FINAL RO WRITTEN EXAMINATION FOR THE LASALLE INITIAL EXAMINATION - MAY 2003

ANSWER KEY RO NRC ILT WRITTEN EXAM 2003 LaSalle lnifial License Operator Examination REACTOR OPERATOR

Ro 201003 A2.10 Ro 3.0 SRo 3.4 High 2

SRO 3

Q#

BOTH Ability to (a) predict the impacts of the following on the CONTROL ROD AND DRIVE MECHANISM; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations:

Control Rod and DFive Mechanism Excessive SCRAM time for a given drive mechanism The scram time for control rod 22-43 is measured to be 90 seconds during single control rod scram timing.

(1) Predict how this will effect the rods response to a fill reactor scram and, (2) select the action taken to mitigate the consequences of those affects.

A. (1) The rod will fully insert, (2) recharge the accumulator per LOP-RD-20, Control Rod Accumulator Recharging B. (1) The rod will partially insert, (2) recharge the accumulator per LOP-RD-20, Control Rod Accumulator Recharging.

C. (1) The rod will fdly insert, (2) fully insert the control rod and disarm it IAW LOP-RD-12, Removal of a CRD HCU with Cooling Water On.

D. (1) The rod will partially insert (2) filly insert the control rod and disarm it IAW LOP-RD-12, Removal of a CRD HCU with Cooling Water On.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question D

T.S.3.1.3 and.3.1.4 024.00.14 New Difficulty:

PROVIDE REFERENCE Explanation:

Scram time requires the rod to be inserted per T.S.s. If the reactor scrammed, prior to rod insertion, the rod will only partially insert due to the SDV becoming hll.

2003 LaSalle Initial License Operator Examination REA C TO R 0 PERA TOR

Ro sRo Memory TIER GROUP RO 2

202001 Q#

BOTH 2

SRO 2

='01 3.2 3.2 Recirculation System Recirculation pumps: Plant-Specific Knowledge of electrical power supplies to the following:

Reactor Recirculation Pump 2A is powered fiom (1) when in FAST speed and (2) when in SLOW speed.

A.

(1) Bus 241Y (2) Bus 25 1 B. (1)Bus251 (2) Bus 241 Y C. (l)Bus251 (2) Bus 25 1 D. (1) Bus 241Y (2) Bus 24 1 Y ANSWER

Reference:

B LOP-RR-2AE Explanation:

Power supplies as stated.

Task / Objective:

Question Source:

Question 022.00.06 CPS ILTO 10 1 NRC Q#S 1 Difficulty:

2003 LaSalle lnitial License Operator Examination REACT0 R 0 PERA TO R

RO SRO High Q#

BOTH 2

Ro SRO 1

202002 K3.03 3.3 3.4 Knowledge of the effect that a loss or malfunction of the RECIRCULATION FLOW CONTROL SYSTEM will have on Recirculation Flow Control System following:

Reactor water level Unit 1 is at 100% power when a spurious trip of the 1A RR pump occurs.

INITIALLY, reactor water level will:

A, decrease, due to a decrease in core voids.

B. decrease, due to the RWLC system response on a trip of the RR pump.

C. increase, due to an increase in core voids.

D. increase, due, to the RWLC system response on a trip of the RR pump.

Task / Objective:

Question Source:

Question ANSWER:

Reference:

C LSCS-UFSAR 15.3-3 023.00.05 New Difficulty:

Explanation:

Reduction in core flow will initially cause an increase in core voids, resulting in an initial increase in reactor level.

2003 LaSalle lnitial License Operator Examination REACTOR OPERATOR

Ro 204000 K1.08 Ro 3,7 SRo 3.8 Memory 2

SRO 2

Q#

BOTH Knowledge of the physical connections and/or cause-effect relationships between REACTOR WATER CLEANUP SYSTEM and the following:

Reactor Water Cleanup System SBLC Which of the following describes the direct response of the Reactor Water Cleanup (RT) system when the Standby Liquid Control (SC) system is initiated?

A. The operating RT pumps trip when the SC pump starts.

B. The Outboard Isolation [ 1 (2)G33-F004] valve automatically closes.

C. The Blowdown Flow Control [ 1 (2)G33-F033] valve automatically closes.

D. The operating filter demineralizers go into HOLD when the SC pump starts.

ANSWER:

Reference:

Task I Objective:

Question Source:

Question B

LP-27 Section III.E, 027.00.12 Bank Difficulty:

1V.A Explanation:

The RT system isolates. The RT pumps will trip but NOT fiom a signal from the SC pump starting. The filter demineralizers do NOT go into HOLD on a signal from the SC pump starting. The Blowdown Flow Control valve does NOT close on a signal fiom the SC system initiating.

2003 LaSalle lnitial License Operator Examination REA CTO R 0 PERA TOR

Ro sRo High TIER GROUP RO 1

209001 2

SRO 1

3.0 3.1 Q#

BOTH Ability to predict and/or monitor changes in parameters associated with operating the LOW PRESSURE CORE SPRAY SYSTEM controls including:

Low Pressure Core Spray System Emergency generator loading An ECCS condition occurred on Unit 1. Normal power is available, but the operator decided to load the DG and manually close it onto Bus 141Y. Later, an ECCS and Undervoltage condition occurs on Unit 2.

What indication would you expect to see for the SAT feed to 14 1 Y and the 0 DG?

A. SAT feed to 141Y and 0 DG amps will remain constant.

B. SAT feed to 141Y amps will increase; 0 DG amps will decrease then immediately increase.

C. SAT feed to 141Y amps will increase and 0 DG amps will decrease.

D. SAT feed to 141Y amps will increase; 0 DG amps will decrease and then increase after a 5 second time delay.

ANSWER:

Reference:

Task I Objective:

Question Source:

Question A

LP Ch. 11 p. 50 063.00.05 New Difficulty:

Explanation:

Unless the U-1 breaker is manually tripped or the ECCS condition is reset, the closure permissives for the U-2 breaker CANNOT be met.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

TIER GROUP RO 1

209001 Ro SRo Memory 2

SRO 1

='03 2.9 3.1 Q#

BOTH Low Pressure Core Spray System Initiation logic Knowledge of electrical power supplies to the following:

The Unit 1 NSO arms and depresses the Division 1 and Division 2 ECCS initiation pushbuttons.

The LPCS pump does NOT start nor do any LPCS valves reposition as a result of hisher action.

The lack of LPCS system component response could be attributed to a loss of...

A. Bus l l l X B. Bus Illy C. Bus 112X D. Bus 112Y ANSWER:

Reference:

Task / Objective:

Question Source:

Question Difficulty:

B LP 63 p. 20 006.00.01 8 LaSalle 2000 ILT Certification Exam Q#30 Explanation:

LPCS is a Division 1 ECCS component. Logic for Division 1 ECCS, including LPCS, is from 1 1 IY.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

RO SRO High Q#

BOTH 2

Ro SRO 1

215004 K3.02 3.4 3.4 Knowledge of the effect that a loss or malfunction of the SOURCE RANGE MONITOR (SRM) SYSTEM will have on the following:

Source Range Monitoring System Reactor manual control: Plant Specific Reactor startup is in progress.

The reactor is NOT critical.

SRM's read as follows:

Channel:

A B

C D

Counts Per Second:

2x l O3 3x 10' 2x1 O3 5x1 O3 Predict the effect of a loss of the SRM C High Voltage Power Supply, AND what would be the necessary operator action?

EFFECT NECESSARY OPERATOR ACTION A.

RodBlock Suspend startup until repairs are completed.

B.

RodBlock Bypass the affected channel and continue startup.

C.

HalfScram Bypass the affected channel and continue startup.

D.

Halfscram Suspend startup until repairs are completed.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question B

LP 4 1,Section IV, 041.00.05 Modified, CPS ILTOlOl Difficulty:

LOA-NR-101, pp 9 Exam Explanation:

High Voltage Power Supply low creates INOP rod block, you are allowed to bypass and continue.

2003 LaSalle Initial License Operator Examination REACTOR OPERA TOR

Ro SRO 1

211000 A3.08 Ro 4.2 sRo 4.2 High 2

Q#

BOTH Ability to monitor automatic operations of the STANDBY LIQUID Standby Liquid System CONTROL SYSTEM including:

System initiation: Plant Specific The Standby Liquid Control (SBLC) system is in the following initial lineup:

Test Tank Outlet Valve (1 C4 1 -F03 1) is full open Head Tank Outlet Valve (lC41-FO14) is closed 1 A Storage Tank Outlet Valve (1 C4 1-F001 A) is closed 1B Storage Tank Outlet Valve (1 C4 1 -FOO 1B) is closed 1A SBLC Pump is OFF 1B SBLC Pump is OFF 1 A Squib Valve (1 C4 1-F004A) is closed 1B Squib Valve (lC41-FO04B) is closed If the 1A SBLC Pump keylock switch at 1H13-P603 were taken to SYS A, what would be the expected system status one (1) minute later?

A. The 1A SBLC system will remain in the current configuration.

B. The IA SBLC pump will be injecting test tank water into the reactor.

C. The 1A SBLC pump will be injecting both test tank AND storage tank volumes into the reactor.

D. The 1A SBLC squib valve will fre and all other components will remain in their current configuration.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question B

LP 28, p.12 of 35.

028.OO. 05 New Difficulty:

Explanation:

With the test tank outlet valve open, the suction valves will not open. The pump will start if either the test tank outlet valve is fully open or one of the storage tank outlet valves are hlly open. The squib valves fire anytime the keylock switch at 1H13-P603 it turned to SYS A.

2003 LaSalle Initial License Operator Examination REA C TO R 0 PERA TOR

Ro 214000 K6.02 Ro 2.7 sRo 2.7 High 2

SRO 2

Q#

BOTH Knowledge of the effect that a loss or malfunction of the following will have on the ROD POSITION INFORMATION SYSTEM:

Rod Position Information System Position indication probe Control Rod 38-13 is uncoupled.

The over-travel reed switch on control rod 38-1 3s position probe is stuck open.

Which of the following describes the expected indication on the Four-Rod Display if control rod 38-13 was withdrawn to position 48 and a coupling check then performed?

The position readout for Control Rod 38-13 on the Four Rod Display wi ll...

A. be blank and an OVERTRAVEL alarm will be received.

B. indicate a 48 and an OVERTRAVEL alarm will be received.

C. be blank and an OVERTRAVEL alarm will NOT be received.

D. indicate a 48 and an OVERTRAVEL alarm will NOT be received.

ANSWER:

Reference:

Task /Objective:

Question Source:

Question C

LOR 1 H13-P603-A402 024.00.05 Dresden 200 1 Difficulty:

LOA-RM-10 1 NRC/modified Explanation:

With the control rod uncoupled, the mechanism will settle to the over-travel position. With the over-travel reed switch stuck open, no alarm will be generated. There is no indication on the Four Rod Display when a control rod is in the over-travel beyond full-out position..

2003 LaSalle Initial License Operafor Examination REACTOR OPERATOR

Ro 215002 K3.01 Ro 3.3 sRo 3.5 Memory Q# 10 2

SRO 2

BOTH Knowledge of the effect that a loss or malfunction of the ROD BLOCK

. MONITOR SYSTEM will have on following:

Rod Block Monitor System Reactor manual control system: BWR-3,4,5 Unit 1 is at 100% power.

The function switch for the A RBM is placed in STANDBY What, if any, rod blocks will be applied?

A. Insert Block only.

B. Withdraw Block only.

C. Insert and Withdraw Block.

D. No rod blocks.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question B

LP 45 - RBM 45.00.05g New Difficulty:

pp 20 & 28 of 47; M

LOR 1 H 13-P603-A406 Explanation:

With RBM function switch NOT in operate, a RBM INOP trip exists, preventing rod movement. RBM only provides withdrawal blocks.

2003 LaSalle lnitial License Operator Examination REACTOR OPERATOR

Ro 215004 K5.01 Ro 2,6 SRo 2.6 Memory 2

SRO 1

Q# BOTH Source Range Monitor (SRM)

System Detector operation Knowledge of the operational implications of the following concepts as they apply to SOURCE RANGE MONITOR (SRM) SYSTEM:

Which of the following features of the Source Range Monitoring (SRM) system extends the detector effective lifetime?

A. The SRM detector can internal coating is enriched with U-234.

B. The SRM detector internal gas pressure is much greater than that used in either the Intermediate Range or Local Power Range Detectors.

C. The SRM detectors are physically larger than both the Intermediate Range and Local Power Range detectors.

D. The SRM detectors can be retracted from the core when the flux levels are high.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question D

LP 4 1 SRM system, 041.00.05 Bank, 041.00.05 004 Difficulty:

page 6 of 29 Explanation:

The SRM detectors are retracted from the core when NOT being used. All other choices are either incorrect statements, or statements that are true but do NOT add to SRM life extension.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro 217000 A3.06 Ro 3.5 SRo 3.4 Memory Q# 12 2

SRO 1

BOTH Reactor Core Isolation Cooling System (RCIC)

Lights and alarms Ability to monitor automatic operations of the REACTOR CORE ISOLATION COOLING SYSTEM (RCIC) including:

Two sets of position indicating lights are provided on Panel 1 H 13-P60 1 for the RCIC Turbine Trip and Throttle Valve, one on the vertical section and one on the horizontal section of the panel.

What condition is indicated if the lights on the vertical section indicate CLOSED and the indication on the horizontal section indicates OPEN?

The Trip and Throttle Valve...

A. is open with an initiation signal present.

B. was manually closed from the control room.

C. is closed due to a RCIC turbine trip.

D. is in a normal standby lineup.

Question ANSWER:

Reference:

Task / Objective:

Question Source:

C LP 32 Sect 1II.P 032.00.05 B

Difficulty:

Explanation:

A RCIC turbine trip signal would cause the valve to close, as would be indicated on the vertical section. The valve actuator, however, would still indicate open (horizontal section).

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro 217000 K4.05 Ro 3.2 SRo 3.5 Memory 2

SRO 1

Q# l 3 BOTH Knowledge of REACTOR CORE ISOLATION COOLMG SYSTEM (RCIC) design feature(s) and/or interlocks which provide for the Reactor Core Isolation Cooling System (RCIC) following:

Prevents radioactivity release to auxiliary/reactor building Which of the following correctly states four parameters that will cause an automatic PCIS isolation of the RCIC steam supply line (E5 1-FOOS)?

