MONTHYEARL-2015-059, 2014 Annual Report of Reactor Coolant Specific Activity Limits2015-02-25025 February 2015 2014 Annual Report of Reactor Coolant Specific Activity Limits L-2014-153, Errata Correction to FPL Letter L-2013-085 Regarding the 2012 Annual Radioactive Effluent Release Report2014-05-21021 May 2014 Errata Correction to FPL Letter L-2013-085 Regarding the 2012 Annual Radioactive Effluent Release Report L-2014-084, 10 CFR 50.46, Acceptance Criteria for Emergency Core Cooling Systems in Light Water Nuclear Power Reactors - 2013 Annual Report and 30-Day Special Report2014-04-16016 April 2014 10 CFR 50.46, Acceptance Criteria for Emergency Core Cooling Systems in Light Water Nuclear Power Reactors - 2013 Annual Report and 30-Day Special Report L-2013-108, 10 CFR 50/46, Acceptance Criteria for Emergency Core Cooling Systems in Light Water Nuclear Power Reactors - 2012 Annual Report2013-04-29029 April 2013 10 CFR 50/46, Acceptance Criteria for Emergency Core Cooling Systems in Light Water Nuclear Power Reactors - 2012 Annual Report L-2007-054, Annual Radioactive Effluent Release Report for the Period January 1, 2006 Through December 31, 20062007-03-29029 March 2007 Annual Radioactive Effluent Release Report for the Period January 1, 2006 Through December 31, 2006 L-2005-260, Price Anderson Guarantees/Annual Financial Report2005-12-29029 December 2005 Price Anderson Guarantees/Annual Financial Report L-2005-096, CFR 50.46, Acceptance Criteria for Emergency Core Cooling Systems in Light Water Nuclear Power Reactors - Annual Report and 30-Day Report2005-04-27027 April 2005 CFR 50.46, Acceptance Criteria for Emergency Core Cooling Systems in Light Water Nuclear Power Reactors - Annual Report and 30-Day Report L-2005-050, 2004 Annual Reports of Occupational Exposure and Reactor Coolant Specific Activity Limits2005-02-25025 February 2005 2004 Annual Reports of Occupational Exposure and Reactor Coolant Specific Activity Limits L-2003-077, Annual Radioactive Effluent Release Report2003-03-24024 March 2003 Annual Radioactive Effluent Release Report L-2003-038, 2002 Annual Reports of Occupational Exposure, and Reactor Coolant Specific Activity Limits2003-02-21021 February 2003 2002 Annual Reports of Occupational Exposure, and Reactor Coolant Specific Activity Limits L-2003-018, CFR50.46, Acceptance Criteria for Emergency Core Cooling Systems in Light Water Nuclear Power Reactors - Annual Report.2003-01-30030 January 2003 CFR50.46, Acceptance Criteria for Emergency Core Cooling Systems in Light Water Nuclear Power Reactors - Annual Report. L-2002-198, 10 CFR 50.59 Report2002-10-0707 October 2002 10 CFR 50.59 Report ML18227E2091978-01-0101 January 1978 Submit Ecological Monitoring of Selected Parameters at the Turkey Point Plant, Annual Report, 1977. ML18227E2081977-08-31031 August 1977 Submit Ecological Monitoring of Selected Parameters at the Turkey Point Plant, Semiannual Report, January - June 1977. ML18227A9911977-02-11011 February 1977 Submit Financial & Statistical Report, Supplement to 1976 Annual Report ML18227A9901977-02-0707 February 1977 Submit Beyond the Crises, Annual Report 1976 ML18227A9921975-11-19019 November 1975 Submit 1974 Annual Report. 2015-02-25
[Table view] Category:Letter type:L
MONTHYEARL-2024-010, Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3)2024-01-25025 January 2024 Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2024-007, Inservice Inspection Program Owner'S Activity Report (OAR-1)2024-01-18018 January 2024 Inservice Inspection Program Owner'S Activity Report (OAR-1) L-2023-173, Quality Assurance Topical Report (FPL-1) Revision 30 Update2023-12-15015 December 2023 Quality Assurance Topical Report (FPL-1) Revision 30 Update L-2023-166, Turkey Points Units 3 and 4, Correction to the 2022 Annual Radioactive Effluent Release Report2023-12-0606 December 2023 Turkey Points Units 3 and 4, Correction to the 2022 Annual Radioactive Effluent Release Report L-2023-172, Supplement to Exemption Request Regarding Enhanced Weapons. Firearms Background Checks. and Security Event Notifications Final Rule2023-11-29029 November 