P.O. Box 63 Lycoming, NY 13093 Constellation Energy Nine Mile Point Nuclear Station April 28, 2004 NMP2L 2116 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555
SUBJECT:
Nine Mile Point Unit 2 Docket No. 50-410 License No. NPF-69 Cycle 10 Core Operating Limits Report, Rev. 0 Gentlemen:
Attached is a copy of the Cycle 10 Core Operating Limits Report (COLR), Rev. 0, for Nine Mile Point Unit 2 (NMP2). This report is being submitted pursuant to NMP2 Technical Specification 5.6.5.d.
Very truly yours, William C. Holston Manager Engineering Services WCH/RF/bjh Attachment cc:
Mr. H. J. Miller, NRC Regional Administrator, Region I Mr. G. K Hunegs, NRC Senior Resident Inspector Mr. P. S. Tam, Senior Project Manager, NRR (2 copies)
NI7VE MILE POINT UNIT 2 CORE OPERATING LIMITS REPORT Document No.:
COLR2-10 Revision 0, Cycle 10 Name Title Date Prepared by:
Reviewed by:
C W. Lepin J
Wink
.- 31kslby Fuel Engineer
.a-3/26/d1y Fuel Engineer Independently reviewed by:
Approved by:
Fuel Engineer Principal Engineer, Nuclear Fuels Services 0,
ff/-O//
Me A. Annenta Approved by:
Approved by:
ff7-D.
J. N. Darweesh G. &a~vis Supervisor, Reactor Engineering W A/aO/
1I Director, Nuclear Fuels Services This Controlled Document provides cycle specific core operating limits for use in conjunction with the Nine Mile Point Unit X
.chnical Specifications. Document pages may only be changed through a reissue of the entire document.
Revision 0 Cycle 10 NINE MILE POINT UNIT 2 CORE OPERATING LIMITS REPORT Table of Contents Page 1.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (A]PLHGR)...................
1 1.1 Limits for Technical Specification 3.2.1 1
2.0 MlINIMUM CRITICAL POWER RATIO (ODYN OPTION B).................................... 16 2.1 Limits for Technical Specification 3.2.2
...... 16 3.0 LINEAR HEAT GENERATION RATE (LHGR) 22 3.1 Limits for Technical Specifications 3.2.3
.................................................... 22 4.0 AVERAGE PO'¶ER RANGE MONITOR SETPOINWS
... 24 4.1 Limits for Technical Specification Table 3.3.1.1-1 (OPRM Upscale)................... 24 5.0 ROD BLOCK MONITOR (R1BM)...........
25 5.1 Allowable Value for Technical Specification Table 3.3.2.1-1.
25 6.0 RE2REF NCES FOR TECHNICAL SPECIFICATIONS.........
26
7.0 REFERENCES
FOR TECHNICAL SPECIFICATION BASES
................................. 27 8.0 SOURCE DOCUMENS...................
28 Page i
'i 4;S Revision 0 Cycle 10 NINE MILE POINT UNIT 2 CORE OPERATING LIMITS REPORT 1.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR' 1.1 Limits for Technical Specification 3.2.1 The APLHGR(s) for each type of fuel as a function of AVERAGE PLANAR EXPOSURE shall not exceed the limits shown in Tables la through 11.
The limits of Tables la through In shall be reduced to a value of.78 times the two recirculation loop operation limit when in single recirculation loop operation.
NO When hand calculations are required, the APLHGR as a function of average planar exposure shall not exceed the respective limits shown in Tables im and ln during two recirculation loop operation.
Page 1 of 29
"1NE MILE POINT UNIT 2 COLR2-10, Revision 0 Cycle 10 Table la MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GE11-P9CUB413-12GZ-12OT-146-T (GEII)
Average Planar Exposure, MAPLHGR Limits (kwlft)
GWd/ST Lattice Lattice Lattice Lattice 2275 2545 2549 2274 0.00 12.78 11.43 11.45 13.38 0.20 12.72 11.46 11.49 13.35 1.00 12.55 11.53 11.57 13.26 2.00 12.49 11.61 11.68 13.23 3.00 12.49 11.69 11.78 13.24 4.00 12.52 11.77 11.89 13.27 5.00 12.55 11.86 12.01 13.29 6.00 12.58 11.94 12.12 13.32 7.00 12.60 12.03 12.24 13.34 8.00 12.63 12.11 12.36 13.35 9.00 12.64 12.20 12.48 13.36 10.00 12.65 12.29 12.60 13.37 12.50 12.51 12.26 12.65 13.33 15.00 12.12 12.11 12.44 12.94 17.50 11.72 11.90 12.13 12.54 20.00 11.33 11.61 11.80 12.15 25.00 10.62 11.08 11.09 11.36 30.00 10.13 10.75 10.44 10.88 35.00 9.65 10.29 9.96 10.40 40.00 9.18 9.82 9.52 9.93 45.00 8.71 9.40 9.14 9.46 50.00 8.24 8.99 8.80 9.00 54.96 7.78 55.00 8.62 8.48 8.53 58.06 8.41 58.32 8.22 58.66 8.30 NOTE: A "-J indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point in each column. MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.
