License Amendment Request: Change Regarding Mode Using the Consolidated Line Item Improvement Process
ML050330097
Person / Time
Site: Calvert Cliffs  
Issue date: 01/27/2005
From: Vanderheyden G
Constellation Energy Group
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML050330097 (32)


Text

George Vanderheyden Vice President Calvert Cliffs Nuclear Power Plant Constellation Generation Group, LLC 1650 Calvert Cliffs Parkway Lusby, Maryland 20657 410.495.4455 410.495.3500 Fax

@I Constellation Energy January 27, 2005-U. S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION:

Document Control Desk

SUBJECT:

Calvert Cliffs Nuclear Power Plant Unit Nos. I & 2; Docket Nos. 50-317 & 50-318 License Amendment Request:

Change Regarding Mode Using the Consolidated Line Item Imnrovement Process Change Limitations Pursuant to 10 CFR 50.90, Calvert Cliffs Nuclear Power Plant, Inc. requests an amendment to Renewed Operating License Nos. DPR-53 and DPR-69.

The proposed amendment would modify Technical Specification requirements for mode change limitations in Limiting Condition for Operation 3.0.4 and Surveillance Requirement 3.0.4.

Attachment (1) provides a description of the proposed change including a table of affected Technical Specifications with a brief description of the change, the requested confirmation of applicability, and plant-specific verifications. Attachment (2) provides the existing Technical Specification pages marked up to show the proposed change.

We request approval of the proposed change as soon as possible and not later than February 1, 2006. No outage process is dependent on approval. We request an implementation period of 60 days.

Document Control Desk January 27, 2005 Page 2 Should you have questions regarding this matter, we will be pleased to discuss them with you.

Very STATE OF MARYLAND

TO WIT:

COUNTY OF CALVERT 1, George Vanderheyden, being duly sworn, state that I am Vice President - Calvert Cliffs Nuclear Power Plant, Inc. (CCNPP), and that I am duly authorized to execute and file this License Amendment Request on behalf of CCNPP. To the best of my knowledge and belief, the statements contained in this document are true and correct. To the extent that these statements are not based on my personal knowledge, they are based upon information provided by other CCNPP employees and/or consultants. Such information has been reviewed in accordance with company practice and I believe it to. e reliable.

Subscribed and sworn before me, a Notary Public in and for the State of Maryland and County of (Iy'*Aft

, this 017a day of 2005.

WITNESS my Hand (V44Aw a. 6zzhX7J Notary Public Date GV/EMT/bjd Attachments:

(1) Description and Assessment (2) Proposed Technical Specification Changes cc:

S. L. Miller, Esquire J. E. Silberg, Esquire R. V. Guzman, NRC S. J. Collins, NRC Resident Inspector, NRC R. 1. McLean, DNR

ATTACHMENT (1)

DESCRIPTION AND ASSESSMENT TABLE OF CONTENTS

1.0 INTRODUCTION

2.0 PROPOSED CHANGE

3.0 TECHNICAL ANALYSIS

4.0 REGULATORY ANALYSIS

5.0 NO SIGNIFICANT HAZARDS CONSIDERATION

6.0 ENVIRONMENTAL CONSIDERATION

7.0 REGULATORY COMMITMENT

8.0 REFERENCES

Calvert Cliffs Nuclear Power Plant, Inc.

January 27, 2005

t ATTACHMENT (1)

DESCRIPTION AND ASSESSMENT

1.0 INTRODUCTION

The proposed amendment would modify Technical Specification requirements for mode change limitations in Limiting Condition for Operation (LCO) 3.0.4 and Surveillance Requirement (SR) 3.0.4.

The changes are consistent with Nuclear Regulatory Commission (NRC) approved Technical Specification Task Force (TSTF) Standard Technical Specification change TSTF-359-A, Revision 9 (Reference 1), which includes modifications noticed in the Federal Register published on April 4, 2003 (Reference 2). That Federal Register notice announced the availability of this Technical Specification improvement through the Consolidated Line Item Improvement Process (CLIIP).

This proposed change will allow mode changes while in an Action Condition if one of the following applies:

1. LCO 3.0.4.a - the Action has an unlimited Completion Time,
2. LCO 3.0.4.b - a risk analysis is performed, or
3. LCO 3.0.4.c - an Action containing a parameter has a note specifically allowing use of LCO 3.0.4.c.

