ML041000245

From kanterella
Jump to navigation Jump to search

FHA for MOX LTA
ML041000245
Person / Time
Site: Catawba  
(NPF-035, NPF-052)
Issue date: 03/30/2004
From: Lavie S
Division of Systems Safety and Analysis
To:
LaVie, Steve, NRR/DSSA/SPSB, 415-1081
References
TAC MB7863, TAC MB7864
Download: ML041000245 (16)


Text

MathCad Worksheet TAC:

S.F. LaVie, NRR/DSSA/SPSB MB7863,MB7864 Catawba FHA for MOX LTA INITIALIZATIONS Ci 3.7 1010 sec 1 rem 100 erg gm Bq 1.0 sec 1 MWt 1.0 106 watt ORIGIN 1

uCi 1.0 10 6 Ci mrem 0.001 rem Sv 100 rem kr85 3

I131 13 j

1 12 i 13 17 k

1 17 Read in nuclide database NUCLIDE.DAT.>>>>>

Re-assign arrays and assign units M

READPRN(

)

nuclide

M 2

sec 1

======================================================================
======================================================================

INPUT DATA Fuel assembly activity, Ci, From Staff S/T report Table 7 Kr83m Kr85m Kr85 Kr87 Kr88 Xe131m Xe133m Xe133 Xe135m Xe135 Xe137 Xe138 I131 I132 I133 I134 I135 Radial peaking factor:

k p 1.65 Decay Time T decay 72 hr Assign gap fractions:

F gk 0.075 noble gases and iodines A core 4.2840 104 7.8550 104 4.0430 103 1.4910 105 2.0010 105 7.5110 103 3.2540 104 9.8000 105 2.3070 105 5.3860 105 0.0 7.6430 105 5.1950 105 7.4150 105 9.7630 105 1.0420 106 9.2860 105 Ci F gI131 0.12 Increased 50% as done by licensee F gkr85 0.15 Assign pool DF:

DFj 1.0 DFi 1

200 catwbaFHA_MOX.mcd 3/30/1904 1

CALCULATION Activity available for release:

A relk A corek k p DFk F gk e

k T decay RG1.183 (RG1.25) stipulates that the activity is released over a two hour period. While it is typical to model an offsite release as a puff release of the total release inventory.

However, for a control room assessment, the release must be expressed in terms of a rate. We'll assume that 99% is released in two hours.

Kr83m Kr85m Kr85 Kr87 Kr88 Xe131m Xe133m Xe133 Xe135m Xe135 Xe137 Xe138 I131 I132 I133 I134 I135 A o 1.0 A f A o e t

=

A rel 7.603 10 9 0.141 1 103 1.667 10 13 5.782 10 4 780.465 1.557 103 8.158 104 0

275.025 0

0 397.096 1.73 10 7 54.836 0

0.302 Ci A f 0.01 solve for t

2 hr

ln A f A o t

=

5.526 103 day catwbaFHA_MOX.mcd 3/30/1904 2

RNEditor v1.0 File Name:

C:\\Documents and Settings\\Normal\\My Documents\\A_NRC\\MOX\\CatawbaMOX_FHA.RFT C:\\Documents and Settings\\Normal\\My Documents\\A_NRC\\MOX\\CatawbaMOX_FHA.NIF Description Catawba FHA with MOX assembly 50% higher gao fractions RELEASE FRACTION Duration, hr 1.0000E-04 0.0000E+00 0.0000E+00 0.0000E+00 Noble Gases:

1.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Iodine:

1.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Cesium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Tellurium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Strontium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Barium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Ruthenium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Cerium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Lanthanium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Non-Radioactive Aerosols (kg):

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 ACTIVITY, Ci (Stored in NIF File as Ci/MWt)

