IE Insp Rept 50-483/80-16 on 800610-12.No Noncompliance Noted.Major Areas Inspected:Followup of 10CFR50.55(e) Repts & Unresolved Item
ML19330B059
Person / Time
Site: Callaway 
Issue date: 06/24/1980
From: Gallagher E, Knop R, Wescott H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML19330B058 List:
References
50-483-80-16, NUDOCS 8007300157
Download: ML19330B059 (3)


Text

.

'

h U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT

REGION III

Report No. 50-483/80-16 Docket No. 50-483 License No. CPPR-139 Licensee: Union Electric Company P.O. Box 149 St. Louis, MO 63166 Facility Name:

Callaway, Unit 1 Inspection At: Callaway Site, Reform, M0 Inspection Conducted: June 10-12, 1980 Inspectors: H hWVN E.

N

.

8[M//

Approved By:

. C.

n Projects Section 1

'

Inspection Summary Inspection on June 10-12, 1980 (Report No. 50-483/80-16)

Areas Inspected:

Routine announced inspection:

followup of 10 CFR 50.55(e)

reports and unresolved item. The inspection involved a total of 32 inspector-hours by two NRC inspectors.

Results: Of the two areas inspected, no items of noncompliance were identi-fied.

l 8007800 M

,

.

DETAILS Persons Contacted Union Electric Company

  • M. I. Doyne, General Superintendent Construction
  • F. D. Field, QA Manager
  • S. M. Hogan, QA Assistant Engineer
  • K. W. Kuechenmeister, Construction Engineer
  • R. L. Powers, Superintendent Site QA
  • D. F. Schnell, Manager Nuclear Engineering
  • D.

B. Steck, Engineer

  • R. Veatch, QA Assistant Engineer
  • W. H. Weber, Manager Nuclear Construction Daniels International Corporation
  • H.

J. Starr,

  • Denotes those attending the exit meeting.

1.

Licensee Action on Previously Identified Items (0 pen) Infractions (483/77-05-02, 03, and 04) Questionable inspection of embed plates w/ studs. The licensee agreed to tension test and bend test manually welded embed plate studs. Also, load test selected embed plates already installed. These items remain open pending the results of the tests and evaluation of licensee reports. This evalu-ation will be documented in Report No. 50483/83/80-14.

(Closed) 10 CFR 50.55(e) Report dated June 17, 1977 subject:

Honey-combing in tendon access gallery. The inspector reviewed the licen-see's interim report to RIII dated July 15, 1977 and final report dated September 29, 1977. The inspector reviewed correspondence from SNUPPS to Bechtel (SLBE 7-840) dated September 26, 1979 referencing NCR No. 2-0856-C-A and Wiss, Janney, Elstner and Associates, Inc., re-port: " Investigation of Concrete Base Slab at Union Electric Company WJE No. 77401," a sonic examination of the base slab which did not re-veal any voids and review of Bechtel's letter (BLSE-4972) dated Sep-

tember 28, 1977 which states that after suitable repairs of the void areas, the condition of the base slab concrete will have no safety implications. Discussion with QC personnel established that training

)

of vibrator operators in proper use of vibrators hac

'an place and

.

WP-109 was revised.

This item is considered closed.

,

,

-2-

!

-

.

.

!

"*

(Withdrawn) 10 CFR 50.55(e) report dated October 3,1977, subject:

Potential Reactivity of Sand. The inspector reviewed the licensee's memo to file discussing the withdrawal of the 50.55(e) report and a report by a geologist and petrographer consultant, dated January 15, 1978.

It was noted that ASTM C33, paragraph 5.3 allows use of fine aggregate which is potentially deleteriously reactive if cement containing less than 0.6% alkali is used.

This item is considered closed.

(Closed) 10 CFR 50.55(e) report <1ated January 6, 1978, subject:

Missing Support Welds on Boric A:id Transfer Pumps. The inspector reviewed correspondence, Westinghouse to SNUPPS, SNP (UE-253) dated January 31, 1978 and SNP (UE-249', dated January 5, 1979, addressing the missing welds for the boric acid transfer pumps. The inspector visually examined the welds located on the base plate and front mount-ing foot on the pump and found them acceptable.

This item is considered closed.

Exit Interview The inspectors met with the licensee representatives (denoted under Persons Contacted) at the conclusion of the inspection on June 15, 1980.

The inspectors summarized the purpose and findings of the inspection.

The licensee acknowledged the findings reported herein.

<