A.

B.

C.

D.

High RCIC Steam Flow Rate, High Temperature in the RCIC pipe tunnel, High Differential Temperature in the RCIC Pipe Tunnel, Low RCIC Steam Flow Rate.

High RCIC Steam Flow Rate, High Temperature in the RCIC equipment room, High Differential Temperature in the RCIC pipe tunnel, Low Steam Supply Pressure.

High Drywell Pressure, High Temperature in the RCIC equipment room, High Differential Temperature in the RCIC equipment room, Low Steam Supply pressure High Drywell Pressure, High Temperature in the RCIC equipment room, High Differential Temperature in the RCIC pipe tunnel, High Pressure between the rupture discs on the RCIC turbine exhaust line.

ANSWER:

Reference:

B LOP-PC-03 Task / Objective:

Question Source:

Question 032.00.05 Bank 032.00.12 003 Difficulty:

Explanation:

Answer B includes only RCIC isolation signals.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro 223002 A4.01 Ro 3.6 SRo 3.5 Memory Q# 14 2

SRO 1

BOTH Primary Containment Isolation SystemiNuclear Steam Supply Valve closures Ability to manually operate andor monitor in the control room:

Shut-Off Unit 2 is operating at rated conditions.

2A RPS and DC bus 21 1Y are both lost simultaneously.

Based on this loss, which of the following isolation valve(s) will close?

A. Inboard VP isolation valves B. Inboard MS isolation valves C. Outboard RI isolation valves D. Outboard W R isolation valves ANSWER:

Reference:

Task / Objective:

Question Source:

Question D

LOA-DC-20 1 p.44 and 091.00.05 DIP0 Bank Difficulty:

LOA-RP-201 p.6 Q# 1808 Explanation:

On loss of RPS A, Outboard PCIS valves for groups 1-3,5 and 10 close EXCEPT FOR MSIVs, PCCW and RBCCW. On loss of 2 1 1 Y, 2WR 179A 80 close.

2003 LaSalle lnitial License Operator Examination REACT0 R 0 PERA TOR

Ro sRo High 2

SRO 1

K6.10 3.3 3.5 TIER GROUP RO 2

226001 Q# l5 BOTH RHRLPCI: Containment Spray Knowledge of the effect that a loss or malfimction of the following will System Mode have on the RHWLPCI: CONTAINMENT SPRAY SYSTEM MODE:

Suppression chamber to drywell vacuum breakers: Mark-1-11 One of the suppression chamber to drywell vacuum breakers is found stuck open.

If a reactor water level instrument reference leg ruptured in the drywell, what affect would the vacuum breaker failure have on the use of the drywell and suppression chamber sprays compared to the same event with functional suppression chamber to drywell vacuum breakers?

With the suppression chamber to drywell vacuum breakers stuck open, would have to be placed in service earlier in the transient.

A. NEITHER the drywell sprays nor suppression chamber sprays B. ONLY the suppression chamber sprays C. ONLY the drywell sprays D. BOTH the drywell sprays and suppression chamber sprays ANSWER:

Reference:

D LP 090, p23 Task / Objective:

Question Source:

Question 064.00.05 New Difficulty:

Explanation:

With the vacuum breaker stuck open, the pressure suppression capacity of the containment would be reduced as steam would NOT be forced through the downcomers to be condensed by the suppression pool. Drywell and suppression chamber pressure would increase at a higher rate requiring alignment of the suppression chamber sprays and the drywell sprays at an earlier point in the transient.

2003 LaSalle Initial License Operator Examination REACTOR OPERA TOR

Ro 230000 A2.15 Ro 4.0 SRo 4.1 High Q# 16 2

SRO 2

BOTH Ability to (a) predict the impacts of the following on the RHWLPCI:

TORUS/SUPPRESSION POOL SPRAY MODE; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations:

RHRLPCI: Torus/Suppression Pool Spray Mode Loss of coolant accident Unit 2 was operating at rated conditions when one of the Recirculation pump suction lines completely separated from the vessel at the same time that all off-site power was lost.

The following conditions exist 60 seconds after the transient began:

0 0

0 Drywell pressure is 18 psig and increasing at 0.5 psiglminute Suppression chamber pressure is 16 psig and increasing at 0.5 psiglminute Reactor pressure is 300 psig and decreasing at 100 psiglminute Reactor water level is -1 7 1 inches and decreasing at 10 inches/minute Only the Division 2 DG started.

No operator action has yet been taken.

Regarding the B RHR suppression chamber spray valve, which of the following describes (1) the expected status of the valve, AND (2) the expected immediate operator actions regarding the valve?

The B RHR suppression chamber spray valve will be...

A. (1)OPEN.

(2) Operators will close the valve to increase vessel injection.

B. (1) OPEN.

(2) Operators will leave the valve open to control containment pressure.

C. (1) CLOSED.

(2) Operators will leave the valve closed to maximize vessel injection.

D. (1) CLOSED.

(2) Operators will open the valve to control containment pressure.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question LGA LP 07 - LGA-003 064.00.05 New Difficulty:

C 2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Explanation:

The suppression chamber spray valve will NOT automatically open on system initiation. With reactor vessel water level less than the top of active fuel, ECCS flow should NOT be diverted from vessel injection.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro 239002 A3.06 Ro 4.1 SRo 4.1 Memory Q# 17 2

SRO 1

BOTH RelieffSafety Valves Ability to monitor automatic operations of the RELIEFBAFETY VALVES including:

Reactor pressure A transient occurred that resulted in reactor pressure increasing to the Alternate Rod Insertion setpoint.

Which of the following indicates the MINIMUM number of safety relief valves that would be expected to have opened for this transient?

A. 7 B. 9

c. 1 1 D. 13 ANSWER:

Reference:

Task /Objective:

Question Source:

Question D

LP-70 p. 50 070.00.05 New Difficulty:

LOA-SRV-10 1 Explanation:

Actual setpoint is 1123 psig, which is greater than all of the SRV's relief setpoint.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro SRO 1

239002 K1.07 Ro 3,6 SRo 3.8 Memory 2

Q# l8 BOTH Knowledge of the physical connections andor cause-effect relationships between RELIEF/SAFETY VALVES and the following:

Relieusafety Valves Suppression pool SRV's discharge to the Suppression Pool at (1) elevation and (2) distances from the center of the Suppression Pool.

A. (1) the same (2) the same B. (1)varying (2) various C. (1)varying (2) the same D. (1) the same (2) various ANSWER:

Reference:

D LP 70 p.7 Task / Objective:

Question Source:

Question 070.00.05 N

Difficulty:

Explanation:

SRV's discharge near the bottom of the pool at varying distances from the center of the pool.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro 245000 K5.07 Ro 2.6 sRo 2.9 Memory 2

SRO 2

Q# l9 BOTH Knowledge of the operational implications of the following concepts as they apply to MAIN TURBINE GENERATOR AND AUXILIARY SYSTEMS:

Main Turbine Generator and Auxiliary Systems Generator operations and limitations Which of the following would occur if generator hydrogen pressure decreases to 25 psig while operating the main generator fully loaded?

Generator damage due to..

A. lack of cooling ability.

B. seal oil backup.

C. lack of seal oil.

D. hydrogen detonation.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question A

LP 009 p.30 009.00.05 New Difficulty:

Explanation:

Hydrogen pressure should be maintained within limits of generator loading.

1 2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro 259002 A1.02 Ro 3.6 SRo 3.5 High Q# 20 2

SRO 1

BOTH Ability to predict andor monitor changes in parameters associated with operating the REACTOR WATER LEVEL CONTROL SYSTEM controls including:

Reactor Water Level Control System Reactor feedwater flow The plant is operating normally at approximately 75% power.

The 1A and 1B TDRFP's are both in 3-Element control The RWLC setpoint is at 36 inches.

One of the MSL Flow inputs to RWLC instantaneously fails downscale.

Which of the following describes the expected response of reactor feedwater flow?

Reactor feedwater flow will....

A. remain constant.

B. initially increase and then decrease prior to an automatic scram.

C. initially decrease and then increase prior to an automatic main turbine trip.

D. decrease until the reactor automatically scrams due to low reactor water level.

ANSWER:

Reference:

Task I Objective:

Question Source:

Question A

LP 31 p. 50 03 1.00.05 Modified Difficulty:

2002R.bnk DFWOI 1 Explanation:

Failure of any single component will NOT impair the systems ability to maintain level.

2003 LaSalle lnitial License Operator Examination REACTOR OPERATOR

Ro 259002 K6.02 Ro 3.3 SRo 3.4 Memory Q# 21 2

SRO 1

BOTH Reactor Water Level Control System A.C. power Knowledge of the effect that a loss or malhnction of the following will have on the REACTOR WATER LEVEL CONTROL SYSTEM:

Unit 1 at 100% power.

1A and 1B TDRFP in 3-Element control.

A trip of 135X-3 occurs.

Which of the following describe how Reactor Water Level Control will respond to the event?

A. All RWLC M/A Stations will transfer to manual.

B. TDRFP's will transfer to Demand Substitution, the Feed Reg. Valve and Low Flow Feed Reg. Valve fail closed.

C. The RWLC system annunciates a minor RWLC failure alarm and component status is unchanged.

D. Band C Narrow range transmitters will fail downscale, causing a level 8 trip.

ANSWER:

Reference:

C LP 31 p. 44 Task / Objective:

Question Source:

Question 031.00.16 N

Difficulty:

Explanation:

335X-3 and 136X-3 provide redundant power supplies to 1H13-P660 & P612. On loss of 135X-3, power will be supplied from 136X-3.

2003, LaSalle Initial License Operator Examination REACTOR OPERATOR

RO SRO High 3.4 K1.04 3.1 Q# 22 TIER GROUP RO 2

262001 2

SRO 1

BOTH Knowledge of the physical connections and/or cause-effect relationships between A.C. ELECTRICAL DISTRIBUTION and the following:

A.C. Electrical Distribution Unintermptible power supply Unit 2 at 100% power LOR 2PMO1 J-A1 1 1, UPS TROUBLE alarm just received for the Process Computer UPS Computer Point R0256 UPS 480V Norm Sply Volt LO received.

The Unit 2 UPS is now fed fiom...

A. 235X-3 B. 135X-2

c. 221Y D. 211Y ANSWER:

Reference:

Task / Objective:

Question Source:

Question C

LOP-CX-02E;LP 12 p.

012.00.05 N

Difficulty:

17 Explanation:

Normal power supply is AC iom its own unit. The 250VDC supply backs up the normal. If both normal AC and backup DC are lost, alternate AC is supplied.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro sRo High Q# 23 TIER GROUP RO 2

262001 2

SRO 1

K2*01 3.3 3.6 BOTH A.C. Electrical Distribution Off-site sources of power Knowledge of electrical power supplies to the following:

Unit 1 has just started a refueling outage (shutdown was 3.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> ago).

Unit 2 is critical with a 65OFhour heat-up rate established.

Given this initial lineup, which one of the following combinations of failures would result in a loss of all Off-Site AC power to both units?

A. Unit 1 SAT and Lines 0 108 and 0 10 1.

B. Unit 1 SAT and Unit 2 SAT.

C. Unit 1 Ring Bus and Lines 0102 and 0103.

D. Unit-2 SAT and Lines 6102 and 0108.

ANSWER:

Reference:

Task / Objective:

Question' Source:

Question B

Figure 03-02 005.00.05 B

Difficulty:

Explanation:

With both generators off-line (UAT's are unavailable) a loss of both SAT'S will result in a loss of off-site power to both units.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

TIER GROUP Ro 263000 A4.02 Ro 3.2 SRo 3.1 Memory Q# 24 '

2 SRO 2

BOTH D.C. Electrical Distribution Battery voltage indicator: Plant-Specific Ability to manually operate andor monitor in the control room:

Unit 1, Division 1, 125VDC Voltage is indicated on the

'(1) panel and indicates (2)

A. (1) IPMOlJ (2) battery output only.

B.

(1) 1PMOlJ (2) battery and battery charger output.

C.

(1) IPM02J (2) battery output only.

D.

(1) lPM02J (2) battery and battery charger output.

ANSWER:

Reference:

B LP 6 p. 32 Task / Objective:

Question Source:

Question 006.00.07 N

Difficulty:

Explanation:

Battery and charger output indication are located on lPMOl J.

2003 LaSalle Initial License Operator Examination REACTOR 0 PERA TOR

Ro 264000 A2.04 Ro 2.9 sRo 3.0 High Q# 25 2

SRO 1 BOTH Ability to (a) predict the impacts of the following on the EMERGENCY GENERATORS (DIESEL/JET); and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations:

Emergency Generators (DieseVJet)

Consequences of operating underlover excited LOS-DG-M2, 1A/2A Diesel Generator Operability Test is in progress for the 1A Diesel Generator.

Current load is at 1300 KW with 180 KVARS.

Action should be taken to increase KVARS to (1) in order to (2)

A. (1)790out (2) maintain ECCS pump operability requirements should a loss of the SAT occur.

B. (1)790out (2) prevent the Diesel Generator 60m tripping on reverse power due to large load changes on the grid.

C. (1) 450 out (2) maintain ECCS pump operability requirements should a loss of the SAT occur.

D. (1)450 out (2) prevent the Diesel Generator from tripping on reverse power due to large load changes on the grid.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question D

LOS-DG-M2 p. 8 New Difficulty:

PROVIDE REFERENCE (TABLE ONLY)

Explanation:

D is the correct answer per LOS-DG-M2.

2003 LaSalle Mia/ License Operator Examination REACTOR OPERATOR

Ro 264000 K3.01 Ro 4.2 SRo 4.4 High Q# 26 2

SRO 1

BOTH Emergency Generators (DieseVJet)

Emergency core cooling systems Knowledge of the effect that a loss or malfbnction of the EMERGENCY GENERATORS (DIESEL/JET) will have on following:

Given the following Unit 1 conditions:

0 0

Drywell pressure at 2.0 psig.

The SAT has tripped due to spurious deluge.

One (1) minute later, the 1 A DG Cooling Water Pump trips.

If no operator action is taken, which of the following explains the operation of the emergency core cooling equipment?

