IR 05000334/1990005

From kanterella
Jump to navigation Jump to search
Combined Insp Repts 50-334/90-05 & 50-412/90-04 on 900129. Violations Noted.Major Areas Inspected:Review of Circumstances Surrounding Shipment of Scaffolding to Quadrex Recycle Ctr,Oak Ridge,Tn on 900110
ML20006C364
Person / Time
Site: Beaver Valley
Issue date: 01/30/1990
From: Bores R, Joseph Furia
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20006C359 List:
References
50-334-90-05, 50-334-90-5, 50-412-90-04, 50-412-90-4, NUDOCS 9002070388
Download: ML20006C364 (2)


Text

(

.p

.

]

'.

'

'

.

..

'

NUCLEAR REGULATORY COMMISSION

REGION I

,

.

50-334/90 05 i

'

Report Nos.

50-412/90-04 j

I 50 334 I'

Docket Nos.

50-412

DPR-66 License Nos. NPF+73

,

c-Licensee: Duquesne Light Company l

Post Office Box 4 l

,

l Shippinoport. Pennsylvania 15077-j facility Name: Beaver. Valley Power Station Units 1 & 2

Inspection At:. King of Prussia, Pennsylvania i

Inspection Conducted: January 29, 1990 i

i Inspector:

F'~8'

"-'

/- 5o-10

+

J. turia, Radiation Specialist, t.ffluents Radiation date r

Protection Section (ERPS)

W MD

!

. Approved By: E.

  • 1g res Unief ERP5, f acil1 Qts Radiological Safety date

p dSafeguards, Branch Inspection Summary:

Inspection on January 29, 1990 (Combined Inspection Report Nos. 50-334/90 05: 50712/90-04)

,

Areas Inspected:

Review of the circumstances surrounding the shipment of

.,

-scaffo13Tng to the Quadrex Recycle Center, Oak Ridge, Tennessee, on January 10, t

1990.

,

Results: Within the areas inspected, one violation was noted (Transportation).

.

k i

.

P 9002070388 900132

{DR ADOCK 05000334 PDC

.

-

-

.

.

-

-

l i

'

.

-

.

..

.

i

'

)

l DETAILS l

1.

Personnel Contacted H. Bicehouse, Radiation Protection Officer, Quadrex Recycle Center

-

J. Kosmal, Manager { Health Physics, Beaver Valley

,

P. Wilson, Residen Inspector

2.

Purpose l

The purpose of this inspection was to examine the circumstances surrounding the shipment of a SeaVan by the licensee to the Quadrex Recycle Center, Oak y

Ridge. Tennessee, Upon receipt of the SeaVan at Quadrex, two holes in the

,

side of the SeaVan, each approximately three square inches, were discovered.

,

3.

Chronology of Events On January 10,1990,- the licensee shipped eight steel drums and a SeaVan to

,

the Quadrex Recycle Center, Oak Ridge, Tennessee.. The SeaVan contained

'

contaminated scaffoldina material and was packaged as Radfonctive Material, Low SpeciTic Activity ((SA)lved at Quadrex, and durin

,

and was consigned as exclusive use.

-

On January 11 1990, the shipment arr receipt

!

inspection..ifwasdiscoveredthattwoholes,eachap three square inches in size were in the side of the SeaVan. proximate 1 Investig tion by Quadrex personnel revealed that a cart utilized to transport scaffolding rails was loose within the SeaVan, w;th the location and size of the holes consistent with the size and height above the SeaVan floor of an I-beam on the bottom of the cart. Wipe tests of the two holes and the I-beam failed t

to detect any removable contamination.

NRC regulations contained in'10 CFR 71.5 requires that licensees shipping

-

<

radioactive materials comply with the applicable regulations of the U. S.

Department of Transportation set forth in 49 CFR, 49 CFR 173.425 requires

-

that LSA shipments made exclusive use must be packaged in strong, tight containers so that there be no leakage of radioactive material during conditions normally incident to transportation.

The licensee's failure to.

adequately brace the cart containing contaminated scaffolding rails lead to a breach of package integrity, and could have led to the subsequent release of radioactive materials.

4.

E_xit-Interview

_

The inspector talked with Mr. J. Kosmal by telephone at the conclusion of the inspection on January 29, 1990. The inspector summarized the scope of the inspection and inspection findings.

..

.

.

. -