the operating examination since the three individuals passed that portion of the test during the initial examination. At the conclusion of the examination, the examiners discussed the examination questions and preliminary findings with those members of your staff identified in the enclosed report.
The two SRO applicants passed the operating retake test and the three RO applicants passed the written examination. There were no post examination comments.
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and its enclosures will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS.) ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room.)
Should you have any questions concerning this letter, please contact me at (404) 562-4550.
Sincerely,
/RA/
Malcolm T. Widmann, Chief Operations Branch Division of Reactor Safety Docket Nos. 50-325, 50-324 License Nos. DPR-71, DPR-62
Enclosures:
1. Report Details
_________________________
OFFICE RII:DRS RII:DRS RII:DRP SIGNATURE /RA/ /RA/ /RA/
NAME Edwin Lea Malcolm Widmann Randy Musser DATE 05/28/2008 05/29/2008 05/28/2008 6/ /2008 6/ /2008 6/ /2008 6/ /2008 E-MAIL COPY? YES NO YES NO YES NO YES NO YES NO YES NO YES N
CP&L 2
REGION II==
Docket Nos.: 50-325, 50-324 License Nos.: DPR-71, DPR-62 Report Nos.: 05000325/2007301, 05000324/2007301 Licensee: Carolina Power and Light (CP&L)
Facility: Brunswick Steam Electric Plant, Units 1 & 2 Location: 8470 River Road SE Southport, NC 28461 Date: April 17, 2008 Examiner: E. Lea, Chief, Senior Operations Examiner Approved by: Malcolm T. Widmann, Chief Operations Branch Division of Reactor Safety Enclosure 1
SUMMARY OF FINDINGS ER 05000325/2008301, ER 05000324/2008301; April 17, 2008; Brunswick Steam Electric Plant, Units 1 & 2; Licensed Operator Examinations.
The Brunswick training staff developed the retake written examination and retake operating test.
This included all outlines, the written examination and job performance measures (JPMs). The NRC examiners conducted operator licensing retake initial examinations in accordance with the guidance of NUREG-1021, Revision 9, Supplement 1, Operator Licensing Examination Standards for Power Reactors. This examination implemented the operator licensing requirements identified in 10 CFR §55.41, §55.43, and §55.45.
The NRC administered the operating test on April 17, 2008. The Brunswick training staff administered the written examination on April 17, 2008. Two Senior Reactor Operator applicants passed the operating retake test and three Reactor Operator applicants passed the written retake examination. Based on successful completion of the retake examinations, all of the applicants were issued operator licenses commensurate with the level of examination administered.
There were no post examination comments.
No findings of significance were identified.
Enclosure 1
Report Details 4. OTHER ACTIVITIES 4OA5 Operator Licensing Initial Examinations a. Inspection Scope The licensee developed the operating test and written examination. The NRC reviewed the proposed examination to determine whether it was developed in accordance with NUREG-1021, Operator Licensing Examination Standards for Power Reactors, Revision 9, Supplement 1. Examination changes agreed upon between the NRC and the licensee were made according to NUREG-1021 and incorporated into the final version of the examination materials.
The examiner reviewed the licensees examination security measures while preparing and administering the examinations to ensure examination security and integrity complied with 10 CFR 55.49, Integrity of examinations and tests.
The examiner evaluated two Senior Reactor Operator (SRO) upgrade retake applicants who were being assessed under the guidelines specified in NUREG-1021. The examiner administered the operating tests on April 17, 2008. Members of the Brunswick Steam Electric Plant training staff administered the written examination to three Reactor Operator (RO) retake applicants on April 17, 2008. The evaluations of the applicants and review of documentation were performed to determine if the applicants, who applied for licensees to operate the Brunswick Steam Electric Plant, met requirements specified in 10 CFR Part 55.
b. Findings No findings of significance were identified.
Two SRO applicants passed the operating retake test and three RO applicants passed the written retake examination. There were no post examination comments concerning the examination. The written examinations, question references and answers may be accessed in the ADAMS system (ADAMS Accession Number ML081220301.)
Copies of all individual examination reports were sent to the facility Training Manager for evaluation and determination of appropriate remedial training.
Enclosure 1
4OA6 Meetings Exit Meeting Summary On April 17, 2008, the examiner discussed generic issues with you and members of your staff. The examiners asked the licensee whether any materials examined during the inspection should be considered proprietary. No proprietary information was identified.
PARTIAL LIST OF PERSONS CONTACTED E. Wills, Plant General Manager L. Beller, Supt Operations Training K. Bowdon, Senior Training Instructor B. Murray, Licensing T. Pearson, Initial Training Supervisor D. Griffith, Training Manager