2023 Supplement to Exemption Request Regarding Enhanced Weapons. Firearms Background Checks. and Security Event Notifications Final Rule L-2023-155, Supplement to Response to Request for Additional Information, Revised NextEra Common Emergency Plan, and Revised Site-Specific Emergency Plan Annexes Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-06542023-11-28028 November 2023 Supplement to Response to Request for Additional Information, Revised NextEra Common Emergency Plan, and Revised Site-Specific Emergency Plan Annexes Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, L-2023-146, Part 73 Exemption Request Regarding Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Final Rule2023-11-16016 November 2023 Part 73 Exemption Request Regarding Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Final Rule L-2023-078, License Amendment Request 278, Incorporate Advanced Fuel Products, Extend Surveillance Intervals and 10 CFR 50.46 Exemption Request to Facilitate Transition to 24-Month Fuel Cycles2023-11-15015 November 2023 License Amendment Request 278, Incorporate Advanced Fuel Products, Extend Surveillance Intervals and 10 CFR 50.46 Exemption Request to Facilitate Transition to 24-Month Fuel Cycles L-2023-077, License Amendment Request 277 Updated Spent Fuel Pool Criticality Analysis2023-10-11011 October 2023 License Amendment Request 277 Updated Spent Fuel Pool Criticality Analysis L-2023-110, Response to Requests for Additional Information Regarding License Amendment Request No. 276, Revise Fire Protection Program in Support of Reactor Coolant Pump Seal Replacement Project2023-08-25025 August 2023 Response to Requests for Additional Information Regarding License Amendment Request No. 276, Revise Fire Protection Program in Support of Reactor Coolant Pump Seal Replacement Project L-2023-115, Inservice Inspection Program Owner'S Activity Report (OAR-1)2023-08-21021 August 2023 Inservice Inspection Program Owner'S Activity Report (OAR-1) L-2023-114, Proposed Turkey Point Units 6 and 7; Seabrook Station; Point Beach Units 1 and 2 - Official Service List Update2023-08-17017 August 2023 Proposed Turkey Point Units 6 and 7; Seabrook Station; Point Beach Units 1 and 2 - Official Service List Update L-2023-098, and Point Beach Units 1 and 2 - Response to Request for Additional Information Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22023-08-0707 August 2023 and Point Beach Units 1 and 2 - Response to Request for Additional Information Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 L-2023-094, Response to Requests for Additional Information Regarding License Amendment Request No. 276, Revise Fire Protection Program in Support of Reactor Coolant Pump Seal Replacement Project2023-07-27027 July 2023 Response to Requests for Additional Information Regarding License Amendment Request No. 276, Revise Fire Protection Program in Support of Reactor Coolant Pump Seal Replacement Project L-2023-087, Florida Power & Light/Nextera Energy, Results of the Safety Culture Program Effectiveness Review, March 20, 2023 (ADAMS Accession No. ML22340A452)2023-06-29029 June 2023 Florida Power & Light/Nextera Energy, Results of the Safety Culture Program Effectiveness Review, March 20, 2023 (ADAMS Accession No. ML22340A452) L-2023-086, Request Temporary Suspension of Turkey Point License Amendment Request 274, Reactor Protection System, Engineered Safety Features Actuation System, and Nuclear Instrumentation.2023-06-28028 June 2023 Request Temporary Suspension of Turkey Point License Amendment Request 274, Reactor Protection System, Engineered Safety Features Actuation System, and Nuclear Instrumentation. L-2023-074, Addendum to 2021 Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation Ctsfsi) Financial Assurance Update2023-06-0202 June 2023 Addendum to 2021 Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation Ctsfsi) Financial Assurance Update L-2023-069, Response to Requests for Additional Information Regarding License Amendment Request No. 276, Revise Fire Protection Program in Support of Reactor Coolant Pump Seal Replacement Project2023-05-31031 