IR 05000443/2017003

From kanterella
Jump to navigation Jump to search
Integrated Inspection Report 05000443/2017003 and Independent Spent Fuel Storage Installation Report No. 07200063/2017001
ML17318A012
Person / Time
Site: Seabrook  
Issue date: 11/13/2017
From: Fred Bower
NRC Region 1
To: Nazar M
NextEra Energy Seabrook
References
IR 2017001, IR 2017003
Download: ML17318A012 (26)


Text

November 13, 2017

SUBJECT:

SEABROOK STATION, UNIT NO. 1 - INTEGRATED INSPECTION REPORT 05000443/2017003 AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION REPORT NO. 07200063/2017001

Dear Mr. Nazar:

On September 30, 2017, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Seabrook Station, Unit No. 1 (Seabrook). On November 8, 2017, the NRC inspectors discussed the results of this inspection with Mr. Eric McCartney, Regional Vice President-North Region and other members of his staff. The results of this inspection are documented in the enclosed report.

The NRC inspectors did not identify any findings or violations of more than minor significance.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and the NRC Public Document Room in accordance with 10 CFR 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely,

/RA/

Fred Bower, Chief Reactor Projects Branch 3 Division of Reactor Projects

Docket No.

50-443 License No.

NPF-86

Enclosure:

Inspection Report 05000443/2017003 w/Attachment: Supplementary Information

REGION I==

Docket No:

50-443

License No:

NPF-86

Report No.:

05000443/2017003

Licensee:

NextEra Energy Seabrook, LLC (NextEra)

Facility:

Seabrook Station, Unit No. 1 (Seabrook)

Location:

Seabrook, NH 03874

Dates:

July 1, 2017 through September 30, 2017

Inspectors:

P. Cataldo, Senior Resident Inspector P. Meier, Resident Inspector

A. Ziedonis, Salem Resident Inspector

B. Dionne, Health Physicist O. Masnyk Bailey, Health Physicist D. Lawyer, Health Physicist

Approved By:

Fred Bower, Chief

Reactor Projects Branch 3

Division of Reactor Projects

SUMMARY

IR 05000443/2017003; 07/01/2017 to 09/30/2017; Seabrook; Routine Integrated Inspection

Report.

This report covered a three-month period of inspection by resident inspectors and announced baseline inspections performed by regional inspectors. The NRCs program for overseeing the safe operation of commercial nuclear power reactors is described in NUREG-1649, Reactor Oversight Process, Revision 6.

No findings were identified.

REPORT DETAILS

Summary of Plant Status

Seabrook operated at full power for the entire assessment period, with the exception of a down-power to 94 percent rated thermal power (RTP) on September 15, 2017, to perform scheduled main turbine control valve testing. Documents reviewed for each section of this inspection report are listed in the Attachment.

REACTOR SAFETY

Cornerstones: Initiating Events, Mitigating Systems, and Barrier Integrity

1R01 Adverse Weather Protection

External Flooding

a. Inspection Scope

During the period of August 7 to 11, 2017, the inspectors performed an inspection of the external flood protection measures for Seabrook. The inspectors reviewed the Updated Final Safety Analysis Report (UFSAR), Chapters 2.4.2.2 and 3.4.1, which depicts the design flood levels and areas containing safety-related equipment to identify areas that may be affected by external flooding. The inspectors conducted a general site walkdown of outside areas, the fuel storage building, the control building, and the emergency diesel generator (EDG) building, to ensure that NextEra erected flood protection measures in accordance with design specifications. The inspectors also reviewed operating experience for mitigating external flooding during severe weather to determine if NextEra planned or established adequate measures to protect against external flooding events and, more specifically, that credited operator actions were adequate.

b. Findings

No findings were identified.

==1R04 Equipment Alignment

Partial System Walkdowns (71111.04 - 4 samples)

a. Inspection Scope

==

The inspectors performed partial walkdowns of the following systems:

  • B cooling water tower (CWT) with A CWT OOS on July 13
  • B safety injection (SI) pump during maintenance on CBS-V-47 on September 19

The inspectors selected these systems based on their risk-significance relative to the reactor safety cornerstones at the time they were inspected. The inspectors reviewed applicable operating procedures, system diagrams, the UFSAR, technical specifications (TSs), work orders (WOs), condition reports (CRs), and the impact of ongoing work activities on redundant trains of equipment in order to identify conditions that could have impacted the systems performance of its intended safety functions. The inspectors also performed field walkdowns of accessible portions of the systems to verify system components and support equipment were aligned correctly and were operable. The inspectors examined the material condition of the components and observed operating parameters of equipment to verify that there were no deficiencies. The inspectors also reviewed whether NextEra staff had properly identified equipment issues and entered them into the corrective action program (CAP) for resolution with the appropriate significance characterization.

b. Findings

No findings were identified.