2.0 PROPOSED CHANGE

CCNPP TSTF 359-A

SUMMARY

OF CHANGE CHANGE CHANGE Example 1.4-1 None Add reference to SR 3.0.4 LCO 3.0.4 LCO 3.0.4 Rewrite LCO to create three conditions SR 3.0.4 SR 3.0.4 Rewrite SR to defer to LCO 3.0.4 when a SR is not met 3.3.1.B 3.3.1.B Remove note 3.3.1.E 3.3.1.E Remove note 3.3.2.B 3.3.2.B Remove note 3.3.2.D 3.3.2.D Remove note 3.3.4.B 3.3.4.C Remove note 3.3.4.D 3.3.4.E Remove note 3.3.6.B 3.3.6.B Remove note 3.3.9.C 3.3.9.C Remove note 3.3.10 3.3.11 Remove note 3.3.11 3.3.12 Remove note 3.4.11 3.4.11 Remove note 3.4.12 3.4.12 Change note to say LCO 3.0.4.b is not applicable to PORVs when entering Mode 3 3.4.14 3.4.15 Remove note 3.4.15.A 3.4.16.A Remove note and insert note that 3.0.4.c is applicable 3.5.3 3.5.3 Insert note to say LCO 3.0.4.b is not applicable to ECCS HPSI subsystem when entering Mode 4 3.7.3 3.7.5 Insert note to say LCO 3.0.4.b is not applicable 3.7.3.A None Remove note 3.7.3.B None Remove note l

ATTACHMEENT (1)

DESCRIPTION AND ASSESSMENT CCNPP TSTF 359-A

SUMMARY

OF CHANGE CHANGE CHANGE 3.8.1 3.8.1 Insert note to say that LCO 3.0.4.b is not applicable to diesel generators unless otherwise noted 3.8.1.B None Insert note to say LCO 3.0.4.b is applicable in MODES 1,2, and 3 3.8.1.E None Insert note to say LCO 3.0.4.b is applicable in MODES 1,2, and 3

3.0 TECHNICAL ANALYSIS

Applicabilitv of Published Safety Evaluation We have reviewed the NRC's Safety Evaluation dated April 4, 2003 as part of the CLIIP. This review included a review of the NRC staffs evaluation, as well as the information provided to support TSTF-359-A Revision 9. We have concluded that the justifications presented in the TSTF proposal and the Safety Evaluation prepared by the NRC staff are applicable to Calvert Cliffs Units I and 2, and justify this amendment for the incorporation of the changes to the Calvert Cliffs' Technical Specifications.

Except as identified below, the changes requested are identical to those in the TSTF-359-A, Revision 9 markup.

Optional Changes and Variations We are proposing the following variations or deviations from the Technical Specification changes described in TSTF-359-A, Revision 9 and the NRC staffs model Safety Evaluation dated April 4, 2003.

1. A change is proposed to an example provided in Section 1.4 "Frequency."

Example 1.4-1 discusses what constitutes a violation of SR 3.0.4.

This example should be clarified to acknowledge the existence of the two exceptions contained within the proposed SR 3.0.4.

2. A change is proposed to LCO 3.0.4.c to change "allowance" to "note." This change clarifies the wording as allowance can be confused with a numerical range.
3. In the added note to LCO 3.4.12, the Mode being entered is proposed to be Mode 3 vice the Mode 4 stated in TSTF-359-A, Revision 9. When the Calvert Cliffs Technical Specifications were converted to the Improved Standard Technical Specifications (ISTS), LCO 3.4.12 Applicability was established as Mode 3 with an RCS cold leg < 3650F (Unit 1) and < 301OF (Unit 2).

Therefore, this new note is consistent with the current Calvert Cliffs Technical Specifications.

4. Calvert Cliffs has a note, that LCO 3.0.4 does not apply to Condition 3.7.3.A, that is not in the ISTS. We propose that note be removed. The global note that LCO 3.0.4.b does not apply is being added to LCO 3.7.3, as proposed in TSTF-359-A.
5. Calvert Cliffs has a note, that LCO 3.0.4 does not apply to Condition 3.7.3.B, that is not in the ISTS. We propose that note be removed. The global note that LCO 3.0.4.b does not apply is being added to LCO 3.7.3, as proposed in TSTF-359-A.
6. We request the addition of a note in LCO 3.8.1 prohibiting use of LCO 3.0.4.b for diesel generators except where otherwise noted. We are proposing the addition of notes to Required Actions 3.8.1.B and 3.8.1.E to allow use of LCO 3.0.4.b in Modes, 1, 2 and 3. Our diesel generator configuration allows more flexibility than considered in the owner's group risk evaluation (Reference 3).