May 2023 Response to Requests for Additional Information Regarding License Amendment Request No. 276, Revise Fire Protection Program in Support of Reactor Coolant Pump Seal Replacement Project L-2023-072, Preparation and Scheduling of Operator Licensing Examinations2023-05-22022 May 2023 Preparation and Scheduling of Operator Licensing Examinations L-2023-071, NextEra Energy Quality Assurance Topical Report (FPL-1) Revision 29 and Florida Power and Light Company Quality Assurance Program Description for 10 CFR Part 52 Licenses (FPL-2) Revision 11, Annual Submittal2023-05-22022 May 2023 NextEra Energy Quality Assurance Topical Report (FPL-1) Revision 29 and Florida Power and Light Company Quality Assurance Program Description for 10 CFR Part 52 Licenses (FPL-2) Revision 11, Annual Submittal L-2023-061, 2022 Annual Radiological Environmental Operating Report2023-05-12012 May 2023 2022 Annual Radiological Environmental Operating Report L-2023-062, Cycle 33 Core Operating Limits Report2023-04-27027 April 2023 Cycle 33 Core Operating Limits Report L-2023-060, Radiological Emergency Plan, Revision 752023-04-26026 April 2023 Radiological Emergency Plan, Revision 75 L-2023-054, Submittal of Periodic Reports2023-04-12012 April 2023 Submittal of Periodic Reports L-2023-049, Correction to U4R33 Steam Generator Tube Inspection Report2023-03-30030 March 2023 Correction to U4R33 Steam Generator Tube Inspection Report L-2023-021, Units, 1 and 2, Turkey Point, Units 3 and 4, Seabrook Station and Point Beach, Units 1 and 2 - Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update2023-03-28028 March 2023 Units, 1 and 2, Turkey Point, Units 3 and 4, Seabrook Station and Point Beach, Units 1 and 2 - Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update L-2023-028, and Point Beach Units 1 and 2, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2023-03-27027 March 2023 and Point Beach Units 1 and 2, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications L-2023-025, Fleet Relief Request (Frr) 23-01, Proposed Alternative to ASME Section XI Authorizing Implementation of ASME Code Case N-752-12023-03-15015 March 2023 Fleet Relief Request (Frr) 23-01, Proposed Alternative to ASME Section XI Authorizing Implementation of ASME Code Case N-752-1 L-2023-029, and Point Beach Units 1 and 2 Nuclear Property Insurance - 10 CFR 50.54(w)(3)2023-03-10010 March 2023 and Point Beach Units 1 and 2 Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2023-040, Response to Requests for Additional Information (Rals) and Requests for Confirmation of Information (Rc Ls) Following Regulatory Audit of Subsequent License Renewal Application2023-03-0303 March 2023 Response to Requests for Additional Information (Rals) and Requests for Confirmation of Information (Rc Ls) Following Regulatory Audit of Subsequent License Renewal Application L-2023-037, Annual Radioactive Effluent Release Report2023-03-0101 March 2023 Annual Radioactive Effluent Release Report L-2023-017, Radiological Emergency Plan Revision 73 and Revision 7 42023-02-17017 February 2023 Radiological Emergency Plan Revision 73 and Revision 7 4 L-2023-010, Supplemental Information Regarding License Amendment Request 274, Reactor Protection System, Engineered Safety Features Actuation System, and Nuclear Instrumentation System Replacement Project - Submittal of RPS / ESFAS / Nis2023-02-10010 February 2023 Supplemental Information Regarding License Amendment Request 274, Reactor Protection System, Engineered Safety Features Actuation System, and Nuclear Instrumentation System Replacement Project - Submittal of RPS / ESFAS / Nis L-2023-004, Supplemental Information Regarding License Amendment Request 274, Reactor Protection System, Engineered Safety Features Actuation System, and Nuclear Instrumentation System Replacement Project - Submittal of Huma Factors Results2023-01-17017 January 2023 Supplemental Information Regarding License Amendment Request 274, Reactor Protection System, Engineered Safety Features Actuation System, and Nuclear Instrumentation System Replacement Project - Submittal of Huma Factors Results