Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Three Mile Island, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant |
---|
Issue date: |
11/26/1991 |
---|
From: |
Rossi C Office of Nuclear Reactor Regulation |
---|
To: |
|
---|
References |
---|
IN-91-076, NUDOCS 9111200118 |
Download: ML031190405 (5) |
|
Similar Documents at Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Three Mile Island, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant |
---|
Category:NRC Information Notice
MONTHYEARInformation Notice 2020-02, Flex Diesel Generator Operational Challenges2020-09-15015 September 2020 Flex Diesel Generator Operational Challenges ML20225A0322020-09-0303 September 2020 NRC Choice Letter to NAC International with Attached Safety Inspection Report, IR 0721015/2020201, February 24-27, 2020 and July 22, 2020, Inspection of NAC International in Norcross, Georgia Information Notice 2012-09, PWROG-16043-NP-A, Revision 2, PWROG Program to Address NRC Information Notice 2012-09: Irradiation Effects on Fuel Assembly Spacer Grid Crush Strength for Westinghouse and CE PWR Fuel Designs.2019-11-30030 November 2019 PWROG-16043-NP-A, Revision 2, PWROG Program to Address NRC Information Notice 2012-09: Irradiation Effects on Fuel Assembly Spacer Grid Crush Strength for Westinghouse and CE PWR Fuel Designs. Information Notice 2011-20, NRC060 - NRC Information Notice 2011-20: Concrete Degradation by Alkali-Silica Reaction (Nov. 18, 2011)2019-07-24024 July 2019 NRC060 - NRC Information Notice 2011-20: Concrete Degradation by Alkali-Silica Reaction (Nov. 18, 2011) ML19196A2452019-07-15015 July 2019 Public Notice - Sequoyah Nuclear Plant, Unit 2 - Exigent Amendment to Facility Operating License Information Notice 2019-01, Inadequate Evaluation of Temporary Alterations2019-03-12012 March 2019 Inadequate Evaluation of Temporary Alterations ML16028A3082016-04-27027 April 2016 NRC Information Notice; IN 2016-05: Operating Experience Regarding Complications From a Loss of Instrumentation Air Information Notice 2015-05, Inoperability of Auxiliary and Emergency Feedwater Auto Start Circuits on Loss of Main Feedwater Pumps2015-05-12012 May 2015 Inoperability of Auxiliary and Emergency Feedwater Auto Start Circuits on Loss of Main Feedwater Pumps Information Notice 2015-05, Inoperability Of Auxiliary And Emergency Feedwater Auto Start Circuits On Loss Of Main Feedwater Pumps2015-05-12012 May 2015 Inoperability Of Auxiliary And Emergency Feedwater Auto Start Circuits On Loss Of Main Feedwater Pumps Information Notice 2013-20, OFFICIAL EXHIBIT - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143)2013-10-0303 October 2013 OFFICIAL EXHIBIT - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143) Information Notice 2013-20, Official Exhibit - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143)2013-10-0303 October 2013 Official Exhibit - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143) Information Notice 2013-11, OFFICIAL EXHIBIT - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013)2013-07-0303 July 2013 OFFICIAL EXHIBIT - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013) Information Notice 2013-11, Official Exhibit - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013)2013-07-0303 July 2013 Official Exhibit - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013) Information Notice 2010-12, Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Contain2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2010-12, Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Con2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2010-12, Intervenors' Fifth Motion to Amend And/Or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notic2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend And/Or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2012-13, Boraflex Degradation Surveillance Programs and Corrective Actions in the Spent Fuel Pool2012-08-10010 August 2012 Boraflex Degradation Surveillance Programs and Corrective Actions in the Spent Fuel