IPaul Kaufman - A ing Management Proqram for Feedwater Nozzlesi -Opertn Experec a

1 From:

Paul Kaufman To:

TLO1 @nrc.gov Date:

11/15/2006 1:52:37 PM

Subject:

Aging Management Program for Feedwater Nozzles -Operating Experience

Tim, I just wanted to let you know that I reviewed the Oyster Creek aging management program for Feedwater Nozzles and found that AmerGen's operating experience review went back to 1977. I've attached a portion of AmerGen's AMP for Feewater Nozzles FYI.

I:DCM-pkLCL-tep5GIOO TPPg Lq:\\D0CUME-1\\ dk\\L0CALS-1\\temp\\5\\GM,00001.TMP 41 -, i 1 11 Page 111 Mail Envelope Properties (455B361F5.D59 :13 :57318)

Subject:

Aging Management Program for Feedwater Nozzles -Operating Experience Creation Date 11/15/2006 1:52:37 PM From:

Paul Kaufman Created By:

pdk@nrc.gov Recipients Action Date & Time nrc.gov kpl~po.KPDO Delivered 11/15/2006 1:5 PM PDK BC (Paul Kaufman)

Deleted 11/15/2006 1:5 PM Emptied 11/23/2006 1:1 AM TLO1I (Timothy O'Hara)

Opened 11/15/2006 3:0 PM Replied 11/15/2006 3:0 PM Post Office Delivered Route kpl~po.KP-DO 11/15/2006 1:52:38 PM nrc.gov Files Size Date & Time MESSAGE 256 11/15/2006 1:52:37 PM OC License Renewal AMP Feddwater Nozzles Oper Exper.wpd 8435 11/15/21 1:52:36 PM Options Auto Delete:

No Expiration Date:

None Notify Recipients:

Yes Priority:

Standard ReplyRequested:

No Return Notification:

Send Mail Receipt when Undeliverable Concealed

Subject:

No Security:

Standard To Be Delivered:

Immediate Status Tracking:

All Information 2:38 4:18 0:30 5:32 8:18 006

/

Oyster Creek PBD-AMP-B.1.05, Revision 0 License Renewal Project Pagel1 of 16 BWR Feedwater Nozzle Oyster Creek BWR Feedwater Nozzle 2.10 Operating Experience NUREG-1801: Cracking has occurred in several BWR plants (NUREG-0619, NRC Generic Letter 81 -11). This AMP has been implemented for nearly 25 years and has been found to be effective in managing the effect of cracking on the intended function of feedwater nozzles.

Oyster Creek: Operating experience, both internal and external, is used in two ways at Oyster Creek to enhance plant programs, prevent repeat events, and prevent events that have occurred at other plants from occurring at Oyster Creek. The first way in which operating experience is used is through the Oyster Creek Operating Experience process.

The Operating Experience process screens, evaluates, and acts on operating experience documents and information to prevent or mitigate the consequences of similar events.

The second way is through the process for managing programs. This process requires the review of program related operating experience by the program owner.

Both of these processes review operating experience from both external and internal (also referred to as in-house) sources. External operating experience may include such things as INPO documents (e.g., SOERs, SERs, SENs, etc.), NRC documents (e.g., GLs, LERs, INs, etc.), General Electric documents (e.g., RCSILs, SILs, TILs, etc.), and other documents (e.g., 10CFR Part 21 Reports, NERs, etc.). Internal operating experience may include such things as event investigations, trending reports, and lessons learned from in-house events as captured in program notebooks, self-assessments, and in the 10 CFR Part 50, Appendix B corrective action process.

BWR Feedwater Nozzle inspections have been implemented through the station ISI program plan, which incorporates the requirements of the ASME Code. Augmented inspections were performed in accordance with NUREG-0619, BWR Feedwater Nozzle and Control Rod Return Line Nozzle as modified in accordance with reference 4.3.3.

Demonstration that the effects of aging are effectively managed is achieved through objective evidence that shows that cracking is being adequately managed in feedwater nozzles. The following examples of operating experience provide objective evidence that the BWR Feedwater Nozzle aging management program is effective in assuring that intended function(s) will be maintained consistent with the CLB for the period of extended operation.

Oyste Crek inpete th.edwtrnoze!n 19771 inrsponsý"O:in (usty exeren.

Cakweefudiflntenoze and repard hT iimize teral

-y5lijng and ftgeiduced crackin'g", th'e' th"e'rmal sleeves§"ý we~re m"ýn'odified wt) itn yedeign.ý. Subsequent nsections, the -most recent i~n 2000, haefon0n i ndicationis in the. feewaiter nozzles-.,This p-rovidesobeie evidece that,'the modificaion haebe fetv nmtgtn h

ffects ofq thera

____he As outlined in Reference 4.2.2, Since 1980 significant field experience without the presence of additional fatigue cracking in feedwater and CRID return line nozzles has been accumulated. The operating experience at Oyster Creek is consistent with the experience throughout the industry. For xgreater than 25.years,theOiyster,Cre~ek BWR-_

~~edwater, Nozzle aing,manapgement. progr~a"'m has, been efciei aaigteefc of cackig on hthjintenejunt oo Ied nozzlrsp The BWR Feedwater Nozzle aging management activities will provide timely detection of aging degradation prior to loss of system or component functions for the period of extended operation.