Co-58 0.0000E+00 Co-60 0.0000E+00 Kr-83m 0.0000E+00 Kr-85 1.0001E+03 Kr-85m 1.4101E-01 Kr-87 0.0000E+00 Kr-88 0.0000E+00 Rb-86 0.0000E+00 Sr-89 0.0000E+00 Sr-90 0.0000E+00 Sr-91 0.0000E+00 Sr-92 0.0000E+00 Y-90 0.0000E+00 Y-91 0.0000E+00 Y-92 0.0000E+00 Y-93 0.0000E+00 Zr-95 0.0000E+00 Zr-97 0.0000E+00 Nb-95 0.0000E+00 Mo-99 0.0000E+00 Tc-99m 0.0000E+00 Ru-103 0.0000E+00 Ru-105 0.0000E+00 Ru-106 0.0000E+00 Rh-105 0.0000E+00 Sb-127 0.0000E+00 Sb-129 0.0000E+00 Te-127 0.0000E+00 Te-127m 0.0000E+00 Te-129 0.0000E+00 Te-129m 0.0000E+00 Te-131m 0.0000E+00 Te-132 0.0000E+00 I-131 3.9704E+02 I-132 0.0000E+00 I-133 5.4849E+01 I-134 0.0000E+00 I-135 3.0201E-01 Xe-131m 7.8044E+02 Xe-133 8.1591E+04 Xe-133m 1.5571E+03 Xe-135 2.7503E+02 Xe-135m 0.0000E+00 Xe-138 0.0000E+00 Cs-134 0.0000E+00 Cs-136 0.0000E+00 Cs-137 0.0000E+00 Ba-139 0.0000E+00 Ba-140 0.0000E+00 La-140 0.0000E+00 La-141 0.0000E+00 La-142 0.0000E+00 Ce-141 0.0000E+00 Ce-143 0.0000E+00 Ce-144 0.0000E+00 Pr-143 0.0000E+00 Nd-147 0.0000E+00 Np-239 0.0000E+00 Pu-241 0.0000E+00 Cm-242 0.0000E+00

RADTRAD Version 3.03 (Spring 2001) run on 12/27/2003 at 0:01:13 File information Plant file = C:\\Documents and Settings\\Normal\\My Documents\\A_NRC\\MOX\\catawbaFHA_mOX.psf Inventory file = C:\\Documents and Settings\\Normal\\My Documents\\A_NRC\\MOX\\CatawbaMOX_FHA.NIF Release file = C:\\Documents and Settings\\Normal\\My Documents\\A_NRC\\MOX\\CatawbaMOX_FHA.RFT Dose Conversion file = c:\\program files\\radtrad3.03\\defaults\\dba_fg11&12.inp Radtrad 3.03 4/15/2001 Nuclide Inventory File:

C:\\Documents and Settings\\Normal\\My Documents\\A_NRC\\MOX\\CatawbaMOX_FHA.NIF Plant Power Level:

3.4110E+03 Compartments:

3 Compartment 1:

FHB/CNMT 3

1.0000E+00 0

0 0

0 0

Compartment 2:

Environm 2

0.0000E+00 0

0 0

0 0

Compartment 3:

Control Room 1

1.1790E+05 0

0

1 0

0 Pathways:

4 Pathway 1:

FHB/CNMT to Environm 1

2 4

Pathway 2:

Environm to Control Room-unfilt 2

3 2

Pathway 3:

Environm to Control Room Filt 2

3 2

Pathway 4:

Control Room to Environm 3

2 2

End of Plant Model File Scenario Description Name:

Plant Model Filename:

Source Term:

1 1 1.0000E+00 c:\\program files\\radtrad3.03\\defaults\\dba_fg11&12.inp C:\\Documents and Settings\\Normal\\My Documents\\A_NRC\\MOX\\CatawbaMOX_FHA.RFT 0.0000E+00 0

0.0000E+00 5.7000E-01 4.3000E-01 1.0000E+00 Overlying Pool:

0 0.0000E+00 0

0 0

0 Compartments:

3 Compartment 1:

0 1

0 0

0 0

0 0

0 Compartment 2:

0 1

0

0 0

0 0

0 0

Compartment 3:

0 1

0 0

0 0

1 1.5000E+03 3

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 5.0000E-01 9.9000E+01 9.9000E+01 9.5000E+01 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0

0 Pathways:

4 Pathway 1:

0 0

0 0

0 0

0 0

0 0

1 2

0.0000E+00 5.5260E+03 2.0000E+00 0.0000E+00 0

Pathway 2:

