05000416/FIN-2011005-01
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to Perform an Adequate Inspection of Probable Maximum Precipitation Door Seals Protecting Safety Related Equipment |
| Description | The inspectors identified a non-cited violation of 10 CFR 50 Appendix B, Criterion V, Instructions, Procedures, and Drawings, for failure to perform an adequate inspection of probable maximum precipitation door seals protecting safety related equipment. Inspectors found that one of the door seals to standby service water pump house A was in a degraded condition. The inspectors identified that the door seal did not make complete contact with the door frame all the way around. The licensee determined that the probable maximum precipitation seal for the identified door was in a degraded condition. Failure of this door seal during a probable maximum precipitation event could potentially cause flooding of the standby service water pump house A. Immediate corrective actions included the site initiating compensatory actions for the degraded seal by staging sand bags in the area and requiring monitoring of the affected door during heavy rainfall. The licensee entered this issue into the corrective action program as Condition Report CR-GGN-2011-07687. The finding is more than minor because it is associated with the protection against external factors attribute of Mitigating System Cornerstone and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. In Inspection Manual Chapter 0609.04, Phase 1 - Initial Screening and Characterization of Findings, the inspectors used the seismic, flooding, and severe weather Table 4b and determined that it would not affect multiple trains of safety equipment and that the finding had very low safety significance (Green). This finding has a cross-cutting aspect in the area of human performance associated with the resources component in that the licensees procedure used for the inspection of the door seals did not take into account the status of the pump house ventilation system while performing the door seal inspection, and therefore, the licensee failed to make the required adjustments to the door seals resulting in their inspections of the probable maximum precipitation door seals being inadequate. |
| Site: | Grand Gulf |
|---|---|
| Report | IR 05000416/2011005 Section 1R05 |
| Date counted | Dec 31, 2011 (2011Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.05 |
| Inspectors (proximate) | G Guerra P Elkmann R Smith W Sifre V Gaddy B Rice G Schlapper |
| CCA | H.7, Documentation |
| INPO aspect | WP.3 |
| ' | |
Finding - Grand Gulf - IR 05000416/2011005 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Grand Gulf) @ 2011Q4
Self-Identified List (Grand Gulf)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||