Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Repts 50-445/89-19 & 50-446/89-19
ML20247E594
Person / Time
Site: Comanche Peak  
Issue date: 07/21/1989
From: Warnick R
Office of Nuclear Reactor Regulation
To: William Cahill
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
References
NUDOCS 8907260227
Download: ML20247E594 (3)


Text

,,

_ _ _ _ _ _ _

,

j

s

.

.

JUL ? I 1989 In Reply Refer To:

Dockets:

50-445/89-19 50-446/89-19 Mr. W. J. Cahill, Jr.

Executive Vice President TU Electric 400 North Olive' Street, Lock Box 81 Dallas, Texas 75201

Dear Mr.'Cahill,

Thank you for your letter dated May 15, 1989, and supplemental letter dated July 14, 1989,'in response to our letter dated April 14, 1989.

As discussed in previous meetings, we considered your first response to the Notice of Violation to lack a necessary evaluation of the adequacy of QC training with respect to the cited examples.

Your supplemental response satisfactorily addressed our concern.

'We have no further questions at this time.

Sincerely, bmCINhL SIG'NED BY H. F. V7ARNTCT R. F. Warnick, Assistant Director for Inspection Programs Comanche Peak Projects Division

Office of Nuclear Reactor Regulation l

l

,

'[ MRunyan:ww IP:CPPD:NRR IP:CPPD:N

' AD:IP:CPPD:NRR HLivermor RWarnick/PEk/

//v7/t/80 7/t1/89 7/2s/89 Wf i

8907260227 890721

/g ADOCK0500g43 i

DR

-__ -

.,

l?,

a ucu

'

q

'pf jg UNIT ED STATES

~* *

g'

g NUCLEAR REGULATORY COMMISSION g

.: p W ASHING TON,0. C. 20555 e

" " * * $~a

'%

JJL ? I 1989 In Reply Refer To:

Dockets:

50-445/89-19 50-446/89-19 Mr. W.

J. Cahill, Jr.

Executive Vice President TU Electric 400 North Olive Street, Lock Box 81

,

Dallas, Texas 75201

Dear Mr. Cahill,

Thank you for your letter dated May 15, 1989, and supplemental letter d.ated July 14, 1989, in response to our letter dated

. April 14, 1989.

As discussed in previous meetings, we considered your first response to the Notice of Violation to lack a necessary evaluation of the adequacy of QC training with respect to the cited examples.

Your supplemental response satisfactorily addressed our concern.

We have no further questions at this time.

Sincerely, RFIDaA R. F. Warnick, Assistant Director for Inspection Programs Comanche Peak Projects Division Office of Nuclear Reactor Regulation j

_ _ ---

-

_ _ - _ _ _

'

+

.' '

' ' ' * *

W. J.

Cahill, Jr.

.

-

cc:

Roger D. Walker TU Electric Manager, Nuclear Licensing c/o Bethesda Licensing TU Electric 3 Metro Center, Suite 610 Skyway Tower Bethesda, Maryland 20814 400 North Olive Street, L.B.

Dallas, TX 75201 E. F. Ottney P. O. Pox 1777 Juanita Ellis Glen Rose, Texas 76043 President - CASE 1426 South Polk Street Joseph F. Fulbright l

Dallas, TX 75224 Fulbright & Jaworski 1301 McKinney Street Susan M. Theisen Houston, Texas 77010 Assistant Attorney General Environmental Protection Division George A. Parker, Chairman P.O. Box 12548, Capitol Station Public Utility Committee Austin, TX 78711-1548 Senior Citizens Alliance of Tarrant County, Inc.

GDS Associates, Inc.

6048 Wonder Drive 1850 Parkway Place, Suite 720 Fort Worth, Texas 76133 Marietta, GA 30067-8237 Jack R. Newman, Esq.

Lanny A. Sinkin Newman & Holtzinger, P.C.

Christic Institute Suite 1000 1324 N. Capitol Street 1615 L. Street N.W.

Washington, DC 20002 Washington, D.C.

20036 Ms. Billie Pirner Garde, Esq.

Garde Law Office 104 East Wisconsin Avenue Appleton, WI 54911 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 William A. Burchette, Esq.

j Counsel for Tex-La Electric

'

Cooperative of Texas Heron, Burchette, Ruckert & Rothwell 1025 Thomas Jefferson St., NW Washington, DC 20007 i

l