May 12, 2004

SUBJECT:

PILGRIM NUCLEAR POWER STATION - NRC INTEGRATED INSPECTION REPORT 05000293/2004002.

Dear Mr. Balduzzi:

On March 31, 2004, the US Nuclear Regulatory Commission (NRC) completed an inspection at the Pilgrim Nuclear Power Station. The enclosed integrated inspection report documents the inspection findings, which were discussed on April 8, 2004, with you and members of your staff.

The inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license.

The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel.

This report documents two self-revealing findings of very low safety significance (Green) for which no violation of NRC requirements was identified. Additionally, licensee-identified violations which were determined to be of very low safety significance are listed in Section 4OA7 of this report. If you contest any NCV in this report, you should provide a response with the basis for your denial, within 30 days of the date of this inspection report, to the Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, D.C. 20555-0001; with copies to the Regional Administrator, Region I; the Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington, D.C. 20555-0001; and the NRC Resident Inspector at Pilgrim.

Since the terrorist attacks on September 11, 2001, NRC has issued five Orders and several threat advisories to licensees of commercial power reactors to strengthen licensee capabilities, improve security force readiness, and enhance controls over access authorization. In addition to applicable baseline inspections, the NRC issued Temporary Instruction 2515/148, "Inspection of Nuclear Reactor Safeguards Interim Compensatory Measures," and its subsequent revision, to audit and inspect licensee implementation of the interim compensatory measures required by order. Phase one of TI 2515/148 was completed at all commercial power nuclear power plants during calender year '02 and the remaining inspection activities for the Pilgrim Nuclear Power Station were completed in July 2003. The NRC will continue to monitor overall safeguards and security controls at the Pilgrim Nuclear Power Station.

Michael Balduzzi

In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and its enclosures, and your response (if any), will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of the NRCs document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Sincerely,

/RA/

A. Randolph Blough, Director Division of Reactor Projects Docket No.

50-293 License No.

DPR-35

Enclosure:

Inspection Report 05000293/2004002 w/Attachment: Supplemental Information

REGION I==

Docket No:

50-293 License No:

DPR-35 Report No:

05000293/2004002 Licensee:

Entergy Nuclear Operations, Inc.

Facility:

Pilgrim Nuclear Power Station Location:

600 Rocky Hill Road Plymouth, MA 02360 Inspection Period:

January 1-March 31, 2004 Inspectors:

W. Raymond, Senior Resident Inspector C. Welch, Resident Inspector J. McFadden, Health Physicist J. Talieri, Reactor Engineer S. McCarver, Reactor Engineer D. Silk, Emergency Preparedness Specialist (in-office)

Approved by:

Clifford Anderson, Chief Projects Branch 5 Division of Reactor Projects

Enclosure ii

SUMMARY OF FINDINGS

IR 05000293/2004002; 01/01/2004-03/31/2004; Pilgrim Nuclear Power Station; Personnel

Performance During Non-routine Plant Evolutions and Events; Post Maintenance Testing.

The report covered a 13-week period of inspection by resident inspectors and regional specialists in engineering and health physics. Two self-revealing Green findings were identified. The significance of most findings is indicated by their color (Green, White, Yellow,

Red) using Inspection Manual Chapter (IMC) 0609, Significance Determination Process (SDP). The NRCs program for overseeing the safe operation of commercial nuclear power reactors is described in NUREG-1649, Reactor Oversight Process, Revision 3, July 2000.

NRC-Identified and Self-Revealing Findings

Cornerstone: Initiating Events

Green.

A self-revealing finding of very low safety significance was identified because maintenance workers conducting trouble shooting did not adequately evaluate the potential consequence of installing an electrical insulating blanket over exposed relays.

This led to the inadvertent trip of a motor generator and plant transient on March 6, 2004.

The finding is greater than minor because it is associated with the human performance attribute of the initiating event cornerstone and adversely affects the cornerstone objective; it upset plant stability and caused a plant transient. The finding is of very low safety significance because the finding did not increase the likelihood of a primary or secondary loss of coolant accident, did not contribute to the likelihood of both a reactor trip and loss of mitigating equipment, and did not increase the frequency of a fire or flood. Additionally, the overpower condition remained within the safety analysis and was below the automatic reactor trip setpoint. No violation of regulatory requirements occurred A contributing cause of this finding relates to the cross-cutting area of human performance in that maintenance workers during trouble shooting activities did not adequately evaluate the possible consequence of installing an electrical insulating blanket over the exposed relays. (1R14)

Cornerstone: Mitigating Systems

Green.

A self-revealing finding of very low safety significance was identified because on December 5, 2003, plant personnel did not perform trouble shooting activities on a degraded residual heat removal system motor-operated valve (MO-1001-7D), in accordance with the stations trouble shooting procedure. Specifically, maintenance workers did not adequately consider potential latent failures and as a result did not adequately diagnose the extent of the valves degraded condition. During post maintenance testing, significant additional damage to the valves motor and associated thermal overload heaters occurred causing additional unnecessary unavailability for the D train of the residual heat removal system.

Summary of Findings (contd)

iv The finding is greater than minor because it is associated with the equipment performance attribute of the mitigating system cornerstone and adversely affects the cornerstone objective; it resulted in the valve being inoperable and unnecessarily increased the unavailability of the D train of the residual heat removal system. The finding is of very low safety significance because the residual heat removal systems safety functions were not lost and the D train was not inoperable for more than the Technical Specification allowed outage time. No violation of regulatory requirements occurred.

A contributing cause of the finding relates to the human performance cross-cutting area in that plant personnel conducting trouble shooting did not adequately consider potential latent failures during trouble shooting activities as prescribed in the stations trouble shooting procedure. (1R19)

Licensee Identified Violations

Violations of very low safety significance, which were identified by the Entergy, have been reviewed by the inspectors. Corrective actions taken or planned by Entergy have been entered into Entergys corrective action program. These violations and corrective action tracking numbers are listed in Section 4OA7 of this report.

REPORT DETAILS

Summary of Plant Status

Pilgrim Nuclear Power Station operated for the majority of the inspection period at 100 percent

(%) core thermal power, except for short periods of planned operation at reduced power for routine testing and maintenance.