==1R05 Fire Protection

Resident Inspector Quarterly Walkdowns (71111.05Q - 5 samples)

==

a. Inspection Scope

The inspectors conducted tours of the areas listed below to assess the material condition and operational status of fire protection features. The inspectors verified that NextEra controlled combustible materials and ignition sources in accordance with administrative procedures. The inspectors verified that fire protection and suppression equipment was available for use as specified in the area pre-fire plan, and passive fire barriers were maintained in good material condition. The inspectors also verified that station personnel implemented compensatory measures for out of service, degraded, or inoperable fire protection equipment, as applicable, in accordance with procedures.

  • Vital battery rooms (CB-F-1D-A, CB-F-1E-A, CB-F-1F-A, CB-F-1G-A) on July 10
  • PAB 6 (PAB-F-1A-Z, PAB-F-1J-Z, PAB-F-1B-Z) on September 19
  • PAB 7 (PAB-F-1A-Z) on September 19
  • PAB 7 charging pump rooms (PAB-F-1C-A, PAB-F-1D-A, PAB-F-1E-A) on September 19
  • PAB 26 (PAB-F-1A-Z) on September 19

b. Findings

No findings were identified.

1R11 Licensed Operator Requalification Program and Licensed Operator Performance

.1 Quarterly Review of Licensed Operator Requalification Testing and Training

a. Inspection Scope

The inspectors observed licensed operator simulator training on September 14, conducted as just-in-time training for the power changes and main turbine control valve testing that was planned for the next day, September 15. The inspectors evaluated operator performance during the reactivity manipulations associated with boration and dilution activities, as well as control rod manipulations and turbine load changes that are performed to set proper conditions for the control valve surveillance. The inspectors verified completion of risk significant operator actions, including proper reactivity oversight, and use of applicable plant procedures for both reactor and secondary plant controls. The inspectors assessed the clarity and effectiveness of communications, implementation of actions in response to both expected and unexpected alarms throughout the simulator evolution, and the oversight and direction provided by the control room supervisor. Additionally, the inspectors assessed the ability of the crew and training staff to identify and document crew performance problems.

b. Findings

No findings were identified.

.2 Quarterly Review of Licensed Operator Performance in the Main Control Room

a. Inspection Scope

The inspectors observed the control room operators during a pre-job briefing and performance of the quarterly main steam isolation valve (MSIV) partial-stroke testing, conducted on July 26. The briefing included the associated trip risks regarding partial closure testing of MSIVs, applicable heat stress environments for participants, critical step performance, as well as human error reduction techniques during performance of time-critical evolutions during the testing. Also on July 26, the inspectors observed the flushing of EDG jacket water heat exchanger DG-E-42A, which included assessment of procedure use and adherence, and peer checking standards.

The inspectors also observed performance of quarterly main turbine control valve testing, on September 15. This included reactivity manipulations associated with turbine load control adjustments, control rod manipulations, and boration/dilution activities, which were performed to maneuver the plant from 100 percent RTP to approximately 94 percent RTP, and back to 100 percent RTP, for performance of the surveillance. The inspectors observed communications, command and control, management oversight, procedure use and adherence, as well as response to various alarms and operator review of various alarm response procedures.

b. Findings

No findings were identified.

1R12 Maintenance Effectiveness

a. Inspection Scope

The inspectors reviewed the samples listed below to assess the effectiveness of maintenance activities on structure, system, and component (SSC) performance and reliability. The inspectors reviewed system health reports, CAP documents, maintenance WOs, and Maintenance Rule (MR) basis documents to ensure that NextEra was identifying and properly evaluating performance problems within the scope of the MR. For each sample selected, the inspectors verified that the SSC was properly scoped into the MR in accordance with 10 CFR 50.65 and verified that the (a)(2)performance criteria established by NextEra staff was reasonable. As applicable, for SSCs classified as (a)(1), the inspectors assessed the adequacy of goals and corrective actions to return these SSCs to (a)(2). Additionally, the inspectors ensured that NextEra staff was identifying and addressing common cause failures that occurred within and across MR system boundaries.