A. Division 1 ECCS pumps will trip immediately due to a loss of power.

B. Division 2 ECCS pumps will trip immediately due to a loss of power.

C. Division 1 ECCS pumps will run until diesel failure occurs.

D. Division 2 ECCS pumps will run until diesel failure occurs.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question D

LOP-DG-01 p.5 01 1.00.05 New Difficulty:

Explanation :

The 1A DG high cooling water temperature trip is bypassed with a LOCA signal present. As a result, the 1A DG will eventually trip on high water temperature, which will deenergize bus 142, resulting in a loss of power to the Division 2 ECCS Pumps.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro 268000 K3.04 Ro 2.7 SRo 2.8 Memory 2

SRO 3

Q# 27 BOTH Radwas te Drain sumps Knowledge of the effect that a loss or malfunction of the RADWASTE will have on following:

2WEO lT, Unit 2 Waste Collector Tank is Out of Service and isolated.

1 WEOlT, Unit 1 Waste Collector Tank inlet valve (IWEOOl) solenoid has failed closed.

Input from which of the following will be affected by the above condition?

A. Reactor Building Equipment Drain Sumps B. Reactor Building Floor Drain Sumps C. Fuel Pool Filter Demin Backwash D.. Laundry Sample Tank ANSWER:

Reference:

Task I Objective:

Question Source:

Question 12 1.00.02 New Difficulty:

A LP 121 p. 68 Explanation:

A is the only input to the Waste Collector. All.other distracters are collected in other Radwaste Tanks.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro 268000 K5.02 Ro 3.1 SRo 3.6 High 2

SRO 3

Q# 28 BOTH Knowledge of the operational implications of the following concepts as they apply to RADWASTE:

Radwaste Radiation hazards and ALARA concept Which of the following individuals would have the greatest risk of exceeding their daily radiation exposure limit due to changing radiological conditions during the stated evolution?

An operator standing by the...

A. Spent Resin Tank (OWX03T) during a Unit 2 Reactor Water Clean-up System Filter Demineralizer Backwash.

B. Phase Separator Tank (2WXOlTB) during a Unit 2 Reactor Water Clean-up System Filter Demineralizer Backwash.

C. Spent Resin Tank (OWX03T) during a Unit 2 Condensate Polisher Resin Transfer To URC Inlet Vessel.

D. Phase Separator Tank (2WXO ITB) during a Unit 2 Condensate Polisher Resin Transfer To URC Inlet Vessel.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question B

LP 122, Waste 027.00.06 (location)

New Difficulty:

Processing System, Page 122.00.03.

5 of41 Explanation:

RWCU resin is highly irradiated with corrosion products from the RPV. The F/D is backwashed to the Phase Separator Tank. The CPs only have Condensate corrosion products, which are lower in dose than the RWCU resin and are sent to the URC, 2003 LaSalle Initial License Operator Examination REACT0 R OPERA TOR

Q# 29 BOTH 2

Ro SRO 2

271000 A1.08 Ro 3.,

SRo 3.1 High Offgas System System flow Ability to predict and/or monitor changes in parameters associated with operating the OFFGAS SYSTEM controls including:

Unit 1 is starting up.

Steam Jet Air Ejector steam flow is 65001bmh.

lN62-F30OA/B Main Condenser Outlet Valves are open with their C/S in OPEN.

What affect, if any, will placing the Control Switches for 1N62-F300A/B to AUTO have on Offgas system flow?

A. No affect.

B. Offgas flow will increase first, then return to its original value.

C. Offgas flow will increase.

D. Offgas flow will decrease.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question D

LOR lN62-P600-A505 080.00.05 New Difficulty:

Explanation:

At <7,800 Ibm/hr flow and the C/S in AUTO, the F300APB will close.

2003 LaSalle lnitial License Operator Examination REACTOR OPERATOR

Ro SRo High Q# 30 TIER GROUP RO 2

290001 2

SRO 1

A2*05 3.1 3.3 BOTH Ability to (a) predict the impacts of the following on the SECONDARY CONTAINMENT; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations:

Secondary Containment High area temperature Unit 1 is operating at 100% power.

A 2 gpm Reactor Water Cleanup leak has been identified in the 1A RT Pump Room.

Unit 1 Reactor Building Ventilation (VR) system spuriously trips.

Based on the above transient, (1) predict the concern of the VR Isolation on the secondary containment, AND (2) actions taken to mitigate the transient.

A. (1) Temperature increase affecting equipment operability; (2) Start ONE Standby Gas Treatment train to maintain area temperatures.

B. (1) Temperature increase affecting equipment operability; (2) Bypass high differential temperature isolation signals and restart VR.

C. (1) Radiation levels increasing, affecting equipment operability; (2) Bypass high radiation isolation signals and restart VR.

D. (1) Radiation levels increasing, affecting equipment operability; (2) Start BOTH Standby Gas Treatment trains to maintain area radiation levels.

ANSWER:

Reference:

Task I Objective:

Question Source:

Question B

LGA-002 Lesson Plan, 4 17.00.0 1 New Difficulty:

page 4 of 28 Explanation:

Area Temps. >2 12°F is an entry cond. for LGA-002. It's bases is to maintain emergency fimctions and ensure safety of personnel.

2003 LaSalle Initial License Operator Examination REACTOR 0 PEUA TOR

Ro SRo Memory TIER GROUP RO 2

290001 2

SRO 1

K4.03 2.8 2.9 Q# 31 BOTH Knowledge of SECONDARY CONTAINMENT design feature(s) andor interlocks which provide for the following:

Secondary Containment Fluid leakage collection What is the difference, if any, between how leakage into the reactor building comer room sumps will be processed during conditions in which the secondary containment has isolated as compared to normal operations?

A. NO DIFFERENCE, the floor drain sump will continue to pump down to the Radwaste floor drain collector tank regardless of secondary containment status.

B. The floor drain sump will isolate and need to be manually aligned to Radwaste floor drain collector tank using the RE/RF isolation bypass keylock switches at 1 (2)PM 16J.

C. The floor drain sump CANNOT be pumped down while the secondary containment is isolated, resulting in the sumps overflowing into the other comer room sumps.

D. The floor drain sump will be pumped to the reactor building equipment drain sump vice the Radwaste floor drain collector tank while the secondary containment is isolated.

ANSWER:

Reference:

Task I Objective:

Question Source:

Question A

LP 12 1, Liquid None.

New Difficulty:

Processing and Sumps, Section IKB, Page 8 of73 Explanation:

The reactor building floor drain sumps have no automatic isolation features associated with secondary containment isolation. The system will continue to operate normally.

2003 LaSalle Initial License Operator Examination REACTOR 0 PE RA TOR

Ro 290003 A3.01 Ro 3.3 sRo 3.5 High 2

SRO 2

Q# 32 BOTH Control Room HVAC Ability to monitor automatic operations of the CONTROL ROOM HVAC including:

Initiation/reconfiguration The OA Control Room Ventilation (VC) system is operating in purge mode to remove light smoke fi-om an electrical fault in a desktop computer.

Predict the response of the VC system if high radiation is detected in the outside air by detectors IDIX-K75 1 A and 1 D 18-K75 1 B?

A.

B.

C.

D.

ONLY VC Minimum and Maximum Outside Air Dampers will receive a signal to close. The VC Charcoal Filter will remain in its current lineup.

ONLY VC Minimum and Maximum Outside Air Dampers will receive a signal to close. The VC Charcoal Filter will realign.

VC and VE Minimum and Maximum Outside Air Dampers will receive a signal to close. The VC Charcoal Filter will remain in its current lineup.

VC and VE Minimum and Maximum Outside Air Dampers will receive a signal to close. The VC Charcoal Filter will realign.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question C

LOP-VC-01 rev. 19 p.64 I 17.00.05 Bank, LOP-VC-01 050 Difficulty:

Explanation:

The proper combination of rad monitors have tripped, so the system will realign to the pressurization mode.

When in the purge mode, the Odor Eater is placed in service, therefore it will NOT realign. On a high rad condition, the Emergency M/U will start. All min and max outside air dampers will close.

2003 LaSalle Initial license Operator Examination REACTOR OPERATOR

Ro SRo Memory TIER GROUP RO 2

290003 2

SRO 2

K4'01 3.1 3.2 Q# 33 BOTH Knowledge of CONTROL ROOM HVAC design feature(s) and/or interlocks which provide for the following:

Control Room HVAC System initiationsheconfiguration: Plant-Specific The Control Room Ventilation System is aligned for normal operations (NOT in purge) and smoke is detected in the RETURN AIR supply duct.

Which of the following describes the response of the VC System?

A. The VC Charcoal Filter is automatically placed on line and the Minimum Outside Air Damper closes.

B. The Emergency Make Up Train automatically comes on line and the Outside Air Supply isolates.

C. The VC Charcoal Filter is automatically placed on line and the Minimum Outside Air Damper remains open.

D. The Emergency Make Up Train automatically comes on line and the Minimum Outside Air Damper remains open.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question C

vc LP, pg. 4, 5 117.00.08 LaSalle 1999 NRC Difficulty:

Exam Explanation:

High return air smoke detection sensed upstream of the VC return fan suction isolation dampers aligns the VC System recirculation charcoal filter dampers to insure smoke removal. The alignment is as follows:

OVC 1 1 YA(B), Inlet, OPENS; OVC I2YA(B), Outlet, OPENS; OVC 13YA(B), Bypass, CLOSES.

EMU comes on line when smoke is detected in outside air supply NOT return air.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro 295003 2.1.28 Ro 3.2 sRo 3.3 Memory 1

SRO 1

Q# 34 BOTH Partial or Complete Loss of A.C.

Power Knowledge of the purpose and hnction of major system components and controls.

Conduct of Operations Unit 1 is at rated power with a normal electrical lineup.

If Bus 141Y voltage drops to 65% of its normal voltage...

A. the UAT feed to 14 1 Y will trip and the 0 DG will start and pick up the bus to restore voltage to essential equipment.

B. the UAT feed to 14 1 Y will trip and the SAT feed will automatically close to restore voltage to all loads on the bus.

C. the SAT feed to 14 1Y will trip and the 0 DG will start and pick up the bus to restore voltage to essential equipment.

D. the SAT feed to 141Y will trip and the UAT feed will automatically close to restore voltage to all loads on the bus.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question C

LOR-1 PMO I J-A3 14 005.00.10 LaSalle 1999 NRC Difficulty:

Exam Explanation:

If Bus 141Y voltage <69%, ACBs 1412 will trip, the 0 DG will start and ACB 1413 will close. The normal electrical power supply to 141Y is the SAT. The under voltage signal will also trip multiple non-essential loads.

c 2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro 295003 AK3.06 Ro 3.7 sRo 3.7 Memory Q# 35 1

SRO 1

BOTH Partial or Complete Loss of A.C.

Power Containment isolation Knowledge of the reasons for the following responses as they apply to PARTIAL OR COMPLETE LOSS OF A.C. POWER:

Why are Inboard and Outboard Primary Containment Isolation Valves powered fi-om separate sources?

(2)

To ensure that a loss or failure of (1) power supply(s) will A. (1) a single (2) NOT prevent an isolation from occurring.

B. (1) both (2) NOT prevent an isolation f?om occurring.

C. (1) a single (2) always result in an isolation.

D.

(1) both (2) always result in an isolation.

ANSWER:

Reference:

Task I Objective:

Question Source:

Question A

LP 09 1, PCIS 091.00.01 New Difficulty:

Page 3 of 5 1 Explanat ion:

The power supply arrangement is such that a failure of a single power supply will not prevent an isolation from occurring.

2003 LaSalle lnitial License Operator Examination REACTOR OPERATOR

Ro SRO 2

295004 AK3.02 Ro 2.9 sRo 3.3 Memory 1

Q# 36 BOTH Partial or Complete Loss of D.C.

Power Ground isolatiodfault determination Knowledge of the reasons for the following responses as they apply to PARTIAL OR COMPLETE LOSS OF D.C. POWER:

The following alarms are received in the control room:

0 0

125VDC Pnl 11 IX/Y Gnd Det 125VDC Div 1 Charger Trouble The Shift Manager has given permission to commence ground isolation on Bus 1 11Y per the appropriate procedure.

Which of the following indicates the system affected and the expected response of that system to opening individual circuit breakers during the course of ground isolation?

A. The "B' Narrow Range bdicator will fail downscale.

B. The 1A TDRFP will NOT respond to speed demand signals.

C. MDRFP will trip due to Level 8 trip.

D. RCIC will NOT automatically initiate as designed.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question D

LOA-DC-101 rev. 6 p.

06.00.18 LORT BANK Difficulty:

163 LOP-DC-04 002 Explanation:

RCIC auto initiation is prevented. B NR is NOT fed fiom 1 1 I Y. IA TDRFP is NOT fed fiom 1 1 1 Y and the C level 8 channel fails in a tripped condition, NOT preventing nor causing a trip by itself.

2003 LaSalle lnitial License Operator Examination REACTOR OPERATOR

Ro sRo Memory Ro 295005 AAl.01 3.1 3.3 Q# 37 1

SRO 2

BOTH Ability to operate and/or monitor the following as they apply to MAIN TURBINE GENERATOR TRIP:

Main Turbine Generator Trip Recirculation system: Plant-Specific Reactor power is at 60%, with a decreasing Relayed Emergency Trip Supply (RETS) pressure.

Which of the following describes the HIGHEST RETS pressure that will cause Reactor Recirculation (RR) pump speed to change and the expected final RR pump speed?

RETS Pressure RR Pumps A.

450 psig OFF B.

450 psig SLOW C.

550 psig OFF D.

550 psig SLOW ANSWER:

Reference:

Task / Objective:

Question Source:

Question B

LOR lH13-P603-B 106 07 1.00.10 New Difficulty:

Explanation:

With reactor power greater than 25% and RETS header pressure below 5 10 psig the EOC-RF'T downshift to slow speed interlock is activated and the RR pumps will automatically downshift.

2003 LaSalle Initial License Operator Examination REACTOR 0 PERA TOR

Ro 295005 AK1.03 Ro 3.5 SRo 3.7 High 1

SRO 2

Q# 38 BOTH Knowledge of the operational implications of the following concepts as they apply to MAIN TURBINE GENERATOR TRIP:

Main Turbine Generator Trip Pressure effects on reactor level Unit 2 is at rated conditions.

The 2A Moisture Separator Reheater Drain Tank level controls fail causing level to increase to the bottom of the 2A Moisture Separator Reheater Shell.

