ML082180496
Letter Sequence Other | |
---|---|
TAC:MD5509, (Open) | |
Initiation
Administration | |
MONTHYEARML0729701802007-11-15015 November 2007
[Table View]Calvert Cliff Nuclear Power Plant, Unit No. 1 - Request for Additional Information Long-Term Carborundum Coupon Surveillance Program Project stage: RAI ML0801403412008-01-10010 January 2008 Response to Request for Additional Information Regarding Long-Term Carborundum Coupon Surveillance Program Project stage: Response to RAI ML0820405792008-07-18018 July 2008 Additional Information for the Long-Term Carborundum Coupon Surveillance Program Project stage: Other ML0821804782008-08-27027 August 2008 Amendment No. 288 Long-Term Coupon Surveillance Program Project stage: Other ML0821804962008-08-27027 August 2008 Technical Specifications, Amendment No. 288 Project stage: Other 2008-01-10 |
ML082180496 | |
Person / Time | |
---|---|
Site: | Calvert Cliffs |
Issue date: | 08/27/2008 |
From: | Pickett D NRC/NRR/ADRO/DORL/LPLI-1 |
To: | Spina J Calvert Cliffs |
Pickett D | |
References | |
TAC MD5509 | |
Download: ML082180496 (1) | |
Similar Documents at Calvert Cliffs | |
---|---|
Category:Technical Specification
MONTHYEARML24103A2042024-04-12012 April 2024
[Table view]Constellation Energy Generation, LLC, Application to Revise Technical Specifications to Adopt TSTF-591-A, Revise Risk Informed Completion Time (RICT) Program Revision 0 and Revise 10 CFR 50.69 License Condition ML22298A0112022-10-25025 October 2022 License Amendment Request to Adopt Technical Specification Task Force TSTF-295-A, Modify Note 2 to Actions of (Post-Accident Monitoring) PAM Table To. RS-22-086, R. E. Ginna Nuclear Power Plant - Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam.2022-08-10010 August 2022 R. E. Ginna Nuclear Power Plant - Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam. RS-22-008, Application to Revise Technical Specifications 5.6.5, Core Operating Limits Report to Add References to NRC-Approved Topical Report with Admin2022-01-24024 January 2022 Application to Revise Technical Specifications 5.6.5, Core Operating Limits Report to Add References to NRC-Approved Topical Report with Admin ML21278A2972021-09-0707 September 2021 6 to Technical Specification Bases ML21165A4062021-06-14014 June 2021 Spent Fuel Pool Cooling - Shutdown Cooling Systems Licensing Design Basis License Amendment Request ML19346E5362019-12-11011 December 2019 License Amendment Request: 10 CFR 50.90 Proposed Changes to Technical Specification (TS) 3.8.1 Emergency Diesel Generator Surveillance Requirements for Frequency and Voltage Tolerances ML19325C1282019-11-21021 November 2019 License Amendment Request - Revision to Technical Specification 5.5.7, Reactor Coolant Pump Flywheel Inspection Program RS-19-039, Fleet License Amendment Request - Common Language for Technical Specification High Radiation Area Administrative Controls2019-06-26026 June 2019 Fleet License Amendment Request - Common Language for Technical Specification High Radiation Area Administrative Controls ML19127A0762019-05-0606 May 2019 Application to Revise Technical Specifications to Adopt TSTF-490, Deletion of E-Bar Definition and Revision to RCS Specific Activity Tech Spec ML18239A2602018-08-27027 August 2018 Supplement to Response to Request for Additional Information License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide Risk .. ML18235A1992018-08-23023 August 2018 License Amendment Request: 10 CFR 50.90 Proposed Changes to Technical Specification (TS) 3.8.1 Actions A.3 and D.3 to Extend the Offsite Circuit Inoperable Completion Times from 72 Hours to ... ML18172A1452018-06-21021 June 2018 Response to Request for Additional Information License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide Risk-Informed ... ML18262A0962018-03-0606 March 2018 Technical Specification Bases, Revisions 62 Through 63 ML17261A2342017-07-19019 July 2017 Bases 3.7, Plant Systems, Revisions; B 3.7.1-1 Through B 3.7.18-3 ML17261A2252017-07-19019 July 2017 Bases 3.2, Power Distribution Limits, Revisions; B 3.2.1-1 Through B 3.2.5-5 ML17261A2352017-07-19019 July 2017 Bases 3.8, Electric Power Systems, Revisions; B 3.8.1-1 Through B 3.8.10-5 ML17261A2272017-07-19019 July 2017 Bases 3.3, Instrumentation, Revisions; B 