2

ATITACHMENT (1)

DESCRIPTION AND ASSESSMENT Reference (3) states that the risk discussions related to diesel generators "are based on situations where TS DGs are the only source of emergency AC."

Calvert Cliffs has two sources of emergency power, an independent off-site transmission network and emergency diesel generators.

These sources are required in Technical Specification 3.8.1.

In addition, Reference (3) states that, besides those plants with alternate AC sources, plants with emergency AC cross-ties "may have sufficient redundancy such that additional flexibility in relaxing mode restraints can be justified." Calvert Cliffs has a total of five diesel generators for two units. Four diesel generators are automatically aligned to safety-related busses. The fifth diesel functions as an alternate AC power source as it can be manually aligned to any safety-related bus on either unit.

The diesel generators are considered of high safety significance within Reference (3) because they support portions of the auxiliary feedwater (AFW) systems and safety injection systems. Of these two systems, the AFW system has the highest importance at Calvert Cliffs. The impact of the loss of the diesel generators on these systems is reduced at Calvert Cliffs primarily due to:

  • The common electrical systems at the 125 VDC level. With only one of the five diesel generators available, two of the four safety-related 125 VDC buses will be available. These buses can power one channel of control instrumentation and two channels of indication instrumentation for both units.
  • The diversity of the diesel generators. Our diesel generators are of two significantly different designs.

This reduces the likelihood that all diesel generators will be lost due to some common mode failure.

  • The AFW configuration. Each unit has an AFW motor-driven pump that can be aligned to either unit (e.g., AFW pump 13 can support either Unit 1 or Unit 2).

Either of the two main buses can provide power to all safety-related buses. It would take multiple concurrent failures to cause the loss of both of the main buses in the switchyard.

  • The Southern Maryland Electric Cooperative 13 kV line. Independent of our switchyard is a separate offsite power supply that can be used to power one safety-related bus on each unit.
  • Minimizing switching of offsite power. We do not require transformer switching as the plant starts up.

We believe that our additional capacity beyond what is considered in Reference (3) allows additional flexibility in relaxing mode restraints for diesel generators. Therefore, the note added to Technical Specification 3.8.1 by TSTF-359-A, Revision 9 is modified in this proposal.

4.0 REGULATORY ANALYSIS

A description of this proposed change and its relationship to the applicable regulatory requirements and guidance was provided in the NRC Notice of Availability published on April 4, 2003 and TSTF-359-A, Revision 9.

Technical Specification Bases As discussed in the Notice of Availability published in the Federal Register on April 4, 2003 for this improvement, the Technical Specification Bases will be changed on approval of this proposed amendment 3

ATTACHMENT (1)

DESCRIPTION AND ASSESSMENT to conform with TSTF-359-A, Revision 9. The Bases will be modified to accommodate the deviations described in this letter.

Calvert Cliffs' Technical Specifications contain requirements for a Technical Specification Bases Control Program, consistent with the Bases Control Program described in Section 5.5 of the Combustion Engineering ISTS. The ISTS requirements of SR 3.0.1 and associated Bases are also contained in the Calvert Cliffs' Technical Specifications.

5.0 NO SIGNIFICANT HAZARDS CONSIDERATION DETERMINATION We have reviewed the proposed No Significant Hazards Consideration determination published in the Federal Register as part of the CLIIP. We have concluded that the proposed No Significant Hazards Consideration determination presented in the Federal Register Notice is applicable to Calvert Cliffs and is hereby incorporated by reference to satisfy the requirements of 10 CFR 50.91 (a).

6.0 ENVIRONMENTAL CONSIDERATION

Calvert Cliffs has reviewed the Environmental Evaluation included in the model Safety Evaluation dated April 4, 2003 as part of the CLIIP.

We have concluded that the staffs findings presented in that evaluation are applicable to Calvert Cliffs and the evaluation is hereby incorporated by reference for this application.

7.0 REGULATORY COMMITMENT Calvert Cliffs will update the Technical Specification Bases as described above when this proposed license amendment is approved.

