ML16305A144
ML16305A144 | |
Person / Time | |
---|---|
Site: | McGuire, Mcguire |
Issue date: | 10/20/2016 |
From: | Duke Energy Carolinas |
To: | Document Control Desk, Office of Nuclear Reactor Regulation |
References | |
Download: ML16305A144 (17) | |
Text
Date: 10[20[201§ Distribution: Duke Energy Document Transmittal #: IR-NUC-MC-004375
- 1. Boyer, Robert P
Purpose:
~
- 2. Carroll, Michael E DOCUMENT TRANSMITTAL FORM
- 3. Gardner, Troy R Released By:
Facility: MCGUIRE NUCLEAR STATION Puke Energy
- 4. Mc Ginnis, Vickie L SUBJECT 13225 Hag~r!! E~rD Boi!d
- 5. OPS HUMAN PERFORMANCE -
Issue MNS Technical Sl!ecification 5.5 Document Mi!nagement
- 6. OPS TRNG MGR.
- 7. QATS- MG02DM B. RESIDENT NRC INSPECT Huntersville, NC 28078
- 9. SERV BLDG_FI~E ROOM~. MNSDCRM@guke-energy.com
- 10. U S NUC REG WASHINGTON, DC
- 11. USNRC
- 12. WESTINGHOUSE ELECTRIC CO LLC Page 1of1 Document ID 1 2 3 4 5 6 7 8 9 10 11 12 UCN - MC - MNS-TS-5.5 - 002 - ISSUED FYIIE FYIIE FYIIE FYIIE FYllE R&AIE FYllE PRINTILP FYIIE R&AIE R&AIE R&AIE
~
Remarks: RemoveLR~l!lai;;e IS 5.5
Programs and Manuals 5.5 5.0 ADMINISTRATIVE CONTROLS 5.5 Programs and Manuals The following programs shall be established, implemented, and maintained.
5.5.1 Offsite Dose Calculation Manual (ODCM)
The ODCM shall contain the methodology and parameters used in the calculation of offsite doses resulting from radioactive gaseous and liquid effluents, in the calculation of gaseous and liquid effluent monitoring alarm and trip setpoints, and in the conduct of the radiological environmental monitoring program.
Licensee initiated changes to the ODCM:
- a. Shall be documented and records of reviews performed shall be retained.
This documentation shall contain:
- 1. sufficient information to support the change(s) together with the appropriate analyses or evaluations justifying the change(s), and
- 2. a determination that the change(s) do not adversely impact the accuracy or reliability of effluent, dose, or setpoint calculations;
- b.
c.
Shall become effective after the approval of the Plant Manager or Radiation Protection Manager; and Shall be submitted to the NRC in the form of a complete, legible copy of the entire ODCM as a part of or concurrent with the Radioactive Effluent Release Report for the period of the report in which any change in the ODCM was made. Each change shall be identified by markings in the margin of the affected pages, clearly indicating the area of the page that was changed, and shall indicate the date (i.e., month and year) the change was implemented.
5.5.2 Containment Leakage Rate Testing Program A program shall be established to implement the leakage rate testing of the containment as required by 10 CFR 50.54(0) and 10 CFR 50, Appendix J, Option B, as modified by approved exemptions. This program shall be in accordance with the guidelines contained in Regulatory Guide 1.163, "Performance-Based Containment Leak-Test Program," dated September 1995, as modified by the following exceptions:
- a. NEI 94-01-1995, Section 9.2.3: The first Type A test performed after the October 21, 2008 (Unit 1) and March 31, 2008 (Unit 2) Type A test shall be performed no later than plant restart after the End Of Cycle 26 Refueling Outage (Unit 1) and no later than plant restart after the End Of Cycle 25 Refueling Outage (Unit 2), and McGuire Units 1 and 2 5.5-1 Amendment No. 290/269
Programs and Manuals 5.5 5.5 Programs and Manuals (continued)
- b. The containment visual examinations required by Regulatory Position C.3 shall be conducted 3 times every 10 years, including during each shutdown for SR 3.6.1.1 Type A test, prior to initiating the Type A test.