Pool Information Notice 2012-13, Boraflex Degradation Surveillance Programs And Corrective Actions In The Spent Fuel Pool2012-08-10010 August 2012 Boraflex Degradation Surveillance Programs And Corrective Actions In The Spent Fuel Pool Information Notice 2012-11, Age Related Capacitor Degradation2012-07-23023 July 2012 Age Related Capacitor Degradation ML12031A0132012-02-0606 February 2012 U.S. Nuclear Regulatory Commission Investigation Report No. 2-2010-058, Cpn International, Inc Information Notice 2011-19, Licensee Event Reports Containing Information Pertaining to Defects to Basic Components2011-09-26026 September 2011 Licensee Event Reports Containing Information Pertaining to Defects to Basic Components Information Notice 2011-15, Steel Containment Degradation and Associated License Renewal Aging Management Issues2011-08-0101 August 2011 Steel Containment Degradation and Associated License Renewal Aging Management Issues Information Notice 2011-17, Calculation Methodologies for Operability Determinations of Gas Voids in Nuclear Power Plant Piping2011-07-26026 July 2011 Calculation Methodologies for Operability Determinations of Gas Voids in Nuclear Power Plant Piping Information Notice 2011-13, Official Exhibit - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13)2011-06-29029 June 2011 Official Exhibit - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13) Information Notice 2011-13, Official Exhibit - Nys000329-00-Bd01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (Nrc in 2011-13)2011-06-29029 June 2011 Official Exhibit - Nys000329-00-Bd01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (Nrc in 2011-13) Information Notice 2011-13, OFFICIAL EXHIBIT - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13)2011-06-29029 June 2011 OFFICIAL EXHIBIT - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13) Information Notice 2011-04, IN: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 IN: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2011-04, In: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 In: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2011-04, in: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 in: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2010-26, New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-2010-12-30030 December 2010 New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-19 Information Notice 2010-26, New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review2010-12-30030 December 2010 New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-19 Information Notice 2010-26, 2010/12/21-NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-262010-12-21021 December 2010 2010/12/21-NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 ML13066A1872009-12-16016 December 2009 Draft NRC Information Notice 2009-xx - Underestimate of Dam Failure Frequency Used in Probabilistic Risk Assessments ML1007804482009-11-23023 November 2009 Email from Peter Bamford, NRR to Pamela Cowan, Exelon on TMI Contamination Control Event Information Notice 2009-11, NSP000059-Revised Prefiled Testimony of Northard/Petersen/Peterson-NRC Information Notice 2009-112009-07-0707 July 2009 NSP000059-Revised Prefiled Testimony of Northard/Petersen/Peterson-NRC Information Notice 2009-11 Information Notice 2009-10, Official Exhibit - NYS000019-00-BD01- NRC Information Notice 2009-10, Transformers Failures - Recent Operating Experience (Jul. 7, 2009) (NRC in 2009-10)2009-07-0707 July 2009 Official Exhibit - NYS000019-00-BD01- NRC Information Notice 2009-10, Transformers Failures - Recent Operating Experience (Jul. 7, 2009) (NRC in 2009-10) Information Notice 2009-09, Improper Flow Controller Settings Renders Injection Systems Inoperable and Surveillance Did Not Identify2009-06-19019 June 2009 Improper Flow Controller Settings Renders Injection Systems Inoperable and Surveillance Did Not Identify Information Notice 2008-12, Reactor Trip Due to Off-Site Power Fluctuation2008-07-0707 July 2008 Reactor Trip Due to Off-Site