Page 2 of 29
-NINE MILE POINT UNIT 2 COLR2-10, Revision 0 Cycle 10 Table lb MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GE11-P9CUB414-13GZ-120T-146-T (GEll)
Average Planar Esposure, MAPLHGR Limits (kwlft_
GWdtST Lattice Lattice Lattice Lattice Lattice 2275 2545 2546 2547 2548 0.00 12.78 11.43 11.25 11.41 13.42 0.20 12.72 11.46 11.30 11.45 13.39 1.00 12.55 11.53 11.39 11.52 13.30 2.00 12.49 11.61 11.50 11.61 13.27 3.00 12.49 11.69 11.62 11.71 13.28 4.00 12.52 11.77 11.74 11.80 13.30 5.00 12.55 11.86 11.87 11.90 13.33 6.00 12.58 11.94 11.99 12.01 13.35 7.00 12.60 12.03 12.10 12.11 13.37 8.00 12.63 12.11 12.21 12.22 13.38 9.00 12.64 12.20 12.32 12.33 13.39 10.00 12.65 12.29 12.44 12.44 13.40 12.50 12.51 12.26 12.48 12.49 13.36 15.00 12.12 12.11 12.36 12.36 12.97 17.50 11.72 11.90 12.11 12.12 12.57 20.00 11.33 11.61 11.79 11.80 12.17 25.00 10.62 11.02 11.08 11.08 11.39 30.00 10.13 10.55 10.43 10.43 10.90 35.00 9.65 10.09 9.95 9.96 10.43 40.00 9.18 9.63 9.52 9.52 9.95 45.00 8.71 9.17 9.13 9.14 9.49 50.00 8.24 8.72 8.79 8.79 9.02 54.96 7.78 55.00 8.27 8.47 8.44 8.55 57.19 8.08 58.28 8.17 58.42 8.23 58.58 8.30 NOTE: A "-"
idicates that there is no entry or this box and the limit can be dete Iined by lnearly interpolating between the previous and next point in each column. MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximumn allowed nodal exposure for that lattice.
Page 3 of 29
'NINE MILE POINT UNIT 2 COLR2-10, Revision 0 Cycle 10 Table Ic MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GE11-P9CUB407-14GZ-120T-146-T-2382 (GEll)
Average Planar Exposure, IMAPLHGR Limits (kw/ft)
GWd/ST Lattice Lattice Lattice Lattice Lattice 2887 2888 2889 2890 2891 0.00 12.76 10.97 11.19 11.10 13.38 0.20 12.69 11.02 11.23 11.14 13.35 1.00 12.52 11.10 11.30 11.23 13.26 2.00 12.46 11.19 11.39 11.33 13.23 3.00 12.46 11.29 11.48 11.44 13.24 4.00 12.49 11.38 11.57 11.54 13.27 5.00 12.52 11.48 11.66 11.64 13.29 6.00 12.55 11.58 11.75 11.75 13.32 7.00 12.58 11.69 11.84 11.86 13.34 8.00 12.60 11.79 11.93 11.97 13.36 9.00 12.62 11.90 12.03 12.09 13.37 10.00 12.63 12.00 12.13 12.21 13.37 12.50 12.48 11.96 12.10 12.25 13.33 15.00 12.09 11.84 11.98 12.17 12.94 17.50 11.70 11.71 11.80 11.96 12.54 20.00 11.30 11.49 11.52 11.65 12.14 25.00 10.59 11.01 11.01 11.10 11.36 30.00 10.10 10.68 10.68 10.54 10.87 35.00 9.62 10.35 10.36 10.07 10.40 40.00 9.15 9.89 9.92 9.63 9.93 45.00 8.68 9.46 9.49 9.24 9.46 50.00 8.21 9.07 9.07 8.87 8.99 54.80 7.77 55.00 8.66 8.67 8.53 8.52 57.55 8.48 57.64 8.48 57.97 8.36 58.26 8.22 NT:
A "-ndicates thatihee is no entry othis box and re limit can be Uitsmre by hnea interpolating between the previous and next point in each column. MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.
Page 4 of 29
NINE MIELE POINT UNIT 2 COLR2-10, Revision 0 Cycle 10 Table ld MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GE11-P9CUB407-14GZ-i20T-146-T-2383 (GE11)
Average Planar Exposure,
_MAPLHGR Limits (kwlft)
GWdJST Lattice Lattice Lattice Lattice Lattice 2887 2888 2892 2893 2891 0.00 12.76 10.97 11.03 10.93 13.38 0.20 12.69 11.02 11.08 10.98 13.35 1.00 12.52 11.10 11.17 11.08 13.26 2.00 12.46 11.19 11.28 11.21 13.23 3.00 12.46 11.29 11.40 11.35 13.24 4.00 12.49 11.38 11.51 11.49 13.27 5.00 12.52 11.48 11.63 11.62 13.29 6.00 12.55 11.58 11.74 11.74 13.32 7.00 12.58 11.69 11.84 11.86 13.34 8.00 12.60 11.79 11.94 11.98 13.36' 9.00 12.62 11.90 12.03 12.10 13.37 10.00 12.63 12.00 12.13 12.22 13.37 12.50 12.48 11.96 12.10 12.26 13.33 15.00 12.09 11.84 11.98 12.17 12.94 17.50 11.70 11.71 11.79 11.95 12.54 20.00 11.30 11.49 11.51 11.65 12.14 25.00 10.59 11.01 11.01 11.10 11.36 30.00 10.10 10.68 10.68 10.54 10.87 35.00 9.62 10.35 10.36 10.07 10.40 40.00 9.15 9.89 9.92 9.63 9.93 45.00 8.68 9.46 9.49 9.24 9.46 50.00 8.21 9.07 9.07 8.87 8.99 54.80 7.77 55.00 8.66 8.67 8.52 8.52 57.55 8.48 57.62 B.48 57.96 8.36 58.26 1
_8.22 A
indicates that is no entry or this box and tle limit can be dc ie by linearly interpolating between the previous and next point in each column. MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.
