Finding | |
|---|---|
| Title | Failure to Follow Procedure Results in Loss of Decay Heat Removal to the Spent Fuel Pool |
| Description | The inspectors reviewed a self-revealing non-cited violation of Technical Specifications 5.4.1(a), involving a loss of decay heat removal in the spent fuel pool due to station personnel failing to correctly follow operation of pool gate seal air supply procedure. On April 17, 2012, Grand Gulf Nuclear Station was preparing to drain the reactor cavity to reinstall the vessel head after the completion of refueling activities. In preparation, the upper containment pool to the reactor cavity gate was installed by General Electric-Hitachi technicians with Entergy oversight. Technicians were directed by procedure to verify that all supply isolation toggle valves to the gate seals were open and secured in place. However, technicians failed to complete this action correctly and the control room was informed that all prerequisites were completed and began the cavity drain down. The control room immediately noticed the fuel pool drain tank level was decreasing and attempted to makeup to the tank via the normal makeup valve. When the fuel pool drain tank level reached 17 percent full, both fuel pool cooling and cleanup pumps tripped as expected, resulting in loss of decay heat removal to the spent fuel pool. The main control room entered the off-normal event procedure for inadequate decay heat removal, and they secured the drain down evolution. Approximately 47 minutes later, spent fuel pool cooling was re-established. During this event, the spent fuel pool temperature did not exceed the limits required by Technical Requirements Manual Section 6.7.4 (140F). Short term corrective actions included restoring decay heat removal to the spent fuel pool and conducting a human performance review of the event. The licensee entered this issue into the corrective action program as Condition Report CR-GGN-2012-05756. The finding is more than minor because it is associated with the human performance attribute of the Barrier Integrity Cornerstone and adversely affects the cornerstone objective to provide reasonable assurance that physical design barriers protect the public from radionuclide releases caused by accidents or events. Using Inspection Manual Chapter 0609.04, Phase 1 - Initial Screening and Characterization of Findings, the inspectors determined that the finding was of very low safety significance (Green) because the finding only represented a loss of spent fuel pool cooling that would not preclude restoration of cooling to the spent fuel pool prior to pool boiling. This finding has a cross-cutting aspect in the area of human performance associated with the work practices component because licensee personnel failed to use adequate self- and peer-checking techniques to ensure gate seals were properly inflated prior to cavity drain down. |
| Site: | Grand Gulf |
|---|---|
| Report | IR 05000416/2012003 Section 1R20 |
| Date counted | Jun 30, 2012 (2012Q2) |
| Type: | NCV: Green |
| cornerstone | Barrier Integrity |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71111.2 |
| Inspectors (proximate) | R Smith A Barrett J Laughlin V Gaddy G Apger A Fairbanks B Rice J Braisted R Kumana |
| CCA | H.12, Avoid Complacency |
| INPO aspect | QA.4 |
| ' | |
Finding - Grand Gulf - IR 05000416/2012003 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Grand Gulf) @ 2012Q2
Self-Identified List (Grand Gulf)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||