Attachment 1 2CAN060306 Analysis of Proposed Technical Specification Change to 2CAN060306 Page 1 of 11
1.0 DESCRIPTION
This letter is a request to amend Operating License NPF-6 for Arkansas Nuclear One, Unit 2 (ANO-2).
The proposed change will revise the ANO-2 Technical Specifications (TSs) to: 1) eliminate credit for the Boraflex neutron absorbing material used for reactivity control in Region 1 of the Spent Fuel Pool (SFP); 2) credit a combination of soluble boron and several defined 2 x 2 fuel patterns within the storage racks to maintain SFP reactivity within the effective neutron multiplication factor (keff) limits of 10 CFR 50.68; 3) increase the minimum soluble boron concentration in the SFP to 2000 parts per million (ppm); and 4) reduce the fresh fuel assembly initial enrichment to less than or equal to 4.55+/-0.05 weight percent (wt%) uranium-235 (U-235).
Approval of this amendment is needed for the fall 2003 refueling outage in order to allow full core offload capability.
2.0 PROPOSED CHANGE
The proposed amendment will: 1) eliminate credit for the Boraflex neutron absorbing material used for reactivity control in Region 1 of the SFP; 2) credit a combination of soluble boron and several defined 2 x 2 fuel patterns within the storage racks to maintain SFP reactivity within the keff limits of 10 CFR 50.68; 3) increase the minimum soluble boron concentration in the SFP to 2000 ppm; and 4) reduce the fresh fuel assembly initial enrichment to less than or equal to 4.55+/-0.05 wt% U-235.
TS 3.9.12.a currently allows storage of fuel assemblies having an initial enrichment less than or equal to 5.0 wt% U-235 in the spent fuel pool. The fuel assembly initial enrichment will be changed based on the reactivity analysis performed to support the proposed change. The new fuel assembly initial enrichment will be limited to less than or equal to 4.55+/-0.05 wt% U-235.
Changes are proposed to TS 3.9.12.b which describes the fuel loading restrictions in the currently defined Regions 1 and 2. Five 2 x 2 storage patterns along with their interfacing relationships are proposed that will allow credit for a combination of soluble boron and fuel positioning within the storage racks to maintain SFP reactivity. The five patterns include a combination of various fuel enrichments, fuel burnup, fuel cooling times, assemblies with Control Element Assemblies (CEAs) inserted and without CEAs inserted, and water cells.
Different fuel types or vacant spaces as defined below will be specified within the 2 x 2 patterns.
F - fresh fuel assemblies with an initial enrichment less than or equal to 4.55+/-0.05 wt%.
B - an assembly with a maximum initial enrichment of 4.1 wt%, a minimum burnup of 11.3 GWD/MTU and zero years cooling time. Typically B type assemblies have only one cycle of burnup.
Fc - fresh fuel assemblies with an initial enrichment of less than or equal to 4.55+/-0.05 wt% with a CEA inserted. The CEA must be one that is of the new design.
A - an assembly that meets specific burnup requirements that will be included in the proposed change.
BC - a B type assembly with a CEA inserted. This CEA may be of the old or new design.
to 2CAN060306 Page 2 of 11 C - a high burnup assembly that meets specific burnup requirements that will be included in the proposed change. Initial enrichment is less than or equal to 4.50+/-0.05 wt%.
AC - an A type assembly with a CEA inserted. This CEA may be of the old or new design.
CC - a C type assembly with a CEA inserted. This CEA may be of the old or new design. Initial enrichment is less than or equal to 4.50+/-0.05 wt%.
X - a water cell with no fuel.
The ANO-2 CEAs incorporate in their design five "fingers." In the old design, the middle finger of the CEAs is of a different design, using a 8 1/2 inch inconel slug in the bottom of the fingers. The outer fingers use a 12 1/2 inch silver, indium, cadmium (Ag-In-Cd) slug in the bottom of the fingers. The bottom of the fingers of the new CEAs all have a12 1/2 inch Ag-In-Cd tip.
The five loading patterns, which will be reflected in TS Figure 3.9-2, have been evaluated to consider the reactivity effects based on various interfacing combinations. The allowable pattern interfaces will also be reflected in TS Figure 3.9-2.
A change to TS 3.9.12.c is proposed that will increase the SFP boron concentration to 2000 ppm. Since soluble boron will be credited to maintain SFP reactivity, the increase in the TS boron concentration will provide additional margin.
Supporting changes are also proposed to the Action and the Surveillance Requirements (SRs) associated with TSs 3.9.12.a, 3.9.12.b and 3.9.12.c. In addition, Note 1 will be deleted. The new criticality analysis does not support use of the vacant spaces defined in the Note.
The current minimum burnup verses initial assembly average U-235 loading curve depicted in TS Figure 3.9.2 will be deleted. New information reflecting the allowable 2 x 2 loading patterns, the acceptable interfaces between the five patterns, the minimum burnup requirements of type A and C assemblies at varying enrichment and cooling times, and bounding polynomial equations used to determine the minimum acceptable burnup for type A and C assemblies will be added as the proposed TS Figure 3.9-2.
A change to TS 5.3.1.b is proposed stating that keff will be maintained less than or equal to 0.95 when credit for 240 ppm of boron is taken. The current TS 5.3.1.c will become 5.3.1.d and a new TS 5.3.1.c will be added stating that keff will remain below 1.0 if the pool is flooded with unborated water.
A change is also proposed to TS 5.3.2.a to limit the new fuel assembly U-235 enrichment to 4.55+/-0.05 wt%. Due to restrictions considered in the spent fuel storage criticality analyses, the maximum initial fuel enrichment will be restricted to 4.55+/-0.05 wt%. This impacts the discussion of the new fuel storage rack design in TS 5.3.2. This change is a conservative restriction on fuel enrichment and does not have any adverse impact on the new fuel rack design.
The font will be changed on all pages, which is considered an editorial change and will not be discussed further.
A new criticality analysis has been performed to support this amendment request. A License Amendment Report was prepared by Holtec International to summarize the methodology, to 2CAN060306 Page 3 of 11 assumptions, and results of the new analysis based on partial credit for soluble boron and other neutron absorbers, other than Boraflex. The report is included as Attachment 5 to this amendment request.
A boron dilution analysis was also prepared for the proposed change to demonstrate that an inadvertent dilution event would not reduce the SFP boron concentration to a value less than the minimum requirement of the criticality analysis. The conclusions of the boron dilution analysis are included in Attachment 5.
In summary, the proposed change will allow the use of several defined 2 x 2 loading patterns in the ANO-2 SFP, while taking credit for boron, as a means of maintaining SFP reactivity within the keff limits of 10 CFR 50.68.
Changes are also proposed to the TS bases which are included for information only in.
3.0 BACKGROUND
The proposed change is requested to allow an alternate loading pattern for fresh and spent fuel assemblies in the ANO-2 SFP. Currently, storage of fuel assemblies in the SFP is governed by ANO-2 Technical Specifications (TS) 3.9.12.a, 3.9.12.b, 3.9.12.c, 5.3.1, 5.3.2, and 5.3.4. As is depicted in TS Figure 3.9.1, the ANO-2 SFP is divided into two regions. Region 1 contains Boraflex, while Region 2 has no poison panel inserts. The proposed change will eliminate reliance on Boraflex and take credit for soluble boron in the SFP water.
On June 26, 1996, the Nuclear Regulatory Commission office of Nuclear Reactor Regulation issued Generic Letter (GL) 96-04, Boraflex Degradation in Spent Fuel Pool Storage Racks. The GL addressed issues concerning the use of Boraflex in SFP storage racks and requested an assessment of the capability of the Boraflex to maintain a 5 percent subcriticality margin and the submittal of a plan describing the utilitys proposed actions if the subcriticality margin cannot be maintained by the Boraflex material because of current or projected future Boraflex degradation.
ANO responded to the GL by letters dated October 24, 1996 (Arkansas Nuclear One - Units 1 and 2, 120 Day Response to Generic Letter 96-04 (0CAN109605)), January 29, 1998 (Arkansas Nuclear One-Unit 1, Revised Commitment Made in Response to Generic Letter 96-04 (1CAN019803)), and March 18, 2002 (Degradation of Boraflex in ANO-1 Spent Fuel Pool (1CAN030203)).
In the original response to GL 96-04 (letter dated October 24, 1996), Entergy outlined ANOs Boraflex monitoring program. The purpose of the monitoring program is to ensure that the 5 percent subcriticality margin can be maintained for the life of the spent fuel storage racks.
The program provides an allowance should an assessment indicate that the 5 percent subcriticality margin cannot be maintained, as follows:
In the event this assessment determines the 5 percent subcriticality margin cannot be maintained, immediate steps will be taken to maintain soluble boron levels to insure this margin is sustained. Additionally, analyses could be performed to justify continued use of the racks in unborated water based on more realistic assumptions such as credit for integral poisons, higher burnup requirements, or additional restrictions on fuel storage configurations.
to 2CAN060306 Page 4 of 11 Section 9.1.2.3 of the ANO-2 Safety Analysis Report (SAR) describes the assumptions used to perform the criticality analysis for the spent fuel storage racks. For Region 1, credit was taken for the minimum design area Boron-10 (B-10) loading in the Boraflex poison panels. In March 2003 an analysis of the Boraflex was performed that indicated the Boraflex content had dropped below the analysis assumptions. The ANO-2 SFP Region 1 racks are considered operable but degraded as allowed by Generic Letter 91-18, Information To Licensees Regarding Two NRC Inspection Manual Sections On Resolution of Degraded and Nonconforming Conditions and On Operability. The degraded condition has been documented in the plant corrective action program. Entergy is currently administratively controlling fuel storage configurations in Region
- 1. This is consistent with the actions presented in our initial response to GL 96-04.
By letter dated January 29, 2003 (License Amendment Request to Change the Spent Fuel Pool (SFP) Loading Restrictions (2CAN010304)), Entergy submitted a request to modify a portion of the Region 2 SFP racks by inserting Metamic poison panels. The proposed change took no credit for Boraflex, created spent fuel loading restrictions in Regions 1 and 2, and took credit for soluble boron. Due to unexpected manufacturing challenges, the Metamic poison panels have not been produced. Thus, in order to accommodate the known degradation of Boraflex and the ability to perform a complete core offload, an alternate loading pattern for the ANO-2 SFP is proposed.
3.1 Spent Fuel Pool Racks The ANO-2 SFP provides 988 storage locations for spent fuel assemblies or other items (e.g.
incore detectors) which require long term submerged storage. The racks are comprised of twelve free standing structures. Four modules contain 81 fuel storage locations each in a 9x9 array; four modules contain 90 fuel storage locations each in a 9x10 array; two modules contain 80 fuel storage locations in an 8x10 array; and, two modules contain 72 fuel storage locations in an 8x9 array. The SFP is lined with type 304L stainless steel and is designed to seismic Category I criteria.
Each fuel storage module is made up of rectangular storage cells which are capable of accepting one fuel assembly. The cells are open at the top and bottom to provide a flow path for convective cooling of spent fuel assemblies through natural circulation. The fuel storage cells are structurally connected to form storage modules which provide the assurance that the required minimum fuel assembly spacing is maintained for all design conditions including a design basis earthquake (DBE).
All welded construction is used in fabrication of the fuel storage cells and in the interconnection of cells to form modules. The fuel storage modules are constructed of type 304 stainless steel.
The welded construction ensures the structural integrity of the storage modules and provides assurance of smooth snag-free paths in the storage cells so that it is highly improbable that a fuel assembly could become stuck in the racks.
ANO-2 SAR Section 9.1.3 contains a detailed description of the ANO-2 SFP, the associated structural and seismic considerations, the fuel rack structural analysis, the pool structural analysis, the criticality analysis for Regions 1 and 2, the postulated spent fuel storage criticality analysis, and the testing and inspection requirements. Based on approval of the proposed changes, the appropriate section of the SAR will be revised.
to 2CAN060306 Page 5 of 11 TS 3.9.12.b currently defines two storage regions (Region 1 and Region 2), each of which has specified loading restrictions based on assembly average burnup in GWD/MTU and the initial assembly average U-235 loading per unit length (g/inch). TS Figure 3.9.2 was initially included in the ANO-2 TSs with the approval of TS Amendment 43 (NRC Safety Evaluation Report (SER) dated April 15, 1983). The amendment allowed modification of the SFP racks which resulted in increased storage capacity in the pool and the addition of Region 1 which contains Boraflex.
