SDC and Coolant Circulation-Low Water Level 3.9.5 ACTIONS (continued)

CONDITION R

REQUIRED ACTION I COMPLETION TIME B.

(Continued)

B.3.1 Close equipment hatch and secure with a minimum of four bolts, OR B.3.2 Close the containment outage door.

AND 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> 4 hours 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> 4 hours B.4 Close one door in each air lock.

AND B.5.1 Close each penetration providing direct access from the containment atmosphere to the outside atmosphere with a manual or automatic isolation valve, blind flange, or equivalent.

OR CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.9.5-3 Amendment No. 268 Amendment No. 244