Page 5 of 29
I,-NINE MILE POINT UNIT 2 COLR2-10, Revision 0 Cycle 10 Table le MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GE11-P9CUB404-12GZ-12OT-146-T-2501 (GEll)
Average Planar Exposure, MAPLHGR Limits (kw/ft)
GWd/ST Lattice Lattice Lattice Lattice Lattice 5230 5231 5232 5233 5234 0.00 12.76 11.12 11.14 10.93 13.36 0.20 12.69 11.17 11.19 11.00 13.33 1.00 12.52 11.26 11.29 11.13 13.24 2.00 12.46 11.39 11.42 11.32 13.21 3.00 12.46 11.54 11.57 11.53 13.22 4.00 12.49 11.66 11.69 11.74 13.25 5.00 12.52 11.73 11.77 11.87 13.27 6.00 12.55 11.80 11.85 11.98 13.30 7.00 12.58 11.88 11.93 12.09 13.32 8.00 12.60 11.96 12.02 12.19 13.34 9.00 12.62 12.04 12.10 12.29 13.35 10.00 12.63 12.12 12.18 12.40 13.36 12.50 12.48 12.05 12.14 12.44 13.31 15.00 12.09 11.89 11.98 12.24 12.92 17.50 11.70 11.73 11.77 11.94 12.53 20.00 11.30 11.47 11.48 11.61 12.13 25.00 10.59 10.97 10.97 11.05 11.35 30.00 10.10 10.64 10.64 10.70 10.86 35.00 9.62 10.32 10.32 10.17 10.39 40.00 9.15 9.95 9.98 9.70 9.92 45.00 8.68 9.48 9.50 9.27 9.45 50.00 8.21 9.05 9.07 8.88 8.98 54.80 7.77 55.00 8.66 8.67 8.52 8.51 57.53 8.52 57.56 8.52 57.87 8.36-58.22 8.21 NOTE: A -'
indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point in each column. MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.
Page 6 of 29
NINE MILE POINT UNIT 2 COLT
- Table lf MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GElI-P9CUB407-14G Z120T-146-T-2502 (GEll)
U2-10, Revision 0 Cycle 10 Average Planar Exposure, MAPLHGR Limits (kwlft)
GWdlST Lattice Lattice Lattice Lattice Lattice 5230 5235 5236 5237 5238 0.00 12.76 10.98 11.19 11.10 13.38 0.20 12.69 11.03 11.23 11.15 13.35 1.00 12.52 11.10-11.30 11.23 13.26 2.00 12.46 11.19 11.39 11.33 13.23 3.00 12.46 11.29 11.48 11.44 13.24
.4.00 12.49 11.38 11.57 11.54 13.27 5.00 12.52 11.48 11.66 11.64 13.29 6.00 12.55 11.58 11.75 11.75 13.32 7.00 12.58 11.68 11.84 11.86 13.34 8.00 12.60 11.79 11.93 11.97 13.36 9.00 12.62 11.89 12.03 12.09 13.37 10.00 12.63 12.00 12.12 12.21 13.37 12.50 12.48 11.96 12.10 12.25 13.33 15.00 12.09 11.83 11.97 12.16 12.94 17.50 11.70 11.71 11.79 11.95 12.54 20.00 11.30 11.49 11.51 11.65 12.14 25.00 10.59 11.01 11.00 11.10 11.36 30.00 10.10 10.68 10.68 10.54 10.87 35.00 9.62 10.36 10.35 10.07 10.40 40.00 9.15 9.89 9.93 9.63 9.93 45.00 8.68 9.46 9.49 9.24 9.46 50.00 8.21 9.07 9.07 8.87 8.99 54.80 7.77 55.00 8.66 8.67 8.53 8.52 57.53 8.48 57.63 8.48 57.96 8.36 58.26
-=
8.22 NOTE: A "-" indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point in each column. MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.
Page 7 of 29
P
`0NINE MILE POINT UNIT 2 COLR2-10, Revision 0 Cycle 10 Table lg MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GEl 1-P9CUB407-14GZ-120T-146-T-2503 (GEl 1)
Average Planar Exposure, MAPLHGR Limits (kw/ft)
GWdlST Lattice Lattice Lattice Lattice Lattice 5230 5235 5239 5240 5238 0.00 12.76 10.98 11.04 10.93 13.38 0.20 12.69 11.03 11.08 10.99 13.35 1.00 12.52 11.10 11.17 11.08 13.26 2.00 12.46 11.19 11.28 11.21 13.23 3.00 12.46 11.29 11.40 11.35 13.24 4.00 12.49 11.38 11.51 11.48 13.27 5.00 12.52 11.48 11.63 11.62 13.29 6.00 12.55 11.58 11.74 11.74 13.32 7.00 12.58 11.68 11.84 11.86 13.34 8.00 12.60 11.79 11.93 11.98 13.36 9.00 12.62 11.89 12.03 12.09 13.37 10.00 12.63 12.00 12.13 12.22 13.37 12.50 12.48 11.96 12.10 12.25 13.33 15.00 12.09 11.83 11.97 12.16 12.94 17.50 11.70 11.71 11.79 11.95 12.54 20.00 11.30 11.49 11.51 11.65 12.14 25.00 10.59 11.01 11.00 11.10
.__11.36 30.00 10.10 10.68 10.68 10.54 10.87 35.00 9.62 10.36 10.35 10.07 10.40 40.00 9.15 9.89 9.93 9.64 9.93 45.00 8.68 9.46 9.49 9.24 9.46 50.00 8.21 9.07 9.07 8.87 8.99 54.80 7.77 55.00 8.66 8.67 8.53 8.52 57.53 8.48 57.61 8.48 57.95
-- 8.36 58.26 8.22 NOTE: A '-'
indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point in each column. MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.
