CREVS 3.7.8 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME D.

One CREVS train D.1 Restore CREVS train 7 days*

inoperable for to OPERABLE status.

reasons other than Condition A, B, or C in MODE 1, 2, 3, or

4.

E.

Required Action and E.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time of Condition A, AND B, C, or D not met in MODE 1, 2, 3, or 4.

E.2 Be in MODE 5.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> F.

Required Action and F.1 Suspend movement of Immediately associated Completion irradiated fuel Time of Condition B assemblies.

not met during movement of irradiated fuel assemblies.

OR This Action is extended from 7 days to 11 days (for loss of the emergency power supply only) during the Unit 1 2002 Refueling Outage.

This extension begins when the No.

1A Diesel Generator allowed outage time as specified in Technical Specification 3.8.1 expires.

The extension ends when No.

1A Diesel Generator is declared OPERABLE on 4 kV Bus No.

11 under Technical Specification 3.8.1 or 11 days has expired, whichever is first.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.7.8-2 Amendment No.

Amendment No.

223

CREVS 3.7.8 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME F.

(continued)

Required CREVS inoperable for reasons other than Condition B during movement of irradiated fuel assemblies.

G.

Two CREVS trains G.1 Enter LCO 3.0.3.

Immediately inoperable for reasons other than Condition A, B, or C in MODE 1, 2, 3, or 4.

OR One or more ducts with two outside air intake isolation valves inoperable in MODE 1, 2, 3, or 4.

OR Two exhaust to atmosphere i sol ati on valves inoperable in MODE 1, 2, 3, or 4.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS -

UNIT 2 3.7.8-3 Amendment No.

Amendment No. 223

CREVS 3.7.8 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.8.1 Operate each required CREVS filter train for 31 days

Ž 15 minutes.

SR 3.7.8.2 Perform required CREVS filter testing in In accordance accordance with Ventilation Filter Testing with the VFTP Program (VFTP).

SR 3.7.8.3 Verify each CREVS train actuates on an 24 months actual or simulated actuation signal.

CALVERT CLIFFS -

UNIT 1 CALVERT CLIFFS -

UNIT 2 3.7.8-4 Amendment No.

Amendment No.

223