Power Fluctuation Information Notice 2008-11, Service Water System Degradation at Brunswicksteam Electric Plant Unit 12008-06-18018 June 2008 Service Water System Degradation at Brunswicksteam Electric Plant Unit 1 Information Notice 2008-04, Counterfeit Parts Supplied to Nuclear Power Plants2008-04-0707 April 2008 Counterfeit Parts Supplied to Nuclear Power Plants Information Notice 1991-09, Counterfeiting of Crane Valves2007-09-25025 September 2007 Counterfeiting of Crane Valves Information Notice 2007-28, Potential Common Cause Vulnerabilities in Essential Service Water Systems Due to Inadequate Chemistry Controls2007-09-19019 September 2007 Potential Common Cause Vulnerabilities in Essential Service Water Systems Due to Inadequate Chemistry Controls Information Notice 2007-29, Temporary Scaffolding Affects Operability of Safety-Related Equipment2007-09-17017 September 2007 Temporary Scaffolding Affects Operability of Safety-Related Equipment Information Notice 2007-14, Loss of Offsite Power and Dual-Unit Trip at Catawba Nuclear Generating Station2007-03-30030 March 2007 Loss of Offsite Power and Dual-Unit Trip at Catawba Nuclear Generating Station Information Notice 2007-06, Potential Common Cause Vulnerabilities in Essential Service Water Systems2007-02-0909 February 2007 Potential Common Cause Vulnerabilities in Essential Service Water Systems Information Notice 2007-05, Vertical Deep Draft Pump Shaft and Coupling Failures2007-02-0909 February 2007 Vertical Deep Draft Pump Shaft and Coupling Failures Information Notice 2006-31, Inadequate Fault Interrupting Rating of Breakers2006-12-26026 December 2006 Inadequate Fault Interrupting Rating of Breakers Information Notice 2006-29, Potential Common Cause Failure of Motor-operated Valves as a Result of Stem Nut Wear2006-12-14014 December 2006 Potential Common Cause Failure of Motor-operated Valves as a Result of Stem Nut Wear Information Notice 2006-29, Potential Common Cause Failure of Motor-operated Valves As a Result of Stem Nut Wear2006-12-14014 December 2006 Potential Common Cause Failure of Motor-operated Valves As a Result of Stem Nut Wear Information Notice 2006-13, E-mail from M. Mclaughlin on NRC, Regarding NRC Information Notice 2006-13: Groundwater Contamination2006-07-13013 July 2006 E-mail from M. Mclaughlin on NRC, Regarding NRC Information Notice 2006-13: Groundwater Contamination 2020-09-03 The following query condition could not be considered due to this wiki's restrictions on query size or depth: <code> [[:Beaver Valley]] OR [[:Millstone]] OR [[:Hatch]] OR [[:Monticello]] OR [[:Calvert Cliffs]] OR [[:Dresden]] OR [[:Davis Besse]] OR [[:Peach Bottom]] OR [[:Browns Ferry]] OR [[:Salem]] OR [[:Oconee]] OR [[:Mcguire]] OR [[:Nine Mile Point]] OR [[:Palisades]] OR [[:Palo Verde]] OR [[:Perry]] OR [[:Indian Point]] OR [[:Fermi]] OR [[:Kewaunee]] OR [[:Catawba]] OR [[:Harris]] OR [[:Wolf Creek]] OR [[:Saint Lucie]] OR [[:Point Beach]] OR [[:Oyster Creek]] OR [[:Watts Bar]] OR [[:Hope Creek]] OR [[:Grand Gulf]] OR [[:Cooper]] OR [[:Sequoyah]] OR [[:Byron]] OR [[:Pilgrim]] OR [[:Arkansas Nuclear]] OR [[:Three Mile Island]] OR [[:Braidwood]] OR [[:Susquehanna]] OR [[:Summer]] OR [[:Prairie Island]] OR [[:Columbia]] OR [[:Seabrook]] OR [[:Brunswick]] OR [[:Surry]] OR [[:Limerick]] OR [[:North Anna]] OR [[:Turkey Point]] OR [[:River Bend]] OR [[:Vermont Yankee]] OR [[:Crystal River]] OR [[:Haddam Neck]] OR [[:Ginna]] OR [[:Diablo Canyon]] OR [[:Callaway]] OR [[:Vogtle]] OR [[:Waterford]] OR [[:Duane Arnold]] OR [[:Farley]] OR [[:Robinson]] OR [[:Clinton]] OR [[:South Texas]] OR [[:San Onofre]] OR [[:Cook]] OR [[:Comanche Peak]] OR [[:Yankee Rowe]] OR [[:Maine Yankee]] OR [[:Quad Cities]] OR [[:Humboldt Bay]] OR [[:La Crosse]] OR [[:Big Rock Point]] OR [[:Rancho Seco]] OR [[:Zion]] OR [[:Midland]] OR [[:Bellefonte]] OR [[:Fort Calhoun]] OR [[:FitzPatrick]] OR [[:McGuire]] OR [[:LaSalle]] OR [[:Fort Saint Vrain]] OR [[:Shoreham]] OR [[:Satsop]] OR [[:Trojan]] OR [[:Atlantic Nuclear Power Plant]] </code>.