An unplanned power change occurred the morning of March 6, 2004, while operating at 100%

power. Power increased to about 3.5% above the full power value after an inadvertent trip of a vital motor generator set caused an increase in the speed of the reactor recirculation pumps.

Control room operators reduced power to 95% within six minutes of the onset of the power increase.

A reduction in power to 50% commenced at 8:00 a.m. on March 22, 2004, to support thermal backwash of the main condenser and was followed by a planned outage to replace the pilot valves for safety relief valves RV-203-3A and 3D. The unit was removed from the electrical grid at 9:00 p.m. on March 22 and entered cold shutdown at 8:55 a.m. on March 23.

The reactor was taken critical at 10:15 p.m. on March 24 and the plant synchronized to the electrical grid at 11:05 a.m. on March 25. Full power, 2028 MWt, was obtained at 11:58 a.m.

on March 26. Minor power reductions for rod pattern adjustments occurred on March 26 and 27. Power was reduced to 50% on March 29 to establish the final target rod pattern and full power was reached on March 30 at 2:00 a.m..

REACTOR SAFETY

Cornerstones: Initiating Events, Mitigating Systems, and Barrier Integrity

1R01 Adverse Weather Protection

a.

Inspection Scope (2 samples)

The inspector performed walkdowns of plant systems during periods of extended cold weather during the weeks of January 12, 19, and 26, 2004. The inspector assessed Entergys cold weather preparations and verified that the cold conditions did not render key safety systems inoperable. The safety systems, structures, and components focused on during the inspection included the fire water storage tanks, the condensate tanks, the A and B emergency diesel generators, the station blackout diesel generator, and the salt service water pumps. Completed copies of station procedure 8.C.40, Cold Weather Surveillance, were reviewed. The Updated Final Safety Analysis Report section 10.9.3 and Table 10.9-1 Design Temperatures (Winter), were used as references during the inspection.

The inspector verified the EDG ventilation systems were aligned for winter operation and the ethylene glycol levels were greater than 40% as required in the winter lineup section of procedure 2.2.108, Diesel Generator Cooling and Ventilation System. The inspector reviewed the system health report and outstanding maintenance items for the heating ventilation and air conditioning (HVAC) system and discussed the systems overall health with the system engineer. The condition report (CR) database was searched for CRs associated with cold weather / freezing conditions for years 2001 through 2003 to verify Entergy was identifying cold weather related issues and had taken effective corrective actions. This inspection activity represented one sample of Entergys preparations for cold weather.

The inspector performed walkdowns of plant systems during periods of extreme cold weather on January 14, 15, 19, 20 and 26, 2004. The inspector assessed Entergys cold weather protection and verified that the cold conditions did not render key safety systems inoperable. The safety systems reviewed during the inspection included the emergency diesel generators, the salt service water pumps, and the facilities and components used in the emergency plan.

The inspector verified that Entergy was identifying cold weather related issues and had taken effective corrective actions (reference Condition Reports 20040110, 20040158,

===20040169). For the condition described in Condition Report 20040110, the inspector reviewed Entergys actions to address the effect of cold temperature on the public alert and notification system (PANS), along with the actions to implement compensatory measure and to restore the PANS to full operability. Following Entergys discovery on January 15, 2004, that 87 of the 112 emergency planning sirens were degraded, with the majority inoperable due to cold weather conditions, the inspectors verified that Entergy put into effect route alerting plans as a compensatory measure. Entergy restored all but two sirens to a fully functional status on January 19, with the two outstanding sirens disabled for unrelated reasons (car accident and road construction).

The PANS function became degraded when outside temperatures dropped below 8 degrees Fahrenheit because of a manufacturing error in the new siren controllers installed during the summer 2003. Other references used during this review are described in the attachment to this report. This inspection activity represented one sample of the protection of plant systems for specific cold weather related conditions.

b. Findings

No findings of significance were identified.

1R04 Equipment Alignment

1. Partial System Walkdowns

a. Inspection Scope

=

The inspector completed a partial review of risk significant plant systems during periods when the redundant system was out of service for scheduled preventive maintenance and testing. The inspectors reviewed plant procedures, system drawings and valve line-up procedures to walkdown and verify the correct system lineup. The Updated Final Safety Analysis Report and the Technical Specifications were reviewed to ascertain the required system configuration. The references used for this review are described in the attachment to this report. This inspection activity represented four samples.

  • A EDG System walkdown during B EDG Testing on February 24, 2004
  • RCIC System during the HPCI Outage on 2/25-27/04

b. Findings

No findings of significance were identified.

2. Full System Walkdown

a.

Inspection Scope (1 Sample)

The inspector performed a full system review of the reactor building closed cooling water (RBCCW) system. Proper alignment of key valves and breakers was verified by walkdown of accessible portions of the system and observation of main control board indications and plant computer information. Procedures 2.2.30, Reactor Building Closed Cooling Water (RBCCW) System, and 8.C.43, Monthly System Valve Lineup Surveillance, were reviewed along with plant drawing M215 P&ID Cooling Water System Reactor Building, to determine the required configuration. The Updated Final Safety Analysis Report (UFSAR), Technical Specifications, and system training manual were also reviewed.

The material condition of the RBCCW system was assessed through visual inspection of the accessible portions of the system, and a review of condition reports (January 2001-February 2004), outstanding maintenance requests, the fourth quarter 2003 system health report, maintenance rule information, and discussion with the system engineer.

The inspector sampled Entergys corrective action program records to verify that Entergy was identifying and correcting equipment alignment problems at an appropriate threshold.

b. Findings

No findings of significance were identified.

1R05 Fire Protection

1. Quarterly Fire Protection Inspection

a.

Inspection Scope (11 Samples)

The inspector toured selective areas of the plant to observe conditions related to: (1)transient combustibles and ignition sources;

(2) the material condition and readiness of fire protection systems and equipment; and
(3) the condition and status of readiness of fire barriers used to prevent fire damage or fire propagation. The inspector verified that any identified degraded conditions were compensated by compensatory measures until appropriate corrective actions could be taken. The inspector also reviewed the applicable fire hazard analysis fire zone data sheets and selective surveillance procedures to ensure that the specified fire suppression systems surveillance criteria were met. This inspection activity represented eleven samples.
  • Fire Zone 2.7, Turbine Lube Oil Reservoir
  • Fire Zone 2.5, Clean and Dirty Lube Oil Storage
  • Fire Zones 2.11, 2.11A, 2.12, 2.12A, comprising the 51 ft main turbine deck area
  • Fire Zone 1.11, Reactor Building 51 ft Elevation East
  • Fire Zone 1.12, Reactor Building 51 ft Elevation West
  • Fire Zone 2.3, A Battery Room Turbine Building 37 ft Elevation

b. Findings

No findings of significance were identified.