The peak calculated containment internal pressure for the design basis loss of coolant accident, Pa, is 14.8 psig. The containment design pressure is 15 psig.
The maximum allowable containment.leakage rate, La, at Pa, shall be 0.3% of containment air weight per day.
Leakage Rate acceptance criteria are:
- a. Containment leakage rate acceptance criterion is::;; 1.0 La. During the first plant startup following testing in accordance with this program, the leakage rate acceptance criteria are::;; 0.75 La for Type A tests and< 0.6 La for Type B and Type C tests.
- b. Airlock testing acceptance criteria for the overall airlock leakage rate is ::;
0.05 La when tested at ~Pa. For each door, the leakage rate is::; 0.01 La when tested at~ 14.8 psig.
The provisions of SR 3.0.3 are applicable to the Containment Leakage Rate Testing Program .
- 5.5.3 Nothing in these Technical Specifications shall be construed to modify the testing frequencies required by 10CFR50, Appendix J.
Primary Coolant Sources Outside Containment This program provides controls to minimize leakage from those portions of systems outside containment that could contain highly radioactive fluids during a serious transient or accident to levels as low as practicable. The systems include Containment Spray, Safety Injection, Chemical and Volume Control, Nuclear Sampling, RHR, Boron Recycle, Refueling Water, Liquid Waste, and Waste Gas.
The program shall include the following:
- a. Preventive maintenance and periodic visual inspection requirements; and
- b. Integrated leak test requirements for each system at refueling cycle intervals or less.
5.5.4 Deleted
- McGuire Units 1 and 2 5.5-2 Amendment No. 290/269
Programs and Manuals
- 5.5 Programs and Manuals (continued) 5.5.5 Radioactive Effluent Controls Program 5.5
- a. This program conforms to 10 CFR 50.36a for the control of radioactive effluents and for maintaining the doses to members of the public from radioactive effluents as low as reasonably achievable. The program shall be contained in Chapter 16 of the UFSAR, shall be implemented by procedures, and shall include remedial actions to be taken whenever the program limits are exceeded. The program shall include the following elements:
- 1. Limitations on the functional capability of radioactive liquid and gaseous monitoring instrumentation including surveillance tests and setpoint determination in accordance with the methodology in the ODCM;
- 2. Limitations on the concentrations of radioactive material released in liquid effluents to unrestricted areas, conforming to ten times 10 CFR 20, Part 20.1001 - 20.2401, Appendix B, Table 2, Column 2;
- 3. Monitoring, sampling, and analysis of radioactive liquid and gaseous effluents in accordance with 10 CFR 20.1302 and with
- 4.
the methodology and parameters in the ODCM; Limitations on the annual and quarterly doses or dose commitment to a member of the public from radioactive materials in liquid effluents released from each unit to unrestricted areas, conforming to 10 CFR 50, Appendix I;
- 5. Determination of cumulative and projected dose contributions from radioactive effluents for the current calendar quarter and current calendar year in accordance with the methodology and parameters in the ODCM at least every 31 days;
- 6. Limitations on the functional capability and use of the liquid and gaseous effluent treatment systems to ensure that appropriate portions of these systems are used to reduce releases of radioactivity when the projected doses in a period of 31 days would exceed 2% of the guidelines for the annual dose or dose commitment, conforming to 10 CFR 50, Appendix I;
- McGuire Units 1 and 2 5.5-3 (continued)
Amendment No. 184/166
Programs and Manuals 5.5 5.5 Programs and Manuals (continued) 5.5.5 Radioactive Effluent Controls Program (continued)
- 7. Limitations on the dose rate resulting from radioactive material released in gaseous effluents to areas beyond the site boundary shall be limited to the following:
- i. For noble gases: Less than or equal to a dose rate of 500 mrem/yr to the total body and less than or equal to a dose rate of 3000 mrem/yr to the skin, and ii. For iodine-131, iodine-133, tritium, and for all radionuclides in particulate form with half-lives greater than 8 days: Less
- than or equal to a dose rate of 1500 mrem/yr to any organ;
- 8. Limitations on the annual and quarterly air doses resulting from noble gases released in gaseous effluents from each unit to areas beyond the site boundary, conforming to 10 CFR 50, Appendix I;
- 9. a Limitations on the annual and quarterly doses to member of the public from iodine-131, iodine-133, tritium, and all radionuclides in particulate form with half lives > 8 days in gaseous effluents released from each unit to areas beyond the site boundary, conforming to 10 CFR 50, Appendix I;
- 10.