0 0

0 0

0 1

3 0.0000E+00 2.1000E+03 0.0000E+00 0.0000E+00 0.0000E+00 5.0000E-01 1.0000E+02 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 3:

0 0

0 0

0 1

3 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 5.0000E-01 2.0000E+03 9.9000E+01 9.9000E+01 9.5000E+01 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 4:

0 0

0 0

0 1

3 0.0000E+00 2.1000E+03 1.0000E+02 1.0000E+02 1.0000E+02 5.0000E-01 2.1000E+03 1.0000E+02 1.0000E+02 1.0000E+02 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Dose Locations:

3 Location 1:

EAB 2

1 2

0.0000E+00 4.7800E-04 2.0000E+00 0.0000E+00 1

4 0.0000E+00 3.4700E-04 8.0000E+00 1.7500E-04 2.4000E+01 2.3200E-04 7.2000E+02 0.0000E+00 0

Location 2:

LPZ 2

1 2

0.0000E+00 6.8500E-05 2.0000E+00 0.0000E+00 1

4 0.0000E+00 3.4700E-04 8.0000E+00 1.7500E-04 2.4000E+01 2.3200E-04 7.2000E+02 0.0000E+00 0

Location 3:

Control Room

3 0

1 2

0.0000E+00 3.4700E-04 7.2000E+02 0.0000E+00 1

4 0.0000E+00 1.0000E+00 2.4000E+01 6.0000E-01 9.6000E+01 4.0000E-01 7.2000E+02 0.0000E+00 Effective Volume Location:

1 2

0.0000E+00 1.0400E-03 2.0000E+00 0.0000E+00 Simulation Parameters:

1 0.0000E+00 0.0000E+00 Output Filename:

C:\\Documents and Settings\\Normal\\My Documents\\A_NRC\\MOX\\catawbaFHA_mOX.o9 1

1 1

0 0

End of Scenario File RADTRAD Version 3.03 (Spring 2001) run on 12/27/2003 at 0:01:13 Plant Description Number of Nuclides = 60 Inventory Power = 1.0000E+00 MWth Plant Power Level = 3.4110E+03 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction = 1.0000E+00

)

Name: FHB/CNMT Compartment volume = 1.0000E+00 (Cubic feet)

Compartment type is Normal Pathways into and out of compartment 1 Exit Pathway Number 1: FHB/CNMT to Environm Compartment number 2 Name: Environm Compartment type is Environment Pathways into and out of compartment 2 Inlet Pathway Number 1: FHB/CNMT to Environm Inlet Pathway Number 4: Control Room to Environm

Exit Pathway Number 2: Environm to Control Room-unfilt Exit Pathway Number 3: Environm to Control Room Filt Compartment number 3 Name: Control Room Compartment volume = 1.1790E+05 (Cubic feet)

Compartment type is Control Room Removal devices within compartment:

Filter(s)

Pathways into and out of compartment 3 Inlet Pathway Number 2: Environm to Control Room-unfilt Inlet Pathway Number 3: Environm to Control Room Filt Exit Pathway Number 4: Control Room to Environm Total number of pathways = 4 RADTRAD Version 3.03 (Spring 2001) run on 12/27/2003 at 0:01:13 Scenario Description Radioactive Decay is enabled Release Fractions and Timings GAP EARLY IN-VESSEL LATE RELEASE RELEASE MASS 0.000100 hr 0.0000 hrs 0.0000 hrs (gm)

NOBLES 1.0000E+00 0.0000E+00 0.0000E+00 2.985E+00 IODINE 1.0000E+00 0.0000E+00 0.0000E+00 3.251E-03 CESIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 TELLURIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 STRONTIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 BARIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 RUTHENIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 CERIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 LANTHANUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 Inventory Power = 3411. MWt Nuclide Group Specific half Whole Body Inhaled Inhaled Name Inventory life DCF Thyroid Effective (Ci/MWt) (s) (Sv-m3/Bq-s) (Sv/Bq) (Sv/Bq)