2. Annual Fire Drill Observation

a.

Inspection Scope (1 Sample)

The inspector monitored the performance of fire brigade training drills conducted on January 14, and March 3, 2004. The drills involved a simulated fire in the Technical Support Center diesel room (January 14) and the A station battery room (March 3). For the March 3 drill, the inspector observed fire brigade personnel performance, and verified that Entergys pre-planned drill scenario was followed and that the drill objectives were met. The inspector verified that proper protective clothing and breathing apparatus were donned, that sufficient fire fighting equipment was brought to the scene, and fire protection personnel entered the fire area in a controlled manner. The inspector also verified that adequate fire fighting equipment specified in procedure PNPS 5.5.2, Special Fire Procedure, was properly staged for the area.

b. Findings

No findings of significance were identified.

1R07 Heat Sink Performance

1. Bi-Annual Review

a. Inspection Scope

( 4 Samples)

The inspectors reviewed Entergys programs and processes to ensure that the system components listed below could perform their design functions as intended. This inspection activity represented four samples.



Reactor Building Component Cooling Water (RBCCW) Heat Exchangers (E-209A/B)

To ensure compatibility with commitments made in response to Generic Letter 89-13, "Service Water System Problems Affecting Safety Related Equipment," the inspectors reviewed Entergys inspection, cleaning, and performance monitoring methods and frequency. The inspectors compared surveillance test and inspection data to the established acceptance criteria to verify that the results were acceptable and that operation was consistent with design.

The inspectors reviewed Entergys methods for controlling biotic fouling, such as sodium hypochlorite injection and monitoring for mussel growth, to verify that they were implemented effectively. Additionally, the inspectors walked down the selected heat exchangers, the sodium hypochlorite system, the EDG rooms and the SSW system to assess the material condition of these areas.

The inspector also reviewed a sample of Condition Reports (CR) related to the selected systems. This review was done to ensure that Entergy was appropriately identifying, characterizing, and correcting problems related to these components.

b. Findings

No findings of significance were identified.

1R11 Licensed Operator Requalification

1.

Licensed Operator Requalification Training (1 sample)

The inspector observed the performance of a staff crew during a simulator exam on January 30, 2004. The exam was performed in accordance with Scenario SES-134.

The scenario involved operational transients and design basis events. The inspector verified that the crew met the training scenario objectives and performed the critical tasks. The inspector verified proper use of the system operating procedures and emergency operating procedures. The inspector observed Entergys actions to implement the emergency plan and to make event classifications and notifications. The inspector also verified that the post-scenario critique discussed any relevant lessons learned and that discrepancies were discussed with the crew to enhance future performance. The inspector observed the use of industry operating experience, and the consistency between the simulator and the plant control room.

b. Findings

No findings of significance were identified.

1R12 Maintenance Implementation

a.

Inspection Scope (3 samples)

The inspector reviewed the follow-up actions for selected system, structure, or component (SSC) issues and reviewed the performance history of these SSCs to assess the effectiveness of PNPSs maintenance activities. The inspector reviewed PNPSs problem identification and resolution actions for these issues in accordance with PNPSs procedures and the requirements of 10 CFR 50.65(a)(1) and (a)(2),

Requirements for Monitoring the Effectiveness of Maintenance. In addition, the inspector reviewed selected SSC classification, performance criteria and goals, the system health reports, and the corrective actions that were taken or planned to verify whether the actions were reasonable and appropriate. The inspector attended meetings and reviewed Entergys plans to address the 8 systems in maintenance rule a(1) status as of January 19, 2004. This inspection activity represented three samples:

  • Proper classification of equipment issues for the high pressure coolant injection (HPCI) system. The inspector reviewed Entergys actions regarding the ramp generator termination box, the overspeed trip device, the injection valve control power, the turbine trip valve and the use of incorrect performance criteria.

Additional references used in this review are listed in the attachment to this report. The inspector reviewed Entergys basis for placing the HPCI system in maintenance rule a(1) status during this period.

  • Proper classification of equipment issues for the reactor core isolation cooling (RCIC) system. Additional references used in this review are listed in the attachment to this report. The inspector reviewed Entergys basis for placing the RCIC system in maintenance rule a(2) status.
  • Proper classification of equipment issues for the reactor building closed cooling water (RBCCW) system. Additional references used in this review are listed in the attachment to this report. The inspector reviewed Entergys basis for placing the RBCCW system in maintenance rule a(1) status. This review covered one sample.

b. Findings

No findings of significance were identified.

1R13 Maintenance Risk Assessments and Emergent Work Evaluation

a.

Inspection Scope (6 Samples)

The inspector evaluated on-line risk management for planned and emergent work. The inspector reviewed maintenance risk evaluations, work schedules, recent corrective actions, and control room logs to verify that other concurrent planned and emergent maintenance or surveillance activities did not adversely effect the plant risk already incurred with the out of service components. The inspector verified that Entergy took the necessary steps to control work activities, took actions to minimize the probability of initiating events and maintained the functional capability of mitigating systems. The inspector assessed Pilgrims risk management actions during plant walkdowns. The inspector also discussed the risk management with maintenance, engineering and operations personnel as applicable for the activities. Other references used for the inspection are identified in the attachment to this report. This inspection activity represented six samples:

  • Planned maintenance activities the week of January 25, including an in-depth review for the elevated Yellow risk condition on Tuesday, January 27.

===04100606 (CR 200400391).

  • Emergent work on the HPCI Gland Seal Condensate Pump P-220 on February 26 per MR 04102939.
  • Planned maintenance activities the week of February 23, including an in-depth review for the elevated Yellow risk condition on February 25 and 26 for the planned HPCI outage (MRs 03116717, 02116212, P9800669, 03119413, 04100143).
  • Planned maintenance activities on Thursday, March 18, including review of established compensatory measures for the degraded condition of the electric fire pump.

b. Findings

No findings of significance were identified.