3.3.1-18 Through B 3.3.12-4 ML17261A2212017-07-19019 July 2017 Bases 2.0, Safety Limits, Revision 2; B 2.1.1-1 Through B 2.1.2-4 ML17261A2192017-07-19019 July 2017 Technical Specification Bases ML17261A2312017-07-19019 July 2017 Bases 3.5, Emergency Core Cooling System (Eccs), Revisions; B 3.5.1-1 Through B 3.5.5-5 ML17261A2232017-07-19019 July 2017 Bases 3.1, Reactivity Control Systems, Revisions; B 3.1.1-1 Through B 3.1.8-5 ML17261A2322017-07-19019 July 2017 Bases 3.0, Containment System, Revisions; B 3.0.1-1 Through B 3.0.8-4 ML17261A2292017-07-19019 July 2017 Bases 3.4, Reactor Coolant System(Rcs), Revisions; B 3.4.1-1 Through B 3.4318-8 ML17261A2382017-07-19019 July 2017 Bases 3.9, Refueling Operations, Revisions; B 3.9.1-1 Through B 3.9.6-2 ML17261A2222017-07-19019 July 2017 Basis 3.0, Limiting Condition for Operation (LCO) Applicability, Revisions; B 3.0-1 Through B 3.0-25 ML16266A0862016-09-22022 September 2016 License Amendment Request - Control Room Emergency Ventilation System ML16258A0762016-09-0808 September 2016 Technical Specification Bases B 3.2, Power Distribution Limits - Linear Heat Rate (Lhr) ML16258A0732016-09-0808 September 2016 Technical Specification Bases B 2.1.1-1, Safety Limits ML16258A0772016-09-0808 September 2016 Technical Specification Bases B 3.3.1, Reactor Protective System (RPS) Instrumentation-Operating ML16258A0722016-09-0808 September 2016 Inc. - Technical Specification Bases, Unit Nos. 1 and 2 ML16258A0742016-09-0808 September 2016 Technical Specification Bases B 3.0-1, Limiting Condition for Operation (LCO) Applicability ML16258A0842016-09-0808 September 2016 Technical Specification Bases B 3.9.1, Refueling Operations, Boron Concentration ML16258A0802016-09-0808 September 2016 Technical Specification Bases B 3.5.1, Emergency Core Cooling System (Eccs), Safety Injection Tanks (Sits) ML16258A0812016-09-0808 September 2016 Technical Specification Bases B 3.6, Containment Systems ML16258A0752016-09-0808 September 2016 Technical Specification Bases B 3.1, Reactivity Control Systems ML16258A0832016-09-0808 September 2016 Technical Specification Bases B 3.8.1, Electrical Power Systems, AC Sources-Operating ML16258A0822016-09-0808 September 2016 Technical Specification Bases B 3.7.1, Plant Systems, Main Steam Safety Valves (Mssvs) ML16258A0782016-09-0808 September 2016 Technical Specification Bases B 3.4.1, RCS Pressure, Temperature, and Flow Departure from Nucleate Boiling (DNB) Limits ML16209A2182016-07-26026 July 2016 Application to Revise Technical Specifications to Adopt TSTF-545, Revision 3, TS Lnservice Testing Program Removal & Clarify SR Usage Rule Application to Section 5.5 Testing. ML15257A2002015-09-0404 September 2015 Technical Specification Bases, Revisions 49 Through 55. Part 8 of 12 ML15257A2032015-09-0404 September 2015 Technical Specification Bases, Revisions 49 Through 55. Part 11 of 12 ML15257A1992015-09-0404 September 2015 Technical Specification Bases, Revisions 49 Through 55. Part 7 of 12 ML15257A1982015-09-0404 September 2015 Technical Specification Bases, Revisions 49 Through 55. Part 6 of 12 ML15257A1972015-09-0404 September 2015 Technical Specification Bases, Revisions 49 Through 55. Part 5 of 12 ML15257A1962015-09-0404 September 2015 Technical Specification Bases, Revisions 49 Through 55. Part 4 of 12 ML15257A1952015-09-0404 September 2015 Technical Specification Bases, Revisions 49 Through 55. Part 3 of 12 ML15257A1942015-09-0404 September 2015 Technical Specification Bases, Revisions 49 Through 55. Part 2 of 12 ML15257A1932015-09-0404 September 2015 Technical Specification Bases, Revisions 49 Through 55. Part 1 of 12 ML15257A2022015-09-0404 September 2015 Technical Specification Bases, Revisions 49 Through 55. Part 10 of 12 2024-04-12 Category:Amendment MONTHYEARML24103A2042024-04-12012 April 2024
