IR 05000250/1987025

From kanterella
Jump to navigation Jump to search
Partially Withheld Insp Repts 50-250/87-25 & 50-251/87-25 on 870511-15 (Ref 10CFR2.790(d) & 73.21).Violations Noted: Failure to Control Personnel & Equipment Access Into Containment & Inadequate Vehicle Search
ML17347A533
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 06/01/1987
From: Masnyk O, Mcguire D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML17347A532 List:
References
50-250-87-25, 50-251-87-25, NUDOCS 8706110032
Download: ML17347A533 (2)


Text

r p,S RE+II

'fp.0

<<sr*ad +

Report Nos.

50-250/87-25 SAFEGUARDS INFORMATIOII UNITED STATES NUCLEAR REGULATORY COMMISSION

REGION II

101 MARIETTASTREET, N.W.

ATLANTA,GEORGIA 30323 JUN 05 ~7 and 50-251/87-25 Licensee:

Florida Power and Light Company 9250 Mest Flaqler Street Miami, FL 33408 Docket Nos ~: 50-250 and 50-251 Faci Iity Name:

turkey Point Inspection (;onducted:

May 11-1b, 198/

License Nos.:

DPR-3l and OPR-41 inspector:

rys>a

.

asny, ys>ca ec

>

pec>a

>s Approved by:

i'.

c uvre, ie

,

ys>ca

" ecuri y ec ion Nuclear Materials Safety and feguards Branch Division of Radiation Safety nd Safeguards e

igne e

sgge SUMMARY t

Scope:

This routine, unannounced inspection involved a review of the following areas:

Security Plans and Procedures; Barriers - Protected and Vital Areas; Compensatory Measures; Detection Aids -

Protected and Vital Areas; Access Control of Personnel, Packages, and Vehicles; and Contingency Plan Implementation.

Results:

Two violations of regulatory requirements were identified:

Failure to control personnel and equipment access into Containment.

Inadequate vehicle search.

870b110032 870b03 PDR

>> ADOCK 05000250 SAFEGUARDS INFOR[v)AnPN

~ ~Ops'I" tgTcsv EirXOS:IP - '-" )'"'~".-108 5 ~

PAGE 1S I"'"'