Which of the following describes the INITIAL response of reactor pressure and level to a Main Turbine Generator Trip from rated conditions?

Reactor Pressure will

[ 1) and INDICATED Reactor Water Level will (2)

A. (1) increase (2) increase B.

(1) increase (2) decrease C. (1) decrease (2) increase D. (1) decrease (2) decrease ANSWER:

Reference:

Task / Objective:

Question Source:

Question B

PBIG LGP 3-2, LP 07 1, 40.00.07 New Difficulty:

page 25 Explanation:

Reactor pressure will increase due to the loss of a major steam load and Reactor water level will decrease due to the pressure increase collapsing the voids and reduction in power.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

High RO SRO 3.9 Ro 295006 AKI.01 3.7 1

SRO 1 Q# 39 BOTH Knowledge of the operational implications of the following concepts as they apply to SCRAM:

SCRAM Decay heat generation and removal.

A reactor startup is in progress with reactor power at 13%.

An electrical malfunction causes all turbine control valves to open fi~lly.

The reactor automatically scrammed.

Without operator action, which of the following describes the methods of decay heat removal AVAILABLE immediately after the scram?

1.

Main Turbine Bypass Valves

2.
3.

Safety Relief Valves

4. Reactor Water Cleanup Outboard Main Steam Line Drains A.

1,2,3 and4 B. 1,2 and 3 only C. 2,3 and 4 only D. 3 and4only ANSWER:

Reference:

Task / Objective:

Question Source:

Question D

LOP-PC-03 p. 6&11 09 1.OO.OS N

Difficulty:

Explanation:

Control valves failing open would give a Group 1 (MSIV) isolation. Main Turbine Bypass Valves and outboard MSIV drains would NOT be available.

2003 LaSalle lnitial License Operator Examination REACTOR OPERATOR

Ro SRO

  • I 295007 AK1.02 Ro 3.1 SRo 3.4 High Q# 40 1

BOTH Knowledge of the operational implications of the following concepts as they apply to HIGH REACTOR PRESSURE:

High Reactor Pressure Decay heat generation Unit I is cooling down for a refueling outage with the following conditions present:

0 0

0 0

MSIV's are open 0

Reactor Pressure is 100 psig 1A RHR in Shutdown Cooling EHC pressure set is at 150 psig Reactor scram has been reset 0

All running RHR Service Water Pumps trip With no operator action, which of the following events will be expected to occur NEXT?

A. 1A RHR pump trip B. Turbine BPV's open C. MSIV's isolate D. Reactor Scram ANSWER:

Reference:

Task / Objective:

Question Source:

Question A

064, RHR System 064.00.21 New Difficulty:

Lesson Plan, IV.L.3.b, Page 34 of 59.

Explanation:

With a loss of RHR-WS, the vessel will heat up due to decay heat. When pressure reaches 135 psig, SDC will isolate, resulting in a low suction pressure trip of the 1 A RHR pump.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

1 Ro SRO I 1 295007 AK3.03 Ro 3.4 sRo 3.5 High Q# 41 BOTH Knowledge of the reasons for the following responses as they apply to HIGH REACTOR PRESSURE:

High Reactor Pressure RCIC operation: Plant-Specific RCIC flow is in automatic, injecting at rated flow.

SRV's are being cycled to maintain reactor pressure.

Which of the following describes the RCIC system FMAL parameters as reactor pressure rises from 800 to 1000 psig.

Turbine Sueed Pump Pump Discharge Flow Pressure A.

Lower Remain the Same Higher B.

Remain the Same Lower Lower C.

Higher Higher Remain the Same D.

Higher Remain the Same Higher ANSWER:

Reference:

D LP 32 p. 60 Task / Objective:

Question Source:

Question 032.00.05 LaSalle 2000 ILT Difficulty:

Certification Exam Explanation:

In AUTO, the system will attempt to maintain flow. As reactor pressure rises flow will lower and turbine speed and pump discharge pressure must be higher to maintain flow as described in LP 32.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro SRo Memory Ro 295008 AK1.02 2.8 2.8 Q# 42 I

SRO 2

BOTH Knowledge of the operational implications of the following concepts as they apply to HIGH REACTOR WATER LEVEL:

High Reactor Water Level Component erosioddamage The MDRFP will trip at Level 8 to prevent damaging the....

1. Safety Relief Valves
2.

Main Turbine

3. Reactor Vessel Steam Separator
4. RCIC Turbine A. 1,2,3 and 4.

B.

1,2 and 3 only.

C. 2 and 4 only.

D.

1 and 2 only.

Question ANSWER:

Reference:

Task / Objective:

Question Source:

D LP 77 p. 27.1V.A.3 071.00.05 Modified from Dresden Difficulty:

2002 Explanation:

High level trip to protect SRV's from water-hammer and prevent carryover to turbine.. RCIC has its own level 8 trip.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro 295008 AK2.07 Ro 2.9 SRo 3.0 Memory Q# 43 1

SRO 2

BOTH Knowledge of the interrelations between HIGH REACTOR WATER LEVEL and the following:

High Reactor Water Level HPCS: Plant-Specific HPCS automatically starts and injects to the vessel.

Annunciators for Reactor Vessel Level 8 are received on 1 H 13-P60 1.

Which of the following statements is true?

A. HPCS injection valve will close and the Full Flow Test valve will open.

B. HPCS injection valve will close and the HPCS pump breaker will trip.

C. HPCS will continue to inject due to the High Drywell signal.

D. HPCS pump will continue to run and the Minimum Flow valve will open.

Question ANSWER:

Reference:

Task / Objective:

Question Source:

D LP61 p. 13& 14 061.00.05 Modified, Perry 1997 Difficulty:

ILT exam Explanation:

HPCS Injection valve automatically closes on Level 8, the pump continues to run and the min flow will open.

Other answers incorrect because HPCS does NOT continue to inject, the pump breaker does NOT trip, and the Full Flow Test valve does NOT auto open.

2003 LaSalle Initial License Operator Examination REACTOR OPERA TOR

Ro 295010 AKl.01 Ro 3.0 SRo 3.4 High Q# 44 I

SRO 1

BOTH High Drywell Pressure Knowledge of the operational implications of the following concepts as they apply to HIGH DRYWELL PRESSURE:

Downcomer submergence: Mark-I&II A LOCA is in progress on Unit 2.

Drywell pressure is 13 psig and increasing at O.lpsig/min.

Which of the following would indicate proper operation of Primary Containment?

A Suppression Chamber Pressure of...

A. 0 - 1 psig.

B. 4 - 5 psig.

C. 8 - 9psig.

D. 12 - 13 psig.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question C

LP 90 Pri. And Sec.

090.00.05 New Difficulty:

Cont. p.20 Explanation:

Once drywell pressure overcomes the static head in the downcomers, suppression chamber pressure will increase. It takes approx. 4-5 psid to overcome the static head.

2003 LaSalle Initial License Operator Examination REACTOR 0 PE RA TOR

Ro 295013 AJS2.01 Ro 3.6 sRo 3.7 Memory Q# 45 1

SRO 1

BOTH High Suppression Pool Temperature TEMPERATURE and the following:

Suppression pool cooling Knowledge of the interrelations between HIGH SUPPRESSION POOL Unit 2 is at full power 0

0 0

Suppression Pool (SP) Cooling is in operation Average pool temperature is increasing RCIC testing is in progress If SP temperature continues to rise, the unit is required to immediately stop RCIC testing if SP temperature exceeds (1) degrees F, or immediately place the reactor mode switch in SHUTDOWN if SP temperature exceeds (2) degrees F.

A. (1) 105 (2) 110 B. (1) 110 (2) 120 C. (1) 105 (2) 120 D. (1) 100 (2) 110 ANSWER:

Reference:

Task / Objective:

Question Source:

Quest ion A

Technical Specification 032.00.20 2002 NRC ILT EXAM Difficulty:

3.6.2.1 090.00.22 Explanation:

Answer A is correct per the references.

2003 LaSalle lnitial License Operator Examination REACTOR OPERATOR

RO SRO High Ro SRO 1

295014 AK2.05 4.0 4.1 1

Q 46 BOTH Knowledge of the interrelations between INADVERTENT Inadvertent Reactivity Addition REACTIVITY ADDITION the following:

Neutron monitoring system Unit 1 is at 100% power.

Extraction Steam to the 16A HP Heater has just been lost.

LOA-HD-10 1, Heater Drain System Trouble has been entered.

APRM AGAFs:

A: 0.972 B : 0.974 C : 1.030 D: 1.040 E : 0.974 F: 1.024 Core power should be determined via:

A. Power-to-Flow Map.

B. APRMs.

C. OD3.

D. RBM.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question C

LOA-HD-IO1 p.36-37 044.00.014 New Difficulty:

Explanation:

When AGAFs out of spec., OD3 should be used.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro SRo Memory Ro 295015 AA1.02 4.0 4.2 Q# 47 1

SRO 1

BOTH Incomplete SCRAM RPS Ability to operate andor monitor the following as they apply to INCOMPLETE SCRAM:

A reactor scram signal has been received with the following indications for the scram group lights:

Which of the following indicates the MINIMUM actions required to de-energize the remaining RPS scram group lights?

Depress the scram pushbutton(s).

A. A1 OR A2 B. AI AND A2 C. B1 OR B2 D. B1 AND B2 ANSWER:

Reference:

Task I Objective:

Question Source:

Quest ion A

APRM LP Ch. 49, p. 5, 044.00.05 New Difficulty:

13, 17 Explanation:

The scram group lights are arranged with the A lights on top and the B lights on bottom. Either A pushbutton will de-energize all group lights.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro SRO

  • 1 295015 AK3.01 Ro 3.4 SRo 3.7 Memory 1

Q# 48 BOTH Knowledge of the reasons for the following responses as they apply to INCOMPLETE SCRAM:

Incomplete SCRAM Bypassing rod insertion blocks During performance of LGA-NB-01, Alternate Rod Insert, Single Rod Insertion, the operator is directed to place the MODE SELECT switch in BYP for the Rod Worth Minimizer.

The above action bypasses...

A. rod insert blocks to allow inward rod motion.

B. the settle function to speed the rate of rod insertion.

C. the single notch function to speed the rate of rod insertion.

D. nuclear Instrumentation rod blocks to allow all rod motion.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question A

LGA-NB-01 Rev 6 pg.

045.00.05 LaSalle 1999 NRC Difficulty:

11 Exam Explanation:

Placing the MODE SELECT switch in BYP will bypass the Rod Worth Minimizer bypassing all insert rod blocks. Response D is incorrect because rod withdraw blocks could still be generated by nuclear instrumentation. The RWM has no impact on the settle or single notch functions (of RMCS).

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro 295016 AA1.05 Ro 2.8 sRo 2.9 Memory 1

SRO I

Q# 49 BOTH Ability to operate and/or monitor the following as they apply to CONTROL ROOM ABANDONMENT:

Control Room Abandonment D.C. electrical distribution A fire in the Control Room has forced evacuation and control has been transferred to the Remote Shutdown panel.

Which of the following would indicate a loss of 121Y?

A. No position indication for K SRV.

B. B RHR flow indication downscale.

C. RCIC turbine trip and throttle valve indication.

a.

RHR Service Water flow indication downscale.

ANSWER:

Reference:

Task 1 Objective:

Question Source:

Question C

LOP-RI-0 1 E 032.00.05 New Difficulty:

Explanation:

RCIC is the only system listed that is affected by loss of 121Y.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Q# 50 BOTH TIER 1

High Off-Site Release Rate Off-gas system GROUP RO 2

SRO 1

295017 Ro sRo Memory AA1.02 3.5 3.7 Ability to operate and/or monitor the following as they apply to HIGH OFF-SITE RELEASE RATE:

Unit 1 is at 100% power.

Off-Gas Charcoal Adsorber Train Mode Switch in AUTO with the following lineup:

0 0

0 lN62-FO43, Off Gas Charcoal Adsorber Bypass Valve is open.

1N62-FO42, Off Gas Charcoal Adsorber Inlet Valve is closed.

lN62-FO57 Off Gas System Discharge to Stack is open 1N62-F085A/B Holdup Line Drain Valve are open What is the expected response of the Off Gas System to a valid Hi-Hi Post Treatment radiation condition?

A. No Off Gas Valves will auto position until a Hi-Hi-HI Rad signal is reached.

B. IN62-FO43 will close and lN62-FO42 will open.

C. lN62-FO43 will close; lN62-FO42 will open and 1N62-FO57 will close.

D. lN62-FO43 will close; 1N62-FO42 will open, lN62-FO57 will close and lN62-F085A/B will close.

ANSWER

Reference:

Task / Objective:

Question Source:

Question B

LOR lN62-P600-B207, 080.00.05 New Difficulty:

OFF GAS POST-TRMT RAD HI Explanation:

C and D do NOT occur until Hi-Hi-Hi setpoint is reached. A is incorrect because the Charcoal Adsorber Inlet and Bypass reposition.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro sRo Higher Ro 295017 AA1.09 3.6 3.8 1

SRO I

Q# 5 1 BOTH Ability to operate andor monitor the following as they apply to HIGH OFF-SITE RELEASE RATE:

High Off-Site Release Rate Standby gas treatmentfFRVS To reduce containment pressure, operators are venting primary containment using standby gas treatment system (SBGT) post-accident in accordance with LGA-VQ-01, "Containment Vent."

Reactor plant conditions are stable. Other plant conditions are as follows:

0 0

-Unit 1 SBGT train is in operation

-Unit 2 SBGT train is in standby

-Radiation levels in primary containment are elevated

-Primary containment pressure is 1.5 psig, decreasing

-Primary containment temperature is 145 deg F, decreasing If the discharge rate through the Unit 1 SBGT radiation monitor causes annunciator 1 PM07J-A304, "SBGT WIDE RANGE GAS MONITOR TROUBLE" to alarm due to a high radiation release condition, the operator would be required to...

A. continue venting, no radiation release limits are imposed.

B. secure venting to prevent exceeding offsite release.

C. continue venting until General Emergency radiation limits are reached.

D. verify automatic shutdown of the Unit I SBGT.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question Bank Difficulty:

2002 NRC Exam B

LGA-VQ-01 427.00.01 Explanation:

The above alarm indicates that the ODCM release rates have been exceeded, which is not authorized per LGA-VQ-0 1 (Limitation D. I ) If this alarm is received, direction is provided to shutdown the VG train.