  • A control room chiller repairs
  • Diesel driven fire pumps
  • Maintenance and control of oil used in safety-related applications (Quality Control)

b. Findings

No findings were identified.

1R13 Maintenance Risk Assessments and Emergent Work Control

a. Inspection Scope

The inspectors reviewed station evaluation and management of plant risk for the maintenance and emergent work activities listed below to verify that NextEra performed the appropriate risk assessments prior to removing equipment for work. The inspectors selected these activities based on potential risk significance relative to the reactor safety cornerstones. As applicable for each activity, the inspectors verified that NextEra personnel performed risk assessments as required by 10 CFR 50.65(a)(4) and that the assessments were accurate and complete. When NextEra performed emergent work, the inspectors verified that operations personnel promptly assessed and managed plant risk. The inspectors reviewed the scope of maintenance work and discussed the results of the assessment with the stations probabilistic risk analyst to verify plant conditions were consistent with the risk assessment. The inspectors also reviewed the TS requirements and inspected portions of redundant safety systems, when applicable, to verify risk analysis assumptions were valid and applicable requirements were met.

  • A RHR breaker maintenance, switchyard work, and service air compressor C work on July 11
  • Unit substation US-63 relay maintenance on July 28
  • Supplemental emergency power system (SEPS) outage during week of August 21
  • SEPS planned work and Bus 6 relay work on September 7

b. Findings

No findings were identified.

1R15 Operability Determinations and Functionality Assessments

a. Inspection Scope

The inspectors reviewed operability determinations for the following degraded or non-conforming conditions based on the risk significance of the associated components and systems:

  • CWT basin high salinity on July 16
  • Containment atmosphere particulate radiation monitor, RM-6526-1, trending above the alert limit on July 18
  • Pressurizer spray loop temperature indicator on August 1 The inspectors evaluated the technical adequacy of the operability determinations to assess whether TS operability was properly justified and the subject component or system remained available such that no unrecognized increase in risk occurred. The inspectors compared the operability and design criteria in the appropriate sections of the TSs and UFSAR to NextEras evaluations to determine whether the components or systems were operable. The inspectors confirmed, where appropriate, compliance with bounding limitations associated with the evaluations. Where compensatory measures were required to maintain operability, the inspectors determined whether the measures in place would function as intended and were properly controlled by NextEra.

b. Findings

No findings were identified.

1R19 Post-Maintenance Testing

a. Inspection Scope

The inspectors reviewed the post-maintenance tests for the maintenance activities listed below to verify that procedures and test activities adequately tested the safety functions that may have been affected by the maintenance activity, that the acceptance criteria in the procedure were consistent with the information in the applicable licensing basis and/or design basis documents, and that the test results were properly reviewed and accepted and problems were appropriately documented. The inspectors also walked down the affected job site, observed the pre-job brief and post-job critique where possible, confirmed work site cleanliness was maintained, and witnessed the test or reviewed test data to verify quality control hold point were performed and checked, and that results adequately demonstrated restoration of the affected safety functions.

  • Troubleshooting activities on the containment isolation valve for containment sump on July 28
  • C vital battery replacement from July 10 to July 30
  • CWT level indicator 6120 replacement on August 4
  • B EFW oil leak repair on August 18
  • CBS-V-47, A train common suction valve to SI pump A/B from refueling water storage tank, thermal overload relay replacement on August 19
  • SEPS outage during the week of August 21

b. Findings

No findings were identified.

1R22 Surveillance Testing

a. Inspection Scope

The inspectors observed performance of surveillance tests and/or reviewed test data of selected risk-significant SSCs to assess whether test results satisfied TSs, the UFSAR, and NextEra procedure requirements. The inspectors verified that test acceptance criteria were clear, tests demonstrated operational readiness and were consistent with design documentation, test instrumentation had current calibrations and the range and accuracy for the application, tests were performed as written, and applicable test prerequisites were satisfied.

Upon test completion, the inspectors considered whether the test results supported that equipment was capable of performing the required safety functions. The inspectors reviewed the following surveillance tests:

  • A RHR surveillance test on July 11 (in-service test)
  • Pressurizer pressure protection channel 4, RC-P-458, operational surveillance test on July 19
  • MSIV quarterly surveillance test on July 26
  • Invar wire measurements in the B RHR vault on August 2

b. Findings

No findings were identified.