[Table view]The following query condition could not be considered due to this wiki's restrictions on query size or depth: <code> [[:Beaver Valley]] OR [[:Millstone]] OR [[:Hatch]] OR [[:Monticello]] OR [[:Calvert Cliffs]] OR [[:Dresden]] OR [[:Davis Besse]] OR [[:Peach Bottom]] OR [[:Browns Ferry]] OR [[:Salem]] OR [[:Oconee]] OR [[:Mcguire]] OR [[:Nine Mile Point]] OR [[:Palisades]] OR [[:Palo Verde]] OR [[:Perry]] OR [[:Indian Point]] OR [[:Fermi]] OR [[:Kewaunee]] OR [[:Catawba]] OR [[:Harris]] OR [[:Wolf Creek]] OR [[:Saint Lucie]] OR [[:Point Beach]] OR [[:Oyster Creek]] OR [[:Watts Bar]] OR [[:Hope Creek]] OR [[:Grand Gulf]] OR [[:Cooper]] OR [[:Sequoyah]] OR [[:Byron]] OR [[:Pilgrim]] OR [[:Arkansas Nuclear]] OR [[:Three Mile Island]] OR [[:Braidwood]] OR [[:Susquehanna]] OR [[:Summer]] OR [[:Prairie Island]] OR [[:Columbia]] OR [[:Seabrook]] OR [[:Brunswick]] OR [[:Surry]] OR [[:Limerick]] OR [[:North Anna]] OR [[:Turkey Point]] OR [[:River Bend]] OR [[:Vermont Yankee]] OR [[:Crystal River]] OR [[:Haddam Neck]] OR [[:Ginna]] OR [[:Diablo Canyon]] OR [[:Callaway]] OR [[:Vogtle]] OR [[:Waterford]] OR [[:Duane Arnold]] OR [[:Farley]] OR [[:Robinson]] OR [[:Clinton]] OR [[:South Texas]] OR [[:San Onofre]] OR [[:Cook]] OR [[:Comanche Peak]] OR [[:Yankee Rowe]] OR [[:Maine Yankee]] OR [[:Quad Cities]] OR [[:Humboldt Bay]] OR [[:La Crosse]] OR [[:Big Rock Point]] OR [[:Rancho Seco]] OR [[:Zion]] OR [[:Midland]] OR [[:Bellefonte]] OR [[:Fort Calhoun]] OR [[:FitzPatrick]] OR [[:McGuire]] OR [[:LaSalle]] OR [[:Fort Saint Vrain]] OR [[:Shoreham]] OR [[:Satsop]] OR [[:Trojan]] OR [[:Atlantic Nuclear Power Plant]] </code>. |
UNITED STATES
NUCLEAR REGULATORY COMMISSION
OFFICE OF NUCLEAR REACTOR REGULATION
WASHINGTON, D.C. 20555 November 26, 1991 NRC INFORMATION NOTICE 91-76: 10 CFR PARTS 21 AND 50.55(e) FINAL RULES
Addressees
All holders of operating licenses or construction permits and vendors for
nuclear power reactors.
Purpose
The U.S. Nuclear Regulatory Commission (NRC) is issuing this information notice
to inform addressees that the NRC has amended its regulations regarding the
reporting of safety defects under Parts 21 and 50.55(e) of Title 10 of the Code
of Federal Regulations (10 CFR Parts 21 and 50.55(e)), as published in the
Federal Register (56 FR 36081) on July 31, 1991. The changes became effective
on October 29, 1991. It is expected that recipients will review the information
for applicability to their facilities and consider actions, as appropriate.
However, no specific action or written response is required.
Discussion
The 10 CFR Parts 21 and 50.55(e) final rules incorporate the Commission's
experience with the existing regulations. The final rules apply to the Com- mission's licensees and to nonlicensees who construct facilities for, or supply
basic components to facilities or activities licensed by the Commission.
The major changes to the 10 CFR Parts 21 and 50.55(e) rules include the
following:
1. Reduced duplication in reporting or evaluation among Parts 21, 50.55(e),
50.72, 50.73, and 73.71.
2. Established uniform time limits for initial notifications and followup
written notifications for Parts 21 and 50.55(e).
3. Established a time limit for transferring information from vendors to
purchasers or affected licensees for purposes of performing evaluations
of deviations and determining reportability under Part 21.
4. Established a consistent definition of "defect" in Parts 21 and 50.55(e).
5. Established consistent standards for the content of Parts 21 and 50.55(e)
reports.
'O1 911 8 Xd&-te &o () Wl - A d/
IN 91-76 November 26, 1991 6. Clarified the definition of "basic component" in Parts 21 and 50.55(e).
