Site: Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant, Crane  
Issue date: 07/09/1993
From: Grimes B
Office of Nuclear Reactor Regulation
To:
References
IN-93-051, NUDOCS 9307010233
Download: ML031070374 (12)


r

-

UNITED STATES

NUCLEAR REGULATORY COMMISSION

OFFICE OF NUCLEAR REACTOR REGULATION

WASHINGTON, D.C. 20555

July 9, 1993

NRC INFORMATION NOTICE 93-51:

REPETITIVE OVERSPEED TRIPPING OF TURBINE-DRIVEN

AUXILIARY FEEDWATER PUMPS

Addressees

All holders of operating licenses or construction permits for nuclear power

reactors.

Purpose

The U.S. Nuclear Regulatory Commission (NRC) is issuing this information

notice to alert addressees to the problem of repetitive tripping of turbine- driven auxiliary feedwater pumps (TDAFWPs) at the South Texas Project Electric

Generating Station.

It is expected that recipients will review the

information for applicability to their facilities and consider actions, as

appropriate, to avoid similar problems. However, suggestions contained in

this information notice are not NRC requirements; therefore, no specific

action or written response is required.

Description of Circumstances

On December 27, 1992, Houston Lighting & Power Company (the licensee)

performed a monthly surveillance test on its Unit 1 TDAFWP. After receiving a

start signal, the pump immediately tripped on an overspeed condition. The

operators repeated the surveillance test after a successful local manual

start. On this attempt the pump successfully started, and the licensee

subsequently considered the pump operable.

On January 23, 1993, Unit 2 tripped from 100-percent power on low water level

in one of the steam generators. The trip occurred because electro-hydraulic

control oil to the steam generator main feedwater pump turbine was lost. The

Unit 2 TDAFWP started on demand and was later secured when no longer required.

After the pump was secured, problems occurred when operators attempted to

relatch MOV-514 (the TDAFWP trip/throttle valve) from the control room.

(See

Figure 1.)

The pump was declared inoperable. The licensee conducted a

significant amount of troubleshooting and testing on the TDAFWP to resolve the

MOV-514 relatch problem and another speed control problem that was identified

during the testing. After the operability surveillance test was completed

successfully, the TDAFWP was declared operable and the unit was restarted on

January 25, 1993.

On January 28, 1993, the Unit 1 TDAFWP was tested as part of a routine monthly

surveillance. When started, the TDAFWP immediately tripped on an overspeed

condition and was subsequently declared inoperable. From January 28 through

9307010233 P

9t

PC

w3

- oSI

915 I

-I

IN 93-51 July 9, 1993 January 30, 1993, the licensee undertook an extensive testing and

troubleshooting effort to determine the cause of the problem with the TDAFWP.

Numerous pump starts were completed.

Several problems (overspeed tripping, lack of speed control, oscillations, and inability to maintain rated full- load, steady-state speed) were identified. On January 30, 1993, the Unit 1 TDAFWP was declared operable following extensive maintenance activities and

the successful completion of the surveillance test.

On February 1, 1993, the Unit 1 TDAFWP was tested again at the direction of

the Unit 1 operations manager in order to ensure operability, considering the

numerous problems encountered previously. After receiving a start signal, the

pump tripped on an overspeed condition and was declared inoperable.

On February 3, 1993, Unit 2 was operating at 100-percent power.

Two steam- driven steam generator main feedwater pumps and one electric startup feedwater

pump were providing feed flow to the steam generators.

The startup feedwater

pump tripped when the pump lubricating oil duplex strainers were being

shifted. Operators began to manually ramp down power but were unable to avoid

the low steam generator level. The operators subsequently initiated a manual reactor trip before receiving an automatic reactor protection system trip

signal on low steam generator level. Following the plant trip, the Unit 2 TDAFWP received an automatic signal to supply water to the steam generators.

The pump started but immediately tripped on an overspeed condition.

On February 4, 1993, Unit 1 commenced a shutdown to place the reactor in the

mode required by the Technical Specifications because the TDAFWP had not been

restored to an operable condition within the outage time allowed by the

Technical Specifications.

Further details can be found in License Event Report 50-498/93-007 and NRC

Inspection Reports 50-498; 50-499/93-05 and 50-498; 50-499/93-07.

Discussion

Although the licensee did not identify the root cause of the Unit 1 TDAFWP

overspeed trips, the proximate cause was determined to be the intrusion of

water into the TDAFWP turbine that adversely affected its performance.

