M 0 31988 System Energy Resources, Inc.
MTTN: Mr. O. D. Kir.gsley, Jr.
Vice Presiden?., Nuclear Operations P. O. Box 23054 Jackson, MS -39205 Gentlemen:
SUBJECT: REPORT NO. 50-416/87-27 Thank you for your response of February 10, 1988, to our Notice of Deviation issued on January 11, 1988, concerning activities conducted at your Grand Gulf facility.
Your response adequately discusses corrective action for the deviation.
However, your discussion of reasons for the deviation required clarification, which we obtained from M. Crawford in a telephone conversation on February 23, 1988.
He explained that the Licensing Commitment Tracking System requires that positive feedback be obtained before closing an item.
For the particular item in question, however, en incorrect due date was assigned, and, therefore, failure to meet the commitment due 6 ate was not highlighted or flagged by the system.
We will examine the implementation of your corrective actions during future inspections.
We appreciate your cooperation in this matter.
Sincerely, Alan R. Herdt, Chief Engineering Branch Division of Reactor Safety cc:
IP.' H. Cloninger, Vice President, Nuclear Engineering and Support W E. Cross, GGNS Site Director
& R. Hutchinson, GGNS General Manager WG. Cesare, Director. Nuclear Licensing-f' T. Lally, Manage of Quality Assurance Middle,outh Services.
Inc.
& B. McGehee, Esquire Wise, Carter, Child, Steen and Caraway 4tf S. Reynolds, Esquire Bishop. Cook, Purcell & Reynolds
- .W, Jackson,ProjectEngineer bec:
(See page 2)
8803150352 800303 PDR ADOCK 05000416
\\\\
G PDR Ikol
,
1953 MAR 0 3 o
System Energy Resources, Inc.
bec:.NRC Resident Inspector DRS Technical Assistant K. Kintner, NRR Document Control Desk State of Mississippi Rf1 jf/Fli[*"
}g[
'
RIIg 711 RII R1
'-
,
q) "
I.t FJape HDance GJ s
PFillion:er
'
' 07G7F fr g/88 05/ / /88 03/cl/88 ep/a g
/