Page 8 of 29
NINE MILE POINT UNIT 2 COLR2-10, Revision 0 Cycle 10 Table 1h MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GE14-PIOCNAB406-15GZ-120T-150-T-2674 (GE14C)
Average MAPLHGR Limits (kw/ft)
Planar Lattice Lattice Lattice Lattice Lattice Lattice Lattice
- Exposure, 6101 6102 6103 6104 6105 6106 6107 GWd/ST 0.00 11.42 9.75 10.05 10.07 9.97 11.82 12.11 0.20 11.33 9.82 10.11 10.12 10.03 11.77 12.08 1.00 11.10 9.92 10.19 10.22 10.12 11.61 11.97 2.00 11.01 10.04 10.29 10.35 10.26 11.56 11.95 3.00 11.00 10.16 10.39 10.46 10.41 11.57 11.96 4.00 11.02 10.28 10.50 10.58 10.56 11.60 11.99 5.00 11.04 10.40 10.60 10.70 10.73 11.63 12.02 6.00 11.07 10.53 10.70 10.83 10.86 11.67 12.05 7.00 11.09 10.66 10.81 10.96 10.99 11.69 12.08 8.00 11.11 10.79 10.91 11.09 11.13 11.72 12.10 9.00 11.13 10.93 11.02 11.22 11.25 11.73 12.11 10.00 11.14 11.07 11.13 11.36 11.35 11.75 12.12 11.00 11.15 11.20 11.25 11.49 11.45 11.76 12.12 12.00 11.14 11.25 11.30 11.57 11.53 11.76 12.12 13.00 11.02 11.26 11.27 11.54 11.51 11.70 12.11 14.00 10.89 11.23 11.23 11.50 11.48 11.58 11.98 14.51 10.83 11.20 11.20 11.47 11.46 11.51 11.92 15.00 10.76 11.18 11.18 11.44 11.43 11.45 11.85 17.00 10.50 11.06 11.07 11.30 11.30 11.19 11.58 19.13 10.22 10.89 10.91 11.11 11.12 10.90 11.30 20.00 10.11 10.82 10.84 11.04 11.04 10.79 11.18 25.00 9.46 10.36 10.38 10.55 10.56 10.13 10.52 30.00 8.81 9.88 9.90 10.06 10.07 9.48 9.87 35.00 8.17 9.40 9.42 9.58 9.60 8.84 9.23 40.00 7.53 8.91 8.93 9.09 9.11 8.20 8.60 45.00 6.90 8.40 8.42 8.58 8.60 7.57 7.97 50.00 5.13 7.86 7.87 8.04 8.06 6.84 7.34 51.90 4.15 54.81 4.36 55.00 5 5.98 5.94 6.41 6.44 5.27 56.52 4.49 57.19
_-4.85 57.28 4.84 4.8S
=
57.61 5.11 5.13 58.06 4.88 58.07 4.90 NOTE: A "-"
indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point in each column. MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.
Page 9 of 29
e CANINE MILE POINT UNIT 2 COLR2-10, Revision 0 Cycle 10 Table I i MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GE14-PIOCNAB4O4-45GZ-120T-160-T-2675 (GE14C)
Average MAPLHGR Limits (kwlft)
Planar Lattice Lattice Lattice Lattice Lattice Lattice Lattice
- Exposure, 6101 6108 6109 6110 6111 6106 6112 GWdIST 0.00 11.42 9.72 9.91 9.95 9.84 11.82 12.37 0.20 11.33 9.78 9.97 10.01 9.91 11.77 12.34 1.00 11.10 9.87 10.05 10.11 10.01 11.61 12.24 2.00 11.01 9.98 10.18 10.26 10.17 11.56 12.20 3.00 11.00 10.12 10.31 10.42 10.33 11.57 12.21 4.00 11.02 10.29 10.45 10.59 10.51 11.60 12.24 5.00 11.04 10.44 10.60 10.77 10.70 11.63 12.26 6.00 11.07 10.61 10.75 10.95 10.89 11.67 12.28 7.00 11.09 10.76 10.91 11.14 11.10 11.69 12.30 8.00 11.11 10.89 11.04 11.28 11.31 11.72 12.32 9.00 11.13 11.02 11.16 11.42 11.52 11.73 12.33 10.00 11.14 11.16 11.27 11.56 11.67 11.75 12.33 11.00 11.15 11.29 11.39 11.71 11.76 11.76 12.34 12.00 11.14 11.35 11.46 11.85 11.85 11.76 12.34 13.00 11.02 11.35 11.46 11.87 11.84 11.70 12.34 14.00 10.89 11.34 11.45 11.81 11.78 11.58 12.23 14.51 10.83 11.33 11.44 11.78 11.75 11.51 12.17 15.00 10.76 11.33 11.42 11.74 11.72 11.45 12.10 17.00 10.50 11.23 11.31 11.57 11.55 11.19 11.84 19.13 10.22 11.08 11.12 11.35 11.34 10.90 11.56 20.00 10.11 11.01 11.04 11.26 11.25 10.79 11.44 25.00 9.46 10.52 10.53 10.73 10.72 10.13 10.78 30.00 8.81 10.02 10.03 10.21 10.20 9.48 10.14 35.00 8.17 9.51 9.53 9.69 9.70 8.84 9.50 40.00 7.53 8.99 9.02 9.18 9.19 8.20 8.87 45.00 6.90 8.47 8.49 8.65 8.67 7.57 8.24 50.00 5.13 7.92 7.93 8.10 8.12 6.84 7.61 51.90 4.15 54.81 4.36 55.00 6.14 6.12 6.68 6.75 5.95 57.52 4.85
- 57.60 4.84 57.61 5.37 5.44 4.61 57.68 4.57 58.58 4.89 58.71 4.89 NOTE: A "-"
indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point in each column. MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.