8.0 REFERENCES

1. TSTF-359-A, Revision 9, "Increase Flexibility in MODE Restraints"
2.

Federal Register Notice published April 4, 2003 (69 FR 16579): "Notice of Availability of Model Application Concerning Technical Specification Improvement to Modify Requirements Regarding Mode Change Limitations Using the Consolidated Line Item Improvement Process"

3.

Combustion Engineering Owners Group, CE NPSD-1207, Revision 0, "Qualitative Risk Assessment for Relaxation of Mode Entry Restraints," January 2001 4

ATTACHMENT (2)

PROPOSED TECHNICAL SPECIFICATION CHANGES Calvert Cliffs Nuclear Power Plant, Inc.

January 27,2005

INSERT 1 When an LCO is not met, entry into a MODE or other specified condition in the Applicability shall only be made:

a. When the associated ACTIONS to be entered permit continued operation in the MODE or other specified condition in the Applicability for an unlimited period of time, or
b. After performance of a risk assessment addressing inoperable systems and components, consideration of the results, determination of the acceptability of entering the MODE or other specified condition in the Applicability, and establishment of risk management actions, if appropriate; exceptions to this Specification are stated in the individual Specifications, or
c. When a note is inserted in the individual value, parameter, or other Specification, that allows application of this part.

This Specification shall not prevent changes in MODEs or other specified conditions in the Applicability that are required to comply with ACTIONS or that are part of a shutdown of the unit.

INSERT 2 Entry into a MODE or other specified condition in the Applicability of an LCO shall only be made when the LCO's Surveillances have been met within their specified Frequency, except as provided by SR 3.0.3.

When an LCO is not met due to Surveillances not having been met, entry into a MODE or other specified condition in the Applicability shall only be made in accordance with LCO 3.0.4.

This provision shall not prevent entry into MODES or other specified conditions in the Applicability that are required to comply with ACTIONS or that are part of the shutdown of the unit.

Frequency 1.4 1.4 Frequency EXAMPLE 1.4-1 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY Perform CHANNEL CHECK.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Example 1.4-1 contains the type of SR most often encountered in the Technical Specifications (TS). The Frequency specifies an interval (12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />) during which the associated Surveillance must be performed at least one time.

Performance of the Surveillance initiates the subsequent interval. Although the Frequency is stated as 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, an extension of the time interval to 1.25 times the stated Frequency is allowed by SR 3.0.2 for operational flexibility. The measurement of this interval continues at all times, even when the SR is not required to be met per SR 3.0.1 (such as when the equipment is inoperable, a variable is outside specified limits, or the unit is outside the Applicability of the LCO). If the interval specified by SR 3.0.2 is exceeded while the unit is in a MODE or other specified condition in the Applicability of the LCO, and the performance of the Surveillance is not otherwise modified (refer to Example 1.4-3), then SR 3.0.3 becomes applicable.

If the interval as specified by SR 3.0.2 is exceeded while the unit is not in a MODE or other specified condition in the Applicability of the LCO for which performance of the SR is required, the Surveillance must be performed within the Frequency requirements of SR 3.0.2 prior to entry into the MODE or other specified condition CALVERT CLIFFS - UNIT 1.

1.4-2 Amendment No. 227 CALVERT CLIFFS - UNIT 2 Amendment No. 201

LCO Applicability 3.0 3.0 LIMITING CONDITION FOR OPERATION (LCO) APPLICABILITY LCO 3.0.4 When an LCO is not met, entry into a MODE or ot er specified

>condition in the Applicability shall nJrfd except when

\\

(

the associated ACTIONS to be en ermit continued operation in the MODE orghfpecified condition in the/

4 Applicability for an mted period of time. This Specification not prevent changes in MODES or other specifiedfi^iiin in the Applicability that are required

/

\\ to y ith ACIONS or that are part of a shut down of Exceptions to this Specification are sta *d-In the individual Specifications.

LCO 3.0.4 is on able for entry into a MODE or other (specified tion in the Applicability in MODES 1, 2, 3, LCO 3.0.5 Equipment removed from service or declared inoperable to comply with ACTIONS may be returned to service under administrative control solely to perform testing required to demonstrate its OPERABILITY or the OPERABILITY of other equipment. This is an exception to LCO 3.0.2 for the system returned to service under administrative control to perform the testing required to demonstrate OPERABILITY.

