NRC INFORMATION NOTICE 95-48: RESULTS OF SHIFT STAFFING STUDY

Addressees

All holders of operating licenses or construction permits for nuclear power

reactors.

Puroose

The U.S. Nuclear Regulatory Commission (NRC) is issuing this information

notice to Inform addressees of the results of the NRC's study conducted as

part of an NRC Office of Nuclear Regulatory Research (RES) project to address

the adequacy of minimum shift staffing levels at nuclear power plants (NPPs).

It is expected that recipients will review the information for applicability

to their facilities and consider actions, as appropriate, to avoid similar

problems. However, suggestions contained in this information notice are not

NRC requirements; therefore, no specific action or written response is

required.

Description of Circumstances

On November 26, 1991, the NRC issued IN 91-77, "Shift Staffing at Nuclear

Power Plants," (Reference 1) to alert licensees to the problems that could

result from inadequate controls to ensure that shift staffing is sufficient to

accomplish all functions required by an event. However, after IN 91-77 was

issued, event follow-up inspections indicated that problems Involving shift

staffing and task allocation continued to occur.

As a result, the NRC continued with further research in this area. This

research included an NRC RES project to address the adequacy of minimum shift

staffing levels through a shift staffing study encompassing all licensee staff

initially needed during an event.

The first component of the shift staffing study (Reference 2) included an

evaluation of the experience and events for which staffing was a contributing

factor and the identification of the primary issues related to NPP shift

staffing levels. Particular attention was given to shift staffing concerns

expressed in recent inspection reports. The corresponding events typically

occurred at power during the backshift. In addition, observation of emergency

preparedness exercises showed that the potential for work overload appeared to

be higher among senior reactor operators and shift supervisors than among

reactor operators. Dominant factors identified in the study were task

allocation and location (including fire brigade support), procedure design, human-system interface, training, and communications.

95100401-1 c1 n;5

1 0 It

PDA

TfE

957- qS^g

95010~

  • J IN 95-48 October 10, 1995 The second component of the shift staffing study (Reference 3) consisted of

detailed, on-site data collection and assessment of the adequacy of current

NPP staffing practices for performing activities necessary for responding to

and mitigating events. This effort was accomplished by a team survey of the

staffing practices at seven NPPs. The two-person research teams, having both

operational and human factors expertise, gathered information on site from

seven voluntary participants representing the four vendor types, the four NRC

regions, single and multi-unit sites, and a variety of plant ages. The teams

used four methods of collecting data: (1) plant documentation review,

(2) table-top talk-throughs of two accident scenarios (a fire leading to a

reactor trip with complications and either a control room fire leading to

evacuation and remote shutdown or a station blackout), (3)

outside control

room walk-throughs of specific tasks related to the scenarios, and (4)

interviews with site personnel from different groups and levels. Findings of

the second component of the study were the folowing:

The licensees surveyed did not use a systematic process for establishing

site-specific shift staffing levels.

The licensees surveyed frequently assigned additional plant-specific

tasks that were not specified by regulation to be performed by licensed

and non-licensed personnel during an event.

Five of the licensees surveyed used licensed personnel to staff the fire

brigade.

The administrative procedures of the licensees surveyed varied

significantly in both the licensed and non-licensed personnel shift

staffing levels and the types of positions staffed. In addition, the

number of non-licensed operators normally used during the backshift

varied greatly.

The radiation protection and chemistry technicians of all the licensees

surveyed had a high workload during the scenarios.

During scenario talk-throughs, similar-vendor licensees made

significantly different decisions, resulting in very different control

room activities and in-plant tasks.

The licensees surveyed were actively engaged in efforts to reduce

operating and maintenance costs, which could result in a reduction in

staff.

Discussion

As stated in IN 91-77, 'The number of staff on each shift is expected to be

sufficient to accomplish all necessary actions to ensure a safe shutdown of

the reactor following an event. Those actions include implementing emergency

operating procedures, performing required notifications, establishing and

maintaining communications with the NRC and plant management, and any

additional duties assigned by the licensee's administrative controls....

Section 50.54(m) of Title 10 of the Code of Federal Regulations

IN 95-48 October 10, 1995 addresses only minimum staffing levels for licensed personnel and does not

address personnel availability for performing all of the necessary actions

specified in the licensee's administrative controls and required by an event."

The licensees surveyed generally staffed to levels greater than those required

by either the regulations or their plant-specific technical specifications for

both licensed and non-licensed personnel. Nevertheless, the results of the

research project described in this IN provide several insights into areas

which could impact the ability to accomplish safety functions following an

event.