However, this cause was effectively masked for several surveillance tests

because the surveillance test program established to satisfy the operability

requirements of the Technical Specifications was not sufficiently rigorous to

assure that the testing was performed under suitable environmental conditions.

The TDAFWP was not returned to its normal standby condition before each of the

TDAFWP surveillance tests performed on December 27, 1992, and

January 30, 1993. Because of this, the pump was not tested in its normal

standby condition and degraded conditions affecting operability were not

revealed.

IN 93-51 July 9, 1993 The licensee determined that the root cause of the February 3, 1993, Unit 2 TDAFWP overspeed trip was an incorrect valve lineup in conjunction with an

Inoperable or degraded steam trap. The valves and the steam trap are located

in the drain line from the steam admission line.

(See Figure 1.)

The TDAFWP

overspeed trip was caused by excessive condensate buildup in the steam supply

line upstream of the trip/throttle valve (MOV-514 in Figure 1).

The excessive

condensate had accumulated because the steam trap bypass valve, MS-517, was

incorrectly positioned (closed) and the steam trap had degraded to such an

extent that it was no longer capable of passing condensate to the condenser.

The licensee took the following corrective actions related to the hardware

modifications for both units:

The trip/throttle valves and governors were sent to the respective

vendors for complete refurbishment and testing.

The gearing arrangement

of the trip/throttle valve was modified to ensure slower stroke time, thus enabling a more positive governor response.

The TDAFWP drain system was modified to remove the steam traps in the

steamline drain system, replacing them with a spool piece.

Also, the

trip/throttle valve high-pressure steam leakoff was separated from the

turbine casing drain line and rerouted to the sump to prevent possible

intrusion of steam into the turbine casing.

(See Figure 2.)

Related Generic Communications

NRC Information Notice 86-14, Supplement 2, "Overspeed Trips of AFW,

HPCI, and RCIC Turbines," dated August 26, 1991.

NRC Information Notice 88-09, "Reduced Reliability of Steam-Driven

Auxiliary Feedwater Pumps Caused by Instability of Woodward PG-PL Type

Governors," dated March 18, 1988.

IE Information Notice 86-14, Supplement 1, "Overspeed Trips of AFW, HPCI,

and RCIC Turbines," dated December 17, 1986.

IE Information Notice 86-14, "PWR Auxiliary Feedwater Pump Turbine

Control Problems," dated March 10, 1986.

.IN 93-51 July 9, 1993 This information notice requires no specific action or written response.

If

you have any questions about the information in this notice, please contact

one of the technical contacts listed below or the appropriate Office of

Nuclear Reactor Regulation (NRR) project manager.

Brian K. Grimes, Director

Division of Operating Reactor Support

Office of Nuclear Reactor Regulation

Technical contacts: Mark A. Satorius, RIV

(817) 860-8141

William D. Johnson, RIV

(817) 860-8148

Peter C. Wen, NRR

(301) 504-2832 Attachments:

1. Figure 1, Existing South Texas Project

TDAFWP Steam Supply and Exhaust System

2. Figure 2, Modified South Texas Project

TDAFWP Steam Supply and Exhaust System

3. List of Recently Issued NRC Information Notices

MOV-143

STEAM EXHAUST

LINE

STEAM ADMISSION

LINE

MOV-514 TERRY

TURBINE

(

STEAM ADMISSION

LINE DRAIN

VALVES

PIPE CAP WITH ORIFICE

If

(UNIT I ONLY)

MS

371 MS

370

FO 7537B

~1 I I

FO 7537A--Yl

MS TURBINE CASING

373 DRAIN VALVE

STEAM TRAP

BYPASS

VALVE

STEAM

TRAP

w

I1

°% I'-

(D% %D

n

0D

w

I-a%0

r

CONDENSER

FIGURE 1 TDAFWP STEAM SUPPLY AND EXHAUST SYSTEM (UNMODIFIED)

MOV-143

STEAM EXHAUST

LINE

STEAM ADMISSION

LINE

MOV-514 TERRY

TURBINE

C

STEAM ADMISSION

UNE DRAIN

VALVES

MS

370

FO 7537B

MS TURBINE CASING

373 DRAIN VALVE

MS

515 STEAM TRAP

BYPASS

VALVE

SPOOL

PIECE

m 'z

--

~

HAQ %D t

" MD3

%O D

" D

Wa

"

MS

516 CONDENSER

FIGURE 2 TDAFWP STEAM SUPPLY AND EXHAUST SYSTEM (MODIFED)

Attachment 3

IN 93-51

July 9, 1993 LIST OF RECENTLY ISSUED

NRC INFORMATION NOTICES

Information

Date of

Notice No.