2003 LaSalle Initial License Operator Examination REA CTO R 0 PERA TOR

RO SRO High Ro 295020 AK3.03 3,2 3.2 Q# 52 1

SRO 2

BOTH Knowledge of the reasons for the following responses as they apply to INADVERTENT CONTAINMENT ISOLATION:

Inadvertent Containment Isolation Drywell/containment temperature response 1 1 1 Y has been lost.

How will this affect Unit 1 Drywell temperature?

Drywell temperature will (1) due to (2)

A. (1) increase (2) outboard isolation valves closing.

B.

(1) increase (2) inboard isolation valves closing.

C. (1) remain the same (2) outboard isolation valves failing as is.

D. (1) remain the same (2) inboard isolation valves failing as is ANSWER:

Reference:

Task / Objective:

Question Source:

Question A

LOA-DC-10 1 p. 40 006.00.05 New Difficulty:

Explanation:

Loss of 1 11Y will cause the VP outboard isolation valves to close, resulting in an increase in Drywell temp.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro 295023 AK2.02 Ro 2.9 sRo 3.2 Memory Q# 53 1

SRO 1

BOTH Refueling Accidents Knowledge of the interrelations between REFUELING ACCIDENTS and the following:

Fuel pool cooling and cleanup system Unit 2 is in REFUEL with fuel movements in progress.

0 0

While moving a fuel bundle from the reactor to the fitel pool, the bundle was dropped in the fuel pool.

Several Refuel.Floor ARM'S were received along with an isolation of VR.

Unnecessary personnel were evacuated fiom the rehel floor and reactor building.

Given the above conditions, what is the expected response of the Fuel Pool Cooling System?

A. No automatic actions.

B. Automatically isolates the Fuel Pool Cooling Demineralizer.

C. Automatically trips Fuel Pool Cooling Pumps and isolates system.

D. Automatically places the second Fuel Pool Cooling Filter Demineralizer in line.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question A

LP 29 p. 28-3 1 029.OO.05 New Difficulty:

Explanation:

No automatic actions occur in the FC system based on the given conditions..

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

1 Ro SRO 1

295026 EKl.01 Ro 3.0 SRo 3.4 High Q# 54 BOTH Knowledge of the operational implications of the following concepts as TEMPERATURE:

Suppression Hi* Water they apply to SUPPRESSION POOL HIGH WATER Temperature Pump NPSH Unit 1 has experienced a transient.

Suppression Pool Level is -1 5 feet.

Which of the following conditions could be expected to cause LPCS system damage? Provide LCA Fig NL Suppression Suppression Pressure (psig)

TemDerature (OF)

Chamber Pool A.

0 210 B.

5 215 C.

10 230 D.

15 245 ANSWER:

Reference:

Task /Objective:

Question Source:

A LGA Figure NL 4 13.00.04 New Explanation:

Only A will be above the LPCS NPSH limit.

Question Difficulty:

2003 LaSalle lnifial License Operator Examination REACTOR 0 PERA TOR

RO SRO High 3.8 Ro 295026 EK2.02 3.6 1

SRO 1

Q# 55 BOTH Suppression Pool High Water Temperature Suppression pool spray: Plant-Specific Knowledge of the interrelations between SUPPRESSION POOL HIGH WATER TEMPERATURE and the following:

Suppression Pool level:

-6 feet Suppression Chamber pressure:

15 psig Which of the following is the HIGHEST Suppression Pool temperature that Suppression Chamber Sprays can be started without concerns of pump damage?

A. 235°F B. 240°F C. 24YF D. 250°F ANSWER:

Reference:

Task / Objective:

Question Source:

Question B

LGA-003 4 13.00.04 New Difficulty:

Provide Figure NR Explanation:

Using Figure NR, RHR/LPCI NPSH Limit, Suppression Pool temperatures of 245°F and 250°F are in the shaded area for NPSH concerns. 240°F is in the shaded portion for pool levels between - I 3 feet and -18 feet.

And 235OF is NOT in any shaded area. Therefore, 240°F is the highest temperature for the given conditions, that NPSH requirements are met.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

RO SRO High 295028 EA1.04 3.9 4.0 TIER GROUP RO 2

1 SRO 2 Q#

BOTH Ability to operate andor monitor the following as they apply to HIGH DRYWLL TEMPERATURE:

High Drywell Temperature Drywell pressure Unit I Primary Containment Chillers A & C are off.

Unit 1 Primary Containment Chiller B trips.

Which below describes...

(1) the status of containment cooling, AND (2) the expected IMMEDIATE (within one minute) effect on Unit 1 Drywell pressure?

A. (1) All cooling is lost (2) Drywell pressure will rise.

B. (1) All cooling is lost (2) Drywell pressure will remain constant.

C. (1) Limited cooling is still maintained (2) Drywell pressure will rise.

D. (1) Limited cooling is still maintained (2) Drywell pressure will remain constant.

ANSWER:

Reference:

Task J Objective:

Question Source:

Question C

LP 96, page 16 of 56 096.00.05 NEW Dificulty:

Explanation:

When a chiller unit trips, the Holdup Tank will provide about 10 minutes of residual cooling. The drywell air temperature and pressure will slowly rise should remain steady while the Holdup Tank provides residual cooling.

2003 LaSalle Inifial License Operator Examination REACTOR OPERA TOR

Ro SRo Memory Ro 295029 EA1.04 3.4 3.5 1

SRO 2

Q# 57 BOTH High Suppression Pool Water Level SUPPRESSION POOL WATER LEVEL RCIC: Plant-Specific Ability to operate andor monitor the following as they apply to HIGH Unit 2 RCIC is in a normal standby lineup.

Leaking valves cause Suppression Pool Level to increase such that High Suppression Pool Water Level alarms are received on the 2H 13-P60 1 panel.

Which one of the following describes the response of the RClC system to this condition?

A. RCIC Suction from the Suppression Pool, 2E5 1-F03 1, will open and then RCIC Suction from the CY Tank, 2E5 I-FO 10, will close.

B. RCIC Suction from the CY Tank, 2E5 1 -FO IO, will close and then RCIC Suction from the Suppression Pool, 2E5 1-F03 1, will open.

C. RCIC suctions will remain in standby configuration until a low CY Tank level condition occurs at which time they will transfer with 2E5 1-F03 1, RCIC Suction from the Suppression Pool, opening and then 2E5 I-FO 10, Suction from the CY Tank, closing.

D. RCIC suctions will remain in standby configuration until a low CY Tank level condition occurs at which time they will transfer with 2E5 1-F010, Suction from the CY Tank, closing and then 2E5 1-F03 1, RCIC Suction fi-om the Suppression Pool, opening.

ANSWER:

Reference:

Task I Objective:

Question Source:

Question C

RCIC LP 032, page 38 & 032.00.05 INPO Bank 766 Difficulty:

39 of 69 Modified Explanation:

RCIC suctions will now only automatically swap on a low CY tank level.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Q# '*

BOTH 1

Ro SRO 1

295030 EA1.03 Ro 3.4 sRo 3.4 High Low Suppression Pool Water Level SUPPRESSION POOL WATER LEVEL:

HPCS: Plant-Specific Ability to operate andor monitor the following as they apply to LOW Unit 1 is shutdown with HPCS in standby.

Suppression pool water level is being lowered from normal level to -9 feet.

Predict the impact of this change on the High Pressure Core Spray (HPCS) discharge Line Pressure.

HPCS discharge line pressure will...

A. remain constant due to the water leg pump suction source.

B. remain constant due to the water leg pump check valve.

C. will decrease by 3-5 psig.

D. will decrease by 7-9 psig ANSWER:

Reference:

Task / Objective:

Question Source:

Question C

GP GFES Chapter 6, 4 13.00.04 New Difficulty:

Page 75 of 89 Explanation:

As the SP Level Decreases, the HPCS Water Leg Pump suction pressure will decrease. Pump discharge head is directly related to pump suction head. (Hp+uourPm a VOUTPOUT).

If suction head decreases, discharge head will decrease corresponding to that amount. Therefore, since there is -.44 psig/foot in a column of water, if water level drops by 8 feet, C is the correct answer.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

RO SRO High Ro 295031 EA2.01 4.6 4.6 1

SRO 1

Q# 59 BOTH Reactor Low Water Level Ability to determine andor interpret the following as they apply to REACTOR LOW WATER LEVEL:

Reactor water level Drywell Temperature 3 10°F.

Reactor Building Ventilation has isolated.

Area Coolers are NOT able to maintain Reactor Building Temperatures.

Reactor Building Temperature 180'F.

Reactor Vessel Pressure 90 psig.

Cooldown Rate has NOT exceeded 100'Fhour.

Which of the following is a usable, on-scale level reading?

A. Shutdown Range level indication reading +80 inches.

B. Upset Range level indication +2 inches.

C. Narrow Range level indication reading +3 inches.

D. Fuel Zone level indication reading -3 10 inches.

ANSWER.

Reference:

Task 1 Objective:

Question Source:

Question D

LGA-001, Ref. K.

400.00.02 ILT Bank LGA-00 1 00 1 Difficulty:

Explanation:

D is correct because FZ level is indicating >-3 1 1 inches which is the minimum usable level with Reactor Building Temp< 200 degrees. S/D level can't be used because 80 is less than minimum usable level (85) with DW temp. 300-399 degrees. Upset level can't be used because it's less than minimum (84) for DW temp 300-399 degrees. NR can't be used because it's min level is +10 inches with Reactor Building Temp >150 degrees and DW temp. 300-399 degrees.

2003 LaSalle lnifial License Operafor Examination REACTOR OPERATOR

Ro 295032 EK3.03 Ro 3.8 sRo 3.9 High 1

SRO 2

Q#

BOTH High Secondary Containment Area Temperature Isolating affected systems Knowledge of the reasons for the following responses as they apply to HIGH SECONDARY CONTAINMENT AREA TEMPERATURE:

Unit 1 at 100% power.

Alarm 1 H 13-P60 1 -D507, RCIC PIPE RTE EQUIP AREA TEMP HI received.

Actions should be taken to (1) the RCIC pipe route area in order to maintain (2)

A.

(1) isolate any discharges into, (2) RCIC operability.

B. (1) isolate any discharges into, (2) equipment and access to areas needed for safe S/D.

C.

(1) monitor temperatures until Max Safe Level is reached, (2) RCIC operability.

D.

(1) monitor temperatures until Max Safe Level is reached, (2) equipment and access to areas needed for safe S/D.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question B

LGA-002: LGA LP 6 418.00.02 N

Difficulty:

p.2 4 Explanat ion:

Valid temperature places you in LGA-002 and requires you to isolate the affected discharge. Areas are monitored for equipment needed for safe S/D.

2003 LaSalle lnitial License Operator Examination REACTOR OPERATOR

Ro sRo Memory Ro

  • 295033 EK1.02 3.9 4.2 1

SRO 2

Q#

BOTH Knowledge of the operational implications of the following concepts as they apply to HIGH SECONDARY CONTAINMENT AREA RADIATION LEVELS:

High Secondary Containment Area Radiation Levels Personnel protection Unit I has experienced a LOCA.

LGA-004 has been performed ba d on the Pressure Supp Containment Pressure is at 52 psig and increasing.

ssion Pre sure limit being exceeded.

e LGA-VQ-02, Emergency Containment Vent has been directed.

Actions during the performance of this procedure should include...

A. shutdown of the Control Room Ventilation System.

B. shutdown of the Control Room Emergency Makeup train.

C. evacuation of the Reactor Building, Auxiliary Building, and Turbine Building in Unit 1 ONLY.

D. evacuation of the Reactor Building, Auxiliary Building, and Turbine Building in Unit 1 AND Unit 2.

ANSWER:

Reference:

Task / Objective:

Question Source:

Quest ion D

LGA-VQ-02, rev 9, page 4 13.00.02 New Difficulty:

7 of 74 Explanation:

D is correct due to the possible failure of ductwork in those areas during potentially contaminated venting at high pressures.

2003 LaSalle lnitial License Operator Examination REACTOR OPERATOR

High RO SRO 4.1 Ro 295037 EA1.03 4.1 1

SRO 1

Q# '*

BOTH SCRAM Condition Present and Reactor Power Above APRM Downscale or Unknown ARIRPTIATWS: Plant-Specific Ability to operate and/or monitor the following as they apply to SCRAM CONDITION PRESENT AND REACTOR POWER ABOVE APRM DOWNSCALE OR UNKNOWN:

Unit 1 was operating at 100% power when both RR pumps spuriously tripped.

0 0

RPS lights illuminated.

0 Rods did NOT move.

Reactor Scram pushbuttons for both divisions have been armed and depressed.

Mode Switch has been taken to SHUTDOWN.

APRM Downscale lights are extinguished.

The NEXT actions to be taken should be:

A. Initiate Alternate Rod Insertion.

B. Remove Scram solenoid fuses.

C. Maintain Reactor water level between + 1 1.O inches to +59.5 inches.

D. Maintain Reactor water level between -150 inches and +59.5 inches.

ANSWER:

Reference:

A LGA-0 10 Task / Objective:

Question Source:

Question 432.00.01 New Difficulty:

Explanation:

4 defines the next required action per LGA's. B is incorrect because ARI should be initiated first. C and D are NOT the next required actions and define an incorrect level band.

2003 LaSalle Initial License Operator Examination REACTOR 0 PERA TOR

Ro 295037 EK1.04 Ro 3.4 SRo 3.6 High I

SRO 1

BOTH Q# 63 SCRAM Condition Present and Reactor Power Above APRM Downscale or Unknown Hot shutdown boron weight: Plant-Specific Knowledge of the operational implications of the following concepts as they apply to SCRAM CONDITION PRESENT AND REACTOR POWER ABOVE APRM DOWNSCALE OR UNKNOWN:

An ATWS has occurred.

0 0

Only one quarter of the control rods are inserted.

RPV water level is being maintained between -120 and -80 inches.

Reactor pressure is being maintained between 900 and 1000 psig.

Hot Shutdown Boron Weight has just been injected.

Under which condition below would you expect the reactor to go critical again?

