IR 05000321/1978040

From kanterella
Jump to navigation Jump to search
IE Insp Repts 50-321/78-40 & 50-366/78-49 on 781204-08. Noncompliance Noted:Deficiencies in QA Procedures & semi- Annual Surveys
ML19261B907
Person / Time
Site: Hatch  Southern Nuclear icon.png
Issue date: 01/02/1979
From: Cunningham A, Hufham J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML19261B893 List:
References
50-321-78-40, 50-366-78-49, NUDOCS 7903070525
Download: ML19261B907 (4)


Text

/jka #f Goq'o,

.

UNITED STATES

,

NUCLEAR REGULATORY COMMISSION

,

,

-

39, g

REGION 11

"

g 101 M ARIETTA STREET. N.W.

ATLANTA, GEORGIA 30303 o%, v /

.....

Report Nos..

50-321/78-40 and 50-366/78-49 Docket Nos.: 50-321 and 50-366 License Nos.:

DPR-57 and NPF-5 Licensee:

Georgia Power Company Facility Name: Edwin I. Hatch Nuclear Plant Units 1 and 2 Inspection at:

Environmental Center Decatur, Georgia 2030 Peachtree Street Atlanta, Georgia Edwin I. Hatch Units 1 and 2 Baxley, Georgia Inspection conducted: Dedember 4-8, 1978 Inspector:

A. L. Cunningt m I Reviewed by

.Ld s s nV i > l~\\ y

  • '

J.

Hufham, 01ie Date

.

Env onmental apd Special Projects Section Fue Facility add flaterials Safety Branch Inspection Summary Inspection on December 4-8, 1978 (Report Nos. 50-321/78-40 and 50-366/78-49)

Areas Inspected: Routine, unannounced inspection of nonradiological environ-mental protection including administrative controls; review of previous enforcement matters; a review of procedures; a review of biological surveil-lance program; review of special studies program; review of licensee event reports.

Inspection involved 32 inspector-hours onsite by one NRC inspector.

Results: Of the six areas inspected, two apparent items of noncompliance were identified in two areas (deficiency:

quality assurance procedures (321/78-40-01, 366/78-49-01) Details I paragraph 4.a. ; inf raction:

semi-annual Surveys (321/78-40-02, 366/78-49-02) Details I, paragraph 6).