Technical Specification Bases Change
ML040420044
Person / Time
Site: McGuire, Mcguire  
Issue date: 02/04/2004
From: Gordon Peterson
Duke Power Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML040420044 (14)


Text

Duke GARY R.

PETERSON

  • WPowere Vice President McGuire Nuclear Station A Duke Energy Company Duke Power MGO1 VP/ 12700 Hagers Ferry Road Huntersville, NC 28078-9340 704 875 5333 February 4, 2004 704 875 4809 fax grpeters@duke-energy.com U.S. Nuclear Regulatory Commission ATTENTION:

Document Control Desk Washington, DC 20555-0001

SUBJECT:

Duke Energy Corporation McGuire Nuclear Station Units 1 and 2 Docket Nos. 50-369 and 50-370 Technical Specification (TS) Bases Change Attached is a revision to McGuire Technical Specification Bases Manual Sections 3.7.14, "Spent Fuel Pool Boron Concentration,"

and 3.7.15, "Spent Fuel Assembly Storage."

The term "maximum tolerance of +/- 0.05 wt% U-235" is added to the U-235 enrichment amount of 4.75 wt%.

This clarifies "maximum nominal" and confirms that the tolerance amount is included in any applicable safety analysis. contains the revised TS Bases List of Effective Sections. contains revised TS Bases.

Please contact Norman T. Simms at (704) 875-4685 if you have any questions.

Very truly yours, G. R. Peterson Attachments f SD\\

www. duke-energy. corn

U. S. Nuclear Regulatory Commission February 4, 2004 Page 2 Xc w/attachments:

L. A. Reyes U. S. Nuclear Regulatory Commission Regional Administrator, Region II Atlanta Federal Center 61 Forsyth St., SW, Suite 23T85 Atlanta, GA 30303 R. E. Martin U. S. Nuclear Regulatory Commission Mail Stop 0-8G9 11555 Rockville Pike Rockville, MD 20852-2738 Beverly 0. Hall, Section Chief Radiation Protection Section 1645 Mail Service Center Raleigh, NC 27699-1645 J. B. Brady Senior Resident Inspector U. S. Nuclear Regulatory Commission McGuire Nuclear Station

ATTACHMENT 1 REVISED TECHNICAL SPECIFICATION BASES LIST OF EFFECTIVE SECTIONS

ATTACHMENT 2

REVISED TECHNICAL SPECIFICATION BASES 3.7.14, 3.7.15

Spent Fuel Pool Boron Concentration B 3.7.14 B 3.7 PLANT SYSTEMS B 3.7.14 Spent Fuel Pool Boron Concentration BASES BACKGROUND In the two region poison fuel storage rack (Refs. 1 and 2) design, the spent fuel pool is divided into two separate and distinct regions.

Region 1, with 286 storage positions, is designed and generally reserved for temporary storage of new or partially irradiated fuel. Region 2, with 1177 storage positions, is designed and generally used for normal, long term storage of permanently discharged fuel that has achieved qualifying burnup levels.

The McGuire spent fuel storage racks contain Boraflex neutron-absorbing panels that surround each storage cell on all four sides (except for peripheral sides). The function of these Boraflex panels is to ensure that the reactivity of the stored fuel assemblies is maintained within required limits. Boraflex, as manufactured, is a silicon rubber material that retains a powder of boron carbide (B4C) neutron absorbing material. The Boraflex panels are enclosed in a formed stainless steel wrapper sheet that is spot-welded to the storage tube. The wrapper sheet is bent at each end to complete the enclosure of the Boraflex panel. The Boraflex panel is contained in the plenum area between the storage tube and the wrapper plate. Since the wrapper plate enclosure is not sealed, spent fuel pool water is free to circulate through the plenum. It has been observed that after Boraflex receives a high gamma dose from the stored irradiated fuel (>1010 rads) it can begin to degrade and dissolve in the wet environment. Thus, the B4C poison material can be removed, thereby reducing the poison worth of the Boraflex sheets. This phenomenon is documented in NRC Generic Letter 96-04, "Boraflex Degradation in Spent Fuel Pool Storage Racks".