Page 10 of 29
I WNINE MILE POINT UNIT 2 COLR2-10, Revision 0 Cycle 10 Table I1 MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GE14-Pl CNAB403-17GZ-120T-160-T-2676 (GE14C)
Average MALHGR Limits (kwlft)
Planar Lattice Lattice Lattice Lattice Lattice Lattice Lattice
- Exposure, 6101 6113 6114 6115 6116 6106 6117 GWdJST 0.00 11.42 9.60 9.76 9.67 9.52 11.82 12.29 0.20 11.33 9.67 9.81 9.76 9.62 11.77 12.26 1.00 11.10 9.76
-9.90 9.88 9.75 11.61 12.16 2.00 11.01 9.89 10.02 10.05 9.92 11.56 12.14 3.00 11.00 10.02 10.13 10.19 10.09 11.57 12.15 4.00 11.02 10.16 10.26 10.34 10.28 11.60 12.18 5.00 11.04 10.30 10.38 10.48 10.47 11.63 12.20 6.00 11.07 10.44 10.51 10.64 10.65 11.67 12.23 7.00 11.09 10.58 10.64 10.80 10.82 11.69 12.25 8.00 11.11 10.73 10.78 10.96 10.99 11.72 12.27 9.00 11.13 10.88 10.91 11.13 11.16 11.73 12.28 10.00 11.14 11.03 11.05 11.29 11.34 11.75 12.28 11.00 11.15 11.18 11.19 11.46 11.50 11.76 12.29 12.00 11.14 11.22 11.23 11.56 11.58 11.76 12.29 13.00 11.02 11.24 11.25 11.57 11.55 11.70 12.28 14.00 10.89 11.25 11.25 11.51 11.50 11.58 12.17 14.51 10.83 11.22 11.22 11.48 11.47 11.51 12.11 15.00 10.76 11.19 11.20 11.44 11.44 11.45 12.04 17.00 10.50 11.06 11.07 11.27 11.28 11.19 11.78 19.13 10.22 10.88 10.88 11.07 11.07 10.90 11.49 20.00 10.11 10.81 10.81 10.99 10.99 10.79 11.38 25.00 9.46 10.33 10.33 10.49 10.50 10.13 10.72 30.00 8.81 9.85 9.85 10.00 10.01 9.48 10.07 35.00 8.17
-9.37 9.37 9.52 9.54 8.84 9.43 40.00 7.53 8.88 8.88 9.03 9.05 8.20 8.80 45.00 6.90 8.37 8.37 8.53 8.55 7.57 8.17 50.00 5.13 7.83 7.84 7.99 8.02 6.84 7.54 51.90 4.15 54.81 4.36 55.00 5.88 5.91 6.38 6.40 5.78 57.11 4.83
- 57.15 4.83 57.39 4.55 57.61 5.07 5.10 58.04 4.86 4.-88 58.05 4.88 NOTE: A '-'
indicates that there is no entry for this box and the limit can be determined by -
linearly interpolating between the previous and next point in each column. MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.
Page 11 of 29
S INE MILE POINT UNIT 2 COLR2-10, Revision 0 Cycle 10 Table 1k MAPLHFGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GE11-P9CUB349-1OGZ1-120M-146-T (GEll)
Avenge Planar Exposure, MAPLHGR Limits (kw/ft)
GWdJST Lattice Lattice Lattice Lattice Lattice 1941 1942 1943 1944 1723 and 0.00 11.41 11.62 11.11 11.35 12.83 0.20 11.46 11.67 11.17 11.40 12.77 1.00 11.58 11.78 11.31 11.53 12.61 2.00 11.75 11.93 11.52 11.72 12.56 3.00 11.93 12.10 11.74 11.93 12.57 4.00 12.09 12.24 11.98 12.15 12.60 5.00 12.25 12.39 12.23 12.38 12.63 6.00 12.42 12.53 12.49 12.63 12.67 7.00 12.59 12.61 12.73 12.84 12.70 8.00 12.73 12.69 12.78 12.90 12.72 9.00 12.83 12.78 12.82 12.92 12.74 10.00 12.89 12.87 12.85 12.93 12.75 12.50 12.84 12.86 12.77 12.80 12.62 15.00 12.48 12.49 12.39 12.40 12.24 17.50 12.12 12.13 12.00 12.00 11.84 20.00 11.76 11.76 11.61 11.61 1.AS 25.00 11.03 11.03 10.84 10.84 10.66 30.00 10.31 10.31 10.10 10.10 9.88 35.00 9.59 9.60 9.40 9.41 9.11 40.00 8.89 8.90 8.75 8.75 8.34 45.00 8.20 8.21 8.12 8.13 7.58 50.00 7.51 7.51 7.51 7.52 6.82 55.00 6.81 6.81 6.89 6.90 6.06 55.45 5.99 57.39 6.58 57A5 6.59 57.66 6.43 57.71 6.43 NOTE: A 'S indicates that tere is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point in each colurmn MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.
Page 12 of 29
N-
- 4 IV NINE MILE POINT UNIT 2 COLR2-10, Revision 0 Cycle 10 "Table 11 MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GE11-P9CUB37S-12GZ-120T-146-T (GEll)
Average Planar Expqsure, MAPLHGR limits (Ikw/ft)
GWdIST Lattice Lattice Lattice Lattice Lattice Lattice 2275 2270 2271 2272 2273 2274 0.00 12.78 11.34 11.57 11.12 11.37 13.38 0.20 12.72 11.39 11.61 11.18 11.42 13.35 1.00 12.55 11.49 11.68 11.29 11.52 13.26 2.00 12A9 11.63 11.76 11.46 11.67 13.23 3.00 12.49 11.78 11.85 11.64 11.84 13.24 4.00 12.52 11.94 11.94 11.83 11.97 13.27 5.00 12.55 12.02 12.03 12.02 12.07.
13.29 6.00 12.58 12.11 12.12 12.13 12.17 13.32 7.00 12.60 12.20 12.21 12.24 12.27 13.34 8.00 12.63 12.30 12.31 12.36 12.38 13.35 9.00 12.64 12.39 12.41 12.48 12.49 13.36 10.00 12.65 12.49
.12.52 12.61 12.61 13.37 12.50 12.51 12.52 12.55 12.71 12.70 13.33 15.00 12.12 12.37 12.38 12.55 12.55 12.94 17.50 11.72 12.09 12.10 12.26 12.26 12.54 20.00 11.33 11.73 11.74 11.93 11.93 12.15 25.00 10.62 11.05 11.07 11.23 11.25 11.36 30.00 10.13 10.62 10.63 10.75 10.76 10.88 35.00 9.65 10.19 10.20 10.29 10.30 10.40 40.00 9.18 9.77 9.78 9.86 9.87 9.93 45.00 8.71 9.36 9.37 9.47 9.47 9.46 50.00 8.24 8.96 8.97 9.09 9.10 9.00 54.96 7.78 55.00 8.56 8.57 8.73 8.74 8.53 57.43 8.38 57.56 8.36 58.27 8.50 58.32 8.22 58.41 8.48 NOTE: A - indicates thatere is no cntsy for tins box n i
iheliriut can be detune by libearly inti spolFjtig between the previous and next point in each colmnn MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.