Kr-85 1 2.932E-01 3.383E+08 1.190E-16 0.000E+00 0.000E+00 Kr-85m 1 4.134E-05 1.613E+04 7.480E-15 0.000E+00 0.000E+00 I-131 2 1.164E-01 6.947E+05 1.820E-14 2.920E-07 8.890E-09 I-133 2 1.608E-02 7.488E+04 2.940E-14 4.860E-08 1.580E-09 I-135 2 8.854E-05 2.380E+04 8.294E-14 8.460E-09 3.320E-10 Xe-131m 1 2.288E-01 1.023E+06 7.890E-16 0.000E+00 0.000E+00 Xe-133 1 2.392E+01 4.532E+05 1.560E-15 0.000E+00 0.000E+00 Xe-133m 1 4.565E-01 1.892E+05 2.160E-15 0.000E+00 0.000E+00 Xe-135 1 8.063E-02 3.272E+04 1.190E-14 0.000E+00 0.000E+00 Iodine fractions Aerosol = 0.0000E+00 Elemental = 5.7000E-01 Organic = 4.3000E-01 COMPARTMENT DATA

Compartment number 1: FHB/CNMT Compartment number 2: Environm Compartment number 3: Control Room Compartment Filter Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 1.5000E+03 0.0000E+00 0.0000E+00 0.0000E+00 5.0000E-01 1.5000E+03 9.9000E+01 9.9000E+01 9.5000E+01 7.2000E+02 1.5000E+03 0.0000E+00 0.0000E+00 0.0000E+00 PATHWAY DATA Pathway number 1: FHB/CNMT to Environm Convection Data Time (hr) Flow Rate (% / day) 0.0000E+00 5.5260E+03 2.0000E+00 0.0000E+00 Pathway number 2: Environm to Control Room-unfilt Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 2.1000E+03 0.0000E+00 0.0000E+00 0.0000E+00 5.0000E-01 1.0000E+02 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 3: Environm to Control Room Filt Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 5.0000E-01 2.0000E+03 9.9000E+01 9.9000E+01 9.5000E+01 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 4: Control Room to Environm Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 2.1000E+03 1.0000E+02 1.0000E+02 1.0000E+02 5.0000E-01 2.1000E+03 1.0000E+02 1.0000E+02 1.0000E+02 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 LOCATION DATA Location EAB is in compartment 2 Location X/Q Data Time (hr) X/Q (s

  • m^-3) 0.0000E+00 4.7800E-04 2.0000E+00 0.0000E+00

Location Breathing Rate Data Time (hr) Breathing Rate (m^3

  • sec^-1) 0.0000E+00 3.4700E-04 8.0000E+00 1.7500E-04 2.4000E+01 2.3200E-04 7.2000E+02 0.0000E+00 Location LPZ is in compartment 2 Location X/Q Data Time (hr) X/Q (s
  • m^-3) 0.0000E+00 6.8500E-05 2.0000E+00 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.4700E-04 8.0000E+00 1.7500E-04 2.4000E+01 2.3200E-04 7.2000E+02 0.0000E+00 Location Control Room is in compartment 3 Location X/Q Data Time (hr) X/Q (s
  • m^-3) 0.0000E+00 1.0400E-03 2.0000E+00 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.4700E-04 7.2000E+02 0.0000E+00 Location Occupancy Factor Data Time (hr) Occupancy Factor 0.0000E+00 1.0000E+00 2.4000E+01 6.0000E-01 9.6000E+01 4.0000E-01 7.2000E+02 0.0000E+00 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step 0.0000E+00 0.0000E+00

RADTRAD Version 3.03 (Spring 2001) run on 12/27/2003 at 0:01:13 Dose Output EAB Doses:

Time (h) = 0.0001 Whole Body Thyroid TEDE Delta dose (rem) 2.9219E-05 8.3790E-03 2.8471E-04 Accumulated dose (rem) 2.9219E-05 8.3790E-03 2.8471E-04 LPZ Doses:

Time (h) = 0.0001 Whole Body Thyroid TEDE Delta dose (rem) 4.1873E-06 1.2008E-03 4.0801E-05 Accumulated dose (rem) 4.1873E-06 1.2008E-03 4.0801E-05 Control Room Doses:

Time (h) = 0.0001 Whole Body Thyroid TEDE Delta dose (rem) 1.4995E-10 9.7412E-07 2.9853E-08 Accumulated dose (rem) 1.4995E-10 9.7412E-07 2.9853E-08 EAB Doses:

Time (h) = 0.5000 Whole Body Thyroid TEDE Delta dose (rem) 1.7332E-01 4.9725E+01 1.6895E+00 Accumulated dose (rem) 1.7334E-01 4.9734E+01 1.6898E+00 LPZ Doses:

Time (h) = 0.5000 Whole Body Thyroid TEDE Delta dose (rem) 2.4837E-02 7.1259E+00 2.4212E-01 Accumulated dose (rem) 2.4841E-02 7.1271E+00 2.4216E-01 Control Room Doses:

Time (h) = 0.5000 Whole Body Thyroid TEDE Delta dose (rem) 4.3393E-03 2.8213E+01 8.6460E-01 Accumulated dose (rem) 4.3393E-03 2.8213E+01 8.6460E-01 EAB Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE

Delta dose (rem) 7.7257E-02 2.2214E+01 7.5457E-01 Accumulated dose (rem) 2.5060E-01 7.1948E+01 2.4444E+00 LPZ Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.1071E-02 3.1834E+00 1.0813E-01 Accumulated dose (rem) 3.5913E-02 1.0310E+01 3.5029E-01 Control Room Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.4227E-02 4.5631E+01 1.4056E+00 Accumulated dose (rem) 1.8567E-02 7.3845E+01 2.2702E+00 EAB Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 2.5060E-01 7.1948E+01 2.4444E+00 LPZ Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 3.5913E-02 1.0310E+01 3.5029E-01 Control Room Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.5428E-03 3.4359E+00 1.0930E-01 Accumulated dose (rem) 2.3109E-02 7.7280E+01 2.3795E+00 EAB Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 2.5060E-01 7.1948E+01 2.4444E+00 LPZ Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 3.5913E-02 1.0310E+01 3.5029E-01 Control Room Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 7.1319E-06 6.4484E-05 9.0975E-06 Accumulated dose (rem) 2.3117E-02 7.7281E+01 2.3795E+00 EAB Doses:

Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 2.5060E-01 7.1948E+01 2.4444E+00 LPZ Doses:

Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00

Accumulated dose (rem) 3.5913E-02 1.0310E+01 3.5029E-01 Control Room Doses:

Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.1978E-13 3.6281E-17 3.1978E-13 Accumulated dose (rem) 2.3117E-02 7.7281E+01 2.3795E+00 EAB Doses:

Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 2.5060E-01 7.1948E+01 2.4444E+00 LPZ Doses:

Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 3.5913E-02 1.0310E+01 3.5029E-01 Control Room Doses:

Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 5.4194E-47 9.8268E-74 5.4194E-47 Accumulated dose (rem) 2.3117E-02 7.7281E+01 2.3795E+00 308 I-131 Summary FHB/CNMT Environm Control Room Time (hr) I-131 (Curies) I-131 (Curies) I-131 (Curies) 0.000 3.9699E+02 4.5706E-02 4.7109E-05 0.401 1.5762E+02 2.3900E+02 1.9383E-01 0.500 1.2535E+02 2.7122E+02 2.0569E-01 0.800 6.2758E+01 3.3370E+02 1.2287E-01 1.100 3.1420E+01 3.6498E+02 7.3062E-02 1.400 1.5731E+01 3.8064E+02 4.3279E-02 1.700 7.8758E+00 3.8849E+02 2.5557E-02 2.000 3.9431E+00 3.9241E+02 1.5052E-02 2.300 3.9389E+00 3.9241E+02 8.7346E-03 2.600 3.9346E+00 3.9241E+02 5.0686E-03 2.900 3.9304E+00 3.9241E+02 2.9414E-03 3.200 3.9261E+00 3.9241E+02 1.7069E-03 3.500 3.9219E+00 3.9241E+02 9.9058E-04 3.800 3.9177E+00 3.9241E+02 5.7488E-04 4.100 3.9135E+00 3.9241E+02 3.3363E-04 4.400 3.9093E+00 3.9241E+02 1.9363E-04 4.700 3.9051E+00 3.9241E+02 1.1238E-04 5.000 3.9008E+00 3.9241E+02 6.5224E-05 5.300 3.8966E+00 3.9241E+02 3.7856E-05 5.600 3.8924E+00 3.9241E+02 2.1972E-05 5.900 3.8883E+00 3.9241E+02 1.2753E-05 6.200 3.8841E+00 3.9241E+02 7.4026E-06 6.500 3.8799E+00 3.9241E+02 4.2968E-06 6.800 3.8757E+00 3.9241E+02 2.4942E-06 7.100 3.8715E+00 3.9241E+02 1.4478E-06 7.400 3.8674E+00 3.9241E+02 8.4044E-07 7.700 3.8632E+00 3.9241E+02 4.8787E-07