LCO 3.0.6 CALVERT CLIFFS -

CALVERT CLIFFS -

When a supported system LCO is not met solely due to a support system LCO not being met, the Conditions and Required Actions associated with this supported system are not required to be entered.

Only the support system LCO ACTIONS are required to be entered. This is an exception to LCO 3.0.2 for the supported system. In this event, additional evaluations and limitations may be required in accordance with Specification 5.5.15, "Safety Function Determination Program (SFDP)." If a loss of safety function is determined to exist by this program, the appropriate Conditions and Required Actions of the LCO in which the loss of safety function exists are required to be entered.

UNIT 1 UNIT 2 3.0-2 Amendment No. 227 Amendment No. 201

SR Applicability 3.0 3.0 SURVEILLANCE REQUIREMENT (SR) APPLICABILITY If the Surveillance is not performed within the delay period, the LCO must immediately be declared not met, and the applicable Condition(s) must be entered.

When the Surveillance is performed within the delay period and the Surveillance is not met, the LCO must immediately be declared not met, and the applicable Condition(s) must be entered.

SR 3.0.4 Entry into a MODE or other specified condition the Applicability of an LCO shall not be m ess the LCO's Surveillances have been met wi their specified Frequency. This prov hall not prevent entry into

~

MODES or othe cified conditions in the Applicability thaurdt comply with ACTIONS, or that are part

\\

15~a sut dwn of the unit.

t speciied conition i h

-fp cRif~~-ity in MODES 1, 2, 3, CALVERT CLIFFS -

UNIT 1 CALVERT CLIFFS - UNIT 2 3.0-5 Amendment No. 227 Amendment No. 201

RPS Instrumentation-Operating 3.3.1 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME B. One or more Functions NOTE

with two RPS bistable CO 3.0.

le.

trip units or associated measurement channels 8.1 Place one affected 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> inoperable except for bistable trip unit in Condition C (excore bypass and place the channel not other affected calibrated with bistable trip unit in incore detectors).

trip.

AND B.2 Restore one affected 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> bistable trip unit and associated measurement channel to OPERABLE status.

C. One or more Functions C.1 Perform SR 3.3.1.3.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> with one or more power range excore OR channels not calibrated with the C.2 Restrict THERMAL 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> incore detectors.

POWER to < 90% RTP.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.3.1-2 Amendment No. 227 Amendment No. 201

RPS Instrumentation-Operating 3.3.1 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME E. One or more Functions


_ NOTE ----

with two automatic licable.

bypass removal C

feature channels inoperable.

E.1 Disable bypass 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> channels.

OR E.2.1 Place one affected 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> bistable trip unit in bypass and place the other in trip for each affected trip Function.

AND E.2.2 Restore one automatic 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> bypass removal feature and the affected bistable trip unit to OPERABLE status for each affected trip Function.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.3.1-4 Amendment No. 227 Amendment No. 201

RPS Instrumentation-Shutdown 3.3.2 ACTIONS (continued) j CONDITION REQUIRED ACTION COMPLETION TIME A. (Continued)

A.2.2 Place affected bistable trip unit in trip..

48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />..

1" t

B.

Two Rate of Change of Power-High bistable trip units or associated measurement channels inoperable.

r NOTE------

licable.

B. 1 Place one bistable trip unit in bypass and place the other bistable trip unit in trip.

1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> AND B.2 Restore one bistable trip unit to OPERABLE status.

48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />

,.i C. One automatic bypass removal feature inoperable.

C. 1 Disable bypass channel.

1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> 1 hour OR C.2.1 Place affected bistable trip unit in bypass or trip.

AND

)

CALVERT CLIFFS -

UNIT 1 CALVERT CLIFFS -

UNIT 2 3.3.2-2 Amendment No. 227 Amendment No. 201

RPS Instrumentation-Shutdown 3.3.2 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME C. (Continued)

C.2.2.1 Restore automatic 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> bypass removal feature and affected bistable trip unit to OPERABLE status.

OR 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> C.2.2.2 Place affected bistable trip unit in trip.

D. Two automatic bypass NOTE removal features LCO 3.0.4 i ble.

inoperable.

c '

D.1 Disable bypass 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> channels.

OR D.2.1 Place one affected 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> bistable trip unit in bypass and place the other in trip.