TS Figure 3.9.2 was subsequently modified with the approval of TS Amendment 178 (NRC SER dated January 14, 1997). This amendment allowed an increase in the initial fuel enrichment from 4.1 weight percent (w/o) to 5.0 w/o. The criticality analysis performed based on the higher initial enrichment resulted in changes to TS Figure 3.9.2. TS 3.9.12.a. was also modified.
TS Amendment 224 (NRC SER dated October 24, 2000) allowed an alternate storage configuration of fuel assemblies adjacent to the walls within Region 1 of the SFP provided they were less reactive than the area of the graph enclosed by Curve A on TS Figure 3.9.2. This change provided 17 additional storage locations. This allowance was incorporated with the insertion of Note 1.
The controls used in determining the storage location for new and irradiated fuel in the SFP are governed by procedure. The procedure currently contains guidelines pertaining to restricted and unrestricted fuel storage as reflected by TS Figure 3.9.2. The new loading pattern restrictions will continue to be governed by procedure. Checkerboard storage configurations will be procedurally controlled with the vacant spaces administratively controlled by procedure.
3.2 Spent Fuel Pool System The fuel pool system is designed to:
maintain the pool temperatures less than or equal to approximately 150°F during a full core discharge. The cooling systems heat removal capacity is a function of service water temperature. Refueling operations are administratively controlled in order to minimize the potential of exceeding a pool temperature of 150°F during a full core discharge whenever service water system temperature is elevated.
maintain purity and optical clarity of the fuel pool water.
maintain purity of the water in the refueling cavity and in the refueling water tank.
maintain the water level a minimum of 9.5 feet above the top of the active fuel during fuel handling and storage operations.
The cooling portion of the fuel pool system is a closed loop system consisting of two half-capacity pumps for normal duty and one full-capacity heat exchanger. The fuel pool water is drawn from the fuel pool near the surface and is circulated by the fuel pool pumps through the fuel pool heat exchanger where heat is rejected to the service water system. From the outlet of the fuel pool heat exchanger, the cooled fuel pool water is returned to the top of the fuel pool via a distribution header at the end of the pool opposite from the intake.
to 2CAN060306 Page 6 of 11 The clarity and purity of the water in the fuel pool, refueling cavity, and refueling water tank are maintained by the purification portion of the fuel pool system. The purification loop consists of the fuel pool purification pump, ion exchanger, filters, and strainers. The purification flow is drawn from the bottom of the fuel pool. A basket strainer is provided in the purification line to the pump suction to remove any relatively large particulate matter. The fuel pool water is circulated by the pump through a filter which removes particulates and through an ion exchanger to remove ionic material. Connections to the refueling water tank and refueling water cavity are provided for purification and makeup.
Makeup to the fuel pool is provided from the Chemical and Volume Control System via the blending tee, the refueling water tank via the purification pumps, or the Boron Management System (BMS) holdup tanks if chemistry specifications are met. In an emergency, Seismic Category I makeup is available from either service water system loop. The boric acid makeup tanks are also available for boration of the SFP. Overflow protection is provided by transferring the fuel pool water to the refueling water tank or one of the BMS holdup tanks via the purification pump on high level alarm.
A detailed description of the SFP system is included in Section 9.1.3 of the ANO-2 SAR. No modifications are proposed to the SFP system in order to support the proposed change.
4.0 TECHNICAL ANALYSIS
of this letter provides a detailed technical analysis in support of the proposed changes. Below is a brief summary of the attachment.
4.1 Criticality Considerations A criticality analysis was performed for the ANO-2 SFP racks and spent fuel currently in the SFP and the core. Five 2 x 2 fuel patterns and their interfacing relationship were established. These patterns and interfaces were analyzed as acceptable loading configurations to ensure keff is less than or equal to 0.95 within the storage racks when credit is taken for soluble boron. The analysis also demonstrated that keff is maintained less than 1.0 under the assumed accident of the loss of soluble boron in the pool water.
4.2 Accident Analysis Temperature and water density effects and lateral rack movement were analyzed. The maximum bulk pool water temperature was included in the analysis as a bias in the calculation to assure the true reactivity will be lower over the expected range of water temperatures. The analysis evaluated the effect of lateral motion of the storage racks under postulated seismic conditions. Under these conditions credit will be taken for soluble boron.
The analysis also considered a dropped assembly; a misplaced assembly, between the racks and the SFP walls; and a misplaced assembly within any of the five 2 x 2 patterns. The most limiting of these is the misplaced assembly within one of the five patterns. Assuming this accident condition, a soluble boron concentration of at least 825 ppm is required to ensure keff remains less than 0.95.
to 2CAN060306 Page 7 of 11 A boron dilution evaluation was also performed. If a dilution event were to occur, sufficient time is available to take corrective actions that will assure a 5% criticality margin is maintained.
5.0 REGULATORY ANALYSIS
5.1 Applicable Regulatory Requirements/Criteria The proposed changes have been evaluated to determine whether applicable regulations and requirements continue to be met.
By letter dated October 6, 1998, the Nuclear Regulatory Commission granted ANO-1 and ANO-2 an exemption from the requirements of 10 CFR 70.24, Criticality accident requirements. With the approval of the proposed change this exemption is no longer required.
Arkansas Nuclear One, Unit 2 (ANO-2) currently complies with the requirements of 10 CFR 50.68, Criticality accident requirements. There are eight criteria that must be satisfied in the regulation. ANO-2 complies with these as follows.
- 1) 10 CFR 50.68, (b) (1) - Plant procedures shall prohibit the handling and storage at any one time of more fuel assemblies than have been determined to be safely subcritical under the most adverse moderation conditions feasible by unborated water.
ANO-2 Response - ANO-2s fuel handling procedures ensure that subcriticality is maintained in the reactor vessel and the SFP under the most adverse moderation conditions feasible by unborated water. Storage of fuel assemblies is procedurally controlled to assure keff remains below 1.0, at a 95% probability, 95% confidence level, when flooded with unborated water.
- 2) 10 CFR 50.68, (b) (2) - The estimated ratio of neutron production to neutron absorption and leakage (k-effective) of the fresh fuel in the fresh fuel storage racks shall be calculated assuming the racks are loaded with fuel of the maximum fuel assembly reactivity and flooded with unborated water and must not exceed 0.95, at a 95 percent probability, 95 percent confidence level. This evaluation need not be performed if administrative controls and/or design features prevent such flooding or if fresh fuel storage racks are not used.
ANO-2 Response - Previously performed criticality calculations of the new fuel vault fully loaded with Combustion Engineering (CE) 16x16 fresh fuel assemblies and filled with the most reactive unborated water showed that reactivity did not exceed 0.95, at a 95%
probability, 95% confidence level.
- 3) 10 CFR 50.68, (b) (3) - If optimum moderation of fresh fuel in the fresh fuel storage racks occurs when the racks are assumed to be loaded with fuel of the maximum fuel assembly reactivity and filled with low density hydrogenous fluid, the k-effective corresponding to this optimum moderation must not exceed 0.98, at a 95 percent probability, 95 percent confidence level. This evaluation need not be performed if administrative controls and/or design features prevent such moderation or if fresh fuel storage racks are not used.
ANO-2 Response - Criticality calculations were performed on the new fuel vault fully loaded with CE 16x16 fresh fuel assemblies and filled with the most reactive low density to 2CAN060306 Page 8 of 11 hydrogenous fluid. The results of these calculations showed that reactivity did not exceed 0.98, at a 95% probability, 95% confidence level.
- 4) 10 CFR 50.68, (b) (4) - If no credit for soluble boron is taken, the k-effective of the spent fuel storage racks loaded with fuel of the maximum fuel assembly reactivity must not exceed 0.95, at a 95 percent probability, 95 percent confidence level, if flooded with unborated water. If credit is taken for soluble boron, the k-effective of the spent fuel storage racks loaded with fuel of the maximum fuel assembly reactivity must not exceed 0.95, at a 95 percent probability, 95 percent confidence level, if flooded with borated water, and the k-effective must remain below 1.0 (subcritical), at a 95 percent probability, 95 percent confidence level, if flooded with unborated water.
ANO-2 Response - Soluble boron credit will be taken in the spent fuel pool storage racks.
Reactivity will not exceed 0.95 at a 95% probability with a 95% confidence level when credit is taken for 240 ppm boron. The criticality calculations included in the proposed change show that keff remains below 1.0, at a 95% probability, 95% confidence level, when flooded with unborated water.
- 5) 10 CFR 50.68, (b) (5) - The quantity of SNM, other than nuclear fuel stored onsite, is less than the quantity necessary for a critical mass.
ANO-2 Response - ANO does not currently have a quantity of SNM, other than the nuclear fuel, stored on site to ascertain a critical mass.
- 6) 10 CFR 50.68, (b) (6) - Radiation monitors are provided in storage and associated handling areas when fuel is present to detect excessive radiation levels and to initiate appropriate safety actions.
ANO-2 Response - Radiation monitors are located in the ANO-2 SFP area which alarm in the control room. When fuel movement is in progress fuel handling procedures require placement of additional radiation monitors directly on the fuel handling bridges to provide an additional audible indication of excessive radiation levels.
- 7) 10 CFR 50.68, (b) (7) - The maximum nominal U-235 enrichment of the fresh fuel assemblies is limited to five (5.0) percent by weight.
ANO-2 Response - Per ANO-2 TS 5.3.2 and 3.9.12.a, the maximum U-235 fuel enrichment limit is 5.0 weight percent including enrichment uncertainties. The proposed change will reduce the maximum U-235 enrichment to 4.55+/-0.05 wt% U-235.
- 8) 10 CFR 50.68, (b) (8) - The FSAR is amended no later than the next update which 50.71(e) of this part requires, indicating that the licensee has chosen to comply with 50.68(b).
ANO-2 Response - The ANO-2 SAR will be amended no later than the next required update after the proposed TS change is approved and implemented. This SAR update will indicate that ANO-2 has chosen to comply with 50.68(b).
Entergy has determined that the proposed changes do not require any exemptions or relief from regulatory requirements, other than the TS, and do not affect conformance with any General to 2CAN060306 Page 9 of 11 Design Criterion (GDC) differently than described in the Updated Final Safety Analysis Report (UFSAR.)
5.2 No Significant Hazards Consideration The proposed change will modify the Arkansas Nuclear One, Unit 2 (ANO-2) Technical Specifications (TSs) to allow several defined 2 x 2 fuel loading patterns in the ANO-2 spent fuel pool (SFP). The loading patterns and their associated interfaces have been analyzed to assure a subcritical margin of five percent is maintained when credit is taken for soluble boron. The loading patterns and their associated interfaces have also been analyzed to assure the effective neutron multiplication factor (keff) remains below 1.0 (subcritical) with no credit for boron. The proposed change will also modify the current TS allowed value for fuel assembly initial enrichment and the minimum SFP soluble boron concentration.
Entergy Operations, Inc. has evaluated whether or not a significant hazards consideration is involved with the proposed amendment(s) by focusing on the three standards set forth in 10 CFR 50.92, Issuance of amendment, as discussed below:
- 1.
Does the proposed change involve a significant increase in the probability or consequences of an accident previously evaluated?
Response: No.
The fuel handling accidents described below can be postulated to increase reactivity.
However, for these accident conditions, the double contingency principle of ANS N16.1-1975 is applied. This states that it is unnecessary to assume two unlikely, independent, concurrent events to ensure protection against a criticality accident. Thus, for accident conditions, the presence of soluble boron in the storage pool water can be assumed as a realistic initial condition since its absence would be a second unlikely event.
Three types of drop accidents have been considered: a vertical drop accident, a horizontal drop accident, and an inadvertent drop of an assembly between the outside periphery of the rack and the pool wall.
A vertical drop directly upon a cell will cause damage to the racks in the active fuel region. The proposed 2000 ppm soluble boron concentration will ensure that Keff does not exceed 0.95.