This information notice requires no specific action or written response. If

you have any questions about the information in this notice, please contact

one of the technical contacts listed below or the appropriate Office of

Nuclear Reactor Regulation (NRR) project manager.

Dennis M. Crutchfield, Director

Division of Reactor Program Management

Office of Nuclear Reactor Regulation

References

1.

NRC Information Notice 91-77, NShift Staffing at Nuclear Power Plants,"

November 26, 1991.

2.

D. Shurberg et al., 'Identification of Issues Associated with Nuclear

Power Plant Shift Staffing Levels," Task 1 Letter Report, Brookhaven

National Laboratory, July 20, 1994.

(Accession No. 951003074)

2.

S. Haber et al., "Nuclear Power Plant Shift Staffing Levels: Site Data

Collection Report," Letter Report, Brookhaven National Laboratory, February 1995.

(Accession No. 9510030160)

Technical contacts: Jesse Arildsen, NRR

David Desaulniers, NRR

(301) 415-1026

(301) 415-1043

Neal Hunemuller, NRR

(301) 415-1152 Attachment:

List of Recently Issued NRC Information Notices

4jC4

4 e

C

by

%4efr

Arfachment

IN 95-48

October 10, 1995 LIST OF RECENTLY ISSUED

NRC INFORMATION NOTICES

Information

Date of

Notice No.

Subject

Issuance

Issued to

95-47

95-46

95-12, Supp. 1

95-45

95-44

95-43

Unexpected Opening of a

Safety/Relief Valve and

Complications Involving

Suppression Pool Cooling

Strainer Blockage

Unplanned, Undetected

Release of Radioactivity

from the Exhaust Ventilation

System of a Boiling Water

Reactor

Potentially Nonconforming

Fasteners Supplied by

A&G Engineering II, Inc.

American Power Service

Falsification of American

Society for Nondestructive

Testing (ASNT) Certificates

Ensuring Compatible Use of

Drive Cables Incorporating

Industrial Nuclear Company

Ball-Type Male Connectors

Failure of the Bolt-Locking

Device on the Reactor

Coolant Pump Turning Vane

10/04/95

10/06/95

10/05/95

10/04/95

09/25/95

09/28/95

All holders of OLs or CPs

for nuclear power reactors.

Al I

for

holders of OLs or CPs

nuclear power reactors.

All holders of OLs or CPs

for nuclear power reactors.

All holders of OLs or CPs

for nuclear power reactors.

All Radiography Licensees.

All holders of OLs or CPs

for nuclear power reactors

designed by Westinghouse

Electric Corporation (W).

95-42

Commission Decision on the

Resolution of Generic

Issue 23, Reactor Coolant

Pump Seal Failure'

Degradation of Ventilation

System Charcoal Resulting

from Chemical Cleaning of

Steam Generators

09/22/95

All holders of OLs or CPs

for nuclear power reactors.

95-41

09/22/95

All holders of OLs or CPs

for nuclear power reactors.

OL = Operating License

CP = Construction Permit

IN 95-48 October 10, 1995 addresses only minimum staffing levels for licensed personnel and does not

address personnel availability for performing all of the necessary actions

specified in the licensee's administrative controls and required by an event."

The licensees surveyed generally staffed to levels greater than those required

by either the regulations or their plant-specific technical specifications for

both licensed and non-licensed personnel.

Nevertheless, the results of the

research project described in this IN provide several insights into areas

which could impact the ability to accomplish safety functions following an

event.

This information notice requires no specific action or written response.

If

you have any questions about the information in this notice, please contact

one of the technical contacts listed below or the appropriate Office of

Nuclear Reactor Regulation (NRR) project manager.

orig /s/'d by BKGrimes/for

Dennis M. Crutchfield, Director

Division of Reactor Program Management

Office of Nuclear Reactor Regulation

References

1.

NRC Information Notice 91-77, "Shift Staffing at Nuclear Power Plants,"

November 26, 1991.

2.

D. Shurberg et al., "Identification of Issues Associated with Nuclear

Power Plant Shift Staffing Levels," Task 1 Letter Report, Brookhaven

National Laboratory, July 20, 1994.

(Accession No. 951003074)

2.

S. Haber et al., "Nuclear Power Plant Shift Staffing Levels: Site Data

Collection Report," Letter Report, Brookhaven National Laboratory, February 1995.

(Accession No. 9510030160)

Technical contacts:

Jesse Arildsen, NRR

David Desaulniers, NRR

(301) 415-1026

(301) 415-1043

Neal Hunemuller, NRR

(301) 415-1152 Attachment:

List of Recently Issued NRC Information Notices

DOCUMENT NAME: 95-48.IN

TechEd reviewed this document on 9/20/95.