1R14 Personnel Performance During Non-routine Plant Evolutions and Events

a. Inspection Scope

=

The inspector responded to the site on March 6, 2004, in response to a transient that occurred at 10:22 a.m. following the inadvertent trip of the vital motor generator set.

The inspection focused on personnel performance and was accomplished through an interview of station personnel, observation of the work site and fact-finding meeting, and reviews of operator logs, plant computer information, alarm printouts, and station drawings and procedures. Operator response to the transient was compared to station procedures to determine if the response was appropriate to the event and in accordance with procedures and training. The plant equipment response was reviewed and verified acceptable or captured in the corrective action program. The inspector also observed portions of the control room activities to restore power to 100%. This inspection activity represented one sample.

On March 12, 2004, the inspector observed control room operators perform a dead bus transfer to restore vital bus Y-2 back to the vital motor generator set. This infrequently performed evolution was accomplished in accordance with Attachment 7 of procedure 2.2.16, 120/240V AC Vital Services Instrument Power Supply (Y-2 ). The inspector also observed just in-time training performed earlier that morning. The inspection focused on communications, command and control, and procedure adherence. This inspection activity represented one sample.

b. Findings

Introduction Green. A self-revealing finding of very low safety significance was identified because maintenance workers conducting trouble shooting did not adequately evaluate the potential consequence of installing an electrical insulating blanket over exposed relays.

This led to the inadvertent trip of a motor generator and plant transient on March 6, 2004.

Description During trouble shooting activities inside the vital motor generator (MG) control cabinet, plant personnel inadvertently tripped the MG causing a momentary loss of electrical power to vital bus Y-2, a plant transient, and a small power increase. This MG is not safety related. Reactor power increased to about 3.5% above full power. Control room operators immediately recognized the power increase and reduced power to 95% within 6 minutes of the onset of the overpower condition.

Maintenance workers did not adequately evaluate the potential to adversely effect exposed equipment mounted on the inner door of the control cabinet prior to the installation of a protective rubber insulating blanket. Trouble Shooting procedure 3.M.1-34, states in part that an important consideration prior to trouble shooting is identification of the possible undesirable consequences on the plant from the planned troubleshooting activities. Workers installed the insulating blanket after they noted that exposed capacitors mounted on the bottom of the inner door could potentially strike the backside of the outer door and short. The workers supported the blanket from the top of the inner door and allowed it to rest on the exposed relays mounted on the upper portion of the inner door. Prior to the use of the blanket, the workers did not consider the consequence of movement of the insulating blanket over the exposed relays.

Subsequent movement of the blanket during the maintenance activity applied a sufficient force on the under voltage relay wires, on which the blanket rested, to cause the contacts to open. As a result, the supply breaker to the AC motor tripped. Eighteen seconds later, the generator output breaker tripped and Y-2 momentarily de-energized before transferring to its backup power supply, bus B-15.

The drop in Y-2 voltage and frequency, as the motor-generator coast-down, adversely affected the two reactor recirculation pumps speed control circuits, which falsely sensed a decreasing pump speed with no corresponding change in demand signal. In response, the control circuits raised each recirculation pumps speed to match its demand signal, increasing core flow and reactor power to approximately 103.5%. When the generator output breaker tripped and Y-2 de-energized, the recirculation pump speed control circuits locked up preventing any further speed changes. Operators properly responded to the transient and lowered reactor power to 95% within 6 minutes of the onset of the overpower transient.

Analysis The finding is greater than minor because it is associated with the human performance attribute of the initiating event cornerstone and adversely affects the cornerstone objective; it upset plant stability and caused a plant transient. The finding, in phase one of the at power SDP, screened to Green under the initiating event cornerstone. The finding did not increase the likelihood of a primary or secondary loss of coolant accident, did not contribute to the likelihood of both a reactor trip and loss of mitigating equipment, and did not increase the frequency of a fire or flood. Additionally, the overpower condition remained within the safety analysis and was below the automatic reactor trip setpoint. FIN 05000293/2004002-01 Maintenance Workers Did Not Adequately Evaluate Use of an Electrical Insulating Blanket Over Exposed Relays A contributing cause of this finding relates to the cross-cutting area of human performance in that maintenance workers during trouble shooting activities did not adequately evaluate the possible consequence of installing an electrical insulating blanket over the exposed relays as prescribed in the stations trouble shooting procedure.

Enforcement No violation of regulatory requirements occurred. License condition 3.A, Maximum Power Level; states the facility may be operated at a steady state power level not to exceed 2028 MWt. On March 6, 2004, the facility operated for less than 6 minutes at approximately 2100 MWt, or roughly 103.5% of rated thermal power. This overpower condition constituted a transient condition, not steady state operation, was below the analyzed transient overpower condition, and was promptly and properly corrected by the operators within the time requirements of Technical Specification 3.11.D.

1R15 Operability Evaluations

a.

Inspection Scope (4 Samples)

The inspector reviewed selected operability determinations to assess the adequacy of the evaluations, the use and control of compensatory measures, compliance with the technical specifications, and the risk significance of the issues. The inspector used the technical specifications, Final Safety Analysis Report, associated Design Basis Documents and PNPS Procedures 1.3.34.5, Operability Evaluations, and ENN-OP-104, Operability Determinations, as references. This inspection activity represented four samples.

  • EE 04100767 for OE 03-022, RB Truck Lock Pass Door (CR 200301413)
  • REO and Engineering Evaluation dated 2/6/04 for D Service Water Pump Corrosion (CR 20040391)
  • OE for CR 200400742, Potential common cause failure of safety related pumps due to fouling of pump recirculation line flow orifices (NRC IN 2004-001).

b. Findings

No findings of significance were identified.

1R17 Permanent Plant Modifications

a.

Inspection Scope (1 sample)

The inspector selected a risk-significant plant modification package for review to verify that the design bases, licensing bases, and performance capability of the risk significant system had not been degraded through the modification. The modification selected for review was PDC 03-083, Control Room Beta Annunciator System Upgrade.