8.000 3.8590E+00 3.9241E+02 2.8322E-07 8.300 3.8549E+00 3.9241E+02 1.6441E-07 8.600 3.8507E+00 3.9241E+02 9.5449E-08 8.900 3.8466E+00 3.9241E+02 5.5413E-08 9.200 3.8424E+00 3.9241E+02 3.2171E-08 9.500 3.8383E+00 3.9241E+02 1.8677E-08 9.800 3.8342E+00 3.9241E+02 1.0844E-08 10.100 3.8300E+00 3.9241E+02 6.2959E-09 10.400 3.8259E+00 3.9241E+02 3.6555E-09 24.000 3.6435E+00 3.9241E+02 7.3849E-20 96.000 2.8132E+00 3.9241E+02 3.0299E-76 720.000 2.9908E-01 3.9241E+02 0.0000E+00 Cumulative Dose Summary EAB LPZ Control Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 0.000 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.401 4.3827E+01 1.4891E+00 6.2807E+00 2.1340E-01 2.0007E+01 6.1311E-01 0.500 4.9734E+01 1.6898E+00 7.1271E+00 2.4216E-01 2.8213E+01 8.6460E-01 0.800 6.1188E+01 2.0789E+00 8.7686E+00 2.9792E-01 4.8208E+01 1.4782E+00 1.100 6.6922E+01 2.2737E+00 9.5903E+00 3.2583E-01 6.0124E+01 1.8450E+00 1.400 6.9792E+01 2.3712E+00 1.0002E+01 3.3980E-01 6.7196E+01 2.0635E+00 1.700 7.1228E+01 2.4200E+00 1.0207E+01 3.4679E-01 7.1378E+01 2.1933E+00 2.000 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.3845E+01 2.2702E+00 2.300 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.5287E+01 2.3154E+00 2.600 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.6124E+01 2.3418E+00 2.900 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.6609E+01 2.3573E+00 3.200 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.6891E+01 2.3663E+00 3.500 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7055E+01 2.3717E+00 3.800 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7149E+01 2.3748E+00 4.100 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7204E+01 2.3767E+00 4.400 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7236E+01 2.3778E+00 4.700 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7255E+01 2.3784E+00 5.000 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7266E+01 2.3788E+00 5.300 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7272E+01 2.3791E+00 5.600 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7276E+01 2.3792E+00 5.900 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7278E+01 2.3793E+00 6.200 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7279E+01 2.3794E+00 6.500 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7280E+01 2.3794E+00 6.800 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7280E+01 2.3794E+00 7.100 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7280E+01 2.3794E+00 7.400 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7280E+01 2.3794E+00 7.700 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7280E+01 2.3794E+00 8.000 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7280E+01 2.3795E+00 8.300 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7280E+01 2.3795E+00 8.600 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7281E+01 2.3795E+00 8.900 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7281E+01 2.3795E+00 9.200 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7281E+01 2.3795E+00 9.500 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7281E+01 2.3795E+00 9.800 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7281E+01 2.3795E+00 10.100 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7281E+01 2.3795E+00 10.400 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7281E+01 2.3795E+00 24.000 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7281E+01 2.3795E+00 96.000 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7281E+01 2.3795E+00 720.000 7.1948E+01 2.4444E+00 1.0310E+01 3.5029E-01 7.7281E+01 2.3795E+00

Worst Two-Hour Doses EAB Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 0.0 2.5060E-01 7.1948E+01 2.4444E+00 Licensee obtained 2.3 at EAB, 0.34 at LPZ, and 2.1 in Control Room