L-2022-185, Turkey Points, Units 3 & 4; Seabrook Station; and Point Beach, Units 1 and 2 - Supplement to License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22022-12-0909 December 2022 Turkey Points, Units 3 & 4; Seabrook Station; and Point Beach, Units 1 and 2 - Supplement to License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 L-2022-181, Response to Request for Additional Information Regarding License Amendment Request for the Technical Specifications Conversion to NUREG-1431, Revision 52022-12-0101 December 2022 Response to Request for Additional Information Regarding License Amendment Request for the Technical Specifications Conversion to NUREG-1431, Revision 5 L-2022-182, Emergency Response Data System (Eros) Changes2022-11-17017 November 2022 Emergency Response Data System (Eros) Changes L-2022-180, CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums2022-11-0909 November 2022 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums L-2022-168, and Point Beach Units 1 and 2 - 10 CFR 50.46 - Emergency Core Cooling System LBLOCA 30-Day Report2022-10-26026 October 2022 and Point Beach Units 1 and 2 - 10 CFR 50.46 - Emergency Core Cooling System LBLOCA 30-Day Report L-2022-171, 10 CFR 50.59(d)(2) Summary Report2022-10-20020 October 2022 10 CFR 50.59(d)(2) Summary Report L-2022-167, Submittal of Periodic Reports2022-10-13013 October 2022 Submittal of Periodic Reports L-2022-166, Response to Request for Supplemental Information Regarding License Amendment Request 274, Reactor Protection System, Engineered Safety Features Actuation System, and Nuclear Instrumentation System Replacement2022-10-0505 October 2022 Response to Request for Supplemental Information Regarding License Amendment Request 274, Reactor Protection System, Engineered Safety Features Actuation System, and Nuclear Instrumentation System Replacement L-2022-149, U4R33 Steam Generator Tube Inspection Report2022-10-0404 October 2022 U4R33 Steam Generator Tube Inspection Report L-2022-160, Station,, Point Beach Units 1 and 2, License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22022-10-0404 October 2022 Station,, Point Beach Units 1 and 2, License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 L-2022-148, Florida Power & Light Company, Comments on NRC Inspection Procedure (IP) 71111.21 N.03, Commercial Grade Dedication2022-09-16016 September 2022 Florida Power & Light Company, Comments on NRC Inspection Procedure (IP) 71111.21 N.03, Commercial Grade Dedication L-2022-151, Evacuation Time Estimate Study2022-09-15015 September 2022 Evacuation Time Estimate Study L-2022-142, Revised Diversity and Defense-In-Depth Evaluation (D3), Framatome Document No. 51-9324096-0042022-08-19019 August 2022 Revised Diversity and Defense-In-Depth Evaluation (D3), Framatome Document No. 51-9324096-004 L-2022-136, Response to Request for Additional Information Regarding Turkey Point Unit 3 Cycle 32 Steam Generator Tube Inspection Report2022-08-12012 August 2022 Response to Request for Additional Information Regarding Turkey Point Unit 3 Cycle 32 Steam Generator Tube Inspection Report L-2022-109, Inservice Inspection Program - Owner'S Activity Report (OAR-1)2022-06-27027 June 2022 Inservice Inspection Program - Owner'S Activity Report (OAR-1) L-2022-076, Subsequent License Renewal Application - Appendix E Environmental Report Supplement 22022-06-0909 June 2022 Subsequent License Renewal Application - Appendix E Environmental Report Supplement 2 2024-01-25
[Table view] |
Text
SApril 16, 2014 L-2014-084 FPL. 10 CFR 50.46 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555-0001 Re: Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 10 CFR 50.46, "Acceptance Criteria for Emergency Core Cooling Systems in Light Water Nuclear Power Reactors" - 2013 Annual Report and 30-Day Special Report
References:
- 1. FPL letter from Michael Kiley to U.S. NRC Document Control Desk, "Turkey Point Units 3 and 4, Docket Nos. 50-250 and 50-251, 10 CFR 50.46, 'Acceptance Criteria for Emergency Core Cooling Systems in Light Water Nuclear Power Reactors' - 2012 Annual Report," L-2013-108, April 29, 2013.