[Table view]Constellation Energy Generation, LLC, Application to Revise Technical Specifications to Adopt TSTF-591-A, Revise Risk Informed Completion Time (RICT) Program Revision 0 and Revise 10 CFR 50.69 License Condition ML22298A0112022-10-25025 October 2022 License Amendment Request to Adopt Technical Specification Task Force TSTF-295-A, Modify Note 2 to Actions of (Post-Accident Monitoring) PAM Table To. RS-22-086, R. E. Ginna Nuclear Power Plant - Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam.2022-08-10010 August 2022 R. E. Ginna Nuclear Power Plant - Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam. ML19346E5362019-12-11011 December 2019 License Amendment Request: 10 CFR 50.90 Proposed Changes to Technical Specification (TS) 3.8.1 Emergency Diesel Generator Surveillance Requirements for Frequency and Voltage Tolerances ML19325C1282019-11-21021 November 2019 License Amendment Request - Revision to Technical Specification 5.5.7, Reactor Coolant Pump Flywheel Inspection Program RS-19-039, Fleet License Amendment Request - Common Language for Technical Specification High Radiation Area Administrative Controls2019-06-26026 June 2019 Fleet License Amendment Request - Common Language for Technical Specification High Radiation Area Administrative Controls ML19127A0762019-05-0606 May 2019 Application to Revise Technical Specifications to Adopt TSTF-490, Deletion of E-Bar Definition and Revision to RCS Specific Activity Tech Spec ML18239A2602018-08-27027 August 2018 Supplement to Response to Request for Additional Information License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide Risk .. ML18235A1992018-08-23023 August 2018 License Amendment Request: 10 CFR 50.90 Proposed Changes to Technical Specification (TS) 3.8.1 Actions A.3 and D.3 to Extend the Offsite Circuit Inoperable Completion Times from 72 Hours to ... ML18172A1452018-06-21021 June 2018 Response to Request for Additional Information License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide Risk-Informed ... ML16266A0862016-09-22022 September 2016 License Amendment Request - Control Room Emergency Ventilation System ML14191A2552014-07-10010 July 2014 Nine Mile Point and Ginna, Unit 1 - Application to Revise Technical Specifications to Adopt TSTF-523, Generic Letter 2008-01, Managing Gas Accumulation, Using the Consolidated Line Item Improvement Process ML1003405862010-01-29029 January 2010 License Amendment Request: Pressurizer Safety Valve Technical Specification Revision ML0911700492009-04-23023 April 2009 License Amendment Request for Adoption of TSTF-511, Revision 0, Eliminate Working Hour Restrictions from Technical Specification 5.2.2 to Support Compliance with 10 CFR Part 26 ML0821804962008-08-27027 August 2008 Technical Specifications, Amendment No. 288 ML0811601412008-04-23023 April 2008 Tech Spec Pages for Amendments 286 and 263 Modification of Technical Specification Definitions ML0731701802007-11-0808 November 2007 License Amendment Request: Modify Technical Specification Definitions ML0727007162007-09-27027 September 2007 Technical Specification Pages Re Unavailability of Barriers Using Consolidated Line Item Improvement Process ML0718403352007-06-29029 June 2007 License Amendment Request: Revise Technical Specifications Regarding Control Room Habitability in Accordance with TSTF-448 Using the Consolidated Line Item Improvement Process ML0516602072005-06-0707 June 2005 License Amendment Request: Eliminate Use of the Term Core Alterations in the Technical Specifications ML0516601952005-06-0707 June 2005 License Amendment Request: Technical Specification Changes to Modify Requirements Related to Positive Reactivity Additions ML0506002672005-02-24024 February 2005 Technical Specifications, Incorporating Core Operating Limits Analytical Methodology References Into Technical Specifications ML0503904972005-02-0303 February 2005 Technical Specification Pages to Calvert Cliffs, Unit 2 - Correction to Amendment No. 246 ML0503300972005-01-27027 January 2005 License Amendment Request: Change Regarding Mode Using the Consolidated Line Item Improvement Process ML0434400272004-12-0101 December 2004 Application for Technical Specification Improvement to Eliminate Requirements to Provide Monthly Operating Reports and Occupational Radiation Exposure Reports ML0431001302004-11-0303 November 2004 Units 1 & 2; Technical Specification Bases, Revisions 15. 16, 17, 18, 19, 20. 