To address this degradation, each region of the spent fuel pool has been divided into two sub-regions; with and without credit for Boraflex. For the regions taking credit for Boraflex, a minimum amount of Boraflex was assumed that is less than the original design minimum Bl0 areal density.

The McGuire spent fuel storage racks have been analyzed taking credit for soluble boron as allowed in Reference 3. The methodology ensures that the spent fuel rack multiplication factor, keff, is less than or equal to 0.95 as recommended in ANSI/ANS-57.2-1983 (Ref. 4) and NRC guidance (Ref. 5). The spent fuel storage racks are analyzed to allow storage of fuel assemblies with enrichments up to a maximum nominal enrichment of 4.75 weight percent Uranium-235 (maximum tolerance of +

0.05 wt.%) while maintaining kef < 0.95 including uncertainties, McGuire Units 1 and 2 B 3.7.14-1 Revision No. 52

Spent Fuel Pool Boron Concentration B 3.7.14 BASES BACKGROUND (continued) tolerances, bias, and credit for soluble boron. Soluble boron credit is used to offset uncertainties, tolerances, and off-normal conditions and to provide subcritical margin such that the spent fuel pool keff is maintained less than or equal to 0.95. The soluble boron concentration required to maintain keff less than or equal to 0.95 under normal conditions is 850 ppm. In addition, sub-criticality of the pool (keff < 1.0) is assured on a 95/95 basis, without the presence of the soluble boron in the pool. The criticality analysis performed shows that the acceptance criteria for criticality is met for the storage of fuel assemblies when credit is taken for reactivity depletion due to fuel burnup, the presence of Integral Fuel Burnable Absorber (IFBA) rods, reduced credit for the Boraflex neutron absorber panels and storage configurations and enrichment limits Specified by LCO 3.7.15.

APPLICABLE SAFETY ANALYSES Most accident conditions do not result in an increase in reactivity of the racks in the spent fuel pool. Examples of these accident conditions are the drop of a fuel assembly on top of a rack, the drop of a fuel assembly between rack modules (rack design precludes this condition), and the drop of a fuel assembly between rack modules and the pool wall.

However, three accidents can be postulated which could result in an increase in reactivity in the spent fuel storage pools. The first is a drop or placement of a fuel assembly into the cask loading area. The second is a significant change in the spent fuel pool water temperature (either the loss of normal cooling to the spent fuel pool water which causes an increase in the pool water temperature or a large makeup to the pool with cold water which causes a decrease in the pool water temperature) and the third is the misleading of a fuel assembly into a location which the restrictions on location, enrichment, burnup and number of IFBA rods is not satisfied.

For an occurrence of these postulated accidents, the double contingency principle discussed in ANSI N-16.1-1975 and the April 1978 NRC letter (Ref. 6) can be applied. This states that one is not required to assume two unlikely, independent, concurrent events to ensure protection against a criticality accident. Thus, for these postulated accident conditions, the presence of additional soluble boron in the spent fuel pool water (above the 850 ppm required to maintain keff less than or equal to 0.95 under normal conditions) can be assumed as a realistic initial condition since not assuming its presence would be a second unlikely event.

Calculations were performed to determine the amount of soluble boron required to offset the highest reactivity increase caused by either of McGuire Units 1 and 2 B 3.7.14-2 Revision No. 52

Spent Fuel Pool Boron Concentration B 3.7.14 BASES APPLICABLE SAFETY ANALYSES (continued) these postulated accidents and to maintain ken less than or equal to 0.95.

It was found that a spent fuel pool boron concentration of 1470 ppm was adequate to mitigate these postulated criticality related accidents and to maintain keff less than or equal to 0.95. Specification 3.7.14 ensures the spent fuel pool contains adequate dissolved boron to compensate for the increased reactivity caused by these postulated accidents.

Specification 4.3.1.1 c. requires that the spent fuel rack ken be less than or equal to 0.95 when flooded with water borated to 850 ppm. A spent fuel pool boron dilution analysis was performed which confirmed that sufficient time is available to detect and mitigate a dilution of the spent fuel pool before the 0.95 ken design basis is exceeded. The spent fuel pool boron dilution analysis concluded that an unplanned or inadvertent event which could result in the dilution of the spent fuel pool boron concentration to 850 ppm is not a credible event.