- 2. FPL letter, Michael Kiley to U. S. Nuclear Regulatory Commission, "Turkey Point Unit 4, Docket No. 50-251, 10 CFR 50.46, 'Acceptance Criteria for Emergency Core Cooling Systems in Light Water Nuclear Power Reactors' - 30 Day Special Report," L-2013-032, February 11, 2013.
- 3. FPL letter from Michael Kiley to U.S. NRC Document Control Desk, "Turkey Point Units 3 and 4, Docket Nos. 50-250 and 50-251, 10 CFR 50.46, 'Acceptance Criteria for Emergency Core Cooling Systems in Light Water Nuclear Power Reactors' - 30 Day Special Report," L-2013-237, August 20, 2013.
- 4. FPL letter, M. Kiley to U. S. Nuclear Regulatory Commission, "Turkey Point Units 3 and 4, Dockets Nos. 50-250 and 50-251, 10 CFR 50.46, 'Acceptance Criteria for Emergency Core Cooling Systems in Light Water Nuclear Power Reactors' - 30 Day Special Report,"
L-2014-037 February 18, 2014.
- 5. Westinghouse letter from E. Malek to R. Klein, "Florida Power and Light Company, Turkey Point Units 3 & 4, 10 CFR 50.46 Report for the HOTSPOT Burst Strain Error Correction," NF-FP-14-9, January 31, 2014.
- 6. Westinghouse letter from E. Malek to R. Klein, "Florida Power and Light Company, Turkey Point Units 3 & 4, 10 CFR 50.46 Annual Notification and Reporting for 2013,"
NF-FP-14-50, March 18, 2014.
Florida Power & Light Company 9760 SW 344 St Homestead, FL 33035 r
L-2014-084 Page 2 of 3 10 CFR 50.46 2013 Annual Report 10 CFR 50.46(a)(3)(ii) requires that licensees report to the Commission at least annually the nature of changes to, or errors discovered in, the Emergency Core Cooling System (ECCS) evaluation models (EM), or in the application of such models that affect the peak clad temperature calculation and their effect on the limiting ECCS analysis. Table 1 of the attachment to this letter provides the Florida Power and Light Company (FPL) 10 CFR 50.46 Peak Cladding Temperature (PCT) 2013 reports for Turkey Point Units 3 and 4.
FPL letter L-2013-108 (Reference 1), submitted the 2012 10 CFR 50.46 annual report. The 2012 annual report documented the Extended Power Uprate (EPU) LBLOCA PCT of 2164°F and EPU SBLOCA PCT of 1231 OF for Turkey Point Unit 3. The 2012 annual report documented the Pre-EPU LBLOCA PCT of 1917OF and Pre-EPU SBLOCA PCT of 1689 0 F for Turkey Point Unit 4.
FPL letter L-2013-032 (Reference 2), submitted the 30-day special report updating the Turkey Point Unit 4 LBLOCA and SBLOCA PCTs as a result of EPU implementation. The special report documented an EPU LBLOCA PCT of 2164°F and EPU SBLOCA PCT of 1231'F for Turkey Point Unit 4.