For the selected modification, the inspector reviewed the design inputs, assumptions, and validations to determine the design adequacy. In addition, the inspector reviewed the associated 10 CFR 50.59 safety evaluation to verify that the safety issue pertinent to the changes were properly resolved or adequately addressed. The inspector also reviewed:

(1) field implementation of the changes to the annunciator system logic cards, scanner cards and alarm controllers;
(2) post-modification functional testing to determine the readiness for operations; and,
(3) compensatory measures used during periods when the annunciators were not functional. The inspector reviewed the associated drawings to independently verify the changes and post-work test methods were appropriate. The inspector reviewed Entergys actions to disposition discrepancies identified during the modification (reference condition reports 20040783, 20040784, 20040785, 20040786 and

===20040792). The inspector walked-down portions of the modification in the control room and observed installation and testing activities in progress. The inspector monitored the performance of the annunciator system during periodic reviews of plant operations.

References used during this review as listed in the attachment to this report. This inspection activity represented one sample.

b. Findings

No findings of significance were identified.

1R19 Post-Maintenance Testing

a. Inspection Scope

=

The inspector reviewed post-maintenance test activities on risk significant systems to verify that the effect of the test on the plant had been evaluated adequately, test equipment was appropriate and controlled, the test was properly performed in accordance with procedures, the test data met the required acceptance criteria, and the test activity was adequate to verify system operability and functional capability following maintenance. The inspector verified that systems were properly restored following testing and that discrepancies were appropriately documented in the corrective action process.

References used for this review are listed in the attachment to this report. The inspection activity represented eleven samples of post-work testing.

  • MR 04100126, Raise SRV Alarm Setpoints to 230 degrees F, 01/26/04
  • MR 03120762, Jumper for Turbine Stop Valve Alarm Relay, 1/22/4
  • MR 04101562, Partial Repack of MSIV AO-203-2A
  • MR 03101432, RV-203-3D Remove/Replace valve to correct leakage
  • MR 03101431, RV-203-3A Remove/Replace valve to correct leakage
  • MR P9800859, MO-1001-43C EQ BKR PM
  • MR P9800895, MO-1001-7C EQ BKR PM

b. Findings

Introduction Green. A self-revealing finding of very low safety significance was identified because on December 5, 2003, plant personnel did not perform trouble shooting activities on a degraded residual heat removal system motor-operated valve (MO-1001-7D), in accordance with the stations trouble shooting procedure. Specifically, maintenance workers did not adequately consider potential latent failures and as a result did not adequately diagnose the extent of the valves degraded condition. During post maintenance testing, significant additional damage to the valves motor and associated thermal overload heaters occurred causing additional unnecessary unavailability for the D train of the residual heat removal system.

Description On December 1, 2003, during installation of the actuator cover for torus suction valve MO-1001-7D, maintenance workers unintentionally pinched a motor lead between the actuator housing and its cover plate. The damaged lead shorted to ground during subsequent valve operation on December 4 and energized main control board alarm "RHR B Valves Overload" a few seconds into the fifth valve stroke. Plant personnel conducted troubleshooting activities per 3.M.1-34, Generic Trouble Shooting and Maintenance Procedure, and identified the damaged motor lead, signs of arcing, and that the motor was in good condition. However, the trouble shooting was narrowly focused and did not adequately consider potential latent failures, as specified in 3.M.1-34, due to the known short. As a result, plant personnel did not identify that one of three thermal overload heaters located in the breaker cubicle had failed. On December 5, following repair of the damaged lead, maintenance workers conducted a post maintenance test. During the test the overload alarm was received almost immediately upon energizing the motor and the valve did not move. Entergys subsequent investigation found all three overload heaters and the motor had been damaged (CR200304424). Entergy completed the necessary repairs and restored the train to service on December 6. The additional unavailability from December 5 to December 6 could have been avoided had adequate troubleshooting been conducted on December 4 and 5.

Analysis The finding is greater than minor because it is associated with the equipment performance attribute of the mitigating system cornerstone and adversely affects the cornerstone objective; it resulted in the valve being inoperable and unnecessarily increased the unavailability of one train of the residual heat removal system. The finding, in phase one of the at power SDP, screened to Green under the mitigating system cornerstone. The RHR system safety functions were not lost and the D train was not inoperable for more than the allowed 7-day outage time. FIN 05000293/2004002-02 Plant Personnel Did Not Perform Adequate Trouble Shooting Activities on a Degraded Residual Heat Removal System Motor-Operated Valve.

A contributing cause of the finding relates to the human performance cross-cutting area in that plant personnel conducting trouble shooting did not adequately consider potential latent failures during trouble shooting activities as prescribed in the stations trouble shooting procedure.

Enforcement No violation of regulatory requirements occurred.

1R20 Refueling and Outage Activities

a.

Inspection Scope (1 Sample)

Review of Outage Plan The inspector reviewed the work scope and risk assessment for the planned outage conducted on March 22-26, 2004, to verify Entergy addressed the outages impact on defense-in-depth for the five shutdown critical safety functions; electrical power availability, inventory control, decay heat removal, reactivity control, and containment.

Compensatory measures established for the elevated Yellow risk condition due to reduced shutdown cooling capability during maintenance on salt service water valve 3834 were reviewed and verified on a sampling basis.

Monitoring of Shutdown Activities The inspector observed periods of Entergys action to shut the plant down in accordance with procedures 2.1.14, Station Power Changes, and 2.1.5, Controlled Shutdown from Power; and to place the plant in a cold shutdown condition. The inspector reviewed the reactor vessel cool down rate, recorded per 2.1.7, Vessel Heat up and cool down, to determine whether it was within technical specification requirements.

Reactor Coolant System Instrumentation & Decay Heat Removal Monitoring Periodic walkdowns of the main control boards were performed to assess operation of the residual heat removal system and to verify indicated plant parameters for reactor coolant level, temperature, and pressure.

Monitoring of Heatup and Startup Activities The inspector observed portions of the startup activities on March 24-26 and 29. The inspection was performed by periodic control room observations and reviews of operator logs, plant computer information, and station procedures 2.1.1, Startup from Shutdown and 2.1.14, Station Power Changes. Reactor vessel heatup data, recorded per 2.1.7, Vessel Heat up and cool down, was reviewed to verify whether it was within technical specification requirements. The brief and special test of the safety relief valve pilot valves, accomplished per 8.5.6.2, Special Test for ADS System Manual Opening of Relief Valves, were observed by the inspector.

b. Findings

No findings of significance were identified.

1R22 Surveillance Testing

a.