The concentration of dissolved boron in the spent fuel pool satisfies Criterion 2 of 10 CFR 50.36 (Ref. 5).

LCO The spent fuel pool boron concentration is required to be within the limits specified in the COLR. The specified concentration of dissolved boron in the spent fuel pool preserves the assumptions used in the analyses of the potential criticality accident scenarios as described in Reference 4. This concentration of dissolved boron is the minimum required concentration for fuel assembly storage and movement within the spent fuel pool.

APPLICABILITY This LCO applies whenever fuel assemblies are stored in the spent fuel pool.

ACTIONS A.1 and A.2 The Required Actions are modified by a Note indicating that LCO 3.0.3 does not apply.

When the concentration of boron in the fuel storage pool is less than required, immediate action must be taken to preclude the occurrence of an accident or to mitigate the consequences of an accident in progress.

This is most efficiently achieved by immediately suspending the movement of fuel assemblies. The concentration of boron is restored simultaneously with suspending movement of fuel assemblies.

McGuire Units 1 and 2 B 3.7.1 4-3 Revision No. 52

Spent Fuel Assembly Storage B 3.7.14 BASES ACTIONS (continued)

If the LCO is not met while moving irradiated fuel assemblies in MODE 5 or 6, LCO 3.0.3 would not be applicable. If moving irradiated fuel assemblies while in MODE 1, 2, 3, or 4, the fuel movement is independent of reactor operation. Therefore, inability to suspend movement of fuel assemblies is not sufficient reason to require a reactor shutdown.

SURVEILLANCE SR 3.7.14.1 REQUIREMENTS This SR verifies that the concentration of boron in the spent fuel pool is within the required limit. As long as this SR is met, the analyzed accidents are fully addressed. The 7 day Frequency is appropriate because no major replenishment of pool water is expected to take place over such a short period of time.

REFERENCES

1.

UFSAR, Section 9.1.2.

2.

Issuance of Amendments, McGuire Nuclear Station, Units 1 and 2 (TAC NOS. MA9730 and MA9731), November 27, 2000.

3.

WCAP-14416-NP-A, Westinghouse Spent Fuel Rack Criticality Analysis Methodology, Revision 1, November 1996.

4.

American Nuclear Society, "American National Standard Design Requirements for Light Water Reactor Fuel Storage Facilities at Nuclear Power Plants," ANSI/ANS-57.2-1983, October 7,1983.

5.

Nuclear Regulatory Commission, Memorandum to Timothy Collins from Laurence Kopp, "Guidance on the Regulatory Requirements for Criticality Analysis of Fuel Storage at Light Water Reactor Power Plants," August 19, 1998.

6.

Double contingency principle of ANSI N16.1-1975, as specified in the April 14,1978 NRC letter (Section 1.2) and implied in the proposed revision to Regulatory Guide 1.13 (Section 1.4, Appendix A).

7.

10 CFR 50.36, Technical Specifications, (c)(2)(ii).

8.

UFSAR, Section 15.7.4.

McGuire Units 1 and 2 B 3.7.14-4 Revision No. 52

Spent Fuel Assembly Storage B 3.7.15 B 3.7 PLANT SYSTEMS B 3.7.15 Spent Fuel Assembly Storage BASES BACKGROUND In the two region poison fuel storage rack (Refs. 1 and 2) design, the spent fuel pool is divided into two separate and distinct regions.

Region 1, with 286 storage positions, is designed and generally reserved for temporary storage of new or partially irradiated fuel. Region 2, with 1177 storage positions, is designed and generally used for normal, long term storage of permanently discharged fuel that has achieved qualifying burnup levels.