A fuel assembly dropped on top of the rack that comes to rest horizontally will not deform the rack structure such that criticality assumptions are invalidated. The rack structure is such that an assembly positioned horizontally on top of the rack results in a minimum separation distance from the upper end of the active fuel region of the stored assemblies. This distance is sufficient to preclude interaction between the dropped assembly and the stored fuel.
An inadvertent drop of an assembly between the outside periphery of the rack and the pool wall is bounded by the worst case fuel misplacement accident condition.
The fuel assembly misplacement accident was considered for all storage configurations.
An assembly with high reactivity is assumed to be placed in a storage location which to 2CAN060306 Page 10 of 11 requires a fuel assembly with a lower reactivity. The presence of soluble boron in the pool water assumed in the analysis has been shown to offset the worst case reactivity effect of a misplaced fuel assembly for any configuration. This soluble boron requirement is less than the proposed 2000 ppm that will be required by the ANO-2 TS.
Thus, a five percent subcriticality margin can be easily met for postulated accidents, since any reactivity increase will be much less than the negative worth of the dissolved boron.
Therefore, the proposed change does not involve a significant increase in the probability or consequences of an accident previously evaluated.
- 2.
Does the proposed change create the possibility of a new or different kind of accident from any accident previously evaluated?
Response: No.
The proposed change will define several acceptable 2x2 loading patterns and acceptable interfaces between the patterns. In addition the proposed change will credit soluble boron to assure a five percent subcriticality margin is maintained during normal conditions and in the event of a postulated accident. The soluble boron concentration assumed in the analyses for a postulated accident is less than the proposed TS change of 2000 ppm. Thus, a five percent subcriticality margin can easily be met for postulated accidents, since any reactivity increase will be much less than the negative worth of the dissolved boron.
No new or different types of fuel assembly drop scenarios are created by the proposed change. The presence of soluble boron in the SFP water assures a subcriticality margin is maintained in the event of fuel assembly misplacement.
Therefore, the proposed change does not create the possibility of a new or different kind of accident from any previously evaluated.
- 3.
Does the proposed change involve a significant reduction in a margin of safety?
Response: No.
With the presence of a nominal boron concentration, the fuel storage patterns are designed to assure that fuel assemblies of less than or equal to 4.55+/-0.05 weight percent U-235 enrichment when loaded in accordance with the proposed loading patterns will be maintained within a subcritical array with a five percent subcritical margin (95% probability at the 95% confidence level). This has been verified by criticality analyses.
Credit for soluble boron in the SFP water is permitted under accident conditions as well as in non-accident conditions. Criticality analyses have been performed to determine the required boron concentration that would ensure a subcriticality margin of at least five percent. By increasing the minimum boron concentration to greater than 2000 ppm, the margin of safety currently defined by taking credit for soluble boron will be maintained.
to 2CAN060306 Page 11 of 11 Therefore, the proposed change does not involve a significant reduction in a margin of safety.
Based on the above, Entergy concludes that the proposed amendment present no significant hazards consideration under the standards set forth in 10 CFR 50.92(c), and, accordingly, a finding of no significant hazards consideration is justified.
5.3 Environmental Considerations The proposed amendment does not involve (i) a significant hazards consideration, (ii) a significant change in the types or significant increase in the amounts of any effluent that may be released offsite, or (iii) a significant increase in individual or cumulative occupational radiation exposure. Accordingly, the proposed amendment meets the eligibility criterion for categorical exclusion set forth in 10 CFR 51.22(c)(9). Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the proposed amendment.
2CAN060306 Proposed Technical Specification Changes (mark-up)
ARKANSAS - UNIT 2 3/4 9-14 Amendment No. 43, 178, 224, REFUELING OPERATIONS FUEL STORAGE LIMITING CONDITION FOR OPERATION 3.9.12.a Storage in the spent fuel pool shall be restricted to fuel assemblies having initial enrichment less than or equal to 5.04.55+/-0.05 w/o U-235. The provisions of Specification 3.0.3 are not applicable.
3.9.12.b Storage in Region 1 or Region 2 (as shown on Figure 3.9.1) of the spent fuel pool shall be further restricted by the limits specified in Figure 3.9.2. In the event a cross-hatch storage configuration is deemed necessary for a portion of either Region 1 or Region 2, vacant spaces diagonal to the four corners of any fuel assembly or vacant spaces on two opposite faces of any fuel assembly shall be physically blocked before any such fuel assembly may be placed in that region (Note 1). Also, the Region 1 storage cells adjacent to the Region 2 interface are restricted to fuel assemblies that are outside of the area of the graph enclosed by Curve A on Figure 3.9.2. In the event a checkerboard storage configuration is deemed necessary for a portion of Region 2, vacant spaces adjacent to the four faces of any fuel assembly shall be physically blocked before any such fuel assembly may be placed in Region 2. The provisions of Specification 3.0.3 are not applicable.
3.9.12.c The boron concentration in the spent fuel pool shall be maintained (at all times) at greater than 1600 2000 parts per million.
APPLICABILITY:
During storage of fuel in the spent fuel pool.
ACTION:
Suspend all actions involving the movement of fuel in the spent fuel pool if it is determined a fuel assembly has been placed in an incorrect location until such time as the correct storage location is determined. Move the assembly to its correct location before resumption of any other fuel movement.
Suspend all actions involving the movement of fuel in the spent fuel pool if it is determined the pool boron concentration is less than 1601 2001 ppm, until such time as the boron concentration is increased to 1601 2001 ppm or greater.
SURVEILLANCE REQUIREMENTS 4.9.12.a Verify all fuel assemblies to be placed in the spent fuel pool have an initial enrichment of less than or equal to 5.04.55+/-0.05 w/o U-235 by checking the assemblies design documentation.
4.9.12.b Verify all fuel assemblies to be placed in the spent fuel pool are within the limits of Figure 3.9.2 by checking the assemblies design and burnup documentation.
4.9.12.c Verify at least once per 31 days the spent fuel pool boron concentration is greater than 1600 2000 ppm.
Note 1:
If the most peripheral row/column of the Region I contains vacant spaces in a cross-hatch storage configuration, these vacant spaces may be filled with fuel assemblies that are outside of the area of the graph enclosed by Curve A on Figure 3.9.2, provided that the most southwest and southeast corner locations remain empty.
ARKANSAS - UNIT 2 3/4 9-16 Amendment No. 43, 178, FIGURE 3.9.2 MINIMUM BURNUP VS. INITIAL ASSEMBLY AVERAGE U-235 LOADING 0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 27.5 30.0 32.5 35.0 37.5 40.0 42.5 45.0 47.5 50.0 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.30 0.32 0.34 0.36 0.38 0.40 0.42 0.44 0.46 0.48 0.50 0.52 0.54 0.56 0.58 0.60 Initial Assembly Average U-235 Loading Per Unit Length (g/inch)
Assembly Average Burnup (GWD/MTU)
Non-restricted Restricted to Region 1 Cross-hatch or Region 2 Checkerboard Spacing Region 2 Checkerboard, to Region 1
- Storage, Restricted or Region 2 Cross-hatch Spacing Restricted to Region 1 Storage or Region 2 Checkerboard Spacing Curve A Curve B Curve C 0.614108 Curve A = 68.008x-19.366 when x > 0.399181 Curve B = 239.01x3-347.75x2+243.18x-41.452 Curve C = -714.35x4+1335.80x3-946.44x2+394.52x-47.040
ARKANSAS - UNIT 2 3/4 9-16 Amendment No. 43,178, Figure 3.9-2 Pattern 1 Pattern 2 Pattern 3 Pattern 4 Pattern 5 Legend:
- 1. Type F - fresh fuel assemblies with an initial enrichment less than or equal to 4.55+/-0.05 wt%.
- 2. Type B - an assembly with a maximum initial enrichment of 4.1 wt%, a minimum burnup of 11.3 GWD/MTU and zero years cooling time. Typically B type assemblies have only one cycle of burnup.
- 3. Fc - fresh fuel assemblies with an initial enrichment of less than or equal to 4.55+/-0.05 wt% with a CEA inserted. The CEA must be of the new design.
- 4. A - an assembly that meets specific burnup requirements that are included in Table 1 below.
- 6. C - a high burnup assembly that meets specific burnup requirements that are included in Table 2 below. Initial enrichment is less than or equal to 4.50+/-0.05 wt%.
- 8. CC - a C type assembly with a CEA inserted. This CEA may be of the old or new design. Initial enrichment is less than or equal to 4.50+/-0.05 wt%.
- 9. X - a water cell with no fuel.
Note: Any less restrictive assembly may be substituted for another assembly within the pattern. Fuel assembly types are ranked 1 through 9, with the highest reactivity ranking being 1.
BC or A BC or A BC or A BC or A F
X X
F F
C Fc B
C C
C
ARKANSAS - UNIT 2 3/4 9-17 Amendment No.
Figure 3.9-2 Allowable Pattern Interfaces Pattern 1 Pattern 2 Pattern 3, Alternate Pattern 4 Pattern 5 BC or A BC or A BC or A BC or A F
X X
F CC F
CC CC Fc C
C Fc B
C C
C
ARKANSAS - UNIT 2 3/4 9-18 Amendment No.
Figure 3.9-2 Allowable Pattern Interfaces Pattern 2 Pattern 3, Alternate Alternate Pattern 3, Alternate Pattern 4 Pattern 4, Alternate Pattern 5 Pattern 5, Alternate Pattern 5, Alternate X
F F
X CC CC F
CC CC F
CC CC Fc C
C Fc C
Fc Fc C
B C
C C
C C
B C
C B
C C
ARKANSAS - UNIT 2 3/4 9-19 Amendment No.
Figure 3.9-2 Allowable Pattern Interfaces Pattern 3 Pattern 4 Pattern 5, Alternate Pattern 4, Pattern 5 Alternate Pattern 5, Alternate Pattern 5, Alternate F
C Fc C
C B
C C
Fc Fc C
B C
C C
C C
C B
C C
B C
ARKANSAS - UNIT 2 3/4 9-20 Amendment No.
Figure 3.9-2 Table 1 Minimum Burnup Requirements for A Assemblies at Varying Enrichment and Cooling Time BURNUP, MWD/KgU Average Enrichment, wt% U-235 0 Years Cooling Time 5 Years Cooling Time 10 Years Cooling Time 15 Years Cooling Time 20 Years Cooling Time 2
7.56 7.56 7.56 7.56 7.56 2.5 14.94 14.21 13.47 12.74 12.00 3.0 21.30 20.30 19.30 18.30 17.30 3.5 27.10 25.95 24.80 23.65 22.50 4.0 32.67 31.38 30.09 28.79 27.50 4.5 39.30 37.73 36.15 34.58 33.00 4.95 45.00 43.33 41.65 39.98 38.30 Table 1-1 Bounding Polynomial Fits to Determine Minimum Acceptable Burnup for A Type Assemblies Storage as a Function of Initial Enrichment Decay Time, Years Burnup, MWD/KgU 0
0.68
- E3 - 7.449
- E2 + 38.56
- E - 45.20 5
0.5489
- E3 - 5.9344
- E2 + 32.496
- E - 38.05 10 0.4153
- E3 - 4.3948
- E2 + 26.356
- E - 30.75 15 0.2867
- E3 - 2.9045
- E2 + 20.367
- E - 23.80 20 0.153
- E3 - 1.3649
- E2 + 14.227
- E - 16.60 Note: E = Initial average enrichment in wt% U-235
ARKANSAS - UNIT 2 3/4 9-21 Amendment No.