Inspection Scope (7 Samples)

The inspector reviewed and/or observed surveillance testing to verify that the test acceptance criteria was consistent with technical specifications, ASME Code inservice test requirements, and Updated Final Safety Analysis Report requirements, the test was performed in accordance with the written procedure, the test data was complete and met procedural requirements, and the system was properly returned to service following testing. The inspector observed pre-job briefs for the test activities. The inspection activity represented seven inspection samples:

  • 8.5.5.1, RCIC Pump Operability Flow Rate and Valve Test At Approximately 1000 psig, and 8.A.17, RCIC System Integrity Surveillance.
  • 8.5.5.4, RCIC Motor Operated Valve Quarterly Operability Test.
  • 8.5.1.1 Attachment 2B, Core Spray System Operability - Pump Quarterly and Biennial Comprehensive Flow Rate Tests and Valve Tests, (B pump).
  • 8.E.23.1, HPCI Turbine Speed Control Calibration, Attachments 2 and 4.
  • 8.5.6.2, Special Test for ADS System Manual Opening of Relief Valves.

b. Findings

No findings of significance were identified.

1R23 Temporary Plant Modifications

a.

Inspection Scope (3 samples)

The inspector reviewed two temporary modifications to verify that the licensing bases and performance capability of the associated risk significant systems had not been degraded through the modifications. The temporary modifications reviewed were:

  • Temporary Alteration 03-1-082 to reset the alarm from relay 5A-K10B which was affected by a problem with turbine stop valve limit switch SVOS-1A(5). The temporary modification provided for allowing alarms from any other turbine stop valve. The inspector also reviewed Entergys actions to address the issues described in Condition Report 200400241.
  • Temporary Alteration 04-01-002 to reconfigure the tailpipe temperature alarms for safety relief valves SRV-3A and SRV-3D. The temporary modification provided new alarm setpoints above the current tailpipe temperatures for the leaking valves to assure the operators are alerted to degrading leakage conditions.

The inspector reviewed the design and licensing basis assumptions and the administrative controls to determine the adequacy of the temporary modification. In addition, the inspector reviewed the associated safety evaluation screening to verify that the safety issue pertinent to the changes were properly addressed. The inspector also reviewed the post-installation testing plans to verify the tests would assure the affected components were ready for operations. The inspector reviewed the control room logs to verify that selected temporary modifications were properly recorded. The inspector reviewed condition reports (CRs) related to temporary modifications to verify that identified problems were appropriately resolved. Additional references used in this review are identified in the attachment to this report.

The inspector also reviewed the installation of Temporary Alteration 04-1-005, to disable the reactor feed pumps seal water/cooling water low flow trip. The temporary alteration was chosen as a sample because of its potential to initiate a plant transient. The temporary alteration lifted leads in the main control board per Attachment 8 of procedure 2.2.31.1, On-line Isolation of E-122A/E-122B TBCCW Heat Exchangers, to disable the low flow trip while maintaining the low flow alarm operational. The inspector reviewed the temporary alteration, applicable schematics, the maintenance risk assessment, the lifted lead and jumper log, and the alarm response procedure and verified placement of the temporary alteration tags.

b. Findings

No findings of significance were identified.

Cornerstone: Emergency Preparedness (EP)

EP4 Emergency Action Level and Emergency Plan Changes

a.

Inspection Scope (1 sample)

An in-office inspection that reviewed recent changes to emergency plan implementing procedures was conducted on February 18-23, 2004. A thorough review was conducted for documents related to the risk significant planning standards (RSPS) and a general review was completed for non-RSPS documents. The review verified the changes, satisfied the standards of 10 CFR 50.54(q), 10 CFR 50.47(b), the requirements of 10 CFR 50 Appendix E, the intent of NUREG-0654, "Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants" and that the changes did not decrease the effectiveness of the plan. However, these changes are subject to future NRC inspections to ensure that as a result of these changes the emergency plan continues to meet NRC regulations.

b. Findings

No findings of significance were identified.

EP6 Drill Evaluation

a. Inspection Scope

( 3 Samples)

The inspector observed portions of the February 5 and March 10, 2004, emergency planning drills to assess Entergys ability to identify and classify plant events in accordance with the Emergency Action Levels and complete the required notifications in a timely manner. Operator response, communications, and command and control in the simulator control room, technical support center and emergency operations facility were also assessed during periods of observation. The drill critique was reviewed to verify the Entergy was identifying areas for improvement. This inspection activity represented two samples.

The inspectors observed training of licensed operators on January 30, 2004, to evaluate the operators ability to properly classify plant events in accordance with the Emergency Action Levels and complete the required notifications for plant events. This inspection activity represented one sample.

The inspector also verified Entergy was identifying drill and emergency preparedness related deficiencies and addressing these issues in the corrective action process. The inspector reviewed Entergys actions for the following condition reports: 20040110 and

===20040818.

b. Findings

No findings of significance were identified.

RADIATION SAFETY

Cornerstone: Occupational Radiation Safety (OS)

2OS1 Access Control to Radiologically Significant Areas (71121.01)

a. Inspection Scope

=

The inspector reviewed radiological work activities and practices and procedural implementation during observations and tours of the facilities and inspected procedures, records, and other program documents to evaluate the effectiveness of Pilgrims access controls to radiologically significant areas. This inspection activity represents the completion of seven

(7) samples relative to this inspection area (i.e., inspection procedure sections 02.01, 02.03.a, b, c, and d, and 02.05.a and b) in partial fulfillment of the annual inspection requirements.

Inspection Planning (02.01)

The inspector verified that there were no Entergy Performance Indicator events for the Occupational Exposure Cornerstone which required follow-up.

Problem Identification and Resolution (02.03.a, b, c, and d)

During this week of inspection, the inspector reviewed Entergys self-assessment activities for any results related to the access control program since the last inspection.

The intent of this review was to determine if identified problems are entered into the corrective action program for resolution. The inspector also reviewed corrective action reports related to access controls and included in this review any high radiation area radiological events that have occurred since the last inspection in this area. The inspector discussed the corrective action reports with several members of the radiological protection staff to determine that the follow-up activities were being conducted in an effective and timely manner commensurate with their importance to safety and risk. The self-assessments, conducted since the last inspection, did not cover health physics access controls directly but one self-assessment did address the human performance aspect of this activity in the Radiation Protection Department. This self-assessment did address one type of deficiency identified in the corrective action reports. As noted above, there were no Entergy Performance Indicator events or Entergy documentation packages for the Occupational Exposure Cornerstone which required review.