11.
Limitations on the annual dose or dose commitment to any member of the public due to releases of radioactivity and to radiation from uranium fuel cycle sources, conforming to 40 CFR 190; and Descriptions of the information that should be included in the Annual Radiological Environmental Operating, and Radioactive Effluent Release Reports required by Specification 5.6.2 and Specification 5.6.3.
- b. Licensee initiated changes to the Radiological Effluent Controls of the UFSAR:
- 1. Shall be documented and records of reviews performed shall be retained. This documentation shall contain:
- i. Sufficient information to support the change(s) together with the appropriate analyses or evaluations justifying the change(s), and
- McGuire Units 1 and 2 5.5-4 (continued)
Amendment No. 184/166
Programs and Manuals 5.5 5.5 Programs and Manuals (continued) 5.5.5 Radioactive Effluent Controls Program (continued) ii. A determination that the change(s) maintain the overall conformance of the solidified waste product to existing requirements of Federal, State, or other applicable regulations or a determination that the change will maintain the level of radioactive effluent control required by 10 CFR 20.1302, 40 CFR Part 190, 10 CFR 50.36a, and Appendix I to 10CFR Part 50 and not adversely impact the accuracy or reliability of effluent, dose, or setpoint calculations;
- 2. Shall become effective after approval of the station manager.
- 3. Shall be submitted to the Commission in the form of a complete, legible copy of the entire Section 16.11 of the UFSAR as a part of or concurrent with the Radioactive Effluent Release Report for the period of the report in which any changes to Section 16.11 of the UFSAR was made. Each change shall be identified by markings in the margin of the affected pages, clearly indicating the area of the page that was changed, and shall indicate the date (i.e.,
month/year) the change was implemented .
- 5.5.6 Component Cyclic or Transient Limit This program provides controls to track the UFSAR, Section 5.2.1.5, cyclic and transient occurrences to ensure that components are maintained within the design limits.
5.5.7 Reactor Coolant Pump Flywheel Inspection Program This program shall provide for the inspection of each reactor coolant pump flywheel per the recommendations of Regulatory Position C.4.b of Regulatory Guide 1.14, Revision 1, August 1975.
In lieu of Position C.4.b(1) and C.4.b(2), a qualified in-place UT examination over the volume from the inner bore of the flywheel to the circle one-half of the outer radius or a surface examination (MT and/or PT) of exposed surfaces of the removed flywheels may be conducted at 20 year intervals.
- McGuire Units 1 and 2 5.5-5 (continued)
Amendment No. 223/205
Programs and Manuals 5.5 5.5 Programs and Manuals (continued) 5.5.8 lnservice Testing Program This program provides controls for inservice testing of ASME Code Class 1, 2, and 3 components including applicable supports. The program shall include the following:
- a. Testing frequencies applicable to the ASME Code for Operation and Maintenance of Nuclear Power Plants (ASME OM Code) and applicable Addenda as follows:
ASME OM Code and applicable Required Frequencies for Addenda terminology for performing inservice testing inservice testing activities activities Weekly At least once per 7 days Monthly At Jeast once per 31 days Quarterly or every 3 months At least once per 92 days Semiannually or every 6 months At least once per 184 days Every 9 months . At least once per 276 days Yearly or annually At least once per 366 days I
Biennially or every 2 years At least once per 731 days
- b. The provisions of SR 3.0.2 are applicable to the above required Frequencies and to other JlOrmal and accelerated Frequencies specified as 2 years or less in the lnservice Testing Program for performing inservice testing activities;
- c. The provisions of SR 3.0.3 are applicable to inservice testing activities; and
5.5.9 Steam Generator (SG) Program A Steam Generator Program shall be established and implemented to ensure that SG tube integrity is maintained. In addition, the Steam Generator Program shall include the following:
- a. Provisions for condition monitoring assessments. Condition monitoring assessment means an evaluation of the "as found" condition of the tubing with respect to the performance criteria for structural integrity and accident induced leakage. The "as found" condition refers to the condition of the tubing during an SG inspection outage, as determined from the inservice inspection results or by other means, prior to the plugging of tubes. Condition monitoring assessments shall be conducted during each outage during which the SG tubes are inspected or plugged to confirm that the performance criteria are being met.