7. Clarified the requirements in Parts 21 and 50.55(e) for retaining records.
8. Established time limits for evaluating potential defects and failures to
comply for Parts 21 and 50.55(e).
9. Established channels of communication for the Parts 21 and 50.55(e) initial
verbal notifications as the NRC Operations Center and for the Parts 21 and
50.55(e) followup written notifications as the Document Control Desk, U.S. Nuclear Regulatory Commission, Washington, D.C. 20555.
This information notice requires no specific action or written response. If
you have any questions about the information in this notice, please contact the
technical contact listed below or the appropriate Office of Nuclear Reactor
Regulation (NRR) project manager..
Charles E. Rossi, Director
Division of Operational Events' Assessment
Office of Nuclear Reactor Regulation
Technical contact: -Nancy Campbell, NRR
(301) 492-0836 Attachment: List of Recently Issued NRC Information Notices
)
Attachment
IN 91-76 November 26, 1991 LIST OF RECENTLY ISSUED
NRC INFORMATION NOTICES
Information Date of
Notice No. Subject Issuance Issued to
91-75 Static Head Corrections 11/25/91 All holders of OLs or CPs
Mistakenly not Included for nuclear power reactors.
in Pressure Transmitter
Calibration Procedures
91-74 Changes in Pressurizer 11/25/91 All holders of OLs or CPs
Safety Valve Setpoints for nuclear power reactors.
Before Installation
91-73 Loss of Shutdown Cooling 11/21/91 All holders of OLs or CPs
During Disassembly of High for nuclear power reactors.
Pressure Safety Injection
System Check Valve
91-72 Issuance of a Revision to 11/19/91 All holders of OLs or CPs
the EPA Manual of Protec- for nuclear power reactors.
tive Action Guides and
Protective Actions for
Nuclear Incidents
91-71 Training and Supervision 11/12/91 All NRC medical licensees.
of Individuals Supervised
by an Authorized User
91-70 Improper Installation of 11/4/91 All holders of OLs or CPs
Instrumentation Modules for nuclear power reactors.
91-69 Errors in Main Steam Line 11/1/91 All holders of OLs or CPs
Break Analyses for Deter- for pressurized-water reactors.
mining Containment Parameters
91-68 Careful Planning Signifi- 10/28/91 All holders of OLs or CPs
cantly Reduces the Potential for nuclear power reactors.
Adverse Impacts of Loss of
Offsite Power Events During
Shutdown
OL = Operating License
CP = Construction Permit
IN 91-XX
November xx, 1991 6. Clarified the definition of "basic component" in Part 21 and 50.55(e).
7. Clarified the requirements in Part 21 and 50.55(e) for retaining records.
8. Established time limits for evaluating potential defects and failures to
comply for Part 21 and 50.55(e).
9. Established channels of communication for the Part 21 and 50.55(e) initial
verbal notification as the NRC Operations Center and for the Part 21 and
50.55(e) followup written notification as the Document Control Desk, U.S.
Nuclear Regulatory Commission, Washington, D.C. 20555.
This information notice requires no specific action or written response. If
you have any questions about the information in this notice, please contact the
technical contact listed below or the appropriate Office of Nuclear Reactor
Regulation (NRR) project manager.
Charles E. Rossi, Director
Division of Operational Events Assessment
Office of Nuclear Reactor Regulation
Technical contact: Nancy Campbell, NRR
(301) 492-0836 Attachment: List of Recently Issued NRC Information Notices
Document Name: 10 CFR PARTS 21 & 50 FINAL RUL
- SEE PREVIOUS CONCURRENCES
- OGCB:DOEA:NRFt *RPB:ADM C/OQa .EA:NRR D/DOEA:NRR
NCampbell TechEd CHBer~jjnger CERossi M
11/13/91 11/07/91 11/6/91 11/ /91
IN 91-XX
November xx, 1991 8', (8 ;Esablishnet of time limits for-e~luati-otof-petentia- defects and failures to comrl for Part 21 and 50.55(e).
9 ( ) Etablishment Gf the. communication -channel-s foriPart 21 and 50.55(e) initial verbal notification as the NRC X
Operations Center andjthe Part 21 and 50.55(e follow5up
written notification as the Document Control Desk, U.S-.
Nuclear Regulatory Commission, Washington, D.C. 20555.