High Risk Significant, High Dose Rate HRA and VHRA Controls (02.05.a and b)

During this week of inspection, the inspector met at various times with the Radiation Protection Manager and a Radiation Protection (RP) Specialist and discussed the controls and procedures for high-dose-rate high radiation areas (HRAs) and for very high radiation areas (VHRAs). The inspector reviewed the subject procedures (as listed in the List of Documents Reviewed section) to verify that the level of worker protection was adequate.

Related Activities On March 23 and 25, the inspector observed Radiologically-Controlled Area (RCA)entries and exits being made by radiation workers at the primary RCA access control point to verify compliance with requirements for RCA entry and exit, wearing of record dosimetry, and issuance and use of alarming electronic radiation dosimeters. The inspector toured various elevations in the reactor, auxiliary, and radioactive waste buildings inside the primary RCA to verify the adequacy of the radiological controls which were being implemented. The inspector reviewed observed work activities for compliance with the radiation work permit (RWP) requirements. During these observations and tours the inspector reviewed, for regulatory compliance, the posting, labeling, barricading, and level of radiological access control for locked high radiation areas (LHRAs), high radiation areas (HRAs), radiation and contamination areas, and radioactive material areas. In addition, on March 24, the inspector observed radiological controls being implemented in the drywell during a maintenance outage. Also, on March 25, the inspector examined satellite RCAs including the locations of the warehouse where the respiratory protection maintenance facility was located, the trash compaction facility, the low level radioactive waste storage facility, the retube building, and the off-gas retention building.

The inspector performed a selective examination of documents (as listed in the List of Documents Reviewed section) to evaluate the adequacy of radiological controls. The review in this area was against criteria contained in 10 CFR 19.12, 10 CFR 20 (Subparts D, F, G, H, I, and J), Technical Specifications, and procedures.

b. Findings

No findings of significance were identified.

2OS2 ALARA Planning and Controls (71121.02) a.

Inspection Scope (2 samples)

The inspector reviewed the effectiveness of Entergys program to maintain occupational radiation exposure as low as is reasonably achievable (ALARA). This inspection activity represents the completion of two

(2) samples relative to this inspection area (i.e.,

inspection procedure sections 02.01.a and 02.03.a) in partial fulfillment of the biennial inspection requirements.

Inspection Planning (02.01.a)

Prior to and during this inspection, the inspector reviewed pertinent information regarding plant collective exposure history, current exposure trends, and ongoing or planned activities in order to assess current performance and exposure challenges. The inspector determined the plants three-year rolling average collective exposure through the end of 2002. The inspector also reviewed the sites collective exposure for 2003 and the preliminary three-year rolling average collective exposure through the end of 2003.

Verification of Dose Estimates and Exposure Tracking Systems (02.03.a)

On March 23, the inspector met with an ALARA Specialist. During this meeting, the inspector reviewed the assumptions and basis for the current annual collective exposure estimate for 2004 for an anticipated year of normal operations with contingencies for emergent work. The inspector also reviewed the applicable ALARA procedures used to determine the methodology for estimating work activity-specific exposures and the intended dose outcome.

Related Activities Also, on March 23, the inspector discussed the ALARA activities in support of the current maintenance outage with an ALARA specialist. The inspector reviewed the pre-job reviews and estimates for the RWPs for this maintenance outage.

The inspector performed a selective examination of documents (as listed in the List of Documents Reviewed section) for regulatory compliance and for adequacy of control of radiation exposure. The review was against criteria contained in 10 CFR 20.1101 (Radiation protection programs), 10 CFR 20.1701 (Use of process or other engineering controls), and procedures.

b. Findings

No findings of significance were identified.

2OS3 Radiation Monitoring Instrumentation and Protective Equipment (71121.03)a.

Inspection Scope (1 sample)

The inspector reviewed the program for health physics instrumentation to determine the accuracy and operability of the instrumentation. This inspection activity represents the completion of one

(1) sample relative to this inspection area (i.e., inspection procedure section 02.04.a) in partial fulfillment of the biennial inspection requirements.

Problem Identification and Resolution (02.04.a)

The inspector reviewed Entergy self-assessments and Condition Reports since the last inspection in this area to focus on radiological incidents that involved personnel-contamination-monitor alarms due to personnel internal exposures. The reviewed documents did not identify any significant recordable internal exposures.

Related Activities The inspector performed a selective examination of documents (as listed in the List of Documents Reviewed section) for regulatory compliance and adequacy in this area. The review was against criteria contained in 10 CFR 20.1501, 10 CFR 20 Subpart H, Technical Specifications, and procedures.

b. Findings

No findings of significance were identified.

OTHER ACTIVITIES

[OA]

4OA1 Performance Indicator Verification

a.

Inspection Scope (3 samples)

The initiating event cornerstone performance indicator (PI) data for unplanned scrams per 7,000 critical hours; unplanned scrams with loss of normal heat removal; and unplanned power changes per 7,000 critical hours were reviewed to assess the completeness and accuracy of the reported information. Specifically, PI data for the year 2003 was reviewed and compared to information contained in NRC inspection reports, Licensee Event Reports, and the Pilgrim monthly operating reports. This inspection activity represented three samples.

b. Findings

No findings of significance were identified.

4OA2 Identification and Resolution of Problems

Reactor Safety Cornerstone

1. Routine Quarterly Review of Corrective Action Program Issues

a. Inspection Scope

As required by Inspection Procedure 71152, Identification and Resolution of Problems, the inspector performed a screening of each item entered into the Entergys corrective action program. This review was accomplished by reviewing printouts of each condition report, attending daily screening meetings and/or accessing Entergys database. The purpose of this review was to identify conditions such as repetitive equipment failures or human performance issues that might warrant additional follow-up.

The inspector noted an apparent trend over the past year with main control board alarms from safety related breaker thermal overloads. To ensure a more significant safety issue did not exist, the inspectors reviewed the related condition reports listed below, interviewed engineering personnel, and reviewed station drawings, design documents, and procedures.

