RPS Instrumentation-Operating 3.3.1 Table 3.3.1-1 (page 2 of 3)

Reactor Protective System Instrumentation SURVEILLANCE FUNCTION MODES REQUIREMENTS ALLOWABLE VALUE

6.

Steam Generator Pressure-Low(C)

7.

Steam Generator Level -Low

8.

Axial Power Distribution-Hi gh(d) 9a.

Thermal Margin/Low Pressure (TM/LP) (b) 1, 2 1, 2 1 (e)

SR SR SR SR SR SR SR SR SR SR SR SR SR SR SR SR SR SR SR SR SR SR SR SR SR 1, 2 3.3.1.1 3.3.1.4 3.3.1.7 3.3.1.8 3.3.1.9 3.3.1.1 3.3.1.4 3.3.1.8 3.3.1.9 3.3.1.1 3.3.1.2 3.3.1.3 3.3.1.4 3.3.1.5 3.3.1.7 3.3.1.8 3.3.1.9 3.3.1.1 3.3.1.2 3.3.1.3 3.3.1.4 3.3.1.5 3.3.1.7 3.3.1.8 3.3.1.9

> 685 psia

Ž 50 inches below normal water level*

In accordance with the COLR In accordance with the COLR For Unit 2, the ALLOWABLE VALUE feed ring through Cycle 14.

CALVERT CLIFFS - UNIT 1 3

CALVERT CLIFFS - UNIT 2 shall remain Ž 10 inches below top of

.3.1-10 Amendment No.

249 Amendment No.

225

RCS Pressure, Temperature, and Flow DNB Limits 3.4.1 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.1 RCS Pressure, Temperature, and Flow Departure from Nucleate Boiling (DNB)

Limits LCO 3.4.1 APPLICABILITY:

RCS DNB parameters for pressurizer pressure, cold leg temperature, and RCS total flow rate shall be within the limits specified below:

a.

Pressurizer pressure Ž 2200 psia;

b.

RCS cold leg temperature (Ta)

  • 548°F; and
c.

RCS total flow rate Ž 370,000* gpm.

MODE 1.


NOTE Pressurizer pressure limit does not apply during:

a.

THERMAL POWER ramp > 5% RTP per minute; or

b.

THERMAL POWER step > 10% RTP.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

RCS DNB parameter(s)

A.1 Restore parameter(s) 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> not within limits, to within limit.

For Unit 2, the RCS total flow rate shall remain Ž 340,000 gpm through Cycle 14.

CALVERT CLIFFS -

UNIT 1 CALVERT CLIFFS -

UNIT 2 3.4.1-1 Amendment No. 249 Amendment No.

225

RCS Pressure, Temperature, and Flow DNB Limits 3.4.1 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME B.

Required Action and B.1 Be in MODE 2.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.4.1.1 Verify pressurizer pressure Ž 2200 psia.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> SR 3.4.1.2 Verify RCS cold leg temperature

  • 548°F.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> SR 3.4.1.3 Verify RCS total flow rate Ž 370,000* gpm.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> SR 3.4.1.4 Verify measured RCS total flow rate is 24 months within limits.

For Unit 2, the RCS total flow rate shall Cycle 14.

CALVERT CLIFFS -

UNIT 1 CALVERT CLIFFS -

UNIT 2 3.4.1-2 remain Ž 340,000 gpm through Amendment No. 249 Amendment No. 225

Programs and Manuals 5.5 5.5 Programs and Manuals

5.

% Degradation means the percentage of the tube wall thickness affected or removed by degradation.

6.

Defect means an imperfection of such severity that it exceeds the plugging or repair limit.

A tube containing a defect is defective.

Any tube which does not permit the passage of the eddy-current inspection probe shall be deemed a defective tube.

7.

Plugging or Repair Limit means the imperfection depth at or beyond which the tube shall be removed from service by plugging, or repaired by sleeving in the affected area because it may become unserviceable prior to the next inspection.

The plugging or repair limit imperfection depths are specified in percentage of nominal wall thickness as follows:

i.

original tube wall 40%

ii.

ABB-Combustion Engineering leak tight sleeve wall (Unit 2 through Cycle 14 only.

Not applicable for Unit 1.)

28%

iii. ABB-Combustion Engineering Alloy 800 leak-limiting sleeve wall(Unit 2 through Cycle 14 only.

Not applicable for Unit 1.)

35%

8.

Unserviceable describes the condition of a tube if it leaks or contains a defect large enough to affect its structural integrity in the event of an Operating Basis Earthquake, a loss-of-coolant accident, or a steam line or feedwater line break as specified in 5.5.9.c.3 above.

9.

Tube Inspection means an inspection of the steam generator tube from the point of entry (hot leg side) completely around the U-bend to the top support of the cold leg.

CALVERT CLIFFS - UNIT 1 5.0-19 Amendment No. 249 CALVERT CLIFFS - UNIT 2 Amendment No.

225

Programs and Manuals 5.5 5.5 Programs and Manuals

10. Tube Repair refers to a process that reestablishes tube serviceability.

Acceptable tube repairs will be performed by the following processes:

i.

ABB-Combusting Engineering Leak Tight Sleeving as described in the proprietary ABB-Combustion Engineering Report CEN-630-P, Revision 01, "Repair of 3/4" O.D. Steam Generator Tubes Using Leak Tight Sleeves," August 1996.

A post-weld heat treatment during installation will be performed.

(Unit 2 through Cycle 14 only.

Not applicable for Unit 1.)

ii.

ABB-Combustion Engineering Alloy 800 leak-limiting sleeving as described in the Proprietary ABB Combustion Engineering Report CEN-633-P, Revision 03-P, "Steam Generator Tube Repair For Combustion Engineering Designed Plants with 3/4-.048 Inch Wall Inconel 600 Tubes Using Leak Limiting Alloy 800 Sleeves, " October 1998.

(Unit 2 through Cycle 14 only.

Not applicable for Unit 1.)

Tube repair includes the removal of plugs that were previously installed as a corrective or preventive measure.

A tube inspection per 5.5.9.d.9 is required prior to returning previously plugged tubes to service.

e.

Surveillance Completion - The Steam Generator Tube Surveillance Program is met after completing the corresponding actions (plug or repair all tubes exceeding the plugging limit and all tubes containing through-wall cracks) required by Tables 5.5.9-2 and 5.5.9-3.

CALVERT CLIFFS - UNIT 1 5.0-20 Amendment No. 249 CALVERT CLIFFS - UNIT 2 Amendment No. 225