This information notice requires no specific action or written response. If
you have any questions about this information notice, please contact the
technical contact below.
Charles E. Rossi, Director
Division of Operational Events Assessment
Office of Nuclear Reactor Regulation
Technical Contact:
Nancy Campbell
49-20836 Attachment:
List of Recently Issued NRC Information Notices
Document: 10 CFR PARTS 21 & 50 FINAL RUL
OGCB:DOEA:NRR RPB:ADM C/OGCB:DOEA:NRR D/DOEA:NRR
NCampbell TechEd 7M 'v) CHBerlinger CERossi
11/1 /91 1 11/ 7/91 Clan 11/ /91 11/ /91 OFFICIAL RECORD COPY
|
---|
|
list | - Information Notice 1991-01, Supplier of Misrepresented Resistors (4 January 1991, Topic: Fitness for Duty, Overspeed)
- Information Notice 1991-02, Brachytherapy Source Management (7 January 1991, Topic: Fitness for Duty, Brachytherapy, Overspeed)
- Information Notice 1991-03, Management of Wastes Contaminated with Radioactive Materials (Red Bag Waste & Ordinary Trash) (7 January 1991, Topic: Fitness for Duty, Brachytherapy)
- Information Notice 1991-04, Reactor Scram Following Control Rod Withdrawal Associated with Low Power Turbine Testing (28 January 1991, Topic: Fitness for Duty)
- Information Notice 1991-05, Intergranular Stress Corrosion Cracking in Pressurized Water Reactor Safety Injection Accumulator Nozzles (30 January 1991, Topic: Fitness for Duty, Hydrostatic, Intergranular Stress Corrosion Cracking, Liquid penetrant)
- Information Notice 1991-06, Lock-up of Emergency Diesel Generator and Load Sequencer Control Circuits Preventing Restart of Tripped Emergency Diesel Generator (31 January 1991, Topic: Fitness for Duty, Brachytherapy, Overspeed)
- Information Notice 1991-07, Maintenance Deficiency Associated with General Electric Horizontal Custom 8000 Induction Motors (4 February 1991, Topic: Fitness for Duty, Brachytherapy)
- Information Notice 1991-08, Medical Examinations for Licensed Operators (5 February 1991, Topic: Brachytherapy)
- Information Notice 1991-09, Counterfeiting of Crane Valves (25 September 2007)
- Information Notice 1991-10, Summary of Semiannual Program Performance Reports on Fithess-For-Duty (FFD) in the Nuclear Industry (12 February 1991)
- Information Notice 1991-12, Potential Loss of Net Positive Suction Head (NPSH) of Standby Liquid Control System Pumps (15 February 1991)
- Information Notice 1991-13, Inadequate Testing of Emergency Diesel Generators (Edgs) (4 March 1991)
- Information Notice 1991-13, Inadequate Testing of Emergency Diesel Generators (EDGs) (4 March 1991)
- Information Notice 1991-14, Recent Safety-Related Incidents at Large Irradiators (5 March 1991, Topic: Fitness for Duty, Coatings, Incorporated by reference, Brachytherapy, Uranium Hexafluoride, Overexposure)
- Information Notice 1991-15, Incorrect Configuration of Breaker Operating Springs in General Electric AK-Series Metal-Clad Circuit Breakers (6 March 1991)
- Information Notice 1991-16, Unmonitored Release Pathways from Slightly Contaminated Recycle and Recirculation Water Systems at a Fuel Facility (6 March 1991, Topic: Fitness for Duty, Brachytherapy)
- Information Notice 1991-17, Fire Safety of Temporary Installation or Services (11 March 1991)
- Information Notice 1991-18, High-Energy Piping Failures Caused by Wall Thinning (18 December 1991, Topic: Feedwater Heater)
- Information Notice 1991-19, Steam Generator Feedwater Distribution Piping Damage (12 March 1991)
- Information Notice 1991-20, Electrical Wire Insulation Degradation Caused Failure in a Safety-Related Motor Control Center (19 March 1991)
- Information Notice 1991-21, Inadequate Quality Assurance Program of Vendor Supplying Safety-Related Equipment (19 March 1991)
- Information Notice 1991-22, Four Plant Outage Events Involving Loss of AC Power or Coolant Spills (19 March 1991)