- McGuire Units 1 and 2 5.5-6 Amendment No. 284/263 (continued)
(
Programs and Manuals 5.5 5.5 Programs and Manuals (continued) 5.5.9 Steam Generator (SG) Program (continued)
- b. Performance criteria for SG tube integrity. SG tube integrity shall be maintained by meeting the performance criteria for tube structural integrity, accident induced leakage, and operational LEAKAGE.
- 1. Structural integrity performance criterion: All in-service steam generator tubes shall retain structural integrity over the full range of normal operating conditions (including startup, operation in the power range, hot standby, and cool down), all anticipated transients included in the design specification, and design basis accidents. This includes retaining a safety factor of 3.0 against burst under normal steady state full power operation primary-to-secondary pressure differential and a safety factor of 1.4 against burst applied to the design basis accident primary-to-secondary pressure differentials. Apart from the above requirements, additional loading conditions associated with the design basis accidents, or combination of accidents in accordance with the design and licensing basis, shall also be evaluated to determine if the associated loads contribute significantly to burst or collapse. In the assessment of tube integrity, those loads that do significantly affect burst or collapse shall be determined and assessed in combination with'the loads due to pressure with a
- safety factor of 1.2 on the combined primary loads and 1.0 on axial secondary loads ..
- 2. Accident induced leakage performance criterion: The primary to secondary accident induced leakage rate for any design basis accident, other than a SG tube rupture, shall not exceed the leakage rate assumed in the accident analysis in terms of total leakage rate for all SGs and leakage rate for an individual SG. Leakage is not to exceed 0.27 gallons per minute total.
- 3. The operational LEAKAGE performance criterion is specified in LCO 3.4.13, "RCS Operational LEAKAGE."
- c. Provisions for SG tube plugging criteria. Tubes found by inservice inspection to contain flaws with a depth equal to or exceeding 40% of the nominal tube wall thickness shall be plugged.
The number and portions of the tubes inspected and methods of inspection shall be performed with the objective of detecting flaws of any type (e.g., volumetric flaws, axial and circumferential cracks) that may be present along the length of the tube, from the 1*
- tube-to-tubesheet weld at the tube inlet to the tube-to-tubesheet weld at the tube outlet, and that may satisfy the applicable tube plugging criteria. The tube-to-tubesheet weld is not part of the tube. In addition to meeting the requirements of d.1, d.2, and d.3 below, the inspection scope, inspection methods, and inspection intervals shall be such as to ensure that SG tube integrity is maintained until the next SG inspection. A degradation assessment shall be performed to determine the type and location of flaws to which the tubes may be susceptible and, based on this assessment, to determine which inspection methods need to be employe~ and at what locations.
- McGuire Units 1 and 2 5.5-7 (continued)
Amendment No. 284/263
Programs and Manuals 5.5 5.5 Programs and Manuals (continued) 5.5.9 Steam Generator (SG) Program (continued)
- 1. Inspect 100% of the tubes in each SG during the first refueling outage following SG installation.
- 2. After the first refueling outage following SG installation, inspect each SG at least every 72 effective full power months or at least every third refueling outage (whichever results in more frequent inspections). In addition, the minimum number of tubes inspected at each scheduled inspection shall be the number of tubes in all SGs divided by the number of SG inspection outages schequled in each inspection period as defined in a, b, c, and d below. If a degradation assessment indicates the potential for a type of degradation to occur at a location not previously inspected with a technique capable of detecting this type of degradation at this location and that may satisfy the applicable tube plugging criteria, the minimum number of locations inspected with such a capable inspection technique during the remainder of the inspection period may be prorated. The fraction of locations to be inspected for this potential type of degradation at this location at the end of the inspection period shall be no less than the ratio of the number of times the SG is scheduled to be inspected in the inspection period after the determination that a new form of degradation could potentially be occurring at this location divided by the total number of times the SG is scheduled to be inspected in the inspection period. Each inspection period defined below may be extended up to 3 effective full power months to include a SG
- inspection outage in an inspection period and the subsequent inspection period begins at the conclusion of the included SG inspection outage.
