Letter Sequence Approval |
---|
EPID:L-2022-LLA-0161, Application to Remove Technical Specification Condition Allowing Two Reactor Coolant Pump Operation (Approved, Closed) |
|
MONTHYEAR1CAN102202, Application to Remove Technical Specification Condition Allowing Two Reactor Coolant Pump Operation2022-10-31031 October 2022 Application to Remove Technical Specification Condition Allowing Two Reactor Coolant Pump Operation Project stage: Request ML22341A1202022-12-0707 December 2022 NRR E-mail Capture - ANO Unit 1 - Acceptance of Requested Licensing Action LAR to to Remove Technical Specification Condition Allowing Two Reactor Coolant Pump Operation (L-2022-LLA-0161) Project stage: Acceptance Review ML23020A9362023-01-27027 January 2023 Audit Plan to Support Review of License Amendment Request to Remove Technical Specification Condition Allowing Two Reactor Coolant Pump Operation Project stage: Other ML23188A1732023-07-12012 July 2023 Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance ML23208A2132023-08-0303 August 2023 Regulatory Audit Summary Concerning Review of License Amendment Request to Remove Technical Specification Condition Allowing Two Reactor Coolant Pump Operation Project stage: Approval ML23275A2072023-11-28028 November 2023 Issuance of Amendment No. 280 Removal of Technical Specification Condition Allowing Two Reactor Coolant Pump Operation Project stage: Approval 2023-01-27
[Table View] |
|
---|
Category:Audit Report
MONTHYEARML23305A0922023-12-0707 December 2023 Summary of Regulatory Audit Regarding License Amendment Request to Revise Technical Specifications to Adopt TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times RITSTF Initiative 4b ML23208A2132023-08-0303 August 2023 Regulatory Audit Summary Concerning Review of License Amendment Request to Remove Technical Specification Condition Allowing Two Reactor Coolant Pump Operation ML23114A3572023-05-10010 May 2023 Regulatory Audit Summary Concerning Review of Request for Alternative ANO-CISI-002 Regarding Containment Inservice Inspection Frequency ML22174A3342022-07-12012 July 2022 Regulatory Audit Summary Concerning License Amendment Request for Technical Specification Changes Due to Revised Dose Calculations ML22011A1462022-01-24024 January 2022 Audit Summary for LARs to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors ML20288A8242020-11-16016 November 2020 Regulatory Audit Summary Concerning License Amendment Request to Replace the Reactor Building Spray Sodium Hydroxide Additive with a Passive Reactor Building Sump Buffering Agent ML15236A3402015-09-0101 September 2015 Report for the Audit Regarding Implementation of Mitigating Strategies and Reliable Spent Fuel Pool Instrumentation Related to Orders EA-12-049 and EA-12-051 ML14357A2592015-01-15015 January 2015 Audit of Licensee'S Management of Regulatory Commitments, Audit Performed October 14-16, 2014 ML1114606042011-09-30030 September 2011 Audit of the Licensee'S Management of Regulatory Commitments - Audit Performed on May 3 and 4, 2011 ML0827307772008-10-0808 October 2008 Audit of Entergy Operations, Inc. Management of Regulatory Commitments (TAC Nos. MD96665 and MD9666) ML0422400842004-07-29029 July 2004 Audit and Review Report for Plant Aging Management Reviews and Programs at the Arkansas Nuclear One Nuclear Power Plant, Unit 2 ML0419100502004-07-0606 July 2004 7/6/04, ANO1 - Arkansas Nuclear One, Units 1 and 2 - Audit of the Licensee'S Management of Regulatory Commitments 2023-08-03
[Table view] Category:Letter