- Information Notice 1991-23, Accidental Radiation Overexposures to Personnel Due to Industrial Radiography Accessory Equipment Malfunctions (26 March 1991, Topic: Fitness for Duty, Brachytherapy, Overexposure)
- Information Notice 1991-24, Recent Operating Experience Involving Reactor Operation Without a Licensed Reactor Operator or Senior Reactor Operator Present in the Control Room (26 March 1991)
- Information Notice 1991-25, Commercial-Grade Structural Framing Components Supplied As Nuclear Safety-Related Equipment (1 April 1991)
- Information Notice 1991-25, Commercial-Grade Structural Framing Components Supplied as Nuclear Safety-Related Equipment (1 April 1991)
- Information Notice 1991-26, Potential Nonconservative Errors in the Working Format Hansen-Roach Cross-Section Set Provided with Keno and Scale Codes (2 April 1991, Topic: Fitness for Duty, Brachytherapy)
- Information Notice 1991-27, Incorrect Rotation of Positive Displacement Pump (10 April 1991)
- Information Notice 1991-28, Cracking in Feedwater System Piping (15 April 1991)
- Information Notice 1991-29, Deficiencies Identifie During Electrical Distribution System Functional Inspections (15 April 1991)
- Information Notice 1991-30, Inadequate Calibration of Thermoluminescent Dosimeters Utilized to Monitor Extremity Dose at Uranium Processing and Fabrication Facilities (23 April 1991, Topic: Brachytherapy, Uranium Hexafluoride, Depleted uranium)
- Information Notice 1991-31, Nonconforming Magnaflux Magnetic Particle (14AM) Prepared Bath (9 May 1991)
- Information Notice 1991-32, Possible Flaws in Certain Piping Systems Fabricated by Associated Piping and Engineering (15 May 1991, Topic: Hot Short, Intergranular Stress Corrosion Cracking, Liquid penetrant)
- Information Notice 1991-33, Reactor Safety Information for States During Exercises and Emergencies (31 May 1991)
- Information Notice 1991-34, Potential Problems in Identifying Causes of Emergency Diesel Generator Malfunctions (3 June 1991)
- Information Notice 1991-35, Labeling Requirements for Transporting Multi-Hazard Radioactive Materials (7 June 1991)
- Information Notice 1991-36, Nuclear Plant Staff Working Hours (10 June 1991)
- Information Notice 1991-37, Compressed Gas Cylinder Missile Hazards (10 June 1991)
- Information Notice 1991-38, Thermal Stratification in Feedwater System Piping (13 June 1991, Topic: Unanalyzed Condition)
- Information Notice 1991-39, Compliance with 10 CFR Part 21, Reporting of Defects and Noncompliance. (17 June 1991)
- Information Notice 1991-40, Contamination of Nonradioactive System and Resulting Possibility for Unmonitored, Uncontrolled Release to the Environment (19 June 1991)
- Information Notice 1991-41, Potential Problems with the Use of Freeze Seals (27 June 1991)
- Information Notice 1991-42, Plant Outage Events Involving Poor Coordination Between Operations and Maintenance Personnel During Valve Testing and Manipulations (27 June 1991)
- Information Notice 1991-43, Recent Incidents Involving Rapid Increases in Primary-To-Secondary Leak Rate (5 July 1991, Topic: Grab sample)
- Information Notice 1991-45, Possible Malfunction of Westinghouse Ard, Bfd, & Nbfd Relays, & A200 DC & DPC 250 Magnetic Contactors (5 July 1991)
- Information Notice 1991-46, Degradation of Emergency Diesel Generator Fuel Oil Delivery Systems (18 July 1991)
- Information Notice 1991-47, Failure of Thermo-Lag Fire Barrier Material to Pass Fire Endurance Test (6 August 1991, Topic: Safe Shutdown, Fire Barrier)
- Information Notice 1991-48, False Certificates of Conformance Provided by Westinghouse Electric Supply Company for Refurbished Commercial-Grade Circuit Breakers (9 August 1991, Topic: Fire Barrier)
- Information Notice 1991-49, Enforcement of Safety Requirements for Radiographers (15 August 1991, Topic: High Radiation Area, Fire Barrier, Overexposure)
- Information Notice 1991-50, a Review of Water Hammer Events After 1985 (20 August 1991, Topic: Fire Barrier, Water hammer)