- a. After the first refueling outage following SG installation, inspect 100% of the tubes during the next 144 effective full power months. This constitutes the first inspection period;
- b. During the next 120 effective full power months, inspect 100% of the tubes.
This constitutes the second inspections period;
- c. During the next 96 effective full power months, inspect 100% of the tubes. This constitutes the third inspection period; and
- d. During the remaining life of the SGs, inspect 100% of the tubes every 72 effective full power months. This constitutes the fourth and ~ubsequent inspection periods.
- 3. If crack indications are found in any SG tube, then the next inspection for each affected and potentially affected SG for the degradation mechanism that caused the crack indication shall not exceed 24 effective full power months or one refueling outage (whichever results in more frequent inspections). If definitive information, such as from examination of a pulled tube, diagnostic non-destructive testing, or engineering evaluation indicates that a crack-like indication is not associated with a crack(s), then the indication need not be treated as a crack.
- e. Provisions for monitoring operational primary to secondary LEAKAGE.
- McGuire Units 1 and 2 5.5-8 Amendment No. 284/263 (continued)
Programs and Manuals 5.5 5.5 Programs and Manuals (continued) 5.5.10 Secondary Water Chemistry Program This program provides controls for monitoring secondary water chemistry to inhibit SG tube degradation and low pressure turbine disc stress corrosion cracking .. The program shall include:
- a. Identification of a sampling schedule for the critical variables and control points for these variable~;
- b. Identification of the procedures used to measure the values of the critical variables;
- c. Identification of process sampling points, which shall include monitoring the discharge of the condensate pumps for evidence of condenser in leakage;
- d. Procedures for the recording and management of data;
- e. Procedures defining corrective actions for all off control point chemistry conditions; and
- f. A procedure identifying the authority responsible for the interpretation of the data and the sequence and timing of administrative events, which is required to initiate corrective action.
5.5.11 Ventilation Filter Testing Program (VFTP)
A program shall be established to implement the following required testing of Engineered Safety Feature (ESF) filter ventilation systems in accordance with Regulatory Guide 1.52, Revision 2, and ANSI N510-1975, with exceptions as noted in the UFSAR.
- a. Demonstrate for each of the ESF systems that an in place test of the high efficiency particulate air (HEPA) filters shows the following penetration*
and system bypass when tested in accordance with Regulatory Guide 1.52, Revision 2, and ANSI N510-1975 (N510-1980 for Auxiliary Building Filtered Exhaust) at the flowrate specified below +/- 10%.
- McGuire Units 1 and 2 5.5-9 (continued)
Amendment No. 237/219 J
Programs and Manuals 5.5 5.5 Programs and Manuals (continued) , .."
5.5.11 Ventilation Filter Testing Program (VFTP) (continued)
ESF Ventilation System Penetration Flowrate Annulus Ventilation < 1% 8000 cfm Control Area Ventilation < 0.05% 2000 cfm Aux. Bldg. Filtered Exhaust (2 fans)(Unit 1) < 1% 45,700 cfm Aux. Bldg. Filtered Exhaust (2 fans)(Unit 2) < 1% 40,500 cfm Containment Purge (non-ESF) (2 fans) < 1% 21,000 cfm Fuel Bldg. Ventilation (non-ESF) < 1% 35,000 cfm
- b. Demonstrate for each of the ESF systems that an in place test of the charcoal adsorber shows the following penetration and system bypass when tested in accordance with Regulatory Guide 1.52, Revision 2, and ANSI N510-1975 (N510-1980 for Auxiliary Building Filtered Exhaust) at the flowrate specified below +/- 10%.