  • CR 2003-01715 dated April 29, 2003; MO-1400-4A overload alarm came in during the fourth full stroke out of five.
  • CR 2003-01750 dated April 30, 2003; Received RHR A Valves overload Alarm while stroking MO-1001-43A closed from ALT shutdown panel, and related CR 2003-01774.
  • CR 2003-03281 dated August 28, 2003; HPCI overload came in while starting HPCI gland seal blower.
  • CR 2003-04424 dated December 4, 2003; During PWT of MO-1001-7D received overload alarm on the second open stroke.
  • CR 2004-00200 dated January 21, 2004; During PWT of MO-1001-7C received overload alarm on second stroke.

b. Findings

No findings of significance were identified.

Radiation Safety Cornerstone

2. Annual Sample of Corrective Action Program Issues

a.

Inspection Scope (1 sample)

The inspector selected ten issues identified in the Corrective Action Program (CAP) for detailed review (Condition Report Nos. CR-PNP-2003-03754, -03775, -03997, -04019, -

===04079, -04189, -04531, and -04672 and CR-PNP-2004-00899 and -00292). The issues were associated with the use of bubble suits for respiratory protection, allowable dose alarm set points, use of an unapproved radioactive material storage area, contaminated materials found in a clean area, a backlog of health physics instruments for repair, failure to follow an air sampling procedure, the calibration of a liquid radioactive waste process monitor, failure to update a radiological effluent program document, failure of an ion chamber instrument in the field, and failure to document a survey reading. The documented reports for the issues were reviewed to ensure that the full extent of the issues was identified, an appropriate evaluation was performed, and appropriate corrective actions were specified and prioritized.

b. Findings

No findings of significance were identified.

4OA3 Event Follow-up

1. Licensee Event Report Review and Closeout

=

a.

(Closed) LER 50-293/2003-005: HPCI and RCIC Inoperable due to De-energized Bus Caused by Breaker Malfunction. The inspector reviewed Entergys actions associated with Licensee Event Report (LER) 50-293/2003-005. Corrective actions were described in Condition Report 200303394. This event was also described in Section 4OA3 of NRC Report 2003-07. The LER provided an accurate description of the event and followup actions. The inspector noted that Entergys root cause and equipment failure evaluations had identified that the current transformer had failed causing the breaker to malfunction.

There had been no other similar failures noted at Pilgrim. This LER is closed.

4OA5 Other Activities

a. Inspection Scope

(2515/TI-154)

Temporary Instruction 2515/TI-154, Spent Fuel Material Control and Accounting at Nuclear Power Plants. Phase I and Phase II of the inspection was completed during this inspection period. Appropriate documentation was provided to NRC management as required.

b. Findings

No findings of significance were identified.

4OA6 Meetings, Including Exit

On April 8, 2004, the inspectors presented the inspection results to Mr. Michael Balduzzi, and other members of his staff. The inspectors confirmed that no proprietary information was provided or examined during the inspection.

4OA7 Licensee-Identified Violation

The following violations of very low safety significance (Green) were identified by Entergy and are violations of NRC requirements which meets the criteria of Section VI of the NRC Enforcement Policy, NUREG-1600, for being dispositioned as a Non-cited Violation.

  • 10 CFR 50.65 requires Entergy to monitor certain plant systems and to initiate appropriate corrective actions when system performance does not meet Entergy established goals. Contrary to the above, on January 19, 2004, Entergy determined that the high pressure coolant injection (HPCI) system had exceeded the Pilgrim Station Maintenance Rule program performance criteria for functional failures in August 2003, but no action had been taken to initiate the appropriate corrective actions because the wrong criteria had been in use to trend HPCI performance. This item was captured in CR 200400168.
  • Contrary to 10 CFR 50, Appendix B, Criterion XVI, Entergys actions were ineffective to prevent corrosion induced loss of wall thickness on the discharge pipes for the safety-related salt service water pumps. Specifically, Entergy identified in November 2000 that chronic wetting conditions and corrosion had caused loss of wall thickness on pipe spool piece JF29-15-9 on the discharge of the D salt service water pump. Subsequent actions and monitoring were ineffective to preclude continued exterior corrosion of the pipe spool piece, resulting in significant additional pipe wall loss as noted during maintenance activities in January 2004. This item was captured in CR 20040391.
  • Contrary to 10 CFR 50, Appendix B, Criterion XVI, on March 2, 2003, Entergy failed to enter into the corrective action program unexpected chemistry results obtained for the B train of reactor building closed cooling water. The results indicated a potential dilution event had occurred and were symptomatic of an ongoing leak. Investigation into CR 200400733, documenting additional degraded chemistry results on March 9, identified the B RBCCW loop had been inoperable for approximately 2 days (CR 200400818) as a result of system leakage through a maintenance boundary that exceeded allowable values. This item was captured in CR 200400818.

ATTACHMENT:

SUPPLEMENTAL INFORMATION

KEY POINTS OF CONTACT

Entergy personnel:

M. Balduzzi

Site Vice President

P. Dietrich

General Manager

E.Olson

Operations Manager

T. White

Director of Engineering

S. Bethay

Director Safety Assessment

V.Fallacara

Training Manager

G. Choquette Senior Engineer

D. Ellis

Licensing

J. Gaetdke

Senior Engineer

M. Gatslick

Licensing

P. Harizi

Senior Lead Engineer

J. Keene

Senior Engineer

P. Smalley

Senior HP/Chemistry Specialist

W. Coady

ALARA Specialist

R. Hartnett

Lead Radiation Protection Technician

P. Leavitt

Chemist

W. Lobo

Licensing Engineer

D. Perry

Radiation Protection Manager

R. Reilly

Chemist

T. Tetzlaff

Supervisor, Radiological Operations

G. Zavaski

Radiation Protection Specialist, Projects

LIST OF ITEMS

OPENED, CLOSED AND DISCUSSED

Opened and Closed

05000293/2004002-01 FIN Maintenance Workers Did Not Adequately Evaluate Use of an Electrical Insulating Blanket Over Exposed Relays
05000293/2004002-02 FIN Plant Personnel Did Not Perform Adequate Trouble Shooting Activities on a Degraded Residual Heat Removal System Motor-

Operated Valve.

Closed

05000293/2003-005 LER HPCI and RCIC Inoperable due to De-energized Bus Caused by Breaker Malfunction

LIST OF DOCUMENTS REVIEWED