MONTHYEARML23326A0392024-01-24024 January 2024 Issuance of Amendment No. 281 Revision to Technical Specifications to Adopt TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b ML24017A1582024-01-17017 January 2024 Submittal of Emergency Plan Revision 50 IR 05000313/20234202024-01-10010 January 2024 Security Baseline Inspection Report 05000313/2023420 and 05000368/2023420 IR 05000313/20234022024-01-0202 January 2024 Security Baseline Inspection Report 05000313/2023402 and 05000368/2023402 ML23354A0022023-12-21021 December 2023 Request for Withholding Information from Public Disclosure ML23349A1672023-12-21021 December 2023 Request for Withholding Information from Public Disclosure ML23348A3572023-12-14014 December 2023 Application to Revise Technical Specifications to Use Online Monitoring Methodology Slides and Affidavit for Pre-Submittal Meeting ML23352A0292023-12-13013 December 2023 Entergy - 2024 Nuclear Energy Liability Evidence of Financial Protection ML23340A1592023-12-13013 December 2023 Entergy Operations, Inc. - Entergy Fleet Project Manager Assignment IR 05000313/20234052023-12-12012 December 2023 Security Baseline Inspection Report 05000313/2023405 and 05000368/2023405 ML23341A0832023-12-11011 December 2023 Material Control and Accounting Program Inspection Report 05000313/368/2023404- Cover Letter ML23305A0922023-12-0707 December 2023 Summary of Regulatory Audit Regarding License Amendment Request to Revise Technical Specifications to Adopt TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times RITSTF Initiative 4b ML23333A1362023-11-29029 November 2023 Supplement to Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation ML23275A2072023-11-28028 November 2023 Issuance of Amendment No. 280 Removal of Technical Specification Condition Allowing Two Reactor Coolant Pump Operation ML23325A1412023-11-21021 November 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation IR 05000313/20230032023-11-21021 November 2023 Revised - ANO Revised Integrated Inspection Report 05000313/2023003 and 05000368/2023003 and Independent Spent Fuel Storage Installation Inspection Report 07200013/ 2023001 ML23243B0452023-11-13013 November 2023 Request for Withholding Information from Public Disclosure ML23313A0962023-11-13013 November 2023 Integrated Inspection Report 05000313/2023003 and 05000368/2023003 and Independent Spent Fuel Storage Installation Inspection Report 07200013/2023001 ML23311A2082023-11-0909 November 2023 Reassignment of U.S. Nuclear Regulatory Commission Branch Chief in the Division of Operating Reactor Licensing for Plant Licensing Branch IV IR 05000313/20230112023-10-10010 October 2023 Commercial Grade Dedication Inspection Report 05000313/2023011 and 05000368/2023011 IR 05000313/20230052023-08-21021 August 2023 Updated Inspection Plan for Arkansas Nuclear One, Units 1 and 2 (Report 05000313/2023005 and 05000368/2023005) - Mid Cycle IR 05000313/20243012023-08-14014 August 2023 Notification of NRC Initial Operator Licensing Examination 05000313/2024301 IR 05000313/20230022023-08-11011 August 2023 Integrated Inspection Report 05000313/2023002 and 05000368/2023002 and Notice of Violation ML23209A6022023-08-0909 August 2023 Regulatory Audit Plan in Support of License Amendment Request to Revise Technical Specifications to Adopt Risk- Informed Completion Times IR 05000416/20230022023-08-0808 August 2023 Integrated Inspection Report 05000416/2023002 and Independent Spent Fuel Storage Installation Inspection Report 07200050/2023001 ML23208A2132023-08-0303 August 2023 Regulatory Audit Summary Concerning Review of License Amendment Request to Remove Technical Specification Condition Allowing Two Reactor Coolant Pump Operation ML23208A2112023-07-27027 July 2023 Entergy Operations Inc., Application to Revise Technical Specifications to Adopt TSTF-205, Revision of Channel Calibration, Channel Functional Test, and Related Definitions ML23188A1732023-07-12012 July 2023 Request for Withholding Information from Public Disclosure ML23142A2022023-06-29029 June 2023 Issuance of Amendment Nos. 279 and 332 Emergency Plan Staffing Requirements IR 05000313/20234032023-06-28028 June 2023 Security Baseline Inspection Report 05000313/2023403 and 05000368/2023403 ML23178A0892023-06-26026 June 2023 August 2023 Emergency Preparedness Program Inspection-Request for Information ML23166B0902023-06-21021 June 2023 Request for Relief ANO1 ISI 036 Regarding Volumetric Examination Requirements ML23180A1082023-06-20020 June 2023 ANO Unit 1 SAR Amendment 31, TRM, TS Bases, 10 CFR 50.59 Report, and Commitment Change