A. Cooldown of the reactor.

B. Placing RCIC in service to maintain vessel level.

C. Placing RWCU in service to stabilize reactor pressure.

D. Decay of xenon over the next several hours.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question A

LP 28, p.2: LP LGA-028.00.01 New Difficulty:

12(LGA-010 LP) p.34.

Explanation:

Hot Shutdown Boron Weight implies that the reactor should be subcritical at rated pressures and temperatures. A cooldown may only be commenced if Cold Shutdown Boron Weight has been injected.

RWCU may be utilized provided F/Ds are NOT used and it does NOT remove inventory.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro 300000 K6.03 Ro 2.7 SRo 2.7 High 2

SRO 2 Q#

BOTH Knowledge of the effect that a loss or malhnction of the following will have on the INSTRUMENT AIR SYSTEM:

Instrument Air System (IAS)

Temperature indicators Which of the following would have the greatest impact on Instrument Air system operation?

A station air compressor's...

A. lube oil temperature sensor failing low.

B. discharge air temperature sensor failing low.

C. air inlet differential pressure sensor failing high.

D. cooling water pressure sensor failing high.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question A

LP 120 plant air systems, 120.00.05a New DiMiculty:

page 4 of 34 Explanation:

Low or high lube oil temperature will trip the station air compressor. Discharge air temperature will trip the compressor but only if high. Air inlet dP failing high will result in a warning light but does NOT trip the compressor. Cooling water pressure sensor failing high will NOT trip the compressor.

2003 LaSalie initial License Operator Examination REACTOR OPERATOR

Ro SRo Memory Ro 600000 AK2.01 2.6 2.7 1

SRO 2

BOTH Q# 65 Plant Fire On Site Knowledge of the interrelations between PLANT FIRE ON SITE and the following:

Sensors, detectors and valves A fre in the 1 B Diesel Generator room has resulted in an automatic initiation of the C02 Flooding System.

The C02 system has NOT been reset, and the fire re-flashes.

Which of the following describes the actions and/or conditions required to re-actuate the system?

The C02 system activation....

A. will occur automatically once the detectors reach their setpoint for initiation again.

B. can be performed via the Local Initiation Pushbutton in the Diesel Generator corridor.

C. will only occur if the detectors are reset AND temperatures reach initiation setpoint.

D. can only be performed manually, via the local manual lever from the control panel in the Diesel Generator Corridor, AND will automatically terminate after 15 seconds.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question LP 125 -FP p. 22 125.00.06 New Difficulty:

B Explanation:

C02 system automatically initiates for a certain time. Operation after auto initiation may be done via local pushbutton or manually. If manually perfoimed, it must be manually secured.

2003 LaSalle Initial License Operator Examination REACTOR 0 PERA TOR

Ro GENERIC 2.1.11 Ro 3.0 sRo 3.8 High 3

SRO 1

Q#

BOTH Conduct of Operations Knowledge of less than one hour technical specification action statements for systems.

Unit I in MODE 2, withdrawing control rods.

0 All IRM's on range 2.

A11 SRM's are declared INOPERABLE.

Per Technical Specifications, operator action should include...

A. Suspend control rod withdrawal.

B. Fully insert all control rods.

C. Place the Mode Switch in SHUTDOWN.

D. Continue rod withdrawals as IRM operability is met.

ANSWER:

Reference:

Task I Objective:

Question Source:

Question A

T.S.3.3.1.2 041.00.016 New Difficulty:

Explanation:

With three required SRM's INOP in Mode 2 with IRM's on Range 2 or below, control rod withdrawal should be suspended immediately.

2003 LaSalle Initial License Operator Examination REACT0 R 0 PERA TOR

Ro GENERIC 2.1.9 Ro 2.5 sRo 4.0 Memory 3

SRO t

Q# 67 BOTH Conduct of Operations Ability to direct personnel activities inside the control room.

Which of the following tasks are responsibilities of a Reactor Operator per OP-AA-103-104, Reactivity Management Controls?

1.

Coordinate the conduct of refbeling activities and monitor nuclear instrumentation during refbeling activities that could affect the reactivity of the core.

2. Verify critical steps of Emergency Operating Procedure Flowcharts during transients and accident conditions.
3.

Ensure activities in the Control Room and plant are conducted in a professional manner, in accordance with approved procedures.

A. 1 and2ONLY

3.

2and3ONW C.

1 and3ONLY D. 1,2and3 ANSWER:

Reference:

Task / Objective:

Question Source:

Question C

OP-AA-103-104 755.020 N

Difficulty:

pp.3&4 Explanation:

2 is the NOT responsibility is NOT required of the Reactor Operator IAW OP-AA-103-104 2003 LaSalle lnitial License Operator Examination REACTOR OPERATOR

GROUP Ro GENERIC 2.2.12 Ro 3.0 SRo 3.4 Memory 3

SRO I

Q# 68 BOTH

. Equipment Control Knowledge of surveillance procedures.

Post maintenance testing of the RCIC system is required to be performed per LOS-RI-Q3, Reactor Core Isolation Cooling (RCIC) System Pump Operability and Valve Inservice Tests in Conditions 1,2, and 3.

Which of the following is required to be performed concurrent with the RCIC run?

A. Chemistry analysis on the Suppression Pool water.

B. Suppression Pool Temperature Monitoring Checks.

C. RCIC Monthly Valve Operability on the RCIC Exhaust Rupture Diaphragm.

D. Remote Shutdown Panel Post Accident Instrumentation Operability Checks.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question B

LOS-RI-Q3 Rev 3 1, 032.00.20 LaSalle 1999 NRC Difficulty:

page 6 of 49, D.3 Exam Explanation:

With RCIC System adding heat to the Suppression Pool, Suppression Pool temperatures must be verified less than or equal to 105'F at least once per 5 minutes and documented in LOS-AA-S101[201], Att G..

2003 LaSalle Initial License Operator Examination REACTOR OPERA TOR

Ro GENERIC 2.2.34 Ro 2.8 SRo 3.2 Memory 3

SRO 1

Q# 69 BOTH Equipment Control Knowledge of the process for determining the internal and external effects on core reactivity.

A Reactivity Maneuver (ReMa) Form is required for which of the following activities?

A. Withdrawing control rods for a reactor startup.

B. Inserting flow control line rods to clear APRM Hi alarms.

C. Opening RR Flow Control Valves to compensate for xenon buildup.

D. Closing RR Flow Control Valves to compensate for a heater drain transient.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question Page 10, B.7 and Bank LAP-100-13 005 Attachment H.

A LAP-100-13, Rev 25, 300.00.01 Modified, LORT Exam Difficulty:

Explanat ion:

'A' is required per LAP-100-1 3, Attachment H. Actions per LOA'S and LOR'S are permitted without the use of a ReMa, and a normal shutdown does not require a ReMa.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro GENERIC 2.3.2 Ro 2.5 SRo 2.9 Memory 3

SRO 1

Q# 70 BOTH Radiological Controls Knowledge of facility ALARA program.

Which of the following is the lowest level of authority authorized to waive Independent Verification of a valve position due to ALARA concerns?

A. Radiation Protection Shift Supervisor B. Reactor Operator C. Shifi Manager D. Plant Manager ANSWER:

Reference:

Task / Objective:

Question Source:

Question C

HU-AA;IOlp.7 NGET CPS ILTO 10 1 Difficulty:

Explanat ion:

Shift Manager may waive per HU-AA-I 0 1.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro GENERIC 2.3.9 Ro 2.5 sRo 3.4 High 3

SRO 1

Q# 7' BOTH Radiological Controls Knowledge of the process for performing a containment purge.

Which of the following must be in service prior to performing a containment purge when the unit is at power?

A. ONLY the MCR Emergency Makeup Train B. MCR AND AEER Emergency Makeup Trains C. ONLY the MCR Recirculation Charcoal Filter Unit D. MCR AND AEER Recirculation Charcoal Filter Units ANSWER:

Reference:

Task / Objective:

Question Source:

Question D

LOP-VQ-04, Rev 12, 93.00.20 LaSalle 1999 NRC Difficulty:

Sect D.3, Pg 8 of 5 1 Exam Explanation:

If the unit is in OC 1,2, or 3, BOTH MCR and AEER Recirculation Charcoal Filters are to be verified in service prior to purging the drywell.

2003 LaSalle lnitial License Operator Examination REACTOR OPERATOR

TIER GROUP Ro I

GENERIC 2.4.20 Ro 3.3 SRo 4.0 Memory Q# 72 3

SRO 1

BOTH Emergency Procedures and Plan Knowledge of operational implications of EOP warnings, cautions, and notes.

During a casualty, an NSO opens an SRV to control pressure. The SRV is closed and manually opened 15 seconds later.

Which of the following describes the potential adverse consequences of this action?

A. SRV tailpipe damage due to excessive water level in the tailpipe.

B. Suppression pool wall damage to the due to cyclic dynamic loading.

C. SRV seat damage due to partial opening of the valve with limited air pressure.

D. ECCS pump damage due to the creation of a vortex in the suppression pool.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question A

LGA-001 Lesson Plan 070.00.20 New Difficulty:

IV.D.4.a).6) page 12 of 34 Explanation:

Following the closure of an SRV, there is a certain amount of time require for the steam to condense in the tailpipe, the vacuum breaker in the tailpipe to open and the water level in the tailpipe to equalize with suppression pool level. Failure to allow the level to equalize could result in water hammer damage of the tailpipe.

2003 LaSalle lnitial License Operator Examination REACTOR OPERATOR

Ro GENERIC 2.4.35 Ro 3.3 sRo 3.5 Memory Q# 73 BOTH 3

SRO 1

Emergency Procedures and Plan Knowledge of local auxiliary operator tasks during emergency operations including system geography and system implications.

The Unit Supervisor has directed performance of LGA-NB-0 1, Venting CRD Withdrawal Line. In order to perform this task, the non-licensed operator will need a tygon hose, CRD vent valve wrenches, a crescent wrench and straps.

Tools and equipment required to perform this task are located in the...

A. Control Room LGA File Cabinet.

B. Reactor Building Supply Cabinet, 76 1 Reactor Building.

C. LGA Support Cabinet, 768 Turbine Building.

D. Main LGA Support Locker outside Unit 2 Aux. Electric Equip. room, 73 1 Aux. Building.

Task / Objective:

Question Source:

Question Modified ANSWER:

Reference:

D LGA-NB-01 p. 2 and 3.

2160.010 Dresden 2002 Difficulty:

Explanation:

D correctly states the location the equipment can be found.

2003 LaSalle Initial License Operator Examination REA CTO R OPERA TOR

RO SRO High Ro GENERIC 2.4.48 3.5 3,8 3

SRO 1

Q# 74 BOTH Emergency Procedures and Plan Ability to interpret control room indications to verify the status and operation of system, and understand how operator action s and directives affect plant and system conditions.

LGA-003, Primary Containment Control is in progress.

Suppression Chamber and Drywell Sprays are both on.

Drywell Pressure is 0.5 psig and decreasing at 0.25 psiglmin.

Suppression Chamber pressure is 0.9 psig and decreasing at 0.25 psiglmin.

Which of the following describes the actions that should be taken NEXT, AND the reason for that action?

A. Secure Drywell Sprays to prevent exceeding drywell floor limit.

B. Secure Drywell Sprays to prevent raising oxygen levels in the Drywell.

C. Secure Suppression Chamber Sprays to prevent exceeding drywell floor limit.

D. Secure Suppression Chamber Sprays to prevent raising oxygen levels in the Drywell.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question A

LGA Mod 007 - LGA-400.00.07 Modified, Dresden 1996 Difficulty:

003 LP, p. 11 ILT Exam Explanation:

Stopping sprays before 0 psig prevents negative pressure in the containment. This prevents exceeding design criteria of the drywell.

2003 LaSalle initial License Operator Examination REACTOR OPERATOR

Ro sRo Memory 3.1 4.0 Ro GENERIC 2.4.6 3

SRO 1

Q# 75 BOTH Emergency Procedures and Plan Knowledge symptom based EOP mitigation strategies.

Unit 2 is shutdown with the following conditions:

0 A large LOCA has occurred.

Containment pressure quickly exceeded the Pressure Suppression Pressure Limit.

Which of the following describes the sequence of steps to be attempted to mitigate the containment pressure increase?

A.

B.

C.

D.

Align RHR for Drywell Spray; Align RHR for Suppression Chamber Spray; Initiate ADS; Align VQ for venting the Drywell.

Align VQ for venting the Drywell; Align RHR for Suppression Chamber Spray; Align RHR for Drywell Spray; Initiate ADS.

Align RHR for Suppression Chamber Spray; Align RHR for Drywell Spray; Initiate ADS; Align VQ for venting the Drywell.

Align VQ for venting the Drywell; Align RHR for Drywell Spray; Align RHR for Suppression Chamber Spray; Initiate ADS.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question C

LGA-003 Rev 4 400.00.18 LaSalle I999 NRC Difficulty:

Exam Explanation:

Suppression chamber sprays are always attempted prior to DW sprays. ADS is always performed prior to venting per LGA-VQ-02. The initial venting of the containment to control pressure is LGA-VQ-0 1 and CANNOT be performed if VQ has isolated on high containment pressure.

2003 LaSalle lnitial License Operator Examination REACTOR OPERATOR

Q# 76 RO Ro 202002 A1.06 Ro 3.4 sRo 3.3 HIGH 2

SRO 1

Ability to predict and/or monitor changes in parameters associated with operating the RECIRCULATION FLOW CONTROL SYSTEM controls including:

Recirculation Flow Control System Reactor core flow Unit I is operating at 80% power with the A Recirculation loop HPUs locked up.

Which of the following describes:

(1) the response of the Recirculation system if a Flow Control Runback signal was received, AND (2) the potential consequences?

A.

(1) Only the B Flow Control Valve would partially close, reducing core flow.

(2) Increased chance of cyclic fatigue at the jet pump riser brace welds.

B.

(1) Only the B Flow Control Valve would partially close, reducing core flow.

(2) lncreased chance of cavitation erosion to the Flow Control Valve seating surface.

C.

(1) Neither Flow Control valve would reposition, core flow would remain constant.

(2) Increased chance of reactor scram during level transients.