AND D.2.2 Restore one automatic 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> bypass removal feature and the affected bistable trip unit to OPERABLE status.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.3.2-3 Amendment No. 227 Amendment No. 201

ESFAS Instrumentation 3.3.4 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME B. One or more Functions-NOTE with two ESFAS sensor LCO 3.0.4 i cable.

modules or associated measurement channels inoperable.

B.1 Place one sensor 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> module in bypass and place the other sensor module in trip.

AND B.2 Restore one sensor 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> module and associated measurement channel to OPERABLE status.

C. One or more Functions C.1 Disable affected 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> with the automatic sensor block module.

block removal feature of one sensor block OR module inoperable.

C.2 Place affected sensor 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> block module in bypass.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.3.4-2 Amendment No. 227 Amendment No. 201

ESFAS Instrumentation 3.3.4 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME D. One or more Functions -NOTE with the automatic LCO 3.0.4 ie.

block removal feature of two sensor block modules inoperable.

D.1 Disable affected 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> sensor block modules.

OR D.2.1 Place one affected 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> sensor block module in bypass and disable the other for each affected ESFAS Function.

AND D.2.2 Restore one automatic 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> block removal feature and the associated sensor block module to OPERABLE status for each affected ESFAS Function.

E. Required Action and E.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.

AND E.2 Be in MODE 4.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.3.4-3 Amendment No. 227 Amendment No. 201

DG-LOVS 3.3.6 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME B. One or more Functions B.1 Enter applicable 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> with two sensor Conditions and modules or associated Required Actions for measurement channels the associated DG per DG inoperable.

made inoperable by DG-LOVS instrumentation.

OR B.2.1 NOTE

)CO 3.004_sft

)

Place one sensor 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> module in bypass and the other sensor module in trip.

AND B.2.2 Restore one sensor 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> module and associated measurement channel to OPERABLE status.

C. One or more Functions C.1 Restore at least two 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> with more than two sensor modules and sensor modules or associated associated measurement channels measurement channels to OPERABLE status.

inoperable.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.3.6-2 Amendment No. 227 Amendment No. 201

CVCS Isolation Signal 3.3.9 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME C. Two CYCS isolation NOTE---

sensor modules or LCO 3.0.4 i g

a~

p pplicable.

associated measurement channels inoperable.

C.1 Place one sensor 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> module in bypass and place the other sensor module in trip.

AND C.2 Restore one sensor 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> module and associated measurement channel to OPERABLE status.

D. Required Action and D.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.

AND D.2 Be in MODE 5.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.3.9.1 Perform a CHANNEL CHECK of each sensor 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> channel.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.3.9-2 Amendment No. 227 Amendment No. 201

PAM Instrumentation 3.3.10 3.3 INSTRUMENTATION 3.3.10 Post-Accident Monitoring (PAM) Instrumentation LCO 3.3.10 The PAM Indication channels for each Function in Table 3.3.10-1 shall be OPERABLE.

APPLICABILITY:

MODES 1, 2, and 3.

ACTIONS NOTE Separate Condition entry is allowed for each Function.

_1 ---

CONDITION REQUIRED ACTION COMPLETION TIME A. One or more Functions A.1 Restore required 30 days with one required indication channel to indication channel OPERABLE status.

inoperable.

B.

Required Action and B.1 Initiate action in Immediately associated Completion accordance with Time of Condition A Specification 5.6.7.

not met.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.3.10-1 Amendment No. 227 Amendment No. 201

Remote Shutdown Instrumentation 3.3.11 3.3 INSTRUMENTATION 3.3.11 Remote Shutdown Instrumentation LCO 3.3.11 The Remote Shutdown Instrumentation Functions in Table 3.3.11-1 shall be OPERABLE.

APPLICABILITY:

MODES 1, 2, and 3.

ACTIONS


NOTE'------------------------------------

/1.

3.0.4 isqpt-pplicable.

Separate Condition entry is allowed for each function.

CONDITION REQUIRED ACTION COMPLETION TIME A. One or more required A.1 Restore required 30 days Functions inoperable.

Functions to OPERABLE status.

B. Required Action and B.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.

AND B.2 Be in MODE 4.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.3.11-1 Amendment No. 227 Amendment No. 201

Pressurizer PORVs 3.4.11 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.11 Pressurizer Power-Operated Relief Valves (PORVs)

LCO 3.4.11 APPLICABILITY:

Two PORVs and associated block valves shall be OPERABLE.