21, and 22 ML0430001872004-10-21021 October 2004 Technical Specification Page for Corrected Amendment Nos. 268 and 244 ML0420200822004-07-15015 July 2004 Units, 1 and 2, License Amendment Request: Incorporate Methodology References for the Implementation of PHOENIX-P, Anc, Paragon, and Zirconium Diboride Into the Technical Specifications ML0416201102004-06-0707 June 2004 Units I & 2, License Amendment Request: Use of Alternate Decay Heat Removal in Mode 6 Refueling ML0416300782004-06-0303 June 2004 License Amendment, Technical Specification Pages Re Spent Fuel Pool Maximum Enrichment Limit ML0335102762003-12-12012 December 2003 License Amendment Request Regarding Elimination of Post-Accident Sampling System (PASS) Sampling Requirements ML0334504822003-12-0909 December 2003 Technical Specification for Calvert Cliff Units 1 & 2, Amendment Nos. 261 & 238 ML0331405792003-09-30030 September 2003 Letter Transmitting Calvert Cliffs, Units 1 and 2 - License Amendment Request: Increase the Unit 2 Spent Fuel Pool Maximum Enrichment Limit with Soluble Boron and Burnup Credit ML0312803252003-05-0101 May 2003 License Amendment Request Re Increase to Spent Fuel Pool Maximum Enrichment Limit with Soluble Boron Credit, Attachment H ML0312703002003-05-0101 May 2003 License Amendment Request Re Increase to Spent Fuel Pool Maximum Enrichment Limit with Soluble Boron Credit, Attachments 1 Through G ML0312803342003-05-0101 May 2003 License Amendment Request Re Increase to Spent Fuel Pool Maximum Enrichment Limit with Soluble Boron Credit, Attachment I Through F ML0312702882003-05-0101 May 2003 License Amendment Request Re Increase to Spent Fuel Pool Maximum Enrichment Limit with Soluble Boron Credit ML0235100562002-12-13013 December 2002 License Amend Request: Removal of Charging Pumps from Emergency Core Cooling System Technical Specification ML0221302562002-07-17017 July 2002 Westinghouse Lead Fuel Assemblies - Temporary Exemption Request & License Amendment Request ML0209904332002-04-0808 April 2002 Technical Specification Pages for Amendments 251 & 228, Calvert Cliffs, Units 1 & 2 ML0209802212002-04-0404 April 2002 Technical Specification, Emergency Amendment 227 One-Time Extension of the Unit 2 Control Room Emergency Ventilation System Technical Specification ML0206406192002-03-0404 March 2002 Technical Specifications, for Amendment Nos. 250 & 256 ML0206302602002-03-0101 March 2002 Technical Specifications, Amendment Steam Generator Replacement (Tac Nos. MB0951 and MB0952) ML0204505342002-02-13013 February 2002 Technical Specifications, Amendment One-Time Extension of the Unit 2 Control Room Emergency Ventilation System Technical Specification 2024-04-12 |
Text
S 3-rules, regulations, and orders of the Commission, now or hereafter applicable; and is subject to.the additional conditions specified and incorporated below:
(1) Maximum Power Level The licensee.is authorized to operate the facility at steady-state reactor core power levels not in excess of 2700 megawatts-thermal in accordance with the conditions specified herein.
(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 288, are hereby incorporated into this license. The licensee shall operate the facility in accordance with the Technical *Specifications.
(a) For Surveillance Requirements (SRs) that are new, in Amendment 227 to Facility Operating License No. DPR-53, the first performance is due at the end of the first surveillance interval that begins at implementation of Amendment 227. For SRs that.
existed prior to Amendment 227, including SRs with modified acceptance criteria and'SRs whose frequency of performance is being extended, .the first performance is due at the end of the first surveillance interval that begins on the date the Surveillance was last performed prior to implementation of Amendment 227.
(3) Additional Conditions The Additional Conditions contained in Appendix C as revised through Amendment No. 267 are hereby incorporated into this license. Calvert Cliffs Nuclear Power Plant, Inc. shall operate the facility in accordance with the Additional Conditions.
(4) Secondary Water Chemistry Monitorinq Pro-qram The Calvert Cliffs Nuclear Power Plant, Inc., shall implement a secondary water chemistry monitoring program to inhibit steam generator tube degradation. This program shall include:
- a. Identification of a sampling schedule for the critical parameters and control points for these parameters;
- b. Identification of the procedures used to quantify parameters that are critical to control points; Amendment No. 288