Page 13 of 29
b bNINE MILE POINT UNIT 2 COLR2-10, Revision 0 Cycle 10 Table Im MOST LMITING MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Average MAPLHGR Limits (kwlft) l Planar P9CUB413 P9CUB414 P9CUB407-P9CUB407-P9CUB404-P9CUJB407. P9CUB407-P9CUB37S
- Exposure, (GEll)
(GEll) 2382 2383 2501 2502 2503 (GElI)
GWd/ST (GEll)
(GEll)
(GEll)
(GEll)
(GElI) 0.00 11.43 11.25 10.97 10.93 10.93 10.98 10.93 11.12 0.20 11.46 11.30 11.02 10.98 11.00 11.03 10.99 11.18 1.00 11.53 11.39 11.10 11.08 11.13 11.10 11.08 11.29 2.00 11.61 11.50 11.19 11.19 11.32 11.19 11.19 11.46 3.00 11.69 11.62 11.29 11.29 11.53 11.29 11.29 11.64 4.00 11.77 11.74 11.38 11.38 11.66 11.38 11.38 11.83 5.00 11.86 11.86 11.48 11.48 11.73 11.48 11.48 12.02 6.00 11.94 11.94 11.58 11.58 11.80 11.58 11.58 12.11 7.00 12.03 12.03 11.69 11.69 11.88 11.68 11.68 12.20 8.00 12.11 12.11 11.79 11.79 11.96 11.79 11.79 12.30 9.00 12.20 12.20 11.90 11.90 12.04 11.89 11.89 12.39 10.00 12.29 12.29 12.00 12.00 12.12 12.00 12.00 12.49 12.50 12.26 12.26 11.96 11.96 12.05 11.96 11.96 12.52 15.00 12.11 12.11 11.84 11.84 11.89 11.83 11.83 12.37 17.50 11.90 11.90 11.71 11.71 11.73 11.71 11.71 12.09 20.00 11.61 11.61 11.49 11.49 11.47 11.49 11.49 11.73 25.00 11.08 11.02 11.01 11.01 10.97 11.00 11.00 11.05 30.00 10.44 10.43 10.54 10.54 10.64 10.54 10.54 10.62 35.00 9.96 9.95 10.07 10.07 10.17 10.07 10.07 10.19 40.00 9.52 9.52 9.63 9.63 9.70 9.63 9.64 9.77 45.00 9.14 9.13 9.24 9.24 9.27 9.24 9.24 9.36 50.00 8.80 8.72 8.87 8.87 8.88 8.87.
8.87 8.96 55.00 8.48 8.27 8.53 8.52 8.52 8.53 8.53
'8.56 57.19 8.08 57.43 8.37 57.53 8.38 8.38 8.38 57.55 8.38 8.38 58.06 8.33 NOTE: A UN indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point in each column. MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.
Page 14 of 29
T NINE MILE POINT UNIT 2 COLR2-10, Revision 0 Cycle 10 Table In MOST LIMIING MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Average MAPLHGR Limits (kwlft)
Planar PrOCNAB406-P1OCNAB404-PIOCNAB403-P9CU1B349
- Exposure, 2674 2675 2676 (GEl)
GWd/ST (GE14C)
(GE14C)
(GE14C) 0.00 9.75 9.72 9.52 11.11 0.20 9.82 9.78 9.62 11.17 1.00 9.92 9.87 9.75 11.31 2.00 10.04 9.98 9.89 11.52 3.00 10.16 10.12 10.02 11.74 4.00 10.28 10.29 10.16 11.98 5.00 10.40 10.44 10.30 12.23 6.00 10.53 10.61 10.44 12.42 7.00 10.66 10.76 10.58 12.59 8.00 10.79 10.89 10.73 12.69 9.00 10.93 11.02 10.88 12.78 10.00 11.07 11.16 11.03 12.85 11.00 11.20 11.29 11.18 12.00 11.25 11.35 11.22 12.50 12.77 13.00 11.26 11.35 11.24 14.00 11.23 11.34 11.25 14.51 11.20 11.33 11.22 15.00 11.18 11.33 11.19 12.39 17.00 11.06 11.23 11.06 17.50 12.00 19.13 10.89 11.08 10.88 20.00 10.82
- 11.01 10.81 11.61 25.00 10.36 10.52 10.33 10.84 30.00 9.88 10.02 9.85 10.10 35.00 9.40 9.51 9.37 9.40 40.00 8.91 8.99 8.88 8.75 45.00 8.40 8.47 8.37 8.12 50.00 7.86 7.92 7.83 7.51 55.00 5.94 6.12 5.88 6.81 57.11
_4.83 57.19 4.85 57.39 6.47 57.52 4.85 NOTE: A '-"
indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point in each column. MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.
Page 15 of 29
Revision 0 Cycle 10 NINE MILE POINT UNIT 2 CORE OPERATING LIMITS REPORT 2.0 MINMUM CRMTICAL POWER RATIO (ODYN OPTION B) 2.1 Limits for Technical Specification 3.2.2 The Minimum Critical Power Ratio (MCPR) shall be equal to or greater than the appropriate MCPR limit from Figures 2a and 2b times the K(Q shown in Figure 2c with tau (or x) defined as follows:
X = ('rave - 'CB) / (MA -)
where:
sA = 0.866 seconds, control rod average scram insertion time limit to notch 39 per Specification 3.1.4.