ESF Ventilation System Penetration Flowrate Annulus Ventilation < 1% 8000 cfm Control Area Ventilation < 0.05% 2000 cfm Aux. Bldg. Filtered Exhaust (2 fans)(Unit 1) < 1% 45,700 cfm
- c.
Aux. Bldg. Filtered Exhaust (2 fans)(Unit 2)
Containment Purge (non-ESF) (2 fans)
Fuel Bldg. Ventilation (non-ESF)
< 1%
< 1%
< 1%
40,500 cfm 21,000 cfm 35,000 cfm Demonstrate for each of the ESF systems that a laboratory test of a sample of the charcoal adsorber, when obtained as described in Regulatory Guide 1.52, Revision 2, shows the methyl iodide penetration less than the value specified below when tested in accordance with ASTM D3803-1989 at the temperature and relative humidity (RH) specified below.
- ESF Ventilation System Penetration RH Temp.
Annulus Ventilation <4% 95% 30°C Control Area Ventilation < 0.95% 95% 30°C Aux. Bldg. Filtered Exhaust <4% 95% 30°C Containment Purge (non-ESF) <4% 95% 80°C Fuel Bldg. Ventilation (non-ESF) <4% 95% 80°C
- d. Demonstrate for each of the ESF systems that the pressure drop across the combined HEPA filters, the prefilters, and the charcoal adsorbers is less than the value specified below when tested in accordance with Regulatory Guide 1.52, Revision 2, and ANSI N510-1975 at the flowrate specified below +/- 10%.
(continued)
McGujre Units 1 and 2 5.5-10 Amendment No. 237/219
Programs and Manuals 5.5
- 5.5 Programs and Manuals 5.5.11 Ventilation Filter Testing Program (VFTP) (continued)
ESF Ventilation System Delta P Flowrate Annulus Ventilation 6.0 in wg .8000 cfm Control Area Ventilation 5.0 in wg 2000 cfm Aux. Bldg. Filtered Exhaust (2 fans)(Unit 1) 6.0 in wg 45,700 cfm Aux. Bldg. Filtered Exhaust (2 fans)(Unit 2) 6.0 in wg 40,500 cfm Containment Purge (non-ESF) (2 fans) 6.0 in wg 21,000 cfm Fuel Bldg. Ventilation (non-ESF) 6.0 in wg 35,000 cfm
- e. Demonstrate that the heaters for each of the ESF systems dissipate the value specified below when tested in accordance with ANSI N510-1975.
ESF Ventilation System Wattage@600 VAC Annulus Ventilation 43.0 .:!: 6.4 kW Control Area Ventilation 10.0 .:!: 1.0 kW The provisions of SR 3.0.2 and SR 3.0.3 are applicable to the VFTP test frequencies .
- 5.5.12 Explosive Gas and Storage Tank Radioactivity Monitoring Program This program provides controls for potentially explosive gas mixtures contained in the Waste Gas Holdup System, the quantity of radioactivity contained in gas storage tanks or fed into the offgas treatment system, and the quantity of radioactivity contained in unprotected outdoor liquid storage tanks. The gaseous radioactivity quantities shall be determined following the methodology in Branch Technical Position (BTP) ETSB 11-5, "Postulated Radioactive Release due to Waste Gas System Leak or Failure". The liquid radwaste quantities shall be determined in accordance with Standard Review Plan, Section 15.7.3, "Postulated Radioactive Release due to Tank Failures".
The program shall include:
- a. The limits for concentrations of hydrogen and oxygen in the Waste Gas Holdup System and a surveillance program to ensure the limits are maintained. Such limits shall be appropriate to the system's design criteria (i.e., whether or not the system is designed to withstand a hydrogen explosion);
- McGuire Units 1 and 2 5.5-11 Amendment No. 237/219 (continued)
Programs and Manuals 5.5
- 5.5 Programs and Manuals 5.5.12 Explosive Gas and Storage Tank Radioactivity Monitoring Program (continued)
- b. A surveillance program to ensure that the quantity of radioactivity contain~d in each gas storage tank or connected gas storage tanks and fed into the offgas treatment system is less than the amount that would result in a Deep Dose Equivalent of~ 0.5 rem to any individual in an unrestricted area, in the event of an uncontrolled release of the tanks' contents; and
- c. A surveillance program to ensure .that the quantity of radioactivity contained in all outdoor liquid radwaste tanks that are not surrounded by liners, dikes, or walls, capable of ~olding the tanks' contents and that do not have tank overflows and surrounding area drains connected to the Liquid Radwaste Treatment System is less than the amount that would result in concentrations exceeding the limits of 10 CFR 20, Appendix B, Table 2, Column 2, at the nearest potable water supply and the nearest surface water supply in an unrestricted area, in the event of an uncontrolled release of the tanks' contents.