RADIATION SAFETY

Cornerstone: Public Radiation Safety

2RS6 Radioactive Gaseous and Liquid Effluent Treatment

a. Inspection Scope

The inspectors reviewed the treatment, monitoring, and control of radioactive gaseous and liquid effluents. The inspectors used the requirements in 10 CFR Part 20, 10 CFR Part 50, Appendix I; TS; Offsite Dose Calculation Manual (ODCM); applicable industry standards; and procedures required by TSs as criteria for determining compliance.

Inspection Planning

The inspectors conducted in-office review of the Seabrook Stations 2016 annual radioactive effluent and environmental reports, radioactive effluent program documents, UFSAR, ODCM, and applicable event reports.

Walk-downs and Observations (1 sample)

The inspectors walked down the gaseous and liquid radioactive effluent monitoring and filtered ventilation systems to assess the material condition and verify proper alignment according to plant design. The inspectors also observed potential unmonitored release points and reviewed radiation monitoring system surveillance records and the routine processing and discharge of gaseous and liquid radioactive wastes.

Calibration and Testing Program (1 sample)

The inspectors reviewed gaseous and liquid effluent monitor instrument calibration, functional test results, and alarm set-points based on National Institute of Standards and Technology calibration traceability and ODCM specifications.

Sampling and Analyses (1 sample)

The inspectors reviewed: radioactive effluent sampling activities, representative sampling requirements; compensatory measures taken during effluent discharges with inoperable effluent radiation monitoring instrumentation; the use of compensatory radioactive effluent sampling; and the results of the inter-laboratory and intra-laboratory comparison program including scaling of hard-to-detect isotopes.

Instrumentation and Equipment (1 sample)

The inspectors reviewed the methodology used to determine the radioactive effluent stack and vent flow rates to verify that the flow rates were consistent with TS/ODCM and UFSAR values. The inspectors reviewed radioactive effluent discharge system surveillance test results based on TS acceptance criteria. The inspectors verified that high-range effluent monitors used in emergency operating procedures are calibrated and operable and has post-accident effluent sampling capability.

Dose Calculations (1 sample)

The inspectors reviewed: changes in reported dose values from the previous annual radioactive effluent release reports; several liquid and gaseous radioactive waste discharge permits; the scaling method for hard-to-detect radionuclides; ODCM changes; land use census changes; public dose calculations (monthly, quarterly, annual); and records of abnormal gaseous or liquid radioactive releases.

Problem Identification and Resolution (1 sample)

The inspectors evaluated whether problems associated with the radioactive effluent monitoring and control program were identified at an appropriate threshold and properly addressed in NextEras CAP.

b. Findings

No findings were identified.

2RS7 Radiological Environmental Monitoring Program

a. Inspection Scope

The inspectors reviewed the Radiological Environmental Monitoring Program (REMP) to validate the effectiveness of the radioactive gaseous and liquid effluent release program and implementation of the Groundwater Protection Initiative (GPI). The inspectors used the requirements in 10 CFR Part 20; 10 CFR Part 40; 10 CFR Part 50 Appendix I; and the sites TSs, ODCM, Nuclear Energy Institute (NEI) 07-07, and procedures required by TSs as criteria for determining compliance.

Inspection Planning

The inspectors reviewed: Seabrook Station annual radiological environmental and effluent monitoring reports; REMP program audits; ODCM changes; land use census; UFSAR; and inter-laboratory comparison program results.

Site Inspection (1 sample)

The inspectors walked down various thermoluminescent dosimeter and air and water sampling locations and reviewed associated calibration and maintenance records. The inspectors observed the sampling of various environmental media as specified in the ODCM and reviewed any anomalous environmental sampling events including assessment of any positive radioactivity results. The inspectors reviewed any changes to the ODCM. The inspectors verified the operability and calibration of the meteorological tower instruments and meteorological data readouts. The inspectors reviewed environmental sample laboratory analysis results, laboratory instrument measurement detection sensitivities, and results of the laboratory quality control program audit, and the inter-and intra-laboratory comparison program results. The inspectors reviewed the groundwater monitoring program as it applies to selected potential leaking SSCs; and 10 CFR 50.75(g) records of leaks, spills, and remediation since the previous inspection.

Groundwater Protection Initiative Implementation (1 sample)

The inspectors reviewed: groundwater monitoring results; changes to the GPI program since the last inspection; anomalous results or missed groundwater samples; leakage or spill events including entries made into the decommissioning files (10 CFR 50.75(g));

evaluations of surface water discharges; and NextEras evaluation of any positive groundwater sample results including appropriate stakeholder notifications and effluent reporting requirements.