Figure 3.9-2 Table 2 Minimum Burnup Requirements for C Assemblies at Varying Enrichment and Cooling Time BURNUP, MWD/KgU Average Enrichment, wt% U-235 0 Years Cooling Time 5 Years Cooling Time 10 Years Cooling Time 15 Years Cooling Time 20 Years Cooling Time 2
17.00 15.00 14.00 13.30 13.00 2.5 25.00 22.00 21.00 20.30 20.00 3.0 32.00 29.00 27.00 26.00 25.00 3.5 37.00 35.00 32.50 31.00 30.00 4.0 43.00 40.00 39.00 38.00 37.00 4.5 49.75 46.00 45.00 44.00 43.00 Table 2-1 Bounding Polynomial Fits to Determine Minimum Acceptable Burnup for C Type Assemblies Storage as a Function of Initial Enrichment Decay Time, Years Burnup, MWD/KgU 0
1.3148
- E3 - 13.552
- E2 + 57.491
- E - 53.6 5
0.3704
- E3 - 4.5397
- E2 + 29.59
- E - 28.8 10 0.6667
- E3 - 6.5714
- E2 + 32.976
- E - 30.3 15 0.7111
- E3 - 6.919
- E2 + 33.634
- E - 31.3 20 0.8148
- E3 - 7.7302
- E2 + 35.169
- E - 32.0 Note: E = Initial average enrichment in wt% U-235
ARKANSAS - UNIT 2 5-2 Amendment No. 24,71,95,157,181,205, DESIGN FEATURES 5.3 Fuel Storage 5.3.1 Spent Fuel Storage Rack Criticality The spent fuel storage racks are designed and shall be maintained with:
- a.
Fuel assemblies stored in the spent fuel pool in accordance with Specification 3.9.12;
- b.
keff 0.95 if fully flooded with 240 ppm unborated water, which includes an allowance for uncertainties as described in Section 9.1 of the SAR; and
- c.
keff < 1.0 if fully flooded with unborated water, which includes an allowance for uncertainties as described in Section 9.1 of the SAR; and
- d.
A nominal 9.8 inch center to center distance between fuel assemblies placed in the storage racks.
5.3.2 New Fuel Storage Rack Criticality The new fuel storage racks are designed and shall be maintained with:
- a.
Fuel assemblies having a maximum U-235 enrichment of 5.04.55+/-0.05 weight percent;
- b.
keff 0.95 if fully flooded with unborated water, which includes an allowance for uncertainties as described in Section 9.1 of the SAR;
- c.
keff 0.98 if moderated by aqueous foam, which includes an allowance for uncertainties as described in Section 9.1 of the SAR; and
- d.
A nominal 26 inch center to center distance between fuel assemblies placed in the storage racks.
5.3.3 Drainage The spent fuel storage pool is designed and shall be maintained to prevent inadvertent draining of the pool below elevation 399' 101/2".
5.3.4 Capacity The spent fuel storage pool is designed and shall be maintained with a storage capacity limited to no more than 988 fuel assemblies.
2CAN060306 Changes to Technical Specification Bases Pages For Information Only
ARKANSAS - UNIT 2 B 3/4 9-3 Amendment No. 43,166,178,224,228, REFUELING OPERATIONS BASES 3/4.9.9 and 3/4.9.10 WATER LEVEL-REACTOR VESSEL AND SPENT FUEL POOL WATER LEVEL The restrictions on minimum water level ensure that sufficient water depth is available to remove 99% of the assumed 12% iodine gap activity released from the rupture of an irradiated fuel assembly. The minimum water depth is consistent with the assumptions of the accident analysis.
3/4.9.11 FUEL HANDLING AREA VENTILATION SYSTEM The limitations on the fuel handling area ventilation system ensure that all radioactive materials released from an irradiated fuel assembly will be filtered through the HEPA filters and charcoal adsorbers prior to discharge to the atmosphere. The operation of this system and the resulting iodine removal capacity are consistent with the assumptions of the accident analyses.
Acceptable removal efficiency is shown by methyl iodide penetration of less than 5.0% when tests are performed in accordance with ASTM D3803-1989, "Standard Test Method for Nuclear-Grade Activated Carbon," at a temperature of 30°C and a relative humidity of 95%. The penetration acceptance criterion is determined by the following equation:
Allowable = [100% - methyl iodide efficiency for charcoal credited in accident analysis]
Penetration safety factor of 2 Applying a safety factor of 2 is acceptable because ASTM D3803-1989 is a more accurate and demanding test than older tests.
3/4.9.12 FUEL STORAGE Region 1 and Region 2 of the The spent fuel storage racks are designed to assure that when fuel assemblies of less than or equal to 5.04.55+/-0.05 w/o U-235 enrichment that are stored are within the limits of Figure 3.9.2 will be maintained in a subcritical array with K eff 0.95 will be maintained when a concentration of 240 ppm of soluble boron is present in the spent fuel pool water.in unborated water. These conditions have been verified by criticality analyses.
The requirement for 1600 2000 ppm boron concentration is to assure the fuel assemblies will be maintained in a subcritical array with K eff 0.95 in the event of a postulated accident. Analysis has shown that, during a postulated accident with the fuel stored within the limits of this specification, that a Keff of 0.95 will be maintained when the boron concentration is at or above 1000 825 ppm.
Normally, fuel stored in a cross-hatch storage configuration must have all four diagonal spaces or at least two adjacent faces remain vacant to meet the criticality safety analysis mentioned above. However, the spent fuel pool walls may be credited as a neutron leakage path.
Therefore, vacant spaces face adjacent to the walls of the Region I cross-hatch configured assemblies may be used to store fuel assemblies that are outside of the area of the graph enclosed by Curve A on Figure 3.9.2, excluding the most southeast and southwest corner spaces of Region 1 which must remain empty.
The following restrictions apply to fuel assembly storage in the SFP:
ARKANSAS - UNIT 2 B 3/4 9-3 Amendment No. 43,166,178,224,228, Racks must be loaded using one of the five patterns shown in Figure 3.9-12. The type A and C assemblies have restrictions which are designated in Tables 1, 1-1, 2, and 2-1 of Figure 3.9-2. In any pattern, a less restrictive assembly may be substituted for another assembly within the pattern.
For adjacent patterns, both inside and between racks in the SFP, only the allowed interface configurations shown in Figure 3.9-2 may be used.
A minimum soluble boron concentration of 825 ppm must be maintained in the SFP to ensure that Keff is less than or equal to 0.95 under all credible accident conditions.
2CAN060306 List of Regulatory Commitments 2CAN060306 Page 1 of 1 List of Regulatory Commitments The following table identifies those actions committed to by Entergy in this document. Any other statements in this submittal are provided for information purposes and are not considered to be regulatory commitments.
TYPE (Check one)
COMMITMENT ONE-TIME ACTION CONTINUING COMPLIANCE SCHEDULED COMPLETION DATE (If Required)
The ANO-2 SAR will be amended no later than the next required update after the proposed TS change is approved and implemented. This SAR update will indicate that ANO-2 has chosen to comply with 50.68(b).
x 6 months after the end of the ANO-2 fall 2003 refueling outage.
2CAN060306 Holtec License Amendment Report
Project No. 1196 Report No. HI-2033026 Page 1 Table of Contents
1.0 INTRODUCTION
1 2.0
SUMMARY
OF CRITICALITY ANALYSES FOR NORMAL OPERATING CONDITIONS 4 3.0 REFERENCE DESIGN INPUT DATA 4 3.1 Reference Fuel Assembly Design 4 3.2 Region 1 Fuel Storage Cells. 5 3.3 Region 2 Fuel Storage Cells. 5 4.0 ANALYTICAL METHODOLOGY 5 4.1 Reference Design Calculations 5 4.2 Fuel Burnup Calculations.6 4.3 Effect of Axial Burnup Distribution 7 4.4 MCNP4a Temperature Correction 7 4.5 Long Term Changes in Reactivity 7 5.0 CRITICALITY ANALYSES.. 8 5.1 Nominal Design Case 8 5.2 Uncertainties Due to Tolerances. 8 5.3 Eccentric Fuel Positioning 9 5.4 Interface Calculations..
9 6.0 ABNORMAL AND ACCIDENT CONDITIONS IN THE SPENT FUEL POOL RACKS. 9 6.1 Temperature and Water Density Effects 9 6.2 Lateral Rack Movement 9 6.3 Abnormal Location of a Fuel Assembly. 10 6.4 Dropped Fuel Assembly 10 7.0 SOLUBLE BORON DILUTION EVALUATION 11 8.0 STORAGE RESTRICTIONS. 13 9.0 REFERENCE.. 13 Appendix A Criticality Benchmark Package
Project No. 1196 Report No. HI-2033026 Page 2 List of Tables 1.1 Assembly Types, Rank and Description. 15 2.1 Summary of the Criticality Evaluations for Each Pattern.. 16 2.2 Minimum Burnup Requirements for A Assemblies at Varying Enrichment and Cooling Times 17 2.3 Bounding Polynomial Fits to Determine Minimum Acceptable Burnup for A Type Assemblies Storage as a Function of Initial Enrichment. 18 2.4 Minimum Burnup Requirements for C Assemblies at Varying Enrichment and Cooling Times 19 2.5 Bounding Polynomial Fits to Determine Minimum Acceptable Burnup for C Type Assemblies Storage as a Function of Initial Enrichment 20 2.6 Required Soluble Boron Concentrations in the SFP Water 21 3.1 Fuel Assembly Specifications and Core Operating Parameters.
22 5.1 Manufacturing Tolerances.. 23 5.2a Reactivity Effects of Manufacturing Tolerances for Patterns 1 and 2.. 24 5.2b Reactivity Effect of Enrichment Tolerance for Pattern 2.... 25 5.2c Temperature Bias for Patterns 1 and 2..
26 5.3a Reactivity Effects of Manufacturing Tolerances for Patterns 3, 4, and 5 27 5.3b Reactivity Effect of Enrichment Tolerance for Patterns 1, 3, 4, and 5 27 5.3c Temperature Bias for Patterns 3, 4, and 5 27
Project No. 1196 Report No. HI-2033026 Page 3 List of Figures 1.1:
Loading Configurations for ANO-2 SFP 28 3.1:
A Cross-Sectional View of the Calculational Model Used for the Region 1 Rack Analysis.. 29 3.2:
A Cross-Sectional View of the Calculational Model Used for the Region 2 Rack Analysis.. 30 5.1a Pattern 1 and Pattern 2 Interface.. 31 5.1b Pattern 1 and Pattern 3 Interface. 31 5.1c Pattern 1 and Pattern 3 Interface, Alternate Configuration.
31 5.1d Pattern 1 and Pattern 4 Interface.. 31 5.1e Pattern 1 and Pattern 5 Interface. 32 5.1f Pattern 2 and Pattern 3 Interface. 32 5.1g Pattern 2 and Pattern 3 Interface, Alternate Configuration 32 5.1h Pattern 2 and Pattern 3 Interface, Alternate Configuration 32 5.1i Pattern 2 and Pattern 4 Interface. 33 5.1j Pattern 2 and Pattern 4 Interface, Alternate Configuration.
33 5.1k Pattern 2 and Pattern 5 Interface.. 33 5.1l Pattern 2 and Pattern 5 Interface, Alternate Configuration 33 5.1m Pattern 2 and Pattern 5 Interface, Alternate Configuration 34 5.1n Pattern 3 and Pattern 4 Interface. 34 5.1o Pattern 3 and Pattern 4 Interface, Alternate Configuration 34 5.1p Pattern 3 and Pattern 4 Interface, Alternate Configuration 34 5.1q Pattern 3 and Pattern 5 Interface. 35 5.1r Pattern 3 and Pattern 5 Interface, Alternate Arrangement.. 35 5.1s Pattern 3 and Pattern 5 Interface, Alternate Configuration 35 5.1t Pattern 3 and Pattern 5 Interface, Alternate Configuration..
35
Project No. 1196 Report No. HI-2033026 Page 4 5.1u Pattern 4 and Pattern 5 Interface..
36 5.1v Pattern 4 and Pattern 5 Interface, Alternate Configuration.
36 5.1w Pattern 4 and Pattern 5 Interface, Alternate Configuration.
36
Project No. 1196 Report No. HI-2033026 Page 5
1.0 INTRODUCTION
Arkansas Nuclear One, Unit 2 (ANO-2) operated by Entergy Operations and in commercial operation since 1980, is located approximately 70 miles northwest of Little Rock, Arkansas and about five miles west of Russellville, Arkansas. ANO-2 is a Combustion Engineering pressurized water reactor (PWR) with a licensed thermal power level of 3026 megawatts. The reactor core contains 177 fuel assemblies and the spent fuel pool (SFP) is licensed for the storage of 988 fuel assemblies.
