IE Insp Repts 50-269/81-28,50-270/81-28 & 50-287/81-28 on 811105.Noncompliance Noted:Cask NLI-1/2 Delivered to Carrier for Transport Containing Approx 65 Gallons of Water, Contrary to Certificate of Compliance
ML15224A484
Person / Time
Site: Oconee  
Issue date: 11/24/1981
From: Collins T, Hosey C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML15224A480 List:
References
50-269-81-28, 50-270-81-28, 50-287-81-28, NUDOCS 8201270410
Download: ML15224A484 (3)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION REGION Il 101 MARIETTA ST., N.W., SUITE 3100 ATLANTA, GEORGIA 30303 Report Nos. 50-269/81-28, 50-270/81-28 and 50-287/81-28 Licensee:

Duke Power Company 422 South Church Street Charlotte, NC 28242 Facility Name:

Oconee Docket Nos. 50-269, 50-270 and 50-287 License Nos. DPR-38, DPR-47 and DPR-55 Inspection at Oconee site near Seneca, South Carolina Inspector-I'll_________________________

i42,&

1z4 tO I s :

H Cate Signed Approved y: A4t'*4$ I 4ilz4fst V M. Hosey, Acting Section Chief Date Signed

Technical Inspection Branch Engineering and Technical Insp'ection Division SUMMARY Inspection on November 5, 1981 Areas Inspected This routine, unannounced inspection involved 7.5 inspector-hours on site in the area of shipment of radioactive materia Results In the area inspected, one violation was foun Q,6

~~ODt{

REPORT DETAILS Persons Contacted Licensee Employees

  • J. Norman Pope, Superintendent of Operations W. Morgan, Shift Supervisor R. Bond, Licensing and Projects Engineer T. C. Matthews, Technical Specialist, Licensing J. A. Long, Health Physics Support Functions Coordinator NRC Resident Inspectors
  • W. T. Orders D. 0. Myers
  • Attended exit interview Exit Interview The in.spection scope and findings were summarized on November 5, 1981 with those persons indicated in paragraph 1 abov The inspector stated to licensee management that failure to meet the requirements of the Certifi cate of Compliance of spent fuel shipping cask certificate number USA/9010/

B(

)F, model number NLI-1/2, is a violation of 10 CFR 71.1 Plant manage ment acknowledged the inspector's finding.

Licensee Action on Previous Inspection Findings Not inspecte.

Unresolved Items Unresolved items were not identified during this inspectio.

Spent Fuel Shipment to McGuire Nuclear Station 10 CFR 71.12 requires that persons delivering licensed material to a car rier for transport in a package for which a certificate of compliance has been issued comply with the terms and conditions of the license, certifi cate or other approval. Certificate of compliance 9010, Revision 7 states that the NLI-1/2 shipping cask cavity and containment vessel (inner con tainer) shall have no free water when delivered to a carrier for transpor On November 3, 1981, licensee personnel at McGuire Station discovered while filling the spent fuel shipping cask that the cask cavity was partially full of water, approximately 65 gallon After investigation, it was deter mined that the vent (V-1)

and drain (V-2)

were not marked and that the hose

connection to the vent (V-1)

and drain (V-2)

valves were apparently reversed during the loading process at Oconee resulting in incomplete drainage of the cask cavity prior to shipment as required by Procedure No. OP/O/A/1510/10, Shipment of Spent Fuel Using NLI-1/2 cas The inspector stated that failure to dewater the cask prior to shipment was a violation of 10 CFR 71.12 (269/270/287/81-28-01).

On November 3, 1981, the licensee revised Procedure N OP/O/A/1510/10, Shipment of Spent Fuel Using NLI-1/2 Cask, stating that proper identifi cation of Vent (V-1) and Drain (V-2) valves on the shipping cask and proper identification of all hoses used in the operation will be initiate In addition, the procedure was revised for verification of each step of opera tion of Vent (V-1)

and Drain (V-2) to meet their intended requirement II