Identification and Resolution of Problems (1 sample)

The inspectors evaluated whether problems associated with the REMP were identified at an appropriate threshold and properly addressed in NextEras CAP.

b. Findings

No findings were identified.

OTHER ACTIVITIES

4OA1 Performance Indicator Verification

Mitigating Systems Performance Index (3 samples)

a. Inspection Scope

The inspectors reviewed NextEras submittal of the Mitigating Systems Performance Index for the following systems for the period of July 1, 2016, through June 30, 2017:

  • Emergency alternating current power system (MS06)
  • High pressure injection system (MS07)
  • Heat removal system (MS08)

To determine the accuracy of the performance indicator data reported during those periods, the inspectors used definitions and guidance contained in NEI Document 99-02, Regulatory Assessment Performance Indicator Guideline, Revision 7. The inspectors also reviewed NextEras operator narrative logs, CRs, mitigating systems performance index derivation reports, event reports, and NRC integrated inspection reports to validate the accuracy of the submittals.

b. Findings

No findings were identified.

4OA2 Problem Identification and Resolution

.1 Routine Review of Problem Identification and Resolution Activities

a. Inspection Scope

As required by Inspection Procedure 71152, Problem Identification and Resolution, the inspectors routinely reviewed issues during baseline inspection activities and plant status reviews to verify NextEra entered issues into the CAP at an appropriate threshold, gave adequate attention to timely corrective actions, and identified and addressed adverse trends. In order to assist with the identification of repetitive equipment failures and specific human performance issues for follow-up, the inspectors performed a daily screening of items entered into the CAP and periodically attended CR screening meetings. The inspectors also confirmed, on a sampling basis, that, as applicable, for identified defects and non-conformances, NextEra performed an evaluation in accordance with 10 CFR Part 21.

b. Findings

No findings were identified.

.2 Annual Sample:

Emergency Diesel Generator Jacket Water Heat Exchanger Tube Leaks

a. Inspection Scope

The inspectors performed an in-depth review of NextEras apparent cause evaluation and corrective actions associated with CR 2178517, which documented a tube leak in the B EDG jacket water heat exchanger, in January 2017. In particular, the leak represented a second tube failure event since November 2016 associated with the EDG heat exchanger for new tubes installed in May 2016.

The inspectors assessed NextEras problem identification threshold, cause analyses, extent of condition reviews, compensatory actions, and the prioritization and timeliness of corrective actions to determine whether NextEra was appropriately identifying, characterizing, and correcting problems associated with this issue and whether the planned or completed corrective actions were appropriate. The inspectors compared the actions taken to the requirements of NextEras CAP and 10 CFR Part 50, Appendix B.

b. Findings and Observations

No findings were identified.

NextEra determined the most probable cause of the tube failures was manufacturing defects on a new set of 58 tubes replaced in May 2016. NextEra determined the most likely cause for having a second tube failure in as many months was the failure to perform Eddy Current Testing (ECT), (non-destructive tube analysis), during the November 2016 event failure investigation, which would have identified these manufacturing defects in the tubes replaced in May 2016.

NextEra sent a sample of tubes for lab analysis to confirm that manufacture defects were the cause of the premature tube failures. Temporary corrective actions were performed following the January 2017 tube failure until all the tubes were replaced during the April 2017 outage. The temporary corrective actions included plugging the suspect tubes to prevent contaminating the jacket water. Because the heat transfer area was reduced by plugging the suspect tubes, an evaluation was performed to ensure the B EDG remained operable. No further tube leaks occurred between January and April 2017.

Although the NextEra subject matter expert recommended ECT of the tubes during the November 2016 investigation, it was not performed to minimize 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of unavailability for the B EDG, as the ECT contractor was not immediately available. In hindsight, the evaluation determined that this was not the correct decision as another failure occurred within a relatively short amount of time. However, this did not place Seabrook in undue risk as the leakage that did occur was of insufficient magnitude to render the B EDG inoperable, and the station was timely in addressing the tube failure in January 2017 before the conditions worsened. Corrective actions included a revision to the maintenance procedure that requires ECT on heat exchangers following tube replacement or any repairs affecting the tubing.