The racks in the SFP of ANO-2 are free-standing and self supporting racks of Westinghouse design. The principal fabrication materials are ASTM A-240, Type 304 stainless steel for the structural members and shapes. "Boraflex", a product of BISCO (a division of Brand, Inc.) was originally used to augment reactivity control.
The SFP was designed to hold spent fuel assemblies (or rod cluster control assemblies) in underwater storage for long-term decay after their removal from the reactor core. The structure is seismic Category I, heavy walled, reinforced concrete pool, located on grade outside the containment structure. The interior of the pool is lined with stainless steel plate (Type 304L).
This report documents the criticality safety evaluation for the ANO Unit 2 Spent Fuel Pool (SFP) to support storage of spent and fresh fuel assemblies in various defined patterns in the racks. The ANO Unit 2 SFP contains both Region 1 and Region 2 style storage racks. Although the Region 1 racks contain Boraflex poison material, analysis has indicated that Boraflex has degraded below the original analytical assumptions. This evaluation is performed to qualify the spent fuel and fresh fuel storage in the racks from a criticality perspective taking no credit for the Boraflex neutron poison absorbers.
This analysis is used to qualify the existing racks for the existing spent fuel currently in the pool and in the core. Additionally, fresh fuel assemblies must be able to be stored in the pool racks during the reload. Credit is taken for the presence of soluble boron in the spent fuel pool, fuel burnup, cooling time and for the presence of control element assemblies (CEAs) in selected fuel assemblies. In order to achieve this objective, it is necessary to establish different patterns for assemblies with different reactivities. Five different fuel storage configurations (patterns) were established for use during the upcoming fall 2003 refueling outage and following refueling outages. Figure 1.1 shows each loading configuration pattern and Table 1.1 provides a description of each of the assembly types with its reactivity ranking. The significance of the reactivity ranking is to determine which assemblies can be replaced with other assembly types in a given pattern. As a rule, only a less reactive assembly may substitute a given assembly for a pattern to be valid (i.e. an assembly with a higher ranking can be substituted within a given pattern for an assembly with a lower ranking).
Pattern 1 is based on the Region 2 burnup/enrichment/cooling time curves generated when the A type assembly is used. Any less reactive assembly may be substituted for the A assemblies. Pattern 2 is a 2 x 2 Region 2 configuration with two fresh fuel assemblies and two empty cells. Pattern 3 is a 2 x 2 Region 2 configuration with one F assembly with 3 C type assemblies, which contain CEAs. Pattern 4 is a 2 x 2 Region 2
Project No. 1196 Report No. HI-2033026 Page 6 configuration with two fresh fuel assemblies, containing CEAs, and two C type assemblies. Pattern 5 is a 2 x 2 Region 2 configuration with one B assembly with 3 C type assemblies. The definitions for the A and C type spent fuel assemblies are determined using iterative processes, in terms of burnup, enrichment, and cooling time.
The analyses performed for the Region 2 racks and the burnup requirements determined for the storage of spent fuel assemblies in the Region 2 type racks are also applicable to the Region 1 type racks.
The racks are evaluated for Combustion Engineering (CE) 16x16 fresh and spent fuel assemblies. Credit is taken for control elements (CEAs), fuel burnup, cooling time, and soluble boron in pool water as applicable per 10 CFR 50.68.
The objective of this analysis is to ensure that, per 10 CFR 50.68, the racks shall remain subcritical under normal conditions with no credit for soluble boron and less than or equal to 0.95 when partial credit is taken for soluble boron in the pool water, including calculation uncertainties and reactivity effects of mechanical tolerances. Reactivity effects of abnormal and accident conditions have also been evaluated to determine the required soluble boron concentration in the pool to assure that under all credible abnormal and accident conditions, the reactivity will not exceed the regulatory limit of 0.95. The required soluble boron concentrations are summarized in Table 2.6. In this context "abnormal" refers to conditions, which may reasonably be expected to occur during the lifetime of the plant and "accident" refers to conditions, which are not expected to occur but nevertheless must be protected against. The double contingency principle of ANSI N-16.1-1975 and of the April 1978 NRC letter allows full credit for soluble boron under other abnormal or accident conditions, since only a single independent accident need be considered at one time.
Applicable codes, standards, and regulations or pertinent sections thereof, include the following:
Code of Federal Regulations, Title 10, Part 50, Appendix A, General Design Criterion 62, Prevention of Criticality in Fuel Storage and Handling.
Code of Federal Regulation 10CFR50.68, Criticality Accident Requirements.
USNRC Standard Review Plan, NUREG-0800, Section 9.1.2, Spent Fuel Storage, Rev. 3 - July 1981.
USNRC letter of April 14, 1978, to all Power Reactor Licensees - OT Position for Review and Acceptance of Spent Fuel Storage and Handling Applications, including modification letter dated January 18, 1979.
L. Kopp, Guidance on the Regulatory Requirements for Criticality Analysis of Fuel Storage at Light-Water Reactor Power Plants, NRC Memorandum from L.
Kopp to T. Collins, August 19, 1998.
USNRC Regulatory Guide 1.13, Spent Fuel Storage Facility Design Basis, Rev. 2 (proposed), December 1981.
Project No. 1196 Report No. HI-2033026 Page 7 ANSI ANS-8.17-1984, Criticality Safety Criteria for the Handling, Storage and Transportation of LWR Fuel Outside Reactors.
To assure the true reactivity will always be less than the calculated reactivity, the following conservative design criteria and assumptions were employed:
The Region 2 type racks, which are more reactive than the Region 1 racks, are used in the analyses. The burnup requirements determined the storage of spent fuel assemblies in the Region 2 type racks will also be applicable to the Region 1 type racks.
The effective multiplication factor (keff) of an infinite radial array of fuel assemblies or assembly patterns was used in the analyses, except for the assessment of peripheral and interface effects, and for certain abnormal/accident conditions where neutron leakage is inherent.
Minor structural materials were neglected; i.e., spacer grids were conservatively assumed to be replaced by water.
Because the temperature coefficient of reactivity is positive in the absence of neutron absorber panels, the analyses assumed a temperature of 150 °F. This is the design basis maximum pool water temperature. Higher temperatures would be an accident condition for which full soluble boron credit is permitted and the reactivity effects would be mitigated by the presence of the large amounts of soluble boron in the pool water.
No axial blankets were assumed to be present in the fuel rods. The entire active fuel length was assumed to be of uniform enrichment.
In-core depletion calculations assume conservative operating conditions, highest average fuel and moderator temperature, and an allowance for the average soluble boron concentrations during in-core operations.
Absorber rods present in some fuel assemblies are conservatively assumed to be fuel rods.
The densities of Boron Carbide (B4C) in the fuel rod and the Silver-Indium-Cadmium (Ag-In-Cd) tip absorbers are reduced by approximately 5% of nominal to conservatively account for burnout.
Project No. 1196 Report No. HI-2033026 Page 8 2.0
SUMMARY
OF CRITICALITY ANALYSES FOR NORMAL OPERATING CONDITIONS The criticality analyses for each of the five separate storage patterns are summarized in Table 2.1. For the acceptance criteria defined in the previous section, the maximum effective multiplication factor (keff) values are shown to be less than 1.0 (95% probability at the 95% confidence level) in each of the regions when no credit is taken for the presence of soluble boron in the pool. Credit for soluble boron is required to ensure keff is maintained less than 0.95 and the required soluble boron concentrations are summarized in Table 2.6.
The maximum keff values for storage of fuel assemblies, in the five different patterns, were determined assuming an infinite radial array of storage cells with a finite axial length, water reflected. For each spent fuel cooling time and initial enrichment, minimum burnup values were determined that assure the maximum keff, including calculational and manufacturing uncertainties, remains subcritical under the assumed accident condition of the loss of all soluble boron. The calculated maximum reactivity includes the reactivity effect of the axial distribution in burnup and provides an additional margin of uncertainty for the calculations. Table 2.1 summarizes the results of these analyses at zero cooling time for fresh fuel assemblies with an initial enrichment of 4.55 +/-0.05 wt% 235U and spent fuel assemblies with an initial enrichment of 4.50 +/-0.05 wt% 235U. The results show that the five storage patterns are acceptable for fuel storage.
Table 2.2 shows the minimum acceptable burnup for the A type assemblies. Table 2.3 provides the bounding polynomial fits to determine minimum acceptable burnup for A type assemblies as a function of initial enrichment. Table 2.4 shows the minimum acceptable burnup for the C type assemblies. Table 2.5 provides the bounding polynomial fits to determine minimum acceptable burnup for C type assemblies as a function of initial enrichment. Fuel assemblies with initial enrichments less than 2.0 wt%
235U will conservatively be required to meet the burnup requirements of 2.0 wt% 235U assemblies, which are reflected in Tables 2.2 and 2.4. The minimum soluble boron concentration required to maintain keff below 0.95 for normal storage of fresh and spent fuel assemblies, including all manufacturing and calculational tolerances, for the storage of spent fuel in the racks is 240 ppm.
3.0 REFERENCE DESIGN INPUT DATA 3.1 Reference Fuel Assembly Design The spent fuel storage racks are designed to accommodate Combustion Engineering (CE) 16x16 fuel assemblies. The design specifications for the CE fuel assemblies, as used for this analysis, are given in Table 3.1.
Project No. 1196 Report No. HI-2033026 Page 9 3.2 Region 1 Fuel Storage Cells Figure 3.1 shows the Region 1 spent fuel storage cell. The Region 1 storage cells are composed of stainless steel boxes separated by a gap. The 0.075+/-0.0040 inch thick steel walls define the storage cells, which have a 8.58 +0.050/-0.025 inch nominal inside dimension. A 0.020 inch stainless steel sheath is around the gap and defines the boundary of the flux-trap water-gap used to augment reactivity control. The cells are located on a lattice spacing of 9.80 inches in both directions. Stainless steel channels connect the storage cells in a rigid structure and define the flux-trap of 0.806 +/-0.010 inches, between the sheathing of adjacent cells.
3.3 Region 2 Fuel Storage Cells Figure 3.2 shows the Region 2 spent fuel storage cell. The Region 2 storage cells area also have a flux trap between adjacent cells and are composed of stainless steel boxes separated by a gap. The straight portion of the flux trap is 7.2 inches. The measured flux trap water gap of 0.97 +0.12/-0.08 inches was used in the analysis. The 0.075
+/-0.0040 thick steel walls define the storage cells, which have a 8.58 +0.050/-0.025 inch nominal inside dimension. The measured value of the flux trap water gap corresponded to a Box ID of 8.68 inches because of the bow in the cell walls. This value of the Box ID was used in the analysis. The cells are located on a lattice spacing of 9.80 inches in both directions. No additional water gaps exist between adjacent Region 2 cells in a rack.
4.0 ANALYTICAL METHODOLOGY 4.1 Reference Design Calculations The principal methods for the criticality analyses of the storage racks include the following codes: (1) MCNP4a [1], and (2) CASMO-4 [2-4]. MCNP4a is a continuous energy three-dimensional Monte Carlo code developed at the Los Alamos National Laboratory.
Benchmark calculations, presented in Appendix A, indicate a bias of 0.0009 with an uncertainty of +/-0.0011 for MCNP4a evaluated with the 95% probability at the 95%
confidence level [5].
Fuel depletion analyses during core operation were performed with CASMO-4, a two-dimensional multi-group transport theory code based on capture probabilities [2-4].
Restarting the CASMO-4 calculations in the storage rack geometry yields the two-dimensional infinite multiplication factor (k) for the storage rack. CASMO-4 was also used to determine the reactivity uncertainties (differential calculations) of manufacturing tolerances and the reactivity effects of variations in the water temperature and density.
In the geometric models used for the calculations, each fuel rod and its cladding were described explicitly and reflecting boundary conditions were used in the radial direction, which has the effect of creating an infinite radial array of storage cells. Three-dimensional MCNP calculations were necessary to describe the geometry of the 2 x 2 cases.
