IR 05000412/1985002
| ML20129E604 | |
| Person / Time | |
|---|---|
| Site: | Beaver Valley |
| Issue date: | 05/14/1985 |
| From: | Ebneter S NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Woolever E DUQUESNE LIGHT CO. |
| References | |
| NUDOCS 8506060548 | |
| Download: ML20129E604 (2) | |
Text
r
,
4 } '.-
74
.
.
-
MAY 141985'
Docket No.' 50-412.
-Duquesne Light Company
' ATTN: Mr. E. J. Woolever
'
Vice President Nuclear-Construction
. Robin' son Plaza Building No. 2 Suite #210, PA Route 60 Pittsburgh, Pennsylvania 15205
'
Gentlemen:-
Subject: -Inspection Report No. 50-412/85-02 This-refers to your-letter dated April 22, 1985, in response to our letter r
. dated March 22,'1985.
'
Thank you for Informing us of the corrective and preventive actions documented in your letter. These actions will be examined during a future inspection of
.
your licensed program.
Your cooperation with us is~ appreciated.
Sincerely,
")
hW s
b
,
S art bneter, Director
.
Division o Reactor Safety
'cc w/ encl:
E. J. Woolever, Vice President, Nuclear Construction Division E. Ewing, Quality Assurance Manager R. J. Swiderski, Manager, Startup Group
.R. E. Martin, Manager, Engineering-E. F. Kurtz, Jr., Manager, Regulatory Affairs P. - RaySircar, Stone and Webster Engineering Corporation Public Document Room (PDR)
Local Public Document' Room (LPDR)
Nuclear Safety Information Center (NSIC)
NRC Resident Inspector Commonwealth of Pennsylvania OFFICIAL RECORD COPY-RL BV2 85-02 - 0001.0.0
,
05/09/85
~B506060548 850514 fl~4/,1-1 PDR ADOCM 05000412 l..
-O PDR j
-.
.--
~
.-
-
,
.
.
Duquesne Light Company.
'2
)
..,.
bec w/ enc 1:
Region I Docket Room '(with concurrences)~
,
Senior Operations Officer (w/o enc 1)_
DRP Section Chief-
?J. Grant, DRP.
.
- .
'
i
.
.
i
RI:DRS RI:DRS-RI:DRS RI:DRS Gray /mmb Kortas Wiggi Durr 5 / 13 / 8 5 5/
/85 5/n/85 ffgk cic 4 ID
-
-
0FFICIAL RECORD' COPY RL BV2 85-02 - 0001.1.0 05/09/85
.
w-,,,-
m
.
.
-
'Af
'I-Ii
412 787 5
==
==:=;1. 2,0
~,l 22, A ri 1985 P
Pittsburgh, PA 15205 United States Nuclear Regulatory Conunission Region I 631 Park Avenue King of Prussia, PA 19406 ATTENTION:
Mr. Richard W. Starostecki Division of Project and Resident Programs SUBJECT:
Beaver Valley Power Station - Unit No. 2 Docket No. 50-412 USNRC IE Inspection Report No. 40-412/85-02 REFERENCE: NRC Inspection Report 85-02 to Mr. E. J. Woolever dated March 22, 1985 Gentlemen:
This is in response to the Notice of Violations cited in Inspection No. 50-412/85-02 and listed in Appendix A (Notice of Violation) attached to your letter to Mr. E. J. Woolever, dated March 22, 1985.
A.
Notice of Violation 10CFR50, Appendix B,
Criterion V, requires that activities af fecting quality shall be prescribed by procedures or drawings.
The Beave r Valley Power Station Unit 2 (BVPS-2) FSAR, Section 17.1, Quality Assurance during Design and Construction, which refers back to BVPS PSAR Section 17.2.1.5A, Instructions, Procedures and Drawings, requires that activities af fect ing quality shall be presc ribed by documented procedures and drawings.
The BVPS-2 Field Cons t ruc *. ion Procedure No. FCP-302 requires that an As sembly/Disas sembly repo rt be issued for authorized valve work.
Contrary to the above, on January 22, 1985, the installed valve VCW-150-X2 (V-115) on line 2-SIS-010-10-2 was found with loose nuts including one missing nut on the shaft seal plates.
The documentation for the valve has been signed of f by QC inspection as complete.
It was determined that no Assembly / Disassembly Report was issued for the installation changes of shaft seal plate covers; thus, indicating ut.athorized or incomplete work had been accomplished.
Corrective Actions Nonconformance and Disposition (N&D) 7934 has been generated for the subject valve and a replacement nut is now being obtained in accordance
,h,}r%/ bc n-:x _
-
7 s 7,
-
.,
U;itcd Stctco Nuc1Gcr Reguictory Commiscien
.
,
Mr. Richced W. Stcrcotceki
.
USNRC IE Inapection Riport No. 50-412/85-02 Page 2 with ASME XI Code requirements.
