Reporting Requirements 5.6 5.6 Reporting Requirements

41.

The power distribution monitoring system referenced in various specifications and the BASES, is described in the following documents:

i.

CENPD-153-P, Latest Approved Revision, "Evaluation of Uncertainty in the Nuclear Power Peaking Measured by the Self-Powered, Fixed Incore Detector System" ii.

CEN-119(B)-P, "BASSS, Use of the Incore Detector System to Monitor the DNB-LCO on Calvert Cliffs Unit 1 and Unit 2," November 1979 iii. Letter from Mr. G. C. Creel (BG&E) to NRC Document Control Desk, dated February 7, 1989, "Calvert Cliffs Nuclear Power Plant Unit No. 2; Docket 50-318, Request for Amendment, Unit 2 Ninth Cycle License Application" iv.

Letter from Mr. S. A. McNeil, Jr. (NRC) to Mr. G. C. Creel (BG&E),

dated January 10, 1990, "Safety Evaluation Report Approving Unit 2 Cycle 9 License Application"

42.

Letter from Mr. D. G. McDonald, Jr. (NRC) to Mr. R. E. Denton (BGE),

dated May 11, 1995, "Approval to Use Convolution Technique in Main Steam Line Break Analysis - Calvert Cliffs Nuclear Power Plant, Unit Nos.

1 and 2 (TAC Nos.

M90897 and M90898)

43.

CENPD-387-P-A, Latest Approved Revision, "ABB Critical Heat Flux Correlations for PWR Fuel"

44.

CENPD-199-P, Supplement 2-P-A, Appendix A, Latest Approved Revision, "CE Setpoint Methodology," June 1998

45.

CENPD-404-P-A, Latest Approved Revision, "Implementation of ZIRLOTM Cladding Material in CE Nuclear Power Fuel Assembly Designs" CALVERT CLIFFS - UNIT 1 5.0-39 Amendment No.

251 CALVERT CLIFFS - UNIT 2 Amendment No.

228

Reporting Requirements 5.6 5.6 Reporting Requirements

46.

CENPD-132, Supplement 4-P-A, "Calculative Methods for the Break LOCA Evaluation Model"

47.

CENPD-137, Supplement 2-P-A, "Calculative Methods for the Evaluation Model" Latest Approved Revision, CE Nuclear Power Large Latest Approved Revision, ABB CE Small Break LOCA

c.

The core operating limits shall be determined such that all applicable limits (e.g., fuel thermal mechanical limits, core thermal hydraulic limits, ECCS limits, nuclear limits such as SDM, transient analysis limits, and accident analysis limits) of the safety analysis are met.

d.

The COLR, including any mid cycle revisions or supplements, shall be provided upon issuance for each reload cycle to the NRC.

Pressurizer Power-Operated Relief Valve and Safety Valve Report A report shall be submitted prior to March 1 of each year documenting all failures of and challenges to the pressurizer power-operated relief valves, or safety valves.

Post-Accident Monitoring Report When a report is required by Condition B or G of LCO 3.3.10, "Post Accident Monitoring Instrumentation," a report shall be submitted within the following 14 days.

The report shall outline the preplanned alternate method of monitoring, the cause of the inoperability, and the plans and schedule for restoring the instrumentation channels of the Function to OPERABLE status.

Tendon Surveillance Report Any abnormal degradation of the containment structure detected during the tests required by the Pre-Stressed Concrete Containment CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 5.0-40 Amendment No. 251 Amendment No. 228 5.6.6 5.6.7 5.6.8

Reporting Requirements 5.6 5.6 Reporting Requirements Tendon Surveillance Program shall be reported to the NRC within 30 days.

The report shall include a description of the tendon condition, the condition of the concrete (especially at tendon anchorages), the inspection procedures, the tolerances on cracking, and the corrective action taken.

5.6.9 Steam Generator Tube Inspection Report

a.

Following each inservice inspection of steam generator tubes, the number of tubes plugged or repaired in each steam generator shall be reported to the NRC within 15 days.

b.

The complete results of the steam generator tube inservice inspection during the report period shall be submitted to the NRC prior to March 1 of each year.

This report shall include:

1.

Number and extent of tubes inspected;

2.

Location and percent of wall-thickness penetration for each indication of an imperfection; and

3.

Identification of tubes plugged or repaired.

c.

Results of steam generator tube inspections which fall into Category C-3 require verbal notification of the NRC Regional Administrator by telephone within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to resumption of plant operation.

The written follow-up of this report shall provide a description of investigations conducted to determine cause of the tube degradation and corrective measures taken to prevent recurrence and shall be submitted within the next 30 days.

CALVERT CLIFFS - UNIT 1 5.0-41 Amendment No. 251 CALVERT CLIFFS - UNIT 2 Amendment No. 228