However, MCNP cannot perform depletion calculations, thus depletion calculations were performed with CASMO-4. Explicit description of the fission product nuclide concentrations in the spent fuel was determined from the CASMO-4 calculations and
Project No. 1196 Report No. HI-2033026 Page 10 used in the MCNP calculations. This methodology explicitly incorporates approximately 40 of the most important fission products, accounting for all but about 1% in k. The remaining ~1% in k was accounted for in one of two ways. For patterns 1 and 2, to compensate for the few fission product nuclides that are not in the MCNP library, an equivalent boron-10 concentration in the fuel was determined which produced the same reactivity in MCNP as the CASMO-4 result. For patterns 3, 4 and 5, appropriate cross-sections were used in MCNP to produce the same reactivity effect as in the results generated in CASMO-4.
The convergence of a Monte Carlo criticality problem is sensitive to the following parameters: (1) number of histories per cycle, (2) the number of cycles skipped before averaging, (3) the total number of cycles and (4) the initial source distribution. The MCNP4a criticality output contains a great deal of useful information that may be used to determine the acceptability of the problem convergence. This information has been used in parametric studies to develop appropriate values for the aforementioned criticality parameters to be used in storage rack criticality calculations. Based on these studies, the final calculations use a minimum of 10,000 histories per cycle, a minimum of 25 cycles were skipped before averaging, a minimum of 100 cycles were accumulated, and the initial source was specified as uniform over the fueled regions (assemblies).
4.2 Fuel Burnup Calculations and Uncertainties CASMO-4 was used for burnup calculations in the hot operating condition. To the extent possible, CASMO-4 has been benchmarked [3, 4] against cold, clean, critical experiments (including plutonium-bearing fuel) and also by comparison with Monte Carlo calculations.
In the CASMO-4 geometric models, each fuel rod and its cladding were described explicitly and reflective boundary conditions were used in the axial direction and between storage cells. These boundary conditions have the effect of creating an infinite array of storage cells in both the radial and axial directions.
Conservatively bounding moderator and fuel temperatures and the average core operating soluble boron concentrations (900ppm) were used to assure the highest plutonium production and hence conservatively high values of reactivity. Since critical experiment data with spent fuel is not available for determining the uncertainty in calculations, an allowance for uncertainty in reactivity was assigned based upon other considerations [6].
Calculations are performed to determine uncertainties for depletion for each of patterns 1, 3, 4, and 5. The depletion uncertainty is determined using two MCNP criticality calculations for each pattern. The reference case for each pattern is the case with the highest minimum spent fuel burnup requirement, which is the 4.50% initial enrichment, 0 year cooling time 49.75 GWD/MTU case. Then a new calculation is run where every assembly in the pattern is modeled as a fresh assembly (F or Fc). The assemblies that contain CEAs in the reference case will keep the CEAs in the depletion (fresh assembly) case. The depletion uncertainty is equal to 5% of the keff.
Project No. 1196 Report No. HI-2033026 Page 11 4.3 Effect of Axial Burnup Distribution Initially, fuel loaded into the reactor will burn with a slightly skewed cosine power distribution. As burnup progresses, the burnup distribution will tend to flatten, becoming more highly burned in the central regions than in the upper and lower regions. At high burnups, the more reactive fuel near the ends of the fuel assembly (less than average burnup) occurs in regions of high neutron leakage. Consequently, it is expected that over most of the burnup history, fuel assemblies with distributed burnups will exhibit a slightly lower reactivity than that calculated for the uniform average burnup. As burnup progresses, the distribution, to some extent, tends to be self-regulating as controlled by the axial power distribution, precluding the existence of large regions of significantly reduced burnup.
Among others, Turner [7] has provided generic analytic results of the axial burnup effect based upon calculated and measured axial burnup distributions. These analyses confirm the minor and generally negative reactivity effect of the axially distributed burnups at values less than about 30 GWD/MTU with small positive reactivity effects at higher burnup values.
Since the required burnup for some enrichments and cases is greater than 30 GWD/MTU, the reactivity effect of the axially distributed burnup must be considered.
These calculations were performed in MCNP4a with 10 zone axial calculations, using specific (CASMO-4) concentrations of actinides and fission product nuclides in each zone. For all patterns, the burnup level of higher reactivity was determined and the more conservative profile (flat or distributed) was used. Calculations were performed based upon a burnup distribution provided by ANO.
4.4 MCNP4a Temperature Correction The reactivity for non-poisoned racks in the spent fuel pool increases with pool water temperature. The maximum bulk pool water temperature is administratively controlled at ANO Unit 2 as 150 °F. However, since the Doppler treatment and cross-sections in MCNP4a are valid only at 20 °C, the ?k determined in CASMO-4 calculations from 20 °C to 150 °F is included as a bias in the final keff calculation.
4.5 Long-Term Changes in Reactivity At reactor shutdown, the reactivity of the fuel initially decreases due to the growth of Xe-135. Subsequently, the Xenon decays and the reactivity increases to a maximum at about a hundred hours after the Xenon has decayed. Therefore, for conservatism, the Xenon is set to zero in the calculations to assure maximum reactivity. During the next 50 years, the reactivity continuously decreases due primarily to 241Pu decay and 241Am growth. Credit for this decay and for changes in fission product concentration is included in calculations of the decrease in reactivity in long term storage (up to 20 years). The CASMO-4 code includes the capability of tracking the decay of the actinides and the most significant fission product nuclides during long term storage.
Project No. 1196 Report No. HI-2033026 Page 12 5.0 CRITICALITY ANALYSES 5.1 Nominal Design Case For the nominal storage cell design in Region 2, the criticality safety analyses for the five different storage patterns are summarized in Table 2.1. These data confirm that the maximum reactivity in all five storage patterns remain subcritical (less than the regulatory limit keff < 1.0) under the assumed condition of the loss of all soluble boron in the pool water. Tables 2.2 and 2.4 show the limiting burnup values for fuel of other enrichments and cooling times.
5.2 Uncertainties Due to Tolerances A listing of the tolerance values is given in Table 5.1. Base calculations are performed using nominal values of the rack dimensions and fuel density and initial enrichment of the fuel assemblies. The reactivity effects of the tolerances in fuel and rack dimensions and the fuel initial enrichments are determined in the analysis by performing sensitivity studies of the reactivity effects of the tolerance variations.
The reactivity effects of the rack manufacturing and fuel density tolerance uncertainties, except depletion tolerance, for pattern 1 and pattern 2 are shown in Table 5.2a. Table 5.2b shows the reactivity effects of fuel enrichment tolerance for pattern 1. The temperature bias was also calculated in CASMO-4 for patterns 1 and 2 and is shown in Table 5.2c.
Table 5.3a shows the reactivity effects of the rack manufacturing and fuel density tolerances for patterns 3, 4, and 5, which are statistically combined. Table 5.3b shows the reactivity effects of fuel enrichment tolerance for patterns 1, 3, 4 and 5. The temperature bias was also calculated in CASMO-4 for patterns 3, 4, and 5 and is shown in Table 5.3c.
Each of the reactivity effects shown in Table 5.2a-5.2c and 5.3a-5.3c is calculated, one at a time, with CASMO-4 by setting each tolerance at its most reactive value in a parametric study. All of the individual reactivity uncertainties are then combined using the standard conventional statistical methodology, i.e., square root of the sum of the squares of the independent uncertainties. The maximum keff for a storage pattern is then determined using the following formula:
Maximum keff = keff (reference) + biases + [i (UNCi)2] 1/2 where UNC values are the reactivity effects of individual uncertainties, each evaluated at the 95% probability, 95% confidence level or greater. Since each of the reactivity uncertainties are independently calculated at the 95% probability/ 95% confidence level (or greater), the final maximum keff is at the 95% probability/ 95% confidence level, in accordance with the specifications of the 1978 Grimes letter and the 1998 Kopp memorandum. The reactivity effects of the tolerances are also tabulated in Table 2.1.
Project No. 1196 Report No. HI-2033026 Page 13 5.3 Eccentric Fuel Positioning The fuel assemblies are assumed to be normally located in the center of the storage rack cell. However, for determining the reactivity effects of the eccentric positioning of the fuel assemblies, calculations were also made with the fuel assemblies assumed to be in the corner of the storage rack cell (four-assembly cluster at closest approach). The keff of each patterns eccentric positioning analysis is compared to the keff of the corresponding reference case and the uncertainty is set equal to the difference between the two. The uncertainty for eccentricity is included in the calculations for the final keff in Table 2.1.
5.4 Interface Calculations In these evaluations, interfaces between two different storage patterns placed adjacent to each other within a rack are analyzed. This conservatively bounds rack-to-rack interfaces for acceptable configurations since no credit is taken for the gap between racks. The interface configurations that are deemed unacceptable for storage within a rack will also be considered unacceptable for adjacent storage patterns between racks.
Figures 5.1a to 5.1w show each of the analyzed configurations.
6.0 ABNORMAL AND ACCIDENT CONDITIONS IN THE SPENT FUEL POOL RACKS 6.1 Temperature and Water Density Effects The moderator temperature coefficient of reactivity in both Region 1 and Region 2 is positive. Therefore, a moderator temperature of 20 °C (68 °F) was assumed for the reference MCNP4a calculations and the increase in reactivity to the maximum bulk pool water temperature of 150 °F is included (CASMO-4 calculation) as a bias in the calculation of the maximum keff. This assures that the true reactivity will always be lower over the expected range of water temperatures. The reactivity effects of the pool water temperature effects on reactivity have been evaluated using CASMO-4.
6.2 Lateral Rack Movement Lateral motion of the storage racks under postulated seismic conditions could potentially alter the spacing between racks. Under these conditions, credit for the soluble boron (permitted under accident conditions) would maintain the keff at a value well below the maximum allowable. Nevertheless, the separation (water-gap) between rack modules is sufficiently large that even for the maximum movement expected under seismic excitation, the water gap remains larger than the water gap within the Region 1 modules.
In the Region 2 racks, the keff is independent of the inter-module water gap and is not sensitive to any potential seismic induced movement of the modules. The water gap structure in each cell is included in the analysis and precludes any closer proximity between modules.
Project No. 1196 Report No. HI-2033026 Page 14 6.3 Abnormal Location of a Fuel Assembly The misplacement of a fresh unburned fuel assembly of the highest permissible reactivity could, in the absence of soluble poison, result in exceeding the regulatory limit (keff< 1.0).
This could occur if a fresh fuel assembly of the highest permissible initial enrichment (4.55
+/-0.05 wt% 235U) were to be inadvertently loaded into a Region 1 or Region 2 storage cell, which is intended to store spent fuel assemblies or remain empty. Calculations confirmed that the highest reactivity, including uncertainties, for the worst case postulated accident condition (fresh fuel assembly in Region 2 cell intended to remain empty) would exceed the limit on reactivity in the absence of soluble boron. Soluble boron in the spent fuel pool water, for which credit is permitted under these accident conditions, would assure that the reactivity is maintained substantially less than the design limitation. Calculations indicate that a soluble boron concentration of 825 ppm is adequate, under accident conditions, to assure that the maximum keff does not exceed 0.95. Proposed ANO-2 Technical Specifications will require that a concentration of at least 2000 ppm boron is maintained in the SFP.
There is also no opportunity for an accidental drop of a fuel assembly outside and adjacent to the racks in the rack-to-rack gaps because there is insufficient clearance between the racks. Accidental placement of a fuel assembly between the racks and the spent fuel pool walls is bounded by the internal misplacement of fuel assemblies. This is an area of high neutron leakage and the reactivity effect would be bounded by that of a fuel assembly accidentally mis-loaded internal to a rack.
6.4 Dropped Fuel Assembly For the case in which a fuel assembly is assumed to be dropped on top of a rack and the fuel assembly comes to rest horizontally on top of the rack the minimum separation distance between the active fuel regions is more than 12 inches, which is sufficient to preclude neutron coupling (with fuel in the storage rack). Consequently, the horizontal fuel assembly drop accident will not result in a significant increase in reactivity.
Furthermore, the soluble boron in the spent fuel pool water assures that the true reactivity is always less than the limiting value for this dropped fuel accident.