To receive a copy of this document, indicate in the box: 'C'

- Copy without enclosures 'E '

Copy with enclosures 'N

= No copy

OFFICE HHFB/DRCH

HHFB/DRCH

DRCH

NAME

JArildsen*

CThomas*

BBoger*

DATE

09/19/95

09/22/95

09/25/ 95 lOFFICE PCEB/DRPM

PCEB/DRPM

NAME

RKiessel*

AChaffee*

_

_t_

_ff__ieldI

DATE

10/02/95

10/04/95

10/,4 /95

OFFICIAL RECORD COPY

IN 95-xx

October xx, 1995 addresses only minimum staffing levels for licensed personnel and does not

address personnel availability for performing all of the necessary actions

specified in the licensee's administrative controls and required by an event."

The licensees surveyed generally staffed to levels greater than those required

by either the regulations or their plant-specific technical specifications for

both licensed and non-licensed personnel.

Nevertheless, the results of the

research project described in this IN provide several insights into areas which

could impact the ability to accomplish safety functions following an event.

This information notice requires no specific action or written response. If you

have any questions about the information in this notice, please contact one of

the technical contacts listed below or the appropriate Office of Nuclear Reactor

Regulation (NRR) project manager.

References

1.

NRC Information Notice 91-77, "Shift Staffing at Nuclear Power Plants,"

November 26, 1991.

2.

D. Shurberg et al., "Identification of Issues Associated with Nuclear

Power Plant Shift Staffing Levels," Task 1 Letter Report, Brookhaven

National Laboratory, July 20, 1994.

(Accession No. 951003074)

2.

S. Haber et al., "Nuclear Power Plant Shift Staffing Levels: Site Data

Collection Report," Letter Report, Brookhaven National

Laboratory, February 1995.

(Accession No. 9510030160)

Dennis M. Crutchfield, Director

Division of Reactor Program Management

Office of Nuclear Reactor Regulation

Technical contacts: Jesse Arildsen, NRR

David Desaulniers, NRR

(301) 415-1026

(301) 415-1043

Neal Hunemuller, NRR

(301) 415-1152 Attachment:

List of Recently Issued NRC Information Notices

DOCUMENT NAME: G:\\NKH\\SSTAF-R1.BKG

To receive a copy of this document, indicate In the box:

C" -

Copy without enclosures

E

= Copy with enclosures N

= No copy

[OFFICE

JHHFB/DRCH

ADM PUB

HHFB/DRCH

DRCH

NAME

JArildsen*

Tech Editor*

CThomas*

BBoger*

DATE

09/19/95

09/20/95

09/22/95

09/25/95 OFFICE PCEB/DRPM

PCE$o

DRPM

NAME

RKiessel*

lACVW'

DCrutchfield

DATE

10/02/95 lo /q /95

/ /95

OFFICIAL RECORD COPY

IN 95-XX

September xx, 1995 Technical contacts: Jesse Arildsen, NRR

(301) 415-1026

David Desaulnriers, NRR

(301) 415-1043

Neal Hunemuller, NRR

(301) 415-1152 Attachment: List of Recently Issued NRC Information Notices

DISTRIBUTION:

HHFB R/F

BBoger

REckenrode

DDesaulniers

JPersensky

NHunemuller

DOCUMENT NAME: G:\\ARILDSEN\\SSTAF-R1.IN

To receive a copy of this document, indicate In the box: 'C'

Copy without enclosures 'E'

-

Copy with enclosures 'N- No copy

OFFICE lHHFB/DRCH

ADM/PUB

I

HHFB/DRCH

DRCH

NAME

JArildsen

Tech Editor

[CThomas

BBoger

DATE

J/

/95

/

/95

/

/95

/

/95

"V;)is~t y4 P"

J stv'si

blo*>

ii &

t

4

4A

IN 95-XX

September xx, 1995 DISTRIBUTION:

HHFB R/F

BBoger

REckenrode

DDesauln iers

JPersensky

NHunemuller

DOCUMENT NAME: G:\\ARILDSEN\\SSTAF-R1.IN

To

eivacOa

a

eonv

of WNs document. Indicate in the box: 'C =

Cozv without enclosures E-

Copywith enclosures 'N'- No copy

OFFICE HHFB/DRCH I CPUB

1 Q

RH

DRCH

NAME

JArildsenWke

Tech Editor

CT______ __ BBoger

I

DATE

7' i/959

5i

o/95

9

7/r795 OFFICE PCEB/DRPM

PCEBlDRPM

DRPM

NAME

RKWessel

AChaffee

DCruchfield

DATE

/ /95 I /95 I

/95 OFFICIAL RECORD COPY