Summary Report IR 05000313/20234012023-06-13013 June 2023 Cyber Security Inspection Report 05000313/2023401 and 05000368/2023401 ML23130A2972023-05-17017 May 2023 Notification of Inspection (NRC Inspection Report 05000313/2023003) and Request for Information ML23121A3012023-05-10010 May 2023 Regulatory Audit Plan in Support of License Amendment Request to Revise Technical Specifications to Adopt Risk - Informed Completion Times ML23114A3572023-05-10010 May 2023 Regulatory Audit Summary Concerning Review of Request for Alternative ANO-CISI-002 Regarding Containment Inservice Inspection Frequency ML23130A2732023-05-10010 May 2023 and Waterford 3 Steam Electric Station - Response to Regulatory Issue Summary 2023-01, Preparation and Scheduling of Operator Licensing Examinations IR 05000313/20230012023-05-0909 May 2023 Integrated Inspection Report 05000313/2023001 and 05000368/2023001 ML23118A3202023-05-0808 May 2023 Notification of Biennial Problem Identification and Resolution Inspection and Request for Information (05000313;05000368/2023010) IR 05000368/20233012023-05-0101 May 2023 NRC Examination Report 05000368/2023301 ML23117A2172023-05-0101 May 2023 Safety Evaluation for Quality Assurance Program Manual Reduction in Commitment ML23108A1362023-04-24024 April 2023 Approval of Request for Half-Nozzle Repair of Reactor Vessel Closure Head Penetration No. 46 ML23110A1122023-04-20020 April 2023 Annual Report for Entergy Quality Assurance Program Manual Changes Under 10 CFR 50.54(a)(3), 10 CFR 71.106, and 10 CFR 72.140(d). Notification of Application of Approved Appendix B to 10 CFR 72 Subpart G 2024-01-24
[Table view]Some use of "" in your query was not closed by a matching "". |
Text
August 3, 2023 ANO Site Vice President Arkansas Nuclear One Entergy Operations, Inc.
N-TSB-58 1448 S.R. 333 Russellville, AR 72802
SUBJECT:
ARKANSAS NUCLEAR ONE, UNIT 1 - REGULATORY AUDIT
SUMMARY
CONCERNING REVIEW OF LICENSE AMENDMENT REQUEST TO REMOVE TECHNICAL SPECIFICATION CONDITION ALLOWING TWO REACTOR COOLANT PUMP OPERATION (EPID L-2022-LLA-0161)
Dear Sir or Madam:
By letter dated October 31, 2022 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML22304A669), as supplemented by letter dated June 29, 2023, (ML23180A292), Entergy Operations, Inc. (the licensee) submitted a license amendment request (LAR) that would remove Condition A, One RCP [Reactor Coolant Pump] not in operation in each loop, of Technical Specification 3.4.4, RCS [Reactor Coolant System] Loops
- MODES 1 and 2, for Arkansas Nuclear One, Unit 1.
To support its review of the LAR, the U.S. Nuclear Regulatory Commission (NRC) staff conducted a regulatory audit via the use of an online reference portal set up by the licensee.
The NRC staff reviewed calculations and analyses supporting the licensees LAR. The audit summary is enclosed.
If you have any questions, please contact me at (301) 415-4037 or by email at Thomas.Wengert@nrc.gov.
Sincerely,
/RA/
Thomas J. Wengert, Senior Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-313
Enclosure:
Audit Summary cc: Listserv
REGULATORY AUDIT
SUMMARY
CONCERNING REVIEW OF LICENSE AMENDMENT REQUEST REGARDING PROPOSED REMOVAL OF CONDITION A OF TECHNICAL SPECIFICATION 3.3.4 ENTERGY OPERATIONS, INC.
ARKANSAS NUCLEAR ONE, UNIT 1 DOCKET NO. 50-313
1.0 BACKGROUND
By letter dated October 31, 2022 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML22304A669), as supplemented by letter dated June 29, 2023, (ML23180A292), Entergy Operations, Inc. (the licensee) submitted a license amendment request (LAR) that would remove Condition A, One RCP [Reactor Coolant Pump] not in operation in each loop, of Technical Specification (TS) 3.4.4, RCS [Reactor Coolant System]
Loops - MODES 1 and 2, for Arkansas Nuclear One, Unit 1 (ANO-1). In its application dated October 31, 2022, the licensee stated that the proposed change would make ANO-1 TS 3.4.4 consistent with NUREG-1430, Standard Technical Specifications - Babcock and Wilcox Plants, Revision 5, Volume 1, Specifications, dated September 2021 (ML21272A363).