The McGuire spent fuel storage racks contain Boraflex neutron-absorbing panels that surround each storage cell on all four sides (except for peripheral sides). The function of these Boraflex panels is to ensure that the reactivity of the stored fuel assemblies is maintained within required limits. Boraflex, as manufactured, is a silicon rubber material that retains a powder of boron carbide (B4C) neutron absorbing material. The Boraflex panels are enclosed in a formed stainless steel wrapper sheet that is spot-welded to the storage tube. The wrapper sheet is bent at each end to complete the enclosure of the Boraflex panel. The Boraflex panel is contained in the plenum area between the storage tube and the wrapper plate. Since the wrapper plate enclosure is not sealed, spent fuel pool water is free to circulate through the plenum. It has been observed that after Boraflex receives a high gamma dose from the stored irradiated fuel (>1010 rads) it can begin to degrade and dissolve in the wet environment. Thus, the B4C poison material can be removed, thereby reducing the poison worth of the Boraflex sheets. This phenomenon is documented in NRC Generic Letter 96-04, "Boraflex Degradation in Spent Fuel Pool Storage Racks".

To address this degradation, each region of the spent fuel pool has been divided into two sub-regions; with and without credit for Boraflex. For the regions taking credit for Boraflex, a minimum amount of Boraflex was assumed that is less than the original design minimum B10 areal density.

Two storage configurations are defined for each region; Unrestricted and Restricted storage. Unrestricted storage allows storage in all cells without restriction on the storage configuration. Restricted storage allows storage of higher reactivity fuel when restricted to a certain storage McGuire Units 1 and 2 B 3.7.15-1 Revision No. 52

Spent Fuel Assembly Storage B 3.7.15 BASES BACKGROUND (continued) configuration with lower reactivity fuel. A third loading pattern, Checkerboard storage, was defined for Regions 1 B, 2A and 2B.

Checkerboard storage allows storage of the highest reactivity fuel in each region when checkerboarded with empty storage cells.

The McGuire spent fuel storage racks have been analyzed taking credit for soluble boron as allowed in Reference 3. The methodology ensures that the spent fuel rack multiplication factor, keff, is less than or equal to 0.95 as recommended in ANSI/ANS-57.2-1983 (Ref. 4) and NRC guidance (Ref. 5). The spent fuel storage racks are analyzed to allow storage of fuel assemblies with enrichments up to a maximum nominal enrichment of 4.75 weight percent Uranium-235 (maximum tolerance of +

0.05 wt.%) while maintaining ket< 0.95 including uncertainties, tolerances, bias, and credit for soluble boron. Soluble boron credit is used to offset uncertainties, tolerances, and off-normal conditions and to provide subcritical margin such that the spent fuel pool keff is maintained less than or equal to 0.95. The soluble boron concentration required to maintain keff less than or equal to 0.95 under normal conditions is 850 ppm. In addition, sub-criticality of the pool (keff < 1.0) is assured on a 95/95 basis, without the presence of the soluble boron in the pool. The criticality analysis performed shows that the acceptance criteria for criticality is met for the storage of fuel assemblies when credit is taken for reactivity depletion due to fuel burnup, the presence of Integral Fuel Burnable Absorber (IFBA) rods, reduced credit for the Boraflex neutron absorber panels and storage configurations and enrichment limits Specified by LCO 3.7.15.

I APPLICABLE SAFETY ANALYSES Most accident conditions do not result in an increase in reactivity of the racks in the spent fuel pool. Examples of these accident conditions are the drop of a fuel assembly on top of a rack, the drop of a fuel assembly between rack modules (rack design precludes this condition), and the drop of a fuel assembly between rack modules and the pool wall.

However, three accidents can be postulated which could result in an increase in reactivity in the spent fuel storage pools. The first is a drop or placement of a fuel assembly into the cask loading area. The second is a significant change in the spent fuel pool water temperature (either the loss of normal cooling to the spent fuel pool water which causes an increase in the pool water temperature or a large makeup to the pool with cold water which causes a decrease in the pool water temperature) and the third is the misloading of a fuel assembly into a location which the restrictions on location, enrichment, burnup and number of IFBA rods is not satisfied.