FPL letter L-2013-237 (Reference 3) submitted the Turkey Point Units 3 and 4 30-day special report documenting several errors in the LBLOCA EM for 2013. The LBLOCA PCT reported for Turkey Point Units 3 and 4 was 2115°F with a cumulative change of 71°F. The SBLOCA EM was not affected by the identified errors.
Table 1 of the attachment to this letter provides the Turkey Point Units 3 and 4 2013 Annual Summary listing all the changes and errors identified by Westinghouse in 2013 in the LBLOCA and SBLOCA EMs. Based on Table 1 of the attachment to this letter, the 2013 Turkey Point Units 3 and 4 LBLOCA and SBLOCA PCTs are 2115OF and 1231 OF, respectively. The PCT cumulative changes are 71 OF for LBLOCA and 0 OF for SBLOCA, respectively.
10 CFR 50.46(a)(3)(ii) also requires that a schedule for reanalysis be provided or compliance with the requirements of the regulation be shown if the error is significant. Compliance with 10 CFR 50.46 requirements is demonstrated by total estimated LBLOCA and SBLOCA PCTs of 2115'F and 1231 OF, respectively, both remaining below the limit of 2200 0 F.
10 CFR 50.46 30-Day Special Report FPL letter L-2014-037 (Reference 4) submitted the Turkey Point Units 3 and 4 30-day special report documenting the LBLOCA EM error identified by Westinghouse in 2013 and reported to FPL by letter dated January 31, 2014 (Reference 5). The LBLOCA EM error in the calculation of the burst strain performed by the HOTSPOT code resulted in an estimated PCT impact of
+18 0 F. The LBLOCA PCT reported for Turkey Point Units 3 and 4 was 2133°F with a cumulative change of 89°F due to the EM error. The SBLOCA EM was not affected by the identified errors.
On March 18, 2014 (Reference 6), Westinghouse identified several LBLOCA errors not previously reported. The EM errors had a 0 °F impact in the LBLOCA PCT. Table 2 of the attachment to this letter provides the Units 3 and 4 30-day special report for the LBLOCA EM
L-2014-084 Page 3 of 3 errors identified by Reference 6. The LBLOCA PCT reported for Turkey Point Units 3 and 4 is 2133°F with a cumulative change of 89 0 F due to the EM errors.
10 CFR 50.46(a)(3)(ii) requires that changes to the LBLOCA EM and SBLOCA EM PCTs exceeding 50°F be reported to the NRC within 30 days. In accordance with 10 CFR 50.46(a)(3)(ii), Table 2 of the attachment to this letter meets the 30-day reporting requirement for the LBLOCA EM error not previously reported.
10 CFR 50.46(a)(3)(ii) also requires that a schedule for reanalysis be provided or compliance with the requirements of the regulation be shown if the error is significant. Compliance with 10 CFR 50.46 requirements is demonstrated by total estimated LBLOCA PCT of 2133°F remaining below the limit of 22000F.
Should there be any questions, please contact Robert Tomonto, Licensing Manager, at 305-246-7327.