It is also possible to vertically drop an assembly into a location occupied by another assembly. Such a vertical impact, would, at most cause a small compression of the stored assembly, reducing the water-to-fuel ratio and thereby reducing reactivity. In addition the distance between the active fuel regions of both assemblies will be more than sufficient to ensure no neutron interaction between the two assemblies.
Dropping of an assembly into an unoccupied cell could result in a localized deformation of the base plate of the rack. The immediate eight surrounding fuel cells could also be affected. However, the amount of deformation for these cells would be considerably less.
The resultant effect would be the lowering of a few fuel assemblies in the area near the deformation. The presence of the required soluble Boron concentration of 2000 ppm in the pool water assures the maximum keff is well below the 0.95 acceptance criteria.
Project No. 1196 Report No. HI-2033026 Page 15 7.0 SOLUBLE BORON DILUTION EVALUATION The soluble boron in the spent fuel pool water is normally a minimum of 2000 ppm under operating conditions. Significant loss or dilution of the soluble boron concentration is extremely unlikely, if not incredible. Nonetheless, an evaluation was performed based on the ANO-2 spent fuel pool data. The minimum required soluble boron concentration in the spent fuel pool water for various conditions are summarized in Table 2.6.
The required minimum soluble boron concentration is 240 ppm under normal conditions and 825 ppm for the most serious credible accident scenario. The volume of water in the pool is 199,200 gallons. Large amounts of unborated water would be necessary to reduce the boron concentration from 2000 ppm to 825 ppm or 240 ppm. Abnormal or accident conditions are discussed below for either low dilution rates (abnormal conditions) or high dilution rates (accident conditions). It should be noted that routine surveillances to measure the soluble boron concentrations in the pool water are required by Technical Specifications.
Small failures or mis-aligned valves could possibly occur in the normal soluble boron control system or related systems. Such failures might not be immediately detected.
These flow rates would be of the order of 2 gpm (comparable to normal evaporative loss) and the increased frequency of makeup flow might not be observed. However, an assumed loss flow-rate of 2 gpm dilutions flow rate would require 146 days to reduce the boron concentration to the minimum required 240 ppm required under normal conditions or 61 days to reach the 825 ppm required for the most severe fuel handling accident.
Routine surveillance measurements of the soluble boron concentration would readily detect the reduction in soluble boron concentration with ample time for corrective action.
Under certain accident conditions, it is conceivable that a high flow rate of unborated water could flow onto the top of the pool. Such an accident scenario could result from rupture of an unborated water supply line or possibly the rupture of a fire protection system header, both events potentially allowing unborated water to spray onto the pool.
A flow rate of up to 2500 gpm could possibly flow onto the spent fuel pool as a result of a rupture of the fire protection line. This would be the most serious condition and bounds all other accident scenarios. Conservatively assuming that all the unborated water from the break poured onto the top of the pool and further assuming instantaneous mixing of the unborated water with the pool water, it would take approximately 169 minutes to dilute the soluble boron concentration to 240 ppm, which is the minimum required concentration to maintain keff below 0.95 under normally operating conditions. In this dilution accident, approximately 422,000 gallons of water would spill on the auxiliary building floor and into the air-conditioning duct system. Well before the spilling of such a large volume of water, multiple alarms would have alerted the control room of the accident consequences (including the fuel pool high-level alarm, the fire protection system pump operation alarm, and the floor drain receiving tank high level alarm). For this high flow rate condition, 71 minutes would be required to reach the 825 ppm required for the most severe fuel handling accident.
A flow rate of 9.5 gallons per minute (gpm) would be required to dilute the soluble boron concentration to 240 ppm in 31 days and a total volume loss of approximately 422,000 gallons. Administrative controls require a measurement of the soluble boron concentration in the pool water at least weekly. Thus, the longest time period that a
Project No. 1196 Report No. HI-2033026 Page 16 potential boron dilution might exist without a direct measurement of the boron concentration is 7 days. In this time period, an undetected dilution flow rate of 30.6 gpm would be required to reduce the boron concentration to 825 ppm. No known dilution rate of this magnitude has been identified. Furthermore, a total of more than 300,000 gallons of unborated water would be associated with this dilution event and such a large flow of unborated water would be readily evident by high-level alarms and by visual inspection during daily walk-downs of the storage pool area.
For the fire control line break, upon the initial break, the fire protection system header pressure would drop to the auto start setpoint of the fire protection pumps. The start is accompanied with an alarm in the main control room. The annunciator response is to dispatch an operator to find the source of the pump start. Approximately 5 minutes into the event, a Spent Fuel Pool high level alarm would be received in the main control room, assuming that the Spent Fuel Pool level started at the low alarm. The annunciator response for high Spent Fuel Pool level is to investigate the cause. The coincidence of the 2 alarms would quickly lead to the discovery of the failure of the fire protection system and sufficient time to isolate the failure.
The analysis assume that for a double-ended break in the fire control piping, the stream of water will arch through the air some 40 feet falling on top of the pool. This is virtually an incredible event. Should the stream of water fall upon the pool deck, a 3 inch high curb would channel some of the water to the pool drain and prevent all of the water from reaching the pool. Furthermore, the evaluation also assumes at least 3 independent and concurrent accidents occur simultaneously:
Large amount of water flowing from the double-ended pipe break would remain un-detected and is ignored.
Pool water high level alarms either fail or are ignored.
Alarms indicating large amounts of water flowing into the floor drain have failed or are ignored.
It is not considered credible that multiple alarms would fail or be ignored or that the spilling of large volumes of water would not be observed. Therefore, such a major failure would be detected in sufficient time for corrective action to avoid violation of an administrative guideline and to assure that the health and safety of the public is protected.
The maximum flow rate for a failure of the demineralized water header would provide approximately 400 gpm into the Spent Fuel Pool. Failure of the demineralized water header is not accompanied with an alarm; however, the time to dilute the Spent Fuel Pool from 2000 ppm to 240 ppm is greater than the bounding case described above. In this scenario, there is sufficient time to isolate the failure and to prevent the spilling of some 320,000 gallons of water.
Instantaneous mixing of pool water with the water from the rupture of the demineralized water supply line is an extremely conservative assumption. Water falling on to the pool surface would mix with the top layers of pool water and the portions of the mixed volumes would continuously spill out of the pool. The density difference between water
Project No. 1196 Report No. HI-2033026 Page 17 at 150 °F (maximum permissible pool bulk water temperature) and at the temperature of the demineralizer water supply is small. This density difference will not cause the water falling on to the pool surface to instantaneously sink down into the racks overcoming the principal driving force for the flow in the pool, which is the buoyancy force generated in the spent fuel pool racks region due to the heat generation from the spent fuel in the racks. This would further enhance the mixing process between the pool water and spilled water above the racks.
8.0 STORAGE RESTRICTIONS A criticality safety evaluation has been performed for the ANO Unit 2 SFP to support the fall 2003 refueling outage and subsequent refueling outages using the existing racks without credit for Boraflex. The following restrictions apply:
Racks must be loaded using one of the 5 patterns shown in Figure 1.1, following the assembly description in Table 1.1. The A and the C assemblies are defined by burnup/enrichment curves shown in Tables 2.3 and 2.5. In any pattern, only a less reactive assembly (as dictated by the ranking in Table 1.1) may be substituted for another assembly within a pattern.
AND For adjacent patterns both inside and between racks in the SFP, only allowed interface configurations shown in figures 5.1a to 5.1w of this report may be used.
AND A minimum soluble boron level of 825 ppm must be maintained in the SFP to ensure that the effective neutron multiplication factor (keff) is less than or equal to 0.95 under all credible accident conditions.
9.0 REFERENCES
- 1. J.F. Briesmeister, Editor, MCNP - A General Monte Carlo N-Particle Transport Code, Version 4A, LA-12625, Los Alamos National Laboratory (1993).
- 2. M. Edenius, K. Ekberg, B.H. Forssén, and D. Knott, CASMO-4 A Fuel Assembly Burnup Program Users Manual, Studsvik/SOA-95/1, Studsvik of America, Inc. and Studsvik Core Analysis AB (proprietary).
- 3. D. Knott, CASMO-4 Benchmark Against Critical Experiments, SOA-94/13, Studsvik of America, Inc., (proprietary).
- 4. D. Knott, CASMO-4 Benchmark Against MCNP, SOA-94/12, Studsvik of America, Inc., (proprietary).
- 5. M.G. Natrella, Experimental Statistics, National Bureau of Standards, Handbook 91, August 1963.
Project No. 1196 Report No. HI-2033026 Page 18
- 6. L.I. Kopp, Guidance on the Regulatory Requirements for Criticality Analysis of Fuel Storage at Light-Water Reactor Power Plants, NRC Memorandum from L. Kopp to T. Collins, August 19, 1998.
- 7. S.E. Turner, "Uncertainty Analysis - Burnup Distributions", presented at the DOE/SANDIA Technical Meeting on Fuel Burnup Credit, Special Session, ANS/ENS Conference, Washington, D.C., November 2, 1988.
Project No. 1196 Report No. HI-2033026 Page 19 Table 1.1 Assembly Types, Rank and Description Rank Assembly Description 1
F Fresh Fuel, 4.55+/- 0.05 wt% U-235 2
B 4.1% maximum enrichment, 11.3 GWD/MTU minimum burnup, 0 years cooling time. Low burnup, typically one cycle. Does not meet the burnup requirements from Tables 2.2 and 2.4.
3 Fc Fresh 4.55+/-0.05 wt% fuel with a new CEA (Note 1) inserted 4
A An assembly that meets the minimum burnup requirements as defined in Tables 2.2 and 2.3.
5 BC A B type assembly with a CEA inserted (Note 2) 6 C
High burnup fuel, as defined in Tables 2.4 and 2.5.
7 AC An A type assembly with a CEA inserted (Note 2) 8 CC A C type assembly with a CEA inserted (Note 2) 9 X
Water cell, no fuel.
Note 1 - current CEA means the new CEA type. The old CEAs have a slightly different design.
Note 2 - The BC, AC, and CC types may have either CEA design inserted.
Project No. 1196 Report No. HI-2033026 Page 20 Table 2.1 Summary of the Criticality Evaluations for Each Pattern Pattern 1 Pattern 2*
Pattern 3 Pattern 4 Pattern 5 Reference keff 0.9706 0.9151 0.9758 0.9742 0.9706 MCNP4a Bias 0.0009 0.0009 0.0009 0.0009 0.0009 Temperature Effect Bias 0.0092 0.0101 0.0094 0.0094 0.0094 MCNP4a Bias Uncertainty 0.0011 0.0011 0.0011 0.0011 0.0011 MCNP4a Statistics (95/95) Uncertainty 0.0007 0.0007 0.0007 0.0007 0.0007 Manufacturing Tolerance Uncertainty 0.0097 0.0129 0.0096 0.0096 0.0096 Enrichment Tolerance Uncertainty 0.0033 0.0019 0.0033 0.0033 0.0033 Depletion Uncertainty 0.0136 N/A 0.0070 0.0092 0.0136 Fuel Eccentric Positioning Uncertainty 0.0021 0.0002 0.0010 0.0010 0.0022 Statistical Combination of Uncertainties 0.0172 0.0131 0.0124 0.0138 0.0171 Total keff 0.9979 0.9392 0.9985 0.9983 0.9980
- This pattern was conservatively analyzed at a fresh fuel enrichment of 4.95+/- 0.05 wt%.
Project No. 1196 Report No. HI-2033026 Page 21 Table 2.2 Minimum Burnup Requirements for A Assemblies at Varying Enrichment and Cooling Times BURNUP, MWD/KgU Average Enrichment, wt% 235U 0 Years Cooling Time 5 Years Cooling Time 10 Years Cooling Time 15 Years Cooling Time 20 Years Cooling Time 2
7.56 7.56 7.56 7.56 7.56 2.5 14.94 14.21 13.47 12.74 12.00 3.0 21.30 20.30 19.30 18.30 17.30 3.5 27.10 25.95 24.80 23.65 22.50 4.0 32.67 31.38 30.09 28.79 27.50 4.5 39.30 37.73 36.15 34.58 33.00 4.95 45.00 43.33 41.65 39.98 38.30
Project No. 1196 Report No. HI-2033026 Page 22 Table 2.3 Bounding Polynomial Fits to Determine Minimum Acceptable Burnup for A Type Assemblies Storage as a Function of Initial Enrichment Decay Time, Years Burnup, MWD/KgU 0
0.68*E3 - 7.449*E2 + 38.56*E - 45.20 5
0.5489*E3 - 5.9344*E2 + 32.496*E - 38.05 10 0.4153*E3 - 4.3948*E2 +26.356*E - 30.75 15 0.2867*E3 - 2.9045*E2 +20.367*E - 23.80 20 0.153*E3 - 1.3649*E2 +14.227*E - 16.60 Note: E = Initial average enrichment in wt% 235U
Project No. 1196 Report No. HI-2033026 Page 23 Table 2.4 Minimum Burnup Requirements for C Assemblies at Varying Enrichment and Cooling Times.
