IR 05000395/1993009

From kanterella
Jump to navigation Jump to search
Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-395/93-09
ML20046C271
Person / Time
Site: Summer 
Issue date: 08/02/1993
From: Verrilli D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Skolds J
SOUTH CAROLINA ELECTRIC & GAS CO.
References
NUDOCS 9308100070
Download: ML20046C271 (2)


Text

.-

.

.

.,.e

.

AUG - 21993 y

.V

.

&

)Y'

Docket No.:

50-395 (\\y'

License No.:

NPF-12 South Carolina Electric & Gas Company ATTN: Mr. John L. Skolds Vice President, Nuclear Operations Virgil C. Summer Nuclear Station P. O. Box 88 Jenkinsville, SC 29056 Gentlemen:

SUBJECT: REPORT NO. 50-395/93-09 Thank you for your response of July 23, 1993, to our Notice of Violation, issued on April 21, 1993, concerning activities conducted at your V. C. Summer facility. We have evaluated your response concerning Violation A which was granted an extension on the due date, and found that it meets the requirements of 10 CFR 2.201. We will examine the implementation of your corrective actions during future inspections We appreci de your cooperation in this matter.

Sincerely, Original signed by:

Harold O. Christensen/for David M. Verrelli, Chief Reactor Projects Branch 1 Division of Reactor Projects -

cc:

R. J. White Nuclear Coordinator S.C. Public Service Authority Virgil C. Summer Nuclear Station P. O. Box 88 (Mail Code 802)

Jenkinsville, SC 29065 G. J. Taylor, General Manager Nuclear Plant Operations South Carolina Electric & Gas Co.

Virgil C. Summer Nuclear Station P. O. Box 88 (Mail Code 300)

Jenkinsville, SC 29065 (cc cont'd - See page 2)

9308100070 930802 PDR ADOCK 0S000395 fh G

PDR fsol

.

,..

.

,

-

,

.

.

'

.:q

,o.

.

?

l South Carolina Electric &

-

Gas Company y

(cc cont'd)

.

J. B. Knotts, Jr., Esq.

Bishop, Cook, Purcell

'

and Reynolds

1400 L Street, NW e

Washington, D. C.

20005-3502

,

Chairman

Fairfield County Council P. O. Drawer 60 Winnsboro, SC 29180

'

Heyward G. Shealy, Chief

Bureau of Radiological Health S. C. Department of Health and Environmental Control

2600 Bull Street i

Columbia, SC 29201 l

Mr. R. M. Fowlkes, Manager Nuclear Licensing and Operating Experience South Carolina Electric & Gas Comptny l

Virgil C. Summer Nuclear Statien j

P. O. Box 88

'

Jenkinsville, SC 29065-bec: G. F. Wunder, NRR F. Cantrell, RII

,

S. Vias,.RII

'

Document Control Desk

NRC Resident Inspector U.S. Nuclear Regulatory Commission Route 1, Box 64 Jenkinsville, SC 29065 i

,

i

RII:DRP RII:DRP

%,J

$4

'

RWright:tj FCantrell 08/2 /93 08/7/93

?

i

,