TR =.672 + 1.65*[ N, IY£ N1 m l*.016 a
D tersee (YN, i, ) /(E-N I I-X I-I n =-number of surveillance tests performed in cycle N. = number of active control rods measured in the i surveillance test xi average scram time to notch 39 of all rods measured in the is surveillance test N. = total number of active rods measured in Specification 3.1.4.1.
NOTES:
- 1. The MCPR Operating Limits in Figures 2a and 2b are based on a 1.07 Safety Limit MCPR (SLMCPR) for two recirculation loop operation and a 1.09 Safety Limit MCPR for single loop operation.
- 2. c = 1.0 prior to performance of the initial scram time measurements for the cycle.
or equal to the standard normal operation case, and are therefore specifically identified in Figure 2a. The GE14C Operating Limit MCPR values for Turbine Bypass Out of Service and EOC-RPT Out of Service are higher (more limiting) than for the standard normal operation case, and are therefore specifically identified in Figure 2b.The OLMCPR values for all other analyzed EOOS transient events are bounded by the Normal Operation limits.
- 4. For operation between 30% and 90% RTP with a backup pressure regulator out of service, additional MCPR limit requirements have been established. For operation >70%
but <90% RTP maintain MCPR > normal operation MCPR limit from Figures 2a and 2b divided by the fraction of rated thermal power. For operation ?30% and <70% RTP the additional requirements are established in Figures 2d and 2e. There are no additional MCPR limits required for operation <30% and >90% RTP with a backup pressure regulator out of service.
Page 16 of 29
I A
Figure 2a Nine Mile Point 2 Cycle 10 BOC to EOC
-GE1I MCPR Operating Limits 1.42 1.41 1.4 1.39 0:
U
.° 1.38
- a. 1.37 U
4-U E 1.36 S
1.35 1.34 1.33 1.32
/
EOC-RPT Inoperable Normal Operation and Turbine Bypass Inoperable I
0 0
0.2 0.4 0.6 0.8 I
Tau Page 17 of 29
Figure 2b Nine Mile Point 2 Cycle 10 BOC to EOC GE14C MCPR Operating Limits 1.65 -
(11
,163
.2; 1.55 E.C-RPT Inopera ble 1.45 1
0.45 (0,1.42) 00.2 0.4 0.6 0.8I Tau Page 18 of 29
NINE MILE POINT 2NIT 2
Figure 2c COLR2-10, Revision 0 Cycle 10 4
Kf vs Core Flow 1.4 1.2 1
0.8 0.6 0.4 0.2 0
(20,1.2840)
(73,1.(100,1.0)
(105,1.0)
A-20 30 40 50 60 70 80 90 100 110 Core Flow, % of rated Page 19 of29
¶NINE MILE POINT UNIT 2 COLR2-10, Revision 0 Cycle 10 Figure 2d GEII MCPR Limits for Operation Between 30% and 70% RTP Without a Backup Pressure Regulator Yz z I
I 21 2 I Oeratig MCPR *all be 2 MCPR mW One § Operatng Umt MCPR (P) =
For 30% s PS 70%
OLMCPR(P) t1.55+0.0075(70%-P)i r
1.9 I 1.8 1.7 1.6 1.5 ACC PTA LE REGIO -
R STRCTE REG ION E ter ch. pec. 3.2.2
.,I4 4 I 30 35 40 45 50 55 60 65 70 Core Thermal Power (P) In units of 1 Rated Thermal Power (%RTP)
Page 20 of 29
"TINE MILE POINT UNIT 2 COLR2-10, Revision 0
-Cyde 10 Figure 2e GE14C MCPR Limits for Operation Between 30% and 70% RTP Without a Backup Pressure Regulator a.
30 35 40 45 so 55 60 65 70 Core Thermal Power (P) In units of % Rated Thernal Power (%RTP)
Page 21 of 29
Revision 0 Cycle 10 NINE MIE POINT UNIT 2 CORE OPERATING LIMITS REPORT 3.0 LINEAR HEAT GENERATION RATE (LHGR) 3.1 Limits for Technical Specification 3.2.3 The LHGR shall not exceed the limits in the table below.
Fuel Type LHGR Limits GEl l 14.4 KW/FT GE14 13.4 KW/FT NOTE:
For operation >30%/c and <90% RTP with a backup pressure regulator out of service, additional LHGR limit requirements have been established as shown in Figure 3. There are no additional LHGR limits required for operation <30% and
>90%/6 RTP for operation with a backup pressure regulator out of service.
Page 22 of 29
IN ML PoI uNT2 COLR2-10, Revision 0 Cycle 10 4.
Figure 3 LHGR ULmit for Operation Between 30% and 90% RTP Without a Backup Pressure Regulator for GE14C and GE1I Q9. I FLES FRl TE? REEGIC 0.9 0.85 0.8 a
0.75 0.7 0.6 me r T_
Z.
XT CTI 70I 7,-
CC PT B ER GIN Operatng MFLPD shall beS MFLPD 0nit In MFLPD LUnilt For 30% S P S 70%
MFLPD - 10.85-0.0035(70%-P)J For 70% S P - 90 %:
- FRTP 30 35 40 45 50 55 60
- 65 70 75 Core Thermal Power (P) In units of % Rated Thermal Power (%RTP) 80 85 g0 Page 23 of 29
Revision 0 Cycle 10 NINE MILE POINT UNIT 2 CORE OPERAT ING LIMITS REPORT 4.0 AVERAGE POWER RANGE MONITOR SETPOINTS 4.1 Limits for Technical Specification Table 3.3.1.1-1 (OPRM Upscale!