Subject

Issuance

Issued to

93-50

93-49

93-48

92-06, Supp. 1

93-47

Extended Storage of

Sealed Sources

Improper Integration of

Software into Operating

Practices

Failure of Turbine-

Driven Main Feedwater

Pump to Trip Because of

Contaminated Oil

Reliability of ATWS

Mitigation Systems and

Other NRC-Required Equip- ment not Controlled by

Plant Technical Specifica- tion

Unrecognized Loss of

Control Room Annunciators

Potential Problem with

Westinghouse Rod Control

System and Inadvertent

Withdrawal of A Single

Rod Control Cluster Assembly

Degradation of Shutdown

Cooling System Performance

Operational Challenges

During A Dual-Unit

Transient

Use of Inappropriate

Lubrication Oils in

Safety-Related Applications

07/08/93

07/08/93

7/6/93

07/01/93

06/18/93

6/10/93

06/16/93

06/15/93

06/10/93

All licensees authorized

to possess sealed sources.

All holders of OLs or CPs

for nuclear power reactors.

All holders of OLs or CPs

for nuclear power reactors.

All holders of OLs or CPs

for nuclear power reactors.

All holders of OLs or CPs

for nuclear power reactors.

All holders of OLs or CPs

for Westinghouse (W)-

designed nuclear power

reactors.

All holders of OLs or CPs

for nuclear power reactors.

All holders of OLs or CPs

for nuclear power reactors.

All holders of OLs or CPs

for nuclear power reactors.

93-46

93-45

93-44

93-43 OL = Operating License

CP - Construction Permit

\\,-

IN 93-51 July 9, 1993 This information notice requires no specific action or written response.

If

you have any questions about the information in this notice, please contact

one of the technical contacts listed below or the appropriate Office of

Nuclear Reactor Regulation (NRR) project manager.

orig /s/'d by BKGrimes

Brian K. Grimes, Director

Division of Operating Reactor Support

Office of Nuclear Reactor Regulation

Technical contacts:

Mark A. Satorius, RIV

(817) 860-8141

William D. Johnson, RIV

(817) 860-8148

Peter C. Wen, NRR

(301) 504-2832 Attachments:

1. Figure 1, Existing South Texas Project TDAFWP

Steam Supply and Exhaust System

2. Figure 2, Modified South Texas Project

TDAFWP Steam Supply and Exhaust System

3. List of Recently Issued NRC Information Notices

  • SEE PREVIOUS CONCURRENCE

OFFICE

  • OGCB:DORS
  • DRP:RIV
  • SC:DRP:RIV
  • D:DRP:RIV

NAME

PCWen/vsb

l MASatorius

MFMejac

WDJohnson

ABBeach

DATE

06/01/93 l 06/02/93

06/02/93

06/04/93

06/04/93

  • PM:PDV:NRR
  • C:SPLB:DSSA:NRR
  • D:DSSA:NRR *C:OGCB:DORS:NRR

D

LEKokaJko

CEMcCracken

ACThadani

GHMarcus

dd____

06/08/93

06/09/93

06/10/93

06/16/93 DOCUMENT NAME:

93-51.IN

IN 93-xx

June xx, 1993 This information notice requires no specific action or written response.

If

you have any questions about the information in this notice, please contact

one of the technical contacts listed below or the appropriate Office of

Nuclear Reactor Regulation (NRR) project manager.

Brian K. Grimes, Director

Division of Operating Reactor Support

Office of Nuclear Reactor Regulation

Technical contacts:

Mark A. Satorius, RIV

(817) 860-8141

William D. Johnson, RIV

(817) 860-8148 Peter

(301)

C. Wen, NRR

504-2832 Attachments:

1. Figure 1, Existing South Texas Project TDAFWP Steam

System

2. Figure 2, Modified South Texas Project TDAFWP Steam

System

3. List of Recently Issued NRC Information Notices

Supply and Exhaust

Supply and Exhaust

  • SEE PREVIOUS CONCURRENCE

OFFICE

  • OGCB:DORS
  • DRP:RIV
  • SC:DRP:RIV
  • D:DRP:RIV

N.ME

PCWen/vsb

MASatorius

MFMejac

WDJohnson

ABBeach

DATE

06/01/93

06/02/93

06/02/93

06/04/93

06/04/93

  • PM:PDV:NRR l *C:SPLB:DSSA:NRR
  • D:DSSA:NRR

C:OGCB:DORS:NRR

D

LEKokaiko

CEMcCracken

l ACThadani

GHMarcus(

r

lines

06/08/93

1 06/09/93

06/10/93

06//6/93

06/,z/93 DOCUMENT NAME:

INTDAFWP.WP

6

IN 93-xx

June xx, 1993 This information notice requires no specific action or written response.

