Information Notice 1992-52, Barriers and Seals Between Mild and Harsh Environments

From kanterella
Jump to navigation Jump to search
Barriers and Seals Between Mild and Harsh Environments
ML031200130
Person / Time
Site: Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Three Mile Island, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant  Entergy icon.png
Issue date: 07/15/1992
From: Rossi C
Office of Nuclear Reactor Regulation
To:
References
IN-92-052, NUDOCS 9207090264
Download: ML031200130 (3)


c-L

UNITED STATES

NUCLEAR REGULATORY COMMISSION

OFFICE OF NUCLEAR REACTOR REGULATION

WASHINGTON, D.C. 20555 July 15, 1992 NRC INFORMATION NOTICE 92-52: BARRIERS AND SEALS BETWEEN MILD

AND HARSH ENVIRONMENTS -

Addressees

All holders of operating licenses or construction permits for nuclear power

reactors.

Purpose

The U.S. Nuclear Regulatory Commission (NRC) is issuing this information

notice to alert addressees to problems that could result from missing or

deteriorated barriers or seals that protect equipment designed to operate in a

mild environment from areas that could have a harsh environment following a

design basis accident (DBA). It is expected that recipients will review the

information for applicability to their-facilities and consider actions, as

appropriate, to avoid similar problems. However, suggestions contained in

this information notice are not NRC requirements; therefore, no specific

action or written response is required.

Description of Circumstances

On April 1, 1992, with the Millstone Nuclear Power Station, Unit 1, in cold

shutdown, the Northeast Nuclear Energy Company (the licensee) performed a

walkdown inspection of the environmental qualification barriers in the

switchgear area. The licensee found a number of postulated steam paths into

the switchgear area, including gaps between floor hatch covers and the

surrounding floors, openings around doors where gasket material was missing, and miscellaneous small gaps and openings. The licensee had previously

performed evaluations for its environmental qualification (EQ) program hut did

not adequately document determinations of the acceptability of barriers or

unsealed openings. The licensee's EQ program also did not establish

procedures to periodically check and replace, as necessary, some of the

gaskets and seals used in the plant to protect equipment from a harsh

environment.

Discussion

In Section 50.49 of Title 10 of the Code of Federal Regulations, the NRC

established requirements for the environmental qualification of electrical

9207090264 -I tiS

i2 \o7;c

II

ItS

P "O 7-// \

C6j

.t:- /

IN 92-52 July 15, 1992 equipment important to safety. Equipment that operates in a "mild"

environment was not included within the scope of the regulation; inherent is

the presumption that "mild" environments do not change into "harsh"

environments. The circumstances described above indicate that some licensees

may not have maintenance procedures to ensure the integrity of seals or

barriers between "harsh" and "mild" environment areas. If safety-related

equipment intended for "mild" environments were operated at more demanding

conditions, it could cause safety concerns.

This information notice requires no specific action or written response. If

you have any questions about the information in this notice, please contact

one of the technical contacts listed below or the appropriate Office of

Nuclear Reactor Regulation (NRR) project manager.

rles E. Rossi, irector

Division of Operational Events Assessment -

Office of Nuclear Reactor Regulation

Technical contacts: H. Walker, NRR

(301) 504-2827 J. Carter, NRR

(301) 504-1153 Attachment: List of Recently Issued NRC Information Notices

. ,, I *I

I t v Ic

I

e

  • A q <

i A,

i. i J;

.,I

  • *,- **..,-

Attachment

IN 92-52 July 15, 1992 LIST OF RECENTLY ISSUED

NRC INFORMATION NOTICES

Information Date of

Notice No. Subject Issuance Issued to

92-51 Misapplication and 07/09/92 All holders of OLs or CPs

Inadequate Testing of for nuclear power reactors.

Molded-Case Circuit

Breakers

92-50 Cracking of Valves in 07/02/92 All holders of OLs or CPs

the Condensate Return for BWRs.

Lines of A BWR Emer- gency Condenser System

92-49 Recent Loss or Severe 07/02/92 All holders of OLs or CPs

Degradation of Service for nuclear power reactors.

Water Systems

92-48 Failure of Exide Batteries 07/02/92 All holders of OLs or CPs

for nuclear power reactors.

t7_ 7

Intent

ional Bypassing 06/29/92 All holders of OLs or CPs

of Automatic Actuation for nuclear power reactors.

of Plant Protective

Features

92-46 Thermo-Lag Fire Barrier 06/23/92 All holders of OLs or CPs

Material Special Review for nuclear power reactors.

Team Final Report Findings, Current Fire Endurance

Tests, and Ampacity Cal- culation Errors

92-45 Incorrect Relay Used in 06/22/92 All holders of OLs or CPs

Emergency Diesel Generator for nuclear power reactors.

Output Breaker Control

Circuitry

92-44 Problems with Westing- 06/18/92 All holders of OLs or CPs

house DS-206 and DSL-206 for nuclear power reactors.

Type Circuit Breakers

92-43 Defective Molded Phen- 06/09/92 All holders of OLs or CPs

olic Armature Carriers for nuclear power reactors.

Found on Elmwood Con- tactors

OL = Operating License

CP = Construction Permit