The provisions of SR 3.0.2 and SR 3.0.3 are applicable to the Explosive Gas and Storage Tank Radioactivity Monitoring Program surveillance frequencies.
- 5.5.13 Diesel Fuel Oil Testing Program A diesel fuel oil testing program to implement required testing of both new fuel oil and stored fuel oil shall be established. The program shall include sampling and testing requirements, and acceptance criteria, all in accordance with applicable ASTM Standards. The purpose of the program is to establish the following:
- a. Acceptability of new,fuel oil for use prior to addition to storage tanks by determining that the fuel oil has:
- 1. an API gravity or an absolute specific grav.ity within limits,
- 2. a flash point and kinematic viscosity within limits for ASTM 2D fuel oil, and
- 3. a clear and bright appearance with proper color or a water and sediment content within limits;
- b. Other properties for ASTM 2D fuel oil are within limits within 31 days following sampling and addition to storage tanks; and (continued)
McGuire Units 1 and 2 5.5-12 Amendment No. 237/219
Programs and Manuals 5.5
- 5.5 Programs and Manuals 5.5.13 Diesel Fuel Oil Testing Program (continued)
- c. Total particulate concentration of the fuel oil is:;::; 10 mg/I when tested every 31 days.
- The provisions of SR 3.0.2 and SR 3.0.3 are applicable to the Diesel Fuel Oil Testing Program test frequencies.
5.5.14 Technical Specifications (TS) Bases Control Program This program provides a means for processing changes to the Bases of these Technical Specifications.
- a. Changes to the Bases of the TS shall be made under appropriate administrative controls and reviews.
- b. Licensees may make changes to Bases without prior NRC approval provided the changes do not require either of the following:
- 1. A change in the TS incorporated in the license; or
- 2. A change to the updated FSAR or Bases that requires NRC
- c.
d.
approval pursuant to 10 CFR 50. 59 .
The Bases Control Program shall contain provisions to ensure that the Bases are maintained consistent with the UFSAR.
Proposed changes that meet the criteria of Specification 5.5.14.b.1 or 5.5.14.b.2 above shall be reviewed and approved by the NRC prior to implementation. Changes to the Bases implemented without prior NRC approval shall be provided to the NRC on a frequency consistent with 10 CFR 50.71(e).
5.5.15 Safety Function Determination Program (SFDP)
This program ensures loss of safety function is detected and appropriate actions taken. Upon entry into LCO 3.0.6, an evaluation shall be made to determine if loss of safety function exists. Additionally, other appropriate actions may be taken as a result of the support system inoperability and corresponding exception to entering supported system Condition and Required Actions. This program implements the requirements of LCO 3.0.6. The SFDP shall contain the following:
(continued)
McGuire Units 1 and 2 5.5-13 Amendment No. 237/219
Programs and Manuals 5.5 5.5 Programs and Manuals 5.5.15Safety Function Determination Program CSFDP) (continued)
- a. Provisions for cross train checks to ensure a loss of the capability to perform the safety function assumed in the accident analysis does not go undetected;
- b. Provisions for ensuring the plant is maintained in a safe condition if a loss of function condition exists;
- c. Provisions to ensure that an inoperable supported system's Completion Time is not inappropriately extended as a result of multiple support system inoperabilities; and
- d. Other appropriate limitations and remedial or compensatory actions.