For an occurrence of these postulated accidents, the double contingency principle discussed in ANSI N-16.1-1975 and the April 1978 NRC letter McGuire Units 1 and 2 B 3.7.15-2 Revision No. 52

Spent Fuel Assembly Storage B 3.7.15 BASES APPLICABLE SAFETY ANALYSES (continued)

(Ref. 6) can be applied. This states that one is not required to assume two unlikely, independent, concurrent events to ensure protection against a criticality accident. Thus, for these postulated accident conditions, the presence of additional soluble boron in the spent fuel pool water (above the 850 ppm required to maintain kff less than or equal to 0.95 under normal conditions) can be assumed as a realistic initial condition since not assuming its presence would be a second unlikely event.

Calculations were performed to determine the amount of soluble boron required to offset the highest reactivity increase caused by either of these postulated accidents and to maintain kef less than or equal to 0.95. It was found that a spent fuel pool boron concentration of 1470 ppm was adequate to mitigate these postulated criticality related accidents and to maintain keff less than or equal to 0.95. Specification 3.7.14 ensures the spent fuel pool contains adequate dissolved boron to compensate for the increased reactivity caused by these postulated accidents.

Specification 4.3.1.1 c. requires that the spent fuel rack keff be less than or equal to 0.95 when flooded with water borated to 850 ppm. A spent fuel pool boron dilution analysis was performed which confirmed that sufficient time is available to detect and mitigate a dilution of the spent fuel pool before the 0.95 keff design basis is exceeded. The spent fuel pool boron dilution analysis concluded that an unplanned or inadvertent event which could result in the dilution of the spent fuel pool boron concentration to 850 ppm is not a credible event.

The configuration of fuel assemblies in the spent fuel pool satisfies Criterion 2 of 10 CFR 50.36 (Ref. 7).

LCO a

The restrictions on the placement of fuel assemblies within the Region 1 A of the spent fuel pool, which have a number of IFBA rods greater than or equal to the minimum qualifying number of IFBA rods in Table 3.7.15-1 or accumulated burnup greater than or equal to the minimum qualified burnups in Table 3.7.15-2 in the accompanying LCO, ensures the keff of the spent fuel pool will always remain < 0.95, assuming the pool to be flooded with water borated to 850 ppm. Fuel assemblies not meeting the criteria of Tables 3.7.15-1 or 3.7.15-2 shall be stored in accordance with Figure 3.7.15-1.

McGuire Units 1 and 2 B 3.7.15-3 Revision No. 52

Spent Fuel Assembly Storage B 3.7.15 BASES LCO (continued) b The restrictions on the placement of fuel assemblies within the Region 1 B of the spent fuel pool, which have accumulated burnup greater than or equal to the minimum qualified burnups in Table 3.7.15-4 in the accompanying LCO, ensures the kff of the spent fuel pool will always remain < 0.95, assuming the pool to be flooded with water borated to 850 ppm. Fuel assemblies not meeting the criteria of Table 3.7.15-4 shall be stored in accordance with either Figure 3.7.15-2 and Table 3.7.15-5 for Restricted storage, or Figure 3.7.15-3 for Checkerboard storage.

c The restrictions on the placement of fuel assemblies within the Region 2A of the spent fuel pool, which have accumulated burnup greater than or equal to the minimum qualified burnups in Table 3.7.15-7 in the accompanying LCO, ensures the keff of the spent fuel pool will always remain < 0.95, assuming the pool to be flooded with water borated to 850 ppm. Fuel assemblies not meeting the criteria of Table 3.7.15-7 shall be stored in accordance with either Figure 3.7.15-4 and Table 3.7.15-8 for Restricted storage, or Figure 3.7.15-5 for Checkerboard storage.

d The restrictions on the placement of fuel assemblies within the Region 2B of the spent fuel pool, which have accumulated burnup greater than or equal to the minimum qualified burnups in Table 3.7.15-10 in the accompanying LCO, ensures the kef of the spent fuel pool will always remain < 0.95, assuming the pool to be flooded with water borated to 850 ppm. Fuel assemblies not meeting the criteria of Table 3.7.15-10 shall be stored in accordance with either Figure 3.7.15-6 and Table 3.7.15-11 for Restricted storage, or Figure 3.7.15-7 for Checkerboard storage.