The U.S. Nuclear Regulatory Commission (NRC) staff reviewed the licensees LAR and determined that a regulatory audit would assist in the timely completion of the licensing review process. The audit was conducted in accordance with the audit plan dated January 27, 2023 (ML23020A936).
2.0 AUDIT DATES AND LOCATION The regulatory audit was conducted via an internet portal established by the licensee from February 13, 2023, through August 2, 2023.
3.0 AUDIT ACTIVITIES The purpose of the audit was for the NRC staff to examine the licensees non-docketed information with the intent to gain a better understanding of the LAR, to verify information, and to identify information that may require docketing to support the basis of the NRC staffs licensing decision. The audit activities conducted by the NRC staff included a review of calculations, reports, and analyses supporting the licensees LAR.
The licensee provided the following supporting calculations and evaluations for the NRC staff to review via the online reference portal:
Calculation No. BAW-10103A-03, 24 Hour 2 RCP Limit 2nd Justification (extract),
Revision 3, (Proprietary)
Enclosure
Calculation No. BAW-10103A-03, Appendix A, Partial Loop-LOCA [Loss-of-Coolant Accident] Analysis, Revision 1, August 29, 1975 Calculation No. CALC-ANO1-NE-20-00001, Safety Analysis Ground Rules Flow Fraction Curves for Various Number of RCP Coastdowns, Revision 0, figure E-1, Flow Fraction for 4-Pump Coastdown, 2-Pump Operation, 1-Pump Coastdown and Locked Rotor Events (Proprietary)
Calculation No. CALC-22-E-0001-11EC 93070, ANO RPS [Reactor Protection System]
to Power Monitor Setpoint, Revision 0, August 10, 2022 B&W [Babcock and Wilcox] Document 32-1123487-0, ANO NI [Nuclear Instrumentation]/RPS String Error Calculations, March 16, 1981 (Proprietary)
AREVA Document BAW Document 10179P-A-009, Safety Criteria and Methodology for Acceptable Cycle Reload Analyses, Revision 9, November 2017 (Proprietary)
B&W Document 51-1153314-00, ANO-1 Setpoint Methodology Document, August 28, 1986 The NRC staff conducted an audit teleconference with the licensee on March 14, 2023. During the teleconference, the licensee responded to the NRC staffs questions, clarified various elements of the supporting calculations and evaluations, and explained how the calculations supported the LAR.
4.0 RESULTS OF THE AUDIT During the audit, the NRC staff did not make any regulatory decisions regarding the LAR under the NRC staffs review. At the conclusion of the audit, the NRC staff informed the licensee that it would be issuing a request for additional information following the completion of its review of the audit portal information. The licensee subsequently elected to provide the supplemental letter dated June 29, 2023, which contained the additional information for docketing identified by the NRC staff during the audit. The NRC staff noted that the audit facilitated the NRC staffs timely review of the request.
5.0 AUDIT PARTICIPANTS NRC Participants from the Office of Nuclear Reactor Regulation Santosh Bhatt, Division of Safety Systems, Nuclear Systems Performance Branch Calvin Cheung, Division of Engineering and External Hazards, Instrumentation and Controls Branch Thomas Wengert, Division of Operating Reactor Licensing, Plant Licensing Branch IV Licensee Participants Mark Reid, ANO Licensing Chris Walker, ANO Safety Analysis Bill Carter, Entergy Corporate Fuels, Core Design Matt Bindeman, ANO Safety Analysis
Howard Mahan, Entergy Corporate Licensing Eve Clevenger, Supervisor, Entergy Corporate Safety Analysis Bob Baxter, Framatome Matt Dushaw, Framatome Jason St. Clair, Framatome 6.0 EXIT BRIEFING On August 2, 2023, Thomas Wengert of the NRC informed Mark Reid of Entergy, via telephone, that the NRC staff did not need to review any additional calculations or evaluations and, accordingly, the audit was concluded.
ML23208A213 *by email NRR-106 OFFICE NRR/DORL/LPL4/PM* NRR/DORL/LPL4/LA* NRR/DSS/SNSB/BC*
NAME TWengert PBlechman PSahd DATE 7/27/2023 7/31/2023 8/2/2023 OFFICE NRR/DEX/EICB/BC* NRR/DORL/LPL4/BC* NRR/DORL/LPL4/PM*
NAME RStattel JDixon-Herrity TWengert DATE 8/3/2023 8/3/2023 8/3/2023