MODES 1 and 2, MODE 3 with all RCS cold leg temperatures > 3650F (Unit 1),

> 3010F (Unit 2).

ACTIONS


NOTE' -----------------------------------

Separate Condition entry is allowed for each PORV.

2. LO3 4i o p1~e CONDITION REQUIRED ACTION COMPLETION TIME A. One or two PORVs A.1 Close and maintain 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> inoperable and power to associated capable of being block valve.

manually cycled.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.4.11-1 Amendment No. 227 Amendment No. 201

LTOP System 3.4.12 Figure 3.4.12-1 when the SDC System is not in operation and PORV lift setting

  • 429 psia (Unit 1),*S 443 psia (Unit 2), when the SDC is in operation; and an RCS vent of 2 1.3 square inches established; or
3. An RCS vent of 2 2.6 square inches established.

APPLICABILITY:

MODE 3 with any RCS cold leg temperature

  • 3651F (Unit 1),
  • 301OF (Unit 2),

MODES 4, 5, and 6.


NOTE --------------- __-_-_____

This Specification is not applicable when the RCS is vented to 2 8 square inches.

ACTIONS T--

While the requirements of this Limiting Condition for 0perat

met, entry into a MODE, or e

condition in the Applicability is not Vs A

LCO.OL~

i OI

?~(2 40IOF/

UtQ CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.4.12-2 Amendment No. 227 Amendment No. 201

RCS Leakage Detection Instrumentation 3.4.14 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.14 RCS Leakage Detection Instrumentation LCO 3.4.14 The following RCS leakage detection instrumentation shall be OPERABLE:

a. One containment sump level alarm; and
b. One containment atmosphere radioactivity monitor (gaseous or particulate).

APPLICABILITY:

MODES 1, 2, 3, and 4.

ACTIONS NOTE-LCO 3 isnot applicable.

--=_--=

CONDITION REQUIRED ACTION COMPLETION TIME A. Required containment A.1 Perform SR 3.4.13.1.

Once per sump level alarm 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> inoperable.

AND A.2 Restore containment 30 days sump level alarm to OPERABLE status.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.4. 14-1 Amendment Amendment No. 227 No. 201

RCS Specific Activity 3.4.15 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.15 RCS Specific Activity LCO 3.4.15 APPLICABILITY:

The specific activity of the reactor coolant shall be within limits.

MODES 1 and 2, MODE 3 with RCS average temperature (Tayg)

> 5000F.

ACTIONS CONDITION I

REQUIRED ACTION I COMPLETION TIME A.

DOSE EQUIVALENT I-131

> 1.0 tiCi/gm.

NOTE ------ V

_===

A.1 Verify DOSE EQUIVALENT I-131 within the acceptable region of Figure 3.4.15-1.

r 0 3. -q. c 10, C 0.. I. cc. (e.-

I Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> 100 hours AND A.2 Restore DOSE EQUIVALENT 1-131 to within limit.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.4.15-1 Amendment No. 227 Amendment No. 201

ECCS - Shutdown 3.5.3 3.5 EMERGENCY CORE COOLING SYSTEM (ECCS) 3.5.3 ECCS - Shutdown LCO 3.5.3 One high pressure safety injection (HPSI) train shall be OPERABLE.

NOTE ----------------------------

When Reactor Coolant System cold leg temperatures are < 3850F (Unit 1), < 3251F (Unit 2) during heatup or cooldown and when

  • 3650F (Unit 1),
  • 301OF (Unit 2), during other conditions, the HPSI train is not required to be capable of automatically starting on an actuation signal.

APPLICAEHILITY:

MODE 3 with pressurizer pressure < 1750 psia, MODE4 oCoN DITIq ON not X

EcIs t CtOMPt-AL s Max CONDITION tE IO-T A.

Required HPSI train A.1 Restore required HPSI 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> inoperable.

train to OPERABLE status.

B. Required Action and B.1 Be in MODE 5.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> associated Completion Time not met.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.5.3-1 Amendment No. 227 Amendment No. 201

AFW System 3.7.3 3.7 PLANT SYSTEMS 3.7.3 Auxiliary Feedwater (AFW) System LCO 3.7.3 Two AFW trains shall be OPERABLE.


