Finding | |
|---|---|
| Title | Inadequate Operability evaluation of the CCW Miscellaneous User Isolation Valves |
| Description | The team identified a Green non-cited violation of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, for the licensees failure to perform an adequate operability evaluation following the discovery that the component cooling water miscellaneous user isolation valves would not isolate the safety-related piping from the non-safety related portion. The licensee entered the issue into their corrective action program as condition report 823056. In 2013, the valve actuators were modified from air to open and close, to a spring to close design so this is not a current operability issue. The team determined that the failure to perform an adequate operability evaluation as required by NMP-AD-012, Operability Determinations and Functionality Assessments, was a performance deficiency. The performance deficiency was determined to be more than minor because it was associated with the Mitigating Systems cornerstone attribute of Equipment Performance and adversely affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the inspectors had reasonable doubt on the past operability of component cooling water because the operability evaluation relied on assumptions that were not correct, regarding the ability to establish make-up water to the on-service component cooling water train. The team performed a significance screening of this finding using the guidance provided in IMC 0609, Significance Determination Process, Attachment 0609.04, Initial Characterization of Findings. The team determined the finding required a detailed risk evaluation in accordance with Exhibit 2, "Mitigating Systems Screening Questions," and Exhibit 4, "External Event Screening Questions. A risk analysis was completed by a regional senior reactor analyst in accordance with the guidance of NRC IMC 0609 Appendix A. A bounding analysis was performed using Farley site specific seismic data and a conditional core damage probability determined using the NRC Farley SPAR PRA model. In addition, NUREG/CR6544 and NUREG/CR4550 show SSC fragility data for generic component types. From Table 1 Generic Seismic Fragilities the data shows that offsite power would be affected at 0.3G, electrical equipment and large flat bottomed storage tanks at approx. 1G, heat exchangers at 1.9 G with motor driven pumps at 2.0 G and piping at 3.8G. The major analysis assumptions included: a one year exposure period, no credit for the reactor coolant pump (RCP) shutdown seals, the performancedeficiency was assumed to result in lowering surge tank level and subsequent common cause failure of all three CCW pumps with no recovery, and the miscellaneous header piping and components were assumed to fail from a seismic event of magnitude 0.3 0.5 G. The dominant sequence was a loss of RCP seal cooling resulting in an RCP seal LOCA caused by loss of CCW. The risk was mitigated by the low frequency of the seismic initiating event. The analysis determined that the risk increase due to the performance deficiency was an increase in core damage frequency of < 1E-6/year, a GREEN finding of very low safety significance. The team did not identify a cross-cutting aspect associated with this finding because this performance deficiency was not indicative of present licensee performance. |
| Site: | Farley |
|---|---|
| Report | IR 05000348/2014007 Section 1R21 |
| Date counted | Jun 30, 2014 (2014Q2) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.21 |
| Inspectors (proximate) | D Mas E Stamm G Macdonald M Yeminy N Feliz Adorno R Nease S Kobylarz T Lighty |
| Violation of: | 10 CFR 50 Appendix B Criterion V |
| INPO aspect | |
| ' | |
Finding - Farley - IR 05000348/2014007 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Farley) @ 2014Q2
Self-Identified List (Farley)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||