D. (1) Neither Flow Conwol valve would reposition, core flow would remain constant.

(2) Increased chance of Recirculation pump trip during level transients.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question A

LOP-RR-07 p. 5 023.00.05 N

Difficulty:

Explanation:

In this arrangement a FCV runback could result in excessive flow differences. Operations with large flow mismatches in loop flows increases cyclical fatigue to component such as jet pp. riser brace welds.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Q# 77 RO Ro SRo High 2

SRO 2

K3-04 3.7 3.7 TIER GROUP RO 2

205000 Shutdown Cooling System (RHR Shutdown Cooling Mode)

Recirculation loop temperatures Knowledge of the effect that a loss or malfbnction of the SHUTDOWN COOLING SYSTEMMODE will have on following:

Unit 1 in Cold Shutdown.

0 B RHR in Shutdown Cooling with a suction temperature of 190°F.

A RHR pump is 00s.

Reactor Water level is 145 inches.

1A RR pump is in slow speed 1B RR Pump is 00s.

Which of the following describes the initial response of the Reactor Recirculation pump suction temperatures if the B RHR pump tripped?

1A RR Pump 1B RR Pump Suction Temperature Suction Temperature A.

Increase Remain Relatively Stable B.

Increase Increase C.

Remain Relatively Stable Increase D.

Remain Relatively Stable Remain Relatively Stable ANSWER:

Reference:

Task f Objective:

Question Source:

Question A

LOA-RH-10 1 p. 17 023.00.05 New Difficulty:

LOP-RH-07, p. 8 Explanation:

The 1A RR loop would warm up with the increasing RPV Temperature due to decay heat. The IB loop temperature should be at near drywell temperature and will remain relatively constant since its suction or discharge isolation valve is closed while in SDC to prevent short cycling the SDC flow, therefore there is no flow in that loop.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Q# 78 Ro Ro '

209002 K2.02 Ro 2.x SRo 2.9 Memory 2

SRO 1

High Pressure Core Spray System (HPCS)

Valve electrical power: BWR-5, 6

Knowledge of electrical power supplies to the following:

A loss of MCC 243-1 will prevent operation of which of the following components?

A. Unit 2 High Pressure Core Spray Injection Valve.

B. Unit 2 Low Pressure Core Spray Injection Valve.

C. Unit 2 Reactor Core Isolation Cooling Injection Valve.

D. Unit 2 "C" Residual Heat Removal Injection Valve.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question A

LOP-HP-0 1 E 061.00.. 16 New Difficulty:

Explanation:

243-1 supplies 2E22-FO04.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Q# 79 RO RO SRO High Ro 209002 K6.04 2.5 2.5 2

SRO 1

High Pressure Core Spray System (HPCS)

Suppression pool suction strainer: BWRJ, 6 Knowledge of the effect that a loss or malhnction of the following will have on the HIGH PRESSURE CORE SPRAY SYSTEM WPCS):

HPCS is running in Full Flow Test lineup LAW LOS-HP-Q1, HPCS SYSTEM INSERVICE TEST.

HPCS Flow cycling between 1000 and 6000 gpm.

HPCS Motor current is cycling between 200 and 340 amps.

Which of the following would cause these conditions?

A. Cycling Min Flow Valve B. Damaged Thrust Bearing C. Low Cycled Condensate Tank Level D. Clogged Suppression Pool Suction Strainer ANSWER:

Reference:

Task / Objective:

Question Source:

Question D

LOA-PC-10 1, 061.00.014 New Difficulty:

Section A.3 Explanation:

HPCS in not normally aligned to the CY tank for the quarterly surveillance. Min Flow valve will not pass enough flow to give these indications. A damaged thrust bearing would not cause cyclic changes.

2003 LaSalle lnitial License Operator Examination REA C TOR 0 PERA TOR

Q# 80 RO Ro 212000 2.4.50 Ro 3.3 sRo 3.3 High 2

SRO 1

Reactor Protection System Ability to verify system alarm setpoints and operate controls identified in the alarm response manual.

Emergency Procedures and Plan Unit 1 is operating at 75% power.

0 0

LOR IH13-P603-B106, CHAN Al/Bl TCV FAST CLOSURE is received.

All Scram Group Solenoid Lights are illuminated.

The ## 1 Turbine Control Valve is observed closed.

Reactor power, pressure and level remain steady.

What actions, if any should be taken?

A. No actions required.

B. Manually insert a scram on A RPS subchannel.

C. Manually insert a scram on B RPS subchannel.

D. Insert a manual full scram.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question B

LOR lH13-P603-B106 049.00.10 New Difficulty:

Explanat ion:

Receipt of LOR lH13-P603-B106 should initiate a scram of A RPS subchannel. If auto actions fail, the RO should take manual action.

2003 LaSaile Initial License Operator Examination REACTOR OPERATOR

Ro '

212000 A4.09 Ro 3,9 sRo 3.8 Memory 2

SRO 1

Reactor Protection System SCRAM instrument volume level Ability to manually operate andor monitor in the control room:

Unit 2 is at 80% power.

What affect, if any, would placing the SDV Bypass Switch in the BYPASS position have on the associated scrams and rod blocks?

SCRAM ROD BLOCK A.

Bypassed NOT Affected B.

Bypassed Bypassed C.

NOT Affected NOT Affected D.

NOT Affected Bypassed ANSWER:

Reference:

C LP49 p. 19 Task / Objective:

Question Source:

Question 049.00.05 New Difficulty:

Explanation:

C is correct because the High Level Scram bypass is only in affect if the MODE switch S/D or Refhel and switch in bypass. At 80% power, the MODE switch would have to be in RUN.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro 216000 A2.13 2.8 3.0 Ro SRo High Q# 82 2

SRO 1

RO Ability to (a) predict the impacts of the following on the NUCLEAR BOILER INSTRUMENTATION; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations:

Nuclear Boiler Instrumentation Instrument isolation valve openings Unit 2 is at 100% power.

PROVIDE PRINTS FOR REFERENCES The equalizing valve for the Reactor Low Water Level 1 ECCS Initiation Instrument Channel C transmitter, 2B2 LN407C is OPENED.

Which of the following describes (1) the impact this would have on the level indicator fed from this instrument, AND (2) the action that would be required if an actual Level 1 condition were to occur?

(Restrict your answer to the impact on the Reactor Low Water Level 1 ECCS Initiation Instrument Channel C transmitter, 2B2 1 -N407C ONLY.)

A. (1) Indicated level would be HIGHER than actual.

(2) LPCS would have to be manually initiated.

B. (1) Indicated level would be LOWER than actual.

(2) LPCS would inject when required.

C. (1) Indicated level would be HIGHER than actual.

(2) LPCS would inject when required.

D. (1) Indicated level would be LOWER than actual.

(2) LPCS would have to be manually initiated.

ANSWER:

Reference:

Task 1 Question Question A

PROVIDE PRINTS FOR REFERENCES 1E-Objective:

Source:

Difficulty:

2-42002C3, lE-2-4221MAD 040.00.021 New GP GFE LP #7, pp 32,33,43 Explanation:

The equalizing valve isolates the high pressure sensing leg from the low pressure sensing leg. With the valve open, the reference and variable leg pressures would equalize causing the level instrument to indicate higher than actual level.

Following the schematics, on 4200ZC, the N407C Level Transmitter will pevent the N707C Trip Device from ever seeing a low level signal, which will prevent energizing the K707CX Relay. This relay will fail to actuate a contact on 4221AD (31d Leg from the left). This will prevent energizing the K3 relay, which should close a contact in the KIO logic leg (IOth leg from the left). The K10 logic string is a type of I out of 2 taken twice. The K2 and K3 contacts are the Low Level Contacts. The K4 and K5 contacts are the High Drywell Pressure contacts. If an actual Level 1 signal existed, the K2 contact would close (from the A logic), but the K3 would not close, therefore not energizing the K10 contact, which ultimately feeds into the pump start logic through the K12 relay.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

The pump would, however start on a high drywell pressure signal, or a combination of the A Level and C DW pressure signals.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Q# 83 Ro Ro 216006 K6.02 Ro 2.8 SRo 3.0 Memory 2

SRO 1

Knowledge of the effect that a loss or malfunction of the following will have on the NUCLEAR BOILER INSTRUMENTATION:

Boiler Instrumentation D.C. electrical distribution A loss of DC Bus 1 12X will result in a loss of indication on...

A. Division 1 Wide Range Level.

B. Division 2 Wide Range Level.

C. B Narrow Range Level.

D. C Narrow Range Level.

ANSWER

Reference:

Task / Objective:

Question Source:

Question C

NB Jnst LP pg. 35 040.00.16 N

Difficulty:

RWLC LP pg. 30 Explanation:

A and B are AC, D is 111Y.

I 2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

I

-c 1

1 RO SRO High Ro 219000 A1.09 3.2 3.3 Q# 84 RO 2

SRO 2

Ability to predict and/or monitor changes in parameters associated with operating the RHWLPCI: TORUS/SUPPRESSION POOL COOLING MODE controls including:

RHR/Lpcl: Toms/Suppression Pool Cooling Mode Suppression chamber air temperature: Plant-Specific Unit 2 Suppression Pool temperature and Suppress Chamber air temperature are both 105°F following a transient.

Suppression pool water level is 16 inches BELOW normal.

Which of the following describes the expected response of Suppress Chamber air temperature if 2A RHR is placed in Suppression Pool Cooling mode?

Suppression Chamber air temperature would decrease (1 1 Suppression Pool temperature and could be monitored on temperature indicators on the (2) panel.

A. (1)BEFORE (2) 2H13-P601 B. (1)BEFORE (2) 2PM13J C. (1)AFTER (2) 2H13-P601 D. (1)AFTER (2) 2PM13J ANSWER:

Reference:

Task / Objective:

Question Source:

Question D

LGA7 LP(LGA-003) 42 1.00.01 New Difficulty:

LP Figure 64-1 5 Explanation:

The Suppression Chamber air temperature would only be reduced after the Suppression Pool temperature decreased since all piping is below the normal water level. The upper Suppression pool temperature sensors are located 12 inches below the normal Suppression Pool water level and feed indication on the PM 13 JA and B panels. The Suppression Pool temperature indication provided on the 2H13-P601 are fed by temperature sensors located -12 feet in the Suppression.

2003 LaSalle Mia1 License Operator Examination REACTOR OPERA TOR

Ro SRo Memory Q# 85 RO TIER GROUP RO 1

223001 2

SRO 1

K1.ll 2.7 2.9 Knowledge of the physical connections andor cause-effect relationships between PRIMARY CONTAINMENT SYSTEM AND AUXILIARIES and the following:

Primary Containment System and Auxiliaries Post accident sampling system The primary containment CAM Local Sample Panel 1PL75J @Point CAM) shares its Drywell and Suppression Chamber sample taps with the...

A. 1A Post LOCA Monitor B.

1 B Post LOCA Monitor C. 1A Oxygen Monitor D. 1B Oxygen Monitor ANSWER:

Reference:

A LOP-CM-01, D.4.

Explanation:

A is correct per the reference.

Task /Objective:

Question Source:

Question 092.00.-03 LORT Exam Bank, Difficulty:

  1. LOP-CM-01 002 2003 LaSalle Initial License Operator Examination REACTOR OPERA TOR

Q# 86 RO RO SRO High Ro 223002 K4.05 2.9 3.,

2 SRO 1

Primary Containment Isolation Knowledge of PCIS/NSSSS design feature(s) and/or interlocks which SystemMuclear provide for the follow~g:

Shut-Off Single failures will NOT impair the function ability of the system Unit 1 is operating at power when the PCIS Group 1 K7A relay fails open, de-energizing the K5 I Relay which de-energizes solenoid 3 for the Inboard MSIVs and de-energizes solenoid 2 for the outboard MSIVs.

Which of the following is the expected response of the MSIVs to this failure?

INBOARD OUTBOARD Provide Electrical Prints IE-I-4203AB-AF, A U A.

Remain Open Remain Open B.

Close Close C.

Close Remain Open D.

Open Close ANSWER:

Reference:

Task / Objective:

Question Source:

Question A

LP 091 Att. A 09 1.00.08 Bank Difficulty:

Provide Electrical Prinfs IE-I-4203AB-AF, AU Explanation:

In order for the MSIVs to close, both solenoids must de-energize. For this failure, only one solenoid is de-energized for any MSIV. Therefore, all MSIVs will remain open.

2003 LaSalle lnitial License Operator Examination REACTOR OPERATOR

Q# 87 RO Ro 241000 2.4.49 4.0 Ro SRo 4.0 High 2

SRO 1

ReactorRurbine Pressure Regulating System Emergency Procedures and Plan Ability to perform without reference to procedures those actions that require immediate operation of system components and controls.

Unit 2 has scrammed.

0 0

0 The MSIVs and SRVs are closed.

Reactor pressure is 1080 psig.

Reactor water level is -3 inches.

Which of the following actions should the reactor operator take FIRST?

A. Start RCIC in the pressure control mode.

B. ARM and DEPRESS the ADS pushbuttons.

C. Press the Bypass Jack INCREASE pushbutton.

D. Place the control switches for SRVs S and U in OPEN.

ANSWER:

Reference:

Task / Objective:

Question Source:

Quest ion D

HU-AA-104-10 1 614.010 New Difficulty:

Explanation:

Reactor pressure is above the automatic set point to open SRVs S and U.

LGA-001 requires reactor pressure to be stabilized below 1059 psig. The MSIVs are closed preventing use of BPVs. HU-AA-I 04-101 provides authority for operators to take actions required to manually duplicate an automatic action that has failed to automatically occur may be performed &om memory during transient conditions.

2003 LaSalle lnitial License Operator Examination REACT0 R 0 PERATO R

Ro sRo Memory TIER GROUP RO 1

241000 2

SRO 1

K4.10 2.5 2.5 Knowledge of REACTORiTURBINE PRESSURE REGULATING SYSTEM design feature(s) and/or interlocks which provide for the ReactorlTurbine Pressure Regulating System following:

Turbine shell warming: EHC-Only Which of the following indications provide for MAXIMUM heatup during shell warming?

(1)

Turbine Stop Valve position meter is indicating (2)

A. (1) #1 (2) 10%

B. (1) #1 (2) 100%

c. (1) #2 (2) 10%

D.

(1) #2 (2) 100%

ANSWER:

Reference:

Task I Objective:

Question Source:

Question C

074, EHC Electrical 074.00.05 NEW Difficulty:

Lesson Plan, page 23/44 Explanation:

When shell warming is selected, all turbine control valves are fully open and the #2 Turbine Stop Valve internal pilot valve can be throttled to an indicated 10% stem position. The #2 TSV position demand signal will indicate between 0-1 00%.