NOTE ----------------------------

AFW trains required for OPERABILITY may be taken out of service under administrative control for the performance of periodic testing.

APPLICABILITY:

MODES 1, 2, and 3.

a L-C c

3..'q.b * % Ad+

L P Is

ACTIONS, CONDITION E

REQUIRED ACTION COMPLETION TIME NOTE --

LCO 3.0.4 is no applc V

7 A. One steam-driven AFW pump inoperable.

A.1 Align remaining OPERABLE steam-driven pump to automatic initiating status.

72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> AND A.2 Restore pump to status.

steam-driven OPERABLE 7 days AND 10 days from discovery of failure to meet the Limiting Condition for Operation (LCO)

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.7.3-1 Amendment No. 227 Amendment No. 201

AFW System 3.7.3 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME B.1 Align standby steam-driven pump to automatic initiating status.

!p~jzabe.

B. One motor-driven AFW pump inoperable.

AND B.2 Restore motor-driven pump to OPERABLE status.

72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> 7 days AND 10 days from discovery of failure to meet the LCO C. Two AFW pumps inoperable.

C.I Align remaining OPERABLE pump to automatic initiating status.

AND 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> 1 hour 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> C.2 Verify the other unit's motor-driven AFW pump is OPERABLE.

AND C.3 Verify, by administrative means, the cross-tie valve to the opposite unit is OPERABLE.

AND CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.7.3-2 Amendment No. 227 Amendment No. 201

Iof-HVo4-

-O l ACO N5S O~torLJ " 3 R-L t)

C CD

.s/

ACIOS A0 f

AC Sources-Operating 3.8.1 CONDITION J

REQUIRED ACTION ICOMPLETION TIME A. One required LCO 3.8.1.a offsite circuit inoperable.

A.1 Perform SR 3.8.1.1 or SR 3.8.1.2 for required OPERABLE offsite circuits.

AND A.2 Declare required feature(s) with no offsite power available inoperable when its redundant required feature(s) is inoperable.

1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> AND Once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> thereafter 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> from discovery of no offsite power to one train concurrent with inoperability of redundant required feature(s) 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> AND 17 days from discovery of failure to meet LCO 3.8.1.a or LCO 3.8.1.b AND A.3 Restore required offsite circuit to OPERABLE status.

I CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.8.1-2 Amendment No. 265 Amendment No. 242

AC Sources-Operating 3.8.1 ACTIONS (continued)

CONDITION l

REQUIRED ACTION I COMPLETION TIME B. One LC inoper O 3.8.l.b DG able.

B.

1 Verify both DGs on the other unit OPERABLE and OC DG available.

1 1hn-.

.JU -l A

11t AND Jul H N TS.

L CO 3, 0. q.b l

%,. C p II O, C(

I

_ G_

I AND B.2 Perform SR 3.8.1.1 or SR 3.8.1.2 for the OPERABLE required offsite circuit(s).

AND Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> AND Once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> thereafter 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> from discovery of Condition B concurrent with inoperability of redundant required feature(s) 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> B.3 Declare required feature(s) supported by the inoperable DG inoperable when its redundant required feature(s) is inoperable.

I AND B.4.1 Determine OPERABLE DG(s) is not inoperable due to common cause failure.

OR I

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.8.1-3 Amendment No. 265 Amendment No. 242

AC Sources-Operating 3.8.1 ACTIONS (continued)

CONDITION I

REQUIRED ACTION ICOMPLETION TIME E. LCO 3.8.1.c DG

/

inoperable.

AcrTe-

'MO D1 5 1, X, Md.

NOTE------------

Enter applicable Conditions and Required Actions of LCO 3.8.9, 'Distribution Systems-Operating," when Condition E is entered with no AC power source to a train.

E.I Verify both LCO 3.8.1.b DGs OPERABLE, the other unit's DG OPERABLE and the OC DG available.

I hour AND Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> AND AND E.2 Perform SR 3.8.1.1 or SR 3.8.1.2 for the OPERABLE required offsite circuit(s).

AND E.3 Declare CREVS, CRETS, or Hz Analyzer supported by the inoperable DG inoperable when the redundant CREVS, CRETS, or H2 Analyzer is inoperable.

Once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> thereafter 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> from discovery of Condition E concurrent with inoperability of redundant required feature(s)

AND CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.8.1-6 Amendment No. 265 Amendment No. 242