Very truly yours, Michael Kiley Vice President Turkey Point Nuclear Plant Attachment cc: Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, Turkey Point Plant
Attachment 1 to L-2014-084 Page 1 of 2 TABLE 1 TURKEY POINT UNITS 3 AND 4 LBLOCA AND SBLOCA PCT 2013 ANNUAL
SUMMARY
Peak Cladding Cumulative Temperature Change LBLOCA EPU Evaluation Model (A1,A2) 2152 OF 0 OF
- Temporary Mixed Core Penalty(Al. A2) 12 OF 12 OF Evaluations & Assessments Reported for 201 3 (A3)
- Initial Fuel Pellet Tavg Uncertainty Calculation -54 OF 54 OF
- Heat Transfer Model Error Corrections 0 OF 0 OF
- Heat Transfer Node Initialization Correction 0 OF 0 OF
- Mass Conservation Error Fix 0 OF 0°F
- Split Channel Momentum Equation Correction 0 OF 0 OF
- Changes to Vessel Superheated Steam Properties 0 OF 0 OF
- Update to Metal Density Reference Temperatures 0 OF 0 OF
- Decay Heat Model Error Corrections 0 OF 0°F
- Pipe Exit Pressure Drop Error Correction 0 OF 0 OF
- Revised Heat Transfer Multiplier Distributions +5 OF 5 OF 2013 10 CFR 50.46 Annual Report 2115 OF 71 OF Peak Cladding Cumulative Temperature Change SBLOCA EPU New Evaluation Model (A, A2) 1231 OF 0 OF Evaluations & Assessments Reported for 201 3 (A5)
- SBLOCTA Cladding Strain Requirement for Fuel Rod Burst 0 OF 0 OF
- Evaluation of Error in Former Plate Flow Hole Equivalent Diameters and Upper Support Plate Flow Area 0 OF 0 OF 2013 10 CFR 50.46 Annual Report 1231 OF 0 OF
Attachment to L-2014-084 Page 2 of 2 TABLE 2 TURKEY POINT UNITS 3 AND 4 LBLOCA 30-DAY SPECIAL REPORT Peak Cladding Cumulative Temperature Change LBLOCA 2013 10 CFR 50.46 Annual Report (Table 1) 2115 OF* 71 OF Reported Assessment (A4)
- Error in Burst Strain Application +18 OF 18 OF New Evaluations & Assessments/30-Day Report(AS)
- Grid Heat Transfer Enhancement Calculation 0 OF 0 OF
- Changes to Grid Blockage Ratio and Porosity 0 OF 0 OF
- Vessel Section 7 Mid-Level Elevation Modeling 0 OF 0 OF April 2014 10 CFR 50.46 Report 2133 OF 89 OF
- This PCT includes a 12 OF mixed core penalty which will go away for Unit 3 when Cycle 27 starts in late April 2014 and for Unit 4 when Cycle 28 starts in October 2014.
REFERENCES Al. FPL letter, M. Kiley to U. S. Nuclear Regulatory Commission, "Turkey Point Units 3 and 4, Dockets Nos. 50-250 and 50-251, 10 CFR 50.46, 'Acceptance Criteria for Emergency Core Cooling Systems in Light Water Nuclear Power Reactors'- 2012 Annual Report,"
L-2013-108, April 29, 2013.
A2. FPL letter, M. Kiley to U. S. Nuclear Regulatory Commission, "Turkey Point Unit 4, Docket No. 50-251, 10 CFR 50.46, 'Acceptance Criteria for Emergency Core Cooling Systems in Light Water Nuclear Power Reactors'- 30 Day Special Report," L-2013-032, February 11, 2013.
A3. FPL letter, M. Kiley to U. S. Nuclear Regulatory Commission, "Turkey Point Units 3 and 4, Dockets Nos. 50-250 and 50-251, 10 CFR 50.46, 'Acceptance Criteria for Emergency Core Cooling Systems in Light Water Nuclear Power Reactors' - 30 Day Special Report,"
L-2013-237, August 20, 2013.
A4. FPL letter, M. Kiley to U. S. Nuclear Regulatory Commission, "Turkey Point Units 3 and 4, Dockets Nos. 50-250 and 50-251, 10 CFR 50.46, 'Acceptance Criteria for Emergency Core Cooling Systems in Light Water Nuclear Power Reactors' - 30 Day Special Report,"
L-2014-037 February 18, 2014.
A5. Westinghouse letter from E. Malek to R. Klein, "Florida Power and Light Company, Turkey Point Units 3 & 4, 10 CFR 50.46 Annual Notification and Reporting for 2013," NF-FP 50, March 18, 2014.