The inspectors determined that NextEras evaluation and extent-of-condition reviews were thorough, and the causes were appropriately identified. The inspectors also determined that the corrective actions were reasonable and addressed the tube leaks in the B EDG jacket water heat exchanger.

4OA5 Other Activities

Operation of an Independent Spent Fuel Storage Installation (ISFSI) at Operating Plants (60855, 60855.1)

a. Inspection Scope

During the period of August 14 to 17, 2017, inspectors observed and evaluated Seabrooks loading of the second (No. 2 of 8) dry shielded canister (DSC) (DSC Serial No. FPL/NEXT-32PTH, DFS Component No. 1-DFS-MM-1048-20) associated with their 2017 ISFSI dry cask loading campaign. The inspectors also reviewed NextEras planned activities related to long-term operation and monitoring of the ISFSI. The inspectors verified compliance with the Certificate of Compliance (CoC), TSs, applicable regulations, and station procedures.

The inspectors observed fuel assemblies being loaded into the DSC. The inspectors observed the movement of the transfer cask into the spent fuel pool (SFP) and movement of the loaded DSC from the SFP into the seismic restraint. The inspectors also observed DSC processing operations including: welding, non-destructive weld examinations, draining, vacuum drying, pressure testing, helium backfill, decontamination, and surveying. During performance of these activities, the inspectors verified that procedure use, communication, and coordination of ISFSI activities met established Seabrook standards and requirements.

The inspectors reviewed Seabrooks program associated with fuel characterization and selection for storage. The inspectors reviewed the second cask fuel selection package to verify that NextEra was loading fuel in accordance with the CoC, TS, and procedures.

The inspectors reviewed a recording of the fuel assemblies loaded into the second DSC to verify the loading was in accordance with the applicable loading plan.

The inspectors observed radiation protection technicians as they performed surveys and provided job coverage for the cask loading workers. The inspectors reviewed selected survey data maps and radiological records from the first and second DSC loading to confirm that radiation survey levels were within limits specified by the TS and consistent with values specified in the final safety analysis review.

The inspectors toured the ISFSI pad to assess the material condition of the pad and the horizontal storage modules (HSM). The inspectors also verified that transient combustibles were not being stored on the ISFSI pad or the vicinity of the HSMs.

The inspectors reviewed corrective action reports and the associated follow-up actions that were generated to ensure that issues were entered into the CAP, prioritized, and evaluated commensurate with their safety significance.

b. Findings

No findings were identified.

4OA6 Meetings, Including Exit

On November 8, 2017, the inspectors presented the inspection results to Mr. Eric McCartney, Regional Vice President-North Region, and other members of the Seabrook Station staff. The inspectors verified that no proprietary information was retained by the inspectors or documented in this report.

ATTACHMENT:

SUPPLEMENTARY INFORMATION

KEY POINTS OF CONTACT

Licensee Personnel

E. McCartney, Regional Vice President-North Region
C. Domingos, Plant General Manager
K. Barry, Assistant Operations Manager
J. Berg, Chemistry/Environmental Supervisor
K. Boehl, ALARA Specialist
K. Browne, Licensing Manager
B. Bryant, Work Management Director
K. Cetto, Cask Loading Lead, TN
M. Collins, Engineering Director
J. Connelly, Shift Manager
D. Currier, EP Manager
S. Folsom, Supt. Maintenance Programs
J. Geddings, TN Management
A. Giotas, Sr. Chemistry Engineer
G. Goncarous, Staff Chemist
R. Guthrie, Sr. Chemistry Engineer
H. Ham, Maintenance Supervisor
R. Harrsch, Operations Director
D. Hickey, RP Supervisor
B. Holman, Manager Construction
G. Hoxie, Manager, Nuclear Projects
J. Isakson, TN Management
D. Low, QA/QC Inspector
P. Malenfant, Senior Analyst
G. Mikos, Project Manager
M. Nadeau, RP Analyst
K. Randall, Reactor Engineering Supervisor
D. Robinson, Chemistry Manager
T. Smith, RP Supervisor
D. Strand, Radiation Protection Manager
C. Thomas, Sr. Licensing Engineer
S. Ting, Chemistry Engineer
P. Waite, Work Package Coordinator, TN Americas, LLC (TN)
R. Weaton, Maintenance Manager
M. Williams, Project Coordinator, TN

LIST OF ITEMS OPENED, CLOSED, DISCUSSED, AND UPDATED

Opened/Closed

None

Opened

None

Closed

None

LIST OF DOCUMENTS REVIEWED