Upon receipt, the nut will be installed and the tightness of all the shaf t seal nuts will be verified. This work is currently scheduled to be complete by July 1985.
In order to prevent any future occurrence of unauthorized rework the following has been done.
The mechanical and electrical contractors have been instructed to ensure that their personnel are thoroughly familiar and working in compliance with the requirements of the site rework control program.
Failure to comply with the program will lead to disci-plinary action.
Duquesne Light Company's Architect Engineer, Stone and Webster, will provide manageme nt control to ensure ' adherence to the requirements of the rework control program.
B.
Notice of Violation 10CFR50, Appendix B, Criterion IX, requires nondestructive testing to be controlled and accomplished in accordance with applicable codes, stan-dards, specifications, criteria, and other special requirements.
The drawing 883D683 for the Reactor Vessel Internals Energy Absorber Assembly requires penetrant it.spection of the upper weld to quality level
"B" defined in W PS 595139.
Quality Level
"B" prohibits cracks or other linear indications. This component was fabricated and considered accept-able prior to shipment to the field for installation.
Contrary to the above, on January 24, 1985, the NRC initiated liquid penetrant inspection of this shop weld on component K468A02 disclosed linear indications exceeding the limits of Quality Level
"B".
Corrective Actions Upon Notification of the inspector's concern, a liquid penetrant examina-tion was performed in accordance with DLC's Procedure PT-10, revision date January 17, 1984.
The examination conducted according to this rejection criteria being procedure was performed without acceptance or applied since DLC's NDE Inspectors were not qualified for the W procedure quot ed in the Inspector's report.
The results of this examTnation are shown on NDE Report #111465.
In summary, within the 1-1/4" area of interest selected by the Inspector, four (4) discontinuities were discovered, ranging in size from 1/32" to 3/16"; the 3/16" indication was blotched.
Following this examination, W initiated Field Deficiency Report DMWM-10132 to document the event and to track any subsequent activities.
l It was established that the equipment supplier was W Pensacola Division
_
in Florida; and, following instructions, W researched their shop records and retrieved the original LP Inspection Instructions / Recording Form that identified the piece by serial number.
The report has evidence of the NDE Inspector's stamp of acceptance, dated August 10, 1976.
_.
,_, _.-
__
_
.. _.
_
,
_
- - - -
-
U ltcd Stctco Euclocr Regulctcry Coussisaien
~,
_e Mr. Richnrd W,-Stcrostceki
'
USNRC IE In pectien ~R p3rt No. 50-412/85-02 Page 3 During this investigation, it was further established that the procedure-in use at the time was W Quality Inspection Procedure #8100, Revision 1.
A level III Examiner from the manufacturer attended the site and repeated the LP examination utilizi:3 the referenced original procedure.
The
-
examiner evaluated the results against that procedure and found them acceptable.
Following this examination, a light buffing was applied to the area of interest and the LP examination was repeated, with acceptable results.
,
The details of these inspections are described in W letters QE-85-030 and
~
QE-85-031, respectively.
The associated documentation and the disposi-tioned W Field Deficiency Repo rt are available to the NRC Resident Inspectol for review at the site as required.
As noted in the Inspector's report, the original conce.rn was obtained by visual examination; and, in consequence, an informal visual examination of the remaining three similar welds was performed by W personnel with no evidence of surface discontinuities.
Based on this action, it is con-sidered that in addition to the LP examinations being evaluated as acceptable, this type of visual discontinuity was an isolated case.
DUQUESNE LIGHT COMPANY s
By
-
/
'
'
J. J. Cfrey /\\ f Vic e,yf es ideht'
JS/wjs cc:
Mr. R. DeYoung, Director (3)
Mr. B. K. Singh, Project Manager Mr. G. Walton, NRC Resident Inspector INPO Records Center NRC Document Control Desk SUBSCRIBED AND S RN TO,BEFORE ME THIS d42[ DAY OF A (_
, 1985.
'
Notary Public ANITA ELAINE REITER, NOTARY PUBLIC ROBINSON TOWNSHIP, ALLEGHENY COUNTY MY COMMISSION EXPlRES OCTOBER 20,1986
. _ _
[
..
Unitcd SectGo Nuc100r Rigulctcry Cosmicaicn
+
,
,
Mr. Rich rd W. Stcrsatscki
USNRC IE In3piction Rrport No. 50-412/85-02
-
Page 4
.
COMMONWEALTH OF PENNSYLVANIA )
)
SS:
COUNTY OF ALLEGHENY
>
The Manager, Regulatory Affairs, E.
F.
Kurtz, Jr.,
being first duly sworn, deposes, and says:
that he is Manager, Regulatory Affairs, of Duquesne Light Company, with legal authority to sign of ficial correspondence on behalf of the Vice President, Nuclear Division, J. J. Carey, in relation to licensing for Beaver Valley Power Station, Unit 2,
and is therefore authorized to submit the foregoing on behalf of the applicant. knowledge.