BURNUP, GWD/MTU Enrichment, wt% U235 0 Years Cooling Time 5 Years Cooling Time 10 Years Cooling Time 15 Years Cooling Time 20 Years Cooling Time 2
17.00 15.00 14.00 13.30 13.00 2.5 25.00 22.00 21.00 20.30 20.00 3
32.00 29.00 27.00 26.00 25.00 3.5 37.00 35.00 32.50 31.00 30.00 4
43.00 40.00 39.00 38.00 37.00 4.5 49.75 46.00 45.00 44.00 43.00
Project No. 1196 Report No. HI-2033026 Page 24 Table 2.5 Bounding Polynomial Fits to Determine Minimum Acceptable Burnup for C Type Assemblies Storage as a Function of Initial Enrichment.
Decay Time, Years Burnup, MWD/KgU 0
1.3148*E3 - 13.552*E2 + 57.491*E - 53.6 5
0.3704*E3 - 4.5397*E2 + 29.59*E - 28.8 10 0.6667*E3-6.5714*E2 +32.976*E - 30.3 15 0.7111*E3 - 6.919*E2 +33.634*E - 31.3 20 0.8148*E3 -7.7302*E2 +35.169*E - 32.0 Note: E = Initial average enrichment in wt% 235U.
Project No. 1196 Report No. HI-2033026 Page 25 Table 2.6 Required Soluble Boron Concentrations in the SFP Water Condition Soluble Boron Required for k<1 Soluble Boron Required for k<0.95 (ppm)
Normal Storage of Fresh and Spent Fuel Assemblies 0
240 Accident condition of 1 fresh fuel assembly mis-placed into a cell intended to remain empty 825
Project No. 1196 Report No. HI-2033026 Page 26 Table 3.1 Fuel Assembly Specifications and Core Operating Parameters Assembly Data Rod Array Size 16x16 Rod Pitch (inches) 0.506 Total Width (inches) 8.130-8.149 Total Length (inches) 176.803 Active Fuel Length (inches) 149.61-150 Fuel Rod Data Total Number of Fueled Rods Up to 236 Fuel Rod Total Length (inches) 161.318-161.868 Fuel Rod Outer Diameter (inches) 0.382 Fuel Rod Inner Diameter (inches) 0.332 Cladding Thickness (inches) 0.025 Cladding Material Zircaloy Pellet Diameter (inches) 0.325 UO2 Stack Density, gms/cc 10.522 Guide Tube Data Number of Tubes 5
Tube Outer Diameter (inches) 0.980 Tube Thickness (inches) 0.040 Tube Material Zircaloy
Project No. 1196 Report No. HI-2033026 Page 27 Table 5.1 Manufacturing Tolerances Data Value Box I.D.
See Figures 3.1 and 3.2 Box Wall Thickness
+/-0.004 inches SS Sheath Thickness
+/-0.004 inches Water Gap (Region 1)
+/-0.01 inches Water Gap (Regions 2)
+/-0.08 inches
Project No. 1196 Report No. HI-2033026 Page 28 Table 5.2a Reactivity Effects of Manufacturing Tolerances for Patterns 1 and 2
- Burnup, GWD/MtU Referenc e
Minimum Box ID Min. Water Gap Min. Box Wall Thickness Fuel Density Statistical Sum kinf kinf k
kinf k
kinf k
kinf k
0 1.2722 1.2759 0.003 7
1.2837 0.0115 1.276 8
0.0046 1.2728 0.0006 0.0129 10 1.1867 1.1901 0.003 4
1.1973 0.0106 1.191 1
0.0044 1.1872 0.0005 0.0120 20 1.1198 1.1230 0.003 2
1.1296 0.0098 1.124 0
0.0042 1.1203 0.0005 0.0111 30 1.0578 1.0608 0.003 0
1.0670 0.0092 1.061 8
0.0040 1.0585 0.0007 0.0105 40 0.9976 1.0004 0.002 8
1.0063 0.0087 1.001 4
0.0038 0.9987 0.0011 0.0100 50 0.9396 0.9422 0.002 6
0.9478 0.0082 0.943 2
0.0036 0.9411 0.0015 0.0094
Project No. 1196 Report No. HI-2033026 Page 29 Table 5.2b Reactivity Effect of Enrichment Tolerance for Pattern 2
- BURNUP, GWD/MTU REFERENCE ENRICHMENT TOLERANCE kinf kinf
?k 0
1.2621 1.2640 0.0019 35 1.0187 1.0217 0.0030 37 1.0065 1.0095 0.0030 39 0.9945 0.9975 0.0030 41 0.9825 0.9856 0.0031 43 0.9706 0.9737 0.0031
Project No. 1196 Report No. HI-2033026 Page 30 Table 5.2c Temperature Bias for Patterns 1 and 2
- BURNUP, GWD/MTU T = 20 0C T = 150 0F kinf kinf
?k 0
1.2621 1.2722 0.0101 10 1.1780 1.1868 0.0088 20 1.1113 1.1198 0.0085 30 1.0491 1.0578 0.0087 40 0.9887 0.9977 0.0090 50 0.9302 0.9396 0.0094
Project No. 1196 Report No. HI-2033026 Page 31 Table 5.3a Reactivity Effects of Manufacturing Tolerances for Patterns 3, 4, and 5 Reference Minimum Box Id Min. Box Wall Thickness Min. Water Gap Fuel Density Statistical Sum kinf kinf k
kinf k
kinf k
kinf k
0.8988 0.9013 0.0025 0.9022 0.0034 0.9072 0.0084 0.9005 0.0017 0.0096 Table 5.3b Reactivity Effect of Enrichment Tolerance for Patterns 1, 3, 4, and 5 4.5 wt %
4.55 wt %
kinf kinf k
0.8988 0.9021 0.0033 Table 5.3c Temperature Bias for Patterns 3, 4, and 5 T = 20 0C T = 150 0F kinf kinf k
0.8988 0.9082 0.0094
Project No. 1196 Report No. HI-2033026 Page 32 Pa Pattern 1 Pattern2 Pattern 3 Pattern 4 Pattern 5 Figure 1.1:
Loading Configurations for ANO-2 SFP.
(Alternate arrangements of these patterns, as applicable to the interfaces between patterns, are shown in Figures 5.1a to 5.1w.)
BC or A BC or A BC or A BC or A F
X X
F F
C Fc B
C C
C
Project No. 1196 Report No. HI-2033026 Page 33 Figure 3.1:
A Cross-Sectional View of the Calculational Model Used for the Region 1 Rack Analysis (NOT TO SCALE).
0.806 in. Water Gap 8.58 +0.050/-0.025 inches sq.
9.80 Pitch Reference 0.020 +0.004 0.112 +0.010 0.075 +0.004
Project No. 1196 Report No. HI-2033026 Page 34 Figure 3.2:
A Cross-Sectional View of the Calculational Model Used for the Region 2 Rack Analysis (NOT TO SCALE).
Note: In order to preserve the pitch due to a conservative reduction of the flux trap gap width from a design reference value of 1.07 inches to 0.97 inches (based on measurements), the cell ID was modeled as 8.68+0.050/-0.025inches.
50o 20 9.80 inch Pitch 0.97 +0.12/-0.08 0.075 + 0.004 7.2 Note: All dimensions, unless otherwise noted, are in inches.
8.58 +0.050/-0.025 sq.
Project No. 1196 Report No. HI-2033026 Page 35 A
A F
X A
A X
F Figure 5.1a: Pattern 1 and Pattern 2 Interface.
(This configuration is acceptable)
A A
F CC A
A CC CC Figure 5.1b: Pattern 1 and Pattern 3 Interface.
(This configuration is unacceptable)
A A
CC F
A A
CC CC Figure 5.1c: Pattern 1 and Pattern 3 Interface, Alternate Configuration.
(This configuration is acceptable)
A A
Fc C
A A
C Fc Figure 5.1d: Pattern 1 and Pattern 4 Interface.
(This configuration is acceptable)
Project No. 1196 Report No. HI-2033026 Page 36 A
A B
C A
A C
C Figure 5.1e: Pattern 1 and Pattern 5 Interface.
(This configuration is acceptable)
X F
F CC F
X CC CC Figure 5.1f:
Pattern 2 and Pattern 3 Interface.
(This configuration is unacceptable)
X F
CC CC F
X F
CC Figure 5.1g: Pattern 2 and Pattern 3 Interface, Alternate Configuration.
(This configuration is acceptable)
X F
CC F
F X
CC CC Figure 5.1h: Pattern 2 and Pattern 3 Interface, Alternate Configuration.
(This configuration is acceptable)
Project No. 1196 Report No. HI-2033026 Page 37 X
F Fc C
F X
C Fc Figure 5.1i:
Pattern 2 and Pattern 4 Interface.
(This configuration is acceptable)
X F
C Fc F
X Fc C
Figure 5.1j:
Pattern 2 and Pattern 4 Interface, Alternate Configuration.
(This configuration is acceptable)
X F
C C
F X
B C
Figure 5.1k: Pattern 2 and Pattern 5 Interface.
(This configuration is acceptable)
X F
B C
F X
C C
Figure 5.1l:
Pattern 2 and Pattern 5 Interface, Alternate Configuration.
(This configuration is acceptable)
Project No. 1196 Report No. HI-2033026 Page 38 X
F C
B F
X C
C Figure 5.1m: Pattern 2 and Pattern 5 Interface, Alternate Configuration.
(This configuration is acceptable)
CC F
Fc C
CC CC C
Fc Figure 5.1n: Pattern 3 and Pattern 4 Interface.
(This configuration is unacceptable)
CC CC Fc C
CC F
C Fc Figure 5.1o: Pattern 3 and Pattern 4 Interface, Alternate Configuration.
(This configuration is unacceptable)
F CC Fc C
CC CC C
Fc Figure 5.1p: Pattern 3 and Pattern 4 Interface, Alternate Configuration.
(This configuration is acceptable)
Project No. 1196 Report No. HI-2033026 Page 39 CC F
B C
CC CC C
C Figure 5.1q: Pattern 3 and Pattern 5 Interface.
(This configuration is unacceptable)
CC F
C C
CC CC B
C Figure 5.1r:
Pattern 3 and Pattern 5 Interface, Alternate Arrangement.
(This configuration is unacceptable)
CC F
C B
CC CC C
C Figure 5.1s: Pattern 3 and Pattern 5 Interface, Alternate Configuration.
(This configuration is unacceptable)
F CC C
C CC CC B
C Figure 5.1t:
Pattern 3 and Pattern 5 Interface, Alternate Configuration.
(This configuration is acceptable)
Project No. 1196 Report No. HI-2033026 Page 40 C
Fc C
C Fc C
C B
Figure 5.1u: Pattern 4 and Pattern 5 Interface.
(This configuration is acceptable)
C Fc B
C Fc C
C C
Figure 5.1v: Pattern 4 and Pattern 5 Interface, Alternate Configuration.
(This configuration is acceptable)
C Fc C
C Fc C
B C
Figure 5.1w: Pattern 4 and Pattern 5 Interface, Alternate Configuration.
(This configuration is acceptable)
Project No. 1196 Report No. HI-2033026 Page A-1 Appendix A: Criticality Benchmark Package (Total 25 Pages Including This Cover Page)
Note: This appendix was taken from a different report. Hence, the next page is labeled Appendix 4A, Page 1.