APPLICABILITY This LCO applies whenever any fuel assembly is stored in the spent fuel pool.

ACTIONS A.1 Required Action A.1 is modified by a Note indicating that LCO 3.0.3 does not apply.

When the configuration of fuel assemblies stored in the spent fuel pool is not in accordance with the LCO, the immediate action is to initiate action McGuire Units 1 and 2 B 3.7.15-4 Revision No. 52

Spent Fuel Assembly Storage B 3.7.15 BASES LCO (continued) to make the necessary fuel assembly movement(s) to bring the configuration into compliance.

If unable to move irradiated fuel assemblies while in MODE 5 or 6, LCO 3.0.3 would not be applicable. If unable to move irradiated fuel assemblies while in MODE 1, 2, 3, or 4, the action is independent of reactor operation. Therefore, inability to move fuel assemblies is not sufficient reason to require a reactor shutdown.

SURVEILLANCE SR 3.7.15.1 REQUIREMENTS This SR verifies by administrative means that the fuel assembly is in accordance with the configurations specified in the accompanying LCO.

REFERENCES

1.

UFSAR, Section 9.1.2.

2.

Issuance of Amendments, McGuire Nuclear Station, Units 1 and 2 (TAC NOS. MA9730 and MA9731), November 27,2000.

3.

WCAP-14416-NP-A, Westinghouse Spent Fuel Rack Criticality Analysis Methodology, Revision 1, November 1996.

4.

American Nuclear Society, "American National Standard Design Requirements for Light Water Reactor Fuel Storage Facilities at Nuclear Power Plants," ANSI/ANS-57.2-1983, October 7,1983.

5.

Nuclear Regulatory Commission, Memorandum to Timothy Collins from Laurence Kopp, "Guidance on the Regulatory Requirements for Criticality Analysis of Fuel Storage at Light Water Reactor Power Plants," August 19, 1998.

6.

Double contingency principle of ANSI N16.1-1975, as specified in the April 14,1978 NRC letter (Section 1.2) and implied in the proposed revision to Regulatory Guide 1.13 (Section 1.4, Appendix A).

7.

10 CFR 50.36, Technical Specifications, (c)(2)(ii).

McGuire Units 1 and 2 B 3.7.15-5 Revision No. 52

Progress Energy Docket o302 Operating license No. DPR-72 January 29, 2004 3F0104-10 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001

Subject:

Crystal River Unit 3 - Service List Update and Signature Authorization

Dear Sir:

The purpose of this correspondence is to inform the NRC of recent organizational changes at the Crystal River Unit 3 (CR-3) Nuclear Plant of Florida Power Corporation, doing business as Progress Energy Florida, Inc. These changes will affect the standard recipients of incoming NRC correspondence and those authorized to submit outgoing correspondence for CR-3.

CR-3 requests the following addition to the NRC Document Service List for CR-3:

Mr. Michael J. Annacone Engineering Manager Crystal River Nuclear Plant (NA2C) 15760 W. Power Line Street Crystal River, FL 34428-6708 e-Mail Address: Michael.Annacone@panmail.com In addition, CR-3 requests that the following listings be deleted from the NRC Document Service List for CR-3:

Mr. Donald L. Taylor Manager Support Services Crystal River Nuclear Plant (NA2C) 15760 W. Power Line Street Crystal River, FL 34428-6708 e-Mail Address: don.tavlor@vpnmai1.com Mr. James H. Terry Engineering Manager Crystal River Nuclear Plant (NA2C) 15760 W. Power Line Street Crystal River, FL 34428-6708 e-Mail Address: James.TerrvJr@pvnmail.com If you have any questions regarding this submittal, please contact Mr. Sid Powell, Supervisor, Licensing and Regulatory Programs at (352) 563-4883.

Sincerely, Dale E. Young Vice President Crystal River Nuclear Plant DEY/ff xc:

Regional Administrator, Region II Senior Resident Inspector Progress Energy Florida. Inc.

Crystal River Nuclear Plant 15760 W. Power line Street Crystal River. FL 34428 NRR Project Manager