If

you have any questions about the information in this notice, please contact

one of the technical contacts listed below or the appropriate Office of

Nuclear Reactor Regulation (NRR) project manager.

Brian K. Grimes, Director

Division of Operating Reactor Support

Office of Nuclear Reactor Regulation

Technical contacts:

Mark A. Satorius, RIV

(817) 860-8141

William D. Johnson, RIV

(817) 860-8148

Peter C. Wen, NRR

(301) 504-2832 Attachments:

1. Figure 1, Existing South Texas Project TDAFWP Steam Supply and Exhaust

System

2. Figure 2, Modified South Texas Project TDAFWP Steam Supply and Exhaust

System

3.

List of Recently Issued NRC Information Notices

  • SEE PREVIOUS CONCURRENCE

OFFICE

  • OGCB:DORS
  • DRP:RIV
  • SC:DRP:RIV
  • D:DRP:RIV

NAME

PCWen/vsb

MASatorius

MFMejac

WDJohnson

ABBeach

DATE

06/01/93

06/02/93

06/02/93

06/04/93

06/04/93 PM PDV:NRR

P

e

E

BC:OGCB:DORS:NRR

D:DORS:NRR

LEKokaiko

CEMcCI

J

dThadani

GHMarcus

BKGrimes

06/1 /93

06/ "/93

06/f/L93

06/ /93

06/ /93 DOCUMENT NAME:

INTDAFWP.WP

l

06-S12-1119

14t130

.

.1

06/04/93

15:05

301

5

34

37 R I'J US NRC FTS 728-327'3

NRC WHZTEl LINT F

002 P.02 IN 93-xx

Junt Xx, 1993 rhis iofwmtion notice requires no specific act on or written response.

If

yew ton &

questions about the information in his notice, please contact

  • a of

tochnical contacts listed bolow or th

appropriate Office of

btlw lector Regulation (NRR) project manager

Toc"ial contatts:

Brian K. Gripes, Director

Division of OPerating Reactor Support

Office of Nuclear Reactor Regulation

MKrk A. Satorius, RI'

(817) 660-4141

William D. Johnton, RIV

(817) B6O-814B

Peter C. Win

NRR

(301) 504-28i2 fttocwtsz:1

1.

fig"

It Existing South Texas Project TDAfWP Steam Supply

9 t

1. FlKrp

2, Modified South Texas Project TDA4I P Steam Supply

S. stoe

.

ist tf Recently Issued NRC Information Noice~s

and Exhaust

and Exhaust

I

Q2I fIaCURR

E

_.__

I___

-(,

0 1 93 PCmn/sb

tSu:D~ohnn

-/0ul

__

06/02/931

0/P3 OS

.6

/

.

CttKn-ANtrRR

D OSZiARR

9C OCt!R!OOR$:tRR

De:nRS!NRR

-


-I

ACHhadani

Marcus

bKoritme

U-

a

0r

w : 1"TuAokIrP

IN 93-xx

June xx, 1993

Page 3 of

This information notice requires no specific action or written response. If

you have any questions about the information in this notice, please contact

one of the technical contacts listed below or the appropriate Office of

Nuclear Reactor Regulation (NRR) project manager.

Brian K. Grimes, Director

Division of Operating Reactor Support

Office of Nuclear Reactor Regulation

Technical contacts:

Mark A. Satorius, RIV

(817) 860-8141

William D. Johnson, RIV

(817) 860-8148

Peter C. Wen, NRR

(301) 504-2832 Attachment:

List of Recently Issued NRC Information Notices

_.

__I

OFFICE

OGCB:DORS

DRP:RIV

TECH ED.

SC:DRP:RIV

D:DRP:RIV

NAME

PCWen/vsb

MASatorius

A.

WDJohnson

ABBeach

DATE

.06/ I /93

_

06/

/93

06/-L193 f06/ /93 l 06/ /93

. .

..

BC:SPLB:DSSA:NRR

D:DSSA:NRR

BC:OGCB:DORS:NRR

D:DORS:NRR

CEMcCracken

ACThadani

GHMarcus

BKGrimes

06/ /93

06/

/93

06/

/93

06/ /93 UMUWMMI

NAMt:

IN IUDAWFW.

WF