2003 LaSalle lnitial License Operator Examination REACTOR OPERATOR

Q# 89 RO Ro SRo Memory TIER GROUP RO 1

259001 2

SRO 2

2'4'6 3.1 4.0 Reactor Feedwater System Knowledge symptom based EOP mitigation strategies.

Emergency Procedures and Plan During a power ATWS and after Hot Shutdown Boron has been injected, LGA-010 directs the operator to raise RPV level above +I 1 inches, then to hold level between +11 and +59.5 inches.

The reason for raising level here is to...

A. clear the Level 3 shutdown cooling isolation signals.

B. clear the Level 3 scram signals, so the scram can be reset.

C. increase natural circulation to improve boron mixing.

D. ensure accurate nuclear instrumentation response.

ANSWER:

Reference:

Task f Objective:

Question Source:

Question C

LGA 012 (LGA-010 LP) 400.00.14 Bank Difficulty:

p.35 LORT LGA-0 10 002 Explanation:

The reason reactor water level is raised is to improve boron mixing.

2003 LaSalle Initial License Operator Examination REACTOR OPERA TOR

RO SRO High Ro 261000 K1.07 3.1 3.2 Q# 90 RO 2

SRO 1

Knowledge of the physical connections and/or cause-effect relationships between STANDBY GAS TREATMENT SYSTEM and the following:

Standby Gas Treatment System Elevated release stack Following a Loss of Coolant Accident, the Standby Gas Treatment (SBGT) System has been in service for several hours venting the drywell, in accordance with LGA-VQ-01, Containment Vent.

SBGT WRGM indicates elevated release rates.

Which of the following could explain the elevated release?

A. Charcoal Adsorber access door NOT fully closed.

B. Pre-Filter differential pressure increase of 2.0 inches water.

C. Moisture Separator differential pressure increase of 1.O inches water.

D. Electric Heater Temperature Controller failure below the controller setpoint.

ANSWER:

Reference:

Task / Objective:

Question Source:

Quest ion D

095, Standby Gas 095.00.2 1 Modified fiom FERMI 2 Difficulty:

Treatment Lesson Plan, Page 26 of 35, second ILO Exam, 06/14/0 1 paragraph Explanation:

The purpose of the electric heater is to raise the relative humidity entering the charcoal train. If relative humidity were to increase, the adsorption properties of the charcoal would decrease, resulting in less iodine being held-up in the train, causing release rates to increase.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro 288000 A3.01 Ro 3.8 SRo 3.8 Memory Q# 91 Ro 2

SRO 3

Plant Ventilation Systems Ability to monitor automatic operations of the PLANT VENTILATION SYSTEMS including:

Isolatiodinitiation signals Which of the following conditions automatically starts the Unit 1 Standby Gas Treatment (SBGT) Train?

A. Unit 1 Reactor Water Level of -25 inches.

B. Actuating the Unit 2 manual initiation for SBGT.

C. Reactor Building differential pressure less than -0.25 inch water.

D. Failure of the Unit 1 Reactor Building Vent Isolation damper lVR04Y to the closed position.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question B

095, Standby Gas 095.00.05 LaSalle ILT bank Difficulty:

Treatment Lesson Plan, 095.00.08 030 Page 168~27 Explanation:

B is the only statement that will cause an auto start of the Unit 1 SBGT.

2003 LaSalle M i a / License Operator Examination REACTOR OPERATOR

Q# 92 RO Ro 290002 A2.05 Ro 3.7 SRo 4.2 High 2

SRO 3

Ability to (a) predict the impacts of the following on the REACTOR VESSEL INTERNALS; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations:

Reactor Vessel Internals Exceeding thermal limits During performance of the shiftly surveillance, MFLCPR is discovered to have increased from a value of 0.980 to 1.003.

Based on this information you can conclude that the number of he1 clad failures will...

A. 'increase significantly and reactor power must be reduced per LGP-3-1, Power Changes.

B. increase significantly and reactor power must be reduced per LGP-3-2, Reactor Scram.

C. remain relatively stable but reactor power must be reduced per LGP-3-1, Power Changes.

D. remain relatively stable but reactor power must be reduced per LGP-3-2, Reactor Scram.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question C

Tech Spec 3.2.2 020.00.21 Modified, 2000 LaSalle Difficulty:

BWR Thermodynamics O2 1*00-24 ILT exam Chapter 9, pp 1 3-15 Explanation:

The MFLCPR compares the Operating MCRP to the Operating MCPR Limit. This limit is set much higher than the actual CPR value to ensure that CPR is NOT exceeded. By slightly exceeding the MFLCPR, the number of fuel clad failures will NOT increase, however the safety margin is drastically reduced. Reactor power must be reduced but the reactor does not have to be scrammed.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Q# 93 Ro RO SRO High Ro SRO 2 295020 AA2.04 3.9 3.9 1

Ability to determine andor interpret the following as they apply to Inadvertent Containment Isolation MADVERENT CONTAMMENT ISOLATION:

Reactor pressure Due to an error in performing surveillance, an MSIV isolation has occurred while operating at full power for an extended period of time.

If no operator action is taken, which of the following indicates the expected range of reactor pressure 30 minutes after the MSIV's have closed.

A. 768 to 854 psig B. 896 to 1006 psig C. 926 to 1046 psig D. 976 to 1076 psis ANSWER:

B Explanation:

Reference:

Task I Objective:

Question Source:

Question LP 070, Main Steam, 070.00.12 based on Fermi2 2,Section III.D.2, pp 10 O f GFES RX Theory, 4/6/98 exam 50 Chapter 8, Obj. 3 1.

BWR GP GFES Rx Theory, Chapter 8, Page 29 of 34.

Difficulty:

With the unit a full power for extended period of time, the decay heat rate would be high at the time of the scram. This decay heat would be approximately 7 percent following the scram and at 30 minutes would be 1 -

2%.

Following the MSIV Isolation, several SRVs would initially open, activating the Lo-Lo Set Logic. Since 1 SRV can pass approximately 7 percent steam flow, once the initial pressure transient is over, one SRV can handle the decay heat load, The S SRV has the lowest LLS Setpoint of 896 to 1006 psig.

2003 LaSalle lnifial License Operator Examination REACTOR OPERATOR

Q# 94 RO TIER GROUP RO 3

29502, RO SRO High 1

SRO 2

24.4 4.0 4.3 Loss of Shutdown Cooling Emergency Procedures and Plan Ability to recognize abnormal indications for system operating parameters which are entry-level conditions for emergency and abnormal operating procedures.

Unit 1 is operating with A RHR is in Shutdown Cooling.

0 Suppression Pool Level is at +2 inches and being lowered per LOP-RH-16, Raising and Lowering of Suppression Pool Level.

The 1E12-F064A, A RHR Pump Min. Flow, fails open.

Reactor Vessel level lowers to +IO inches.

Suppression Pool Level increases to +3.5 inches.

0 0

0 Given the above transient...

(1) what is the status of A RHR system, AND (2) what LGAs, if any, are you in?

A. 1) Running on min. flow

2) None B. 1) Running on min. flow
2) LGA-001 RPV CONTROL and LGA-003 PRIMARY CONTAINMENT CONTROL.

C. 1) Isolated

2) None.

D.

1) Isolated
2) LGA-001 RPV CONTROL and LGA-003 PRIMARY CONTAINMENT CONTROL.

ANSWER:

Reference :

Task / Objective:

Question Source:

D LOP-PC-03 p. 13 4 13.00.01 N

Quest ion Difficulty:

Explanation:

+11 inches will cause a Group VI isolation and entry conditions for LGA-001 and LGA-003.

2003 LaSalle Initial License Operafor Examination REACTOR OPERATOR

Q# 95 RO High Drywell Pressure LPCS: Plant-Specific Ro 295024 EK2.03 Ro 3.8 sRo 3,8 High 1

. SRO 1

Knowledge of the interrelations between HIGH DRYWELL PRESSURE and the following:

Unit 1 is in Cold Shutdown when an inadvertent Division 1 High Drywell pressure signal is received.

Which of the following describes the operation of the LPCS Injection Valve under these conditions?

A. Will NOT open unless RPV water level is less than -129 inches.

B. Automatically opens and CANNOT be remotely closed until the initiation signal is cleared.

C. Automatically opens; will close and remain closed when the control switch is placed in the closed position and released.

D. Automatically opens; will close when the control switch is placed in the closed position but will reopen after it has reached the full closed position.

ANSWER:

Reference:

C LP 63 p. 13 I

Task / Objective:

Question Source:

Question 063.00.18 ILT System Bank Difficulty:

064.00.14 003 Explanation:

The conditions to activate the manual override logic have been met, an initiation signal, and RPV pressure less than 500 psig. The valve will go closed and seal in closed.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Ro SRo Memory Ro 295028 EA2.06 3.4 3.7 Q# 96 RO 1

SRO 2 Ability to determine and/or interpret the following as they apply to HIGH DRYWELL TEMPERATURE:

High Drywell Temperature Toruslsuppression chamber air space temperature: Plant-Specific Which of the following would be exceeding the design limit for the primary containment?

A. Drywell Temperature of 285°F.

B. Suppression Chamber Temperature of 285°F.

C. Drywell Pressure of 42 psig.

D. Suppression Chamber Pressure of 42 psig.

ANSWER:

Reference:

Task I Objective:

Question Source:

Question B

090, Primary 090.00.01 New Difficulty:

Containment Lesson Plan, page 10 of 35, Section 1II.D.

Explanation:

B is correct per the reference. Drywell temperature design is 340F, and internal pressure is 45 psig for both.

2003 LaSalle lnitial License Operator Examination REACTOR OPERATOR

Q# 97 RO RO SRO High 3.7 Ro 295032 EA1.03 3.7 1

SRO 2

High Secondary Containment Area Temperature Secondary containment ventilation Ability to operate andor monitor the following as they apply to HIGH SECONDARY CONTAINMENT AREA TEMPERATURE:

Unit 1 at rated conditions.

1 H 13 P60 1-F404 LD MSL PIPE TUNNEL AMB TEMP HI in alarm.

MSL Pipe Tunnel Temperatures verified at 160°F and steady.

MSL Pipe Tunnel Diff. Temperatures at 22°F and steady.

Based on the above conditions, actions required include performance of...

A. LOA-MS-10 1, Main Steam System Abnormal and LGP 3-2 Reactor Scram.

E. LOA-MS-101, Main Steam System Abnormal and LGA-002 Secondary Cont. control.

C. LOA-VR-101, Unit 1 Recovery from a Group 4 Isolation or Spurious Trip of Reactor Building Vent and LGP 3-2 Reactor Scram.

D. LOA-VR-101, Unit 1 Recovery from a Group 4 Isolation or Spurious Trip of Reactor Building Vent and LGA-002 Secondary Cont. Control.

ANSWER:

Reference:

Task / Objective:

Question Source:

Question B

LOA-MS-101 page 3/10, 416.001 Modified Difficulty:

LGA-002, and LAP-820-1 1 TG page 1421155 llTG and LGA-002.

PROVIDE LAP-820-Explanation:

No conditions exist that require a scram or S/D. No conditions exist that would have isolated VR. LGA-002 is entered because the alarm indicates >Max Normal Temp. (ref. LAP-820-1 1TG p. 142).

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR

Q# 98 Ro RO SRO High Ro SRO 1

GENERIC 2.1.10 2.7 3.9 3

Conduct of Operations Knowledge of conditions and limitations in the facility license.

Unit 1 is shutdown.

Average Reactor Coolant temperature is currently 229"F, with a steady cooldown rate of lO"F/Hr Which of the following indicates the earliest that the unit will be in MODE 4?

A. 90 minutes B.

120 minutes C.

150 minutes D. 180 minutes ANSWER:

Reference:

Task / Objective:

Question Source:

Question 005.00.22 New Difficulty:

D TS Table 1.1-1 Explanation:

Mode 4 is defined as Mode switch in shutdown, Avg. Coolant Temp 5 200"F, and all rx vessel head bolts tight. Since this is a cooldown for a refbel outage, all bolts are tight. With temperature at 229°F and a 1 O"F/Hr Cooldown rate, it will take 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> to be less than or equal to 200°F.

2003 LaSalle lnitial License Operator Examination REACTOR OPERATOR

Q# 99 Ro Ro SRO 1

GENERIC 2.2.22 Ro 3.4 SRo 4.1 Memory 3

Equipment Control Knowledge of limiting conditions for operations and safety limits.

Which of the following combinations of reactor power and pressure indicate violation of a Safety Limit?

Reactor Power Reactor Pressure A.

22%

735 psig B.

28%

820 psig C.

2 6%

750 psig D.

20%

740 psig ANSWER:

Reference:

Task / Objective:

Question Source:

Question C

TS Safety Limits 2.1.1 020.00.22 LaSalle 2002 Cert Exam Difficulty:

Explanation:

Safety Limit Violation if reactor power is >25% with pressure less than 785 psig. C. is only choice with correct combination of conditions.

2003 LaSalle lnitial License Operator Examination REACT0 R 0 PERA TOR

Ro GENERIC 2.2.30 Ro 3.5 SRo 3.3 Memory Q# 100 RO 3

SRO 1

Equipment Control Knowledge of RO duties in the control room during fuel handling such as alarms from fuel handling area /

communication with fuel storage facility / systems operated from the control room in support of fueling operations / and supporting instrumentation.

Which of the following is a responsibility of the Reactor Operator during core alterations?

A. Maintain the official copy of the Nuclear Component Transfer List.

B. Observe Source Range Monitors for rising counts.

C. Perform verification of in-core coordinates.

D. Observe and directly supervise Core Alterations.

Question Difficulty:

ANSWER:

Reference:

Task / Objective:

Question Source:

B LFP-100- 1, Rev. 3 8, (task) 30.002 CPS ILTO 10 1 NRC Page 16 of 49 Exam Explanation:

B is correct per the reference. The official copy of the NCTL is maintained on the rehel bridge, the RO cannot verify in-core coordinates from the Main Control Room and also cannot observe or supervise the core alterations from the Main Control Room.

2003 LaSalle Initial License Operator Examination REACTOR OPERATOR