ALLOWABLE VALUE < 1.13 Page 24 of 29
Revision 0 Cycle 10 NINE MILE POINT UNIT 2 CORE OPERA TING LIMITS REPORT -
5.0 ROD BLOCK MONITOR (RBM) 5.1 Allowable Value for Technical Specification Table 3.3.2. 1-1 Function Allowable Value RBM Upscale
- 0.66 (W - AW) + 47%
with a maximum of 113%
NOTE:
W = Loop Recirculation Flow as a percentage of the loop recirculation flow which produces a rated core flow of 108.5 MLBHR. AW is defined as the difference in indicated drive flow (in percent of drive flow which produces rated core flow) between two loop and single loop operation at the same core flow. AW =0 for two loop operation. AW -5% for single loop operation.
Page 25 of 29
Revision 0 Cycle 10 NINE MILE POINT UNIT 2 CORE OPERATING LIMHTS REPORT
6.0 REFERENCES
FOR TECHNICAL SPECIFICATION Technical Specification 5.6.5.b. 1:
General Electric Standard Application for Reactor Fuel, NEDE 2401 1-P-A-14 and NEDE 2401 1-P-A-14-US (June 2000).
Page 26 of 29
Revision 0 Cycle 10 NINE MILE POIN UNIT 2 CORE OPERATING LIMITS REPORT
7.0 REFERENCES
FOR TECHNICAL SPECIFICATION BASES 2.1.1 BASES REFERENCE 3:
General Electric Standard Application for Reactor Fuel, NEDE 2401 1-P-A-14 and NEDE 2401 1-P-A-14-US (June 2000).
2.1.1 BASES REFERENCE 4:
Supplemental Reload Licensing Report for Nine Mile Point Nuclear Station Unit 2, Reload 9, Cycle 10, 0000-0017-0888-SRLR, Rev. 0, March 2004.
3.1.1 BASES REFERENCE 7:
General Electric Standard Application for Reactor Fuel, NEDE 2401 1-P-A-14 and NEDE 2401 1-P-A-14-US (June 2000).
3.1.6 BASES REFERENCE 1:
Supplemental Reload Licensing Report for Nine Mile Point Nuclear Station Unit 2, Reload 9, Cycle 10, 0000-0017-0888-SRLR, Rev. 0, March 2004.
3.2.1 BASES REFERENCE 1:
General Electric Standard Application for Reactor Fuel, NEDE 2401 1-P-A-14 and NEDE 2401 1-P-A-14-US (June 2000).
3.2.2 BASES REFERENCE 2:
General Electric Standard Application for Reactor Fuel, NEDE 2401 1-P-A-14 and NEDE 24011-P-A-14-US (June 2000).
3.2.2 BASES REFERENCE 3:
Supplemental Reload Licensing Report for Nine Mile Point Nuclear Station Unit 2, Reload 9, Cycle 10, 0000-0017-0888-SRLR, Rev. 0, March 2004.
3.2.3 BASES REFERENCE 1:
General Electric Standard Application for Reactor Fuel, NEDE 2401 1-P-A-14 and NEDE 2401 1-P-A-14US (June 2000).
3.2.3 BASES REFERENCE 2:
Supplemental Reload Licensing Report for Nine Mile Point Nuclear Station Unit 2, Reload 9, Cycle 10, 0000-0017-0888-SRLR, Rev. 0, March 2004.
3.2.4 BASES REFERENCE 3:
General Electric Standard Application for Reactor Fuel, NEDE 2401 I-P-A-14 and NEDE 2401 1-P-A-14-US (June 2000).
Page 27 of 29
Revision 0 Cycle 10 b* I NE MIE POINT UNIT 2 CORE OPERATING LIMITS REPORT 8.0 SOURCE DOCUMENTS The Core Operating Limits contained in this report were obtained from the following documents:
CORE OPERATING LIMIT REFERENCE Section 1.0 - APLHGR LIMITS Tables Ia through In and corresponding single loop multiplier Section 2.0 - MCPR LIMITS Section 3.0 - LHGR LIMITS Pressure Regulator Out of Service Lattice Dependent MAPLHGR Report for NMP2 Reload 9, Cycle 10, 0000-0017-0888-MAPL, Revision 0, March 2004, "Supplemental Reload Licensing Report for Mine Mile Point Nuclear Station Unit 2, Reload 9, Cycle 10", 0000-0017-0888-SRLR, Rev 0, March 2004, and "Engineering Report for Nine Mile Point Nuclear Station Unit 2, Reload 9, Cycle 10",
0000-0024-9933-ER, Rev 0, March 2004 "Supplemental Reload Licensing Report for Nine Mile Point Nuclear Station Unit 2, Reload 9, Cycle 10", 0000-0017-0888-
- SRIL, Rev 0, March 2004, and "Engineering Report for Mine Mile Point Nuclear Station Unit 2, Reload 9, Cycle 10",
0000-0024-9933-ER, Rev 0, March 2004 "Supplemental Reload Licensing Report for Nine Mile Point Nuclear Station Unit 2, Reload 9, Cycle 10", 0000-0017-0888-SRIR, Rev 0, March 2004 "Engineering Report for Nine Mle Point Nuclear Station Unit 2, Reload 9, Cycle 10",
0000-0024-9933-ER, Rev 0, March 2004 Page 28 of 29
f
- 0
.4 A'w v - >
Revision 0 Cycle 10 NINE MILE POINT UNIT 2 CORE OPERATING LIMITS REPORT 8.0 SOURCE DOCUMENTS (Cont)
CORE OPERATING LIMIT
.E N Section 4.0 - APRM SETPOINTS Limits for Technical Specification Table 3.3.1.1-1 (OPRM Upscale)
Section 5.0 - RBM SETPOINTS "Supplemental Reload Licensing Report for Nine Mile Point Station Unit 2, Reload 9, Cycle 10", 0000-0017-0888-SRLR, Rev 0, March 2004 GE Engineering Report for Nine Mile Point Nuclear Station Unit 2 Reload 2 Cycle 3, NFD92-016 January 1992 Page 29 of 29