A loss of safety function exists when, assuming no concurrent single failure, a safety function assumed in the accident analysis cannot be performed. For the purpose of this program, a loss of safety function may exist when a support system is inoperable, and:
a.* A required system redundant to the system(s) supported by the inoperable support system is also inoperable; or
- b.
c.
A required system redundant to the system(s) in turn supported by the inoperable supported system is also inoperable; or A required system redundant to the support system(s) for the supported systems (a) and (b) above is also inoperable.
The SFDP identifies where a loss of safety function exists. If a loss of safety function is determined to exist by this program, the appropriate Conditions and Required Actions of the LCO in which the loss of safety function exists are required to be entered.
5.5.16 Control Room Envelope Habitability Program A Control Room Envelope (CRE) Habitability Program shall be established and implemented to ensure that CRE habitability is maintained such that, with an OPERABLE Control Room Area Ventilation System (CRAVS), CRE occupants can control the reactor safely under normal conditions and maintain it in a safe condition following a radiological event, hazardous chemical release, or a smoke challenge. The program shall ensure that adequate radiation protection is provided to permit access and occupancy of the CRE under design basis accident (OBA) conditions without personnel receiving radiation exposures in excess of 5 rem whole body or its equivalent to any part of the body for the duration of the accident. The program shall include the following elements:
(continued)
McGuire Units 1 and 2 5.5-14 Amendment No. 249/229
Programs and Manuals 5.5 5.5 Programs and Manuals 5.5.16 Control Room Envelope Habitability Program (continued)
- b. Requirements for maintaining the CRE boundary in its design condition including configuration control and preventive maintenance.
- c. Requirements for (i) determining the unfiltered air inleakage past the CRE boundary into the CRE in accordance with the testing methods and at the Frequencies specified in Sections C.1 and C.2 of Regulatory Guide 1.197, "Demonstrating Control Room Envelope Integrity at Nuclear Power Reactors," Revision 0, May 2003, and (ii) assessing CRE habitability at the Frequencies specified in Sections C.1 and C.2 of Regulatory Guide 1.197, Revision 0.
- d. Measurement, at designated locations, of the CRE pressure relative to atmospheric pressure during the pressurization mode of operation by one train of the CRAVS, operating at a makeup flow rate of.::_ 2200 cfm, at a Frequency of 18 months on a STAGGERED TEST BASIS. The results shall be trended and used as part of the periodic assessment of the CRE boundary in accordance with Regulatory Guide 1.197, Figure 1.
- e. The quantitative limits on unfiltered air inleakage into the CRE. These limits shall be stated in a manner to allow direct comparison to the unfiltered air inleakage measured by the testing described in paragraph c.
- The unfiltered air inleakage limit for radiological challenges is the inleakage flow rate assumed in the licensing basis analyses of OBA consequences. Unfiltered air in leakage limits for hazardous chemicals must ensure that exposure of CRE occupants to these hazards will be within the assumptions in the licensing basis.
- f. The provisions of SR 3.0.2 are applicable to the Frequencies for assessing CRE habitability, determining CRE unfiltered inleakage, and measuring CRE pressure and assessing the CRE boundary as required by paragraphs c and d, respectively.
- I 5.5.17 Surveillance Frequency Control Program This program provides controls for Surveillance Frequencies. The program shall ensure that Surveillance Requirements specified in the Technical Specifications are performed at intervals sufficient to assure the associated Limiting Conditions for Operation are met.
- a. The Surveillance Frequency Control Program shall contain a list of Frequencies of those Surveillance Requirements for which the Frequency is controlled by the program.
- b. Changes to the Frequencies listed in the Surveillance Frequency Control Program shall be made in accordance with NEI 04-10, "Risk-Informed Method for Control of Surveillance Frequencies," Revision 1.
- (continued)
McGuire Units 1 and 2 5.5-15 Amendment No. 261/241
Programs and Manuals 5.5 5.5 Programs and Manuals 5.5.17 Surveillance Frequency Control Program (continued)
- c. The provisions of Surveillance Requirements 3.0.2 and 3.0.3 are applicable to the Frequencies established in the Surveillance Frequency Control Program .
- McGuire Units 1 and 2 5.5-16 (continued)
Amendment No. 261/241